Sample records for hplc-diode array detector

  1. Instrumentation: Photodiode Array Detectors in UV-VIS Spectroscopy. Part II.

    ERIC Educational Resources Information Center

    Jones, Dianna G.

    1985-01-01

    A previous part (Analytical Chemistry; v57 n9 p1057A) discussed the theoretical aspects of diode ultraviolet-visual (UV-VIS) spectroscopy. This part describes the applications of diode arrays in analytical chemistry, also considering spectroelectrochemistry, high performance liquid chromatography (HPLC), HPLC data processing, stopped flow, and…

  2. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  3. Simultaneous determination of bioactive constituents in Danggui Buxue Tang for quality control by HPLC coupled with a diode array detector, an evaporative light scattering detector and mass spectrometry.

    PubMed

    Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun

    2007-09-01

    Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.

  4. Single Lab Validation of a LC/UV/FLD/MS Method for Simultaneous Determination of Water-soluble Vitamins in Multi-Vitamin Dietary Supplements

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to develop a Single-Lab Validated Method using high-performance liquid chromatography (HPLC) with different detectors (diode array detector - DAD, fluorescence detector - FLD, and mass spectrometer - MS) for determination of seven B-complex vitamins (B1 - thiamin, B2 – ...

  5. Determination of flavonoids in plant material by HPLC with diode-array and electro-array detections.

    PubMed

    Mattila, P; Astola, J; Kumpulainen, J

    2000-12-01

    A high-performance liquid chromatographic (HPLC) method with in-line connected diode-array (DAD) and electro-array (EC) detection to identify and quantify 17 flavonoids in plant-derived foods is described. Catechins were extracted from the samples using ethyl acetate, and quantification of these compounds was performed with the EC detector. Other flavonoids were quantified with DAD after acid hydrolysis. The methods developed were effective for the determination of catechins and other flavonoids in plant-derived foods. Responses of the detection systems were linear within the range evaluated, 20-200 ng/injection (DAD) and 20-100 ng/injection (EC), with correlation coefficients exceeding 0.999. Coefficient of variation was under 10.5%, and recoveries of flavonoids ranged from 70 to 124%. Purity of the flavonoid peaks was confirmed by combining the spectral and voltammetric data.

  6. High-performance liquid chromatographic characterization of some medical plant extracts used in cosmetic formulas.

    PubMed

    Schulz, H; Albroscheit, G

    1988-06-17

    Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found.

  7. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

    PubMed

    Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J

    2013-06-30

    Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma

    PubMed Central

    Kopec, Rachel E.; Schweiggert, Ralf M.; Riedl, Ken M.; Carle, Reinhold; Schwartz, Steven J.

    2013-01-01

    Rationale Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. Methods After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. Results For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. Conclusions HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. PMID:23681818

  9. The Quorum-Sensing Regulon of Vibriofischeri: Novel Components of the Autoinducer/LuxR Regulatory Circuit

    DTIC Science & Technology

    1999-06-01

    cpdP, from the marine symbiotic bacterium Vibrio fische ri 160 Table of abbreviations 30C6-HSL AI-1 AI-2 C8-HSL CHAPS CNP EDTA FMN GFP HPLC ...using a Zorbax C18 1.0 mm by 150 mm reverse-phase column on a Hewlett-Packard 1090 HPLC /1040 diode array detector at the Harvard Microchemistry...separated by reversed-phase HPLC , and sequenced (Table 2; 10-PK12, 10-PK39, and 10-PK51). From two of the three peptide sequences (Materials and

  10. Profiling of components of rhizoma et radix polygoni cuspidati by high-performance liquid chromatography with ultraviolet diode-array detector and ion trap/time-of-flight mass spectrometric detection.

    PubMed

    Fu, Jinfeng; Wang, Min; Guo, Huimin; Tian, Yuan; Zhang, Zunjian; Song, Rui

    2015-01-01

    Rhizoma et Radix Polygoni Cuspidati (Huzhang in Chinese, HZ) is a traditional medicinal plant in China. Many of the components of HZ have been proved to be bioactive while it is difficult to conduct a comprehensive chemical profiling of HZ as a consequence of the absence of efficient separation system and sensitive detective means. We developed a simple and effective method for comprehensive characterization of constituents in HZ. To develop a simple and effective method to characterize the components in HZ and provide useful information for subsequent metabolic studies of HZ. The components in HZ aqueous extract were characterized by using high performance liquid chromatography with UV diode-array detector (HPLC-DAD) and ion trap/time-of-flight mass spectrometric detection (HPLC-IT/TOF). Stilbenes, anthraquinones, gallates and tannins, naphthalenes and some other compounds were identified and confirmed by diagnostic fragment ions with accurate mass measurements, characteristic fragmentation pathways and relevant published literatures. Among the 238 constituents detected in HZ, a total number of 74 constituents were identified unambiguously or tentatively, including 29 compounds reported for the first time in HZ. The identification and structure elucidation of these chemicals provided essential data for quality control and further in vivo metabolic studies of HZ. Key words: Polygonum cuspidatum, HPLC-DAD, HPLC-IT/TOF, qualitative analysis.

  11. Online extraction-high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry for rapid flavonoid profiling of Fructus aurantii immaturus.

    PubMed

    Tong, Runna; Peng, Mijun; Tong, Chaoying; Guo, Keke; Shi, Shuyun

    2018-03-01

    Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction for Fructus aurantii immaturus (Zhishi), OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of eighteen flavonoids were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and compound 9, natsudaidain-3-O-glucoside, was discovered in Zhishi for the first time. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2018. Published by Elsevier B.V.

  12. High Performance Liquid Chromatography-Diode Array Detector Method for the Simultaneous Determination of Five Compounds in the Pulp and Seed of Sea Buckthorn.

    PubMed

    Zhao, Lu; Wen, E; Upur, Halmuart; Tian, Shuge

    2017-01-01

    Sea buckthorn ( Hippophae rhamnoides L.) as a traditional Chinese medicinal plant has various uses in Xinjiang. A reversed-phase rapid-resolution liquid-chromatography method with diode array detector was developed for simultaneous determination of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the pulp and seed of sea buckthorn, a widely used traditional Chinese medicine for promoting metabolism and treating scurvy and other diseases. Compounds were separated on an Agilent ZORBAX SB-C18 column (4.6 mm × 250 mm, 5 μm; USA) with gradient elution using methanol and 0.4% phosphoric acid (v/v) at 1.0 mL/min. Detection wavelength was set at 280 nm. The fruits of wild sea buckthorn were collected from Wushi County in Aksu, Xinjiang Province. The RSD of precision test of the five compounds were in the range of 0.60-2.22%, and the average recoveries ranged from 97.36% to 101.19%. Good linearity between specific chromatographic peak and component qualities were observed in the investigated ranges for all the analytes ( R 2 > 0.9997). The proposed method was successfully applied to determine the levels of five active components in sea buckthorn samples from Aksu in Xinjiang. The proposed method is simple, fast, sensitive, accurate, and suitable for quantitative assessment of the pulp and seed of sea buckthorn. Quantitative analysis method of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the extract of sea buckthorn pulp and seed is developed by high-performance liquid chromatography (HPLC) diode array detection.This method is simple and accurate; has strong specificity, good precision, and high recovery rate; and provides a reliable basis for further development of the substances in the pulp and seed of sea buckthorn.The method is widely used for content determination of active ingredients or physiologically active components in traditional Chinese medicine and its preparation Abbreviation used: PR: protocatechuic acid, RU: rutin, QU: quercetin, KA: kaempferol, IS: isorhamnetin, HPLC: high-performance liquid chromatography, HPLC-DAD: high performance liquid chromatographydiode array detector, LOD: linearity and limit of detection, LOQ: limit of quantitation, RSD: relative standard deviation.

  13. Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector

    PubMed Central

    Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won

    2015-01-01

    Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746

  14. High-speed counter-current chromatography coupled online to high performance liquid chromatography-diode array detector-mass spectrometry for purification, analysis and identification of target compounds from natural products.

    PubMed

    Liang, Xuejuan; Zhang, Yuping; Chen, Wei; Cai, Ping; Zhang, Shuihan; Chen, Xiaoqin; Shi, Shuyun

    2015-03-13

    A challenge in coupling high-speed counter-current chromatography (HSCCC) online with high performance liquid chromatography (HPLC) for purity analysis was their time incompatibility. Consequently, HSCCC-HPLC was conducted by either controlling HPLC analysis time and HSCCC flow rate or using stop-and-go scheme. For natural products containing compounds with a wide range of polarities, the former would optimize experimental conditions, while the latter required more time. Here, a novel HSCCC-HPLC-diode array detector-mass spectrometry (HSCCC-HPLC-DAD-MS) was developed for undisrupted purification, analysis and identification of multi-compounds from natural products. Two six-port injection valves and a six-port switching valve were used as interface for collecting key HSCCC effluents alternatively for HPLC-DAD-MS analysis and identification. The ethyl acetate extract of Malus doumeri was performed on the hyphenated system to verify its efficacy. Five main flavonoids, 3-hydroxyphloridzin (1), phloridzin (2), 4',6'-dihydroxyhydrochalcone-2'-O-β-D-glucopyranoside (3, first found in M. doumeri), phloretin (4), and chrysin (5), were purified with purities over 99% by extrusion elution and/or stepwise elution mode in two-step HSCCC, and 25mM ammonium acetate solution was selected instead of water to depress emulsification in the first HSCCC. The online system shortened manipulation time largely compared with off-line analysis procedure and stop-and-go scheme. The results indicated that the present method could serve as a simple, rapid and effective way to achieve target compounds with high purity from natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Shikimic Acid Monitoring by HPLC with Diode Array Detector in Citrus sinensis Orchard with Glyphosate

    USDA-ARS?s Scientific Manuscript database

    This study was conducted to evaluate the effect of weed control with glyphosate on shikimic acid levels in citrus, “Pêra” cultivar. The experimental plots were set in Santo Antônio de Posse county, Sao Paulo State, Brazil with the following treatments: glyphosate at 1,440 g.ha-1 a.e. between citrus ...

  16. Validated HPLC-Diode Array Detector Method for Simultaneous Evaluation of Six Quality Markers in Coffee.

    PubMed

    Gant, Anastasia; Leyva, Vanessa E; Gonzalez, Ana E; Maruenda, Helena

    2015-01-01

    Nicotinic acid, N-methylpyridinium ion, and trigonelline are well studied nutritional biomarkers present in coffee, and they are indicators of thermal decomposition during roasting. However, no method is yet available for their simultaneous determination. This paper describes a rapid and validated HPLC-diode array detector method for the simultaneous quantitation of caffeine, trigonelline, nicotinic acid, N-methylpyridinium ion, 5-caffeoylquinic acid, and 5-hydroxymethyl furfural that is applicable to three coffee matrixes: green, roasted, and instant. Baseline separation among all compounds was achieved in 30 min using a phenyl-hexyl RP column (250×4.6 mm, 5 μm particle size), 0.3% aqueous formic buffer (pH 2.4)-methanol mobile phase at a flow rate of 1 mL/min, and a column temperature at 30°C. The method showed good linear correlation (r2>0.9985), precision (less than 3.9%), sensitivity (LOD=0.023-0.237 μg/mL; LOQ=0.069-0.711 μg/mL), and recovery (84-102%) for all compounds. This simplified method is amenable for a more complete routine evaluation of coffee in industry.

  17. Analysis and improved characterization of minor antioxidants from leaves of Malus doumeri using a combination of major constituents' knockout with high-performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Zhao, Huading; Hu, Xin; Chen, Xiaoqin; Shi, Shuyun; Jiang, Xinyu; Liang, Xuejuan; Chen, Wei; Zhang, Shuihan

    2015-06-12

    Due to the complexity of natural products, efficient identification of bioactive compounds, especially for minor compounds, would require a huge effort. Here, we developed an effective strategy based on combining major constituents' knockout with high-performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) to comprehensively identify minor antioxidants in Malus doumeri, one of the longest known and most used tonic plant in Taiwan. First, five major compounds (I-V) in M. doumeri were knocked out by two-step stepwise high-speed countercurrent chromatography (HSCCC). Second, minor antioxidants were screened by 1,1-diphenyl-2-picrylhydrazyl radical-HPLC (DPPH-HPLC) assay. Third, structures of thirty minor antioxidants, including 11 dihydrochalcones, 4 flavanones, 3 flavonols, 2 flavones, 3 aurones and 7 phenolic acids, were unambiguously or tentatively identified by matching their characteristic UV spectra, accurate mass signals and key diagnostic fragment ions with standards or previously reported compounds. Twenty-six of them, as far as was known, were discovered from M. doumeri for the first time. The results indicated that the proposed method was a useful approach to explore minor bioactive compounds from complex natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Quantitative Analysis and Comparison of Four Major Flavonol Glycosides in the Leaves of Toona sinensis (A. Juss.) Roemer (Chinese Toon) from Various Origins by High-Performance Liquid Chromatography-Diode Array Detector and Hierarchical Clustering Analysis

    PubMed Central

    Sun, Xiaoxiang; Zhang, Liting; Cao, Yaqi; Gu, Qinying; Yang, Huan; Tam, James P.

    2016-01-01

    Background: Toona sinensis (A. Juss.) Roemer is an endemic species of Toona genus native to Asian area. Its dried leaves are applied in the treatment of many diseases; however, few investigations have been reported for the quantitative analysis and comparison of major bioactive flavonol glycosides in the leaves harvested from various origins. Objective: To quantitatively analyze four major flavonol glycosides including rutinoside, quercetin-3-O-β-D-glucoside, quercetin-3-O-α-L-rhamnoside, and kaempferol-3-O-α-L-rhamnoside in the leaves from different production sites and classify them according to the content of these glycosides. Materials and Methods: A high-performance liquid chromatography-diode array detector (HPLC-DAD) method for their simultaneous determination was developed and validated for linearity, precision, accuracy, stability, and repeatability. Moreover, the method established was then employed to explore the difference in the content of these four glycosides in raw materials. Finally, a hierarchical clustering analysis was performed to classify 11 voucher specimens. Results: The separation was performed on a Waters XBridge Shield RP18 column (150 mm × 4.6 mm, 3.5 μm) kept at 35°C, and acetonitrile and H2O containing 0.30% trifluoroacetic acid as mobile phase was driven at 1.0 mL/min during the analysis. Ten microliters of solution were injected and 254 nm was selected to monitor the separation. A strong linear relationship between the peak area and concentration of four analytes was observed. And, the method was also validated to be repeatable, stable, precise, and accurate. Conclusion: An efficient and reliable HPLC-DAD method was established and applied in the assays for the samples from 11 origins successfully. Moreover, the content of those flavonol glycosides varied much among different batches, and the flavonoids could be considered as biomarkers to control the quality of Chinese Toon. SUMMARY Four major flavonol glycosides in the leaves of Toona sinensis were determined by HPLC-DAD and their contents were compared among various origins by HCA. Abbreviations used: HPLC-DAD: High-performance liquid chromatography-diode array detector, HCA: Hierarchical clustering analysis, MS: Mass spectrometry, RSD: Relative standard deviation. PMID:27279719

  19. High Performance Liquid Chromatography-Diode Array Detector Method for the Simultaneous Determination of Five Compounds in the Pulp and Seed of Sea Buckthorn

    PubMed Central

    Zhao, Lu; Wen, E; Upur, Halmuart; Tian, Shuge

    2017-01-01

    Context: Sea buckthorn (Hippophae rhamnoides L.) as a traditional Chinese medicinal plant has various uses in Xinjiang. Objective: A reversed-phase rapid-resolution liquid-chromatography method with diode array detector was developed for simultaneous determination of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the pulp and seed of sea buckthorn, a widely used traditional Chinese medicine for promoting metabolism and treating scurvy and other diseases. Settings and design: Compounds were separated on an Agilent ZORBAX SB-C18 column (4.6 mm × 250 mm, 5 μm; USA) with gradient elution using methanol and 0.4% phosphoric acid (v/v) at 1.0 mL/min. Detection wavelength was set at 280 nm. Materials and Methods: The fruits of wild sea buckthorn were collected from Wushi County in Aksu, Xinjiang Province. Statistical performances: The RSD of precision test of the five compounds were in the range of 0.60-2.22%, and the average recoveries ranged from 97.36% to 101.19%. Good linearity between specific chromatographic peak and component qualities were observed in the investigated ranges for all the analytes (R2 > 0.9997). Results: The proposed method was successfully applied to determine the levels of five active components in sea buckthorn samples from Aksu in Xinjiang. Conclusions: The proposed method is simple, fast, sensitive, accurate, and suitable for quantitative assessment of the pulp and seed of sea buckthorn. SUMMARY Quantitative analysis method of protocatechuic acid, rutin, quercetin, kaempferol, and isorhamnetin in the extract of sea buckthorn pulp and seed is developed by high-performance liquid chromatography (HPLC) diode array detection.This method is simple and accurate; has strong specificity, good precision, and high recovery rate; and provides a reliable basis for further development of the substances in the pulp and seed of sea buckthorn.The method is widely used for content determination of active ingredients or physiologically active components in traditional Chinese medicine and its preparation Abbreviation used: PR: protocatechuic acid, RU: rutin, QU: quercetin, KA: kaempferol, IS: isorhamnetin, HPLC: high-performance liquid chromatography, HPLC-DAD: high performance liquid chromatographydiode array detector, LOD: linearity and limit of detection, LOQ: limit of quantitation, RSD: relative standard deviation PMID:28216897

  20. Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector.

    PubMed

    Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen

    2012-07-01

    A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.

    PubMed

    Patyra, E; Kowalczyk, E; Grelik, A; Przeniosło-Siwczyńska, M; Kwiatek, K

    2015-01-01

    A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30°C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCα), detection capacity (CCβ), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 μg/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.

  2. Integration of magnetic solid phase fishing and off-line two-dimensional high-performance liquid chromatography-diode array detector-mass spectrometry for screening and identification of human serum albumin binders from Radix Astragali.

    PubMed

    Zhang, Yuping; Nie, Mingkun; Shi, Shuyun; You, Qingping; Guo, Junfang; Liu, Liangliang

    2014-03-01

    Radix Astragali is one of the most popular traditional medicinal herb and healthy dietary supplement. Isoflavonoids and astragalosides are the main bioactive ingredients. However, the systematic bioactive component analysis is inadequate so far. Then a facile method based on Fe3O4@SiO2-human serum albumin (Fe3O4@SiO2-HSA) magnetic solid phase fishing integrated with two-dimensional high-performance liquid chromatography-diode array detector-mass spectrometry (2D HPLC-DAD-MS(n)) was developed to fish out and identify HSA binders from Radix Astragali. The immobilized HSA displayed a high stability with 96.2% retained after ten consecutive cycles. 2D HPLC system (size exclusion chromatography×reversed phase chromatography, SEC×RP) were developed and optimised. Forty-seven bioactive compounds including thirty-four isoflavonoids and thirteen astragalosides were screened and identified or tentatively deduced based on their retention time, ultraviolet (UV), accurate molecular weight and diagnostic fragment ions. The results indicated that the integrated method could be widely applied for systematical fishing and identification of bioactive compounds, especially for low-abundance and overlapped compounds, from complex mixtures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Ionic liquid-based microwave-assisted extraction for the determination of flavonoid glycosides in pigeon pea leaves by high-performance liquid chromatography-diode array detector with pentafluorophenyl column.

    PubMed

    Wei, Wei; Fu, Yu-jie; Zu, Yuan-gang; Wang, Wei; Luo, Meng; Zhao, Chun-jian; Li, Chun-ying; Zhang, Lin; Wei, Zuo-fu

    2012-11-01

    In this study, an ionic liquid-based microwave-assisted extraction (ILMAE) followed by high-performance liquid chromatography-diode array detector with a pentafluorophenyl column for the extraction and quantification of eight flavonoid glycosides in pigeon pea leaves is described. Compared with conventional extraction methods, ILMAE is a more effective and environment friendly method for the extraction of nature compounds from herbal plants. Nine different types of ionic liquids with different cations and anions were investigated. The results suggested that varying the anion and cation had significant effects on the extraction of flavonoid glycosides, and 1.0 M 1-butyl-3-methylimidazolium bromide ([C4MIM]Br) solution was selected as solvent. In addition, the extraction procedures were also optimized using a series of single-factor experiments. The optimum parameters were obtained as follows: extraction temperature 60°C, liquid-solid ratio 20:1 mL/g and extraction time 13 min. Moreover, an HPLC method using pentafluorophenyl column was established and validated. Good linearity was observed with the regression coefficients (r(2)) more than 0.999. The limit of detection (LODs) (S/N = 3) and limit of quantification (LOQs) (S/N = 10) for the components were less than 0.41 and 1.47 μg/mL, respectively. The inter- and intraday precisions that were used to evaluate the reproducibility and relative standard deviation (RSD) values were less than 4.57%. The recoveries were between 97.26 and 102.69%. The method was successfully used for the analysis of samples of pigeon pea leaves. In conclusion, the developed ILMAE-HPLC-diode array detector using pentafluorophenyl column method can be applied for quality control of pigeon pea leaves and related medicinal products. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Simultaneous determination of chromones and coumarins in Radix Saposhnikoviae by high performance liquid chromatography with diode array and tandem mass detectors.

    PubMed

    Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom

    2011-09-16

    Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Antimicrobial activity of Marcetia DC species (Melastomataceae) and analysis of its flavonoids by reverse phase-high performance liquid chromatography coupled-diode array detector.

    PubMed

    Leite, Tonny Cley Campos; de Sena, Amanda Reges; Dos Santos Silva, Tânia Regina; Dos Santos, Andrea Karla Almeida; Uetanabaro, Ana Paula Trovatti; Branco, Alexsandro

    2012-07-01

    Marcetia genera currently comprises 29 species, with approximately 90% inhabiting Bahia (Brazil), and most are endemic to the highlands of the Chapada Diamantina (Bahia). Among the species, only M. taxifolia (A.St.-Hil.) DC. populates Brazil (state of Roraima to Paraná) and also Venezuela, Colombia, and Guyana. This work evaluated the antimicrobial activity of hexane, ethyl acetate, and methanol extracts of three species of Marcetia (Marcetia canescens Naud., M. macrophylla Wurdack, and M. taxifolia A.StHil) against several microorganism. In addition, the flavonoids were analyzed in extracts by HPLC-DAD. The tests were made using Gram-positive (three strains of Staphylococcus aureus) and Gram-negative (two strains of Escherichia coli, a strain of Pseudomonas aeruginosa and another of Salmonella choleraesius) bacteria resistant and nonresistant to antibiotics and yeasts (two strains of Candida albicans and one of C. parapsilosis) by the disk diffusion method. Solid-phase extraction (SPE) was performed on the above extracts to isolate flavonoids, which were subsequently analyzed by high performance liquid chromatography coupled diode array detector (HPLC-DAD). Results showed that extracts inhibited the Gram-positive bacteria and yeast. The hexane extracts possessed the lowest activity, while the ethyl acetate and methanolic extracts were more active. Marcetia taxifolia was more effective (active against 10 microorganisms studied), and only its methanol extract inhibited Gram-negative bacteria (P. aeruginosa and S. choleraesius). SPE and HPLC-DAD analysis showed that M. canescens and M. macrophylla contain glycosylated flavonoids, while the majority of extracts from M. taxifolia were aglycone flavonoids.

  6. Quality evaluation of Radix Astragali through a simultaneous determination of six major active isoflavonoids and four main saponins by high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors.

    PubMed

    Qi, Lian-Wen; Yu, Qing-Tao; Li, Ping; Li, Song-Lin; Wang, Yu-Xia; Sheng, Liang-Hong; Yi, Ling

    2006-11-17

    A method, high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors (HPLC-DAD-ELSD), was developed to evaluate the quality of Radix Astragali through a simultaneous determination of six major active isoflavonoids and four main saponins. The wavelength at 280 nm was chosen to determine six isoflavonoids: calycosin-7-O-beta-D-glucoside (1), ononin (2), (6alphaR, 11alphaR)-9,10-dimethoxypterocarpan-3-O-beta-D-glucoside (3), (3R)-2'-hydroxy-3',4'-dimethoxyisoflavan-7-O-beta-D-glucoside (4), calycosin (5), and formononetin (6); and ELSD connected after DAD was employed to determine four saponins: astragaloside IV (7), astragaloside II (8), astragaloside I (9), and acetylastragaloside I (10). This assay was fully validated with respect to precision, repeatability and accuracy. The proposed method was successfully applied to quantify the ten components in eleven samples from different localities in China; significant variations were demonstrated in the content of these compounds in the samples from different areas. This simple, rapid, low-cost and reliable HPLC-DAD-ELSD method is suitable for routine quantitative analysis and quality control of traditional Chinese medicines (TCMs) consisting of bioactive multi-components with different structures such as Radix Astragali.

  7. Development and validation of carbofuran and 3-hydroxycarbofuran analysis by high-pressure liquid chromatography with diode array detector (HPLC-DAD) for forensic Veterinary Medicine.

    PubMed

    Gonçalves, Vagner; Hazarbassanov, Nicolle Queiroz; de Siqueira, Adriana; Florio, Jorge Camilo; Ciscato, Claudia Helena Pastor; Maiorka, Paulo Cesar; Fukushima, André Rinaldi; de Souza Spinosa, Helenice

    2017-10-15

    Agricultural pesticides used with the criminal intent to intoxicate domestic and wild animals are a serious concern in Veterinary Medicine. In order to identify the pesticide carbofuran and its metabolite 3- hydroxycarbofuran in animals suspected of exogenous intoxication a high pressure liquid chromatography with diode array detector (HPLC-DAD) method was developed and validated in stomach contents, liver, vitreous humor and blood. The method was evaluated using biological samples from seven different animal species. The following parameters of analytical validation were evaluated: linearity, precision, accuracy, selectivity, recovery and matrix effect. The method was linear at the range of 6.25-100μg/mL and the correlation coefficient (r 2 ) values were >0.9811 for all matrices. The precision and accuracy of the method was determined by coefficient of variation (CV) and the relative standard deviation error (RSE), and both were less than 15%. Recovery ranged from 74.29 to 100.1% for carbofuran and from 64.72 to 100.61% for 3-hydroxycarbofuran. There were no significant interfering peaks or matrix effects. This method was suitable for detecting 25 positive cases for carbofuran amongst a total of 64 animal samples suspected of poisoning brought to the Toxicology Diagnostic Laboratory, School of Veterinary Medicine and Animal Sciences, University of Sao Paulo. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Noncontact Characterization of PV Detector Arrays

    DTIC Science & Technology

    1990-06-01

    11-7 3 III DIODE ARRAY AS A SAW CONVOLVER/STORAGE CORRELATOR .... III-1 III.A NONLINEAR ( VARACTOR ) ACTION OF THE DIODES .......................... I...associated with the diodes in the detector array. The varactor action of the diodes produces a voltage across the diodes which is pro- portional to the...type of interactions desired herein. An alternative approach is to em- ploy thin dielectric overlays, such as zinc oxide or silicon nitride

  9. Identification of cardiac glycosides in fractions from Periploca forrestii by high-performance liquid chromatography/diode-array detection/electrospray ionization multi-stage tandem mass spectrometry and liquid chromatography/nuclear magnetic resonance.

    PubMed

    Li, Yong; Wu, Xianfu; Li, Jianbei; Wang, Yinghong; Yu, Shishan; Lv, Haining; Qu, Jing; Abliz, Zeper; Liu, Jing; Liu, Yuanyan; Du, Dan

    2010-02-01

    Cardiac glycosides are a class of naturally occurring compounds that are characterized by some interesting biological activities and are widely distributed in the plant kingdom and can also be found in some animals. There is an interest in the chemical characterization of these molecules due to their toxicity and their use in medicines. In the study reported here, a combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography equipped with diode-array detector (HPLC-DAD/ESI-MS(n)), and hyphenation to both liquid chromatography and nuclear magnetic resonance spectroscopy (HPLC/NMR) were utilized for the on-line analyses of cardiac glycosides from Periploca forrestii. The fragmentation patterns and (1)H NMR spectra of nine isolated cardiac glycosides were investigated; their fragmentation rules and (1)H NMR spectral characteristics were summarized and applied to the structural identification of similar constituents in fractions from P. forrestii. As a result, a total of nine trace cardiac glycosides were tentatively determined by analyses of accurate molecular masses, representative fragment ions and characteristic (1)H NMR signals provided by HPLC/high-resolution mass spectrometry (HRMS), HPLC-DAD/ESI-MS(n) and HPLC/(1)H NMR experiments, respectively. Of these, eight (2-9) are new compounds and one (1) is reported from P. forrestii for the first time. Results of the present study can benefit the rapid identification and targeted isolation of new cardiac glycosides from crude plant extracts. 2009 Elsevier B.V. All rights reserved.

  10. Rapid and simple method for the determination of emodin in tartary buckwheat (Fagopyrum tataricum) by high-performance liquid chromatography coupled to a diode array detector.

    PubMed

    Peng, Lian-Xin; Wang, Jing-Bo; Hu, Li-Xue; Zhao, Jiang-Lin; Xiang, Da-Bing; Zou, Liang; Zhao, Gang

    2013-01-30

    A simple and rapid method for determining emodin, an active factor presented in tartary buckwheat (Fagopyrum tataricum), by high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) has been developed. Emodin was separated from an extract of buckwheat on a Kromasil-ODS C(18) (250 mm × 4.6 mm × 5 μm) column. The separation is achieved within 15 min on the ODS column. Emodin can be quantified using an external standard method detecting at 436 nm. Good linearity is obtained with a correlation coefficient exceeding 0.9992. The limit of detection and the limit of quantification are 5.7 and 19 μg/L, respectively. This method shows good reproducibility for the quantification of the emodin with a relative standard deviation value of 4.3%. Under optimized extraction conditions, the recovery of emodin was calculated as >90%. The validated method is successfully applied to quantify the emodin in tartary buckwheat and its products.

  11. Simultaneous quantification of eight bioactive components of Houttuynia cordata and related Saururaceae medicinal plants by on-line high performance liquid chromatography-diode array detector-electrospray mass spectrometry.

    PubMed

    Meng, Jiang; Leung, Kelvin Sze-Yin; Dong, Xiao-Ping; Zhou, Yi-Sheng; Jiang, Zhi-Hong; Zhao, Zhong-Zhen

    2009-12-01

    An on-line high performance liquid chromatography (HPLC)-diode array detector (DAD)-electrospray ionization mass spectrometry (ESI-MS) method has been developed to quantify simultaneously eight bioactive chemical components in Houttuynia cordata Thunb and related Saururaceae medicinal plants. Simultaneous separation of these eight compounds was achieved on a C(18) analytical column with gradient elution of acetonitrile and 0.2% acetic acid (v/v) at a flow rate of 0.6 mL/min and being detected at 280 nm. These eight compounds were completely separated within 90 min. Good linear regression relationship (r(2)>0.9978) within test ranges was shown in all calibration curves. Good repeatabilty for the quantification of these eight compounds in H.cordata was also demonstrated in this method, with intra- and inter-day variations less than 3.0%. The method established was successfully applied to quantify eight bioactive compounds in closely related species of H.cordata, which provides a new basis for quality assessment of H.cordata.

  12. Analysis of Organic Acids, Deacetyl Asperulosidic Acid and Polyphenolic Compounds as a Potential Tool for Characterization of Noni (Morinda citrifolia) Products.

    PubMed

    Bittová, Miroslava; Hladůkova, Dita; Roblová, Vendula; Krácmar, Stanislav; Kubán, Petr; Kubán, Vlastimil

    2015-11-01

    Organic acids, deacetyl asperulosidic acid (DAA) and polyphenolic compounds in various noni (Morinda citrifolia L.) products (4 juices, 4 dry fruit powders and 2 capsules with dry fruit powder) were analyzed. Reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a variable wavelength detector (VWD) and electrospray ionization time-of-flight mass spectrometer (ESI-TOF MS) was applied for simultaneous analysis of organic acids (malic, lactic, citric and succinic acid) and DAA. An RP-HPLC method with diode-array detector (DAD) was developed for the analysis of polyphenolic compound content (rutin, catechin, quercitrin, kaempferol, gallic acid, caffeic acid and p-coumaric acid). The developed methods can contribute to better characterization of available noni products that is required from the consumers. In our study, we discovered significant dissimilarities in the content of DAA, citric acid and several phenolic compounds in some samples.

  13. Simultaneous qualitative and quantitative determination of phenolic compounds in Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight and high performance liquid chromatography-diode array detector.

    PubMed

    Wu, Xiaofang; Ding, Wenjing; Zhong, Jiasheng; Wan, Jinzhi; Xie, Zhiyong

    2013-06-01

    An effective and comprehensive method was developed for the simultaneous analysis of phenolic compounds in the dried exudate of Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight (LCMS-IT-TOF) and high performance liquid chromatography-diode array detector (HPLC-DAD). Qualitative analysis of all the compounds presented in A. barbadensis Mill was performed on LCMS-IT-TOF, and the diagnostic fragmentation patterns of different types of phenolic compounds (chromones, phenyl pyrones, naphthalene derivative, anthrones and anthraquinones) were discussed on the basis of ESI-IT-TOF MS of components in A. barbadensis Mill and eleven authentic standards. Under the optimal HPLC-DAD chromatographic conditions, quantification of 11 typical phenolic compounds in 15 batches of A. barbadensis Mill was achieved on an Agilent TC-C18 column using gradient elution with a solvent system of methanol and water at a flow rate of 1.0mLmin(-1) and detected at 230nm. All calibration curves exhibited good linear relationship (r(2)>0.9991). The relative standard deviation values for intraday precision were less than 2% with accuracies between 98.21% and 104.57%. The recoveries of the eleven analytes ranged from 97.53 to 105.00% with RSDs less than 2%. This is the first simultaneous characterization and quantitative determination of multiple phenolic compounds in A. barbadensis Mill from locally grown cultivars in China by LCMS-IT-TOF and HPLC-DAD, which can be applied to standardize the quality of A. barbadensis Mill and the future design of nutraceutical and cosmetic preparations. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Sensitive characterization of polyphenolic antioxidants in Polygonatum odoratum by selective solid phase extraction and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Hu, Xin; Zhao, Huading; Shi, Shuyun; Li, Hui; Zhou, Xiaoling; Jiao, Feipeng; Jiang, Xinyu; Peng, Dongming; Chen, Xiaoqin

    2015-08-10

    The complexity of natural products always leads to the co-elution of interfering compounds with bioactive compounds, which then has a detrimental effect on structural elucidation. Here, a new method, based on selective solid phase extraction combined with 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) spiking and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS), is described for sensitive screening, selective extraction and identification of polyphenolic antioxidants in Polygonatum odoratum. First, 25 polyphenolic antioxidants (1-25) were screened by DPPH spiking with HPLC. Second, polydopamine coated Fe3O4 microspheres (Fe3O4@PDA) were prepared to selectively extract target antioxidants with extraction efficiency from 55% to 100% when the amount of Fe3O4@PDA, extraction time, desorption solvent and time were 10mg, 20 min, acetonitrile, and 5 min. Third, 25 antioxidants (10 cinnamides and 15 homoisoflavanones) were identified by HPLC-DAD-QTOF-MS/MS. Furthermore, the DPPH scavenging activities of purified compounds (IC50, 1.6-32.8 μg/mL) validated the method. Among the identified antioxidants, four of them (12, 13, 18 and 19) were new compounds, four of them (2, 4, 8 and 14) were first obtained from family Liliaceae, five of them (1, 3, 5, 7 and 9) were first reported in genus Polygonatum, while one compound (24) was first identified in this species. The results indicated that the proposed method was an efficient and sensitive approach to explore polyphenolic antioxidants from complex natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Antimicrobial activity of Marcetia DC species (Melastomataceae) and analysis of its flavonoids by reverse phase-high performance liquid chromatography coupled-diode array detector

    PubMed Central

    Leite, Tonny Cley Campos; de Sena, Amanda Reges; dos Santos Silva, Tânia Regina; dos Santos, Andrea Karla Almeida; Uetanabaro, Ana Paula Trovatti; Branco, Alexsandro

    2012-01-01

    Background: Marcetia genera currently comprises 29 species, with approximately 90% inhabiting Bahia (Brazil), and most are endemic to the highlands of the Chapada Diamantina (Bahia). Among the species, only M. taxifolia (A.St.-Hil.) DC. populates Brazil (state of Roraima to Paraná) and also Venezuela, Colombia, and Guyana. Objective: This work evaluated the antimicrobial activity of hexane, ethyl acetate, and methanol extracts of three species of Marcetia (Marcetia canescens Naud., M. macrophylla Wurdack, and M. taxifolia A.StHil) against several microorganism. In addition, the flavonoids were analyzed in extracts by HPLC-DAD. Materials and methods: The tests were made using Gram-positive (three strains of Staphylococcus aureus) and Gram-negative (two strains of Escherichia coli, a strain of Pseudomonas aeruginosa and another of Salmonella choleraesius) bacteria resistant and nonresistant to antibiotics and yeasts (two strains of Candida albicans and one of C. parapsilosis) by the disk diffusion method. Solid-phase extraction (SPE) was performed on the above extracts to isolate flavonoids, which were subsequently analyzed by high performance liquid chromatography coupled diode array detector (HPLC-DAD). Results: Results showed that extracts inhibited the Gram-positive bacteria and yeast. The hexane extracts possessed the lowest activity, while the ethyl acetate and methanolic extracts were more active. Conclusion: Marcetia taxifolia was more effective (active against 10 microorganisms studied), and only its methanol extract inhibited Gram-negative bacteria (P. aeruginosa and S. choleraesius). SPE and HPLC-DAD analysis showed that M. canescens and M. macrophylla contain glycosylated flavonoids, while the majority of extracts from M. taxifolia were aglycone flavonoids. PMID:23060695

  16. G-index: A new metric to describe dynamic refractive index effects in HPLC absorbance detection.

    PubMed

    Kraiczek, Karsten G; Rozing, Gerard P; Zengerle, Roland

    2018-09-01

    High performance liquid chromatography (HPLC) with a solvent gradient and absorbance detection is one of the most widely used methods in analytical chemistry. The observed absorbance baseline is affected by the changes in the refractive index (RI) of the mobile phase. Near the limited of detection, this complicates peak quantitation. The general aspects of these RI-induced apparent absorbance effects are discussed. Two different detectors with fundamentally different optics and flow cell concepts, a variable-wavelength detector equipped with a conventional flow cell and a diode-array detector equipped with a liquid core waveguide flow cell, are compared with respect to their RI behavior. A simple method to separate static - partly unavoidable - RI effects from dynamic RI effects is presented. It is shown that the dynamic RI behavior of an absorbance detector can be well described using a single, relatively easy-to-determine metric called the G-index. The G-index is typically in the order of a few seconds and its sign depends on the optical flow cell concept. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Simultaneous determination of 11 bioactive compounds in Jaeumganghwa-tang by high performance liquid chromatography-diode array detection

    PubMed Central

    Yun, Bo-Ra; Weon, Jin Bae; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Background: Jaeumganghwa-tang (JEGH) is a traditional Korean herbal medicine for the treatment of chronic bronchitis, nephritis and diabetes mellitus. Objective: A high performance liquid chromatography-diode array detector (HPLC-DAD) method was developed for simultaneous determination of 11 major compounds such as 5- hydroxymethylfurfural, mangiferin, paeoniflorin, nodakenin, naringin, hesperidin, decursinol, berberine, glycyrrhizin, atractylenolide III and decursin, in JEGH. Materials and Methods: The separation was conducted on Shishedo C18 column with gradient elution of 0.1% trifluoroacetic acid–acetonitrile. Detection of wavelength was set at 205, 250, 280 and 330 nm. Results: The developed analysis showed a good linearity (R2 >0.9997). The range of limit of detection and limit of quantification were observed from 0.04 to 0.43 and from 0.11 to 1.30, respectively. The intra- and inter-day test relative standard deviations (RSD) were less than 3% and the accuracy was 95.98-108.44%. The recoveries were between 92.75% and 109.19% and RSD range of recoveries was measured from 0.52% to 2.78%. Conclusion: This HPLC-DAD method can be successfully applied for simultaneous determination of 11 major compounds in JEGH samples. PMID:24991100

  18. Detection, characterization and identification of crucifer phytoalexins using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Pedras, M Soledade C; Adio, Adewale M; Suchy, Mojmir; Okinyo, Denis P O; Zheng, Qing-An; Jha, Mukund; Sarwar, Mohammed G

    2006-11-10

    We have analyzed 23 crucifer phytoalexins (e.g. brassinin, dioxibrassinin, cyclobrassinin, brassicanals A and C) by HPLC with diode array detection and electrospray ionization mass spectrometry (HPLC-DAD-ESI-MS) using both negative and positive ion modes. Positive ion mode ESI-MS appeared more sensitive than negative ion mode ESI-MS in detecting this group of compounds. A new HPLC separation method, new LC-MS and LC-MS(2) data and proposed fragmentation pathways, LC retention times, and UV spectra for selected compounds are reported.

  19. Characterization of Compounds in Psoralea corylifolia Using High-Performance Liquid Chromatography Diode Array Detection, Time-of-Flight Mass Spectrometry and Quadrupole Ion Trap Mass Spectrometry.

    PubMed

    Tan, Guangguo; Yang, Tiehong; Miao, Huayan; Chen, Hao; Chai, Yifeng; Wu, Hong

    2015-10-01

    High-performance liquid chromatography with diode array detection (HPLC-DAD), time-of-flight mass spectrometry (HPLC-TOFMS) and quadrupole ion trap mass spectrometry (HPLC-QITMS) were used for separation and identification of multi-components in Psoralea corylifolia. Benefiting from combining the accurate mass measurement of HPLC-TOFMS to generate elemental compositions, the complementary multilevel structural information provided by HPLC-QITMS and the characteristic UV spectra obtained from HPLC-DAD, 24 components in P. corylifolia were identified. The five groups of isomers were differentiated based on the fragmentation behaviors in QITMS and UV spectra. It can be concluded that an effective method based on the combination of HPLC-DAD, HPLC-TOFMS and HPLC-QITMS for identification of chemical components in P. corylifolia was established. The results provide essential data for further pharmacological and clinical studies of P. corylifolia and facilitate the rapid quality control of the crude drug. © Crown copyright 2015.

  20. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    PubMed

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  1. Simultaneous identification/determination system for phentolamine and sildenafil as adulterants in soft drinks advertising roborant nutrition.

    PubMed

    Mikami, Eiichi; Ohno, Tsutomu; Matsumoto, Hiroshi

    2002-12-04

    An easily available, simultaneous identification/determination procedure for phentolamine (PHE) and sildenafil (SIL) in adulterated dietary supplements was established by using a combination of three different analytical methods; thin-layer chromatography (TLC), liquid chromatography-mass spectrometry (LC/MS) and a high-performance liquid chromatography (HPLC)/photo-diode-array. The sample solution for TLC was applied to silica gel 60 F(254) plates with chloroform/ammonia solution (28)/methanol (70:5:3, lower layer) and chloroform/diethylamine/methanol (15:3:2) as the developing solvent. Spots were located under UV radiation at 254 nm. Mass spectra of PHE and SIL by LC/MS were investigated with electrospray ionization (ESI) interface, under both positive and negative ion mode. The HPLC analysis was performed on a column of Wakosil 5C18 (4.6 mm x 150 mm, 5 microm) with water/methanol/acetonitrile/triethylamine (580:250:170:1) adjusted with phosphoric acid to pH 3.0 as the mobile phase, and the effluent was monitored with a photo-diode-array detector. Quantitative HPLC analysis of PHE and SIL were detected at 280 nm. When this procedure was applied to commercial soft drinks, PHE and SIL were identified and determined at a concentration of 17 mg PHE and 44 mg SIL per bottle, respectively. The procedure described here is available for the screening of PHE and SIL in adulterated supplements. Copyright 2002 Elsevier Science Ireland Ltd.

  2. A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.

    PubMed

    Niu, Tian-Zeng; Zhang, Yu-Wei; Bao, Yong-Li; Wu, Yin; Yu, Chun-Lei; Sun, Lu-Guo; Yi, Jing-Wen; Huang, Yan-Xin; Li, Yu-Xin

    2013-03-25

    A reversed phase high performance liquid chromatography method coupled with a diode array detector (HPLC-DAD) was developed for the first time for the simultaneous determination of 9 flavonoids in Senecio cannabifolius, a traditional Chinese medicinal herb. Agilent Zorbax SB-C18 column was used at room temperature and the mobile phase was a mixture of acetonitrile and 0.5% formic acid (v/v) in water in the gradient elution mode at a flow-rate of 1.0mlmin(-1), detected at 360nm. Validation of this method was performed to verify the linearity, precision, limits of detection and quantification, intra- and inter-day variabilities, reproducibility and recovery. The calibration curves showed good linearities (R(2)>0.9995) within the test ranges. The relative standard deviation (RSD) of the method was less than 3.0% for intra- and inter-day assays. The samples were stable for at least 96h, and the average recoveries were between 90.6% and 102.5%. High sensitivity was demonstrated with detection limits of 0.028-0.085μg/ml for flavonoids. The newly established HPLC method represents a powerful technique for the quality assurance of S. cannabifolius. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Simple and rapid high-performance liquid chromatographic method for the determination of aspartame and its metabolites in foods.

    PubMed

    Gibbs, B F; Alli, I; Mulligan, C N

    1996-02-23

    A method for the determination of aspartame (N-L-alpha-aspartyl-L-phenylalanine methyl ester) and its metabolites, applicable on a routine quality assurance basis, is described. Liquid samples (diet Coke, 7-Up, Pepsi, etc.) were injected directly onto a mini-cartridge reversed-phase column on a high-performance liquid chromatographic system, whereas solid samples (Equal, hot chocolate powder, pudding, etc.) were extracted with water. Optimising chromatographic conditions resulted in resolved components of interest within 12 min. The by-products were confirmed by mass spectrometry. Although the method was developed on a two-pump HPLC system fitted with a diode-array detector, it is straightforward and can be transformed to the simplest HPLC configuration. Using a single-piston pump (with damper), a fixed-wavelength detector and a recorder/integrator, the degradation of products can be monitored as they decompose. The results obtained were in harmony with previously reported tedious methods. The method is simple, rapid, quantitative and does not involve complex, hazardous or toxic chemistry.

  4. Detection, characterization and identification of phenolic acids in Danshen using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An

    2007-08-17

    By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.

  5. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    PubMed Central

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  6. Evaluation of phenolic compounds in virgin olive oil by direct injection in high-performance liquid chromatography with fluorometric detection.

    PubMed

    Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco

    2006-04-19

    Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.

  7. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    PubMed

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  8. Characterisation of nucleosides and nucleobases in Mactra veneriformis by high performance liquid chromatography coupled with diode array detector-mass spectrometry (HPLC-DAD-MS).

    PubMed

    Liu, Rui; Ji, Jing; Wang, Lingchong; Chen, Shiyong; Guo, Sheng; Wu, Hao

    2012-11-15

    Mactra veneriformis has been used as sea food and traditional Chinese medicine (TCM) for thousands of years in China. In the present study, a high performance liquid chromatograph coupled with photodiode array detector and electrospray ionisation-mass spectrometer (HPLC-DAD-ESI-MS) method was established for detection of the nucleosides and nucleobases in M. veneriformis from four aquaticultural area of Jiangsu during different harvest time of one year. The validated method was successfully applied to identifying 10 nucleosides and nucleobases in 48 M. veneriformis samples. Quantitative analysis showed that nucleosides and nucleobases are rich in all M. veneriformis samples. However, their contents vary in different areas and harvest times. Principal component analysis (PCA) was used to classify the 48 samples based on the contents of the nucleosides and nucleobases. As a result, the samples could be mainly clustered into four groups, which was similar as aquaticultural areas classification. Based on the results, present method might be applicable for the quality control of M. veneriformis, or even other marine shellfish aquiculture and their products, and the quality of M. veneriformis might be more related with aquaticultural areas. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. [Application of matrix solid-phase dispersion for the determination of phoxim in crucian carp samples by high performance liquid chromatography].

    PubMed

    Liu, Qian; Liu, Xiaoyu; Qiu, Chaokun; Wang, Xiaobao; Ren, Hongmin

    2009-07-01

    An analytical method was developed for the determination of phoxim residue in the muscle of crucian carp, which involved matrix solid-phase dispersion (MSPD) followed by high performance liquid chromatography (HPLC) with diode array detector. Under optimal conditions, 0.5 g tissue sample was dispersed with 1.5 g Florisil and 0.5 g anhydrous sodium sulphate, transferred to a cartridge. The cartridge was eluted with 25 mL acetone-hexane (40:60, v/v). The phoxim was separated on an ODS column (250 mm x 4.6 mm, 5 microm) with methanol-water (50:50, v/v) as the mobile phase at the flow rate of 0.6 mL/min, then detected by a diode array detector at 270 nm. The injection volume was 20 microL. The linear range of the method was 0.01 - 10 mg/L and the detection limit was 3.3 microg/kg. The average recoveries spiked at the levels of 0.05, 0.1, 1 mg/kg ranged from 88% to 112% with the relative standard deviations (RSDs) of 1.1% -6.3%. The method is quick, simple and can meet the requirement of the analysis of pesticide residues.

  10. Acrylamide in Romanian food using HPLC-UV and a health risk assessment.

    PubMed

    Oroian, Mircea; Amariei, Sonia; Gutt, Gheorghe

    2015-01-01

    The aim of this study was to investigate the level of acrylamide from coffee, potato chips and French fries in Romanian food. According to the European Food Safety Authority, coffee beans, potato chips and French fries have the highest levels of acrylamide. For this survey, 50 samples of coffee beans, 50 samples of potato chips and 25 samples of French fries were purchased from different producers from the Romanian market. Acrylamide levels have been quantified using high-performance liquid chromatography with a diode array detector (HPLC-DAD) method, using water as mobile phase. Health risk assessment was achieved by computing the average daily intake, hazard quotient, cumulative risk, carcinogenic risk and cancer risk. For coffee, potato chips and French fries, acrylamide was not shown to pose a health risk in Romanian food.

  11. Cloud point extraction of Δ9-tetrahydrocannabinol from cannabis resin.

    PubMed

    Ameur, S; Haddou, B; Derriche, Z; Canselier, J P; Gourdon, C

    2013-04-01

    A cloud point extraction coupled with high performance liquid chromatography (HPLC/UV) method was developed for the determination of Δ(9)-tetrahydrocannabinol (THC) in micellar phase. The nonionic surfactant "Dowfax 20B102" was used to extract and pre-concentrate THC from cannabis resin, prior to its determination with a HPLC-UV system (diode array detector) with isocratic elution. The parameters and variables affecting the extraction were investigated. Under optimum conditions (1 wt.% Dowfax 20B102, 1 wt.% Na2SO4, T = 318 K, t = 30 min), this method yielded a quite satisfactory recovery rate (~81 %). The limit of detection was 0.04 μg mL(-1), and the relative standard deviation was less than 2 %. Compared with conventional solid-liquid extraction, this new method avoids the use of volatile organic solvents, therefore is environmentally safer.

  12. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. An on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-total antioxidant capacity detection system applying two antioxidant methods for activity evaluation of the edible flowers from Prunus mume.

    PubMed

    Zhang, Xiaoxia; Lin, Zongtao; Fang, Jinggui; Liu, Meixian; Niu, Yanyan; Chen, Shizhong; Wang, Hong

    2015-10-02

    An on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-total antioxidant capacity detection (HPLC-DAD-ESI-IT-TOF-MS-TACD) system was created for identification and evaluation of antioxidants in Prunus (P.) mume flowers. Applying this system, the HPLC fingerprint, ultraviolet (UV) spectra, mass fragmentations, active profiles against 1,1-diphenylpicryl-2-hydrazyl radical (DPPH•) scavenging activity and ferric reducing antioxidant power (FRAP) of each complex sample were obtained simultaneously after one injection. Synchronous structure identification and activities screening of complex samples were thus accomplished. In this study, 78 compounds were identified from P. mume flowers by their chromatographic behaviors, UV spectra and MS data with the assistance of standard compounds and literature reports. The DPPH and FRAP activity of 24 samples (23 different P. mume varieties and 1 related herbal medicine) were then quantified by their detailed activity profiles from the on-line system, and by the total activity of each sample extract from off-line 96-well plate method. As a result, 21 and 32 compounds in the on-line system showed anti-oxidative effects against DPPH and FRAP, respectively. The established on-line system is efficient, sensitive and reliable to tell the DPPH and FRAP antioxidant activities of individual compound in complex samples, and therefore would be a useful and promising technique for antioxidant screening from different food and medicinal matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Intelligent peak deconvolution through in-depth study of the data matrix from liquid chromatography coupled with a photo-diode array detector applied to pharmaceutical analysis.

    PubMed

    Arase, Shuntaro; Horie, Kanta; Kato, Takashi; Noda, Akira; Mito, Yasuhiro; Takahashi, Masatoshi; Yanagisawa, Toshinobu

    2016-10-21

    Multivariate curve resolution-alternating least squares (MCR-ALS) method was investigated for its potential to accelerate pharmaceutical research and development. The fast and efficient separation of complex mixtures consisting of multiple components, including impurities as well as major drug substances, remains a challenging application for liquid chromatography in the field of pharmaceutical analysis. In this paper we suggest an integrated analysis algorithm functioning on a matrix of data generated from HPLC coupled with photo-diode array detector (HPLC-PDA) and consisting of the mathematical program for the developed multivariate curve resolution method using an expectation maximization (EM) algorithm with a bidirectional exponentially modified Gaussian (BEMG) model function as a constraint for chromatograms and numerous PDA spectra aligned with time axis. The algorithm provided less than ±1.0% error between true and separated peak area values at resolution (R s ) of 0.6 using simulation data for a three-component mixture with an elution order of a/b/c with similarity (a/b)=0.8410, (b/c)=0.9123 and (a/c)=0.9809 of spectra at peak apex. This software concept provides fast and robust separation analysis even when method development efforts fail to achieve complete separation of the target peaks. Additionally, this approach is potentially applicable to peak deconvolution, allowing quantitative analysis of co-eluted compounds having exactly the same molecular weight. This is complementary to the use of LC-MS to perform quantitative analysis on co-eluted compounds using selected ions to differentiate the proportion of response attributable to each compound. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Direct characterization of aqueous extract of Hibiscus sabdariffa using HPLC with diode array detection coupled to ESI and ion trap MS.

    PubMed

    Rodríguez-Medina, Inmaculada C; Beltrán-Debón, Raúl; Molina, Vicente Micol; Alonso-Villaverde, Carlos; Joven, Jorge; Menéndez, Javier A; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2009-10-01

    The phenolic fraction and other polar compounds of the Hibiscus sabdariffa were separated and identified by HPLC with diode array detection coupled to electrospray TOF and IT tandem MS (DAD-HPLC-ESI-TOF-MS and IT-MS). The H. sabdariffa aqueous extract was filtered and directly injected into the LC system. The analysis of the compounds was carried out by RP HPLC coupled to DAD and TOF-MS in order to obtain molecular formula and exact mass. Posterior analyses with IT-MS were performed and the fragmentation pattern and confirmation of the structures were achieved. The H. sabdariffa samples were successfully analyzed in positive and negative ionization modes with two optimized linear gradients. In positive mode, the two most representative anthocyanins and other compounds were identified whereas the phenolic fraction, hydroxycitric acid and its lactone were identified using the negative ionization mode.

  16. Determination of vitamin E and carotenoid pigments by high performance liquid chromatography in shell of Chionoecetes opilio.

    PubMed

    Vilasoa-Martínez, María; Calaza-Ramos, Carina; López-Hernández, Julia; Lage-Yusty, María Asunción; Losada, Perfecto Paseiro; Rodríguez-Bernaldo de Quirós, Ana

    2008-06-09

    This study reports the optimization of a method for the determination of vitamin E and carotenoids in shells of Chionoecetes opilio samples by online HPLC coupled with UV-vis and fluorescence detectors. The carotenoids were determined with diode-array detector (lambda 450 nm) and vitamin E with fluorescence detection (lambda(ex) 288, lambda(em) 331 nm). Two extractions methods were compared, saponification followed by an extraction step and a simple extraction with acetone. The last one was selected because allows to determine all compounds. Linearity, precisions and recoveries achieved for all compounds were satisfactory. Mean concentrations (mg per 100 g dry weight) were; 23.3 for vitamin E, 9.49 for astaxanthin and 0.2 mg for beta-carotene.

  17. Assay of flavonoid aglycones from the species of genus Sideritis (Lamiaceae) from Macedonia with HPLC-UV DAD.

    PubMed

    Janeska, Bisera; Stefova, Marina; Alipieva, Kalina

    2007-09-01

    Flavonoids obtained from Sideritis species (Lamiaceae), S. raeseri and S. scardica, grown in Macedonia were studied. Qualitative and quantitative analyses of the flavonoid aglycones were performed using high-performance liquid chromatography (HPLC) with a UV diode array detector. Extracts were prepared by acid hydrolysis in acetone, re-extraction in ethyl acetate and evaporation to dryness; the residue dissolved in methanol was subjected to HPLC analysis.Isoscutellarein, chryseriol and apigenin were identified in the extracts. Also, a 4'-methyl ether derivative of isoscutellarein was found, together with hypolaetin and its methyl ether derivative, which were identified according to previously isolated glycosides and literature data. Quantitation was performed using calibration with apigenin.According to this screening analysis, the samples of the genus Sideritis from Macedonia are rich in polyhydroxy flavones and analogous with the previously studied Mediterranean Sideritis species from the Ibero-North African and Greek Sideritis species with respect to the presence of 8-OH flavones and their derivatives.

  18. Biogenesis of C-Glycosyl Flavones and Profiling of Flavonoid Glycosides in Lotus (Nelumbo nucifera)

    PubMed Central

    Li, Shan-Shan; Wu, Jie; Chen, Li-Guang; Du, Hui; Xu, Yan-Jun; Wang, Li-Jing; Zhang, Hui-Jin; Zheng, Xu-Chen; Wang, Liang-Sheng

    2014-01-01

    Flavonoids in nine tissues of Nelumbo nucifera Gaertner were identified and quantified by high-performance liquid chromatography with diode array detector (HPLC-DAD) and HPLC-electrospray ionization-mass spectrometry (HPLC-ESI-MSn). Thirty-eight flavonoids were identified; eleven C-glycosides and five O-glycosides were discovered for the first time in N. nucifera. Most importantly, the C-glycosyl apigenin or luteolin detected in lotus plumules proved valuable for deep elucidation of flavonoid composition in lotus tissues and for further utilization as functional tea and medicine materials. Lotus leaves possessed the significantly highest amount of flavonoids (2.06E3±0.08 mg 100 g−1 FW) and separating and purifying the bioactive compound, quercetin 3-O-glucuronide, from leaves showed great potential. In contrast, flavonoids in flower stalks, seed coats and kernels were extremely low. Simultaneously, the optimal picking time was confirmed by comparing the compound contents in five developmental phases. Finally, we proposed the putative flavonoid biosynthesis pathway in N. nucifera. PMID:25279809

  19. Separation and characterization of antioxidants from Spirulina platensis microalga combining pressurized liquid extraction, TLC, and HPLC-DAD.

    PubMed

    Jaime, Laura; Mendiola, José A; Herrero, Miguel; Soler-Rivas, Cristina; Santoyo, Susana; Señorans, F Javier; Cifuentes, Alejandro; Ibáñez, Elena

    2005-11-01

    A new procedure has been developed to separate and characterize antioxidant compounds from Spirulina platensis microalga based on the combination of pressurized liquid extraction (PLE) and different chromatographic procedures, such as TLC, at preparative scale, and HPLC with a diode array detector (DAD). Different solvents were tested for PLE extraction of antioxidants from S. platensis microalga. An optimized PLE process using ethanol (generally recognized as safe, GRAS) as extraction solvent has been obtained that provides natural extracts with high yields and good antioxidant properties. TLC analysis of this ethanolic extract obtained at 115 degrees C for 15 min was carried out and the silica layer was stained with a DPPH (diphenyl-pycril-hydrazyl) radical solution to determine the antioxidant activity of different chromatographic bands. Next, these colored bands were collected for their subsequent analysis by HPLC-DAD, revealing that the compounds with the most important antioxidant activity present in Spirulina extracts were carotenoids, as well as phenolic compounds and degradation products of chlorophylls.

  20. Short range laser obstacle detector. [for surface vehicles using laser diode array

    NASA Technical Reports Server (NTRS)

    Kuriger, W. L. (Inventor)

    1973-01-01

    A short range obstacle detector for surface vehicles is described which utilizes an array of laser diodes. The diodes operate one at a time, with one diode for each adjacent azimuth sector. A vibrating mirror a short distance above the surface provides continuous scanning in elevation for all azimuth sectors. A diode laser is synchronized with the vibrating mirror to enable one diode laser to be fired, by pulses from a clock pulse source, a number of times during each elevation scan cycle. The time for a given pulse of light to be reflected from an obstacle and received is detected as a measure of range to the obstacle.

  1. A novel multi-hyphenated analytical method to simultaneously determine xanthine oxidase inhibitors and superoxide anion scavengers in natural products.

    PubMed

    Qi, Jin; Sun, Li-Qiong; Qian, Steven Y; Yu, Bo-Yang

    2017-09-01

    Natural products, such as rosmarinic acid and apigenin, can act as xanthine oxidase inhibitors (XOIs) as well as superoxide anion scavengers, and have potential for treatment of diseases associated with high uric acid levels and oxidative stress. However, efficient simultaneous screening of these two bioactivities in natural products has been challenging. We have developed a novel method by assembling a multi-hyphenated high performance liquid chromatography (HPLC) system that combines a photo-diode array, chemiluminescence detector and a HPLC system with a variable wavelength detector, to simultaneously detect components that act as both XOIs and superoxide anion scavengers in natural products. Superoxide anion scavenging activity in the analyte was measured by on-line chemiluminescence chromatography based on pyrogallol-luminol oxidation, while xanthine oxidase inhibitory activity was determined by semi-on-line HPLC analysis. After optimizing multiple elements, including chromatographic conditions (e.g., organic solvent concentration and mobile phase pH), concentrations of xanthine/xanthine oxidase and reaction temperature, our validated analytical method was capable of mixed sample analysis. The final results from our method are presented in an easily understood visual format including comprehensive bioactivity data of natural products. Copyright © 2017. Published by Elsevier B.V.

  2. [Determination of canthaxanthin and astaxanthin in egg yolks by reversed phase high performance liquid chromatography with diode array detection].

    PubMed

    He, Kang-Hao; Zou, Xiao-Li; Liu, Xiang; Zeng, Hong-Yan

    2012-01-01

    A method using reversed phase high performance liquid chromatography (RP-HPLC) coupled with diode array detector (DAD) was developed for the simultaneous determination of canthaxanthin and astaxanthin in egg yolks. Samples were extracted with acetonitrile in ultrasonic bath for 20 minutes and then purified by freezing-lipid filtration and solid phase extraction (SPE). After being vaporized to dryness by nitrogen blowing and made up to volume with methanol, the extract solution was chromatographically separated in C18 column with a unitary mobile phase consisting of acetonitrile. The proposed method was validated in terms of linearity, precision, accuracy, and limit of detection (LOD). Regression analysis revealed a good linearity between peak area of each analyte and its concentration (r > or = 0.998). The intra- and inter-day relative standard deviations (RSDs) were less than 3.6% and 5.2%, respectively. LODs of canthaxanthin and astaxanthin were 0.035 and 0.027 microg/mL (S/N = 3). The average recoveries of canthaxanthin and astaxanthin were 91.5% and 88.7%. The proposed method is simple, fast and easy to apply.

  3. Determination and confirmation of isopropyl p-toluenesulfonate in cosmetics by HPLC-diode array detector method and GC-MS.

    PubMed

    Tay, B Y P; Yung, S C; Teoh, T Y

    2016-12-01

    Isopropyl p-toluenesulfonate (IPTS) is a potentially genotoxic by-product formed during the esterification of palm oil-based palmitic and palm kernel oil-based myristic acid with isopropanol to produce isopropyl palmitate or isopropyl myristate. There are no methods described for the analysis of IPTS in cosmetic products. In this work, we have established a simple, precise and accurate method to determine the presence and level of IPTS in various finished cosmetic products which contain palm-based esters in their formulations. An Agilent 1200 series high-performance liquid chromatography (HPLC) unit using a diode-array detector (DAD) has been employed and optimized to detect IPTS in cosmetic products. For the separation, a reverse-phase Hypersil Gold C8 column (5 μm, 4.6 mm i.d. 250 mm) 5 mM tetrabutylammonium phosphate buffer 50 : 50, (v/v) solution in acetonitrile as mobile phase, in isocratic mode and a flow rate of 0.8 mL min -1 were used. A second method using a gas chromatography/mass selective detector GC-MSD was also developed to confirm the IPTS identity in the cosmetic products. Recoveries of IPTS from cosmetic matrices such as a lotion, cleansing milk and a cream ranged from 94.0% to 101.1% with <5% relative standard deviation (%RSD) showing good accuracy and repeatability of the method. The six-point calibration curves (determined over the range 0.5-50 μg mL -1 ) have a correlation coefficient of 0.9999 (based on HPLC peak area) and 0.9998 (based on HPLC peak height). The intra- and interday precisions (measured by the %RSD) of the method were <2% and <5%, respectively, indicating that the developed method is reliable, precise and reproducible. The detection and quantification limit of the method were found to be 0.5 μg mL -1 and 1.6 μg mL -1 , respectively. Analyses of 83 commercial cosmetics showed no presence of IPTS. The validation data indicated that this method was suitable for the quantitative analysis of IPTS in commercial cosmetics. This method is applicable for analyses of trace levels of IPTS in cosmetics and has the advantage of using only simple sample preparation steps. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  4. Screening and identification of radical scavengers from Neo-Taraxacum siphonanthum by online rapid screening method and nuclear magnetic resonance experiments.

    PubMed

    Shi, Shu Yun; Zhang, Yu Ping; Zhou, Hong Hao; Huang, Ke Long; Jiang, Xin Yu

    2010-01-01

    An online rapid screening method, the high-performance liquid chromatography (HPLC)-diode array detector (DAD)-radical scavenging detection (RSD)-electrospray ionization (ESI)-mass spectroscopy (MS)/MS system, was developed for the screening and identification of radical scavengers from Neo-Taraxacum siphonanthum, a new species found in China in 1989. For further characterization, the target compounds were isolated by silica column chromatography, preparative high-performance liquid chromatography (HPLC), HSCCC, and Sephadex LH-20 column chromatography and elucidated on the basis of ultraviolet (UV), ESI-MS/MS, and nuclear magnetic resonance (NMR) spectroscopy, as well as the chemical analysis. Eighteen antioxidative polyphenols (5 caffeic acid derivatives and 13 flavonoid derivatives) were characterized from Neo-T. siphonanthum. The distribution of all compounds was discussed in a chemosystematic context, which suggested that the genera Neo-Taraxacum and Taraxacum might relate chemosystematically.

  5. Extraction, Separation, and Identification of Phenolic Compounds in Virgin Olive Oil by HPLC-DAD and HPLC-MS

    PubMed Central

    Tasioula-Margari, Maria; Tsabolatidou, Eleftheria

    2015-01-01

    The aim of this study was to evaluate the recovery of individual phenolic compounds extracted from virgin olive oil (VOO), from different Greek olive varieties. Sufficient recoveries (90%) of all individual phenolic compounds were obtained using methanol as an extraction solvent, acetonitrile for residue solubilization, and two washing steps with hexane. Moreover, in order to elucidate structural characteristics of phenolic compounds in VOO, high performance liquid chromatography with a diode array detector (HPLC-DAD) at 280 and 340 nm and HPLC coupled to electrospray ionization mass spectrometry (HPLC-ESI-MS) in the negative-ion mode were performed. The most abundant phenolic compounds were oleuropein derivatives with m/z 319 and 377 and ligstroside derivatives with m/z 303, 361. Lignans, such as 1-acetoxypinoresinol and pinoresinol were also present in substantial quantities in the phenolic fraction. However, pinoresinol was co-eluted with dialdehydic form of ligstroside aglycone (DAFLA) and it was not possible to be quantified separately. The phenolic extracts, obtained from different VOO samples, yielded similar HPLC profiles. Differences, however, were observed in the last part of the chromatogram, corresponding to isomers of the aldehydic form of ligstroside aglycone. Oxidized phenolic products, originating from secoiridoids, were also detected. PMID:26783843

  6. Extended short wavelength infrared HgCdTe detectors on silicon substrates

    NASA Astrophysics Data System (ADS)

    Park, J. H.; Hansel, D.; Mukhortova, A.; Chang, Y.; Kodama, R.; Zhao, J.; Velicu, S.; Aqariden, F.

    2016-09-01

    We report high-quality n-type extended short wavelength infrared (eSWIR) HgCdTe (cutoff wavelength 2.59 μm at 77 K) layers grown on three-inch diameter CdTe/Si substrates by molecular beam epitaxy (MBE). This material is used to fabricate test diodes and arrays with a planar device architecture using arsenic implantation to achieve p-type doping. We use different variations of a test structure with a guarded design to compensate for the lateral leakage current of traditional test diodes. These test diodes with guarded arrays characterize the electrical performance of the active 640 × 512 format, 15 μm pitch detector array.

  7. Simultaneous determination of 11 antibiotics and their main metabolites from four different groups by reversed-phase high-performance liquid chromatography-diode array-fluorescence (HPLC-DAD-FLD) in human urine samples.

    PubMed

    Fernandez-Torres, R; Consentino, M Olías; Lopez, M A Bello; Mochon, M Callejon

    2010-05-15

    A new, accurate and sensitive reversed-phase high-performance liquid chromatography (RP-HPLC) as analytical method for the quantitative determination of 11 antibiotics (drugs) and the main metabolites of five of them present in human urine has been worked out, optimized and validated. The analytes belong to four different groups of antibiotics (sulfonamides, tetracyclines, penicillins and anphenicols). The analyzed compounds were sulfadiazine (SDI) and its N(4)-acetylsulfadiazine (NDI) metabolite, sulfamethazine (SMZ) and its N(4)-acetylsulfamethazine (NMZ), sulfamerazine (SMR) and its N(4)-acetylsulfamerazine (NMR), sulfamethoxazole (SMX), trimetroprim (TMP), amoxicillin (AMX) and its main metabolite amoxicilloic acid (AMA), ampicillin (AMP) and its main metabolite ampicilloic acid (APA), chloramphenicol (CLF), thiamphenicol (TIF), oxytetracycline (OXT) and chlortetracycline (CLT). For HPLC analysis, diode array (DAD) and fluorescence (FLD) detectors were used. The separation of the analyzed compounds was conducted by means of a Phenomenex Gemini C(18) (150mm x 4.6mm I.D., particle size 5microm) analytical column with LiChroCART LiChrospher C(18) (4mm x 4mm, particle size 5microm) guard column. Analyzed drugs were determined within 34min using formic acid 0.1% in water and acetonitrile in gradient elution mode as mobile phase. A linear response was observed for all compounds in the range of concentration studied. Two procedures were optimized for sample preparation: a direct treatment with methanol and acetonitrile and a solid phase extraction procedure using Bond Elut Plexa columns. The method was applied to the determination of the analytes in human urine from volunteers under treatment with different pharmaceutical formulations. This method can be successfully applied to routine determination of all these drugs in human urine samples.

  8. Comparison of different extraction procedures for the comprehensive characterization of bioactive phenolic compounds in Rosmarinus officinalis by reversed-phase high-performance liquid chromatography with diode array detection coupled to electrospray time-of-flight mass spectrometry.

    PubMed

    Borrás Linares, I; Arráez-Román, D; Herrero, M; Ibáñez, E; Segura-Carretero, A; Fernández-Gutiérrez, A

    2011-10-21

    In the present work, a comparative study between two environmentally friendly and selective extraction techniques, such as supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) have been carried out focusing in the bioactive phenolic compounds present in Rosmarinus officinalis. For the analysis of the SFE and PLE extracts, a new methodology for qualitative characterization has been developed, based on the use of reversed-phase high-performance liquid chromatography (RP-HPLC), equipped with two different detection systems coupled in series: diode array detector (DAD) and time of flight mass spectrometry (TOF-MS) detector connected via an electrospray ionization interface (ESI). The use of a small particle size C(18) column (1.8 μm) provided a great resolution and made possible the separation of several isomers. Moreover, UV-visible spectrophotometry is a valuable tool for identifying the class of phenolic compounds, whereas MS data enabled to structurally characterize the compounds present in the extracts. The applied methodology was useful for the determination of many well-known phenolic compounds present in R. officinalis, such as carnosol, carnosic acid, rosmadial, rosmanol, genkwanin, homoplantaginin, scutellarein, cirsimaritin and rosmarinic acid, as well as other phenolic compounds present in other species belonging to Lamiaceae family. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. A simple and robust high-performance liquid chromatography coupled to a diode-array detector method for the analysis of genistein in mouse tissues.

    PubMed

    Tamames-Tabar, C; Imbuluzqueta, E; Campanero, M A; Horcajada, P; Blanco-Prieto, M J

    2013-09-15

    A simple liquid-liquid extraction procedure and quantification by high-performance liquid chromatography (HPLC) method coupled to a diode-array detector (DAD) of genistein (GEN) was developed in various mouse biological matrices. 7-ethoxycoumarin was used as internal standard (IS) and peaks were optimally separated using a Kinetex C18 column (2.6μm, 150mm×2.10mm I.D.) at 40°C with an isocratic elution of mobile phase with sodium dihydrogen phosphate 0.01M in water at pH 2.5 and methanol (55:45, v/v), at a flow rate of 0.25mL/min. The injection volume was 10μL. In all cases, the range of GEN recovery was higher than 61%. The low limit of quantification (LLOQ) was 25ng/mL. The linearity of the calibration curves was satisfactory in all cases as shown by correlation coefficients >0.996. The within-day and between-day precisions were <15% and the accuracy ranged in all cases between 90.14% and 106.05%. This method was successfully applied to quantify GEN in liver, spleen, kidney and plasma after intravenous administration of a single dose (30mg/kg) in female BALB/C mice. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Evaluation of Drying Process on the Composition of Black Pepper Ethanolic Extract by High Performance Liquid Chromatography With Diode Array Detector

    PubMed Central

    Namjoyan, Foroogh; Hejazi, Hoda; Ramezani, Zahra

    2012-01-01

    Background Black pepper (Piper nigrum) is one of the well-known spices extensively used worldwide especially in India, and Southeast Asia. The presence of alkaloids in the pepper, namely, piperine and its three stereoisomers, isopiperine, chavicine and isochavicine are well noticed. Objectives The current study evaluated the effect of lyophilization and oven drying on the stability and decomposition of constituents of black pepper ethanolic extract. Materials and Methods In the current study ethanolic extract of black pepper obtained by maceration method was dried using two methods. The effect of freeze and oven drying on the chemical composition of the extract especially piperine and its three isomers were evaluated by HPLC analysis of the ethanolic extract before and after drying processes using diode array detector. The UV Vis spectra of the peaks at piperine retention time before and after each drying methods indicated maximum absorbance at 341.2 nm corresponding to standard piperine. Results The results indicated a decrease in intensity of the chromatogram peaks at approximately all retention times after freeze drying, indicating a few percent loss of piperine and its isomers upon lyophilization. Two impurity peaks were completely removed from the extract. Conclusions In oven dried samples two of the piperine stereoisomers were completely removed from the extract and the intensity of piperine peak was increased. PMID:24624176

  11. Quantification of residual nitrite and nitrate in ham by reverse-phase high performance liquid chromatography/diode array detector.

    PubMed

    Ferreira, I M P L V O; Silva, S

    2008-02-15

    Nitrite and nitrate are used as additives in ham industry to provide colour, taste and protect against clostridia. The classical colorimetric methods widely used to determine nitrite and nitrate are laborious, suffer from matrix interferences and involve the use of toxic cadmium. The use of chromatography is potentially attractive since it is more rapid, sensitive, selective and provides reliable and accurate results. A rapid and cost-effective RP-HPLC method with diode array detector was optimized and validated for quantification of nitrites and nitrates in ham. The chromatographic separation was achieved using a HyPurity C18, 5 microm chromatographic column and gradient elution with 0.01 M n-octylamine and 5mM tetrabutylammonium hydrogenosulphate to pH 6.5. The determinations were performed in the linear range of 0.0125-10.0mg/L for nitrite and 0.0300-12.5 g/L for nitrate. The detection limits were 0.019 and 0.050 mg/kg, respectively. The reliability of the method in terms of precision and accuracy was evaluated. Coefficients of variation lower than 2.89% and 5.47% were obtained for nitrite and nitrate, respectively (n=6). Recoveries of residual nitrite/nitrate ranged between 93.6% and 104.3%. Analysis of cooked and dried ham samples was performed, and the results obtained were in agreement with reference procedures.

  12. SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harpool, K; De La Fuente Herman, T; Ahmad, S

    Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered bymore » an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.« less

  13. Construction of a fast, inexpensive rapid-scanning diode-array detector and spectrometer.

    PubMed

    Carter, T P; Baek, H K; Bonninghausen, L; Morris, R J; van Wart, H E

    1990-10-01

    A 512-element diode-array spectroscopic detection system capable of acquiring multiple spectra at a rate of 5 ms per spectrum with an effective scan rate of 102.9 kHz has been constructed. Spectra with fewer diode elements can also be acquired at scan rates up to 128 kHz. The detector utilizes a Hamamatsu silicon photodiode-array sensor that is interfaced to Hamamatsu driver/amplifier and clock generator boards and a DRA laboratories 12-bit 160-kHz analog-to-digital converter. These are standard, commercially available devices which cost approximately $3500. The system is interfaced to and controlled by an IBM XT microcomputer. Detailed descriptions of the home-built detector housing and control/interface circuitry are presented and its application to the study of the reaction of horseradish peroxidase with hydrogen peroxide is demonstrated.

  14. Identification and quantification of flavonoids and chromes in Baeckea frutescens by using HPLC coupled with diode-array detection and quadruple time-of-flight mass spectrometry.

    PubMed

    Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang

    2015-01-01

    This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.

  15. A linear diode array (JFD-5) for match line in vivo dosimetry in photon and electron beams; evaluation for a chest wall irradiation technique.

    PubMed

    Essers, M; van Battum, L; Heijmen, B J

    2001-11-01

    In vivo dosimetry using thermoluminiscence detectors (TLD) is routinely performed in our institution to determine dose inhomogeneities in the match line region during chest wall irradiation. However, TLDs have some drawbacks: online in vivo dosimetry cannot be performed; generally, doses delivered by the contributing fields are not measured separately; measurement analysis is time consuming. To overcome these problems, the Joined Field Detector (JFD-5), a detector for match line in vivo dosimetry based on diodes, has been developed. This detector and its characteristics are presented. The JFD-5 is a linear array of 5 p-type diodes. The middle three diodes, used to measure the dose in the match line region, are positioned at 5-mm intervals. The outer two diodes, positioned at 3-cm distance from the central diode, are used to measure the dose in the two contributing fields. For three JFD-5 detectors, calibration factors for different energies, and sensitivity correction factors for non-standard field sizes, patient skin temperature, and oblique incidence have been determined. The accuracy of penumbra and match line dose measurements has been determined in phantom studies and in vivo. Calibration factors differ significantly between diodes and between photon and electron beams. However, conversion factors between energies can be applied. The correction factor for temperature is 0.35%/ degrees C, and for oblique incidence 2% at maximum. The penumbra measured with the JFD-5 agrees well with film and linear diode array measurements. JFD-5 in vivo match line dosimetry reproducibility was 2.0% (1 SD) while the agreement with TLD was 0.999+/-0.023 (1 SD). The JFD-5 can be used for accurate, reproducible, and fast on-line match line in vivo dosimetry.

  16. Rapid screening of transferrin-binders in the flowers of Bauhinia blakeana Dunn by on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-transferrin-fluorescence detection system.

    PubMed

    Liu, Meixian; Dong, Jing; Lin, Zongtao; Niu, Yanyan; Zhang, Xiaotian; Jiang, Haixiu; Guo, Ning; Li, Wei; Wang, Hong; Chen, Shizhong

    2016-06-10

    Transferrin (Transferrin, TRF, TF) has drawn increasing attention in cancer therapy due to its potential applications in drug delivery. TF receptor, highly expressed in tumor cells, recognizes and transports Fe(3+)-TF into cells to release iron into cytoplasm. Thus, discovering TF-binding compounds has become an active research area and is of great importance for target therapy. In this study, an on-line analysis method was established for screening TF-binding compounds from the flowers of Bauhinia blakeana Dunn using a high-performance liquid chromatography-diode-array detector-multi-stage mass spectrometry-transferrin-fluorescence detector (HPLC-DAD-MS(n)-TF-FLD) method. As a result, 33 of 80 identified or tentatively characterized compounds in the sample were TF-binding active. Twenty-five flavonol glycosides and eight phenolic acids were identified as TF-binders. Twelve of these active compounds together with six standard compounds were used to study the dose-response effects and structure-activity relationships of flavonoids and phenolic acids. The method was validated by vitexin with a good linearity in the range of concentrations used in the study. The limit of detection for vitexin was 0.1596 nmol. Our study indicated that the established method is simple, rapid and sensitive for screening TF-binding active compounds in the extract of Bauhinia blakeana Dunn, and therefore is important for discovering potential anti-cancer ingredients from complex samples for TF related drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Integrating IR detector imaging systems

    NASA Technical Reports Server (NTRS)

    Bailey, G. C. (Inventor)

    1984-01-01

    An integrating IR detector array for imaging is provided in a hybrid circuit with InSb mesa diodes in a linear array, a single J-FET preamplifier for readout, and a silicon integrated circuit multiplexer. Thin film conductors in a fan out pattern deposited on an Al2O3 substrate connect the diodes to the multiplexer, and thick film conductors also connect the reset switch and preamplifier to the multiplexer. Two phase clock pulses are applied with a logic return signal to the multiplexer through triax comprised of three thin film conductors deposited between layers. A lens focuses a scanned image onto the diode array for horizontal read out while a scanning mirror provides vertical scan.

  18. High-performance liquid chromatography study of the enantiomer separation of chrysanthemic acid and its analogous compounds on a terguride-based stationary phase.

    PubMed

    Dondi, M; Flieger, M; Olsovska, J; Polcaro, C M; Sinibaldi, M

    1999-10-29

    The direct enantioseparation of chrysanthemic acid [2,2-dimethyl-3-(2-methylpropenyl)-cyclopropanecarboxylic acid] and its halogen-substituted analogues was systematically studied by HPLC using a terguride-based chiral stationary phase in combination with a UV diode array and chiroptical detectors. Isomers with (1R) configuration always eluted before those with (IS) configuration. The elution sequence of cis- and trans-isomers was strongly affected by mobile phase pH, whereas the enantioselectivity remained the same. Conditions for the separation of all the enantiomers were also examined. This method was used for monitor the hydrolytic degradation products of Cyfluthrin (Baythroid) in soil under laboratory conditions.

  19. Determination of Trace Level Triclosan in Water by Online Preconcentration and HPLC-UV Diode Array

    EPA Science Inventory

    An online high performance liquid chromatography (HPLC) method for the detection and quantification of trace levels of triclosan in water is discussed. Triclosan, an anti-bacterial agent, and related compounds have been shown to reach municipal waste waters through the disposal ...

  20. Identification and determination of flavonoids, carotenoids and chlorophyll concentration in Cynodon dactylon (L.) by HPLC analysis.

    PubMed

    Muthukrishnan, Saradha Devi; Kaliyaperumal, Ashokkumar; Subramaniyan, Annapoorani

    2015-01-01

    Cynodon dactylon (L.) is a potent medicinal plant in the traditional and current Indian medicinal systems. The objective of this research was to find out the levels of flavonoids, carotenoids and chlorophyll b in C. dactylon leaves by high-performance liquid chromatography (HPLC) equipped with a diode array detector. HPLC analysis revealed that total carotenoid and total flavonoid concentration were 62 mg/100 g and 249.1 μg/g, respectively. The mean chlorophyll b was 85.1 mg/100 g in C. dactylon. Among the flavonoids, quercetin (164.7 μg/g) was the major flavonoid followed by kaempferol (48.2 μg/g), rutin (18.4 μg/g), catechin (12.1 μg/g) and myricetin (5.7 μg/g). Of the carotenoids, β-carotene (35.2 mg/100 g) was predominant followed by lutein (17.0 mg/100 g), violaxanthin (5.8 mg/100 g) and zeaxanthin (4.2 mg/100 g). Chlorophyll b concentration was 85.1 mg/100 g in C. dactylon. The results of this investigation should be useful information for further pharmacological studies.

  1. Two-dimensional fingerprinting approach for comparison of complex substances analysed by HPLC-UV and fluorescence detection.

    PubMed

    Ni, Yongnian; Liu, Ying; Kokot, Serge

    2011-02-07

    This work is concerned with the research and development of methodology for analysis of complex mixtures such as pharmaceutical or food samples, which contain many analytes. Variously treated samples (swill washed, fried and scorched) of the Rhizoma atractylodis macrocephalae (RAM) traditional Chinese medicine (TCM) as well as the common substitute, Rhizoma atractylodis (RA) TCM were chosen as examples for analysis. A combined data matrix of chromatographic 2-D HPLC-DAD-FLD (two-dimensional high performance liquid chromatography with diode array and fluorescence detectors) fingerprint profiles was constructed with the use of the HPLC-DAD and HPLC-FLD individual data matrices; the purpose was to collect maximum information and to interpret this complex data with the use of various chemometrics methods e.g. the rank-ordering multi-criteria decision making (MCDM) PROMETHEE and GAIA, K-nearest neighbours (KNN), partial least squares (PLS), back propagation-artificial neural networks (BP-ANN) methods. The chemometrics analysis demonstrated that the combined 2-D HPLC-DAD-FLD data matrix does indeed provide more information and facilitates better performing classification/prediction models for the analysis of such complex samples as the RAM and RA ones noted above. It is suggested that this fingerprint approach is suitable for analysis of other complex, multi-analyte substances.

  2. Performance measurements of hybrid PIN diode arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jernigan, J.G.; Arens, J.F.; Kramer, G.

    We report on the successful effort to develop hybrid PIN diode arrays and to demonstrate their potential as components of vertex detectors. Hybrid pixel arrays have been fabricated by the Hughes Aircraft Co. by bump bonding readout chips developed by Hughes to an array of PIN diodes manufactured by Micron Semiconductor Inc. These hybrid pixel arrays were constructed in two configurations. One array format having 10 {times} 64 pixels, each 120 {mu}m square, and the other format having 256 {times} 256 pixels, each 30 {mu}m square. In both cases, the thickness of the PIN diode layer is 300 {mu}m. Measurementsmore » of detector performance show that excellent position resolution can be achieved by interpolation. By determining the centroid of the charge cloud which spreads charge into a number of neighboring pixels, a spatial resolution of a few microns has been attained. The noise has been measured to be about 300 electrons (rms) at room temperature, as expected from KTC and dark current considerations, yielding a signal-to-noise ratio of about 100 for minimum ionizing particles. 4 refs., 13 figs.« less

  3. Flexible amorphous silicon PIN diode x-ray detectors

    NASA Astrophysics Data System (ADS)

    Marrs, Michael; Bawolek, Edward; Smith, Joseph T.; Raupp, Gregory B.; Morton, David

    2013-05-01

    A low temperature amorphous silicon (a-Si) thin film transistor (TFT) and amorphous silicon PIN photodiode technology for flexible passive pixel detector arrays has been developed using active matrix display technology. The flexible detector arrays can be conformed to non-planar surfaces with the potential to detect x-rays or other radiation with an appropriate conversion layer. The thin, lightweight, and robust backplanes may enable the use of highly portable x-ray detectors for use in the battlefield or in remote locations. We have fabricated detector arrays up to 200 millimeters along the diagonal on a Gen II (370 mm x 470 mm rectangular substrate) using plasma enhanced chemical vapor deposition (PECVD) a-Si as the active layer and PECVD silicon nitride (SiN) as the gate dielectric and passivation. The a-Si based TFTs exhibited an effective saturation mobility of 0.7 cm2/V-s, which is adequate for most sensing applications. The PIN diode material was fabricated using a low stress amorphous silicon (a-Si) PECVD process. The PIN diode dark current was 1.7 pA/mm2, the diode ideality factor was 1.36, and the diode fill factor was 0.73. We report on the critical steps in the evolution of the backplane process from qualification of the low temperature (180°C) TFT and PIN diode process on the 150 mm pilot line, the transfer of the process to flexible plastic substrates, and finally a discussion and demonstration of the scale-up to the Gen II (370 x 470 mm) panel scale pilot line.

  4. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  5. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  6. Real-time continuous-wave terahertz line scanner based on a compact 1 × 240 InGaAs Schottky barrier diode array detector.

    PubMed

    Han, Sang-Pil; Ko, Hyunsung; Kim, Namje; Lee, Won-Hui; Moon, Kiwon; Lee, Il-Min; Lee, Eui Su; Lee, Dong Hun; Lee, Wangjoo; Han, Seong-Tae; Choi, Sung-Wook; Park, Kyung Hyun

    2014-11-17

    We demonstrate real-time continuous-wave terahertz (THz) line-scanned imaging based on a 1 × 240 InGaAs Schottky barrier diode (SBD) array detector with a scan velocity of 25 cm/s, a scan line length of 12 cm, and a pixel size of 0.5 × 0.5 mm². Foreign substances, such as a paper clip with a spatial resolution of approximately 1 mm that is hidden under a cracker, are clearly detected by this THz line-scanning system. The system consists of the SBD array detector, a 200-GHz gyrotron source, a conveyor system, and several optical components such as a high-density polyethylene cylindrical lens, metal cylindrical mirror, and THz wire-grid polarizer. Using the THz polarizer, the signal-to-noise ratio of the SBD array detector improves because the quality of the source beam is enhanced.

  7. Fill-factor improvement of Si CMOS single-photon avalanche diode detector arrays by integration of diffractive microlens arrays.

    PubMed

    Intermite, Giuseppe; McCarthy, Aongus; Warburton, Ryan E; Ren, Ximing; Villa, Federica; Lussana, Rudi; Waddie, Andrew J; Taghizadeh, Mohammad R; Tosi, Alberto; Zappa, Franco; Buller, Gerald S

    2015-12-28

    Single-photon avalanche diode (SPAD) detector arrays generally suffer from having a low fill-factor, in which the photo-sensitive area of each pixel is small compared to the overall area of the pixel. This paper describes the integration of different configurations of high efficiency diffractive optical microlens arrays onto a 32 × 32 SPAD array, fabricated using a 0.35 µm CMOS technology process. The characterization of SPAD arrays with integrated microlens arrays is reported over the spectral range of 500-900 nm, and a range of f-numbers from f/2 to f/22. We report an average concentration factor of 15 measured for the entire SPAD array with integrated microlens array. The integrated SPAD and microlens array demonstrated a very high uniformity in overall efficiency.

  8. Simultaneous quantitative determination of six active components in traditional Chinese medicinal preparation Cerebralcare Granule® by RP-HPLC coupled with diode array detection for quality control.

    PubMed

    Wang, Xiang-yang; Ma, Xiao-hui; Li, Wei; Chu, Yang; Guo, Jia-hua; Zhou, Shui-ping; Zhu, Yong-hong

    2014-09-01

    A simple, accurate and reliable method for the simultaneous separation and determination of six active components (protocatechuic acid, chlorogenic acid, caffeic acid, paeoniflorin, ferulic acid and rosmarinic acid) in traditional Chinese medicinal preparation Cerebralcare Granule(®) (CG) was developed using reverse-phase high-performance liquid chromatography coupled with diode array detector detection. The chromatographic separation was performed on a Hypersil GOLD C18 column with aqueous formic acid (0.1%, v/v) and acetonitrile as mobile phase at a flow rate of 0.2 ml/min at 30 °C. Because of the different UV characteristics of these components, change detection wavelength method was used for quantitative analysis. All of the analytes showed good linearity (r > 0.9992). The established method showed good precision and relative standard deviations (%) for intra-day and inter-day variations of 0.15-1.81 and 0.11-1.98%, respectively. The validated method was successfully applied to the simultaneously determination of six active components in CG from different batches. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Quantification of lycopene in the processed tomato-based products by means of the light-emitting diode (LED) and compact photoacoustic (PA) detector

    NASA Astrophysics Data System (ADS)

    Bicanic, D.; Skenderović, H.; Marković, K.; Dóka, O.; Pichler, L.; Pichler, G.; Luterotti, S.

    2010-03-01

    The combined use of a high power light emitting diode (LED) and the compact photoacoustic (PA) detector offers the possibility for a rapid (no extraction needed), accurate (precision 1.5%) and inexpensive quantification of lycopene in different products derived from the thermally processed tomatoes. The concentration of lycopene in selected products ranges from a few mg to several tens mg per 100 g fresh weight. The HPLC was used as the well established reference method.

  10. HPLC-DAD-MS identification of bioactive secondary metabolites from Ferula communis roots.

    PubMed

    Arnoldi, Lolita; Ballero, Mauro; Fuzzati, Nicola; Maxia, Andrea; Mercalli, Enrico; Pagni, Luca

    2004-06-01

    A simple HPLC method was developed to distinguish between 'poisonous' and 'non-poisonous' chemotypes of Ferula communis. The method was performed on a C8 reverse phase analytical column using a binary eluent (aqueous TFA 0.01%-TFA 0.01% in acetonitrile) under gradient condition. The two chemotypes showed different fingerprints. The identification of five coumarins and eleven daucane derivatives by HPLC-diode array detection (HPLC-DAD) and HPLC-MS is described. A coumarin, not yet described, was detected. Copyright 2004 Elsevier B.V.

  11. Simultaneous determination of four neuroprotective compounds of Tilia amurensis by high performance liquid chromatography coupled with diode array detector

    PubMed Central

    Lee, Bohyung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Background: Tilia amurensis consists of various compounds, such as flavonoids and terpenoids. Objective: A simple and reliable high performance liquid chromatography (HPLC) coupled with the diode array detector (DAD) method has been established for simultaneous determination of epicatechin, nudiposide, lyoniside, and scopoletin isolated from Tilia amurensis. Materials and Methods: Optimum separations were obtained with a SHISEIDO C18 column by gradient eluton, with 0.1% Trifluoroacetic acid (TFA) water-methanol as the mobile phase. The gradient elution system was completed within 40 minutes. The flow rate and detection wavelength were 1 mL/minute, 205 nm, 250 nm, and 280 nm, respectively. Results: Validation of the analytical method was evaluated by linearity, precision, and the accuracy test. The calibration curve was linear over the established range with R2 > 0.997. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01-15.20 μg/mL and 0.03-46.06 μg/mL. The method exhibited an intraday and interday precision range of 96.25-105.66% and 93.52-109.92%, respectively (RSD <2.80%). The recoveries and relative standard deviation (RSD) of the four compounds in Tilia amurensis were in the range of 90.42-104.84% and 0.2-2.58%. Conclusion: This developed method was accurate and reliable for the quality evaluation of the four compounds isolated from Tilia amurensis. PMID:25210303

  12. Simultaneous Extraction Optimization and Analysis of Flavonoids from the Flowers of Tabernaemontana heyneana by High Performance Liquid Chromatography Coupled to Diode Array Detector and Electron Spray Ionization/Mass Spectrometry

    PubMed Central

    Sathishkumar, Thiyagarajan; Baskar, Ramakrishnan; Aravind, Mohan; Tilak, Suryanarayanan; Deepthi, Sri; Bharathikumar, Vellalore Maruthachalam

    2013-01-01

    Flavonoids are exploited as antioxidants, antimicrobial, antithrombogenic, antiviral, and antihypercholesterolemic agents. Normally, conventional extraction techniques like soxhlet or shake flask methods provide low yield of flavonoids with structural loss, and thereby, these techniques may be considered as inefficient. In this regard, an attempt was made to optimize the flavonoid extraction using orthogonal design of experiment and subsequent structural elucidation by high-performance liquid chromatography-diode array detector-electron spray ionization/mass spectrometry (HPLC-DAD-ESI/MS) techniques. The shake flask method of flavonoid extraction was observed to provide a yield of 1.2 ± 0.13 (mg/g tissue). With the two different solvents, namely, ethanol and ethyl acetate, tried for the extraction optimization of flavonoid, ethanol (80.1 mg/g tissue) has been proved better than ethyl acetate (20.5 mg/g tissue). The optimal conditions of the extraction of flavonoid were found to be 85°C, 3 hours with a material ratio of 1 : 20, 75% ethanol, and 1 cycle of extraction. About seven different phenolics like robinin, quercetin, rutin, sinapoyl-hexoside, dicaffeic acid, and two unknown compounds were identified for the first time in the flowers of T. heyneana. The study has also concluded that L16 orthogonal design of experiment is an effective method for the extraction of flavonoid than the shake flask method. PMID:25969771

  13. Separation and quantitation of colour pigments of chili powder (Capsicum frutescens) by high-performance liquid chromatography-diode array detection.

    PubMed

    Cserháti, T; Forgács, E; Morais, M H; Mota, T; Ramos, A

    2000-10-27

    The performance of reversed-phase thin-layer (RP-TLC) and reversed-phase high-performance liquid chromatography (RP-HPLC) was compared for the separation and determination of the colour pigments of chili (Capsicum frutescens) powder using a wide variety of eluent systems. No separation of pigments was achieved in RP-TLC, however, it was established that tetrahydrofuran shows an unusually high solvent strength. RP-HPLC using water-methanol-acetonitrile gradient elution separated the chili pigments in many fractions. Diode array detection (DAD) indicated that yellow pigments are eluted earlier than the red ones and chili powder contains more yellow pigments than common paprika powders. It was established that the very different absorption spectra of pigments make the use of DAD necessary.

  14. Contribution of flavonoids to the overall radical scavenging activity of olive (Olea europaea L.) leaf polar extracts.

    PubMed

    Goulas, Vlassios; Papoti, Vassiliki T; Exarchou, Vassiliki; Tsimidou, Maria Z; Gerothanassis, Ioannis P

    2010-03-24

    The contribution of flavonoids to the overall radical scavenging activity of olive leaf polar extracts, known to be good sources of oleuropein related compounds, was examined. Off line and on line HPLC-DPPH(*) assays were employed, whereas flavonoid content was estimated colorimetrically. Individual flavonoid composition was first assessed by RP-HPLC coupled with diode array and fluorescence detectors and verified by LC-MS detection system. Olive leaf was found a robust source of flavonoids regardless sampling parameters (olive cultivar, leaf age or sampling date). Total flavonoids accounted for the 13-27% of the total radical scavenging activity assessed using the on line protocol. Luteolin 7-O-glucoside was one of the dominant scavengers (8-25%). Taking into consideration frequency of appearance the contribution of luteolin (3-13%) was considered important, too. Our findings support that olive leaf, except for oleuropein and related compounds, is also a stable source of bioactive flavonoids.

  15. Development and validation of a high performance liquid chromatographic method for simultaneous determination of vitamins A and D3 in fluid milk products.

    PubMed

    Chen, Yang; Reddy, Ravinder M; Li, Wenjing; Yettlla, Ramesh R; Lopez, Salvador; Woodman, Michael

    2015-01-01

    An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milk samples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade "A" fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL, respectively. Average recoveries between 94 and 110% and SD values ranging from 2.7 to 6.9% were obtained for both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.

  16. OPTIMIZATION AND VALIDATION OF HPLC METHOD FOR TETRAMETHRIN DETERMINATION IN HUMAN SHAMPOO FORMULATION.

    PubMed

    Zeric Stosic, Marina Z; Jaksic, Sandra M; Stojanov, Igor M; Apic, Jelena B; Ratajac, Radomir D

    2016-11-01

    High-performance liquid chromatography (HPLC) method with diode array detection (DAD) were optimized and validated for separation and determination of tetramethrin in an antiparasitic human shampoo. In order to optimize separation conditions, two different columns, different column oven temperatures, as well as mobile phase composition and ratio, were tested. Best separation was achieved on the Supelcosil TM LC-18- DB column (4.6 x 250 mm), particle size 5 jim, with mobile phase methanol : water (78 : 22, v/v) at a flow rate of 0.8 mL/min and at temperature of 30⁰C. The detection wavelength of the detector was set at 220 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity [r2 = 0.9997]. Accuracy of the method defined as a mean recovery of tetramethrin from shampoo matrix was 100.09%. The advantages of this method are that it can easily be used for the routine analysis of drug tetramethrin in pharmaceutical formulas and in all pharmaceutical researches involving tetramethrin.

  17. Simultaneous determination of citrus limonoid aglycones and glucosides by high performance liquid chromatography.

    PubMed

    Vikram, Amit; Jayaprakasha, G K; Patil, Bhimanagouda S

    2007-05-08

    High performance liquid chromatography (HPLC) method has been developed for simultaneous quantification of limonoid aglycones and glucosides on a reversed phase C18 column using a binary solvent system, coupled with diode array detector. Seven limonoids such as limonin, nomilin, isolimonic acid, ichangin, isoobacunoic acid, limonin 17-beta-D glucopyranoside and deacetyl nomilinic acid 17-beta-D glucopyranoside were separated and detected at 210 nm. Furthermore, limonoids were separated, identified and quantified in four varieties of citrus fruits and seeds using developed method. Limonin and limonin glucoside were found to be the predominant limonoid aglycone and glucoside, respectively, in all tested samples. The sensitivity of the method was found to be 0.25-0.50 microg for tested limonoids.

  18. Characterization of a novel two dimensional diode array the "magic plate" as a radiation detector for radiation therapy treatment.

    PubMed

    Wong, J H D; Fuduli, I; Carolan, M; Petasecca, M; Lerch, M L F; Perevertaylo, V L; Metcalfe, P; Rosenfeld, A B

    2012-05-01

    Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the "magic plate" (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. The prototype MP is an 11 × 11 detector array based on thin (50 μm) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary "drop-in" technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180°. Angular dependence was within 3.5% for the gantry angles ± 75°. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 × 30 cm(2) field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with "drop-in" packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

  19. Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235nm.

    PubMed

    da Silveira Petruci, João Flavio; Liebetanz, Michael G; Cardoso, Arnaldo Alves; Hauser, Peter C

    2017-08-25

    In this communication, we describe a flow-through optical absorption detector for HPLC using for the first time a deep-UV light-emitting diode with an emission band at 235nm as light source. The detector is also comprised of a UV-sensitive photodiode positioned to enable measurement of radiation through a flow-through cuvette with round aperture of 1mm diameter and optical path length of 10mm, and a second one positioned as reference photodiode; a beam splitter and a power supply. The absorbance was measured and related to the analyte concentration by emulating the Lambert-Beer law with a log-ratio amplifier circuitry. This detector showed noise levels of 0.30mAU, which is comparable with our previous LED-based detectors employing LEDs at 280 and 255nm. The detector was coupled to a HPLC system and successfully evaluated for the determination of the anti-diabetic drugs pioglitazone and glimepiride in an isocratic separation and the benzodiazepines flurazepam, oxazepam and clobazam in a gradient elution. Good linearities (r>0.99), a precision better than 0.85% and limits of detection at sub-ppm levels were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Identification of geometrical isomers and comparison of different isomeric samples of astaxanthin.

    PubMed

    Qiu, Dan; Wu, Yue-Chan; Zhu, Wen-Li; Yin, Hong; Yi, Long-Tao

    2012-09-01

    A high-performance liquid chromatographic (HPLC) analysis system for isomeric astaxanthin was developed. The separation system consisted of a C(30) column and an elution system of methanol/MTBE/water/dichloromethane (77:13:8:2, v/v/v/v). Using the combination of HPLC diode array detector and HPLC atmospheric pressure chemical ionization mass spectrometry, 11 geometrical isomers and 4 epoxides of astaxanthin were successfully identified. Referred to crystal, only isomerization with different degrees was found for solvent dissolving and iodine catalysis, while melting of astaxanthin caused isomerization, slight oxidation, and more noticeable polymerization confirmed by gel permeation chromatography. Chemical changes in isomeric samples all caused a decrease in UV content. The vibrational spectra (infrared and Raman) showed that epoxide was the only new functional group generated for melting. Changes of several key bands and formations of new bands were found in iodine catalysis and melting samples because of isomerization. Practical Application:  Eleven geometrical isomers and 4 epoxides, which were normally generated for solvent dissolving, iodine catalysis, and melting of astaxanthin, have been identified by C(30) -HPLC-MS technology. Furthermore, different samples were measured by gel permeation chromatography, UV, infrared, and Raman, based on the analysis of messages, the effect of each processing was well understood. © 2012 Institute of Food Technologists®

  1. Performance Improvement of Long-Wave Infrared InAs/GaSb Strained-Layer Superlattice Detectors Through Sulfur-Based Passivation

    DTIC Science & Technology

    2012-01-01

    14]. The detector material was processed into a variable area diode array (VADA) of square and circular mesa diodes with the size of diode mesa sides...processed as single element detectors with 410 lm 410 lm square mesas having circular apertures ranging in diameter from 25 to 300 lm. The processing was...passivations schemes with perimeter-to-area ratio (P/A) of 1600 cm1 ( mesa side size is 25 lm). Fig. 3. Inverse of the dynamic resistance area product (RdA

  2. Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples.

    PubMed

    Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J

    2006-09-01

    A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-mum polydimethylsiloxane-divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-mum PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.

  3. Isolation and structural characterization of a novel sibutramine analogue, chlorosipentramine, in a slimming dietary supplement, by using HPLC-PDA, LC-Q-TOF/MS, FT-IR, and NMR.

    PubMed

    Yun, Jisuk; Shin, Kye Jung; Choi, Jangduck; Jo, Cheon-Ho

    2018-05-01

    A novel sibutramine analogue was detected in a slimming formula by high performance liquid chromatography with a photo diode detector array (HPLC-PDA). The unknown compound exhibited an ultraviolet (UV) spectrum that was similar to that of chlorosibutramine, despite having a different HPLC retention time. Further analysis of the slimming formula by LC-quadrupole time-of-flight mass spectrometry (LC-Q-TOF/MS) showed that the unknown compound had the formula C 18 H 27 Cl 2 N. To elucidate the structure of this new sibutramine analogue, the target compound in the slimming formula was isolated on a preparative-LC system equipped with a PDA. After analysis by fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectroscopy, the unknown compound was identified as a sibutramine analogue in which the iso-butyl group on the side chain is replaced with an iso-pentyl group. This new sibutramine analogue was identified to be 1-(1-(3,4-dichlorophenyl)cyclobutyl)-N,N,4-trimethylpentan-1-amine and has been named as chlorosipentramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. First report in a river in France of the benthic cyanobacterium Phormidium favosum producing anatoxin-a associated with dog neurotoxicosis.

    PubMed

    Gugger, Muriel; Lenoir, Séverine; Berger, Céline; Ledreux, Aurélie; Druart, Jean-Claude; Humbert, Jean-François; Guette, Catherine; Bernard, Cécile

    2005-06-01

    The first identification of anatoxin-a in a French lotic system is reported. Rapid deaths of dogs occurred in 2003 after the animals drank water from the shoreline of the La Loue River in eastern France. Sediments, stones and macrophytes surfaces at the margin of the river were covered by a thick biofilm containing large quantities of several benthic species of filamentous, non-heterocystous cyanobacteria. Known cyanotoxins, such as microcystins, saxitoxins and anatoxins were screened from biofilm samples by biochemical and analytical assays. A compound with similar UV spectra to the anatoxin-a standard was detected by high-performance liquid chromatography (HPLC) coupled with photo-diode array detector. This toxin was further identified by HPLC coupled with a UV detector and by electrospray ionisation-Quadrupole-Time-Of-Flight mass spectrometer, and confirmed by tandem mass spectrometry. These two techniques were necessary to discriminate anatoxin-a in phenylalanine-containing matrices such as liver samples of poisoned dogs. The toxin and the aromatic amino acid, phenylalanine, present the same pseudomolecular ion at m/z 166, but have differing fragmentation patterns, retention times and UV spectra. Finally, several cyanobacterial strains were isolated from the green biofilm and tested for anatoxin-a production. Phormidium favosum was identified as a new anatoxin-a producing species.

  5. The "collimator monitoring fill factor" of a two-dimensional detector array, a measure of its ability to detect collimation errors.

    PubMed

    Stelljes, Tenzin Sonam; Looe, Hui Khee; Harder, Dietrich; Poppe, Björn

    2017-03-01

    Two-dimensional detector arrays are routinely used for constancy checks and treatment plan verification in photon-beam radiotherapy. In addition to the spatial resolution of the dose profiles, the "coverage" of the radiation field with respect to the detection of any beam collimation deficiency appears as the second characteristic feature of a detector array. The here proposed "collimator monitoring fill factor" (CM fill factor) has been conceived to serve as a quantitative characteristic of this "coverage". The CM fill factor is defined as the probability of a 2D array to detect any collimator position error. Therefore, it is represented by the ratio of the "sensitive area" of a single detector, in which collimator position errors are detectable, and the geometrical "cell area" associated with this detector within the array. Numerical values of the CM fill factor have been Monte Carlo simulated for 2D detector arrays equipped with air-vented ionization chambers, liquid-filled ionization chambers and diode detectors and were compared with the "FWHM fill factor" defined by Gago-Arias et al. (2012). For arrays with vented ionization chambers, the differences between the CM fill factor and the FWHM fill factor are moderate, but occasionally the latter exceeds unity. For narrower detectors such as liquid-filled ionization chambers and Si diodes and for small sampling distances, large differences between the FWHM fill factor and the CM fill factor have been observed. These differences can be explained by the shapes of the fluence response functions of these narrow detectors. A new parameter "collimator monitoring fill factor" (CM fill factor), applicable to quantitate the collimator position error detection probability of a 2D detector array, has been proposed. It is designed as a help in classifying the clinical performance of two-dimensional detector arrays in photon-beam radiotherapy. © 2017 American Association of Physicists in Medicine.

  6. Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R.; Pain, Bedabrata

    1997-01-01

    A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

  7. Determination of fucoxanthin isomers in microalgae (Isochrysis sp.) by high-performance liquid chromatography coupled with diode-array detector multistage mass spectrometry coupled with positive electrospray ionization.

    PubMed

    Crupi, Pasquale; Toci, Aline Theodore; Mangini, Silvio; Wrubl, Federico; Rodolfi, Liliana; Tredici, Mario R; Coletta, Antonio; Antonacci, Donato

    2013-05-15

    Due to their health benefits, there is growing interest in the production and use of carotenoids from natural sources, e.g. microalgae. To date, only Haematococcus pluvialis and Dunaliella, that accumulate, respectively, astaxanthin and β-carotene in large quantities, are grown commercially. However, interest is also being focused on other xanthophylls, such as (all-E)-fucoxanthin characterized by anti-obesity and anti-carcinogenic effects. In this regard, rigorous chemical and analytical techniques following preparative isolation of components are needed to unequivocally identify individual carotenoids in microalgae. The carotenoid profile of Isochrysis sp. biomass, produced in closed photobioreactors, was determined by reversed-phase C30 (RP-30) high-performance liquid chromatography coupled with diode-array detector mass spectrometry using positive electrospray ionization (HPLC/DAD-MS/ESI(+) ) analysis. Additionally, multistage mass spectrometry (MS(n) ) analyses, together with fine structures of the UV-vis spectra, were used to differentiate structural and geometrical isomers. This technique allowed the simultaneous determination of geometrical, isomers of fucoxanthin (all-E-fucoxanthin, 13Z-, 13'Z- and 9'Z-fucoxanthin), diatoxanthin and 5,8-epoxydiadinoxanthin diasteroisomers (R/S). The analyzed extracts contained fucoxanthin isomers as the major carotenoids and, in particular, (all-E)-fucoxanthin was the main geometrical isomer (~85%) found at a concentration of 17 mg/g of the lyophilized biomass. Considering the high content of fucoxanthin in Isochrysis sp. biomass, the microalga could be proposed as a source of this compound for nutraceutical and pharmaceutical applications. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Quality assessment of crude and processed Arecae semen based on colorimeter and HPLC combined with chemometrics methods.

    PubMed

    Sun, Meng; Yan, Donghui; Yang, Xiaolu; Xue, Xingyang; Zhou, Sujuan; Liang, Shengwang; Wang, Shumei; Meng, Jiang

    2017-05-01

    Raw Arecae Semen, the seed of Areca catechu L., as well as Arecae Semen Tostum and Arecae semen carbonisata are traditionally processed by stir-baking for subsequent use in a variety of clinical applications. These three Arecae semen types, important Chinese herbal drugs, have been used in China and other Asian countries for thousands of years. In this study, the sensory technologies of a colorimeter and sensitive validated high-performance liquid chromatography with diode array detection were employed to discriminate raw Arecae semen and its processed drugs. The color parameters of the samples were determined by a colorimeter instrument CR-410. Moreover, the fingerprints of the four alkaloids of arecaidine, guvacine, arecoline and guvacoline were surveyed by high-performance liquid chromatography. Subsequently, Student's t test, the analysis of variance, fingerprint similarity analysis, hierarchical cluster analysis, principal component analysis, factor analysis and Pearson's correlation test were performed for final data analysis. The results obtained demonstrated a significant color change characteristic for components in raw Arecae semen and its processed drugs. Crude and processed Arecae semen could be determined based on colorimetry and high-performance liquid chromatography with a diode array detector coupled with chemometrics methods for a comprehensive quality evaluation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Identification of phenanthrene derivatives in Aerides rosea (Orchidaceae) using the combined systems HPLC-ESI-HRMS/MS and HPLC-DAD-MS-SPE-UV-NMR.

    PubMed

    Cakova, Veronika; Urbain, Aurélie; Antheaume, Cyril; Rimlinger, Nicole; Wehrung, Patrick; Bonté, Frédéric; Lobstein, Annelise

    2015-01-01

    In our continued efforts to contribute to the general knowledge on the chemical diversity of orchids, we have decided to focus our investigations on the Aeridinae subtribe. Following our previous phytochemical study of Vanda coerulea, which has led to the identification of phenanthrene derivatives, a closely related species, Aerides rosea Lodd. ex Lindl. & Paxton, was chosen for investigation. To identify new secondary metabolites, and to avoid isolation of those already known, by means of the combined systems HPLC-DAD(diode-array detector) with high-resolution tandem mass spectrometry (HRMS/MS) and HPLC-DAD-MS-SPE(solid-phase extraction)-UV-NMR. A dereplication strategy was developed using a HPLC-DAD-HRMS/MS targeted method and applied to fractions from A. rosea stem extract. Characterisation of unknown minor compounds was then performed using the combined HPLC-DAD-MS-SPE-UV-NMR system. The dereplication method allowed the characterisation of four compounds (gigantol, imbricatin, methoxycoelonin and coelonin), previously isolated from Vanda coerulea stem extract. The analyses of two fractions permitted the identification of five additional minor constituents including one phenanthropyran, two phenanthrene and two dihydrophenanthrene derivatives. The full set of NMR data of each compound was obtained from microgram quantities. Nine secondary metabolites were characterised in A. rosea stems, utilising HPLC systems combined with high-resolution analytical systems. Two of them are newly described phenanthrene derivatives: aerosanthrene (5-methoxyphenanthrene-2,3,7-triol) and aerosin (3-methoxy-9,10-dihydro-2,5,7-phenanthrenetriol). Copyright © 2014 John Wiley & Sons, Ltd.

  10. The offline combination of thin-layer chromatography and high-performance liquid chromatography with diode array detection and micrOTOF-Q mass spectrometry for the separation and identification of spinochromes from sea urchin (Strongylocentrotus droebachiensis) shells.

    PubMed

    Shikov, Alexander N; Ossipov, Vladimir I; Martiskainen, Olli; Pozharitskaya, Olga N; Ivanova, Svetlana A; Makarov, Valery G

    2011-12-16

    Thin-layer chromatography (TLC) with off-line high-performance liquid chromatography coupled to diode array detection and micrOTOF-Q mass spectrometry (HPLC-DAD-MS) resulted in the successful fractionation, separation and identification of spinochrome pigments from sea urchin (Strongylocentrotus droebachiensis) shells. Two fractions of pigments were separated by TLC and eluted with methanol using a TLC-MS interface. HPLC-DAD-MS analysis of the fractions indicated the presence of six sea urchin pigments: spinochrome monomers B and D, three spinochrome dimers (anhydroethylidene-6,6'-bis(2,3,7-trihydroxynaphthazarin) and its isomer and ethylidene-6,6'-bis(2,3,7-trihydroxynaphthazarin)), and one pigment that was preliminary identified as a spinochrome dimer with the structural formula C(22)H(16)O(16). Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Screening of grapes and wine for azoxystrobin, kresoxim-methyl and trifloxystrobin fungicides by HPLC with diode array detection.

    PubMed

    De Melo Abreu, Susana; Correia, Manuela; Herbert, Paulo; Santos, Lúcia; Alves, Arminda

    2005-06-01

    The Quinone outside Inhibitors (QoI) are one of the most important and recent fungicide groups used in viticulture and also allowed by Integrated Pest Management. Azoxystrobin, kresoxim-methyl and trifloxystrobin are the main active ingredients for treating downy and powdery mildews that can be present in grapes and wines. In this paper, a method is reported for the analysis of these three QoI-fungicides in grapes and wine. After liquid-liquid extraction and a clean-up on commercial silica cartridges, analysis was by isocratic HPLC with diode array detection (DAD) with a run time of 13 min. Confirmation was by solid-phase micro-extraction (SPME), followed by GC/MS determination. The main validation parameters for the three compounds in grapes and wine were a limit of detection up to 0.073 mg kg(-1), a precision not exceeding 10.0% and an average recovery of 93% +/- 38.

  12. Determination of organophosphorus pesticides in bovine tissue by an on-line coupled matrix solid-phase dispersion-solid phase extraction-high performance liquid chromatography with diode array detection method.

    PubMed

    Gutiérrez Valencia, Tania M; García de Llasera, Martha P

    2011-09-28

    A miniaturized method based on matrix solid-phase dispersion coupled to solid phase extraction and high performance liquid chromatography with diode array detection (MSPD-SPE-HPLC/DAD) was developed for the trace simultaneous determination of the following organophosphorus pesticides (OPPs) in bovine tissue: parathion-methyl, fenitrothion, parathion, chlorfenvinphos, diazinon, ethion, fenchlorphos, chlorpyrifos and carbophenothion. To perform the coupling between MSPD and SPE, 0.05 g of sample was dispersed with 0.2 g of C(18) silica sorbent and packed into a stainless steel cartridge containing 0.05 g of silica gel in the bottom. After a clean-up of high and medium polarity interferences with water and an acetonitrile:water mixture, the OPPs were desorbed from the MSPD cartridge with pure acetonitrile and directly transferred to a dynamic mixing chamber for dilution with water and preconcentration into an SPE 20 mm × 2.0 mm I.D. C(18) silica column. Subsequently, the OPPs were eluted on-line with the chromatographic mobile phase to the analytical column and the diode array detector for their separation and detection, respectively. The method was validated and yielded recovery values between 91% and 101% and precision values, expressed as relative standard deviations (RSD), which were less than or equal to 12%. Linearity was good and ranged from 0.5 to 10 μg g(-1), and the limits of detection of the OPPs were in the range of 0.04-0.25 μg g(-1). The method was satisfactorily applied to the analysis of real samples and is recommended for food control, research efforts when sample amounts are limited, and laboratories that have ordinary chromatographic instrumentation. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. X-Ray Detector for 1 to 30 keV

    NASA Technical Reports Server (NTRS)

    Alcorn, G.; Jackson, J., Jr; Grant, P.; Marshall, F.

    1983-01-01

    Array of silicon X-ray detecting diodes measures photon energy and provides image of X-ray pattern. Regardless of thickness of new X-ray detector, depletion region extends through it. Impinging X-rays generate electrons in quantities proportional to X-ray energy. X-ray detector is mated to chargecoupled-device array for image generation and processing. Useful in industrial part inspection, pulsed-plasma research and medical application.

  14. Use of an online extraction liquid chromatography quadrupole time-of-flight tandem mass spectrometry method for the characterization of polyphenols in Citrus paradisi cv. Changshanhuyu peel.

    PubMed

    Tong, Chaoying; Peng, Mijun; Tong, Runna; Ma, Ruyi; Guo, Keke; Shi, Shuyun

    2018-01-19

    Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction of Citrus paradisi cv. Changshanhuyu (Changshanhuyu) peel, OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of twenty-two secondary metabolites were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and nine of them were discovered in Changshanhuyu peel for the first time to our knowledge. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Quantitative determination of flavonoids by column high-performance liquid chromatography with mass spectrometry and ultraviolet absorption detection in Artemisia afra and comparative studies with various species of Artemisia plants.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Mabusela, Wilfred; Vincent, Leszek; Weitz, Frans; Khan, Ikhlas A

    2009-01-01

    A simple and specific analytical method for the quantitative determination of flavonoids from the aerial parts of the Artemisia afra plant samples was developed. By column high-performance liquid chromatography (HPLC) with UV absorption and mass spectrometry (MS) detection, separation was achieved on a reversed-phase octadecylsilyl (C18) column with water, methanol, and acetonitrile, all containing 0.1% acetic acid, as the mobile phase. These methods were used to analyze various species of Artemisia plant samples. The wavelength used for quantification of flavonoids with the diode array detector was 335 nm. The limits of detection (LOD) by HPLC/MS were found to be 7.5, 7.5, 10, 2.0, and 2.0 ng/mL; and by LC-UV the LODs were 500, 500, 500, 300, and 300 ng/mL for apigenin, chrysoeriol, tamarixetin, acacetin, and genkwanin, respectively. The HPLC/MS method was found to be 50-150 times more sensitive than the HPLC-UV method. HPLC/MS coupled with an electrospray ionization interface is described for the identification and quantification of flavonoids in various plant samples. This method involved the use of the [M+H]+ ions of the compounds at mass-to-charge ratio of 1.0606, 301.0712, 317.0661, 285.0763, and 285.0763 (calculated mass), respectively, in the positive ion mode with extractive ion monitoring.

  16. Increasing Electrochemiluminescence Intensity of a Wireless Electrode Array Chip by Thousands of Times Using a Diode for Sensitive Visual Detection by a Digital Camera.

    PubMed

    Qi, Liming; Xia, Yong; Qi, Wenjing; Gao, Wenyue; Wu, Fengxia; Xu, Guobao

    2016-01-19

    Both a wireless electrochemiluminescence (ECL) electrode microarray chip and the dramatic increase in ECL by embedding a diode in an electromagnetic receiver coil have been first reported. The newly designed device consists of a chip and a transmitter. The chip has an electromagnetic receiver coil, a mini-diode, and a gold electrode array. The mini-diode can rectify alternating current into direct current and thus enhance ECL intensities by 18 thousand times, enabling a sensitive visual detection using common cameras or smart phones as low cost detectors. The detection limit of hydrogen peroxide using a digital camera is comparable to that using photomultiplier tube (PMT)-based detectors. Coupled with a PMT-based detector, the device can detect luminol with higher sensitivity with linear ranges from 10 nM to 1 mM. Because of the advantages including high sensitivity, high throughput, low cost, high portability, and simplicity, it is promising in point of care testing, drug screening, and high throughput analysis.

  17. A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2014-10-24

    A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7μm (150mm×2.1mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2mL/min, setting the wavelength at 262nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating method is suitable for the quality control of SR in new and commercial pharmaceutical formulations. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Rapid and quantitative determination of 10 major active components in Lonicera japonica Thunb. by ultrahigh pressure extraction-HPLC/DAD

    NASA Astrophysics Data System (ADS)

    Fan, Li; Lin, Changhu; Duan, Wenjuan; Wang, Xiao; Liu, Jianhua; Liu, Feng

    2015-01-01

    An ultrahigh pressure extraction (UPE)-high performance liquid chromatography (HPLC)/diode array detector (DAD) method was established to evaluate the quality of Lonicera japonica Thunb. Ten active components, including neochlorogenic acid, chlorogenic acid, 4-dicaffeoylquinic acid, caffeic acid, rutin, luteoloside, isochlorogenic acid B, isochlorogenic acid A, isochlorogenic acid C, and quercetin, were qualitatively evaluated and quantitatively determined. Scanning electron microscope images elucidated the bud surface microstructure and extraction mechanism. The optimal extraction conditions of the UPE were 60% methanol solution, 400 MPa of extraction pressure, 3 min of extraction time, and 1:30 (g/mL) solid:liquid ratio. Under the optimized conditions, the total extraction yield of 10 active components was 57.62 mg/g. All the components showed good linearity (r2 ≥ 0.9994) and recoveries. This method was successfully applied to quantify 10 components in 22 batches of L. japonica samples from different areas. Compared with heat reflux extraction and ultrasonic-assisted extraction, UPE can be considered as an alternative extraction technique for fast extraction of active ingredient from L. japonica.

  19. Mobility and persistence of the herbicide fomesafen in soils cultivated with bean plants using SLE/LTP and HPLC/DAD.

    PubMed

    Costa, Anna I G; Queiroz, Maria Eliana L R; Neves, Antônio A; de Assis, Roberta C; dos Soares, Carlos E S; da Silva, Antônio A; D'Antonino, Leonardo; de Oliveira, André F; Bellato, Carlos R

    2015-03-01

    A method has been optimized and validated for the determination of fomesafen in soils using solid-liquid extraction with low-temperature partitioning (SLE/LTP) and analysis by liquid chromatography with a high-efficiency diode array detector (HPLC/DAD). The method was used to evaluate the persistence and mobility of this herbicide in different soils cultivated with bean plants. Recovery values were ≥98.9 %, with variations in the repeatability coefficients of ≤15 %, and a detection limit of 7.3 μg kg(-1). Half-life values of fomesafen were between 60 and 71 days in soil cultivated using a no-till system and 99 and 114 days in soil cultivated using a conventional tillage system. The mobility of fomesafen was moderate and mainly influenced by the organic matter content, pH, and soil type. In Red-Yellow Argisol, which has a higher content of organic matter, the leaching of fomesafen was less pronounced. In Red-Yellow Latosol, which has smaller amounts of organic matter and high pH, the leaching of fomesafen was more pronounced.

  20. Fate of patulin in the presence of the yeast Saccharomyces cerevisiae.

    PubMed

    Moss, M O; Long, M T

    2002-04-01

    Patulin is known to become analytically non-detectable during the production of cider from contaminated apple juice. The fate of [14C]-labelled patulin during the alcoholic fermentation of apple juice was studied. Three commercial cider strains of Saccharomyces cerevisiae degraded patulin during active fermentative growth, but not when growing aerobically. The products of patulin degradation were more polar than patulin itself and remained in the clarified fermented cider. Patulin did not appear to bind to yeast cells or apple juice sediment in these model experiments. HPLC analysis of patulin-spiked fermentations showed the appearance of two major metabolites, one of which corresponded by both TLC and HPLC to E-ascladiol prepared by the chemical reduction of patulin using sodium borohydride. Using a diode array detector, both metabolites had a lambda(max) = 271 nm, identical to that of ascladiol. The nmr spectrum of a crude preparation of these metabolites showed signals corresponding to those of the E-ascladiol prepared chemically and a weaker set of signals corresponding to those reported in the literature for Z-ascladiol.

  1. Solid cation exchange phase to remove interfering anthocyanins in the analysis of other bioactive phenols in red wine.

    PubMed

    da Silva, Letícia Flores; Guerra, Celito Crivellaro; Klein, Diandra; Bergold, Ana Maria

    2017-07-15

    Bioactive phenols (BPs) are often targets in red wine analysis. However, other compounds interfere in the liquid chromatography methods used for this analysis. Here, purification procedures were tested to eliminate anthocyanin interference during the determination of 19 red-wine BPs. Liquid chromatography, coupled to a diode array detector (HPLC-DAD) and a mass spectrometer (UPLC-MS), was used to compare the direct injection of the samples with solid-phase extractions: reversed-phase (C18) and strong cation-exchange (SCX). The HPLC-DAD method revealed that, out of 13BPs, only six are selectively analyzed with or without C18 treatment, whereas SCX enabled the detection of all BPs. The recovery with SCX was above 86.6% for eight BPs. Moreover, UPLC-MS demonstrated the potential of SCX sample preparation for the determination of 19BPs. The developed procedure may be extended to the analysis of other red wine molecules or to other analytical methods where anthocyanins may interfere. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Multiresidue Screening Method for Detection of Benzimidazoles and their Metabolites in Liver and Muscle by High-Performance Liquid Chromatography: Method Development and Validation According to Commission Decision 2002/657/EC

    PubMed Central

    Prearo, Marino; Stella, Paola; Ostorero, Federica; Abete, Maria Cesarina

    2014-01-01

    The use of veterinary drugs may cause the presence of residues in food of animal origin if appropriate withdrawal periods are not respected. A high-performance liquid chromatography (HPLC) method has been developed for the simultaneous detection of 11 benzimidazole residues, including metabolites – albendazole, albendazole sulphoxide, albendazole sulphone, fenbendazole, fenbendazole sulphoxide (oxfendazole), fenbendazole sulphone, flubendazole, mebendazole, oxibendazole, thiabendazole, 5-hydroxythiabendazole – in bovine, ovine, equine, swine, rabbit and poultry liver and in bovine, swine and fish muscle. After extraction with a dicloromethane/acetonitrile solution (35/65 v/v) containing 5% ammonium hydroxide, the solvent was evaporated to dryness, the residue was dissolved in HCl 0.1 M, defatted with hexane, purified on a strong cation exchange solid-phase extraction cartridge and analysed in HPLC with diode array and fluorescence detectors. The method was validated as screening qualitative method evaluating, according to Commission Decision 2002/657/EC criteria, specificity, CCβ and β error at cut off level of 25 μg/kg and ruggedness. PMID:27800310

  3. Direct analysis of six antibiotics in wastewater samples using rapid high-performance liquid chromatography coupled with diode array detector: a chemometric study towards green analytical chemistry.

    PubMed

    Vosough, Maryam; Rashvand, Masoumeh; Esfahani, Hadi M; Kargosha, Kazem; Salemi, Amir

    2015-04-01

    In this work, a rapid HPLC-DAD method has been developed for the analysis of six antibiotics (amoxicillin, metronidazole, sulfamethoxazole, ofloxacine, sulfadiazine and sulfamerazine) in the sewage treatment plant influent and effluent samples. Decreasing the chromatographic run time to less than 4 min as well as lowering the cost per analysis, were achieved through direct injection of the samples into the HPLC system followed by chemometric analysis. The problem of the complete separation of the analytes from each other and/or from the matrix ingredients was resolved as a posteriori. The performance of MCR/ALS and U-PLS/RBL, as second-order algorithms, was studied and comparable results were obtained from implication of these modeling methods. It was demonstrated that the proposed methods could be used promisingly as green analytical strategies for detection and quantification of the targeted pollutants in wastewater samples while avoiding the more complicated high cost instrumentations. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A simple approach to quantitative analysis using three-dimensional spectra based on selected Zernike moments.

    PubMed

    Zhai, Hong Lin; Zhai, Yue Yuan; Li, Pei Zhen; Tian, Yue Li

    2013-01-21

    A very simple approach to quantitative analysis is proposed based on the technology of digital image processing using three-dimensional (3D) spectra obtained by high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD). As the region-based shape features of a grayscale image, Zernike moments with inherently invariance property were employed to establish the linear quantitative models. This approach was applied to the quantitative analysis of three compounds in mixed samples using 3D HPLC-DAD spectra, and three linear models were obtained, respectively. The correlation coefficients (R(2)) for training and test sets were more than 0.999, and the statistical parameters and strict validation supported the reliability of established models. The analytical results suggest that the Zernike moment selected by stepwise regression can be used in the quantitative analysis of target compounds. Our study provides a new idea for quantitative analysis using 3D spectra, which can be extended to the analysis of other 3D spectra obtained by different methods or instruments.

  5. Quality Analysis of Chlorogenic Acid and Hyperoside in Crataegi fructus

    PubMed Central

    Weon, Jin Bae; Jung, Youn Sik; Ma, Choong Je

    2016-01-01

    Background: Crataegi fructus is a herbal medicine for strong stomach, sterilization, and alcohol detoxification. Chlorogenic acid and hyperoside are the major compounds in Crataegi fructus. Objective: In this study, we established novel high-performance liquid chromatography (HPLC)-diode array detection analysis method of chlorogenic acid and hyperoside for quality control of Crataegi fructus. Materials and Methods: HPLC analysis was achieved on a reverse-phase C18 column (5 μm, 4.6 mm × 250 mm) using water and acetonitrile as mobile phase with gradient system. The method was validated for linearity, precision, and accuracy. About 31 batches of Crataegi fructus samples collected from Korea and China were analyzed by using HPLC fingerprint of developed HPLC method. Then, the contents of chlorogenic acid and hyperoside were compared for quality evaluation of Crataegi fructus. Results: The results have shown that the average contents (w/w %) of chlorogenic acid and hyperoside in Crataegi fructus collected from Korea were 0.0438% and 0.0416%, respectively, and the average contents (w/w %) of 0.0399% and 0.0325%, respectively. Conclusion: In conclusion, established HPLC analysis method was stable and could provide efficient quality evaluation for monitoring of commercial Crataegi fructus. SUMMARY Quantitative analysis method of chlorogenic acid and hyperoside in Crataegi fructus is developed by high.performance liquid chromatography.(HPLC).diode array detectionEstablished HPLC analysis method is validated with linearity, precision, and accuracyThe developed method was successfully applied for quantitative analysis of Crataegi fructus sample collected from Korea and China. Abbreviations used: HPLC: High-performance liquid chromatography, GC: Gas chromatography, MS: Mass spectrometer, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation, RRT: Relative retention time, RPA: Relation peak area. PMID:27076744

  6. Gas chromatography with simultaneous detection: Ultraviolet spectroscopy, flame ionization, and mass spectrometry.

    PubMed

    Gras, Ronda; Luong, Jim; Haddad, Paul R; Shellie, Robert A

    2018-05-08

    An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000 ppm (v/v) of less than 5% (n = 10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. MCT Detectors and ROICS for Various Format MWIR and LWIR Arrays

    DTIC Science & Technology

    2009-10-01

    ABSTRACT Silicon ROICs for MCT LWIR (4x288, 6x576) and MWIR (128x128) diode matrix arrays were designed, manufactured and tested. MCT layers...of polysilicon and two metallization levels. MCT Detectors and ROICs for Various Format MWIR and LWIR Arrays RTO-MP-SET-151 7 - 1...Format MWIR and LWIR Arrays 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f

  8. Quantitative Clinical Diagnostic Analysis of Acetone in Human Blood by HPLC: A Metabolomic Search for Acetone as Indicator

    PubMed Central

    Akgul Kalkan, Esin; Sahiner, Mehtap; Ulker Cakir, Dilek; Alpaslan, Duygu; Yilmaz, Selehattin

    2016-01-01

    Using high-performance liquid chromatography (HPLC) and 2,4-dinitrophenylhydrazine (2,4-DNPH) as a derivatizing reagent, an analytical method was developed for the quantitative determination of acetone in human blood. The determination was carried out at 365 nm using an ultraviolet-visible (UV-Vis) diode array detector (DAD). For acetone as its 2,4-dinitrophenylhydrazone derivative, a good separation was achieved with a ThermoAcclaim C18 column (15 cm × 4.6 mm × 3 μm) at retention time (t R) 12.10 min and flowrate of 1 mL min−1 using a (methanol/acetonitrile) water elution gradient. The methodology is simple, rapid, sensitive, and of low cost, exhibits good reproducibility, and allows the analysis of acetone in biological fluids. A calibration curve was obtained for acetone using its standard solutions in acetonitrile. Quantitative analysis of acetone in human blood was successfully carried out using this calibration graph. The applied method was validated in parameters of linearity, limit of detection and quantification, accuracy, and precision. We also present acetone as a useful tool for the HPLC-based metabolomic investigation of endogenous metabolism and quantitative clinical diagnostic analysis. PMID:27298750

  9. Validated RP-HPLC/DAD Method for the Quantification of Insect Repellent Ethyl 2-Aminobenzoate in Membrane-Moderated Matrix Type Monolithic Polymeric Device.

    PubMed

    Islam, Johirul; Zaman, Kamaruz; Chakrabarti, Srijita; Sharma Bora, Nilutpal; Mandal, Santa; Pratim Pathak, Manash; Srinivas Raju, Pakalapati; Chattopadhyay, Pronobesh

    2017-07-01

    A simple, accurate and sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the estimation of ethyl 2-aminobenzoate (EAB) in a matrix type monolithic polymeric device and validated as per the International Conference on Harmonization guidelines. The analysis was performed isocratically on a ZORBAX Eclipse plus C18 analytical column (250 × 4.4 mm, 5 μm) and a diode array detector (DAD) using acetonitrile and water (75:25 v/v) as the mobile phase by keeping the flow-rate constant at 1.0 mL/min. Determination of EAB was not interfered in the presence of excipients. Inter- and intra-day relative standard deviations were not higher than 2%. Mean recovery was between 98.7 and 101.3%. Calibration curve was linear in the concentration range of 0.5-10 µg/mL. Limits of detection and quantification were 0.19 and 0.60 µg/mL, respectively. Thus, the present report put forward a novel method for the estimation of EAB, an emerging insect repellent, by using RP-HPLC technique. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Development and Validation of an HPLC Method for Simultaneous Determination of Rifampicin, Isoniazid, Pyrazinamide, and Ethambutol Hydrochloride in Pharmaceutical Formulations.

    PubMed

    Chellini, Paula R; Lages, Eduardo B; Franco, Pedro H C; Nogueira, Fernando H A; César, Isabela C; Pianetti, Gerson A

    2015-01-01

    Tuberculosis treatment consists of a fixed dose combination of rifampicin (RIF), isoniazid (INH), pyrazinamide (PYZ), and ethambutol hydrochloride (EMB). The combined treatment using various drugs is necessary for patient curing, without recrudescence, and for prevention of drug-resistant mutants, which may occur during treatment. An HPLC-diode array detector (DAD) method for the simultaneous determination of RIF, INH, PYZ, and EMB in fixed dose combination tablets was developed and validated. Chromatographic experiments were performed on an Agilent 1200 HPLC system, and the separation was carried out on a Purospher STAR RP18e (250×4.6 mm id, 5 μm, Merck) analytical column. Gradient elution was carried out with a mobile phase of 20 mM monobasic sodium phosphate buffer with 0.2% triethylamine (pH 7.0) and acetonitrile at a flow rate of 1.5 mL/min. The total run time was 12 min, and the re-equilibration time was 5 min. EMB detection was performed at 210 nm, and RIF, INH, and PYZ were detected at 238 nm, using a DAD. The method proved to be specific, linear (r2>0.99), precise (RSD<2%), accurate, and robust and may be applied to the QC analysis of pharmaceutical formulations.

  11. Development and Validation of a Reliable and Robust Method for the Analysis of Cannabinoids and Terpenes in Cannabis.

    PubMed

    Giese, Matthew W; Lewis, Mark A; Giese, Laura; Smith, Kevin M

    2015-01-01

    The requirements for an acceptable cannabis assay have changed dramatically over the years resulting in a large number of laboratories using a diverse array of analytical methodologies that have not been properly validated. Due to the lack of sufficiently validated methods, we conducted a single- laboratory validation study for the determination of cannabinoids and terpenes in a variety of commonly occurring cultivars. The procedure involves high- throughput homogenization to prepare sample extract, which is then profiled for cannabinoids and terpenes by HPLC-diode array detector and GC-flame ionization detector, respectively. Spike recovery studies for terpenes in the range of 0.03-1.5% were carried out with analytical standards, while recovery studies for Δ9-tetrahydrocannabinolic acid, cannabidiolic acid, Δ9-tetrahydrocannabivarinic acid, and cannabigerolic acid and their neutral counterparts in the range of 0.3-35% were carried out using cannabis extracts. In general, accuracy at all levels was within 5%, and RSDs were less than 3%. The interday and intraday repeatabilities of the procedure were evaluated with five different cultivars of varying chemotype, again resulting in acceptable RSDs. As an example of the application of this assay, it was used to illustrate the variability seen in cannabis coming from very advanced indoor cultivation operations.

  12. Decontamination of chlorantraniliprole residues on cabbage and cauliflower through household processing methods.

    PubMed

    Kar, Abhijit; Mandal, Kousik; Singh, Balwinder

    2012-04-01

    A supervised field trial was conducted to study the residues of chlorantraniliprole on cabbage and cauliflower. Three applications of chlorantraniliprole at 10 days interval were made @ 9.25 and 18.50 g a.i. ha(-1). The samples of marketable size heads and curds of cabbage and cauliflower were collected at 0 and 1 day after the last application. QuEChERS sample preparation was used for the determination of chlorantraniliprole residues on cabbage heads and cauliflower curds. The residues of chlorantraniliprole were quantified by high performance liquid chromatography (HPLC) with photo diode array (PDA) detector and confirmed by high performance thin layer chromatography (HPTLC). Washing of cabbage and cauliflower with tap water removed about 17%-40% of chlorantraniliprole residues. However, boiling removed 100% of chlorantraniliprole residues on cabbage and cauliflower in both the cases.

  13. Simultaneous Determination of Four Compounds, Campesterol, Emodin8-O-β-D-Glucopyranoside, Quercetin, and Isoquercitrin in Reynoutria sachalinensis by High-performance Liquid Chromatography-Diode Array Detector

    PubMed Central

    Eom, Min Rye; Weon, Jin Bae; Jung, Youn Sik; Ryu, Ga Hee; Yang, Woo Seung; Ma, Choong Je

    2017-01-01

    Background: Reynoutria sachalinensis is a well-known and used herbal medicine to treatment of arthralgia, jaundice, amenorrhea, coughs, carbuncles, and sores. Objective: We have developed high-performance liquid chromatography analysis method for simultaneous determination of isolated four compounds, campesterol, emodin8-O-β-D-glucopyranoside, quercetin, and isoquercitrin from R. sachalinensis is. Materials and Methods: The four compounds were separated on Shiseido C18 column (S-5 μm, 4.6 mm I.D. ×250 mm) at a column temperature of 25°C. The mobile phase composed of water and methanol with gradient elution system, and flow rate is 1.0 ml/min. The detection wavelength was set at 205 nm. Results: Validation of this analytical method was evaluated by linearity, precision, and accuracy test. This established method had good linearity (R2 > 0.997). The relative standard deviation values of intra- and inter-day testing were indicated that <2%, and accuracy is 91.66%–103.31% at intraday and 91.69%–103.31% at intraday. The results of recovery test were 92.60%–108.99%. Conclusion: In these results, developed method was accurate and reliable to the quality evaluation of campesterol, emodin 8-O-β-D-glucopyranoside, quercetin, and isoquercitrin isolated from R. sachalinensis. SUMMARY We have developed high-performance liquid analysis method for simultaneous determination of 4 compounds of Reynoutria sachalinensis. Abbreviations used: HPLC: High-performance liquid chromatography, DAD: Diode array detector, LOD: Limit of detection, LOQ: Limit of quantitation, ICH: International Conference on Harmonisation. PMID:28808389

  14. Characterization of flavonoids in the extract of Sophora flavescens Ait. by high-performance liquid chromatography coupled with diode-array detector and electrospray ionization mass spectrometry.

    PubMed

    Zhang, Lei; Xu, Liang; Xiao, Shan-Shan; Liao, Qiong-Feng; Li, Qing; Liang, Jian; Chen, Xiao-Hui; Bi, Kai-Shun

    2007-09-03

    A method coupling high-performance liquid chromatography (HPLC) with diode-array detector (DAD) and electrospray ionization mass spectrometry (ESI) was established for the separation and characterization of flavonoids in Sophora flavescens Ait. Based on the chromatographic separation of most flavonoids present in S. flavescens Ait., a total of 24 flavonoids were identified. Fourteen compounds were unambiguously identified comparing experimental data for retention time (t(R)), UV and MS spectra with those of the authentic compounds: 3',7-dihydroxy-4'-methoxy-isoflavone (13), trifolirhizin (14), kurarinol (18), formononetin (19), 7,4'-dihydroxy-5-methoxy-8-(gamma,gamma-dimethylallyl)-flavanone (22), maackiain (21), isoxanthohumol (23), kuraridine (26), kuraridinol (27), sophoraflavanone G (30), xanthohumol (31), isokurarinone (33), kurarinone (35) and kushenol D (38), and additional 10 compounds were tentatively identified as kushenol O (10), trifolirhizin-6''-malonate (15), sophoraisoflavanone A (20), norkurarinol/kosamol Q (24), kushenol I/N (25), kushenol C (28), 2'-methoxykurarinone (29), kosamol R (32), kushecarpin A (34) and kushenol A (37) by comparing experimental data for UV and MS spectra with those of literature. Furthermore, fragmentation pathways in positive ions mode of 24 flavonoid compounds of types of flavanone, flavanonol, flavonol, chalcone, isoflavone, isoflavanone and ptercocarpane were summarized. Some common features, such as CH(3)., H(2)O, CO, CO(2), C(3)O(2) and C(2)H(2)O losses, together with Retro-Diels-Alder fragmentations were observed in the prenylated flavonoids in S. flavescens Ait. The loss of the lanandulyl chain was their characteristic fragmentation, which might help deducing the structure of unknown flavonoid compounds. The present study provided an approach to rapidly characterize bioactive constituents in S. flavescens Ait.

  15. Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats.

    PubMed

    Balla, Anusha; Cho, Kwan Hyung; Kim, Yu Chul; Maeng, Han-Joo

    2018-03-30

    A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N -acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi™ 4 µm polar, reversed-phase column using 1% acetic acid (pH 5.5) and methanol (76:24, v / v ) as eluent in isocratic mode at a flow rate 0.2 mL/min. The method showed good linearity ( r ² > 0.998) over the concentration range of 20-100,000 and 20-10,000 ng/mL for PA and NAPA, respectively. Intra- and inter-day accuracies ranged from 97.7 to 110.9%, and precision was <10.5% for PA and 99.7 to 109.2 and <10.5%, respectively, for NAPA. The lower limit of quantification was 20 ng/mL for both compounds. This is the first report of the UHPLC-DAD bioanalytical method for simultaneous measurement of PA and NAPA. The most obvious advantage of this method over previously reported HPLC methods is that it requires small sample and injection volumes, with a straightforward, one-step sample preparation. It overcomes the limitations of previous methods, which use large sample volume and complex sample preparation. The devised method was successfully applied to the quantification of PA and NAPA after an intravenous bolus administration of 10 mg/kg procainamide hydrochloride to rats.

  16. Characterization of active phenolic components in the ethanolic extract of Ananas comosus L. leaves using high-performance liquid chromatography with diode array detection and tandem mass spectrometry.

    PubMed

    Ma, Chao; Xiao, Sheng-yuan; Li, Zhen-guo; Wang, Wei; Du, Li-jun

    2007-09-21

    HPLC-DAD-MS was utilized to investigate the phytochemical constituents in ethanolic extract of Ananas comosus L. leaves (EEACL) responsible for antidiabetic, antihyperlipidemic and antioxidative effects. Eight phenylpropane diglycerides, together with two hydroxycinnamic acids, three hydroxycinnamoyl quinic acids, four phenylpropane monoglycerides, three flavones and six phenylpropanoid glycosides were detected, and their proposed structures were elucidated based on HPLC retention time, UV and MS profiles. Meanwhile, a new HPLC-DAD-MS method was established for the identification and characterization of phenylpropane diglycerides in natural plants.

  17. Stability and oxidation products of hydrolysable tannins in basic conditions detected by HPLC/DAD-ESI/QTOF/MS.

    PubMed

    Tuominen, Anu; Sundman, Terhi

    2013-01-01

    Hydrolysable tannins occur in plants that are used for food or medicine by humans or herbivores. Basic conditions can alter the structures of tannins, that is, the oxidation of phenolic groups can lead to the formation of toxic quinones. Previously, these labile quinones and other oxidation products have been studied with colorimetric or electron paramagnetic resonance methods, which give limited information about products. To study the stability and oxidation products of hydrolysable tannins in basic conditions using HPLC with a diode-array detector (DAD) combined with electrospray ionisation (ESI) and quadrupole time-of-flight (QTOF) MS. Three galloyl glucoses, four galloyl derivatives with different polyols and three ellagitannins were purified from plants. The incubation reactions of tannins were monitored by HPLC/DAD at five pH values and in reduced oxygen conditions. Reaction products were identified based on UV spectra and mass spectral fragmentation obtained with the high-resolution HPLC/DAD-ESI/QTOF/MS. The use of a base-resistant HPLC column enabled injections without the sample pre-treatment and thus detection of short-lived products. Hydrolysable tannins were unstable in basic conditions and half-lives were mostly less than 10 min at pH 10. Degradation rates were faster at pH 11 but slower at milder pH. The HPLC analyses revealed that various products were formed and identified to be the result of hydrolysis, deprotonation and oxidation. Interestingly, the main hydrolysis product was ellagic acid; it was also formed from galloyl glucoses that do not contain oxidatively coupled galloyl groups in their initial structures. HPLD/DAD-ESI/QTOF/MS was an efficient method for the identification of polyphenol oxidation products and showed how different pH conditions determine the fate of hydrolysable tannins. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Comparison of piracetam measured with HPLC-DAD, HPLC-ESI-MS, DIP-APCI-MS, and a newly developed and optimized DIP-ESI-MS.

    PubMed

    Lenzen, Claudia; Winterfeld, Gottfried A; Schmitz, Oliver J

    2016-06-01

    The direct inlet probe-electrospray ionization (DIP-ESI) presented here was based on the direct inlet probe-atmospheric pressure chemical ionization (DIP-APCI) developed by our group. It was coupled to an ion trap mass spectrometer (MS) for the detection of more polar compounds such as degradation products from pharmaceuticals. First, the position of the ESI tip, the gas and solvent flow rates, as well as the gas temperature were optimized with the help of the statistic program Minitab® 17 and a caffeine standard. The ability to perform quantitative analyses was also tested by using different concentrations of caffeine and camphor. Calibration curves with a quadratic calibration regression of R (2) = 0.9997 and 0.9998 for caffeine and camphor, respectively, were obtained. The limit of detection of 2.5 and 1.7 ng per injection for caffeine and camphor were determined, respectively. Furthermore, a solution of piracetam was used to compare established analytical methods for this drug and its impurities such as HPLC-diode array detector (DAD) and HPLC-ESI-MS with the DIP-APCI and the developed DIP-ESI. With HPLC-DAD and 10 μg piracetam on column, no impurity could be detected. With HPLC-ESI-MS, two impurities (A and B) were identified with only 4.6 μg piracetam on column, while with DIP-ESI, an amount of 1.6 μg piracetam was sufficient. In the case of the DIP-ESI measurements, all detected impurities could be identified by MS/MS studies. Graphical Abstract Scheme of the DIP-ESI principle.

  19. Antioxidant profiling of native Andean potato tubers (Solanum tuberosum L.) reveals cultivars with high levels of beta-carotene, alpha-tocopherol, chlorogenic acid, and petanin.

    PubMed

    Andre, Christelle M; Oufir, Mouhssin; Guignard, Cédric; Hoffmann, Lucien; Hausman, Jean-François; Evers, Danièle; Larondelle, Yvan

    2007-12-26

    The antioxidant profile of 23 native Andean potato cultivars has been investigated from a human nutrition perspective. The main carotenoid and tocopherol compounds were studied using high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD) and a fluorescence detector, respectively, whereas polyphenols (including anthocyanins in colored tubers) were identified by means of both HPLC-mass spectrometry and HPLC-DAD. Antioxidant profiling revealed significant genotypic variations as well as cultivars of particular interest from a nutritional point of view. Concentrations of the health-promoting carotenoids, lutein and zeaxanthin, ranged from 1.12 to 17.69 microg g(-1) of dry weight (DW) and from 0 to 17.7 microg g(-1) of DW, with cultivars 704353 and 702472 showing the highest levels in lutein and zeaxanthin, respectively. Whereas beta-carotene is rarely reported in potato tubers, remarkable levels of this dietary provitamin A carotenoid were detected in 16 native varieties, ranging from 0.42 to 2.19 microg g(-1) of DW. The amounts of alpha-tocopherol found in Andean potato tubers, extending from 2.73 to 20.80 microg g(-1) of DW, were clearly above the quantities generally reported for commercial varieties. Chlorogenic acid and its isomers dominated the polyphenolic profile of each cultivar. Dark purple-fleshed tubers from the cultivar 704429 contained exceptionally high levels of total anthocyanins (16.33 mg g(-1) of DW). The main anthocyanin was identified as petanin (petunidin-3-p-coumaroyl-rutinoside-5-glucoside). The results suggest that Andean potato cultivars should be exploited in screening and breeding programs for the development of potato varieties with enhanced health and nutritional benefits.

  20. Development and validation of a method for the simultaneous extraction and separate measurement of oxytetracycline, florfenicol, oxolinic acid and flumequine from marine sediments.

    PubMed

    Norambuena, Luis; Gras, Nuri; Contreras, Sergio

    2013-08-15

    A simple and rapid method for the detection and extraction of oxolinic acid, flumequine, florfenicol and oxytetracycline from marine sediments was developed and validated. The analytes were extracted from the marine sediment using a solution of oxalic acid diluted in methanol with sonication before detection by HPLC using a diode-array detector (florfenicol and oxytetracycline) and fluorescence (oxolinic acid and flumequine). The quantification limits (QL) were 100 ng/g for oxytetracycline and florfenicol and 5 ng/g for oxolinic acid and flumequine. The coefficients of variation of the repeatability and intermediate precision were less than 10% in all of the analytes. The calibration curves were linear between 50 and 500 ng/ml for oxytetracycline and florfenicol and 1 and 20 ng/ml for oxolinic acid and flumequine. The recuperation rate for the analytes was above 86%. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Determination of azoxystrobin and chlorothalonil using a methacrylate-based polymer modified with gold nanoparticles as solid-phase extraction sorbent.

    PubMed

    Catalá-Icardo, Mónica; Gómez-Benito, Carmen; Simó-Alfonso, Ernesto Francisco; Herrero-Martínez, José Manuel

    2017-01-01

    This paper describes a novel and sensitive method for extraction, preconcentration, and determination of two important widely used fungicides, azoxystrobin, and chlorothalonil. The developed methodology is based on solid-phase extraction (SPE) using a polymeric material functionalized with gold nanoparticles (AuNPs) as sorbent followed by high-performance liquid chromatography (HPLC) with diode array detector (DAD). Several experimental variables that affect the extraction efficiency such as the eluent volume, sample flow rate, and salt addition were optimized. Under the optimal conditions, the sorbent provided satisfactory enrichment efficiency for both fungicides, high selectivity and excellent reusability (>120 re-uses). The proposed method allowed the detection of 0.05 μg L -1 of the fungicides and gave satisfactory recoveries (75-95 %) when it was applied to drinking and environmental water samples (river, well, tap, irrigation, spring, and sea waters).

  2. Ultrasound-assisted analyte extraction for the determination of sulfate and elemental sulfur in zinc sulfide by different liquid chromatography techniques.

    PubMed

    Dash, K; Thangavel, S; Krishnamurthy, N V; Rao, S V; Karunasagar, D; Arunachalam, J

    2005-04-01

    The speciation and determination of sulfate (SO4(2-)) and elemental sulfur (S degree) in zinc sulfide (ZnS) using ion-chromatography (IC) and reversed-phase liquid chromatography (RPLC) respectively is described. Three sample pretreatment approaches were employed with the aim of determining sulfate: (i) conventional water extraction of the analyte; (ii) solid-liquid aqueous extraction with an ultrasonic probe; and (iii) elimination of the zinc sulfide matrix via ion-exchange dissolution (IED). The separation of sulfate was carried out by an anion-exchange column (IonPac AS17), followed by suppressed conductivity detection. Elemental sulfur was extracted ultrasonically from the acid treated sample solution into chloroform and separated on a reversed phase HPLC column equipped with a diode array detector (DAD) at 264 nm. The achievable solid detection limits for sulfate and sulfur were 35 and 10 microg g(-1) respectively.

  3. Chemical and biological comparison of the fruit extracts of Citrus wilsonii Tanaka and Citrus medica L.

    PubMed

    Zhao, Pan; Duan, Li; Guo, Long; Dou, Li-Li; Dong, Xin; Zhou, Ping; Li, Ping; Liu, E-Hu

    2015-04-15

    Citri Fructus (CF), the mature fruit of Citrus wilsonii Tanaka (CWT) or Citrus medica L. (CML), is an important citrus by-product with health promoting and nutritive properties. The present study compares the chemical and biological differences of CWT and CML. Thin layer chromatography and high performance liquid chromatography, coupled with quadrupole time-of-flight tandem mass spectrometry techniques, were employed to compare the chemical profiles of CWT and CML. A total of 25 compounds were identified and the results indicated that there were significant differences in chemical composition between the two CF species. The quantitative results obtained by HPLC coupled with diode array detector method demonstrated that naringin was present in the highest amounts in CWT, whilst nomilin was the most dominant constituent in CML. It was also found that CWT had significantly higher free radical-scavenging activity than CML. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Isolation and quantification of oligomeric pyranoanthocyanin-flavanol pigments from red wines by combination of column chromatographic techniques.

    PubMed

    He, Jingren; Santos-Buelga, Celestino; Mateus, Nuno; de Freitas, Victor

    2006-11-17

    A combination of column chromatography on Toyopearl gel HW-40 (S) and polyamide resin has been developed for the preparative isolation and further determination of pyranoanthocyanins of oligomeric nature formed after reaction between anthocyanins and different flavanols in a complex wine matrix. Polyamide chromatography was found to be exceptionally useful to separate oligomeric pyanoanthocyanins from other classes of wine flavonoids and polymerized pigments into an advanced state of purity for further identification and quantification by HPLC-diode array detector coupled with electrospray ionization mass spectrometry (HPLC-DAD/ESI-MS). Fractionation on Toyopearl gel chromatography allowed the separation of pyranoanthocyanins bearing the same flavanols (catechin, epicatechin and procyanidin dimers) but with different anthocyanin moieties (either acylated or non-acylated in the glucose residue) in order to allow further isolation of individual oligomeric pigments on C18 chromatography. A quantitative procedure for analyzing the major pyranoanthocyanin-flavanol derivatives in different aged wines is proposed for the first time. Results obtained showed good reproducibility and recovery regarding sample pretreatment and quantitative method for all analyzed oligomeric pyranoanthocyanins. The combination of these two chromatographic separations is likely to be applicable to the preparative isolation of other anthocyanin-derived pigments.

  5. Experimental design for extraction and quantification of phenolic compounds and organic acids in white "Vinho Verde" grapes.

    PubMed

    Dopico-García, M S; Valentão, P; Guerra, L; Andrade, P B; Seabra, R M

    2007-01-30

    An experimental design was applied for the optimization of extraction and clean-up processes of phenolic compounds and organic acids from white "Vinho Verde" grapes. The developed analytical method consisted in two steps: first a solid-liquid extraction of both phenolic compounds and organic acids and then a clean-up step using solid-phase extraction (SPE). Afterwards, phenolic compounds and organic acids were determined by high-performance liquid chromatography (HPLC) coupled to a diode array detector (DAD) and HPLC-UV, respectively. Plackett-Burman design was carried out to select the significant experimental parameters affecting both the extraction and the clean-up steps. The identified and quantified phenolic compounds were: quercetin-3-O-glucoside, quercetin-3-O-rutinoside, kaempferol-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin, kaempferol and epicatechin. The determined organic acids were oxalic, citric, tartaric, malic, shikimic and fumaric acids. The obtained results showed that the most important variables were the temperature (40 degrees C) and the solvent (acid water at pH 2 with 5% methanol) for the extraction step and the type of sorbent (C18 non end-capped) for the clean-up step.

  6. SU-E-I-107: Suitability of Various Radiation Detectors Used in Radiation Therapy for X-Ray Dosimetry in Computed Tomography.

    PubMed

    Liebmann, M; Poppe, B; von Boetticher, H

    2012-06-01

    Assessment of suitability for X-ray dosimetry in computed tomography of various ionization chambers, diodes and two-dimensional detector arrays primarily used in radiation therapy. An Oldelft X-ray simulation unit was used to irradiate PTW 60008, 60012 dosimetry diodes, PTW 23332, 31013, 31010, 31006 axial symmetrical ionization chambers, PTW 23343, 34001 plane parallel ionization chambers and PTW Starcheck and 2D-Array seven29 as well as a prototype Farmer chamber with a copper wall. Peak potential was varied from 50 kV up to 125 kV and beam qualities were quantified through half-value-layer measurements. Energy response was investigated free in air as well as in 2 cm depth in a solid water phantom and refers to a manufacturer calibrated PTW 60004 diode for kV-dosimetry. The thimble ionization chambers PTW 31010, 31013, the uncapsuled diode PTW 60012 and the PTW 2D-Array seven29 exhibit an energy response deviation in the investigated energy region of approximately 10% or lower thus proving good usability in X-ray dosimetry if higher spatial resolution is needed or rotational irradiations occur. It could be shown that in radiation therapy routinely used detectors are usable in a much lower energy region. The rotational symmetry is of advantage in computed tomography dosimetry and enables dose profile as well as point dose measurements in a suitable phantom for estimation of organ doses. Additional the PTW 2D-Array seven29 can give a quick overview of radiation fields in non-rotating tasks. © 2012 American Association of Physicists in Medicine.

  7. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans

    PubMed Central

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-01-01

    Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes. PMID:25830058

  8. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans.

    PubMed

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-03-01

    Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes.

  9. Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection.

    PubMed

    Pavlović, Dragana Mutavdžić; Ašperger, Danijela; Tolić, Dijana; Babić, Sandra

    2013-09-01

    This paper describes the development, optimization, and validation of a method for the determination of five pharmaceuticals from different therapeutic classes (antibiotics, anthelmintics, glucocorticoides) in water samples. Water samples were prepared using SPE and extracts were analyzed by HPLC with diode-array detection. The efficiency of 11 different SPE cartridges to extract the investigated compounds from water was tested in preliminary experiments. Then, the pH of the water sample, elution solvent, and sorbent mass were optimized. Except for optimization of the SPE procedure, selection of the optimal HPLC column with different stationary phases from different manufacturers has been performed. The developed method was validated using spring water samples spiked with appropriate concentrations of pharmaceuticals. Good linearity was obtained in the range of 2.4-200 μg/L, depending on the pharmaceutical with the correlation coefficients >0.9930 in all cases, except for ciprofloxacin (0.9866). Also, the method has revealed that low LODs (0.7-3.9 μg/L), good precision (intra- and interday) with RSD below 17% and recoveries above 98% for all pharmaceuticals. The method has been successfully applied to the analysis of production wastewater samples from the pharmaceutical industry. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harpool, K; De La Fuente Herman, T; Ahmad, S

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dosemore » verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.« less

  11. Salting-out assisted liquid-liquid extraction combined with capillary HPLC for the determination of sulfonylurea herbicides in environmental water and banana juice samples.

    PubMed

    Gure, Abera; Lara, Francisco J; Moreno-González, David; Megersa, Negussie; del Olmo-Iruela, Monsalud; García-Campaña, Ana M

    2014-09-01

    A salting-out assisted liquid-liquid extraction (SALLE) combined with capillary high performance liquid chromatography with diode array detector (capillary HPLC-DAD) was proposed for extraction and determination of residues of nine sulfonylurea herbicides (SUHs) in environmental water and banana juice samples. Various parameters affecting the extraction process such as the type and volume of the organic solvent, sample volume, type and amount of salt, pH of the sample and vortex time were optimized. Under optimum conditions, matrix matched calibration curves were established using river water and banana juice samples. Good linear relationships as well as low limits of detection, LODs (0.4-1.3 and 3-13 µg/L) and quantification, LOQs (1.3-4.3 and 10-43 µg/L) were obtained in water and banana juice samples, respectively. The precision (intra- and inter-day) of the peak areas expressed as relative standard deviations (%, RSD), at two concentration levels were below 10 % in both matrices. Recoveries obtained from spiked environmental waters (river water and groundwater) and banana juice samples, at two concentration levels, ranged from 72 to 115%. The results of the analysis revealed that the proposed SALLE-capillary HPLC method is simple, rapid, cheap and environmentally friendly, being successfully applicable for the determination of SUH residues in waters and banana juices. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Quality Evaluation of the Traditional Medicine Majun Mupakhi ELA via Chromatographic Fingerprinting Coupled with UHPLC-DAD-Quadrupole-Orbitrap-MS and the Antioxidant Activity In Vitro

    PubMed Central

    Reheman, Ayinuer; Ma, Qing Ling; Nijat, Dilaram; Abdulla, Rahima

    2018-01-01

    By merging a high-performance liquid chromatography diode array detector (HPLC-DAD) method with high-performance thin-layer chromatography (HPTLC), an assay was developed for chemical fingerprinting and quantitative analysis of traditional medicine Majun Mupakhi ELA (MME), and constituent compounds were identified using HPLC coupled with UHPLC-DAD-Quadrupole-Orbitrap-MS method. In addition, the antioxidant capacity of MME was assessed based on the ability of components to scavenge radicals using in vitro method. Using a HPLC-DAD method with HPTLC easily validated the chemical fingerprinting results and quantified three characteristic components, namely, gallic acid (1), daidzein (2), and icariin (3), in commercial MMEs. The three compounds presented excellent regression values (R2 = 0.9999) in the ranges of the test and the method recovery was in the range from 100.49% to 100.68%. The fingerprints had 27 common characteristic peaks, of which 13 were verified by rapid UHPLC-DAD-Q-Orbitrap-MS analysis. In vitro antioxidant assays rapidly assessed and contrasted antioxidant activity or the free radical scavenging activity of the main polyphenolic classes in MMEs, and the antioxidant capacity was mostly affected by the presence of gallic acid. Thus, this study establishes a powerful and meaningful approach for MME quality control and for assessing in vitro antioxidant activity. PMID:29692853

  13. Determination of Four Major Saponins in Skin and Endosperm of Seeds of Horse Chestnut (Aesculus Hippocastanum L.) Using High Performance Liquid Chromatography with Positive Confirmation by Thin Layer Chromatography.

    PubMed

    Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna

    2015-11-01

    To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized extraction conditions were: 70% methanol as extraction solvent, 80 °C as extraction temperature, and the extraction time was achieved in 4 hours. The HPLC conditions used: Zorbax SB-ODS-(150 mm × 2.1 mm, 3 μm) column, acetonitrile and 0.10% phosphoric acid solution (39:61 v/v) as mobile phase, flow rate was 0.5 mL min(-1) at 210 nm and 230 nm detection. The injection volume was 10 μL, and the separation was carried out isothermally at 30 °C in a heated chamber. The results indicated that the developed HPLC method is simple, sensitive and reliable. Moreover, the content of escins in seeds decreased by more than 30% in endosperm and by more than 40% in skin upon storage for two years. This assay can be readily utilized as a quality control method for horse chestnut and other related medicinal plants.

  14. Quality Evaluation of the Traditional Medicine Majun Mupakhi ELA via Chromatographic Fingerprinting Coupled with UHPLC-DAD-Quadrupole-Orbitrap-MS and the Antioxidant Activity In Vitro.

    PubMed

    Reheman, Ayinuer; Aisa, Haji Akber; Ma, Qing Ling; Nijat, Dilaram; Abdulla, Rahima

    2018-01-01

    By merging a high-performance liquid chromatography diode array detector (HPLC-DAD) method with high-performance thin-layer chromatography (HPTLC), an assay was developed for chemical fingerprinting and quantitative analysis of traditional medicine Majun Mupakhi ELA (MME), and constituent compounds were identified using HPLC coupled with UHPLC-DAD-Quadrupole-Orbitrap-MS method. In addition, the antioxidant capacity of MME was assessed based on the ability of components to scavenge radicals using in vitro method. Using a HPLC-DAD method with HPTLC easily validated the chemical fingerprinting results and quantified three characteristic components, namely, gallic acid (1), daidzein (2), and icariin (3), in commercial MMEs. The three compounds presented excellent regression values ( R 2 = 0.9999) in the ranges of the test and the method recovery was in the range from 100.49% to 100.68%. The fingerprints had 27 common characteristic peaks, of which 13 were verified by rapid UHPLC-DAD-Q-Orbitrap-MS analysis. In vitro antioxidant assays rapidly assessed and contrasted antioxidant activity or the free radical scavenging activity of the main polyphenolic classes in MMEs, and the antioxidant capacity was mostly affected by the presence of gallic acid. Thus, this study establishes a powerful and meaningful approach for MME quality control and for assessing in vitro antioxidant activity.

  15. Antioxidant properties and chemical characterization of Spanish Opuntia ficus-indica Mill. cladodes and fruits.

    PubMed

    Andreu, Lucía; Nuncio-Jáuregui, Nallely; Carbonell-Barrachina, Ángel A; Legua, Pilar; Hernández, Francisca

    2018-03-01

    Recent studies have demonstrated that consumption of Opuntia ficus-indica Mill. has an important positive health benefit, mainly due to antioxidant properties, which justifies this research. This study examined antioxidant activity, organic acid and sugar profile, total phenolic, and physicochemical characteristics of six O. ficus-indica cultivars growing in the Spanish Mediterranean. It should be noted that, in this study, both cladodes (young and adult) and fruits (peel and pulp) were analyzed. The antioxidant activity (2,2-azinobis (3-ethylbenzothiazoline-6-sulfonic acid) and 2,2-diphenyl-1-picrylhydrazyl methods) was higher in fruit peel than in cladodes. The young cladodes presented an important antioxidant activity by the ferric-reducing ability of plasma method as well as a higher total phenolic content (18.90 g gallic acid equivalent per kilogram). High-performance liquid chromatography (HPLC) with diode-array detector analysis revealed the absence of sucrose and the presence of glucose and fructose, which the values were higher in pulp fruits. HPLC with refractive index detector analysis showed that citric, malic, and succinic acids were the main organic acids in all cultivars, with a significant higher content in old cladodes. These investigations valorize O. ficus-indica fruits in comparison with cladodes. In general, this plant can be considered as an ingredient for the production of health-promoting food, highlighting mainly in the antioxidant activity and total polyphenols content found in young cladodes and peel fruits. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Identification of Three Kinds of Citri Reticulatae Pericarpium Based on Deoxyribonucleic Acid Barcoding and High-performance Liquid Chromatography-diode Array Detection-electrospray Ionization/Mass Spectrometry/Mass Spectrometry Combined with Chemometric Analysis

    PubMed Central

    Yu, Xiaoxue; Zhang, Yafeng; Wang, Dongmei; Jiang, Lin; Xu, Xinjun

    2018-01-01

    Background: Citri Reticulatae Pericarpium is the dried mature pericarp of Citrus reticulata Blanco which can be divided into “Chenpi” and “Guangchenpi.” “Guangchenpi” is the genuine Chinese medicinal material in Xinhui, Guangdong province; based on the greatest quality and least amount, it is most expensive among others. Hesperidin is used as the marker to identify Citri Reticulatae Pericarpium described in the Chinese Pharmacopoeia 2010. However, both “Chenpi” and “Guangchenpi” contain hesperidin so that it is impossible to differentiate them by measuring hesperidin. Objective: Our study aims to develop an efficient and accurate method to separate and identify “Guangchenpi” from other Citri Reticulatae Pericarpium. Materials and Methods: The genomic deoxyribonucleic acid (DNA) of all the materials was extracted and then the internal transcribed spacer 2 was amplified, sequenced, aligned, and analyzed. The secondary structures were created in terms of the database and website established by Jörg Schultz et al. High-performance liquid chromatography-diode array detection-electrospray Ionization/mass spectrometry (HPLC-DAD-ESI-MS)/MS coupled with chemometric analysis was applied to compare the differences in chemical profiles of the three kinds of Citri Reticulatae Pericarpium. Results: A total of 22 samples were classified into three groups. The results of DNA barcoding were in accordance with principal component analysis and hierarchical cluster analysis. Eight compounds were deduced from HPLC-DAD-ESI-MS/MS. Conclusions: This method is a reliable and effective tool to differentiate the three Citri Reticulatae Pericarpium. SUMMARY The internal transcribed spacer 2 regions and the secondary structure among three kinds of Citri Reticulatae Pericarpium varied considerablyAll the 22 samples were analyzed by high-performance liquid chromatography (HPLC) to obtain the chemical profilesPrincipal component analysis and hierarchical cluster analysis were used in the chemometric analysisdeoxyribonucleic acid barcoding and HPLC-diode array detection-electrospray ionization/mass spectrometry/MS coupled with chemometric analysis provided an accurate and strong proof to identify these three herbs. Abbreviations used: CTAB: Hexadecyltrimethylammonium bromide, DNA: Deoxyribonucleic acid, ITS2: Internal transcribed spacer 2, PCR: Polymerase chain reaction. PMID:29576703

  17. Detector and energy analyzer for energetic-hydrogen in beams and plasmas

    DOEpatents

    Bastasz, Robert J.; Hughes, Robert C.; Wampler, William R.

    1988-01-01

    A detector for detecting energetic hydrogen ions and atoms ranging in energy from about 1 eV up to 1 keV in an evacuated environment includes a Schottky diode with a palladium or palladium-alloy gate metal applied to a silicondioxide layer on an n-silicon substrate. An array of the energetic-hydrogen detectors having a range of energy sensitivities form a plasma energy analyzer having a rapid response time and a sensitivity for measuring fluxes of energetic hydrogen. The detector is sensitive to hydrogen and its isotopes but is insensitive to non-hydrogenic particles. The array of energetic-hydrogen detectors can be formed on a single silicon chip, with thin-film layers of gold metal applied in various thicknesses to successive detectors in the array. The gold layers serve as particle energy-filters so that each detector is sensitive to a different range of hydrogen energies.

  18. Detector and energy analyzer for energetic-hydrogen in beams and plasmas

    DOEpatents

    Bastasz, R.J.; Hughes, R.C.; Wampler, W.R.

    1988-11-01

    A detector for detecting energetic hydrogen ions and atoms ranging in energy from about 1 eV up to 1 keV in an evacuated environment includes a Schottky diode with a palladium or palladium-alloy gate metal applied to a silicon-dioxide layer on an n-silicon substrate. An array of the energetic-hydrogen detectors having a range of energy sensitivities form a plasma energy analyzer having a rapid response time and a sensitivity for measuring fluxes of energetic hydrogen. The detector is sensitive to hydrogen and its isotopes but is insensitive to non-hydrogenic particles. The array of energetic-hydrogen detectors can be formed on a single silicon chip, with thin-film layers of gold metal applied in various thicknesses to successive detectors in the array. The gold layers serve as particle energy-filters so that each detector is sensitive to a different range of hydrogen energies. 4 figs.

  19. Bioaccessibility of phenols in common beans (Phaseolus vulgaris L.) and iron (Fe) availability to Caco-2 cells

    USDA-ARS?s Scientific Manuscript database

    Samples of common and biofortified beans (Phaseolus vulgaris), both raw and cooked (autoclaved 120 deg C, 20 min) were analyzed for their polyphenol composition. Polyphenols were identified via HPLC-UV/diode array detection. Cooking favored the extraction of polyphenols without the need of a hydroly...

  20. Fragmentation study of iridoid glycosides including epimers by liquid chromatography-diode array detection/electrospray ionization mass spectrometry and its application in metabolic fingerprint analysis of Gardenia jasminoides Ellis.

    PubMed

    Zhou, Tingting; Liu, Hua; Wen, Jun; Fan, Guorong; Chai, Yifeng; Wu, Yutian

    2010-09-15

    A high-performance liquid chromatography-diode array detection/electrospray ionization mass spectrometry (HPLC-DAD/ESI-MS) method was applied to the characterization of ten iridoid glycosides in Gardenia jasminoides Ellis, a traditional Chinese medicine. During the process of structural elucidation, two groups of isomers including two epimers were structurally characterized and differentiated according to their distinctive fragmentation patterns which were closely related to their isomeric differentiations. Subsequently, the major compounds were purified by multi-dimensional chromatography and semi-preparative HPLC and the structure identification was confirmed with NMR techniques. The major fragmentation pathways of iridoid glycosides in Gardenia jasminoides Ellis obtained through the MS data were schemed systematically, which provided the best sensitivity and specificity for characterization of the iridoid glycosides especially the isomers so far. Based on the fragmentation patterns of iridoid glycosides concluded, seven major iridoid glycosides were characterized in rat plasma after intravenous administration of Gardenia jasminoides Ellis. Copyright 2010 John Wiley & Sons, Ltd.

  1. Characterization of weld (Reseda luteola L.) and spurge flax (Daphne gnidium L.) by high-performance liquid chromatography-diode array detection-mass spectrometry in Arraiolos historical textiles.

    PubMed

    Marques, Rita; Sousa, Micaela M; Oliveira, Maria C; Melo, Maria J

    2009-02-27

    The natural dyes, and dye sources, in two seventeenth century Arraiolos carpets from the National Museum of Machado de Castro were analysed by high-performance liquid chromatography with UV-vis diode array detection (HPLC-DAD) and HPLC-mass spectrometry (LC-MS). Weld (Reseda luteola L.), indigo and spurge flax (Daphne gnidium L.) were found to be the dye sources, in agreement with original dyeing recipes collected during the nineteenth century. In order to fully characterize the plant sources, LC-MS conditions were optimized with plant extracts and the chromatographic separation and mass detection were enhanced. Extraction of the dyes, in the Arraiolos carpet samples, was performed using mild conditions that avoid glycoside decomposition. For the blues a dimethylformamide solution proved to be efficient for indigotin recovery. For all the other colours, an improved mild extraction method (with oxalic acid, methanol, acetone and water) was used, enabling to obtain the full dye source fingerprint, namely the flavonoid glycosides in the yellow dyes.

  2. Identification and quantification of 5,6,7,8-tetrahydro-2-(2-phenylethyl)chromones in Chinese eaglewood by HPLC with diode array detection and MS.

    PubMed

    Li, Jun; Chen, Dong; Jiang, Yong; Zhang, Qian; Zhang, Liang; Tu, Peng-Fei

    2013-12-01

    A sensitive and reliable HPLC coupled with diode array detection and MS method was developed and validated for the first time to simultaneously identify and quantify eight characteristic 5,6,7,8-tetrahydro-2-(2-phenylethyl)chromones (THPECs) in Chinese eaglewood. Chromatographic separation was performed on a Zorbax SB C18 column with a gradient of acetonitrile/0.1% formic acid/water as the mobile phase. The MS fragmentation behavior of THPECs was characterized as the successive neutral loss of two molecules of H2 O ([M+H-18-18](+) ) and then two molecules of CO ([M+H-18-18-28-28](+) ), which could be used to differentiate Chinese eaglewood from counterfeits. Validation of the developed analytical method showed good linearity, satisfactory precision, and good recovery. The established method was successfully applied to the simultaneous determination of eight THPECs in ten batches of Chinese eaglewood, which could be used as a tool for the quality control of Chinese eaglewood. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Determination of patulin in fruit juices using HPLC-DAD and GC-MSD techniques.

    PubMed

    Moukas, Athanasios; Panagiotopoulou, Vasiliki; Markaki, Panagiota

    2008-08-15

    A high performance liquid chromatography with a diode-array detector (HPLC-DAD) and a gas chromatography with a mass spectrometer (GC-MSD) are described for the determination of patulin (PAT) in apple juice. The limits of detection (DL) and quantification (QL) for the HPLC-DAD and GC-MSD method were found to be (DL=0.23μgkg(-1) QL=1.2μgkg(-1)) and (DL=5.8μgkg(-1) and QL=13.8μgkg(-1)), respectively. The recovery factors for HPLC-DAD and GC-MSD were found to be 99.5% (RSD%=0.73) and 41% (RSD%=10.03), respectively. The HPLC-DAD method was used to determine the occurrence of PAT in 90 samples of fruit juices. Results revealed the presence of PAT in 100% of the samples examined. The mean values of PAT in concentrated fruit juices and in the commercial fruit juices collected from the Greek market were found to be 10.54μg PAT kg(-1) and 5.57μg PAT kg(-1) juice, respectively. The most contaminated samples were four concentrated juices ranging from 18.10μg PAT kg(-1) to 36.8μg PAT kg(-1) juice. The daily exposure to patulin for the consumers of all ages in Greece, is ranging from 0.008μg PAT kg(-1) bw to 0.1μg PAT kg(-1) bw if the daily intake of fruit juices is from 0.1 to 0.5kg. With the exception to the most contaminated sample, the daily exposure due to the samples examined, is below the provisional maximum tolerable daily intake for PAT (0.4μg PAT kg(-1) bw). Copyright © 2008 Elsevier Ltd. All rights reserved.

  4. Search for fullerenes in stone meteorites

    NASA Astrophysics Data System (ADS)

    Oester, M. Y.; Kuechl, D.; Sipiera, P. P.; Welch, C. J.

    1994-07-01

    The possibility of identifying fullerenes in stony meteorites became apparent from a paper given by Radicati de Brozolo. In this paper it was reported that fullerenes were present in the debris resulting from a collision between a micrometeoroid and an orbiting satellite. This fact generated sufficient curiosity to initiate a search for the presence of fullerenes in various stone meteorites. In the present study seven ordinary chondrites (al-Ghanim L6 (find), Dimmitt H4 (find), Lazbuddie LL5 (find), New Concord H5 (fall), Silverton H4 (find), Springlake L6 (find), and Umbarger L3/6 (find)). Four carbonaceous chondrites (ALH 83100 C2 (find), ALH 83108 C30 (find), Allende CV3 (fall), and Murchison CM2 (fall), and one achondrite (Monticello How (find)) were analyzed for the presence of fullerenes. The analytical procedure employed was as follows: 100 mg of meteorite was ground up with a mortar and pestle; 10 mL of toluene was then added and the mixture was refluxed for 90 min; this mixture was then filtered through a short column of silica; a 50 microliter sample was then analyzed by high pressure liquid chromatography (HPLC) using a Buckyclutcher I column with a mobile phase consisting of equal volumes of toluene and hexane at a flow rate of 1.00 mg per minute, with detection at 330 and 600 nm. Three of the meteorites, Allende, Murchison, and al-Ghanim, gave HPLC traces containing peaks with similar retention times to the HPLC trace of an authentic fullerene C60. However, further analysis using an HPLC instrument equipped with a diode-array detector failed to confirm any of the substances detected in the three meteorites as C60. Additional analyses will be conducted to identify what the HPLC traces actually represent.

  5. Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.

    PubMed

    Feygelman, Vladimir; Zhang, Geoffrey; Stevens, Craig; Nelms, Benjamin E

    2011-01-31

    We introduce a logical process of three distinct phases to begin the evaluation of a new 3D dosimetry array. The array under investigation is a hollow cylinder phantom with diode detectors fixed in a helical shell forming an "O" axial detector cross section (ArcCHECK), with comparisons drawn to a previously studied 3D array with diodes fixed in two crossing planes forming an "X" axial cross section (Delta⁴). Phase I testing of the ArcCHECK establishes: robust relative calibration (response equalization) of the individual detectors, minor field size dependency of response not present in a 2D predecessor, and uncorrected angular response dependence in the axial plane. Phase II testing reveals vast differences between the two devices when studying fixed-width full circle arcs. These differences are primarily due to arc discretization by the TPS that produces low passing rates for the peripheral detectors of the ArcCHECK, but high passing rates for the Delta⁴. Similar, although less pronounced, effects are seen for the test VMAT plans modeled after the AAPM TG119 report. The very different 3D detector locations of the two devices, along with the knock-on effect of different percent normalization strategies, prove that the analysis results from the devices are distinct and noninterchangeable; they are truly measuring different things. The value of what each device measures, namely their correlation with--or ability to predict--clinically relevant errors in calculation and/or delivery of dose is the subject of future Phase III work.

  6. Adapting Schottky Diode Detector Technology to a Space Platform

    DTIC Science & Technology

    1988-02-10

    the LWIR region) but which are still in a very early experimental stage. A schematic diagram illustrating the basic layout of the PtSi detector is...responsivity and dark current variations in pixels across the focal plane array. Such defects are caused by diverse factors such as nonuniformities in

  7. Robotic radiosurgery system patient-specific QA for extracranial treatments using the planar ion chamber array and the cylindrical diode array.

    PubMed

    Lin, Mu-Han; Veltchev, Iavor; Koren, Sion; Ma, Charlie; Li, Jinsgeng

    2015-07-08

    Robotic radiosurgery system has been increasingly employed for extracranial treatments. This work is aimed to study the feasibility of a cylindrical diode array and a planar ion chamber array for patient-specific QA with this robotic radiosurgery system and compare their performance. Fiducial markers were implanted in both systems to enable image-based setup. An in-house program was developed to postprocess the movie file of the measurements and apply the beam-by-beam angular corrections for both systems. The impact of noncoplanar delivery was then assessed by evaluating the angles created by the incident beams with respect to the two detector arrangements and cross-comparing the planned dose distribution to the measured ones with/without the angular corrections. The sensitivity of detecting the translational (1-3 mm) and the rotational (1°-3°) delivery errors were also evaluated for both systems. Six extracranial patient plans (PTV 7-137 cm³) were measured with these two systems and compared with the calculated doses. The plan dose distributions were calculated with ray-tracing and the Monte Carlo (MC) method, respectively. With 0.8 by 0.8 mm² diodes, the output factors measured with the cylindrical diode array agree better with the commissioning data. The maximum angular correction for a given beam is 8.2% for the planar ion chamber array and 2.4% for the cylindrical diode array. The two systems demonstrate a comparable sensitivity of detecting the translational targeting errors, while the cylindrical diode array is more sensitive to the rotational targeting error. The MC method is necessary for dose calculations in the cylindrical diode array phantom because the ray-tracing algorithm fails to handle the high-Z diodes and the acrylic phantom. For all the patient plans, the cylindrical diode array/ planar ion chamber array demonstrate 100% / > 92% (3%/3 mm) and > 96% / ~ 80% (2%/2 mm) passing rates. The feasibility of using both systems for robotic radiosurgery system patient-specific QA has been demonstrated. For gamma evaluation, 2%/2 mm criteria for cylindrical diode array and 3%/3 mm criteria for planar ion chamber array are suggested. The customized angular correction is necessary as proven by the improved passing rate, especially with the planar ion chamber array system.

  8. HPLC-DAD-ESI/MS identification of light harvesting and light screening pigments in the lake sediments at Edmonson Point.

    PubMed

    Giovannetti, Rita; Alibabaei, Leila; Zannotti, Marco; Ferraro, Stefano; Petetta, Laura

    2013-01-01

    The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC) with electrospray-mass spectrometry (ESI-MS) detection and diode array detection (DAD) has been used to identify light screening and light harvesting pigments. The results are discussed in terms of local environmental conditions.

  9. Simultaneous qualitative and quantitative analysis of phenolic acids and flavonoids for the quality control of Apocynum venetum L. leaves by HPLC-DAD-ESI-IT-TOF-MS and HPLC-DAD.

    PubMed

    An, Haijuan; Wang, Hong; Lan, Yuexiang; Hashi, Yuki; Chen, Shizhong

    2013-11-01

    A reliable method based on high performance liquid chromatography-diode array detector-electrospray ionization-ion trap-time of flight-mass spectrometry (HPLC-DAD-ESI-IT-TOF-MS) was developed for the identification of phenolic acids and flavonoids in Apocynum venetum L. leaves and its adulterant, Pocynum hendersonii (Hook. f.) Woodson leaves. A total of 21 compounds were identified or tentatively identified, including 4 phenolic acids and 17 flavonoids. 3-O-caffeoylquinic acid (3-CQA) and caffeic acid were detected for the first time in A. venetum leaves; 4-O-caffeoylquinic acid (4-CQA), 3-CQA, caffeic acid, quercetin-3-O-(6"-O-malonyl)-galactoside, quercetin-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-acetyl)-glucoside, and kaempferol-3-O-dihexoside were detected for the first time in P. hendersonii leaves. Cluster analysis was employed to analyze 24 batches of A. venetum leaves and 5 batches of P. hendersonii leaves collected from various regions in China. The analysis, which was based on the 21 compounds, indicated that profiles of these compounds were distinct between the two species, and among A. venetum leaf samples from different origins. 18 of these 21 compounds were selected as the markers and simultaneously analyzed by HPLC-DAD for the first time. The quantitative analytical method was validated and subsequently applied to the comprehensive quality evaluation of 24 batches of A. venetum leaves. © 2013 Elsevier B.V. All rights reserved.

  10. The bipolar silicon microstrip detector: A proposal for a novel precision tracking device

    NASA Astrophysics Data System (ADS)

    Horisberger, R.

    1990-03-01

    It is proposed to combine the technology of fully depleted silicon microstrip detectors fabricated on n doped high resistivity silicon with the concept of the bipolar transistor. This is done by adding a n ++ doped region inside the normal p + implanted region of the reverse biased p + n diode. Teh resulting structure has amplifying properties and is referred to as bipolar pixel transistor. The simplest readout scheme of a bipolar pixel array by an aluminium strip bus leads to the bipolar microstrip detector. The bipolar pixel structure is expected to give a better signal-to-noise performance for the detection of minimum ionizing charged particle tracks than the normal silicon diode strip detector and therefore should allow in future the fabrication of thinner silicon detectors for precision tracking.

  11. Performance parameters of a liquid filled ionization chamber array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poppe, B.; Stelljes, T. S.; Looe, H. K.

    2013-08-15

    Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluatedmore » using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.« less

  12. Cosmic Ray Measurements by Scintillators with Metal Resistor Semiconductor Avalanche Photo Diodes

    ERIC Educational Resources Information Center

    Blanco, Francesco; La Rocca, Paola; Riggi, Francesco; Akindinov, Alexandre; Mal'kevich, Dmitry

    2008-01-01

    An educational set-up for cosmic ray physics experiments is described. The detector is based on scintillator tiles with a readout through metal resistor semiconductor (MRS) avalanche photo diode (APD) arrays. Typical measurements of the cosmic angular distribution at sea level and a study of the East-West asymmetry obtained by such a device are…

  13. Modular multi-element high energy particle detector

    DOEpatents

    Coon, D.D.; Elliott, J.P.

    1990-01-02

    Multi-element high energy particle detector modules comprise a planar heavy metal carrier of tungsten alloy with planar detector units uniformly distributed over one planar surface. The detector units are secured to the heavy metal carrier by electrically conductive adhesive so that the carrier serves as a common ground. The other surface of each planar detector unit is electrically connected to a feedthrough electrical terminal extending through the carrier for front or rear readout. The feedthrough electrical terminals comprise sockets at one face of the carrier and mating pins projecting from the other face, so that any number of modules may be plugged together to create a stack of modules of any desired number of radiation lengths. The detector units each comprise four, preferably rectangular, p-i-n diode chips arranged around the associated feedthrough terminal to form a square detector unit providing at least 90% detector element coverage of the carrier. Integral spacers projecting from the carriers extend at least partially along the boundaries between detector units to space the p-i-n diode chips from adjacent carriers in a stack. The spacers along the perimeters of the modules are one-half the width of the interior spacers so that when stacks of modules are arranged side by side to form a large array of any size or shape, distribution of the detector units is uniform over the entire array. 5 figs.

  14. Modular multi-element high energy particle detector

    DOEpatents

    Coon, Darryl D.; Elliott, John P.

    1990-01-02

    Multi-element high energy particle detector modules comprise a planar heavy metal carrier of tungsten alloy with planar detector units uniformly distributed over one planar surface. The detector units are secured to the heavy metal carrier by electrically conductive adhesive so that the carrier serves as a common ground. The other surface of each planar detector unit is electrically connected to a feedthrough electrical terminal extending through the carrier for front or rear readout. The feedthrough electrical terminals comprise sockets at one face of the carrier and mating pins porjecting from the other face, so that any number of modules may be plugged together to create a stack of modules of any desired number of radiation lengths. The detector units each comprise four, preferably rectangular, p-i-n diode chips arranged around the associated feedthrough terminal to form a square detector unit providing at least 90% detector element coverage of the carrier. Integral spacers projecting from the carriers extend at least partially along the boundaries between detector units to space the p-i-n diode chips from adjacent carriers in a stack. The spacers along the perimeters of the modules are one-half the width of the interior spacers so that when stacks of modules are arranged side by side to form a large array of any size or shape, distribution of the detector units is uniform over the entire array.

  15. Fast and simultaneous determination of phenolic compounds and caffeine in teas, mate, instant coffee, soft drink and energetic drink by high-performance liquid chromatography using a fused-core column.

    PubMed

    Rostagno, M A; Manchón, N; D'Arrigo, M; Guillamón, E; Villares, A; García-Lafuente, A; Ramos, A; Martínez, J A

    2011-01-31

    A fast HPLC method with diode-array absorbance detector and fluorescence detector for the analysis of 19 phenolic acids, flavan-3-ols, flavones, flavonols and caffeine in different types of samples was developed. Using a C(18) reverse-phase fused-core column separation of all compounds was achieved in less than 5 min with an overall sample-to-sample time of 10 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity and peak symmetry. Limits of detection for all analyzed compounds ranged from 0.5 to 211 μg L(-1), while limits of quantitation ranged between 1.5 and 704 μg L(-1). The developed method was used for the determination of analytes present in different samples, including teas (black, white, green), mate, coffee, cola soft drink and an energetic drink. Concentration of the analyzed compounds occurring in the samples ranged from 0.4 to 314 mg L(-1). Caffeine was the analyte found in higher concentrations in all samples. Phytochemical profiles of the samples were consistent with those reported in the literature. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. "Characterization of ELEKTA SRS cone collimator using high spatial resolution monolithic silicon detector array".

    PubMed

    Shukaili, Khalsa Al; Corde, Stéphanie; Petasecca, Marco; Pereveratylo, Vladimir; Lerch, Michael; Jackson, Michael; Rosenfeld, Anatoly

    2018-05-22

    To investigate the accuracy of the dosimetry of radiation fields produced by small ELEKTA cone collimators used for stereotactic radiosurgery treatments (SRS) using commercially available detectors EBT3 Gafchromic TM film, IBA Stereotactic diode (SFD), and the recently developed detector DUO, which is a monolithic silicon orthogonal linear diode array detector. These three detectors were used for the measurement of beam profiles, output factors, and percentage depth dose for SRS cone collimators with cone sizes ranging from 5 to 50 mm diameter. The measurements were performed at 10 cm depth and 90 cm SSD. The SRS cone beam profiles measured with DUO, EBT3 film, and IBA SFD agreed well, results being in agreement within ±0.5 mm in the FWHM, and ±0.7 mm in the penumbra region. The output factor measured by DUO with 0.5 mm air gap above agrees within ±1% with EBT3. The OF measured by IBA SFD (corrected for the over-response) agreed with both EBT3 and DUO within ±2%. All three detectors agree within ±2% for PDD measurements for all SRS cones. The characteristics of the ELEKTA SRS cone collimator have been evaluated by using a monolithic silicon high spatial resolution detector DUO, EBT3, and IBA SFD diode. The DUO detector is suitable for fast real-time quality assurance dosimetry in small radiation fields typical for SRS/SRT. This has been demonstrated by its good agreement of measured doses with EBT 3 films. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  17. Characterization and identification of multiple constituents in Yinhuang granules by high-performance liquid chromatography with diode-array and time-of-flight mass spectrometry detection.

    PubMed

    Liu, E-Hu; Liu, Qun; Chu, Chu; Li, Ping

    2011-10-01

    A fast high-performance liquid chromatography (HPLC) method with diode-array detection (DAD) and time-of-flight mass spectrometry (TOF/MS) has been developed for the analysis of multi-constituent in Yinhuang granules, a well-known combined herbal remedy prepared from the extract mixtures of Flos Lonicerae and Radix Scutellariae. The fast HPLC analysis was performed on an Agilent ZorBax SB-C(18) column (4.6×50 mm, 1.8 μm) and 0.2% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution in 17 min, which is five times faster than the performance of conventional columns packed with 5.0 μm particles. With various fragmentor voltages in TOF/MS, accurate mass measurements (<5 ppm error) for molecular ions and characteristic fragment ions represented reliable identification criteria for different constituents. A total of 28 compounds, including nine phenolic acids, three iridoid glycosides and nine saponins from Flos Lonicerae and seven flavonoids from Radix Scutellariae, were identified or tentatively characterized in the extract of Yinhuang granules. The established fast HPLC-DAD-TOF/MS method turns out to be useful and efficient for quality control of this commonly used Chinese herbal preparation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A 2D silicon detector array for quality assurance in small field dosimetry: DUO.

    PubMed

    Shukaili, Khalsa Al; Petasecca, Marco; Newall, Matthew; Espinoza, Anthony; Perevertaylo, Vladimir L; Corde, Stéphanie; Lerch, Michael; Rosenfeld, Anatoly B

    2017-02-01

    Nowadays, there are many different applications that use small fields in radiotherapy treatments. The dosimetry of small radiation fields is not trivial due to the problems associated with lateral disequilibrium and source occlusion and requires reliable quality assurance (QA). Ideally such a QA tool should provide high spatial resolution, minimal beam perturbation and real time fast measurements. Many different types of silicon diode arrays are used for QA in radiotherapy; however, their application in small filed dosimetry is limited, in part, due to a lack of spatial resolution. The Center of Medical Radiation Physics (CMRP) has developed a new generation of a monolithic silicon diode array detector that will be useful for small field dosimetry in SRS/SRT. The objective of this study is to characterize a monolithic silicon diode array designed for dosimetry QA in SRS/SRT named DUO that is arranged as two orthogonal 1D arrays with 0.2 mm pitch. DUO is two orthogonal 1D silicon detector arrays in a monolithic crystal. Each orthogonal array contains 253 small pixels with size 0.04 × 0.8 mm 2 and three central pixels are with a size of 0.18 × 0.18 mm 2 each. The detector pitch is 0.2 mm and total active area is 52 × 52 mm 2 . The response of the DUO silicon detector was characterized in terms of dose per pulse, percentage depth dose, and spatial resolution in a radiation field incorporating high gradients. Beam profile of small fields and output factors measured on a Varian 2100EX LINAC in a 6 MV radiation fields of square dimensions and sized from 0.5 × 0.5 cm 2 to 5 × 5 cm 2 . The DUO response was compared under the same conditions with EBT3 films and an ionization chamber. The DUO detector shows a dose per pulse dependence of 5% for a range of dose rates from 2.7 × 10 -4 to 1.2 × 10 -4 Gy/pulse and 23% when the rate is further reduced to 2.8 × 10 -5 Gy/pulse. The percentage depth dose measured to 25 cm depth in solid water phantom beyond the surface and for a field size of 10 × 10 cm 2 agrees with that measured using a Markus IC within 1.5%. The beam profiles in both X and Y orthogonal directions showed a good match with EBT3 film, where the FWHM agreed within 1% and penumbra widths within 0.5 mm. The effect of an air gap above the DUO detector has also been studied. The output factor for field sizes ranging from 0.5 × 0.5 cm 2 to 5 × 5 cm 2 measured by the DUO detector with a 0.5 mm air gap above silicon surface agrees with EBT3 film and MOSkin detectors within 1.8%. The CMRP's monolithic silicon detector array, DUO, is suitable for SRS/SRT dosimetry and QA because of its very high spatial resolution (0.2 mm) and real time operation. © 2016 American Association of Physicists in Medicine.

  19. High-performance liquid chromatography (HPLC) as a tool for monitoring the fate of fluazinam in soil.

    PubMed

    Hakala, Kati P; Tuomainen, Päivi M; Yli-Halla, Markku J; Hartikainen, Helinä

    2014-01-01

    Fluazinam is a widely used pesticide employed against the fungal disease late blight in potato cultivation. A specific, repeatable, and rapid high-performance liquid chromatography (HPLC) method utilizing a diode array detector (DAD) was developed to determine the presence of fluazinam in soil. The method consists of acetonitrile (ACN) extraction, clean-up with solid-phase extraction (SPE), and separation using a mobile phase consisting of 70% ACN and 30% water (v/v), including 0.02% acetic acid. HPLC was performed with a C18 column and the detection wavelength was 240 nm. The method was successfully applied to an incubation experiment and to soil samples taken from potato fields where fluazinam had been applied two to three times during the on-going growing season. In the 90-day incubation experiment, analytical standard fluazinam and the commercial fungicide Shirlan(®) were added to soil samples that had never been treated with fluazinam, and were then extracted with ACN and 0.01 M calcium chloride (CaCl2). Fluazinam was not extractable with CaCl2, indicating that it does not leach to watercourses in the dissolved form. Recovery with ACN extraction for sandy soils was 72-95% immediately after application and 53-73% after 90 days of incubation. Out of the eight potato field soil samples, fluazinam was found in two samples at concentrations of 2.1 mg kg(-1) and 1.9 mg kg(-1), well above the limit of quantification (0.1 mg kg(-1)).

  20. Determination of Four Major Saponins in Skin and Endosperm of Seeds of Horse Chestnut (Aesculus Hippocastanum L.) Using High Performance Liquid Chromatography with Positive Confirmation by Thin Layer Chromatography

    PubMed Central

    Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna

    2015-01-01

    Purpose: To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). Methods: The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized extraction conditions were: 70% methanol as extraction solvent, 80 °C as extraction temperature, and the extraction time was achieved in 4 hours. The HPLC conditions used: Zorbax SB-ODS-(150 mm × 2.1 mm, 3 μm) column, acetonitrile and 0.10% phosphoric acid solution (39:61 v/v) as mobile phase, flow rate was 0.5 mL min−1 at 210 nm and 230 nm detection. The injection volume was 10 μL, and the separation was carried out isothermally at 30 °C in a heated chamber. Results: The results indicated that the developed HPLC method is simple, sensitive and reliable. Moreover, the content of escins in seeds decreased by more than 30% in endosperm and by more than 40% in skin upon storage for two years. Conclusion: This assay can be readily utilized as a quality control method for horse chestnut and other related medicinal plants. PMID:26819933

  1. An improved independent component analysis model for 3D chromatogram separation and its solution by multi-areas genetic algorithm.

    PubMed

    Cui, Lizhi; Poon, Josiah; Poon, Simon K; Chen, Hao; Gao, Junbin; Kwan, Paul; Fan, Kei; Ling, Zhihao

    2014-01-01

    The 3D chromatogram generated by High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD) has been researched widely in the field of herbal medicine, grape wine, agriculture, petroleum and so on. Currently, most of the methods used for separating a 3D chromatogram need to know the compounds' number in advance, which could be impossible especially when the compounds are complex or white noise exist. New method which extracts compounds from 3D chromatogram directly is needed. In this paper, a new separation model named parallel Independent Component Analysis constrained by Reference Curve (pICARC) was proposed to transform the separation problem to a multi-parameter optimization issue. It was not necessary to know the number of compounds in the optimization. In order to find all the solutions, an algorithm named multi-areas Genetic Algorithm (mGA) was proposed, where multiple areas of candidate solutions were constructed according to the fitness and distances among the chromosomes. Simulations and experiments on a real life HPLC-DAD data set were used to demonstrate our method and its effectiveness. Through simulations, it can be seen that our method can separate 3D chromatogram to chromatogram peaks and spectra successfully even when they severely overlapped. It is also shown by the experiments that our method is effective to solve real HPLC-DAD data set. Our method can separate 3D chromatogram successfully without knowing the compounds' number in advance, which is fast and effective.

  2. Rapid Identification and Assignation of the Active Ingredients in Fufang Banbianlian Injection Using HPLC-DAD-ESI-IT-TOF-MS.

    PubMed

    Li, Sensen; Lin, Zongtao; Jiang, Haixiu; Tong, Lingkun; Wang, Hong; Chen, Shizhong

    2016-08-01

    Fufang Banbianlian Injection (FBI) is a well-known traditional Chinese medicine formula composed of three herbal medicines. However, the systematic investigation on its chemical components has not been reported yet. In this study, a high-performance liquid chromatography combined with diode-array detector, and coupled to an electrospray ionization with ion-trap time-of-flight mass spectrometry (HPLC-DAD-ESI-IT-TOF-MS) method, was established for the identification of chemical profile in FBI. Sixty-six major constituents (14 phenolic acids, 14 iridoids, 20 flavonoids, 2 benzylideneacetone compounds, 3 phenylethanoid glycosides, 1 coumarin, 1 lignan, 3 nucleosides, 1 amino acids, 1 monosaccharides, 2 oligosaccharides, 3 alduronic acids and citric acid) were identified or tentatively characterized by comparing their retention times and MS spectra with those of standards or literature data. Finally, all constituents were further assigned in the individual herbs (InHs), although some of them were from multiple InHs. As a result, 11 compounds were from Lobelia chinensis Lour, 33 compounds were from Scutellaria barbata D. Don and 38 compounds were from Hedyotis diffusa Willd. In conclusion, the developed HPLC-DAD-ESI-IT-TOF-MS method is a rapid and efficient technique for analysis of FBI sample, and could be a valuable method for the further study on the quality control of the FBI. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Simultaneous determination of 15 marker constituents in various radix Astragali preparations by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Qi, Lian-Wen; Yu, Qing-Tao; Yi, Ling; Ren, Mei-Ting; Wen, Xiao-Dong; Wang, Yu-Xia; Li, Ping

    2008-01-01

    An improved quality control method was developed to simultaneously determine 15 major constituents (eight flavonoids and seven saponins) in various radix Astragali preparations, using SPE for pretreatment of samples, HPLC with diode-array and evaporative light scattering detectors (DAD-ELSD) for quantification in one run, and HPLC-ESI-TOF/MS for definite identification of compounds in preparations. Optimum separations were obtained with a ZORBAX C(18) column, using a gradient elution with 0.3% aqueous formic acid and ACN. This established method was fully validated with respect to linearity, precision, repeatability, and accuracy, and was successfully applied to quantify the 15 compounds in 19 commercial samples, including 3 dosage forms, i. e., oral solution, injection, concentrated granule, and its processed products of radix Astragali. The results demonstrated that many factors might result in significant differences in quality of the final preparations, including crude drugs, pretreatment processes, manufacturing procedure, storage conditions, etc. Then the developed method provided a reasonable and powerful manner to ensure the efficacy, safety, and batch-to-batch uniformity of radix Astragali products by standardizing each procedure, and thus should be proposed as quality control for the clinical use and modernization of herbal preparations.

  4. Reversed-phase HPLC analysis of levetiracetam in tablets using monolithic and conventional C18 silica columns.

    PubMed

    Can, Nafiz O; Arli, Goksel

    2010-01-01

    Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.

  5. Identification of candidate amino acids involved in the formation of blue pigments in crushed garlic cloves (Allium sativum L.).

    PubMed

    Cho, Jungeun; Lee, Eun Jin; Yoo, Kil Sun; Lee, Seung Koo; Patil, Bhimanagouda S

    2009-01-01

    The color-forming ability of amino acids with thiosulfinate in crushed garlic was investigated. We developed reaction systems for generating pure blue pigments using extracted thiosulfinate from crushed garlic and onion and all 22 amino acids. Each amino acid was reacted with thiosulfinate solution and was then incubated at 60 degrees C for 3 h to generate pigments. Unknown blue pigments, responsible for discoloration in crushed garlic cloves (Allium sativum L.), were separated and tentatively characterized using high-performance liquid chromatography (HPLC) and a diode array detector ranging between 200 and 700 nm. Blue pigment solutions exhibited 2 maximal absorbance peaks at 440 nm and 580 nm, corresponding to yellow and blue, respectively, with different retention times. Our findings indicated that green discoloration is created by the combination of yellow and blue pigments. Eight naturally occurring blue pigments were separated from discolored garlic extracts using HPLC at 580 nm. This suggests that garlic discoloration is not caused by only 1 blue pigment, as reported earlier, but by as many as 8 pigments. Overall, free amino acids that formed blue pigment when reacted with thiosulfinate were glycine, arginine, lysine, serine, alanine, aspartic acid, asparagine, glutamic acid, and tyrosine. Arginine, asparagine, and glutamine had spectra that were more similar to naturally greened garlic extract.

  6. Structural characterization of phenolics and betacyanins in Gomphrena globosa by high-performance liquid chromatography-diode array detection/electrospray ionization multi-stage mass spectrometry.

    PubMed

    Ferreres, Federico; Gil-Izquierdo, Angel; Valentão, Patrícia; Andrade, Paula B

    2011-11-30

    The metabolite profiling of Gomphrena globosa inflorescences was performed by high-performance liquid chromatography-diode array detection/electrospray ionization multi-stage mass spectrometry (HPLC-DAD/ESI-MS(n)). Based on the fragmentation patterns, 24 phenolic compounds were characterized. The identified phenolics include p-coumaric and ferulic acids, quercetin, kaempferol, isorhamnetin, and hydroxylated 6,7-methylenedioxyflavone derivatives, as well as their aglycones, none of them reported before in the species. This is also the first time that tetrahydroxy-methylenedioxyflavone derivatives and acetylglycosides are described in nature. Betacyanins were also found. This study significantly extends the knowledge of the G. globosa metabolome, by providing further insights into its phenolic composition. Copyright © 2011 John Wiley & Sons, Ltd.

  7. Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viel, Francis; Duzenli, Cheryl; British Columbia Cancer Agency, Department of Medical Physics, Vancouver Centre

    2014-08-15

    Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data andmore » a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.« less

  8. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

    PubMed

    Tate, Mark W; Purohit, Prafull; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2016-02-01

    We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

  9. 3D imaging LADAR with linear array devices: laser, detector and ROIC

    NASA Astrophysics Data System (ADS)

    Kameyama, Shumpei; Imaki, Masaharu; Tamagawa, Yasuhisa; Akino, Yosuke; Hirai, Akihito; Ishimura, Eitaro; Hirano, Yoshihito

    2009-07-01

    This paper introduces the recent development of 3D imaging LADAR (LAser Detection And Ranging) in Mitsubishi Electric Corporation. The system consists of in-house-made key devices which are linear array: the laser, the detector and the ROIC (Read-Out Integrated Circuit). The laser transmitter is the high power and compact planar waveguide array laser at the wavelength of 1.5 micron. The detector array consists of the low excess noise Avalanche Photo Diode (APD) using the InAlAs multiplication layer. The analog ROIC array, which is fabricated in the SiGe- BiCMOS process, includes the Trans-Impedance Amplifiers (TIA), the peak intensity detectors, the Time-Of-Flight (TOF) detectors, and the multiplexers for read-out. This device has the feature in its detection ability for the small signal by optimizing the peak intensity detection circuit. By combining these devices with the one dimensional fast scanner, the real-time 3D range image can be obtained. After the explanations about the key devices, some 3D imaging results are demonstrated using the single element key devices. The imaging using the developed array devices is planned in the near future.

  10. SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chacko, M; Aldoohan, S; Sonnad, J

    2015-06-15

    Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: Themore » dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.« less

  11. Characterization of constituents in Sini decoction and rat plasma by high-performance liquid chromatography with diode array detection coupled to time-of-flight mass spectrometry.

    PubMed

    Tan, Guangguo; Zhu, Zhenyu; Jing, Jing; Lv, Lei; Lou, Ziyang; Zhang, Guoqing; Chai, Yifeng

    2011-08-01

    A high-performance liquid chromatography with diode-array detection coupled to time-of-flight mass spectrometry (HPLC/DAD/TOFMS) method was established to clarify the chemical composition of Sini decoction (SND) and rat plasma after oral administration of SND. With dynamic adjustment of fragmentor voltage in TOFMS, an efficient transmission of the ions was achieved to obtain the best sensitivity for providing the molecular formula for each analyte and abundant fragment ions for structural information. By accurate mass measurements within 5 ppm error for each molecular ion and subsequent fragment ions, 53 compounds including diterpenoid alkaloids, flavonoids, triterpenoids and gingerol-related compounds were identified in SND. Major compounds identified from SND were further assigned in the three individual herbs. After oral administration of SND, 33 compounds and five metabolites in rat plasma were detected and identified by comparing and contrasting the compounds measured in SND with those in the plasma samples by HPLC/DAD/TOFMS. The results provided helpful chemical information for further pharmacology and active mechanism research on SND. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Identification and characterization of anthocyanins in yard-long beans (Vigna unguiculata ssp. sesquipedalis L.) by High-performance liquid chromatography with diode array detection and electrospray ionization/mass spectrometry (HPLC-DAD-ESI/MS) analysis.

    PubMed

    Ha, Tae Joung; Lee, Myoung-Hee; Park, Chang-Hwan; Pae, Suk-Bok; Shim, Kang-Bo; Ko, Jong-Min; Shin, Sang-Ouk; Baek, In-Youl; Park, Keum-Yong

    2010-02-24

    Anthocyanins play an important role in physiological functions related to human health. The objective of this study was to investigate the profiles of anthocyanins in the immature purple pods and black seeds of yard-long beans ( Vigna unguiculata ssp. sesquipedalis L.) using high-performance liquid chromatography (HPLC) with diode array detection and electrospray ionization/mass spectrometry (DAD-ESI/MS) analysis. The individual anthocyanins were identified by comparing their mass spectrometric data and retention times. In the purple pods, five individual anthocyanins were identified: delphinidin-3-O-glucoside (2), cyanidin-3-O-sambubioside (4), cyanidin-3-O-glucoside (5), pelargonidin-3-O-glucoside (7), and peonidin-3-O-glucoside (8). From the black seed coat of the yard-long beans, seven anthocyanins were identified, including delphinidin-3-O-galactoside (1), cyanidin-3-O-galactoside (3), petunidin-3-O-glucoside (6), and malvidin-3-O-glucoside (9), together with compounds 2, 5, and 8. In this study, we report for the first time anthocyanin profiles for the pod and seed coat of yard-long beans.

  13. Screening and analysis of the multiple absorbed bioactive components and metabolites in rat plasma after oral administration of Jitai tablets by high-performance liquid chromatography/diode-array detection coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Shu-Ping; Liu, Lei; Wang, Ling-Ling; Jiang, Peng; Zhang, Ji-Quan; Zhang, Wei-Dong; Liu, Run-Hui

    2010-06-15

    Based on the serum pharmacochemistry technique and high-performance liquid chromatography/diode-array detection (HPLC/DAD) coupled with electrospray tandem mass spectrometry (HPLC/ESI-MS/MS), a method for screening and analysis of the multiple absorbed bioactive components and metabolites of Jitai tablets (JTT) in orally dosed rat plasma was developed. Plasma was treated by methanol precipitation prior to liquid chromatography, and the separation was carried out on a Symmetry C(18) column, with a linear gradient (0.1% formic acid/water/acetonitrile). Mass spectra were acquired in negative and positive ion modes, respectively. As a result, 26 bioactive components originated from JTT and 5 metabolites were tentatively identified in orally dosed rat plasma by comparing their retention times and MS spectra with those of authentic standards and literature data. It is concluded that an effective and reliable analytical method was set up for screening the bioactive components of Chinese herbal medicine, which provided a meaningful basis for further pharmacology and active mechanism research of JTT. Copyright (c) 2010 John Wiley & Sons, Ltd.

  14. In Vitro Cultivars of Vaccinium corymbosum L. (Ericaceae) are a Source of Antioxidant Phenolics.

    PubMed

    Contreras, Rodrigo A; Köhler, Hans; Pizarro, Marisol; Zúiga, Gustavo E

    2015-04-09

    The antioxidant activity and phenolic composition of six in vitro cultured blueberry seedlings were determined. Extracts were prepared in 85% ethanol from 30 days old in vitro cultured plants and used to evaluate the antioxidant capacities that included Ferric reducing antioxidant power (FRAP) and 1,1-diphenyl-2-picrylhydrazin (DPPH•) scavenging ability, total polyphenols (TP) and the partial phenolic composition performed by high performance liquid chromatography with diode array detector (HPLC-DAD), liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (ESI-QqQ)). All ethanolic extracts from in vitro blueberry cultivars displayed antioxidant activity, with Legacy, Elliott and Bluegold cultivars being the most active. In addition, we observed a positive correlation between phenolic content and antioxidant activity. Our results suggest that the antioxidant activity of the extracts is related to the content of chlorogenic acid myricetin, syringic acid and rutin, and tissue culture of blueberry seedlings is a good tool to obtain antioxidant extracts with reproducible profile of compounds.

  15. Chemometric analysis for the evaluation of phenolic patterns in olive leaves from six cultivars at different growth stages.

    PubMed

    Talhaoui, Nassima; Gómez-Caravaca, Ana María; Roldán, Cristina; León, Lorenzo; De la Rosa, Raúl; Fernández-Gutiérrez, Alberto; Segura-Carretero, Antonio

    2015-02-18

    Leaves from six important olive cultivars grown under the same agronomic conditions were collected at four different times from June to December and analyzed by high performance liquid chromatography-diode array detector-time-of-flight-mass spectrometry (HPLC-DAD-TOF-MS). Twenty-eight phenolic compounds were identified and quantified. No qualitative differences were detected among leaves. However, for all cultivars, total concentrations of phenolic compounds decreased from June to August, then increased from October on, and reached higher levels again in December. Principal component analysis provided a clear separation of the phenolic content in leaves for different sampling times and cultivars. Hence, the availability of phenolic compounds depends on both the season and the cultivar. June and December seem to be good times to collect leaves as a source of phenolic compounds. December coincides with the harvest period of olives in the Andalusian region. Thus, in December olive leaves could be valorized efficiently as olive byproducts.

  16. [Simultaneous determination of aspartame and alitame in jellies and preserved fruits by HPLC].

    PubMed

    Jiang, Dingguo; Fang, Congrong; Yang, Dajin

    2012-05-01

    To establish a determination method for aspartame and alitame in jellies and preserved fruits. Aspartame and alitame in jellies were extracted with 80% methanol at 70 degrees C. Preserved fruits were homogenized with water and then were extracted with 50% methanol. A chromatographic column Zorbax SB-C18 was used; the mobile phase was methanol/water (40 + 60, volume ratio), and a diode array detector was used for the detection at wavelength 200 nm. The limits of quantification of aspartame and alitame were both 8 mg/kg for jellies and both 20 mg/kg for preserved fruits; the calibration curves were linear in the range of tested concentration. The correlation coefficients were better than 0.9996. The average recovery rates were in the range of 98.1% -101.2%, the relative standard deviations were 2.21% - 4.10%. The method is simple, practical, accurate, reliable and successful in the determination of aspartame and alitame in jellies and preserved fruits from various brands on markets.

  17. [Preparation of 1-(2-naphthyl) -3-methyl-5-pyrazolone as pre-column derivatization reagent for the determination of saccharides using high performance liquid chromatography-mass spectrometry].

    PubMed

    Sun, Zhiwei; Liu, Lingjun; Hu, Baojun; Sheng, Xiao; Wang, Xiaoyan; Suo, Yourui; You, Jinmao

    2008-03-01

    Eight saccharides were derivatized using 1-(2-naphthyl)-3-methyl-5-pyrazolone (NMP) as pre-column derivatizing reagent, and separated on a reversed-phase Hypersil ODS 2 column (4.6 mm x 200 mm, 5 microm), by high performance liquid chromatography (HPLC) in conjunction with a gradient elution, detected by a diode array detector (DAD), and identified by electrospray ionization-mass spectrometry (ESI-MS) in positive ion mode. NMP reacted with reductive saccharides easily in the presence of 17% ammonia water at 70 degrees C. All linear correlation coefficients for saccharide derivatives were over 0.998 5. The detection limits (at signal-to-noise of 3:1) were 0.58 - 1.1 pmol for saccharide derivatives. The characteristic fragment ions, especially m/z 473, from the cleavage of NMP-labeled saccharides exhibited high regularity for the identification of the composition of saccharide mixture. The established method is sensitive and repeatable for the determination of saccharides.

  18. In Vitro Cultivars of Vaccinium corymbosum L. (Ericaceae) are a Source of Antioxidant Phenolics

    PubMed Central

    Contreras, Rodrigo A.; Köhler, Hans; Pizarro, Marisol; Zúñiga, Gustavo E.

    2015-01-01

    The antioxidant activity and phenolic composition of six in vitro cultured blueberry seedlings were determined. Extracts were prepared in 85% ethanol from 30 days old in vitro cultured plants and used to evaluate the antioxidant capacities that included Ferric reducing antioxidant power (FRAP) and 1,1-diphenyl-2-picrylhydrazin (DPPH•) scavenging ability, total polyphenols (TP) and the partial phenolic composition performed by high performance liquid chromatography with diode array detector (HPLC-DAD), liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (ESI-QqQ)). All ethanolic extracts from in vitro blueberry cultivars displayed antioxidant activity, with Legacy, Elliott and Bluegold cultivars being the most active. In addition, we observed a positive correlation between phenolic content and antioxidant activity. Our results suggest that the antioxidant activity of the extracts is related to the content of chlorogenic acid myricetin, syringic acid and rutin, and tissue culture of blueberry seedlings is a good tool to obtain antioxidant extracts with reproducible profile of compounds. PMID:26783705

  19. Ultrasonic accelerates asparagine-glucose non-enzymatic browning reaction without acrylamide formation.

    PubMed

    Gao, Zhiqiang; Zheng, Junfeng; Chen, Lian

    2017-01-01

    Ultrasonic accelerated the asparagine-glucose non-enzymatic browning reaction with significant decrease of glucose and asparagine concentrations, and marked increase of intermediate products (UV-absorbance value at 294nm, Abs 294 ), melanoidins (UV-absorbance value at 420nm, Abs 420 ) and in vitro antioxidant activity (DPPH free radical scavenging activity). As the ultrasonic intensity was 17.83W/cm 2 , the asparagine-glucose solution's Abs 294 , Abs 420 and antioxidant activity increased from 0 to 1.26, 0.88 and 21.56%, respectively, and the glucose and asparagine concentrations of the asparagine-glucose solution reduced 58.97 and 12.57%, respectively. The high performance liquid chromatography (HPLC)-Diode Array Detector (DAD) analyses showed that no acrylamide was detected after 50-min ultrasonic reaction. This study suggested that ultrasonic at higher intensity was a potential method to accelerate the non-enzymatic browning reaction in the asparagine-glucose solution without acrylamide production. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Structural characterization and identification of biflavones in Selaginella tamariscina by liquid chromatography-diode-array detection/electrospray ionization tandem mass spectrometry.

    PubMed

    Zhang, Yi-Xuan; Li, Qiu-Yue; Yan, Li-Li; Shi, Yue

    2011-08-15

    Biflavonoids, a special class of flavonoids, are widely distributed in gymnosperm plants and have various biological activities. They are also major bioactive ingredients in Selaginella tamariscina. In this work, we report the use of high-performance liquid chromatography with a diode-array detector (HPLC-DAD) and electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) to study the fragmentation behavior of three main types of biflavonoids using seven biflavonoid reference compounds and analyze the biflavonoids in Selaginella tamariscina. The most useful fragmentations in terms of structural identification are those involving the C-ring cleavage of biflavonoids. For amentoflavone-type biflavonoids (containing flavonoid parts I and II), fragmentation on the flavonoid part II at positions 1/3 and 0/4 are the primary pathways, whereas the chances are greater for C-ring cleavage fragmentation occurring on flavonoid part I at positions 1/3 and 1/4 for robustaflavone-type biflavonoids. However, the predominant diagnostic ions of the specific C-O-C-connected hinokiflavone-type biflavonoids are a series of ions resulting from the rupture of the connective C-O bond. Based on the fragmentation patterns of these reference compounds, 17 biflavonoids were identified in an extract of Selaginella tamariscina, three of which have not been previously reported as constituents of this plant. This study provides a powerful approach for the online structural elucidation and identification of different types of biflavonoids and positional isomers from Selaginella tamariscina and other biflavonoids distributed in related plants and prescriptions. Copyright © 2011 John Wiley & Sons, Ltd.

  1. HPLC determination of flavonoid glycosides in Mongolian Dianthus versicolor Fisch. (Caryophyllaceae) compared with quantification by UV spectrophotometry.

    PubMed

    Obmann, Astrid; Purevsuren, Sodnomtseren; Zehl, Martin; Kletter, Christa; Reznicek, Gottfried; Narantuya, Samdan; Glasl, Sabine

    2012-01-01

    Dianthus versicolor is used in traditional Mongolian medicine against liver impairment. Fractions enriched in flavone-di- and triglycosides were shown to enhance bile secretion. Therefore, reliable and accurate analytical methods are needed for the determination of these flavonoids in the crude drug and extracts thereof. To provide a validated HPLC-DAD (diode array detector) method especially developed for the separation of polar flavonoids and to compare the data obtained with those evaluated by UV spectrophotometry. Separations were carried out on an Aquasil® C₁₈-column (4.6 mm × 250.0 mm, 5 µm) with a linear gradient of acetonitrile and water (adjusted to pH 2.8 with trifluoroacetic acid) as mobile phase. Rutoside was employed as internal standard with linear behavior in a concentration range of 0.007-3.5 mg/mL. Accuracy was determined by spiking the crude drug with saponarin resulting in recoveries between 92% and 102%. The method allows the quantification of highly polar flavonoid glycosides and the determination of their total content. For saponarin a linear response was evaluated within the range 0.007-3.5 mg/mL (R²  > 0.9999). It was proven that threefold sonication represents a time-saving, effective and cheap method for the extraction of the polar flavonoid glycosides. The contents determined by HPLC were shown to be in agreement with those obtained employing UV spectrophotometry. The study has indicated that the newly developed HPLC method represents a powerful technique for the quality control of D. versicolor. Ultraviolet spectrophotometry may be used alternatively provided that the less polar flavonoids are removed by purification. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Liquid chromatography with diode array detection combined with spectral deconvolution for the analysis of some diterpene esters in Arabica coffee brew.

    PubMed

    Erny, Guillaume L; Moeenfard, Marzieh; Alves, Arminda

    2015-02-01

    In this manuscript, the separation of kahweol and cafestol esters from Arabica coffee brews was investigated using liquid chromatography with a diode array detector. When detected in conjunction, cafestol, and kahweol esters were eluted together, but, after optimization, the kahweol esters could be selectively detected by setting the wavelength at 290 nm to allow their quantification. Such an approach was not possible for the cafestol esters, and spectral deconvolution was used to obtain deconvoluted chromatograms. In each of those chromatograms, the four esters were baseline separated allowing for the quantification of the eight targeted compounds. Because kahweol esters could be quantified either using the chromatogram obtained by setting the wavelength at 290 nm or using the deconvoluted chromatogram, those compounds were used to compare the analytical performances. Slightly better limits of detection were obtained using the deconvoluted chromatogram. Identical concentrations were found in a real sample with both approaches. The peak areas in the deconvoluted chromatograms were repeatable (intraday repeatability of 0.8%, interday repeatability of 1.0%). This work demonstrates the accuracy of spectral deconvolution when using liquid chromatography to mathematically separate coeluting compounds using the full spectra recorded by a diode array detector. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tim Roney; Robert Seifert; Bob Pink

    2011-09-01

    The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integrationmore » into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.« less

  4. Insights in the analytical performance of neat metal-organic frameworks in the determination of pollutants of different nature from waters using dispersive miniaturized solid-phase extraction and liquid chromatography.

    PubMed

    Rocío-Bautista, Priscilla; Pino, Verónica; Pasán, Jorge; López-Hernández, Irene; Ayala, Juan H; Ruiz-Pérez, Catalina; Afonso, Ana M

    2018-03-01

    Five metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5(Zn), MIL-53(Al), UiO-64 and MOF-74(Zn) are synthesized, characterized, and utilized in a miniaturized solid-phase extraction method under dispersive mode (D-µSPE) for the determination of six pollutants of different nature, including one polycyclic aromatic hydrocarbon, two hormones, two drugs, and one disinfectant, from environmental waters (tap water and wastewater). A discussion of possible interactions justifying the partitioning of target analytes to the MOFs is included, considering not only the analytes' physicochemical characteristics but also those of MOFs: metal nature, structural environment of MOF pores, pore size and pore aperture widths, among others. MIL-53(Al) is selected for its versatility and high extraction efficiency for the target compounds. The D-µSPE method using MIL-53(Al) is optimized and used in combination with high-performance liquid chromatography (HPLC) with diode array detector (DAD) or liquid-chromatography with time-of-flight mass spectrometric detector (LC-TOF). Under optimum conditions, only 5mg of MIL-53(Al) are required for 10mL of water, with the aid of 5min of vortex and 5min of centrifugation. Elution is accomplished with 200µL of acetonitrile (3 times), and evaporation down to 100µL before LC injection. Detection limits down to 0.040μgL -1 for triclosan and 0.013μgL -1 for atrazine are obtained for the entire method using HPLC-DAD and LC-TOF, respectively. The method, operating at low spiked levels (2µgL -1 for HPLC-DAD and 0.7µgL -1 for LC-TOF), is also characterized for average relative recoveries of 109% and 105%; relative standard deviation values lower than 8.7% and 7.5%; and average extraction efficiencies of 41.2% and 49.1%; using HPLC-DAD and LC-TOF, respectively; while demonstrating adequate analytical performance with complex samples such as wastewaters. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simultaneous quantitation of 14 active components in Yinchenhao decoction with an ultrahigh performance liquid chromatography-diode array detector: Method development and ingredient analysis of different commonly prepared samples.

    PubMed

    Yi, YaXiong; Zhang, Yong; Ding, Yue; Lu, Lu; Zhang, Tong; Zhao, Yuan; Xu, XiaoJun; Zhang, YuXin

    2016-11-01

    J. Sep. Sci. 2016, 39, 4147-4157 DOI: 10.1002/jssc.201600284 Yinchenhao decoction (YCHD) is a famous Chinese herbal formula recorded in the Shang Han Lun which was prescribed by Zhongjing Zhang during 150-219 AD. A novel quantitative analysis method was developed, based on ultrahigh performance liquid chromatography coupled with a diode array detector for the simultaneous determination of 14 main active components in Yinchenhao decoction. Furthermore, the method has been applied for compositional difference analysis of the 14 components in eight normal extraction samples of Yinchenhao decoction, with the aid of hierarchical clustering analysis and similarity analysis. The present research could help hospital, factory and lab choose the best way to make Yinchenhao decoction with better efficacy. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Deep diode arrays for X-ray detection

    NASA Technical Reports Server (NTRS)

    Zemel, J. N.

    1984-01-01

    Temperature gradient zone melting process was used to form p-n junctions in bulk of high purity silicon wafers. These diodes were patterned to form arrays for X-ray spectrometers. The whole fabrication processes for these X-ray detectors are reviewed in detail. The p-n junctions were evaluated by (1) the dark diode I-V measurements, (2) the diode C sub I - V measurements, and (3) the MOS C-V measurements. The results showed that these junctions were linearly graded in charge distribution with low reverse bias leakage current flowing through them (few nA at -10 volts). The X-ray detection experiments showed that an FWHM of 500 eV was obtained from these diodes with a small bias of just -5 volts (for X-ray source Fe55). A theoretical model was proposed to explain the extra peaks found in the energy spectra and a very interesting point - cross talk effect was pointed out. This might be a solution to the problem of making really high resolution X-ray spectrometers.

  7. A handheld laser-induced fluorescence detector for multiple applications.

    PubMed

    Fang, Xiao-Xia; Li, Han-Yang; Fang, Pan; Pan, Jian-Zhang; Fang, Qun

    2016-04-01

    In this paper, we present a compact handheld laser-induced fluorescence (LIF) detector based on a 450 nm laser diode and quasi-confocal optical configuration with a total size of 9.1 × 6.2 × 4.1 cm(3). Since there are few reports on the use of 450 nm laser diode in LIF detection, especially in miniaturized LIF detector, we systematically investigated various optical arrangements suitable for the requirements of 450 nm laser diode and system miniaturization, including focusing lens, filter combination, and pinhole, as well as Raman effect of water at 450 nm excitation wavelength. As the result, the handheld LIF detector integrates the light source (450 nm laser diode), optical circuit module (including a 450 nm band-pass filter, a dichroic mirror, a collimating lens, a 525 nm band-pass filter, and a 1.0mm aperture), optical detector (miniaturized photomultiplier tube), as well as electronic module (including signal recording, processing and displaying units). This detector is capable of working independently with a cost of ca. $2000 for the whole instrument. The detection limit of the instrument for sodium fluorescein solution is 0.42 nM (S/N=3). The broad applicability of the present system was demonstrated in capillary electrophoresis separation of fluorescein isothiocyanate (FITC) labeled amino acids and in flow cytometry of tumor cells as an on-line LIF detector, as well as in droplet array chip analysis as a LIF scanner. We expect such a compact LIF detector could be applied in flow analysis systems as an on-line detector, and in field analysis and biosensor analysis as a portable universal LIF detector. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The performance of Geiger mode avalanche photo-diodes in free space laser communication links

    NASA Astrophysics Data System (ADS)

    Farrell, Thomas C.

    2018-05-01

    Geiger mode avalanche photo-diode (APD) arrays, when used as detectors in laser communication (lasercom) receivers, promise better performance at lower signal levels than APDs operated in the linear mode. In this paper, we describe the basic operation of the Geiger mode APD array as a lasercom detector, concentrating on aspects relevant to the link design engineer (rather than, for example, describing the details of the physics of the basic device operation itself). Equations are developed that describe the effects of defocus and hold-off time on the relation between the number of photons detected by the array and the output of photo-electron counts. We show how to incorporate these equations into a link budget. The resulting predictions are validated by comparison against simulation results. Finally, we compare the performance of linear mode APD based receivers and Geiger mode APD array based receivers. Results show the Geiger mode receivers yield better performance, in terms of probability of bit error, at lower signal levels, except on links where there is an exceptionally large amount of background noise. Under those conditions, not surprisingly, the hold-off time degrades performance.

  9. Determination of benzimidazole anthelmintics in animal-derived biological matrices.

    PubMed

    Neri, Bruno; Bidolli, Gentilina; Felli, Marialinda; Cozzani, Roberto

    2002-04-01

    This paper describes an easy multiresidue procedure for the determination of 8 benzimidazole anthelmintics (Albendazole, Albendazole sulphone, Albendazole sulphoxide, Ox-bendazole, Ossibendazole, p-OH-Fenbendazole, Fenbendazole, Flubendazole) in foodstuffs of animal origin for human consumption. According to the proposed procedure, 10 g of homogenised sample were extracted with acetonitrile in ultrasonic bath, the organic layer was evaporated to dryness and the residue dissolved in HCl 0.005 M. After an initial washing with hexane to remove fats, the aqueous layer was purified on SPE C2 column and the analytes were eluted with methanol, evaporated to dryness and reconstituted with phosphate buffer/acetonitrile (50/50). The solution obtained was analysed by HPLC with diode array detector (DAD); this detector provides useful information about the peaks present in routine samples, because it gains not only retention times of analytes, as well as their UV-spectra. Benzthiazuron was used as internal standard and the method was validated in the range 10-100 ppb, as requested by the imposed limits. The mean recoveries in spiked samples ranged between 70% and 95%, for 10 and 100 ppb respectively. The developed method resulted sensitive, simple and fast. It is particularly suitable for laboratories that execute screening analysis on a great number of samples, observing the EC regulations that establish the benzimidazole Maximum Residue Limits (MRLs) in food.

  10. Comprehensive two-dimensional HPLC to study the interaction of multiple components in Rheum palmatum L. with HSA by coupling a silica-bonded HSA column to a silica monolithic ODS column.

    PubMed

    Hu, Lianghai; Li, Xin; Feng, Shun; Kong, Liang; Su, Xingye; Chen, Xueguo; Qin, Feng; Ye, Mingliang; Zou, Hanfa

    2006-04-01

    A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.

  11. Operation and performance of new NIR detectors from SELEX

    NASA Astrophysics Data System (ADS)

    Atkinson, D.; Bezawada, N.; Hipwood, L. G.; Shorrocks, N.; Milne, H.

    2012-07-01

    The European Space Agency (ESA) has funded SELEX Galileo, Southampton, UK to develop large format near infrared (NIR) detectors for its future space and ground based programmes. The UKATC has worked in collaboration with SELEX Galileo to test and characterise the new detectors produced during phase-1 of the development. In order to demonstrate the detector material performance, the HgCdTe (MCT) detector diodes (grown on GaAs substrate through MOVPE process in small 320×256, 24μm pixel format) are hybridised to the existing SELEX Galileo SWALLOW CMOS readout chip. The substrate removed and MCT thinned detector arrays were then tested and evaluated at the UKATC following screening tests at SELEX. This paper briefly describes the test setup, the operational aspects of the readout multiplexer and presents the performance parameters of the detector arrays including: conversion gain, detector dark current, read noise, linearity, quantum efficiency and persistence for various detector temperatures between 80K and 140K.

  12. Metal organic frameworks (MOFs) for magnetic solid-phase extraction of pyrazole/pyrrole pesticides in environmental water samples followed by HPLC-DAD determination.

    PubMed

    Ma, Jiping; Yao, Zhidan; Hou, Liwei; Lu, Wenhui; Yang, Qipeng; Li, Jinhua; Chen, Lingxin

    2016-12-01

    Magnetic metal-organic frameworks (MOFs, [MIL-101]) were prepared and used as magnetic solid-phase extraction (MSPE) adsorbents for preconcentration of four kinds of pyrazole/pyrrole pesticides (flusilazole, fipronil, chlorfenapyr, and fenpyroximate) in environmental water samples, followed by high-performance liquid chromatography-diode-array detector (HPLC-DAD) determination. Several variables affecting MSPE efficiency were systematically investigated, including amount of MIL-101, extraction time, sample pH, salt concentration, type of desorption solvent and desorption number of times. Under optimized conditions, excellent linearity was achieved in the range of 5.0-200.0μg/L for flusilazole and fipronil, and 2.0-200.0μg/L for chlorfenapyr and fenpyroximate, with correlation coefficients r>0.9911. Limits of detection and quantification were 0.3-1.5μg/L and 1.0-5.0μg/L, respectively. The intra-day and inter-day precision (relative standard deviation, n=6, %) at three spiked levels were 1.1-5.4% and 3.9-7.8% in terms of peak area, respectively. The method recoveries at three fortified concentration levels ranged from 81.8% to 107.5% for reservoir water samples, 81.0-99.5% for river water samples, and 80.2-106.5% for seawater samples. The developed MOFs based MSPE coupled with HPLC method proved to be a convenient, rapid and eco-friendly alternative to the sensitive determination of pyrazole/pyrrole pesticides with high repeatability and excellent practical applicability. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. An improved independent component analysis model for 3D chromatogram separation and its solution by multi-areas genetic algorithm

    PubMed Central

    2014-01-01

    Background The 3D chromatogram generated by High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD) has been researched widely in the field of herbal medicine, grape wine, agriculture, petroleum and so on. Currently, most of the methods used for separating a 3D chromatogram need to know the compounds' number in advance, which could be impossible especially when the compounds are complex or white noise exist. New method which extracts compounds from 3D chromatogram directly is needed. Methods In this paper, a new separation model named parallel Independent Component Analysis constrained by Reference Curve (pICARC) was proposed to transform the separation problem to a multi-parameter optimization issue. It was not necessary to know the number of compounds in the optimization. In order to find all the solutions, an algorithm named multi-areas Genetic Algorithm (mGA) was proposed, where multiple areas of candidate solutions were constructed according to the fitness and distances among the chromosomes. Results Simulations and experiments on a real life HPLC-DAD data set were used to demonstrate our method and its effectiveness. Through simulations, it can be seen that our method can separate 3D chromatogram to chromatogram peaks and spectra successfully even when they severely overlapped. It is also shown by the experiments that our method is effective to solve real HPLC-DAD data set. Conclusions Our method can separate 3D chromatogram successfully without knowing the compounds' number in advance, which is fast and effective. PMID:25474487

  14. Rapid Identification and Quantification of Natural Antioxidants in the Seeds of Rhubarb from Different Habitats in China Using Accelerated Solvent Extraction and HPLC-DAD-ESI-MSn-DPPH Assay.

    PubMed

    Tan, Liang; Geng, Dan-dan; Hu, Feng-zu; Dong, Qi

    2016-01-01

    In this study, the 10 accessions of rhubarb seeds from different habitats in China were investigated. Lipids were removed using petroleum ether, and the effective components were then separated using accelerated solvent extraction with 80% aqueous methanol. An off-line 2,2-diphenyl-1-picrylhydrazyl (DPPH) free-radical scavenging method was used as the marker to evaluate the total antioxidant capability of extracts. On-line high-performance liquid chromatography-diode-array detectors-electrospray ionization-tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) and HPLC-DAD-DPPH assays were developed for rapid identification and quantification of individual free-radical scavengers in extracts of rhubarb seeds. Ten free-radical scavengers from methanolic extracts of the rhubarb seeds were screened, five of which were identified and quantitatively analyzed: epicatechin, myricetin, hyperoside, quercitrin and quercetin. All were identified in rhubarb seeds for the first time and can be regarded as the major potent antioxidants in rhubarb seeds due to representing most of the total free-radical scavenging activity. Preliminary analysis of structures was performed for another five antioxidants. Based on our validation results, the developed method can be used for rapid separation, convenient identification and quantification of the multiple antioxidative constituents in rhubarb seeds, featuring good quantification parameters, accuracy and precision. The results are important to clarify the material basis and therapeutic mechanism of rhubarb seeds. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Phenolic compounds participating in mulberry juice sediment formation during storage.

    PubMed

    Zou, Bo; Xu, Yu-Juan; Wu, Ji-Jun; Yu, Yuan-Shan; Xiao, Geng-Sheng

    The stability of clarified juice is of great importance in the beverage industry and to consumers. Phenolic compounds are considered to be one of the main factors responsible for sediment formation. The aim of this study is to investigate the changes in the phenolic content in clarified mulberry juice during storage. Hence, separation, identification, quantification, and analysis of the changes in the contents of phenolic compounds, both free and bound forms, in the supernatant and sediments of mulberry juice, were carried out using high performance liquid chromatographic system, equipped with a photo-diode array detector (HPLC-PDA) and HPLC coupled with quadrupole-time of flight mass spectrometric (HPLC-QTOF-MS/MS) techniques. There was an increase in the amount of sediment formed over the period of study. Total phenolic content of supernatant, as well as free phenolic content in the extracts of the precipitate decreased, whereas the bound phenolic content in the sediment increased. Quantitative estimation of individual phenolic compounds indicated high degradation of free anthocyanins in the supernatant and sediment from 938.60 to 2.30 mg/L and 235.60 to 1.74 mg/g, respectively. A decrease in flavonoids in the supernatant was also observed, whereas the contents of bound forms of gallic acid, protocatechuic acid, caffeic acid, and rutin in the sediment increased. Anthocyanins were the most abundant form of phenolics in the sediment, and accounted for 67.2% of total phenolics after 8 weeks of storage. These results revealed that phenolic compounds, particularly anthocyanins, were involved in the formation of sediments in mulberry juice during storage.

  16. A simple HPLC-DAD method for simultaneous detection of two organophosphates, profenofos and fenthion, and validation by soil microcosm experiment.

    PubMed

    Mahajan, Rishi; Chatterjee, Subhankar

    2018-05-05

    Indiscriminate use of two broad spectrum pesticides, profenofos and fenthion, in agricultural system, often results in their accumulation in a non-target niche and leaching into water bodies. The present study, therefore, aims at developing a simple and rapid HPLC method that allows simultaneous extraction and detection of these two pesticides, especially in run-off water. Extraction of the two pesticides from spiked water samples using dichloromethane resulted in recovery ranging between 80 and 90%. An HPLC run of 20 min under optimized chromatographic parameters (mobile phase: methanol (75%) and water (25%); flow rate of 0.8 ml min -1 ; diode array detector at wavelength 210 nm) resulted in a significant difference in retention times of two pesticides (4.593 min) which allows a window of opportunity to study any possible intermediates/transformants of the parent compounds while evaluating run-off waters from agricultural fields. The HPLC method developed allowed simultaneous detection of profenofos and fenthion with a single injection into the HPLC system with 0.0328 mg l -1 (32.83 ng ml -1 ) being the limit of detection (LOD) and 0.0995 mg l -1 (99.5 ng ml -1 ) as the limit of quantification (LOQ) for fenthion; for profenofos, LOD and LOQ were 0.104 mg l -1 (104.50 ng ml -1 ) and 0.316 mg l -1 (316.65 ng ml -1 ), respectively. The findings were further validated using the soil microcosm experiment that allowed simultaneous detection and quantification of profenofos and fenthion. The findings indicate towards the practical significance of the methodology developed as the soil microcosm experiment closely mimics the agricultural run-off water under natural environmental conditions.

  17. FPGA-based gating and logic for multichannel single photon counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pooser, Raphael C; Earl, Dennis Duncan; Evans, Philip G

    2012-01-01

    We present results characterizing multichannel InGaAs single photon detectors utilizing gated passive quenching circuits (GPQC), self-differencing techniques, and field programmable gate array (FPGA)-based logic for both diode gating and coincidence counting. Utilizing FPGAs for the diode gating frontend and the logic counting backend has the advantage of low cost compared to custom built logic circuits and current off-the-shelf detector technology. Further, FPGA logic counters have been shown to work well in quantum key distribution (QKD) test beds. Our setup combines multiple independent detector channels in a reconfigurable manner via an FPGA backend and post processing in order to perform coincidencemore » measurements between any two or more detector channels simultaneously. Using this method, states from a multi-photon polarization entangled source are detected and characterized via coincidence counting on the FPGA. Photons detection events are also processed by the quantum information toolkit for application testing (QITKAT)« less

  18. Rapid Identification of unstable acyl glucoside flavonoids of Oxytropis racemosa Turcz by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry.

    PubMed

    Song, Shuang; Zheng, Xiu-Ping; Liu, Wei-Dong; Du, Rui-Fang; Feng, Zi-Ming; Zhang, Pei-Cheng; Bi, Li-Fu

    2013-02-01

    Oxytropis racemosa Turcz is an important minority medicine that is used mainly to improve children's indigestion, especially in inner Mongolia and Tibet. Previous studies indicated that the characteristic constituents of this plant are acylated flavonoids. Rapidly identify the characteristic chemical constituents of O. racemosa by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry (HPLC-DAD-ESI/MS(n) ) and suggest a useful method to control the quality of this medicinal plant. In the HPLC fingerprint, 32 flavonoids were tentatively identified by a detailed analysis of their mass spectra, UV spectra and retention times. Furthermore, 13 flavonoids were confirmed by comparison with previously isolated compounds obtained from O. racemosa. In total, 32 flavonoids, including 13 flavonoids with 3-hydroxy-3-methylglutaric acid (HMG) moieties and four flavonoids with 3-malonyl moieties, were identified in the extract of O. racemosa. Among the compounds identified, 10 were characterised as new compounds for their particular acylated sugar moieties. The method described is effective for obtaining a comprehensive phytochemical profile of plants containing unstable acylated flavonoids. The method is also useful for constructing the chromatographic fingerprint of the minority medicine -O. racemosa Turcz for quality control. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Determination of phenol compounds in surface water matrices by bar adsorptive microextraction-high performance liquid chromatography-diode array detection.

    PubMed

    Neng, Nuno R; Nogueira, José M F

    2014-07-03

    Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4-n-nonylphenol) in surface water matrices. By using a polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phase, high selectivity and efficiency is achieved even against polydimethylsiloxane through stir bar sorptive extraction. Assays performed by BAµE(PS-DVB)-LD/HPLC-DAD on 25 mL water samples spiked at the 10.0 µg/L levels yielded recoveries over 88.0%±5.7% for all five analytes, under optimized experimental conditions. The analytical performance showed good precision (RSD<15%), detection limits of 0.25 µg/L and linear dynamic ranges (1.0-25.0 μg/L) with determination coefficient higher than 0.9904. By using the standard addition method, the application of the present method to surface water matrices allowed very good performances at the trace level. The proposed methodology proved to be a suitable alternative to monitor phenol compounds in surface water matrices, showing to be easy to implement, reliable, sensitive and requiring a low sample volume.

  20. Quantitative analysis of the eight major compounds in the Samsoeum using a high-performance liquid chromatography coupled with diode array detection and electrospray ionization mass spectrometer

    PubMed Central

    Weon, Jin Bae; Yang, Hye Jin; Lee, Bohyoung; Ma, Jin Yeul; Ma, Choong Je

    2015-01-01

    Background: Samsoeum was traditionally used for treatment of a respiratory disease. Objective: The simultaneous determination of eight major compounds, ginsenoside Rg3, caffeic acid, puerarin, costunolide, hesperidin, naringin, glycyrrhizin, and 6-gingerol in the Samsoeum using a high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) and an electrospray ionization mass spectrometer was developed for an accurate and reliable quality assessment. Materials and Methods: Eight compounds were qualitative identified based on their mass spectra and by comparing with standard compounds and quantitative analyzed by HPLC-DAD. Separation of eight compounds was carried out on a LUNA C18 column (S-5 μm, 4.6 mm i.d. ×250 mm) with gradient elution composed of acetonitrile and 0.1% trifluoroacetic acid. Results: The data showed good linearity (R2 > 0.9996). The limits of detection and the limits of quantification were <0.53 μg and 1.62 μg, respectively. Inter- and Intra-day precisions (expressed as relative standard deviation values) were within 1.94% and 1.91%, respectively. The recovery of the method was in the range of 94.24–107.90%. Conclusion: The established method is effective and could be applied to quality control of Samsoeum. PMID:25829771

  1. Imaging photovoltaic infrared CdHgTe detectors

    NASA Astrophysics Data System (ADS)

    Haakenaasen, R.; Steen, H.; Selvig, E.; Lorentzen, T.; van Rheenen, A. D.; Trosdahl-Iversen, L.; Hall, D.; Gordon, N.; Skauli, T.; Vaskinn, A. H.

    2006-09-01

    CdxHg1-xTe layers with bandgap in the mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) regions were grown by molecular beam epitaxy, and one-dimensional (1D) and two-dimensional (2D) arrays of planar photodiodes were fabricated by ion milling of vacancy-doped layers. The grown layers have varying densities of needle-shaped structures on the surface. The needles are not associated with twins or dislocations in the layers, but could instead be due to (111) facets being reinforced by a preferential Te diffusion direction over steps on the surface. The needles do not seem to affect diode quality. 64 element 1D arrays of 26×26 μm2 or 26×56 μm2 diodes were processed, and zero-bias resistance-times-area values (R0A) at 77 K of 4×106 Ω cm2 at cutoff wavelength λCO=4.5 μm were measured, as well as high quantum efficiencies. To avoid creating a leakage current during ball-bonding to the 1D array diodes, a ZnS layer was deposited on top of the CdTe passivation layer, as well as extra electroplated Au on the bonding pads. The median measured noise equivalent temperature difference (NETD) on a LWIR array was 14 mK for the 42 operable diodes. 2D arrays showed reasonably good uniformity of R0A and zero-bias current (I0) values. The first 64×64 element 2D array of 16×16 μm2 MWIR diodes has been hybridized to read-out electronics and gave median NETD of 60 mK. Images from both a 1D and a 2D array are shown.

  2. Sequential cloud-point extraction for toxicological screening analysis of medicaments in human plasma by high pressure liquid chromatography with diode array detector.

    PubMed

    Madej, Katarzyna; Persona, Karolina; Wandas, Monika; Gomółka, Ewa

    2013-10-18

    A complex extraction system with the use of cloud-point extraction technique (CPE) was developed for sequential isolation of basic and acidic/neutral medicaments from human plasma/serum, screened by HPLC/DAD method. Eight model drugs (paracetamol, promazine, chlorpromazine, amitriptyline, salicyclic acid, opipramol, alprazolam and carbamazepine) were chosen for the study of optimal CPE conditions. The CPE technique consists in partition of an aqueous sample with addition of a surfactant into two phases: micelle-rich phase with the isolated compounds and water phase containing a surfactant below the critical micellar concentration, mainly under influence of temperature change. The proposed extraction system consists of two chief steps: isolation of basic compounds (from pH 12) and then isolation of acidic/neutral compounds (from pH 6) using surfactant Triton X-114 as the extraction medium. Extraction recovery varied from 25.2 to 107.9% with intra-day and inter-day precision (RSD %) ranged 0.88-1087 and 5.32-17.96, respectively. The limits of detection for the studied medicaments at λ 254nm corresponded to therapeutic or low toxic plasma concentration levels. Usefulness of the proposed CPE-HPLC/DAD method for toxicological drug screening was tested via its application to analysis of two serum samples taken from patients suspected of drug overdosing. Published by Elsevier B.V.

  3. Anthocyanin production in callus cultures of Cleome rosea: modulation by culture conditions and characterization of pigments by means of HPLC-DAD/ESIMS.

    PubMed

    Simões, Claudia; Brasil Bizarri, Carlos Henrique; da Silva Cordeiro, Lívia; Carvalho de Castro, Tatiana; Machado Coutada, Leonardo César; Ribeiro da Silva, Antônio Jorge; Albarello, Norma; Mansur, Elisabeth

    2009-10-01

    Leaf and stem explants of Cleome rosea formed calluses when cultured on MS medium supplemented with different concentrations of 2,4-dichlorophenoxyacetic acid (2,4-D) or 4-amino-3,5,6-trichloropicolinic acid (PIC). The highest biomass accumulation was obtained in the callus cultures initiated from stem explants on medium supplemented with 0.90 microM 2,4-D. Reddish-pink regions were observed on callus surface after 6-7 months in culture and these pigments were identified as anthocyanins. Anthocyanins production was enhanced by reducing temperature and increasing light irradiation. Pigmented calluses transferred to MS1/2 with a 1:4 ratio NH(4)(+)/NO(3)(-), 70 g L(-1) sucrose and supplementation with 0.90 microM 2,4-D maintained a high biomass accumulation and showed an increase of 150% on anthocyanin production as compared with the initial culture conditions. Qualitative analysis of calluses was performed by high performance liquid chromatography coupled to diode array detector and electrospray ionization mass spectrometry (HPLC-DAD/ESIMS). Eleven anthocyanins were characterized and the majority of them were identified as acylated cyanidins, although two peonidins were also detected. The major peak was composed by two anthocyanins, whose proposed identity were cyanidin 3-(p-coumaroyl) diglucoside-5-glucoside and cyanidin 3-(feruloyl) diglucoside-5-glucoside.

  4. HPLC determination of cefprozil in tablets using monolithic and C18 silica columns.

    PubMed

    Can, Nafiz O

    2011-08-01

    Cefprozil (CPZ) is a second-generation semi-synthetic cephalosporin antibiotic that commonly exists as the mixture of Z and E diastereoisomers, at the ratio of approximately 9:1. A novel reversed-phase HPLC method for the determination of CPZ in tablets was described. The separation of CPZ diastereoisomers and caffeine (internal standard) was carried out by applying the same analytical and instrumental conditions on two stationary phases, which have different surface chemistries. The columns used in the study were monolithic silica Merck Chromolith Performance RP-18e and conventional C18 silica Phenomenex Synergi Hydro RP columns. In total, 10 μL aliquots of samples were injected into the system and eluted using water-acetonitrile (90:10, v/v) solution, which was pumped through the column at a flow rate of 1.0 mL/min. The analyte peaks were detected at 200 nm using diode array detector with high specificity. CPZ diastereoisomers and caffeine were measured within 13 min using the C18 column, whereas <5 min was required for the monolithic one. Validation studies were performed according to official recommendations. Value of a monolithic column for the assay of diastereoisomers in pharmaceutical tablets was evaluated for the first time and found as a powerful alternative to highly efficient C18 columns. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The establishment of tocopherol reference intervals for Hungarian adult population using a validated HPLC method.

    PubMed

    Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes

    2017-09-01

    Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Capillary-HPLC with tandem mass spectrometry in analysis of alkaloid dyestuffs - a new approach.

    PubMed

    Dąbrowski, Damian; Lech, Katarzyna; Jarosz, Maciej

    2018-05-01

    Development of the identification method of alkaloid compounds in Amur cork tree as well as not examined so far Oregon grape and European Barberry shrubs are presented. The novel approach to separation of alkaloids was applied and the capillary-high-performance liquid chromatography (capillary-HPLC) system was used, which has never previously been reported for alkaloid-based dyestuffs analysis. Its optimization was conducted with three different stationary phases (unmodified octadecylsilane-bonded silica, octadecylsilane modified with polar groups and silica-bonded pentaflourophenyls) as well as with different solvent buffers. Detection of the isolated compounds was carried out using diode-array detector (DAD) and tandem mass spectrometer with electrospray ionization (ESI MS/MS). The working parameters of ESI were optimized, whereas the multiple reactions monitoring (MRM) parameters of MS/MS detection were chosen based on the product ion spectra of the quasi-molecular ions. Calibration curve of berberine has been estimated (y = 1712091x + 4785.03 with the correlation coefficient 0.9999). Limit of detection and limit of quantification were calculated to be 3.2 and 9.7 ng/mL, respectively. Numerous alkaloids (i.e., berberine, jatrorrhizine and magnoflorine, as well as phellodendrine, menisperine and berbamine) were identified in the extracts from alkaloid plants and silk and wool fibers dyed with these dyestuffs, among them their markers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Efficient scalable solid-state neutron detector.

    PubMed

    Moses, Daniel

    2015-06-01

    We report on scalable solid-state neutron detector system that is specifically designed to yield high thermal neutron detection sensitivity. The basic detector unit in this system is made of a (6)Li foil coupled to two crystalline silicon diodes. The theoretical intrinsic efficiency of a detector-unit is 23.8% and that of detector element comprising a stack of five detector-units is 60%. Based on the measured performance of this detector-unit, the performance of a detector system comprising a planar array of detector elements, scaled to encompass effective area of 0.43 m(2), is estimated to yield the minimum absolute efficiency required of radiological portal monitors used in homeland security.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, P; Cammin, J; Solberg, T

    Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX whilemore » the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.« less

  9. Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection.

    PubMed

    Sun, Yan-Mei; Wu, Hai-Long; Wang, Jian-Yao; Liu, Zhi; Zhai, Min; Yu, Ru-Qin

    2014-07-01

    A fast analytical strategy of second-order calibration method based on the alternating trilinear decomposition algorithm (ATLD)-assisted high performance liquid chromatography coupled with a diode array detector (HPLC-DAD) was established for the simultaneous determination of eight flavonoids (rutin, quercetin, luteolin, kaempferol, isorhamnetin, apigenin, galangin and chrysin) in propolis capsules samples. The chromatographic separation was implemented on a Wondasil™ C18 column (250mm×4.6mm, 5μm) within 13min with a binary mobile phase composed of water with 1% formic acid and methanol at a flow rate of 1.0mLmin(-1) after flavonoids were only extracted with methanol by ultrasound extraction for 15min. The baseline problem was overcome by considering background drift as additional compositions or factors as well as the target analytes, and ATLD was employed to handle the overlapping peaks from analytes of interest or from analytes and co-eluting matrix compounds. The linearity was good with the correlation coefficients no less than 0.9947; the limit of detections (LODs) within the range of 3.39-33.05ngmL(-1) were low enough; the accuracy was confirmed by the recoveries ranged from 91.9% to 110.2% and the root-mean-square-error of predictions (RMSEPs) less than 1.1μg/mL. The results indicated that the chromatographic method with the aid of ATLD is efficient, sensitive and cost-effective and can realize the resolution and accurate quantification of flavonoids even in the presence of interferences, thus providing an alternative method for accurate quantification of analytes especially when the complete separation is not easily accomplished. The method was successfully applied to propolis capsules samples and the satisfactory results were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Application of high-performance liquid chromatography with ultraviolet diode array detection and refractive index detection to the determination of class composition and to the analysis of gasoline.

    PubMed

    Kamiński, Marian; Kartanowicz, Rafał; Przyjazny, Andrzej

    2004-03-12

    A method of effective application of normal-phase high-performance liquid chromatography (NP-HPLC) with ultraviolet diode array detection (DAD) and refractive index detection (RID) for the determination of class composition of gasoline and its components, i.e. for the determination of content of alkenes, aromatic and saturated hydrocarbons in gasoline meeting modern quality standards, has been developed. An aminopropyl-bonded silica stationary phase was used along with n-hexane or n-heptane as the mobile phase. A DAD signal integrated over the 207-240 nm range was used to determine alkenes. This eliminates the necessity of separating alkenes from saturates, because the latter do not absorb UV radiation above 200 nm. The content of aromatic hydrocarbons is determined by means of a refractive index detector. Calibration was based on hydrocarbon type composition determined by the fluorescent indicator adsorption method, ASTM D1319. The results obtained by the developed method were found to be consistent with those obtained by fluorescent indicator adsorption or by a multidimensional GC method (PIONA) (ASTM D5443). The method can be applied to gasoline meeting recent quality standards, irrespective of refining technology used in the production of gasoline components, including gasoline with various contents of oxygenates. The developed method cannot be used to determine the hydrocarbon type composition of gasoline that contains as a component the so-called pyrocondensate, i.e. the fraction with a boiling point up to 220 degrees C, obtained through thermal pyrolysis of distillation residues of crude oil or coal and, consequently, does not meet the quality standards. The paper includes the procedure for identification of this type of gasoline.

  11. Experience from operating germanium detectors in GERDA

    NASA Astrophysics Data System (ADS)

    Palioselitis, Dimitrios; GERDA Collaboration

    2015-05-01

    Phase I of the Germanium Detector Array (GERDA) experiment, searching for the neutrinoless double beta (0νββ) decay of 76Ge, was completed in September 2013. The most competitive half-life lower limit for the 0νββ decay of 76Ge was set (T-0ν1/2 > 2.1 · 1025 yr at 90% C.L.). GERDA operates bare Ge diodes immersed in liquid argon. During Phase I, mainly refurbished semi-coaxial high purity Ge detectors from previous experiments were used. The experience gained with handling and operating bare Ge diodes in liquid argon, as well as the stability and performance of the detectors during GERDA Phase I are presented. Thirty additional new enriched BEGe-type detectors were produced and will be used in Phase II. A subgroup of these detectors has already been used successfully in GERDA Phase I. The present paper gives an overview of the production chain of the new germanium detectors, the steps taken to minimise the exposure to cosmic radiation during manufacturing, and the first results of characterisation measurements in vacuum cryostats.

  12. Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study

    PubMed Central

    Brondi, Ariadne M.; Garcia, Jerusa S.

    2017-01-01

    A study was carried out to investigate compatibility of amlodipine besylate and olmesartan medoxomil with a variety of pharmaceutical excipients. Both drugs are antihypertensive agents that can be administered alone, in monotherapy, or in pharmaceutical association. The studies were performed using binary and ternary mixtures, and samples were stored for 3 and 6 months at 40°C under 75% relative humidity and dry conditions. For this study, a method based on high-performance liquid chromatography (HPLC) was developed and validated for the simultaneous determination of amlodipine besylate and olmesartan medoxomil in samples from pharmaceutical preformulation studies using diode array detector (DAD) and charged aerosol detector (CAD). The runtime per sample was 10 min with retention time of 7.926 min and 4.408 min for amlodipine and olmesartan, respectively. The validation was performed according to ICH guidelines. The calibration curve presents linear dynamic range from 12 to 250 μg mL−1 for amlodipine and from 25 to 500 μg mL−1 for olmesartan with coefficient of determination (R2 ≥ 0.9908) while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.0%. The excipients such as corn starch, croscarmellose sodium, magnesium stearate, polyvinyl alcohol, talc, polyvinylpyrrolidone, lactose monohydrate, and polyethylene glycol showed potential incompatibilities after accelerated stability testing. PMID:29391967

  13. Phytoecdysteroids from Atriplex nummularia.

    PubMed

    Keckeis, K; Sarker, S D; Dinan, L N

    2000-08-01

    A bioassay for ecdysteroid agonists/antagonists and ecdysteroid-specific radioimmunoassays, together with a photo-diode-array detector-monitored high-performance liquid chromatography, have been used to analyse a methanol extract of the seeds of Atriplex nummularia. This yielded two phytoecdysteroids, 20-hydroxyecdysone (1) and polypodine B (2).

  14. GeSn Based Near and Mid Infrared Heterostructure Detectors

    DTIC Science & Technology

    2018-02-07

    prestigious journals. 15.  SUBJECT TERMS Plasmonic Enhancement, Metal Nanostructures, CMOS, Photodetectors, Germanium- Tin Diode, IR Focal Plane Array...can be achieved by using current developed chemical vapor deposition technique. Optical properties of germanium tin (Ge1-xSnx) alloys have been

  15. Macroscopic Violation of Three Cauchy-Schwarz Inequalities Using Correlated Light Beams From an Infra-Red Emitting Semiconductor Diode Array

    NASA Technical Reports Server (NTRS)

    Edwards, P. J.; Huang, X.; Li, Y. Q. (Editor); Wang, Y. Z. (Editor)

    1996-01-01

    We briefly review quantum mechanical and semi-classical descriptions of experiments which demonstrate the macroscopic violation of the three Cauchy-Schwarz inequalities: g(sup 2)(sub 11)(0) greater than or equal to 1; g(sup 2)(sub 11)(0) greater than or equal to g(sup 2)(sub 11)(t), (t approaches infinity); (the absolute value of g(sup 2)(sub 11)(0))(exp 2) less than or equal to g(sup 2)(sub 11)(0) g(sup 2)(sub 11)(0). Our measurements demonstrate the violation, at macroscopic intensities, of each of these inequalities. We show that their violation, although weak, can be demonstrated through photodetector current covariance measurements on correlated sub-Poissonian Poissonian, and super Poissonian light beams. Such beams are readily generated by a tandem array of infrared-emitting semiconductor junction diodes. Our measurements utilize an electrically coupled array of one or more infrared-emitting diodes, optically coupled to a detector array. The emitting array is operated in such a way as to generate highly correlated beams of variable photon Fano Factor. Because the measurements are made on time scales long compared with the first order coherence time and with detector areas large compared with the corresponding coherence areas, first order interference effects are negligible. The first and second inequalities are violated, as expected, when a sub-Poissonian light beam is split and the intensity fluctuations of the two split beams are measured by two photodetectors and subsequently cross-correlated. The third inequality is violated by bunched (as well as anti-bunched) beams of equal intensity provided the measured cross correlation coefficient exceeds (F - 1)/F, where F is the measured Fano Factor of each beam. We also investigate the violation for the case of unequal beams.

  16. Novel Photon-Counting Detectors for Free-Space Communication

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.; Yang, Guan; Sun, Xiaoli; Lu, Wei; Merritt, Scott; Beck, Jeff

    2016-01-01

    We present performance data for novel photon counting detectors for free space optical communication. NASA GSFC is testing the performance of three novel photon counting detectors 1) a 2x8 mercury cadmium telluride avalanche array made by DRS Inc. 2) a commercial 2880 silicon avalanche photodiode array and 3) a prototype resonant cavity silicon avalanche photodiode array. We will present and compare dark count, photon detection efficiency, wavelength response and communication performance data for these detectors. We discuss system wavelength trades and architectures for optimizing overall communication link sensitivity, data rate and cost performance. The HgCdTe APD array has photon detection efficiencies of greater than 50 were routinely demonstrated across 5 arrays, with one array reaching a maximum PDE of 70. High resolution pixel-surface spot scans were performed and the junction diameters of the diodes were measured. The junction diameter was decreased from 31 m to 25 m resulting in a 2x increase in e-APD gain from 470 on the 2010 array to 1100 on the array delivered to NASA GSFC. Mean single photon SNRs of over 12 were demonstrated at excess noise factors of 1.2-1.3.The commercial silicon APD array has a fast output with rise times of 300ps and pulse widths of 600ps. Received and filtered signals from the entire array are multiplexed onto this single fast output. The prototype resonant cavity silicon APD array is being developed for use at 1 micron wavelength.

  17. Simultaneous determination of eight major steroids from Polyporus umbellatus by high-performance liquid chromatography coupled with mass spectrometry detections.

    PubMed

    Zhao, Ying-yong; Cheng, Xian-long; Zhang, Yongmin; Zhao, Ye; Lin, Rui-chao; Sun, Wen-ji

    2010-02-01

    Polyporus umbellatus is a widely used diuretic herbal medicine. In this study, a high-performance liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometric detection (HPLC-APCI-MS) method was developed for qualitative and quantitative analysis of steroids, as well as for the quality control of Polyporus umbellatus. The selectivity, reproducibility and sensitivity were compared with HPLC with photodiode array detection and evaporative light scattering detection (ELSD). Selective ion monitoring in positive mode was used for qualitative and quantitative analysis of eight major components and beta-ecdysterone was used as the internal standard. Limits of detection and quantification fell in the ranges 7-21 and 18-63 ng/mL for the eight analytes with an injection of 10 microL samples, and all calibration curves showed good linear regression (r(2) > 0.9919) within the test range. The quantitative results demonstrated that samples from different localities showed different qualities. Advantages, in comparison with conventional HPLC-diode array detection and HPLC-ELSD, are that reliable identification of target compounds could be achieved by accurate mass measurements along with characteristic retention time, and the great enhancement in selectivity and sensitivity allows identification and quantification of low levels of constituents in complex Polyporus umbellatus matrixes. (c) 2009 John Wiley & Sons, Ltd.

  18. Quantification of astaxanthin in shrimp waste hydrolysate by HPLC.

    PubMed

    López-Cervantes, J; Sánchez-Machado, D I; Gutiérrez-Coronado, M A; Ríos-Vázquez, N J

    2006-10-01

    In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.

  19. An efficient separation and method development for the quantifying of two basic impurities of Nicergoline by reversed-phase high performance liquid chromatography using ion-pairing counter ions.

    PubMed

    Yalçin, Güler; Yüktaş, Nüray

    2006-10-11

    A quantification method was developed for the two basic impurities, one of which is also a metabolite, of Nicergoline (NIC), by using reversed-phase high performance liquid chromatography (RP-HPLC) and diode array detector (DAD). One of these compounds,10-methoxy-6-methylergoline-8beta-methanol-5-bromo-3-pyridinecarboxylate (1-DN) is the metabolite as well as the impurity whereas, the other 10-methoxy-1,6-dimethylergoline-8beta-methanol-5-chloro-3-pyridinecarboxylate (5-CN) is only an impurity. The chromatographic column was Phenomenex, Luna, 5 microm, C18 (2), 250 mm x 4.6 mm. Mobile phase was 0.1 M ammonium acetate (NH4Ac) solution containing 4 mM 1-octanesulfonicacid sodium salt (OSASS) and 6 mM tetrabutylammonium hydrogen sulphate (TBAHS) (pH: 5.9)/acetonitrile (ACN) (62:38) for 1-DN and (64:36) for 5-CN. Flow rate was 1.0 mL min-1. The diode array detector was operated at 285 nm, band width: 4 nm. Linearity was obtained in the concentration range of 0.032 x 10-5 to 3.828 x 10-5 M, y = 116.88x + 0.2773 (r2 = 0.99989); the limit of detection (LOD) and limit of quantification (LOQ) were determined as 0.012 x 10-5 and 0.041 x 10-5 M for 1-DN, respectively. Linearity was obtained in the concentration range of 0.034 x 10-5 to 4.092 x 10-5 M, y = 104.24x + 0.7486 (r2 = 0.99996); (LOD) and (LOQ) were determined as 0.014 x 10-5 and 0.046 x 10-5 M for 5-CN, respectively. The recovery was 100.65% for 1-DN and 100.32% for 5-CN. The amount of 1-DN in 30 mg NIC was found as 209.65 microg (0.70%) and the amount of 5-CN in 30 mg NIC was found as 27.62 microg (0.09%).

  20. Analysis of the influence of processing of stir-baking with glycyrrhizae on the main components of Euodiae Fructus by high-performance liquid chromatography with diode array detector.

    PubMed

    Hu, Jue; Wu, Xin; Cao, Gang; Chen, Xiaocheng

    2014-01-01

    Euodiae Fructus is one of the most commonly used Chinese herbs in China. Specifically, the crude Euodiae Fructus and its processed products of Gancao Zhi Pin are used clinically for the treatment of different diseases. In order to improve the quality control standard and evaluate the crude and processed Euodiae Fructus, in this study, a simple and sensitive high-performance liquid chromatography-diode array detector method was developed for the simultaneous determination of five major compounds in Euodiae Fructus. The results indicated that the five components had significant linear relation (r(2) ≥ 0.9997) between the peak area and the injected concentration. The average recoveries of the five components were in the range from 97.38% to 102.56%. Overall intra- and inter-day variations were less than 1.36%. The developed method can be applied to the intrinsic quality control of crude and processed Euodiae Fructus.

  1. Polycyclic aromatic hydrocarbons in the bakery chain.

    PubMed

    Ciecierska, M; Obiedziński, M W

    2013-11-01

    The level of polycyclic aromatic hydrocarbons occurrence and the possibility of their formation in the bakery chain, its raw materials and final products, were examined. Experimental bread baking, with different baking temperatures, was performed in the Warsaw bakery, using cyclothermic deck ovens. PAHs determination was performed by high-pressure liquid chromatography with fluorescent and diode array detectors (HPLC-FLD/DAD) and confirmed by gas chromatography coupled with mass spectrometry (GC/MS). Total content of 19 PAHs in the grain, flour and bran varied from 1.07 to 3.65 μg/kg and, in bread, from 1.59 to 13.6 μg/kg depending on the part of bread and baking temperature. Based on the dough's contamination level and the influence of the baking temperature on the bread's PAHs content, it was confirmed that PAHs are formed during baking. Considering the results of the average dietary exposure to PAHs and the MOE (Margin of Exposure) analysis, it could be concluded that analysed bread and cereal products constitute little concern for consumer health. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Evaluation of Antioxidant, Anticholinesterase, and Antidiabetic Potential of Dry Leaves and Stems in Tamarix aphylla Growing Wild in Tunisia.

    PubMed

    Mahfoudhi, Adel; Grosso, Clara; Gonçalves, Rui F; Khelifi, Eltaief; Hammami, Saoussen; Achour, Sami; Trabelsi-Ayadi, Malika; Valentão, Patrícia; Andrade, Paula B; Mighri, Zine

    2016-12-01

    Tamarix aphylla (L.) Karst. has a wide geographic distribution and was employed in traditional medicine as astringent, anti-rheumatic and to treat fever. T. aphylla leaves and stems extracts were studied from both chemical and biological points of view to assess the antidiabetic, anticholinesterase and antioxidant potential of this species. The HPLC/Diode Array Detector (DAD) analysis showed the presence of 14 phenolic compounds (gallic, caffeic, p-coumaric, ferulic and ellagic acids, kaempferol, quercetin, quercetin 3-O-galactoside and six flavonol derivatives). This is the first study reporting a comparative study of the biological activities of different extracts from T. aphylla. High activities were obtained against DPPH radical, superoxide anion radical (O2∙-) and nitric oxide radical ( • NO) in a concentration-dependent manner, the most active extracts being the polar ones. T. aphylla also showed moderate protective effects against acetylcholinesterase, but no effects were observed against butyrylcholinesterase. Against α-glucosidase the MeOH extracts displayed IC 50 values from 8.41 to 24.81 μg/ml. © 2016 Wiley-VHCA AG, Zurich, Switzerland.

  3. Combination of Analytical and Chemometric Methods as a Useful Tool for the Characterization of Extra Virgin Argan Oil and Other Edible Virgin Oils. Role of Polyphenols and Tocopherols.

    PubMed

    Rueda, Ascensión; Samaniego-Sánchez, Cristina; Olalla, Manuel; Giménez, Rafael; Cabrera-Vique, Carmen; Seiquer, Isabel; Lara, Luis

    2016-01-01

    Analysis of phenolic profile and tocopherol fractions in conjunction with chemometrics techniques were used for the accurate characterization of extra virgin argan oil and eight other edible vegetable virgin oils (olive, soybean, wheat germ, walnut, almond, sesame, avocado, and linseed) and to establish similarities among them. Phenolic profile and tocopherols were determined by HPLC coupled with diode-array and fluorescence detectors, respectively. Multivariate factor analysis (MFA) and linear correlations were applied. Significant negative correlations were found between tocopherols and some of the polyphenols identified, but more intensely (P < 0.001) between the γ-tocopherol and oleuropein, pinoresinol, and luteolin. MFA revealed that tocopherols, especially γ-fraction, most strongly influenced the oil characterization. Among the phenolic compounds, syringic acid, dihydroxybenzoic acid, oleuropein, pinoresinol, and luteolin also contributed to the discrimination of the oils. According to the variables analyzed in the present study, argan oil presented the greatest similarity with walnut oil, followed by sesame and linseed oils. Olive, avocado, and almond oils showed close similarities.

  4. Cooked blueberries: anthocyanin and anthocyanidin degradation and their radical-scavenging activity.

    PubMed

    Oliveira, Carla; Amaro, L Filipe; Pinho, Olivia; Ferreira, Isabel M P L V O

    2010-08-25

    This study examined anthocyanin and anthocyanidin composition and radical-scavenging activity of three cultivars of blueberries (Vaccinium corymbosum L., cv. Bluecrop, Bluetravel, and Ozarkblue) before and after cooking. A total of 13 anthocyanins were separated and monitored in methanolic extracts of raw fruits by high-performance liquid chromatography/diode array detector (HPLC/DAD). Principal component analysis using the anthocyanin profile as variables revealed differences according to cultivar origin. Of the six common anthocyanidins, four were identified and quantified in the hydrolysates, namely, malvidin, the most abundant, followed by cyanidin, petunidin, and delphynidin. A systematic evaluation of the degradation of anthocyanins and anthocyanidins of blueberries cooked in stuffed fish was performed. The percentage of anthocyanin degradation in cooked blueberries (by progressive heating from 12 to 99 °C for 60 min) ranged between 16 and 30% for Bluecrop, 30-42% for Bluetravel, and 12-41% for Ozarkblue. However, cooked blueberries maintained or increased radical-scavenging activity when evaluated by the 1,1'-diphenyl-2-picrylhydrazyl (DPPH) method. Overall, results show that cooked blueberries can serve as a good source of bioactive phytochemicals.

  5. Determination of Yohimbine in Yohimbe Bark and Related Dietary Supplements Using UHPLC-UV/MS: Single-Laboratory Validation.

    PubMed

    Chen, Pei; Bryden, Noella

    2015-01-01

    A single-laboratory validation was performed on a practical ultra-HPLC (UHPLC)-diode array detector (DAD)/tandem MS method for determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity ethylene bridged hybrid C18 column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The method can separate corynanthine from yohimbine in yohimbe bark extract, which is critical for accurate quantitation of yohimbine in yohimbe bark and related dietary supplements. Accuracy of the method was demonstrated using standard addition methods. Both intraday and interday precisions of the method were good. The method can be used without MS since yohimbine concentration in yohimbe barks and related dietary supplements are usually high enough for DAD detection, which can make it an easy and economical method for routine analysis of yohimbe barks and related dietary supplements. On the other hand, the method can be used with MS if desired for more challenging work such as biological and/or clinical studies.

  6. Application of Silver Ion High-Performance Liquid Chromatography for Quantitative Analysis of Selected n-3 and n-6 PUFA in Oil Supplements.

    PubMed

    Czajkowska-Mysłek, Anna; Siekierko, Urszula; Gajewska, Magdalena

    2016-04-01

    The aim of this study was to develop a simple method for simultaneous determination of selected cis/cis PUFA-LNA (18:2), ALA (18:3), GLA (18:3), EPA (20:5), and DHA (22:6) by silver ion high-performance liquid chromatography coupled to a diode array detector (Ag-HPLC-DAD). The separation was performed on three Luna SCX Silver Loaded columns connected in series maintained at 10 °C with isocratic elution by 1% acetonitrile in n-hexane. The applied chromatographic system allowed a baseline separation of standard mixture of n-3 and n-6 fatty acid methyl esters containing LNA, DHA, and EPA and partial separation of ALA and GLA positional isomers. The method was validated by means of linearity, precision, stability, and recovery. Limits of detection (LOD) for considered PUFA standard solutions ranged from 0.27 to 0.43 mg L(-1). The developed method was used to evaluate of n-3 and n-6 fatty acids contents in plant and fish softgel oil capsules, results were compared with reference GC-FID based method.

  7. Stochastic resonance-enhanced laser-based particle detector.

    PubMed

    Dutta, A; Werner, C

    2009-01-01

    This paper presents a Laser-based particle detector whose response was enhanced by modulating the Laser diode with a white-noise generator. A Laser sheet was generated to cast a shadow of the object on a 200 dots per inch, 512 x 1 pixels linear sensor array. The Laser diode was modulated with a white-noise generator to achieve stochastic resonance. The white-noise generator essentially amplified the wide-bandwidth (several hundred MHz) noise produced by a reverse-biased zener diode operating in junction-breakdown mode. The gain in the amplifier in the white-noise generator was set such that the Receiver Operating Characteristics plot provided the best discriminability. A monofiber 40 AWG (approximately 80 microm) wire was detected with approximately 88% True Positive rate and approximately 19% False Positive rate in presence of white-noise modulation and with approximately 71% True Positive rate and approximately 15% False Positive rate in absence of white-noise modulation.

  8. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  9. Effect of scattered electrons on the ‘Magic Plate’ transmission array detector response

    NASA Astrophysics Data System (ADS)

    Alrowaili, Z. A.; Lerch, M.; Petasecca, M.; Carolan, M.; Rosenfeld, A.

    2017-02-01

    Transmission type detectors can provide a measure of the energy fluence and if they are real-time systems that do not significantly attenuate the radiation beam have a distinct advantage over the current method as Quality Assurance (QA) could in principle be done during the actual patient treatment. The use of diode arrays in QA holds much promise due to real-time operation and feedback when compared to other methods e.g. films which are not real-time. The goal of this work is to describe the characterization of the radiation response of a silicon diode array called the Magic Plate (MP) when operated in transmission mode (MPTM). The response linearity of MPTM was excellent (R2=1). When the MP was placed in linac block tray position; the change in PDD at phantom surface (SSD 100 cm) for a 10 × 10 cm2 was -0.037 %, -0.178 % and -0.949 % for 6 MV, 10 MV and 18 MV beams. Therefore, MP does not provide a significant increase in skin dose to the patient and the percentage depth doses showed an excellent agreement with and without MPTM for 6 MV, 10 MV and 18 MV beams.

  10. Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toltz, Allison; Hoesl, Michaela; Schuemann, Jan

    Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solidmore » water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.« less

  11. A digital optical phase-locked loop for diode lasers based on field programmable gate array.

    PubMed

    Xu, Zhouxiang; Zhang, Xian; Huang, Kaikai; Lu, Xuanhui

    2012-09-01

    We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382∕MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat note line width below 1 Hz, residual mean-square phase error of 0.14 rad(2) and transition time of 100 μs under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.

  12. A digital optical phase-locked loop for diode lasers based on field programmable gate array

    NASA Astrophysics Data System (ADS)

    Xu, Zhouxiang; Zhang, Xian; Huang, Kaikai; Lu, Xuanhui

    2012-09-01

    We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382/MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat note line width below 1 Hz, residual mean-square phase error of 0.14 rad2 and transition time of 100 μs under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.

  13. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  14. Novel Photon-Counting Detectors for Free-Space Communication

    NASA Technical Reports Server (NTRS)

    Krainak, M. A.; Yang, G.; Sun, X.; Lu, W.; Merritt, S.; Beck, J.

    2016-01-01

    We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

  15. Identification of candidate amino acids involved in the formation of pink-red pigments in onion (Allium cepa L.) juice and separation by HPLC.

    PubMed

    Lee, Eun Jin; Yoo, Kil Sun; Patil, Bhimanagouda S

    2010-10-01

    The formation of pink-red pigments ("pinking") by various amino acids was investigated by reacting amino acids with compounds present in onion juice. The unknown pink-red pigments were generated and separated using high-performance liquid chromatography (HPLC) and a diode array detector (DAD) in the range of 200 to 700 nm. To generate pink-red pigments, we developed several reaction systems using garlic alliinase, purified 1-propenyl-L-cysteine sulfoxide (1-PeCSO), onion thiosulfinate, natural onion juice, and 21 free amino acids. The compound 1-PeCSO was a key compound associated with pinking in the presence of both the alliinase and amino acids. Numerous naturally occurring pink-red pigments were detected and separated from pink onion juice using the HPLC-DAD system at 515 nm. Most free amino acids, with the exceptions of histidine, serine, and cysteine, formed various pink-red pigments when reacted with onion thiosulfinate. This observation indicated that onion pinking is caused not by a single pigment, but by many. Furthermore, more than one color compound could be produced from a single amino acid; this explains, in part, why there were many pink-red compound peaks in the chromatogram of discolored natural onion juice. We presumed that the complexity of the pink-red pigments was due to the involvement of more than 21 natural amino acids as well as several derivatives of the color products produced from each amino acid. We observed that the pinking process in onion juice is very similar to that of the greening process in crushed garlic, emphasizing that both thiosulfinate from flavor precursors and free amino acids are absolutely required for the discoloration.

  16. Simultaneous quantification of delta-9-THC, THC-acid A, CBN and CBD in seized drugs using HPLC-DAD.

    PubMed

    Ambach, Lars; Penitschka, Franziska; Broillet, Alain; König, Stefan; Weinmann, Wolfgang; Bernhard, Werner

    2014-10-01

    An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN). Copyright © 2014. Published by Elsevier Ireland Ltd.

  17. Analysis of black carbon molecular markers by two chromatographic methods (GC-FID and HPLC-DAD)

    NASA Astrophysics Data System (ADS)

    Schneider, Maximilian P. W.; Smittenberg, Rienk H.; Dittmar, Thorsten; Schmidt, Michael W. I.

    2010-05-01

    The analysis of benzenepolycarboxylic acids (BPCA) as a quantitative measure for black carbon (BC) in soil and sediment samples is a well-established method [1, 2]. Briefly, the oxidation of polycondensated BC molecules forms seven molecular markers, which can be assigned to BC, and which subsequently can be quantified by GC-FID (gas chromatography with flame ionization detector). Recently this method has been refined for BC quantification in seawater samples measuring BPCA on HPLC-DAD (High performance liquid chromatography with diode array detector) [3]. However, a systematic comparison of BC as determined by both analytical techniques would be essential to the calculation of global BC budgets, but is lacking. Here we present data for the systematic comparison of the two BPCA methods, both for quantity and quality. We prepared chars under well-defined laboratory conditions. Chestnut hardwood chips and rice straw were pyrolysed at temperatures between 200 and 1000°C under constant N2 stream. The BC contents of the chars have been analysed using the BPCA extraction method followed by either GC-FID or HPLC-DAD quantification [4]. It appears that the GC-FID method yields systematically lower concentrations of BPCA in the chars compared to the HPLC-DAD method. Possible reasons for the observed difference are i) higher losses of sample material during preparation for GC-FID; ii) different quality of the linear regression used for quantification; iii) incomplete derivatisation of B5CA and B6CA, which is needed for GC-FID analysis. In a next step, we will test different derivatisation procedures (methylation with dimethyl sulfate or diazomethane, and silylation) for their influence on the GC-FID results. The aim of this study is to test if black carbon can be quantified in soil, sediment and water samples using one single method - a crucial step when attempting a global BC budget. References: [1] Brodowski, S., Rodionov, A., Haumeier L., Glaser, B., Amelung, W. (2005) Org. Geochem. 36, 1299-1310. [2] Glaser, B., Haumeier, L., Guggenberger, G., Zech, W. (1998) Org. Geochem. 29, 811-819. [3] Dittmar, T. (2008) Org. Geochem. 39. 396-407. [4] Schneider, M.P.W., Hilf, M., Vogt, U.F., Schmidt, M.W.I., Org. Geochem. (submitted)

  18. Characterization and quantification of flavonoids and saponins in adzuki bean (Vigna angularis L.) by HPLC-DAD-ESI-MSn analysis.

    PubMed

    Liu, Rui; Cai, Zongwei; Xu, Baojun

    2017-09-22

    Bioactive activities of adzuki bean have been widely reported, however, the phytochemical information of adzuki bean is incomplete. The aim of this study was to characterize and quantify flavonoids and saponins in adzuki bean. High performance liquid chromatography with diode array detection and electro spray ionization-tandem multi-stage mass spectrometry (HPLC-DAD-ESI-MS n ) were applied to do qualitative and quantitative analyses. A total of 15 compounds from adzuki bean were identified by HPLC-DAD-ESI-MS n . Among 15 compounds identified, four flavonoids (catechin, vitexin-4″-O-glucoside, quercetin-3-O-glucoside, and quercetin-3-O-rutinoside) and six saponins (azukisaponin I, II, III, IV, V, and VI) in adzuki bean were further quantified by external calibration method using HPLC-MS with the program of time segment and extract ion chromatogram (EIC) analysis. Current qualitative and quantitative method based on HPLC and MS technique provides a scientific basis for in vitro and in vivo pharmacological study in the future. Graphical abstract Isolation and characterization of flavonoids and saponins from adzuki bean.

  19. Utilization of aromatic compounds by the Penicillium strain Bi 7/2.

    PubMed

    Hofrichter, M; Scheibner, K

    1993-01-01

    The Penicillium strain Bi 7/2 utilized phenol, catechol, resorcinol, hydroquinone, pyrogallol, hydroxyhydroquinone, phloroglucinol, m- and p-cresol, orcinol, 4-methylcatechol, 4-methoxyphenol, 4-aminophenol, benzyl alcohol, benzoic acid, 2-, 3- and 4-hydroxybenzoic acid, anthranilic acid, protocatechuic acid and gallic acid as sole sources of carbon and energy. The central metabolites catechol, protocatechuic acid and hydroxyquinone could be determined by HPLC with diode-array detection. Pathways for the degradation of aromatic substances were proposed.

  20. Separation and quantification of 15 carotenoids by reversed phase high performance liquid chromatography coupled to diode array detection with isosbestic wavelength approach.

    PubMed

    Mitrowska, Kamila; Vincent, Ursula; von Holst, Christoph

    2012-04-13

    The manuscript presents the development of a new reverse phase high performance liquid chromatography (RP-HPLC) photo diode array detection method allowing the separation and quantification of 15 carotenoids (adonirubin, adonixanthin, astaxanthin, astaxanthin dimethyl disuccinate, asteroidenone, beta-apo-8'-carotenal, beta-apo-8'-carotenoic acid ethyl ester, beta-carotene, canthaxanthin, capsanthin, citranaxanthin, echinenone, lutein, lycopene, and zeaxanthin), 10 of which are feed additives authorised within the European Union. The developed method allows for the reliable determination of the total carotenoid content in one run using the corresponding E-isomer as calibration standard while taking into account the E/Z-isomers composition. This is a key criterion for the application of the method, since for most of the analytes included in this study analytical standards are only available for the E-isomers. This goal was achieved by applying the isosbestic concept, in order to identify specific wavelengths, at which the absorption coefficients are identical for all stereoisomers concerned. The second target referred to the optimisation of the LC conditions. By means of an experimental design, an optimised RP-HPLC method was developed allowing for a sufficient chromatographic separation of all carotenoids. The selected method uses a Suplex pKb-100 HPLC column and applying a gradient with a mixture of acetonitrile, tert-butyl-methyl ether and water as mobile phases. The limits of detection and limits of quantification ranged from 0.06 mg L(-1) to 0.14 mg L(-1) and from 0.20 mg L(-1) to 0.48 mg L(-1), respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    PubMed

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  2. Simultaneous determination of six bioactive compounds in Evodiae Fructus by high-performance liquid chromatography with diode array detection.

    PubMed

    Tang, Xiaolong; Huang, Zhifang; Chen, Yan; Liu, Yunhua; Liu, Yuhong; Zhao, Junning; Yi, Jinhai

    2014-02-01

    A simple and reliable high-performance liquid chromatography method with diode array detection (HPLC-DAD) was developed and validated for the simultaneous determination of six bioactive components, rutaevine, limonin, evodiamine, rutaecarpine, N-formyldihydrorutaecarpine and dihydroevocarpine, in the traditional Chinese medicine Evodiae Fructus (Wuzhuyu in Chinese). HPLC separation was conducted on an Agilent Eclipse C18 column (4.6 × 150 mm, 5 µm) at 35°C with a mixture of mobile phase A [tetrahydrofuran-0.02% phosphoric acid (16 : 35)] and mobile phase B (acetonitrile) (gradient elution as follows: 0 min, 22% B; 23 min, 22% B; 24 min, 75% B) at a flow rate of 1 mL/min, and the DAD detection wavelength was set at 220 nm. A linear relationship within the range of investigated concentrations was observed for the six compounds, with correlation coefficients greater than 0.999. The average recovery yields of the six compounds ranged from 98.39 to 104.96%. The HPLC-DAD method was validated by its repeatability [relative standard deviation (RSD) < 2.0%] and intra-day and inter-day precision (RSD < 2.0%). The method was successfully applied to the simultaneous determination of the six previously mentioned components in Evodiae Fructus. It is the first report of a simultaneous qualitative and quantitative analysis for three classes of bioactive components in Wuzhuyu, including the indolequinazoline alkaloids, quinolone alkaloid and limonoids. Based on these results, it is suggested, for possible future revision of the Chinese Pharmacopoeia, that the total contents of evodiamine and rutaecarpine are not less than 0.15% and the total contents of rutaevine and limonin are not less than 0.50%.

  3. Application of high performance liquid chromatography for the profiling of complex chemical mixtures with the aid of chemometrics.

    PubMed

    Ni, Yongnian; Zhang, Liangsheng; Churchill, Jane; Kokot, Serge

    2007-06-15

    In this paper, chemometrics methods were applied to resolve the high performance liquid chromatography (HPLC) fingerprints of complex, many-component substances to compare samples from a batch from a given manufacturer, or from those of different producers. As an example of such complex substances, we used a common Chinese traditional medicine, Huoxiang Zhengqi Tincture (HZT) for this research. Twenty-one samples, each representing a separate HZT production batch from one of three manufacturers were analyzed by HPLC with the aid of a diode array detector (DAD). An Agilent Zorbax Eclipse XDB-C18 column with an Agilent Zorbax high pressure reliance cartridge guard-column were used. The mobile phase consisted of water (A) and methanol (B) with a gradient program of 25-65% (v/v, B) during 0-30min, 65-55% (v/v, B) during 30-35min and 55-100% (v/v, B) during 35-60min (flow rate, 1.0mlmin(-1); injection volume, 20mul; and column temperature-ambient). The detection wavelength was adjusted for maximum sensitivity at different time periods. A peak area matrix with 21objectsx14HPLC variables was obtained by sampling each chromatogram at 14 common retention times. Similarities were then calculated to discriminate the batch-to-batch samples and also, a more informative multi-criteria decision making methodology (MCDM), PROMETHEE and GAIA, was applied to obtain more information from the chromatograms in order to rank and compare the complex HZT profiles. The results showed that with the MCDM analysis, it was possible to match and discriminate correctly the batch samples from the three different manufacturers. Fourier transform infrared (FT-IR) spectra taken from samples from several batches were compared by the common similarity method with the HPLC results. It was found that the FT-IR spectra did not discriminate the samples from the different batches.

  4. Focal-plane detector system for the KATRIN experiment

    NASA Astrophysics Data System (ADS)

    Amsbaugh, J. F.; Barrett, J.; Beglarian, A.; Bergmann, T.; Bichsel, H.; Bodine, L. I.; Bonn, J.; Boyd, N. M.; Burritt, T. H.; Chaoui, Z.; Chilingaryan, S.; Corona, T. J.; Doe, P. J.; Dunmore, J. A.; Enomoto, S.; Formaggio, J. A.; Fränkle, F. M.; Furse, D.; Gemmeke, H.; Glück, F.; Harms, F.; Harper, G. C.; Hartmann, J.; Howe, M. A.; Kaboth, A.; Kelsey, J.; Knauer, M.; Kopmann, A.; Leber, M. L.; Martin, E. L.; Middleman, K. J.; Myers, A. W.; Oblath, N. S.; Parno, D. S.; Peterson, D. A.; Petzold, L.; Phillips, D. G.; Renschler, P.; Robertson, R. G. H.; Schwarz, J.; Steidl, M.; Tcherniakhovski, D.; Thümmler, T.; Van Wechel, T. D.; VanDevender, B. A.; Vöcking, S.; Wall, B. L.; Wierman, K. L.; Wilkerson, J. F.; Wüstling, S.

    2015-04-01

    The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

  5. Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

    PubMed

    Chen, Pei; Atkinson, Renata; Wolf, Wayne R

    2009-01-01

    The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.

  6. Single-Laboratory Validation of a High-Performance Liquid Chromatographic-Diode Array Detector-Fluorescence Detector/Mass Spectrometric Method for Simultaneous Determination of Water-Soluble Vitamins in Multivitamin Dietary Tablets

    PubMed Central

    Chen, Pei; Atkinson, Renata; Wolf, Wayne R.

    2014-01-01

    The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 µm, 250 × 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLD/MS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration. PMID:19485230

  7. Hanging drop crystal growth apparatus

    NASA Technical Reports Server (NTRS)

    Naumann, Robert J. (Inventor); Witherow, William K. (Inventor); Carter, Daniel C. (Inventor); Bugg, Charles E. (Inventor); Suddath, Fred L. (Inventor)

    1990-01-01

    This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

  8. Piper betle leaves: profiling phenolic compounds by HPLC/DAD-ESI/MS(n) and anti-cholinesterase activity.

    PubMed

    Ferreres, Federico; Oliveira, Andreia P; Gil-Izquierdo, Angel; Valentão, Patrícia; Andrade, Paula B

    2014-01-01

    Piper betle L. is a widely distributed plant in the tropical and subtropical regions, its leaves being largely consumed as a masticator and mouth freshener. The purposes of this work were to characterise the phenolic profile of this species and to improve knowledge of its anti-cholinesterase properties. The phenolic composition of P. betle leaf aqueous and ethanol extracts was characterised by HPLC coupled with a diode-array detector and combined with electrospray ionisation tandem MS, and in vitro cholinesterase inhibitory capacity of both extracts was assessed by spectrophotometric microassays. The effect on neuronal cells (SH-SY5Y) viability was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide reduction and lactate dehydrogenase leakage. Twelve phenolic compounds, comprising a phenylpropanoid, five cinnamoyl and six flavonoids derivatives were identified in P. betle leaves. Hydroxychavicol was the major compound in both extracts; however, the aqueous extract presented a greater diversity of compounds. Both extracts showed strong activity against both acetyl- and butyrylcholinesterase, which can be due, at least partially, to the phenolic composition. Furthermore, the aqueous extract proved to be cytotoxic to human neuroblastoma cells at concentrations higher than 500 µg/mL. The results suggest that the consumption of P. betle leaves as an infusion can have a positive impact in the prevention and treatment of neurodegenerative diseases. Apigenin and luteolin derivatives are reported for the first time in this species. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Valuing the Endangered Species Antirrhinum lopesianum: Neuroprotective Activities and Strategies for in vitro Plant Propagation.

    PubMed

    Gomes, Andreia; Fortalezas, Sofia; Pimpão, Rui; Figueira, Inês; Maroco, João; Aguiar, Carlos; Ferreira, Ricardo B; Miguel, Célia; Santos, Cláudia N

    2013-10-28

    Plant phytochemicals are described as possessing considerable neuroprotective properties, due to radical scavenging capacity and acetylcholinesterase inhibitory activity, important bioactivities in neurodegeneration. Antirrhinum lopesianum is a rare endemism from the Iberian Peninsula, occurring at the northeastern border between Portugal and Spain. It is classified as Endangered, due to its highly fragmented geographical occupation, facing a high risk of extinction in the Portuguese territory, within 20 years. Here, we describe for the first time the chemical characterization of extracts of the species concerning total phenol content, flavonoid content and antioxidant properties. The profile of high performance liquid chromatography with diode array detector (HPLC-DAD) of the polyphenol-enriched fraction of plant extracts was also performed, showing the great potential of the species as a source of bioactive phytochemical compounds. A. lopesianum's potential for neuroprotection was revealed by a significant acetylcholinesterase inhibitory activity and also by a neuroprotective effect on a human cell model of neurodegeneration. Moreover, this is the first report describing a successful procedure for the in vitro propagation of this endangered species. The comparison of phenolic content and the HPLC-DAD profile of wild and in vitro propagated plants revealed that in vitro plants maintain the ability to produce secondary metabolites, but the profiles are differentially affected by the growth regulators. The results presented here greatly contribute to the value for this species regarding its potential as a source of phytochemicals with prospective neuroprotective health benefits.

  10. Determination of six sulfonylurea herbicides in environmental water samples by magnetic solid-phase extraction using multi-walled carbon nanotubes as adsorbents coupled with high-performance liquid chromatography.

    PubMed

    Ma, Jiping; Jiang, Lianhua; Wu, Gege; Xia, Yan; Lu, Wenhui; Li, Jinhua; Chen, Lingxin

    2016-09-30

    Magnetic solid-phase extraction (MSPE) using magnetic multi-walled carbon nanotubes (mag-MWCNTs) as adsorbents, coupled with high-performance liquid chromatography-diode-array detector (HPLC-DAD), was developed for the simultaneous separation and determination of six types of sulfonylurea herbicides (SUs) in environmental water samples. Several variables affecting MSPE efficiency were systematically investigated, including the type and volume of desorption solvent, sample solution pH, salt concentration, amount of mag-MWCNTs, and extraction and desorption time. Response surface was employed to assist in the MSPE optimization. Under optimized conditions, excellent linearity was achieved in the range of 0.05-5.0μg/L for all six SUs, with coefficients of correlation r>0.9994, and preconcentration factors ranging from 178 to 210. Limits of detection and quantification were 0.01-0.04μg/L and 0.03-0.13μg/L, respectively. The intra-day and inter-day precision (relative standard deviations, n=6, %) at three spiked levels were 2.0-11.0% and 2.1-12.9% in terms of peak area, respectively. The method recoveries at three fortified concentrations were obtained within 76.7-106.9% for reservoir water samples and 78.2-105.4% for tap water samples. The developed MSPE-HPLC method demonstrated high sensitivity, repeatability, simplicity, rapidity, and excellent practical applicability. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Phenolic-rich extracts of Eurycoma longifolia and Cylicodiscus gabunensis inhibit enzymes responsible for the development of erectile dysfunction and are antioxidants.

    PubMed

    Oboh, Ganiyu; Adebayo, Adeniyi A; Ademosun, Ayokunle O

    2018-05-19

    Herbs have been used from ages to manage male sexual dysfunction. Hence, this study sought to investigate the effects of Eurycoma longifolia (EL) and Cylicodiscus gabunensis (CG) stem bark extracts on some enzymes implicated in erectile dysfunction in vitro. The extracts were prepared, and their effects on phosphodiesterase-5 (PDE-5), arginase, and angiotensin-1-converting enzyme (ACE) as well as pro-oxidant-induced lipid peroxidation were assessed. Furthermore, phenolic contents were determined, and their components were characterized and quantified using high-performance liquid chromatography with diode array detector (HPLC-DAD). The results revealed that the extracts inhibited PDE-5, arginase, and ACE in a concentration-dependent manner. However, IC50 values revealed that CG had higher inhibitory potential on PDE-5 (IC50=204.4 μg/mL), arginase (IC50=39.01 μg/mL), and ACE (IC50=48.81 μg/mL) than EL. In addition, the extracts inhibited pro-oxidant-induced lipid peroxidation in penile tissue homogenate. HPLC-DAD analysis showed that CG is richer in phenolic compounds than EL, and this could be responsible for higher biological activities observed in CG than EL. Hence, the observed antioxidant property and inhibitory action of CG and EL on enzymes relevant to erectile dysfunction in vitro could be part of possible mechanisms underlying their involvement in traditional medicine for the management of male sexual dysfunction.

  12. Variability of some diterpene esters in coffee beverages as influenced by brewing procedures.

    PubMed

    Moeenfard, Marzieh; Erny, Guillaume L; Alves, Arminda

    2016-11-01

    Several coffee brews, including classical and commercial beverages, were analyzed for their diterpene esters content (cafestol and kahweol linoleate, oleate, palmitate and stearate) by high performance liquid chromatography with diode array detector (HPLC-DAD) combined with spectral deconvolution. Due to the coelution of cafestol and kahweol esters at 225 nm, HPLC-DAD did not give accurate quantification of cafestol esters. Accordingly, spectral deconvolution was used to deconvolve the co-migrating profiles. Total cafestol and kahweol esters content of classical coffee brews ranged from 5-232 to 2-1016 mg/L, respectively. Commercial blends contained 1-54 mg/L of total cafestol esters and 2-403 mg/L of total kahweol esters. Boiled coffee had the highest diterpene esters content, while filtered and instant brews showed the lowest concentrations. However, individual diterpene esters content was not affected by brewing procedure as in terms of kahweol esters, kahweol palmitate was the main compound in all samples, followed by kahweol linoleate, oleate and stearate. Higher amounts of cafestol palmitate and stearate were also observed compared to cafestol linoleate and cafestol oleate. The ratio of diterpene esters esterified with unsaturated fatty acids to total diterpene esters was considered as measure of their unsaturation in analyzed samples which varied from 47 to 52%. Providing new information regarding the diterpene esters content and their distribution in coffee brews will allow a better use of coffee as a functional beverage.

  13. Valuing the Endangered Species Antirrhinum lopesianum: Neuroprotective Activities and Strategies for in vitro Plant Propagation

    PubMed Central

    Gomes, Andreia; Fortalezas, Sofia; Pimpão, Rui; Figueira, Inês; Maroco, João; Aguiar, Carlos; Ferreira, Ricardo B.; Miguel, Célia; Santos, Cláudia N.

    2013-01-01

    Plant phytochemicals are described as possessing considerable neuroprotective properties, due to radical scavenging capacity and acetylcholinesterase inhibitory activity, important bioactivities in neurodegeneration. Antirrhinum lopesianum is a rare endemism from the Iberian Peninsula, occurring at the northeastern border between Portugal and Spain. It is classified as Endangered, due to its highly fragmented geographical occupation, facing a high risk of extinction in the Portuguese territory, within 20 years. Here, we describe for the first time the chemical characterization of extracts of the species concerning total phenol content, flavonoid content and antioxidant properties. The profile of high performance liquid chromatography with diode array detector (HPLC-DAD) of the polyphenol-enriched fraction of plant extracts was also performed, showing the great potential of the species as a source of bioactive phytochemical compounds. A. lopesianum’s potential for neuroprotection was revealed by a significant acetylcholinesterase inhibitory activity and also by a neuroprotective effect on a human cell model of neurodegeneration. Moreover, this is the first report describing a successful procedure for the in vitro propagation of this endangered species. The comparison of phenolic content and the HPLC-DAD profile of wild and in vitro propagated plants revealed that in vitro plants maintain the ability to produce secondary metabolites, but the profiles are differentially affected by the growth regulators. The results presented here greatly contribute to the value for this species regarding its potential as a source of phytochemicals with prospective neuroprotective health benefits. PMID:26784465

  14. Determination of phthalates released from paper packaging materials by solid-phase extraction-high-performance liquid chromatography.

    PubMed

    Gao, Xin; Yang, Bofeng; Tang, Zhixu; Luo, Xin; Wang, Fengmei; Xu, Hui; Cai, Xue

    2014-01-01

    A solid phase extraction (SPE) high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of 10 phthalic acid esters (dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzylbutyl phthalate, diisobutyl phthalate, dicyclohexyl phthalate, diamyl phthalate, di-n-hexyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate) released from food paper packaging materials. The use of distilled water, 3% acetic acid (w/v), 10% ethanol (v/v) and 95% ethanol (v/v) instead of the different types of food simulated the migration of 10 phthalic acid esters from food paper packaging materials; the phthalic acid esters in four food simulants were enriched and purified by a C18 SPE column and nitrogen blowing, and quantified by HPLC with a diode array detector. The chromatographic conditions and extraction conditions were optimized and all 10 of the phthalate acid esters had a maximum absorbance at 224 nm. The method showed limitations of detection in the range of 6.0-23.8 ng/mL the correlation coefficients were greater than 0.9999 in all cases, recovery values ranged between 71.27 and 106.97% at spiking levels of 30, 60 and 90 ng/mL and relative standard deviation values ranged from 0.86 to 8.00%. The method was considered to be simple, fast and reliable for a study on the migration of these 10 phthalic acid esters from food paper packaging materials into food.

  15. In-Syringe Micro Solid-Phase Extraction Method for the Separation and Preconcentration of Parabens in Environmental Water Samples.

    PubMed

    Mashile, Geaneth Pertunia; Mpupa, Anele; Nomngongo, Philiswa Nosizo

    2018-06-14

    In this study, a simple, rapid and effective in-syringe micro-solid phase extraction (MSPE) method was developed for the separation and preconcetration of parabens (methyl, ethyl, propyl and butyl paraben) in environmental water samples. The parabens were determined and quantified using high performance liquid chromatography and a photo diode array detector (HPLC-PDA). Chitosan-coated activated carbon (CAC) was used as the sorbent in the in-syringe MSPE device. A response surface methodology based on central composite design was used for the optimization of factors (eluent solvent type, eluent volume, number of elution cycles, sample volume, sample pH) affecting the extraction efficiency of the preconcentration procedure. The adsorbent used displayed excellent absorption performance and the adsorption capacity ranged from 227⁻256 mg g −1 . Under the optimal conditions the dynamic linear ranges for the parabens were between 0.04 and 380 µg L −1 . The limits of detection and quantification ranged from 6⁻15 ng L −1 and 20⁻50 ng L −1 , respectively. The intraday (repeatability) and interday (reproducibility) precisions expressed as relative standard deviations (%RSD) were below 5%. Furthermore, the in-syringe MSPE/HPLC procedure was validated using spiked wastewater and tap water samples and the recoveries ranged between from 96.7 to 107%. In conclusion, CAC based in-syringe MSPE method demonstrated great potential for preconcentration of parabens in complex environmental water.

  16. RP-HPLC method development and validation for simultaneous estimation of atorvastatin calcium and pioglitazone hydrochloride in pharmaceutical dosage form.

    PubMed

    Peraman, Ramalingam; Mallikarjuna, Sasikala; Ammineni, Pravalika; Kondreddy, Vinod kumar

    2014-10-01

    A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 μm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Validated Chromatographic Methods for the Analysis of Two Binary Mixtures Containing Pyridoxine Hydrochloride.

    PubMed

    Habib, Neven M; Abdelrahman, Maha M; Abdelwhab, Nada S; Ali, Nourudin W

    2017-03-01

    Accurate and precise TLC-densitometric and HPLC-diode-array detector (DAD) methods have been developed and validated to resolve two binary mixtures containing pyridoxine hydrochloride (PYH) with either cyclizine hydrochloride (CYH) or meclizine hydrochloride (MEH). In the developed TLC-densitometric method, chromatographic separation of the three studied drugs was carried out on silica gel 60 F254 plates using a developing system containing methylene chloride + acetone + methanol (7 + 1 + 0.5, v/v/v) scanning separated bands at 220 nm. Beer-Lambert law was obeyed in the ranges of 0.2-5, 0.2-4, and 0.2-4 µg/band for PYH, CYH, and MEH, respectively. On the other hand, the developed HPLC-DAD method depended on chromatographic separation on a Zorbax Eclipse C18 column using methanol-KH2PO4 (0.05 M; 90 + 10, v/v; pH 5, with H3PO4 and KOH) as the mobile phase, a flow rate of 1 mL/min, and UV scanning at 220 nm. A linear relationship was obtained between the integrated peak area and the concentration in the ranges of 10-50, 10-50, and 7-50 µg/mL for PYH, CYH, and MEH, respectively. The proposed methods were successfully applied for the determination of the cited drugs in their pharmaceutical formulations. Statistical comparison with the reported methods using Student's t- and F-tests found there were no significant differences between the proposed and reported methods for accuracy and precision.

  18. Miniaturized high throughput detection system for capillary array electrophoresis on chip with integrated light emitting diode array as addressed ring-shaped light source.

    PubMed

    Ren, Kangning; Liang, Qionglin; Mu, Xuan; Luo, Guoan; Wang, Yiming

    2009-03-07

    A novel miniaturized, portable fluorescence detection system for capillary array electrophoresis (CAE) on a microfluidic chip was developed, consisting of a scanning light-emitting diode (LED) light source and a single point photoelectric sensor. Without charge coupled detector (CCD), lens, fibers and moving parts, the system was extremely simplified. Pulsed driving of the LED significantly increased the sensitivity, and greatly reduced the power consumption and photobleaching effect. The highly integrated system was robust and easy to use. All the advantages realized the concept of a portable micro-total analysis system (micro-TAS), which could work on a single universal serial bus (USB) port. Compared with traditional CAE detecting systems, the current system could scan the radial capillary array with high scanning rate. An 8-channel CAE of fluorescein isothiocyanate (FITC) labeled arginine (Arg) on chip was demonstrated with this system, resulting in a limit of detection (LOD) of 640 amol.

  19. The carotenoid pigments of a marine Bacillus firmus strain.

    PubMed

    Pane, L; Radin, L; Franconi, G; Carli, A

    1996-01-01

    As carotenoids have important biological functions, it is important to discover new natural sources of these pigments. The bacterial strains isolated from a sea water rock pool were cultivated on marine agar containing yeast extract and identified by conventional methods. The bacterial pigments were extracted with methanol and analyzed by reversed-phase HPLC with diode array detection. The major pigment of a Bacillus firmus strain was identified as astaxanthin; the results obtained suggest potential use of this bacterium in aquaculture and in pharmaceutical field.

  20. Flame monitoring of a model swirl injector using 1D tunable diode laser absorption spectroscopy tomography

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Cao, Zhang; Li, Fangyan; Lin, Yuzhen; Xu, Lijun

    2017-05-01

    Distributions of temperature and H2O concentration in a swirling flame are critical to evaluate the performance of a gas turbine combustor. In this paper, 1D tunable diode laser absorption spectroscopy tomography (1D-TDLAST) was introduced to monitor swirling flames generated from a model swirl injector by simultaneously reconstructing the rotationally symmetric distributions of temperature and H2O concentration. The optical system was sufficiently simplified by introducing only one fan-beam illumination and a linear detector array of 12 equally-spaced photodetectors. The fan-beam illumination penetrated a cross section of interest in the swirling flame and the transmitted intensities were detected by the detector array. With the transmitted intensities in hand, projections were extracted and employed by a 1D tomographic algorithm to reconstruct the distributions of temperature and H2O concentration. The route of the precessing vortex core generated in the swirling flame can be easily inferred from the reconstructed profiles of temperature and H2O concentration at different heights above the nozzle of the swirl injector.

  1. Focal-plane detector system for the KATRIN experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amsbaugh, J. F.; Barrett, J.; Beglarian, A.

    Here, the local plane detector system for the KArlsiuhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high vacuum system, a high vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system, It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

  2. Focal-plane detector system for the KATRIN experiment

    DOE PAGES

    Amsbaugh, J. F.; Barrett, J.; Beglarian, A.; ...

    2015-01-09

    Here, the local plane detector system for the KArlsiuhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high vacuum system, a high vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system, It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

  3. High-performance liquid chromatography analysis of plant saponins: An update 2005-2010

    PubMed Central

    Negi, Jagmohan S.; Singh, Pramod; Pant, Geeta Joshi Nee; Rawat, M. S. M.

    2011-01-01

    Saponins are widely distributed in plant kingdom. In view of their wide range of biological activities and occurrence as complex mixtures, saponins have been purified and separated by high-performance liquid chromatography using reverse-phase columns at lower wavelength. Mostly, saponins are not detected by ultraviolet detector due to lack of chromophores. Electrospray ionization mass spectrometry, diode array detector , evaporative light scattering detection, and charged aerosols have been used for overcoming the detection problem of saponins. PMID:22303089

  4. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    USDA-ARS?s Scientific Manuscript database

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  5. Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI-LINAC systems.

    PubMed

    Gargett, Maegan; Oborn, Brad; Metcalfe, Peter; Rosenfeld, Anatoly

    2015-02-01

    MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named "magic plate," for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. geant4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm(3)) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm(2) area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm(2) photon field size. The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI-linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

  6. Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gargett, Maegan, E-mail: mg406@uowmail.edu.au; Rosenfeld, Anatoly; Oborn, Brad

    2015-02-15

    Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-linemore » and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.« less

  7. Simultaneous determination of seven lignans in Justicia procumbens by high performance liquid chromatography-photodiode array detection using relative response factors.

    PubMed

    Luo, Zuliang; Kong, Weijun; Qiu, Feng; Yang, Meihua; Li, Qian; Wei, Riwei; Yang, Xiaoli; Qin, Jieping

    2013-02-01

    A simple and sensitive HPLC coupled with photodiode array (HPLC-PDA) method was developed for simultaneous determination of seven lignans in Justicia procumbens using relative response factors (RRFs). The chromatographic separation was performed on a Shiseido Capcell Pak C(18) column (250 × 4.6 mm id, 5 μm), a gradient elution of acetonitrile/water, and a photodiode array detector. The column temperature was maintained at 35°C and the detection wavelength was set at 256 nm. Chinensinaphthol methyl ether was selected as the reference compound for calculating the relative response factors of the lignans. It has shown that the RRFs for lignans are quite similar at 256 nm of detection under different analytical conditions (different columns and HPLC instruments). Using RRFs, not every lignan is needed as a reference standard, making the method ideal for rapid, routine analysis, especially for those laboratories where lignans standards are not readily available. An economic and practicable HPLC method using RRFs was established for the determination of seven lignans in J. procumbens. This method not only can determine multiple indexes in traditional Chinese medicines (TCMs) simultaneously, but also resolve the problem of lacking of chemical standards. It will be a good quality evaluation method and pattern for TCMs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A digital optical phase-locked loop for diode lasers based on field programmable gate array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu Zhouxiang; Zhang Xian; Huang Kaikai

    2012-09-15

    We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382/MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat notemore » line width below 1 Hz, residual mean-square phase error of 0.14 rad{sup 2} and transition time of 100 {mu}s under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.« less

  9. High-performance liquid chromatography-diode array detection-electrospray ionization multi-stage mass spectrometric screening of an insect/plant system: the case of Spodoptera littoralis/Lycopersicon esculentum phenolics and alkaloids.

    PubMed

    Ferreres, Federico; Taveira, Marcos; Gil-Izquierdo, Angel; Oliveira, Luísa; Teixeira, Tânia; Valentão, Patrícia; Simões, Nelson; Andrade, Paula B

    2011-07-30

    High-performance liquid chromatography-diode array detection-electrospray ionization multi-stage mass spectrometry (HPLC-DAD-ESI-MS(n)) is considered to be a very valuable tool for the characterization of compounds found in trace amounts in natural matrices, as their previous isolation and clean-up steps can be avoided. Micro-scale separation increases the potential of this analytical technique, allowing the determination of compounds in reduced samples. Spodoptera littoralis represents a major challenge to Solanaceae plants, as it is one of the most deleterious pests. The S. littoralis/Lycopersicon esculentum system was studied for the first time concerning glycoalkaloids and phenolics. Using HPLC-DAD-ESI-MS(n) we were able to characterize 15 phenolic compounds in L. esculentum leaves. Nine of them are reported for the first time. Some differences were found between leaves of cerasiforme and 'Bull's heart' varieties. However, in the materials of S. littoralis (larvae, adults, exuviae and excrements) reared in both L. esculentum leaves no phenolics were identified. α-Tomatine was the main glycoalkaloid in the host plant. The glycoalkaloid composition of the different S. littoralis materials was distinct, with α-tomatine and dehydrotomatine being the main detected compounds in larvae and excrements. These results add knowledge to the ecological interaction in this insect/plant duo, for which it is hard to obtain considerable sample amounts. Copyright © 2011 John Wiley & Sons, Ltd.

  10. High-speed separation and characterization of major constituents in Radix Paeoniae Rubra by fast high-performance liquid chromatography coupled with diode-array detection and time-of-flight mass spectrometry.

    PubMed

    Liu, E-Hu; Qi, Lian-Wen; Li, Bin; Peng, Yong-Bo; Li, Ping; Li, Chang-Yin; Cao, Jun

    2009-01-01

    A fast high-performance liquid chromatography (HPLC) method coupled with diode-array detection (DAD) and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) has been developed for rapid separation and sensitive identification of major constituents in Radix Paeoniae Rubra (RPR). The total analysis time on a short column packed with 1.8-microm porous particles was about 20 min without a loss in resolution, six times faster than the performance of a conventional column analysis (115 min). The MS fragmentation behavior and structural characterization of major compounds in RPR were investigated here for the first time. The targets were rapidly screened from RPR matrix using a narrow mass window of 0.01 Da to restructure extracted ion chromatograms. Accurate mass measurements (less than 5 ppm error) for both the deprotonated molecule and characteristic fragment ions represent reliable identification criteria for these compounds in complex matrices with similar if not even better performance compared with tandem mass spectrometry. A total of 26 components were screened and identified in RPR including 11 monoterpene glycosides, 11 galloyl glucoses and 4 other phenolic compounds. From the point of time savings, resolving power, accurate mass measurement capability and full spectral sensitivity, the established fast HPLC/DAD/TOFMS method turns out to be a highly useful technique to identify constituents in complex herbal medicines. (c) 2008 John Wiley & Sons, Ltd.

  11. Monitoring of biogenic amines and drugs of various therapeutic groups in urine samples with use of HPLC.

    PubMed

    Baranowska, Irena; Płonka, Joanna

    2016-04-01

    A high-performance liquid chromatography method for simultaneous separation and determination of biogenic amines [dopamine, epinephrine, serotonin and its six metabolites (normetanephrine, metanephrine, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol, homovanilic acid and 5-hydroxyindoloacetic acid)] with drugs from different therapeutically groups [analgesics (paracetamol, metamizol), diuretics (furosemide) and antibiotics (cefazolin, fluconazole)] was developed. A chromatographic column with pre-column with octadecylsilane phase (C18e ) and two detectors - diode array serial connected and fluorescence - was used. Gradient elution of mixture of acetate buffer (pH 4.66) and methanol as a mobile phase was applied. The limit of detection (LOD) of 8-10 ng/mL and limit of quantitation (LOQ) of 24-30 ng/mL for biogenic amines, as well as the LOD of 50-100 ng/mL and the LOQ of 150-300 ng/mL for drugs, were determined. The applied sample preparation method allowed recoveries of 93% for the biogenic amines and 92% for the drugs to be achieved. The developed procedure has been applied to simultaneous determination of the examined compounds in urine samples and could be used in clinical analysis. Copyright © 2015 John Wiley & Sons, Ltd.

  12. [Simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using solid phase extraction-reversed-phase high performance liquid chromatography].

    PubMed

    Zhang, Hua; Yang, Xin; Ma, Ying; Dong, Aijun; Zhang, Yingchun

    2008-05-01

    A method was developed for the simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using reversed-phase high performance liquid chromatography (RP-HPLC). The sample was extracted by acetonitrile, and cleaned up by an LC-NH2 column. An Agilent ZORBAX Eclipse XDB-C18 analytical column (150 mm x 4.6 mm, 5 microm) was used and kept at 25 degrees C. Acetonitrile-methanol (95 : 5, v/v) was used as the mobile phase at a flow rate of 1.0 mL/min. The detection was performed by a diode array detector at 474 nm. The quantitive analysis of external standard calibration curves was used. The linear ranges of the method for canthaxanthin and astaxanthin were 1.0 - 30.0 mg/L (r = 0.999 0) and 1.0 - 20.0 mg/L (r = 0.999 1), respectively. The average recoveries were 90% - 101% with the relative standard deviations of 0.62% - 3.68%. The detection limits were 0.84 and 0.60 mg/L for canthaxanthin and astaxanthin, respectively. The method is simple, precise, sensitive and reproductive. It can be used to determine the contents of canthaxanthin and astaxanthin in feedstuffs.

  13. HPLC method for the simultaneous quantification of the major organic acids in Angeleno plum fruit

    NASA Astrophysics Data System (ADS)

    Wang, Yanwei; Wang, Jing; Cheng, Wei; Zhao, Zhilei; Cao, Jiankang

    2014-08-01

    A method was developed to profile major organic acids in Angeleno fruit by high performance liquid chromatography. Organic acids in plum were extracted by water with ultra- sonication at 50°C for 30 min. The extracts were chromatographed on Waters Atlantis T3 C18 column (4.6 mm×250 mm, 5 μm) with 0.01mol/L sulfuric acid and water as mobile phase, and flow rate was 0.5 ml/min. The column temperature was 40C, and chromatography was monitored by a diode array detector at 210 nm. The result showed that malic acid, citric acid, tartaric acid, oxalic acid, pyruvic acid, acetic acid, succinic acid in Angeleno plum, and the malic acid was the major organic acids. The coefficient of determination of the standard calibration curve is R2 > 0.999. The organic acids recovery ranged from 99.11% for Malic acid to 106.70% for Oxalic acid, and CV (n=6) ranged from 0.95% for Malic acid to 6.23% for Oxalic acid, respectively. The method was accurate, sensitive and feasible in analyzing the organic acids in Angeleno plum.

  14. A potential vector of domoic acid: the swimming crab Polybius henslowii Leach (Decapoda-brachyura).

    PubMed

    Costa, Pedro R; Rodrigues, Susana M; Botelho, Maria J; Sampayo, Maria Antónia de M

    2003-08-01

    The swimming crab Polybius henslowii may play an important role in the movement of the amnesic shellfish toxin, domoic acid (DA), through the marine food chain. High DA concentrations have been determined in crab samples harvested along the Portuguese coast during the summer of 2002, reaching a level of 323.1 microg DA/g crab tissue. Toxin distribution in the different crab organs showed levels as high as 571.6 microg DA/g in the visceral tissues. Levels of toxin 4-12 times lower were detected in the remaining tissues. This crab might be a prominent vector of the toxin to higher trophic levels, including fishes, sea birds and even humans. In Portugal P. henslowii is commercialised during the summer in some local markets. DA concentrations were found close to the legal limit of 20 microg/g in samples purchased at Figueira da Foz market. The crabs are boiled prior to reaching the consumers. The cooking process was evaluated. Determination of toxin losses during the cooking process showed a toxin reduction higher than 50%. DA was determined by HPLC-UV and confirmed by spectra acquired with diode-array detector.

  15. Simultaneous determination of potassium guaiacolsulfonate, guaifenesin, diphenhydramine HCl and carbetapentane citrate in syrups by using HPLC-DAD coupled with partial least squares multivariate calibration.

    PubMed

    Dönmez, Ozlem Aksu; Aşçi, Bürge; Bozdoğan, Abdürrezzak; Sungur, Sidika

    2011-02-15

    A simple and rapid analytical procedure was proposed for the determination of chromatographic peaks by means of partial least squares multivariate calibration (PLS) of high-performance liquid chromatography with diode array detection (HPLC-DAD). The method is exemplified with analysis of quaternary mixtures of potassium guaiacolsulfonate (PG), guaifenesin (GU), diphenhydramine HCI (DP) and carbetapentane citrate (CP) in syrup preparations. In this method, the area does not need to be directly measured and predictions are more accurate. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of analytes could be obtained with HPLC-DAD coupled with PLS calibration. This method was tested by analyzing the synthetic mixture of PG, GU, DP and CP. As a comparison method, a classsical HPLC method was used. The proposed methods were applied to syrups samples containing four drugs and the obtained results were statistically compared with each other. Finally, the main advantage of HPLC-PLS method over the classical HPLC method tried to emphasized as the using of simple mobile phase, shorter analysis time and no use of internal standard and gradient elution. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector.

    PubMed

    Faizan, Mohammad; Esatbeyoglu, Tuba; Bayram, Banu; Rimbach, Gerald

    2014-04-01

    Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. © 2014 Institute of Food Technologists®

  17. Analytical determination of flavonoids aimed to analysis of natural samples and active packaging applications.

    PubMed

    Castro-López, María del Mar; López-Vilariño, José Manuel; González-Rodríguez, María Victoria

    2014-05-01

    Several HPLC and UHPLC developed methods were compared to analyse the natural antioxidants catechins and quercetin used in active packaging and functional foods. Photodiode array detector coupled with a fluorescence detector and compared with LTQ-Orbitrap-MS was used. UHPLC was investigated as quick alternative without compromising the separation, analysis time shortened up to 6-fold. The feasibility of the four developed methods was compared. Linearity up to 0.9995, low detection limits (between 0.02 and 0.7 for HPLC-PDA, 2 to 7-fold lower for HPLC- LTQ-Orbitrap-MS and from 0.2 to 2mgL(-)(1) for UHPLC-PDA) and good precision parameters (RSD lower than 0.06%) were obtained. All methods were successfully applied to natural samples. LTQ-Orbitrap-MS allowed to identify other analytes of interest too. Good feasibility of the methods was also concluded from the analysis of catechin and quercetin release from new active packaging materials based on polypropylene added with catechins and green tea. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. SU-F-T-326: Diode Array Transmission Detector Systems Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, D; Dyer, B; Kumaran Nair, C

    2016-06-15

    Purpose: A new transmission detector, Delta4 Discover, developed by Scandidos (Uppsala, Sweden) was evaluated for external photon beam verification and quality assurance. The device is an array of 4040 diodes designed to be mounted on the linac accessory tray to measure photon field shape, position and fluence during patient treatment. Interfractional measurements are compared to a baseline measurement made during delivery quality assurance. The aim of this work is to evaluate the stability of the device and its effect on the shape and magnitude of the treatment beam. Methods: Beam profiles, percent depth dose, and beam attenuation was measured formore » 6, 10, and 15 MV photon beams with and without the device in place for 1×1 and 30×30 cm2 fields. Changes in profile and percent depth dose was quantified to evaluate the need to recommission the treatment beam, or account for the device with a tray factor. The stability of the radiation measurements was evaluated by measuring the deviation of each diode measurement during repeated prostate VMAT treatment delivery. Results: Photon beam profiles changed by < 1.25% in the nonpenumbra regions of the 30×30 cm2 beam. Percent depth dose curves show a 5–7% increased dose at depths < 2.5cm, but agreed within 1% at depths > 2.5cm. This indicates increased skin dose, similar to the use of a physical beam wedge. The device attenuated 6, 10, and 15 MV photon beams by 1.71±0.02%, 1.36±0.03%, and 1.17±0.03%, respectively. The diode array reproduced dosimetric measurements within 0.5% standard deviation for repeated prostate VMAT measurement. Conclusion: The device demonstrated stabile radiation measurements, while not changing the treatment beam shape in a clinically significantly manner. Use of this device can be accounted for with a tray factor, as opposed to recommissioning the treatment beam.« less

  19. Helical tomotherapy quality assurance with ArcCHECK.

    PubMed

    Chapman, David; Barnett, Rob; Yartsev, Slav

    2014-01-01

    To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ~2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  20. Helical tomotherapy quality assurance with ArcCHECK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, David; Barnett, Rob; Yartsev, Slav, E-mail: slav.yartsev@lhsc.on.ca

    2014-07-01

    To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquidmore » and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stelljes, T. S., E-mail: tenzin.s.stelljes@uni-oldenburg.de; Looe, H. K.; Chofor, N.

    Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulatedmore » dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1% over the range from 5 to 1000 MU. The effective point of measurement of the OD1500 for dose measurements in RW3 phantoms was determined to be (8.7 ± 0.2) mm below its front surface. Output factors showed deviations below 1% for field sizes exceeding 4 × 4 cm{sup 2}. The dose per pulse dependence was smaller than 0.4% for doses per pulse from 0.2 to 1 mGy. The energy dependence of the array did not exceed ±0.9%. The parameter σ of the Gaussian lateral dose response function was determined as σ{sub 6MV} = (2.07 ± 0.02) mm for 6 MV and σ{sub 15MV} = (2.09 ± 0.02) mm for 15 MV. An IMRT verification showed passing rates well above 90% for a local 3 mm/3% criterion. Conclusions: The OD1500 array’s dosimetric properties showed the applicability of the array for clinical dosimetry with the possibility to increase the spatial sampling frequency and the coverage of a dose distribution with the sensitive areas of ionization chambers by merging two measurements.« less

  2. Simultaneous Determination of Eight Bioactive Compounds in Dianthus superbus by High-performance Liquid Chromatography

    PubMed Central

    Yun, Bo-Ra; Yang, Hye Jin; Weon, Jin Bae; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2016-01-01

    Background: Dianthus superbus, one of traditional herbal medicine, is widely used to treat urethritis, carbuncles and carcinoma. Objective: A simultaneous determination method was established for controlling the quality of D. superbus using the eight compounds, (E)-methyl-4-hydroxy-4-(8a-methyl-3-oxodecahydronaphthalen-4a-yl) (1), diosmetin-7-O(2'',6''-di-O-α-L-rhamnopyranosyl)-β-D-glucopyranoside (2), vanillic acid (3), 4-hydroxyphenyl acetic acid (4), 4-methoxyphenyl acetic acid (5), (E)-4-methoxycinnamic acid (6), 3-methoxy-4-hydroxyphenylethanol (7), and methyl hydroferulate (8) isolated from D. superbus. Materials and Methods: This analysis method was developed using high performance liquid chromatography coupled with diode array detector with a Shishedo C18 column at a column temperature of 3°C. The mobile phase was composed of 0.1% trifluoroacetic acid in water and acetonitrile. The flow rate was 1 ml/min and detection wavelength was set at 205 nm and 280 nm. Validation was performed in order to demonstrate selectivity, accuracy and precision of the method. Results: The calibration curves showed good linearity (R2 > 0.99). The limits of detection and limits of quantification were within the ranges 0.0159–0.6205 μg/ml and 0.3210–1.8802 μg/ml, respectively. Moreover, the relative standard deviations of intra- and inter-day precision were both <2.98%. The overall recoveries were in the range of 96.23–109.87%. Quantitative analysis of eight compounds in 12 D. superbus samples (D-1–D-12) from various regions were analyzed and compared by developed method. Conclusion: As a result, this established method was accurate and sensitive for the quality evaluation of eight compounds isolated from D. superbus and may provide a new basis for quality control of D. superbus. SUMMARY A simultaneous determination method of eight compounds in Dianthus superbus was established by high performance liquid chromatography-diode array detectorDeveloped analysis method is validated with linearity, precious and accuracyThe newly established method was successfully evaluated contents of eight compounds in 12 D. superbus samples (D.1.D.12) from various regions and compared. Abbreviations used: HPLC: High performance liquid chromatography, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation. PMID:27279718

  3. Simultaneous Determination of Eight Bioactive Compounds in Dianthus superbus by High-performance Liquid Chromatography.

    PubMed

    Yun, Bo-Ra; Yang, Hye Jin; Weon, Jin Bae; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2016-05-01

    Dianthus superbus, one of traditional herbal medicine, is widely used to treat urethritis, carbuncles and carcinoma. A simultaneous determination method was established for controlling the quality of D. superbus using the eight compounds, (E)-methyl-4-hydroxy-4-(8a-methyl-3-oxodecahydronaphthalen-4a-yl) (1), diosmetin-7-O(2'',6''-di-O-α-L-rhamnopyranosyl)-β-D-glucopyranoside (2), vanillic acid (3), 4-hydroxyphenyl acetic acid (4), 4-methoxyphenyl acetic acid (5), (E)-4-methoxycinnamic acid (6), 3-methoxy-4-hydroxyphenylethanol (7), and methyl hydroferulate (8) isolated from D. superbus. This analysis method was developed using high performance liquid chromatography coupled with diode array detector with a Shishedo C18 column at a column temperature of 3°C. The mobile phase was composed of 0.1% trifluoroacetic acid in water and acetonitrile. The flow rate was 1 ml/min and detection wavelength was set at 205 nm and 280 nm. Validation was performed in order to demonstrate selectivity, accuracy and precision of the method. The calibration curves showed good linearity (R (2) > 0.99). The limits of detection and limits of quantification were within the ranges 0.0159-0.6205 μg/ml and 0.3210-1.8802 μg/ml, respectively. Moreover, the relative standard deviations of intra- and inter-day precision were both <2.98%. The overall recoveries were in the range of 96.23-109.87%. Quantitative analysis of eight compounds in 12 D. superbus samples (D-1-D-12) from various regions were analyzed and compared by developed method. As a result, this established method was accurate and sensitive for the quality evaluation of eight compounds isolated from D. superbus and may provide a new basis for quality control of D. superbus. A simultaneous determination method of eight compounds in Dianthus superbus was established by high performance liquid chromatography-diode array detectorDeveloped analysis method is validated with linearity, precious and accuracyThe newly established method was successfully evaluated contents of eight compounds in 12 D. superbus samples (D.1.D.12) from various regions and compared. Abbreviations used: HPLC: High performance liquid chromatography, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation.

  4. Removal of famoxadone, fluquinconazole and trifloxystrobin residues in red wines: effects of clarification and filtration processes.

    PubMed

    Oliva, Jose; Payá, Paula; Cámara, Miguel Angel; Barba, Alberto

    2007-01-01

    The effects of six clarification agents [egg albumin, blood albumin, bentonite + gelatine, charcoal, polyvinylpolypyrrolidine (PVPP) and silica gel] on the removal of residues of three fungicides (famoxadone, fluquinconazole and trifloxystrobin) applied directly to a racked red wine, elaborated from Monastrell variety grapes from the D.O. Region of Jumilla (Murcia, Spain) were studied. The clarified wines were filtered with 0.45 microm nylon filters to determine the influence of this winemaking process in the disappearance of fungicide residues. Analytical determination of fluquinconazole and trifloxystrobin was performed by gas chromatography with electron captor detector (ECD), while that of famoxadone using an HPLC equipped with a diode array detector (DAD). Generally, trifloxystrobin is the fungicide that is the lowest persistent one in wines, except in the egg albumin study whereas, the most persistent one is fluquinconazole. The elimination depends on the nature of the active ingredient, though the water stability in the presence of light within it has more influence than the solubility and polarity of the product itself. The most effective clarifying agents were the charcoal and PVPP. The silica gel and bentonite plus gelatine were not enough to reduce considerably the residual contents in the wine clarified with them. In general terms, filtration is not an effective step in the elimination of wine residues. The greatest removal after filtration is obtained in wines clarified with egg albumine and bentonite plus gelatine, and the lowest in those clarified with PVPP.

  5. Identification and quantification of carotenoids, by HPLC-PDA-MS/MS, from Amazonian fruits.

    PubMed

    de Rosso, Veridiana V; Mercadante, Adriana Z

    2007-06-27

    The major and minor carotenoids from six fruits, buriti (Mauritia vinifera), mamey (Mammea americana), marimari (Geoffrola striata), peach palm (Bactrys gasipaes), physalis (Physalis angulata), and tucuma (Astrocaryum aculeatum), all native to the Amazonia region, were determined by high-performance liquid chromatography-photodiode array detector-mass spectrometry detector (HPLC-PDA-MS/MS), fulfilling the recommended criteria for identification. A total of 60 different carotenoids were separated on a C30 column, all-trans-beta-carotene being the major carotenoid found in all fruits. The presence of apo-10'-beta-carotenol, found in mamey, was not previously reported in foods. In addition, this is the first time that the identification of beta-zeacarotene in natural sources is supported by MS data. The total carotenoid content ranged from 38 microg/g in marimari to 514 microg/g in buriti. All fruits analyzed can be considered good sources of provitamin A, especially buriti, with 7280 RE/100 g.

  6. Terahertz detectors and focal plane arrays

    NASA Astrophysics Data System (ADS)

    Rogalski, A.; Sizov, F.

    2011-09-01

    Terahertz (THz) technology is one of emerging technologies that will change our life. A lot of attractive applications in security, medicine, biology, astronomy, and non-destructive materials testing have been demonstrated already. However, the realization of THz emitters and receivers is a challenge because the frequencies are too high for conventional electronics and the photon energies are too small for classical optics. As a result, THz radiation is resistant to the techniques commonly employed in these well established neighbouring bands. In the paper, issues associated with the development and exploitation of THz radiation detectors and focal plane arrays are discussed. Historical impressive progress in THz detector sensitivity in a period of more than half century is analyzed. More attention is put on the basic physical phenomena and the recent progress in both direct and heterodyne detectors. After short description of general classification of THz detectors, more details concern Schottky barrier diodes, pair braking detectors, hot electron mixers and field-effect transistor detectors, where links between THz devices and modern technologies such as micromachining are underlined. Also, the operational conditions of THz detectors and their upper performance limits are reviewed. Finally, recent advances in novel nanoelectronic materials and technologies are described. It is expected that applications of nanoscale materials and devices will open the door for further performance improvement in THz detectors.

  7. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    NASA Astrophysics Data System (ADS)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  8. Proposed Use of Zero Bias Diode Arrays as Thermal Electric Noise Rectifiers and Non-Thermal Energy Harvesters

    NASA Astrophysics Data System (ADS)

    Valone, Thomas F.

    2009-03-01

    The well known built-in voltage potential for some select semiconductor p-n junctions and various rectifying devices is proposed to be favorable for generating DC electricity at "zero bias" (with no DC bias voltage applied) in the presence of Johnson noise or 1/f noise which originates from the quantum vacuum (Koch et al., 1982). The 1982 Koch discovery that certain solid state devices exhibit measurable quantum noise has also recently been labeled a finding of dark energy in the lab (Beck and Mackey, 2004). Tunnel diodes are a class of rectifiers that are qualified and some have been credited with conducting only because of quantum fluctuations. Microwave diodes are also good choices since many are designed for zero bias operation. A completely passive, unamplified zero bias diode converter/detector for millimeter (GHz) waves was developed by HRL Labs in 2006 under a DARPA contract, utilizing a Sb-based "backward tunnel diode" (BTD). It is reported to be a "true zero-bias diode." It was developed for a "field radiometer" to "collect thermally radiated power" (in other words, 'night vision'). The diode array mounting allows a feed from horn antenna, which functions as a passive concentrating amplifier. An important clue is the "noise equivalent power" of 1.1 pW per root hertz and the "noise equivalent temperature difference" of 10° K, which indicate sensitivity to Johnson noise (Lynch, et al., 2006). There also have been other inventions such as "single electron transistors" that also have "the highest signal to noise ratio" near zero bias. Furthermore, "ultrasensitive" devices that convert radio frequencies have been invented that operate at outer space temperatures (3 degrees above zero point: 3° K). These devices are tiny nanotech devices which are suitable for assembly in parallel circuits (such as a 2-D array) to possibly produce zero point energy direct current electricity with significant power density (Brenning et al., 2006). Photovoltaic p-n junction cells are also considered for possible higher frequency ZPE transduction. Diode arrays of self-assembled molecular rectifiers or preferably, nano-sized cylindrical diodes are shown to reasonably provide for rectification of electron fluctuations from thermal and non-thermal ZPE sources to create an alternative energy DC electrical generator in the picowatt per diode range.

  9. Identification of phenolic compounds from the leaf part of Teucrium pseudo-Scorodonia Desf. collected from Algeria.

    PubMed

    Belarbi, Karima; Atik-Bekkara, Fawzia; El Haci, Imad Abdelhamid; Bensaid, Ilhem; Bekhechi, Chahrazed

    2018-02-01

    In the present paper,we reported for the first time, the identification of the phenolic compounds in butanolic fraction obtained from the leaf part of Teucrium pseudo-Scorodonia Desf. collected from Algeria using RP-HPLC-PDA (Reversed Phase High Performance Liquid Chromatography/Photo Diode Array) technique. Several standards were used for this purpose. The analysis led to the identification of six phenolic acids (ferulic, sinapic, rosmarinic, syringique, caffeic, p-coumaric acids) and one flavonoid (rutin), the last one, has interesting pharmacological properties.

  10. Advanced Instrumentation for Aero Engine Components: Conference Proceedings of the Propulsion and Energetics Panel Symposium (67th) Held in Philadelphia, Pennsylvania on 19-23 May 1986.

    DTIC Science & Technology

    1986-11-01

    optical wave-mixing am., interact via the third order non linear susceptibility of the medium to produce a coherent laser-like signal beam at the higher...is the third order non- linear susceptibility of the medium and determines the shape of the CARS spectrum. It is the sum of a resonant contribution and...simultaneously using an appropriate spectrograph/optical multichannel detector; intensified linear diode array detectors are now used in most systems. The two

  11. High intensity click statistics from a 10 × 10 avalanche photodiode array

    NASA Astrophysics Data System (ADS)

    Kröger, Johannes; Ahrens, Thomas; Sperling, Jan; Vogel, Werner; Stolz, Heinrich; Hage, Boris

    2017-11-01

    Photon-number measurements are a fundamental technique for the discrimination and characterization of quantum states of light. Beyond the abilities of state-of-the-art devices, we present measurements with an array of 100 avalanche photodiodes exposed to photon-numbers ranging from well below to significantly above one photon per diode. Despite each single diode only discriminating between zero and non-zero photon-numbers we were able to extract a second order moment, which acts as a nonclassicality indicator. We demonstrate a vast enhancement of the applicable intensity range by two orders of magnitude relative to the standard application of such devices. It turns out that the probabilistic mapping of arbitrary photon-numbers on a finite number of registered clicks is not per se a disadvantage compared with true photon counters. Such detector arrays can bridge the gap between single-photon and linear detection, by investigation of the click statistics, without the necessity of photon statistics reconstruction.

  12. Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification.

    PubMed

    Toltz, Allison; Hoesl, Michaela; Schuemann, Jan; Seuntjens, Jan; Lu, Hsiao-Ming; Paganetti, Harald

    2017-11-01

    Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish a beam-specific response to WEPL fit for the selected 'scout' beam (a 1 cm overshoot of the predicted detector depth with a dose of 4 cGy) in water-equivalent plastic. This necessitates a separate set of measurements for every 'scout' beam that may be appropriate to the clinical case. The current study demonstrates the use of Monte Carlo simulations for calibration of the time-resolved diode dosimetry technique. Measurements for three 'scout' beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). The 'scout' beams were then applied in the simulation environment to simulated water-equivalent plastic, a CT of water-equivalent plastic, and a patient CT data set to assess uncertainty. Simulated detector response in water-equivalent plastic was validated against measurements for 'scout' spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) to within 3.4 mm for all beams, and to within 1 mm in the region where the detector is expected to lie. Feasibility has been shown for performing the calibration of the detector response for three 'scout' beams through simulation for the time-resolved diode dosimetry technique in passive scattered proton delivery. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  13. Phytoestrogen Concentrations in Human Urine as Biomarkers for Dietary Phytoestrogen Intake in Mexican Women

    PubMed Central

    Chávez-Suárez, Karina M.; Ortega-Vélez, María I.; Valenzuela-Quintanar, Ana I.; Galván-Portillo, Marcia; López-Carrillo, Lizbeth; Esparza-Romero, Julián; Saucedo-Tamayo, María S.; Robles-Burgueño, María R.; Gutiérrez-Coronado, María L.; Campa-Siqueiros, Melissa M.; Grajeda-Cota, Patricia; Caire-Juvera, Graciela

    2017-01-01

    There has been substantial interest in phytoestrogens, because of their potential effect in reducing cancer and heart disease risk. Measuring concentrations of phytoestrogens in urine is an alternative method for conducting epidemiological studies. Our objective was to evaluate the urinary excretion of phytoestrogens as biomarkers for dietary phytoestrogen intake in Mexican women. Participants were 100 healthy women from 25 to 80 years of age. A food frequency questionnaire (FFQ) and a 24 h recall were used to estimate habitual and recent intakes of isoflavones, lignans, flavonols, coumestrol, resveratrol, naringenin, and luteolin. Urinary concentrations were measured by liquid chromatography (HPLC) coupled to mass spectrometry (MS) using the electrospray ionization interface (ESI) and diode array detector (DAD) (HPLC-DAD-ESI-MS). Spearman correlation coefficients were used to evaluate associations between dietary intake and urine concentrations. The habitual consumption (FFQ) of total phytoestrogens was 37.56 mg/day. In urine, the higher compounds were naringenin (60.1 µg/L) and enterolactone (41.7 µg/L). Recent intakes (24 h recall) of isoflavones (r = 0.460, p < 0.001), lignans (r = 0.550, p < 0.0001), flavonoids (r = 0.240, p < 0.05), and total phytoestrogens (r = 0.410, p < 0.001) were correlated to their urinary levels. Total phytoestrogen intakes estimated by the FFQ showed higher correlations to urinary levels (r = 0.730, p < 0.0001). Urinary phytoestrogens may be useful as biomarkers of phytoestrogen intake, and as a tool for evaluating the relationship of intake and disease risk in Mexican women. PMID:28961176

  14. Development of a liquid chromatography assay for the determination of opicapone and BIA 9-1079 in rat matrices.

    PubMed

    Gonçalves, Daniela; Alves, Gilberto; Fortuna, Ana; Soares-da-Silva, Patrício; Falcão, Amílcar

    2016-03-01

    Opicapone is a novel potent, reversible and purely peripheral third generation catechol-O-methyltransferase inhibitor, currently under clinical trials as an adjunct to levodopa therapy for Parkinson's disease. To support additional nonclinical pharmacokinetic studies, a novel high-performance liquid chromatographic method coupled to a diode array detector (HPLC-DAD) to quantify opicapone and its active metabolite (BIA 9-1079) in rat plasma and tissues (liver and kidney) is herein reported. The analytes were extracted from rat samples through a deproteinization followed by liquid-liquid extraction. Chromatographic separation was achieved in less than 10 min on a reversed-phase C18 column, applying a gradient elution program with 0.05 M monosodium phosphate solution (pH 2.45 ± 0.05) and acetonitrile. Calibration curves were linear (r(2)  ≥ 0.994) within the ranges of 0.04-6.0 µg/mL for both analytes in plasma, 0.04-4.0 µg/mL for opicapone in liver and kidney homogenates, and 0.07-4.0 µg/mL and 0.06-4.0 µg/mL for BIA 9-1079 in liver and kidney homogenates, respectively. The overall intra- and inter-day accuracy ranged from -12.68% to 7.70% and the imprecision values did not exceed 11.95%. This new HPLC-DAD assay was also successfully applied to quantify opicapone and BIA 9-1079 in a preliminary pharmacokinetic study. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Lipid Nanocarriers for Oral Delivery of Serenoa repens CO2 Extract: A Study of Microemulsion and Self-Microemulsifying Drug Delivery Systems.

    PubMed

    Guccione, Clizia; Bergonzi, Maria Camilla; Awada, Khaled M; Piazzini, Vieri; Bilia, Anna Rita

    2018-07-01

    The aim of this study was the development and characterization of lipid nanocarriers using food grade components for oral delivery of Serenoa repens CO 2 extract, namely microemulsions (MEs) and self-microemulsifying drug delivery systems (SMEDDSs) to improve the oral absorption. A commercial blend (CB) containing 320 of S. repens CO 2 extract plus the aqueous soluble extracts of nettle root and pineapple stem was formulated in two MEs and two SMEDDSs. The optimized ME loaded with the CB (CBM2) had a very low content of water (only 17.3%). The drug delivery systems were characterized by dynamic light scattering, transmission electron microscopy, and high-performance liquid chromatography (HPLC) with a diode-array detector analyses in order to evaluate the size, the homogeneity, the morphology, and the encapsulation efficiency. β -carotene was selected as marker for the quantitative HPLC analysis. Additionally, physical and chemical stabilities were acceptable during 3 wk at 4 °C. Stability of these nanocarriers in simulated stomach and intestinal conditions was proved. Finally, the improvement of oral absorption of S. repens was studied in vitro using parallel artificial membrane permeability assay. An enhancement of oral permeation was found in both CBM2 and CBS2 nanoformulations comparing with the CB and S. repens CO 2 extract. The best performance was obtained by the CBM2 nanoformulation (~ 17%) predicting a 30 - 70% passive oral human absorption in vivo . Georg Thieme Verlag KG Stuttgart · New York.

  16. Determination of the Marker Diarylheptanoid Phytoestrogens in Curcuma comosa Rhizomes and Selected Herbal Medicinal Products by HPLC-DAD.

    PubMed

    Yingngam, Bancha; Brantner, Adelheid; Jinarat, Damrongsak; Kaewamatawong, Rawiwun; Rungseevijitprapa, Wandee; Suksamrarn, Apichart; Piyachaturawat, Pawinee; Chokchaisiri, Ratchanaporn

    2018-01-01

    A method for quantification of diarylheptanoids in Curcuma comosa rhizomes and selected pharmaceutical preparations was established by using HPLC-diode array detector (DAD). The chromatographic separation of three diarylheptanoids [(3S)-1-(3,4-dihydroxy-phenyl)-7-phenyl-(6E)-6-hepten-3-ol (1), (3R)-1,7-diphenyl-(4E,6E)-4,6-heptadien-3-ol (2), and (3S)-1,7-diphenyl-(6E)-6-hepten-3-ol (3)] was performed on a Luna C 18 analytical column using gradient elution with 0.5% acetic acid in water and acetonitrile with a flow rate of 1 mL/min and a column temperature of 35°C. The calibration curves for the analytes showed good linearity (R 2 >0.999), high precision (relative standard deviation (RSD) <2%) and acceptable recovery (98.35-103.90%, RSD <2%). The limit of detection (LOD) and limit of quantification (LOQ) were 0.06-0.22 and 0.18-0.69 µg/mL, respectively. The results of all validated parameters were within the limits according to the International Conference on Harmonization (ICH) Guidelines. The established method was successfully applied for qualitative and quantitative determination of the three constituents in different samples of C. comosa and some commercial products in capsules. The simplicity, rapidity, and reliability of the method could be useful for the fingerprint analysis and standardization of diarylheptanoids, which are responsible for the estrogenic activity in raw materials and herbal medicinal products of C. comosa.

  17. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    PubMed

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and quantification of 17 free amino acids in Orthosiphon stamineus (OS) Benth extractsOS extracts were found to be rich in free amino acid contentL-aspartic acid was the major free amino acid in OS water extract while, in OS ethanol, methanol, 50% ethanol and 50% methanol extracts, L-glutamic acid was the major free amino acidL-serine was the minor free amino acid in OS water, ethanol and methanol extracts while, in OS 50% ethanol and 50% methanol extracts, L-threonine had the lowest concentration compared to other amino acid components. Abbreviations used: HPLC-DAD: High-Performance Liquid Chromatography with Diode-Array Detection, OS: Orthosiphon stamineus , OS-W: Orthosiphon stamineus water extract, OS-E: Orthosiphon stamineus ethanol extract, OS-M: Orthosiphon stamineus methanol extract, OS-EW: Orthosiphon stamineus 50% ethanol extract, OS-MW: Orthosiphon stamineus 50% methanol extract, OPA: O-phthaladehyde , SPE: Solid Phase Extraction, UV: Ultraviolet, LOD: Limit of Detection, LOQ: Limit of Quantification, RSD: Relative Standard Deviation.

  18. Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    PubMed

    Catuzzo, P; Zenone, F; Aimonetto, S; Peruzzo, A; Casanova Borca, V; Pasquino, M; Franco, P; La Porta, M R; Ricardi, U; Tofani, S

    2012-07-01

    To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of gafchromic films, was compared with an alternative approach based on the use of two commercially available diode arrays, MapCHECK2(TM) and ArcCHECK(TM). The TomoDirect(TM) plans of twenty patients with a primary unilateral breast cancer were applied to a CT scan of the Cheese Phantom and a MVCT dataset of the diode arrays. Then measurements of 2D dose distribution were performed and compared with the calculated ones using the gamma analysis method with different sets of DTA and DD criteria (3%-3 mm, 3%-2 mm). The sensitivity of the diode arrays to detect delivery and setup errors was also investigated. The measured dose distributions showed excellent agreement with the TPS calculations for each detector, with averaged fractions of passed Γ values greater than 95%. The percentage of points satisfying the constraint Γ < 1 was significantly higher for MapCHECK2(TM) than for ArcCHECK(TM) and gafchromic films using both the 3%-3 mm and 3%-2 mm gamma criteria. Both the diode arrays show a good sensitivity to delivery and setup errors using a 3%-2 mm gamma criteria. MapCHECK2™ and ArcCHECK(TM) may fulfill the demands of an adequate system for TomoDirect(TM) patient-specific QA.

  19. Simultaneous determination of flavonoids, isochlorogenic acids and triterpenoids in Ilex hainanensis Using high performance liquid chromatography coupled with diode array and evaporative light scattering detection.

    PubMed

    Peng, Bo; Qiao, Chun-Feng; Zhao, Jing; Huang, Wei-Hua; Hu, De-Jun; Liu, Hua-Gang; Li, Shao-Ping

    2013-03-04

    A high performance liquid chromatography coupled with diode array and evaporative light scattering detection (HPLC-DAD-ELSD) method for simultaneous determination of eight major bioactive compounds including two flavonoids (rutin and eriodictyol-7-O-β-D-glucopyranoside), two isochlorogenic acids (isochlorogenic acid A and isochlorogenic acid C) and four triterpenoids (ilexhainanoside D, ilexsaponin A1, ilexgenin A and ursolic acid) in Ilex hainanensis has been developed for the first time. The 283 nm wavelength was chosen for determination of two flavonoids and two isochlorogenic acids. ELSD was applied to determine four triterpenoids. The analysis was performed on an Agilent Zorbax SB-C18 column (250 × 4.6 mm i.d., 5 µm) with gradient elution of 0.2% formic acid in water and acetonitrile. The method was validated for linearity, limit of detection, limit of quantification, precision, repeatability and accuracy. The proposed method has been successfully applied for simultaneous quantification of the analytes in four samples of Ilex hainanensis, which is helpful for quality control of this plant.

  20. Rapid separation and identification of phenolics in crude red grape skin extracts by high performance liquid chromatography coupled to diode array detection and tandem mass spectrometry.

    PubMed

    Ji, Mei; Li, Chen; Li, Qiang

    2015-10-02

    A rapid and efficient method was established for the simultaneous determination of structures and configurations for 45 phenolics isolated from crude red grape skin extracts without extensive sample preparation. Separation and compound assignments were achieved using high performance liquid chromatography coupled to diode array detection and tandem mass spectrometry (HPLC-DAD-MS(2)). A Poroshell 120 EC-C18 (100mm×3.0mm, 2.7μm) column was employed to separate the phenolics, which were eluted using a gradient of acetonitrile and water acidified with 0.2% formic acid. Phenolics were identified by comparison of their UV-vis spectra, mass spectra and MS(2) data with those in the literature. Using this procedure, five compounds were detected for the first time in Vitis amurensis. Good separation of most phenolics was achieved in 26min. The methods described here can be used for the characterization of phenolics in a variety of grapes and grape products. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Latest developments of 10μm pitch HgCdTe diode array from the legacy to the extrinsic technology

    NASA Astrophysics Data System (ADS)

    Péré-Laperne, Nicolas; Berthoz, Jocelyn; Taalat, Rachid; Rubaldo, Laurent; Kerlain, Alexandre; Carrère, Emmanuel; Dargent, Loïc.

    2016-05-01

    Sofradir recently presented Daphnis, its latest 10 μm pitch product family. Both Daphnis XGA and HD720 are 10μm pitch mid-wave infrared focal plane array. Development of small pixel pitch is opening the way to very compact products with a high spatial resolution. This new product is taking part in the HOT technology competition allowing reductions in size, weight and power of the overall package. This paper presents the recent developments achieved at Sofradir to make the 10μm pitch HgCdTe focal plane array based on the legacy technology. Electrical and electro-optical characterizations are presented to define the appropriate design of 10μm pitch diode array. The technological tradeoffs are explained to lower the dark current, to keep high quantum efficiency with a high operability above 110K, F/4. Also, Sofradir recently achieved outstanding Modulation Transfer Function (MTF) demonstration at this pixel pitch, which clearly demonstrates the benefit to users of adopting 10μm pixel pitch focal plane array based detectors. Furthermore, the HgCdTe technology has demonstrated an increase of the operating temperature, plus 40K, moving from the legacy to the P-on-n one at a 15μm pitch in mid-wave band. The first realizations using the extrinsic P-on-n technology and the characterizations of diodes with a 10μm pitch neighborhood will be presented in both mid-wave and long-wave bands.

  2. Simultaneous determination of 12 chemical constituents in the traditional Chinese Medicinal Prescription Xiao-Yao-San-Jia-Wei by HPLC coupled with photodiode array detection.

    PubMed

    Zhang, Hongmin; Chen, Shiwei; Qin, Feng; Huang, Xi; Ren, Ping; Gu, Xinqi

    2008-12-15

    An HPLC-photodiode array (PDA) detection method was established for the simultaneous determination of 12 components in Xiao-Yao-San-Jia-Wei (XYSJW): geniposide, puerarin, paeoniflorin, ferulic acid, liquiritin, hesperidin, naringin, paeonol, daidzein, glycyrrhizic acid, honokiol, and magnolol. These were separated in less than 70 min using a Waters Symmetry Shield RP 18 column with gradient elution using (A) acetonitrile, (B) water, and (C) acetic acid at a flow rate of 1 ml/min, and with a PDA detector. All calibration curves showed good linear regression (r(2)>0.9992) within the test ranges. The method was validated for specificity, accuracy, precision, and limits of detection. The proposed method enables in a single run the simultaneous identification and determination for quality control of 12 multi-structural components of XYSJW forming the basis of its therapeutic effect.

  3. Power monitoring in space nuclear reactors using silicon carbide radiation detectors

    NASA Technical Reports Server (NTRS)

    Ruddy, Frank H.; Patel, Jagdish U.; Williams, John G.

    2005-01-01

    Space reactor power monitors based on silicon carbide (SiC) semiconductor neutron detectors are proposed. Detection of fast leakage neutrons using SiC detectors in ex-core locations could be used to determine reactor power: Neutron fluxes, gamma-ray dose rates and ambient temperatures have been calculated as a function of distance from the reactor core, and the feasibility of power monitoring with SiC detectors has been evaluated at several ex-core locations. Arrays of SiC diodes can be configured to provide the required count rates to monitor reactor power from startup to full power Due to their resistance to temperature and the effects of neutron and gamma-ray exposure, SiC detectors can be expected to provide power monitoring information for the fill mission of a space reactor.

  4. [Identification of impurity peaks in the HPLC chromatogram by LC-MS and two-dimensional chromatographic correlation spectroscopy].

    PubMed

    Chen, Zhen-Zhen; Zhang, Dou-Sheng; Wang, Nan; Feng, Fang; Hu, Chang-Qin

    2012-04-01

    A novel qualitative analytical method by using two-dimensional chromatographic correlation spectroscopy techniques for recognizing impurity peaks of HPLC methods of quality control and LC-MS chromatographic system was established. The structures of major degradation products of ceftizoxime and cefdinir were identified by LC-MS and MassWorks application; the standard chromatographic and spectral data of the degradation impurities were obtained by high-performance liquid chromatography with diode array detection. The impurity peaks of two-dimensional chromatography were matched by comparison of spectra and calculating correlation coefficients. Peaks in chromatography can be identified accurately and rapidly in different chromatographic systems such as column and mobile phase changed. The method provides a new way and thought to identify the peaks in quality control of impurities without reference impurity substances.

  5. Screening of anti-HIV-1 inophyllums by HPLC-DAD of Calophyllum inophyllum leaf extracts from French Polynesia Islands.

    PubMed

    Laure, Frédéric; Raharivelomanana, Phila; Butaud, Jean-François; Bianchini, Jean-Pierre; Gaydou, Emile M

    2008-08-22

    Various pyranocoumarins, calophyllolide, inophyllums B, C, G(1), G(2) and P, from Calophyllum inophyllum (Clusiaceae) leaves of French Polynesia (Austral, Marquesas, Society and Tuamotu archipelagos) have been determined in 136 leaf extracts using a high pressure liquid chromatography-UV-diode array detection (HPLC-UV-DAD) technique. Results show a wide range in chemical composition within trees growing on eighteen islands. The use of multivariate statistical analyses (PCA) shows geographical distribution of inophyllums and indicate those rich in HIV-1 active (+)-inophyllums. Inophyllum B and P contents (0.0-39.0 and 0.0-21.8 mg kg(-1), respectively) confirm the chemodiversity of this species within the large area of French Polynesia. The study suggests the presence of interesting chemotypes which could be used as plant source for anti-HIV-1 drugs.

  6. High-performance liquid chromatography ultraviolet-photodiode array detection method for aflatoxin B1 in cattle feed supplements

    PubMed Central

    Mochamad, Lazuardi; Hermanto, Bambang

    2017-01-01

    Aim: The objective of the current study is to determine the concentration of aflatoxin B1 using high-performance liquid chromatography (HPLC) with a photodiode array (PDA) detector. Materials and Methods: Aflatoxin B1 certified reference grade from Trilogy Analytical Laboratory dissolved acetonitrile (ACN) at 10 µg/mL was using standard assessment. HPLC instruments such as ultraviolet-PDA detector used a Shimadzu LC-6AD pump with DGU-20A5 degasser, communication module-20A, and PDA detector SPD-M20A with FRC-10A fraction collector. The HPLC was set isocratic method at 354 nm with a reverse-phase ODS C18 column (LiChrospher® 100 RP-18; diameter, 5 µm) under a 20°C controlled column chamber. Rheodyne® sample loops were performed in 20 µL capacities. The mobile phase was performed at fraction 63:26:11 H2O: methanol:ACN at pH 6.8. A total of 1 kg of feed contained 10% bread crumbs and 30% concentrated, 40% forage, and 20% soybean dregs were using commercials samples. Samples were extracted by ACN and separated with solid phase extraction ODS 1 mL than elution with mobile phase to collect at drying samples performed. The samples were ready to use after added 1 mL mobile phase than injected into the system of HPLC. Results: We found that the retention time of aflatoxin B1 was approximately 10.858 min. Linearity of 0.01-0.08 µg/mL aflatoxin B1 dissolved in mobile phase was obtained at R2=0.9. These results demonstrate that these methods can be used to analyze aflatoxin B1 and gain 89-99% recovery. The limit of detection of this assay was obtained at 3.5 × 10−6 µg/mL. Conclusion: This method was easy to apply and suitable to analyzing at small concentrations of aflatoxin B1 in formulated product of feed cattle. PMID:28919686

  7. Characterization and simultaneous quantification of biological aporphine alkaloids in Litsea cubeba by HPLC with hybrid ion trap time-of-flight mass spectrometry and HPLC with diode array detection.

    PubMed

    Zhang, Shuiying; Zhang, Qian; Guo, Qiang; Zhao, Yunfang; Gao, Xiaoli; Chai, Xingyun; Tu, Pengfei

    2015-08-01

    The root and rhizome of Litsea cubeba (Lour) Pers., named 'Dou-chi-jiang' in Chinese, has been traditionally used for treatment of cardiovascular and cerebrovascular diseases, rheumatic arthralgia, and other diseases in China. Aporphine alkaloids are its characteristic ingredients and responsible for its bioactivities, especially anti-inflammatory and analgesic effects. A sensitive and reliable high-performance liquid chromatography with diode array detection-tandem mass spectrometry method was developed for characterization and simultaneous determination of biological aporphine alkaloids in 'Dou-chi-jiang'. The optimized chromatographic conditions were performed on an Eclipse XDB C18 column with a gradient of acetonitrile/water containing 0.1% formic acid as the mass spectrometry mobile phase and acetonitrile/water containing 0.2% diethylamine (pH 3.10, adjusted by acetic acid) as the liquid chromatography mobile phase. The fragmentation pathways by loss of CO, ·CH3 , ·NH3 , and ·NH2 CH3 were detected as characteristic for aporphine alkaloids. Based on these characteristics, total 12 analogues were identified. The quantification method was validated in terms of linearity, precision, and accuracy for six major aporphine alkaloids, which was successfully applied for simultaneous determination in ten batches of samples. The established method is simple, rapid, and specific for characterization and quantitation of aporphine alkaloids in 'Dou-chi-jiang' and other traditional Chinese medicines rich in this kind of ingredient. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    PubMed

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development and validation of a rapid stability indicating HPLC-method using monolithic stationary phase and two spectrophotometric methods for determination of antihistaminic acrivastine in capsules

    NASA Astrophysics Data System (ADS)

    Gouda, Ayman A.; Hashem, Hisham; Jira, Thomas

    2014-09-01

    Simple, rapid and accurate high performance liquid chromatographic (HPLC) and spectrophotometric methods are described for determination of antihistaminic acrivastine in capsules. The first method (method A) is based on accurate, sensitive and stability indicating chromatographic separation method. Chromolith® Performance RP-18e column, a relatively new packing material consisting of monolithic rods of highly porous silica, was used as stationary phase applying isocratic binary mobile phase of ACN and 25 mM NaH2PO4 pH 4.0 in the ratio of 22.5:77.5 at flow rate of 5.0 mL/min and 40 °C. A diode array detector was used at 254 nm for detection. The elution time of acrivastine was found to be 2.080 ± 0.032. The second and third methods (methods B and C) are based on the oxidation of acrivastine with excess N-bromosuccinimide (NBS) and determination of the unconsumed NBS with, metol-sulphanilic acid (λmax: 520 nm) or amaranth dye (λmax: 530 nm). The reacted oxidant corresponds to the drug content. Beer’s law is obeyed over the concentration range 1.563-50, 2.0-20 and 1.0-10 μg mL-1 for methods A, B and C, respectively. The limits of detection and quantitation were 0.40, 0.292 and 0.113 μg mL-1 and 0.782, 0.973 and 0.376 μg mL-1 for methods A, B and C, respectively. The HPLC method was validated for system suitability, linearity, precision, limits of detection and quantitation, specificity, stability and robustness. Stability tests were done through exposure of the analyte solution for four different stress conditions and the results indicate no interference of degradants with HPLC-method. The proposed methods was favorably applied for determination of acrivastine in capsules formulation. Statistical comparison of the obtained results from the analysis of the studied drug to those of the reported method using t- and F-tests showed no significant difference between them.

  10. Determination of four major saponins in the seeds of Aesculus chinensis Bunge using accelerated solvent extraction followed by high-performance liquid chromatography and electrospray-time of flight mass spectrometry.

    PubMed

    Chen, Junhui; Li, Wenlong; Yang, Baijuan; Guo, Xiuchun; Lee, Frank Sen-Chun; Wang, Xiaoru

    2007-07-23

    A new method based on accelerated solvent extraction (ASE) followed by a reliable high-performance liquid chromatography-diode array detector (HPLC-DAD) and positive ion electrospray-time of flight mass spectrometry (ESI-TOF/MS) analysis has been developed for the characterization and quantification of four major saponins in extracts of the seeds of Aesculus chinensis Bunge (semen aesculi). The saponins escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted from seeds of A. chinesis Bunge via ASE, and the operational parameters of ASE were optimized, such as extraction solvent, extraction temperature, static extraction time and extraction cycles. The optimized procedure employed 70% MeOH as extraction solvent, 120 degrees C of extraction temperature, 7 min of static extraction time, 60% flush volume and the extraction recoveries of the four compounds were nearly to 100% for two cycles. The HPLC conditions are as follows: SinoChrom ODS BP C18 (4.6 mm x 200 mm, 5 microm) column, acetonitrile and 0.10% phosphoric acid solution as mobile phase, flow rate is 1.0 mL min(-1), detection length of UV is 203 nm, injection volume is 10 microL. The results indicated that the developed HPLC method is simple, sensitive and reliable for the determination of four major saponins in seeds of A. chinesis Bunge with a good linearity (r2 > 0.9994), precision (relative standard deviation (R.S.D.) < 1.5%) and the recovery ranges of 95.2-97.3%. The limits of detection (LOD) of the four compounds were in the range of 0.40-0.75 microg mL(-1). This assay can be readily utilized as a quality control method for semen aesculi and other related medicinal plants.

  11. Chemical Characterization and Cytoprotective Effect of the Hydroethanol Extract from Annona coriacea Mart. (Araticum)

    PubMed Central

    Júnior, José G. A. S.; Coutinho, Henrique D. M.; Boris, Ticiana C. C.; Cristo, Janyketchuly S.; Pereira, Nara L. F.; Figueiredo, Fernando G.; Cunha, Francisco A. B.; Aquino, Pedro E. A.; Nascimento, Polyana A. C.; Mesquita, Francisco J. C.; Moreira, Paulo H. F.; Coutinho, Sáskia T. B.; Souza, Ivon T.; Teixeira, Gabriela C.; Ferreira, Najla M. N.; Farina, Eleonora O.; Torres, Cícero M. G.; Holanda, Vanderlan N.; Pereira, Vandbergue S.; Guedes, Maria I. F.

    2016-01-01

    Introduction: Annona coriacea Mart. (araticum) is a widely distributed tree in the cerrado. Its value is attributed principally to the consumption of its fruit which possesses a large nutritive potential. The objective was to identify the chemical profile and evaluate the antimicrobial and cytoprotective activity of the hydroethanol extract of A. coriacea Mart. (HEAC) leaves against the toxicity of mercury chloride. Materials and Methods: The characterization of components was carried out using high-performance liquid chromatography (HPLC). The minimum inhibitory concentration (MIC) was determined by microdilution method in broth with strains of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. For evaluation of the modulatory and cytoprotective activity of aminoglycoside antibiotics (gentamicin and amikacin) and mercury chloride (HgCl2), the substances were associated with the HEAC at subinhibitory concentrations (MIC/8). Results and Discussion: The HPLC analysis revealed the presence of flavonoids such as Luteolin (1.84%) and Quercetin (1.19%) in elevated concentrations. The HEAC presented an MIC ≥512 μg/mL and significant antagonistic action in aminoglycosides modulation, and it also showed cytoprotective activity to S. aureus (significance P < 0.0001) and E. coli (significance P < 0.05) bacteria against the mercury chloride heavy metal with significance, this action being attributed to the chelating properties of the flavonoids found in the chemical identification. Conclusions: The results acquired in this study show that the HEAC presents cytoprotective activity over the tested strains in vitro and can also present antagonistic effect when associated with aminoglycosides, reinforcing the necessity of taking caution when combining natural and pharmaceutical products. SUMMARY The hydroalcoholic extract of A. coriacea Mart. presents in vitro cytoprotective activity against the toxic effect of Hg. Abbreviations Used: HPLC-DAD: High-performance liquid chromatography with a diode array detector; MIC: Minimum inhibitory concentration; DMSO: Dimethyl sulfoxide PMID:27695264

  12. Analysis of the constituents of aqueous preparations of Stachys recta by HPLC-DAD and HPLC-ESI-MS.

    PubMed

    Karioti, Anastasia; Bolognesi, Letizia; Vincieri, Franco Francesco; Bilia, Anna Rita

    2010-09-21

    In the present study a method based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface for the simultaneous determination of phenolic constituents in three aqueous preparations of the herbal medicinal drug Stachys recta. The developed assay was simple and effective and permitted the quality control of S. recta decoctions and infusion. Overall, 30 constituents were detected and identified, belonging mainly to three classes of compounds: caffeoylquinic acids, phenylethanol glycosides and flavonoids. 15 of them were quantified having a lower limit not less than 0.02% of the lyophilized extracts. Only seven of them were previously reported in this species, while 23 were identified for the first time as constituents of S. recta. HPLC-DAD-ESI-MS analysis provided evidence for the certain identification of the main constituents and in some cases of their isomers. Eight constituents were isolated and their structure elucidated by HPLC-ESI-MS and 1D- and 2D-NMR spectroscopy. Among the investigated preparations, the infusion seems to be the best method to extract the native constituents of the plant, while decoction is a more aggressive treatment and causes partial degradation of some acylated flavonoids. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Means for phase locking the outputs of a surface emitting laser diode array

    NASA Technical Reports Server (NTRS)

    Lesh, James R. (Inventor)

    1987-01-01

    An array of diode lasers, either a two-dimensional array of surface emitting lasers, or a linear array of stripe lasers, is phase locked by a diode laser through a hologram which focuses the output of the diode laser into a set of distinct, spatially separated beams, each one focused onto the back facet of a separate diode laser of the array. The outputs of the diode lasers thus form an emitted coherent beam out of the front of the array.

  14. Edge multi-energy soft x-ray diagnostic in Experimental Advanced Superconducting Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y. L.; Xu, G. S.; Wan, B. N.

    A multi-energy soft x-ray (ME-SXR) diagnostic has been built for electron temperature profile in the edge plasma region in Experimental Advanced Superconducting Tokamak (EAST) after two rounds of campaigns. Originally, five preamplifiers were mounted inside the EAST vacuum vessel chamber attached to five vertically stacked compact diode arrays. A custom mechanical structure was designed to protect the detectors and electronics under constraints of the tangential field of view for plasma edge and the allocation of space. In the next experiment, the mechanical structure was redesigned with a barrel structure to absolutely isolate it from the vacuum vessel. Multiple shielding structuresmore » were mounted at the pinhole head to protect the metal foils from lithium coating. The pre-amplifiers were moved to the outside of the vacuum chamber to avoid introducing interference. Twisted copper cooling tube was embedded into the back-shell near the diode to limit the temperature of the preamplifiers and diode arrays during vacuum vessel baking when the temperature reached 150 °C. Electron temperature profiles were reconstructed from ME-SXR measurements using neural networks.« less

  15. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    NASA Astrophysics Data System (ADS)

    Mi, Jiaping; Li, Yuanqian; Zhou, Xiaoli; Zheng, Bo; Zhou, Ying

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%~100.9% for Iron, 92.50%~108.0% for Copper, 93.00%~110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%~12.1%. The sampling rate is 45 samples h-1. The determination results of the food samples were in good agreement between the proposed method and ICP-AES.

  16. Production, characterization and operation of Ge enriched BEGe detectors in GERDA

    NASA Astrophysics Data System (ADS)

    Agostini, M.; Allardt, M.; Andreotti, E.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Barros, N.; Baudis, L.; Bauer, C.; Becerici-Schmidt, N.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Budjáš, D.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Domula, A.; Egorov, V.; Falkenstein, R.; Freund, K.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gotti, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hegai, A.; Heisel, M.; Hemmer, S.; Heusser, G.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Ioannucci, L.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Klimenko, A.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Misiaszek, M.; Nemchenok, I.; Nisi, S.; O'Shaughnessy, C.; Palioselitis, D.; Pandola, L.; Pelczar, K.; Pessina, G.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salathe, M.; Schmitt, C.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Schönert, S.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Strecker, H.; Ur, C. A.; Vanhoefer, L.; Vasenko, A. A.; von Sturm, K.; Wagner, V.; Walter, M.; Wegmann, A.; Wester, T.; Wilsenach, H.; Wojcik, M.; Yanovich, E.; Zavarise, P.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2015-02-01

    The GERmanium Detector Array ( Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay () of Ge. Germanium detectors made of material with an enriched Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.

  17. Miniaturized time-resolved Raman spectrometer for planetary science based on a fast single photon avalanche diode detector array.

    PubMed

    Blacksberg, Jordana; Alerstam, Erik; Maruyama, Yuki; Cochrane, Corey J; Rossman, George R

    2016-02-01

    We present recent developments in time-resolved Raman spectroscopy instrumentation and measurement techniques for in situ planetary surface exploration, leading to improved performance and identification of minerals and organics. The time-resolved Raman spectrometer uses a 532 nm pulsed microchip laser source synchronized with a single photon avalanche diode array to achieve sub-nanosecond time resolution. This instrument can detect Raman spectral signatures from a wide variety of minerals and organics relevant to planetary science while eliminating pervasive background interference caused by fluorescence. We present an overview of the instrument design and operation and demonstrate high signal-to-noise ratio Raman spectra for several relevant samples of sulfates, clays, and polycyclic aromatic hydrocarbons. Finally, we present an instrument design suitable for operation on a rover or lander and discuss future directions that promise great advancement in capability.

  18. Identification of Ginkgo biloba supplements adulteration using high performance thin layer chromatography and ultra high performance liquid chromatography-diode array detector-quadrupole time of flight-mass spectometry

    USDA-ARS?s Scientific Manuscript database

    Ginkgo biloba is one of the most widely sold herbal supplements and medicines in the world. Its popularity stems to have a positive effect on memory and the circulatory system in clinical studies. As ginkgo popularity increased, non-proprietary extracts were introduced claiming to have similar phyto...

  19. Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

    NASA Astrophysics Data System (ADS)

    Bernassau, A. L.; Al-Rawhani, M.; Beeley, J.; Cumming, D. R. S.

    2013-12-01

    A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

  20. LDEF active optical system components experiment

    NASA Technical Reports Server (NTRS)

    Blue, M. D.

    1992-01-01

    A preliminary report on the Active Optical System Components Experiment is presented. This experiment contained 136 components in a six inch deep tray including lasers, infrared detectors and arrays, ultraviolet light detectors, light-emitting diodes, a light modulator, flash lamps, optical filters, glasses, and samples of surface finishes. Thermal, mechanical, and structural considerations leading to the design of the tray hardware are discussed. In general, changes in the retested component characteristics appear as much related to the passage of time as to the effects of the space environment, but organic materials, multilayer optical interference filters, and extreme-infrared reflectivity of black paints show unexpected changes.

  1. Transverse section radionuclide scanning system

    DOEpatents

    Kuhl, David E.; Edwards, Roy Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three-dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program.

  2. Coupling solid-phase microextraction and high-performance liquid chromatography for direct and sensitive determination of halogenated fungicides in wine.

    PubMed

    Millán, S; Sampedro, M C; Unceta, N; Goicolea, M A; Rodríguez, E; Barrio, R J

    2003-05-02

    A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.

  3. Simultaneous Determination of Eight Hypotensive Drugs of Various Chemical Groups in Pharmaceutical Preparations by HPLC-DAD.

    PubMed

    Stolarczyk, Mariusz; Hubicka, Urszula; Żuromska-Witek, Barbara; Krzek, Jan

    2015-01-01

    A new sensitive, simple, rapid, and precise HPLC method with diode array detection has been developed for separation and simultaneous determination of hydrochlorothiazide, furosemide, torasemide, losartane, quinapril, valsartan, spironolactone, and canrenone in combined pharmaceutical dosage forms. The chromatographic analysis of the tested drugs was performed on an ACE C18, 100 Å, 250×4.6 mm, 5 μm particle size column with 0.0.05 M phosphate buffer (pH=3.00)-acetonitrile-methanol (30+20+50 v/v/v) mobile phase at a flow rate of 1.0 mL/min. The column was thermostatted at 25°C. UV detection was performed at 230 nm. Analysis time was 10 min. The elaborated method meets the acceptance criteria for specificity, linearity, sensitivity, accuracy, and precision. The proposed method was successfully applied for the determination of the studied drugs in the selected combined dosage forms.

  4. A rapid method for the simultaneous quantification of the major tocopherols, carotenoids, free and esterified sterols in canola (Brassica napus) oil using normal phase liquid chromatography.

    PubMed

    Flakelar, Clare L; Prenzler, Paul D; Luckett, David J; Howitt, Julia A; Doran, Gregory

    2017-01-01

    A normal phase high performance liquid chromatography (HPLC) method was developed to simultaneously quantify several prominent bioactive compounds in canola oil vis. α-tocopherol, γ-tocopherol, δ-tocopherol, β-carotene, lutein, β-sitosterol, campesterol and brassicasterol. The use of sequential diode array detection (DAD) and tandem mass spectrometry (MS/MS) allowed direct injection of oils, diluted in hexane without derivatisation or saponification, greatly reducing sample preparation time, and permitting the quantification of both free sterols and intact sterol esters. Further advantages over existing methods included increased analytical selectivity, and a chromatographic run time substantially less than other reported normal phase methods. The HPLC-DAD-MS/MS method was applied to freshly extracted canola oil samples as well as commercially available canola, palm fruit, sunflower and olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. From the street to the laboratory: analytical profiles of methoxetamine, 3-methoxyeticyclidine and 3-methoxyphencyclidine and their determination in three biological matrices.

    PubMed

    De Paoli, Giorgia; Brandt, Simon D; Wallach, Jason; Archer, Roland P; Pounder, Derrick J

    2013-06-01

    Three psychoactive arylcyclohexylamines, advertised as "research chemicals," were obtained from an online retailer and characterized by gas chromatography ion trap electron and chemical ionization mass spectrometry, nuclear magnetic resonance spectroscopy and diode array detection. The three phencyclidines were identified as 2-(ethylamino)-2-(3-methoxyphenyl)cyclohexanone (methoxetamine), N-ethyl-1-(3-methoxyphenyl)cyclohexanamine and 1-[1-(3-methoxyphenyl)cyclohexyl]piperidine. A qualitative/quantitative method of analysis was developed and validated using liquid chromatography (HPLC) electrospray tandem mass spectrometry and ultraviolet (UV) detection for the determination of these compounds in blood, urine and vitreous humor. HPLC-UV proved to be a robust, accurate and precise method for the qualitative and quantitative analysis of these substances in biological fluids (0.16-5.0 mg/L), whereas the mass spectrometer was useful as a confirmatory tool.

  6. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine): A Validation Study and Application

    PubMed Central

    Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136

  7. Identification and characterization of new designer drug 4-fluoro-PV9 and α-PHP in the seized materials.

    PubMed

    Majchrzak, Milena; Rojkiewicz, Marcin; Celiński, Rafał; Kuś, Piotr; Sajewicz, Mieczysław

    In this study, we present identification and physicochemical characterization of new cathinone derivatives, 4-fluoro-PV9 and already known α-PHP in seized materials. Although the disclosure of α-PHP from an illegal product had been reported and characterized to some extent, the data on α-PHP are also presented together with those of 4-fluoro-PV9. The data of characterization for the two compounds were obtained by high-performance liquid chromatography (HPLC)-mass spectrometry and HPLC-diode array detection, electrospray ionization/ion trap mass spectrometry in MS 2 and MS 3 modes, gas chromatography-mass spectrometry, thermogravimetric analysis, differential scanning calorimetry, Fourier transform infrared spectroscopy, ultraviolet-visible spectroscopy, and nuclear magnetic resonance spectroscopy. To our knowledge, this is the first report for identification and detailed characterization of 4-fluoro-PV9 circulated on the illegal drug market.

  8. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    PubMed

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  9. Determination of flavonoids in cultivated sugarcane leaves, bagasse, juice and in transgenic sugarcane by liquid chromatography-UV detection.

    PubMed

    Colombo, Renata; Lanças, Fernando M; Yariwake, Janete H

    2006-01-20

    A high-performance liquid chromatography (HPLC) method with photo-diode array (DAD) detection was developed to separate and quantify flavonoids in sugarcane leaves and bagasse (= the crushed sugarcane refuse from juice extraction), and in sugarcane juice. Sugarcane flavonoids consist of a complex mixture of aglycones and glycosides (including flavonolignan glycosides), and the HPLC-UV method herein proposed is suitable for their quantification as total flavonoids. This method was applied to analyze samples of cultivated sugarcane, commercial juice and transgenic sugarcane leaves. Sugarcane leaves proved a promising source of flavonoids: an average of 1.10 mg of total flavonoids/g plant material was found in fresh leaves. Moreover, the flavonoid content of sugarcane juice (0.6 mg/mL) is comparable to other food sources of flavonoids previously reported. Transgenic sugarcane leaves ("Bowman-Birk" and "Kunitz") were compared with non-modified ("control") plant samples using the proposed HPLC-UV method, which indicated that the content of total flavonoids in transgenic plants is different from that in non-modified sugarcane.

  10. Multivariate curve resolution-assisted determination of pseudoephedrine and methamphetamine by HPLC-DAD in water samples.

    PubMed

    Vosough, Maryam; Mohamedian, Hadi; Salemi, Amir; Baheri, Tahmineh

    2015-02-01

    In the present study, a simple strategy based on solid-phase extraction (SPE) with a cation exchange sorbent (Finisterre SCX) followed by fast high-performance liquid chromatography (HPLC) with diode array detection coupled with chemometrics tools has been proposed for the determination of methamphetamine and pseudoephedrine in ground water and river water. At first, the HPLC and SPE conditions were optimized and the analytical performance of the method was determined. In the case of ground water, determination of analytes was successfully performed through univariate calibration curves. For river water sample, multivariate curve resolution and alternating least squares was implemented and the second-order advantage was achieved in samples containing uncalibrated interferences and uncorrected background signals. The calibration curves showed good linearity (r(2) > 0.994).The limits of detection for pseudoephedrine and methamphetamine were 0.06 and 0.08 μg/L and the average recovery values were 104.7 and 102.3% in river water, respectively. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Validation of AN Hplc-Dad Method for the Classification of Green Teas

    NASA Astrophysics Data System (ADS)

    Yu, Jingbo; Ye, Nengsheng; Gu, Xuexin; Liu, Ni

    A reversed phase high performance liquid chromatography (RP-HPLC) separation coupled with diode array detection (DAD) and electrospray ionization mass spectrometer (ESI/MS) was developed and optimized for the classification of green teas. Five catechins [epigallocatechin (EGC), epigallocatechin gallate (EGCG), epicatechin (EC), gallocatechin gallate (GCG), epicatechin gallate (ECG)] had been identified and quantified by the HPLC-DAD-ESI/MS/MS method. The limit of detection (LOD) of five catechins was within the range of 1.25-15 ng. All the analytes exhibited good linearity up to 2500 ng. These compounds were considered as chemical descriptors to define groups of green teas. Chemometric methods including principal component analysis (PCA) and hierarchical cluster analysis (HCA) were applied for the purpose. Twelve green tea samples originating from different regions were subjected to reveal the natural groups. The results showed that the analyzed green teas were differentiated mainly by provenance; HCA afforded an excellent performance in terms of recognition and prediction abilities. This method was accurate and reproducible, providing a potential approach for authentication of green teas.

  12. Detector with internal gain for short-wave infrared ranging applications

    NASA Astrophysics Data System (ADS)

    Fathipour, Vala; Mohseni, Hooman

    2017-09-01

    Abstarct.Highly sensitive photon detectors are regarded as the key enabling elements in many applications. Due to the low photon energy at the short-wave infrared (SWIR), photon detection and imaging at this band are very challenging. As such, many efforts in photon detector research are directed toward improving the performance of the photon detectors operating in this wavelength range. To solve these problems, we have developed an electron-injection (EI) technique. The significance of this detection mechanism is that it can provide both high efficiency and high sensitivity at room temperature, a condition that is very difficult to achieve in conventional SWIR detectors. An EI detector offers an overall system-level sensitivity enhancement due to a feedback stabilized internal avalanche-free gain. Devices exhibit an excess noise of unity, operate in linear mode, require bias voltage of a few volts, and have a cutoff wavelength of 1700 nm. We review the material system, operating principle, and development of EI detectors. The shortcomings of the first-generation devices were addressed in the second-generation detectors. Measurement on second-generation devices showed a high-speed response of ˜6 ns rise time, low jitter of less than 20 ps, high amplification of more than 2000 (at optical power levels larger than a few nW), unity excess noise factor, and low leakage current (amplified dark current ˜10 nA at a bias voltage of -3 V and at room temperature. These characteristics make EI detectors a good candidate for high-resolution flash light detection and ranging (LiDAR) applications with millimeter scale depth resolution at longer ranges compared with conventional p-i-n diodes. Based on our experimentally measured device characteristics, we compare the performance of the EI detector with commercially available linear mode InGaAs avalanche photodiode (APD) as well as a p-i-n diode using a theoretical model. Flash LiDAR images obtained by our model show that the EI detector array achieves better resolution with higher signal-to-noise compared with both the InGaAs APD and the p-i-n array (of 100×100 elements). We have designed a laboratory setup with a receiver optics aperture diameter of 3 mm that allows an EI detector (with 30-μm absorber diameter) to be used for long-range LiDAR imaging with subcentimeter resolution.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/16704869','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/16704869"><span>Procedure for and results of simultaneous determination of aromatic hydrocarbons and fatty acid methyl esters in diesel fuels by high performance liquid chromatography.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Kamiński, M; Gilgenast, E; Przyjazny, A; Romanik, G</p> <p>2006-07-28</p> <p>The content of aromatic hydrocarbons in diesel fuels is regulated by appropriate standards, and a further reduction in the allowed concentration of these hazardous substances in these fuels is expected. The content of aromatic hydrocarbons in diesel fuels is most often determined using standard methods EN-12916 or ASTM D-6591. The content of polycyclic aromatic hydrocarbons (PAHs) is determined from a single peak obtained using normal phase high-performance liquid chromatography (NP-HPLC), a column of the NH2 type, n-heptane as the eluent, refractive index detector (RID) and backflushing of the eluent. However, the methods mentioned above cannot be applied when the fuel contains fatty acid methyl esters (FAME), which lately has become more common. The content of FAME in diesel oils is determined using mid-IR spectrophotometry based on the absorption of carbonyl group. However, no standard procedure for the determination of classes of aromatic hydrocarbons in diesel fuels containing FAME is yet available. The present work describes such a modification of methods EN-12916/ASTM D-6591 that provides a simultaneous determination of individual groups of aromatic hydrocarbons, total content of polycyclic aromatic hydrocarbons and the FAME content in diesel fuels. The refractive index detector (RID) and n-heptane as the mobile phase are still used, but backflushing of the eluent is applied after the elution of all polycyclic aromatic hydrocarbons. Additionally, ultraviolet diode array detection is used for the exact determination of low contents of polycyclic aromatic hydrocarbons and to confirm the presence of FAME in the analyzed fuel.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4419227','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4419227"><span>Enhancing Phenolic Contents and Antioxidant Potentials of Antidesma thwaitesianum by Supercritical Carbon Dioxide Extraction</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Poontawee, Warut; Natakankitkul, Surapol; Wongmekiat, Orawan</p> <p>2015-01-01</p> <p>Supercritical fluid extraction (SFE) has increasingly gained attention as an alternative technique for extraction of natural products without leaving toxic residues in extracts. Antidesma thwaitesianum Muell. Arg. (Phyllanthaceae), or ma mao, has been reported to exhibit antioxidant health benefits due to its phenolic constituents. To determine whether SFE technique could impact on phenolic contents and associated antioxidant potentials, ripe fruits of Antidesma thwaitesianum (Phyllanthaceae) were extracted using supercritical carbon dioxide (SC-CO2) and conventional solvents (ethanol, water). The results showed that the SC-CO2 extract contained significantly higher yield, total phenolic, flavonoid, and proanthocyanidin contents than those obtained from ethanol and water. It also demonstrated the greatest antioxidant activities as assessed by ABTS radical cation decolorization, DPPH radical scavenging, and ferric reducing antioxidant power (FRAP) assays. Further analysis using high-performance liquid chromatography with diode array and mass spectrometry detectors (HPLC-DAD/MSD) revealed the presence of catechin as a major phenolic compound of Antidesma thwaitesianum (Phyllanthaceae), with the maximum amount detected in the SC-CO2 extract. These data indicate that SFE technology improves both quantity and quality of Antidesma thwaitesianum fruit extract. The findings added more reliability of using this technique to produce high added value products from this medicinal plant. PMID:25977832</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27614257','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27614257"><span>Extraction of polyphenols in Himanthalia elongata and determination by high performance liquid chromatography with diode array detector prior to its potential use against oxidative stress.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Belda, Mariola; Sanchez, Desiré; Bover, Elena; Prieto, Beatriz; Padrón, Carolina; Cejalvo, Dolores; Lloris, Jose Miguel</p> <p>2016-10-15</p> <p>Several studies have demonstrated the antioxidant capacity of seaweeds, which can be used for the development of biopharmaceuticals with extensive medical application. Antioxidant therapies appear to attenuate the organic deterioration originated by an excessive oxidative stress, which could prevent the harmful effects of various injuries such as ischemia-reperfusion (I/R) among others. Marine brown seaweeds play a significant role, as they are the only organisms on earth producing phlorotannins, which are polyphenols that exhibit important biological activity. To ensure obtaining an extract with the greatest antioxidant activity, some variables that affect the extraction of polyphenols are optimized, including seaweed amount, type of solvent, and time and temperature of extraction. Subsequently, the total phenolic content (TPC) and the antioxidant activity have been determined. The optimized condition was obtained for 6g of seaweed, ethanol: water proportion of 60:40 and 2h/60°C, achieving 548.33mg AG/100g seaweed and 76% of antioxidant activity. The characterization of the extracted polyphenols was made by HPLC/DAD. 11 polyphenols were identified in the extract: Phloroglucinol, Gallic Acid, Catechin, Rutin, Gentisic Acid, Chlorogenic Acid, Caffeic Acid, Coumaric, Ferulic, Myricetin and Quercetin. Copyright © 2016 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24981979','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24981979"><span>Determination of saponins and flavonoids in ivy leaf extracts using HPLC-DAD.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Yu, Miao; Shin, Young June; Kim, Nanyoung; Yoo, Guijae; Park, SeonJu; Kim, Seung Hyun</p> <p>2015-04-01</p> <p>A new method for the determination of six compounds, chlorogenic acid, rutin, nicotiflorin, hederacoside C, hederasaponin B and α-hederin, in ivy leaf extracts using high-performance liquid chromatography with diode array detector was developed. The chromatographic separation was performed on a YMC Hydrosphere C18 analytical column using a gradient elution of 0.1% phosphoric acid and acetonitrile. The method was validated in terms of specificity, linearity (r(2) > 0.9999), precision [relative standard deviation (RSD) < 0.36%] and accuracy (97.4-103.8%). The limit of detection and limit of quantification were <20.32 and 61.56 ng for all analytes, respectively. The tested compounds were found to be stable in the ivy leaf extract from 0 to 48 h, and the RSD value for each compound was <0.90%. The validated method was successfully applied to quantify all six compounds in a 30% ethanol ivy leaf extract and 13 ivy leaf extract products. The results showed that all the tested products satisfied the minimum requirement for the content of hederacoside C. However, there were some differences between the contents of other constituents. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29102057','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29102057"><span>Thin-layer chromatography coupled with high performance liquid chromatography for determining tetrabromobisphenol A/S and their derivatives in soils.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Liu, Aifeng; Shen, Zhaoshuang; Tian, Yong; Shi, Rongguang; Liu, Yi; Zhao, Zongshan; Xian, Mo</p> <p>2017-12-01</p> <p>As brominated flame retardants (BFRs), tetrabromobisphenol A/S (TBBPA/S) and their derivatives have raised wide concerns owing to their widely usage, distributions and adverse effects on human health, thus monitoring these BFRs was urgently needed. In this study, a rapid and cost-effective method based on thin-layer chromatography (TLC) sample pre-treatment coupled with high performance liquid chromatography-diode array detector (HPLC-DAD) (UV=214nm) was developed for determining TBBPA/S and their derivatives in soils, including TBBPA, TBBPA bis(allyl ether) (TBBPA-BAE), TBBPA bis(2,3-dibromopropyl ether) (TBBPA-BDBPE), TBBPS bis(allyl ether) (TBBPS-BAE) and TBBPS bis(2,3-dibromopropyl ether) (TBBPS-BDBPE). The method detection limits (MDLs) and the method quantification limits (MQLs) for these BFRs ranged from 0.023 to 0.087μgg -1 dw and 0.076-0.29μgg -1 dw, respectively. The recoveries were 41-108% and both RSD of repeatability and intermediate precision were less than 11%. The developed method presented good performance for analyzing natural soil samples collected from BFRs industrial park, suggesting its great application potential for monitoring environmental TBBPA/S and their derivatives. Copyright © 2017 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/17084895','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/17084895"><span>Occurrence and risk assessment of pharmaceutically active compounds in wastewater treatment plants. A case study: Seville city (Spain).</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Santos, J L; Aparicio, I; Alonso, E</p> <p>2007-05-01</p> <p>The occurrence of four anti-inflammatory drugs (diclofenac, ibuprofen, ketoprofen and naproxen), an antiepileptic drug (carbamazepine) and a nervous stimulant (caffeine) in influent and effluent samples from four wastewater treatment plants (WWTPs) in Seville was evaluated. Removal rates in the WWTPs and risk assessment of the pharmaceutically active compounds have been studied. Analytical determination was carried out by high performance liquid chromatography (HPLC) with diode array (DAD) and fluorescence (Fl) detectors after sample clean up and concentration by solid phase extraction. All pharmaceutically active compounds, except diclofenac, were detected not only in wastewater influents but also in wastewater effluents. Mean concentrations of caffeine, carbamazepine, ketoprofen and naproxen ranged between 0.28-11.44 microg l(-1) and 0.21-2.62 microg l(-1) in influent and effluent wastewater, respectively. Ibuprofen was present in the highest concentrations in the range 12.13-373.11 microg l(-1) and 0.78-48.24 microg l(-1) in influent and effluent wastewater, respectively. Removal rates of the pharmaceuticals ranged between 6 and 98%. Risk quotients, expressed as ratios between the measured environmental concentration (MEC) and the predicted no effect concentrations (PNEC) were higher than 1 for ibuprofen and naproxen in influent wastewater and for ibuprofen in effluent wastewater.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24343590','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24343590"><span>HPLC study of migration of terephthalic acid and isophthalic acid from PET bottles into edible oils.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Khaneghah, Amin Mousavi; Limbo, Sara; Shoeibi, Shahram; Mazinani, Somayeh</p> <p>2014-08-01</p> <p>Polyethylene terephthalate (PET) containers for food oil packaging were evaluated with a newly established determination method for terephthalic acid (TPA) and isophthalic acid (IPA). The analysis of monomers, TPA and IPA that migrate from PET bottles into oils was performed using high-pressure liquid chromatography with a diode array detector. Three types of commercial oils (sunflower oil, canola oil and blended oil which included sunflower oil, soy bean oil and cottonseed oil) were bottled in PET containers. These samples were incubated for 10 days at 49 °C as accelerated test condition. The means of recovery for this method varied from 70% to 72% and from 101% to 111% for TPA and IPA, respectively. The results showed that the amounts of specific migration of TPA and IPA into the samples conform to European Union legislation that identifies specific migration limits. More important, the results highlighted a different behavior of migration as a function of the fatty acid profile. Previous investigations have been performed with food simulants such as HB307 or 20% ethanol but our study used real food samples and determined trace amounts of the migrated compounds. Further investigation will be needed to better explain the influence of fatty acid conformation on migration of PET monomers. © 2013 Society of Chemical Industry.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23411145','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23411145"><span>Characterization and quantification of racemic and meso-ethylenediamine-N,N'-bis(2-hydroxy-5-sulfophenylacetic) acid/iron (III) by ion-pair ultra-high performance liquid chromatography coupled with diode array detector and electrospray tandem mass spectrometry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Biasone, Alessandro; Cianci, Giusto; Di Tommaso, Donata; Piaggesi, Alberto; Tagliavini, Emilio; Galletti, Paola; Moretti, Fabio</p> <p>2013-03-22</p> <p>EDDHSA/Fe is a promising substitute of EDDHA/Fe to fight iron chlorosis. o,o-EDDHSA structure contains two chiral carbons giving the racemic and meso couples of stereoisomers. Ion-pair HPLC and UHPLC-UV/Vis-ESI-MS/MS methods were developed for the determination of racemic and meso-o,o-EDDHSA/Fe in commercial samples of chelates. The lack of a commercial EDDHSA standard was overcome by sulfonation of a commercial available o,o-EDDHA standard and subsequent quantification by (1)H-NMR. Assignment of configurations was carried out starting from racemic and meso-o,o-EDDHA/Fe by direct sulfonation to give the corresponding o,o-EDDHSA/Fe isomers. The performances of these methods were assessed in terms of intra and inter-day precision, linearity and selectivity. The high selectivity and lower detection limit (nanomolar) of the UHPLC-ESI-MS/MS method could allow to deepen the knowledge relative to meso and rac-o,o-EDDHSA/Fe interactions with plants, its fate in different soil conditions, its mobility and other environmental aspects. Copyright © 2013 Elsevier B.V. All rights reserved.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_16");'>16</a></li> <li><a href="#" onclick='return showDiv("page_17");'>17</a></li> <li class="active"><span>18</span></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_18 --> <div id="page_19" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_17");'>17</a></li> <li><a href="#" onclick='return showDiv("page_18");'>18</a></li> <li class="active"><span>19</span></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="361"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28895237','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28895237"><span>A Comprehensive Characterisation of Rosemary tea Obtained from Rosmarinus officinalis L. Collected in a sub-Humid Area of Tunisia.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Achour, Mariem; Mateos, Raquel; Ben Fredj, Maha; Mtiraoui, Ali; Bravo, Laura; Saguem, Saad</p> <p>2018-01-01</p> <p>Rosemary (Rosmarinus officinalis L.) is an aromatic plant common in Tunisia and it is widely consumed as a tea in traditional cuisine and in folk medicine to treat various illnesses. Currently, most research efforts have been focused on rosemary essential oil, alcoholic and aqueous extracts, however, little is reported on rosemary infusion composition. To investigate compounds present in rosemary tea obtained from Rosmarinus officinalis L. collected in a sub-humid area of Tunisia in order to assess whether the traditional rosemary tea preparation method could be considered as a reference method for rosemary's compounds extraction. Qualitative characterisation of Rosmarinus officinalis tea obtained after rosemary infusion in boiled water was determined by high performance liquid chromatography coupled with electrospray ionisation quadrupole time-of-flight mass spectrometry (HPLC-ESI-QTOF-MS). Quantitative analysis relies on high performance liquid chromatography with diode array detector (HPLC-DAD). Forty-nine compounds belonging to six families, namely flavonoids, phenolic acids, phenolic terpenes, jasmonate, phenolic glycosides, and lignans were identified. To the best of the authors' knowledge eucommin A is characterised for the first time in rosemary. Rosmarinic acid (158.13 μg/g dried rosemary) was the main compound followed then by feruloylnepitrin (100.87 μg/g) and luteolin-3'-O-(2″-O-acetyl)-β-d-glucuronide (44.04 μg/g). Among quantified compounds, luteolin-7-O-rutinoside was the compound with the lowest concentration. The infusion method allows several polyphenols present in rosemary tea to be extracted, therefore it could be a reference method for rosemary's compounds extraction. Moreover, traditional Tunisian Rosmarinus officinalis tea consumption is of interest for its rich phenolic content. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29106966','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29106966"><span>Single-step preparation of selected biological fluids for the high performance liquid chromatographic analysis of fat-soluble vitamins and antioxidants.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Lazzarino, Giacomo; Longo, Salvatore; Amorini, Angela Maria; Di Pietro, Valentina; D'Urso, Serafina; Lazzarino, Giuseppe; Belli, Antonio; Tavazzi, Barbara</p> <p>2017-12-08</p> <p>Fat-soluble vitamins and antioxidants are of relevance in health and disease. Current methods to extract these compounds from biological fluids mainly need use of multi-steps and multi organic solvents. They are time-consuming and difficult to apply to treat simultaneously large sample number. We here describe a single-step, one solvent extraction of fat-soluble vitamins and antioxidants from biological fluids, and the chromatographic separation of all-trans-retinoic acid, 25-hydroxycholecalciferol, all-trans-retinol, astaxanthin, lutein, zeaxanthin, trans-β-apo-8'-carotenal, γ-tocopherol, β-cryptoxanthin, α-tocopherol, phylloquinone, lycopene, α-carotene, β-carotene and coenzyme Q 10 . Extraction is obtained by adding one volume of biological fluid to two acetonitrile volumes, vortexing for 60s and incubating for 60min at 37°C under agitation. HPLC separation occurs in 30min using Hypersil C18, 100×4.6mm, 5μm particle size column, gradient from 70% methanol+30% H 2 O to 100% acetonitrile, flow rate of 1.0ml/min and 37°C column temperature. Compounds are revealed using highly sensitive UV-VIS diode array detector. The HPLC method suitability was assessed in terms of sensitivity, reproducibility and recovery. Using the present extraction and chromatographic conditions we obtained values of the fat-soluble vitamins and antioxidants in serum from 50 healthy controls similar to those found in literature. Additionally, the profile of these compounds was also measured in seminal plasma from 20 healthy fertile donors. Results indicate that this simple, rapid and low cost sample processing is suitable to extract fat-soluble vitamins and antioxidants from biological fluids and can be applied in clinical and nutritional studies. Copyright © 2017 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29791312','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29791312"><span>African crocus (Curculigo pilosa) and wonderful kola (Buchholzia coriacea) seeds modulate critical enzymes relevant to erectile dysfunction and oxidative stress.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Adefegha, Stephen A; Oyeleye, Sunday I; Oboh, Ganiyu</p> <p>2018-05-23</p> <p>Background The seeds of African crocus (AC) (Curculigo pilosa) and wonderful kola (WK) (Buchholzia coriacea) are commonly used in folklore medicine in managing erectile dysfunction (ED) without the full understanding of the possible mechanism of actions. This study investigated and compared the effects of aqueous extracts from the seeds of AC and WK on arginase and acetylcholinesterase (AChE) activities and some pro-oxidant [FeSO4 and sodium nitroprusside (SNP)]-induced lipid peroxidation in rat penile homogenate in vitro. Method Aqueous extracts of AC and WK were prepared, and their effects on arginase and AChE activities as well as FeSO4- and SNP-induced lipid peroxidation in rat penile homogenate were assessed. Furthermore, phenolic constituents of the extract were determined using high-performance liquid chromatography coupled with diode-array detector (HPLC-DAD). Results Both extracts exhibited concentration-dependent inhibition on arginase (AC, IC50=0.05 mg/mL; WK, IC50=0.22 mg/mL) and AChE (AC, IC50=0.68 mg/mL; WK, IC50=0.28 mg/mL) activities. The extracts also inhibited FeSO4- and SNP-induced lipid peroxidation in rat penile homogenate. HPLC-DAD analysis revealed the presence of phenolic acids (gallic, caffeic, ellagic and coumaric acids) and flavonoids (catechin, quercetin and apigenin) in AC and WK. AC had higher arginase inhibitory and antioxidative activities but lower AChE inhibitory properties when compared with WK. Conclusions These effects could explain the possible mechanistic actions of the seeds in the management/treatment of ED and could be as a result of individual and/or synergistic effect of the constituent phenolic compounds of the seeds.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24081820','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24081820"><span>Development of validated stability indicating assay method for simultaneous estimation of metformin hydrochloride and vildagliptin by RP-HPLC.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Satheeshkumar, N; Pradeepkumar, M; Shanthikumar, S; Rao, V J</p> <p>2014-03-01</p> <p>A simple, precise and stability-indicating HPLC method was developed and validated for the simultaneous determination of metformin hydrochloride (MET) and vildagliptin (VLG) in pharmaceutical dosage forms. The method involves use of easily available inexpensive laboratory reagents. The separation was achieved on Grace Cyano column (250 mm×4.6 mm) 5 µm with isocratic flow. The mobile phase was pumped at a flow rate of 1.0 mL/min, consisted of 25 mM ammonium bicarbonate buffer and acetonitrile (65:35, v/v). The UV detection was carried out at 207 nm. A linear response was observed over the concentration range of 25-125 µg/mL for MET and 50-250 µg/mL for VLG respectively. Limit of detection and limit of quantification for MET were 0.36 µg/mL and 1.22 µg/mL, and for VLG were 0.75 µg/mL and 2.51 µg/mL respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for specificity, linearity, accuracy, precision, robustness, and system suitability. Individual drugs (MET and VLG) were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions. The resultant stressed samples were analyzed by the proposed method. The method gave high resolution among the degradation products and the analytes. The peak purity of analyte peak in the stressed samples was confirmed by photo diode array detector. The proposed method was successfully applied for the quantitative analysis of MET and VLG in tablet dosage form, which will help to improve quality control and contribute to stability studies of pharmaceutical tablets containing these drugs. © Georg Thieme Verlag KG Stuttgart · New York.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28805380','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28805380"><span>Evaluating the Antibacterial Properties of Polyacetylene and Glucosinolate Compounds with Further Identification of Their Presence within Various Carrot (Daucus carota) and Broccoli (Brassica oleracea) Cultivars Using High-Performance Liquid Chromatography with a Diode Array Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Analyses.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Hinds, L; Kenny, O; Hossain, M B; Walsh, D; Sheehy, E; Evans, P; Gaffney, M; Rai, D K</p> <p>2017-08-23</p> <p>Ongoing consumer concerns over using synthetic additives in foods has strongly influenced efforts worldwide to source suitable natural alternatives. In this study, the antibacterial efficacy of polyacetylene and glucosinolate compounds was evaluated against both Gram positive and Gram negative bacterial strains. Falcarinol [minimum inhibitory concentration (MIC) = 18.8-37.6 μg/mL] demonstrated the best overall antibacterial activity, while sinigrin (MIC = 46.9-62.5 μg/mL) was the most active glucosinolate compound. High-performance liquid chromatography with a diode array detector analysis showed falcarinol [85.13-244.85 μg/g of dry weight (DW)] to be the most abundant polyacetylene within six of the eight carrot (Daucus carota) cultivars investigated. Meanwhile, sinigrin (100.2-244.3 μg/g of DW) was the most abundant glucosinolate present within the majority of broccoli (Brassica oleracea) cultivars investigated using ultra performance liquid chromatography-tandem mass spectrometry analysis. The high abundance of both falcarinol and sinigrin within these respective species suggests that they could serve as potential sources of natural antibacterial agents for use as such in food products.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19650000280','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19650000280"><span>Constant-current regulator improves tunnel diode threshold-detector performance</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Cancro, C. A.</p> <p>1965-01-01</p> <p>Grounded-base transistor is placed in a tunnel diode threshold detector circuit, and a bias voltage is applied to the tunnel diode. This provides the threshold detector with maximum voltage output and overload protection.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19500792','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19500792"><span>High-performance liquid chromatography with diode array detection coupled to electrospray time-of-flight and ion-trap tandem mass spectrometry to identify phenolic compounds from a lemon verbena extract.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Quirantes-Piné, R; Funes, L; Micol, V; Segura-Carretero, A; Fernández-Gutiérrez, A</p> <p>2009-07-10</p> <p>High-performance liquid chromatography with diode array and electrospray ionization mass spectrometric detection was used to carry out the comprehensive characterization of a lemon verbena extract with demonstrated antioxidant and antiinflammatory activity. Two different MS techniques have been coupled to HPLC: on one hand, time-of-flight mass spectrometry, and on the other hand, tandem mass spectrometry on an ion-trap. The use of a small particle size C18 column (1.8 microm) provided a great resolution and made possible the separation of several isomers. The UV-visible spectrophotometry was used to delimit the class of phenolic compound and the accurate mass measurements on time-of-flight spectrometer enabled to identify the compounds present in the extract. Finally, the fragmentation pattern obtained in MS-MS experiments confirmed the proposed structures. This procedure was able to determine many well-known phenolic compounds present in lemon verbena such as verbascoside and its derivatives, diglucuronide derivatives of apigenin and luteolin, and eukovoside. Also gardoside, verbasoside, cistanoside F, theveside, campneoside I, chrysoeriol-7-diglucuronide, forsythoside A and acacetin-7-diglucuronide were found for the first time in lemon verbena.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29165900','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29165900"><span>Development of a precolumn derivatization HPLC method with diode-array detection for the determination of amino sugars in peat and soil humic acids.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Beňo, Erik; Góra, Róbert; Hutta, Milan</p> <p>2018-02-01</p> <p>The work is focused on the development of a high-performance liquid chromatography method with diode-array detection for the separation and quantitation of the three most abundant amino sugars; d-glucosamine, d-galactosamine, and d-mannosamine. The high-performance liquid chromatography separation was carried out by reversed-phase chromatography on Chromolith Performance RP-18e monolithic column after acid hydrolysis (5 M HCl) and precolumn derivatization of samples using diethyl ethoxymethylenemalonate. Gradient elution and a mobile phase composed of ammonium formate buffer solution (10 mmol/L, pH 3.60) and methanol with flow rate of 1.0 mL/min were used. The monitoring wavelength was set at 280 nm. The limits of detection and quantitation for analytes ranged from 0.017 to 0.122 mg/L and from 0.057 to 0.407 mg/L, respectively. The proposed method was successfully applied for the determination of amino sugars in samples of humic acids isolated from different soils and peat. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23585049','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23585049"><span>Characterisation of homoflavonoids from three Ophioglossum species using liquid chromatography with diode array detection and electrospray ionisation tandem mass spectrometry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wan, Chuan-Xing; Luo, Jian-Guang; Gu, Yu-Cheng; Xu, De-Ran; Kong, Ling-Yi</p> <p>2013-01-01</p> <p>Homoflavonoids, characterised by one more carbon atom directly added to C6 -C3 -C6 backbone of flavonoids, are rich in the species of genus Ophioglossum. Up to now we have little knowledge about their MS fragmentation patterns. It is therefore necessary to investigate their MS fragmentation pathways so as to distinguish them from other types of flavonoids. To develop a rapid method for identifying homoflavonoids from Ophioglossum based on their characteristic MS fragmentation. Mass spectrometry fragmentation pathways and qualitative analysis of homoflavonoids in three ferns of Ophioglosssum were investigated by using high-performance liquid chromatography coupled with diode-array detection and electrospray ionisation tandem mass spectrometry (HPLC-DAD-ESI/MS(n) ). The analyses of the MS(n) spectra of the homoflavonoids allowed us to classify them into two types according to their fragmentation characteristics. The type I homoflavonoids, with an attached additional carbon atom to the C-3 position of the C-ring, presented the initial competing loss of H2 O and CH2 O from their aglycone ions, compared to the initial removal of H2 O or CO in the case of the type II homoflavonoids, which bear the additional carbon atom at the C-2' site of the B-ring and forming ring D. The above characteristic fragmentations of homoflavonoids were quite different from those of other flavonoids, and were successfully applied to identify homoflavonoids in the crude extracts of three Ophioglossum species. The HPLC-DAD-ESI/MS(n) method obtained in the present study provided a powerful tool for identifying homoflavonoids from ferns in the genus Ophioglossum. Copyright © 2013 John Wiley & Sons, Ltd.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/11811476','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/11811476"><span>Accumulation of HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) in indigenous and agricultural plants grown in HMX-contaminated anti-tank firing-range soil.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Groom, Carl A; Halasz, Annamaria; Paquet, Louise; Morris, Neil; Olivier, Lucie; Dubois, Charles; Hawari, Jalal</p> <p>2002-01-01</p> <p>To investigate their potential for phytoremediation, selected agricultural and indigenous terrestrial plants were examined fortheir capacity to accumulate and degrade the explosive octahydro-1 ,3,5,7-tetra nitro-1,3,5,7-tetrazocine (HMX). Plant tissue and soil extracts were analyzed for the presence of HMX and possible degradative metabolites using high-performance liquid chromatography with diode-array UV detection (HPLC-UV), micellar electrokinetic chromatography with diode-array UV detection (MEKC-UV), and HPLC with electrospray ionization mass spectrometry (LC-MS). The pattern of HMX accumulation for alfalfa (Medicago sativa), bush bean (Phaseolus vulgaris), canola (Brassica rapa), wheat (Triticum aestivum), and perennial ryegrass (Loliumperenne) grown in a controlled environment on contaminated soil from an anti-tank firing range was similar to that observed for plants (wild bergamot (Monarda fistulosa), western wheat grass (Agropyron smithii), brome grass (Bromus sitchensis), koeleria (Koeleria gracilis), goldenrod (Solidago sp.), blueberry (Vaccinium sp.), anemone (Anemone sp.), common thistle (Circium vulgare), wax-berry (Symphoricarpos albus), western sage (Artemisia gnaphalodes), and Drummond's milk vetch (Astragalus drummondii)) collected from the range. No direct evidence of plant-mediated HMX (bio)chemical transformation was provided by the available analytical methods. Traces of mononitroso-HMX were found in contaminated soil extracts and were also observed in leaf extracts. The dominant mechanism for HMX translocation and accumulation in foliar tissue was concluded to be aqueous transpirational flux and evaporation. The accumulation of HMX in the leaves of most of the selected species to levels significantly above soil concentration is relevant to the assessment of both phytoremediation potential and environmental risks.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22545288-su-characterization-novel-high-resolution-silicon-monolithic-array-small-field-commissioning-quality-assurance','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22545288-su-characterization-novel-high-resolution-silicon-monolithic-array-small-field-commissioning-quality-assurance"><span>SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Bisello, F; IBA Dosimetry, Schwarzenbruck, DE; McGlade, J</p> <p>2015-06-15</p> <p>Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and offmore » axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29857566','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29857566"><span>Detection of β-Lactams and Chloramphenicol Residues in Raw Milk-Development and Application of an HPLC-DAD Method in Comparison with Microbial Inhibition Assays.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Karageorgou, Eftychia; Christoforidou, Sofia; Ioannidou, Maria; Psomas, Evdoxios; Samouris, Georgios</p> <p>2018-06-01</p> <p>The present study was carried out to assess the detection sensitivity of four microbial inhibition assays (MIAs) in comparison with the results obtained by the High Performance Liquid Chromatography with Diode-Array Detection (HPLC-DAD) method for antibiotics of the β-lactam group and chloramphenicol in fortified raw milk samples. MIAs presented fairly good results when detecting β-lactams, whereas none were able to detect chloramphenicol at or above the permissible limits. HPLC analysis revealed high recoveries of examined compounds, whereas all detection limits observed were lower than their respective maximum residue limits (MRL) values. The extraction and clean-up procedure of antibiotics was performed by a modified matrix solid phase dispersion procedure using a mixture of Plexa by Agilent and QuEChERS as a sorbent. The HPLC method developed was validated, determining the accuracy, precision, linearity, decision limit, and detection capability. Both methods were used to monitor raw milk samples of several cows and sheep, obtained from producers in different regions of Greece, for the presence of examined antibiotic residues. Results obtained showed that MIAs could be used effectively and routinely to detect antibiotic residues in several milk types. However, in some cases, spoilage of milk samples revealed that the kits' sensitivity could be strongly affected, whereas this fact does not affect the effectiveness of HPLC-DAD analysis.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28720173','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28720173"><span>Simultaneous Determination of First-Line 4-FDC Antituberculosis Drugs by UHPLC-UV and HPLC-UV: A Comparative Study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Franco, Pedro H C; Chellini, Paula R; Oliveira, Marcone A L; Pianetti, Gerson A</p> <p>2017-07-01</p> <p>Tuberculosis is the second most deadly infectious disease, surpassed only by HIV/AIDS, and has resulted in over 1 billion deaths in the last 200 years. The World Health Organization estimates that in 2014, 9.6 million people were infected by this disease and 1.5 million had died. First-choice treatment consists of fixed-dose combination tablets containing rifampicin, isoniazid, pyrazinamide, and ethambutol hydrochloride (4-FDC). There are pharmacopeial protocols available to test 4-FDC, but they are prolonged, two-step methods. One single-step method in the literature performs the simultaneous determination by HPLC, but requires a long acquisition time. In this context, an ultra-HPLC (UHPLC) method was developed based on the HPLC method with the objective of reducing analysis time. A C18 column (1.9 µm particle size) was used with UV-diode-array detection at 238 and 282 nm. The method was found to be selective, linear, exact, precise, and robust. Samples from two batches were analyzed and the results compared with those obtained by the HPLC method, with no statistically significant differences observed (P > 0.05). This UHPLC method reduced the analysis time from 17 to 4 min, with a more than 90% reduction in sample and reagent consumption and a financial economy of almost 50-fold.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23070832','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23070832"><span>Metabolic profile of glyburide in human liver microsomes using LC-DAD-Q-TRAP-MS/MS.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ravindran, Selvan; Basu, Sudipta; Gorti, Santosh Kapil Kumar; Surve, Prashant; Sloka, Navya</p> <p>2013-05-01</p> <p>The sulfonylurea urea drug glyburide (glibenclamide) is widely used for the treatment of diabetes milletus and gestational diabetes. In previous studies monohydroxylated metabolites were identified and characterized for glyburide in different species, but the metabolite owing to the loss of cyclohexyl ring was identified only in mouse. Glyburide upon incubation with hepatic microsomes resulted in 10 metabolites for human. The current study identifies new metabolites of glyburide along with the hydroxylated metabolites that were reported earlier. The newly identified drug metabolites are dihydroxylated metabolites, a metabolite owing to the loss of cyclohexyl ring and one owing to hydroxylation with dehydrogenation. Among the 10 identified metabolites, there were six monohydroxylated metabolites, one dihydroxylated metabolite, two metabolites owing to hydroxylation and dehydrogenation, and one metabolite owing to the loss of cyclohexyl ring. New metabolites of glyburide were identified and characterized using liquid chromatography-diode array detector-quadruple-ion trap-mass spectrometry/mass spectrometry (LC-DAD-Q-TRAP-MS/MS). An enhanced mass scan-enhanced product ion scan with information-dependent acquisition mode in a Q-TRAP-MS/MS system was used to characterize the metabolites. Liquid chromatography with diode array detection was used as a complimentary technique to confirm and identify the metabolites. Metabolites formed in higher amounts were detected in both diode array detection and mass spectrometry detection. Copyright © 2012 John Wiley & Sons, Ltd.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25860209','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25860209"><span>Comparison of UHPLC and HPLC in benzodiazepines analysis of postmortem samples: a case-control study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein</p> <p>2015-04-01</p> <p>The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case-control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4554044','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4554044"><span>Comparison of UHPLC and HPLC in Benzodiazepines Analysis of Postmortem Samples</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein</p> <p>2015-01-01</p> <p>Abstract The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case–control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis. PMID:25860209</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27448455','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27448455"><span>Aqueous extract from Ipomoea asarifolia (Convolvulaceae) leaves and its phenolic compounds have anti-inflammatory activity in murine models of edema, peritonitis and air-pouch inflammation.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Furtado, Allanny A; Torres-Rêgo, Manoela; Lima, Maíra C J S; Bitencourt, Mariana A O; Estrela, Andréia Bergamo; Souza da Silva, Nayara; da Silva Siqueira, Emerson Michell; Tomaz, José Carlos; Lopes, Norberto Peporine; Silva-Júnior, Arnóbio Antônio; Zucolotto, Silvana M; Fernandes-Pedrosa, Matheus F</p> <p>2016-11-04</p> <p>Ipomoea asarifolia (Desr.) Roem. and Schult.(Convolvulaceae), popularly known as salsa or salsa-brava, is a plant of which the decoction of leaves is used in folk medicine to treat various inflammatory disorders such of dermatitis, scabies, symptoms of syphilis, skin ulcers and external wounds. However, little is known about possible compounds and mechanisms of action of the plant to support the activities reported by popular use. The study aimed to identify bioactive molecules present in the crude extract of I. asarifolia leaves and investigate the anti-inflammatory potential of this extract in different experimental in vivo models to improve the understanding on that activity. Aqueous extract of I. asarifolia leaves was prepared by decoction (1:10 m/v) and its chromatographic profile was obtained by high performance liquid chromatography coupled with diode array detector (HPLC-DAD) and liquid chromatography diode array detector coupled with mass spectrometry (LC-DAD-MS). The potential anti-inflammatory activity of the extract was assessed using the following in vivo models: xylene-induced ear edema (20, 30 and 40mg/kg), evaluating the degree of edema formation; carrageenan-induced peritonitis (10, 20 and 30mg/kg), evaluating leukocyte migration and cytokine levels (IL-1β, IL-6, IL-12 and TNF-α) at 4h; zymosan-induced air pouch inflammation (20, 30 and 40mg/kg), evaluating the kinetics of leukocyte migration by total and differential counts at 6, 24 and 48h. The same tests were conducted using pure compounds identified in the aqueous extract from I. asarifolia leaves in different doses for each experimental model. The compounds identified in the aqueous extract of I. asarifolia leaves by HPLC-DAD and LC-DAD-MS were rutin, chlorogenic acid and caffeic acid. The extract significantly reduced ear edema induced by xylene (81%, 85% and 86% for doses of 20, 30 and 40mg/kg, respectively, p<0.001), as well as cell migration in experimental models of peritonitis (70%, 78% and 83% for doses of 10, 20 and 30mg/kg, respectively, p<0.001) and air pouch inflammation (58%, 67% and 53% for doses of 20, 30 and 40mg/kg, respectively, p<0.001). In addition, the extract demonstrated the ability to significantly inhibit the production of cytokines IL-1β, IL-6, IL-12 and TNF-α (p<0.001). The secondary metabolites tested (rutin, chlorogenic acid and caffeic acid) also showed the ability to significantly (p<0.001) decrease the parameters analyzed above. This is the first study to identify and confirm these phenolic compounds in I. asarifolia leaves extract and to suggest that these compounds contribute to the anti-inflammatory activity in vivo, as reported by ethnomedicinal use of this plant. Through the different experimental models performed, we can conclude that the results obtained with the aqueous extract from I. asarifolia leaves support its popular use for the treatment of inflammatory disorders. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1012817','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1012817"><span></span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Scott, Jeffrey Wayne; Pratt, Richard M</p> <p></p> <p>A modulated backscatter radio frequency identification device includes a diode detector configured to selectively modulate a reply signal onto an incoming continuous wave; communications circuitry configured to provide a modulation control signal to the diode detector, the diode detector being configured to modulate the reply signal in response to be modulation control signal; and circuitry configured to increase impedance change at the diode detector which would otherwise not occur because the diode detector rectifies the incoming continuous wave while modulating the reply signal, whereby reducing the rectified signal increases modulation depth by removing the reverse bias effects on impedance changes.more » Methods of improving depth of modulation in a modulated backscatter radio frequency identification device are also provided.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21190690','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21190690"><span>Evaluation of a method based on liquid chromatography-diode array detector-tandem mass spectrometry for a rapid and comprehensive characterization of the fat-soluble vitamin and carotenoid profile of selected plant foods.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Gentili, Alessandra; Caretti, Fulvia</p> <p>2011-02-04</p> <p>The feasibility of using reversed-phase liquid chromatography/diode array/tandem mass spectrometry (LC-DAD-MS/MS) for a rapid and comprehensive profiling of fat soluble vitamins and pigments in some foods of plant origin (maize flour, green and golden kiwi) was evaluated. The instrumental approach was planned for obtaining two main outcomes within the same chromatographic run: (i) the quantitative analysis of ten target analytes, whose standards are commercially available; (ii) the screening of pigments occurring in the selected matrices. The quantitative analysis was performed simultaneously for four carotenoids (lutein, zeaxanthin, β-cryptoxanthin, and β-carotene) and six compounds with fat-soluble activity (α-tocopherol, δ-tocopherol, γ-tocopherol, ergocalciferol, phylloquinone and menaquinone-4), separated on a C30 reversed-phase column and detected by atmospheric pressure chemical ionization (APCI) tandem mass spectrometry, operating in Selected Reaction Monitoring (SRM) mode. Extraction procedure was based on matrix solid-phase dispersion with recoveries of all compounds under study exceeding 78 and 60% from maize flour and kiwi, respectively. The method intra-day precision ranged between 3 and 7%, while the inter-day one was below 12%. The mild isolation conditions precluded artefacts creation, such as cis-isomerization phenomena for carotenoids. During the quantitative LC-SRM determination of the ten target analytes, the identification power of the diode array detector joined to that of the triple quadrupole (QqQ) allowed the tentatively identification of several pigments (chlorophylls and carotenoids), without the aid of standards, on the basis of: (i) the UV-vis spectra recorded in the range of 200-700nm; (ii) the expected retention time; (iii) the two SRM transitions, chosen for the target carotenoids but also common to many of isomeric carotenoids occurring in the selected foods. Copyright © 2010 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2014apsp.conf..257J','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2014apsp.conf..257J"><span>First results of neutrinoless double beta decay search with the GERmanium Detector Array "GERDA"</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Janicskó Csáthy, József</p> <p>2014-06-01</p> <p>The study of neutrinoless double beta decay is the most powerful approach to the fundamental question if the neutrino is a Majorana particle, i.e. its own anti-particle. The observation of the lepton number violating neutrinoless double beta decay would establish the Majorana nature of the neutrino. Until now neutrinoless double beta decay was not observed. The GERmanium Detector Array, GERDA is a double beta decay experiment located at the INFN Gran Sasso National Laboratory, Italy. GERDA operates bare Ge diodes enriched in 76Ge in liquid argon supplemented by a water shield. The exposure accumulated adds up to 21.6 kg· yr with a background level of 1.8 · 10-2 cts/(keV·kg·yr). The results of the Phase I of the experiment are presented and the preparation of the Phase II is briefly discussed.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_17");'>17</a></li> <li><a href="#" onclick='return showDiv("page_18");'>18</a></li> <li class="active"><span>19</span></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_19 --> <div id="page_20" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_18");'>18</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li class="active"><span>20</span></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="381"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/871402','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/871402"><span>Large angle solid state position sensitive x-ray detector system</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Kurtz, David S.; Ruud, Clay O.</p> <p>1998-01-01</p> <p>A method and apparatus for x-ray measurement of certain properties of a solid material. In distinction to known methods and apparatus, this invention employs a specific fiber-optic bundle configuration, termed a reorganizer, itself known for other uses, for coherently transmitting visible light originating from the scintillation of diffracted x-radiation from the solid material gathered along a substantially one dimensional linear arc, to a two-dimensional photo-sensor array. The two-dimensional photodetector array, with its many closely packed light sensitive pixels, is employed to process the information contained in the diffracted radiation and present the information in the form of a conventional x-ray diffraction spectrum. By this arrangement, the angular range of the combined detector faces may be increased without loss of angular resolution. Further, the prohibitively expensive coupling together of a large number of individual linear diode photodetectors, which would be required to process signals generated by the diffracted radiation, is avoided.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25732613','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25732613"><span>Quality evaluation and pattern recognition analyses of marker compounds from five medicinal drugs of Rutaceae family by HPLC/PDA.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Zhao, Bing Tian; Kim, Eun Jung; Son, Kun Ho; Son, Jong Keun; Min, Byung Sun; Woo, Mi Hee</p> <p>2015-08-01</p> <p>To establish a standard of quality control and to identify different origins for the Rutaceae family [Citri Unshiu Peel (CU), Citri Unshiu Immature Peel (CI), Ponciri Immature Fructus (PI), Aurantii Immature Fructus (AI), and Aurantii Fructus (AU)], 13 standards including rutin (1), narirutin (2), naringin (3), hesperidin (4), neohesperidin (5), neoponcirin (6), poncirin (7), naringenin (8), isosinensetin (9), sinensetin (10), nobiletin (11), heptamethoxyflavone (12), and tangeretin (13) were determined by high performance liquid chromatography (HPLC)/photo-diode array (PDA) analysis. A YMC ODS C18 (250 × 4.6 mm, 5 µm) column was used and the ratio of mobile phases of water (A) and acetonitrile (B) delivered to the column for gradient elution was applied. This method was fully validated with respect to linearity, accuracy, precision, stability, and robustness. The HPLC/PDA method was applied successfully to quantify 13 major compounds in the extracts of CU, CI, PI, AI, and AU. The pattern recognition analysis combined with LC chromatographic data was performed by repeated analysis of 27 reference samples in the above five Rutaceae oriental medicinal drugs. The established HPLC method was rapid and reliable for quantitative analysis and quality control of multiple components in five Rutaceae species with different origins.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19910022411','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19910022411"><span>Scanning imaging absorption spectrometer for atmospheric chartography</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Burrows, John P.; Chance, Kelly V.</p> <p>1991-01-01</p> <p>The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY is an instrument which measures backscattered, reflected, and transmitted light from the earth's atmosphere and surface. SCIAMACHY has eight spectral channels which observe simultaneously the spectral region between 240 and 1700 nm and selected windows between 1940 and 2400 nm. Each spectral channel contains a grating and linear diode array detector. SCIAMACHY observes the atmosphere in nadir, limb, and solar and lunar occultation viewing geometries.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19950021229','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19950021229"><span>A final look at LDEF electro-optic systems components</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Blue, M. D.</p> <p>1995-01-01</p> <p>Postrecovery characteristics of LDEF electro-optic components from the GTRI tray are compared with their prelaunch characteristics and with the characteristics of similar components from related experiments. Components considered here include lasers, light-emitting diodes, semiconducting radiation detectors and arrays, optical substrates, filters, and mirrors, and specialized coatings. Our understanding of the physical effects resulting from low earth orbit are described, and guidelines and recommendations for component and materials choices are presented.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.dtic.mil/docs/citations/ADA552954','DTIC-ST'); return false;" href="http://www.dtic.mil/docs/citations/ADA552954"><span>Electroluminescence Studies on Longwavelength Indium Arsenide Quantum Dot Microcavities Grown on Gallium Arsenide</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.dtic.mil/">DTIC Science & Technology</a></p> <p></p> <p>2011-12-01</p> <p>communication links using VCSEL arrays [1, 2], medical imaging using super luminescent diodes [3], and tunable lasers capable of remotely sensing...increase the efficiency of solar cells [6, 7, 8], vastly improve photo detector sensitivity [9], and provide optical memory storage densities predicted...semiconductor lasers” Applied Physics B: Lasers and Optics, Volume 90, Number 2, 2008, Pages 339-343. 6. Nozik, A.J. “Quantum dot solar cells</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1989ApOpt..28..472B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1989ApOpt..28..472B"><span>Short- and long-term memory effects in intensified array detectors - Influence on airborne laser fluorosensor measurements</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Bristow, Michael P.; Edmonds, Curtis M.; Bundy, Donald H.; Turner, Rudolpha M.</p> <p>1989-02-01</p> <p>Phosphorescence and thermoluminescence memory effects in the phosphors of image intensifiers are investigated, with application to the performance improvement of intensified optical multichannel analyzers. Algorithms have been developed which can be used to remove these effects from airborne measurements of laser-induced fluorescence spectra of aquatic and terrestrial targets. The present method can be adapted to situations involving different gating routines, repetition rates, and diode group sizes.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.ars.usda.gov/research/publications/publication/?seqNo115=245473','TEKTRAN'); return false;" href="http://www.ars.usda.gov/research/publications/publication/?seqNo115=245473"><span>Lipid analysis via HPLC with a charged aerosol detector</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ars.usda.gov/research/publications/find-a-publication/">USDA-ARS?s Scientific Manuscript database</a></p> <p></p> <p></p> <p>Most lipid extracts are a mixture of saturated and unsaturated molecules. Therefore, the most successful HPLC detectors for the quantitative analysis of lipids have involved the use of “universal” or “mass” detectors such as flame ionization detectors (FID) and evaporative light scattering detectors...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25214353','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25214353"><span>A high performance liquid chromatography method for determination of furfural in crude palm oil.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis</p> <p>2011-09-01</p> <p>A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural. Copyright © 2011 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/9830710','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/9830710"><span>Analysis of carbendazim, benomyl, thiophanate methyl and 2,4-dichlorophenoxyacetic acid in fruits and vegetables after supercritical fluid extraction.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Anastassiades, M; Schwack, W</p> <p>1998-10-30</p> <p>Simple methods for the analysis of carbendazim, benomyl and thiophanate methyl in fruits and vegetables and of 2,4-D in citrus fruits are presented. Sample preparation involves supercritical fluid extraction with carbon dioxide and further analysis is performed without any additional clean-up by GC-MS after derivatisation or directly by HPLC-diode array detection. The SFE methods presented are clearly faster and more cost effective than traditional solvent based approaches. The recoveries, detection limits and repeatabilities achieved, meet the needs of tolerance level monitoring of these compounds in fruits and vegetables.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22560343','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22560343"><span>Simultaneous metabolite fingerprinting of hydrophilic and lipophilic compounds in Echinacea pallida by high-performance liquid chromatography with diode array and electrospray ionization-mass spectrometry detection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Pellati, Federica; Orlandini, Giulia; Benvenuti, Stefania</p> <p>2012-06-15</p> <p>In this study, a detailed phytochemical characterization of Echinacea pallida (Nutt.) Nutt. root extracts and dietary supplements was carried out for the first time by developing advanced chromatographic techniques, based on HPLC with diode array (DAD) and electrospray ionization-mass spectrometry (ESI-MS) detection (with ion trap and triple quadrupole mass analyzers), for the simultaneous analysis of hydrophilic and lipophilic secondary metabolites. The HPLC analyses were carried out on an Ascentis C(18) column (250 mm × 4.6 mm I.D., 5 μm), with a mobile phase composed by H(2)O and ACN both containing 0.1% formic acid, under gradient elution. The UV spectra, in combination with MS and MS/MS data, allowed the identification of fourteen compounds, including caffeic acid derivatives, polyacetylenes and polyenes, in the analyzed samples. MS and MS/MS data were discussed in detail and the typical fragmentation patterns of each class of secondary metabolites were identified. For the first time, a hydroperoxide intermediate was characterized as an oxidation product of one of E. pallida monocarbonylic acetylenes, providing a confirmation of the mechanism that leads to the generation of hydroxylated derivatives. The HPLC method was fully validated in agreement with ICH guidelines and then applied to real samples. The quantitative analysis indicated that there was a great variability in the amount of the active compounds in the dietary supplements containing E. pallida root extracts: the content of total caffeic acid derivatives ranged from 2.31 to 11.45 mg/g and the amount of total polyacetylenes and polyenes from 6.38 to 30.54 mg/g. In the analyzed samples, the most abundant caffeic acid derivative was found to be echinacoside. Regarding polyacetylenes and polyenes, the most representative compounds were found to be tetradec-(8Z)-ene-11,13-diyn-2-one, pentedeca-(8Z,11Z)-dien-2-one and pentadec-(8Z)-en-2-one. The developed method can be considered suitable for metabolite fingerprinting and quality control of E. pallida plant material and natural products. Copyright © 2012 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017JPhCS.777a2034A','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017JPhCS.777a2034A"><span>Radiation response and basic dosimetric characterisation of the ‘Magic Plate’</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Alrowaili, Z. A.; Lerch, M.; Petasecca, M.; Carolan, M.; Rosenfeld, A.</p> <p>2017-02-01</p> <p>Two Dimensional (2D) silicon diode arrays are often implemented in radiation therapy quality assurance (QA) applications due to their advantages such as: real-time operation (compared to the films), large dynamic range and small size (compared to ionization chambers). The Centre for Medical Radiation Physics, University of Wollongong has developed a multifunctional 2D silicon diode array known as the Magic Plate (MP) for real-time applications and is suitable as a transmission detector for photon flunce mapping (MPTM) or for in phantom dose mapping (MPDM). The paper focusses on the characterisation of the MPDM in terms of output factor and square field beam profiling in 6 MV, 10 MV and 18 MV clinical photon fields. We have found excellent agreement with three different ion chambers for all measured parameters with output factors agreeing within 1.2% and field profiles agreeing within 3% and/or 3mm. This work has important implications for the development of the MP when operating in transmission mapping mode.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25977042','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25977042"><span>Rapid method for the determination of 14 isoflavones in food using UHPLC coupled to photo diode array detection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Shim, You-Shin; Yoon, Won-Jin; Hwang, Jin-Bong; Park, Hyun-Jin; Seo, Dongwon; Ha, Jaeho</p> <p>2015-11-15</p> <p>A rapid method for the determination of 14 types of isoflavones in food using ultra-high performance liquid chromatography (UHPLC) was validated in terms of precision, accuracy, sensitivity and linearity. The UHPLC separation was performed on a reverse-phase C18 column (particle size 2 μm, i.d. 2 mm, length 100 mm) using a photo diode array detector that was fixed to 260 nm. The limits of detection and quantification of the UHPLC analyses ranged from 0.03 to 0.33 mg kg(-1). The intra-day and inter-day precision of the individual isoflavones were less than 11.77% and calibration curves exhibited good linearity (r(2) = 0.99) within the tested ranges. These results suggest that the rapid method used in this study could be available to determine of 14 types of isoflavones in a variety of food such as soy bean, black bean, red bean and soybean paste. Copyright © 2015 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016SSEle.118...36K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016SSEle.118...36K"><span>Zero-bias microwave detectors based on array of nanorectifiers coupled with a dipole antenna</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Kasjoo, Shahrir R.; Singh, Arun K.; Mat Isa, Siti S.; Ramli, Muhammad M.; Mohamad Isa, Muammar; Ahmad, Norhawati; Mohd Nor, Nurul I.; Khalid, Nazuhusna; Song, Ai Min</p> <p>2016-04-01</p> <p>We report on zero-bias microwave detection using a large array of unipolar nanodevices, known as the self-switching diodes (SSDs). The large array was realized in a single lithography step without the need of interconnection layers, hence allowing for a simple and low-cost fabrication process. The SSD array was coupled with a narrowband dipole antenna with a resonant frequency of 890 MHz, to form a simple rectenna (rectifying antenna). The extrinsic voltage responsivity and noise-equivalent-power (NEP) of the rectenna were ∼70 V/W and ∼0.18 nW/Hz1/2, respectively, measured in the far-field region at unbiased condition. Nevertheless, the estimated intrinsic voltage responsivity can achieve up to ∼5 kV/W with NEP of ∼2.6 pW/Hz1/2.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21158317','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21158317"><span>Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Eklund, Karin; Ahnesjö, Anders</p> <p>2010-11-01</p> <p>Silicon diodes are widely used as detectors for relative dose measurements in radiotherapy. The common manufacturing practice is to encapsulate the diodes in plastic for protection and to facilitate mounting in scanning devices. Diodes intended for use in photon fields commonly also have a shield of a high atomic number material (usually tungsten) integrated into the encapsulation to selectively absorb low-energy photons to which silicon diodes would otherwise over-response. However, new response models based on cavity theories and spectra calculations have been proposed for direct correction of the readout from unshielded (e.g., "electron") diodes used in photon fields. This raises the question whether it is correct to assume that the spectrum in a water phantom at the location of the detector cavity is not perturbed by the detector encapsulation materials. The aim of this work is to investigate the spectral effects of typical encapsulations, including shielding, used for clinical diodes. The effects of detector encapsulation of an unshielded and a shielded commercial diode on the spectra at the detector cavity location are studied through Monte Carlo simulations with PENELOPE-2005. Variance reduction based on correlated sampling is applied to reduce the CPU time needed for the simulations. The use of correlated sampling is found to be efficient and to not introduce any significant bias to the results. Compared to reference spectra calculated in water, the encapsulation for an unshielded diode is demonstrated to not perturb the spectrum, while a tungsten shielded diode caused not only the desired decrease in low-energy scattered photons but also a large increase of the primary electron fluence. Measurements with a shielded diode in a 6 MV photon beam proved that the shielding does not completely remove the field-size dependence of the detector response caused by the over-response from low-energy photons. Response factors of a properly corrected unshielded diode were shown to give comparable, or better, results than the traditionally used shielded diode. Spectra calculated for photon fields in water can be directly used for modeling the response of unshielded silicon diodes with plastic encapsulations. Unshielded diodes used together with appropriate corrections can replace shielded diodes in photon dose measurements.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27052973','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27052973"><span>Giant spin-torque diode sensitivity in the absence of bias magnetic field.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Fang, Bin; Carpentieri, Mario; Hao, Xiaojie; Jiang, Hongwen; Katine, Jordan A; Krivorotov, Ilya N; Ocker, Berthold; Langer, Juergen; Wang, Kang L; Zhang, Baoshun; Azzerboni, Bruno; Amiri, Pedram Khalili; Finocchio, Giovanni; Zeng, Zhongming</p> <p>2016-04-07</p> <p>Microwave detectors based on the spin-torque diode effect are among the key emerging spintronic devices. By utilizing the spin of electrons in addition to charge, they have the potential to overcome the theoretical performance limits of their semiconductor (Schottky) counterparts. However, so far, practical implementations of spin-diode microwave detectors have been limited by the necessity to apply a magnetic field. Here, we demonstrate nanoscale magnetic tunnel junction microwave detectors, exhibiting high-detection sensitivity of 75,400 mV mW(-1) at room temperature without any external bias fields, and for low-input power (micro-Watts or lower). This sensitivity is significantly larger than both state-of-the-art Schottky diode detectors and existing spintronic diodes. Micromagnetic simulations and measurements reveal the essential role of injection locking to achieve this sensitivity performance. This mechanism may provide a pathway to enable further performance improvement of spin-torque diode microwave detectors.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4829691','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4829691"><span>Giant spin-torque diode sensitivity in the absence of bias magnetic field</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Fang, Bin; Carpentieri, Mario; Hao, Xiaojie; Jiang, Hongwen; Katine, Jordan A.; Krivorotov, Ilya N.; Ocker, Berthold; Langer, Juergen; Wang, Kang L.; Zhang, Baoshun; Azzerboni, Bruno; Amiri, Pedram Khalili; Finocchio, Giovanni; Zeng, Zhongming</p> <p>2016-01-01</p> <p>Microwave detectors based on the spin-torque diode effect are among the key emerging spintronic devices. By utilizing the spin of electrons in addition to charge, they have the potential to overcome the theoretical performance limits of their semiconductor (Schottky) counterparts. However, so far, practical implementations of spin-diode microwave detectors have been limited by the necessity to apply a magnetic field. Here, we demonstrate nanoscale magnetic tunnel junction microwave detectors, exhibiting high-detection sensitivity of 75,400 mV mW−1 at room temperature without any external bias fields, and for low-input power (micro-Watts or lower). This sensitivity is significantly larger than both state-of-the-art Schottky diode detectors and existing spintronic diodes. Micromagnetic simulations and measurements reveal the essential role of injection locking to achieve this sensitivity performance. This mechanism may provide a pathway to enable further performance improvement of spin-torque diode microwave detectors. PMID:27052973</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4235651','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4235651"><span>Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>McKenzie, Elizabeth M.; Balter, Peter A.; Stingo, Francesco C.; Jones, Jimmy; Followill, David S.; Kry, Stephen F.</p> <p>2014-01-01</p> <p>Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. Conclusions: IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans. PMID:25471949</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25471949','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25471949"><span>Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>McKenzie, Elizabeth M; Balter, Peter A; Stingo, Francesco C; Jones, Jimmy; Followill, David S; Kry, Stephen F</p> <p>2014-12-01</p> <p>The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1424977-effect-production-dried-fruits-juice-from-chokeberry-aronia-melanocarpa-content-antioxidative-activity-bioactive-compounds','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1424977-effect-production-dried-fruits-juice-from-chokeberry-aronia-melanocarpa-content-antioxidative-activity-bioactive-compounds"><span>Effect of the Production of Dried Fruits and Juice from Chokeberry (Aronia melanocarpa L.) on the Content and Antioxidative Activity of Bioactive Compounds</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Oszmiański, Jan; Lachowicz, Sabina</p> <p>2016-08-22</p> <p>The aim of this study was to evaluate the production of dried fruits and juices from chokeberry as potential sources of bioactive compounds with beneficial effects on human health. Dry powders and juices from chokeberry were analyzed for the contents of sugars with high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD method), and the antioxidant capacity was analyzed by the FRAP (ferric-reducing ability of plasma) and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)) tests. Polyphenols were then identified by high performance liquid chromatography (HPLC) coupled with a tandem mass spectrometer and a photodiode-array detector (LC-PDA-ESI-MS/MS), and their quantitative analysis was carriedmore » out by UPLC-MS/MS (using a Q/TOF detector and a PDA detector). A total of 27 polyphenolic compounds was identified in chokeberry products, including 7 anthocyanins, 11 flavonols, 5 phenolic acids, 3 flavan-3-ols and 1 flavanone. Three anthocyanin derivatives were reported for the first time from chokeberry fruit. A higher activity of the bioactive compounds was determined in dried fruit pomace and in juice obtained from crushed fruits than in those from the whole fruits. In addition, the pomace was found to be a better material for the production of dry powders, compared to chokeberry fruits.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1424977','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1424977"><span>Effect of the Production of Dried Fruits and Juice from Chokeberry (Aronia melanocarpa L.) on the Content and Antioxidative Activity of Bioactive Compounds</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Oszmiański, Jan; Lachowicz, Sabina</p> <p></p> <p>The aim of this study was to evaluate the production of dried fruits and juices from chokeberry as potential sources of bioactive compounds with beneficial effects on human health. Dry powders and juices from chokeberry were analyzed for the contents of sugars with high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD method), and the antioxidant capacity was analyzed by the FRAP (ferric-reducing ability of plasma) and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)) tests. Polyphenols were then identified by high performance liquid chromatography (HPLC) coupled with a tandem mass spectrometer and a photodiode-array detector (LC-PDA-ESI-MS/MS), and their quantitative analysis was carriedmore » out by UPLC-MS/MS (using a Q/TOF detector and a PDA detector). A total of 27 polyphenolic compounds was identified in chokeberry products, including 7 anthocyanins, 11 flavonols, 5 phenolic acids, 3 flavan-3-ols and 1 flavanone. Three anthocyanin derivatives were reported for the first time from chokeberry fruit. A higher activity of the bioactive compounds was determined in dried fruit pomace and in juice obtained from crushed fruits than in those from the whole fruits. In addition, the pomace was found to be a better material for the production of dry powders, compared to chokeberry fruits.« less</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_18");'>18</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li class="active"><span>20</span></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_20 --> <div id="page_21" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li class="active"><span>21</span></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="401"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27556441','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27556441"><span>Effect of the Production of Dried Fruits and Juice from Chokeberry (Aronia melanocarpa L.) on the Content and Antioxidative Activity of Bioactive Compounds.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Oszmiański, Jan; Lachowicz, Sabina</p> <p>2016-08-22</p> <p>The aim of this study was to evaluate the production of dried fruits and juices from chokeberry as potential sources of bioactive compounds with beneficial effects on human health. Dry powders and juices from chokeberry were analyzed for the contents of sugars with high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD method), and the antioxidant capacity was analyzed by the FRAP (ferric-reducing ability of plasma) and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)) tests. Polyphenols were identified by high performance liquid chromatography (HPLC) coupled with a tandem mass spectrometer and a photodiode-array detector (LC-PDA-ESI-MS/MS), and their quantitative analysis was carried out by UPLC-MS/MS (using a Q/TOF detector and a PDA detector). A total of 27 polyphenolic compounds was identified in chokeberry products, including 7 anthocyanins, 11 flavonols, 5 phenolic acids, 3 flavan-3-ols and 1 flavanone. Three anthocyanin derivatives were reported for the first time from chokeberry fruit. A higher activity of the bioactive compounds was determined in dried fruit pomace and in juice obtained from crushed fruits than in those from the whole fruits. In addition, the pomace was found to be a better material for the production of dry powders, compared to chokeberry fruits.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22265782','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22265782"><span>Analysis of flavonoids from lotus (Nelumbo nucifera) leaves using high performance liquid chromatography/photodiode array detector tandem electrospray ionization mass spectrometry and an extraction method optimized by orthogonal design.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Chen, Sha; Wu, Ben-Hong; Fang, Jin-Bao; Liu, Yan-Ling; Zhang, Hao-Hao; Fang, Lin-Chuan; Guan, Le; Li, Shao-Hua</p> <p>2012-03-02</p> <p>The extraction protocol of flavonoids from lotus (Nelumbo nucifera) leaves was optimized through an orthogonal design. The solvent was the most important factor comparing solvent, solvent:tissue ratio, extraction time, and temperature. The highest yield of flavonoids was achieved with 70% methanol-water and a solvent:tissue ratio of 30:1 at 4 °C for 36 h. The optimized analytical method for HPLC was a multi-step gradient elution using 0.5% formic acid (A) and CH₃CN containing 0.1% formic acid (B), at a flow rate of 0.6 mL/min. Using this optimized method, thirteen flavonoids were simultaneously separated and identified by high performance liquid chromatography coupled with photodiode array detection/electrospray ionization mass spectrometry (HPLC/DAD/ESI-MS(n)). Five of the bioactive compounds are reported in lotus leaves for the first time. The flavonoid content of the leaves of three representative cultivars was assessed under the optimized extraction and HPLC analytical conditions, and the seed-producing cultivar 'Baijianlian' had the highest flavonoid content compared with rhizome-producing 'Zhimahuoulian' and wild floral cultivar 'Honglian'. Copyright © 2012 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017SPIE10229E..0AA','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017SPIE10229E..0AA"><span>High-performance integrated pick-up circuit for SPAD arrays in time-correlated single photon counting</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Acconcia, Giulia; Cominelli, Alessandro; Peronio, Pietro; Rech, Ivan; Ghioni, Massimo</p> <p>2017-05-01</p> <p>The analysis of optical signals by means of Single Photon Avalanche Diodes (SPADs) has been subject to a widespread interest in recent years. The development of multichannel high-performance Time Correlated Single Photon Counting (TCSPC) acquisition systems has undergone a fast trend. Concerning the detector performance, best in class results have been obtained resorting to custom technologies leading also to a strong dependence of the detector timing jitter from the threshold used to determine the onset of the photogenerated current flow. In this scenario, the avalanche current pick-up circuit plays a key role in determining the timing performance of the TCSPC acquisition system, especially with a large array of SPAD detectors because of electrical crosstalk issues. We developed a new current pick-up circuit based on a transimpedance amplifier structure able to extract the timing information from a 50-μm-diameter custom technology SPAD with a state-of-art timing jitter as low as 32ps and suitable to be exploited with SPAD arrays. In this paper we discuss the key features of this structure and we present a new version of the pick-up circuit that also provides quenching capabilities in order to minimize the number of interconnections required, an aspect that becomes more and more crucial in densely integrated systems.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28704725','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28704725"><span>Simultaneous estimation of lisofylline and pentoxifylline in rat plasma by high performance liquid chromatography-photodiode array detector and its application to pharmacokinetics in rat.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Italiya, Kishan S; Sharma, Saurabh; Kothari, Ishit; Chitkara, Deepak; Mittal, Anupama</p> <p>2017-09-01</p> <p>Lisofylline (LSF) is an anti-inflammatory and immunomodulatory agent with proven activity in serious infections associated with cancer chemotherapy, hyperoxia-induced acute lung injury, autoimmune disorders including type-1 diabetes (T1DM) and islet rejection after islet transplantation. It is also an active metabolite of another anti-inflammatory agent, Pentoxifylline (PTX). LSF bears immense therapeutic potential in multiple pharmacological activities and hence appropriate and accurate quantification of LSF is very important. Although a number of analytical methods for quantification of LSF and PTX have been reported for pharmacokinetics and metabolic studies, each of these have certain limitations in terms of large sample volume required, complex extraction procedure and/or use of highly sophisticated instruments like LC-MS/MS. The aim of current study is to develop a simple reversed-phase HPLC method in rat plasma for simultaneous determination of LSF and PTX with the major objective of ensuring minimum sample volume, ease of extraction, economy of analysis, selectivity and avoiding use of instruments like LC-MS/MS to ensure a widespread application of the method. A simple liquid-liquid extraction method using methylene chloride as extracting solvent was used for extracting LSF and PTX from rat plasma (200μL). Samples were then evaporated, reconstituted with mobile phase and injected into HPLC coupled with photo-diode detector (PDA). LSF, PTX and 3-isobutyl 1-methyl xanthine (IBMX, internal standard) were separated on Inertsil® ODS (C18) column (250×4.6mm, 5μm) with mobile phase consisting of A-methanol B-water (50:50v/v) run in isocratic mode at flow rate of 1mL/min for 15min and detection at 273nm. The method showed linearity in the concentration range of 50-5000ng/mL with LOD of 10ng/mL and LLOQ of 50ng/mL for both LSF and PTX. Weighted linear regression analysis was also performed on the calibration data. The mean absolute recoveries were found to be 80.47±3.44 and 80.89±3.73% for LSF and PTX respectively. The method was successfully applied for studying the pharmacokinetics of LSF and PTX after IV bolus administration at dose of 25mg/kg in Wistar rat. In conclusion, a simple, sensitive, accurate and precise reversed-phase HPLC-UV method was established for simultaneous determination of LSF and PTX in rat plasma. Copyright © 2017 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/18069705','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/18069705"><span>Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun</p> <p>2008-01-01</p> <p>A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24128561','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24128561"><span>Characterisation of Maillard reaction products derived from LEKFD--a pentapeptide found in β-lactoglobulin sequence, glycated with glucose--by tandem mass spectrometry, molecular orbital calculations and gel filtration chromatography coupled with continuous photodiode array.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Yamaguchi, Keiko; Homma, Takeshi; Nomi, Yuri; Otsuka, Yuzuru</p> <p>2014-02-15</p> <p>Maillard reaction peptides (MRPs) contribute to taste, aroma, colour, texture and biological activity. However, peptide degradation or the cross-linking of MRPs in the Maillard reaction has not been investigated clearly. A peptide of LEKFD, a part of β-lactoglobulin, was heated at 110 °C for 24h with glucose and the reaction products were analysed by HPLC with ODS, ESI-MS, ESI-MS/MS and HPLC with gel-filtration column and DAD detector. In the HPLC fractions, an imminium ion of LEK*FD, a pyrylium ion or a hydroxymethyl furylium ion of LEK*FD, and KFD and EK were detected by ESI-MS. Therefore, those products may be produced by the Maillard reaction. The molecular orbital of glycated LEKFD at the lysine epsilon-amino residue with Schiff base form was calculated by MOPAC. HPLC with gel-filtration column showed cross-linking and degradation of peptides. Copyright © 2013 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27041855','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27041855"><span>Reverse Phase-ultra Flow Liquid Chromatography-diode Array Detector Quantification of Anticancerous and Antidiabetic Drug Mangiferin from 11 Species of Swertia from India.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Kshirsagar, Parthraj R; Gaikwad, Nikhil B; Panda, Subhasis; Hegde, Harsha V; Pai, Sandeep R</p> <p>2016-01-01</p> <p>Genus Swertia is valued for its great medicinal potential, mainly Swertia chirayita (Roxb. ex Fleming) H. Karst. is used in traditional medicine for a wide range of diseases. Mangiferin one of xanthoids is referred with enormous pharmacological potentials. The aim of the study was to quantify and compare the anticancerous and antidiabetic drug mangiferin from 11 Swertia species from India. The study also evaluates hierarchical relationships between the species based on mangiferin content using multivariate analysis. The reverse phase-ultra flow liquid chromatography-diode array detector analyses was performed and chromatographic separation was achieved on a Lichrospher 100, C18e (5 μm) column (250-4.6 mm). Mobile phase consisting of 0.2% triethylamine (pH-4 with O-phosphoric acid) and acetonitrile (85:15) was used for separation with injection volume 20 μL and detection wave length at 257 nm. Results indicated that concentration of mangiferin has been found to vary largely between Swertia species collected from different regions. Content of mangiferin was found to be highest in Swertia minor compared to other Swertia species studied herein from the Western Ghats and Himalayan region also. The same was also evident in the multivariate analysis, wherein S. chirayita, S. minor and Swertia paniculata made a separate clade. Conclusively, the work herein provides insights of mangiferin content from 11 Swertia species of India and also presents their hierarchical relationships. To best of the knowledge this is the first report of higher content of mangiferin from any Swertia species. The present study quantifies and compares mangiferin in 11 species of Swertia from India. The study also evaluates hierarchical relationships between the species based on mangiferin content using multivariate analysis. The mangiferin content was highest in S. minor compared to the studied Swertia species. To the best of our knowledge this is the first report of higher content of mangiferin from Swertia species. Abbreviations used: LOD: Limit of detection, LOQ: Limit of quantification, RP-UFLC-DAD: Reverse phase-ultra flow liquid chromatography-diode array detector, RSD: Relative standard deviation, SAN: Swertia angustifolia, SAP: Swertia angustifolia var. pulchella, SBI: S. bimaculata, SCH: S. chirayita, SCO: S. corymbosa, SDE: S. densifolia, SDI: S. dialatata, SLA: S. lawii, SMI: S. minor; SNE: S. nervosa, and SPA: S. paniculata.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20100011162','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20100011162"><span>Mosaic-Detector-Based Fluorescence Spectral Imager</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Son, Kyung-Ah; Moon, Jeong</p> <p>2007-01-01</p> <p>A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19798487','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19798487"><span>Comparison of extraction methods for the analysis of natural dyes in historical textiles by high-performance liquid chromatography.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Valianou, Lemonia; Karapanagiotis, Ioannis; Chryssoulakis, Yannis</p> <p>2009-12-01</p> <p>Different methods for the extraction of Dactylopius coccus Costa, Rubia tinctorum L., Isatis tinctoria L., Reseda luteola L., Curcuma longa L. and Cotinus coggygria Scop. from wool fibres are investigated using high-performance liquid chromatography with diode array detector (HPLC-DAD). The efficiencies of five extraction methods which include the use of HCl (widely used extraction method), citric acid, oxalic acid, TFA and a combination of HCOOH and EDTA are compared on the basis of the (a) number, (b) relative quantities, measured as HPLC peak areas and (c) signal-to-noise ratios (S/N) of the compounds extracted from the wool substrates. Flavonoid glycosides and curcuminoids contained in R. luteola L. and C. longa L., respectively, according to liquid chromatography with mass spectrometry (LC-MS) identifications, are not detected after treating the fibres with HCl. All the other milder methods are successful in extracting these compounds. Experiments are performed using HPLC-DAD to compare the HPLC peak areas and the S/N of the following extracted compounds: indigotin, indirubin, curcumin, demethoxycurcumin, bisdemethoxycurcumin, fisetin, sulfuretin, luteolin, luteolin-7-O-glucoside, apigenin, carminic acid, alizarin, puruprin and rubiadin. It is shown that the TFA method provides overall the best results as it gives elevated extraction yields except for fisetin, luteolin, apigenin and luteolin-7-O-glucoside and highest S/N except for fisetin and luteolin-7-O-glucoside. It is noteworthy that treatment of the fibres with the typical HCl extraction method results overall in very low S/N. The TFA method is selected for further studies, as follows. First, it is applied on silk dyed samples and compared with the HCl method. The same relative differences of the TFA and HCl methods observed for the wool dyed samples are reported for the silk dyed samples too, except for rubiadin, luteolin and apigenin. Thus, in most cases, the nature of the substrate (wool or silk) appears to have negligible effects on the relative difference of the two extraction methods. Second, the selected TFA method is applied to treat wool and silk historical samples extracted from textiles of the Mamluk period, resulting in the identification of several colouring compounds. In all extraction methods mentioned above, DMSO is used to dissolve the dyes, after acid treatment.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25829768','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25829768"><span>Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je</p> <p>2015-01-01</p> <p>Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography-mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R (2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55-7.07 μg/mL and 1.67-21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03-104.91%. The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21962368','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21962368"><span>Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Allen, Robert C; Rutan, Sarah C</p> <p>2011-10-31</p> <p>Simulated and experimental data were used to measure the effectiveness of common interpolation techniques during chromatographic alignment of comprehensive two-dimensional liquid chromatography-diode array detector (LC×LC-DAD) data. Interpolation was used to generate a sufficient number of data points in the sampled first chromatographic dimension to allow for alignment of retention times from different injections. Five different interpolation methods, linear interpolation followed by cross correlation, piecewise cubic Hermite interpolating polynomial, cubic spline, Fourier zero-filling, and Gaussian fitting, were investigated. The fully aligned chromatograms, in both the first and second chromatographic dimensions, were analyzed by parallel factor analysis to determine the relative area for each peak in each injection. A calibration curve was generated for the simulated data set. The standard error of prediction and percent relative standard deviation were calculated for the simulated peak for each technique. The Gaussian fitting interpolation technique resulted in the lowest standard error of prediction and average relative standard deviation for the simulated data. However, upon applying the interpolation techniques to the experimental data, most of the interpolation methods were not found to produce statistically different relative peak areas from each other. While most of the techniques were not statistically different, the performance was improved relative to the PARAFAC results obtained when analyzing the unaligned data. Copyright © 2011 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4378127','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4378127"><span>Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je</p> <p>2015-01-01</p> <p>Background: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. Objective: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. Materials and Methods: The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Results: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R2 > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. Conclusion: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. PMID:25829768</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25741896','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25741896"><span>Image monitoring of pharmaceutical blending processes and the determination of an end point by using a portable near-infrared imaging device based on a polychromator-type near-infrared spectrometer with a high-speed and high-resolution photo diode array detector.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Murayama, Kodai; Ishikawa, Daitaro; Genkawa, Takuma; Sugino, Hiroyuki; Komiyama, Makoto; Ozaki, Yukihiro</p> <p>2015-03-03</p> <p>In the present study we have developed a new version (ND-NIRs) of a polychromator-type near-infrared (NIR) spectrometer with a high-resolution photo diode array detector, which we built before (D-NIRs). The new version has four 5 W halogen lamps compared with the three lamps for the older version. The new version also has a condenser lens with a shorter focal point length. The increase in the number of the lamps and the shortening of the focal point of the condenser lens realize high signal-to-noise ratio and high-speed NIR imaging measurement. By using the ND-NIRs we carried out the in-line monitoring of pharmaceutical blending and determined an end point of the blending process. Moreover, to determinate a more accurate end point, a NIR image of the blending sample was acquired by means of a portable NIR imaging device based on ND-NIRs. The imaging result has demonstrated that the mixing time of 8 min is enough for homogeneous mixing. In this way the present study has demonstrated that ND-NIRs and the imaging system based on a ND-NIRs hold considerable promise for process analysis.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26654091','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26654091"><span>Quantity and quality of secoiridoids and lignans in extra virgin olive oils: the effect of two- and three-way decanters on Leccino and Raggiola olive cultivars.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Antonini, Elena; Farina, Alfonso; Scarpa, Emanuele Salvatore; Frati, Alessandra; Ninfali, Paolino</p> <p>2016-01-01</p> <p>In this investigation, 14 extra virgin olive oils (EVOOs), produced with Leccino and Raggiola olive cultivars, by a new two-way (2W) decanter were compared with 14 EVOOs produced by means of a conventional three-way (3W) decanter. The 2W EVOOs had higher phenol concentrations, as shown by high-performance liquid chromatography/diode array detection (HPLC-DAD) analysis and yielded a higher extraction of the 3,4-DHPEA-EDA (oleacein), 3,4-DHPEA-EA (oleuropein aglycone) and p-HPEA-EDA (oleocanthal). The concentrations of lignans, (+)-pinoresinol and (+)-1-acetoxypinoresinol, detected by HPLC-FLD equipment, were higher in the 2W EVOOs than they were in EVOOs produced using the 3W system. Total phenols, detected by the Folin-Ciocalteu assay, were lower than those obtained by HPLC, but they significantly correlated (p < 0.05). The antioxidant capacity (ORAC) values of 2W EVOOs were higher than those of 3W EVOOs. In conclusion, the 2W system provided high-quality phenol EVOOs and became an indispensable tool when adverse climatic conditions reduced the olive secoiridoid concentration.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5789330','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5789330"><span>Polyphenolic Compounds Analysis of Old and New Apple Cultivars and Contribution of Polyphenolic Profile to the In Vitro Antioxidant Capacity</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Kschonsek, Josephine; Wolfram, Theresa; Stöckl, Annette; Böhm, Volker</p> <p>2018-01-01</p> <p>Polyphenols are antioxidant ingredients in apples and are related to human health because of their free radical scavenging activities. The polyphenolic profiles of old and new apple cultivars (n = 15) were analysed using high-performance liquid chromatography (HPLC) with diode array detection (DAD). The in vitro antioxidant capacity was determined by total phenolic content (TPC) assay, hydrophilic trolox equivalent antioxidant capacity (H-TEAC) assay and hydrophilic oxygen radical absorbance (H-ORAC) assay. Twenty polyphenolic compounds were identified in all investigated apples by HPLC analysis. Quercetin glycosides (203 ± 108 mg/100 g) were the main polyphenols in the peel and phenolic acids (10 ± 5 mg/100 g) in the flesh. The calculated relative contribution of single compounds indicated flavonols (peel) and vitamin C (flesh) as the major contributors to the antioxidant capacity, in all cultivars investigated. The polyphenolic content (HPLC data) of the flesh differed significantly between old (29 ± 7 mg/100 g) and new (13 ± 4 mg/100 g) cultivars, and the antioxidant capacity of old apple cultivars was up to 30% stronger compared to new ones. PMID:29364189</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27522151','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27522151"><span>Development of propidium iodide as a fluorescence probe for the on-line screening of non-specific DNA-intercalators in Fufang Banbianlian Injection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Niu, Yanyan; Li, Sensen; Lin, Zongtao; Liu, Meixian; Wang, Daidong; Wang, Hong; Chen, Shizhong</p> <p>2016-09-09</p> <p>Fufang Banbianlian Injection (FBI) has been widely used as an anti-inflammatory and anti-tumor prescription. To understand the relationships between its bioactive ingredients and pharmacological efficacies, our previous study has been successfully identified some DNA-binding compounds in FBI using an established on-line screening system, in which 4',6-diamidino-2-phenylindole (DAPI) was developed as a probe. However, DAPI can be only used to screen ATT-specific DNA minor groove binders, leaving the potential active intercalators unknown in FBI. As a continuation of our studies on FBI, here we present a sensitive analytical method for rapid identification and evaluation of DNA-intercalators using propidium iodide (PI) as a fluorescent probe. We have firstly established the technique of high-performance liquid chromatography-diode-array detector-multistage mass spectrometry-deoxyribonucleic acid-propidium iodide-fluorescence detector (HPLC-DAD-MS(n)-DNA-PI-FLD) system. As a result, 38 of 58 previously identified compounds in FBI were DNA-intercalation active. Interestingly, all previously reported DNA-binders also showed intercalative activities, suggesting they are dual-mode DNA-binders. Quantitative study showed that flavonoid glycosides and chlorogenic acids were the main active compounds in FBI, and displayed similar DNA-binding ability using either DAPI or PI. In addition, 13 active compounds were used to establish the structure-activity relationships. In this study, PI was developed into an on-line method for identifying DNA-intercalators for the first time, and thus it will be a useful high-throughput screening technique for other related samples. Copyright © 2016 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016SPIE.9974E..0NF','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016SPIE.9974E..0NF"><span>Modeling of a sensitive time-of-flight flash LiDAR system</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Fathipour, V.; Wheaton, S.; Johnson, W. E.; Mohseni, H.</p> <p>2016-09-01</p> <p>used for monitoring and profiling structures, range, velocity, vibration, and air turbulence. Remote sensing in the IR region has several advantages over the visible region, including higher transmitter energy while maintaining eye-safety requirements. Electron-injection detectors are a new class of detectors with high internal avalanche-free amplification together with an excess-noise-factor of unity. They have a cutoff wavelength of 1700 nm. Furthermore, they have an extremely low jitter. The detector operates in linear-mode and requires only bias voltage of a few volts. This together with the feedback stabilized gain mechanism, makes formation of large-format high pixel density electron-injection FPAs less challenging compared to other detector technologies such as avalanche photodetectors. These characteristics make electron-injection detectors an ideal choice for flash LiDAR application with mm scale resolution at longer ranges. Based on our experimentally measured device characteristics, a detailed theoretical LiDAR model was developed. In this model we compare the performance of the electron-injection detector with commercially available linear-mode InGaAs APD from (Hamamatsu G8931-20) as well as a p-i-n diode (Hamamatsu 11193 p-i-n). Flash LiDAR images obtained by our model, show the electron-injection detector array (of 100 x 100 element) achieves better resolution with higher signal-to-noise compared with both the InGaAs APD and the p-i-n array (of 100 x 100 element).</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27569579','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27569579"><span>Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M</p> <p>2016-11-01</p> <p>Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26084730','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26084730"><span>Bioactive compounds of juices from two Brazilian grape cultivars.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>da Silva, Juliana Kelly; Cazarin, Cinthia Baú Betim; Correa, Luiz Claudio; Batista, Ângela Giovana; Furlan, Cibele Priscila Busch; Biasoto, Aline Camarão Telles; Pereira, Giuliano Elias; de Camargo, Adriano Costa; Maróstica Junior, Mário Roberto</p> <p>2016-04-01</p> <p>Grape juice consumption may prevent several chronic diseases owing to the presence of phenolic compounds, which have an important role in the reduction of oxidative stress. This study investigated the polyphenol content and antioxidant activities of grape juices from two cultivars: BRS-Cora and Isabella. Total polyphenol content (TPC), anthocyanins, antioxidant capacity (oxygen radical absorbance capacity, ferric reducing antioxidant power and 1,1-diphenyl-2-picrylhydrazyl), and phenolic profile (high-performance liquid chromatography with diode array and fluorescence detection--HPLC-DAD-FLD) were determined. BRS-Cora grape juice showed higher concentrations of total polyphenols and anthocyanins, as well as higher antioxidant potential, than those of Isabella grape juice. A significant positive correlation was found in TPC or anthocyanin contents when correlated with the remaining antioxidant assays. In addition, HPLC-DAD-FLD showed a higher total phenolic content in BRS-Cora grape juice compared to Isabella. The present results show BRS-Cora as a promising cultivar for grape juice production with an improved functional potential. © 2015 Society of Chemical Industry.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19945362','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19945362"><span>Structural characterization of trace stilbene glycosides in Lysidice brevicalyx Wei using liquid chromatography/diode-array detection/electrospray ionization tandem mass spectrometry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Hu, Youcai; Qu, Jing; Liu, Yuanyan; Yu, Shishan; Li, Jianbei; Zhang, Jinlan; Du, Dan</p> <p>2010-01-01</p> <p>The mass fragmentation patterns of stilbene glycosides isolated from the genus Lysidice were investigated by negative ion electrospray ionization tandem mass spectrometry, and the influence of collision energy on their fragmentation behavior is discussed. It is found that the presence of the Y(0)(-) and B(0)(-) ions in the MS(2) spectra is characteristic for 1-->6 linked diglycosyl stilbenes, while the Y(0)(-), Y(1)(-), and Z(1)(-) ions are representative ions of 1-->2 linked diglycosyl stilbenes. These results indicate that ESI-MS(n) in the negative ion mode can be used to differentiate 1-->6 and 1-->2 linked diglycosyl stilbenes. Based on the fragmentation rules, 9 new trace constituents were identified or tentatively characterized in a fraction of Lysidice brevicalyx by using HPLC/HRMS and HPLC-DAD/ESI-MS(n). The results of the present study can assist in on-line structural identification of analogous constituents and targeted isolation of novel compounds from crude plant extracts.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li class="active"><span>21</span></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_21 --> <div id="page_22" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li class="active"><span>22</span></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="421"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26367464','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26367464"><span>Identification of tyrosinase specific inhibitors from Xanthium strumarium fruit extract using ultrafiltration-high performance liquid chromatography.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wang, Zhiqiang; Hwang, Seung Hwan; Huang, Bo; Lim, Soon Sung</p> <p>2015-10-01</p> <p>In this study, a strategy based on ultrafiltration-high performance liquid chromatography coupled with diode array detection (UF-HPLC-DAD) was proposed for screening tyrosinase specific inhibitors in Xanthii fructus. The false negatives were distinguished by optimizing the UF-HPLC-DAD parameters to reduce the background noise; the false positives were distinguished by introducing a blocked tyrosinase in the control group for comparison. To obtain the best blocker, the competitive experiments were performed using various known ligands. Using this strategy, three competitive inhibitors (protocatechuic acid; 3,5-di-O-caffeoylquinic acid; and 1,5-di-O-caffeoylquinic acid) and one mixed-type inhibitor (chlorogenic acid) were identified. These results were verified using tyrosinase inhibition assay, kinetic analysis, and structural simulation of the complex. Our experimental results suggest that the proposed strategy could be useful for high-throughput identification of tyrosinase specific inhibitors in natural products. Copyright © 2015 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/15212452','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/15212452"><span>Identification and quantification of caffeoylquinic acids and flavonoids from artichoke (Cynara scolymus L.) heads, juice, and pomace by HPLC-DAD-ESI/MS(n).</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Schütz, Katrin; Kammerer, Dietmar; Carle, Reinhold; Schieber, Andreas</p> <p>2004-06-30</p> <p>A method for the identification and quantification of phenolic compounds from artichoke (Cynara scolymus L.) heads, juice, and pomace by HPLC with diode array and mass spectrometric detection was developed. Among the 22 major compounds, 11 caffeoylquinic acids and 8 flavonoids were detected. Quantification of individual compounds was carried out by external calibration. Apigenin 7-O-glucuronide was found to be the major flavonoid in all samples investigated. 1,5-Di-O-caffeoylquinic acid represented the major hydroxycinnamic acid, with 3890 mg/kg in artichoke heads and 3269 mg/kg in the pomace, whereas in the juice 1,3-di-O-caffeoylquinic acid (cynarin) was predominant, due to the isomerization during processing. Total phenolic contents of approximately 12 g/kg on a dry matter basis revealed that artichoke pomace is a promising source of phenolic compounds that might be recovered and used as natural antioxidants or functional food ingredients.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/16360660','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/16360660"><span>Analysis of polymeric phenolics in red wines using different techniques combined with gel permeation chromatography fractionation.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Guadalupe, Zenaida; Soldevilla, Alberto; Sáenz-Navajas, María-Pilar; Ayestarán, Belén</p> <p>2006-04-21</p> <p>A multiple-step analytical method was developed to improve the analysis of polymeric phenolics in red wines. With a common initial step based on the fractionation of wine phenolics by gel permeation chromatography (GPC), different analytical techniques were used: high-performance liquid chromatography-diode array detection (HPLC-DAD), HPLC-mass spectrometry (MS), capillary zone electrophoresis (CZE) and spectrophotometry. This method proved to be valid for analyzing different families of phenolic compounds, such as monomeric phenolics and their derivatives, polymeric pigments and proanthocyanidins. The analytical characteristics of fractionation by GPC were studied and the method was fully validated, yielding satisfactory statistical results. GPC fractionation substantially improved the analysis of polymeric pigments by CZE, in terms of response, repeatability and reproducibility. It also represented an improvement in the traditional vanillin assay used for proanthocyanidin (PA) quantification. Astringent proanthocyanidins were also analyzed using a simple combined method that allowed these compounds, for which only general indexes were available, to be quantified.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1994SPIE.2215...10T','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1994SPIE.2215...10T"><span>Dual use of photonic components in radiation environments</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Taylor, Edward W.</p> <p>1994-06-01</p> <p>The steady evolution of and increased requirement for using photonic technologies within the commercial market coupled with decreased defense spending has brought forth new national philosophies regarding widespread use of the technology in both military and commercial sectors. Many commercially available photonic components (i.e., optical fibers, laser diodes, semiconductor detectors, detector arrays, spatial light modulators, integrated optic circuitry and other similar optoelectronic and electro-optic devices are being scrutinized for utility, cost effectiveness and dual-use in a variety of applications. One important area of application is space. This paper will discuss the current state-of-the-art and utility of qualifying and using several mature photonic component technologies in commercial and defense application areas.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3552871','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3552871"><span>Changes in the contents of four active diterpenoids at different growth stages in Andrographis paniculata (Burm.f.) Nees (Chuanxinlian)</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p></p> <p>2013-01-01</p> <p>Background The therapeutic activities of Andrographis paniculata are attributed to four major active diterpenoids: andrographolide (AP1), 14-deoxy-11,12-didehydroandrographolide (AP3), neoandrographolide (AP4), and 14-deoxyandrographolide (AP6). This study aims to quantify the four active diterpenoids in various plant organs of A. paniculata at different growth stages in greenhouse and field experiments, with a developed HPLC-diode array detector (HPLC-DAD) method for simultaneous determination of these diterpenoids. Methods Plants were grown in greenhouse and in field conditions, harvested at different growth stages, and separated into different organs for determination of the four active diterpenoids by an HPLC-DAD method. Results The most abundant diterpenoid was AP6 between seedling and vegetative stages in the greenhouse experiment (13.38 to 23.71 mg/g in 2006 and 10.67 to 24.54 mg/g in 2007). High levels of AP6 were also detected in leaves at the transfer stage in the greenhouse experiment (36.05 ± 0.69 mg/g) and field experiment (30.59 ± 1.39 mg/g). The levels of AP6 then decreased as plants matured. The highest content of AP4 was in cotyledons (16.65 ± 4.48 mg/g) at the transfer stage. The highest contents of AP1 were detected in leaves at seed-forming stage in greenhouse experiment (24.72 ± 1.89 mg/g) and vegetative stage in field experiment (43.16 ± 0.92 mg/g). Flowers of A. paniculata contained high levels of AP1 (21.42 ± 3.74 mg/g). AP3 and AP4 were at low levels in leaves at all growth stages. Conclusion In A. paniculata, AP6 was at the highest level in leaves at transfer stage in both greenhouse and field experiments. AP1 was at the highest level in leaves at vegetative stage and seed-forming stage in field and greenhouse experiments, respectively. The contents of AP3 and AP4 in leaves were low at all growth stages. PMID:23320627</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20140001414','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20140001414"><span>Fast, High-Precision Readout Circuit for Detector Arrays</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Rider, David M.; Hancock, Bruce R.; Key, Richard W.; Cunningham, Thomas J.; Wrigley, Chris J.; Seshadri, Suresh; Sander, Stanley P.; Blavier, Jean-Francois L.</p> <p>2013-01-01</p> <p>The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20080014104','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20080014104"><span>Reliability of High Power Laser Diode Arrays Operating in Long Pulse Mode</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Amzajerdian, Farzin; Meadows, Byron L.; Barnes, Bruce W.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.; Baker, Nathaniel R.</p> <p>2006-01-01</p> <p>Reliability and lifetime of quasi-CW laser diode arrays are greatly influenced by their thermal characteristics. This paper examines the thermal properties of laser diode arrays operating in long pulse duration regime.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19500791','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19500791"><span>A general analytical strategy for the characterization of phenolic compounds in fruit juices by high-performance liquid chromatography with diode array detection coupled to electrospray ionization and triple quadrupole mass spectrometry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Abad-García, Beatriz; Berrueta, Luis A; Garmón-Lobato, Sergio; Gallo, Blanca; Vicente, Francisca</p> <p>2009-07-10</p> <p>In the present study, a methodology based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface and a triple quadrupole mass spectrometer for the simultaneous identification of phenolic compounds in fruit juices has been developed. 72 available phenolic compound standards from diverse families present in fruits have been studied in order to analyze their fragmentation pattern. As a result, a general strategy for the characterization of unknown phenolic compounds in fruit juices was designed: (i) taking into account its UV-visible spectrum and elution order, assign the unknown polyphenol to a polyphenol class, (ii) identify the quasi-molecular ion using positive and negative MS spectra, being supported by adducts generated with solvent or sodium and molecular complexes, (iii) determinate the pattern of glycosylation in positive mode using ESI(+)-CID MS/MS product ion scan experiments, selecting the quasi-molecular ion as precursor ion, and finally, (iv) study the identity of the aglycone through ESI(+)-CID MS/MS product ion spectra from the protonated aglycone, [Y(0)](+). This strategy was successfully employed for the characterization of known and unknown phenolic compounds in juices from 17 different fruits.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28366568','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28366568"><span>High performance liquid chromatography with photo diode array for separation and analysis of naproxen and esomeprazole in presence of their chiral impurities: Enantiomeric purity determination in tablets.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ragab, Marwa A A; El-Kimary, Eman I</p> <p>2017-05-12</p> <p>A stereoselective high performance liquid chromatographic method with diode array detection (HPLC-DAD) was introduced for S-naproxen and esomeprazole determination in tablets. The separation was achieved on a Kromasil Cellucoat chiral column using a mobile phase consisting of hexane: isopropanol: trifluoroacetic acid (TFA) (90:9.9:0.1 v/v/v). The proposed system was found to be suitable for the enantioseparation of naproxen and omeprazole biologically active isomers. After optimization of the chromatographic conditions, resolution values of 3.84 and 2.17 could be obtained for naproxen and omeprazole isomers, respectively. The method was fully validated for the determination of S-isomers of each drug in their dosage form. Also, the enentiomeric purity was determined in commercial tablet containing S-naproxen and esomeprazole. The enantiomeric purity was calculated for each drug and the chiral impurities (R-isomers) could be determined at 1% level. The method was validated and good results with respect to linearity, precision, accuracy, selectivity and robustness were obtained. The limits of detection (LOD) and quantification (LOQ) were 2.00, 6.50 and 0.10, 0.35μgmL -1 for S-naproxen and esomeprazole, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25407428','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25407428"><span>Determination of benzimidazole anthelmintics in milk and honey by monolithic fiber-based solid-phase microextraction combined with high-performance liquid chromatography-diode array detection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Zhang, Yong; Huang, Xiaojia; Yuan, Dongxing</p> <p>2015-01-01</p> <p>A porous poly(methacrylic acid-co-ethylene dimethacrylate) monolithic fiber (MEMF) for solid-phase microextraction (SPME) of five benzimidazole anthelmintics was prepared by in-situ polymerization. The effect of polymerization conditions on SPME of the target analytes was studied thoroughly. The physicochemical properties of the monolith were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy, and mercury intrusion porosimetry. Several conditions affecting the extraction efficiency were investigated and, under the optimized conditions, a simple and sensitive method for the determination of trace benzimidazoles residues in milk and honey was established by coupling MEMF-SPME with high-performance liquid chromatography-diode array detection (MEMF-SPME-HPLC-DAD). Under the optimum experimental conditions, the limits of detection (S/N = 3) of the method were 0.11-0.30 μg L(-1) for milk and 0.086-0.28 μg L(-1) for honey. Evaluation of intra-day and inter-day precision showed reproducibility was satisfactory-relative standard deviations (RSD) for both were <10 %. Finally, the method was successfully used for determination of benzimidazole residues in milk and honey. Recoveries obtained for determination of benzimidazole anthelmintics in spiked samples ranged from 72.3 to 121 %, with RSD always <11 %.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2013SPIE.8993E..2HA','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2013SPIE.8993E..2HA"><span>Integrated electronics for time-resolved array of single-photon avalanche diodes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Acconcia, G.; Crotti, M.; Rech, I.; Ghioni, M.</p> <p>2013-12-01</p> <p>The Time Correlated Single Photon Counting (TCSPC) technique has reached a prominent position among analytical methods employed in a great variety of fields, from medicine and biology (fluorescence spectroscopy) to telemetry (laser ranging) and communication (quantum cryptography). Nevertheless the development of TCSPC acquisition systems featuring both a high number of parallel channels and very high performance is still an open challenge: to satisfy the tight requirements set by the applications, a fully parallel acquisition system requires not only high efficiency single photon detectors but also a read-out electronics specifically designed to obtain the highest performance in conjunction with these sensors. To this aim three main blocks have been designed: a gigahertz bandwidth front-end stage to directly read the custom technology SPAD array avalanche current, a reconfigurable logic to route the detectors output signals to the acquisition chain and an array of time measurement circuits capable of recording the photon arrival times with picoseconds time resolution and a very high linearity. An innovative architecture based on these three circuits will feature a very high number of detectors to perform a truly parallel spatial or spectral analysis and a smaller number of high performance time-to-amplitude converter offering very high performance and a very high conversion frequency while limiting the area occupation and power dissipation. The routing logic will make the dynamic connection between the two arrays possible in order to guarantee that no information gets lost.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27291863','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27291863"><span>Enantiomeric analysis of overlapped chromatographic profiles in the presence of interferences. Determination of ibuprofen in a pharmaceutical formulation containing homatropine.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Padró, J M; Osorio-Grisales, J; Arancibia, J A; Olivieri, A C; Castells, C B</p> <p>2016-10-07</p> <p>In this work, we studied the combination of chemometric methods with chromatographic separations as a strategy applied to the analysis of enantiomers when complete enantioseparation is difficult or requires long analysis times and, in addition, the target signals have interference from the matrix. We present the determination of ibuprofen enantiomers in pharmaceutical formulations containing homatropine as interference by chiral HPLC-DAD detection in combination with partial least-squares algorithms. The method has been applied to samples containing enantiomeric ratios from 95:5 to 99.5:0.5 and coelution of interferents. The results were validated using univariate calibration and without homatropine. Relative error of the method was less than 4.0%, for both enantiomers. Limits of detection (LOD) and quantification (LOQ) for (S)-(+)-ibuprofen were 4.96×10 -10 and 1.50×10 -9 mol, respectively. LOD and LOQ for the R-(-)-ibuprofen were LOD=1.60×10 -11 mol and LOQ=4.85×10 -11 mol, respectively. Finally, the chemometric method was applied to the determination of enantiomeric purity of commercial pharmaceuticals. The ultimate goal of this research was the development of rapid, reliable, and robust methods for assessing enantiomeric purity by conventional diode array detector assisted by chemometric tools. Copyright © 2016 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28334872','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28334872"><span>HPLC-DAD-FLD Method for Simultaneous Determination of Mycotoxins in Wheat Bran.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Irakli, Maria N; Skendi, Adriana; Papageorgiou, Maria D</p> <p>2017-08-01</p> <p>Aflatoxins, deoxynivalenol, ochratoxin A and zearalenone are the most important mycotoxins that everyone on its own, in groups or simultaneously contaminate cereals. The external layers of cereal grains (bran) apart from health promoting ingredients are also the most contaminated part with reference to mycotoxin's presence. Therefore, consumption of a high fiber wheat-based diet represent an increased risk to consumer's health. The objective of this study was to develop a simple and reliable high performance liquid chromatography method for the simultaneous determination of these mycotoxins in wheat bran (WB). A double extraction was applied with phosphate buffered saline/methanol and for the clean-up a multi-immunoaffinity column was utilized. The detection was carried out with diode-array and fluorescence detectors linked with a post-column photochemical reactor. After optimization of the chromatographic conditions, all mycotoxins were eluted within ~26 min. Limits of detection for each mycotoxin (0.12-12.58 µg/kg) were below the maximum levels provisioned by European Union regulations. Good linearity was observed for the analytes (r2 ≥ 0.9980). The recovery of analyzed mycotoxins ranged from 70.2 to 105.8%, with a relative standard deviation <12%. The method was successfully applied to quantify mycotoxins in 34 WB samples obtained after pearling of grains that were collected from different regions of Greece. © Crown copyright 2017.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24148458','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24148458"><span>Identification of the specified impurities of silver sulfadiazine using a screening of degradation products in different stress physico-chemical media.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Cioroiu, Bogdan I; Lazar, Mihai I; Bello-López, Miguel A; Fernandez-Torres, Rut</p> <p>2013-11-15</p> <p>Determination of silver sulfadiazine degradation products in several stress media was carried out by high pressure liquid chromatography (HPLC) with diode array detector (DAD) and hybrid mass spectrometer triple quadrupole-linear trap. The optimal chromatographic method used a Hypercarb column with a stationary phase 100% carbon, a mobile phase composed by a mixture 45:55 formic acid 1% solution and acetonitrile and detection at 275 nm. Structure elucidation was carried out on the mass spectrometry system using same chromatographic conditions and based on MS/MS techniques. Under these conditions up to 9 possible impurities were demonstrated to be degradation products respecting silver sulfadiazine evolution under different stress conditions: temperature, acid, basic, oxidation, reduction and catalyzed photodegradation. Sulfacetamide, sulfanilic acid (4-aminobenzenesulfonic acid), aniline, pyrimidin-2-amine, 4-aminobenzenesulfonamide, 4-methylidenesulfanilaniline, 4-aminophenol, 4-amino-n-methyl benzenesulfonamide and benzenesulfonic acid were identified by mass spectrometry in order to cover the possible degradation paths of silver sulfadiazine. Kinetics were also evaluated to obtain the prediction of shelf life of the substance. The linearity domain for the method was between 0.0005 mg/ml and 0.25mg/ml for each compound. Recovery factors in accuracy determination were between 95 and 105% relative to target concentrations of silver sulfadiazine and the quantitation limit was 0.00025 mg/ml. Copyright © 2013 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2013AcSpA.106..146R','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2013AcSpA.106..146R"><span>Hybrid hard- and soft-modeling of spectrophotometric data for monitoring of ciprofloxacin and its main photodegradation products at different pH values</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Razuc, Mariela; Garrido, Mariano; Caro, Yamile S.; Teglia, Carla M.; Goicoechea, Héctor C.; Fernández Band, Beatriz S.</p> <p>2013-04-01</p> <p>A simple and fast on line spectrophotometric method combined with a hybrid hard-soft modeling multivariate curve resolution (HS-MCR) was proposed for the monitoring of photodegradation reaction of ciprofloxacin under UV radiation. The studied conditions attempt to emulate the effect of sunlight on these antibiotics that could be eventually present in the environment. The continuous flow system made it possible to study the ciprofloxacin degradation at different pH values almost at real time, avoiding errors that could arise from typical batch monitoring of the reaction. On the base of a concentration profiles obtained by previous pure soft-modeling approach, reaction pathways have been proposed for the parent compound and its photoproducts at different pH values. These kinetic models were used as a constraint in the HS-MCR analysis. The kinetic profiles and the corresponding pure response profile (UV-Vis spectra) of ciprofloxacin and its main degradation products were recovered after the application of HS-MCR analysis to the spectra recorded throughout the reaction. The observed behavior showed a good agreement with the photodegradation studies reported in the bibliography. Accordingly, the photodegradation reaction was studied by high performance liquid chromatography coupled with UV-Vis diode array detector (HPLC-DAD). The spectra recorded during the chromatographic analysis present a good correlation with the ones recovered by UV-Vis/HS-MCR method.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5454866','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5454866"><span>Chemical Profile and Antioxidant, Anti-Inflammatory, Antimutagenic and Antimicrobial Activities of Geopropolis from the Stingless Bee Melipona orbignyi</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>dos Santos, Helder Freitas; Campos, Jaqueline Ferreira; dos Santos, Cintia Miranda; Balestieri, José Benedito Perrella; Silva, Denise Brentan; Carollo, Carlos Alexandre; de Picoli Souza, Kely; Estevinho, Leticia Miranda; dos Santos, Edson Lucas</p> <p>2017-01-01</p> <p>Geopropolis is a resin mixed with mud, produced only by stingless bees. Despite being popularly known for its medicinal properties, few scientific studies have proven its biological activities. In this context, the objective of this study was to determine the chemical composition and antioxidant, anti-inflammatory, antimutagenic and antimicrobial activities of the Melipona orbignyi geopropolis. The hydroalcoholic extract of geopropolis (HEGP) was prepared and its chemical composition determined by high performance liquid chromatography coupled to diode array detector and mass spectrometry (HPLC-DAD-MS). The antioxidant activity was determined by the capture of free radicals and inhibition of lipid peroxidation in human erythrocytes. The anti-inflammatory activity was evaluated by the inhibition of the hyaluronidase enzyme and the antimutagenic action was investigated in Saccharomyces cerevisiae colonies. The antimicrobial activities were determined against bacteria and yeasts, isolated from reference strains and hospital origin. The chemical composition of HEGP included flavonoids, derivatives of glycosylated phenolic acids and terpenoids. HEGP showed high antioxidant activity, it inhibited the activity of the inflammatory enzyme hyaluronidase and reduced the mutagenic effects in S. cerevisiae. In relation to the antimicrobial activity, it promoted the death of all microorganisms evaluated. In conclusion, this study reveals for the first time the chemical composition of the HEGP of M. orbignyi and demonstrates its pharmacological properties. PMID:28467350</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/28467350','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/28467350"><span>Chemical Profile and Antioxidant, Anti-Inflammatory, Antimutagenic and Antimicrobial Activities of Geopropolis from the Stingless Bee Melipona orbignyi.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Santos, Helder Freitas Dos; Campos, Jaqueline Ferreira; Santos, Cintia Miranda Dos; Balestieri, José Benedito Perrella; Silva, Denise Brentan; Carollo, Carlos Alexandre; de Picoli Souza, Kely; Estevinho, Leticia Miranda; Dos Santos, Edson Lucas</p> <p>2017-05-03</p> <p>Geopropolis is a resin mixed with mud, produced only by stingless bees. Despite being popularly known for its medicinal properties, few scientific studies have proven its biological activities. In this context, the objective of this study was to determine the chemical composition and antioxidant, anti-inflammatory, antimutagenic and antimicrobial activities of the Melipona orbignyi geopropolis. The hydroalcoholic extract of geopropolis (HEGP) was prepared and its chemical composition determined by high performance liquid chromatography coupled to diode array detector and mass spectrometry (HPLC-DAD-MS). The antioxidant activity was determined by the capture of free radicals and inhibition of lipid peroxidation in human erythrocytes. The anti-inflammatory activity was evaluated by the inhibition of the hyaluronidase enzyme and the antimutagenic action was investigated in Saccharomyces cerevisiae colonies. The antimicrobial activities were determined against bacteria and yeasts, isolated from reference strains and hospital origin. The chemical composition of HEGP included flavonoids, derivatives of glycosylated phenolic acids and terpenoids. HEGP showed high antioxidant activity, it inhibited the activity of the inflammatory enzyme hyaluronidase and reduced the mutagenic effects in S. cerevisiae . In relation to the antimicrobial activity, it promoted the death of all microorganisms evaluated. In conclusion, this study reveals for the first time the chemical composition of the HEGP of M. orbignyi and demonstrates its pharmacological properties.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3065159','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3065159"><span>A HPLC-DAD method for the simultaneous determination of five marker components in the traditional herbal medicine Bangpungtongsung-san</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Weon, Jin Bae; Yang, Hye Jin; Ma, Jin Yeul; Ma, Choong Je</p> <p>2011-01-01</p> <p>Background: Bangpungtongsung-san, one of the traditional herbal medicines, was known to be a prescription for obesity. Objective: For the simultaneous determination of five components (paeoniflorin, 6-gingerol, decursin, geniposide, and glycyrrhizin) in Bangpungtongsung-san, a high-performance liquid chromatography with diode-array detector method was established. Materials and Methods: To develop the method, a reverse phase column, DIONEX C 18 (5 μm, 120 µ, 4.6 mm × 150 mm) was used. The mobile phase consisted of methanol and water using a gradient elution. The UV wavelength was set at 230, 240, and 254 nm. Method validation was accomplished by linearity, precision test, and recovery test. Results: All calibration curves of components showed good linearity (R 2 > 0.9959). The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01 to 0.17 μg/ml and 0.04 to 0.53 μg/ml, respectively. The relative standard deviations (RSD) value of precision test, intraday and interday tests were less than 0.43% and 1.26%. In the recovery test, results of accuracy ranged from 95.27% to 107.70% with RSD values less than 2.21%. Conclusion: This developed method was applied to the commercial Bangpungtongsung-san sample and the five marker components were separated effectively without interference of any peaks of components. PMID:21472081</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26626811','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26626811"><span>Valorization of solid wastes from chestnut industry processing: Extraction and optimization of polyphenols, tannins and ellagitannins and its potential for adhesives, cosmetic and pharmaceutical industry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Aires, Alfredo; Carvalho, Rosa; Saavedra, Maria José</p> <p>2016-02-01</p> <p>The aim of the current study was to evaluate the potential of chestnut peels to produce pomaces enhanced with tannins to be used in the formulations of wood adhesives, leather tanning or as natural antioxidants in food, cosmetic and pharmaceutical industry. An analytical procedure was planned as 2 factorial design to analyze the influence of solvent (water, Na2SO3 and NaOH at different concentrations of 1, 2, 4, and 8% in water) and extraction time (30, 60, and 120, 240, 480 and 960min) on extraction yield, pH, Stiasny index, and tannins. HPLC-diode array detector equipped with an ionization mass spectrophotometer was used to assess the polyphenol composition. Our results showed that both extraction properties and phytochemicals were significantly affected (P<0.001) by all independent factors. The main tannins identified were the hydrolyzable gallic acid, vescalagin castalagin and ellagic acid, and the condensed epigallocatechin, catechin and epicatechin. The solvent 1% Na2SO3 was more effective to extract the condensed tannins whilst hydrolyzable tannins were extracted efficiently by 1% NaOH. The multivariable analysis and the Pearson's correlation coefficients showed a direct association between Stiasny number and the average levels of condensed tannins. Copyright © 2015 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/1422327-molecular-chemistry-atmospheric-brown-carbon-inferred-from-nationwide-biomass-burning-event','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/1422327-molecular-chemistry-atmospheric-brown-carbon-inferred-from-nationwide-biomass-burning-event"><span>Molecular Chemistry of Atmospheric Brown Carbon Inferred from a Nationwide Biomass Burning Event</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Lin, Peng; Bluvshtein, Nir; Rudich, Yinon</p> <p></p> <p>Lag Ba'Omer, a nationwide bonfire festival in Israel, was chosen as a case study to investigate the influence of a major biomass burning event on the light absorption properties of atmospheric brown carbon (BrC). The chemical composition and optical properties of BrC chromophores were investigated using a high performance liquid chromatography (HPLC) platform coupled to photo diode array (PDA) and high resolution mass spectrometry (HRMS) detectors. Substantial increase of BrC light absorption coefficient was observed during the night-long biomass burning event. Most chromophores observed during the event were attributed to nitroaromatic compounds, comprising 28 elemental formulas of at least 63more » structural isomers. The NAC, in combination, accounted for 50-80% of the total visible light absorption (> 400 nm) by solvent extractable BrC. The results highlight that NAC, particular nitrophenols, are important light absorption contributors of biomass burning organic aerosol (BBOA), suggesting that night time chemistry of ·NO 3 and N 2O 5 with particles may play a significant role in atmospheric transformations of BrC. Nitrophenols and related compounds were especially important chromophores of BBOA. The absorption spectra of the BrC chromophores are influenced by the extraction solvent and solution pH, implying that the aerosol acidity is an important factor controlling the light absorption properties of BrC.« less</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li class="active"><span>22</span></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_22 --> <div id="page_23" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="441"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1422327-molecular-chemistry-atmospheric-brown-carbon-inferred-from-nationwide-biomass-burning-event','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1422327-molecular-chemistry-atmospheric-brown-carbon-inferred-from-nationwide-biomass-burning-event"><span>Molecular Chemistry of Atmospheric Brown Carbon Inferred from a Nationwide Biomass Burning Event</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Lin, Peng; Bluvshtein, Nir; Rudich, Yinon; ...</p> <p>2017-08-26</p> <p>Lag Ba'Omer, a nationwide bonfire festival in Israel, was chosen as a case study to investigate the influence of a major biomass burning event on the light absorption properties of atmospheric brown carbon (BrC). The chemical composition and optical properties of BrC chromophores were investigated using a high performance liquid chromatography (HPLC) platform coupled to photo diode array (PDA) and high resolution mass spectrometry (HRMS) detectors. Substantial increase of BrC light absorption coefficient was observed during the night-long biomass burning event. Most chromophores observed during the event were attributed to nitroaromatic compounds, comprising 28 elemental formulas of at least 63more » structural isomers. The NAC, in combination, accounted for 50-80% of the total visible light absorption (> 400 nm) by solvent extractable BrC. The results highlight that NAC, particular nitrophenols, are important light absorption contributors of biomass burning organic aerosol (BBOA), suggesting that night time chemistry of ·NO 3 and N 2O 5 with particles may play a significant role in atmospheric transformations of BrC. Nitrophenols and related compounds were especially important chromophores of BBOA. The absorption spectra of the BrC chromophores are influenced by the extraction solvent and solution pH, implying that the aerosol acidity is an important factor controlling the light absorption properties of BrC.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29314152','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29314152"><span>Optimization of pressurized liquid extraction by response surface methodology of Goji berry (Lycium barbarum L.) phenolic bioactive compounds.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Tripodo, Giusy; Ibáñez, Elena; Cifuentes, Alejandro; Gilbert-López, Bienvenida; Fanali, Chiara</p> <p>2018-01-03</p> <p>Pressurized liquid extraction (PLE) has been used for the first time in this work to extract phenolic compounds from Goji berries according to a multilevel factorial design using response surface methodology. The global yield (% w/dw, weight/dry-weight), total phenolic content (TPC), total flavonoid (TF) and antioxidant activity (determined via ABTS assay, expressed as TEAC value) were used as response variables to study the effects of temperature (50-180°C) and green solvent composition (mixtures of ethanol/water). Phenolic compounds characterization was performed by high performance liquid chromatography-diode array detector-tandem mass spectrometry (HPLC-DAD-MS/MS). The optimum PLE conditions predicted by the model were as follows: 180°C and 86% ethanol in water with a good desirability value of 0.815. The predicted conditions were confirmed experimentally and once the experimental design was validated for commercial fruit samples, the PLE extraction of phenolic compounds from three different varieties of fruit samples (Selvatico mongolo, Bigol, and Polonia) was performed. Nine phenolic compounds were tentatively identified in these extracts, including phenolic acids and their derivatives, and flavonols. The optimized PLE conditions were compared to a conventional solid-liquid extraction, demonstrating that PLE is a useful alternative to extract phenolic compounds from Goji berry. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4243257','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4243257"><span>Stability-indicating RP-HPLC Method for the Simultaneous Determination of Sitagliptin and Simvastatin in Tablets</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Ramalingam, P.; Bhaskar, V. Udaya; Reddy, Y. Padmanabha; Kumar, K. Vinod</p> <p>2014-01-01</p> <p>A new stability-indicating high-performance liquid chromatographic method for simultaneous analysis of sitagliptin and simvastatin in pharmaceutical dosage form was developed and validated. The mobile phase consisted of methanol and water (70:30, v/v) with 0.2 % of n-heptane sulfonic acid adjusted to pH 3.0 with ortho phosphoric acid was used. Retentions of sitagliptin and simvastatin were 4.3 min and 30.4 min, respectively with a flow rate of 1 ml/min on C8 (Qualisil BDS, 250×4.6 mm, 5 μ). Eluents were detected at 253 nm using photodiode diode array detector. The linear regression analysis data for the linearity plot showed correlation coefficient values of 0.9998 and 0.9993 for sitagliptin and simvastatin, with respective concentration ranges of 20-150 μg/ml and 8-60 μg/ml. The relative standard deviation for inter-day precision was lower than 2.0%. The assay of sitagliptin and simvastatin was determined in tablet dosage form was found to be within limits. Both drugs were subjected to a variety of stress conditions such as acidic, basic, oxidation, photolytic, neutral and thermal stress in order to achieve adequate degradation. Results revealed that considerable degradation was found in all stress conditions except oxidative degradations. The method has proven specificity for stability indicating assay method. PMID:25425754</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1407311-production-characterization-operation-ge-enriched-bege-detectors-gerda','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1407311-production-characterization-operation-ge-enriched-bege-detectors-gerda"><span>Production, characterization and operation of $$^{76}$$Ge enriched BEGe detectors in GERDA</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Agostini, M.; Allardt, M.; Andreotti, E.; ...</p> <p>2015-02-03</p> <p>The GERmanium Detector Array (Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of 76Ge. Germanium detectors made of material with an enriched 76Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new 76 Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present article reviews the complete production chain of these BEGe detectors including isotopic enrichment,more » purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the 76Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. Lastly, the detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/868246','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/868246"><span>Thin planar package for cooling an array of edge-emitting laser diodes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Mundinger, David C.; Benett, William J.</p> <p>1992-01-01</p> <p>A laser diode array is disclosed that includes a plurality of planar assemblies and active cooling of each assembly. The laser diode array may be operated in a long duty cycle, or in continuous operation. A laser diode bar and a microchannel heat sink are thermally coupled in a compact, thin planar assembly having the laser diode bar located proximate to one edge. In an array, a number of such thin planar assemblies are secured together in a stacked configuration, in close proximity so that the laser diodes are spaced closely. The cooling means includes a microchannel heat sink proximate to the laser diode bar to absorb heat generated by laser operation. To provide the coolant to the microchannels, each thin planar assembly comprises passageways that connect the microchannels to inlet and outlet corridors. Each inlet passageway may comprise a narrow slot that directs coolant into the microchannels and increases the velocity of flow therethrough. The corridors comprises holes extending through each of the assemblies in the array. The inlet and outlet corridors are connected to a conventional coolant circulation system. The laser diode array with active cooling has applications as an optical pump for high power solid state lasers, or by mating the diodes with fiber optic lenses. Further, the arrays can be useful in applications having space constraints and energy limitations, and in military and space applications. The arrays can be incorporated in equipment such as communications devices and active sensors.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2009IJMSp.284..108Z','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2009IJMSp.284..108Z"><span>Application of LC-MS to the analysis of dyes in objects of historical interest</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Zhang, Xian; Laursen, Richard</p> <p>2009-07-01</p> <p>High-performance liquid chromatography (HPLC) with photodiode array and mass spectrometric detection permits dyes extracted from objects of historical interest or from natural plant or animal dyestuffs to be characterized on the basis of three orthogonal properties: HPLC retention time, UV-visible spectrum and molecular mass. In the present study, we have focused primarily on yellow dyes, the bulk of which are flavonoid glycosides that would be almost impossible to characterize without mass spectrometric detection. Also critical for this analysis is a method for mild extraction of the dyes from objects (e.g., textiles) without hydrolyzing the glycosidic linkages. This was accomplished using 5% formic acid in methanol, rather than the more traditional 6 M HCl. Mass spectroscopy, besides providing the molecular mass of the dye molecule, sometimes yields additional structural data based on fragmentation patterns. In addition, coeluting compounds can often be detected using extracted ion chromatography. The utility of mass spectrometry is illustrated by the analysis of historical specimens of silk that had been dyed yellow with flavonoid glycosides from Sophora japonica (pagoda tree) and curcumins from Curcuma longa (turmeric). In addition, we have used these techniques to identify the dye type, and sometimes the specific dyestuff, in a variety of objects, including a yellow varnish from a 19th century Tibetan altar and a 3000-year-old wool mortuary textiles, from Xinjiang, China. We are using HPLC with diode array and mass spectrometric detection to create a library of analyzed dyestuffs (>200 so far; mostly plants) to serve as references for identification of dyes in objects of historical interest.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20080008180','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20080008180"><span>Linear array optical edge sensor</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Bejczy, Antal K. (Inventor); Primus, Howard C. (Inventor)</p> <p>1987-01-01</p> <p>A series of independent parallel pairs of light emitting and detecting diodes for a linear pixel array, which is laterally positioned over an edge-like discontinuity in a workpiece to be scanned, is disclosed. These independent pairs of light emitters and detectors sense along intersecting pairs of separate optical axes. A discontinuity, such as an edge in the sensed workpiece, reflects a detectable difference in the amount of light from that discontinuity in comparison to the amount of light that is reflected on either side of the discontinuity. A sequentially sychronized clamping and sampling circuit detects that difference as an electrical signal which is recovered by circuitry that exhibits an improved signal-to-noise capability for the system.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20180000061','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20180000061"><span>Qualification of Laser Diode Arrays for Mercury Laser Altimeter</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Stephen, Mark; Vasilyev, Aleksey; Schafer, John; Allan, Graham R.</p> <p>2004-01-01</p> <p>NASA's requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance of Quasi-CW, High-power, laser diode arrays under extended use is presented. We report the optical power over several hundred million pulse operation and the effect of power cycling and temperature cycling of the laser diode arrays. Data on the initial characterization of the devices is also presented.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.dtic.mil/docs/citations/ADA636864','DTIC-ST'); return false;" href="http://www.dtic.mil/docs/citations/ADA636864"><span>Silicon Based Mid Infrared SiGeSn Heterostructure Emitters and Detectors</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.dtic.mil/">DTIC Science & Technology</a></p> <p></p> <p>2016-05-16</p> <p>have investigated the surface plasmon enhancement of the GeSn p-i-n photodiode using gold metal nanostructures. We have conducted numerical...simulation of the plasmonic structure of 2D nano-hole array to tune the surface plasmon resonance into the absorption range of the GeSn active layer. Such a...diode can indeed be enhanced with the plasmonic structure on top. Within the time span of this project, we have completed one iteration of the process</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24320410','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24320410"><span>The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Espinoza, A; Beeksma, B; Petasecca, M; Fuduli, I; Porumb, C; Cutajar, D; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B</p> <p>2013-11-01</p> <p>High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named "magic phantom." The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array "magic plate" (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the (192)Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a (192)Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ. The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively. Our characterization of the designed QA "magic phantom" with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5711122','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5711122"><span>Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Crilly, Richard</p> <p>2014-01-01</p> <p>A commercial version of a synthetic single crystal diamond detector (SCDD) in a Schottky diode configuration was recently released as the new type 60019 microDiamond detector (PTW‐Freiburg, Germany). In this study we investigate the dosimetric properties of this detector to independently confirm that findings from the developing group of the SCDDs still hold true for the commercial version of the SCDDs. We further explore if the use of the microDiamond detector can be expanded to high‐energy photon beams of up to 15 MV and to large field measurements. Measurements were performed with an Elekta Synergy linear accelerator delivering 6, 10, and 15 MV X‐rays, as well as 6, 9, 12, 15, and 20 MeV electron beams. The dependence of the microdiamond detector response on absorbed dose after connecting the detector was investigated. Furthermore, the dark current of the diamond detector was observed after irradiation. Results are compared to similar results from measurements with a diamond detector type 60003. Energy dependency was investigated, as well. Photon depth‐dose curves were measured for field sizes 3×3,10×10, and 30×30cm2. PDDs were measured with the Semiflex type 31010 detector, microLion type 31018 detector, P Diode type 60016, SRS Diode type 60018, and the microDiamond type 60019 detector (all PTW‐Freiburg). Photon profiles were measured at a depth of 10 cm. Electron depth‐dose curves normalized to the dose maximum were measured with the 14×14cm2 electron cone. PDDs were measured with a Markus chamber type 23343, an E Diode type 60017 and the microDiamond type 60019 detector (all PTW‐Freiburg). Profiles were measured with the E Diode and microDiamond at half of D90,D90,D70, and D50 depths and for electron cone sizes of 6×6cm2, 14×14cm2, and 20×20cm2. Within a tolerance of 0.5% detector response of the investigated detector was stable without any preirradiation. After preirradition with approximately 250 cGy the detector response was stable within 0.1%. A dark current after irradiation was not observed. The microDiamond detector shows no energy dependence in high energy photon or electron dosimetry. Electron PDD measurements with the E Diode and microDiamond are in good agreement. However, compared to E Diode measurements, dose values in the bremsstrahlungs region are about 0.5% lower when measured with the microDiamond detector. Markus detector measurements agree with E Diode measurements in the bremsstrahlungs region. For depths larger than dmax, depth‐dose curves of photon beams measured with the microDiamond detector are in close agreement to those measured with the microLion detector for small fields and with those measured with a Semiflex 0.125 cc ionization chamber for large fields. Differences are in the range of 0.25% and less. For profile measurements, microDiamond detector measurements agree well with microLion and P Diode measurements in the high‐dose region of the profile and the penumbra region. For areas outside the open field, P Diode measurements are about 0.5%–1.0% higher than microDiamond and microLion measurements. Thus it becomes evident that the investigated diamond detector (type 60019) is suitable for a wide range of applications in high‐energy photon and electron dosimetry and is interesting for relative, as well as absolute, dosimetry. PACS numbers: 00.06, 80.87 PMID:25493512</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22816261','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22816261"><span>Application of curve resolution algorithms in the study of drug photodegradation kinetics -- the example of moclobemide.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Skibiński, Robert; Komsta, Łukasz</p> <p>2012-01-01</p> <p>The photodegradation of moclobemide was studied in methanolic media. Ultra-HPLC (UHPLC)/MS/MS analysis proved decomposition to 4-chlorobenzamide as a major degradation product and small amounts of Ro 16-3177 (4-chloro-N-[2-[(2-hydroxyethyl)amino] ethyl]benzamide) and 2-[(4-chlorobenzylidene)amino]-N-[2-ethoxyethenyl]ethenamine. The methanolic solution was investigated spectrophotometrically in the UV region, registering the spectra during 30 min of degradation. Using reference spectra and a multivariate chemometric method (multivariate curve resolution-alternating least squares), the spectra were resolved and concentration profiles were obtained. The obtained results were in good agreement with a quantitative approach, with UHPLC-diode array detection as the reference method.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2009EGUGA..11.6940S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2009EGUGA..11.6940S"><span>Quantity and quality of black carbon molecular markers as obtained by two chromatographic methods (GC-FID and HPLC-DAD) - How do results compare?</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Schneider, M. P. W.; Smittenberg, R. H.; Dittmar, T.; Schmidt, M. W. I.</p> <p>2009-04-01</p> <p>Chars produced by wildfires are an important source of black carbon (BC) in the environment. After their deposition on the soil surface they can be distributed into rivers, marine waters and sediments. The analysis of benzenepolycarboxylic acids (BPCAs) as a quantitative measure for black carbon (BC) in soil and sediment samples is a well-established method (Glaser et al., 1998; Brodowski et al., 2005). Briefly, the nitric acid oxidation of fused aromatic ring systems in BC forms eight molecular markers (BPCAs), which can be assigned to BC, and which subsequently can be quantified by GC-FID (gas chromatography with flame ionization detector). Recently, this method was modified for the quantification of BC in seawater samples using HPLC-DAD (High performance liquid chromatography with diode array detector) for the determination of individual BPCAs (Dittmar, 2008). A direct comparison of both analytical techniques is lacking but would be important for future data comparison aimed at the calculation of global BC budgets. Here we present a systematic comparison of the two BPCA quantification methods. We prepared chars under well-defined laboratory conditions. In order to cover a broad spectrum of char properties we used two sources of biomass and a wide range of pyrolysis temperatures. Chestnut hardwood chips (Castanea sativa) and rice straw (Oryza sativa) were pyrolysed at temperatures between 200 and 1000°C under a constant N2 stream. The maximum temperatures were held constant for 5 hours (Hammes et al., 2006). The BC contents of the chars have been analysed using the BPCA extraction method followed by either GC-FID or HPLC-DAD quantification. Preliminary results suggest that both methods yield similar total quantities of BPCA, and also the proportions of the individual markers are similar. Ongoing experiments will allow for a more detailed comparison of the two methods. The BPCA composition of chars formed at different temperatures and from different precursor biomass is being used for this purpose. We seek to establish a conversion factor between both methods, if required. Results show that both the GC and the HPLC method can be used for organic samples containing some silica, such as grass char. Further tests include silica-rich materials, such as soils. Ongoing methodological work aims at carbon isotope analysis (13C and 14C) on individual BPCAs isolated via HPLC. At present the HPLC method employs tetrabutyl ammonium bromide (TBAB) as a modifier for the liquid phase. TBAB is not volatile and contains carbon, it therefore prevents carbon isotopic analysis on isolated BPCAs. References Brodowski, S., Rodionov, A., Haumeier, L., Glaser, B., Amelung, W. (2005) Revised black carbon assessment using benzene polycarboxylic acids. Organic Geochemistry, 36(9), 1299-1310. Dittmar, T. (2008) The molecular level determination of black carbon in marine dissolved organic matter. Organic Geochemistry, 39(4). 396-407. Glaser, B., Haumeier, L., Guggenberger, G., Zech, W. (1998) Black carbon in soils: the use of benzenecarboxylic acids as specific markers. Organic Geochemistry, 29(4), 811-819. Hammes, K. Smernik, R. J., Skjemstad, J. O., Herzog, A., Vogt, U. F., Schmidt, M. W. I. (2006) Synthesis and characterisation of laboratory-charred grass straw (Oryza saliva) and chestnut wood (Castanea sativa) as reference materials for black carbon quantification Organic Geochemistry 37(11). 1629-1633</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19652937','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19652937"><span>Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Scherf, Christian; Peter, Christiane; Moog, Jussi; Licher, Jörg; Kara, Eugen; Zink, Klemens; Rödel, Claus; Ramm, Ulla</p> <p>2009-08-01</p> <p>Depth dose curves and lateral dose profiles should correspond to relative dose to water in any measured point, what can be more or less satisfied with different detectors. Diamond as detector material has similar dosimetric properties like water. Silicon diodes and ionization chambers are also commonly used to acquire dose profiles. The authors compared dose profiles measured in an MP3 water phantom with a diamond detector 60003, unshielded and shielded silicon diodes 60008 and 60012 and a 0.125-cm(3) thimble chamber 233642 (PTW, Freiburg, Germany) for 6- and 25-MV photons. Electron beams of 6, 12 and 18 MeV were investigated with the diamond detector, the unshielded diode and a Markus chamber 23343. The unshielded diode revealed relative dose differences at the water surface below +10% for 6-MV and +4% for 25-MV photons compared to the diamond data. These values decreased to less than 1% within the first millimeters of water depth. The shielded diode was only required to obtain correct data of the fall-off zones for photon beams larger than 10 x 10 cm(2) because of important contributions of low-energy scattered photons. For electron radiation the largest relative dose difference of -2% was observed with the unshielded silicon diode for 6 MeV within the build-up zone. Spatial resolutions were always best with the small voluminous silicon diodes. Relative dose profiles obtained with the two silicon diodes have the same degree of accuracy as with the diamond detector.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/597165','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/biblio/597165"><span>Large angle solid state position sensitive x-ray detector system</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Kurtz, D.S.; Ruud, C.O.</p> <p>1998-03-03</p> <p>A method and apparatus for x-ray measurement of certain properties of a solid material are disclosed. In distinction to known methods and apparatus, this invention employs a specific fiber-optic bundle configuration, termed a reorganizer, itself known for other uses, for coherently transmitting visible light originating from the scintillation of diffracted x-radiation from the solid material gathered along a substantially one dimensional linear arc, to a two-dimensional photo-sensor array. The two-dimensional photodetector array, with its many closely packed light sensitive pixels, is employed to process the information contained in the diffracted radiation and present the information in the form of a conventional x-ray diffraction spectrum. By this arrangement, the angular range of the combined detector faces may be increased without loss of angular resolution. Further, the prohibitively expensive coupling together of a large number of individual linear diode photodetectors, which would be required to process signals generated by the diffracted radiation, is avoided. 7 figs.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/672577','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/biblio/672577"><span>Large angle solid state position sensitive x-ray detector system</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Kurtz, D.S.; Ruud, C.O.</p> <p>1998-07-21</p> <p>A method and apparatus are disclosed for x-ray measurement of certain properties of a solid material. In distinction to known methods and apparatus, this invention employs a specific fiber-optic bundle configuration, termed a reorganizer, itself known for other uses, for coherently transmitting visible light originating from the scintillation of diffracted x-radiation from the solid material gathered along a substantially one dimensional linear arc, to a two-dimensional photo-sensor array. The two-dimensional photodetector array, with its many closely packed light sensitive pixels, is employed to process the information contained in the diffracted radiation and present the information in the form of a conventional x-ray diffraction spectrum. By this arrangement, the angular range of the combined detector faces may be increased without loss of angular resolution. Further, the prohibitively expensive coupling together of a large number of individual linear diode photodetectors, which would be required to process signals generated by the diffracted radiation, is avoided. 7 figs.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22649077-su-separating-effects-influencing-detector-response-small-mv-photon-fields','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22649077-su-separating-effects-influencing-detector-response-small-mv-photon-fields"><span>SU-F-T-490: Separating Effects Influencing Detector Response in Small MV Photon Fields</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Wegener, S; Sauer, O</p> <p>2016-06-15</p> <p>Purpose: Different detector properties influence their responses especially in field sizes below the lateral electron range. Due to the finite active volume, the detector density and electron perturbation at other structural parts, the response factor is in general field size dependent. We aimed to visualize and separate the main effects contributing to detector behavior for a variety of detector types. This was achieved in an experimental setup, shielding the field center. Thus, effects caused by scattered radiation could be examined separately. Methods: Signal ratios for field sizes down to 8 mm (SSD 90 cm, water depth 10 cm) of amore » 6MV beam from a Siemens Primus LINAC were recorded with several detectors: PTW microDiamond and PinPoint ionization chamber, shielded diodes (PTW P-60008, IBA PFD and SNC Edge) and unshielded diodes (PTW E-60012 and IBA SFD). Measurements were carried out in open fields and with an aluminum pole of 4 mm diameter as a central block. The geometric volume effect was calculated from profiles obtained with Gafchromic EBT3 film, evaluated using FilmQA Pro software (Ashland, USA). Results: Volume corrections were 1.7% at maximum. After correction, in small open fields, unshielded diodes showed a lower response than the diamond, i.e. diamond detector over-response seems to be higher than that for unshielded diodes. Beneath the block, this behavior was amplified by a factor of 2. For the shielded diodes, the overresponse for small open fields could be confirmed. However their lateral response behavior was strongly type dependent, e.g. the signal ratio dropped from 1.02 to 0.98 for the P-60008 diode. Conclusion: The lateral detector response was experimentally examined. Detector volume and density alone do not fully account for the field size dependence of detector response. Detector construction details play a major role, especially for shielded diodes.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20050244823','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20050244823"><span>Characterization of High-power Quasi-cw Laser Diode Arrays</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Stephen, Mark A.; Vasilyev, Aleksey; Troupaki, Elisavet; Allan, Graham R.; Kashem, Nasir B.</p> <p>2005-01-01</p> <p>NASA s requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance and comprehensive characterization data of Quasi-CW, High-power, laser diode arrays is presented.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20050223559','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20050223559"><span>Improving Reliability of High Power Quasi-CW Laser Diode Arrays for Pumping Solid State Lasers</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Baggott, Renee S.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.</p> <p>2005-01-01</p> <p>Most Lidar applications rely on moderate to high power solid state lasers to generate the required transmitted pulses. However, the reliability of solid state lasers, which can operate autonomously over long periods, is constrained by their laser diode pump arrays. Thermal cycling of the active regions is considered the primary reason for rapid degradation of the quasi-CW high power laser diode arrays, and the excessive temperature rise is the leading suspect in premature failure. The thermal issues of laser diode arrays are even more drastic for 2-micron solid state lasers which require considerably longer pump pulses compared to the more commonly used pump arrays for 1-micron lasers. This paper describes several advanced packaging techniques being employed for more efficient heat removal from the active regions of the laser diode bars. Experimental results for several high power laser diode array devices will be reported and their performance when operated at long pulsewidths of about 1msec will be described.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1082127','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/1082127"><span>V-shaped resonators for addition of broad-area laser diode arrays</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Liu, Bo; Liu, Yun; Braiman, Yehuda Y.</p> <p>2012-12-25</p> <p>A system and method for addition of broad-area semiconductor laser diode arrays are described. The system can include an array of laser diodes, a V-shaped external cavity, and grating systems to provide feedback for phase-locking of the laser diode array. A V-shaped mirror used to couple the laser diode emissions along two optical paths can be a V-shaped prism mirror, a V-shaped stepped mirror or include multiple V-shaped micro-mirrors. The V-shaped external cavity can be a ring cavity. The system can include an external injection laser to further improve coherence and phase-locking.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_23 --> <div id="page_24" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="461"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1228728','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1228728"><span>Stacked, Filtered Multi-Channel X-Ray Diode Array</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>MacNeil, Lawrence P.; Dutra, Eric C.; Raphaelian, Mark</p> <p>2015-08-01</p> <p>This system meets the need for a low-cost, robust X-ray diode array to use for experiments in hostile environments on multiple platforms, and for experiments utilizing forces that may destroy the diode(s). Since these uses require a small size with a minimal single line-of-sight, a parallel array often cannot be used. So a stacked, filtered multi-channel X-ray diode array was developed that was called the MiniXRD. The design was modeled, built, and tested at National Security Technologies, LLC (NSTec) Livermore Operations (LO) to determine fundamental characteristics. Then, several different systems were fielded as ancillary “ridealong” diagnostics at several national facilitiesmore » to allow us to iteratively improve the design and usability. Presented here are design considerations and experimental results. This filtered diode array is currently at Technical Readiness Level (TRL) 6.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=19920041397&hterms=tunnel+diodes&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D60%26Ntt%3Dtunnel%2Bdiodes','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=19920041397&hterms=tunnel+diodes&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D60%26Ntt%3Dtunnel%2Bdiodes"><span>Characterization of resonant tunneling diodes for microwave and millimeter-wave detection</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Mehdi, I.; East, J. R.; Haddad, G. I.</p> <p>1991-01-01</p> <p>The authors report on the direct detection capabilities of resonant tunneling diodes in the 10-100 GHz range. An open circuit voltage sensitivity of 1750 mV/mW (in Ka-band) was measured. This is higher than the sensitivity of comparatively based commercially available solid-state detectors. The detector properties are a strong function of diode bias and the measured tangential signal sensitivity (-32 dBm at Ka-band with 1-MHz bandwidth) and the dynamic range (25 dB) of the diode are smaller compared to other solid-state detectors.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/22098730-dosimetric-performance-array-assessment-plastic-scintillation-detectors-stereotactic-radiosurgery-quality-assurance','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/22098730-dosimetric-performance-array-assessment-plastic-scintillation-detectors-stereotactic-radiosurgery-quality-assurance"><span></span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu</p> <p></p> <p>Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured.more » The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore, volume averaging of the IC can be observed for the 5 mm aperture where it differs by as much as 9.1% compared to the PSD measurement. The angular dependency of the UD is also observed, unveiled by an under-response around 2.5% of both 5 and 35 mm apertures. Conclusions: Output Factors and dose profiles measurements performed, respectively, with the PSD and the PSDCA were in agreement with those obtained with the UD and EBT2 films. For stereotactic radiosurgery treatment verification, the PSD gives accurate results compared to the planning system and the IC once the latter is corrected to compensate for the averaging effect of the IC. The PSD provides precise results when used as a single detector or in a dense array, resulting in a great potential for stereotactic radiosurgery QA measurements.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/10497926','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/10497926"><span>Separation and identification of various carotenoids by C30 reversed-phase high-performance liquid chromatography coupled to UV and atmospheric pressure chemical ionization mass spectrometric detection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Lacker, T; Strohschein, S; Albert, K</p> <p>1999-08-27</p> <p>In this paper the application of on-line HPLC-UV-APCI (atmospheric pressure chemical ionization) mass spectrometry (MS) coupling for the separation and determination of different carotenoids as well as cis/trans isomers of beta-carotene is reported. All HPLC separations were carried out under RP conditions on self-synthesized polymeric C30 phases. The analysis of a carotenoid mixture containing astaxanthin, canthaxanthin, zeaxanthin, echinenone and beta-carotene by HPLC-APCI-MS was achieved by scanning the mass range from m/z 200 to 700. For the characterization of a sample containing cis/trans isomers of beta-carotene as well as their oxidation products, a photodiode-array UV-visible absorbance detector was used in addition between the column and the mass spectrometer for structural elucidation of the geometrical isomers. The detection limit for beta-carotene in positive-ion APCI-MS was determined to be 1 pmol. In addition, an extract of non-polar substances in vegetable juice has been analyzed by HPLC-APCI-MS. The included carotenoids could be identified by their masses and their retention times.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21261251','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21261251"><span>Identification of proanthocyanidin dimers and trimers, flavone C-Glycosides, and antioxidants in Ficus deltoidea , a malaysian herbal tea.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Omar, Maizatul Hasyima; Mullen, William; Crozier, Alan</p> <p>2011-02-23</p> <p>Phenolic compounds in an aqueous infusion of leaves of Ficus deltoidea (Moraceae), a well-known herbal tea in Malaysia, were analyzed by HPLC coupled to photodiode array and fluorescence detectors and an electrospray ionization tandem mass spectrometer. Following chromatography of extracts on a reversed phase C(12) column, 25 flavonoids were characterized and/or tentatively identified with the main constituents being flavan-3-ol monomers, proanthocyanidins, and C-linked flavone glycosides. The proanthocyanidins were dimers and trimers comprising (epi)catechin and (epi)afzelechin units. No higher molecular weight proanthocyanidin polymers were detected. The antioxidant activity of F. deltoidea extract was analyzed using HPLC with online antioxidant detection. This revealed that 85% of the total antioxidant activity of the aqueous F. deltoidea infusion was attributable to the flavan-3-ol monomers and the proanthocyanidins.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22385160','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22385160"><span>High-yield transfer printing of metal-insulator-metal nanodiodes.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Bareiss, Mario; Ante, Frederik; Kälblein, Daniel; Jegert, Gunther; Jirauschek, Christian; Scarpa, Giuseppe; Fabel, Bernhard; Nelson, Edward M; Timp, Gregory; Zschieschang, Ute; Klauk, Hagen; Porod, Wolfgang; Lugli, Paolo</p> <p>2012-03-27</p> <p>Nanoscale metal-insulator-metal (MIM) diodes represent important devices in the fields of electronic circuits, detectors, communication, and energy, as their cutoff frequencies may extend into the "gap" between the electronic microwave range and the optical long-wave infrared regime. In this paper, we present a nanotransfer printing method, which allows the efficient and simultaneous fabrication of large-scale arrays of MIM nanodiode stacks, thus offering the possibility of low-cost mass production. In previous work, we have demonstrated the successful transfer and electrical characterization of macroscopic structures. Here, we demonstrate for the first time the fabrication of several millions of nanoscale diodes with a single transfer-printing step using a temperature-enhanced process. The electrical characterization of individual MIM nanodiodes was performed using a conductive atomic force microscope (AFM) setup. Our analysis shows that the tunneling current is the dominant conduction mechanism, and the electrical measurement data agree well with experimental data on previously fabricated microscale diodes and numerical simulations. © 2012 American Chemical Society</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1174579','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/1174579"><span>Ruggedized microchannel-cooled laser diode array with self-aligned microlens</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Freitas, Barry L.; Skidmore, Jay A.</p> <p>2003-11-11</p> <p>A microchannel-cooled, optically corrected, laser diode array is fabricated by mounting laser diode bars onto Si surfaces. This approach allows for the highest thermal impedance, in a ruggedized, low-cost assembly that includes passive microlens attachment without the need for lens frames. The microlensed laser diode array is usable in all solid-state laser systems that require efficient, directional, narrow bandwidth, high optical power density pump sources.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/18288769','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/18288769"><span>Structural characterization of constituents with molecular diversity in fractions from Lysidice brevicalyx by liquid chromatography/diode-array detection/electrospray ionization tandem mass spectrometry and liquid chromatography/nuclear magnetic resonance.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Qu, Jing; Hu, You-cai; Li, Jian-bei; Wang, Ying-hong; Zhang, Jin-lan; Abliz, Zeper; Yu, Shi-shan; Liu, Yun-bao</p> <p>2008-01-01</p> <p>A combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography (HPLC/ESI-MSn), and hyphenation of liquid chromatography to nuclear magnetic resonance spectroscopy (HPLC/NMR), have been extensively utilized for on-line analysis of natural products, analyzing metabolite and drug impurity. In our last paper, we reported an on-line analytical method for structural identification of trace alkaloids in the same class. However, the structural types of the constituents in plants were various, such as flavanoids, terpenoids and steroids. It is important to establish an effective analytical method for on-line structural identification of constituents with molecular diversity in extracts of plants. So, in the present study, the fragmentation patterns of some isolated stilbenes, phloroglucinols and flavanoids from Lysidice rhodostegia were investigated by ESI-MSn. Their fragmentation rules and UV characteristics are summarized, and the relationship between the spectral characteristics, rules and the structures is described. According to the fragmentation rules, NMR and UV spectral characteristics, 24 constituents of different types in the fractions from L. brevicalyx of the same genus were structurally characterized on the basis of HPLC/HRMS, HPLC-UV/ESI-MSn, HPLC/1H NMR and HPLC/1H-1H COSY rapidly. Of these, six (10, 13, 14, 16, 17 and 23) are new compounds and all of them are reported from L. brevicalyx for the first time. The aim is to develop an effective analytical method for on-line structural identification of natural products with molecular diversity in plants, and to guide the rapid and direct isolation of novel compounds by chemical screening.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20160008885','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20160008885"><span>By-Pass Diode Temperature Tests of a Solar Array Coupon under Space Thermal Environment Conditions</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Wright, Kenneth H.; Schneider, Todd A.; Vaughn, Jason A.; Hoang, Bao; Wong, Frankie; Wu, Gordon</p> <p>2016-01-01</p> <p>By-Pass diodes are a key design feature of solar arrays and system design must be robust against local heating, especially with implementation of larger solar cells. By-Pass diode testing was performed to aid thermal model development for use in future array designs that utilize larger cell sizes that result in higher string currents. Testing was performed on a 56-cell Advanced Triple Junction solar array coupon provided by SSL. Test conditions were vacuum with cold array backside using discrete by-pass diode current steps of 0.25 A ranging from 0 A to 2.0 A.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/20938406','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/20938406"><span>Evaluation of antioxidant capacity and synergistic associations of quinonemethide triterpenes and phenolic substances from Maytenus ilicifolia (Celastraceae).</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Dos Santos, Vânia Aparecida de Freitas Formenton Macedo; Dos Santos, Daniela Pereira; Castro-Gamboa, Ian; Zanoni, Maria Valnice Boldrin; Furlan, Maysa</p> <p>2010-10-11</p> <p>This work describes the isolation of the secondary metabolites identified as the quinonemethides maytenin (1) and pristimerin (2) from Maytenus ilicifolia extracts obtained from root barks of adult plants and roots of seedlings and their quantification by high performance liquid chromatography coupled to a diode array detector. The electrochemical profiles obtained from cyclic voltammetry and a coulometric detector coupled to high-performance liquid chromatography contributed to the evaluation of their antioxidant capacity. The antioxidant properties of individual components and the crude extracts of the root barks of Maytenus ilicifolia were compared and the possible synergistic associations of quinonemethide triterpenes and phenolic substances were investigated by using rutin as a model phenolic compound.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27706530','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27706530"><span>Antiviral Activity of Crude Hydroethanolic Extract from Schinus terebinthifolia against Herpes simplex Virus Type 1.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Nocchi, Samara Requena; Companhoni, Mychelle Vianna Pereira; de Mello, João Carlos Palazzo; Dias Filho, Benedito Prado; Nakamura, Celso Vataru; Carollo, Carlos Alexandre; Silva, Denise Brentan; Ueda-Nakamura, Tânia</p> <p>2017-04-01</p> <p>Herpes simplex virus infections persist throughout the lifetime of the host and affect more than 80 % of the humans worldwide. The intensive use of available therapeutic drugs has led to undesirable effects, such as drug-resistant strains, prompting the search for new antiherpetic agents. Although diverse bioactivities have been identified in Schinus terebinthifolia , its antiviral activity has not attracted much attention. The present study evaluated the antiherpetic effects of a crude hydroethanolic extract from the stem bark of S. terebinthifolia against Herpes simplex virus type 1 in vitro and in vivo as well as its genotoxicity in bone marrow in mammals and established the chemical composition of the crude hydroethanolic extract based on liquid chromatography-diode array detector-mass spectrometry and MS/MS. The crude hydroethanolic extract inhibited all of the tested Herpes simplex virus type 1 strains in vitro and was effective in the attachment and penetration stages, and showed virucidal activity, which was confirmed by transmission electron microscopy. The micronucleus test showed that the crude hydroethanolic extract had no genotoxic effect at the concentrations tested. The crude hydroethanolic extract afforded protection against lesions that were caused by Herpes simplex virus type 1 in vivo . Liquid chromatography-diode array detector-mass spectrometry and MS/MS identified 25 substances, which are condensed tannins mainly produced by a B-type linkage and prodelphinidin and procyanidin units. Georg Thieme Verlag KG Stuttgart · New York.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018SPIE10539E..0BC','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018SPIE10539E..0BC"><span>Highly efficient router-based readout algorithm for single-photon-avalanche-diode imagers for time-correlated experiments</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Cominelli, A.; Acconcia, G.; Caldi, F.; Peronio, P.; Ghioni, M.; Rech, I.</p> <p>2018-02-01</p> <p>Time-Correlated Single Photon Counting (TCSPC) is a powerful tool that permits to record extremely fast optical signals with a precision down to few picoseconds. On the other hand, it is recognized as a relatively slow technique, especially when a large time-resolved image is acquired exploiting a single acquisition channel and a scanning system. During the last years, much effort has been made towards the parallelization of many acquisition and conversion chains. In particular, the exploitation of Single-Photon Avalanche Diodes in standard CMOS technology has paved the way to the integration of thousands of independent channels on the same chip. Unfortunately, the presence of a large number of detectors can give rise to a huge rate of events, which can easily lead to the saturation of the transfer rate toward the elaboration unit. As a result, a smart readout approach is needed to guarantee an efficient exploitation of the limited transfer bandwidth. We recently introduced a novel readout architecture, aimed at maximizing the counting efficiency of the system in typical TCSPC measurements. It features a limited number of high-performance converters, which are shared with a much larger array, while a smart routing logic provides a dynamic multiplexing between the two parts. Here we propose a novel routing algorithm, which exploits standard digital gates distributed among a large 32x32 array to ensure a dynamic connection between detectors and external time-measurement circuits.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2014AIPC.1639..142R','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2014AIPC.1639..142R"><span>Diagnostics for Z-pinch implosion experiments on PTS</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Ren, X. D.; Huang, X. B.; Zhou, S. T.; Zhang, S. Q.; Dan, J. K.; Li, J.; Cai, H. C.; Wang, K. L.; Ouyang, K.; Xu, Q.; Duan, S. C.; Chen, G. H.; Wang, M.; Feng, S. P.; Yang, L. B.; Xie, W. P.; Deng, J. J.</p> <p>2014-12-01</p> <p>The preliminary experiments of wire array implosion were performed on PTS, a 10 MA z-pinch driver with a 70 ns rise time. A set of diagnostics have been developed and fielded on PTS to study pinch physics and implosion dynamics of wire array. Radiated power measurement for soft x-rays was performed by multichannel filtered x-ray diode array, and flat spectral responses x-ray diode detector. Total x-ray yield was measured by a calibrated, unfiltered nickel bolometer which was also used to obtain pinch power. Multiple time-gated pinhole cameras were used to produce spatial-resolved images of x-ray self-emission from plasmas. Two time-integrated pinhole cameras were used respectively with 20-μm Be filter and with multilayer mirrors to record images produced by >1-keV and 277±5 eV self-emission. An optical streak camera was used to produce radial implosion trajectories, and an x-ray streak camera paired with a horizontal slit was used to record a continuous time-history of emission with one-dimensional spatial resolution. A frequency-doubled Nd:YAG laser (532 nm) was used to produce four frame laser shadowgraph images with 6 ns time interval. We will briefly describe each of these diagnostics and present some typical results from them.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5726170','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5726170"><span>Entrance dose measurements for in‐vivo diode dosimetry: Comparison of correction factors for two types of commercial silicon diode detectors</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Zhu, X. R.</p> <p>2000-01-01</p> <p>Silicon diode dosimeters have been used routinely for in‐vivo dosimetry. Despite their popularity, an appropriate implementation of an in‐vivo dosimetry program using diode detectors remains a challenge for clinical physicists. One common approach is to relate the diode readout to the entrance dose, that is, dose to the reference depth of maximum dose such as dmax for the 10×10 cm2 field. Various correction factors are needed in order to properly infer the entrance dose from the diode readout, depending on field sizes, target‐to‐surface distances (TSD), and accessories (such as wedges and compensate filters). In some clinical practices, however, no correction factor is used. In this case, a diode‐dosimeter‐based in‐vivo dosimetry program may not serve the purpose effectively; that is, to provide an overall check of the dosimetry procedure. In this paper, we provide a formula to relate the diode readout to the entrance dose. Correction factors for TSD, field size, and wedges used in this formula are also clearly defined. Two types of commercial diode detectors, ISORAD (n‐type) and the newly available QED (p‐type) (Sun Nuclear Corporation), are studied. We compared correction factors for TSDs, field sizes, and wedges. Our results are consistent with the theory of radiation damage of silicon diodes. Radiation damage has been shown to be more serious for n‐type than for p‐type detectors. In general, both types of diode dosimeters require correction factors depending on beam energy, TSD, field size, and wedge. The magnitudes of corrections for QED (p‐type) diodes are smaller than ISORAD detectors. PACS number(s): 87.66.–a, 87.52.–g PMID:11674824</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2013NIMPA.699..112O','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2013NIMPA.699..112O"><span>Development of signal processing system of avalanche photo diode for space observations by Astro-H</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Ohno, M.; Goto, K.; Hanabata, Y.; Takahashi, H.; Fukazawa, Y.; Yoshino, M.; Saito, T.; Nakamori, T.; Kataoka, J.; Sasano, M.; Torii, S.; Uchiyama, H.; Nakazawa, K.; Watanabe, S.; Kokubun, M.; Ohta, M.; Sato, T.; Takahashi, T.; Tajima, H.</p> <p>2013-01-01</p> <p>Astro-H is the sixth Japanese X-ray space observatory which will be launched in 2014. Two of onboard instruments of Astro-H, Hard X-ray Imager and Soft Gamma-ray Detector are surrounded by many number of large Bismuth Germanate (Bi4Ge3O12; BGO) scintillators. Optimum readout system of scintillation lights from these BGOs are essential to reduce the background signals and achieve high performance for main detectors because most of gamma-rays from out of field-of-view of main detectors or radio-isotopes produced inside them due to activation can be eliminated by anti-coincidence technique using BGO signals. We apply Avalanche Photo Diode (APD) for light sensor of these BGO detectors since their compactness and high quantum efficiency make it easy to design such large number of BGO detector system. For signal processing from APDs, digital filter and other trigger logics on the Field-Programmable Gate Array (FPGA) is used instead of discrete analog circuits due to limitation of circuit implementation area on spacecraft. For efficient observations, we have to achieve as low threshold of anti-coincidence signal as possible by utilizing the digital filtering. In addition, such anti-coincident signals should be sent to the main detector within 5 μs to make it in time to veto the A-D conversion. Considering this requirement and constraint from logic size of FPGA, we adopt two types of filter, 8 delay taps filter with only 2 bit precision coefficient and 16 delay taps filter with 8 bit precision coefficient. The data after former simple filter provides anti-coincidence signal quickly in orbit, and the latter filter is used for detail analysis after the data is down-linked.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2008SPIE.7119E..0HT','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2008SPIE.7119E..0HT"><span>Development of a portable thermal neutron detector based on a boron rich heterodiode</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Tomov, R.; Venn, R.; Owens, A.; Peacock, A.</p> <p>2008-10-01</p> <p>Results are presented on the development of a portable detector suitable for detection of individual thermal neutrons. The device is based on direct absorption of neutrons in an absorber film containing 10B. The resultant charge arising from the capture products is detected by a p-n junction partly formed from this absorber and internal to the device. When a small bias voltage is applied (typically a few volts) a current pulse is observed due to the movement of this charge in the electric field of the p-n junction. For each detected neutron the charge pulse height, rise time and time of detection are recorded. Device performance, in terms of efficiency and spectral response, is explored as a function of neutron absorber thickness, geometry and overall diode electrical characteristics and validated against neutron source measurements at the UK National Physical Laboratory (NPL). The diodes have a natural background suppression capability through traditional pulse height and pulse rise time discrimination. The manufacturing process permits fabrication of arrays of diodes, with typical areas of ~15 mm2, thus increasing the collecting area and the signal to noise ratio, albeit with increased readout complexity. The associated multi-channel readout electronics is standard, however, and commonly used in existing X-ray sensors. Simple portable sensors based on these heterodiodes are expected to have applications in the detection of nuclear materials in a variety of security related situations.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017JInst..12C1006S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017JInst..12C1006S"><span>A sub-millimeter resolution detector module for small-animal PET applications</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Sacco, I.; Dohle, R.; Fischer, P.; Gola, A.; Piemonte, C.; Ritzert, M.</p> <p>2017-01-01</p> <p>We present a gamma detection module optimized for very high resolution PET applications, able to resolve arrays of scintillating crystals with sub-millimeter pitch. The detector is composed of a single ceramic substrate (LTCC): it hosts four flip-chip mounted PETA5 ASICs on the bottom side and an array of SiPM sensors on the top surface, fabricated in HD-RGB technology by FBK. Each chip has 36 channels, for a maximum of 144 readout channels on a sensitive area of about 32 mm × 32 mm. The module is MR-compatible. The thermal decoupling of the readout electronics from the photon sensors is obtained with an efficient internal liquid channel, integrated within the ceramic substrate. Two modules have been designed, based on different SiPM topologies: • Light spreader-based: an array of 12 × 12 SiPMs, with an overall pitch of 2.5 mm, is coupled with a scintillators array using a 1 mm thick glass plate. The light from one crystal is spread over a group of SiPMs, which are read out in parallel using PETA5 internal neighbor logic. • Interpolating SiPM-based: ISiPMs are intrinsic position-sensitive sensors. The photon diodes in the array are connected to one of the four available outputs so that the center of gravity of any bunch of detected photons can be reconstructed using a proper weight function of the read out amplitudes. An array of ISiPMs, each 7.5 mm× 5 mm sized, is directly coupled with the scintillating crystals. Both modules can clearly resolve LYSO arrays with a pitch of only 0.833 mm. The detector can be adjusted for clinical PET, where it has already shown ToF resolution of about 230 ps CRT at FWHM. The module designs, their features and results are described.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27194521','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27194521"><span>Characterization of chemical constituents in Rhodiola Crenulate by high-performance liquid chromatography coupled with Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS).</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Han, Fei; Li, Yanting; Mao, Xinjuan; Xu, Rui; Yin, Ran</p> <p>2016-05-01</p> <p>In this work, an approach using high-performance liquid chromatography coupled with diode-array detection and Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS) for the identification and profiling of chemical constituents in Rhodiola crenulata was developed for the first time. The chromatographic separation was achieved on an Inertsil ODS-3 column (150 mm × 4.6 mm,3 µm) using a gradient elution program, and the detection was performed on a Bruker Solarix 7.0 T mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 48 chemical compounds, including 26 alcohols and their glycosides, 12 flavonoids and their glycosides, 5 flavanols and gallic acid derivatives, 4 organic acids and 1 cyanogenic glycoside were identified or tentatively characterized. The results indicated that the developed HPLC-FT-ICR MS method with ultra-high sensitivity and resolution is suitable for identifying and characterizing the chemical constituents in R. crenulata. And it provides a helpful chemical basis for further research on R. crenulata. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4665423','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4665423"><span>HPLC-DAD Phenolic Characterization and Antioxidant Activities of Ripe and Unripe Sweet Orange Peels</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Omoba, Olufunmilayo Sade; Obafaye, Rebeccah Olajumoke; Salawu, Sule Ola; Boligon, Aline Augusti; Athayde, Margareth Linde</p> <p>2015-01-01</p> <p>Phenolic compounds of unripe and ripe sweet orange peels were determined using a high-performance liquid chromatography separation method with diode array detector (HPLC-DAD). The in vitro antioxidant properties and the EC50 (concentration required to obtain a 50% antioxidant effect) values were also determined. The predominant phenolic compounds were quercitrin, rutin, and quercetin with values of 18.77 ± 0.01 mg/mL, 18.65 ± 0.03 mg/mL, and 10.39 ± 0.01 mg/mL respectively in unripe orange peel and 22.61 ± 0.01 mg/mL, 17.93 ± 0.03 mg/mL, and 14.03 ± 0.02 mg/mL respectively in ripe orange peel. The antioxidant properties revealed 2,2′-azino-bis(3-ethyl benzothiazoline-6-sulfonic acid) diammonium salt (ABTS) scavenging ability of both unripe and ripe orange peels respectively as 14.68 ± 0.01 and 16.89 ± 0.02 mmol TEAC/g, the Ferric Reducing Antioxidant Properties (FRAP) as 70.69 ± 0.01 and 91.38 ± 0.01 mg gallic acid equivalents/100g, total phenol content as 5.27 ± 0.03 and 9.40 ± 0.01 mg gallic acid equivalents/g and total flavonoid content as 3.30 ± 0.30 and 4.20 ± 0.02 mg quercetin equivalent/g. The antioxidant assays showed enhanced potency of extract from ripe orange peel with EC50 values of 2.71 ± 0.03 mg/mL for 2,2-diphenyl-1-picrylhydrazyl (DPPH), 0.67 ± 0.03 mg/mL for hydroxyl radicals (OH*), 0.57 ± 0.02 mg/mL for Fe2+ chelation, and 0.63 ± 0.06 mg/mL for malondialdehyde (MDA), and was more potent than unripe orange peel. PMID:26783839</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25793599','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25793599"><span>Monitoring and evaluating the quality consistency of Compound Bismuth Aluminate tablets by a simple quantified ratio fingerprint method combined with simultaneous determination of five compounds and correlated with antioxidant activities.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Liu, Yingchun; Liu, Zhongbo; Sun, Guoxiang; Wang, Yan; Ling, Junhong; Gao, Jiayue; Huang, Jiahao</p> <p>2015-01-01</p> <p>A combination method of multi-wavelength fingerprinting and multi-component quantification by high performance liquid chromatography (HPLC) coupled with diode array detector (DAD) was developed and validated to monitor and evaluate the quality consistency of herbal medicines (HM) in the classical preparation Compound Bismuth Aluminate tablets (CBAT). The validation results demonstrated that our method met the requirements of fingerprint analysis and quantification analysis with suitable linearity, precision, accuracy, limits of detection (LOD) and limits of quantification (LOQ). In the fingerprint assessments, rather than using conventional qualitative "Similarity" as a criterion, the simple quantified ratio fingerprint method (SQRFM) was recommended, which has an important quantified fingerprint advantage over the "Similarity" approach. SQRFM qualitatively and quantitatively offers the scientific criteria for traditional Chinese medicines (TCM)/HM quality pyramid and warning gate in terms of three parameters. In order to combine the comprehensive characterization of multi-wavelength fingerprints, an integrated fingerprint assessment strategy based on information entropy was set up involving a super-information characteristic digitized parameter of fingerprints, which reveals the total entropy value and absolute information amount about the fingerprints and, thus, offers an excellent method for fingerprint integration. The correlation results between quantified fingerprints and quantitative determination of 5 marker compounds, including glycyrrhizic acid (GLY), liquiritin (LQ), isoliquiritigenin (ILG), isoliquiritin (ILQ) and isoliquiritin apioside (ILA), indicated that multi-component quantification could be replaced by quantified fingerprints. The Fenton reaction was employed to determine the antioxidant activities of CBAT samples in vitro, and they were correlated with HPLC fingerprint components using the partial least squares regression (PLSR) method. In summary, the method of multi-wavelength fingerprints combined with antioxidant activities has been proved to be a feasible and scientific procedure for monitoring and evaluating the quality consistency of CBAT.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_24 --> <div id="page_25" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="481"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21907994','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21907994"><span>Isolation and identification of phenolic compounds from rum aged in oak barrels by high-speed countercurrent chromatography/high-performance liquid chromatography-diode array detection-electrospray ionization mass spectrometry and screening for antioxidant activity.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Regalado, Erik L; Tolle, Sebastian; Pino, Jorge A; Winterhalter, Peter; Menendez, Roberto; Morales, Ana R; Rodríguez, José L</p> <p>2011-10-14</p> <p>Beverages, especially wines are well-known to contain a variety of health-beneficial bioactive substances, mainly of phenolic nature which frequently exhibit antioxidant activity. Significant information is available about the separation and identification of polyphenols from some beverages by chromatographic and spectroscopic techniques, but considerably poor is chemical data related to the polyphenolic content in rums. In this paper, a method involving the all-liquid chromatographic technique of high-speed countercurrent chromatography (HSCCC) combined with high-performance liquid chromatography coupled with diode-array detection and electrospray ionization mass spectrometry (HPLC-DAD-ESI-MS(n)) has been successfully applied for separation and identification of phenolic compounds in an aged rum. Besides, the phenolic fraction (PF) was assayed for its antioxidant effects using three different free radical in vitro assays (DPPH·, RO(2)· and spontaneous lipid peroxidation (LPO) on brain homogenates) and on ferric reducing antioxidant power (FRAP). Results showed that PF potently scavenged DPPH and strongly scavenged peroxyl radicals compared to ascorbic acid and butylated hydroxytoluene (BHT); and almost equally inhibited LPO on brain homogenates subjected to spontaneous LPO when compared to quercetin. Moreover, PF also exhibited strong reducing power. This chemical analysis illustrates the rich array of phenols in the aged rum and represents a rapid and suitable method for the isolation and identification of phenolic compounds from mixtures of considerable complexity, achieving high purity and reproducibility with the use of two separation steps. Copyright © 2011 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5669071','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5669071"><span>Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari</p> <p>2017-01-01</p> <p>Background: Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. Objective: To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O-phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. Materials and Methods: OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C18 column. Results: The HPLC–DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. Conclusion: All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. SUMMARY The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and quantification of 17 free amino acids in Orthosiphon stamineus (OS) Benth extractsOS extracts were found to be rich in free amino acid contentL-aspartic acid was the major free amino acid in OS water extract while, in OS ethanol, methanol, 50% ethanol and 50% methanol extracts, L-glutamic acid was the major free amino acidL-serine was the minor free amino acid in OS water, ethanol and methanol extracts while, in OS 50% ethanol and 50% methanol extracts, L-threonine had the lowest concentration compared to other amino acid components. Abbreviations used: HPLC-DAD: High-Performance Liquid Chromatography with Diode-Array Detection, OS: Orthosiphon stamineus, OS-W: Orthosiphon stamineus water extract, OS-E: Orthosiphon stamineus ethanol extract, OS-M: Orthosiphon stamineus methanol extract, OS-EW: Orthosiphon stamineus 50% ethanol extract, OS-MW: Orthosiphon stamineus 50% methanol extract, OPA: O-phthaladehyde, SPE: Solid Phase Extraction, UV: Ultraviolet, LOD: Limit of Detection, LOQ: Limit of Quantification, RSD: Relative Standard Deviation. PMID:29142388</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/18381701','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/18381701"><span>Enantioselective HPLC resolution of synthetic intermediates of armodafinil and related substances.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Nageswara Rao, Ramisetti; Shinde, Dhananjay D; Kumar Talluri, Murali V N</p> <p>2008-04-01</p> <p>Armodafinil is a unique psychostimulant recently approved by the US Food and Drug Administration for the treatment of narcolepsy. The chromatographic resolution of its chiral intermediates including related substances in the total synthesis of armodafinil was studied on polysaccharide-based stationary phases, viz. cellulose tris-(3,5-dimethylphenylcarbamate) (Chiralcel OD-H) and amylose tris-(3,5-dimethylphenylcarbamate) (Chiralpak AD-H) by HPLC. The effects of 1-propanol, 2-propanol, ethanol, and trifluoroacetic acid added to the mobile phase and of column temperature on resolution were studied. A good separation was achieved on cellulose-based Chiralcel OD-H column compared to amylose-based Chiralpak AD-H. The effects of structural features of the solutes and solvents on discrimination between the enantiomers were examined. Baseline separation with R(s) >1.38 was obtained using a mobile phase containing n-hexane-ethanol-TFA (75:25:0.15 v/v/v). Detection was carried out at 225 nm with photodiode array detector while identification of enantiomers was accomplished by a polarimetric detector connected in series. The method was found to be suitable not only for process development of armodafinil but also for determination of the enantiomeric purity of bulk drugs and pharmaceuticals.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20120000776','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20120000776"><span>Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Chattopadhyay, Goutam; Gill, John J.; Skalare, Anders; Lee, Choonsup; Llombart, Nuria; Siegel, Peter H.</p> <p>2011-01-01</p> <p>Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/868245','DOE-PATENT-XML'); return false;" href="https://www.osti.gov/servlets/purl/868245"><span>Modular package for cooling a laser diode array</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/doepatents">DOEpatents</a></p> <p>Mundinger, David C.; Benett, William J.; Beach, Raymond J.</p> <p>1992-01-01</p> <p>A laser diode array is disclosed that includes a plurality of planar packages and active cooling. The laser diode array may be operated in a long duty cycle, or in continuous operation. A laser diode bar and a microchannel heat sink are thermally coupled in a compact, thin planar package having the laser diode bar located proximate to one edge. In an array, a number of such thin planar packages are secured together in a stacked configuration, in close proximity so that the laser diodes are spaced closely. The cooling means includes a microchannel heat sink that is attached proximate to the laser bar so that it absorbs heat generated by laser operation. To provide the coolant to the microchannels, each thin planar package comprises a thin inlet manifold and a thin outlet manifold connected to an inlet corridor and an outlet corridor. The inlet corridor comprises a hole extending through each of the packages in the array, and the outlet corridor comprises a hole extending through each of the packages in the array. The inlet and outlet corridors are connected to a conventional coolant circulation system. The laser diode array with active cooling has application as an optical pump for high power solid state lasers. Further, it can be incorporated in equipment such as communications devices and active sensors, and in military and space applications, and it can be useful in applications having space constraints and energy limitations.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27734585','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27734585"><span>Ultrafiltration-LC-MS combined with semi-preparative HPLC for the simultaneous screening and isolation of lactate dehydrogenase inhibitors from Belamcanda chinensis.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Li, Senlin; Li, Sainan; Tang, Ying; Liu, Chunming; Chen, Lina; Zhang, Yuchi</p> <p>2016-12-01</p> <p>Stroke represents the fourth leading cause of death in the USA and the second leading cause of death worldwide. Lactate dehydrogenase inhibitors are widely used in the treatment of ischemic stroke and natural products are considered a promising source of novel lactate dehydrogenase inhibitors. In this study, we used PC12 cells to determine the protective effect of extracts from the herb Belamcanda chinensis following toxic challenge. Using ultrafiltration high-performance liquid chromatography coupled with photo-diode array detection and electrospray ionization mass spectrometry, we screened and identified isoflavonoids from Belamcanda chinensis extracts. Semi-preparative high-performance liquid chromatography was then applied to separate and isolate the active constituents. Using these methods, we identified six major compounds in Belamcanda chinensis as lactate dehydrogenase inhibitors: tectoridin, iristectorin A, iridin, tectorigenin, irigenin, and irisflorentin, which were then isolated to >92% purity. This is the first report that Belamcanda chinensis extracts contain potent lactate dehydrogenase inhibitors. Our results demonstrate that the systematic isolation of bioactive components from Belamcanda chinensis guided by ultrafiltration high-performance liquid chromatography coupled with photo-diode array detection and electrospray ionization mass spectrometry represents a feasible and efficient technique that could be extended for the identification and isolation of other enzyme inhibitors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/16929841','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/16929841"><span>[Simultaneous determination of four compounds in Sanjing Shuanghuanglian Oral Liquid by high performance liquid chromatography-diode array detection-electrochemical detection].</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Liu, Lin; Suo, Zhirong; Zheng, Jianbin</p> <p>2006-05-01</p> <p>Chlorogenic acid, caffeic acid, baicalin and luteolin in Sanjing Shuanghuanglian Oral Liquid were simultaneously detected and identified using a high performance liquid chromatography coupled with diode array detection and electrochemical detection (HPLC-DAD-ECD). The separation was performed on a Zorbax SB-C18 column (150 mm x 4.6 mm i. d., 5.0 microm). The mobile phase consisted of (A) methanol and (B) methanol-water-acetic acid (50: 50: 1, v/v/v) using a linear gradient elution of 2%A-3%A at 0-3 min, 3%A-25%A at 3-15 min, 25%A-80%A at 15-20 min. The flow rate was 0.8 mL/min. The DAD detection was used at 275 nm. The ECD detection was done at 0.7 V. The column thermostat set at 30 degrees C. The limits of detection of the 4 compounds were 1 mg/L for chlorogenic acid, 0.2 mg/L for caffeic acid, 9 mg/L for baicalin, 7 mg/L for luteolin. The average recoveries were between 96.6%-99.6% with relative standard deviations (RSDs) of 2.5%-4.1%. The method is simple, rapid, reproducible and accurate. It can be used for the routine analysis of the four compounds in Shuanghuanglian Oral Liquid.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27005409','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27005409"><span>Sensitive determination of three aconitum alkaloids and their metabolites in human plasma by matrix solid-phase dispersion with vortex-assisted dispersive liquid-liquid microextraction and HPLC with diode array detection.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri</p> <p>2016-05-01</p> <p>A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27710890','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27710890"><span>Development and validation of reverse phase high performance liquid chromatography for citral analysis from essential oils.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Gaonkar, Roopa; Yallappa, S; Dhananjaya, B L; Hegde, Gurumurthy</p> <p>2016-11-15</p> <p>Citral is a widely used monoterpene aldehyde in aromatherapy, food and pesticide industries. A new validated reverse phase high performance liquid chromatography (RP - HPLC) procedure for the detection and quantification of cis-trans isomers of citral was developed. The RP-HPLC analysis was carried out using Enable C - 18G column (250×4.6mm, 5μ), with acetonitrile and water (70: 30) mobile phase in isocratic mode at 1mL/min flow. A photodiode array (PDA) detector was set at 233nm for the detection of citral. The method showed linearity, selectivity and accuracy for citral in the range of 3-100μg/mL. In order to compare the new RP-HPLC method with the available methods, one of the commercially available essential oil from Cymbopogon flexuosus was analyzed using new RP-HPLC method and the same was analyzed using GC-MS for the comparison of the method for the detection of citral. The GC-MS analysis was done using mass selective detector (MSD) showed citral content to be of 72.76%; wherein the new method showed to contain that same at 74.98%. To prove the application of the new method, essential oils were extracted from lemongrass, lemon leaves and mosambi peels by steam distillation. The citral content present in the essential and also in the condensate was analyzed. The method was found to be suitable for the analysis of citral in essential oils and water based citral formulations with a very good resolution of its components geranial and neral. Copyright © 2016 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=19860030593&hterms=solar+tracker&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D40%26Ntt%3Dsolar%2Btracker','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=19860030593&hterms=solar+tracker&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D40%26Ntt%3Dsolar%2Btracker"><span>Retroreflector field tracker. [noncontact optical position sensor for space application</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Wargocki, F. E.; Ray, A. J.; Hall, G. E.</p> <p>1984-01-01</p> <p>An electrooptical position-measuring instrument, the Retroreflector Field Tracker or RFT, is described. It is part of the Dynamic Augmentation Experiment - a part of the payload of Space Shuttle flight 41-D in Summer 1984. The tracker measures and outputs the position of 23 reflective targets placed on a 32-m solar array to provide data for determination of the dynamics of the lightweight structure. The sensor uses a 256 x 256 pixel CID detector; the processor electronics include three Z-80 microprocessors. A pulsed laser diode illuminator is used.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://www.dtic.mil/docs/citations/ADA567752','DTIC-ST'); return false;" href="http://www.dtic.mil/docs/citations/ADA567752"><span>Optimization and Validation of a Surface Wipe Method to Determine Cyanide and Cyanate: Application to the Emergency Destruction System</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.dtic.mil/">DTIC Science & Technology</a></p> <p></p> <p>2012-08-01</p> <p>NJ b WC-7 Grade 42, 55 mm filter paper Whatman, Piscataway, NJ b WC-8 Cellulose nitrate membrane filter, 47 mm Whatman, Piscataway, NJ b WC-9...density polypropylene plastic bottle. 2.5 Standards Sodium cyanide (NaCN, ≥97.0%, CAS no. 143-33-9) and potassium cyanate (KOCN, ≥97.0...Agilent Technologies model 3D CE system, with an ultraviolet (deuterium lamp) diode array detector, was used to determine the quantities of CN and OCN</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22772833','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22772833"><span>Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin</p> <p>2012-10-01</p> <p>An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/18969849','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/18969849"><span>A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca</p> <p>2005-02-15</p> <p>A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23265494','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23265494"><span>UPLC and HPLC of caffeoyl esters in wild and cultivated Arctium lappa L.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Haghi, Ghasem; Hatami, Alireza; Mehran, Mehdi</p> <p>2013-05-01</p> <p>Analytical methods including ultra-performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) with photodiode array (PDA) detector were developed for the analysis of caffeoylquinic acid derivatives in seeds, leaves and roots of Arctium lappa L. Separation was performed on C(18) column utilising 5% (v/v) acetic acid in water and acetonitrile at 330 nm. Both methodologies were validated in terms of linearity, precision, and recovery. The results showed that the major advantages of UPLC, over HPLC were the fast analysis, narrow peaks, high sensitivity, and reduction of solvent consumption. Subsequently the methods were applied for the identification and quantification of chlorogenic acid (5-CQA) and 1,5-dicaffeoylquinic acid (1,5-DCQA) as main compounds in samples. The total phenolic content of samples ranged from 3.93 to 14.13 g of 5-CQA equivalent/100g dry weight (DW). There was a significant variability from 89 to 571 mg/100g for 5-CQA and 48 to 486 mg/100g for 1,5-DCQA in dry material. Copyright © 2012 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016FrMat...3...33F','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016FrMat...3...33F"><span>Advances on Sensitive Electron-injection based Cameras for Low-Flux, Short-Wave-Infrared Applications</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Fathipour, Vala; Bonakdar, Alireza; Mohseni, Hooman</p> <p>2016-08-01</p> <p>Short-wave infrared (SWIR) photon detection has become an essential technology in the modern world. Sensitive SWIR detector arrays with high pixel density, low noise levels and high signal-to-noise-ratios are highly desirable for a variety of applications including biophotonics, light detection and ranging, optical tomography, and astronomical imaging. As such many efforts in infrared detector research are directed towards improving the performance of the photon detectors operating in this wavelength range. We review the history, principle of operation, present status and possible future developments of a sensitive SWIR detector technology, which has demonstrated to be one of the most promising paths to high pixel density focal plane arrays for low flux applications. The so-called electron-injection (EI) detector was demonstrated for the first time (in 2007). It offers an overall system-level sensitivity enhancement compared to the p-i-n diode due to a stable internal avalanche-free gain. The amplification method is inherently low noise, and devices exhibit an excess noise of unity. The detector operates in linear-mode and requires only bias voltage of a few volts. The stable detector characteristics, makes formation of high yield large-format, and high pixel density focal plane arrays less challenging compared to other detector technologies such as avalanche photodetectors. Detector is based on the mature InP material system (InP/InAlAs/GaAsSb/InGaAs), and has a cutoff wavelength of 1700 nm. It takes advantage of a unique three-dimensional geometry and combines the efficiency of a large absorbing volume with the sensitivity of a low-dimensional switch (injector) to sense and amplify signals. Current devices provide high-speed response ~ 5 ns rise time, and low jitter ~ 12 ps at room temperature. The internal dark current density is ~ 1 μA/cm2 at room temperature decreasing to 0.1 nA/cm2 at 160 K. EI detectors have been designed, fabricated, and tested during two generations of development and optimization cycles. We review our imager results using the first-generation detectors. In the second-generation devices, the dark current is reduced by two orders of magnitude, and bandwidth is improved by 4 orders of magnitude. The dark current density of the EI detector is shown to outperform the state-of-the-art technology, the</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29491321','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29491321"><span>Comparison of Peak-area Ratios and Percentage Peak Area Derived from HPLC-evaporative Light Scattering and Refractive Index Detectors for Palm Oil and its Fractions.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ping, Bonnie Tay Yen; Aziz, Haliza Abdul; Idris, Zainab</p> <p>2018-01-01</p> <p>High-Performance Liquid Chromatography (HPLC) methods via evaporative light scattering (ELS) and refractive index (RI) detectors are used by the local palm oil industry to monitor the TAG profiles of palm oil and its fractions. The quantitation method used is based on area normalization of the TAG components and expressed as percentage area. Although not frequently used, peak-area ratios based on TAG profiles are a possible qualitative method for characterizing the TAG of palm oil and its fractions. This paper aims to compare these two detectors in terms of peak-area ratio, percentage peak area composition, and TAG elution profiles. The triacylglycerol (TAG) composition for palm oil and its fractions were analysed under similar HPLC conditions i.e. mobile phase and column. However, different sample concentrations were used for the detectors while remaining within the linearity limits of the detectors. These concentrations also gave a good baseline resolved separation for all the TAGs components. The results of the ELSD method's percentage area composition for the TAGs of palm oil and its fractions differed from those of RID. This indicates an unequal response of TAGs for palm oil and its fractions using the ELSD, also affecting the peak area ratios. They were found not to be equivalent to those obtained using the HPLC-RID. The ELSD method showed a better baseline separation for the TAGs components, with a more stable baseline as compared with the corresponding HPLC-RID. In conclusion, the percentage area compositions and peak-area ratios for palm oil and its fractions as derived from HPLC-ELSD and RID were not equivalent due to different responses of TAG components to the ELSD detector. The HPLC-RID has a better accuracy for percentage area composition and peak-area ratio because the TAG components response equally to the detector.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2015PhDT.......292H','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2015PhDT.......292H"><span>Evaluation of detector array technology for the verification of advanced intensity-modulated radiotherapy</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Hussien, Mohammad</p> <p></p> <p>Purpose: Quality assurance (QA) for intensity modulated radiotherapy (IMRT) has evolved substantially. In recent years, various ionization chamber or diode detector arrays have become commercially available, allowing pre-treatment absolute dose verification with near real-time results. This has led to a wide uptake of this technology to replace point dose and film dosimetry and to facilitate QA streamlining. However, arrays are limited by their spatial resolution giving rise to concerns about their response to clinically relevant deviations. The common factor in all commercial array systems is the reliance on the gamma index (γ) method to provide the quantitative evaluation of the measured dose distribution against the Treatment Planning System (TPS) calculated dose distribution. The mathematical definition of the gamma index presents computational challenges that can cause a variation in the calculation in different systems. The purpose of this thesis was to evaluate the suitability of detector array systems, combined with their implementation of the gamma index, in the verification and dosimetry audit of advanced IMRT. Method: The response of various commercial detector array systems (Delta4®, ArcCHECK®, and the PTW 2D-Array seven29™ and OCTAVIUS II™ phantom combination, Gafchromic® EBT2 and composite EPID measurements) to simulated deliberate changes in clinical IMRT and VMAT plans was evaluated. The variability of the gamma index calculation in the different systems was also evaluated by comparing against a bespoke Matlab-based gamma index analysis software. A novel methodology for using a commercial detector array in a dosimetry audit of rotational radiotherapy was then developed. Comparison was made between measurements using the detector array and those performed using ionization chambers, alanine and radiochromic film. The methodology was developed as part of the development of a national audit of rotational radiotherapy. Ten cancer centres were asked to create a rotational radiotherapy treatment plan for a three-dimensional treatment-planning-system (3DTPS) test and audited. Phantom measurements using a commercial 2D ionization chamber (IC) array were compared with measurements using 0.125cm3 ion chamber, Gafchromic film and alanine pellets in the same plane. Relative and absolute gamma index (γ) comparisons were made for Gafchromic film and 2D-Array planes respectively. A methodology for prospectively deriving appropriate gamma index acceptance criteria for detector array systems, via simulation of deliberate changes and receiver operator characteristic (ROC) analysis, has been developed. Results: In the event of clinically relevant delivery introduced changes, the detector array systems evaluated are able to detect some of these changes if suitable gamma index passing criteria, such as 2%/2mm, are used. Different computational approaches can produce variability in the calculation of the gamma index between different software implementations. For the same passing criteria, different devices and software combinations exhibit varying levels of agreement with the Matlab predicted gamma index analysis. This work has found that it is suitable to use a detector array in a dosimetry audit of rotational radiotherapy in place of standard systems of dosimetry such as ion chambers, alanine and film. Comparisons between individual detectors within the 2D-Array against the corresponding ion chamber and alanine measurement showed a statistically significant concordance correlation coefficient (ρc>0.998, p<0.001) with mean difference of -1.1%±1.1% and -0.8%±1.1%, respectively, in a high dose PTV. In the γ comparison between the 2D-Array and film it was found that the 2D-Array was more likely to fail in planes where there was a dose discrepancy due to the absolute analysis performed. A follow-up analysis of the library of measured data during the audit found that additional metrics such as the mean gamma index or dose differences over regions of interest can be gleaned from the measured dose distributions. Conclusions: It is important to understand the response and limitations of the gamma index analysis combined with the equipment and software in use. For the same pass-rate criteria, different devices and software combinations exhibit varying levels of agreement with the predicted γ analysis. It has been found that using a commercial detector array for a dosimetry audit of rotational radiotherapy is suitable in place of standard systems of dosimetry. A methodology for being able to prospectively ascertain appropriate gamma index acceptance criteria for the detector array system in use, via simulation of deliberate changes and ROC analysis, has been developed. It has been shown that setting appropriate tolerances can be achieved and should be performed as the methodology takes into account the configuration of the commercial system as well as the software implementation of the gamma index.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/20451914','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/20451914"><span>Analysis of aldehydes in beer by gas-diffusion microextraction: characterization by high-performance liquid chromatography-diode-array detection-atmospheric pressure chemical ionization-mass spectrometry.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Gonçalves, Luís Moreira; Magalhães, Paulo Jorge; Valente, Inês Maria; Pacheco, João Grosso; Dostálek, Pavel; Sýkora, David; Rodrigues, José António; Barros, Aquiles Araújo</p> <p>2010-06-11</p> <p>In this work, a recently developed extraction technique for sample preparation aiming the analysis of volatile and semi-volatile compounds named gas-diffusion microextraction (GDME) is applied in the chromatographic analysis of aldehydes in beer. Aldehydes-namely acetaldehyde (AA), methylpropanal (MA) and furfural (FA)-were simultaneously extracted and derivatized with 2,4-dinitrophenylhydrazine (DNPH), then the derivatives were separated and analyzed by high-performance liquid chromatography with spectrophotometric detection (HPLC-UV). The identity of the eluted compounds was confirmed by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass-spectrometry detection in the negative ion mode (HPLC-APCI-MS). The developed methodology showed good repeatability (ca. 5%) and linearity as well as good limits of detection (AA-12.3, FA-1.5 and MA 5.4microgL(-1)) and quantification (AA-41, FA-4.9 and MA 18microgL(-1)); it also appears to be competitive in terms of speed and cost of analysis. Copyright 2010 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/11271705','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/11271705"><span>Solid-phase microextraction coupled with high performance liquid chromatography: a complementary technique to solid-phase microextraction-gas chromatography for the analysis of pesticide residues in strawberries.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wang, Z; Hennion, B; Urruty, L; Montury, M</p> <p>2000-11-01</p> <p>Solid-phase microextraction coupled with high performance liquid chromatography has been studied for the analysis of methiocarb, napropamide, fenoxycarb and bupirimate in strawberries. The strawberries were blended and centrifuged. Then, an aliquot of the resulting extracting solution was subjected to solid-phase microextraction (SPME) on a 60 microns polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 45 min at room temperature. The extracted pesticides on the SPME fibre were desorbed into SPME/high performance liquid chromatography (HPLC) interface for HPLC analysis with diode-array detection (DAD). The method is organic solvent-free for the whole extraction process and is simple and easy to manipulate. The detection limits were shown to be at low microgram kg-1 level and the linear response covered the range from 0.05 to 2 mg kg-1 of pesticides in strawberries with a regression coefficient larger than 0.99. A good repeatability with RSDs between 2.92 and 9.25% was obtained, depending on compounds.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4200768','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4200768"><span>Recovering Bioactive Compounds from Olive Oil Filter Cake by Advanced Extraction Techniques</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Lozano-Sánchez, Jesús; Castro-Puyana, María; Mendiola, Jose A.; Segura-Carretero, Antonio; Cifuentes, Alejandro; Ibáñez, Elena</p> <p>2014-01-01</p> <p>The potential of by-products generated during extra-virgin olive oil (EVOO) filtration as a natural source of phenolic compounds (with demonstrated bioactivity) has been evaluated using pressurized liquid extraction (PLE) and considering mixtures of two GRAS (generally recognized as safe) solvents (ethanol and water) at temperatures ranging from 40 to 175 °C. The extracts were characterized by high-performance liquid chromatography (HPLC) coupled to diode array detection (DAD) and electrospray time-of-flight mass spectrometry (HPLC-DAD-ESI-TOF/MS) to determine the phenolic-composition of the filter cake. The best isolation procedure to extract the phenolic fraction from the filter cake was accomplished using ethanol and water (50:50, v/v) at 120 °C. The main phenolic compounds identified in the samples were characterized as phenolic alcohols or derivatives (hydroxytyrosol and its oxidation product), secoiridoids (decarboxymethylated and hydroxylated forms of oleuropein and ligstroside aglycones), flavones (luteolin and apigenin) and elenolic acid derivatives. The PLE extraction process can be applied to produce enriched extracts with applications as bioactive food ingredients, as well as nutraceuticals. PMID:25226536</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_25 --> <div class="footer-extlink text-muted" style="margin-bottom:1rem; text-align:center;">Some links on this page may take you to non-federal websites. Their policies may differ from this site.</div> </div><!-- container --> <a id="backToTop" href="#top"> Top </a> <footer> <nav> <ul class="links"> <li><a href="/sitemap.html">Site Map</a></li> <li><a href="/website-policies.html">Website Policies</a></li> <li><a href="https://www.energy.gov/vulnerability-disclosure-policy" target="_blank">Vulnerability Disclosure Program</a></li> <li><a href="/contact.html">Contact Us</a></li> </ul> </nav> </footer> <script type="text/javascript"><!-- // var lastDiv = ""; function showDiv(divName) { // hide last div if (lastDiv) { document.getElementById(lastDiv).className = "hiddenDiv"; } //if value of the box is not nothing and an object with that name exists, then change the class if (divName && document.getElementById(divName)) { document.getElementById(divName).className = "visibleDiv"; lastDiv = divName; } } //--> </script> <script> /** * Function that tracks a click on an outbound link in Google Analytics. * This function takes a valid URL string as an argument, and uses that URL string * as the event label. */ var trackOutboundLink = function(url,collectionCode) { try { h = window.open(url); setTimeout(function() { ga('send', 'event', 'topic-page-click-through', collectionCode, url); }, 1000); } catch(err){} }; </script> <!-- Google Analytics --> <script> (function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){ (i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o), m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m) })(window,document,'script','//www.google-analytics.com/analytics.js','ga'); ga('create', 'UA-1122789-34', 'auto'); ga('send', 'pageview'); </script> <!-- End Google Analytics --> <script> showDiv('page_1') </script> </body> </html>