Implicit prosody mining based on the human eye image capture technology
NASA Astrophysics Data System (ADS)
Gao, Pei-pei; Liu, Feng
2013-08-01
The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.
Cater, Kathleen C; Harbell, John W
2008-01-01
The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.
Intraocular lens based on double-liquid variable-focus lens.
Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2014-01-10
In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.
Toward statistical modeling of saccadic eye-movement and visual saliency.
Sun, Xiaoshuai; Yao, Hongxun; Ji, Rongrong; Liu, Xian-Ming
2014-11-01
In this paper, we present a unified statistical framework for modeling both saccadic eye movements and visual saliency. By analyzing the statistical properties of human eye fixations on natural images, we found that human attention is sparsely distributed and usually deployed to locations with abundant structural information. This observations inspired us to model saccadic behavior and visual saliency based on super-Gaussian component (SGC) analysis. Our model sequentially obtains SGC using projection pursuit, and generates eye movements by selecting the location with maximum SGC response. Besides human saccadic behavior simulation, we also demonstrated our superior effectiveness and robustness over state-of-the-arts by carrying out dense experiments on synthetic patterns and human eye fixation benchmarks. Multiple key issues in saliency modeling research, such as individual differences, the effects of scale and blur, are explored in this paper. Based on extensive qualitative and quantitative experimental results, we show promising potentials of statistical approaches for human behavior research.
Computational Model-Based Prediction of Human Episodic Memory Performance Based on Eye Movements
NASA Astrophysics Data System (ADS)
Sato, Naoyuki; Yamaguchi, Yoko
Subjects' episodic memory performance is not simply reflected by eye movements. We use a ‘theta phase coding’ model of the hippocampus to predict subjects' memory performance from their eye movements. Results demonstrate the ability of the model to predict subjects' memory performance. These studies provide a novel approach to computational modeling in the human-machine interface.
NASA Astrophysics Data System (ADS)
Yuan, Yuan; Fang, Tao; Sun, Min Yuan; Gao, Wei Nan; Zhang, Shuo; Bi, Yong
2018-07-01
Laser speckle is a major issue for laser projection displays. In various techniques of speckle reduction, speckle is quantified with a speckle contrast value. However, the measured speckle contrast is poorly suited for the subjective speckle perception of a human observer. Here, we investigate the characteristics of human eyes and propose a simplified optical transfer function of human eyes. Accordingly, two human-eye-modeled speckle measuring sets are configured. Based on the experimental set, an advanced electromagnetic micro-scanning mirror (EM-MSM) is exploited; which is of 6.5 mm in diameter and its half angle is 7.8° for a horizontal scan and 6.53° for a vertical scan. Finally, we quantitatively show that images generated with an EM-MSM exhibit superior quality. By providing human-eye-modeled speckle measuring instruments and an EM-MSM for speckle reduction, it has a promising promotion to laser projector development.
Double-pass measurement of human eye aberrations: limitations and practical realization
NASA Astrophysics Data System (ADS)
Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.
2004-11-01
The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.
Eye gazing direction inspection based on image processing technique
NASA Astrophysics Data System (ADS)
Hao, Qun; Song, Yong
2005-02-01
According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.
NEIBank: Genomics and bioinformatics resources for vision research
Peterson, Katherine; Gao, James; Buchoff, Patee; Jaworski, Cynthia; Bowes-Rickman, Catherine; Ebright, Jessica N.; Hauser, Michael A.; Hoover, David
2008-01-01
NEIBank is an integrated resource for genomics and bioinformatics in vision research. It includes expressed sequence tag (EST) data and sequence-verified cDNA clones for multiple eye tissues of several species, web-based access to human eye-specific SAGE data through EyeSAGE, and comprehensive, annotated databases of known human eye disease genes and candidate disease gene loci. All expression- and disease-related data are integrated in EyeBrowse, an eye-centric genome browser. NEIBank provides a comprehensive overview of current knowledge of the transcriptional repertoires of eye tissues and their relation to pathology. PMID:18648525
Proposed new classification scheme for chemical injury to the human eye.
Bagley, Daniel M; Casterton, Phillip L; Dressler, William E; Edelhauser, Henry F; Kruszewski, Francis H; McCulley, James P; Nussenblatt, Robert B; Osborne, Rosemarie; Rothenstein, Arthur; Stitzel, Katherine A; Thomas, Karluss; Ward, Sherry L
2006-07-01
Various ocular alkali burn classification schemes have been published and used to grade human chemical eye injuries for the purpose of identifying treatments and forecasting outcomes. The ILSI chemical eye injury classification scheme was developed for the additional purpose of collecting detailed human eye injury data to provide information on the mechanisms associated with chemical eye injuries. This information will have clinical application, as well as use in the development and validation of new methods to assess ocular toxicity. A panel of ophthalmic researchers proposed the new classification scheme based upon current knowledge of the mechanisms of eye injury, and their collective clinical and research experience. Additional ophthalmologists and researchers were surveyed to critique the scheme. The draft scheme was revised, and the proposed scheme represents the best consensus from at least 23 physicians and scientists. The new scheme classifies chemical eye injury into five categories based on clinical signs, symptoms, and expected outcomes. Diagnostic classification is based primarily on two clinical endpoints: (1) the extent (area) of injury at the limbus, and (2) the degree of injury (area and depth) to the cornea. The new classification scheme provides a uniform system for scoring eye injury across chemical classes, and provides enough detail for the clinician to collect data that will be relevant to identifying the mechanisms of ocular injury.
Driver fatigue detection based on eye state.
Lin, Lizong; Huang, Chao; Ni, Xiaopeng; Wang, Jiawen; Zhang, Hao; Li, Xiao; Qian, Zhiqin
2015-01-01
Nowadays, more and more traffic accidents occur because of driver fatigue. In order to reduce and prevent it, in this study, a calculation method using PERCLOS (percentage of eye closure time) parameter characteristics based on machine vision was developed. It determined whether a driver's eyes were in a fatigue state according to the PERCLOS value. The overall workflow solutions included face detection and tracking, detection and location of the human eye, human eye tracking, eye state recognition, and driver fatigue testing. The key aspects of the detection system incorporated the detection and location of human eyes and driver fatigue testing. The simplified method of measuring the PERCLOS value of the driver was to calculate the ratio of the eyes being open and closed with the total number of frames for a given period. If the eyes were closed more than the set threshold in the total number of frames, the system would alert the driver. Through many experiments, it was shown that besides the simple detection algorithm, the rapid computing speed, and the high detection and recognition accuracies of the system, the system was demonstrated to be in accord with the real-time requirements of a driver fatigue detection system.
Research of the aberrations of human eyes with accommodation based on eye model
NASA Astrophysics Data System (ADS)
Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi
2011-06-01
The variation of the wavefront aberration with accommodation was investigated based on the eye model of Gullstrand-Le Grand. The anterior lens radius was optimized at different accommodation to focus the image at the retina, and the RMS and PV wave-front error of human eye were compared at different accommodation. The PV value of wavefront aberration from 0.718 waves increases gradually to 0.904 waves and RMS value from 0.21 waves to 0.26 waves when accommodative stimuli varies from 0 to - 5 diopters. The change of PV value is 0.186 waves which is less than the Rayleigh diffraction limit λ/4, and the change of RMS is 0.05 which under Marechal diffraction limit λ/14. Therefore, the change of the wavefront aberration caused accommodation can be ignored when wavefront aberrations in the human eye are corrected with surgery or wearing glasses.
Simulation of wave propagation inside a human eye: acoustic eye model (AEM)
NASA Astrophysics Data System (ADS)
Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.
2018-02-01
The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.
Optical properties of the mouse eye
Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.
2011-01-01
The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598
Personal identification by eyes.
Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana
2011-09-01
Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.
Optimizations and Applications in Head-Mounted Video-Based Eye Tracking
ERIC Educational Resources Information Center
Li, Feng
2011-01-01
Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…
Imaging shear stress distribution and evaluating the stress concentration factor of the human eye
NASA Astrophysics Data System (ADS)
Joseph Antony, S.
2015-03-01
Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.
NASA Astrophysics Data System (ADS)
Gao, Pei-pei; Liu, Feng
2016-10-01
With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.
Dose conversion coefficients for neutron exposure to the lens of the human eye.
Manger, R P; Bellamy, M B; Eckerman, K F
2012-03-01
Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 × 10(-9) to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.
Full ocular biometry through dual-depth whole-eye optical coherence tomography
Kim, Hyung-Jin; Kim, Minji; Hyeon, Min Gyu; Choi, Youngwoon; Kim, Beop-Min
2018-01-01
We propose a new method of determining the optical axis (OA), pupillary axis (PA), and visual axis (VA) of the human eye by using dual-depth whole-eye optical coherence tomography (OCT). These axes, as well as the angles “α” between the OA and VA and “κ” between PA and VA, are important in many ophthalmologic applications, especially in refractive surgery. Whole-eye images are reconstructed based on simultaneously acquired images of the anterior segment and retina. The light from a light source is split into two orthogonal polarization components for imaging the anterior segment and retina, respectively. The OA and PA are identified based on their geometric definitions by using the anterior segment image only, while the VA is detected through accurate correlation between the two images. The feasibility of our approach was tested using a model eye and human subjects. PMID:29552378
Research on the liquid crystal adaptive optics system for human retinal imaging
NASA Astrophysics Data System (ADS)
Zhang, Lei; Tong, Shoufeng; Song, Yansong; Zhao, Xin
2013-12-01
The blood vessels only in Human eye retinal can be observed directly. Many diseases that are not obvious in their early symptom can be diagnosed through observing the changes of distal micro blood vessel. In order to obtain the high resolution human retinal images,an adaptive optical system for correcting the aberration of the human eye was designed by using the Shack-Hartmann wavefront sensor and the Liquid Crystal Spatial Light Modulator(LCLSM) .For a subject eye with 8m-1 (8D)myopia, the wavefront error is reduced to 0.084 λ PV and 0.12 λRMS after adaptive optics(AO) correction ,which has reached diffraction limit.The results show that the LCLSM based AO system has the ability of correcting the aberration of the human eye efficiently,and making the blurred photoreceptor cell to clearly image on a CCD camera.
NASA Astrophysics Data System (ADS)
Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai
2013-12-01
In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.
Zimmermann, Jan; Vazquez, Yuriria; Glimcher, Paul W; Pesaran, Bijan; Louie, Kenway
2016-09-01
Video-based noninvasive eye trackers are an extremely useful tool for many areas of research. Many open-source eye trackers are available but current open-source systems are not designed to track eye movements with the temporal resolution required to investigate the mechanisms of oculomotor behavior. Commercial systems are available but employ closed source hardware and software and are relatively expensive, limiting wide-spread use. Here we present Oculomatic, an open-source software and modular hardware solution to eye tracking for use in humans and non-human primates. Oculomatic features high temporal resolution (up to 600Hz), real-time eye tracking with high spatial accuracy (<0.5°), and low system latency (∼1.8ms, 0.32ms STD) at a relatively low-cost. Oculomatic compares favorably to our existing scleral search-coil system while being fully non invasive. We propose that Oculomatic can support a wide range of research into the properties and neural mechanisms of oculomotor behavior. Copyright © 2016 Elsevier B.V. All rights reserved.
Dose conversion coefficients for neutron exposure to the lens of the human eye
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manger, Ryan P; Bellamy, Michael B; Eckerman, Keith F
Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematicalmore » phantom in the MCNPX transport calculations.« less
Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?
NASA Astrophysics Data System (ADS)
De Martini, Francesco
2010-05-01
In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.
Effects of Detailed Illustrations on Science Learning: An Eye-Tracking Study
ERIC Educational Resources Information Center
Lin, Yu Ying; Holmqvist, Kenneth; Miyoshi, Kiyofumi; Ashida, Hiroshi
2017-01-01
The eye-tracking method was used to assess the influence of detailed, colorful illustrations on reading behaviors and learning outcomes. Based on participants' subjective ratings in a pre-study, we selected eight one-page human anatomy lessons. In the main study, participants learned these eight human anatomy lessons; four were accompanied by…
Su, Hao; Dickstein-Fischer, Laurie; Harrington, Kevin; Fu, Qiushi; Lu, Weina; Huang, Haibo; Cole, Gregory; Fischer, Gregory S
2010-01-01
This paper presents the development of new prismatic actuation approach and its application in human-safe humanoid head design. To reduce actuator output impedance and mitigate unexpected external shock, the prismatic actuation method uses cables to drive a piston with preloaded spring. By leveraging the advantages of parallel manipulator and cable-driven mechanism, the developed neck has a parallel manipulator embodiment with two cable-driven limbs embedded with preloaded springs and one passive limb. The eye mechanism is adapted for low-cost webcam with succinct "ball-in-socket" structure. Based on human head anatomy and biomimetics, the neck has 3 degree of freedom (DOF) motion: pan, tilt and one decoupled roll while each eye has independent pan and synchronous tilt motion (3 DOF eyes). A Kalman filter based face tracking algorithm is implemented to interact with the human. This neck and eye structure is translatable to other human-safe humanoid robots. The robot's appearance reflects a non-threatening image of a penguin, which can be translated into a possible therapeutic intervention for children with Autism Spectrum Disorders.
Eye Tracking Based Control System for Natural Human-Computer Interaction
Lin, Shu-Fan
2017-01-01
Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design. PMID:29403528
Eye Tracking Based Control System for Natural Human-Computer Interaction.
Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan
2017-01-01
Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.
Mala, S.; Latha, K.
2014-01-01
Activity recognition is needed in different requisition, for example, reconnaissance system, patient monitoring, and human-computer interfaces. Feature selection plays an important role in activity recognition, data mining, and machine learning. In selecting subset of features, an efficient evolutionary algorithm Differential Evolution (DE), a very efficient optimizer, is used for finding informative features from eye movements using electrooculography (EOG). Many researchers use EOG signals in human-computer interactions with various computational intelligence methods to analyze eye movements. The proposed system involves analysis of EOG signals using clearness based features, minimum redundancy maximum relevance features, and Differential Evolution based features. This work concentrates more on the feature selection algorithm based on DE in order to improve the classification for faultless activity recognition. PMID:25574185
Mala, S; Latha, K
2014-01-01
Activity recognition is needed in different requisition, for example, reconnaissance system, patient monitoring, and human-computer interfaces. Feature selection plays an important role in activity recognition, data mining, and machine learning. In selecting subset of features, an efficient evolutionary algorithm Differential Evolution (DE), a very efficient optimizer, is used for finding informative features from eye movements using electrooculography (EOG). Many researchers use EOG signals in human-computer interactions with various computational intelligence methods to analyze eye movements. The proposed system involves analysis of EOG signals using clearness based features, minimum redundancy maximum relevance features, and Differential Evolution based features. This work concentrates more on the feature selection algorithm based on DE in order to improve the classification for faultless activity recognition.
Model of the Human Eye Based on ABCD Matrix
NASA Astrophysics Data System (ADS)
González, G. Díaz; Castillo, M. David Iturbe
2008-04-01
At the moment several models of the human eye exist, nevertheless the gradient index models of the human lens (crystalline) have received little attention in optometry and vision sciences, although they consider how the refractive index and the refracting power can change with the accommodation. On the other hand, in study fields like ophthalmology and optometry, exist cases where there is a lack of information about the factors that influence the change of refractive power and therefore the focal length of the eye. By such reason, in this paper we present a model of the human eye based on the ABCD matrix in order to describe the propagation of light rays, that can be understood by professional people in optics, ophthalmology and optometry, and the dispersions of the different ocular mediums are taken into account,. The aim of the model is to obtain data about the refractive power of the eye under different considerations, such as: changes in wavelength, radius of curvature and thicknesses of the ocular mediums. We present results of simulations in Matlab of our model, assuming that the object is punctual and is placed to a certain distance of the eye, and considering at the beginning to the crystalline like a medium with fixed refractive index, and after like a gradient lens. By means of graphs, we show the total refractive power of the eye and its form and type of dependence with respect to variations in radius of curvature and thicknesses of the cornea and crystalline, as well as variations in the thickness of the previous and later cameras.
Eye-head coordination during free exploration in human and cat.
Einhäuser, Wolfgang; Moeller, Gudrun U; Schumann, Frank; Conradt, Jörg; Vockeroth, Johannes; Bartl, Klaus; Schneider, Erich; König, Peter
2009-05-01
Eye, head, and body movements jointly control the direction of gaze and the stability of retinal images in most mammalian species. The contribution of the individual movement components, however, will largely depend on the ecological niche the animal occupies and the layout of the animal's retina, in particular its photoreceptor density distribution. Here the relative contribution of eye-in-head and head-in-world movements in cats is measured, and the results are compared to recent human data. For the cat, a lightweight custom-made head-mounted video setup was used (CatCam). Human data were acquired with the novel EyeSeeCam device, which measures eye position to control a gaze-contingent camera in real time. For both species, analysis was based on simultaneous recordings of eye and head movements during free exploration of a natural environment. Despite the substantial differences in ecological niche, photoreceptor density, and saccade frequency, eye-movement characteristics in both species are remarkably similar. Coordinated eye and head movements dominate the dynamics of the retinal input. Interestingly, compensatory (gaze-stabilizing) movements play a more dominant role in humans than they do in cats. This finding was interpreted to be a consequence of substantially different timescales for head movements, with cats' head movements showing about a 5-fold faster dynamics than humans. For both species, models and laboratory experiments therefore need to account for this rich input dynamic to obtain validity for ecologically realistic settings.
NASA Astrophysics Data System (ADS)
Lauinger, Norbert
2004-10-01
The human eye is a good model for the engineering of optical correlators. Three prominent intelligent functionalities in human vision could in the near future become realized by a new diffractive-optical hardware design of optical imaging sensors: (1) Illuminant-adaptive RGB-based color Vision, (2) Monocular 3D Vision based on RGB data processing, (3) Patchwise fourier-optical Object-Classification and Identification. The hardware design of the human eye has specific diffractive-optical elements (DOE's) in aperture and in image space and seems to execute the three jobs at -- or not far behind -- the loci of the images of objects.
A boussinesq model of natural convection in the human eye and the formation of Krukenberg's spindle.
Heys, Jeffrey J; Barocas, Victor H
2002-03-01
The cornea of the human eye is cooled by the surrounding air and by evaporation of the tear film. The temperature difference between the cornea and the iris (at core body temperature) causes circulation of the aqueous humor in the anterior chamber of the eye. Others have suggested that the circulation pattern governs the shape of the Krukenberg spindle, a distinctive vertical band of pigment on the posterior cornea surface in some pathologies. We modeled aqueous humor flow the human eye, treating the humor as a Boussinesq fluid and setting the corneal temperature based on infrared surface temperature measurements. The model predicts convection currents in the anterior chamber with velocities comparable to those resulting from forced flow through the gap between the iris and lens. When paths of pigment particles are calculated based on the predicted flow field, the particles circulate throughout the anterior chamber but tend to be near the vertical centerline of the eye for a greatest period of time. Further, the particles are usually in close proximity to the cornea only when they are near the vertical centerline. We conclude that the convective flow pattern of aqueous humor is consistent with a vertical pigment spindle.
Adaptive Optics for the Human Eye
NASA Astrophysics Data System (ADS)
Williams, D. R.
2000-05-01
Adaptive optics can extend not only the resolution of ground-based telescopes, but also the human eye. Both static and dynamic aberrations in the cornea and lens of the normal eye limit its optical quality. Though it is possible to correct defocus and astigmatism with spectacle lenses, higher order aberrations remain. These aberrations blur vision and prevent us from seeing at the fundamental limits set by the retina and brain. They also limit the resolution of cameras to image the living retina, cameras that are a critical for the diagnosis and treatment of retinal disease. I will describe an adaptive optics system that measures the wave aberration of the eye in real time and compensates for it with a deformable mirror, endowing the human eye with unprecedented optical quality. This instrument provides fresh insight into the ultimate limits on human visual acuity, reveals for the first time images of the retinal cone mosaic responsible for color vision, and points the way to contact lenses and laser surgical methods that could enhance vision beyond what is currently possible today. Supported by the NSF Science and Technology Center for Adaptive Optics, the National Eye Institute, and Bausch and Lomb, Inc.
Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min
2017-01-01
Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350
Ito, Norie; Barnes, Graham R; Fukushima, Junko; Fukushima, Kikuro; Warabi, Tateo
2013-08-01
Using a cue-dependent memory-based smooth-pursuit task previously applied to monkeys, we examined the effects of visual motion-memory on smooth-pursuit eye movements in normal human subjects and compared the results with those of the trained monkeys. These results were also compared with those during simple ramp-pursuit that did not require visual motion-memory. During memory-based pursuit, all subjects exhibited virtually no errors in either pursuit-direction or go/no-go selection. Tracking eye movements of humans and monkeys were similar in the two tasks, but tracking eye movements were different between the two tasks; latencies of the pursuit and corrective saccades were prolonged, initial pursuit eye velocity and acceleration were lower, peak velocities were lower, and time to reach peak velocities lengthened during memory-based pursuit. These characteristics were similar to anticipatory pursuit initiated by extra-retinal components during the initial extinction task of Barnes and Collins (J Neurophysiol 100:1135-1146, 2008b). We suggest that the differences between the two tasks reflect differences between the contribution of extra-retinal and retinal components. This interpretation is supported by two further studies: (1) during popping out of the correct spot to enhance retinal image-motion inputs during memory-based pursuit, pursuit eye velocities approached those during simple ramp-pursuit, and (2) during initial blanking of spot motion during memory-based pursuit, pursuit components appeared in the correct direction. Our results showed the importance of extra-retinal mechanisms for initial pursuit during memory-based pursuit, which include priming effects and extra-retinal drive components. Comparison with monkey studies on neuronal responses and model analysis suggested possible pathways for the extra-retinal mechanisms.
Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging.
Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R
2015-12-15
Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A , 1985, 2 .] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.
Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging
NASA Astrophysics Data System (ADS)
Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.
2015-12-01
Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.
Wavefront sensorless adaptive optics ophthalmoscopy in the human eye
Hofer, Heidi; Sredar, Nripun; Queener, Hope; Li, Chaohong; Porter, Jason
2011-01-01
Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor ‘beacon’ can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. PMID:21934779
Dynamic Features for Iris Recognition.
da Costa, R M; Gonzaga, A
2012-08-01
The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.
Intraocular lens design for treating high myopia based on individual eye model
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong
2007-02-01
In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.
Steering a Tractor by Means of an EMG-Based Human-Machine Interface
Gomez-Gil, Jaime; San-Jose-Gonzalez, Israel; Nicolas-Alonso, Luis Fernando; Alonso-Garcia, Sergio
2011-01-01
An electromiographic (EMG)-based human-machine interface (HMI) is a communication pathway between a human and a machine that operates by means of the acquisition and processing of EMG signals. This article explores the use of EMG-based HMIs in the steering of farm tractors. An EPOC, a low-cost human-computer interface (HCI) from the Emotiv Company, was employed. This device, by means of 14 saline sensors, measures and processes EMG and electroencephalographic (EEG) signals from the scalp of the driver. In our tests, the HMI took into account only the detection of four trained muscular events on the driver’s scalp: eyes looking to the right and jaw opened, eyes looking to the right and jaw closed, eyes looking to the left and jaw opened, and eyes looking to the left and jaw closed. The EMG-based HMI guidance was compared with manual guidance and with autonomous GPS guidance. A driver tested these three guidance systems along three different trajectories: a straight line, a step, and a circumference. The accuracy of the EMG-based HMI guidance was lower than the accuracy obtained by manual guidance, which was lower in turn than the accuracy obtained by the autonomous GPS guidance; the computed standard deviations of error to the desired trajectory in the straight line were 16 cm, 9 cm, and 4 cm, respectively. Since the standard deviation between the manual guidance and the EMG-based HMI guidance differed only 7 cm, and this difference is not relevant in agricultural steering, it can be concluded that it is possible to steer a tractor by an EMG-based HMI with almost the same accuracy as with manual steering. PMID:22164006
Steering a tractor by means of an EMG-based human-machine interface.
Gomez-Gil, Jaime; San-Jose-Gonzalez, Israel; Nicolas-Alonso, Luis Fernando; Alonso-Garcia, Sergio
2011-01-01
An electromiographic (EMG)-based human-machine interface (HMI) is a communication pathway between a human and a machine that operates by means of the acquisition and processing of EMG signals. This article explores the use of EMG-based HMIs in the steering of farm tractors. An EPOC, a low-cost human-computer interface (HCI) from the Emotiv Company, was employed. This device, by means of 14 saline sensors, measures and processes EMG and electroencephalographic (EEG) signals from the scalp of the driver. In our tests, the HMI took into account only the detection of four trained muscular events on the driver's scalp: eyes looking to the right and jaw opened, eyes looking to the right and jaw closed, eyes looking to the left and jaw opened, and eyes looking to the left and jaw closed. The EMG-based HMI guidance was compared with manual guidance and with autonomous GPS guidance. A driver tested these three guidance systems along three different trajectories: a straight line, a step, and a circumference. The accuracy of the EMG-based HMI guidance was lower than the accuracy obtained by manual guidance, which was lower in turn than the accuracy obtained by the autonomous GPS guidance; the computed standard deviations of error to the desired trajectory in the straight line were 16 cm, 9 cm, and 4 cm, respectively. Since the standard deviation between the manual guidance and the EMG-based HMI guidance differed only 7 cm, and this difference is not relevant in agricultural steering, it can be concluded that it is possible to steer a tractor by an EMG-based HMI with almost the same accuracy as with manual steering.
Visual Data Mining: An Exploratory Approach to Analyzing Temporal Patterns of Eye Movements
ERIC Educational Resources Information Center
Yu, Chen; Yurovsky, Daniel; Xu, Tian
2012-01-01
Infant eye movements are an important behavioral resource to understand early human development and learning. But the complexity and amount of gaze data recorded from state-of-the-art eye-tracking systems also pose a challenge: how does one make sense of such dense data? Toward this goal, this article describes an interactive approach based on…
Eye gaze tracking based on the shape of pupil image
NASA Astrophysics Data System (ADS)
Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng
2018-01-01
Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.
Wu, Shang-Lin; Liao, Lun-De; Lu, Shao-Wei; Jiang, Wei-Ling; Chen, Shi-An; Lin, Chin-Teng
2013-08-01
Electrooculography (EOG) signals can be used to control human-computer interface (HCI) systems, if properly classified. The ability to measure and process these signals may help HCI users to overcome many of the physical limitations and inconveniences in daily life. However, there are currently no effective multidirectional classification methods for monitoring eye movements. Here, we describe a classification method used in a wireless EOG-based HCI device for detecting eye movements in eight directions. This device includes wireless EOG signal acquisition components, wet electrodes and an EOG signal classification algorithm. The EOG classification algorithm is based on extracting features from the electrical signals corresponding to eight directions of eye movement (up, down, left, right, up-left, down-left, up-right, and down-right) and blinking. The recognition and processing of these eight different features were achieved in real-life conditions, demonstrating that this device can reliably measure the features of EOG signals. This system and its classification procedure provide an effective method for identifying eye movements. Additionally, it may be applied to study eye functions in real-life conditions in the near future.
Gácsi, Márta; Miklósi, Adám; Varga, Orsolya; Topál, József; Csányi, Vilmos
2004-07-01
The ability of animals to use behavioral/facial cues in detection of human attention has been widely investigated. In this test series we studied the ability of dogs to recognize human attention in different experimental situations (ball-fetching game, fetching objects on command, begging from humans). The attentional state of the humans was varied along two variables: (1) facing versus not facing the dog; (2) visible versus non-visible eyes. In the first set of experiments (fetching) the owners were told to take up different body positions (facing or not facing the dog) and to either cover or not cover their eyes with a blindfold. In the second set of experiments (begging) dogs had to choose between two eating humans based on either the visibility of the eyes or direction of the face. Our results show that the efficiency of dogs to discriminate between "attentive" and "inattentive" humans depended on the context of the test, but they could rely on the orientation of the body, the orientation of the head and the visibility of the eyes. With the exception of the fetching-game situation, they brought the object to the front of the human (even if he/she turned his/her back towards the dog), and preferentially begged from the facing (or seeing) human. There were also indications that dogs were sensitive to the visibility of the eyes because they showed increased hesitative behavior when approaching a blindfolded owner, and they also preferred to beg from the person with visible eyes. We conclude that dogs are able to rely on the same set of human facial cues for detection of attention, which form the behavioral basis of understanding attention in humans. Showing the ability of recognizing human attention across different situations dogs proved to be more flexible than chimpanzees investigated in similar circumstances.
Wollstein, Andreas; Walsh, Susan; Liu, Fan; Chakravarthy, Usha; Rahu, Mati; Seland, Johan H; Soubrane, Gisèle; Tomazzoli, Laura; Topouzis, Fotis; Vingerling, Johannes R; Vioque, Jesus; Böhringer, Stefan; Fletcher, Astrid E; Kayser, Manfred
2017-02-27
Success of genetic association and the prediction of phenotypic traits from DNA are known to depend on the accuracy of phenotype characterization, amongst other parameters. To overcome limitations in the characterization of human iris pigmentation, we introduce a fully automated approach that specifies the areal proportions proposed to represent differing pigmentation types, such as pheomelanin, eumelanin, and non-pigmented areas within the iris. We demonstrate the utility of this approach using high-resolution digital eye imagery and genotype data from 12 selected SNPs from over 3000 European samples of seven populations that are part of the EUREYE study. In comparison to previous quantification approaches, (1) we achieved an overall improvement in eye colour phenotyping, which provides a better separation of manually defined eye colour categories. (2) Single nucleotide polymorphisms (SNPs) known to be involved in human eye colour variation showed stronger associations with our approach. (3) We found new and confirmed previously noted SNP-SNP interactions. (4) We increased SNP-based prediction accuracy of quantitative eye colour. Our findings exemplify that precise quantification using the perceived biological basis of pigmentation leads to enhanced genetic association and prediction of eye colour. We expect our approach to deliver new pigmentation genes when applied to genome-wide association testing.
Wollstein, Andreas; Walsh, Susan; Liu, Fan; Chakravarthy, Usha; Rahu, Mati; Seland, Johan H.; Soubrane, Gisèle; Tomazzoli, Laura; Topouzis, Fotis; Vingerling, Johannes R.; Vioque, Jesus; Böhringer, Stefan; Fletcher, Astrid E.; Kayser, Manfred
2017-01-01
Success of genetic association and the prediction of phenotypic traits from DNA are known to depend on the accuracy of phenotype characterization, amongst other parameters. To overcome limitations in the characterization of human iris pigmentation, we introduce a fully automated approach that specifies the areal proportions proposed to represent differing pigmentation types, such as pheomelanin, eumelanin, and non-pigmented areas within the iris. We demonstrate the utility of this approach using high-resolution digital eye imagery and genotype data from 12 selected SNPs from over 3000 European samples of seven populations that are part of the EUREYE study. In comparison to previous quantification approaches, (1) we achieved an overall improvement in eye colour phenotyping, which provides a better separation of manually defined eye colour categories. (2) Single nucleotide polymorphisms (SNPs) known to be involved in human eye colour variation showed stronger associations with our approach. (3) We found new and confirmed previously noted SNP-SNP interactions. (4) We increased SNP-based prediction accuracy of quantitative eye colour. Our findings exemplify that precise quantification using the perceived biological basis of pigmentation leads to enhanced genetic association and prediction of eye colour. We expect our approach to deliver new pigmentation genes when applied to genome-wide association testing. PMID:28240252
Human lacrimal gland regeneration: Perspectives and review of literature
Tiwari, Shubha; Ali, Mohammad Javed; Vemuganti, Geeta K.
2013-01-01
The human lacrimal gland is an essential component of the lacrimal functional unit (LFU). Any perturbation of this unit can lead to the debilitating morbid condition called the dry eye syndrome (DES). The current line of therapy available for dry eye remains supportive and palliative with the patient being dependent on life long and frequent administration of lubricating eye drops. Even advanced therapies like punctual plugs, cyclosporine B administration, and salivary gland auto-transplantation have led to a limited success. Under these scenarios, the option of cell based therapy needs to be explored to provide better and long term relief to these patients. This review gives an overview of the efforts in lacrimal gland regeneration and examines the past and ongoing research in cell based therapies in animals as well as human lacrimal gland cultures. The authors discuss their first of its kind functionally viable human lacrimal gland in vitro culture system from fresh exenteration specimens. A brief overview of research in near future and the potential implications of lacrimal gland regenerative therapies have been discussed. PMID:24526853
Human lacrimal gland regeneration: Perspectives and review of literature.
Tiwari, Shubha; Ali, Mohammad Javed; Vemuganti, Geeta K
2014-01-01
The human lacrimal gland is an essential component of the lacrimal functional unit (LFU). Any perturbation of this unit can lead to the debilitating morbid condition called the dry eye syndrome (DES). The current line of therapy available for dry eye remains supportive and palliative with the patient being dependent on life long and frequent administration of lubricating eye drops. Even advanced therapies like punctual plugs, cyclosporine B administration, and salivary gland auto-transplantation have led to a limited success. Under these scenarios, the option of cell based therapy needs to be explored to provide better and long term relief to these patients. This review gives an overview of the efforts in lacrimal gland regeneration and examines the past and ongoing research in cell based therapies in animals as well as human lacrimal gland cultures. The authors discuss their first of its kind functionally viable human lacrimal gland in vitro culture system from fresh exenteration specimens. A brief overview of research in near future and the potential implications of lacrimal gland regenerative therapies have been discussed.
Motion-adaptive model-assisted compatible coding with spatiotemporal scalability
NASA Astrophysics Data System (ADS)
Lee, JaeBeom; Eleftheriadis, Alexandros
1997-01-01
We introduce the concept of motion adaptive spatio-temporal model-assisted compatible (MA-STMAC) coding, a technique to selectively encode areas of different importance to the human eye in terms of space and time in moving images with the consideration of object motion. PRevious STMAC was proposed base don the fact that human 'eye contact' and 'lip synchronization' are very important in person-to-person communication. Several areas including the eyes and lips need different types of quality, since different areas have different perceptual significance to human observers. The approach provides a better rate-distortion tradeoff than conventional image coding techniques base don MPEG-1, MPEG- 2, H.261, as well as H.263. STMAC coding is applied on top of an encoder, taking full advantage of its core design. Model motion tracking in our previous STMAC approach was not automatic. The proposed MA-STMAC coding considers the motion of the human face within the STMAC concept using automatic area detection. Experimental results are given using ITU-T H.263, addressing very low bit-rate compression.
Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi
2004-01-01
Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475
System for assisted mobility using eye movements based on electrooculography.
Barea, Rafael; Boquete, Luciano; Mazo, Manuel; López, Elena
2002-12-01
This paper describes an eye-control method based on electrooculography (EOG) to develop a system for assisted mobility. One of its most important features is its modularity, making it adaptable to the particular needs of each user according to the type and degree of handicap involved. An eye model based on electroculographic signal is proposed and its validity is studied. Several human-machine interfaces (HMI) based on EOG are commented, focusing our study on guiding and controlling a wheelchair for disabled people, where the control is actually effected by eye movements within the socket. Different techniques and guidance strategies are then shown with comments on the advantages and disadvantages of each one. The system consists of a standard electric wheelchair with an on-board computer, sensors and a graphic user interface run by the computer. On the other hand, this eye-control method can be applied to handle graphical interfaces, where the eye is used as a mouse computer. Results obtained show that this control technique could be useful in multiple applications, such as mobility and communication aid for handicapped persons.
Theoretical investigation of aberrations upon ametropic human eyes
NASA Astrophysics Data System (ADS)
Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin
2003-11-01
The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.
Vaez‐zadeh, Mehdi; Masoudi, S. Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S.
2015-01-01
The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry. PACS number: 87.53.Jw, 87.85.Rs, 87.10.Rt PMID:26699318
Morphologic analysis of artifacts in human fetal eyes confounding histopathologic investigations.
Herwig, Martina C; Müller, Annette M; Holz, Frank G; Loeffler, Karin U
2011-04-25
Human fetal eyes are an excellent source for studies of the normal ocular development and for examining early ocular changes associated with various syndromes in the context of a pediatric pathologic or prenatal sonographic diagnosis. However, artifacts caused by different factors often render an exact interpretation difficult. In this study, the frequency and extent of artifacts in human fetal eyes were investigated with the aim of distinguishing more precisely these artifacts from real findings, allowing also for a more diligent forensic interpretation. The cohort included 341 fetal eyes, ranging in age from 8 to 38 weeks of gestation, that were investigated macroscopically and by light microscopy. In most specimens, artifacts such as pigment spillage and autolytic changes of the retina were noted. Nearly all specimens showed changes of the lens with remarkable similarities to cataractous lenses in adult eyes. Structural ocular changes associated with systemic syndromes were also observed and in most instances could be distinguished from artifacts. Morphologic changes in fetal eyes should be classified in artifacts caused by way of abortion, mechanical effects from the removal of the eyes, delayed fixation with autolysis, and the fixative itself and should be distinguished from genuine structural abnormalities associated with ocular or systemic disease. This classification can be fairly difficult and requires experience. In addition, lens artifacts are often misleading, and the diagnosis of a fetal cataract should not be made based on histopathologic examination alone.
Learning rational temporal eye movement strategies.
Hoppe, David; Rothkopf, Constantin A
2016-07-19
During active behavior humans redirect their gaze several times every second within the visual environment. Where we look within static images is highly efficient, as quantified by computational models of human gaze shifts in visual search and face recognition tasks. However, when we shift gaze is mostly unknown despite its fundamental importance for survival in a dynamic world. It has been suggested that during naturalistic visuomotor behavior gaze deployment is coordinated with task-relevant events, often predictive of future events, and studies in sportsmen suggest that timing of eye movements is learned. Here we establish that humans efficiently learn to adjust the timing of eye movements in response to environmental regularities when monitoring locations in the visual scene to detect probabilistically occurring events. To detect the events humans adopt strategies that can be understood through a computational model that includes perceptual and acting uncertainties, a minimal processing time, and, crucially, the intrinsic costs of gaze behavior. Thus, subjects traded off event detection rate with behavioral costs of carrying out eye movements. Remarkably, based on this rational bounded actor model the time course of learning the gaze strategies is fully explained by an optimal Bayesian learner with humans' characteristic uncertainty in time estimation, the well-known scalar law of biological timing. Taken together, these findings establish that the human visual system is highly efficient in learning temporal regularities in the environment and that it can use these regularities to control the timing of eye movements to detect behaviorally relevant events.
Local synthesis of sex hormones: are there consequences for the ocular surface and dry eye?
Gibson, Emma J; Stapleton, Fiona; Wolffsohn, James S; Golebiowski, Blanka
2017-12-01
Sex hormones are associated with the physiology and pathophysiology of almost all organs in the body, as well as most diseases. Interest in the associations between sex hormones and ocular tissues has increased in recent years. Androgens may have a positive effect on dry eye, whereas the effects of oestrogen on ocular conditions remain unclear. Intracrinology, the local synthesis and metabolism of hormones that is unique to humans, is of relevance to the eye and may help to explain why studies of the relationship between oestrogens and dry eye signs and symptoms are inconclusive. Knowledge of the pathways of hormone formation and metabolism is crucial to understanding the pathogenesis of ocular disease including dry eye. This review examines the mechanisms of steroidal sex hormone biosynthesis and reviews the significance of locally produced sex hormones, with a focus on ocular surface tissues. Much of the current literature is based on animal studies, which may not be transferable to humans due to the absence of intracrine production in animals. A large proportion of the human studies investigate systemic hormone levels rather than local levels. There is subsequently a need for additional studies to provide a better understanding of the local production of sex hormones within the human eye and ocular surface and to clarify the relationships between ocular levels of sex hormones and conditions including dry eye. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Shinozaki, Takahiro
2018-01-01
Human-computer interface systems whose input is based on eye movements can serve as a means of communication for patients with locked-in syndrome. Eye-writing is one such system; users can input characters by moving their eyes to follow the lines of the strokes corresponding to characters. Although this input method makes it easy for patients to get started because of their familiarity with handwriting, existing eye-writing systems suffer from slow input rates because they require a pause between input characters to simplify the automatic recognition process. In this paper, we propose a continuous eye-writing recognition system that achieves a rapid input rate because it accepts characters eye-written continuously, with no pauses. For recognition purposes, the proposed system first detects eye movements using electrooculography (EOG), and then a hidden Markov model (HMM) is applied to model the EOG signals and recognize the eye-written characters. Additionally, this paper investigates an EOG adaptation that uses a deep neural network (DNN)-based HMM. Experiments with six participants showed an average input speed of 27.9 character/min using Japanese Katakana as the input target characters. A Katakana character-recognition error rate of only 5.0% was achieved using 13.8 minutes of adaptation data. PMID:29425248
Hypothesis on human eye perceiving optical spectrum rather than an image
NASA Astrophysics Data System (ADS)
Zheng, Yufeng; Szu, Harold
2015-05-01
It is a common knowledge that we see the world because our eyes can perceive an optical image. A digital camera seems a good example of simulating the eye imaging system. However, the signal sensing and imaging on human retina is very complicated. There are at least five layers (of neurons) along the signal pathway: photoreceptors (cones and rods), bipolar, horizontal, amacrine and ganglion cells. To sense an optical image, it seems that photoreceptors (as sensors) plus ganglion cells (converting to electrical signals for transmission) are good enough. Image sensing does not require ununiformed distribution of photoreceptors like fovea. There are some challenging questions, for example, why don't we feel the "blind spots" (never fibers exiting the eyes)? Similar situation happens to glaucoma patients who do not feel their vision loss until 50% or more nerves died. Now our hypothesis is that human retina initially senses optical (i.e., Fourier) spectrum rather than optical image. Due to the symmetric property of Fourier spectrum the signal loss from a blind spot or the dead nerves (for glaucoma patients) can be recovered. Eye logarithmic response to input light intensity much likes displaying Fourier magnitude. The optics and structures of human eyes satisfy the needs of optical Fourier spectrum sampling. It is unsure that where and how inverse Fourier transform is performed in human vision system to obtain an optical image. Phase retrieval technique in compressive sensing domain enables image reconstruction even without phase inputs. The spectrum-based imaging system can potentially tolerate up to 50% of bad sensors (pixels), adapt to large dynamic range (with logarithmic response), etc.
An automatic eye detection and tracking technique for stereo video sequences
NASA Astrophysics Data System (ADS)
Paduru, Anirudh; Charalampidis, Dimitrios; Fouts, Brandon; Jovanovich, Kim
2009-05-01
Human-computer interfacing (HCI) describes a system or process with which two information processors, namely a human and a computer, attempt to exchange information. Computer-to-human (CtH) information transfer has been relatively effective through visual displays and sound devices. On the other hand, the human-tocomputer (HtC) interfacing avenue has yet to reach its full potential. For instance, the most common HtC communication means are the keyboard and mouse, which are already becoming a bottleneck in the effective transfer of information. The solution to the problem is the development of algorithms that allow the computer to understand human intentions based on their facial expressions, head motion patterns, and speech. In this work, we are investigating the feasibility of a stereo system to effectively determine the head position, including the head rotation angles, based on the detection of eye pupils.
Negro, Juan J; Carmen Blázquez, M; Galván, Ismael
2017-01-01
Human populations and breeds of domestic animals are composed of individuals with a multiplicity of eye (= iris) colorations. Some wild birds and mammals may have intraspecific eye color variability, but this variation seems to be due to the developmental stage of the individual, its breeding status, and/or sexual dimorphism. In other words, eye colour tends to be a species-specific trait in wild animals, and the exceptions are species in which individuals of the same age group or gender all develop the same eye colour. Domestic animals, by definition, include bird and mammal species artificially selected by humans in the last few thousand years. Humans themselves may have acquired a diverse palette of eye colors, likewise in recent evolutionary time, in the Mesolithic or in the Upper Paleolithic. We posit two previously unrecognized hypotheses regarding eye color variation: 1) eye coloration in wild animals of every species tends to be a fixed trait. 2) Humans and domestic animal populations, on the contrary, have eyes of multiple colors. Sexual selection has been invoked for eye color variation in humans, but this selection mode does not easily apply in domestic animals, where matings are controlled by the human breeder. Eye coloration is polygenic in humans. We wish to investigate the genetics of eye color in other animals, as well as the ecological correlates. Investigating the origin and function of eye colors will shed light on the reason why some species may have either light-colored irises (e.g., white, yellow or light blue) or dark ones (dark red, brown or black). The causes behind the vast array of eye colors across taxa have never been thoroughly investigated, but it may well be that all Darwinian selection processes are at work: sexual selection in humans, artificial selection for domestic animals, and natural selection (mainly) for wild animals.
Dry Eye Disease and Microbial Keratitis: Is There a Connection?
Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.
2013-01-01
Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043
Modeling the influence of LASIK surgery on optical properties of the human eye
NASA Astrophysics Data System (ADS)
Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina
2011-11-01
The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.
Estimation of melanin content in iris of human eye: prognosis for glaucoma diagnostics
NASA Astrophysics Data System (ADS)
Bashkatov, Alexey N.; Koblova, Ekaterina V.; Genina, Elina A.; Kamenskikh, Tatyana G.; Dolotov, Leonid E.; Sinichkin, Yury P.; Tuchin, Valery V.
2007-02-01
Based on the experimental data obtained in vivo from digital analysis of color images of human irises, the mean melanin content in human eye irises has been estimated. For registration of the color images a digital camera Olympus C-5060 has been used. The images have been obtained from irises of healthy volunteers as well as from irises of patients with open-angle glaucoma. The computer program has been developed for digital analysis of the images. The result has been useful for development of novel and optimization of already existing methods of non-invasive glaucoma diagnostics.
Online Learners’ Reading Ability Detection Based on Eye-Tracking Sensors
Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S. W.
2016-01-01
The detection of university online learners’ reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners’ pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner’s reading ability. PMID:27626418
OCT angiography by absolute intensity difference applied to normal and diseased human retinas
Ruminski, Daniel; Sikorski, Bartosz L.; Bukowska, Danuta; Szkulmowski, Maciej; Krawiec, Krzysztof; Malukiewicz, Grazyna; Bieganowski, Lech; Wojtkowski, Maciej
2015-01-01
We compare four optical coherence tomography techniques for noninvasive visualization of microcapillary network in the human retina and murine cortex. We perform phantom studies to investigate contrast-to-noise ratio for angiographic images obtained with each of the algorithm. We show that the computationally simplest absolute intensity difference angiographic OCT algorithm that bases only on two cross-sectional intensity images may be successfully used in clinical study of healthy eyes and eyes with diabetic maculopathy and branch retinal vein occlusion. PMID:26309740
What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.
Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian
2013-10-01
Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.
Design of "Eye Closure" system for the stealth of photo-electric equipments
NASA Astrophysics Data System (ADS)
Zhang, Y.; Hua, W. S.; Li, G.
2012-10-01
Based on the optical activity of liquid crystal, a new approach for the stealth of "cat's eye" targets is proposed in this paper. It imitates the physiological close reaction of human eyes when strong light irradiates eyes. With this approach, the "cat's eye" effect will vanish, which is applied in restricting photo-electric equipments being detected and located by active laser detection system. The structure and working principle of the design are presented. The drive circuit is given to control the optical switch automatically. Feasibility of this design is demonstrated by experimental method. The measured data illustrate that the proposed approach is effective to eliminate the "cat's eye" effect, so as to enhancing the viability of photo-electric equipments on the battlefield.
da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos
2018-06-25
Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential. Copyright © 2018. Published by Elsevier B.V.
Fast cat-eye effect target recognition based on saliency extraction
NASA Astrophysics Data System (ADS)
Li, Li; Ren, Jianlin; Wang, Xingbin
2015-09-01
Background complexity is a main reason that results in false detection in cat-eye target recognition. Human vision has selective attention property which can help search the salient target from complex unknown scenes quickly and precisely. In the paper, we propose a novel cat-eye effect target recognition method named Multi-channel Saliency Processing before Fusion (MSPF). This method combines traditional cat-eye target recognition with the selective characters of visual attention. Furthermore, parallel processing enables it to achieve fast recognition. Experimental results show that the proposed method performs better in accuracy, robustness and speed compared to other methods.
Eye coding mechanisms in early human face event-related potentials.
Rousselet, Guillaume A; Ince, Robin A A; van Rijsbergen, Nicola J; Schyns, Philippe G
2014-11-10
In humans, the N170 event-related potential (ERP) is an integrated measure of cortical activity that varies in amplitude and latency across trials. Researchers often conjecture that N170 variations reflect cortical mechanisms of stimulus coding for recognition. Here, to settle the conjecture and understand cortical information processing mechanisms, we unraveled the coding function of N170 latency and amplitude variations in possibly the simplest socially important natural visual task: face detection. On each experimental trial, 16 observers saw face and noise pictures sparsely sampled with small Gaussian apertures. Reverse-correlation methods coupled with information theory revealed that the presence of the eye specifically covaries with behavioral and neural measurements: the left eye strongly modulates reaction times and lateral electrodes represent mainly the presence of the contralateral eye during the rising part of the N170, with maximum sensitivity before the N170 peak. Furthermore, single-trial N170 latencies code more about the presence of the contralateral eye than N170 amplitudes and early latencies are associated with faster reaction times. The absence of these effects in control images that did not contain a face refutes alternative accounts based on retinal biases or allocation of attention to the eye location on the face. We conclude that the rising part of the N170, roughly 120-170 ms post-stimulus, is a critical time-window in human face processing mechanisms, reflecting predominantly, in a face detection task, the encoding of a single feature: the contralateral eye. © 2014 ARVO.
Fast hierarchical knowledge-based approach for human face detection in color images
NASA Astrophysics Data System (ADS)
Jiang, Jun; Gong, Jie; Zhang, Guilin; Hu, Ruolan
2001-09-01
This paper presents a fast hierarchical knowledge-based approach for automatically detecting multi-scale upright faces in still color images. The approach consists of three levels. At the highest level, skin-like regions are determinated by skin model, which is based on the color attributes hue and saturation in HSV color space, as well color attributes red and green in normalized color space. In level 2, a new eye model is devised to select human face candidates in segmented skin-like regions. An important feature of the eye model is that it is independent of the scale of human face. So it is possible for finding human faces in different scale with scanning image only once, and it leads to reduction the computation time of face detection greatly. In level 3, a human face mosaic image model, which is consistent with physical structure features of human face well, is applied to judge whether there are face detects in human face candidate regions. This model includes edge and gray rules. Experiment results show that the approach has high robustness and fast speed. It has wide application perspective at human-computer interactions and visual telephone etc.
Rotational symmetric HMD with eye-tracking capability
NASA Astrophysics Data System (ADS)
Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian
2016-10-01
As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.
Structural Neural Substrates of Reading the Mind in the Eyes.
Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi
2016-01-01
The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.
P gene as an inherited biomarker of human eye color.
Rebbeck, Timothy R; Kanetsky, Peter A; Walker, Amy H; Holmes, Robin; Halpern, Allan C; Schuchter, Lynn M; Elder, David E; Guerry, DuPont
2002-08-01
Human pigmentation, including eye color, has been associated with skin cancer risk. The P gene is the human homologue to the mouse pink-eye dilution locus and is responsible for oculocutaneous albinism type 2 and other phenotypes that confer eye hypopigmentation. The P gene is located on chromosome 15q11.2-q12, which is also the location of a putative eye pigmentation gene (EYCL3) inferred to exist by linkage analysis. Therefore, the P gene is a strong candidate for determination of human eye color. Using a sample of 629 normally pigmented individuals, we found that individuals were less likely to have blue or gray eyes if they had P gene variants Arg305Trp (P = 0.002), Arg419Gln (P = 0.001), or the combination of both variants (P = 0.003). These results suggest that P gene, in part, determines normal phenotypic variation in human eye color and may therefore represent an inherited biomarker of cutaneous cancer risk.
Inhibition of copper-mediated aggregation of human γD-crystallin by Schiff bases.
Chauhan, Priyanka; Muralidharan, Sai Brinda; Velappan, Anand Babu; Datta, Dhrubajyoti; Pratihar, Sanjay; Debnath, Joy; Ghosh, Kalyan Sundar
2017-06-01
Protein aggregation, due to the imbalance in the concentration of Cu 2+ and Zn 2+ ions is found to be allied with various physiological disorders. Copper is known to promote the oxidative damage of β/γ-crystallins in aged eye lens and causes their aggregation leading to cataract. Therefore, synthesis of a small-molecule 'chelator' for Cu 2+ with complementary antioxidant effect will find potential applications against aggregation of β/γ-crystallins. In this paper, we have reported the synthesis of different Schiff bases and studied their Cu 2+ complexation ability (using UV-Vis, FT-IR and ESI-MS) and antioxidant activity. Further based on their copper complexation efficiency, Schiff bases were used to inhibit Cu 2+ -mediated aggregation of recombinant human γD-crystallin (HGD) and β/γ-crystallins (isolated from cataractous human eye lens). Among these synthesized molecules, compound 8 at a concentration of 100 μM had shown ~95% inhibition of copper (100 μM)-induced aggregation. Compound 8 also showed a positive cooperative effect at a concentration of 5-15 μM on the inhibitory activity of human αA-crystallin (HAA) during Cu 2+ -induced aggregation of HGD. It eventually inhibited the aggregation process by additional ~20%. However, ~50% inhibition of copper-mediated aggregation of β/γ-crystallins (isolated from cataractous human eye lens) was recorded by compound 8 (100 μM). Although the reductive aminated products of the imines showed better antioxidant activity due to their lower copper complexing ability, they were found to be non-effective against Cu 2+ -mediated aggregation of HGD.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-01
... establishments of which 145 are conventional tissue banks and 112 are eye tissue banks. Based on information...,115 donors of eye tissue each year. Accredited members of the American Association of Tissue Banks... system, 90 percent of the conventional tissue banks are members of AATB (145 x 90% = 130), and 77 percent...
2013-01-01
Background DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person’s externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Methods Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Results Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Conclusions Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals. PMID:23317428
Draus-Barini, Jolanta; Walsh, Susan; Pośpiech, Ewelina; Kupiec, Tomasz; Głąb, Henryk; Branicki, Wojciech; Kayser, Manfred
2013-01-14
DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person's externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals.
Pu, Xianjie; Guo, Hengyu; Chen, Jie; Wang, Xue; Xi, Yi; Hu, Chenguo; Wang, Zhong Lin
2017-07-01
Mechnosensational human-machine interfaces (HMIs) can greatly extend communication channels between human and external devices in a natural way. The mechnosensational HMIs based on biopotential signals have been developing slowly owing to the low signal-to-noise ratio and poor stability. In eye motions, the corneal-retinal potential caused by hyperpolarization and depolarization is very weak. However, the mechanical micromotion of the skin around the corners of eyes has never been considered as a good trigger signal source. We report a novel triboelectric nanogenerator (TENG)-based micromotion sensor enabled by the coupling of triboelectricity and electrostatic induction. By using an indium tin oxide electrode and two opposite tribomaterials, the proposed flexible and transparent sensor is capable of effectively capturing eye blink motion with a super-high signal level (~750 mV) compared with the traditional electrooculogram approach (~1 mV). The sensor is fixed on a pair of glasses and applied in two real-time mechnosensational HMIs-the smart home control system and the wireless hands-free typing system with advantages of super-high sensitivity, stability, easy operation, and low cost. This TENG-based micromotion sensor is distinct and unique in its fundamental mechanism, which provides a novel design concept for intelligent sensor technique and shows great potential application in mechnosensational HMIs.
Pu, Xianjie; Guo, Hengyu; Chen, Jie; Wang, Xue; Xi, Yi; Hu, Chenguo; Wang, Zhong Lin
2017-01-01
Mechnosensational human-machine interfaces (HMIs) can greatly extend communication channels between human and external devices in a natural way. The mechnosensational HMIs based on biopotential signals have been developing slowly owing to the low signal-to-noise ratio and poor stability. In eye motions, the corneal-retinal potential caused by hyperpolarization and depolarization is very weak. However, the mechanical micromotion of the skin around the corners of eyes has never been considered as a good trigger signal source. We report a novel triboelectric nanogenerator (TENG)–based micromotion sensor enabled by the coupling of triboelectricity and electrostatic induction. By using an indium tin oxide electrode and two opposite tribomaterials, the proposed flexible and transparent sensor is capable of effectively capturing eye blink motion with a super-high signal level (~750 mV) compared with the traditional electrooculogram approach (~1 mV). The sensor is fixed on a pair of glasses and applied in two real-time mechnosensational HMIs—the smart home control system and the wireless hands-free typing system with advantages of super-high sensitivity, stability, easy operation, and low cost. This TENG-based micromotion sensor is distinct and unique in its fundamental mechanism, which provides a novel design concept for intelligent sensor technique and shows great potential application in mechnosensational HMIs. PMID:28782029
NASA Astrophysics Data System (ADS)
Li, Qingyun; Karnowski, Karol; Villiger, Martin; Sampson, David D.
2017-04-01
A fibre-based full-range polarisation-sensitive optical coherence tomography system is developed to enable complete capture of the structural and birefringence properties of the anterior segment of the human eye in a single acquisition. The system uses a wavelength swept source centered at 1.3 μm, passively depth-encoded, orthogonal polarisation states in the illumination path and polarisation-diversity detection. Off-pivot galvanometer scanning is used to extend the imaging range and compensate for sensitivity drop-off. A Mueller matrix-based method is used to analyse data. We demonstrate the performance of the system and discuss issues relating to its optimisation.
ERIC Educational Resources Information Center
Koretz, Jane F.; Handelman, George H.
1988-01-01
Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)
NASA Astrophysics Data System (ADS)
Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.
2012-06-01
The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.
Comparison of eye imaging pattern recognition using neural network
NASA Astrophysics Data System (ADS)
Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.
2015-05-01
The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.
Photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)
1987-01-01
A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.
Multiconjugate adaptive optics applied to an anatomically accurate human eye model.
Bedggood, P A; Ashman, R; Smith, G; Metha, A B
2006-09-04
Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.
High-Speed Noninvasive Eye-Tracking System
NASA Technical Reports Server (NTRS)
Talukder, Ashit; LaBaw, Clayton; Michael-Morookian, John; Monacos, Steve; Serviss, Orin
2007-01-01
The figure schematically depicts a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. Like prior commercial noninvasive eye-tracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Relative to the prior commercial systems, the present system operates at much higher speed and thereby offers enhanced capability for applications that involve human-computer interactions, including typing and computer command and control by handicapped individuals,and eye-based diagnosis of physiological disorders that affect gaze responses.
Yamanari, Masahiro; Nagase, Satoko; Fukuda, Shinichi; Ishii, Kotaro; Tanaka, Ryosuke; Yasui, Takeshi; Oshika, Tetsuro; Miura, Masahiro; Yasuno, Yoshiaki
2014-05-01
The relationship between scleral birefringence and biometric parameters of human eyes in vivo is investigated. Scleral birefringence near the limbus of 21 healthy human eyes was measured using polarization-sensitive optical coherence tomography. Spherical equivalent refractive error, axial eye length, and intraocular pressure (IOP) were measured in all subjects. IOP and scleral birefringence of human eyes in vivo was found to have statistically significant correlations (r = -0.63, P = 0.002). The slope of linear regression was -2.4 × 10(-2) deg/μm/mmHg. Neither spherical equivalent refractive error nor axial eye length had significant correlations with scleral birefringence. To evaluate the direct influence of IOP to scleral birefringence, scleral birefringence of 16 ex vivo porcine eyes was measured under controlled IOP of 5-60 mmHg. In these ex vivo porcine eyes, the mean linear regression slope between controlled IOP and scleral birefringence was -9.9 × 10(-4) deg/μm/mmHg. In addition, porcine scleral collagen fibers were observed with second-harmonic-generation (SHG) microscopy. SHG images of porcine sclera, measured on the external surface at the superior side to the cornea, showed highly aligned collagen fibers parallel to the limbus. In conclusion, scleral birefringence of healthy human eyes was correlated with IOP, indicating that the ultrastructure of scleral collagen was correlated with IOP. It remains to show whether scleral collagen ultrastructure of human eyes is affected by IOP as a long-term effect.
A fiber optic sensor for ophthalmic refractive diagnostics
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Dhadwal, Harbans S.; Campbell, Melanie C. W.; Dellavecchia, Michael A.
1992-01-01
This paper demonstrates the application of a lensless fiber optic spectrometer (sensor) to study the onset of cataracts. This new miniaturized and rugged fiber optic probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for cold-induced cataract in excised bovine eye lenses, and aging effects in excised human eye lenses. The device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics.
Neural bases of eye and gaze processing: The core of social cognition
Itier, Roxane J.; Batty, Magali
2014-01-01
Eyes and gaze are very important stimuli for human social interactions. Recent studies suggest that impairments in recognizing face identity, facial emotions or in inferring attention and intentions of others could be linked to difficulties in extracting the relevant information from the eye region including gaze direction. In this review, we address the central role of eyes and gaze in social cognition. We start with behavioral data demonstrating the importance of the eye region and the impact of gaze on the most significant aspects of face processing. We review neuropsychological cases and data from various imaging techniques such as fMRI/PET and ERP/MEG, in an attempt to best describe the spatio-temporal networks underlying these processes. The existence of a neuronal eye detector mechanism is discussed as well as the links between eye gaze and social cognition impairments in autism. We suggest impairments in processing eyes and gaze may represent a core deficiency in several other brain pathologies and may be central to abnormal social cognition. PMID:19428496
High-speed adaptive optics line scan confocal retinal imaging for human eye.
Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.
Herwig, M C; Müller, A M; Holz, F G; Loeffler, K U
2010-11-01
Information on the evaluation of prenatal ocular findings is sparse. This article provides an overview of the morphology in a cohort of human fetal eyes, with particular emphasis on interesting findings. The study investigated 216 eyes from 115 human fetuses. The majority of fetal eyes presented with a regular phenotype. Rarely, unexpected findings were discovered in fetuses with or without systemic malformations. Routine evaluation of fetal eyes reveals-albeit rarely-new aspects providing further knowledge and occasionally enabling the exact classification of syndromes.
Three-dimensional ray tracing for refractive correction of human eye ametropies
NASA Astrophysics Data System (ADS)
Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.
2016-09-01
Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.
Characterization and Operation of Liquid Crystal Adaptive Optics Phoropter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Awwal, A; Bauman, B; Gavel, D
2003-02-05
Adaptive optics (AO), a mature technology developed for astronomy to compensate for the effects of atmospheric turbulence, can also be used to correct the aberrations of the eye. The classic phoropter is used by ophthalmologists and optometrists to estimate and correct the lower-order aberrations of the eye, defocus and astigmatism, in order to derive a vision correction prescription for their patients. An adaptive optics phoropter measures and corrects the aberrations in the human eye using adaptive optics techniques, which are capable of dealing with both the standard low-order aberrations and higher-order aberrations, including coma and spherical aberration. High-order aberrations havemore » been shown to degrade visual performance for clinical subjects in initial investigations. An adaptive optics phoropter has been designed and constructed based on a Shack-Hartmann sensor to measure the aberrations of the eye, and a liquid crystal spatial light modulator to compensate for them. This system should produce near diffraction-limited optical image quality at the retina, which will enable investigation of the psychophysical limits of human vision. This paper describes the characterization and operation of the AO phoropter with results from human subject testing.« less
Irsch, Kristina; Gramatikov, Boris; Wu, Yi-Kai; Guyton, David
2011-01-01
Utilizing the measured corneal birefringence from a data set of 150 eyes of 75 human subjects, an algorithm and related computer program, based on Müller-Stokes matrix calculus, were developed in MATLAB for assessing the influence of corneal birefringence on retinal birefringence scanning (RBS) and for converging upon an optical/mechanical design using wave plates (“wave-plate-enhanced RBS”) that allows foveal fixation detection essentially independently of corneal birefringence. The RBS computer model, and in particular the optimization algorithm, were verified with experimental human data using an available monocular RBS-based eye fixation monitor. Fixation detection using wave-plate-enhanced RBS is adaptable to less cooperative subjects, including young children at risk for developing amblyopia. PMID:21750772
Visual Positioning Indoors: Human Eyes vs. Smartphone Cameras
Wu, Dewen; Chen, Ruizhi; Chen, Liang
2017-01-01
Artificial Intelligence (AI) technologies and their related applications are now developing at a rapid pace. Indoor positioning will be one of the core technologies that enable AI applications because people spend 80% of their time indoors. Humans can locate themselves related to a visually well-defined object, e.g., a door, based on their visual observations. Can a smartphone camera do a similar job when it points to an object? In this paper, a visual positioning solution was developed based on a single image captured from a smartphone camera pointing to a well-defined object. The smartphone camera simulates the process of human eyes for the purpose of relatively locating themselves against a well-defined object. Extensive experiments were conducted with five types of smartphones on three different indoor settings, including a meeting room, a library, and a reading room. Experimental results shown that the average positioning accuracy of the solution based on five smartphone cameras is 30.6 cm, while that for the human-observed solution with 300 samples from 10 different people is 73.1 cm. PMID:29144420
Visual Positioning Indoors: Human Eyes vs. Smartphone Cameras.
Wu, Dewen; Chen, Ruizhi; Chen, Liang
2017-11-16
Artificial Intelligence (AI) technologies and their related applications are now developing at a rapid pace. Indoor positioning will be one of the core technologies that enable AI applications because people spend 80% of their time indoors. Humans can locate themselves related to a visually well-defined object, e.g., a door, based on their visual observations. Can a smartphone camera do a similar job when it points to an object? In this paper, a visual positioning solution was developed based on a single image captured from a smartphone camera pointing to a well-defined object. The smartphone camera simulates the process of human eyes for the purpose of relatively locating themselves against a well-defined object. Extensive experiments were conducted with five types of smartphones on three different indoor settings, including a meeting room, a library, and a reading room. Experimental results shown that the average positioning accuracy of the solution based on five smartphone cameras is 30.6 cm, while that for the human-observed solution with 300 samples from 10 different people is 73.1 cm.
The Human Engineering Eye Movement Measurement Research Facility.
1985-04-01
tracked reliably. When tracking is disrupted (e.g., by gross and sudden head movements, gross change in the head position, sneezing, prolonged eye...these are density ^\\ and " busyness " of the slides (stimulus material), as well as consistency . I„ between successive... change the material being projected based on the subject’s previous performance. The minicomputer relays the calibrated data to one of the magnetic
Iáñez, Eduardo; Azorin, Jose M.; Perez-Vidal, Carlos
2013-01-01
This paper describes a human-computer interface based on electro-oculography (EOG) that allows interaction with a computer using eye movement. The EOG registers the movement of the eye by measuring, through electrodes, the difference of potential between the cornea and the retina. A new pair of EOG glasses have been designed to improve the user's comfort and to remove the manual procedure of placing the EOG electrodes around the user's eye. The interface, which includes the EOG electrodes, uses a new processing algorithm that is able to detect the gaze direction and the blink of the eyes from the EOG signals. The system reliably enabled subjects to control the movement of a dot on a video screen. PMID:23843986
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lv, Yang; Wang, Ruixing; Ma, Haotong
Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides themore » aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.« less
Bio-inspired photon detection using chromophore/nanotube hybrids (Conference Presentation)
NASA Astrophysics Data System (ADS)
Léonard, François
2017-05-01
The human eye is an exquisite optical system with the ability to detect individual photons at room temperature. However, the complexity of this system, optimized over millions of years, has been difficult to reproduce using synthetic techniques. Here we discuss a bio-inspired approach for photon detection based on chromophore/nanotube hybrids, where the chromophore plays a similar role to the retinal molecule in the human eye, and the signal transduction is provided by electronic transport in the carbon nanotube. In this presentation, I will present the concept and discuss our progress in realizing this type of photodetection mechanism.
Towards Quantum Experiments with Human Eyes as Detectors Based on Cloning via Stimulated Emission
NASA Astrophysics Data System (ADS)
Sekatski, Pavel; Brunner, Nicolas; Branciard, Cyril; Gisin, Nicolas; Simon, Christoph
2009-09-01
We show theoretically that a large Bell inequality violation can be obtained with human eyes as detectors, in a “micro-macro” experiment where one photon from an entangled pair is greatly amplified via stimulated emission. The violation is robust under photon loss. This leads to an apparent paradox, which we resolve by noting that the violation proves the existence of entanglement before the amplification. The same is true for the micro-macro experiments performed so far with conventional detectors. However, we also prove that there is genuine micro-macro entanglement even for high loss.
Harmening, Wolf M; Tiruveedhula, Pavan; Roorda, Austin; Sincich, Lawrence C
2012-09-01
A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye's optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye's transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the technique against hyperacute psychophysical performance and the standard chromatic human eye model. In vivo correction of chromatic dispersion will enable confocal multi-wavelength images of the living retina to be aligned, and allow targeted chromatic stimulation of the photoreceptor mosaic to be performed accurately with sub-cellular resolution.
Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito
2017-09-01
Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Estimating outflow facility through pressure dependent pathways of the human eye
Gardiner, Bruce S.
2017-01-01
We develop and test a new theory for pressure dependent outflow from the eye. The theory comprises three main parameters: (i) a constant hydraulic conductivity, (ii) an exponential decay constant and (iii) a no-flow intraocular pressure, from which the total pressure dependent outflow, average outflow facilities and local outflow facilities for the whole eye may be evaluated. We use a new notation to specify precisely the meaning of model parameters and so model outputs. Drawing on a range of published data, we apply the theory to animal eyes, enucleated eyes and in vivo human eyes, and demonstrate how to evaluate model parameters. It is shown that the theory can fit high quality experimental data remarkably well. The new theory predicts that outflow facilities and total pressure dependent outflow for the whole eye are more than twice as large as estimates based on the Goldman equation and fluorometric analysis of anterior aqueous outflow. It appears likely that this discrepancy can be largely explained by pseudofacility and aqueous flow through the retinal pigmented epithelium, while any residual discrepancy may be due to pathological processes in aged eyes. The model predicts that if the hydraulic conductivity is too small, or the exponential decay constant is too large, then intraocular eye pressure may become unstable when subjected to normal circadian changes in aqueous production. The model also predicts relationships between variables that may be helpful when planning future experiments, and the model generates many novel testable hypotheses. With additional research, the analysis described here may find application in the differential diagnosis, prognosis and monitoring of glaucoma. PMID:29261696
Expert System Diagnosis of Cataract Eyes Using Fuzzy Mamdani Method
NASA Astrophysics Data System (ADS)
Santosa, I.; Romla, L.; Herawati, S.
2018-01-01
Cataracts are eye diseases characterized by cloudy or opacity of the lens of the eye by changing the colour of black into grey-white which slowly continues to grow and develop without feeling pain and pain that can cause blindness in human vision. Therefore, researchers make an expert system of cataract eye disease diagnosis by using Fuzzy Mamdani and how to care. The fuzzy method can convert the crisp value to linguistic value by fuzzification and includes in the rule. So this system produces an application program that can help the public in knowing cataract eye disease and how to care based on the symptoms suffered. From the results of the design implementation and testing of expert system applications to diagnose eye disease cataracts, it can be concluded that from a trial of 50 cases of data, obtained test results accuracy between system predictions with expert predictions obtained a value of 78% truth.
The Barrie Jones Lecture—Eye care for the neglected population: challenges and solutions
Rao, G N
2015-01-01
Globally, pockets of ‘neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of ‘Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people. PMID:25567375
Real-Time Detection and Measurement of Eye Features from Color Images
Borza, Diana; Darabant, Adrian Sergiu; Danescu, Radu
2016-01-01
The accurate extraction and measurement of eye features is crucial to a variety of domains, including human-computer interaction, biometry, and medical research. This paper presents a fast and accurate method for extracting multiple features around the eyes: the center of the pupil, the iris radius, and the external shape of the eye. These features are extracted using a multistage algorithm. On the first stage the pupil center is localized using a fast circular symmetry detector and the iris radius is computed using radial gradient projections, and on the second stage the external shape of the eye (of the eyelids) is determined through a Monte Carlo sampling framework based on both color and shape information. Extensive experiments performed on a different dataset demonstrate the effectiveness of our approach. In addition, this work provides eye annotation data for a publicly-available database. PMID:27438838
Chang, Won-Du; Cha, Ho-Seung; Im, Chang-Hwan
2016-01-01
This paper introduces a method to remove the unwanted interdependency between vertical and horizontal eye-movement components in electrooculograms (EOGs). EOGs have been widely used to estimate eye movements without a camera in a variety of human-computer interaction (HCI) applications using pairs of electrodes generally attached either above and below the eye (vertical EOG) or to the left and right of the eyes (horizontal EOG). It has been well documented that the vertical EOG component has less stability than the horizontal EOG one, making accurate estimation of the vertical location of the eyes difficult. To address this issue, an experiment was designed in which ten subjects participated. Visual inspection of the recorded EOG signals showed that the vertical EOG component is highly influenced by horizontal eye movements, whereas the horizontal EOG is rarely affected by vertical eye movements. Moreover, the results showed that this interdependency could be effectively removed by introducing an individual constant value. It is therefore expected that the proposed method can enhance the overall performance of practical EOG-based eye-tracking systems. PMID:26907271
Objective measurement of the optical image quality in the human eye
NASA Astrophysics Data System (ADS)
Navarro, Rafael M.
2001-05-01
This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid
In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less
Custom-oriented wavefront sensor for human eye properties measurements
NASA Astrophysics Data System (ADS)
Galetskiy, Sergey; Letfullin, Renat; Dubinin, Alex; Cherezova, Tatyana; Belyakov, Alexey; Kudryashov, Alexis
2005-12-01
The problem of correct measurement of human eye aberrations is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). In this paper we show capabilities to measure aberrations by means of the aberrometer built in our lab together with Active Optics Ltd. We discuss the calibration of the aberrometer and show invalidity to use for the ophthalmic calibration purposes the analytical equation based on thin lens formula. We show that proper analytical equation suitable for calibration should have dependence on the square of the distance increment and we illustrate this both by experiment and by Zemax Ray tracing modeling. Also the error caused by inhomogeneous intensity distribution of the beam imaged onto the aberrometer's Shack-Hartmann sensor is discussed.
Scanning mid-IR laser apparatus with eye tracking for refractive surgery
NASA Astrophysics Data System (ADS)
Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.
1999-06-01
A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.
Effect of Phenylephrine on the Accommodative System
Del Águila-Carrasco, Antonio J.; Bernal-Molina, Paula; Ferrer-Blasco, Teresa; López-Gil, Norberto; Montés-Micó, Robert
2016-01-01
Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephrine hydrochloride (PHCl) is a sympathomimetic agent that is used clinically to dilate the pupil. Nevertheless, first investigations suggested some loss of functional accommodation in the human eye after PHCl instillation. Subsequent studies, based on different measurement procedures, obtained contradictory conclusions, causing therefore an unexpected controversy that has been spread almost to the present days. This manuscript reviews and summarizes the main research studies that have been performed to analyze the effect of PHCl on the accommodative system and provides clear conclusions that could help clinicians know the real effects of PHCl on the accommodative system of the human eye. PMID:28053778
Optimal Eye-Gaze Fixation Position for Face-Related Neural Responses
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template. PMID:23762224
Optimal eye-gaze fixation position for face-related neural responses.
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template.
Li, Bin; Fu, Hong; Wen, Desheng; Lo, WaiLun
2018-05-19
Eye tracking technology has become increasingly important for psychological analysis, medical diagnosis, driver assistance systems, and many other applications. Various gaze-tracking models have been established by previous researchers. However, there is currently no near-eye display system with accurate gaze-tracking performance and a convenient user experience. In this paper, we constructed a complete prototype of the mobile gaze-tracking system ' Etracker ' with a near-eye viewing device for human gaze tracking. We proposed a combined gaze-tracking algorithm. In this algorithm, the convolutional neural network is used to remove blinking images and predict coarse gaze position, and then a geometric model is defined for accurate human gaze tracking. Moreover, we proposed using the mean value of gazes to resolve pupil center changes caused by nystagmus in calibration algorithms, so that an individual user only needs to calibrate it the first time, which makes our system more convenient. The experiments on gaze data from 26 participants show that the eye center detection accuracy is 98% and Etracker can provide an average gaze accuracy of 0.53° at a rate of 30⁻60 Hz.
Gaze-contingent displays: a review.
Duchowski, Andrew T; Cournia, Nathan; Murphy, Hunter
2004-12-01
Gaze-contingent displays (GCDs) attempt to balance the amount of information displayed against the visual information processing capacity of the observer through real-time eye movement sensing. Based on the assumed knowledge of the instantaneous location of the observer's focus of attention, GCD content can be "tuned" through several display processing means. Screen-based displays alter pixel level information generally matching the resolvability of the human retina in an effort to maximize bandwidth. Model-based displays alter geometric-level primitives along similar goals. Attentive user interfaces (AUIs) manage object- level entities (e.g., windows, applications) depending on the assumed attentive state of the observer. Such real-time display manipulation is generally achieved through non-contact, unobtrusive tracking of the observer's eye movements. This paper briefly reviews past and present display techniques as well as emerging graphics and eye tracking technology for GCD development.
Decoding Saccadic Directions Using Epidural ECoG in Non-Human Primates
2017-01-01
A brain-computer interface (BCI) can be used to restore some communication as an alternative interface for patients suffering from locked-in syndrome. However, most BCI systems are based on SSVEP, P300, or motor imagery, and a diversity of BCI protocols would be needed for various types of patients. In this paper, we trained the choice saccade (CS) task in 2 non-human primate monkeys and recorded the brain signal using an epidural electrocorticogram (eECoG) to predict eye movement direction. We successfully predicted the direction of the upcoming eye movement using a support vector machine (SVM) with the brain signals after the directional cue onset and before the saccade execution. The mean accuracies were 80% for 2 directions and 43% for 4 directions. We also quantified the spatial-spectro-temporal contribution ratio using SVM recursive feature elimination (RFE). The channels over the frontal eye field (FEF), supplementary eye field (SEF), and superior parietal lobule (SPL) area were dominantly used for classification. The α-band in the spectral domain and the time bins just after the directional cue onset and just before the saccadic execution were mainly useful for prediction. A saccade based BCI paradigm can be projected in the 2D space, and will hopefully provide an intuitive and convenient communication platform for users. PMID:28665058
NASA Astrophysics Data System (ADS)
Altıparmak, Hamit; Al Shahadat, Mohamad; Kiani, Ehsan; Dimililer, Kamil
2018-04-01
Robotic agriculture requires smart and doable techniques to substitute the human intelligence with machine intelligence. Strawberry is one of the important Mediterranean product and its productivity enhancement requires modern and machine-based methods. Whereas a human identifies the disease infected leaves by his eye, the machine should also be capable of vision-based disease identification. The objective of this paper is to practically verify the applicability of a new computer-vision method for discrimination between the healthy and disease infected strawberry leaves which does not require neural network or time consuming trainings. The proposed method was tested under outdoor lighting condition using a regular DLSR camera without any particular lens. Since the type and infection degree of disease is approximated a human brain a fuzzy decision maker classifies the leaves over the images captured on-site having the same properties of human vision. Optimizing the fuzzy parameters for a typical strawberry production area at a summer mid-day in Cyprus produced 96% accuracy for segmented iron deficiency and 93% accuracy for segmented using a typical human instant classification approximation as the benchmark holding higher accuracy than a human eye identifier. The fuzzy-base classifier provides approximate result for decision making on the leaf status as if it is healthy or not.
High-speed adaptive optics line scan confocal retinal imaging for human eye
Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458
Discrimination between smiling faces: Human observers vs. automated face analysis.
Del Líbano, Mario; Calvo, Manuel G; Fernández-Martín, Andrés; Recio, Guillermo
2018-05-11
This study investigated (a) how prototypical happy faces (with happy eyes and a smile) can be discriminated from blended expressions with a smile but non-happy eyes, depending on type and intensity of the eye expression; and (b) how smile discrimination differs for human perceivers versus automated face analysis, depending on affective valence and morphological facial features. Human observers categorized faces as happy or non-happy, or rated their valence. Automated analysis (FACET software) computed seven expressions (including joy/happiness) and 20 facial action units (AUs). Physical properties (low-level image statistics and visual saliency) of the face stimuli were controlled. Results revealed, first, that some blended expressions (especially, with angry eyes) had lower discrimination thresholds (i.e., they were identified as "non-happy" at lower non-happy eye intensities) than others (especially, with neutral eyes). Second, discrimination sensitivity was better for human perceivers than for automated FACET analysis. As an additional finding, affective valence predicted human discrimination performance, whereas morphological AUs predicted FACET discrimination. FACET can be a valid tool for categorizing prototypical expressions, but is currently more limited than human observers for discrimination of blended expressions. Configural processing facilitates detection of in/congruence(s) across regions, and thus detection of non-genuine smiling faces (due to non-happy eyes). Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.
2008-01-01
We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.
Binocular eye movement control and motion perception: what is being tracked?
van der Steen, Johannes; Dits, Joyce
2012-10-19
We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking.
Binocular Eye Movement Control and Motion Perception: What Is Being Tracked?
van der Steen, Johannes; Dits, Joyce
2012-01-01
Purpose. We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. Methods. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Results. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. Conclusions. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking. PMID:22997286
Plöchl, Michael; Ossandón, José P.; König, Peter
2012-01-01
Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source separation have been proposed. Yet, there is no automated standard procedure established. By simultaneously recording eye movements and 64-channel-EEG during a guided eye movement paradigm, we investigate and review the properties of eye movement artifacts, including corneo-retinal dipole changes, saccadic spike potentials and eyelid artifacts, and study their interrelations during different types of eye- and eyelid movements. In concordance with earlier studies our results confirm that these artifacts arise from different independent sources and that depending on electrode site, gaze direction, and choice of reference these sources contribute differently to the measured signal. We assess the respective implications for artifact correction methods and therefore compare the performance of two prominent approaches, namely linear regression and independent component analysis (ICA). We show and discuss that due to the independence of eye artifact sources, regression-based correction methods inevitably over- or under-correct individual artifact components, while ICA is in principle suited to address such mixtures of different types of artifacts. Finally, we propose an algorithm, which uses eye tracker information to objectively identify eye-artifact related ICA-components (ICs) in an automated manner. In the data presented here, the algorithm performed very similar to human experts when those were given both, the topographies of the ICs and their respective activations in a large amount of trials. Moreover it performed more reliable and almost twice as effective than human experts when those had to base their decision on IC topographies only. Furthermore, a receiver operating characteristic (ROC) analysis demonstrated an optimal balance of false positive and false negative at an area under curve (AUC) of more than 0.99. Removing the automatically detected ICs from the data resulted in removal or substantial suppression of ocular artifacts including microsaccadic spike potentials, while the relevant neural signal remained unaffected. In conclusion the present work aims at a better understanding of individual eye movement artifacts, their interrelations and the respective implications for eye artifact correction. Additionally, the proposed ICA-procedure provides a tool for optimized detection and correction of eye movement-related artifact components. PMID:23087632
Yang, Yushi
2015-01-01
Background Eye-tracking technology has been used to measure human cognitive processes and has the potential to improve the usability of health information technology (HIT). However, it is still unclear how the eye-tracking method can be integrated with other traditional usability methodologies to achieve its full potential. Objective The objective of this study was to report on HIT evaluation studies that have used eye-tracker technology, and to envision the potential use of eye-tracking technology in future research. Methods We used four reference databases to initially identify 5248 related papers, which resulted in only 9 articles that met our inclusion criteria. Results Eye-tracking technology was useful in finding usability problems in many ways, but is still in its infancy for HIT usability evaluation. Limited types of HITs have been evaluated by eye trackers, and there has been a lack of evaluation research in natural settings. Conclusions More research should be done in natural settings to discover the real contextual-based usability problems of clinical and mobile HITs using eye-tracking technology with more standardized methodologies and guidance. PMID:27026079
Ohuchi, Hideyo
2013-01-01
A central issue of evolutionary developmental biology is how the eye is diverged morphologically and functionally. However, the unifying mechanisms or schemes that govern eye diversification remain unsolved. In this review, I first introduce the concept of evolutionary developmental biology of the eye with a focus on photoreception, the fundamental property of retinal cells. Second, I summarize the early development of vertebrate eyes and the role of a homeobox gene, Lhx1, in subdivision of the retina into 2 domains, the neural retina and retinal pigmented epithelium of the optic primordium. The 2 retinal domains are essential components of the eye as they are found in such prototypic eyes as the extant planarian eye. Finally, I propose the presence of novel retinal cell subtypes with photosensory functions based on our recent work on atypical photopigments (opsins) in vertebrates. Since human diseases are attributable to the aberration of various types of cells due to alterations in gene expression, understanding the precise mechanisms of cellular diversification and unraveling the molecular profiles of cellular subtypes are essential to future regenerative medicine.
A PC-based software test for measuring alcohol and drug effects in human subjects.
Mills, K C; Parkman, K M; Spruill, S E
1996-12-01
A new software-based visual search and divided-attention test of cognitive performance was developed and evaluated in an alcohol dose-response study with 24 human subjects aged 21-62 years. The test used language-free, color, graphic displays to represent the visuospatial demands of driving. Cognitive demands were increased over previous hardware-based tests, and the motor skills required for the test involved minimal eye movements and eye-hand coordination. Repeated performance on the test was evaluated with a latin-square design by using a placebo and two alcohol doses, low (0.48 g/kg/LBM) and moderate (0.72 g/kg/LBM). The data on 7 females and 17 males yielded significant falling and rising impairment effects coincident with moderate rising and falling breath alcohol levels (mean peak BrALs = 0.045 g/dl and 0.079 g/dl). None of the subjects reported eye-strain or psychomotor fatigue as compared with previous tests. The high sensitivity/variance relative to use in basic and applied research, and worksite fitness-for-duty testing, was discussed. The most distinct advantage of a software-based test that operates on readily available PCs is that it can be widely distributed to researchers with a common reference to compare a variety of alcohol and drug effects.
Optical clearing of the eye using the See Deep Brain technique.
Hohberger, B; Baumgart, C; Bergua, A
2017-10-01
PurposeTissue clearing has been used in anatomy for the first time in Germany over a century ago. Neuronal tissue, like cortex, was investigated in mice using a water-based optical clearing method termed See Deep Brain (SeeDB). However, although the eye belongs to the central nervous system, this histological technique was not applied in the eye up to date. We applied SeeDB for the visualization of intraocular structures.Patients and methodsFour eyes of cornea donors (two male, two female: 73-84 years) obtained from the Cornea Bank of the Department of Ophthalmology Erlangen, four chicken eyes and two mices' optic nerve were used. Bulbi were fixed in 4% paraformaldehyde in phosphate-buffered saline and treated with increasing concentrations of aqueous fructose solution with 0.5% α-thioglycerol. After SeeDB, transscleral macrophotographs of the choroid were performed.ResultsComplete transparency of the sclera was obtained in enucleated human and chicken eyes after SeeDB treatment. Macroscopical anatomy of the choroid (partially transparent due to the remaining retinal pigment epithelium and melanocytes) showing vessels and other related structures was possible without preparing slides. Mice optic nerves were also transparent after SeeDB treatment.ConclusionThe SeeDB method allows visualization of intraocular structures through a completely translucent sclera. This innovative processing technique could facilitate comprehensive qualitative and quantitative topographical anatomical studies of human and animal eyes, preserving their 3D architecture. Supra- and intrachoroidal ganglionic plexus could potentially be visualized transsclerally. Finally, clinical-pathological correlations of intraocular diseases-for example, retinal tumors-will be possible in non-dissected eyes.
NASA Astrophysics Data System (ADS)
Hirtl, Rene; Schmid, Gernot
2013-09-01
A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.
Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.
Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo
2017-07-01
Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.
Levitt, Joshua; Nitenson, Adam; Koyama, Suguru; Heijmans, Lonne; Curry, James; Ross, Jason T; Kamerling, Steven; Saab, Carl Y
2018-06-23
Electroencephalography (EEG) invariably contains extra-cranial artifacts that are commonly dealt with based on qualitative and subjective criteria. Failure to account for EEG artifacts compromises data interpretation. We have developed a quantitative and automated support vector machine (SVM)-based algorithm to accurately classify artifactual EEG epochs in awake rodent, canine and humans subjects. An embodiment of this method also enables the determination of 'eyes open/closed' states in human subjects. The levels of SVM accuracy for artifact classification in humans, Sprague Dawley rats and beagle dogs were 94.17%, 83.68%, and 85.37%, respectively, whereas 'eyes open/closed' states in humans were labeled with 88.60% accuracy. Each of these results was significantly higher than chance. Comparison with Existing Methods: Other existing methods, like those dependent on Independent Component Analysis, have not been tested in non-human subjects, and require full EEG montages, instead of only single channels, as this method does. We conclude that our EEG artifact detection algorithm provides a valid and practical solution to a common problem in the quantitative analysis and assessment of EEG in pre-clinical research settings across evolutionary spectra. Copyright © 2018. Published by Elsevier B.V.
Eye movement-invariant representations in the human visual system.
Nishimoto, Shinji; Huth, Alexander G; Bilenko, Natalia Y; Gallant, Jack L
2017-01-01
During natural vision, humans make frequent eye movements but perceive a stable visual world. It is therefore likely that the human visual system contains representations of the visual world that are invariant to eye movements. Here we present an experiment designed to identify visual areas that might contain eye-movement-invariant representations. We used functional MRI to record brain activity from four human subjects who watched natural movies. In one condition subjects were required to fixate steadily, and in the other they were allowed to freely make voluntary eye movements. The movies used in each condition were identical. We reasoned that the brain activity recorded in a visual area that is invariant to eye movement should be similar under fixation and free viewing conditions. In contrast, activity in a visual area that is sensitive to eye movement should differ between fixation and free viewing. We therefore measured the similarity of brain activity across repeated presentations of the same movie within the fixation condition, and separately between the fixation and free viewing conditions. The ratio of these measures was used to determine which brain areas are most likely to contain eye movement-invariant representations. We found that voxels located in early visual areas are strongly affected by eye movements, while voxels in ventral temporal areas are only weakly affected by eye movements. These results suggest that the ventral temporal visual areas contain a stable representation of the visual world that is invariant to eye movements made during natural vision.
Theory and simulent design of a type of auto-self-protecting optical switches
NASA Astrophysics Data System (ADS)
Li, Binhong; Peng, Songcun
1990-06-01
As the use of lasers in the military and in the civilian economy increases with each passing day, it is often necessary for the human eye or sensitive instruments to observe weak lasers, such as the return waves of laser radar and laser communications signals; but it is also necessary to provide protection against damage to the eye from the strong lasers of enemy laser weapons. For this reason, it is necessary to have a kind of automatic optical self-protecting switch. Based upon a study of the transmitting and scattering characteristics of multilayer dielectric optical waveguides, a practical computer program is set up for designing a type of auto-self-protecting optical switch with a computer model by using the nonlinear property of dielectric layers and the plasma behavior of metal substrates. This technique can be used to protect the human eye and sensitive detectors from damage caused by strong laser beams.
NASA Astrophysics Data System (ADS)
Donnelly, William J., III
2012-06-01
PURPOSE: To present a commercially available optical modeling software tool to assist the development of optical instrumentation and systems that utilize and/or integrate with the human eye. METHODS: A commercially available flexible eye modeling system is presented, the Advanced Human Eye Model (AHEM). AHEM is a module that the engineer can use to perform rapid development and test scenarios on systems that integrate with the eye. Methods include merging modeled systems initially developed outside of AHEM and performing a series of wizard-type operations that relieve the user from requiring an optometric or ophthalmic background to produce a complete eye inclusive system. Scenarios consist of retinal imaging of targets and sources through integrated systems. Uses include, but are not limited to, optimization, telescopes, microscopes, spectacles, contact and intraocular lenses, ocular aberrations, cataract simulation and scattering, and twin eye model (binocular) systems. RESULTS: Metrics, graphical data, and exportable CAD geometry are generated from the various modeling scenarios.
Doi, Takahiro; Fujita, Ichiro
2014-01-01
Three-dimensional visual perception requires correct matching of images projected to the left and right eyes. The matching process is faced with an ambiguity: part of one eye's image can be matched to multiple parts of the other eye's image. This stereo correspondence problem is complicated for random-dot stereograms (RDSs), because dots with an identical appearance produce numerous potential matches. Despite such complexity, human subjects can perceive a coherent depth structure. A coherent solution to the correspondence problem does not exist for anticorrelated RDSs (aRDSs), in which luminance contrast is reversed in one eye. Neurons in the visual cortex reduce disparity selectivity for aRDSs progressively along the visual processing hierarchy. A disparity-energy model followed by threshold nonlinearity (threshold energy model) can account for this reduction, providing a possible mechanism for the neural matching process. However, the essential computation underlying the threshold energy model is not clear. Here, we propose that a nonlinear modification of cross-correlation, which we term “cross-matching,” represents the essence of the threshold energy model. We placed half-wave rectification within the cross-correlation of the left-eye and right-eye images. The disparity tuning derived from cross-matching was attenuated for aRDSs. We simulated a psychometric curve as a function of graded anticorrelation (graded mixture of aRDS and normal RDS); this simulated curve reproduced the match-based psychometric function observed in human near/far discrimination. The dot density was 25% for both simulation and observation. We predicted that as the dot density increased, the performance for aRDSs should decrease below chance (i.e., reversed depth), and the level of anticorrelation that nullifies depth perception should also decrease. We suggest that cross-matching serves as a simple computation underlying the match-based disparity signals in stereoscopic depth perception. PMID:25360107
NASA Astrophysics Data System (ADS)
1985-01-01
A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.
Integrating a Motion Base into a CAVE Automatic Virtual Environment: Phase 1
2001-07-01
this, a CAVE system must perform well in the following motion-related areas: visual gaze stability, simulator sickness, realism (or face validity...and performance validity. Visual Gaze Stability Visual gaze stability, the ability to maintain eye fixation on a particular target, depends upon human...reflexes such as the vestibulo-ocular reflex (VOR) and the optokinetic nystagmus (OKN). VOR is a reflex that counter-rotates the eye relative to the
NASA Astrophysics Data System (ADS)
Kriegerowski, Martin; Rassmann, Katja; Oltrup, Theo; Bende, Thomas; Jean, Benedikt J.
1995-05-01
The refractive outcome of thermokeratoplasty depends upon the location and angle of the coagulation spots, applied with a focusing handpiece onto the corneal surface. Accuracy can be enhanced using a specially designed application mask. An astigmatism correction was performed on 10 human donor eyes (Holmium 25, Technomed, FRG, 15 Hz, 20 mJ/pulse, 25 pulses) with an optical zone of 8.1 mm, 5 eyes received a free hand laser application (marked positions) and the other 5 eyes were treated using a suctioned metal mask with drills for the handpiece (optical zone 8.1 mm). To compare the results a silicone replica was taken and analyzed by a confocal laser microtopometer. The refractive change for the steepest meridian was 10 D with a standard deviation of +/- 3.7 D for the free hand application. Using the application mask the refractive outcome was 9.8 D with a standard deviation of only 0.8 D. Using the application mask the standard deviation for the induced refractive change decreases by a factor of five.
Priorities and trends in the study of proteins in eye research, 1924–2014
Semba, Richard D.; Lam, Maggie; Sun, Kai; Zhang, Pingbo; Schaumberg, Debra A.; Ferrucci, Luigi; Ping, Peipei; Van Eyk, Jennifer E.
2015-01-01
Purpose To identify the proteins that are relevant to eye research and develop assays for the study of a set of these proteins. Experimental Design We conducted a bibliometric analysis by merging gene lists for human and mouse from the National Center for Biotechnology Information FTP site and combining them with PubMed references that were retrieved with the search terms “eye”[MeSH Terms] OR “eye”[All Fields] OR “eyes”[All Fields]. Results For human and mouse eye studies, respectively, the total number of publications was 13,525 and 23,895, and the total number of proteins was 4,050 and 4,717. For proteins in human and mouse eye studies, respectively, 88.7% and 81.7% had five or fewer citations. The top fifty most intensively studied proteins for human and mouse eye studies were generally in the areas of photoreceptors and phototransduction, inflammation and angiogenesis, neurodevelopment, lens transparency, and cell cycle and cellular processes. We proposed selected reaction monitoring assays that were developed in silico for the top fifty most intensively studied proteins in human and mouse eye research. Conclusions and clinical relevance We conclude that scientists engaged in eye research tend to focus on the same proteins. Newer resources and tools in proteomics can expand the investigations to lesser-known proteins of the eye. PMID:26123431
Behrens, R
2013-07-01
In this work, conversion coefficients from electron fluence to absorbed dose to the eye lens were calculated using Monte Carlo simulations based on a detailed stylised eye model and a very simple but whole body phantom. These data supersede and complement data published earlier based on the simulation of only a single stylised eye. The new data differ from the old ones by not more than 3, 4, 7 and 16 % for angles of radiation incidence of α=0°, 15°, 30° and 45°, respectively, due to the inclusion of the whole body phantom. The data presented in the present work also complement those of a recent report of the International Commission on Radiological Protection (ICRP) (ICRP Publication 116), where conversion coefficients from electron fluence to absorbed dose to the lens of the eye are shown for solely 0°, 180° and isotropic radiation incidence (but for a much broader range of energies). In this article, values are provided for angles of incidence of 0° up to 180° in steps of 15° and for rotational geometry; no systematic deviation was observed from the values given in ICRP Publication 116 for 0° (based on the application of a bare eye) and 180° (based on the application of a voxel whole body phantom). Data are given for monoenergetic electrons from 0.1 up to 10 MeV and for a broad parallel beam geometry in vacuum.
Evaluating the efficacy of fully automated approaches for the selection of eye blink ICA components
Pontifex, Matthew B.; Miskovic, Vladimir; Laszlo, Sarah
2017-01-01
Independent component analysis (ICA) offers a powerful approach for the isolation and removal of eye blink artifacts from EEG signals. Manual identification of the eye blink ICA component by inspection of scalp map projections, however, is prone to error, particularly when non-artifactual components exhibit topographic distributions similar to the blink. The aim of the present investigation was to determine the extent to which automated approaches for selecting eye blink related ICA components could be utilized to replace manual selection. We evaluated popular blink selection methods relying on spatial features [EyeCatch()], combined stereotypical spatial and temporal features [ADJUST()], and a novel method relying on time-series features alone [icablinkmetrics()] using both simulated and real EEG data. The results of this investigation suggest that all three methods of automatic component selection are able to accurately identify eye blink related ICA components at or above the level of trained human observers. However, icablinkmetrics(), in particular, appears to provide an effective means of automating ICA artifact rejection while at the same time eliminating human errors inevitable during manual component selection and false positive component identifications common in other automated approaches. Based upon these findings, best practices for 1) identifying artifactual components via automated means and 2) reducing the accidental removal of signal-related ICA components are discussed. PMID:28191627
Image processing and analysis using neural networks for optometry area
NASA Astrophysics Data System (ADS)
Netto, Antonio V.; Ferreira de Oliveira, Maria C.
2002-11-01
In this work we describe the framework of a functional system for processing and analyzing images of the human eye acquired by the Hartmann-Shack technique (HS), in order to extract information to formulate a diagnosis of eye refractive errors (astigmatism, hypermetropia and myopia). The analysis is to be carried out using an Artificial Intelligence system based on Neural Nets, Fuzzy Logic and Classifier Combination. The major goal is to establish the basis of a new technology to effectively measure ocular refractive errors that is based on methods alternative those adopted in current patented systems. Moreover, analysis of images acquired with the Hartmann-Shack technique may enable the extraction of additional information on the health of an eye under exam from the same image used to detect refraction errors.
Nakajima, Masashi; Hiraoka, Takahiro; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi
2015-01-01
Several researchers studied the longitudinal chromatic aberration (LCA) of the human eye and observed that it does not change due to age. We measured the LCA of 45 subjects’ normal right eyes at three distinct wavelengths (561, 690, and 840 nm) using a Hartmann–Shack wavefront aberrometer (HSWA) while consecutively switching between three light sources for wavefront sensing. We confirmed that the LCA of the human eye does not change due to age between 22 and 57 years. PMID:26203391
A Theoretical Analysis of a New Polarimetric Optical Scheme for Glucose Sensing in the Human Eye
NASA Technical Reports Server (NTRS)
Rovati, Luigi L.; Boeckle, Stefan; Ansari, Rafat R.; Salzman, Jack A. (Technical Monitor)
2002-01-01
The challenging task of in vivo polarimetric glucose sensing is the identification and selection of a scheme to optically access the aqueous humor of the human eye. In this short communication an earlier approach of Cote et al. is theoretically compared with our new optical scheme. Simulations of the new scheme using the eye model of Navarro, suggest that the new optical geometry can overcome the limitations of the previous approach for in vivo measurements of glucose in a human eye.
Bio-inspired hemispherical compound eye camera
NASA Astrophysics Data System (ADS)
Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.
2014-03-01
Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).
Human Values in a Secular World.
ERIC Educational Resources Information Center
Apostol, Robert Z.
The lectures of five contemporary philosophers, charged with addressing themselves to important moral issues of contemporary society with an eye to highlighting those values that are at the base of human life today, are presented in this volume. Louis Dupre is concerned with the issue of making religion intelligible in Religion in a Secular World.…
Walsh, Susan; Chaitanya, Lakshmi; Clarisse, Lindy; Wirken, Laura; Draus-Barini, Jolanta; Kovatsi, Leda; Maeda, Hitoshi; Ishikawa, Takaki; Sijen, Titia; de Knijff, Peter; Branicki, Wojciech; Liu, Fan; Kayser, Manfred
2014-03-01
Forensic DNA Phenotyping or 'DNA intelligence' tools are expected to aid police investigations and find unknown individuals by providing information on externally visible characteristics of unknown suspects, perpetrators and missing persons from biological samples. This is especially useful in cases where conventional DNA profiling or other means remain non-informative. Recently, we introduced the HIrisPlex system, capable of predicting both eye and hair colour from DNA. In the present developmental validation study, we demonstrate that the HIrisPlex assay performs in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines providing an essential prerequisite for future HIrisPlex applications to forensic casework. The HIrisPlex assay produces complete profiles down to only 63 pg of DNA. Species testing revealed human specificity for a complete HIrisPlex profile, while only non-human primates showed the closest full profile at 20 out of the 24 DNA markers, in all animals tested. Rigorous testing of simulated forensic casework samples such as blood, semen, saliva stains, hairs with roots as well as extremely low quantity touch (trace) DNA samples, produced complete profiles in 88% of cases. Concordance testing performed between five independent forensic laboratories displayed consistent reproducible results on varying types of DNA samples. Due to its design, the assay caters for degraded samples, underlined here by results from artificially degraded DNA and from simulated casework samples of degraded DNA. This aspect was also demonstrated previously on DNA samples from human remains up to several hundreds of years old. With this paper, we also introduce enhanced eye and hair colour prediction models based on enlarged underlying databases of HIrisPlex genotypes and eye/hair colour phenotypes (eye colour: N = 9188 and hair colour: N = 1601). Furthermore, we present an online web-based system for individual eye and hair colour prediction from full and partial HIrisPlex DNA profiles. By demonstrating that the HIrisPlex assay is fully compatible with the SWGDAM guidelines, we provide the first forensically validated DNA test system for parallel eye and hair colour prediction now available to forensic laboratories for immediate casework application, including missing person cases. Given the robustness and sensitivity described here and in previous work, the HIrisPlex system is also suitable for analysing old and ancient DNA in anthropological and evolutionary studies. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Method of Menu Selection by Gaze Movement Using AC EOG Signals
NASA Astrophysics Data System (ADS)
Kanoh, Shin'ichiro; Futami, Ryoko; Yoshinobu, Tatsuo; Hoshimiya, Nozomu
A method to detect the direction and the distance of voluntary eye gaze movement from EOG (electrooculogram) signals was proposed and tested. In this method, AC-amplified vertical and horizontal transient EOG signals were classified into 8-class directions and 2-class distances of voluntary eye gaze movements. A horizontal and a vertical EOGs during eye gaze movement at each sampling time were treated as a two-dimensional vector, and the center of gravity of the sample vectors whose norms were more than 80% of the maximum norm was used as a feature vector to be classified. By the classification using the k-nearest neighbor algorithm, it was shown that the averaged correct detection rates on each subject were 98.9%, 98.7%, 94.4%, respectively. This method can avoid strict EOG-based eye tracking which requires DC amplification of very small signal. It would be useful to develop robust human interfacing systems based on menu selection for severely paralyzed patients.
Ma, Jiaxin; Zhang, Yu; Cichocki, Andrzej; Matsuno, Fumitoshi
2015-03-01
This study presents a novel human-machine interface (HMI) based on both electrooculography (EOG) and electroencephalography (EEG). This hybrid interface works in two modes: an EOG mode recognizes eye movements such as blinks, and an EEG mode detects event related potentials (ERPs) like P300. While both eye movements and ERPs have been separately used for implementing assistive interfaces, which help patients with motor disabilities in performing daily tasks, the proposed hybrid interface integrates them together. In this way, both the eye movements and ERPs complement each other. Therefore, it can provide a better efficiency and a wider scope of application. In this study, we design a threshold algorithm that can recognize four kinds of eye movements including blink, wink, gaze, and frown. In addition, an oddball paradigm with stimuli of inverted faces is used to evoke multiple ERP components including P300, N170, and VPP. To verify the effectiveness of the proposed system, two different online experiments are carried out. One is to control a multifunctional humanoid robot, and the other is to control four mobile robots. In both experiments, the subjects can complete tasks effectively by using the proposed interface, whereas the best completion time is relatively short and very close to the one operated by hand.
NASA Astrophysics Data System (ADS)
Iomdina, Elena N.; Goltsman, Gregory N.; Seliverstov, Sergey V.; Sianosyan, Alisa A.; Teplyakova, Kseniya O.; Rusova, Anastasia A.
2016-09-01
An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Alternative Indices of Performance: An Exploration of Eye Gaze Metrics in a Visual Puzzle Task
2014-07-01
strategy in which participants anchor their search on pieces in the correct positions results. Although there were significant effects for both...PERFORMANCE WING, HUMAN EFFECTIVENESS DIRECTORATE, WRIGHT-PATTERSON AIR FORCE BASE, OH 45433 AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE...Interface Division //signed// WILLIAM E. RUSSELL Chief, Warfighter Interface Division Human Effectiveness Directorate 711 Human Performance
Cortexin diffusion in human eye sclera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V
2011-05-31
Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCTmore » signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)« less
Optical eye simulator for laser dazzle events.
Coelho, João M P; Freitas, José; Williamson, Craig A
2016-03-20
An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.
Human eye haptics-based multimedia.
Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron
2014-01-01
Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.
Mayhew, Jessica A; Gómez, Juan-Carlos
2015-08-01
Human eye morphology is considered unique among the primates in that humans possess larger width/height ratios (WHR), expose a greater amount of visible sclera (SSI; width of exposed eyeball/width of visible iris), and critically, have a white sclera due to a lack of pigmentation. White sclera in humans amplifies gaze direction, whereas the all-dark eyes of apes are hypothesized to conceal gaze from others. This study examines WHR and SSI in humans (N = 13) and gorillas (N = 85) engaged in direct and averted gazes and introduces a qualitative assessment of sclera color to evaluate variations in sclera pigmentation. The results confirm previous findings that humans possess a larger WHR than gorillas but indicate that humans and gorillas display similar amounts of visible sclera. Additionally, 72% (N = 124) of gorilla eyes in this sample deviated from the assumed all-dark eye condition. This questions whether gaze camouflage is the primary function of darkened sclera in non-human primates or whether other functional roles can be ascribed to the sclera, light or dark. We argue that white sclera evolved to amplify direct gazes in humans, which would have played a significant role in the development of ostensive communication, which is communication that both shows something and shows the intention to show something. We conclude that the horizontal elongation of the human eye, rather than sclera color, more reliably distinguishes human from great ape eyes, represented here by gorillas. © 2015 Wiley Periodicals, Inc.
Sesin, Anaelis; Adjouadi, Malek; Cabrerizo, Mercedes; Ayala, Melvin; Barreto, Armando
2008-01-01
This study developed an adaptive real-time human-computer interface (HCI) that serves as an assistive technology tool for people with severe motor disability. The proposed HCI design uses eye gaze as the primary computer input device. Controlling the mouse cursor with raw eye coordinates results in sporadic motion of the pointer because of the saccadic nature of the eye. Even though eye movements are subtle and completely imperceptible under normal circumstances, they considerably affect the accuracy of an eye-gaze-based HCI. The proposed HCI system is novel because it adapts to each specific user's different and potentially changing jitter characteristics through the configuration and training of an artificial neural network (ANN) that is structured to minimize the mouse jitter. This task is based on feeding the ANN a user's initially recorded eye-gaze behavior through a short training session. The ANN finds the relationship between the gaze coordinates and the mouse cursor position based on the multilayer perceptron model. An embedded graphical interface is used during the training session to generate user profiles that make up these unique ANN configurations. The results with 12 subjects in test 1, which involved following a moving target, showed an average jitter reduction of 35%; the results with 9 subjects in test 2, which involved following the contour of a square object, showed an average jitter reduction of 53%. For both results, the outcomes led to trajectories that were significantly smoother and apt at reaching fixed or moving targets with relative ease and within a 5% error margin or deviation from desired trajectories. The positive effects of such jitter reduction are presented graphically for visual appreciation.
Learning-based saliency model with depth information.
Ma, Chih-Yao; Hang, Hsueh-Ming
2015-01-01
Most previous studies on visual saliency focused on two-dimensional (2D) scenes. Due to the rapidly growing three-dimensional (3D) video applications, it is very desirable to know how depth information affects human visual attention. In this study, we first conducted eye-fixation experiments on 3D images. Our fixation data set comprises 475 3D images and 16 subjects. We used a Tobii TX300 eye tracker (Tobii, Stockholm, Sweden) to track the eye movement of each subject. In addition, this database contains 475 computed depth maps. Due to the scarcity of public-domain 3D fixation data, this data set should be useful to the 3D visual attention research community. Then, a learning-based visual attention model was designed to predict human attention. In addition to the popular 2D features, we included the depth map and its derived features. The results indicate that the extra depth information can enhance the saliency estimation accuracy specifically for close-up objects hidden in a complex-texture background. In addition, we examined the effectiveness of various low-, mid-, and high-level features on saliency prediction. Compared with both 2D and 3D state-of-the-art saliency estimation models, our methods show better performance on the 3D test images. The eye-tracking database and the MATLAB source codes for the proposed saliency model and evaluation methods are available on our website.
Decoding Saccadic Directions Using Epidural ECoG in Non-Human Primates.
Lee, Jeyeon; Choi, Hoseok; Lee, Seho; Cho, Baek Hwan; Ahn, Kyoung Ha; Kim, In Young; Lee, Kyoung Min; Jang, Dong Pyo
2017-08-01
A brain-computer interface (BCI) can be used to restore some communication as an alternative interface for patients suffering from locked-in syndrome. However, most BCI systems are based on SSVEP, P300, or motor imagery, and a diversity of BCI protocols would be needed for various types of patients. In this paper, we trained the choice saccade (CS) task in 2 non-human primate monkeys and recorded the brain signal using an epidural electrocorticogram (eECoG) to predict eye movement direction. We successfully predicted the direction of the upcoming eye movement using a support vector machine (SVM) with the brain signals after the directional cue onset and before the saccade execution. The mean accuracies were 80% for 2 directions and 43% for 4 directions. We also quantified the spatial-spectro-temporal contribution ratio using SVM recursive feature elimination (RFE). The channels over the frontal eye field (FEF), supplementary eye field (SEF), and superior parietal lobule (SPL) area were dominantly used for classification. The α-band in the spectral domain and the time bins just after the directional cue onset and just before the saccadic execution were mainly useful for prediction. A saccade based BCI paradigm can be projected in the 2D space, and will hopefully provide an intuitive and convenient communication platform for users. © 2017 The Korean Academy of Medical Sciences.
Harrison, Charlotte; Jackson, Jade; Oh, Seung-Mock; Zeringyte, Vaida
2016-01-01
Multivariate pattern analysis of functional magnetic resonance imaging (fMRI) data is widely used, yet the spatial scales and origin of neurovascular signals underlying such analyses remain unclear. We compared decoding performance for stimulus orientation and eye of origin from fMRI measurements in human visual cortex with predictions based on the columnar organization of each feature and estimated the spatial scales of patterns driving decoding. Both orientation and eye of origin could be decoded significantly above chance in early visual areas (V1–V3). Contrary to predictions based on a columnar origin of response biases, decoding performance for eye of origin in V2 and V3 was not significantly lower than that in V1, nor did decoding performance for orientation and eye of origin differ significantly. Instead, response biases for both features showed large-scale organization, evident as a radial bias for orientation, and a nasotemporal bias for eye preference. To determine whether these patterns could drive classification, we quantified the effect on classification performance of binning voxels according to visual field position. Consistent with large-scale biases driving classification, binning by polar angle yielded significantly better decoding performance for orientation than random binning in V1–V3. Similarly, binning by hemifield significantly improved decoding performance for eye of origin. Patterns of orientation and eye preference bias in V2 and V3 showed a substantial degree of spatial correlation with the corresponding patterns in V1, suggesting that response biases in these areas originate in V1. Together, these findings indicate that multivariate classification results need not reflect the underlying columnar organization of neuronal response selectivities in early visual areas. NEW & NOTEWORTHY Large-scale response biases can account for decoding of orientation and eye of origin in human early visual areas V1–V3. For eye of origin this pattern is a nasotemporal bias; for orientation it is a radial bias. Differences in decoding performance across areas and stimulus features are not well predicted by differences in columnar-scale organization of each feature. Large-scale biases in extrastriate areas are spatially correlated with those in V1, suggesting biases originate in primary visual cortex. PMID:27903637
Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki
2013-07-01
The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.
Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, Casey Robert; Rice, Brandon Charles; Bower, Gordon Ross
Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.
Dog Breed Differences in Visual Communication with Humans.
Konno, Akitsugu; Romero, Teresa; Inoue-Murayama, Miho; Saito, Atsuko; Hasegawa, Toshikazu
2016-01-01
Domestic dogs (Canis familiaris) have developed a close relationship with humans through the process of domestication. In human-dog interactions, eye contact is a key element of relationship initiation and maintenance. Previous studies have suggested that canine ability to produce human-directed communicative signals is influenced by domestication history, from wolves to dogs, as well as by recent breed selection for particular working purposes. To test the genetic basis for such abilities in purebred dogs, we examined gazing behavior towards humans using two types of behavioral experiments: the 'visual contact task' and the 'unsolvable task'. A total of 125 dogs participated in the study. Based on the genetic relatedness among breeds subjects were classified into five breed groups: Ancient, Herding, Hunting, Retriever-Mastiff and Working). We found that it took longer time for Ancient breeds to make an eye-contact with humans, and that they gazed at humans for shorter periods of time than any other breed group in the unsolvable situation. Our findings suggest that spontaneous gaze behavior towards humans is associated with genetic similarity to wolves rather than with recent selective pressure to create particular working breeds.
NASA Astrophysics Data System (ADS)
Kajiwara, Yusuke; Murata, Hiroaki; Kimura, Haruhiko; Abe, Koji
As a communication support tool for cases of amyotrophic lateral sclerosis (ALS), researches on eye gaze human-computer interfaces have been active. However, since voluntary and involuntary eye movements cannot be distinguished in the interfaces, their performance is still not sufficient for practical use. This paper presents a high performance human-computer interface system which unites high quality recognitions of horizontal directional eye movements and voluntary blinks. The experimental results have shown that the number of incorrect inputs is decreased by 35.1% in an existing system which equips recognitions of horizontal and vertical directional eye movements in addition to voluntary blinks and character inputs are speeded up by 17.4% from the existing system.
Human-machine interfaces based on EMG and EEG applied to robotic systems.
Ferreira, Andre; Celeste, Wanderley C; Cheein, Fernando A; Bastos-Filho, Teodiano F; Sarcinelli-Filho, Mario; Carelli, Ricardo
2008-03-26
Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, which need just a few hardware and software resources, so that they are, computationally and financially speaking, low cost solutions. Both interfaces were applied to robotic systems, and their performances are analyzed here. The EMG-based HMI was tested in a mobile robot, while the EEG-based HMI was tested in a mobile robot and a robotic manipulator as well. Experiments using the EMG-based HMI were carried out by eight individuals, who were asked to accomplish ten eye blinks with each eye, in order to test the eye blink detection algorithm. An average rightness rate of about 95% reached by individuals with the ability to blink both eyes allowed to conclude that the system could be used to command devices. Experiments with EEG consisted of inviting 25 people (some of them had suffered cases of meningitis and epilepsy) to test the system. All of them managed to deal with the HMI in only one training session. Most of them learnt how to use such HMI in less than 15 minutes. The minimum and maximum training times observed were 3 and 50 minutes, respectively. Such works are the initial parts of a system to help people with neuromotor diseases, including those with severe dysfunctions. The next steps are to convert a commercial wheelchair in an autonomous mobile vehicle; to implement the HMI onboard the autonomous wheelchair thus obtained to assist people with motor diseases, and to explore the potentiality of EEG signals, making the EEG-based HMI more robust and faster, aiming at using it to help individuals with severe motor dysfunctions.
Hirtl, Rene; Schmid, Gernot
2013-09-21
A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.
Determination of loss tangent of human tear film at 9.8 GHz
NASA Astrophysics Data System (ADS)
Bansal, Namita; Dhaliwal, A. S.; Mann, K. S.
2015-08-01
Basal (non-stimulated) tears that are produced by accessory lacrimal glands located in conjunctiva of human eye, form tear film which in turn keeps the eye moist and lubricate; nourishes the eye; protects the eye from dust, bacterial infection and shear forces generated during eye movements and blinking; and provides a refractive surface on the corneal epithelium. Film is known to contain water, mucin, lipids, lysozyme, glucose, urea, sodium etc. In present communication, loss tangent of human tear film has been determined at 9.8 GHz microwaves by employing cavity perturbation technique at a temperature of 37°C. The basal tears from a small population comprising six subjects were collected and average value of loss tangent is reported. Slater's technique was used to reduce the error caused in measuring the volume of sample. The determined values are useful to study the biological effects of microwaves on tear film as well as other parts of human eye such as eye lens and lens epithelial cells. To the best of author's knowledge, no such study is available in literature at any radio as well as microwave frequencies; therefore present determinations are first of its kind.
Visual optics: an engineering approach
NASA Astrophysics Data System (ADS)
Toadere, Florin
2010-11-01
The human eyes' visual system interprets the information from the visible light in order to build a representation of the world surrounding the body. It derives color by comparing the responses to light from the three types of photoreceptor cones in the eyes. These long medium and short cones are sensitive to blue, green and red portions of the visible spectrum. We simulate the color vision for the normal eyes. We see the effects of the dyes, filters, glasses and windows on color perception when the test image is illuminated with the D65 light sources. In addition to colors' perception, the human eyes can suffer from diseases and disorders. The eye can be seen as an optical instrument which has its own eye print. We present aspects of some nowadays methods and technologies which can capture and correct the human eyes' wavefront aberrations. We focus our attention to Siedel aberrations formula, Zenike polynomials, Shack-Hartmann Sensor, LASIK, interferograms fringes aberrations and Talbot effect.
HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye
NASA Astrophysics Data System (ADS)
Galetskii, S. O.; Cherezova, T. Yu
2009-02-01
An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.
A new mapping function in table-mounted eye tracker
NASA Astrophysics Data System (ADS)
Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng
2018-01-01
Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.
Hornof, Margit; Weyenberg, Wim; Ludwig, Annick; Bernkop-Schnürch, Andreas
2003-05-20
The aim of the study was to develop a mucoadhesive ocular insert for the controlled delivery of ophthalmic drugs and to evaluate its efficacy in vivo. The inserts tested were based either on unmodified or thiolated poly(acrylic acid). Water uptake and swelling behavior of the inserts as well as the drug release rates of the model drugs fluorescein and two diclofenac salts with different solubility properties were evaluated in vitro. Fluorescein was used as fluorescent tracer to study the drug release from the insert in humans. The mean fluorescein concentration in the cornea/tearfilm compartment as a function of time was determined after application of aqueous eye drops and inserts composed of unmodified and of thiolated poly(acrylic acid). The acceptability of the inserts by the volunteers was also evaluated. Inserts based on thiolated poly(acrylic acid) were not soluble and had good cohesive properties. A controlled release was achieved for the incorporated model drugs. The in vivo study showed that inserts based on thiolated poly(acrylic acid) provide a fluorescein concentration on the eye surface for more than 8 h, whereas the fluorescein concentration rapidly decreased after application of aqueous eye drops or inserts based on unmodified poly(acrylic acid). Moreover, these inserts were well accepted by the volunteers. The present study indicates that ocular inserts based on thiolated poly(acrylic acid) are promising new solid devices for ocular drug delivery.
Chimpanzees and Humans Mimic Pupil-Size of Conspecifics
Kret, Mariska E.; Tomonaga, Masaki; Matsuzawa, Tetsuro
2014-01-01
Group-living typically provides benefits to individual group members but also confers costs. To avoid incredulity and betrayal and allow trust and cooperation, individuals must understand the intentions and emotions of their group members. Humans attend to other's eyes and from gaze and pupil-size cues, infer information about the state of mind of the observed. In humans, pupil-size tends to mimic that of the observed. Here we tested whether pupil-mimicry exists in our closest relative, the chimpanzee (P. troglodytes). We conjectured that if pupil-mimicry has adaptive value, e.g. to promote swift communication of inner states and facilitate shared understanding and coordination, pupil-mimicry should emerge within but not across species. Pupillometry data was collected from human and chimpanzee subjects while they observed images of the eyes of both species with dilating/constricting pupils. Both species showed enhanced pupil-mimicry with members of their own species, with effects being strongest in humans and chimpanzee mothers. Pupil-mimicry may be deeply-rooted, but probably gained importance from the point in human evolution where the morphology of our eyes became more prominent. Humans' white sclera surrounding the iris, and the fine muscles around their eyes facilitate non-verbal communication via eye signals. PMID:25140998
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
Background In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. Aim To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Subjects & Methods Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (N=88), and brain and visual cortex (N=99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. Results A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes, (iii) different visual cortical areas, independently of overall brain volume. Conclusion In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices. PMID:23879766
Can human eyes prevent perceptual narrowing for monkey faces in human infants?
Damon, Fabrice; Bayet, Laurie; Quinn, Paul C; Hillairet de Boisferon, Anne; Méary, David; Dupierrix, Eve; Lee, Kang; Pascalis, Olivier
2015-07-01
Perceptual narrowing has been observed in human infants for monkey faces: 6-month-olds can discriminate between them, whereas older infants from 9 months of age display difficulty discriminating between them. The difficulty infants from 9 months have processing monkey faces has not been clearly identified. It could be due to the structural characteristics of monkey faces, particularly the key facial features that differ from human faces. The current study aimed to investigate whether the information conveyed by the eyes is of importance. We examined whether the presence of Caucasian human eyes in monkey faces allows recognition to be maintained in 6-month-olds and facilitates recognition in 9- and 12-month-olds. Our results revealed that the presence of human eyes in monkey faces maintains recognition for those faces at 6 months of age and partially facilitates recognition of those faces at 9 months of age, but not at 12 months of age. The findings are interpreted in the context of perceptual narrowing and suggest that the attenuation of processing of other-species faces is not reversed by the presence of human eyes. © 2015 Wiley Periodicals, Inc.
Dose conversion coefficients for photon exposure of the human eye lens.
Behrens, R; Dietze, G
2011-01-21
In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.
Dose conversion coefficients for photon exposure of the human eye lens
NASA Astrophysics Data System (ADS)
Behrens, R.; Dietze, G.
2011-01-01
In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.
The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation
Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt
2010-01-01
Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.
Verstraelen, Sandra; Van Rompay, An R
2018-06-01
The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Paediatric eye injuries in Finland - Helsinki eye trauma study.
Haavisto, Anna-Kaisa; Sahraravand, Ahmad; Holopainen, Juha M; Leivo, Tiina
2017-06-01
To determine the current population-based epidemiology, treatment, use of resources and outcomes of children's eye injuries in Finland. The study included all new patients, 16 years of age or under, with ocular or orbital traumas taken into care to the Helsinki University Eye Hospital (population base 1.5 million people) in 1 year. The follow-up period was 3 months. Two hundred and two children's eye injuries were treated. The eye injury incidence was 5.2-8.3 per 10 000 per year, including all minor and major eye traumas. Eye injury most likely occurred at the junior high school age (13-16 years). Thirty-three percentage of accidents took place at home and 24% at school or in day care. The most common causes were sports equipment (15%), contact with human body (12%) and superficial foreign bodies (11%). Excluding minor injuries, contusion was the most common diagnosis (n = 60, 30%). Eighty-seven percentage of contusion patients were estimated to need lifelong follow-up due to elevated glaucoma risk. Nine percentage of all patients had a permanent disability. Guns, fireworks, tools and pellet guns were relatively the most dangerous objects. Pellet guns caused 6% of eye injuries, 36% of them causing permanent impairment. The number of outpatient visits was altogether 443, inpatient days were 49, and 60 children had major surgeries. Use of protective eyewear would have prevented or diminished eye traumas caused by pellet gun, floorball, most of the firework and in many superficial foreign body. The use of pellet guns and protective eyewear should be more supervised. Fireworks and tools are not suitable toys for children. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
The µ-opioid system promotes visual attention to faces and eyes.
Chelnokova, Olga; Laeng, Bruno; Løseth, Guro; Eikemo, Marie; Willoch, Frode; Leknes, Siri
2016-12-01
Paying attention to others' faces and eyes is a cornerstone of human social behavior. The µ-opioid receptor (MOR) system, central to social reward-processing in rodents and primates, has been proposed to mediate the capacity for affiliative reward in humans. We assessed the role of the human MOR system in visual exploration of faces and eyes of conspecifics. Thirty healthy males received a novel, bidirectional battery of psychopharmacological treatment (an MOR agonist, a non-selective opioid antagonist, or placebo, on three separate days). Eye-movements were recorded while participants viewed facial photographs. We predicted that the MOR system would promote visual exploration of faces, and hypothesized that MOR agonism would increase, whereas antagonism decrease overt attention to the information-rich eye region. The expected linear effect of MOR manipulation on visual attention to the stimuli was observed, such that MOR agonism increased while antagonism decreased visual exploration of faces and overt attention to the eyes. The observed effects suggest that the human MOR system promotes overt visual attention to socially significant cues, in line with theories linking reward value to gaze control and target selection. Enhanced attention to others' faces and eyes represents a putative behavioral mechanism through which the human MOR system promotes social interest. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Eye Contact Is Crucial for Referential Communication in Pet Dogs.
Savalli, Carine; Resende, Briseida; Gaunet, Florence
2016-01-01
Dogs discriminate human direction of attention cues, such as body, gaze, head and eye orientation, in several circumstances. Eye contact particularly seems to provide information on human readiness to communicate; when there is such an ostensive cue, dogs tend to follow human communicative gestures more often. However, little is known about how such cues influence the production of communicative signals (e.g. gaze alternation and sustained gaze) in dogs. In the current study, in order to get an unreachable food, dogs needed to communicate with their owners in several conditions that differ according to the direction of owners' visual cues, namely gaze, head, eyes, and availability to make eye contact. Results provided evidence that pet dogs did not rely on details of owners' direction of visual attention. Instead, they relied on the whole combination of visual cues and especially on the owners' availability to make eye contact. Dogs increased visual communicative behaviors when they established eye contact with their owners, a different strategy compared to apes and baboons, that intensify vocalizations and gestures when human is not visually attending. The difference in strategy is possibly due to distinct status: domesticated vs wild. Results are discussed taking into account the ecological relevance of the task since pet dogs live in human environment and face similar situations on a daily basis during their lives.
Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min
2015-01-01
The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556
Contrast-based sensorless adaptive optics for retinal imaging.
Zhou, Xiaolin; Bedggood, Phillip; Bui, Bang; Nguyen, Christine T O; He, Zheng; Metha, Andrew
2015-09-01
Conventional adaptive optics ophthalmoscopes use wavefront sensing methods to characterize ocular aberrations for real-time correction. However, there are important situations in which the wavefront sensing step is susceptible to difficulties that affect the accuracy of the correction. To circumvent these, wavefront sensorless adaptive optics (or non-wavefront sensing AO; NS-AO) imaging has recently been developed and has been applied to point-scanning based retinal imaging modalities. In this study we show, for the first time, contrast-based NS-AO ophthalmoscopy for full-frame in vivo imaging of human and animal eyes. We suggest a robust image quality metric that could be used for any imaging modality, and test its performance against other metrics using (physical) model eyes.
Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.
Chang, David F; Mamalis, Nick; Werner, Liliana
2016-02-01
To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory infiltrates. Precision pulse capsulotomy is a new method to automate consistent creation of a perfectly circular anterior capsulotomy with a disposable handheld instrument that can be used in the normal phacoemulsification surgical sequence. Compared with CCC in fellow rabbit eyes, PPC was equally safe and showed no greater zonular stress compared with CCC in human cadaver eyes. Human cadaver eye SEM showed a much smoother capsulotomy edge compared to those produced by femtosecond laser. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Optoelectronic Apparatus Measures Glucose Noninvasively
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Rovati, Luigi L.
2003-01-01
An optoelectronic apparatus has been invented as a noninvasive means of measuring the concentration of glucose in the human body. The apparatus performs polarimetric and interferometric measurements of the human eye to acquire data from which the concentration of glucose in the aqueous humor can be computed. Because of the importance of the concentration of glucose in human health, there could be a large potential market for instruments based on this apparatus.
Automatic red eye correction and its quality metric
NASA Astrophysics Data System (ADS)
Safonov, Ilia V.; Rychagov, Michael N.; Kang, KiMin; Kim, Sang Ho
2008-01-01
The red eye artifacts are troublesome defect of amateur photos. Correction of red eyes during printing without user intervention and making photos more pleasant for an observer are important tasks. The novel efficient technique of automatic correction of red eyes aimed for photo printers is proposed. This algorithm is independent from face orientation and capable to detect paired red eyes as well as single red eyes. The approach is based on application of 3D tables with typicalness levels for red eyes and human skin tones and directional edge detection filters for processing of redness image. Machine learning is applied for feature selection. For classification of red eye regions a cascade of classifiers including Gentle AdaBoost committee from Classification and Regression Trees (CART) is applied. Retouching stage includes desaturation, darkening and blending with initial image. Several versions of approach implementation using trade-off between detection and correction quality, processing time, memory volume are possible. The numeric quality criterion of automatic red eye correction is proposed. This quality metric is constructed by applying Analytic Hierarchy Process (AHP) for consumer opinions about correction outcomes. Proposed numeric metric helped to choose algorithm parameters via optimization procedure. Experimental results demonstrate high accuracy and efficiency of the proposed algorithm in comparison with existing solutions.
An optomechanical model eye for ophthalmological refractive studies.
Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa
2013-02-01
To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.
``Magical'' fluid pathways: inspired airflow corridors for optimal drug delivery to human sinuses
NASA Astrophysics Data System (ADS)
Basu, Saikat; Farzal, Zainab; Kimbell, Julia S.
2017-11-01
Topical delivery methods like nasal sprays are an important therapeutic component for sinusitis (inflammation and clogging of the paranasal sinuses). The sinuses are air-filled sacs, identified as: maxillaries (under the eyes and deep to cheeks bilaterally; largest in volume), frontals (above and medial to the eyes, behind forehead area), ethmoids (between the eyes, inferior to the frontal sinuses), and sphenoids (superior and posterior to ethmoids). We develop anatomic CT-based 3D reconstructions of the human nasal cavity for multiple subjects. Through CFD simulations on Fluent for measured breathing rates, we track inspiratory airflow in all the models and the corresponding sprayed drug transport (for a commercially available sprayer, with experimentally tested particle size distributions). The protocol is implemented for a wide array of spray release points. We make the striking observation that the same release points in each subject provide better particle deposition in all the sinuses, despite the sinuses being located at different portions of the nasal cavity. This leads to the conjecture that the complicated anatomy-based flow physics artifacts in the nasal canal generate certain ``magical'' streamlines, providing passage for improved drug transport to all sinus targets. Supported by NIH Grant R01 HL122154.
See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction.
Xu, Tian Linger; Zhang, Hui; Yu, Chen
2016-05-01
We focus on a fundamental looking behavior in human-robot interactions - gazing at each other's face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user's face as a response to the human's gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot's gaze toward the human partner's face in real time and then analyzed the human's gaze behavior as a response to the robot's gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot's face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained.
Introduction to the development of intraocular lens
NASA Astrophysics Data System (ADS)
Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2013-08-01
In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.
Defining the Human Macula Transcriptome and Candidate Retinal Disease Genes UsingEyeSAGE
Rickman, Catherine Bowes; Ebright, Jessica N.; Zavodni, Zachary J.; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P.; Wistow, Graeme; Boon, Kathy; Hauser, Michael A.
2009-01-01
Purpose To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Methods Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Results Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. Conclusions The EyeSAGE database, combining three different gene-profiling platforms including the authors’ multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions. PMID:16723438
Defining the human macula transcriptome and candidate retinal disease genes using EyeSAGE.
Bowes Rickman, Catherine; Ebright, Jessica N; Zavodni, Zachary J; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P; Wistow, Graeme; Boon, Kathy; Hauser, Michael A
2006-06-01
To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. The EyeSAGE database, combining three different gene-profiling platforms including the authors' multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions.
Estimating Human Trabecular Meshwork Stiffness by Numerical Modeling and Advanced OCT Imaging.
Wang, Ke; Johnstone, Murray A; Xin, Chen; Song, Shaozhen; Padilla, Steven; Vranka, Janice A; Acott, Ted S; Zhou, Kai; Schwaner, Stephen A; Wang, Ruikang K; Sulchek, Todd; Ethier, C Ross
2017-09-01
The purpose of this study was to estimate human trabecular meshwork (hTM) stiffness, thought to be elevated in glaucoma, using a novel indirect approach, and to compare results with direct en face atomic force microscopy (AFM) measurements. Postmortem human eyes were perfused to measure outflow facility and identify high- and low-flow regions (HF, LF) by tracer. Optical coherence tomography (OCT) images were obtained as Schlemm's canal luminal pressure was directly manipulated. TM stiffness was deduced by an inverse finite element modeling (FEM) approach. A series of AFM forcemaps was acquired along a line traversing the anterior angle on a radially cut flat-mount corneoscleral wedge with TM facing upward. The elastic modulus of normal hTM estimated by inverse FEM was 70 ± 20 kPa (mean ± SD), whereas glaucomatous hTM was slightly stiffer (98 ± 19 kPa). This trend was consistent with TM stiffnesses measured by AFM: normal hTM stiffness = 1.37 ± 0.56 kPa, which was lower than glaucomatous hTM stiffness (2.75 ± 1.19 kPa). None of these differences were statistically significant. TM in HF wedges was softer than that in LF wedges for both normal and glaucomatous eyes based on the inverse FEM approach but not by AFM. Outflow facility was significantly correlated with TM stiffness estimated by FEM in six human eyes (P = 0.018). TM stiffness is higher, but only modestly so, in glaucomatous patients. Outflow facility in both normal and glaucomatous human eyes appears to associate with TM stiffness. This evidence motivates further studies to investigate factors underlying TM biomechanical property regulation.
Walsh, Susan; Lindenbergh, Alexander; Zuniga, Sofia B; Sijen, Titia; de Knijff, Peter; Kayser, Manfred; Ballantyne, Kaye N
2011-11-01
The IrisPlex system consists of a highly sensitive multiplex genotyping assay together with a statistical prediction model, providing users with the ability to predict blue and brown human eye colour from DNA samples with over 90% precision. This 'DNA intelligence' system is expected to aid police investigations by providing phenotypic information on unknown individuals when conventional DNA profiling is not informative. Falling within the new area of forensic DNA phenotyping, this paper describes the developmental validation of the IrisPlex assay following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for the application of DNA-based eye colour prediction to forensic casework. The IrisPlex assay produces complete SNP genotypes with only 31pg of DNA, approximately six human diploid cell equivalents, and is therefore more sensitive than commercial STR kits currently used in forensics. Species testing revealed human and primate specificity for a complete SNP profile. The assay is capable of producing accurate results from simulated casework samples such as blood, semen, saliva, hair, and trace DNA samples, including extremely low quantity samples. Due to its design, it can also produce full profiles with highly degraded samples often found in forensic casework. Concordance testing between three independent laboratories displayed reproducible results of consistent levels on varying types of simulated casework samples. With such high levels of sensitivity, specificity, consistency and reliability, this genotyping assay, as a core part of the IrisPlex system, operates in accordance with SWGDAM guidelines. Furthermore, as we demonstrated previously, the IrisPlex eye colour prediction system provides reliable results without the need for knowledge on the bio-geographic ancestry of the sample donor. Hence, the IrisPlex system, with its model-based prediction probability estimation of blue and brown human eye colour, represents a useful tool for immediate application in accredited forensic laboratories, to be used for forensic intelligence in tracing unknown individuals from crime scene samples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M
2017-02-01
Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.
Improved high-resolution ultrasonic imaging of the eye.
Silverman, Ronald H; Ketterling, Jeffrey A; Mamou, Jonathan; Coleman, D Jackson
2008-01-01
Currently, virtually all clinical diagnostic ultrasound systems used in ophthalmology are based on fixed-focus, single-element transducers. High-frequency (> or = 20-MHz) transducers introduced to ophthalmology during the last decade have led to improved resolution and diagnostic capabilities for assessment of the anterior segment and the retina. However, single-element transducers are restricted to a small depth of field, limiting their capacity to image the eye as a whole. We fabricated a 20-MHz annular array probe prototype consisting of 5 concentric transducer elements and scanned an ex vivo human eye. Synthetically focused images of the bank eye showed improved depth of field and sensitivity, allowing simultaneous display of the anterior and posterior segments and the full lens contour. This capability may be useful in assessment of vitreoretinal pathologies and investigation of the accommodative mechanism.
Molecular Diagnosis of Human Taenia martis Eye Infection
Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis
2016-01-01
Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. PMID:26928837
Expression of classical components of the renin-angiotensin system in the human eye.
White, Andrew J R; Cheruvu, Sarat C; Sarris, Maria; Liyanage, Surabhi S; Lumbers, Eugenie; Chui, Jeanie; Wakefield, Denis; McCluskey, Peter J
2015-03-01
The purpose of this study was to determine the relative expression of clinically-relevant components of the renin-angiotensin system (RAS) in the adult human eye. We obtained 14 post-mortem enucleated human eyes from patients whom had no history of inflammatory ocular disease nor pre-mortem ocular infection. We determined the gene expression for prorenin, renin, prorenin receptor, angiotensin-converting enzyme, angiotensinogen and angiotensin II Type 1 receptor, on tissue sections and in cultured human primary retinal pigment epithelial and iris pigment epithelial (RPE/IPE) cell lines, using both qualitative and quantitative reverse transcription polymerase chain reaction (RT-PCR). Protein expression was studied using indirect immunofluorescence (IF). Almost all components of the classical RAS were found at high levels, at both the transcript and protein level, in the eyes' uvea and retina; and at lower levels in the cornea, conjunctiva and sclera. There was a much lower level of expression in the reference cultured RPE/IPE cells lines. This study describes the distribution of RAS in the normal adult human eye and demonstrates the existence of an independent ocular RAS, with uveal and retinal tissues showing the highest expression of RAS components. These preliminary findings provide scope for examination of additional components of this system in the human eye, as well as possible differential expression under pathological conditions. © The Author(s) 2014.
Human-technology interaction for standoff IED detection
NASA Astrophysics Data System (ADS)
Zhang, Evan; Zou, Yiyang; Zachrich, Liping; Fulton, Jack
2011-03-01
IEDs kill our soldiers and innocent people every day. Lessons learned from Iraq and Afghanistan clearly indicated that IEDs cannot be detected/defeated by technology alone; human-technology interaction must be engaged. In most cases, eye is the best detector, brain is the best computer, and technologies are tools, they must be used by human being properly then can achieve full functionality. In this paper, a UV Raman/fluorescence, CCD and LWIR 3 sensor fusion system for standoff IED detection and a handheld fusion system for close range IED detection are developed and demonstrated. We must train solders using their eyes or CCD/LWIR cameras to do wide area search while on the move to find small suspected area first then use the spectrometer because the laser spot is too small, to scan a one-mile long and 2-meter wide road needs 185 days although our fusion system can detect the IED in 30m with 1s interrogating time. Even if the small suspected area (e.g., 0.5mx0.5m) is found, human eyes still cannot detect the IED, soldiers must use or interact with the technology - laser based spectrometer to scan the area then they are able to detect and identify the IED in 10 minutes not 185 days. Therefore, the human-technology interaction approach will be the best solution for IED detection.
NASA Astrophysics Data System (ADS)
Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan
2013-04-01
Objective. Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. Approach. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Main results. Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min-1. A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. Significance. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our ‘eyes-closed’ SSVEP-based BCI system can be potentially used for communication of disabled individuals with impaired oculomotor function.
Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan
2013-04-01
Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min(-1). A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our 'eyes-closed' SSVEP-based BCI system can be potentially used for communication of disabled individuals with impaired oculomotor function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovesdi, C.; Spielman, Z.; LeBlanc, K.
An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collectmore » and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.« less
Del Amo, Eva M; Urtti, Arto
2015-08-01
Intravitreal administration is the method of choice in drug delivery to the retina and/or choroid. Rabbit is the most commonly used animal species in intravitreal pharmacokinetics, but it has been criticized as being a poor model of human eye. The critique is based on some anatomical differences, properties of the vitreous humor, and observed differences in drug concentrations in the anterior chamber after intravitreal injections. We have systematically analyzed all published information on intravitreal pharmacokinetics in the rabbit and human eye. The analysis revealed major problems in the design of the pharmacokinetic studies. In this review we provide advice for study design. Overall, the pharmacokinetic parameters (clearance, volume of distribution, half-life) in the human and rabbit eye have good correlation and comparable absolute values. Therefore, reliable rabbit-to-man translation of intravitreal pharmacokinetics should be feasible. The relevant anatomical and physiological parameters in rabbit and man show only small differences. Furthermore, the claimed discrepancy between drug concentrations in the human and rabbit aqueous humor is not supported by the data analysis. Based on the available and properly conducted pharmacokinetic studies, the differences in the vitreous structure in rabbits and human patients do not lead to significant pharmacokinetic differences. This review is the first step towards inter-species translation of intravitreal pharmacokinetics. More information is still needed to dissect the roles of drug delivery systems, disease states, age and ocular manipulation on the intravitreal pharmacokinetics in rabbit and man. Anyway, the published data and the derived pharmacokinetic parameters indicate that the rabbit is a useful animal model in intravitreal pharmacokinetics. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Objective evaluation of the visual acuity in human eyes
NASA Astrophysics Data System (ADS)
Rosales, M. A.; López-Olazagasti, E.; Ramírez-Zavaleta, G.; Varillas, G.; Tepichín, E.
2009-08-01
Traditionally, the quality of the human vision is evaluated by a subjective test in which the examiner asks the patient to read a series of characters of different sizes, located at a certain distance of the patient. Typically, we need to ensure a subtended angle of vision of 5 minutes, which implies an object of 8.8 mm high located at 6 meters (normal or 20/20 visual acuity). These characters constitute what is known as the Snellen chart, universally used to evaluate the spatial resolution of the human eyes. The mentioned process of identification of characters is carried out by means of the eye - brain system, giving an evaluation of the subjective visual performance. In this work we consider the eye as an isolated image-forming system, and show that it is possible to isolate the function of the eye from that of the brain in this process. By knowing the impulse response of the eye´s system we can obtain, in advance, the image of the Snellen chart simultaneously. From this information, we obtain the objective performance of the eye as the optical system under test. This type of results might help to detect anomalous situations of the human vision, like the so called "cerebral myopia".
Glucose Transporters are Abundant in Cells with "Occluding" Junctions at the Blood-Eye Barriers
NASA Astrophysics Data System (ADS)
Harik, Sami I.; Kalaria, Rajesh N.; Whitney, Paul M.; Andersson, Lars; Lundahl, Per; Ledbetter, Steven R.; Perry, George
1990-06-01
We studied the distribution of the "erythroid/brain" glucose transporter protein in the human and rat eye by immunocytochemistry with monoclonal and polyclonal antibodies to the C terminus of the human erythrocyte glucose transporter. We found intense immunocytochemical staining in the endothelium of microvessels of the retina, optic nerve, and iris but not in microvessels of the choroid, ciliary body, sclera, and other retro-orbital tissues. In addition, we found marked immunocytochemical staining of retinal pigment epithelium, ciliary body epithelium, and posterior epithelium of the iris. The common feature of all those endothelial and epithelial cells that stained intensely for the glucose transporter is the presence of "occluding" intercellular junctions, which constitute the anatomical bases of the blood-eye barriers. We propose that a high density of the glucose transporter is a biochemical concomitant of epithelial and endothelial cells with barrier characteristics, at least in tissues that have a high metabolic requirement for glucose.
ERIC Educational Resources Information Center
Edwards, S. J.
1975-01-01
Provides information on how humans see color including sensitivity of the eye, spatial effects, and temporal effects, and relative to the characteristics of the human eye explains how color is measured. (GS)
Cyclodextrins in eye drop formulations: enhanced topical delivery of corticosteroids to the eye.
Loftsson, Thorsteinn; Stefánsson, Einar
2002-04-01
Cyclodextrins are cylindrical oligosaccharides with a lipophilic central cavity and hydrophilic outer surface. They can form water-soluble complexes with lipophilic drugs, which 'hide' in the cavity. Cyclodextrins can be used to form aqueous eye drop solutions with lipophilic drugs, such as steroids and some carbonic anhydrase inhibitors. The cyclodextrins increase the water solubility of the drug, enhance drug absorption into the eye, improve aqueous stability and reduce local irritation. Cyclodextrins are useful excipients in eye drop formulations of various drugs, including steroids of any kind, carbonic anhydrase inhibitors, pilocarpine, cyclosporins, etc. Their use in ophthalmology has already begun and is likely to expand the selection of drugs available as eye drops. In this paper we review the properties of cyclodextrins and their application in eye drop formulations, of which their use in the formulation of dexamethasone eye drops is an example. Cyclodextrins have been used to formulate eye drops containing corticosteroids, such as dexamethasone, with levels of concentration and ocular absorption which, according to human and animal studies, are many times those seen with presently available formulations. Cyclodextrin-based dexamethasone eye drops are well tolerated in the eye and seem to provide a higher degree of bioavailability and clinical efficiency than the steroid eye drop formulations presently available. Such formulations offer the possibility of once per day application of corticosteroid eye drops after eye surgery, and more intensive topical steroid treatment in severe inflammation. While cyclodextrins have been known for more than a century, their use in ophthalmology is just starting. Cyclodextrins are useful excipients in eye drop formulations for a variety of lipophilic drugs. They will facilitate eye drop formulations for drugs that otherwise might not be available for topical use, while improving absorption and stability and decreasing local irritation.
Izak, Andrea M; Werner, Liliana; Pandey, Suresh K; Apple, David J
2004-07-01
To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.
A Novel Wearable Forehead EOG Measurement System for Human Computer Interfaces
Heo, Jeong; Yoon, Heenam; Park, Kwang Suk
2017-01-01
Amyotrophic lateral sclerosis (ALS) patients whose voluntary muscles are paralyzed commonly communicate with the outside world using eye movement. There have been many efforts to support this method of communication by tracking or detecting eye movement. An electrooculogram (EOG), an electro-physiological signal, is generated by eye movements and can be measured with electrodes placed around the eye. In this study, we proposed a new practical electrode position on the forehead to measure EOG signals, and we developed a wearable forehead EOG measurement system for use in Human Computer/Machine interfaces (HCIs/HMIs). Four electrodes, including the ground electrode, were placed on the forehead. The two channels were arranged vertically and horizontally, sharing a positive electrode. Additionally, a real-time eye movement classification algorithm was developed based on the characteristics of the forehead EOG. Three applications were employed to evaluate the proposed system: a virtual keyboard using a modified Bremen BCI speller and an automatic sequential row-column scanner, and a drivable power wheelchair. The mean typing speeds of the modified Bremen brain–computer interface (BCI) speller and automatic row-column scanner were 10.81 and 7.74 letters per minute, and the mean classification accuracies were 91.25% and 95.12%, respectively. In the power wheelchair demonstration, the user drove the wheelchair through an 8-shape course without collision with obstacles. PMID:28644398
A Novel Wearable Forehead EOG Measurement System for Human Computer Interfaces.
Heo, Jeong; Yoon, Heenam; Park, Kwang Suk
2017-06-23
Amyotrophic lateral sclerosis (ALS) patients whose voluntary muscles are paralyzed commonly communicate with the outside world using eye movement. There have been many efforts to support this method of communication by tracking or detecting eye movement. An electrooculogram (EOG), an electro-physiological signal, is generated by eye movements and can be measured with electrodes placed around the eye. In this study, we proposed a new practical electrode position on the forehead to measure EOG signals, and we developed a wearable forehead EOG measurement system for use in Human Computer/Machine interfaces (HCIs/HMIs). Four electrodes, including the ground electrode, were placed on the forehead. The two channels were arranged vertically and horizontally, sharing a positive electrode. Additionally, a real-time eye movement classification algorithm was developed based on the characteristics of the forehead EOG. Three applications were employed to evaluate the proposed system: a virtual keyboard using a modified Bremen BCI speller and an automatic sequential row-column scanner, and a drivable power wheelchair. The mean typing speeds of the modified Bremen brain-computer interface (BCI) speller and automatic row-column scanner were 10.81 and 7.74 letters per minute, and the mean classification accuracies were 91.25% and 95.12%, respectively. In the power wheelchair demonstration, the user drove the wheelchair through an 8-shape course without collision with obstacles.
An Insect Eye Inspired Miniaturized Multi-Camera System for Endoscopic Imaging.
Cogal, Omer; Leblebici, Yusuf
2017-02-01
In this work, we present a miniaturized high definition vision system inspired by insect eyes, with a distributed illumination method, which can work in dark environments for proximity imaging applications such as endoscopy. Our approach is based on modeling biological systems with off-the-shelf miniaturized cameras combined with digital circuit design for real time image processing. We built a 5 mm radius hemispherical compound eye, imaging a 180 ° ×180 ° degrees field of view while providing more than 1.1 megapixels (emulated ommatidias) as real-time video with an inter-ommatidial angle ∆ϕ = 0.5 ° at 18 mm radial distance. We made an FPGA implementation of the image processing system which is capable of generating 25 fps video with 1080 × 1080 pixel resolution at a 120 MHz processing clock frequency. When compared to similar size insect eye mimicking systems in literature, the system proposed in this paper features 1000 × resolution increase. To the best of our knowledge, this is the first time that a compound eye with built-in illumination idea is reported. We are offering our miniaturized imaging system for endoscopic applications like colonoscopy or laparoscopic surgery where there is a need for large field of view high definition imagery. For that purpose we tested our system inside a human colon model. We also present the resulting images and videos from the human colon model in this paper.
Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González, Héctor; Alvarez, Lydia; Coca-Prados, Miguel; Sanz-Medel, Alfredo
2013-04-01
Laser ablation coupled to inductively coupled plasma mass spectrometry has been developed for the elemental imaging of Mg, Fe and Cu distribution in histological tissue sections of fixed eyes, embedded in paraffin, from human donors (cadavers). This work presents the development of a novel internal standard correction methodology based on the deposition of a homogeneous thin gold film on the tissue surface and the use of the (197)Au(+) signal as internal standard. Sample preparation (tissue section thickness) and laser conditions were carefully optimized, and internal normalisation using (197)Au(+) was compared with (13)C(+) correction for imaging applications. (24)Mg(+), (56)Fe(+) and (63)Cu(+) distributions were investigated in histological sections of the anterior segment of the eye (including the iris, ciliary body, cornea and trabecular meshwork) and were shown to be heterogeneously distributed along those tissue structures. Reproducibility was assessed by imaging different human eye sections from the same donor and from ten different eyes from adult normal donors, which showed that similar spatial maps were obtained and therefore demonstrate the analytical potential of using (197)Au(+) as internal standard. The proposed analytical approach could offer a robust tool with great practical interest for clinical studies, e.g. to investigate trace element distribution of metals and their alterations in ocular diseases.
Lee, Miri; Nam, Ki Taek; Kim, Jungah; Lim, Song E; Yeon, Sang Hyeon; Lee, Buhyun; Lee, Joo Young; Lim, Kyung-Min
2017-10-01
Coal-tar dyes in cosmetics may elicit adverse effects in the skin and eyes. Countries, like the US, have banned the use of coal-tar dyes in cosmetics for the eye area due to the potential for ocular irritation. We evaluated the eye irritation potential of 15 coal-tar dyes permitted as cosmetic ingredients in reconstructed human cornea-like epithelium (RhCEs [EpiOcular™ and MCTT HCE™]) tests and the short time exposure (STE) test. Eosin YS, phloxine B, tetrachlorotetrabromofluorescein, and tetrabromofluorescein were identified as irritants in RhCEs; dibromofluorescein and uranine yielded discrepant results. STE enabled further classification in accordance with the UN Globally Harmonized System of Classification and Labelling of Chemicals, as follows: eosin YS as Cat 2; phloxine B, Cat 1; and tetrachlorotetrabromofluorescein and tetrabromofluorescein, Cat 1/2. STE indicated dibromofluorescein (irritant in EpiOcular™) and uranine (irritant in MCTT HCE™) as No Cat, resulting in the classification of "No prediction can be made." based on bottom-up approach with each model. These results demonstrated that in vitro eye irritation tests can be utilized to evaluate the potential ocular irritancy of cosmetic ingredients and provide significant evidence with which to determine whether precautions should be given for the use of coal-tar dyes in cosmetics or other substances applied to the eye area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Molecular Diagnosis of Human Taenia martis Eye Infection.
Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis
2016-05-04
Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. © The American Society of Tropical Medicine and Hygiene.
Ethical Issues in Transnational Eye Banking.
Martin, Dominique E; Kelly, Richard; Jones, Gary L A; Machin, Heather; Pollock, Graeme A
2017-02-01
To review ethical issues that may arise in the setting of transnational eye banking activities, such as when exporting or importing corneal tissue for transplantation. A principle-based normative analysis of potential common dilemmas in transnational eye banking activities was performed. Transnational activities in eye banking, like those in other fields involving procurement and use of medical products of human origin, may present a number of ethical issues for policy makers and professionals. Key ethical concerns include the potential impact of export or import activities on self-sufficiency of corneal tissue supply within exporting and importing countries; potential disclosure requirements when obtaining consent or authorization for ocular tissue donation when donations may be exported; and difficulties inherent in assuring equity in the allocation of tissues available for export and in establishing and respecting standards of safety and quality across different jurisdictions. Further analysis of specific ethical issues in eye banking is necessary to inform development of guidelines and other governance tools that will assist policy makers and professionals to support ethical practice.
Banerjee, Jayeeta; Majumdar, Dhurjati; Majumdar, Deepti; Pal, Madhu Sudan
2010-06-01
We are experiencing a shifting of media: from the printed paper to the computer screen. This transition is modifying the process of how we read and understand a text. It is very difficult to conclude on suitability of font characters based upon subjective evaluation method only. Present study evaluates the effect of font type on human cognitive workload during perception of individual alphabets on a computer screen. Twenty six young subjects volunteered for this study. Here, subjects have been shown individual characters of different font types and their eye movements have been recorded. A binocular eye movement recorder was used for eye movement recording. The results showed that different eye movement parameters such as pupil diameter, number of fixations, fixation duration were less for font type Verdana. The present study recommends the use of font type Verdana for presentation of individual alphabets on various electronic displays in order to reduce cognitive workload.
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects.
Kang, Ziho; Mandal, Saptarshi; Crutchfield, Jerry; Millan, Angel; McClung, Sarah N
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance.
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects
Mandal, Saptarshi
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance. PMID:27725830
Signal-dependent noise determines motor planning
NASA Astrophysics Data System (ADS)
Harris, Christopher M.; Wolpert, Daniel M.
1998-08-01
When we make saccadic eye movements or goal-directed arm movements, there is an infinite number of possible trajectories that the eye or arm could take to reach the target,. However, humans show highly stereotyped trajectories in which velocity profiles of both the eye and hand are smooth and symmetric for brief movements,. Here we present a unifying theory of eye and arm movements based on the single physiological assumption that the neural control signals are corrupted by noise whose variance increases with the size of the control signal. We propose that in the presence of such signal-dependent noise, the shape of a trajectory is selected to minimize the variance of the final eye or arm position. This minimum-variance theory accurately predicts the trajectories of both saccades and arm movements and the speed-accuracy trade-off described by Fitt's law. These profiles are robust to changes in the dynamics of the eye or arm, as found empirically,. Moreover, the relation between path curvature and hand velocity during drawing movements reproduces the empirical `two-thirds power law',. This theory provides a simple and powerful unifying perspective for both eye and arm movement control.
Questions Students Ask: The Red-Eye Effect.
ERIC Educational Resources Information Center
Physics Teacher, 1985
1985-01-01
Addresses the question of why a dog's eyes appear red and glow when a flash photograph is taken. Conditions for the red-eye effect, light paths involved, structure of the eye, and typical cameras and lenses are discussed. Also notes differences between the eyes of nocturnal animals and humans. (JN)
Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Hong-Jun; Alamudun, Folami T.; Hudson, Kathy
Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed thatmore » the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.« less
Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists
Yoon, Hong-Jun; Alamudun, Folami T.; Hudson, Kathy; ...
2018-01-24
Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed thatmore » the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.« less
Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.
2016-01-01
Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614
Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min
2015-09-01
Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.
76 FR 33286 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-08
... locations: Federal Housing Finance Agency, Office of Human Resources Management, 1700 G Street, NW... Human Resources Management, 1700 G Street, NW., Washington, DC 20552; 1625 Eye Street, NW., Washington...: Office of Human Resources Management, Federal Housing Finance Agency, 1625 Eye Street, NW., Washington...
Ocular attention-sensing interface system
NASA Technical Reports Server (NTRS)
Zaklad, Allen; Glenn, Floyd A., III; Iavecchia, Helene P.; Stokes, James M.
1986-01-01
The purpose of the research was to develop an innovative human-computer interface based on eye movement and voice control. By eliminating a manual interface (keyboard, joystick, etc.), OASIS provides a control mechanism that is natural, efficient, accurate, and low in workload.
Noninvasive detection of macular pigments in the human eye.
Gellermann, Werner; Bernstein, Paul S
2004-01-01
There is currently strong interest in developing noninvasive technologies for the detection of macular carotenoid pigments in the human eye. These pigments, consisting of lutein and zeaxanthin, are taken up from the diet and are thought to play an important role in the prevention of age-related macular degeneration, the leading cause of blindness in the elderly in the Western world. It may be possible to prevent or delay the onset of this debilitating disease with suitable dietary intervention strategies. We review the most commonly used detection techniques based on heterochromatic flicker photometry, fundus reflectometry, and autofluorescense techniques and put them in perspective with recently developed more molecule-specific Raman detection methods. (c) 2004 Society of Photo-Optical Instrumentation Engineers.
Holocamera for 3-D micrography of the alert human eye
NASA Astrophysics Data System (ADS)
Tokuda, A. R.; Auth, D. C.; Bruckner, A. P.
1980-07-01
A holocamera that safely records holograms of the full depth of the alert human eye with a spatial resolution of about 20 microns is described. A single-mode argon-ion laser generating 2 W at 5145 A serves as the illuminating source. Holographic exposure times of 0.3 msec are achieved by means of a fail-safe electromechanical shutter system. Integrated retinal irradiance levels are well under the American National Standards Institute safety standards. Reconstructed real images are projected directly onto the vidicon faceplate of a closed-circuit TV system, enabling convenient scanning in the x-y-z dimensions of the reconstructed eyeball. Serially reconstructed holograms of cataractous rabbit eyes and normal human eyes are presented.
Study of Light Scattering in the Human Eye
NASA Astrophysics Data System (ADS)
Perez, I. Kelly; Bruce, N. C.; Valdos, L. R. Berriel
2008-04-01
In this paper we present a numerical model of the human eye to be used in studies of the scattering of light in different components of the eye's optical system. Different parts of the eye are susceptible to produce scattering for different reasons; age, illness or injury. For example, cataracts can appear in the human lens or injuries or fungi can appear on the cornea. The aim of the study is to relate the backscattered light, which is what doctors measure or detect, to the forward scattered light, which is what affects the patient's vision. We present the model to be used, the raytrace procedure and some preliminary results for the image on the retina without scattering.
Ohnuma, Kazuhiko; Kayanuma, Hiroyuki; Lawu, Tjundewo; Negishi, Kazuno; Yamaguchi, Takefumi; Noda, Toru
2011-01-01
Correcting spherical and chromatic aberrations in vitro in human eyes provides substantial visual acuity and contrast sensitivity improvements. We found the same improvement in the retinal images using a model eye with/without correction of longitudinal chromatic aberrations (LCAs) and spherical aberrations (SAs). The model eye included an intraocular lens (IOL) and artificial cornea with human ocular LCAs and average human SAs. The optotypes were illuminated using a D65 light source, and the images were obtained using two-dimensional luminance colorimeter. The contrast improvement from the SA correction was higher than the LCA correction, indicating the benefit of an aspheric achromatic IOL. PMID:21698008
Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study
Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research. PMID:25393277
Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.
Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai
2014-01-01
To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.
A Crosslinked HA-Based Hydrogel Ameliorates Dry Eye Symptoms in Dogs
Williams, David L.; Mann, Brenda K.
2013-01-01
Keratoconjunctivitis sicca, commonly referred to as dry eye or KCS, can affect both humans and dogs. The standard of care in treating KCS typically includes daily administration of eye drops to either stimulate tear production or to hydrate and lubricate the corneal surface. Lubricating eye drops are often applied four to six times daily for the life of the patient. In order to reduce this dosing regimen yet still provides sufficient hydration and lubrication, we have developed a crosslinked hydrogel based on a modified, thiolated hyaluronic acid (HA), xCMHA-S. This xCMHA-S gel was found to have different viscosity and rheologic behavior than solutions of noncrosslinked HA. The gel was also able to increase tear breakup time in rabbits, indicating a stabilization of the tear film. Further, in a preliminary clinical study of dogs with KCS, the gel significantly reduced the symptoms associated with KCS within two weeks while only being applied twice daily. The reduction of symptoms combined with the low dosing regimen indicates that this gel may lead to both improved patient health and owner compliance in applying the treatment. PMID:23840213
Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce
2014-07-01
To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits.
Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce
2015-01-01
Purpose To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. Materials and Methods After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Results Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Conclusion Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits. PMID:24901976
2011-01-01
Background In humans, rapid eye movements (REM) density during REM sleep plays a prominent role in psychiatric diseases. Especially in depression, an increased REM density is a vulnerability marker for depression. In clinical practice and research measurement of REM density is highly standardized. In basic animal research, almost no tools are available to obtain and systematically evaluate eye movement data, although, this would create increased comparability between human and animal sleep studies. Methods We obtained standardized electroencephalographic (EEG), electromyographic (EMG) and electrooculographic (EOG) signals from freely behaving mice. EOG electrodes were bilaterally and chronically implanted with placement of the electrodes directly between the musculus rectus superior and musculus rectus lateralis. After recovery, EEG, EMG and EOG signals were obtained for four days. Subsequent to the implantation process, we developed and validated an Eye Movement scoring in Mice Algorithm (EMMA) to detect REM as singularities of the EOG signal, based on wavelet methodology. Results The distribution of wakefulness, non-REM (NREM) sleep and rapid eye movement (REM) sleep was typical of nocturnal rodents with small amounts of wakefulness and large amounts of NREM sleep during the light period and reversed proportions during the dark period. REM sleep was distributed correspondingly. REM density was significantly higher during REM sleep than NREM sleep. REM bursts were detected more often at the end of the dark period than the beginning of the light period. During REM sleep REM density showed an ultradian course, and during NREM sleep REM density peaked at the beginning of the dark period. Concerning individual eye movements, REM duration was longer and amplitude was lower during REM sleep than NREM sleep. The majority of single REM and REM bursts were associated with micro-arousals during NREM sleep, but not during REM sleep. Conclusions Sleep-stage specific distributions of REM in mice correspond to human REM density during sleep. REM density, now also assessable in animal models through our approach, is increased in humans after acute stress, during PTSD and in depression. This relationship can now be exploited to match animal models more closely to clinical situations, especially in animal models of depression. PMID:22047102
Attention to eye contact in the West and East: autonomic responses and evaluative ratings.
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.
Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627
NASA Astrophysics Data System (ADS)
Rinawati, M.; Triastuti, J.; Pursetyo, K. T.
2018-04-01
The cornea is a refractive element of the eye that serves to continue the stimulation of light into the eye it has a clear, transparent, elastic and relatively thick tissue. Factors caused corneal blindness, are dystrophy, keratoconus, corneal scaring. Hydrogels can be made from polysaccharide derivatives that have gelation properties such as iota carrageenan. Therefore, it is a need to develop composite hydrogel based collagen-iota carragenan as an engineeried corneal tissue with high elasticity and hydration properties. Collagen hydrogel has a maximum water content an has equlibrium up to 40 %, less than the human cornea, 81 % and under normal hydration conditions, the human cornea can transmit 87 % of visible light. In addition, the refractive index on the surface of the cornea with air is 1.375-1.380. Based on this study, it is necessary to conduct research on the development and composition of hydrogel composite collagen-iota carrageen hydrogen based on. The best result was K5 (5:5) treatment, which has the equilibrium water content of 87.07 % and viscosity of 10.7346 Pa.s.
Spering, Miriam; Carrasco, Marisa
2012-05-30
Feature-based attention enhances visual processing and improves perception, even for visual features that we are not aware of. Does feature-based attention also modulate motor behavior in response to visual information that does or does not reach awareness? Here we compare the effect of feature-based attention on motion perception and smooth-pursuit eye movements in response to moving dichoptic plaids--stimuli composed of two orthogonally drifting gratings, presented separately to each eye--in human observers. Monocular adaptation to one grating before the presentation of both gratings renders the adapted grating perceptually weaker than the unadapted grating and decreases the level of awareness. Feature-based attention was directed to either the adapted or the unadapted grating's motion direction or to both (neutral condition). We show that observers were better at detecting a speed change in the attended than the unattended motion direction, indicating that they had successfully attended to one grating. Speed change detection was also better when the change occurred in the unadapted than the adapted grating, indicating that the adapted grating was perceptually weaker. In neutral conditions, perception and pursuit in response to plaid motion were dissociated: While perception followed one grating's motion direction almost exclusively (component motion), the eyes tracked the average of both gratings (pattern motion). In attention conditions, perception and pursuit were shifted toward the attended component. These results suggest that attention affects perception and pursuit similarly even though only the former reflects awareness. The eyes can track an attended feature even if observers do not perceive it.
Dog Breed Differences in Visual Communication with Humans
Konno, Akitsugu; Romero, Teresa; Inoue-Murayama, Miho; Saito, Atsuko; Hasegawa, Toshikazu
2016-01-01
Domestic dogs (Canis familiaris) have developed a close relationship with humans through the process of domestication. In human-dog interactions, eye contact is a key element of relationship initiation and maintenance. Previous studies have suggested that canine ability to produce human-directed communicative signals is influenced by domestication history, from wolves to dogs, as well as by recent breed selection for particular working purposes. To test the genetic basis for such abilities in purebred dogs, we examined gazing behavior towards humans using two types of behavioral experiments: the ‘visual contact task’ and the ‘unsolvable task’. A total of 125 dogs participated in the study. Based on the genetic relatedness among breeds subjects were classified into five breed groups: Ancient, Herding, Hunting, Retriever-Mastiff and Working). We found that it took longer time for Ancient breeds to make an eye-contact with humans, and that they gazed at humans for shorter periods of time than any other breed group in the unsolvable situation. Our findings suggest that spontaneous gaze behavior towards humans is associated with genetic similarity to wolves rather than with recent selective pressure to create particular working breeds. PMID:27736990
Human vision-based algorithm to hide defective pixels in LCDs
NASA Astrophysics Data System (ADS)
Kimpe, Tom; Coulier, Stefaan; Van Hoey, Gert
2006-02-01
Producing displays without pixel defects or repairing defective pixels is technically not possible at this moment. This paper presents a new approach to solve this problem: defects are made invisible for the user by using image processing algorithms based on characteristics of the human eye. The performance of this new algorithm has been evaluated using two different methods. First of all the theoretical response of the human eye was analyzed on a series of images and this before and after applying the defective pixel compensation algorithm. These results show that indeed it is possible to mask a defective pixel. A second method was to perform a psycho-visual test where users were asked whether or not a defective pixel could be perceived. The results of these user tests also confirm the value of the new algorithm. Our "defective pixel correction" algorithm can be implemented very efficiently and cost-effectively as pixel-dataprocessing algorithms inside the display in for instance an FPGA, a DSP or a microprocessor. The described techniques are also valid for both monochrome and color displays ranging from high-quality medical displays to consumer LCDTV applications.
NASA Astrophysics Data System (ADS)
Poddar, Raju; Zawadzki, Robert J.; Cortés, Dennis E.; Mannis, Mark J.; Werner, John S.
2015-06-01
We present in vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-scleral junction and sclera were imaged with swept source phase-variance optical coherence angiography and compared with slit lamp images from the same eyes of normal subjects. Different features of the rich vascular system in the conjunctiva and episclera were visualized and described. This system can be used as a potential tool for ophthalmological research to determine changes in the outflow system, which may be helpful for identification of abnormalities that lead to glaucoma.
High-speed adaptive optics for imaging of the living human eye
Yu, Yongxin; Zhang, Tianjiao; Meadway, Alexander; Wang, Xiaolin; Zhang, Yuhua
2015-01-01
The discovery of high frequency temporal fluctuation of human ocular wave aberration dictates the necessity of high speed adaptive optics (AO) correction for high resolution retinal imaging. We present a high speed AO system for an experimental adaptive optics scanning laser ophthalmoscope (AOSLO). We developed a custom high speed Shack-Hartmann wavefront sensor and maximized the wavefront detection speed based upon a trade-off among the wavefront spatial sampling density, the dynamic range, and the measurement sensitivity. We examined the temporal dynamic property of the ocular wavefront under the AOSLO imaging condition and improved the dual-thread AO control strategy. The high speed AO can be operated with a closed-loop frequency up to 110 Hz. Experiment results demonstrated that the high speed AO system can provide improved compensation for the wave aberration up to 30 Hz in the living human eye. PMID:26368408
Biobanking of Human Retinas: The Next Big Leap for Eye Banks?
Lužnik, Zala; Parekh, Mohit; Bertolin, Marina; Griffoni, Carlo; Ponzin, Diego
2015-01-01
Summary Retinal degenerative diseases are one of the main clinical causes of incurable and severe visional impairment. Thus, extensive research effort is put into the development of new causal therapeutic options. Promisingly, a number of studies showed regenerative capacity in specific retinal regions (the ciliary epithelium, retinal pigmented epithelium, iris, and Müller glia cells). However, most recent research studies are based on animal models or in vitro cultured cells, probably because of the limited availability of human posterior eye tissues (vitreous, retina, and choroid). To address this, we showed in our previous reports that eye banks with large numbers of globes collected yearly could set up biorepositories/biobanks where these precious tissues are isolated, quality controlled, and finally stored for scientists and clinicians wanting to access human tissues and test their own hypotheses. These precious human posterior eye tissues could be used for further research purposes, epidemiological studies, and target validation of newly developed drugs. In addition, this could be a promising and challenging option to retrieve potential retinal stem and progenitor cells from different parts of the retina and could be a breakthrough in the future delivery of ex vivo prepared customized (histocompatible) retinal tissue on scaffolds for transplantation purposes. In this Perspective, we will consider how the biorepositories could influence the future strategies for retinal stem cell therapies. Significance Retinal degenerative diseases are one of the main causes of severe vision impairment and regenerative medicine is attracting much attention as a potential therapy. Although highly desirable, the reactivation and proliferation of endogenous stem cells in vivo is not sufficient to generate enough cells to restore visual function after retinal injury. Thus, the replacement of exogenously derived normal donor cells is a promising solution. The challenge is to develop therapies with sufficient amounts of cells being harvested or expanded from donor tissues. Eye banks could overcome this issue by harvesting endogenous adult retinal stem cells from different donors. PMID:26032747
Contrast-based sensorless adaptive optics for retinal imaging
Zhou, Xiaolin; Bedggood, Phillip; Bui, Bang; Nguyen, Christine T.O.; He, Zheng; Metha, Andrew
2015-01-01
Conventional adaptive optics ophthalmoscopes use wavefront sensing methods to characterize ocular aberrations for real-time correction. However, there are important situations in which the wavefront sensing step is susceptible to difficulties that affect the accuracy of the correction. To circumvent these, wavefront sensorless adaptive optics (or non-wavefront sensing AO; NS-AO) imaging has recently been developed and has been applied to point-scanning based retinal imaging modalities. In this study we show, for the first time, contrast-based NS-AO ophthalmoscopy for full-frame in vivo imaging of human and animal eyes. We suggest a robust image quality metric that could be used for any imaging modality, and test its performance against other metrics using (physical) model eyes. PMID:26417525
The effects of two different types of bandage contact lenses on the healthy canine eye.
Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse
2018-02-06
To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.
Monocular zones in stereoscopic scenes: A useful source of information for human binocular vision?
NASA Astrophysics Data System (ADS)
Harris, Julie M.
2010-02-01
When an object is closer to an observer than the background, the small differences between right and left eye views are interpreted by the human brain as depth. This basic ability of the human visual system, called stereopsis, lies at the core of all binocular three-dimensional (3-D) perception and related technological display development. To achieve stereopsis, it is traditionally assumed that corresponding locations in the right and left eye's views must first be matched, then the relative differences between right and left eye locations are used to calculate depth. But this is not the whole story. At every object-background boundary, there are regions of the background that only one eye can see because, in the other eye's view, the foreground object occludes that region of background. Such monocular zones do not have a corresponding match in the other eye's view and can thus cause problems for depth extraction algorithms. In this paper I will discuss evidence, from our knowledge of human visual perception, illustrating that monocular zones do not pose problems for our human visual systems, rather, our visual systems can extract depth from such zones. I review the relevant human perception literature in this area, and show some recent data aimed at quantifying the perception of depth from monocular zones. The paper finishes with a discussion of the potential importance of considering monocular zones, for stereo display technology and depth compression algorithms.
76 FR 10041 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Clinical... agreement applications. Place: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852. (Telephone...
76 FR 2914 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-18
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... National Eye Institute, including consideration of personnel qualifications and performances, and the... invasion of personal privacy. Name of Committee: Board of Scientific Counselors, National Eye Institute...
75 FR 52762 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Institutional... Officer, Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635...
77 FR 71428 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-30
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical..., Scientific Review Officer, Division of Extramural Research, National Eye Institute, National Institutes of...
Bélanger, Julie; Johns, Timothy
2008-09-01
Human and ecosystem health converge around biological diversity issues. Cultivated and wild plants as food and medicine make essential contributions to human health, which in turn provides rationales for conservation. While wild and cultivated plant diversity reasonably facilitates dietary diversity and positive health outcomes, the challenges of demonstrating this relationship limit its impact in concept, policy, and practice. We present a rationale for testing the dietary contribution of biological diversity to improved eye health as a case study based on existing phytochemical, pharmacological, and clinical knowledge. We consider the empirical evidence needed to substantiate, interpret, and apply this relationship at a population and ecosystem level within a unified research framework. Epidemiological data strongly support the prevention of childhood vitamin A deficiency blindness, cataract, and age-related macular degeneration by fruit and vegetable consumption. Phytonutrients, including the carotenoids lutein and zeaxanthin, protect the eye from oxidative stress and harmful light exposure. Laboratory, community, and population level research should prioritize food composition of dietary plants from both agriculture and the wild. Intervention studies, focus groups, and transmission of knowledge of local species and varieties within communities will further interpretation of epidemiological data. Population-based studies combining clinical data and measures of access and consumption of biological diversity are key to demonstrating the important relationships among biodiversity, dietary diversity, and health outcomes.
Soft, Conformal Bioelectronics for a Wireless Human-Wheelchair Interface
Mishra, Saswat; Norton, James J. S.; Lee, Yongkuk; Lee, Dong Sup; Agee, Nicolas; Chen, Yanfei; Chun, Youngjae; Yeo, Woon-Hong
2017-01-01
There are more than 3 million people in the world whose mobility relies on wheelchairs. Recent advancement on engineering technology enables more intuitive, easy-to-use rehabilitation systems. A human-machine interface that uses non-invasive, electrophysiological signals can allow a systematic interaction between human and devices; for example, eye movement-based wheelchair control. However, the existing machine-interface platforms are obtrusive, uncomfortable, and often cause skin irritations as they require a metal electrode affixed to the skin with a gel and acrylic pad. Here, we introduce a bioelectronic system that makes dry, conformal contact to the skin. The mechanically comfortable sensor records high-fidelity electrooculograms, comparable to the conventional gel electrode. Quantitative signal analysis and infrared thermographs show the advantages of the soft biosensor for an ergonomic human-machine interface. A classification algorithm with an optimized set of features shows the accuracy of 94% with five eye movements. A Bluetooth-enabled system incorporating the soft bioelectronics demonstrates a precise, hands-free control of a robotic wheelchair via electrooculograms. PMID:28152485
Lachrymal Gland Basal Cell Adenocarcinoma in a Ferret (Mustela putorius furo).
Chambers, J K; Nakamori, T; Kishimoto, T E; Nakata, M; Miwa, Y; Nakayama, H; Uchida, K
2016-01-01
A 1 cm diameter mass was detected in the caudal superotemporal area of the left eye of a 6-year-old neutered male ferret (Mustela putorius furo). The mass and the left eye were removed surgically. Microscopical examination revealed a tumour of the adnexal gland of the eye that had invaded the surrounding ocular muscle. The tumour was composed of basal-type epithelial cells arranged in a solid, or occasionally tubular, pattern. Immunohistochemically, the tumour cells expressed cytokeratin and p63, but not smooth muscle actin. Based on these findings, the tumour was diagnosed as a basal cell adenocarcinoma of the lachrymal gland. In addition to the tumour, the retina of the left eye was detached and folded at the centre of the globe. This is the first report of a non-human case of basal cell adenocarcinoma of the lachrymal gland. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mucin-type O-glycans in Tears of Normal Subjects and Patients with Non-Sjögren’s Dry Eye
Guzman-Aranguez, Ana; Mantelli, Flavio; Argüeso, Pablo
2009-01-01
Purpose O-linked carbohydrates (O-glycans) contribute to the hydrophilic character of mucins in mucosal tissues. This study aimed to identify the repertoire of O-glycans in the tear film, and the glycosyltransferases associated with their biosynthesis, in normal subjects and patients with non-Sjögren’s dry eye. Methods Human tear fluid was collected from the inferior conjunctival fornix. O-glycans were released by hydrazinolysis, labeled with 2-aminobenzamide, and analyzed by fluorometric, high-performance liquid chromatography (HPLC) coupled with exoglycosidase digestions. O-glycan structures identified in tears were related to potential biosynthetic pathways in human conjunctival epithelium using a glycogene microarray database. Lectin-binding analyses were performed using agglutinins from Arachis hypogaea, Maackia amurensis, and Sambucus nigra. Results The O-glycan profile of human tears consisted primarily of core 1 (Galβ1-3GalNAcα1-Ser/Thr)-based structures. Mono-sialyl O-glycans represented approximately 66% of the glycan pool, being α2-6-sialyl core 1 the predominant O-glycan structure in human tears (48%). Four families of glycosyltranferases potentially related to the biosynthesis of these structures were identified in human conjunctiva. These included thirteen polypeptide-GalNAc-transferases (GALNT), the core 1 β-3-galactosyltransferase (T-synthase), three α2-6-sialyltransferases (ST6GalNAc), and two α2-3-sialyltransferases (ST3Gal). No significant differences in total amount of O-glycans were detected between tears of normal subjects and dry eye patients, by HPLC and lectin blot. Likewise, no differences in glycosyltransferase expression were found by glycogene microarray. Conclusions This study identifies the most common mucin-type O-glycans in human tears and their expected biosynthetic pathways in ocular surface epithelia. Patients with non-Sjögren’s dry eye show no alterations in composition and amount of O-glycans in the tear fluid. PMID:19407012
2003-01-22
One concern about human adaptation to space is how returning from the microgravity of orbit to Earth can affect an astronaut's ability to fly safely. There are monitors and infrared video cameras to measure eye movements without having to affect the crew member. A computer screen provides moving images which the eye tracks while the brain determines what it is seeing. A video camera records movement of the subject's eyes. Researchers can then correlate perception and response. Test subjects perceive different images when a moving object is covered by a mask that is visible or invisible (above). Early results challenge the accepted theory that smooth pursuit -- the fluid eye movement that humans and primates have -- does not involve the higher brain. NASA results show that: Eye movement can predict human perceptual performance, smooth pursuit and saccadic (quick or ballistic) movement share some signal pathways, and common factors can make both smooth pursuit and visual perception produce errors in motor responses.
Understanding Visible Perception
NASA Technical Reports Server (NTRS)
2003-01-01
One concern about human adaptation to space is how returning from the microgravity of orbit to Earth can affect an astronaut's ability to fly safely. There are monitors and infrared video cameras to measure eye movements without having to affect the crew member. A computer screen provides moving images which the eye tracks while the brain determines what it is seeing. A video camera records movement of the subject's eyes. Researchers can then correlate perception and response. Test subjects perceive different images when a moving object is covered by a mask that is visible or invisible (above). Early results challenge the accepted theory that smooth pursuit -- the fluid eye movement that humans and primates have -- does not involve the higher brain. NASA results show that: Eye movement can predict human perceptual performance, smooth pursuit and saccadic (quick or ballistic) movement share some signal pathways, and common factors can make both smooth pursuit and visual perception produce errors in motor responses.
Indentation and needle insertion properties of the human eye
Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G
2014-01-01
Purpose Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. Methods An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. Results The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (P<0.001). Needle insertion through the anterior sclera (adjacent to the limbus) and posterior sclera (adjacent to the optic nerve) required the greatest amount of force (0.954 and 1.005 N, respectively). The force required to penetrate the central cornea (0.518 N) was significantly lower than all other areas except the midline sclera (0.700 N) Conclusion These data form the basis for further research into the development of a tissue-mimicking human eye construct with potential utility as a model for use in ophthalmology research and surgical teaching. PMID:24810571
Automated analysis of angle closure from anterior chamber angle images.
Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin
2014-10-21
To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu
2016-05-01
In spite the fact that a very small human body surface area is comprised by the eye, its wounds due to detonation have recently been dramatically amplified. Although many efforts have been devoted to measure injury of the globe, there is still a lack of knowledge on the injury mechanism due to Primary Blast Wave (PBW). The goal of this study was to determine the stresses and deformations of the human eye components, including the cornea, aqueous, iris, ciliary body, lens, vitreous, retina, sclera, optic nerve, and muscles, attributed to PBW induced by trinitrotoluene (TNT) explosion via a Lagrangian-Eulerian computational coupling model. Magnetic Resonance Imaging (MRI) was employed to establish a Finite Element (FE) model of the human eye according to a normal human eye. The solid components of the eye were modelled as Lagrangian mesh, while an explosive TNT, air domain, and aqueous were modelled using Arbitrary Lagrangian-Eulerian (ALE) mesh. Nonlinear dynamic FE simulations were accomplished using the explicit FE code, namely LS-DYNA. In order to simulate the blast wave generation, propagation, and interaction with the eye, the ALE formulation with Jones-Wilkins-Lee (JWL) equation defining the explosive material were employed. The results revealed a peak stress of 135.70kPa brought about by detonation upsurge on the cornea at the distance of 25cm. The highest von Mises stresses were observed on the sclera (267.3kPa), whereas the lowest one was seen on the vitreous body (0.002kPa). The results also showed a relatively high resultant displacement for the macula as well as a high variation for the radius of curvature for the cornea and lens, which can result in both macular holes, optic nerve damage and, consequently, vision loss. These results may have implications not only for understanding the value of stresses and strains in the human eye components but also giving an outlook about the process of PBW triggers damage to the eye. Copyright © 2016 Elsevier Ltd. All rights reserved.
75 FR 74068 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-30
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; U10 Teleconference... applications. Place: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852. (Telephone Confence Call...
77 FR 24727 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-25
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Trials.... Schaffner, Ph.D., Chief, Scientific Review Branch, Division of Extramural Research, National Eye Institute...
76 FR 24498 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...
76 FR 66732 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Genomic Research.... Schaffner, PhD, Chief, Scientific Review Officer, Division of Extramural Research, National Eye Institute...
77 FR 43097 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Epidemiology... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
78 FR 62639 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical and.... Contact Person: Brian Hoshaw, Ph.D., Scientific Review Officer, National Eye Institute, National...
75 FR 58410 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-24
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NIH Joint Neuroscience... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
77 FR 73666 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Trial... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
76 FR 71350 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-17
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Pediatric Vision..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...
77 FR 22581 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-16
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Loan Repayment... program applications. Place: National Eye Institute, National Institutes of Health, 5635 Fishers Lane...
75 FR 26968 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Loan Repayment... applications. Place: National Eye Institute, 5635 Fishers Lane, Bethesda, MD (Virtual Meeting). Contact Person...
78 FR 62640 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Bioinformatics..., Division of Extramural Research, National Eye Institute, 5635 Fishers Lane, Suite 1300, MSC 9300, Bethesda...
76 FR 46822 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel... Review Officer, Division of Extramural Research, National Eye Institute, National Institutes of Health...
78 FR 37556 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Epidemiology and... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
76 FR 39406 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Research Program... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
76 FR 13197 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Clinical... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...
77 FR 64525 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Career Development... Schaffner, Ph.D., Chief, Scientific Review Officer, Division of Extramural Research, National Eye Institute...
75 FR 55806 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, RO1 Epidemiology... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
75 FR 46951 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-04
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...
LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE
In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...
Research on metallic material defect detection based on bionic sensing of human visual properties
NASA Astrophysics Data System (ADS)
Zhang, Pei Jiang; Cheng, Tao
2018-05-01
Due to the fact that human visual system can quickly lock the areas of interest in complex natural environment and focus on it, this paper proposes an eye-based visual attention mechanism by simulating human visual imaging features based on human visual attention mechanism Bionic Sensing Visual Inspection Model Method to Detect Defects of Metallic Materials in the Mechanical Field. First of all, according to the biologically visually significant low-level features, the mark of defect experience marking is used as the intermediate feature of simulated visual perception. Afterwards, SVM method was used to train the advanced features of visual defects of metal material. According to the weight of each party, the biometrics detection model of metal material defect, which simulates human visual characteristics, is obtained.
Does direct human eye contact function as a warning cue for domestic sheep (Ovis aries)?
Beausoleil, Ngaio J; Stafford, Kevin J; Mellor, David J
2006-08-01
Direct eye contact may function as a warning cue during interspecific interactions, and human staring has been shown to influence the behavior of many species. The authors used an arena test to assess whether human staring altered the behavior of domestic sheep (Ovis aries) compared with no human eye contact. Sheep glanced at the staring human's face more often in the first 2 min of the test, indicating that they perceived a difference between the human stimuli. Staring also elicited more locomotor activity and urination than averted gaze. However, there were no differences in fear-related behaviors, suggesting that a staring human did not represent a greater immediate threat than a nonwatching human. These results imply that human staring is a warning cue for domestic sheep, but no more. Without further reinforcement, sheep quickly habituated to the warning cue. ((c) 2006 APA, all rights reserved).
Atmospheric effects on laser eye safety and damage to instrumentation
NASA Astrophysics Data System (ADS)
Zilberman, Arkadi; Kopeika, Natan S.
2017-10-01
Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser detector/eye hazard depends on the interaction between the laser beam and the media in which it traverses. The environmental conditions including terrain features, atmospheric particulate and water content, and turbulence, may alter the laser's effect on the detector/eye. It is possible to estimate the performance of an electro-optical system as long as the atmospheric propagation of the laser beam can be adequately modeled. More recent experiments and modeling of atmospheric optics phenomena such as inner scale effect, aperture averaging, atmospheric attenuation in NIR-SWIR, and Cn2 modeling justify an update of previous eye/detector safety modeling. In the present work, the influence of the atmospheric channel on laser safety for personnel and instrumentation is shown on the basis of theoretical and experimental data of laser irradiance statistics for different atmospheric conditions. A method for evaluating the probability of damage and hazard distances associated with the use of laser systems in a turbulent atmosphere operating in the visible and NIR-SWIR portions of the electromagnetic spectrum is presented. It can be used as a performance prediction model for directed energy engagement of ground-based or air-based systems.
Eberwein, Philipp; Hansen, Lutz L; Agostini, Hansjürgen T
2005-02-01
JC virus (JCV) is a human polyomavirus that exists in at least eight different genotypes as a result of coevolution with different human populations all over the world. Well adapted to its host, it usually persists in the kidneys and possibly the brain. If the host becomes immunodeficient, JCV can cause the fatal demyelinating disease progressive multifocal leukoencephalopathy (PML). There is increasing evidence that JCV is transactivated by cytomegalovirus (CMV) and the human immunodeficiency virus (HIV). Both CMV and HIV can infect the retina of acquired immunodeficiency syndrome (AIDS) patients, causing severe necrosis in the case of CMV retinitis or a mild HIV-associated vasculopathy, with bleeding and cotton wool spots. The authors therefore investigated by polymerase chain reaction (PCR) whether DNA of these three viruses was detectable in paraffin-embedded eyes of AIDS patients with a clinical history of CMV retinitis. From a total of 65 eyes, JCV was detected in 21 (32%). Thirty-six (55%) were positive for CMV and 6 (9%) for proviral DNA of HIV. JCV and CMV were found in 13 eyes, JCV and HIV in 3 eyes, CMV and HIV in 1 eye, and DNA from all three viruses in 1 eye. The JCV genotypes were types 1A, 2A, 2E, 3, and 4. In 21 eyes of patients without AIDS, only one sample was JCV positive. In conclusion, JCV DNA can be detected in ocular tissue of AIDS patients at a significantly higher level than in eyes of nonimmunosuppressed patients. Further investigations will help to decide if JCV contributes to the retinopathy caused by CMV and HIV.
Abnormal spatial frequency channels in esotropic cats.
Holopigian, K; Blake, R
1984-01-01
A noise masking paradigm was used to measure spatial tuning for the deviating and nondeviating eyes of two esotropic cats and for one eye of a control cat. With increasing noise contrast, masking grew more slowly for both the deviating and the nondeviating eyes of the esotropic cats than for the control cat; apparently, contrast coding is impaired for both eyes of the esotropic cats. Masking with band-reject filtered noise indicated that detection channels for either eye of the esotropic cats were twice as broadly tuned as those for the control cat. In a subsequent experiment, the spatial tuning characteristics of two human esotropes were found to be normal, indicating a fundamental difference between human esotropia and esotropia induced in cats by the section of an eye muscle.
Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang
2014-01-01
An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.
An ocular biomechanic model for dynamic simulation of different eye movements.
Iskander, J; Hossny, M; Nahavandi, S; Del Porto, L
2018-04-11
Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biomechanic ocular models that are easily integrated into the available musculoskeletal models. The model was previously used to simulate eye-head coordination. The models are used to simulate and analyse eye movements. The proposed models are based on physiological and kinematic properties of the human eye. They incorporate an eye-globe, orbital suspension tissues and six muscles with their connective tissues (pulleys). Pulleys were incorporated in rectus and inferior oblique muscles. The two proposed models are the passive pulleys and the active pulleys models. Dynamic simulations of different eye movements, including fixation, saccade and smooth pursuit, are performed to validate both models. The resultant force-length curves of the models were similar to the experimental data. The simulation results show that the proposed models are suitable to generate eye movement simulations with results comparable to other musculoskeletal models. The maximum kinematic root mean square error (RMSE) is 5.68° and 4.35° for the passive and active pulley models, respectively. The analysis of the muscle forces showed realistic muscle activation with increased muscle synergy in the active pulley model. Copyright © 2018 Elsevier Ltd. All rights reserved.
See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction
XU, TIAN (LINGER); ZHANG, HUI; YU, CHEN
2016-01-01
We focus on a fundamental looking behavior in human-robot interactions – gazing at each other’s face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user’s face as a response to the human’s gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot’s gaze toward the human partner’s face in real time and then analyzed the human’s gaze behavior as a response to the robot’s gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot’s face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained. PMID:28966875
Common determinants of body size and eye size in chickens from an advanced intercross line.
Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; Fan, Qiao; Saw, Seang Mei; Guggenheim, Jeremy A
2009-06-15
Myopia development is characterised by an increased axial eye length. Therefore, identifying factors that influence eye size may provide new insights into the aetiology of myopia. In humans, axial length is positively correlated to height and weight, and in mice, eye weight is positively correlated with body weight. The purpose of this study was to examine the relationship between eye size and body size in chickens from a genetic cross in which alleles with major effects on eye and body size were segregating. Chickens from a cross between a layer line (small body size and eye size) and a broiler line (large body and eye size) were interbred for 10 generations so that alleles for eye and body size would have the chance to segregate independently. At 3 weeks of age, 510 chicks were assessed using in vivo high resolution A-scan ultrasonography and keratometry. Equatorial eye diameter and eye weight were measured after enucleation. The variations in eye size parameters that could be explained by body weight (BW), body length (BL), head width (HW) and sex were examined using multiple linear regression. It was found that BW, BL and HW and sex together predicted 51-56% of the variation in eye weight, axial length, corneal radius, and equatorial eye diameter. By contrast, the same variables predicted only 22% of the variation in lens thickness. After adjusting for sex, the three body size parameters predicted 45-49% of the variation in eye weight, axial length, corneal radius, and eye diameter, but only 0.4% of the variation in lens thickness. In conclusion, about half of the variation in eye size in the chickens of this broiler-layer advanced intercross line is likely to be determined by pleiotropic genes that also influence body size. Thus, mapping the quantitative trait loci (QTL) that determine body size may be useful in understanding the genetic determination of eye size (a logical inference of this result is that the 20 or more genetic variants that have recently been shown to influence human height may also be found to influence axial eye length). Furthermore, adjusting for body size will be essential in mapping pure eye size QTL in this chicken population, and may also have value in mapping eye size QTL in humans.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Announcement of National Eye... intended to inform potential applicants that the National Eye Institute (NEI) is participating in PA-11-347... biology related to eye health and eye disease treatments. For more information about the research and...
76 FR 3917 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-21
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Training Grants. Date...: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852 (Virtual Meeting). Contact Person: Daniel R...
78 FR 28233 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute..., National Eye Institute. The meeting will be closed to the public in accordance with the provisions set... individual intramural programs and projects conducted by the National Eye Institute, including consideration...
78 FR 9403 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Core Grant (P30... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
77 FR 63845 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-17
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI-RFA Stem Cell... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
75 FR 33628 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel... Review Officer, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC...
77 FR 14816 - National Eye Institute Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES NATIONAL INSTITUTES OF HEALTH National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; Vision Research Grant..., National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300, 301-451...
75 FR 10489 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Grant..., Division of Extramural Research, National Eye Institute, 5635 Fishers Lane, Suite 1300, Msc 9300, Bethesda...
75 FR 8971 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-26
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI K99 Grant.... Kenshalo, PhD, Scientific Review Officer, National Eye Institute, National Institutes of Health, 5635...
78 FR 15021 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Pathways to... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...
77 FR 40367 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-09
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Washington, DC 20015. Contact Person: Daniel R. Kenshalo, Ph.D., Scientific Review Officer, National Eye...
75 FR 64311 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-19
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NIH Training Grants..., National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300. 301-451...
78 FR 46593 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI K99 Review. Date... Person: Brian Hoshaw, Ph.D. Scientific Review Officer, National Eye Institute, National Institutes of...
Vanderwert, Ross E; Westerlund, Alissa; Montoya, Lina; McCormick, Sarah A; Miguel, Helga O; Nelson, Charles A
2015-10-01
Previous studies in infants have shown that face-sensitive components of the ongoing electroencephalogram (the event-related potential, or ERP) are larger in amplitude to negative emotions (e.g., fear, anger) versus positive emotions (e.g., happy). However, it is still unclear whether the negative emotions linked with the face or the negative emotions alone contribute to these amplitude differences. We simultaneously recorded infant looking behaviors (via eye-tracking) and face-sensitive ERPs while 7-month-old infants viewed human faces or animals displaying happy, fear, or angry expressions. We observed that the amplitude of the N290 was greater (i.e., more negative) to angry animals compared to happy or fearful animals; no such differences were obtained for human faces. Eye-tracking data highlighted the importance of the eye region in processing emotional human faces. Infants that spent more time looking to the eye region of human faces showing fearful or angry expressions had greater N290 or P400 amplitudes, respectively. © 2014 Wiley Periodicals, Inc.
Human vision is determined based on information theory.
Delgado-Bonal, Alfonso; Martín-Torres, Javier
2016-11-03
It is commonly accepted that the evolution of the human eye has been driven by the maximum intensity of the radiation emitted by the Sun. However, the interpretation of the surrounding environment is constrained not only by the amount of energy received but also by the information content of the radiation. Information is related to entropy rather than energy. The human brain follows Bayesian statistical inference for the interpretation of visual space. The maximization of information occurs in the process of maximizing the entropy. Here, we show that the photopic and scotopic vision absorption peaks in humans are determined not only by the intensity but also by the entropy of radiation. We suggest that through the course of evolution, the human eye has not adapted only to the maximum intensity or to the maximum information but to the optimal wavelength for obtaining information. On Earth, the optimal wavelengths for photopic and scotopic vision are 555 nm and 508 nm, respectively, as inferred experimentally. These optimal wavelengths are determined by the temperature of the star (in this case, the Sun) and by the atmospheric composition.
Human vision is determined based on information theory
NASA Astrophysics Data System (ADS)
Delgado-Bonal, Alfonso; Martín-Torres, Javier
2016-11-01
It is commonly accepted that the evolution of the human eye has been driven by the maximum intensity of the radiation emitted by the Sun. However, the interpretation of the surrounding environment is constrained not only by the amount of energy received but also by the information content of the radiation. Information is related to entropy rather than energy. The human brain follows Bayesian statistical inference for the interpretation of visual space. The maximization of information occurs in the process of maximizing the entropy. Here, we show that the photopic and scotopic vision absorption peaks in humans are determined not only by the intensity but also by the entropy of radiation. We suggest that through the course of evolution, the human eye has not adapted only to the maximum intensity or to the maximum information but to the optimal wavelength for obtaining information. On Earth, the optimal wavelengths for photopic and scotopic vision are 555 nm and 508 nm, respectively, as inferred experimentally. These optimal wavelengths are determined by the temperature of the star (in this case, the Sun) and by the atmospheric composition.
Human vision is determined based on information theory
Delgado-Bonal, Alfonso; Martín-Torres, Javier
2016-01-01
It is commonly accepted that the evolution of the human eye has been driven by the maximum intensity of the radiation emitted by the Sun. However, the interpretation of the surrounding environment is constrained not only by the amount of energy received but also by the information content of the radiation. Information is related to entropy rather than energy. The human brain follows Bayesian statistical inference for the interpretation of visual space. The maximization of information occurs in the process of maximizing the entropy. Here, we show that the photopic and scotopic vision absorption peaks in humans are determined not only by the intensity but also by the entropy of radiation. We suggest that through the course of evolution, the human eye has not adapted only to the maximum intensity or to the maximum information but to the optimal wavelength for obtaining information. On Earth, the optimal wavelengths for photopic and scotopic vision are 555 nm and 508 nm, respectively, as inferred experimentally. These optimal wavelengths are determined by the temperature of the star (in this case, the Sun) and by the atmospheric composition. PMID:27808236
The Vestibular System and Human Dynamic Space Orientation
NASA Technical Reports Server (NTRS)
Meiry, J. L.
1966-01-01
The motion sensors of the vestibular system are studied to determine their role in human dynamic space orientation and manual vehicle control. The investigation yielded control models for the sensors, descriptions of the subsystems for eye stabilization, and demonstrations of the effects of motion cues on closed loop manual control. Experiments on the abilities of subjects to perceive a variety of linear motions provided data on the dynamic characteristics of the otoliths, the linear motion sensors. Angular acceleration threshold measurements supplemented knowledge of the semicircular canals, the angular motion sensors. Mathematical models are presented to describe the known control characteristics of the vestibular sensors, relating subjective perception of motion to objective motion of a vehicle. The vestibular system, the neck rotation proprioceptors and the visual system form part of the control system which maintains the eye stationary relative to a target or a reference. The contribution of each of these systems was identified through experiments involving head and body rotations about a vertical axis. Compensatory eye movements in response to neck rotation were demonstrated and their dynamic characteristics described by a lag-lead model. The eye motions attributable to neck rotations and vestibular stimulation obey superposition when both systems are active. Human operator compensatory tracking is investigated in simple vehicle orientation control system with stable and unstable controlled elements. Control of vehicle orientation to a reference is simulated in three modes: visual, motion and combined. Motion cues sensed by the vestibular system through tactile sensation enable the operator to generate more lead compensation than in fixed base simulation with only visual input. The tracking performance of the human in an unstable control system near the limits of controllability is shown to depend heavily upon the rate information provided by the vestibular sensors.
NASA Astrophysics Data System (ADS)
Santiago-Alvarado, A.; Cruz-Félix, A.; Hernández Méndez, A.; Pérez-Maldonado, Y.; Domínguez-Osante, C.
2015-05-01
Tunable lenses have attracted much attention due to their potential applications in such areas like machine vision, laser projection, ophthalmology, etc. In this work we present the design of a tunable opto-mechatronic system capable of focusing and to regulate the entrance illumination that mimics the performance made by the iris and the crystalline lens of the human eye. A solid elastic lens made of PDMS has been used in order to mimic the crystalline lens and an automatic diaphragm has been used to mimic the iris of the human eye. Also, a characterization of such system has been performed with standard values of luminosity for the human eye have been taken into account to calibrate and to validate the entrance illumination levels to the overall optical system.
Improved eye- and skin-color prediction based on 8 SNPs.
Hart, Katie L; Kimura, Shey L; Mushailov, Vladimir; Budimlija, Zoran M; Prinz, Mechthild; Wurmbach, Elisa
2013-06-01
To improve the 7-plex system to predict eye and skin color by increasing precision and detailed phenotypic descriptions. Analysis of an eighth single nucleotide polymorphism (SNP), rs12896399 (SLC24A4), showed a statistically significant association with human eye color (P=0.007) but a rather poor strength of agreement (κ=0.063). This SNP was added to the 7-plex system (rs12913832 at HERC2, rs1545397 at OCA2, rs16891982 at SLC45A2, rs1426654 at SLC24A5, rs885479 at MC1R, rs6119471 at ASIP, and rs12203592 at IRF4). Further, the instruction guidelines on the interpretation of genotypes were changed to create a new 8-plex system. This was based on the analysis of an 803-sample training set of various populations. The newly developed 8-plex system can predict the eye colors brown, green, and blue, and skin colors light, not dark, and not light. It is superior to the 7-plex system with its additional ability to predict blue eye and light skin color. The 8-plex system was tested on an additional 212 samples, the test set. Analysis showed that the number of positive descriptions for eye colors as being brown, green, or blue increased significantly (P=6.98e-15, z-score: -7.786). The error rate for eye-color prediction was low, at approximately 5%, while the skin color prediction showed no error in the test set (1% in training set). We can conclude that the new 8-plex system for the prediction of eye and skin color substantially enhances its former version.
Mack, Maura; Kowalski, Elizabeth; Grahn, Robert; Bras, Dineli; Penedo, Maria Cecilia T.; Bellone, Rebecca
2017-01-01
A unique eye color, called tiger-eye, segregates in the Puerto Rican Paso Fino (PRPF) horse breed and is characterized by a bright yellow, amber, or orange iris. Pedigree analysis identified a simple autosomal recessive mode of inheritance for this trait. A genome-wide association study (GWAS) with 24 individuals identified a locus on ECA 1 reaching genome-wide significance (Pcorrected = 1.32 × 10−5). This ECA1 locus harbors the candidate gene, Solute Carrier Family 24 (Sodium/Potassium/Calcium Exchanger), Member 5 (SLC24A5), with known roles in pigmentation in humans, mice, and zebrafish. Humans with compound heterozygous mutations in SLC24A5 have oculocutaneous albinism (OCA) type 6 (OCA6), which is characterized by dilute skin, hair, and eye pigmentation, as well as ocular anomalies. Twenty tiger-eye horses were homozygous for a nonsynonymous mutation in exon 2 (p.Phe91Tyr) of SLC24A5 (called here Tiger-eye 1), which is predicted to be deleterious to protein function. Additionally, eight of the remaining 12 tiger-eye horses heterozygous for the p.Phe91Tyr variant were also heterozygous for a 628 bp deletion encompassing all of exon 7 of SLC24A5 (c.875-340_1081+82del), which we will call here the Tiger-eye 2 allele. None of the 122 brown-eyed horses were homozygous for either tiger-eye-associated allele or were compound heterozygotes. Further, neither variant was detected in 196 horses from four related breeds not known to have the tiger-eye phenotype. Here, we propose that two mutations in SLC24A5 affect iris pigmentation in tiger-eye PRPF horses. Further, unlike OCA6 in humans, the Tiger-eye 1 mutation in its homozygous state or as a compound heterozygote (Tiger-eye 1/Tiger-eye 2) does not appear to cause ocular anomalies or a change in coat color in the PRPF horse. PMID:28655738
A Single-Channel EOG-Based Speller.
He, Shenghong; Li, Yuanqing
2017-11-01
Electrooculography (EOG) signals, which can be used to infer the intentions of a user based on eye movements, are widely used in human-computer interface (HCI) systems. Most existing EOG-based HCI systems incorporate a limited number of commands because they generally associate different commands with a few different types of eye movements, such as looking up, down, left, or right. This paper presents a novel single-channel EOG-based HCI that allows users to spell asynchronously by only blinking. Forty buttons corresponding to 40 characters displayed to the user via a graphical user interface are intensified in a random order. To select a button, the user must blink his/her eyes in synchrony as the target button is flashed. Two data processing procedures, specifically support vector machine (SVM) classification and waveform detection, are combined to detect eye blinks. During detection, we simultaneously feed the feature vectors extracted from the ongoing EOG signal into the SVM classification and waveform detection modules. Decisions are made based on the results of the SVM classification and waveform detection. Three online experiments were conducted with eight healthy subjects. We achieved an average accuracy of 94.4% and a response time of 4.14 s for selecting a character in synchronous mode, as well as an average accuracy of 93.43% and a false positive rate of 0.03/min in the idle state in asynchronous mode. The experimental results, therefore, demonstrated the effectiveness of this single-channel EOG-based speller.
Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera
NASA Astrophysics Data System (ADS)
Liu, Rui-Xue; Zheng, Xian-Liang; Li, Da-Yu; Xia, Ming-Liang; Hu, Li-Fa; Cao, Zhao-Liang; Mu, Quan-Quan; Xuan, Li
2014-09-01
With the help of adaptive optics (AO) technology, cellular level imaging of living human retina can be achieved. Aiming to reduce distressing feelings and to avoid potential drug induced diseases, we attempted to image retina with dilated pupil and froze accommodation without drugs. An optimized liquid crystal adaptive optics camera was adopted for retinal imaging. A novel eye stared system was used for stimulating accommodation and fixating imaging area. Illumination sources and imaging camera kept linkage for focusing and imaging different layers. Four subjects with diverse degree of myopia were imaged. Based on the optical properties of the human eye, the eye stared system reduced the defocus to less than the typical ocular depth of focus. In this way, the illumination light can be projected on certain retina layer precisely. Since that the defocus had been compensated by the eye stared system, the adopted 512 × 512 liquid crystal spatial light modulator (LC-SLM) corrector provided the crucial spatial fidelity to fully compensate high-order aberrations. The Strehl ratio of a subject with -8 diopter myopia was improved to 0.78, which was nearly close to diffraction-limited imaging. By finely adjusting the axial displacement of illumination sources and imaging camera, cone photoreceptors, blood vessels and nerve fiber layer were clearly imaged successfully.
Defining the proteome of human iris, ciliary body, retinal pigment epithelium, and choroid.
Zhang, Pingbo; Kirby, David; Dufresne, Craig; Chen, Yan; Turner, Randi; Ferri, Sara; Edward, Deepak P; Van Eyk, Jennifer E; Semba, Richard D
2016-04-01
The iris is a fine structure that controls the amount of light that enters the eye. The ciliary body controls the shape of the lens and produces aqueous humor. The retinal pigment epithelium and choroid (RPE/choroid) are essential in supporting the retina and absorbing light energy that enters the eye. Proteins were extracted from iris, ciliary body, and RPE/choroid tissues of eyes from five individuals and fractionated using SDS-PAGE. After in-gel digestion, peptides were analyzed using LC-MS/MS on an Orbitrap Elite mass spectrometer. In iris, ciliary body, and RPE/choroid, we identified 2959, 2867, and 2755 nonredundant proteins with peptide and protein false-positive rates of <0.1% and <1%, respectively. Forty-three unambiguous protein isoforms were identified in iris, ciliary body, and RPE/choroid. Four "missing proteins" were identified in ciliary body based on ≥2 proteotypic peptides. The mass spectrometric proteome database of the human iris, ciliary body, and RPE/choroid may serve as a valuable resource for future investigations of the eye in health and disease. The MS proteomics data have been deposited to the ProteomeXchange Consortium via the PRIDE partner repository with the dataset identifiers PXD001424 and PXD002194. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng
2012-07-01
A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.
Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min
2011-02-01
Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.
75 FR 48976 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-12
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Epi R01s, Data Analysis... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...
Material Properties of the Posterior Human Sclera☆
Grytz, Rafael; Fazio, Massimo A.; Girard, Michael J.A.; Libertiaux, Vincent; Bruno, Luigi; Gardiner, Stuart; Girkin, Christopher A.; Downs, J. Crawford
2013-01-01
To characterize the material properties of posterior and peripapillary sclera from human donors, and to investigate the macro- and micro-scale strains as potential control mechanisms governing mechanical homeostasis. Posterior scleral shells from 9 human donors aged 57–90 years were subjected to IOP elevations from 5 to 45 mmHg and the resulting full-field displacements were recorded using laser speckle interferometry. Eye-specific finite element models were generated based on experimentally measured scleral shell surface geometry and thickness. Inverse numerical analyses were performed to identify material parameters for each eye by matching experimental deformation measurements to model predictions using a microstructure-based constitutive formulation that incorporates the crimp response and anisotropic architecture of scleral collagen fibrils. The material property fitting produced models that fit both the overall and local deformation responses of posterior scleral shells very well. The nonlinear stiffening of the sclera with increasing IOP was well reproduced by the uncrimping of scleral collagen fibrils, and a circumferentially-aligned ring of collagen fibrils around the scleral canal was predicted in all eyes. Macroscopic in-plane strains were significantly higher in peripapillary region then in the mid-periphery. In contrast, the meso- and micro-scale strains at the collagen network and collagen fibril level were not significantly different between regions. The elastic response of the posterior human sclera can be characterized by the anisotropic architecture and crimp response of scleral collagen fibrils. The similar collagen fibril strains in the peripapillary and mid-peripheral regions support the notion that the scleral collagen architecture including the circumpapillary ring of collagen fibrils evolved to establish optimal load bearing conditions at the collagen fibril level. PMID:23684352
75 FR 16818 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Training Grants.... [[Page 16819
Virtual view image synthesis for eye-contact in TV conversation system
NASA Astrophysics Data System (ADS)
Murayama, Daisuke; Kimura, Keiichi; Hosaka, Tadaaki; Hamamoto, Takayuki; Shibuhisa, Nao; Tanaka, Seiichi; Sato, Shunichi; Saito, Sakae
2010-02-01
Eye-contact plays an important role for human communications in the sense that it can convey unspoken information. However, it is highly difficult to realize eye-contact in teleconferencing systems because of camera configurations. Conventional methods to overcome this difficulty mainly resorted to space-consuming optical devices such as half mirrors. In this paper, we propose an alternative approach to achieve eye-contact by techniques of arbitrary view image synthesis. In our method, multiple images captured by real cameras are converted to the virtual viewpoint (the center of the display) by homography, and evaluation of matching errors among these projected images provides the depth map and the virtual image. Furthermore, we also propose a simpler version of this method by using a single camera to save the computational costs, in which the only one real image is transformed to the virtual viewpoint based on the hypothesis that the subject is located at a predetermined distance. In this simple implementation, eye regions are separately generated by comparison with pre-captured frontal face images. Experimental results of both the methods show that the synthesized virtual images enable the eye-contact favorably.
Corsi-Cabrera, María; Velasco, Francisco; Del Río-Portilla, Yolanda; Armony, Jorge L; Trejo-Martínez, David; Guevara, Miguel A; Velasco, Ana L
2016-10-01
The amygdaloid complex plays a crucial role in processing emotional signals and in the formation of emotional memories. Neuroimaging studies have shown human amygdala activation during rapid eye movement sleep (REM). Stereotactically implanted electrodes for presurgical evaluation in epileptic patients provide a unique opportunity to directly record amygdala activity. The present study analysed amygdala activity associated with REM sleep eye movements on the millisecond scale. We propose that phasic activation associated with rapid eye movements may provide the amygdala with endogenous excitation during REM sleep. Standard polysomnography and stereo-electroencephalograph (SEEG) were recorded simultaneously during spontaneous sleep in the left amygdala of four patients. Time-frequency analysis and absolute power of gamma activity were obtained for 250 ms time windows preceding and following eye movement onset in REM sleep, and in spontaneous waking eye movements in the dark. Absolute power of the 44-48 Hz band increased significantly during the 250 ms time window after REM sleep rapid eye movements onset, but not during waking eye movements. Transient activation of the amygdala provides physiological support for the proposed participation of the amygdala in emotional expression, in the emotional content of dreams and for the reactivation and consolidation of emotional memories during REM sleep, as well as for next-day emotional regulation, and its possible role in the bidirectional interaction between REM sleep and such sleep disorders as nightmares, anxiety and post-traumatic sleep disorder. These results provide unique, direct evidence of increased activation of the human amygdala time-locked to REM sleep rapid eye movements. © 2016 European Sleep Research Society.
Human Commercial Models' Eye Colour Shows Negative Frequency-Dependent Selection.
Forti, Isabela Rodrigues Nogueira; Young, Robert John
2016-01-01
In this study we investigated the eye colour of human commercial models registered in the UK (400 female and 400 male) and Brazil (400 female and 400 male) to test the hypothesis that model eye colour frequency was the result of negative frequency-dependent selection. The eye colours of the models were classified as: blue, brown or intermediate. Chi-square analyses of data for countries separated by sex showed that in the United Kingdom brown eyes and intermediate colours were significantly more frequent than expected in comparison to the general United Kingdom population (P<0.001). In Brazil, the most frequent eye colour brown was significantly less frequent than expected in comparison to the general Brazilian population. These results support the hypothesis that model eye colour is the result of negative frequency-dependent selection. This could be the result of people using eye colour as a marker of genetic diversity and finding rarer eye colours more attractive because of the potential advantage more genetically diverse offspring that could result from such a choice. Eye colour may be important because in comparison to many other physical traits (e.g., hair colour) it is hard to modify, hide or disguise, and it is highly polymorphic.
Dynamic light scattering in ophthalmology: results of in vitro and in vivo experiments.
Fankhauser, Franz
2006-01-01
To calibrate new dynamic light scattering (DLS) devices in defined solutions and post mortem porcine and human eyes. To examine all segments of the eye and to become familiar with the usage of the technique in living subjects. METHODS, DESIGN: Three new DLS devices for the usage in patients were developed. Mono-disperse solutions, poly-disperse solutions, gels, post mortem porcine and human eyes as well as healthy volunteers were studied. The detected signals were inverted into autocorrelation functions. We constructed three DLS devices appropriate for in vitro as well as in vivo examinations. In mono disperse solution precise disintegration rates could be calculated. In poly-disperse solutions, in gel and in the vitreous the results did not correlate with movements of individual particles but we could calculate characteristics of the complete scattering system. In vivo measurements demonstrated that DLS can be used in all human eye segments. DLS is a unique technique. With DLS the molecular composition of eye segments can be studied in living subjects. This can be used to understand the molecular basis of severe eye diseases. The presented data demonstrate that DLS delivers reproducible data from all eye segments. It is possible to study the molecular structures of eye segments in living subjects. The developed devices were proved successfully in vitro as well as in vivo. Limitations are the low specificity of DLS and its sensitivity to background noise. Now clinical studies are necessary to demonstrate potential diagnostic benefits of DLS in specific eye diseases.
Genes relacionados con microftalmia y anoftalmia hereditarias.
Matías-Pérez, Diana; García-Montalvo, Iván Antonio; Zenteno, Juan Carlos
2017-01-01
Congenital eye malformations are the second most common cause of childhood blindness and are originated by disruption of the normal process of eye development during embryonic stage. Their etiology is variable, although monogenic causes are of great importance as they have a high risk of familial recurrence. Included among the most severe congenital eye abnormalities are microphthalmia, defined by an abnormally small eye, and anophthalmia, characterized by congenital absence of ocular structures. The currrent knowledge of the genes involved in human microphthalmia and anophthalmia in humans is revised in this work. Copyright: © 2017 SecretarÍa de Salud.
Yeater, Deirdre B; Hill, Heather M; Baus, Natalie; Farnell, Heather; Kuczaj, Stan A
2014-11-01
Lateralization of cognitive processes and motor functions has been demonstrated in a number of species, including humans, elephants, and cetaceans. For example, bottlenose dolphins (Tursiops truncatus) have exhibited preferential eye use during a variety of cognitive tasks. The present study investigated the possibility of visual lateralization in 12 belugas (Delphinapterus leucas) and six Pacific white-sided dolphins (Lagenorhynchus obliquidens) located at two separate marine mammal facilities. During free swim periods, the belugas and Pacific white-sided dolphins were presented a familiar human, an unfamiliar human, or no human during 10-15 min sessions. Session videos were coded for gaze duration, eye presentation at approach, and eye preference while viewing each stimulus. Although we did not find any clear group level lateralization, we found individual left eye lateralized preferences related to social stimuli for most belugas and some Pacific white-sided dolphins. Differences in gaze durations were also observed. The majority of individual belugas had longer gaze durations for unfamiliar rather than familiar stimuli. These results suggest that lateralization occurs during visual processing of human stimuli in belugas and Pacific white-sided dolphins and that these species can distinguish between familiar and unfamiliar humans.
Gertz, Hanna; Hilger, Maximilian; Hegele, Mathias; Fiehler, Katja
2016-09-01
Previous studies have shown that beliefs about the human origin of a stimulus are capable of modulating the coupling of perception and action. Such beliefs can be based on top-down recognition of the identity of an actor or bottom-up observation of the behavior of the stimulus. Instructed human agency has been shown to lead to superior tracking performance of a moving dot as compared to instructed computer agency, especially when the dot followed a biological velocity profile and thus matched the predicted movement, whereas a violation of instructed human agency by a nonbiological dot motion impaired oculomotor tracking (Zwickel et al., 2012). This suggests that the instructed agency biases the selection of predictive models on the movement trajectory of the dot motion. The aim of the present fMRI study was to examine the neural correlates of top-down and bottom-up modulations of perception-action couplings by manipulating the instructed agency (human action vs. computer-generated action) and the observable behavior of the stimulus (biological vs. nonbiological velocity profile). To this end, participants performed an oculomotor tracking task in an MRI environment. Oculomotor tracking activated areas of the eye movement network. A right-hemisphere occipito-temporal cluster comprising the motion-sensitive area V5 showed a preference for the biological as compared to the nonbiological velocity profile. Importantly, a mismatch between instructed human agency and a nonbiological velocity profile primarily activated medial-frontal areas comprising the frontal pole, the paracingulate gyrus, and the anterior cingulate gyrus, as well as the cerebellum and the supplementary eye field as part of the eye movement network. This mismatch effect was specific to the instructed human agency and did not occur in conditions with a mismatch between instructed computer agency and a biological velocity profile. Our results support the hypothesis that humans activate a specific predictive model for biological movements based on their own motor expertise. A violation of this predictive model causes costs as the movement needs to be corrected in accordance with incoming (nonbiological) sensory information. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Science Teacher, 2005
2005-01-01
Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…
21 CFR 886.3320 - Eye sphere implant.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Eye sphere implant. 886.3320 Section 886.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3320 Eye sphere implant. (a) Identification. An eye...
77 FR 12318 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Anterior Eye Disease. Date: March 19, 2012. Time: 1 p.m. to 2:30 p.m. Agenda: To review and...
75 FR 13769 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; National Eye Institute SBIR Special Emphasis Panel. Date: April 9, 2010. Time: 8:30 a.m. to 5 p.m. Agenda...
75 FR 20853 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-21
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Immunosuppression for Eye Diseases. Date: April 20, 2010. Time: 3 p.m. to 4 p.m. Agenda: To review and evaluate...
21 CFR 886.3320 - Eye sphere implant.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye sphere implant. 886.3320 Section 886.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3320 Eye sphere implant. (a) Identification. An eye...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...
Sheth-Shah, Radhika; Vernon, Amanda J; Seetharaman, Shankar; Neale, Michael H; Daniels, Julie T
2016-04-01
In the past decade, stem cell therapy has been increasingly employed for the treatment of various diseases. Subsequently, there has been a great interest in the manufacture of stem cells under good manufacturing practice, which is required by law for their use in humans. The cells for sight Stem Cell Therapy Research Unit, based at UCL Institute of Ophthalmology, delivers somatic cell-based and tissue-engineered therapies to patients suffering from blinding eye diseases at Moorfields Eye Hospital (London, UK). The following article is based on our experience in the conception, design, construction, validation and manufacturing within a good manufacturing practice manufacturing facility based in the UK. As such the regulations can be extrapolated to the 28 members stated within the EU. However, the principles may have a broad relevance outside the EU.
An eye model for uncalibrated eye gaze estimation under variable head pose
NASA Astrophysics Data System (ADS)
Hnatow, Justin; Savakis, Andreas
2007-04-01
Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.
Eye Movements in Darkness Modulate Self-Motion Perception.
Clemens, Ivar Adrianus H; Selen, Luc P J; Pomante, Antonella; MacNeilage, Paul R; Medendorp, W Pieter
2017-01-01
During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first ( n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment ( n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation.
Eye Movements in Darkness Modulate Self-Motion Perception
Pomante, Antonella
2017-01-01
Abstract During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first (n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment (n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation. PMID:28144623
Comparison of two scanning instruments to measure peripheral refraction in the human eye.
Jaeken, Bart; Tabernero, Juan; Schaeffel, Frank; Artal, Pablo
2012-03-01
To better understand how peripheral refraction affects development of myopia in humans, specialized instruments are fundamental for precise and rapid measurements of refraction over the visual field. We compare here two prototype instruments that measure in a few seconds the peripheral refraction in the eye with high angular resolution over a range of about ±45 deg. One instrument is based on the continuous recording of Hartmann-Shack (HS) images (HS scanner) and the other is based on the photorefraction (PR) principle (PR scanner). On average, good correlations were found between the refraction results provided by the two devices, although it varied across subjects. A detailed statistical analysis of the differences between both instruments was performed based on measurements in 35 young subjects. Both instruments have advantages and disadvantages. The HS scanner also provides the high-order aberration data, while the PR scanner is more compact and has a lower cost. Both instruments are current prototypes, and further optimization is possible to make them even more suitable tools for future visual optics and myopia research and also for different ophthalmic applications.
Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques
2010-03-01
The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Visidep (TM): A Three-Dimensional Imaging System For The Unaided Eye
NASA Astrophysics Data System (ADS)
McLaurin, A. Porter; Jones, Edwin R.; Cathey, LeConte
1984-05-01
The VISIDEP process for creating images in three dimensions on flat screens is suitable for photographic, electrographic and computer generated imaging systems. Procedures for generating these images vary from medium to medium due to the specific requirements of each technology. Imaging requirements for photographic and electrographic media are more directly tied to the hardware than are computer based systems. Applications of these technologies are not limited to entertainment, but have implications for training, interactive computer/video systems, medical imaging, and inspection equipment. Through minor modification the system can provide three-dimensional images with accurately measureable relationships for robotics and adds this factor for future developments in artificial intelligence. In almost any area requiring image analysis or critical review, VISIDEP provides the added advantage of three-dimensionality. All of this is readily accomplished without aids to the human eye. The system can be viewed in full color, false-color infra-red, and monochromatic modalities from any angle and is also viewable with a single eye. Thus, the potential of application for this developing system is extensive and covers the broad spectrum of human endeavor from entertainment to scientific study.
Olsen, Timothy W; Liao, Albert; Robinson, Hershonna S; Palejwala, Neal V; Sprehe, Nicholas
2017-10-01
To refine the Minnesota Grading System (MGS) using definitions from the Age-Related Eye Disease Studies (AREDS) into a nine-step grading scale (MGS-9). A nine-step grading scale descriptive analysis using three key phenotypic features (total drusen area, increased, and decreased pigmentation) of human eyebank eyes that were graded according to definitions from the AREDS criteria in order to harmonize studies of disease progression for research involving human tissue. From 2005 through February 2017, we have analyzed 1159 human eyes, procured from two eyebanks. Each macula was imaged using high-resolution, stereoscopic color fundus photography with both direct- and transillumination. Fundus images were digitally overlaid with a grading template and triangulated for foveal centration. We documented and stratified risk for each globe by applying the AREDS nine-step grading scale to the key clinical features from the MGS-9. We found a good distribution within the MGS categories (1-9) with few level eight globes. Eyes were processed within 12.1 ± 6.3, hours from the time of death through imaging, dissection, and freezing or fixation. Applying the MGS-9 to 331 pairs (662 eyes were simultaneously graded), 84% were within one-grading step and 93% within two steps of the fellow eye. We also document reticular pseudodrusen, basal laminar drusen, and pattern dystrophy. The MGS nine-step grading scale enables researchers using human tissue to refine the risk assessment of donor tissue. This analysis will harmonize results among researchers when grading human tissue using MGS criteria. Most importantly, the MGS-9 links directly to the known risk for progression from the AREDS.
Effects of light on brain and behavior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brainard, G.C.
1994-12-31
It is obvious that light entering the eye permits the sensory capacity of vision. The human species is highly dependent on visual perception of the environment and consequently, the scientific study of vision and visual mechanisms is a centuries old endeavor. Relatively new discoveries are now leading to an expanded understanding of the role of light entering the eye - in addition to supporting vision, light has various nonvisual biological effects. Over the past thirty years, animal studies have shown that environmental light is the primary stimulus for regulating circadian rhythms, seasonal cycles, and neuroendocrine responses. As with all photobiologicalmore » phenomena, the wavelength, intensity, timing and duration of a light stimulus is important in determining its regulatory influence on the circadian and neuroendocrine systems. Initially, the effects of light on rhythms and hormones were observed only in sub-human species. Research over the past decade, however, has confirmed that light entering the eyes of humans is a potent stimulus for controlling physiological rhythms. The aim of this paper is to examine three specific nonvisual responses in humans which are mediated by light entering the eye: light-induced melatonin suppression, light therapy for winter depression, and enhancement of nighttime performance. This will serve as a brief introduction to the growing database which demonstrates how light stimuli can influence physiology, mood and behavior in humans. Such information greatly expands our understanding of the human eye and will ultimately change our use of light in the human environment.« less
Effects of light on brain and behavior
NASA Technical Reports Server (NTRS)
Brainard, George C.
1994-01-01
It is obvious that light entering the eye permits the sensory capacity of vision. The human species is highly dependent on visual perception of the environment and consequently, the scientific study of vision and visual mechanisms is a centuries old endeavor. Relatively new discoveries are now leading to an expanded understanding of the role of light entering the eye in addition to supporting vision, light has various nonvisual biological effects. Over the past thirty years, animal studies have shown that environmental light is the primary stimulus for regulating circadian rhythms, seasonal cycles, and neuroendocrine responses. As with all photobiological phenomena, the wavelength, intensity, timing and duration of a light stimulus is important in determining its regulatory influence on the circadian and neuroendocrine systems. Initially, the effects of light on rhythms and hormones were observed only in sub-human species. Research over the past decade, however, has confirmed that light entering the eyes of humans is a potent stimulus for controlling physiological rhythms. The aim of this paper is to examine three specific nonvisual responses in humans which are mediated by light entering the eye: light-induced melatonin suppression, light therapy for winter depression, and enhancement of nighttime performance. This will serve as a brief introduction to the growing database which demonstrates how light stimuli can influence physiology, mood and behavior in humans. Such information greatly expands our understanding of the human eye and will ultimately change our use of light in the human environment.
A workforce in crisis: a case study to expand allied ophthalmic personnel.
Astle, William; Simms, Craig; Anderson, Lynn
2016-08-01
To examine how the development of allied ophthalmic personnel training programs affects human resource capacity. Using a qualitative case study method conducted at a single Ontario institution, this article describes 6 years of establishing a 2-tiered allied ophthalmic personnel training program. The Kingston Ophthalmic Training Centre participated in the study with 8 leadership and program graduate interviews. To assess regional eye health workforce needs, a case study and iterative process used triangulations of the literature, case study, and qualitative interviews with stakeholders. This research was used to develop a model for establishing allied ophthalmic personnel training programs that would result in expanding human resource capacity. Current human resource capacity development and deployment is inadequate to provide the needed eye care services in Canada. A competency-based curriculum and accreditation model as the platform to develop formal academic training programs is essential. Access to quality eye care and patient services can be met by task-shifting from ophthalmologists to appropriately trained allied ophthalmic personnel. Establishing formal training programs is one important strategy to supplying a well-skilled, trained, and qualified ophthalmic workforce. This initiative meets the criteria required for quality, relevance, equity, and cost-effectiveness to meet the future demands for ophthalmic patient care. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Sensing Passive Eye Response to Impact Induced Head Acceleration Using MEMS IMUs.
Meng, Yuan; Bottenfield, Brent; Bolding, Mark; Liu, Lei; Adams, Mark L
2018-02-01
The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.
Head Worn Display System for Equivalent Visual Operations
NASA Technical Reports Server (NTRS)
Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob
2009-01-01
Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.
Secchi disk observation with spectral-selective glasses in blue and green waters.
Lee, Zhongping; Shang, Shaoling; Lin, Gong; Liu, Tongtong; Liu, Yangyang; Du, Keping; Luis, Kelly
2017-08-21
Radiative transfer modeling of Secchi disk observations has historically been based on conjugated signals of eye response and radiance, where water's attenuation in the entire visible band is included in the attenuation when deciding the Secchi disk depth in water. Aas et al. [Ocean Sci.10(2), 177 (2014)Remote Sens. Environ.169, 139 (2015)] hypothesized that it is actually the attenuation in water's transparent window that matters to the observation of a Secchi disk in water. To test this hypothesis, observations of Secchi disks in blue and green waters were conducted via naked eyes, blue-pass glasses, and green-pass glasses. Measurement results indicate that for blue waters, the observed Secchi depths via naked eyes match the depths obtained with blue-pass glasses and much deeper than the depths with green-pass glasses, although the green-pass glasses match the highest response of human eyes. These observations experimentally support the hypothesis that our eye-brain system uses the contrast information in the transparent window to make a judgement decision regarding sighting a Secchi disk in water.
The Importance of Postural Cues for Determining Eye Height in Immersive Virtual Reality
Leyrer, Markus; Linkenauger, Sally A.; Bülthoff, Heinrich H.; Mohler, Betty J.
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height. PMID:25993274
The importance of postural cues for determining eye height in immersive virtual reality.
Leyrer, Markus; Linkenauger, Sally A; Bülthoff, Heinrich H; Mohler, Betty J
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height.
Denion, Eric; Hitier, Martin; Levieil, Eric; Mouriaux, Frédéric
2015-01-01
While convergent, the human orbit differs from that of non-human apes in that its lateral orbital margin is significantly more rearward. This rearward position does not obstruct the additional visual field gained through eye motion. This additional visual field is therefore considered to be wider in humans than in non-human apes. A mathematical model was designed to quantify this difference. The mathematical model is based on published computed tomography data in the human neuro-ocular plane (NOP) and on additional anatomical data from 100 human skulls and 120 non-human ape skulls (30 gibbons; 30 chimpanzees / bonobos; 30 orangutans; 30 gorillas). It is used to calculate temporal visual field eccentricity values in the NOP first in the primary position of gaze then for any eyeball rotation value in abduction up to 45° and any lateral orbital margin position between 85° and 115° relative to the sagittal plane. By varying the lateral orbital margin position, the human orbit can be made “non-human ape-like”. In the Pan-like orbit, the orbital margin position (98.7°) was closest to the human orbit (107.1°). This modest 8.4° difference resulted in a large 21.1° difference in maximum lateral visual field eccentricity with eyeball abduction (Pan-like: 115°; human: 136.1°). PMID:26190625
Digital Quantification of Human Eye Color Highlights Genetic Association of Three New Loci
Liu, Fan; Wollstein, Andreas; Hysi, Pirro G.; Ankra-Badu, Georgina A.; Spector, Timothy D.; Park, Daniel; Zhu, Gu; Larsson, Mats; Duffy, David L.; Montgomery, Grant W.; Mackey, David A.; Walsh, Susan; Lao, Oscar; Hofman, Albert; Rivadeneira, Fernando; Vingerling, Johannes R.; Uitterlinden, André G.; Martin, Nicholas G.; Hammond, Christopher J.; Kayser, Manfred
2010-01-01
Previous studies have successfully identified genetic variants in several genes associated with human iris (eye) color; however, they all used simplified categorical trait information. Here, we quantified continuous eye color variation into hue and saturation values using high-resolution digital full-eye photographs and conducted a genome-wide association study on 5,951 Dutch Europeans from the Rotterdam Study. Three new regions, 1q42.3, 17q25.3, and 21q22.13, were highlighted meeting the criterion for genome-wide statistically significant association. The latter two loci were replicated in 2,261 individuals from the UK and in 1,282 from Australia. The LYST gene at 1q42.3 and the DSCR9 gene at 21q22.13 serve as promising functional candidates. A model for predicting quantitative eye colors explained over 50% of trait variance in the Rotterdam Study. Over all our data exemplify that fine phenotyping is a useful strategy for finding genes involved in human complex traits. PMID:20463881
Huang, Qian; Xu, Ping; Xia, Xin; Hu, Hong-hui; Wang, Feng; Li, Hui-ming
2006-02-01
To investigate the efficacy of subretinal transplantation of CNTF gene transfected fibroblasts for preventing photoreceptor degeneration in RCS. The human fetal lung fibroblasts with high level expression of CNTF were established by liposome mediated gene transfer and MTX selection. A 5 microl of cell suspension, containing 1 x 10(5) cells, was injected through pars plana of ciliary body into the subretinal space of the right eye at postnatal 4-5 weeks, the left eye was left without injection or injected with PBS as controls. The both eyes were enucleated for histopathological examinations at 2, 4, 6, 8, 10, 12 and 15 weeks following transplantation. The level of CNTF protein (91,046.15 pg/ml) expressed in the transfected cells was determined by sandwich enzyme-linked immunosorbent assay (ELISA). The four of seven eyes examined by light microscopy and the ten of 14 eyes examined by electro microscopy showed rescue effect. The prolonged photoreceptor survival, reduction of apoptotic cells and debris were observed in transplanted eyes in comparison with untreated or sham-injected eyes. This study provides the first indication that transplanted human fibroblasts with high level expression of CNTF are able to rescue photoreceptor degeneration in RCS dystrophic rat retina.
Amylin competes for binding sites of CGRP in the chamber angle and uvea of monkey, cat, and pig eye.
Alajuuma, Päivi; Oksala, Olli; Uusitalo, Hannu
2003-12-01
Calcitonin gene-related peptide (CGRP) binding sites have been identified previously in the eyes of monkey, cat, pig, and guinea pig. In this study, the ability of cat, human, and rat amylins to displace the binding of CGRP in the anterior part of the eye of monkey, cat, and pig was studied. The location and displacement of 125I-hCGRPalpha by amylins as concentrations of 1-1000 nM were studied in cryosections by autoradiography. In the monkey eye, cat and rat amylins were able to compete for the binding sites of CGRP in ciliary muscle and ciliary processes. In the cat eye, cat and human amylins clearly displaced CGRP binding from ciliary muscle, ciliary processes, iris, and chamber angle. Furthermore, rat amylin clearly displaced CGRP binding from ciliary muscle and ciliary processes. In the pig eye, cat, human, and rat amylins competed for the binding sites of CGRP in ciliary muscle, ciliary processes, iris, and limbal conjunctiva. Specific amylin receptors or the possible physiological role of amylin in the eye have not hitherto been reported. It seems, however, that amylin can bind to ocular CGRP receptors and thus probably plays a role in the regulation of the same functions as CGRP, (e.g., aqueous humor outflow).
GOM-Face: GKP, EOG, and EMG-based multimodal interface with application to humanoid robot control.
Nam, Yunjun; Koo, Bonkon; Cichocki, Andrzej; Choi, Seungjin
2014-02-01
We present a novel human-machine interface, called GOM-Face , and its application to humanoid robot control. The GOM-Face bases its interfacing on three electric potentials measured on the face: 1) glossokinetic potential (GKP), which involves the tongue movement; 2) electrooculogram (EOG), which involves the eye movement; 3) electromyogram, which involves the teeth clenching. Each potential has been individually used for assistive interfacing to provide persons with limb motor disabilities or even complete quadriplegia an alternative communication channel. However, to the best of our knowledge, GOM-Face is the first interface that exploits all these potentials together. We resolved the interference between GKP and EOG by extracting discriminative features from two covariance matrices: a tongue-movement-only data matrix and eye-movement-only data matrix. With the feature extraction method, GOM-Face can detect four kinds of horizontal tongue or eye movements with an accuracy of 86.7% within 2.77 s. We demonstrated the applicability of the GOM-Face to humanoid robot control: users were able to communicate with the robot by selecting from a predefined menu using the eye and tongue movements.
Modern Corneal Eye-Banking Using a Software-Based IT Management Solution.
Kern, C; Kortuem, K; Wertheimer, C; Nilmayer, O; Dirisamer, M; Priglinger, S; Mayer, W J
2018-01-01
Increasing government legislation and regulations in manufacturing have led to additional documentation regarding the pharmaceutical product requirements of corneal grafts in the European Union. The aim of this project was to develop a software within a hospital information system (HIS) to support the documentation process, to improve the management of the patient waiting list and to increase informational flow between the clinic and eye bank. After an analysis of the current documentation process, a new workflow and software were implemented in our electronic health record (EHR) system. The software takes over most of the documentation and reduces the time required for record keeping. It guarantees real-time tracing of all steps during human corneal tissue processing from the start of production until allocation during surgery and includes follow-up within the HIS. Moreover, listing of the patient for surgery as well as waiting list management takes place in the same system. The new software for corneal eye banking supports the whole process chain by taking over both most of the required documentation and the management of the transplant waiting list. It may provide a standardized IT-based solution for German eye banks working within the same HIS.
Song, Hong-Yan; Qiu, Bao-Feng; Liu, Chun; Zhu, Shun-Xing; Wang, Sheng-Cun; Miao, Jin; Jing, Jing; Shao, Yi-Xiang
2014-01-01
The clone library method using PCR amplification of the 16S ribosomal RNA (rRNA) gene was used to identify pathogens from corneal scrapings of C57BL/6-corneal opacity (B6-Co) mice with bacterial keratitis. All 10 samples from the eyes with bacterial keratitis showed positive PCR results. All 10 samples from the normal cornea showed negative PCR results. In all 10 PCR-positive samples, the predominant and second most predominant species accounted for 20.9 to 40.6% and 14.7 to 26.1%, respectively, of each clone library. The predominant species were Staphylococcus lentus, Pseudomonas aeruginosa, and Staphylococcus epidermidis. The microbiota analysis detected a diverse group of microbiota in the eyes of B6-Co mice with bacterial keratitis and showed that the causative pathogens could be determined based on percentages of bacterial species in the clone libraries. The bacterial species detected in this study were mostly in accordance with results of studies on clinical bacterial keratitis in human eyes. Based on the results of our previous studies and this study, the B6-Co mouse should be considered a favorable model for studying bacterial keratitis. PMID:25312507
Human Eye Development Is Characterized by Coordinated Expression of Fibrillin Isoforms
Hubmacher, Dirk; Reinhardt, Dieter P.; Plesec, Thomas; Schenke-Layland, Katja; Apte, Suneel S.
2014-01-01
Purpose. Mutations in human fibrillin-1 and -2, which are major constituents of tissue microfibrils, can affect multiple ocular components, including the ciliary zonule, lens, drainage apparatus, cornea, and retina. However, the expression pattern of the three human fibrillins and an integral microfibrillar component, MAGP1, during human eye development is not known. Methods. We analyzed sections from human eyes at gestational weeks (GWs) 6, 8, and 11 and at 1 and 3 years of age with antibodies specific for each human fibrillin isoform or MAGP1, using immunofluorescence microscopy. Results. During embryonic development, each fibrillin isoform was detected in vascular structures bridging the ciliary body and the developing lens, hyaloid vasculature, and retina. In addition, they were present in the developing corneal basement membranes and lens capsule. MAGP1 codistributed with the fibrillin isoforms. In contrast, the juvenile zonule was composed of fibrillin-1 microfibrils containing MAGP1, but fibrillin-2 was absent and fibrillin-3 was only sparsely detected. Conclusions. Fibrillin-1, -2, and, unique to humans, fibrillin-3 are found in various ocular structures during human embryonic eye development, whereas fibrillin-1 dominates the postnatal zonule. We speculate that vasculature spanning the ciliary body and lens, which elaborates fibrillin-2 and -3, may provide an initial scaffold for fibrillin assembly and zonule formation. PMID:25406291
Effects of phencyclidine, secobarbital and diazepam on eye tracking in rhesus monkeys.
Ando, K; Johanson, C E; Levy, D L; Yasillo, N J; Holzman, P S; Schuster, C R
1983-01-01
Rhesus monkeys were trained to track a moving disk using a procedure in which responses on a lever were reinforced with water delivery only when the disk, oscillating in a horizontal plane on a screen at a frequency of 0.4 Hz in a visual angle of 20 degrees, dimmed for a brief period. Pursuit eye movements were recorded by electrooculography (EOG). IM phencyclidine, secobarbital, and diazepam injections decreased the number of reinforced lever presses in a dose-related manner. Both secobarbital and diazepam produced episodic jerky-pursuit eye movements, while phencyclidine had no consistent effects on eye movements. Lever pressing was disrupted at doses which had little effect on the quality of smooth-pursuit eye movements in some monkeys. This separation was particularly pronounced with diazepam. The similarities of the drug effects on smooth-pursuit eye movements between the present study and human studies indicate that the present method using rhesus monkeys may be useful for predicting drug effects on eye tracking and oculomotor function in humans.
Simulation of Ametropic Human Eyes
NASA Astrophysics Data System (ADS)
Tan, Bo; Chen, Ying-Ling; Lewis, James W. L.
2004-11-01
The computational simulation of the performance of human eyes is complex because the optical parameters of the eye depend on many factors, including age, gender, race, refractive status (accommodation and near- or far-sightedness). This task is made more difficult by the inadequacy of the population statistical characteristics of these parameters. Previously we simulated ametropic (near- or far-sighted) eyes using three independent variables: the axial length of the eye, the corneal surface curvature, and the intraocular refractive index gradient. The prescription for the correction of an ametropic eye is determined by its second-order coefficients of the wavefront aberrations. These corrections are typically achieved using contact lens, spectacle lens, or laser surgery (LASIK). However, the higher order aberrations, which are not corrected and are likely complicated or enhanced by the lower-order correction, could be important for visual performance in a darkened environment. In this paper, we investigate the higher order wavefront aberrations of synthetic ametropic eyes and compare results with measured data published in the past decade. The behavior of three types of ametropes is discussed.
The Effectiveness of Gaze-Contingent Control in Computer Games.
Orlov, Paul A; Apraksin, Nikolay
2015-01-01
Eye-tracking technology and gaze-contingent control in human-computer interaction have become an objective reality. This article reports on a series of eye-tracking experiments, in which we concentrated on one aspect of gaze-contingent interaction: Its effectiveness compared with mouse-based control in a computer strategy game. We propose a measure for evaluating the effectiveness of interaction based on "the time of recognition" the game unit. In this article, we use this measure to compare gaze- and mouse-contingent systems, and we present the analysis of the differences as a function of the number of game units. Our results indicate that performance of gaze-contingent interaction is typically higher than mouse manipulation in a visual searching task. When tested on 60 subjects, the results showed that the effectiveness of gaze-contingent systems over 1.5 times higher. In addition, we obtained that eye behavior stays quite stabile with or without mouse interaction. © The Author(s) 2015.
Comprehensive Oculomotor Behavioral Response Assessment (COBRA)
NASA Technical Reports Server (NTRS)
Stone, Leland S. (Inventor); Liston, Dorion B. (Inventor)
2017-01-01
An eye movement-based methodology and assessment tool may be used to quantify many aspects of human dynamic visual processing using a relatively simple and short oculomotor task, noninvasive video-based eye tracking, and validated oculometric analysis techniques. By examining the eye movement responses to a task including a radially-organized appropriately randomized sequence of Rashbass-like step-ramp pursuit-tracking trials, distinct performance measurements may be generated that may be associated with, for example, pursuit initiation (e.g., latency and open-loop pursuit acceleration), steady-state tracking (e.g., gain, catch-up saccade amplitude, and the proportion of the steady-state response consisting of smooth movement), direction tuning (e.g., oblique effect amplitude, horizontal-vertical asymmetry, and direction noise), and speed tuning (e.g., speed responsiveness and noise). This quantitative approach may provide fast and results (e.g., a multi-dimensional set of oculometrics and a single scalar impairment index) that can be interpreted by one without a high degree of scientific sophistication or extensive training.
Alternatives to eye bank native tissue for corneal stromal replacement.
Brunette, Isabelle; Roberts, Cynthia J; Vidal, François; Harissi-Dagher, Mona; Lachaine, Jean; Sheardown, Heather; Durr, Georges M; Proulx, Stéphanie; Griffith, May
2017-07-01
Corneal blindness is a major cause of blindness in the world and corneal transplantation is the only widely accepted treatment to restore sight in these eyes. However, it is becoming increasingly difficult for eye banks to meet the increasing demand for transplantable tissue, which is in part due to population aging. Donor tissue shortage is therefore a growing concern globally and there is a need for alternatives to human donor corneas. Biosynthetic corneal substitutes offer several significant advantages over native corneas: Large-scale production offers a powerful potential solution to the severe shortage of human donor corneas worldwide; Good manufacturing practices ensure sterility and quality control; Acellular corneal substitutes circumvent immune rejection induced by allogeneic cells; Optical and biomechanical properties of the implants can be adapted to the clinical need; and finally these corneal substitutes could benefit from new advances in biomaterials science, such as surface coating, functionalization and nanoparticles. This review highlights critical contributions from laboratories working on corneal stromal substitutes. It focuses on synthetic inert prostheses (keratoprostheses), acellular scaffolds with and without enhancement of endogenous regeneration, and cell-based replacements. Accent is put on the physical properties and biocompatibility of these biomaterials, on the functional and clinical outcome once transplanted in vivo in animal or human eyes, as well as on the main challenges of corneal stromal replacement. Regulatory and economic aspects are also discussed. All of these perspectives combined highlight the founding principles of the clinical application of corneal stromal replacement, a concept that has now become reality. Copyright © 2017 Elsevier Ltd. All rights reserved.
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following information: WARNING: CONTACT WITH SKIN AND EYES IS HARMFUL —Severe skin and eye irritant.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing... water. FIRST AID: —In case of eye contact, immediately flush with plenty of water and get immediate...
76 FR 24499 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: June 16, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...
78 FR 73867 - National Eye Institute; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-09
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of a meeting of the National Advisory Eye Council. The meeting will be... Advisory Eye Council. Date: January 23, 2014. Open: 8:30 a.m. to 2:00 p.m. Agenda: Following opening...
75 FR 54642 - National Eye Institute; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to the...: National Advisory Eye Council. Date: October 21, 2010. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...
76 FR 53687 - National Eye Institute Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: October 13, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...
77 FR 2076 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: February 2, 2012. Open: 8 a.m. to 12 p.m. Agenda: Following opening...
77 FR 31032 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-24
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: June 14, 2012. Open: 8:00 a.m. to 3:00 p.m. Agenda: Following opening...
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...
40 CFR 156.70 - Precautionary statements for human hazards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...
77 FR 55852 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: October 4, 2012. Open: 8:30 a.m. to 2 p.m. Agenda: Following opening...
75 FR 26260 - National Eye Institute; Amended Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute; Amended Notice of Meeting Notice is hereby given of a change in the meeting of the National Eye Institute Special Emphasis Panel, April 20, 2010, 3 p.m., to April 20, 2010, 4 p.m., National Eye Institute, 5635...
75 FR 76474 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: January 20, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Evaluation of In Vitro Tests for Identifying Eye Injury...-animal testing strategies proposed for identifying eye injury hazard potential of chemicals and products... Panel and submission of data from substances tested in in vitro tests for identifying eye injury hazard...
77 FR 73037 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-07
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), Notice is Hereby Given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: January 10, 2013. Open: 8:30 a.m. to 2:00 p.m. Agenda: Following...
75 FR 11551 - National Eye Institute; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of a meeting of the National Advisory Eye Council. The meeting will be...: National Advisory Eye Council. Date: June 17, 2010. Closed: 8:30 a.m. to 11 a.m. Agenda: To review and...
Eye Movements During Everyday Behavior Predict Personality Traits.
Hoppe, Sabrina; Loetscher, Tobias; Morey, Stephanie A; Bulling, Andreas
2018-01-01
Besides allowing us to perceive our surroundings, eye movements are also a window into our mind and a rich source of information on who we are, how we feel, and what we do. Here we show that eye movements during an everyday task predict aspects of our personality. We tracked eye movements of 42 participants while they ran an errand on a university campus and subsequently assessed their personality traits using well-established questionnaires. Using a state-of-the-art machine learning method and a rich set of features encoding different eye movement characteristics, we were able to reliably predict four of the Big Five personality traits (neuroticism, extraversion, agreeableness, conscientiousness) as well as perceptual curiosity only from eye movements. Further analysis revealed new relations between previously neglected eye movement characteristics and personality. Our findings demonstrate a considerable influence of personality on everyday eye movement control, thereby complementing earlier studies in laboratory settings. Improving automatic recognition and interpretation of human social signals is an important endeavor, enabling innovative design of human-computer systems capable of sensing spontaneous natural user behavior to facilitate efficient interaction and personalization.
NASA Astrophysics Data System (ADS)
Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun
2006-06-01
This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.
Course for undergraduate students: analysis of the retinal image quality of a human eye model
NASA Astrophysics Data System (ADS)
del Mar Pérez, Maria; Yebra, Ana; Fernández-Oliveras, Alicia; Ghinea, Razvan; Ionescu, Ana M.; Cardona, Juan C.
2014-07-01
In teaching of Vision Physics or Physiological Optics, the knowledge and analysis of the aberration that the human eye presents are of great interest, since this information allows a proper evaluation of the quality of the retinal image. The objective of the present work is that the students acquire the required competencies which will allow them to evaluate the optical quality of the human visual system for emmetropic and ammetropic eye, both with and without the optical compensation. For this purpose, an optical system corresponding to the Navarro-Escudero eye model, which allows calculating and evaluating the aberration of this eye model in different ammetropic conditions, was developed employing the OSLO LT software. The optical quality of the visual system will be assessed through determinations of the third and fifth order aberration coefficients, the impact diagram, wavefront analysis, calculation of the Point Spread Function and the Modulation Transfer Function for ammetropic individuals, with myopia or hyperopia, both with or without the optical compensation. This course is expected to be of great interest for student of Optics and Optometry Sciences, last courses of Physics or medical sciences related with human vision.
NASA Astrophysics Data System (ADS)
Traxler, Lukas; Reutterer, Bernd; Bayer, Natascha; Drauschke, Andreas
2017-04-01
To treat cataract intraocular lenses (IOLs) are used to replace the clouded human eye lens. Due to postoperative healing processes the IOL can displace within the eye, which can lead to deteriorated quality of vision. To test and characterize these effect an IOL can be embedded into a model of the humane eye. One informative measure are wavefront aberrations. In this paper three different setups, the typical double-pass configuration (DP), a single-pass (SP1) where the measured light travels in the same direction as in DP and a single-pass (SP2) with reversed direction, are investigated. All three setups correctly measure the aberrations of the eye, where SP1 is found to be the simplest to set up and align. Because of the lowest complexity it is the proposed method for wavefront measurement in model eyes.
Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell
2015-08-23
To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.
Kaluzhny, Yulia; Kandárová, Helena; d’Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell
2015-01-01
To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492. PMID:26325674
MEMS scanner mirror based system for retina scanning and in eye projection
NASA Astrophysics Data System (ADS)
Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich
2015-02-01
Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.
Evaluation of an eye-pointer interaction device for human-computer interaction.
Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián
2018-03-01
Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.
Eibenberger, Karin; Eibenberger, Bernhard; Rucci, Michele
2016-08-01
The precise measurement of eye movements is important for investigating vision, oculomotor control and vestibular function. The magnetic scleral search coil technique is one of the most precise measurement techniques for recording eye movements with very high spatial (≈ 1 arcmin) and temporal (>kHz) resolution. The technique is based on measuring voltage induced in a search coil through a large magnetic field. This search coil is embedded in a contact lens worn by a human subject. The measured voltage is in direct relationship to the orientation of the eye in space. This requires a magnetic field with a high homogeneity in the center, since otherwise the field inhomogeneity would give the false impression of a rotation of the eye due to a translational movement of the head. To circumvent this problem, a bite bar typically restricts head movement to a minimum. However, the need often emerges to precisely record eye movements under natural viewing conditions. To this end, one needs a uniform magnetic field that is uniform over a large area. In this paper, we present the numerical and finite element simulations of the magnetic flux density of different coil geometries that could be used for search coil recordings. Based on the results, we built a 2.2 × 2.2 × 2.2 meter coil frame with a set of 3 × 4 coils to generate a 3D magnetic field and compared the measured flux density with our simulation results. In agreement with simulation results, the system yields a highly uniform field enabling high-resolution recordings of eye movements.
A Fiber Optic Probe for the Detection of Cataracts
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; Dhadwal, Harbans S.
1993-01-01
A compact fiber optic probe developed for on-orbit science experiments was used to detect the onset of cataracts, a capability that could eliminate physicians' guesswork and result in new drugs to 'dissolve' or slow down the cataract formation before surgery is necessary. The probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for excised but intact human eye lenses. In a clinical setting, the device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics. In this set-up, the integrated fiber optic probe, the size of a pencil, delivers a low power cone of laser light into the eye of a patient and guides the light which is backscattered by the protein molecules of the lens through a receiving optical fiber to a photo detector. The non-invasive DLS measurements provide rapid determination of protein crystalline size and its size distribution in the eye lens.
Statis omnidirectional stereoscopic display system
NASA Astrophysics Data System (ADS)
Barton, George G.; Feldman, Sidney; Beckstead, Jeffrey A.
1999-11-01
A unique three camera stereoscopic omnidirectional viewing system based on the periscopic panoramic camera described in the 11/98 SPIE proceedings (AM13). The 3 panoramic cameras are equilaterally combined so each leg of the triangle approximates the human inter-ocular spacing allowing each panoramic camera to view 240 degree(s) of the panoramic scene, the most counter clockwise 120 degree(s) being the left eye field and the other 120 degree(s) segment being the right eye field. Field definition may be by green/red filtration or time discrimination of the video signal. In the first instance a 2 color spectacle is used in viewing the display or in the 2nd instance LCD goggles are used to differentiate the R/L fields. Radially scanned vidicons or re-mapped CCDs may be used. The display consists of three vertically stacked 120 degree(s) segments of the panoramic field of view with 2 fields/frame. Field A being the left eye display and Field B the right eye display.
Effect of aberrations in human eye on contrast sensitivity function
NASA Astrophysics Data System (ADS)
Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi
2011-06-01
The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.
Toward a digital camera to rival the human eye
NASA Astrophysics Data System (ADS)
Skorka, Orit; Joseph, Dileepan
2011-07-01
All things considered, electronic imaging systems do not rival the human visual system despite notable progress over 40 years since the invention of the CCD. This work presents a method that allows design engineers to evaluate the performance gap between a digital camera and the human eye. The method identifies limiting factors of the electronic systems by benchmarking against the human system. It considers power consumption, visual field, spatial resolution, temporal resolution, and properties related to signal and noise power. A figure of merit is defined as the performance gap of the weakest parameter. Experimental work done with observers and cadavers is reviewed to assess the parameters of the human eye, and assessment techniques are also covered for digital cameras. The method is applied to 24 modern image sensors of various types, where an ideal lens is assumed to complete a digital camera. Results indicate that dynamic range and dark limit are the most limiting factors. The substantial functional gap, from 1.6 to 4.5 orders of magnitude, between the human eye and digital cameras may arise from architectural differences between the human retina, arranged in a multiple-layer structure, and image sensors, mostly fabricated in planar technologies. Functionality of image sensors may be significantly improved by exploiting technologies that allow vertical stacking of active tiers.
2016-09-19
REPORT TYPE 3. DATES COVERED (From - To) 21-10-16 Conference Proceedings 10/2015 – 03/2016 4. TITLE AND SUBTITLE Which eye tracker is right for...Force Research Laboratory 711th Human Performance Wing Airman Systems Directorate Warfighter Interface Division Applied Neuroscience Branch Wright...88ABW-2016-1334; Human Factors and Ergonomics Society 2016 Annual Meeting 19 – 23 Sept 2016 14. Though not often mentioned, the price point of many
Digital image analysis: improving accuracy and reproducibility of radiographic measurement.
Bould, M; Barnard, S; Learmonth, I D; Cunningham, J L; Hardy, J R
1999-07-01
To assess the accuracy and reproducibility of a digital image analyser and the human eye, in measuring radiographic dimensions. We experimentally compared radiographic measurement using either an image analyser system or the human eye with digital caliper. The assessment of total hip arthroplasty wear from radiographs relies on both the accuracy of radiographic images and the accuracy of radiographic measurement. Radiographs were taken of a slip gauge (30+/-0.00036 mm) and slip gauge with a femoral stem. The projected dimensions of the radiographic images were calculated by trigonometry. The radiographic dimensions were then measured by blinded observers using both techniques. For a single radiograph, the human eye was accurate to 0.26 mm and reproducible to +/-0.1 mm. In comparison the digital image analyser system was accurate to 0.01 mm with a reproducibility of +/-0.08 mm. In an arthroplasty model, where the dimensions of an object were corrected for magnification by the known dimensions of a femoral head, the human eye was accurate to 0.19 mm, whereas the image analyser system was accurate to 0.04 mm. The digital image analysis system is up to 20 times more accurate than the human eye, and in an arthroplasty model the accuracy of measurement increases four-fold. We believe such image analysis may allow more accurate and reproducible measurement of wear from standard follow-up radiographs.
Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.
Song, Hui; Yuan, Xiaoyong; Tang, Xin
2016-01-11
In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.
Ferraroni, Marta; Lucarini, Laura; Masini, Emanuela; Korsakov, Mikhail; Scozzafava, Andrea; Supuran, Claudiu T; Krasavin, Mikhail
2017-09-01
Two lead 1,3-oxazole-based carbonic anhydrase inhibitors (CAIs) earlier identified as selective, picomolar inhibitors of hCA II (a cytosolic target for treatment of glaucoma) have been investigated further. Firstly, they were found to be conveniently synthesized on multigram scale, which enables further development. These compounds were found to be comparable in efficacy to dorzolamide eye drops when applied in the eye drop form as well. Finally, the reasons for unusually high potency of these compounds became understood from their high-resolution X-ray crystallography structures. These data significantly expand our understanding of heterocycle-based primary sulfonamides, many of which have recently emerged from our labs - particularly, from the corneal permeability standpoint. Copyright © 2017 Elsevier Ltd. All rights reserved.
Swooping in the Suburbs; Parental Defence of an Abundant Aggressive Urban Bird against Humans
Lees, Daniel; Sherman, Craig D. H.; Maguire, Grainne S.; Dann, Peter; Cardilini, Adam P. A.; Weston, Michael A.
2013-01-01
Simple Summary We studied the defensive behaviour of 94 pairs of nesting Masked Lapwings, Vanellus miles, in response to two types of human stimuli: a pedestrian and a person pushing a lawn mower. We also examined the effectiveness of a commonly promoted deterrent to swooping (the presence of mock eyes placed on the back of a person’s head) for each stimulus type. Masked Lapwings responded more aggressively to a person pushing a lawn mower compared with pedestrians. Birds also remained closer to the nest in the presence of a lawn mower. The presence of eye stickers on the back of a pedestrian’s head decreased swooping behaviour; however, the presence of eye stickers worn by a person pushing a lawn mower increased swooping behaviour. Abstract Masked Lapwings, Vanellus miles, often come into ‘conflict’ with humans, because they often breed in close proximity to humans and actively defend their ground nests through aggressive behaviour, which typically involves swooping. This study examined whether defensive responses differed when nesting birds were confronted with different human stimuli (‘pedestrian alone’ vs. ‘person pushing a lawn mower’ approaches to nests) and tested the effectiveness of a commonly used deterrent (mock eyes positioned on the top or back of a person’s head) on the defensive response. Masked Lapwings did not swoop closer to a person with a lawn mower compared with a pedestrian, but flushed closer and remained closer to the nest in the presence of a lawn mower. The presence of eye stickers decreased (pedestrians) and increased (lawn mowers) swooping behaviour. Masked Lapwings can discriminate between different human activities and adjust their defensive behaviour accordingly. We also conclude that the use of eye stickers is an effective method to mitigate the human-lapwing ‘conflict’ in some, but not all, circumstances. PMID:26479532
Li, Bing; Sheng, Minjie; Xie, Liqi; Liu, Feng; Yan, Guoquan; Wang, Weifang; Lin, Anjuan; Zhao, Fei; Chen, Yihui
2014-01-09
Diabetes mellitus has been shown to be associated with and complicated by dry eye syndrome. We sought to examine and compare the tear film proteome of type 2 diabetic patients with or without dry eye syndrome and normal subjects using two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (MS)-based proteomics. Tears were collected from eight type 2 diabetes patients with dry eye syndrome, eight type 2 diabetes patients without dry eye syndrome, and eight normal subjects. Tear breakup time (BUT) was determined, and tear proteins were prepared and analyzed using two-dimensional strong cation-exchange/reversed-phase nano-scale liquid chromatography MS. All MS/MS spectra were identified by using SEQUEST against the human International Protein Index (IPI) database and the relative abundance of individual proteins was assessed by spectral counting. Tear BUT was significantly lower in patients with diabetes and dry eye syndrome than in patients with diabetes only and normal subjects. Analysis of spectral counts of tear proteins showed that, compared to healthy controls, patients with diabetes and dry eye syndrome had increased expression of apoptosis-related proteins, like annexin A1, and immunity- and inflammation-related proteins, including neutrophil elastase 2 and clusterin, and glycometabolism-related proteins, like apolipoprotein A-II. Dry eye syndrome in diabetic patients is associated with aberrant expression of tear proteins, and the findings could lead to identification of novel pathways for therapeutic targeting and new diagnostic markers.
A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.
De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor
2014-09-30
Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.
Eye/Brain/Task Testbed And Software
NASA Technical Reports Server (NTRS)
Janiszewski, Thomas; Mainland, Nora; Roden, Joseph C.; Rothenheber, Edward H.; Ryan, Arthur M.; Stokes, James M.
1994-01-01
Eye/brain/task (EBT) testbed records electroencephalograms, movements of eyes, and structures of tasks to provide comprehensive data on neurophysiological experiments. Intended to serve continuing effort to develop means for interactions between human brain waves and computers. Software library associated with testbed provides capabilities to recall collected data, to process data on movements of eyes, to correlate eye-movement data with electroencephalographic data, and to present data graphically. Cognitive processes investigated in ways not previously possible.
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2014 CFR
2014-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2013 CFR
2013-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.
Code of Federal Regulations, 2012 CFR
2012-07-01
... found to cause cancer, reproductive effects, kidney and liver effects in laboratory animals, and allergic reactions in humans; that this substance is a severe skin and eye irritant; and that the use of.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...
Protective ocular mechanisms in woodpeckers.
Wygnanski-Jaffe, T; Murphy, C J; Smith, C; Kubai, M; Christopherson, P; Ethier, C R; Levin, A V
2007-01-01
Woodpeckers possess mechanisms protecting the eye from shaking/impact. Mechanisms available to woodpeckers but not humans may help explain some eye injuries in Shaken Baby syndrome (SBS). Gross dissection and histologic examination of eyes and orbits of seven woodpeckers. All birds showed restricted axial globe movement due to the tight fit within the orbit and fascial connections between the orbital rim and sclera. The sclera was reinforced with cartilage and bone, the optic nerve lacked redundancy, and the vitreous lacked attachments to the posterior pole retina. Woodpecker eyes differ from human infants by an inability of the globe to move axially in the orbit, the sclera to deform, and the vitreous to shear the retina. These findings support current hypotheses that abusive acceleration-deceleration-induced ocular injury in human infants may be related to translation of vitreous within the globe and the globe within the orbit. The woodpecker presents a natural model resistant to mechanical forces that have some similarity to SBS.
Human Visual Search Does Not Maximize the Post-Saccadic Probability of Identifying Targets
Morvan, Camille; Maloney, Laurence T.
2012-01-01
Researchers have conjectured that eye movements during visual search are selected to minimize the number of saccades. The optimal Bayesian eye movement strategy minimizing saccades does not simply direct the eye to whichever location is judged most likely to contain the target but makes use of the entire retina as an information gathering device during each fixation. Here we show that human observers do not minimize the expected number of saccades in planning saccades in a simple visual search task composed of three tokens. In this task, the optimal eye movement strategy varied, depending on the spacing between tokens (in the first experiment) or the size of tokens (in the second experiment), and changed abruptly once the separation or size surpassed a critical value. None of our observers changed strategy as a function of separation or size. Human performance fell far short of ideal, both qualitatively and quantitatively. PMID:22319428
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
.... Patent 6, 855, 314 entitled ``AAV5 Vector for Transducing Brain Cells and Lung Cells'' [HHS Ref. No. E... sale of AAV5 based therapeutic products to be delivered to the brain, eyes and liver for treatment of... vectors and particles. The specific brain cells that are targeted by AAV5 belong to both non-neuronal...
Micro-patterned graphene-based sensing skins for human physiological monitoring
NASA Astrophysics Data System (ADS)
Wang, Long; Loh, Kenneth J.; Chiang, Wei-Hung; Manna, Kausik
2018-03-01
Ultrathin, flexible, conformal, and skin-like electronic transducers are emerging as promising candidates for noninvasive and nonintrusive human health monitoring. In this work, a wearable sensing membrane is developed by patterning a graphene-based solution onto ultrathin medical tape, which can then be attached to the skin for monitoring human physiological parameters and physical activity. Here, the sensor is validated for monitoring finger bending/movements and for recognizing hand motion patterns, thereby demonstrating its future potential for evaluating athletic performance, physical therapy, and designing next-generation human-machine interfaces. Furthermore, this study also quantifies the sensor’s ability to monitor eye blinking and radial pulse in real-time, which can find broader applications for the healthcare sector. Overall, the printed graphene-based sensing skin is highly conformable, flexible, lightweight, nonintrusive, mechanically robust, and is characterized by high strain sensitivity.
Morokuma, S; Horimoto, N; Nakano, H
2001-08-01
It is well known that 1/f characteristics in power spectral patterns exist in various biological factors including heart rate variability. In the present study, we tried to elucidate the diurnal variation in spectral properties of eye movement and heart rate variability in the human fetus at term, via continuous 24-h observation of both these parameters. Studied were five uncomplicated fetuses at term. We observed eye movement and fetal heart rate (FHR) with real-time ultrasound and Doppler cardiotocograph, respectively, and analyzed the diurnal change in spectral properties, using the maximum entropy method. In four of five cases, the slope values of power spectra for both eye movement frequency and FHR, ranging approximately between 0.5 and 1.8, indicated diurnal variation, where the slopes tended to have high values during the day and low values at night. These findings suggest that, in the human fetus at term, eye movement and FHR are under the control of a common central mechanism, and this center changes its complexity as seen through diurnal rhythm.
Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.
Tiang, Kor L; Ooi, Ean H
2016-08-01
The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Comparative effectiveness and cost-effectiveness of the implantable miniature telescope.
Brown, Gary C; Brown, Melissa M; Lieske, Heidi B; Lieske, Philip A; Brown, Kathryn S; Lane, Stephen S
2011-09-01
To assess the preference-based comparative effectiveness (human value gain) and the cost-utility (cost-effectiveness) of a telescope prosthesis (implantable miniature telescope) for the treatment of end-stage, age-related macular degeneration (AMD). A value-based medicine, second-eye model, cost-utility analysis was performed to quantify the comparative effectiveness and cost-effectiveness of therapy with the telescope prosthesis. Published, evidence-based data from the IMT002 Study Group clinical trial. Ophthalmic utilities were obtained from a validated cohort of >1000 patients with ocular diseases. Comparative effectiveness data were converted from visual acuity to utility (value-based) format. The incremental costs (Medicare) of therapy versus no therapy were integrated with the value gain conferred by the telescope prosthesis to assess its average cost-utility. The incremental value gains and incremental costs of therapy referent to (1) a fellow eye cohort and (2) a fellow eye cohort of those who underwent intra-study cataract surgery were integrated in incremental cost-utility analyses. All value outcomes and costs were discounted at a 3% annual rate, as per the Panel on Cost-Effectiveness in Health and Medicine. Comparative effectiveness was quantified using the (1) quality-adjusted life-year (QALY) gain and (2) percent human value gain (improvement in quality of life). The QALY gain was integrated with incremental costs into the cost-utility ratio ($/QALY, or US dollars expended per QALY gained). The mean, discounted QALY gain associated with use of the telescope prosthesis over 12 years was 0.7577. When the QALY loss of 0.0004 attributable to the adverse events was factored into the model, the final QALY gain was 0.7573. This resulted in a 12.5% quality of life gain for the average patient during the 12 years of the model. The average cost-utility versus no therapy for use of the telescope prosthesis was $14389/QALY. The incremental cost-utility referent to control fellow eyes was $14063/QALY, whereas the incremental cost-utility referent to fellow eyes that underwent intra-study cataract surgery was $11805/QALY. Therapy with the telescope prosthesis considerably improves quality of life and at the same time is cost-effective by conventional standards. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Effects on biological systems of reflected light from a satellite power system
NASA Technical Reports Server (NTRS)
White, M.
1981-01-01
Light reflection produced by the satellite power system and the possible effects of that light on the human eye, plants, and animals were studied. For the human eye, two cases of reflected light, might cause eye damage if viewed for too long. These cases are: (1) if, while in low Earth orbit, the orbital transfer vehicle is misaligned to reflect the Sun to Earth there exists a maximum safe fixation time for the naked eye of 42.4 secs; (2) reflection from the aluminum paint on the back of the orbital transfer vehicle, while in or near low Earth orbit, can be safely viewed by the naked eye for 129 sec. For plants and animals the intensity and timing of light are not a major problem. Ways for reducing and/or eliminating the irradiances are proposed.
NASA Astrophysics Data System (ADS)
Tornow, Ralf P.; Milczarek, Aleksandra; Odstrcilik, Jan; Kolar, Radim
2017-07-01
A parallel video ophthalmoscope was developed to acquire short video sequences (25 fps, 250 frames) of both eyes simultaneously with exact synchronization. Video sequences were registered off-line to compensate for eye movements. From registered video sequences dynamic parameters like cardiac cycle induced reflection changes and eye movements can be calculated and compared between eyes.
Simut, Ramona E; Vanderfaeillie, Johan; Peca, Andreea; Van de Perre, Greet; Vanderborght, Bram
2016-01-01
Social robots are thought to be motivating tools in play tasks with children with autism spectrum disorders. Thirty children with autism were included using a repeated measurements design. It was investigated if the children's interaction with a human differed from the interaction with a social robot during a play task. Also, it was examined if the two conditions differed in their ability to elicit interaction with a human accompanying the child during the task. Interaction of the children with both partners did not differ apart from the eye-contact. Participants had more eye-contact with the social robot compared to the eye-contact with the human. The conditions did not differ regarding the interaction elicited with the human accompanying the child.
EYE MOVEMENT RECORDING AND NONLINEAR DYNAMICS ANALYSIS – THE CASE OF SACCADES#
Aştefănoaei, Corina; Pretegiani, Elena; Optican, L.M.; Creangă, Dorina; Rufa, Alessandra
2015-01-01
Evidence of a chaotic behavioral trend in eye movement dynamics was examined in the case of a saccadic temporal series collected from a healthy human subject. Saccades are highvelocity eye movements of very short duration, their recording being relatively accessible, so that the resulting data series could be studied computationally for understanding the neural processing in a motor system. The aim of this study was to assess the complexity degree in the eye movement dynamics. To do this we analyzed the saccadic temporal series recorded with an infrared camera eye tracker from a healthy human subject in a special experimental arrangement which provides continuous records of eye position, both saccades (eye shifting movements) and fixations (focusing over regions of interest, with rapid, small fluctuations). The semi-quantitative approach used in this paper in studying the eye functioning from the viewpoint of non-linear dynamics was accomplished by some computational tests (power spectrum, portrait in the state space and its fractal dimension, Hurst exponent and largest Lyapunov exponent) derived from chaos theory. A high complexity dynamical trend was found. Lyapunov largest exponent test suggested bi-stability of cellular membrane resting potential during saccadic experiment. PMID:25698889
Bozzani, Fiammetta Maria; Griffiths, Ulla Kou; Blanchet, Karl; Schmidt, Elena
2014-02-28
VISION 2020 is a global initiative launched in 1999 to eliminate avoidable blindness by 2020. The objective of this study was to undertake a situation analysis of the Zambian eye health system and assess VISION 2020 process indicators on human resources, equipment and infrastructure. All eye health care providers were surveyed to determine location, financing sources, human resources and equipment. Key informants were interviewed regarding levels of service provision, management and leadership in the sector. Policy papers were reviewed. A health system dynamics framework was used to analyse findings. During 2011, 74 facilities provided eye care in Zambia; 39% were public, 37% private for-profit and 24% owned by Non-Governmental Organizations. Private facilities were solely located in major cities. A total of 191 people worked in eye care; 18 of these were ophthalmologists and eight cataract surgeons, equivalent to 0.34 and 0.15 per 250,000 population, respectively. VISION 2020 targets for inpatient beds and surgical theatres were met in six out of nine provinces, but human resources and spectacles manufacturing workshops were below target in every province. Inequalities in service provision between urban and rural areas were substantial. Shortage and maldistribution of human resources, lack of routine monitoring and inadequate financing mechanisms are the root causes of underperformance in the Zambian eye health system, which hinder the ability to achieve the VISION 2020 goals. We recommend that all VISION 2020 process indicators are evaluated simultaneously as these are not individually useful for monitoring progress.
Hanneken, Anne; Neikirk, Thomas; Johnson, Jennifer; Kono, Masahiro
2017-08-01
To test the hypothesis that delayed dark adaptation in patients with macular degeneration is due to an excess of free unliganded opsin (apo-opsin) and a deficiency of the visual chromophore, 11 -cis retinal, in rod outer segments. A total of 50 human autopsy eyes were harvested from donors with and without macular degeneration within 2-24 hrs. postmortem. Protocols were developed which permitted dark adaptation of normal human eyes after death and enucleation. Biochemical methods of purifying rod outer segments were optimized and the concentration of rhodopsin and apo-opsin was measured with UV-visible scanning spectroscopy. The presence of apo-opsin was calculated by measuring the difference in the rhodopsin absorption spectra before and after the addition of 11 -cis retinal. A total of 20 normal eyes and 16 eyes from donors with early, intermediate and advanced stages of macular degeneration were included in the final analysis. Dark adaptation was achieved by harvesting whole globes in low light, transferring into dark (light-proof) canisters and dissecting the globes using infrared light and image converters for visualization. Apo-opsin was readily detected in positive controls after the addition of 11 -cis retinal. Normal autopsy eyes showed no evidence of apo-opsin. Eyes with macular degeneration also showed no evidence of apo-opsin, regardless of the severity of disease. Methods have been developed to study dark adaptation in human autopsy eyes. Eyes with age-related macular degeneration do not show a deficiency of 11 -cis retinal or an excess of apo-opsin within rod outer segments.
Micro-optical artificial compound eyes.
Duparré, J W; Wippermann, F C
2006-03-01
Natural compound eyes combine small eye volumes with a large field of view at the cost of comparatively low spatial resolution. For small invertebrates such as flies or moths, compound eyes are the perfectly adapted solution to obtaining sufficient visual information about their environment without overloading their brains with the necessary image processing. However, to date little effort has been made to adopt this principle in optics. Classical imaging always had its archetype in natural single aperture eyes which, for example, human vision is based on. But a high-resolution image is not always required. Often the focus is on very compact, robust and cheap vision systems. The main question is consequently: what is the better approach for extremely miniaturized imaging systems-just scaling of classical lens designs or being inspired by alternative imaging principles evolved by nature in the case of small insects? In this paper, it is shown that such optical systems can be achieved using state-of-the-art micro-optics technology. This enables the generation of highly precise and uniform microlens arrays and their accurate alignment to the subsequent optics-, spacing- and optoelectronics structures. The results are thin, simple and monolithic imaging devices with a high accuracy of photolithography. Two different artificial compound eye concepts for compact vision systems have been investigated in detail: the artificial apposition compound eye and the cluster eye. Novel optical design methods and characterization tools were developed to allow the layout and experimental testing of the planar micro-optical imaging systems, which were fabricated for the first time by micro-optics technology. The artificial apposition compound eye can be considered as a simple imaging optical sensor while the cluster eye is capable of becoming a valid alternative to classical bulk objectives but is much more complex than the first system.
Spering, Miriam; Carrasco, Marisa
2012-01-01
Feature-based attention enhances visual processing and improves perception, even for visual features that we are not aware of. Does feature-based attention also modulate motor behavior in response to visual information that does or does not reach awareness? Here we compare the effect of feature-based attention on motion perception and smooth pursuit eye movements in response to moving dichoptic plaids–stimuli composed of two orthogonally-drifting gratings, presented separately to each eye–in human observers. Monocular adaptation to one grating prior to the presentation of both gratings renders the adapted grating perceptually weaker than the unadapted grating and decreases the level of awareness. Feature-based attention was directed to either the adapted or the unadapted grating’s motion direction or to both (neutral condition). We show that observers were better in detecting a speed change in the attended than the unattended motion direction, indicating that they had successfully attended to one grating. Speed change detection was also better when the change occurred in the unadapted than the adapted grating, indicating that the adapted grating was perceptually weaker. In neutral conditions, perception and pursuit in response to plaid motion were dissociated: While perception followed one grating’s motion direction almost exclusively (component motion), the eyes tracked the average of both gratings (pattern motion). In attention conditions, perception and pursuit were shifted towards the attended component. These results suggest that attention affects perception and pursuit similarly even though only the former reflects awareness. The eyes can track an attended feature even if observers do not perceive it. PMID:22649238
Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun
2011-01-01
To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were measured using 3-(4,5)-dimethylthiahiazo (-z-y1)-3 5-di-phenytetrazoliumromide (MTT) assay and transwell migration assay. Cell damage was determined with the lactate dehydrogenase (LDH) assay. Cell viability and median lethal time (LT₅₀) were measured by 7-amino-actinomycin D (7-AAD) staining and flow cytometry analysis. Cellular effects after exposure of HCECs to the four anti-inflammatory eye drops were concentration dependent. The differences of cellular toxicity on cell proliferation became significant at lower concentrations (<0.002%). Diclofenac Sodium Eye Drops showed significant increasing effects on cell damage and viability when compared with the other three solutions. Tobramycin & Dex Eye Drops inhibited the migration of HCECs significantly. Tobramycin & Dex Eye Drops showed the quickest effect on cell viability: the LT₅₀ was 3.28, 9.23, 10.38, and 23.80 min for Tobramycin & Dex Eye Drops, Diclofenac Sodium Eye Drops, Pranoprofen Eye Drops, and Bromfenac Sodium Hydrate Eye Drops, respectively. However, the comparisons of cellular toxicity revealed significant differences between the eye drops and their active components under the same concentration. The corneal epithelial toxicity differences among the active components of the four eye drops became significant as higher concentration (>0.020%). The four anti-inflammatory eye drops showed different cellular effects on HCECs, and the toxicity was not related with their active components, which provides new reference for the clinical application and drug research and development.
The effect of human image in B2C website design: an eye-tracking study
NASA Astrophysics Data System (ADS)
Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo
2014-09-01
On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.
Zoonotic helminths affecting the human eye
2011-01-01
Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE) may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis), food consumption (sparganosis, trichinellosis) and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis). Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs) or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber) causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears PMID:21429191
Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K
2014-05-01
In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.
NASA Technical Reports Server (NTRS)
Jex, H. R.
1971-01-01
System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.
Bernard, Florian; Deuter, Christian Eric; Gemmar, Peter; Schachinger, Hartmut
2013-10-01
Using the positions of the eyelids is an effective and contact-free way for the measurement of startle induced eye-blinks, which plays an important role in human psychophysiological research. To the best of our knowledge, no methods for an efficient detection and tracking of the exact eyelid contours in image sequences captured at high-speed exist that are conveniently usable by psychophysiological researchers. In this publication a semi-automatic model-based eyelid contour detection and tracking algorithm for the analysis of high-speed video recordings from an eye tracker is presented. As a large number of images have been acquired prior to method development it was important that our technique is able to deal with images that are recorded without any special parametrisation of the eye tracker. The method entails pupil detection, specular reflection removal and makes use of dynamic model adaption. In a proof-of-concept study we could achieve a correct detection rate of 90.6%. With this approach, we provide a feasible method to accurately assess eye-blinks from high-speed video recordings. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease
NASA Astrophysics Data System (ADS)
Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue
2014-03-01
A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural® Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application.
NASA Astrophysics Data System (ADS)
Namazi, Hamidreza; Kulish, Vladimir V.; Akrami, Amin
2016-05-01
One of the major challenges in vision research is to analyze the effect of visual stimuli on human vision. However, no relationship has been yet discovered between the structure of the visual stimulus, and the structure of fixational eye movements. This study reveals the plasticity of human fixational eye movements in relation to the ‘complex’ visual stimulus. We demonstrated that the fractal temporal structure of visual dynamics shifts towards the fractal dynamics of the visual stimulus (image). The results showed that images with higher complexity (higher fractality) cause fixational eye movements with lower fractality. Considering the brain, as the main part of nervous system that is engaged in eye movements, we analyzed the governed Electroencephalogram (EEG) signal during fixation. We have found out that there is a coupling between fractality of image, EEG and fixational eye movements. The capability observed in this research can be further investigated and applied for treatment of different vision disorders.
NASA Astrophysics Data System (ADS)
Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor
2016-03-01
Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.
Suprachoroidal Drug Delivery to the Back of the Eye Using Hollow Microneedles
Patel, Samirkumar R.; Lin, Angela S. P.; Edelhauser, Henry F.
2011-01-01
Purpose In this work, we tested the hypothesis that microneedles provide a minimally invasive method to inject particles into the suprachoroidal space for drug delivery to the back of the eye. Methods A single, hollow microneedle was inserted into the sclera, and infused nanoparticle and microparticle suspensions into the suprachoroidal space. Experiments were performed on whole rabbit, pig, and human eyes ex vivo. Particle delivery was imaged using brightfield and fluorescence microscopy as well as microcomputed tomography. Results Microneedles were shown to deliver sulforhodamine B as well as nanoparticle and microparticle suspensions into the suprachoroidal space of rabbit, pig, and human eyes. Volumes up to 35 μL were administered consistently. Optimization of the delivery device parameters showed that microneedle length, pressure, and particle size played an important role in determining successful delivery into the suprachoroidal space. Needle lengths of 800–1,000 μm and applied pressures of 250–300 kPa provided most reliable delivery. Conclusions Microneedles were shown for the first time to deliver nanoparticle and microparticle suspensions into the suprachoroidal space of rabbit, pig and human eyes. This shows that microneedles may provide a minimally invasive method for controlled drug delivery to the back of the eye. PMID:20857178
2015 Summer Series - Lee Stone - Brain Function Through the Eyes of the Beholder
2015-06-09
The Visuomotor Control Laboratory (VCL) at NASA Ames conducts neuroscience research on the link between eye movements and brain function to provide an efficient and quantitative means of monitoring human perceptual performance. The VCL aims to make dramatic improvements in mission success through analysis, experimentation, and modeling of human performance and human-automation interaction. Dr. Lee Stone elaborates on how this research is conducted and how it contributes to NASA's mission and advances human-centered design and operations of complex aerospace systems.
Yu, Chen; Smith, Linda B.
2013-01-01
The coordination of visual attention among social partners is central to many components of human behavior and human development. Previous research has focused on one pathway to the coordination of looking behavior by social partners, gaze following. The extant evidence shows that even very young infants follow the direction of another's gaze but they do so only in highly constrained spatial contexts because gaze direction is not a spatially precise cue as to the visual target and not easily used in spatially complex social interactions. Our findings, derived from the moment-to-moment tracking of eye gaze of one-year-olds and their parents as they actively played with toys, provide evidence for an alternative pathway, through the coordination of hands and eyes in goal-directed action. In goal-directed actions, the hands and eyes of the actor are tightly coordinated both temporally and spatially, and thus, in contexts including manual engagement with objects, hand movements and eye movements provide redundant information about where the eyes are looking. Our findings show that one-year-olds rarely look to the parent's face and eyes in these contexts but rather infants and parents coordinate looking behavior without gaze following by attending to objects held by the self or the social partner. This pathway, through eye-hand coupling, leads to coordinated joint switches in visual attention and to an overall high rate of looking at the same object at the same time, and may be the dominant pathway through which physically active toddlers align their looking behavior with a social partner. PMID:24236151
Computer-based simulation of the Bielschowsky head-tilt test using the SEE++ software system.
Kaltofen, Thomas; Buchberger, Michael; Priglinger, Siegfried
2008-01-01
Latest measurements of the vestibulo-ocular reflex (VOR) allowed the integration of the simulation of the Bielschowsky head-tilt test (BHTT) into the SEE++ software system. SEE++ realizes a biomechanical model of the human eye in order to simulate eye motility disorders and strabismus surgeries. With the addition of the BHTT it can now also be used for differential-diagnostic simulations of complex disorders (e.g., superior oblique palsies). In order to simulate the BHTT in SEE++, the user can freely choose the desired head-tilt angle from -45 degrees to +45 degrees. The chosen angle is shown in the 3D view with a human body model and is also used in the calculation of the Hess-Lancaster test. The integration of the BHTT offers an additional improvement of the possibilities for simulating eye motility disorders. Moreover, SEE++ allows the creation of a video of the "virtual patient" while tilting the head from one side to the other, which shows dynamic changes in the simulated Hess-diagrams. Comparisons of simulation results with patient-measured data showed a good correlation between the simulated and the measured data. Further comparisons with patient data are planned.
Comparative ocular anatomy of the western lowland gorilla.
Knapp, Stefanie; McCulley, James P; Alvarado, Thomas P; Hogan, R Nick
2007-01-01
To examine the lowland gorilla (Gorilla gorilla gorilla) eye and determine similarities to and differences between the mountain gorilla (Gorilla gorilla beringei) and the human eye. In addition, we compare our findings of G. g. gorilla to previous reports on the eye of this subspecies. A 13-year-old deceased male lowland gorilla and a 34-year-old deceased female lowland gorilla were included in the study. Gross and microscopic examinations of the formalin-fixed right eyeball of each gorilla were carried out. Globe dimensions of G. g. gorilla were similar to G. g. beringei and to humans. The limbal conjunctival epithelium and the choroid were densely pigmented. However, the distribution of the conjunctival pigment ring was different to that of G. g. beringei and the melanocytes of the choroid were unusually round. There were deep crypts in the anterior border layer of the iris, and the epithelium of the pars plana was uniquely irregular. Vertical corneal diameter was observed to be equal or greater than horizontal diameter in G. g. gorilla, which is in contrast to humans and to previous findings for G. g. beringei. Corneal thickness was closer to that of humans than to G. g. beringei. Posterior lens capsule thickness was noticeably greater than that of humans. Although some variation between the ocular anatomy of G. g. gorilla and G. g. beringei does exist, the gross and microscopic findings closely resemble each other in these two subspecies. In addition, the eye of Gorilla appears remarkably similar to the human eye. However, comparison of measurements with those in humans is somewhat limited because formalin-fixation can introduce tissue shrinkage and artifact.
Colitz, Carmen M H; Walsh, Michael T; McCulloch, Stephen D
2016-03-01
Cetaceans in the wild and under human care develop a variety of ocular lesions. Although they have echolocation, cetacean species have good sight, making ocular health an important part of overall health care. The cornea is the primary site of abnormalities in both populations. Typical lesions of cetaceans under human care are characterized in this retrospective review of cases. One hundred eighty animals (n = 360 eyes) were chosen from the author's ophthalmologic examination reports from different geographic areas; they included Atlantic bottlenose dolphins (Tursiops truncatus), Pacific bottle nose dolphins (Tursiopstruncatus gilli), Indopacific bottlenose dolphins (Steno bredanensis), Indopacific humpback dolphins (Sousa chinensis), and roughtooth dolphins (Steno bredanensis). These animals were examined at least once, although most were examined numerous times over many years; lesions were categorized and are described. Seventy-seven eyes from 47 animals were normal. Medial keratopathy was the most common lesion and identified in 180 eyes from 97 animals, with 83 affected bilaterally. Horizontal keratopathy was identified in 69 eyes from 41 animals, with 28 affected bilaterally. Axial keratopathy and nonspecific axial opacities were identified in 67 eyes from 44 animals, with 21 affected bilaterally. Seventy-eight eyes from 50 animals, with 28 affected bilaterally, had more than one type of corneal lesion. Cataracts were identified in 32 eyes from 19 animals, with 13 affected bilaterally. Traumatic injuries were also common and involved eyelids and cornea. Sixteen eyes from 11 animals were blind; five dolphins were blind bilaterally due to phthisis bulbi secondary to corneal perforation or severe trauma. None of the diseases had a sex predisposition; however, medial keratopathy was significantly more common as a bilateral presentation than as a unilateral presentation. Cetaceans under human care with impaired sight can use echolocation; however, ocular health should definitely be a priority in their overall health plan.
Makita, Shuichi; Kurokawa, Kazuhiro; Hong, Young-Joo; Miura, Masahiro; Yasuno, Yoshiaki
2016-01-01
This paper describes a complex correlation mapping algorithm for optical coherence angiography (cmOCA). The proposed algorithm avoids the signal-to-noise ratio dependence and exhibits low noise in vasculature imaging. The complex correlation coefficient of the signals, rather than that of the measured data are estimated, and two-step averaging is introduced. Algorithms of motion artifact removal based on non perfusing tissue detection using correlation are developed. The algorithms are implemented with Jones-matrix OCT. Simultaneous imaging of pigmented tissue and vasculature is also achieved using degree of polarization uniformity imaging with cmOCA. An application of cmOCA to in vivo posterior human eyes is presented to demonstrate that high-contrast images of patients’ eyes can be obtained. PMID:27446673
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... (202) 205-3065. Copies of non- confidential documents filed in connection with this investigation are... a complaint filed on behalf of HumanEyes Technologies, Ltd. of Jerusalem, Israel on March 28, 2012..., complainant HumanEyes Technologies filed an unopposed motion to terminate the investigation pursuant to...
Somppi, Sanni; Törnqvist, Heini; Kujala, Miiamaaria V.; Hänninen, Laura; Krause, Christina M.; Vainio, Outi
2016-01-01
Appropriate response to companions’ emotional signals is important for all social creatures. The emotional expressions of humans and non-human animals have analogies in their form and function, suggesting shared evolutionary roots, but very little is known about how animals other than primates view and process facial expressions. In primates, threat-related facial expressions evoke exceptional viewing patterns compared with neutral or positive stimuli. Here, we explore if domestic dogs (Canis familiaris) have such an attentional bias toward threatening social stimuli and whether observed emotional expressions affect dogs’ gaze fixation distribution among the facial features (eyes, midface and mouth). We recorded the voluntary eye gaze of 31 domestic dogs during viewing of facial photographs of humans and dogs with three emotional expressions (threatening, pleasant and neutral). We found that dogs’ gaze fixations spread systematically among facial features. The distribution of fixations was altered by the seen expression, but eyes were the most probable targets of the first fixations and gathered longer looking durations than mouth regardless of the viewed expression. The examination of the inner facial features as a whole revealed more pronounced scanning differences among expressions. This suggests that dogs do not base their perception of facial expressions on the viewing of single structures, but the interpretation of the composition formed by eyes, midface and mouth. Dogs evaluated social threat rapidly and this evaluation led to attentional bias, which was dependent on the depicted species: threatening conspecifics’ faces evoked heightened attention but threatening human faces instead an avoidance response. We propose that threatening signals carrying differential biological validity are processed via distinctive neurocognitive pathways. Both of these mechanisms may have an adaptive significance for domestic dogs. The findings provide a novel perspective on understanding the processing of emotional expressions and sensitivity to social threat in non-primates. PMID:26761433
Peteye detection and correction
NASA Astrophysics Data System (ADS)
Yen, Jonathan; Luo, Huitao; Tretter, Daniel
2007-01-01
Redeyes are caused by the camera flash light reflecting off the retina. Peteyes refer to similar artifacts in the eyes of other mammals caused by camera flash. In this paper we present a peteye removal algorithm for detecting and correcting peteye artifacts in digital images. Peteye removal for animals is significantly more difficult than redeye removal for humans, because peteyes can be any of a variety of colors, and human face detection cannot be used to localize the animal eyes. In many animals, including dogs and cats, the retina has a special reflective layer that can cause a variety of peteye colors, depending on the animal's breed, age, or fur color, etc. This makes the peteye correction more challenging. We have developed a semi-automatic algorithm for peteye removal that can detect peteyes based on the cursor position provided by the user and correct them by neutralizing the colors with glare reduction and glint retention.
Action perception as hypothesis testing.
Donnarumma, Francesco; Costantini, Marcello; Ambrosini, Ettore; Friston, Karl; Pezzulo, Giovanni
2017-04-01
We present a novel computational model that describes action perception as an active inferential process that combines motor prediction (the reuse of our own motor system to predict perceived movements) and hypothesis testing (the use of eye movements to disambiguate amongst hypotheses). The system uses a generative model of how (arm and hand) actions are performed to generate hypothesis-specific visual predictions, and directs saccades to the most informative places of the visual scene to test these predictions - and underlying hypotheses. We test the model using eye movement data from a human action observation study. In both the human study and our model, saccades are proactive whenever context affords accurate action prediction; but uncertainty induces a more reactive gaze strategy, via tracking the observed movements. Our model offers a novel perspective on action observation that highlights its active nature based on prediction dynamics and hypothesis testing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
A transparent projection screen based on plasmonic Ag nanocubes
NASA Astrophysics Data System (ADS)
Saito, Koichiro; Tatsuma, Tetsu
2015-12-01
A transparent and colourless projection screen is fabricated by depositing a silver nanocube sub-monolayer on a titania thin film. Backward scattering of the silver nanocubes is enhanced by titania in the blue and red regions, to which human eyes are less sensitive. As a result, this screen, which is cost-effective even for large areas, allows projection of full colour images.A transparent and colourless projection screen is fabricated by depositing a silver nanocube sub-monolayer on a titania thin film. Backward scattering of the silver nanocubes is enhanced by titania in the blue and red regions, to which human eyes are less sensitive. As a result, this screen, which is cost-effective even for large areas, allows projection of full colour images. Electronic supplementary information (ESI) available: Preparation of Ag nanocubes, calculated values for a Ag nanocube on TiO2 (Tables S1 and S2). See DOI: 10.1039/c5nr06766a
Canessa, Andrea; Gibaldi, Agostino; Chessa, Manuela; Fato, Marco; Solari, Fabio; Sabatini, Silvio P.
2017-01-01
Binocular stereopsis is the ability of a visual system, belonging to a live being or a machine, to interpret the different visual information deriving from two eyes/cameras for depth perception. From this perspective, the ground-truth information about three-dimensional visual space, which is hardly available, is an ideal tool both for evaluating human performance and for benchmarking machine vision algorithms. In the present work, we implemented a rendering methodology in which the camera pose mimics realistic eye pose for a fixating observer, thus including convergent eye geometry and cyclotorsion. The virtual environment we developed relies on highly accurate 3D virtual models, and its full controllability allows us to obtain the stereoscopic pairs together with the ground-truth depth and camera pose information. We thus created a stereoscopic dataset: GENUA PESTO—GENoa hUman Active fixation database: PEripersonal space STereoscopic images and grOund truth disparity. The dataset aims to provide a unified framework useful for a number of problems relevant to human and computer vision, from scene exploration and eye movement studies to 3D scene reconstruction. PMID:28350382
Webcam mouse using face and eye tracking in various illumination environments.
Lin, Yuan-Pin; Chao, Yi-Ping; Lin, Chung-Chih; Chen, Jyh-Horng
2005-01-01
Nowadays, due to enhancement of computer performance and popular usage of webcam devices, it has become possible to acquire users' gestures for the human-computer-interface with PC via webcam. However, the effects of illumination variation would dramatically decrease the stability and accuracy of skin-based face tracking system; especially for a notebook or portable platform. In this study we present an effective illumination recognition technique, combining K-Nearest Neighbor classifier and adaptive skin model, to realize the real-time tracking system. We have demonstrated that the accuracy of face detection based on the KNN classifier is higher than 92% in various illumination environments. In real-time implementation, the system successfully tracks user face and eyes features at 15 fps under standard notebook platforms. Although KNN classifier only initiates five environments at preliminary stage, the system permits users to define and add their favorite environments to KNN for computer access. Eventually, based on this efficient tracking algorithm, we have developed a "Webcam Mouse" system to control the PC cursor using face and eye tracking. Preliminary studies in "point and click" style PC web games also shows promising applications in consumer electronic markets in the future.
A scalable and deformable stylized model of the adult human eye for radiation dose assessment
NASA Astrophysics Data System (ADS)
El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.
2018-05-01
With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from ‑12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of ‑12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes.
Optical aberrations, retinal image quality and eye growth: Experimentation and modeling
NASA Astrophysics Data System (ADS)
Tian, Yibin
2007-12-01
Retinal image quality is important for normal eye growth. Optical aberrations are of interest for two reasons: first, they degrade retinal images; second, they might provide some cues to defocus. Higher than normal ocular aberrations have been previously associated with human myopia. However, these studies were cross-sectional in design, and only reported aberrations in terms of root mean square (RMS) errors of Zernike coefficients, a poor metric of optical quality. This dissertation presents results from investigations of ocular optical aberrations, retinal image quality and eye growth in chicks and humans. A number of techniques were utilized, including Shack-Hartmann aberrometry, high-frequency A-scan ultrasonography, ciliary nerve section (CNX), photorefractive keratectomy (PRK) as well as computer simulations and modeling. A technique to extract light scatter information from Shack-Hartmann images was also developed. The main findings of the dissertation are summarized below. In young chicks, most ocular aberrations decreased with growth in both normal and CNX eyes, and there were diurnal fluctuations in some aberrations. Modeling suggested active reduction in higher order aberrations (HOAs) during early development. Although CNX eyes manifested greater than normal HOAs, they showed near normal growth. Retinal image degradation varied greatly among individual eyes post-PRK in young chicks. Including light scatter information into analyses of retinal image quality better estimated the latter. Albino eyes showed more severe retinal image degradation than normal eyes, due to increased optical aberrations and light scatter, but their growth was similar to those of normal eyes, implying that they are relatively insensitive to retina image quality. Although the above results questioned the influence of optical aberrations on early ocular growth, some optical quality metrics, derived from optical aberrations data, could predict how much the eyes of young chicks subsequently elongated. The performance of some focus measures was very poor when non-defocus aberrations exceeded a certain level; presumably, these non-defocus aberrations might interfere with the eye's ability to interpret defocus. In anisomyopic human adults, more myopic eyes had larger anterior and vitreous chambers, greater astigmatism, and more positive spherical aberration. However, compared to isometropes, only interocular differences in spherical equivalent refractive errors were significantly increased.
The Role of Eyes and Mouth in the Memory of a Face
ERIC Educational Resources Information Center
McKelvie, Stuart J.
1976-01-01
Investigates the relative importance that the eyes and mouth play in the representation in memory of a human face. Systematically applies two kinds of transformation--masking the eyes or the mouths on photographs of faces--and observes the effects on recognition. (Author/RK)
NASA Astrophysics Data System (ADS)
Kong, Jing
This thesis includes 4 pieces of work. In Chapter 1, we present the work with a method for examining mortality as it is seen to run in families, and lifestyle factors that are also seen to run in families, in a subpopulation of the Beaver Dam Eye Study that has died by 2011. We find significant distance correlations between death ages, lifestyle factors, and family relationships. Considering only sib pairs compared to unrelated persons, distance correlation between siblings and mortality is, not surprisingly, stronger than that between more distantly related family members and mortality. Chapter 2 introduces a feature screening procedure with the use of distance correlation and covariance. We demonstrate a property for distance covariance, which is incorporated in a novel feature screening procedure based on distance correlation as a stopping criterion. The approach is further implemented to two real examples, namely the famous small round blue cell tumors data and the Cancer Genome Atlas ovarian cancer data Chapter 3 pays attention to the right censored human longevity data and the estimation of lifetime expectancy. We propose a general framework of backward multiple imputation for estimating the conditional lifetime expectancy function and the variance of the estimator in the right censoring setting and prove the properties of the estimator. In addition, we apply the method to the Beaver Dam eye study data to study human longevity, where the expected human lifetime are modeled with smoothing spline ANOVA based on the covariates including baseline age, gender, lifestyle factors and disease variables. Chapter 4 compares two imputation methods for right censored data, namely the famous Buckley-James estimator and the backward imputation method proposed in Chapter 3 and shows that backward imputation method is less biased and more robust with heterogeneity.
2010-03-01
1979). As drivers’ daily commuting times increase, and as new technologies such as Blackberrys , navigation systems, DVDs, etc., become more pervasive...Thomas, L.C., & Wickens, C.D. (2001). Visual displays and cognitive tunneling : frames of reference effects on spatial judgments and change
Curved Saccade Trajectories Reveal Conflicting Predictions in Associative Learning
ERIC Educational Resources Information Center
Koenig, Stephan; Lachnit, Harald
2011-01-01
We report how the trajectories of saccadic eye movements are affected by memory interference acquired during associative learning. Human participants learned to perform saccadic choice responses based on the presentation of arbitrary central cues A, B, AC, BC, AX, BY, X, and Y that were trained to predict the appearance of a peripheral target…
Mitochondrial DNA common deletion in the human eye: a relation with corneal aging.
Gendron, Sébastien P; Mallet, Justin D; Bastien, Nathalie; Rochette, Patrick J
2012-01-01
The most frequent mitochondrial DNA (mtDNA) mutation is a 4977 bp deletion known as the common deletion (mtDNA(CD4977)). mtDNA(CD4977) is related to skin photo-aging and to chronological aging of cells with high-energy demands such as neurons and muscle cells. The human eye contains both sun-exposed (cornea, iris) and high-energy demand structures (retina). In this study, we employed a highly sensitive quantitative PCR technique to determine mtDNA(CD4977) occurrence in different structures of the human eye. We found that the cornea, the most anterior structure of the eye, contains the highest amount of mtDNA(CD4977) (2.6%, 0.25% and 0.06% for the cornea, iris and retina, respectively). Within the cornea, mtDNA(CD4977) is almost exclusively found in the stroma, the cellular layer conferring transparency and rigidity to the human cornea (8.59%, 0.13% and 0.05% in the stroma, endothelium and epithelium, respectively). Moreover, we show that mtDNA(CD4977) accumulates with age in the corneal stroma. Taken together, our results suggest that mtDNA(CD4977) is related to photo-aging rather than chronological aging in the human eye. Similar to the involvement of mtDNA(CD4977) in skin photo-aging phenotypes, we believe that the clinical manifestations of corneal aging, including clouding and stiffening, are associated with the accumulation of mtDNA(CD4977) in the corneal stroma. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
McCamy, Michael B.; Otero-Millan, Jorge; Leigh, R. John; King, Susan A.; Schneider, Rosalyn M.; Macknik, Stephen L.; Martinez-Conde, Susana
2015-01-01
Human eyes move continuously, even during visual fixation. These “fixational eye movements” (FEMs) include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift) and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs. PMID:26035820
Swooping in the Suburbs; Parental Defence of an Abundant Aggressive Urban Bird against Humans.
Lees, Daniel; Sherman, Craig D H; Maguire, Grainne S; Dann, Peter; Cardilini, Adam P A; Weston, Michael A
2013-08-13
Masked Lapwings, Vanellus miles, often come into 'conflict' with humans, because they often breed in close proximity to humans and actively defend their ground nests through aggressive behaviour, which typically involves swooping. This study examined whether defensive responses differed when nesting birds were confronted with different human stimuli ('pedestrian alone' vs. 'person pushing a lawn mower' approaches to nests) and tested the effectiveness of a commonly used deterrent (mock eyes positioned on the top or back of a person's head) on the defensive response. Masked Lapwings did not swoop closer to a person with a lawn mower compared with a pedestrian, but flushed closer and remained closer to the nest in the presence of a lawn mower. The presence of eye stickers decreased (pedestrians) and increased (lawn mowers) swooping behaviour. Masked Lapwings can discriminate between different human activities and adjust their defensive behaviour accordingly. We also conclude that the use of eye stickers is an effective method to mitigate the human-lapwing 'conflict' in some, but not all, circumstances.
Optics of human eye: 400 years of exploration from Galileo's time.
Artal, Pablo; Tabernero, Juan
2010-06-01
We present a brief historical background and a description of the main features of the eye's optical properties: the eye is a simple, but rather optimized, optical instrument. It is only since Galileo's time that the importance of the eye as a part of different optical instruments has driven a continuous scientific exploration of ocular optics. In the past decade, the use of wavefront sensing technology allowed us to complete our understating of eye optics as a robust aplanatic system.
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity. PMID:27957500
Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Velez-Montoya, Raul; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio
2016-01-01
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF 6 , 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF 6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF 6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.
Pizzi, Rita; Wang, Rui; Rossetti, Danilo
2016-01-01
This paper describes a computational approach to the theoretical problems involved in the Young's single-photon double-slit experiment, focusing on a simulation of this experiment in the absence of measuring devices. Specifically, the human visual system is used in place of a photomultiplier or similar apparatus. Beginning with the assumption that the human eye perceives light in the presence of very few photons, we measure human eye performance as a sensor in a double-slit one-photon-at-a-time experimental setup. To interpret the results, we implement a simulation algorithm and compare its results with those of human subjects under identical experimental conditions. In order to evaluate the perceptive parameters exactly, which vary depending on the light conditions and on the subject’s sensitivity, we first review the existing literature on the biophysics of the human eye in the presence of a dim light source, and then use the known values of the experimental variables to set the parameters of the computational simulation. The results of the simulation and their comparison with the experiment involving human subjects are reported and discussed. It is found that, while the computer simulation indicates that the human eye has the capacity to detect the corpuscular nature of photons under these conditions, this was not observed in practice. The possible reasons for the difference between theoretical prediction and experimental results are discussed. PMID:26816029
Meena, Yogesh Kumar; Cecotti, Hubert; Wong-Lin, Kongfatt; Dutta, Ashish; Prasad, Girijesh
2018-04-01
Virtual keyboard applications and alternative communication devices provide new means of communication to assist disabled people. To date, virtual keyboard optimization schemes based on script-specific information, along with multimodal input access facility, are limited. In this paper, we propose a novel method for optimizing the position of the displayed items for gaze-controlled tree-based menu selection systems by considering a combination of letter frequency and command selection time. The optimized graphical user interface layout has been designed for a Hindi language virtual keyboard based on a menu wherein 10 commands provide access to type 88 different characters, along with additional text editing commands. The system can be controlled in two different modes: eye-tracking alone and eye-tracking with an access soft-switch. Five different keyboard layouts have been presented and evaluated with ten healthy participants. Furthermore, the two best performing keyboard layouts have been evaluated with eye-tracking alone on ten stroke patients. The overall performance analysis demonstrated significantly superior typing performance, high usability (87% SUS score), and low workload (NASA TLX with 17 scores) for the letter frequency and time-based organization with script specific arrangement design. This paper represents the first optimized gaze-controlled Hindi virtual keyboard, which can be extended to other languages.
78 FR 56905 - National Eye Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory Committee Act, as amended (5 U... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Career Development...
21 CFR 886.3200 - Artificial eye.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... device resembling the anterior portion of the eye, usually made of glass or plastic, intended to be...
21 CFR 886.3200 - Artificial eye.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... device resembling the anterior portion of the eye, usually made of glass or plastic, intended to be...
21 CFR 886.3200 - Artificial eye.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... device resembling the anterior portion of the eye, usually made of glass or plastic, intended to be...
Opening our eyes to Global Health; a philosophy of universal values.
Wass, Val
2015-12-01
Globalization is advancing at a pace. As we strive to introduce 'Global Health' into clinical curricula we risk fundamental misunderstandings unless we clearly define what we aim to achieve. Clinicians must be prepared for a life time of uncertainty, change and challenge. The fluctuating world arena will undoubtedly impact on their future work in ways we cannot predict. Population migration, climate change and shifts in cultural dominance are already at play. Global health risks being translated through the eyes of Western ideology as disease-based curricula focused paternalistically on 'helping' the developing world. We must not lack humility to open eyes to learning within the context of increasingly diverse environments and patient populations. Global health is as 'local' as it is 'international'. It should be viewed, I argue, as a philosophy based on the values and expectations found within ourselves and our communities. Responding to globalization lies not only in knowledge but embraces human rights, justice and, most importantly, self-awareness. Knowledge is more easily translated into curriculum objectives. We risk letting future clinicians and their patients down if we ignore the other universal values.
Contribution of Spaceflight Environmental Factors to Vision Risks
NASA Technical Reports Server (NTRS)
Zanello, Susana B.
2011-01-01
The risk of visual impairment and elevated intracranial pressure as a result of low-earth orbit microgravity exposure has directed our attention and research efforts to the eye. While the alterations observed in astronauts returning from long duration missions include vision and neuroanatomical changes observed by non-invasive methods, other effects and subsequent tissue responses at the molecular and cellular level can only be studied by accessing the tissue itself. As a result of this need, several studies are currently taking place within the Human and Health Countermeasures Element (HHC) that use animal models for eye research. The rodent eye has many similarities to the human eye, and both rats and mice have historically been used as models of human eye disease, aiding in the identification of the disease genes, elucidation of mechanisms of disease, as well as in the assessment of therapeutic treatments. These studies attempt to answer two central questions in the etiology of possible vision alterations in the environment of space exploration missions. The first is: what effects and response mechanisms take place in the different eye structures at the cellular and molecular level? The second question is directed to elucidate the contribution of the various environmental stressors (radiation, nutrition, fluid shift) to these effects. Collaborative approaches with internal and external investigators have allowed performing these studies in a most cost-effective fashion, providing preliminary data and laying the bases for testing further hypotheses in future and specifically designed animal experiments. From a study centered on the radioadaptive response in mice, we have learned that the retina responds to low and high dose gamma radiation by elevating antioxidant-related genes at early time points (4hrs) and that this response returns to control levels after 1 day post-irradiation. We are expanding this research with another collaborative study that investigates the combined effects of radiation exposure and iron overload on sensitivity to radiation injury in rat eyes. All main eye structures will be analyzed in this study: retina, lens and cornea. A study in collaboration with the Space Human Factors and Habitability Element (SHFH) investigates the effects of lunar dust exposure on the rat cornea. It is anticipated that common underlying oxidative stress mechanisms of damage may be observed as a result of these three stressors: radiation, nutritional iron and lunar dust. The contribution of fluid shift is addressed by a study using rats subjected to hindlimb suspension. The hypothesis to be tested in this study is that the mechanical stress imparted by the pressure differential across the optic disc and lamina cribosa will impact oxygenation (therefore causing oxidative stress and hypoxia) and cell survival. This study also includes the assessment of two nutritional antioxidant countermeasures: epigallocatechin gallate (green tea) and resveratrol. Finally, as a result of two successful tissue sharing efforts, we are proceeding with the analysis of eye samples of mice aboard two shuttle missions: STS-133 and STS-135. Results from the STS-133 study are presented in an independent abstract. Briefly, the results show that spaceflight represents a source of environmental stress that directly translates into oxidative and cellular stress in the retina. Similar analysis is also planned for the cornea. These samples add large value to our current vision research as they provide data on the direct effects of low-earth orbit spaceflight on eye structures and physiology.
Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task.
Bott, Nicholas T; Lange, Alex; Rentz, Dorene; Buffalo, Elizabeth; Clopton, Paul; Zola, Stuart
2017-01-01
Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive "window on the brain," and the recording of eye movements using web cameras is a burgeoning area of research. Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC) decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS)] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS). Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera. Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits ( r = 0.88-0.92). Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81-0.88). There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets ( r = 0.88-0.94). Significantly fewer data quality issues were encountered using the built-in web camera. Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as fixation points, built-in web cameras are a standard feature of most smart devices (e.g., laptops, tablets, smart phones) and can be effectively employed to track eye movements on decisional tasks with high accuracy and minimal cost.
Labrador Velandia, Sonia; Di Lauro, Salvatore; Alonso-Alonso, Maria Luz; Tabera Bartolomé, Soraya; Srivastava, Girish Kumar; Pastor, José Carlos; Fernandez-Bueno, Ivan
2018-01-01
To evaluate the feasibility, safety, and biocompatibility of intravitreal injection of human mesenchymal stem cells (MSCs) in immunocompetent pigmented rabbits. Thirty-two pigmented rabbits (24 females, 8 males; Chinchilla-New Zealand White) were divided into 8 groups of 4 animals. Commercially prepared human MSCs were injected (0.05 ml) into the post-lens vitreous of the right eyes. Groups 1 and 4 received isotonic medium (Ringer lactate-based), groups 2, 5, 7, and 8 received a low dose of 15 × 10 6 cells/ml. Groups 3 and 6 received a high dose of 30 × 10 6 cells/ml. Clinical signs were evaluated and scored before MSCs injection and weekly for 2 or 6 weeks. Animals were sacrificed at 2 or 6 weeks after injection. Eyes, liver, spleen, and gonads were assessed by histology and by fluorescent in situ hybridization to evaluate survival and extraocular migration of MSCs. There were no relevant clinical findings between control and MSC-injected rabbit eyes at any time point. There were also no relevant histological findings between control and MSC-injected rabbits related to ocular, liver, spleen, or gonad tissues modifications. MSCs survived intravitreally for at least 2 weeks after injection. Extraocular migration of MSCs was not detected. MSCs are safe and well-tolerated when administered intravitreally at a dose of 15 × 10 6 cells/ml in pigmented rabbits. These findings enable future research to explore the intravitreal use of commercially prepared allogenic human MSCs in clinical trials of retinal diseases.
Eye Dominance Predicts fMRI Signals in Human Retinotopic Cortex
Mendola, Janine D.; Conner, Ian P.
2009-01-01
There have been many attempts to define eye dominance in normal subjects, but limited consensus exists, and relevant physiological data is scarce. In this study, we consider two different behavioral methods for assignment of eye dominance, and how well they predict fMRI signals evoked by monocular stimulation. Sighting eye dominance was assessed with two standard tests, the Porta Test, and a ‘hole in hand’ variation of the Miles Test. Acuity dominance was tested with a standard eye chart and with a computerized test of grating acuity. We found limited agreement between the sighting and acuity methods for assigning dominance in our individual subjects. We then compared the fMRI response generated by dominant eye stimulation to that generated by non-dominant eye, according to both methods, in 7 normal subjects. The stimulus consisted of a high contrast hemifield stimulus alternating with no stimulus in a blocked paradigm. In separate scans, we used standard techniques to label the borders of visual areas V1, V2, V3, VP, V4, V3A, and MT. These regions of interest (ROIs) were used to analyze each visual area separately. We found that percent change in fMRI BOLD signal was stronger for the dominant eye as defined by the acuity method, and this effect was significant for areas located in the ventral occipital territory (V1v, V2v, VP, V4). In contrast, assigning dominance based on sighting produced no significant interocular BOLD differences. We conclude that interocular BOLD differences in normal subjects exist, and may be predicted by acuity measures. PMID:17194544
Wave study of compound eyes for efficient infrared detection
NASA Astrophysics Data System (ADS)
Kilinc, Takiyettin Oytun; Hayran, Zeki; Kocer, Hasan; Kurt, Hamza
2017-08-01
Improving sensitivity in the infrared spectrum is a challenging task. Detecting infrared light over a wide bandwidth and at low power consumption is very important. Novel solutions can be acquired by mimicking biological eyes such as compound eye with many individual lenses inspired from the nature. The nature provides many ingenious approaches of sensing and detecting the surrounding environment. Even though compound eye consists of small optical units, it can detect wide-angle electromagnetic waves and it has high transmission and low reflection loss. Insects have eyes that are superior compared to human eyes (single-aperture eyes) in terms of compactness, robustness, wider field of view, higher sensitivity of light intensity and being cheap vision systems. All these desired properties are accompanied by an important drawback: lower spatial resolution. The first step to investigate the feasibility of bio-inspired optics in photodetectors is to perform light interaction with the optical system that gather light and detect it. The most common method used in natural vision systems is the ray analysis. Light wave characteristics are not taken into consideration in such analyses, such as the amount of energy at the focal point or photoreceptor site, the losses caused by reflection at the interfaces and absorption cannot be investigated. In this study, we present a bio-inspired optical detection system investigated by wave analysis. We numerically model the wave analysis based on Maxwell equations from the viewpoint of efficient light detection and revealing the light propagation after intercepting the first interface of the eye towards the photoreceptor site.
Inertial Movements of the Iris as the Origin of Postsaccadic Oscillations.
Bouzat, S; Freije, M L; Frapiccini, A L; Gasaneo, G
2018-04-27
Recent studies on the human eye indicate that the pupil moves inside the eyeball due to deformations of the iris. Here we show that this phenomenon can be originated by inertial forces undergone by the iris during the rotation of the eyeball. Moreover, these forces affect the iris in such a way that the pupil behaves effectively as a massive particle. To show this, we develop a model based on the Newton equation on the noninertial reference frame of the eyeball. The model allows us to reproduce and interpret several important findings of recent eye-tracking experiments on saccadic movements. In particular, we get correct results for the dependence of the amplitude and period of the postsaccadic oscillations on the saccade size and also for the peak velocity. The model developed may serve as a tool for characterizing eye properties of individuals.
Inertial Movements of the Iris as the Origin of Postsaccadic Oscillations
NASA Astrophysics Data System (ADS)
Bouzat, S.; Freije, M. L.; Frapiccini, A. L.; Gasaneo, G.
2018-04-01
Recent studies on the human eye indicate that the pupil moves inside the eyeball due to deformations of the iris. Here we show that this phenomenon can be originated by inertial forces undergone by the iris during the rotation of the eyeball. Moreover, these forces affect the iris in such a way that the pupil behaves effectively as a massive particle. To show this, we develop a model based on the Newton equation on the noninertial reference frame of the eyeball. The model allows us to reproduce and interpret several important findings of recent eye-tracking experiments on saccadic movements. In particular, we get correct results for the dependence of the amplitude and period of the postsaccadic oscillations on the saccade size and also for the peak velocity. The model developed may serve as a tool for characterizing eye properties of individuals.
Working sketch of an anatomically and optically equivalent physical model eye
NASA Astrophysics Data System (ADS)
Bakaraju, Ravi Chandra; Ehrmann, Klaus; Falk, Darrin; Papas, Eric B.; Ho, Arthur
2009-02-01
Our aim was to fabricate a bench-top physical model eye that closely replicates anatomical and optical properties of the average human eye, and to calibrate and standardize this model to suit normal viewing conditions and subsequently utilize it to understand the optical performance of corrective lens designs; especially multifocal soft contact lenses. Using available normative data on ocular biometrics and Zemax ray-tracing software as a tool, we modeled 25, 45 and 55 year-old average adult human eyes with discrete accommodation levels and pupil sizes. Specifications for the components were established following manufacturing tolerance analyses. The cornea was lathed from an optical material with refractive index of 1.376 @ 589 nm and the crystalline lenses were made of Boston RGP polymers with refractive indices of 1.423 (45 & 55yr) and 1.429 (25yr) @ 589 nm. These two materials served to model the equivalent crystalline lens of the different age-groups. A camera, the acting retina, was hosted on the motor-base having translatory and rotary functions to facilitate the simulation of different states of ametropia and peripheral refraction respectively. We report on the implementation of the first prototype and present some simulations of the optical performance of certain contact lenses with specific levels of ametropia, to demonstrate the potential use of such a physical model eye. On completion of development, calibration and standardization, optical quality assessment and performance predictions of different ophthalmic lenses can be studied in great detail. Optical performance with corrective lenses may be reliably simulated and predicted by customized combined computational and physical models giving insight into the merits and pitfalls of their designs
Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell
2015-05-01
The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.
May, Christian Albrecht
2005-01-01
To characterize further non-vascular smooth muscle cells (NVSMC) in the choroid of the human eye, extensive morphological studies were performed including a three-dimensional distribution of NVSMC in the adult human eye and their appearance during development. Whole mounts and sections through the choroid and sclera of eyes of 42 human donors (between the 13th week of gestation and 89 years of age) were stained with antibodies against smooth muscle actin and other markers for smooth muscle cells. On the basis of their morphological localization, three groups of NVSMC could be distinguished in the adult eyes: (a) a semicircular arrangement of NVSMC in the suprachoroid and inner sclera, around the entry of posterior ciliary arteries and nerves; (b) NVSMC parallel to the vessels in the posterior eye segment between the point of entry of the posterior ciliary arteries and the point of exit of the vortex veins; and (c) a dense plaque-like arrangement of NVSMC in the suprachoroid, overlying the foveal region. The last of these groups showed most pronounced interindividual differences. During development, the first NVSMC to be observed at the 20th week of gestation belonged to group b. A complete NVSMC network was first observed in a 6-year-old donor eye. All three groups stained positive for smoothelin, caldesmon and calponin in all localizations. The NVSMC show a distinct distribution that might reflect different aspects of their function in the choroid and suprachoroid. All cells could be histochemically characterized as truly contractile. PMID:16191166
2014-01-01
Background VISION 2020 is a global initiative launched in 1999 to eliminate avoidable blindness by 2020. The objective of this study was to undertake a situation analysis of the Zambian eye health system and assess VISION 2020 process indicators on human resources, equipment and infrastructure. Methods All eye health care providers were surveyed to determine location, financing sources, human resources and equipment. Key informants were interviewed regarding levels of service provision, management and leadership in the sector. Policy papers were reviewed. A health system dynamics framework was used to analyse findings. Results During 2011, 74 facilities provided eye care in Zambia; 39% were public, 37% private for-profit and 24% owned by Non-Governmental Organizations. Private facilities were solely located in major cities. A total of 191 people worked in eye care; 18 of these were ophthalmologists and eight cataract surgeons, equivalent to 0.34 and 0.15 per 250,000 population, respectively. VISION 2020 targets for inpatient beds and surgical theatres were met in six out of nine provinces, but human resources and spectacles manufacturing workshops were below target in every province. Inequalities in service provision between urban and rural areas were substantial. Conclusion Shortage and maldistribution of human resources, lack of routine monitoring and inadequate financing mechanisms are the root causes of underperformance in the Zambian eye health system, which hinder the ability to achieve the VISION 2020 goals. We recommend that all VISION 2020 process indicators are evaluated simultaneously as these are not individually useful for monitoring progress. PMID:24575919
Tong, Louis; Zhou, Xi Yuan; Jylha, Antti; Aapola, Ulla; Liu, Dan Ning; Koh, Siew Kwan; Tian, Dechao; Quah, Joanne; Uusitalo, Hannu; Beuerman, Roger W; Zhou, Lei
2015-02-06
Tear proteins are intimately related to the pathophysiology of the ocular surface. Many recent studies have demonstrated that the tear is an accessible fluid for studying eye diseases and biomarker discovery. This study describes a high resolution multiple reaction monitoring (HR-MRM) approach for developing assays for quantification of biologically important tear proteins. Human tear samples were collected from 1000 subjects with no eye complaints (411 male, 589 female, average age: 55.5±14.5years) after obtaining informed consent. Tear samples were collected using Schirmer's strips and pooled into a single global control sample. Quantification of proteins was carried out by selecting "signature" peptides derived by trypsin digestion. A 1-h nanoLC-MS/MS run was used to quantify the tear proteins in HR-MRM mode. Good reproducibility of signal intensity (using peak areas) was demonstrated for all 47 HR-MRM assays with an average coefficient of variation (CV%) of 4.82% (range: 1.52-10.30%). All assays showed consistent retention time with a CV of less than 0.80% (average: 0.57%). HR-MRM absolute quantitation of eight tear proteins was demonstrated using stable isotope-labeled peptides. In this study, we demonstrated for the first time the technique to quantify 47 human tear proteins in HR-MRM mode using approximately 1μl of human tear sample. These multiplexed HR-MRM-based assays show great promise of further development for biomarker validation in human tear samples. Both discovery-based and targeted quantitative proteomics can be achieved in a single quadrupole time-of-flight mass spectrometer platform (TripleTOF 5600 system). Copyright © 2015 Elsevier B.V. All rights reserved.
Predicting the Valence of a Scene from Observers’ Eye Movements
R.-Tavakoli, Hamed; Atyabi, Adham; Rantanen, Antti; Laukka, Seppo J.; Nefti-Meziani, Samia; Heikkilä, Janne
2015-01-01
Multimedia analysis benefits from understanding the emotional content of a scene in a variety of tasks such as video genre classification and content-based image retrieval. Recently, there has been an increasing interest in applying human bio-signals, particularly eye movements, to recognize the emotional gist of a scene such as its valence. In order to determine the emotional category of images using eye movements, the existing methods often learn a classifier using several features that are extracted from eye movements. Although it has been shown that eye movement is potentially useful for recognition of scene valence, the contribution of each feature is not well-studied. To address the issue, we study the contribution of features extracted from eye movements in the classification of images into pleasant, neutral, and unpleasant categories. We assess ten features and their fusion. The features are histogram of saccade orientation, histogram of saccade slope, histogram of saccade length, histogram of saccade duration, histogram of saccade velocity, histogram of fixation duration, fixation histogram, top-ten salient coordinates, and saliency map. We utilize machine learning approach to analyze the performance of features by learning a support vector machine and exploiting various feature fusion schemes. The experiments reveal that ‘saliency map’, ‘fixation histogram’, ‘histogram of fixation duration’, and ‘histogram of saccade slope’ are the most contributing features. The selected features signify the influence of fixation information and angular behavior of eye movements in the recognition of the valence of images. PMID:26407322
Postanaesthetic tear production and ocular irritation in cats.
Peche, N; Köstlin, R; Reese, S; Pieper, K
2015-01-01
General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro
2013-12-01
Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.
A generalised porous medium approach to study thermo-fluid dynamics in human eyes.
Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal
2018-03-22
The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.
What Do the Prospective Science Teachers Know about the Human Eye?
ERIC Educational Resources Information Center
Sahin, Çigdem
2014-01-01
In this study, the views of the Prospective Science Teacher (PST)s about the human eye were examined. The following data collection tools were used: the Word Association Test (WAT), open ended questions, drawing technique, two tiered question item and an interview about concepts. The data of the study whose sample consisted of 34 PSTs were…
Tseng, Ching-Li; Seghatchian, Jerard; Burnouf, Thierry
2015-08-01
There is much interest in the clinical use of serum-converted human blood or platelet concentrates in regenerative medicine, most specifically for wound healing and tissue repair of soft and hard tissues. The scientific rationale supporting the clinical efficacy of these preparations is based on the expectation that their physiological mixture of natural growth factors can orchestrate cell expansion and differentiation in vivo. However, a lack of standardization and regulatory oversight of these blood materials maintain a perception of uncertainty in the scientific and medical community on the value of these preparations for some clinical indications. More studies are needed to understand the mechanism of action underlying their expected efficacy and standardize their use, and benefit from their biological versatility. One application of serum is as eye drop for treating dry eye syndrome (DES), a multifactorial disease of the ocular surface, which has a prevalence of 15% of more in the population. DES can lead to chronic inflammation of the ocular surface, surface impairment in the cornea and conjunctiva, and, in patients with Sjogren syndrome, result in a disruption of the ocular surface epithelium. Objective experimental assessment of safety and efficacy of serum eye drops can help establish scientific rationale in optimal product composition and use. This can be achieved, first, through cell cultures with relevant cell models, before considering, then, animal studies using DES animal models. Several models have been evaluated and are reported in this concise review. The model we have developed encompasses the use of rabbits, where their eyes are treated with 0.1% benzalkonium chloride (BAC), a common preservative in ophthalmic agents, 3 times daily for 4 weeks. This relatively mild treatment results in moderate DES pathology, with a stable shortage of tear secretion throughout a 7-week study period, which we found suitable for assessing efficacy of serum eye drops. Copyright © 2015 Elsevier Ltd. All rights reserved.
Temporal accommodation response measured by photorefractive accommodation measurement device
NASA Astrophysics Data System (ADS)
Song, Byoungsub; Leportier, Thibault; Park, Min-Chul
2017-02-01
Although accommodation response plays an important role in the human vision system for perception of distance, some three-dimensional (3D) displays offer depth stimuli regardless of the accommodation response. The consequence is that most observers watching 3D displays have complained about visual fatigue. The measurement of the accommodation response is therefore necessary to develop human-friendly 3D displays. However, only few studies about accommodation measurement have been reported. Most of the investigations have been focused on the measurement and analysis of monocular accommodation responses only because the accommodation response works individually in each eye. Moreover, a main eye perceives dominantly the object distance. However, the binocular accommodation response should be examined because both eyes are used to watch the 3D display in natural conditions. The ophthalmic instrument that we developed enabled to measure changes in the accommodation response of the two eyes simultaneously. Two cameras acquired separately the infrared images reflected from each eyes after the reflected beams passed through a cylindrical lens. The changes in the accommodation response could then be estimated from the changes in the astigmatism ratio of the infrared images that were acquired in real time. In this paper, we compared the accommodation responses of main eye between the monocular and the binocular conditions. The two eyes were measured one by one, with only one eye opened, during measurement for monocular condition. Then the two eyes were examined simultaneously for binocular condition. The results showed similar tendencies for main eye accommodation response in both cases.
Ipsiversive ictal eye deviation in inferioposterior temporal lobe epilepsy-Two SEEG cases report.
Zhang, Wei; Liu, Xingzhou; Zuo, Lijun; Guo, Qiang; Chen, Qi; Wang, Yongjun
2017-02-21
Versive seizure characterized by conjugate eye movement during epileptic seizure has been considered commonly as one of the most valuable semiological signs for epilepsy localization, especially for frontal lobe epilepsy. However, the lateralizing and localizing significance of ictaleye deviation has been questioned by clinical observation of a series of focal epilepsy studies, including frontal, central, temporal, parietal and occipital epilepsy. Two epileptic cases characterized by ipsiversive eye deviation as initial clinical sign during the habitual epileptic seizures are presented in this paper. The localization of the epileptogenic zone of both of the cases has been confirmed as inferioposterior temporal region by the findings of ictalstereoelectroencephalography (SEEG) and a good result after epileptic surgery. Detailed analysis of the exact position of the key contacts of the SEEG electrodes identified the overlap between the location of the epileptogenic zone and human MT/MST complex, which play a crucial role in the control of smooth pursuit eye movement. Ipsiversive eye deviation could be the initial clinical sign of inferioposterior temporal lobe epilepsy and attribute to the involvement of human MT/MST complex, especially human MST whichwas located on the anterior/dorsal bank of the anterior occipital sulcus (AOS).
New eye phantom for ophthalmic surgery
NASA Astrophysics Data System (ADS)
Fogli, Gessica; Orsi, Gianni; De Maria, Carmelo; Montemurro, Francesca; Palla, Michele; Rizzo, Stanislao; Vozzi, Giovanni
2014-06-01
In this work, we designed and realized a new phantom able to mimic the principal mechanical, rheological, and physical cues of the human eye and that can be used as a common benchmark to validate new surgical procedures, innovative vitrectomes, and as a training system for surgeons. This phantom, in particular its synthetic humor vitreous, had the aim of reproducing diffusion properties of the natural eye and can be used as a system to evaluate the pharmacokinetics of drugs and optimization of their dose, limiting animal experiments. The eye phantom was built layer-by-layer starting from the sclera up to the retina, using low cost and easy to process polymers. The validation of the phantom was carried out by mechanical characterization of each layer, by diffusion test with commercial drugs into a purposely developed apparatus, and finally by a team of ophthalmic surgeons. Experiments demonstrated that polycaprolactone, polydimethylsiloxane, and gelatin, properly prepared, are the best materials to mimic the mechanical properties of sclera, choroid, and retina, respectively. A polyvinyl alcohol-gelatin polymeric system is the best for mimicking the viscosity of the human humor vitreous, even if the bevacizumab half-life is lower than in the human eye.
Yusof, Nor Zuliana; Abd Gani, Siti Salwa; Azizul Hasan, Zafarizal Aldrin; Idris, Zainab
2018-01-01
Many types of phytochemicals have been found to be present in oil palm leaf and could potentially be used as functional ingredients for skincare product. However, as of today, there is no published report on hazard identification and safety assessment of oil palm ( Elaeis guineensis) leaf extract (OPLE), particularly on skin and eye irritation. In this study, potential hazard of OPLE on skin and eye irritation was evaluated as an initial step to the safety assessment of OPLE. In vitro cell viability study of OPLE on normal human dermal fibroblasts showed that OPLE was nontoxic to the cells with percentage viability more than 90% after 24 and 48 hours of incubation. Skin irritation potential of OPLE was evaluated using in vitro SkinEthic reconstructed human epidermis (RHE) model (Organization for Economic Cooperation and Development [OECD] Test Guideline 439, 2015), while eye irritation potential was evaluated using in vitro SkinEthic Human corneal epithelium (HCE) model (OECD test guideline 492, 2017). Hazard identification results showed that OPLE at 1%, 5%, and 10% (wt/wt) was classified as nonirritant to the skin and eye where mean tissue viabilities of SkinEthic RHE and SkinEthic HCE were more than 50% and 60%, respectively. Therefore, we recommend a further safety assessment, such as human patch testing, to confirm the nonirritant of OPLE.
How dogs know when communication is intended for them.
Kaminski, Juliane; Schulz, Linda; Tomasello, Michael
2012-03-01
Domestic dogs comprehend human gestural communication in a way that other animal species do not. But little is known about the specific cues they use to determine when human communication is intended for them. In a series of four studies, we confronted both adult dogs and young dog puppies with object choice tasks in which a human indicated one of two opaque cups by either pointing to it or gazing at it. We varied whether the communicator made eye contact with the dog in association with the gesture (or whether her back was turned or her eyes were directed at another recipient) and whether the communicator called the dog's name (or the name of another recipient). Results demonstrated the importance of eye contact in human-dog communication, and, to a lesser extent, the calling of the dog's name--with no difference between adult dogs and young puppies--which are precisely the communicative cues used by human infants for identifying communicative intent. Unlike human children, however, dogs did not seem to comprehend the human's communicative gesture when it was directed to another human, perhaps because dogs view all human communicative acts as directives for the recipient. © 2011 Blackwell Publishing Ltd.
[Pressure-reducing effect of latanoprost 0.005%].
Albach, C; Wachsmuth, E D; Velte, K; Dekker, P; Robert, Y
1998-05-01
Earlier studies in monkeys have shown that latanoprost 0.005% lowers the IOP by improving the uveoscleral Outflow. We wanted to know if this is also the case in the human eye. We used our new aqueous humor outflow test with 2-nitrophenyl-acetate in 9 healthy human volunteers, mean age 32 +/- 8.3 years. They were measured before and 12 h after receiving one drop of latanoprost 0.005% in one eye, randomly chosen. The ocular Photometer was used to quantify the disappearance of the dye out of the anterior chamber. The half-life time of the dye is shortened after latanoprost 0.005%. It is significantly correlated to the pressure lowering effect of latanoprost 0.005% (r2 = 0.5968). The dye-dilution technique proves that latanoprost 0.005% influences the outflow of the human eye. The better the outflow, the greater the pressure drop in the eye. The experiment nicely shows that photometric quantification of 2-nitrophenyl-acetate is a simple, reliable test for the knowledge of the aqueous humor outflow.
Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong
2012-07-20
Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Training for eye contact modulates gaze following in dogs.
Wallis, Lisa J; Range, Friederike; Müller, Corsin A; Serisier, Samuel; Huber, Ludwig; Virányi, Zsófia
2015-08-01
Following human gaze in dogs and human infants can be considered a socially facilitated orientation response, which in object choice tasks is modulated by human-given ostensive cues. Despite their similarities to human infants, and extensive skills in reading human cues in foraging contexts, no evidence that dogs follow gaze into distant space has been found. We re-examined this question, and additionally whether dogs' propensity to follow gaze was affected by age and/or training to pay attention to humans. We tested a cross-sectional sample of 145 border collies aged 6 months to 14 years with different amounts of training over their lives. The dogs' gaze-following response in test and control conditions before and after training for initiating eye contact with the experimenter was compared with that of a second group of 13 border collies trained to touch a ball with their paw. Our results provide the first evidence that dogs can follow human gaze into distant space. Although we found no age effect on gaze following, the youngest and oldest age groups were more distractible, which resulted in a higher number of looks in the test and control conditions. Extensive lifelong formal training as well as short-term training for eye contact decreased dogs' tendency to follow gaze and increased their duration of gaze to the face. The reduction in gaze following after training for eye contact cannot be explained by fatigue or short-term habituation, as in the second group gaze following increased after a different training of the same length. Training for eye contact created a competing tendency to fixate the face, which prevented the dogs from following the directional cues. We conclude that following human gaze into distant space in dogs is modulated by training, which may explain why dogs perform poorly in comparison to other species in this task.
NASA Astrophysics Data System (ADS)
Panova, Ina G.; Tatikolov, Alexander S.
2009-02-01
We used one of cyanine dyes as a spectral and fluorescent probe in the study of the composition of the extracellular matrix of the human eye (its vitreous body). Owing to the unique ability of the dye to bind to collagens and human serum albumin, we revealed the simultaneous presence of both types of biomacromolecules in the vitreous body. The formation of the dye complex with human serum albumin leads to appearance of a long-wavelength absorption band (~612 nm) and a steep rise of fluorescence, whereas in the presence of collagens the dye forms J-aggregates with a longer-wavelength absorption band (640-660 nm) and moderate fluorescence. In this work we studied the composition of the human fetus vitreous body and its dynamics from 9 to 31 gestation weeks. On the basis of the data obtained by this method, we may assume that albumin, being a carrier protein, probably provides the vitreous body and surrounding tissues with necessary growth factors, hormones, lipids, vitamins, and some other biomolecules. The data show that the dye is promising not only for study of albumin functions in eye development, but also for characterization of some eye diseases and for analysis of other extracellular media.
An overview of applied visibility fundamentals: Survey and synthesis of a visibility literature
NASA Astrophysics Data System (ADS)
1982-06-01
The concept of visibility has been defined in numerous ways. One source that is widely used in the United States describes visibility as the greatest distance at which it is just possible to see and identify selected objects or light sources with the unaided eye, or, it may be considered the distance an observer would have to back away from a target before it disappears. The process by which we see distant objects is based on the characteristics of the target, its immediate surroundings, air quality, illumination of the sight path, and the eyes and brain of the observer. Thus, four components of visibility have been noted: (1) target, (2) background, (3) atmosphere, and (4) observer. Most definitions of visibility include the observer as a key element, but it is also possible to measure visibility without the immediate presence of humans by means of instruments such as telephotometers, transmissometers, or nephelometers. Such measurements can be kept in non-dimensional terms and can be compared without human intervention. When used in the field, however, visibility sensors must be calibrated in human terms of visibility measurement.
Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T
1999-05-01
Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the VOR does not become apparent until 47 ms after the onset of the stimulus. In contrast, the response to active high acceleration stimuli shows eye position-dependence from within 5 ms of the onset of the stimulus. A model using a VOR-Listing's law compromise strategy did not accurately predict the patterns observed in the data, raising questions about how the eye position-dependence of the VOR is generated. We suggest, in view of recent findings, that the phenomenon could arise due to the effects of fibromuscular pulleys on the functional pulling directions of the rectus muscles.
NASA Technical Reports Server (NTRS)
Beutter, B. R.; Mulligan, J. B.; Stone, L. S.; Hargens, Alan R. (Technical Monitor)
1995-01-01
We have shown that moving a plaid in an asymmetric window biases the perceived direction of motion (Beutter, Mulligan & Stone, ARVO 1994). We now explore whether these biased motion signals might also drive the smooth eye-movement response by comparing the perceived and tracked directions. The human smooth oculomotor response to moving plaids appears to be driven by the perceived rather than the veridical direction of motion. This suggests that human motion perception and smooth eye movements share underlying neural motion-processing substrates as has already been shown to be true for monkeys.
Can eye-tracking technology improve situational awareness in paramedic clinical education?
Williams, Brett; Quested, Andrew; Cooper, Simon
2013-01-01
Human factors play a significant part in clinical error. Situational awareness (SA) means being aware of one's surroundings, comprehending the present situation, and being able to predict outcomes. It is a key human skill that, when properly applied, is associated with reducing medical error: eye-tracking technology can be used to provide an objective and qualitative measure of the initial perception component of SA. Feedback from eye-tracking technology can be used to improve the understanding and teaching of SA in clinical contexts, and consequently, has potential for reducing clinician error and the concomitant adverse events.
78 FR 64517 - National Eye Institute; Amended Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute; Amended Notice of Meeting Notice is hereby given of a change in the meeting of the National Eye Institute Special Emphasis Panel, October 21, 2013, 08:00 a.m. to October 23, 2013, 12:00 p.m., National Institutes...
78 FR 64519 - National Eye Institute; Amended Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute; Amended Notice of Meeting Notice is hereby given of a change in the meeting of the National Advisory Eye Council, October 17, 2013, 8:30 a.m. to October 17, 2013, 5:00 p.m., NIH, Neuroscience Building, 6001...