Sample records for human eye model

  1. Implicit prosody mining based on the human eye image capture technology

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of disabled assisted speech interaction. Experiments show that Implicit Prosody mining based on the human eye image capture technology makes the synthesized speech has more flexible expressions.

  2. Integrating the Advanced Human Eye Model (AHEM) and optical instrument models to model complete visual optical systems inclusive of the typical or atypical eye

    NASA Astrophysics Data System (ADS)

    Donnelly, William J., III

    2012-06-01

    PURPOSE: To present a commercially available optical modeling software tool to assist the development of optical instrumentation and systems that utilize and/or integrate with the human eye. METHODS: A commercially available flexible eye modeling system is presented, the Advanced Human Eye Model (AHEM). AHEM is a module that the engineer can use to perform rapid development and test scenarios on systems that integrate with the eye. Methods include merging modeled systems initially developed outside of AHEM and performing a series of wizard-type operations that relieve the user from requiring an optometric or ophthalmic background to produce a complete eye inclusive system. Scenarios consist of retinal imaging of targets and sources through integrated systems. Uses include, but are not limited to, optimization, telescopes, microscopes, spectacles, contact and intraocular lenses, ocular aberrations, cataract simulation and scattering, and twin eye model (binocular) systems. RESULTS: Metrics, graphical data, and exportable CAD geometry are generated from the various modeling scenarios.

  3. A Model of the Human Eye

    ERIC Educational Resources Information Center

    Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.

    2008-01-01

    We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.

  4. Toward statistical modeling of saccadic eye-movement and visual saliency.

    PubMed

    Sun, Xiaoshuai; Yao, Hongxun; Ji, Rongrong; Liu, Xian-Ming

    2014-11-01

    In this paper, we present a unified statistical framework for modeling both saccadic eye movements and visual saliency. By analyzing the statistical properties of human eye fixations on natural images, we found that human attention is sparsely distributed and usually deployed to locations with abundant structural information. This observations inspired us to model saccadic behavior and visual saliency based on super-Gaussian component (SGC) analysis. Our model sequentially obtains SGC using projection pursuit, and generates eye movements by selecting the location with maximum SGC response. Besides human saccadic behavior simulation, we also demonstrated our superior effectiveness and robustness over state-of-the-arts by carrying out dense experiments on synthetic patterns and human eye fixation benchmarks. Multiple key issues in saliency modeling research, such as individual differences, the effects of scale and blur, are explored in this paper. Based on extensive qualitative and quantitative experimental results, we show promising potentials of statistical approaches for human behavior research.

  5. An optomechanical model eye for ophthalmological refractive studies.

    PubMed

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  6. Simulation of wave propagation inside a human eye: acoustic eye model (AEM)

    NASA Astrophysics Data System (ADS)

    Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.

    2018-02-01

    The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.

  7. Multiconjugate adaptive optics applied to an anatomically accurate human eye model.

    PubMed

    Bedggood, P A; Ashman, R; Smith, G; Metha, A B

    2006-09-04

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  8. Theoretical investigation of aberrations upon ametropic human eyes

    NASA Astrophysics Data System (ADS)

    Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin

    2003-11-01

    The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.

  9. HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu

    2009-02-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.

  10. Computational Model-Based Prediction of Human Episodic Memory Performance Based on Eye Movements

    NASA Astrophysics Data System (ADS)

    Sato, Naoyuki; Yamaguchi, Yoko

    Subjects' episodic memory performance is not simply reflected by eye movements. We use a ‘theta phase coding’ model of the hippocampus to predict subjects' memory performance from their eye movements. Results demonstrate the ability of the model to predict subjects' memory performance. These studies provide a novel approach to computational modeling in the human-machine interface.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid

    In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less

  12. FDTD analysis of temperature elevation in the lens of human and rabbit models due to near-field and far-field exposures at 2.45 GHz.

    PubMed

    Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki

    2013-07-01

    The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.

  13. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    PubMed

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    PubMed

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  15. Retinal image contrast obtained by a model eye with combined correction of chromatic and spherical aberrations

    PubMed Central

    Ohnuma, Kazuhiko; Kayanuma, Hiroyuki; Lawu, Tjundewo; Negishi, Kazuno; Yamaguchi, Takefumi; Noda, Toru

    2011-01-01

    Correcting spherical and chromatic aberrations in vitro in human eyes provides substantial visual acuity and contrast sensitivity improvements. We found the same improvement in the retinal images using a model eye with/without correction of longitudinal chromatic aberrations (LCAs) and spherical aberrations (SAs). The model eye included an intraocular lens (IOL) and artificial cornea with human ocular LCAs and average human SAs. The optotypes were illuminated using a D65 light source, and the images were obtained using two-dimensional luminance colorimeter. The contrast improvement from the SA correction was higher than the LCA correction, indicating the benefit of an aspheric achromatic IOL. PMID:21698008

  16. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    PubMed

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  17. Human Commercial Models' Eye Colour Shows Negative Frequency-Dependent Selection.

    PubMed

    Forti, Isabela Rodrigues Nogueira; Young, Robert John

    2016-01-01

    In this study we investigated the eye colour of human commercial models registered in the UK (400 female and 400 male) and Brazil (400 female and 400 male) to test the hypothesis that model eye colour frequency was the result of negative frequency-dependent selection. The eye colours of the models were classified as: blue, brown or intermediate. Chi-square analyses of data for countries separated by sex showed that in the United Kingdom brown eyes and intermediate colours were significantly more frequent than expected in comparison to the general United Kingdom population (P<0.001). In Brazil, the most frequent eye colour brown was significantly less frequent than expected in comparison to the general Brazilian population. These results support the hypothesis that model eye colour is the result of negative frequency-dependent selection. This could be the result of people using eye colour as a marker of genetic diversity and finding rarer eye colours more attractive because of the potential advantage more genetically diverse offspring that could result from such a choice. Eye colour may be important because in comparison to many other physical traits (e.g., hair colour) it is hard to modify, hide or disguise, and it is highly polymorphic.

  18. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  19. Speckle measuring instrument based on biological characteristics of the human eyes and speckle reduction with advanced electromagnetic micro-scanning mirror

    NASA Astrophysics Data System (ADS)

    Yuan, Yuan; Fang, Tao; Sun, Min Yuan; Gao, Wei Nan; Zhang, Shuo; Bi, Yong

    2018-07-01

    Laser speckle is a major issue for laser projection displays. In various techniques of speckle reduction, speckle is quantified with a speckle contrast value. However, the measured speckle contrast is poorly suited for the subjective speckle perception of a human observer. Here, we investigate the characteristics of human eyes and propose a simplified optical transfer function of human eyes. Accordingly, two human-eye-modeled speckle measuring sets are configured. Based on the experimental set, an advanced electromagnetic micro-scanning mirror (EM-MSM) is exploited; which is of 6.5 mm in diameter and its half angle is 7.8° for a horizontal scan and 6.53° for a vertical scan. Finally, we quantitatively show that images generated with an EM-MSM exhibit superior quality. By providing human-eye-modeled speckle measuring instruments and an EM-MSM for speckle reduction, it has a promising promotion to laser projector development.

  20. An eye model for uncalibrated eye gaze estimation under variable head pose

    NASA Astrophysics Data System (ADS)

    Hnatow, Justin; Savakis, Andreas

    2007-04-01

    Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.

  1. Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™.

    PubMed

    Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min

    2015-09-01

    Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.

  2. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

    PubMed Central

    Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-01-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556

  3. Model of the Human Eye Based on ABCD Matrix

    NASA Astrophysics Data System (ADS)

    González, G. Díaz; Castillo, M. David Iturbe

    2008-04-01

    At the moment several models of the human eye exist, nevertheless the gradient index models of the human lens (crystalline) have received little attention in optometry and vision sciences, although they consider how the refractive index and the refracting power can change with the accommodation. On the other hand, in study fields like ophthalmology and optometry, exist cases where there is a lack of information about the factors that influence the change of refractive power and therefore the focal length of the eye. By such reason, in this paper we present a model of the human eye based on the ABCD matrix in order to describe the propagation of light rays, that can be understood by professional people in optics, ophthalmology and optometry, and the dispersions of the different ocular mediums are taken into account,. The aim of the model is to obtain data about the refractive power of the eye under different considerations, such as: changes in wavelength, radius of curvature and thicknesses of the ocular mediums. We present results of simulations in Matlab of our model, assuming that the object is punctual and is placed to a certain distance of the eye, and considering at the beginning to the crystalline like a medium with fixed refractive index, and after like a gradient lens. By means of graphs, we show the total refractive power of the eye and its form and type of dependence with respect to variations in radius of curvature and thicknesses of the cornea and crystalline, as well as variations in the thickness of the previous and later cameras.

  4. A scalable and deformable stylized model of the adult human eye for radiation dose assessment

    NASA Astrophysics Data System (ADS)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.

    2018-05-01

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from  ‑12 to  +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of  ‑12D and  +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes.

  5. Double-pass measurement of human eye aberrations: limitations and practical realization

    NASA Astrophysics Data System (ADS)

    Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.

    2004-11-01

    The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.

  6. Computing the stresses and deformations of the human eye components due to a high explosive detonation using fluid-structure interaction model.

    PubMed

    Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu

    2016-05-01

    In spite the fact that a very small human body surface area is comprised by the eye, its wounds due to detonation have recently been dramatically amplified. Although many efforts have been devoted to measure injury of the globe, there is still a lack of knowledge on the injury mechanism due to Primary Blast Wave (PBW). The goal of this study was to determine the stresses and deformations of the human eye components, including the cornea, aqueous, iris, ciliary body, lens, vitreous, retina, sclera, optic nerve, and muscles, attributed to PBW induced by trinitrotoluene (TNT) explosion via a Lagrangian-Eulerian computational coupling model. Magnetic Resonance Imaging (MRI) was employed to establish a Finite Element (FE) model of the human eye according to a normal human eye. The solid components of the eye were modelled as Lagrangian mesh, while an explosive TNT, air domain, and aqueous were modelled using Arbitrary Lagrangian-Eulerian (ALE) mesh. Nonlinear dynamic FE simulations were accomplished using the explicit FE code, namely LS-DYNA. In order to simulate the blast wave generation, propagation, and interaction with the eye, the ALE formulation with Jones-Wilkins-Lee (JWL) equation defining the explosive material were employed. The results revealed a peak stress of 135.70kPa brought about by detonation upsurge on the cornea at the distance of 25cm. The highest von Mises stresses were observed on the sclera (267.3kPa), whereas the lowest one was seen on the vitreous body (0.002kPa). The results also showed a relatively high resultant displacement for the macula as well as a high variation for the radius of curvature for the cornea and lens, which can result in both macular holes, optic nerve damage and, consequently, vision loss. These results may have implications not only for understanding the value of stresses and strains in the human eye components but also giving an outlook about the process of PBW triggers damage to the eye. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Dose conversion coefficients for neutron exposure to the lens of the human eye.

    PubMed

    Manger, R P; Bellamy, M B; Eckerman, K F

    2012-03-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 × 10(-9) to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  9. Study of Light Scattering in the Human Eye

    NASA Astrophysics Data System (ADS)

    Perez, I. Kelly; Bruce, N. C.; Valdos, L. R. Berriel

    2008-04-01

    In this paper we present a numerical model of the human eye to be used in studies of the scattering of light in different components of the eye's optical system. Different parts of the eye are susceptible to produce scattering for different reasons; age, illness or injury. For example, cataracts can appear in the human lens or injuries or fungi can appear on the cornea. The aim of the study is to relate the backscattered light, which is what doctors measure or detect, to the forward scattered light, which is what affects the patient's vision. We present the model to be used, the raytrace procedure and some preliminary results for the image on the retina without scattering.

  10. Intraocular lens based on double-liquid variable-focus lens.

    PubMed

    Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2014-01-10

    In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.

  11. Comparison of different wavefront measurement setups to judge the position tolerance of intraocular lenses in a model eye

    NASA Astrophysics Data System (ADS)

    Traxler, Lukas; Reutterer, Bernd; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To treat cataract intraocular lenses (IOLs) are used to replace the clouded human eye lens. Due to postoperative healing processes the IOL can displace within the eye, which can lead to deteriorated quality of vision. To test and characterize these effect an IOL can be embedded into a model of the humane eye. One informative measure are wavefront aberrations. In this paper three different setups, the typical double-pass configuration (DP), a single-pass (SP1) where the measured light travels in the same direction as in DP and a single-pass (SP2) with reversed direction, are investigated. All three setups correctly measure the aberrations of the eye, where SP1 is found to be the simplest to set up and align. Because of the lowest complexity it is the proposed method for wavefront measurement in model eyes.

  12. Numerical study on statistical properties of speckle pattern in laser projection display based on human eye model

    NASA Astrophysics Data System (ADS)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2013-12-01

    In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.

  13. Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    PubMed

    Tiang, Kor L; Ooi, Ean H

    2016-08-01

    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Dose conversion coefficients for neutron exposure to the lens of the human eye

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manger, Ryan P; Bellamy, Michael B; Eckerman, Keith F

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematicalmore » phantom in the MCNPX transport calculations.« less

  15. Alternatives to In Vivo Draize Rabbit Eye and Skin Irritation Tests with a Focus on 3D Reconstructed Human Cornea-Like Epithelium and Epidermis Models

    PubMed Central

    Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min

    2017-01-01

    Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350

  16. A Theoretical Analysis of a New Polarimetric Optical Scheme for Glucose Sensing in the Human Eye

    NASA Technical Reports Server (NTRS)

    Rovati, Luigi L.; Boeckle, Stefan; Ansari, Rafat R.; Salzman, Jack A. (Technical Monitor)

    2002-01-01

    The challenging task of in vivo polarimetric glucose sensing is the identification and selection of a scheme to optically access the aqueous humor of the human eye. In this short communication an earlier approach of Cote et al. is theoretically compared with our new optical scheme. Simulations of the new scheme using the eye model of Navarro, suggest that the new optical geometry can overcome the limitations of the previous approach for in vivo measurements of glucose in a human eye.

  17. Research of the aberrations of human eyes with accommodation based on eye model

    NASA Astrophysics Data System (ADS)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The variation of the wavefront aberration with accommodation was investigated based on the eye model of Gullstrand-Le Grand. The anterior lens radius was optimized at different accommodation to focus the image at the retina, and the RMS and PV wave-front error of human eye were compared at different accommodation. The PV value of wavefront aberration from 0.718 waves increases gradually to 0.904 waves and RMS value from 0.21 waves to 0.26 waves when accommodative stimuli varies from 0 to - 5 diopters. The change of PV value is 0.186 waves which is less than the Rayleigh diffraction limit λ/4, and the change of RMS is 0.05 which under Marechal diffraction limit λ/14. Therefore, the change of the wavefront aberration caused accommodation can be ignored when wavefront aberrations in the human eye are corrected with surgery or wearing glasses.

  18. Course for undergraduate students: analysis of the retinal image quality of a human eye model

    NASA Astrophysics Data System (ADS)

    del Mar Pérez, Maria; Yebra, Ana; Fernández-Oliveras, Alicia; Ghinea, Razvan; Ionescu, Ana M.; Cardona, Juan C.

    2014-07-01

    In teaching of Vision Physics or Physiological Optics, the knowledge and analysis of the aberration that the human eye presents are of great interest, since this information allows a proper evaluation of the quality of the retinal image. The objective of the present work is that the students acquire the required competencies which will allow them to evaluate the optical quality of the human visual system for emmetropic and ammetropic eye, both with and without the optical compensation. For this purpose, an optical system corresponding to the Navarro-Escudero eye model, which allows calculating and evaluating the aberration of this eye model in different ammetropic conditions, was developed employing the OSLO LT software. The optical quality of the visual system will be assessed through determinations of the third and fifth order aberration coefficients, the impact diagram, wavefront analysis, calculation of the Point Spread Function and the Modulation Transfer Function for ammetropic individuals, with myopia or hyperopia, both with or without the optical compensation. This course is expected to be of great interest for student of Optics and Optometry Sciences, last courses of Physics or medical sciences related with human vision.

  19. The Advanced Human Eye Model (AHEM): a personal binocular eye modeling system inclusive of refraction, diffraction, and scatter.

    PubMed

    Donnelly, William

    2008-11-01

    To present a commercially available software tool for creating eye models to assist the development of ophthalmic optics and instrumentation, simulate ailments or surgery-induced changes, explore vision research questions, and provide assistance to clinicians in planning treatment or analyzing clinical outcomes. A commercially available eye modeling system was developed, the Advanced Human Eye Model (AHEM). Two mainstream optical software engines, ZEMAX (ZEMAX Development Corp) and ASAP (Breault Research Organization), were used to construct a similar software eye model and compared. The method of using the AHEM is described and various eye modeling scenarios are created. These scenarios consist of retinal imaging of targets and sources; optimization capability; spectacles, contact lens, and intraocular lens insertion and correction; Zernike surface deformation on the cornea; cataract simulation and scattering; a gradient index lens; a binocular mode; a retinal implant; system import/export; and ray path exploration. Similarity of the two different optical software engines showed validity to the mechanism of the AHEM. Metrics and graphical data are generated from the various modeling scenarios particular to their input specifications. The AHEM is a user-friendly commercially available software tool from Breault Research Organization, which can assist the design of ophthalmic optics and instrumentation, simulate ailments or refractive surgery-induced changes, answer vision research questions, or assist clinicians in planning treatment or analyzing clinical outcomes.

  20. Application of adipose-derived stem cells on scleral contact lens carrier in an animal model of severe acute alkaline burn.

    PubMed

    Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce

    2014-07-01

    To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits.

  1. Application of Adipose-Derived Stem Cells on Scleral Contact Lens Carrier in an Animal Model of Severe Acute Alkaline Burn

    PubMed Central

    Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce

    2015-01-01

    Purpose To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. Materials and Methods After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Results Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Conclusion Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits. PMID:24901976

  2. Modeling the influence of LASIK surgery on optical properties of the human eye

    NASA Astrophysics Data System (ADS)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  3. Technical vision for robots

    NASA Astrophysics Data System (ADS)

    1985-01-01

    A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.

  4. Zebrafish models of human eye and inner ear diseases.

    PubMed

    Blanco-Sánchez, B; Clément, A; Phillips, J B; Westerfield, M

    2017-01-01

    Eye and inner ear diseases are the most common sensory impairments that greatly impact quality of life. Zebrafish have been intensively employed to understand the fundamental mechanisms underlying eye and inner ear development. The zebrafish visual and vestibulo-acoustic systems are very similar to these in humans, and although not yet mature, they are functional by 5days post-fertilization (dpf). In this chapter, we show how the zebrafish has significantly contributed to the field of biomedical research and how researchers, by establishing disease models and meticulously characterizing their phenotypes, have taken the first steps toward therapies. We review here models for (1) eye diseases, (2) ear diseases, and (3) syndromes affecting eye and/or ear. The use of new genome editing technologies and high-throughput screening systems should increase considerably the speed at which knowledge from zebrafish disease models is acquired, opening avenues for better diagnostics, treatments, and therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Toward building an anatomically correct solid eye model with volumetric representation of retinal morphology

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Rowe, T. Scott; Fuller, Alfred R.; Hamann, Bernd; Werner, John S.

    2010-02-01

    An accurate solid eye model (with volumetric retinal morphology) has many applications in the field of ophthalmology, including evaluation of ophthalmic instruments and optometry/ophthalmology training. We present a method that uses volumetric OCT retinal data sets to produce an anatomically correct representation of three-dimensional (3D) retinal layers. This information is exported to a laser scan system to re-create it within solid eye retinal morphology of the eye used in OCT testing. The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power to that of the human eye (~58D). Additionally we tested a water bath eye model from Eyetech Ltd. with a customized retina consisting of five layers of ~60 μm thick biaxial polypropylene film and hot melt rubber adhesive.

  6. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    PubMed Central

    Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research. PMID:25393277

  7. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    PubMed

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  8. Learning rational temporal eye movement strategies.

    PubMed

    Hoppe, David; Rothkopf, Constantin A

    2016-07-19

    During active behavior humans redirect their gaze several times every second within the visual environment. Where we look within static images is highly efficient, as quantified by computational models of human gaze shifts in visual search and face recognition tasks. However, when we shift gaze is mostly unknown despite its fundamental importance for survival in a dynamic world. It has been suggested that during naturalistic visuomotor behavior gaze deployment is coordinated with task-relevant events, often predictive of future events, and studies in sportsmen suggest that timing of eye movements is learned. Here we establish that humans efficiently learn to adjust the timing of eye movements in response to environmental regularities when monitoring locations in the visual scene to detect probabilistically occurring events. To detect the events humans adopt strategies that can be understood through a computational model that includes perceptual and acting uncertainties, a minimal processing time, and, crucially, the intrinsic costs of gaze behavior. Thus, subjects traded off event detection rate with behavioral costs of carrying out eye movements. Remarkably, based on this rational bounded actor model the time course of learning the gaze strategies is fully explained by an optimal Bayesian learner with humans' characteristic uncertainty in time estimation, the well-known scalar law of biological timing. Taken together, these findings establish that the human visual system is highly efficient in learning temporal regularities in the environment and that it can use these regularities to control the timing of eye movements to detect behaviorally relevant events.

  9. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    PubMed

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  10. Estimating outflow facility through pressure dependent pathways of the human eye

    PubMed Central

    Gardiner, Bruce S.

    2017-01-01

    We develop and test a new theory for pressure dependent outflow from the eye. The theory comprises three main parameters: (i) a constant hydraulic conductivity, (ii) an exponential decay constant and (iii) a no-flow intraocular pressure, from which the total pressure dependent outflow, average outflow facilities and local outflow facilities for the whole eye may be evaluated. We use a new notation to specify precisely the meaning of model parameters and so model outputs. Drawing on a range of published data, we apply the theory to animal eyes, enucleated eyes and in vivo human eyes, and demonstrate how to evaluate model parameters. It is shown that the theory can fit high quality experimental data remarkably well. The new theory predicts that outflow facilities and total pressure dependent outflow for the whole eye are more than twice as large as estimates based on the Goldman equation and fluorometric analysis of anterior aqueous outflow. It appears likely that this discrepancy can be largely explained by pseudofacility and aqueous flow through the retinal pigmented epithelium, while any residual discrepancy may be due to pathological processes in aged eyes. The model predicts that if the hydraulic conductivity is too small, or the exponential decay constant is too large, then intraocular eye pressure may become unstable when subjected to normal circadian changes in aqueous production. The model also predicts relationships between variables that may be helpful when planning future experiments, and the model generates many novel testable hypotheses. With additional research, the analysis described here may find application in the differential diagnosis, prognosis and monitoring of glaucoma. PMID:29261696

  11. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    NASA Astrophysics Data System (ADS)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  12. Analysis of the effects of non-supine sleeping positions on the stress, strain, deformation and intraocular pressure of the human eye

    NASA Astrophysics Data System (ADS)

    Volpe, Peter A.

    This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.

  13. A boussinesq model of natural convection in the human eye and the formation of Krukenberg's spindle.

    PubMed

    Heys, Jeffrey J; Barocas, Victor H

    2002-03-01

    The cornea of the human eye is cooled by the surrounding air and by evaporation of the tear film. The temperature difference between the cornea and the iris (at core body temperature) causes circulation of the aqueous humor in the anterior chamber of the eye. Others have suggested that the circulation pattern governs the shape of the Krukenberg spindle, a distinctive vertical band of pigment on the posterior cornea surface in some pathologies. We modeled aqueous humor flow the human eye, treating the humor as a Boussinesq fluid and setting the corneal temperature based on infrared surface temperature measurements. The model predicts convection currents in the anterior chamber with velocities comparable to those resulting from forced flow through the gap between the iris and lens. When paths of pigment particles are calculated based on the predicted flow field, the particles circulate throughout the anterior chamber but tend to be near the vertical centerline of the eye for a greatest period of time. Further, the particles are usually in close proximity to the cornea only when they are near the vertical centerline. We conclude that the convective flow pattern of aqueous humor is consistent with a vertical pigment spindle.

  14. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  15. Development of an interactive anatomical three-dimensional eye model.

    PubMed

    Allen, Lauren K; Bhattacharyya, Siddhartha; Wilson, Timothy D

    2015-01-01

    The discrete anatomy of the eye's intricate oculomotor system is conceptually difficult for novice students to grasp. This is problematic given that this group of muscles represents one of the most common sites of clinical intervention in the treatment of ocular motility disorders and other eye disorders. This project was designed to develop a digital, interactive, three-dimensional (3D) model of the muscles and cranial nerves of the oculomotor system. Development of the 3D model utilized data from the Visible Human Project (VHP) dataset that was refined using multiple forms of 3D software. The model was then paired with a virtual user interface in order to create a novel 3D learning tool for the human oculomotor system. Development of the virtual eye model was done while attempting to adhere to the principles of cognitive load theory (CLT) and the reduction of extraneous load in particular. The detailed approach, digital tools employed, and the CLT guidelines are described herein. © 2014 American Association of Anatomists.

  16. A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

    PubMed

    Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal

    2018-03-22

    The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.

  17. High-speed adaptive optics line scan confocal retinal imaging for human eye

    PubMed Central

    Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458

  18. An information maximization model of eye movements

    NASA Technical Reports Server (NTRS)

    Renninger, Laura Walker; Coughlan, James; Verghese, Preeti; Malik, Jitendra

    2005-01-01

    We propose a sequential information maximization model as a general strategy for programming eye movements. The model reconstructs high-resolution visual information from a sequence of fixations, taking into account the fall-off in resolution from the fovea to the periphery. From this framework we get a simple rule for predicting fixation sequences: after each fixation, fixate next at the location that minimizes uncertainty (maximizes information) about the stimulus. By comparing our model performance to human eye movement data and to predictions from a saliency and random model, we demonstrate that our model is best at predicting fixation locations. Modeling additional biological constraints will improve the prediction of fixation sequences. Our results suggest that information maximization is a useful principle for programming eye movements.

  19. An ocular biomechanic model for dynamic simulation of different eye movements.

    PubMed

    Iskander, J; Hossny, M; Nahavandi, S; Del Porto, L

    2018-04-11

    Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biomechanic ocular models that are easily integrated into the available musculoskeletal models. The model was previously used to simulate eye-head coordination. The models are used to simulate and analyse eye movements. The proposed models are based on physiological and kinematic properties of the human eye. They incorporate an eye-globe, orbital suspension tissues and six muscles with their connective tissues (pulleys). Pulleys were incorporated in rectus and inferior oblique muscles. The two proposed models are the passive pulleys and the active pulleys models. Dynamic simulations of different eye movements, including fixation, saccade and smooth pursuit, are performed to validate both models. The resultant force-length curves of the models were similar to the experimental data. The simulation results show that the proposed models are suitable to generate eye movement simulations with results comparable to other musculoskeletal models. The maximum kinematic root mean square error (RMSE) is 5.68° and 4.35° for the passive and active pulley models, respectively. The analysis of the muscle forces showed realistic muscle activation with increased muscle synergy in the active pulley model. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    PubMed

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  1. Digital image analysis: improving accuracy and reproducibility of radiographic measurement.

    PubMed

    Bould, M; Barnard, S; Learmonth, I D; Cunningham, J L; Hardy, J R

    1999-07-01

    To assess the accuracy and reproducibility of a digital image analyser and the human eye, in measuring radiographic dimensions. We experimentally compared radiographic measurement using either an image analyser system or the human eye with digital caliper. The assessment of total hip arthroplasty wear from radiographs relies on both the accuracy of radiographic images and the accuracy of radiographic measurement. Radiographs were taken of a slip gauge (30+/-0.00036 mm) and slip gauge with a femoral stem. The projected dimensions of the radiographic images were calculated by trigonometry. The radiographic dimensions were then measured by blinded observers using both techniques. For a single radiograph, the human eye was accurate to 0.26 mm and reproducible to +/-0.1 mm. In comparison the digital image analyser system was accurate to 0.01 mm with a reproducibility of +/-0.08 mm. In an arthroplasty model, where the dimensions of an object were corrected for magnification by the known dimensions of a femoral head, the human eye was accurate to 0.19 mm, whereas the image analyser system was accurate to 0.04 mm. The digital image analysis system is up to 20 times more accurate than the human eye, and in an arthroplasty model the accuracy of measurement increases four-fold. We believe such image analysis may allow more accurate and reproducible measurement of wear from standard follow-up radiographs.

  2. Numerical modeling of heat and mass transfer in the human eye under millimeter wave exposure.

    PubMed

    Karampatzakis, Andreas; Samaras, Theodoros

    2013-05-01

    Human exposure to millimeter wave (MMW) radiation is expected to increase in the next several years. In this work, we present a thermal model of the human eye under MMW illumination. The model takes into account the fluid dynamics of the aqueous humor and predicts a frequency-dependent reversal of its flow that also depends on the incident power density. The calculated maximum fluid velocity in the anterior chamber and the temperature rise at the corneal apex are reported for frequencies from 40 to 100 GHz and different values of incident power density. Copyright © 2013 Wiley Periodicals, Inc.

  3. Reconstruction of the optical system of personalized eye models by using magnetic resonance imaging.

    PubMed

    Sun, Han-Yin; Lee, Chi-Hung; Chuang, Chun-Chao

    2016-11-10

    This study presents a practical method for reconstructing the optical system of personalized eye models by using magnetic resonance imaging (MRI). Monocular images were obtained from a young (20-year-old) healthy subject viewing at a near point (10 cm). Each magnetic resonance image was first analyzed using several commercial software to capture the profile of each optical element of the human eye except for the anterior lens surface, which could not be determined because it overlapped the ciliary muscle. The missing profile was substituted with a modified profile from a generic eye model. After the data-including the refractive indices from a generic model-were input in ZEMAX, we obtained a reasonable initial layout. By further considering the resolution of the MRI, the model was optimized to match the optical performance of a healthy eye. The main benefit of having a personalized eye model is the ability to quantitatively identify wide-angle ocular aberrations, which were corrected by the designed free-form spectacle lens.

  4. Eye Tracking Based Control System for Natural Human-Computer Interaction

    PubMed Central

    Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design. PMID:29403528

  5. Eye Tracking Based Control System for Natural Human-Computer Interaction.

    PubMed

    Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  6. Optical aberrations, retinal image quality and eye growth: Experimentation and modeling

    NASA Astrophysics Data System (ADS)

    Tian, Yibin

    2007-12-01

    Retinal image quality is important for normal eye growth. Optical aberrations are of interest for two reasons: first, they degrade retinal images; second, they might provide some cues to defocus. Higher than normal ocular aberrations have been previously associated with human myopia. However, these studies were cross-sectional in design, and only reported aberrations in terms of root mean square (RMS) errors of Zernike coefficients, a poor metric of optical quality. This dissertation presents results from investigations of ocular optical aberrations, retinal image quality and eye growth in chicks and humans. A number of techniques were utilized, including Shack-Hartmann aberrometry, high-frequency A-scan ultrasonography, ciliary nerve section (CNX), photorefractive keratectomy (PRK) as well as computer simulations and modeling. A technique to extract light scatter information from Shack-Hartmann images was also developed. The main findings of the dissertation are summarized below. In young chicks, most ocular aberrations decreased with growth in both normal and CNX eyes, and there were diurnal fluctuations in some aberrations. Modeling suggested active reduction in higher order aberrations (HOAs) during early development. Although CNX eyes manifested greater than normal HOAs, they showed near normal growth. Retinal image degradation varied greatly among individual eyes post-PRK in young chicks. Including light scatter information into analyses of retinal image quality better estimated the latter. Albino eyes showed more severe retinal image degradation than normal eyes, due to increased optical aberrations and light scatter, but their growth was similar to those of normal eyes, implying that they are relatively insensitive to retina image quality. Although the above results questioned the influence of optical aberrations on early ocular growth, some optical quality metrics, derived from optical aberrations data, could predict how much the eyes of young chicks subsequently elongated. The performance of some focus measures was very poor when non-defocus aberrations exceeded a certain level; presumably, these non-defocus aberrations might interfere with the eye's ability to interpret defocus. In anisomyopic human adults, more myopic eyes had larger anterior and vitreous chambers, greater astigmatism, and more positive spherical aberration. However, compared to isometropes, only interocular differences in spherical equivalent refractive errors were significantly increased.

  7. Sensing Passive Eye Response to Impact Induced Head Acceleration Using MEMS IMUs.

    PubMed

    Meng, Yuan; Bottenfield, Brent; Bolding, Mark; Liu, Lei; Adams, Mark L

    2018-02-01

    The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.

  8. 2015 Summer Series - Lee Stone - Brain Function Through the Eyes of the Beholder

    NASA Image and Video Library

    2015-06-09

    The Visuomotor Control Laboratory (VCL) at NASA Ames conducts neuroscience research on the link between eye movements and brain function to provide an efficient and quantitative means of monitoring human perceptual performance. The VCL aims to make dramatic improvements in mission success through analysis, experimentation, and modeling of human performance and human-automation interaction. Dr. Lee Stone elaborates on how this research is conducted and how it contributes to NASA's mission and advances human-centered design and operations of complex aerospace systems.

  9. Eye-head coordination during free exploration in human and cat.

    PubMed

    Einhäuser, Wolfgang; Moeller, Gudrun U; Schumann, Frank; Conradt, Jörg; Vockeroth, Johannes; Bartl, Klaus; Schneider, Erich; König, Peter

    2009-05-01

    Eye, head, and body movements jointly control the direction of gaze and the stability of retinal images in most mammalian species. The contribution of the individual movement components, however, will largely depend on the ecological niche the animal occupies and the layout of the animal's retina, in particular its photoreceptor density distribution. Here the relative contribution of eye-in-head and head-in-world movements in cats is measured, and the results are compared to recent human data. For the cat, a lightweight custom-made head-mounted video setup was used (CatCam). Human data were acquired with the novel EyeSeeCam device, which measures eye position to control a gaze-contingent camera in real time. For both species, analysis was based on simultaneous recordings of eye and head movements during free exploration of a natural environment. Despite the substantial differences in ecological niche, photoreceptor density, and saccade frequency, eye-movement characteristics in both species are remarkably similar. Coordinated eye and head movements dominate the dynamics of the retinal input. Interestingly, compensatory (gaze-stabilizing) movements play a more dominant role in humans than they do in cats. This finding was interpreted to be a consequence of substantially different timescales for head movements, with cats' head movements showing about a 5-fold faster dynamics than humans. For both species, models and laboratory experiments therefore need to account for this rich input dynamic to obtain validity for ecologically realistic settings.

  10. The effect of human image in B2C website design: an eye-tracking study

    NASA Astrophysics Data System (ADS)

    Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo

    2014-09-01

    On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.

  11. An Emphasis on Perception: Teaching Image Formation Using a Mechanistic Model of Vision.

    ERIC Educational Resources Information Center

    Allen, Sue; And Others

    An effective way to teach the concept of image is to give students a model of human vision which incorporates a simple mechanism of depth perception. In this study two almost identical versions of a curriculum in geometrical optics were created. One used a mechanistic, interpretive eye model, and in the other the eye was modeled as a passive,…

  12. Diabetes-associated dry eye syndrome in a new humanized transgenic model of type 1 diabetes.

    PubMed

    Imam, Shahnawaz; Elagin, Raya B; Jaume, Juan Carlos

    2013-01-01

    Patients with Type 1 Diabetes (T1D) are at high risk of developing lacrimal gland dysfunction. We have developed a new model of human T1D using double-transgenic mice carrying HLA-DQ8 diabetes-susceptibility haplotype instead of mouse MHC-class II and expressing the human beta cell autoantigen Glutamic Acid Decarboxylase in pancreatic beta cells. We report here the development of dry eye syndrome (DES) after diabetes induction in our humanized transgenic model. Double-transgenic mice were immunized with DNA encoding human GAD65, either naked or in adenoviral vectors, to induce T1D. Mice monitored for development of diabetes developed lacrimal gland dysfunction. Animals developed lacrimal gland disease (classically associated with diabetes in Non Obese Diabetic [NOD] mice and with T1D in humans) as they developed glucose intolerance and diabetes. Animals manifested obvious clinical signs of dry eye syndrome (DES), from corneal erosions to severe keratitis. Histological studies of peri-bulbar areas revealed lymphocytic infiltration of glandular structures. Indeed, infiltrative lesions were observed in lacrimal/Harderian glands within weeks following development of glucose intolerance. Lesions ranged from focal lymphocytic infiltration to complete acinar destruction. We observed a correlation between the severity of the pancreatic infiltration and the severity of the ocular disease. Our results demonstrate development of DES in association with antigen-specific insulitis and diabetes following immunization with clinically relevant human autoantigen concomitantly expressed in pancreatic beta cells of diabetes-susceptible mice. As in the NOD mouse model and as in human T1D, our animals developed diabetes-associated DES. This specific finding stresses the relevance of our model for studying these human diseases. We believe our model will facilitate studies to prevent/treat diabetes-associated DES as well as human diabetes.

  13. Design and Validation of an Infrared Badal Optometer for Laser Speckle (IBOLS)

    PubMed Central

    Teel, Danielle F. W.; Copland, R. James; Jacobs, Robert J.; Wells, Thad; Neal, Daniel R.; Thibos, Larry N.

    2009-01-01

    Purpose To validate the design of an infrared wavefront aberrometer with a Badal optometer employing the principle of laser speckle generated by a spinning disk and infrared light. The instrument was designed for subjective meridional refraction in infrared light by human patients. Methods Validation employed a model eye with known refractive error determined with an objective infrared wavefront aberrometer. The model eye was used to produce a speckle pattern on an artificial retina with controlled amounts of ametropia introduced with auxiliary ophthalmic lenses. A human observer performed the psychophysical task of observing the speckle pattern (with the aid of a video camera sensitive to infrared radiation) formed on the artificial retina. Refraction was performed by adjusting the vergence of incident light with the Badal optometer to nullify the motion of laser speckle. Validation of the method was performed for different levels of spherical ametropia and for various configurations of an astigmatic model eye. Results Subjective measurements of meridional refractive error over the range −4D to + 4D agreed with astigmatic refractive errors predicted by the power of the model eye in the meridian of motion of the spinning disk. Conclusions Use of a Badal optometer to control laser speckle is a valid method for determining subjective refractive error at infrared wavelengths. Such an instrument will be useful for comparing objective measures of refractive error obtained for the human eye with autorefractors and wavefront aberrometers that employ infrared radiation. PMID:18772719

  14. Motion-adaptive model-assisted compatible coding with spatiotemporal scalability

    NASA Astrophysics Data System (ADS)

    Lee, JaeBeom; Eleftheriadis, Alexandros

    1997-01-01

    We introduce the concept of motion adaptive spatio-temporal model-assisted compatible (MA-STMAC) coding, a technique to selectively encode areas of different importance to the human eye in terms of space and time in moving images with the consideration of object motion. PRevious STMAC was proposed base don the fact that human 'eye contact' and 'lip synchronization' are very important in person-to-person communication. Several areas including the eyes and lips need different types of quality, since different areas have different perceptual significance to human observers. The approach provides a better rate-distortion tradeoff than conventional image coding techniques base don MPEG-1, MPEG- 2, H.261, as well as H.263. STMAC coding is applied on top of an encoder, taking full advantage of its core design. Model motion tracking in our previous STMAC approach was not automatic. The proposed MA-STMAC coding considers the motion of the human face within the STMAC concept using automatic area detection. Experimental results are given using ITU-T H.263, addressing very low bit-rate compression.

  15. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry

    NASA Astrophysics Data System (ADS)

    Caracappa, Peter F.; Rhodes, Ashley; Fiedler, Derek

    2014-09-01

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  16. A Simple Model of the Accommodating Lens of the Human Eye

    ERIC Educational Resources Information Center

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  17. Tear film dynamics with evaporation, wetting, and time-dependent flux boundary condition on an eye-shaped domain

    PubMed Central

    Li, Longfei; Braun, R. J.; Maki, K. L.; Henshaw, W. D.; King-Smith, P. E.

    2014-01-01

    We study tear film dynamics with evaporation on a wettable eye-shaped ocular surface using a lubrication model. The mathematical model has a time-dependent flux boundary condition that models the cycles of tear fluid supply and drainage; it mimics blinks on a stationary eye-shaped domain. We generate computational grids and solve the nonlinear governing equations using the OVERTURE computational framework. In vivo experimental results using fluorescent imaging are used to visualize the influx and redistribution of tears for an open eye. Results from the numerical simulations are compared with the experiment. The model captures the flow around the meniscus and other dynamic features of human tear film observed in vivo. PMID:24926191

  18. Skin and Eye Irritation Assessment of Oil Palm ( Elaeis guineensis) Leaf Extract for Topical Application.

    PubMed

    Yusof, Nor Zuliana; Abd Gani, Siti Salwa; Azizul Hasan, Zafarizal Aldrin; Idris, Zainab

    2018-01-01

    Many types of phytochemicals have been found to be present in oil palm leaf and could potentially be used as functional ingredients for skincare product. However, as of today, there is no published report on hazard identification and safety assessment of oil palm ( Elaeis guineensis) leaf extract (OPLE), particularly on skin and eye irritation. In this study, potential hazard of OPLE on skin and eye irritation was evaluated as an initial step to the safety assessment of OPLE. In vitro cell viability study of OPLE on normal human dermal fibroblasts showed that OPLE was nontoxic to the cells with percentage viability more than 90% after 24 and 48 hours of incubation. Skin irritation potential of OPLE was evaluated using in vitro SkinEthic reconstructed human epidermis (RHE) model (Organization for Economic Cooperation and Development [OECD] Test Guideline 439, 2015), while eye irritation potential was evaluated using in vitro SkinEthic Human corneal epithelium (HCE) model (OECD test guideline 492, 2017). Hazard identification results showed that OPLE at 1%, 5%, and 10% (wt/wt) was classified as nonirritant to the skin and eye where mean tissue viabilities of SkinEthic RHE and SkinEthic HCE were more than 50% and 60%, respectively. Therefore, we recommend a further safety assessment, such as human patch testing, to confirm the nonirritant of OPLE.

  19. Development of a human eye model incorporated with intraocular scattering for visual performance assessment

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng

    2012-07-01

    A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.

  20. The effects of metamaterial on electromagnetic fields absorption characteristics of human eye tissues.

    PubMed

    Gasmelseed, Akram; Yunus, Jasmy

    2014-01-01

    The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Digital Quantification of Human Eye Color Highlights Genetic Association of Three New Loci

    PubMed Central

    Liu, Fan; Wollstein, Andreas; Hysi, Pirro G.; Ankra-Badu, Georgina A.; Spector, Timothy D.; Park, Daniel; Zhu, Gu; Larsson, Mats; Duffy, David L.; Montgomery, Grant W.; Mackey, David A.; Walsh, Susan; Lao, Oscar; Hofman, Albert; Rivadeneira, Fernando; Vingerling, Johannes R.; Uitterlinden, André G.; Martin, Nicholas G.; Hammond, Christopher J.; Kayser, Manfred

    2010-01-01

    Previous studies have successfully identified genetic variants in several genes associated with human iris (eye) color; however, they all used simplified categorical trait information. Here, we quantified continuous eye color variation into hue and saturation values using high-resolution digital full-eye photographs and conducted a genome-wide association study on 5,951 Dutch Europeans from the Rotterdam Study. Three new regions, 1q42.3, 17q25.3, and 21q22.13, were highlighted meeting the criterion for genome-wide statistically significant association. The latter two loci were replicated in 2,261 individuals from the UK and in 1,282 from Australia. The LYST gene at 1q42.3 and the DSCR9 gene at 21q22.13 serve as promising functional candidates. A model for predicting quantitative eye colors explained over 50% of trait variance in the Rotterdam Study. Over all our data exemplify that fine phenotyping is a useful strategy for finding genes involved in human complex traits. PMID:20463881

  2. Effect of human milk as a treatment for dry eye syndrome in a mouse model

    PubMed Central

    Diego, Jose L.; Bidikov, Luke; Pedler, Michelle G.; Kennedy, Jeffrey B.; Quiroz-Mercado, Hugo; Gregory, Darren G.; Petrash, J. Mark

    2016-01-01

    Purpose Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies’ efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. Methods The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Results Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to increase in eyes treated with nopal-derived materials. Conclusions Whole and fat-reduced human milk showed promising effects in the prevention of BAK-induced loss of corneal epithelial thickness and epithelial damage in this mouse model. Further studies are required to determine whether human milk may be safely used to treat dry eye in patients. PMID:27667918

  3. Effect of human milk as a treatment for dry eye syndrome in a mouse model.

    PubMed

    Diego, Jose L; Bidikov, Luke; Pedler, Michelle G; Kennedy, Jeffrey B; Quiroz-Mercado, Hugo; Gregory, Darren G; Petrash, J Mark; McCourt, Emily A

    Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies' efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to increase in eyes treated with nopal-derived materials. Whole and fat-reduced human milk showed promising effects in the prevention of BAK-induced loss of corneal epithelial thickness and epithelial damage in this mouse model. Further studies are required to determine whether human milk may be safely used to treat dry eye in patients.

  4. Seeing the future: using Xenopus to understand eye regeneration.

    PubMed

    Tseng, Ai-Sun

    2017-01-01

    Studies of Xenopus eye development have contributed considerably to the understanding of vertebrate neurogenesis, including eye field specification, cell fate determination and identification of genes critical for eye formation. This knowledge has served as a solid foundation for cellular and molecular examinations of the robust regenerative capacity of the Xenopus eye. The retina, lens, and the optic nerve are capable of regeneration after injury in both larval and adult stages. Here, we discuss the current models for studying eye regeneration in Xenopus and their potential applications for providing insights into human eye diseases. As Xenopus has many of the same tools that are available for other regeneration models, we thus highlight the distinct strengths and versatility of this organism that make it especially suited for extrapolating and testing strategies aimed at promoting regeneration and repair in eye tissues. Furthermore, we outline a promising future for the use of new techniques and approaches to address outstanding questions in understanding eye regeneration. © 2017 Wiley Periodicals, Inc.

  5. Optical eye simulator for laser dazzle events.

    PubMed

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.

  6. Indentation and needle insertion properties of the human eye

    PubMed Central

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-01-01

    Purpose Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. Methods An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. Results The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (P<0.001). Needle insertion through the anterior sclera (adjacent to the limbus) and posterior sclera (adjacent to the optic nerve) required the greatest amount of force (0.954 and 1.005 N, respectively). The force required to penetrate the central cornea (0.518 N) was significantly lower than all other areas except the midline sclera (0.700 N) Conclusion These data form the basis for further research into the development of a tissue-mimicking human eye construct with potential utility as a model for use in ophthalmology research and surgical teaching. PMID:24810571

  7. Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes

    PubMed Central

    Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.

    2016-01-01

    Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614

  8. Anticipatory Eye Movements in Interleaving Templates of Human Behavior

    NASA Technical Reports Server (NTRS)

    Matessa, Michael

    2004-01-01

    Performance modeling has been made easier by architectures which package psychological theory for reuse at useful levels of abstraction. CPM-GOMS uses templates of behavior to package at a task level (e.g., mouse move-click, typing) predictions of lower-level cognitive, perceptual, and motor resource use. CPM-GOMS also has a theory for interleaving resource use between templates. One example of interleaving is anticipatory eye movements. This paper describes the use of ACT-Stitch, a framework for translating CPM-GOMS templates and interleaving theory into ACT-R, to model anticipatory eye movements in skilled behavior. The anticipatory eye movements explain performance in a well-practiced perceptual/motor task, and the interleaving theory is supported with results from an eye-tracking experiment.

  9. Staining and peeling of the internal limiting membrane in the cat eye.

    PubMed

    Gandorfer, Arnd; Rohleder, Matthias; Charteris, David G; Sethi, Charanjit; Kampik, Anselm; Luthert, Philip

    2005-11-01

    To investigate the cat vitreomacular interface using trypan blue (TB) and indocyanine green (ICG) and to determine the validity of the cat model in terms of staining and peeling of the internal limiting membrane (ILM). Lensectomy and vitrectomy were performed in four eyes of two cats. The ILM of two eyes was stained with TB (0.15%). ILM peeling was performed in one eye. Two eyes were stained with ICG (0.5%). One eye was illuminated for 3 min. Light and transmission electron microscopy and confocal microscopy were performed. Clinically, both dyes stained the cat ILM similar to human ILM. TB staining resulted in a normal ultrastructure and antigenity of the retina. ILM peeling was associated with intraretinal bleeding. There were fragments of Müller cells adherent to the retinal side of the ILM, and Müller cell endfeet were ruptured and avulsed. ICG staining of the ILM followed by illumination caused severe inner retinal damage. ICG without illumination resulted in focal ILM detachments associated with tearing of Müller cell endfeet. The cat can be used as a model to study the effect of TB and ICG on the central area of the cat retina, as previous results from clinical and experimental postmortem settings in human eyes were confirmed in the current study. Peeling of the ILM as a sheet as performed in human macular surgery is not feasible. Differences in the ultrastructure of the ILM and a strong adhesion of the ILM to Müller cell endfeet may account for this observation.

  10. Protective ocular mechanisms in woodpeckers.

    PubMed

    Wygnanski-Jaffe, T; Murphy, C J; Smith, C; Kubai, M; Christopherson, P; Ethier, C R; Levin, A V

    2007-01-01

    Woodpeckers possess mechanisms protecting the eye from shaking/impact. Mechanisms available to woodpeckers but not humans may help explain some eye injuries in Shaken Baby syndrome (SBS). Gross dissection and histologic examination of eyes and orbits of seven woodpeckers. All birds showed restricted axial globe movement due to the tight fit within the orbit and fascial connections between the orbital rim and sclera. The sclera was reinforced with cartilage and bone, the optic nerve lacked redundancy, and the vitreous lacked attachments to the posterior pole retina. Woodpecker eyes differ from human infants by an inability of the globe to move axially in the orbit, the sclera to deform, and the vitreous to shear the retina. These findings support current hypotheses that abusive acceleration-deceleration-induced ocular injury in human infants may be related to translation of vitreous within the globe and the globe within the orbit. The woodpecker presents a natural model resistant to mechanical forces that have some similarity to SBS.

  11. Fast hierarchical knowledge-based approach for human face detection in color images

    NASA Astrophysics Data System (ADS)

    Jiang, Jun; Gong, Jie; Zhang, Guilin; Hu, Ruolan

    2001-09-01

    This paper presents a fast hierarchical knowledge-based approach for automatically detecting multi-scale upright faces in still color images. The approach consists of three levels. At the highest level, skin-like regions are determinated by skin model, which is based on the color attributes hue and saturation in HSV color space, as well color attributes red and green in normalized color space. In level 2, a new eye model is devised to select human face candidates in segmented skin-like regions. An important feature of the eye model is that it is independent of the scale of human face. So it is possible for finding human faces in different scale with scanning image only once, and it leads to reduction the computation time of face detection greatly. In level 3, a human face mosaic image model, which is consistent with physical structure features of human face well, is applied to judge whether there are face detects in human face candidate regions. This model includes edge and gray rules. Experiment results show that the approach has high robustness and fast speed. It has wide application perspective at human-computer interactions and visual telephone etc.

  12. A Transgenic Drosophila melanogaster Model To Study Human T-Lymphotropic Virus Oncoprotein Tax-1-Driven Transformation In Vivo

    PubMed Central

    Shirinian, Margret; Kambris, Zakaria; Hamadeh, Lama; Grabbe, Caroline; Journo, Chloé; Mahieux, Renaud

    2015-01-01

    Human T-cell lymphotropic virus type 1 (HTLV-1)-induced adult T-cell leukemia/lymphoma is an aggressive malignancy. HTLV-2 is genetically related to HTLV-1 but does not cause any malignant disease. HTLV-1 Tax transactivator (Tax-1) contributes to leukemogenesis via NF-κB. We describe transgenic Drosophila models expressing Tax in the compound eye and plasmatocytes. We demonstrate that Tax-1 but not Tax-2 induces ommatidial perturbation and increased plasmatocyte proliferation and that the eye phenotype is dependent on Kenny (IKKγ/NEMO), thus validating this new in vivo model. PMID:25995252

  13. Mechanistic-based non-animal assessment of eye toxicity: Inflammatory profile of human keratinocytes cells after exposure to eye damage/irritant agents.

    PubMed

    da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos

    2018-06-25

    Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential. Copyright © 2018. Published by Elsevier B.V.

  14. Preparation of Nonhuman Primate Eyes for Histological Evaluation After Retinal Gene Transfer.

    PubMed

    Bell, Peter; Yu, Hongwei; Kuntz, Leah; Ahonkhai, Omua; Tretiakova, Anna; Limberis, Maria P; Wilson, James M

    2018-06-01

    To evaluate gene therapy for retinal disorders, appropriate models of the human eye are needed. Nonhuman primate eyes offer significant advantages over rodent eyes. However, current preparation methods have limitations. Here, a protocol is described for histological processing of nonhuman primate eyes after gene transfer. The user dissects unfixed eyes, flattens the globe parts within filter paper, and performs formalin fixation and paraffin embedding. This method obviates the need for harsh fixatives, allowing subsequent immunostaining or in situ hybridization while preserving tissue integrity for histopathological evaluation. Moreover, the straight orientation of the retinal cell layers is ideal for image analysis.

  15. Successful gene therapy in the RPGRIP1-deficient dog: a large model of cone-rod dystrophy.

    PubMed

    Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne

    2014-02-01

    For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod-cone dystrophies but not in large models of progressive cone-rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone-rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18-72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22-29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone-rod dystrophy provides great promise for human treatment.

  16. Ray tracing for inhomogeneous media applied to the human eye

    NASA Astrophysics Data System (ADS)

    Diaz-Gonzalez, G.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.

    2017-08-01

    Inhomogeneous or gradient index media exhibit a refractive index varying with the position. This kind of media are very interesting because they can be found in both synthetic as well as real life optical devices such as the human lens. In this work we present the development of a computational tool for ray tracing in refractive optical systems. Particularly, the human eye is used as the optical system under study. An inhomogeneous medium with similar characteristics to the human lens is introduced and modeled by the so-called slices method. The useful of our proposal is illustrated by several graphical results.

  17. Design of optical system for binocular fundus camera.

    PubMed

    Wu, Jun; Lou, Shiliang; Xiao, Zhitao; Geng, Lei; Zhang, Fang; Wang, Wen; Liu, Mengjia

    2017-12-01

    A non-mydriasis optical system for binocular fundus camera has been designed in this paper. It can capture two images of the same fundus retinal region from different angles at the same time, and can be used to achieve three-dimensional reconstruction of fundus. It is composed of imaging system and illumination system. In imaging system, Gullstrand Le Grand eye model is used to simulate normal human eye, and Schematic eye model is used to test the influence of ametropia in human eye on imaging quality. Annular aperture and black dot board are added into illumination system, so that the illumination system can eliminate stray light produced by corneal-reflected light and omentoscopic lens. Simulation results show that MTF of each visual field at the cut-off frequency of 90lp/mm is greater than 0.2, system distortion value is -2.7%, field curvature is less than 0.1 mm, radius of Airy disc is 3.25um. This system has a strong ability of chromatic aberration correction and focusing, and can image clearly for human fundus in which the range of diopters is from -10 D to +6 D(1 D = 1 m -1 ).

  18. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    PubMed

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  19. Full ocular biometry through dual-depth whole-eye optical coherence tomography

    PubMed Central

    Kim, Hyung-Jin; Kim, Minji; Hyeon, Min Gyu; Choi, Youngwoon; Kim, Beop-Min

    2018-01-01

    We propose a new method of determining the optical axis (OA), pupillary axis (PA), and visual axis (VA) of the human eye by using dual-depth whole-eye optical coherence tomography (OCT). These axes, as well as the angles “α” between the OA and VA and “κ” between PA and VA, are important in many ophthalmologic applications, especially in refractive surgery. Whole-eye images are reconstructed based on simultaneously acquired images of the anterior segment and retina. The light from a light source is split into two orthogonal polarization components for imaging the anterior segment and retina, respectively. The OA and PA are identified based on their geometric definitions by using the anterior segment image only, while the VA is detected through accurate correlation between the two images. The feasibility of our approach was tested using a model eye and human subjects. PMID:29552378

  20. Human eye haptics-based multimedia.

    PubMed

    Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2014-01-01

    Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.

  1. The Physics of Colour Vision.

    ERIC Educational Resources Information Center

    Goldman, Martin

    1985-01-01

    An elementary physical model of cone receptor cells is explained and applied to complexities of human color vision. One-, two-, and three-receptor systems are considered, with the later shown to be the best model for the human eye. Color blindness is also discussed. (DH)

  2. Dose conversion coefficients for photon exposure of the human eye lens.

    PubMed

    Behrens, R; Dietze, G

    2011-01-21

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  3. Human lamina cribrosa insertion and age.

    PubMed

    Sigal, Ian A; Flanagan, John G; Lathrop, Kira L; Tertinegg, Inka; Bilonick, Richard

    2012-10-03

    To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%-29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44-0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further.

  4. Human Lamina Cribrosa Insertion and Age

    PubMed Central

    Sigal, Ian A.; Flanagan, John G.; Lathrop, Kira L.; Tertinegg, Inka; Bilonick, Richard

    2012-01-01

    Purpose. To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. Methods. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. Results. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%–29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44–0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. Conclusions. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further. PMID:22956611

  5. A new mapping function in table-mounted eye tracker

    NASA Astrophysics Data System (ADS)

    Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.

  6. Protective effects of carbenoxolone, an 11β-HSD1 inhibitor, against chemical induced dry eye syndrome.

    PubMed

    Na, Yoon-Ju; Choi, Kyoung-Jin; Park, Sung Bum; Sung, Hye-Rim; Jung, Won Hoon; Kim, Hee Youn; Rhee, Sang Dal; Kim, Ki Young

    2017-11-01

    Dry eye syndrome (DES) is a disorder of the eye due to tear deficiency or excessive evaporation that causes damage to the eye and is associated with discomfort and dryness. 11β-Hydroxysteroid dehydrogenase 1 (11β-HSD1) is an enzyme that converts inactive cortisone to active cortisol. Recently, 11β-HSD1 has been expressed in human and rodent eyes and has been recognized as a target of glaucoma. In this study, the therapeutic effects and underlying mechanisms of topical carbenoxolone, an 11β-HSD1 inhibitor, were investigated in benzalkonium chloride (BAC)-treated human conjunctival epithelial cells and a rat DES model. In the in vitro study, carbenoxolone dose-dependently inhibited cell death and 11β-HSD1 activity in BAC-treated human conjunctival epithelial cells. For the in vivo study, carbenoxolone or a solvent was administered to the BAC-induced DES model twice daily. BAC-treated rat eyes showed significant increases in ocular surface damage, a reduction of tears, decrease corneal thickness, corneal basement membrane destruction, apoptosis in the conjunctival epithelium, and expression of pro-inflammatory cytokines (TNF-α and IL-6) and 11β-HSD1. These effects of BAC were reversed by topical carbenoxolone treatment. These results demonstrate that carbenoxolone can prevent DES by inhibiting pro-inflammatory cytokine expression and cell death of the corneal and conjunctival epithelium via inhibition of both 11β-HSD1 activity and expression in the eyes of BAC-treated rats. It is suggested that topical 11β-HSD1 inhibitors may provide a new therapeutic window in the prevention and/or treatment of DES.

  7. A Transgenic Drosophila melanogaster Model To Study Human T-Lymphotropic Virus Oncoprotein Tax-1-Driven Transformation In Vivo.

    PubMed

    Shirinian, Margret; Kambris, Zakaria; Hamadeh, Lama; Grabbe, Caroline; Journo, Chloé; Mahieux, Renaud; Bazarbachi, Ali

    2015-08-01

    Human T-cell lymphotropic virus type 1 (HTLV-1)-induced adult T-cell leukemia/lymphoma is an aggressive malignancy. HTLV-2 is genetically related to HTLV-1 but does not cause any malignant disease. HTLV-1 Tax transactivator (Tax-1) contributes to leukemogenesis via NF-κB. We describe transgenic Drosophila models expressing Tax in the compound eye and plasmatocytes. We demonstrate that Tax-1 but not Tax-2 induces ommatidial perturbation and increased plasmatocyte proliferation and that the eye phenotype is dependent on Kenny (IKKγ/NEMO), thus validating this new in vivo model. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  8. Etracker: A Mobile Gaze-Tracking System with Near-Eye Display Based on a Combined Gaze-Tracking Algorithm.

    PubMed

    Li, Bin; Fu, Hong; Wen, Desheng; Lo, WaiLun

    2018-05-19

    Eye tracking technology has become increasingly important for psychological analysis, medical diagnosis, driver assistance systems, and many other applications. Various gaze-tracking models have been established by previous researchers. However, there is currently no near-eye display system with accurate gaze-tracking performance and a convenient user experience. In this paper, we constructed a complete prototype of the mobile gaze-tracking system ' Etracker ' with a near-eye viewing device for human gaze tracking. We proposed a combined gaze-tracking algorithm. In this algorithm, the convolutional neural network is used to remove blinking images and predict coarse gaze position, and then a geometric model is defined for accurate human gaze tracking. Moreover, we proposed using the mean value of gazes to resolve pupil center changes caused by nystagmus in calibration algorithms, so that an individual user only needs to calibrate it the first time, which makes our system more convenient. The experiments on gaze data from 26 participants show that the eye center detection accuracy is 98% and Etracker can provide an average gaze accuracy of 0.53° at a rate of 30⁻60 Hz.

  9. A dataset of stereoscopic images and ground-truth disparity mimicking human fixations in peripersonal space

    PubMed Central

    Canessa, Andrea; Gibaldi, Agostino; Chessa, Manuela; Fato, Marco; Solari, Fabio; Sabatini, Silvio P.

    2017-01-01

    Binocular stereopsis is the ability of a visual system, belonging to a live being or a machine, to interpret the different visual information deriving from two eyes/cameras for depth perception. From this perspective, the ground-truth information about three-dimensional visual space, which is hardly available, is an ideal tool both for evaluating human performance and for benchmarking machine vision algorithms. In the present work, we implemented a rendering methodology in which the camera pose mimics realistic eye pose for a fixating observer, thus including convergent eye geometry and cyclotorsion. The virtual environment we developed relies on highly accurate 3D virtual models, and its full controllability allows us to obtain the stereoscopic pairs together with the ground-truth depth and camera pose information. We thus created a stereoscopic dataset: GENUA PESTO—GENoa hUman Active fixation database: PEripersonal space STereoscopic images and grOund truth disparity. The dataset aims to provide a unified framework useful for a number of problems relevant to human and computer vision, from scene exploration and eye movement studies to 3D scene reconstruction. PMID:28350382

  10. Modeling human vestibular responses during eccentric rotation and off vertical axis rotation

    NASA Technical Reports Server (NTRS)

    Merfeld, D. M.; Paloski, W. H. (Principal Investigator)

    1995-01-01

    A mathematical model has been developed to help explain human multi-sensory interactions. The most important constituent of the model is the hypothesis that the nervous system incorporates knowledge of sensory dynamics into an "internal model" of these dynamics. This internal model allows the nervous system to integrate the sensory information from many different sensors into a coherent estimate of self-motion. The essence of the model is unchanged from a previously published model of monkey eye movement responses; only a few variables have been adjusted to yield the prediction of human responses. During eccentric rotation, the model predicts that the axis of eye rotation shifts slightly toward alignment with gravito-inertial force. The model also predicts that the time course of the perception of tilt following the acceleration phase of eccentric rotation is much slower than that during deceleration. During off vertical axis rotation (OVAR) the model predicts a small horizontal bias along with small horizontal, vertical, and torsional oscillations. Following OVAR stimulation, when stopped right- or left-side down, a small vertical component is predicted that decays with the horizontal post-rotatory response. All of the predictions are consistent with measurements of human responses.

  11. Experimental characterization of the imaging properties of multifocal intraocular lenses

    NASA Astrophysics Data System (ADS)

    Gobbi, Pier Giorgio; Fasce, Francesco; Bozza, Stefano; Brancato, Rosario

    2003-07-01

    Many different types of intraocular lenses (IOL) are currently available for implantation, both as crystalline lens replacements and as phakic refractive elements. Their optical design is increasingly sophisticated, including aspherical surface profiles and multi-zone multifocal structures, however a quantitative and comparative characterization of their imaging properties is lacking. Also a qualitative visualization of their properties would be very useful for patients in the lens choice process. To this end an experimental eye model has been developed to allow for simulated in-vivo testing of IOLs. The model cornea is made of PMMA with a dioptric power of 43 D, and it has an aspherical profile designed to minimize spherical aberration across the visible spectrum. The eye model has a variable iris and a mechanical support to accomodate IOLs, immersed in physiological solution. The eye length is variable and the retina is replaced by a glass plate. The image formed on this "retina" is optically conjugated to a CCD camera, with a suitable magnification in order to mimic the human fovea resolution, and displayed onto a monitor. With such an opto-mechanical eye model, two types of images have been used to characterize IOLs: letter charts and variable contrast gratings, in order to directly simulate human visual acuity and contrast sensitivity.

  12. Diffractive-optical correlators: chances to make optical image preprocessing as intelligent as human vision

    NASA Astrophysics Data System (ADS)

    Lauinger, Norbert

    2004-10-01

    The human eye is a good model for the engineering of optical correlators. Three prominent intelligent functionalities in human vision could in the near future become realized by a new diffractive-optical hardware design of optical imaging sensors: (1) Illuminant-adaptive RGB-based color Vision, (2) Monocular 3D Vision based on RGB data processing, (3) Patchwise fourier-optical Object-Classification and Identification. The hardware design of the human eye has specific diffractive-optical elements (DOE's) in aperture and in image space and seems to execute the three jobs at -- or not far behind -- the loci of the images of objects.

  13. Working sketch of an anatomically and optically equivalent physical model eye

    NASA Astrophysics Data System (ADS)

    Bakaraju, Ravi Chandra; Ehrmann, Klaus; Falk, Darrin; Papas, Eric B.; Ho, Arthur

    2009-02-01

    Our aim was to fabricate a bench-top physical model eye that closely replicates anatomical and optical properties of the average human eye, and to calibrate and standardize this model to suit normal viewing conditions and subsequently utilize it to understand the optical performance of corrective lens designs; especially multifocal soft contact lenses. Using available normative data on ocular biometrics and Zemax ray-tracing software as a tool, we modeled 25, 45 and 55 year-old average adult human eyes with discrete accommodation levels and pupil sizes. Specifications for the components were established following manufacturing tolerance analyses. The cornea was lathed from an optical material with refractive index of 1.376 @ 589 nm and the crystalline lenses were made of Boston RGP polymers with refractive indices of 1.423 (45 & 55yr) and 1.429 (25yr) @ 589 nm. These two materials served to model the equivalent crystalline lens of the different age-groups. A camera, the acting retina, was hosted on the motor-base having translatory and rotary functions to facilitate the simulation of different states of ametropia and peripheral refraction respectively. We report on the implementation of the first prototype and present some simulations of the optical performance of certain contact lenses with specific levels of ametropia, to demonstrate the potential use of such a physical model eye. On completion of development, calibration and standardization, optical quality assessment and performance predictions of different ophthalmic lenses can be studied in great detail. Optical performance with corrective lenses may be reliably simulated and predicted by customized combined computational and physical models giving insight into the merits and pitfalls of their designs

  14. Gold nanoparticle‐based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye

    PubMed Central

    Vaez‐zadeh, Mehdi; Masoudi, S. Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S.

    2015-01-01

    The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry. PACS number: 87.53.Jw, 87.85.Rs, 87.10.Rt PMID:26699318

  15. Online Learners’ Reading Ability Detection Based on Eye-Tracking Sensors

    PubMed Central

    Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S. W.

    2016-01-01

    The detection of university online learners’ reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners’ pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner’s reading ability. PMID:27626418

  16. Successful Gene Therapy in the RPGRIP1-deficient Dog: a Large Model of Cone–Rod Dystrophy

    PubMed Central

    Lhériteau, Elsa; Petit, Lolita; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Libeau, Lyse; Mendes-Madeira, Alexandra; Guihal, Caroline; François, Achille; Guyon, Richard; Provost, Nathalie; Lemoine, Françoise; Papal, Samantha; El-Amraoui, Aziz; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne

    2014-01-01

    For the development of new therapies, proof-of-concept studies in large animal models that share clinical features with their human counterparts represent a pivotal step. For inherited retinal dystrophies primarily involving photoreceptor cells, the efficacy of gene therapy has been demonstrated in canine models of stationary cone dystrophies and progressive rod–cone dystrophies but not in large models of progressive cone–rod dystrophies, another important cause of blindness. To address the last issue, we evaluated gene therapy in the retinitis pigmentosa GTPase regulator interacting protein 1 (RPGRIP1)-deficient dog, a model exhibiting a severe cone–rod dystrophy similar to that seen in humans. Subretinal injection of AAV5 (n = 5) or AAV8 (n = 2) encoding the canine Rpgrip1 improved photoreceptor survival in transduced areas of treated retinas. Cone function was significantly and stably rescued in all treated eyes (18–72% of those recorded in normal eyes) up to 24 months postinjection. Rod function was also preserved (22–29% of baseline function) in four of the five treated dogs up to 24 months postinjection. No detectable rod function remained in untreated contralateral eyes. More importantly, treatment preserved bright- and dim-light vision. Efficacy of gene therapy in this large animal model of cone–rod dystrophy provides great promise for human treatment. PMID:24091916

  17. An Insect Eye Inspired Miniaturized Multi-Camera System for Endoscopic Imaging.

    PubMed

    Cogal, Omer; Leblebici, Yusuf

    2017-02-01

    In this work, we present a miniaturized high definition vision system inspired by insect eyes, with a distributed illumination method, which can work in dark environments for proximity imaging applications such as endoscopy. Our approach is based on modeling biological systems with off-the-shelf miniaturized cameras combined with digital circuit design for real time image processing. We built a 5 mm radius hemispherical compound eye, imaging a 180 ° ×180 ° degrees field of view while providing more than 1.1 megapixels (emulated ommatidias) as real-time video with an inter-ommatidial angle ∆ϕ = 0.5 ° at 18 mm radial distance. We made an FPGA implementation of the image processing system which is capable of generating 25 fps video with 1080 × 1080 pixel resolution at a 120 MHz processing clock frequency. When compared to similar size insect eye mimicking systems in literature, the system proposed in this paper features 1000 × resolution increase. To the best of our knowledge, this is the first time that a compound eye with built-in illumination idea is reported. We are offering our miniaturized imaging system for endoscopic applications like colonoscopy or laparoscopic surgery where there is a need for large field of view high definition imagery. For that purpose we tested our system inside a human colon model. We also present the resulting images and videos from the human colon model in this paper.

  18. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.

    PubMed

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-11

    In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.

  19. Characterisation of the porcine eyeball as an in-vitro model for dry eye.

    PubMed

    Menduni, Francesco; Davies, Leon N; Madrid-Costa, D; Fratini, Antonio; Wolffsohn, James S

    2018-02-01

    To characterise the anatomical parameters of the porcine eye for potentially using it as a laboratory model of dry eye. Anterior chamber depth and angle, corneal curvature, shortest and longest diameter, endothelial cell density, and pachymetry were measured in sixty freshly enucleated porcine eyeballs. Corneal steepest meridian was 7.85±0.32mm, corneal flattest meridian was 8.28±0.32mm, shortest corneal diameter was 12.69±0.58mm, longest corneal diameter was 14.88±0.66mm and central corneal ultrasonic pachymetry was 1009±1μm. Anterior chamber angle was 28.83±4.16°, anterior chamber depth was 1.77±0.27mm, and central corneal thickness measured using OCT was 1248±144μm. Corneal endothelial cell density was 3250±172 cells/mm 2 . Combining different clinical techniques produced a pool of reproducible data on the porcine eye anatomy, which can be used by researchers to assess the viability of using the porcine eye as an in-vitro/ex-vivo model for dry eye. Due to the similar morphology with the human eye, porcine eyeballs may represent a useful and cost effective model to individually study important key factors in the development of dry eye, such as environmental and mechanical stresses. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Dry Eye Disease and Microbial Keratitis: Is There a Connection?

    PubMed Central

    Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.

    2013-01-01

    Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043

  1. Optically inspired biomechanical model of the human eyeball.

    PubMed

    Sródka, Wieslaw; Iskander, D Robert

    2008-01-01

    Currently available biomechanical models of the human eyeball focus mainly on the geometries and material properties of its components while little attention has been given to its optics--the eye's primary function. We postulate that in the evolution process, the mechanical structure of the eyeball has been influenced by its optical functions. We develop a numerical finite element analysis-based model in which the eyeball geometry and its material properties are linked to the optical functions of the eye. This is achieved by controlling in the model all essential optical functions while still choosing material properties from a range of clinically available data. In particular, it is assumed that in a certain range of intraocular pressures, the eye is able to maintain focus. This so-called property of optical self-adjustments provides a more constrained set of numerical solutions in which the number of free model parameters significantly decreases, leading to models that are more robust. Further, we investigate two specific cases of a model that satisfies optical self-adjustment: (1) a full model in which the cornea is flexibly attached to sclera at the limbus, and (2) a fixed cornea model in which the cornea is not allowed to move at the limbus. We conclude that for a biomechanical model of the eyeball to mimic the optical function of a real eye, it is crucial that the cornea is allowed to move at the limbal junction, that the materials used for the cornea and sclera are strongly nonlinear, and that their moduli of elasticity remain in a very close relationship.

  2. Comparative Analysis of Gene Expression for Convergent Evolution of Camera Eye Between Octopus and Human

    PubMed Central

    Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi

    2004-01-01

    Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475

  3. Computing retinal contour from optical biometry.

    PubMed

    Faria-Ribeiro, Miguel; López-Gil, Norberto; Navarro, Rafael; Lopes-Ferreira, Daniela; Jorge, Jorge; González-Méijome, Jose Manuel

    2014-04-01

    To describe a new methodology that derives horizontal posterior retinal contours from partial coherence interferometry (PCI) and ray tracing using the corneal topography. Corneal topography and PCI for seven horizontal visual field eccentricities correspondent to the central 60 degrees of the posterior pole were obtained in 55 myopic eyes. A semicustomized eye model based on the subject's corneal topography and the Navarro eye model was generated using Zemax-EE software. The model was used to compute the optical path length in the seven directions where PCI measurements were obtained. Vitreous chamber depth was computed using the PCI values obtained at each of those directions. Matlab software was developed to fit the best conic curve to the set of points previously obtained. We tested the limit in the accuracy of the methodology when the actual cornea of the subject is not used and for two different lens geometries. A standard eye model can induce an error in the retina sagitta estimation of the order of hundreds of micrometers in comparison with the semicustomized eye model. However, the use of a different lens model leads to an error of the order of tens of micrometers. The apical radius and conic constant of the average fit were -11.91 mm and -0.15, respectively. In general, a nasal-temporal asymmetry in the retina contour was found, showing mean larger values of vitreous chamber depth in the nasal side of the eye. The use of a semicustomized eye model, together with optical path length measured by PCI for different angles, can be used to predict the retinal contour within tenths of micrometers. This methodology can be useful in studies trying to understand the effect of peripheral retinal location on myopia progression as well as modeling the optics of the human eye for a wide field.

  4. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  5. Rapid eye movements during sleep in mice: High trait-like stability qualifies rapid eye movement density for characterization of phenotypic variation in sleep patterns of rodents

    PubMed Central

    2011-01-01

    Background In humans, rapid eye movements (REM) density during REM sleep plays a prominent role in psychiatric diseases. Especially in depression, an increased REM density is a vulnerability marker for depression. In clinical practice and research measurement of REM density is highly standardized. In basic animal research, almost no tools are available to obtain and systematically evaluate eye movement data, although, this would create increased comparability between human and animal sleep studies. Methods We obtained standardized electroencephalographic (EEG), electromyographic (EMG) and electrooculographic (EOG) signals from freely behaving mice. EOG electrodes were bilaterally and chronically implanted with placement of the electrodes directly between the musculus rectus superior and musculus rectus lateralis. After recovery, EEG, EMG and EOG signals were obtained for four days. Subsequent to the implantation process, we developed and validated an Eye Movement scoring in Mice Algorithm (EMMA) to detect REM as singularities of the EOG signal, based on wavelet methodology. Results The distribution of wakefulness, non-REM (NREM) sleep and rapid eye movement (REM) sleep was typical of nocturnal rodents with small amounts of wakefulness and large amounts of NREM sleep during the light period and reversed proportions during the dark period. REM sleep was distributed correspondingly. REM density was significantly higher during REM sleep than NREM sleep. REM bursts were detected more often at the end of the dark period than the beginning of the light period. During REM sleep REM density showed an ultradian course, and during NREM sleep REM density peaked at the beginning of the dark period. Concerning individual eye movements, REM duration was longer and amplitude was lower during REM sleep than NREM sleep. The majority of single REM and REM bursts were associated with micro-arousals during NREM sleep, but not during REM sleep. Conclusions Sleep-stage specific distributions of REM in mice correspond to human REM density during sleep. REM density, now also assessable in animal models through our approach, is increased in humans after acute stress, during PTSD and in depression. This relationship can now be exploited to match animal models more closely to clinical situations, especially in animal models of depression. PMID:22047102

  6. Geometrical theory to predict eccentric photorefraction intensity profiles in the human eye

    NASA Astrophysics Data System (ADS)

    Roorda, Austin; Campbell, Melanie C. W.; Bobier, W. R.

    1995-08-01

    In eccentric photorefraction, light returning from the retina of the eye is photographed by a camera focused on the eye's pupil. We use a geometrical model of eccentric photorefraction to generate intensity profiles across the pupil image. The intensity profiles for three different monochromatic aberration functions induced in a single eye are predicted and show good agreement with the measured eccentric photorefraction intensity profiles. A directional reflection from the retina is incorporated into the calculation. Intensity profiles for symmetric and asymmetric aberrations are generated and measured. The latter profile shows a dependency on the source position and the meridian. The magnitude of the effect of thresholding on measured pattern extents is predicted. Monochromatic aberrations in human eyes will cause deviations in the eccentric photorefraction measurements from traditional crescents caused by defocus and may cause misdiagnoses of ametropia or anisometropia. Our results suggest that measuring refraction along the vertical meridian is preferred for screening studies with the eccentric photorefractor.

  7. The APO*E3-Leiden mouse as an animal model for basal laminar deposit

    PubMed Central

    Kliffen, M.; Lutgens, E.; Daemen, M.; de Muinck, E. D; Mooy, C.; de Jong, P. T V M

    2000-01-01

    AIM—To investigate the APO*E3-Leiden mouse as an animal model for age related maculopathy (ARM) related extracellular deposits.
METHODS—Eyes were obtained from APO*E3-Leiden transgenic mice on a high fat/cholesterol (HFC) diet (n=12) or on a normal mouse chow (n=6), for 9 months. As controls, eyes were collected from APO-E knockout mice on the same diets. From each mouse one eye was processed for microscopic evaluation and immunohistochemistry with a polyclonal antibody directed against human apo-E. Electron microscopy was also performed.
RESULTS—All 12 eyes of the APO*E3-Leiden mice on an HFC diet contained basal laminar deposit (BLD; class 1 to class 3), whereas two of six APO*E3-Leiden mice on normal chow showed BLD class 1. The ultrastructural aspects of this BLD were comparable with those seen in early BLD in humans, and BLD showed immunoreaction with anti-human-apo-E antibodies. No BLD was found in any of the control mice. Drusen were not detected in any of the mice.
CONCLUSION—These results indicate that APO*E3-Leiden mice can be used as animal model for the pathogenesis of BLD, and that a HFC diet enhances the accumulation of this deposit. Furthermore, this study supports the previously suggested involvement of dysfunctional apo-E in the accumulation of extracellular deposits in ARM.

 PMID:11090485

  8. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model.

    PubMed

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9(th) postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue.

  9. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model

    PubMed Central

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    AIM To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. METHODS We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9th postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. RESULTS Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). CONCLUSION In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue. PMID:26949638

  10. Getting Ahead of Oneself: Anticipation and the Vestibulo-ocular Reflex (VOR)

    PubMed Central

    King, W. Michael

    2014-01-01

    Compensatory counter-rotations of the eyes provoked by head turns are commonly attributed to the vestibulo-ocular reflex (VOR). A recent study in guinea pigs demonstrates, however, that this assumption is not always valid. During voluntary head turns, guinea pigs make highly accurate compensatory eye movements that occur with zero or even negative latencies with respect to the onset of the provoking head movements. Furthermore, the anticipatory eye movements occur in animals with bilateral peripheral vestibular lesions, thus confirming that they have an extra vestibular origin. This discovery suggests the possibility that anticipatory responses might also occur in other species including humans and non-human primates, but have been overlooked and mistakenly identified as being produced by the VOR. This review will compare primate and guinea pig vestibular physiology in light of these new findings. A unified model of vestibular and cerebellar pathways will be presented that is consistent with current data in primates and guinea pigs. The model is capable of accurately simulating compensatory eye movements to active head turns (anticipatory responses) and to passive head perturbations (VOR induced eye movements) in guinea pigs and in human subjects who use coordinated eye and head movements to shift gaze direction in space. Anticipatory responses provide new evidence and opportunities to study the role of extra vestibular signals in motor control and sensory-motor transformations. Exercises that employ voluntary head turns are frequently used to improve visual stability in patients with vestibular hypofunction. Thus, a deeper understanding of the origin and physiology of anticipatory responses could suggest new translational approaches to rehabilitative training of patients with bilateral vestibular loss. PMID:23370320

  11. Rotational symmetric HMD with eye-tracking capability

    NASA Astrophysics Data System (ADS)

    Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian

    2016-10-01

    As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.

  12. A standard model eye with micro scale multilayer structure for ophthalmic optical coherence tomography equipment

    NASA Astrophysics Data System (ADS)

    Cao, Zhenggang; Ding, Zengqian; Hu, Zhixiong; Wen, Tao; Qiao, Wen; Liu, Wenli

    2016-10-01

    Optical coherence tomography (OCT) has been widely applied in diagnosis of eye diseases during the last 20 years. Differing from traditional two-dimension imaging technologies, OCT could also provide cross-sectional information of target tissues simultaneously and precisely. As well known, axial resolution is one of the most critical parameters impacting the OCT image quality, which determines whether an accurate diagnosis could be obtained. Therefore, it is important to evaluate the axial resolution of an OCT equipment. Phantoms always play an important role in the standardization and validation process. Here, a standard model eye with micro-scale multilayer structure was custom designed and manufactured. Mimicking a real human eye, analyzing the physical characteristic of layer structures of retina and cornea in-depth, appropriate materials were selected by testing the scattering coefficient of PDMS phantoms with difference concentration of TiO2 or BaSO4 particles. An artificial retina and cornea with multilayer-films which have a thickness of 10 to 60 micrometers for each layer were fabricated using spin coating technology. Considering key parameters of the standard model eye need to be traceable as well as accurate, the optical refractive index and layer structure thicknesses of phantoms were verified by utilizing Thickness Monitoring System. Consequently, a standard OCT model eye was obtained after the retinal or corneal phantom was embedded into a water-filled model eye which has been fabricated by 3D printing technology to simulate ocular dispersion and emmetropic refraction. The eye model was manufactured with a transparent resin to simulate realistic ophthalmic testing environment, and most key optical elements including cornea, lens and vitreous body were realized. By investigating with a research and a clinical OCT system respectively, the OCT model eye was demonstrated with similar physical properties as natural eye, and the multilayer film measurement provided an effective method to rapidly evaluate the axial resolution of ophthalmic OCT devices.

  13. The Vestibular System and Human Dynamic Space Orientation

    NASA Technical Reports Server (NTRS)

    Meiry, J. L.

    1966-01-01

    The motion sensors of the vestibular system are studied to determine their role in human dynamic space orientation and manual vehicle control. The investigation yielded control models for the sensors, descriptions of the subsystems for eye stabilization, and demonstrations of the effects of motion cues on closed loop manual control. Experiments on the abilities of subjects to perceive a variety of linear motions provided data on the dynamic characteristics of the otoliths, the linear motion sensors. Angular acceleration threshold measurements supplemented knowledge of the semicircular canals, the angular motion sensors. Mathematical models are presented to describe the known control characteristics of the vestibular sensors, relating subjective perception of motion to objective motion of a vehicle. The vestibular system, the neck rotation proprioceptors and the visual system form part of the control system which maintains the eye stationary relative to a target or a reference. The contribution of each of these systems was identified through experiments involving head and body rotations about a vertical axis. Compensatory eye movements in response to neck rotation were demonstrated and their dynamic characteristics described by a lag-lead model. The eye motions attributable to neck rotations and vestibular stimulation obey superposition when both systems are active. Human operator compensatory tracking is investigated in simple vehicle orientation control system with stable and unstable controlled elements. Control of vehicle orientation to a reference is simulated in three modes: visual, motion and combined. Motion cues sensed by the vestibular system through tactile sensation enable the operator to generate more lead compensation than in fixed base simulation with only visual input. The tracking performance of the human in an unstable control system near the limits of controllability is shown to depend heavily upon the rate information provided by the vestibular sensors.

  14. Real time eye tracking using Kalman extended spatio-temporal context learning

    NASA Astrophysics Data System (ADS)

    Munir, Farzeen; Minhas, Fayyaz ul Amir Asfar; Jalil, Abdul; Jeon, Moongu

    2017-06-01

    Real time eye tracking has numerous applications in human computer interaction such as a mouse cursor control in a computer system. It is useful for persons with muscular or motion impairments. However, tracking the movement of the eye is complicated by occlusion due to blinking, head movement, screen glare, rapid eye movements, etc. In this work, we present the algorithmic and construction details of a real time eye tracking system. Our proposed system is an extension of Spatio-Temporal context learning through Kalman Filtering. Spatio-Temporal Context Learning offers state of the art accuracy in general object tracking but its performance suffers due to object occlusion. Addition of the Kalman filter allows the proposed method to model the dynamics of the motion of the eye and provide robust eye tracking in cases of occlusion. We demonstrate the effectiveness of this tracking technique by controlling the computer cursor in real time by eye movements.

  15. The Effect of Altitude on Intraocular Pressure in Vitrectomized Eyes with Sulfur Hexafluoride Tamponade by the Friedenwald Method: Rabbit Animal Model

    PubMed Central

    Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio

    2016-01-01

    The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity. PMID:27957500

  16. The Effect of Altitude on Intraocular Pressure in Vitrectomized Eyes with Sulfur Hexafluoride Tamponade by the Friedenwald Method: Rabbit Animal Model.

    PubMed

    Fromow-Guerra, Jans; Solís-Vivanco, Adriana; Velez-Montoya, Raul; Perez-Reguera, Adriana; Quiroz-Mercado, Hugo; Meza-de Regil, Armando; Papa-Oliva, Gabriela; Morales-Cantón, Virgilio

    2016-01-01

    The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF 6 , 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF 6 without vitrectomy. Guided by global positioning system, they were driven to the highest point of the highway connecting Mexico City with Puebla city and back, stopping every 300 m to assess intraocular pressure. The rabbit's scleral rigidity and estimation for human eyes were done by using the Friedenwald nomogram. Maximum altitude was 3209 m (Δ949 m). There were significant differences in intraocular pressure on the rabbit eyes filled with SF 6 at 100%, 50%, 25%, and 100% room air. Per every 100 m of altitude rise, the intraocular pressure increased by 1.53, 1.0046, 0.971, and 0.97 mmHg, respectively. Using the human Friedenwald rigidity coefficient, the human eye estimate for intraocular pressure change was 2.1, 1.8, 1.4, and 1.1 mmHg per every 100 m of attitude rise. Altitude changes have a significant impact on intraocular pressure. The final effect depends on the percentage of vitreous cavity fill and scleral rigidity.

  17. Learning-based saliency model with depth information.

    PubMed

    Ma, Chih-Yao; Hang, Hsueh-Ming

    2015-01-01

    Most previous studies on visual saliency focused on two-dimensional (2D) scenes. Due to the rapidly growing three-dimensional (3D) video applications, it is very desirable to know how depth information affects human visual attention. In this study, we first conducted eye-fixation experiments on 3D images. Our fixation data set comprises 475 3D images and 16 subjects. We used a Tobii TX300 eye tracker (Tobii, Stockholm, Sweden) to track the eye movement of each subject. In addition, this database contains 475 computed depth maps. Due to the scarcity of public-domain 3D fixation data, this data set should be useful to the 3D visual attention research community. Then, a learning-based visual attention model was designed to predict human attention. In addition to the popular 2D features, we included the depth map and its derived features. The results indicate that the extra depth information can enhance the saliency estimation accuracy specifically for close-up objects hidden in a complex-texture background. In addition, we examined the effectiveness of various low-, mid-, and high-level features on saliency prediction. Compared with both 2D and 3D state-of-the-art saliency estimation models, our methods show better performance on the 3D test images. The eye-tracking database and the MATLAB source codes for the proposed saliency model and evaluation methods are available on our website.

  18. Estimation of the mechanical properties of the eye through the study of its vibrational modes.

    PubMed

    Aloy, M Á; Adsuara, J E; Cerdá-Durán, P; Obergaulinger, M; Esteve-Taboada, J J; Ferrer-Blasco, T; Montés-Micó, R

    2017-01-01

    Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz-10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young's modulus, Poisson ratio) measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye.

  19. Animal models to assess the therapeutic efficacy of human serum and serum-converted platelet lysates for dry eye syndrome: Seeing is believing.

    PubMed

    Tseng, Ching-Li; Seghatchian, Jerard; Burnouf, Thierry

    2015-08-01

    There is much interest in the clinical use of serum-converted human blood or platelet concentrates in regenerative medicine, most specifically for wound healing and tissue repair of soft and hard tissues. The scientific rationale supporting the clinical efficacy of these preparations is based on the expectation that their physiological mixture of natural growth factors can orchestrate cell expansion and differentiation in vivo. However, a lack of standardization and regulatory oversight of these blood materials maintain a perception of uncertainty in the scientific and medical community on the value of these preparations for some clinical indications. More studies are needed to understand the mechanism of action underlying their expected efficacy and standardize their use, and benefit from their biological versatility. One application of serum is as eye drop for treating dry eye syndrome (DES), a multifactorial disease of the ocular surface, which has a prevalence of 15% of more in the population. DES can lead to chronic inflammation of the ocular surface, surface impairment in the cornea and conjunctiva, and, in patients with Sjogren syndrome, result in a disruption of the ocular surface epithelium. Objective experimental assessment of safety and efficacy of serum eye drops can help establish scientific rationale in optimal product composition and use. This can be achieved, first, through cell cultures with relevant cell models, before considering, then, animal studies using DES animal models. Several models have been evaluated and are reported in this concise review. The model we have developed encompasses the use of rabbits, where their eyes are treated with 0.1% benzalkonium chloride (BAC), a common preservative in ophthalmic agents, 3 times daily for 4 weeks. This relatively mild treatment results in moderate DES pathology, with a stable shortage of tear secretion throughout a 7-week study period, which we found suitable for assessing efficacy of serum eye drops. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Cross-matching: a modified cross-correlation underlying threshold energy model and match-based depth perception

    PubMed Central

    Doi, Takahiro; Fujita, Ichiro

    2014-01-01

    Three-dimensional visual perception requires correct matching of images projected to the left and right eyes. The matching process is faced with an ambiguity: part of one eye's image can be matched to multiple parts of the other eye's image. This stereo correspondence problem is complicated for random-dot stereograms (RDSs), because dots with an identical appearance produce numerous potential matches. Despite such complexity, human subjects can perceive a coherent depth structure. A coherent solution to the correspondence problem does not exist for anticorrelated RDSs (aRDSs), in which luminance contrast is reversed in one eye. Neurons in the visual cortex reduce disparity selectivity for aRDSs progressively along the visual processing hierarchy. A disparity-energy model followed by threshold nonlinearity (threshold energy model) can account for this reduction, providing a possible mechanism for the neural matching process. However, the essential computation underlying the threshold energy model is not clear. Here, we propose that a nonlinear modification of cross-correlation, which we term “cross-matching,” represents the essence of the threshold energy model. We placed half-wave rectification within the cross-correlation of the left-eye and right-eye images. The disparity tuning derived from cross-matching was attenuated for aRDSs. We simulated a psychometric curve as a function of graded anticorrelation (graded mixture of aRDS and normal RDS); this simulated curve reproduced the match-based psychometric function observed in human near/far discrimination. The dot density was 25% for both simulation and observation. We predicted that as the dot density increased, the performance for aRDSs should decrease below chance (i.e., reversed depth), and the level of anticorrelation that nullifies depth perception should also decrease. We suggest that cross-matching serves as a simple computation underlying the match-based disparity signals in stereoscopic depth perception. PMID:25360107

  1. [Energy saving and LED lamp lighting and human health].

    PubMed

    Deĭnego, V N; Kaptsov, V A

    2013-01-01

    The appearance of new sources of high-intensity with large proportion of blue light in the spectrum revealed new risks of their influence on the function of the eye and human health, especially for children and teenagers. There is an urgent need to reconsider the research methods of vision hygiene in conditions of energy-saving and LED bulbs lighting. On the basis of a systematic approach and knowledge of the newly discovered photosensitive receptors there was built hierarchical model of the interaction of "light environment - the eye - the system of formation of visual images - the hormonal system of the person - his psycho-physiological state." This approach allowed us to develop a range of risk for the negative impact of spectrum on the functions of the eye and human health, as well as to formulate the hygiene requirements for energy-efficient high-intensity light sources.

  2. Intraspecific eye color variability in birds and mammals: a recent evolutionary event exclusive to humans and domestic animals.

    PubMed

    Negro, Juan J; Carmen Blázquez, M; Galván, Ismael

    2017-01-01

    Human populations and breeds of domestic animals are composed of individuals with a multiplicity of eye (= iris) colorations. Some wild birds and mammals may have intraspecific eye color variability, but this variation seems to be due to the developmental stage of the individual, its breeding status, and/or sexual dimorphism. In other words, eye colour tends to be a species-specific trait in wild animals, and the exceptions are species in which individuals of the same age group or gender all develop the same eye colour. Domestic animals, by definition, include bird and mammal species artificially selected by humans in the last few thousand years. Humans themselves may have acquired a diverse palette of eye colors, likewise in recent evolutionary time, in the Mesolithic or in the Upper Paleolithic. We posit two previously unrecognized hypotheses regarding eye color variation: 1) eye coloration in wild animals of every species tends to be a fixed trait. 2) Humans and domestic animal populations, on the contrary, have eyes of multiple colors. Sexual selection has been invoked for eye color variation in humans, but this selection mode does not easily apply in domestic animals, where matings are controlled by the human breeder. Eye coloration is polygenic in humans. We wish to investigate the genetics of eye color in other animals, as well as the ecological correlates. Investigating the origin and function of eye colors will shed light on the reason why some species may have either light-colored irises (e.g., white, yellow or light blue) or dark ones (dark red, brown or black). The causes behind the vast array of eye colors across taxa have never been thoroughly investigated, but it may well be that all Darwinian selection processes are at work: sexual selection in humans, artificial selection for domestic animals, and natural selection (mainly) for wild animals.

  3. Dose conversion coefficients for photon exposure of the human eye lens

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  4. Action perception as hypothesis testing.

    PubMed

    Donnarumma, Francesco; Costantini, Marcello; Ambrosini, Ettore; Friston, Karl; Pezzulo, Giovanni

    2017-04-01

    We present a novel computational model that describes action perception as an active inferential process that combines motor prediction (the reuse of our own motor system to predict perceived movements) and hypothesis testing (the use of eye movements to disambiguate amongst hypotheses). The system uses a generative model of how (arm and hand) actions are performed to generate hypothesis-specific visual predictions, and directs saccades to the most informative places of the visual scene to test these predictions - and underlying hypotheses. We test the model using eye movement data from a human action observation study. In both the human study and our model, saccades are proactive whenever context affords accurate action prediction; but uncertainty induces a more reactive gaze strategy, via tracking the observed movements. Our model offers a novel perspective on action observation that highlights its active nature based on prediction dynamics and hypothesis testing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Primate social attention: Species differences and effects of individual experience in humans, great apes, and macaques.

    PubMed

    Kano, Fumihiro; Shepherd, Stephen V; Hirata, Satoshi; Call, Josep

    2018-01-01

    When viewing social scenes, humans and nonhuman primates focus on particular features, such as the models' eyes, mouth, and action targets. Previous studies reported that such viewing patterns vary significantly across individuals in humans, and also across closely-related primate species. However, the nature of these individual and species differences remains unclear, particularly among nonhuman primates. In large samples of human and nonhuman primates, we examined species differences and the effects of experience on patterns of gaze toward social movies. Experiment 1 examined the species differences across rhesus macaques, nonhuman apes (bonobos, chimpanzees, and orangutans), and humans while they viewed movies of various animals' species-typical behaviors. We found that each species had distinct viewing patterns of the models' faces, eyes, mouths, and action targets. Experiment 2 tested the effect of individuals' experience on chimpanzee and human viewing patterns. We presented movies depicting natural behaviors of chimpanzees to three groups of chimpanzees (individuals from a zoo, a sanctuary, and a research institute) differing in their early social and physical experiences. We also presented the same movies to human adults and children differing in their expertise with chimpanzees (experts vs. novices) or movie-viewing generally (adults vs. preschoolers). Individuals varied within each species in their patterns of gaze toward models' faces, eyes, mouths, and action targets depending on their unique individual experiences. We thus found that the viewing patterns for social stimuli are both individual- and species-specific in these closely-related primates. Such individual/species-specificities are likely related to both individual experience and species-typical temperament, suggesting that primate individuals acquire their unique attentional biases through both ontogeny and evolution. Such unique attentional biases may help them learn efficiently about their particular social environments.

  6. What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.

    PubMed

    Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian

    2013-10-01

    Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.

  7. Electrooculography-based continuous eye-writing recognition system for efficient assistive communication systems

    PubMed Central

    Shinozaki, Takahiro

    2018-01-01

    Human-computer interface systems whose input is based on eye movements can serve as a means of communication for patients with locked-in syndrome. Eye-writing is one such system; users can input characters by moving their eyes to follow the lines of the strokes corresponding to characters. Although this input method makes it easy for patients to get started because of their familiarity with handwriting, existing eye-writing systems suffer from slow input rates because they require a pause between input characters to simplify the automatic recognition process. In this paper, we propose a continuous eye-writing recognition system that achieves a rapid input rate because it accepts characters eye-written continuously, with no pauses. For recognition purposes, the proposed system first detects eye movements using electrooculography (EOG), and then a hidden Markov model (HMM) is applied to model the EOG signals and recognize the eye-written characters. Additionally, this paper investigates an EOG adaptation that uses a deep neural network (DNN)-based HMM. Experiments with six participants showed an average input speed of 27.9 character/min using Japanese Katakana as the input target characters. A Katakana character-recognition error rate of only 5.0% was achieved using 13.8 minutes of adaptation data. PMID:29425248

  8. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    NASA Astrophysics Data System (ADS)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.

  9. Polarimetric Glucose Sensing Using Brewster Reflection off of Eye Lens: Theoretical Analysis

    NASA Technical Reports Server (NTRS)

    Boeckle, Stefan; Rovati, Luigi; Ansari, Rafat R.

    2002-01-01

    An important task of in vivo polarimetric glucose sensing is to find an appropriate way to optically access the aqueous humor of the human eye. In this paper two different approaches are analyzed theoretically and applied to the eye model of Le Grand. First approach is the tangential path of Cote, et al. (G.L. Cot6, M.D. Fox, and R.B. Northrop: Noninvasive Optical Polarimetric Glucose Sensing Using a True Phase Measurement Technique. IEEE Transactions on Biomedical Engineering, vol. 39, no. 7, pp. 752-756, 1992.) and the second is a new scheme of this paper of applying Brewster reflection off the eye lens.

  10. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains

    PubMed Central

    2013-01-01

    Background DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person’s externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Methods Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Results Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Conclusions Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals. PMID:23317428

  11. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains.

    PubMed

    Draus-Barini, Jolanta; Walsh, Susan; Pośpiech, Ewelina; Kupiec, Tomasz; Głąb, Henryk; Branicki, Wojciech; Kayser, Manfred

    2013-01-14

    DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person's externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of eye and hair colour of deceased individuals.

  12. Successful gene therapy in older Rpe65-deficient dogs following subretinal injection of an adeno-associated vector expressing RPE65.

    PubMed

    Annear, Matthew J; Mowat, Freya M; Bartoe, Joshua T; Querubin, Janice; Azam, Selina A; Basche, Mark; Curran, Paul G; Smith, Alexander J; Bainbridge, James W B; Ali, Robin R; Petersen-Jones, Simon M

    2013-10-01

    Young Rpe65-deficient dogs have been used as a model for human RPE65 Leber congenital amaurosis (RPE65-LCA) in proof-of-concept trials of recombinant adeno-associated virus (rAAV) gene therapy. However, there are relatively few reports of the outcome of rAAV gene therapy in Rpe65-deficient dogs older than 2 years of age. The purpose of this study was to investigate the success of this therapy in older Rpe65-deficient dogs. Thirteen eyes were treated in dogs between 2 and 6 years old. An rAAV2 vector expressing the human RPE65 cDNA driven by the human RPE65 promoter was delivered by subretinal injection. Twelve of the 13 eyes had improved retinal function as assessed by electroretinography, and all showed improvement in vision at low lighting intensities. Histologic examination of five of the eyes was performed but found no correlation between electroretinogram (ERG) rescue and numbers of remaining photoreceptors. We conclude that functional rescue is still possible in older dogs and that the use of older Rpe65-deficient dogs, rather than young Rpe65-deficient dogs that have very little loss of photoreceptors, more accurately models the situation when treating human RPE65-LCA patients.

  13. Estimating Human Trabecular Meshwork Stiffness by Numerical Modeling and Advanced OCT Imaging.

    PubMed

    Wang, Ke; Johnstone, Murray A; Xin, Chen; Song, Shaozhen; Padilla, Steven; Vranka, Janice A; Acott, Ted S; Zhou, Kai; Schwaner, Stephen A; Wang, Ruikang K; Sulchek, Todd; Ethier, C Ross

    2017-09-01

    The purpose of this study was to estimate human trabecular meshwork (hTM) stiffness, thought to be elevated in glaucoma, using a novel indirect approach, and to compare results with direct en face atomic force microscopy (AFM) measurements. Postmortem human eyes were perfused to measure outflow facility and identify high- and low-flow regions (HF, LF) by tracer. Optical coherence tomography (OCT) images were obtained as Schlemm's canal luminal pressure was directly manipulated. TM stiffness was deduced by an inverse finite element modeling (FEM) approach. A series of AFM forcemaps was acquired along a line traversing the anterior angle on a radially cut flat-mount corneoscleral wedge with TM facing upward. The elastic modulus of normal hTM estimated by inverse FEM was 70 ± 20 kPa (mean ± SD), whereas glaucomatous hTM was slightly stiffer (98 ± 19 kPa). This trend was consistent with TM stiffnesses measured by AFM: normal hTM stiffness = 1.37 ± 0.56 kPa, which was lower than glaucomatous hTM stiffness (2.75 ± 1.19 kPa). None of these differences were statistically significant. TM in HF wedges was softer than that in LF wedges for both normal and glaucomatous eyes based on the inverse FEM approach but not by AFM. Outflow facility was significantly correlated with TM stiffness estimated by FEM in six human eyes (P = 0.018). TM stiffness is higher, but only modestly so, in glaucomatous patients. Outflow facility in both normal and glaucomatous human eyes appears to associate with TM stiffness. This evidence motivates further studies to investigate factors underlying TM biomechanical property regulation.

  14. Development and experimental verification of an intraocular scattering model

    NASA Astrophysics Data System (ADS)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  15. Elastography methods applicable to the eye

    NASA Astrophysics Data System (ADS)

    Khan, Altaf A.; Cortina, Soledad M.; Chamon, Wallace; Royston, Thomas J.

    2014-02-01

    Elastography is the mapping of tissues and cells by their respective mechanical properties, such as elasticity and viscosity. Our interest primarily lies in the human eye. Combining Scanning Laser Doppler Vibrometry (SLDV) with geometrically focused mechanical vibratory excitations of the cornea, it is possible to reconstruct these mechanical properties of the cornea. Experiments were conducted on phantom corneas as well as excised donor human corneas to test feasibility and derive a method of modeling. Finite element analysis was used to recreate the phantom studies and corroborate with the experimental data. Results are in close agreement. To further expand the study, lamb eyes were used in MR Elastography studies. 3D wave reconstruction was created and elastography maps were obtained. With MR Elastography, it would be possible to noninvasively measure mechanical properties of anatomical features not visible to SLDV, such as the lens and retina. Future plans include creating a more robust finite element model, improving the SLDV method for in-vivo application, and continuing experiments with MR Elastography.

  16. On the Visual Input Driving Human Smooth-Pursuit Eye Movements

    NASA Technical Reports Server (NTRS)

    Stone, Leland S.; Beutter, Brent R.; Lorenceau, Jean

    1996-01-01

    Current computational models of smooth-pursuit eye movements assume that the primary visual input is local retinal-image motion (often referred to as retinal slip). However, we show that humans can pursue object motion with considerable accuracy, even in the presence of conflicting local image motion. This finding indicates that the visual cortical area(s) controlling pursuit must be able to perform a spatio-temporal integration of local image motion into a signal related to object motion. We also provide evidence that the object-motion signal that drives pursuit is related to the signal that supports perception. We conclude that current models of pursuit should be modified to include a visual input that encodes perceived object motion and not merely retinal image motion. Finally, our findings suggest that the measurement of eye movements can be used to monitor visual perception, with particular value in applied settings as this non-intrusive approach would not require interrupting ongoing work or training.

  17. Experimental study of visual accommodation

    NASA Technical Reports Server (NTRS)

    Cornsweet, T. N.; Crane, H. D.

    1972-01-01

    A summary report of a research effort related to the human visual accommodation system is presented. A theoretical study of the accommodation system was made. Subsequent effort was aimed at the development of specialized instrumentation for experiments designed to lead to understanding the nature of the control system in human accommodation. The necessary instrumentation consisted primarily of: (1) an automatic optometer to measure the state of eye focus, (2) a focus stimulator device to control the apparent optical distance to any target, and (3) a two-dimensional eye tracker. The concepts and designs of the first two instruments have been published in the open literature, but this report contains the first detailed treatment of the Purkinje eye tracker developed under this program. The report also discusses an accommodation lag model to explain the ability of the eye to apparently know the polarity of focus error even though the blur on the retina is to a first-approximation an even function. The interaction of the accommodation and eye movement systems is also discussed, as is the ability to train the visual accommodation system to a surprisingly responsive condition in only a few hours of training.

  18. Mouse Models as Tools to Identify Genetic Pathways for Retinal Degeneration, as Exemplified by Leber's Congenital Amaurosis.

    PubMed

    Chang, Bo

    2016-01-01

    Leber's congenital amaurosis (LCA) is an inherited retinal degenerative disease characterized by severe loss of vision in the first year of life. In addition to early vision loss, a variety of other eye-related abnormalities including roving eye movements, deep-set eyes, and sensitivity to bright light also occur with this disease. Many animal models of LCA are available and the study them has led to a better understanding of the pathology of the disease, and has led to the development of therapeutic strategies aimed at curing or slowing down LCA. Mouse models, with their well-developed genetics and similarity to human physiology and anatomy, serve as powerful tools with which to investigate the etiology of human LCA. Such mice provide reproducible, experimental systems for elucidating pathways of normal development, function, designing strategies and testing compounds for translational research and gene-based therapies aimed at delaying the diseases progression. In this chapter, I describe tools used in the discovery and evaluation of mouse models of LCA including a Phoenix Image-Guided Optical Coherence Tomography (OCT) and a Diagnosys Espion Visual Electrophysiology System. Three mouse models are described, the rd3 mouse model for LCA12 and LCA1, the rd12 mouse model for LCA2, and the rd16 mouse model for LCA10.

  19. Atmospheric effects on laser eye safety and damage to instrumentation

    NASA Astrophysics Data System (ADS)

    Zilberman, Arkadi; Kopeika, Natan S.

    2017-10-01

    Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser detector/eye hazard depends on the interaction between the laser beam and the media in which it traverses. The environmental conditions including terrain features, atmospheric particulate and water content, and turbulence, may alter the laser's effect on the detector/eye. It is possible to estimate the performance of an electro-optical system as long as the atmospheric propagation of the laser beam can be adequately modeled. More recent experiments and modeling of atmospheric optics phenomena such as inner scale effect, aperture averaging, atmospheric attenuation in NIR-SWIR, and Cn2 modeling justify an update of previous eye/detector safety modeling. In the present work, the influence of the atmospheric channel on laser safety for personnel and instrumentation is shown on the basis of theoretical and experimental data of laser irradiance statistics for different atmospheric conditions. A method for evaluating the probability of damage and hazard distances associated with the use of laser systems in a turbulent atmosphere operating in the visible and NIR-SWIR portions of the electromagnetic spectrum is presented. It can be used as a performance prediction model for directed energy engagement of ground-based or air-based systems.

  20. Lévy-like diffusion in eye movements during spoken-language comprehension.

    PubMed

    Stephen, Damian G; Mirman, Daniel; Magnuson, James S; Dixon, James A

    2009-05-01

    This study explores the diffusive properties of human eye movements during a language comprehension task. In this task, adults are given auditory instructions to locate named objects on a computer screen. Although it has been convention to model visual search as standard Brownian diffusion, we find evidence that eye movements are hyperdiffusive. Specifically, we use comparisons of maximum-likelihood fit as well as standard deviation analysis and diffusion entropy analysis to show that visual search during language comprehension exhibits Lévy-like rather than Gaussian diffusion.

  1. Lévy-like diffusion in eye movements during spoken-language comprehension

    NASA Astrophysics Data System (ADS)

    Stephen, Damian G.; Mirman, Daniel; Magnuson, James S.; Dixon, James A.

    2009-05-01

    This study explores the diffusive properties of human eye movements during a language comprehension task. In this task, adults are given auditory instructions to locate named objects on a computer screen. Although it has been convention to model visual search as standard Brownian diffusion, we find evidence that eye movements are hyperdiffusive. Specifically, we use comparisons of maximum-likelihood fit as well as standard deviation analysis and diffusion entropy analysis to show that visual search during language comprehension exhibits Lévy-like rather than Gaussian diffusion.

  2. RNA-binding proteins in eye development and disease: implication of conserved RNA granule components.

    PubMed

    Dash, Soma; Siddam, Archana D; Barnum, Carrie E; Janga, Sarath Chandra; Lachke, Salil A

    2016-07-01

    The molecular biology of metazoan eye development is an area of intense investigation. These efforts have led to the surprising recognition that although insect and vertebrate eyes have dramatically different structures, the orthologs or family members of several conserved transcription and signaling regulators such as Pax6, Six3, Prox1, and Bmp4 are commonly required for their development. In contrast, our understanding of posttranscriptional regulation in eye development and disease, particularly regarding the function of RNA-binding proteins (RBPs), is limited. We examine the present knowledge of RBPs in eye development in the insect model Drosophila as well as several vertebrate models such as fish, frog, chicken, and mouse. Interestingly, of the 42 RBPs that have been investigated for their expression or function in vertebrate eye development, 24 (~60%) are recognized in eukaryotic cells as components of RNA granules such as processing bodies, stress granules, or other specialized ribonucleoprotein (RNP) complexes. We discuss the distinct developmental and cellular events that may necessitate potential RBP/RNA granule-associated RNA regulon models to facilitate posttranscriptional control of gene expression in eye morphogenesis. In support of these hypotheses, three RBPs and RNP/RNA granule components Tdrd7, Caprin2, and Stau2 are linked to ocular developmental defects such as congenital cataract, Peters anomaly, and microphthalmia in human patients or animal models. We conclude by discussing the utility of interdisciplinary approaches such as the bioinformatics tool iSyTE (integrated Systems Tool for Eye gene discovery) to prioritize RBPs for deriving posttranscriptional regulatory networks in eye development and disease. WIREs RNA 2016, 7:527-557. doi: 10.1002/wrna.1355 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.

  3. RNA Binding Proteins in Eye Development and Disease: Implication of Conserved RNA Granule Components

    PubMed Central

    Dash, Soma; Siddam, Archana D.; Barnum, Carrie E.; Janga, Sarath Chandra

    2016-01-01

    The molecular biology of metazoan eye development is an area of intense investigation. These efforts have led to the surprising recognition that although insect and vertebrate eyes have dramatically different structures, the orthologs or family members of several conserved transcription and signaling regulators such as Pax6, Six3, Prox1 and Bmp4 are commonly required for their development. In contrast, our understanding of post-transcriptional regulation in eye development and disease, particularly regarding the function of RNA binding proteins (RBPs), is limited. We examine the present knowledge of RBPs in eye development in the insect model Drosophila, as well as several vertebrate models such as fish, frog, chicken and mouse. Interestingly, of the 42 RBPs that have been investigated with for their expression or function in vertebrate eye development, 24 (~60%) are recognized in eukaryotic cells as components of RNA granules such as Processing bodies (P-bodies), Stress granules, or other specialized ribonucleoprotein (RNP) complexes. We discuss the distinct developmental and cellular events that may necessitate potential RBP/RNA granule-associated RNA regulon models to facilitate post-transcriptional control of gene expression in eye morphogenesis. In support of these hypotheses, three RBPs and RNP/RNA granule components Tdrd7, Caprin2 and Stau2 are linked to ocular developmental defects such as congenital cataract, Peters anomaly and microphthalmia in human patients or animal models. We conclude by discussing the utility of interdisciplinary approaches such as the bioinformatics tool iSyTE (integrated Systems Tool for Eye gene discovery) to prioritize RBPs for deriving post-transcriptional regulatory networks in eye development and disease. PMID:27133484

  4. P gene as an inherited biomarker of human eye color.

    PubMed

    Rebbeck, Timothy R; Kanetsky, Peter A; Walker, Amy H; Holmes, Robin; Halpern, Allan C; Schuchter, Lynn M; Elder, David E; Guerry, DuPont

    2002-08-01

    Human pigmentation, including eye color, has been associated with skin cancer risk. The P gene is the human homologue to the mouse pink-eye dilution locus and is responsible for oculocutaneous albinism type 2 and other phenotypes that confer eye hypopigmentation. The P gene is located on chromosome 15q11.2-q12, which is also the location of a putative eye pigmentation gene (EYCL3) inferred to exist by linkage analysis. Therefore, the P gene is a strong candidate for determination of human eye color. Using a sample of 629 normally pigmented individuals, we found that individuals were less likely to have blue or gray eyes if they had P gene variants Arg305Trp (P = 0.002), Arg419Gln (P = 0.001), or the combination of both variants (P = 0.003). These results suggest that P gene, in part, determines normal phenotypic variation in human eye color and may therefore represent an inherited biomarker of cutaneous cancer risk.

  5. Modeling and minimizing interference from corneal birefringence in retinal birefringence scanning for foveal fixation detection

    PubMed Central

    Irsch, Kristina; Gramatikov, Boris; Wu, Yi-Kai; Guyton, David

    2011-01-01

    Utilizing the measured corneal birefringence from a data set of 150 eyes of 75 human subjects, an algorithm and related computer program, based on Müller-Stokes matrix calculus, were developed in MATLAB for assessing the influence of corneal birefringence on retinal birefringence scanning (RBS) and for converging upon an optical/mechanical design using wave plates (“wave-plate-enhanced RBS”) that allows foveal fixation detection essentially independently of corneal birefringence. The RBS computer model, and in particular the optimization algorithm, were verified with experimental human data using an available monocular RBS-based eye fixation monitor. Fixation detection using wave-plate-enhanced RBS is adaptable to less cooperative subjects, including young children at risk for developing amblyopia. PMID:21750772

  6. Estimation of the mechanical properties of the eye through the study of its vibrational modes

    PubMed Central

    2017-01-01

    Measuring the eye’s mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz–10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young’s modulus, Poisson ratio) measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye. PMID:28922351

  7. A Mueller matrix model of Haidinger's brushes.

    PubMed

    Misson, Gary P

    2003-09-01

    Stokes vectors and Mueller matrices are used to model the polarisation properties (birefringence, dichroism and depolarisation) of any optical system, in particular the human eye. An explanation of the form and behaviour of the entoptic phenomenon of Haidinger's brushes is derived that complements and expands upon a previous study. The relationship between the appearance of Haidinger's brushes and intrinsic ocular retardation is quantified and the model allows prediction of the effect of any retarder of any orientation placed between a source of polarised light and the eye. The simple relationship of minimum contrast of Haidinger's brushes to the cosine of total retardation is derived.

  8. Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye.

    PubMed

    Harmening, Wolf M; Tiruveedhula, Pavan; Roorda, Austin; Sincich, Lawrence C

    2012-09-01

    A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye's optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye's transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the technique against hyperacute psychophysical performance and the standard chromatic human eye model. In vivo correction of chromatic dispersion will enable confocal multi-wavelength images of the living retina to be aligned, and allow targeted chromatic stimulation of the photoreceptor mosaic to be performed accurately with sub-cellular resolution.

  9. Three-dimensional ray tracing for refractive correction of human eye ametropies

    NASA Astrophysics Data System (ADS)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  10. How the Human Eye Focuses.

    ERIC Educational Resources Information Center

    Koretz, Jane F.; Handelman, George H.

    1988-01-01

    Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)

  11. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lv, Yang; Wang, Ruixing; Ma, Haotong

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides themore » aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.« less

  12. Localized viscoelasticity measurements with untethered intravitreal microrobots.

    PubMed

    Pokki, Juho; Ergeneman, Olgaç; Bergeles, Christos; Torun, Hamdi; Nelson, Bradley J

    2012-01-01

    Microrobots are a promising tool for medical interventions and micromanipulation. In this paper, we explore the concept of using microrobots for microrheology. Untethered magnetically actuated microrobots were used to characterize one of the most complex biofluids, the vitreous humor. In this work we began by experimentally characterizing the viscoelastic properties of an artificial vitreous humor. For comparison, its properties were also measured using special microcantilevers in an atomic force microscope (AFM) setup. Subsequently, an untethered device was used to study the vitreous humor of a porcine eye, which is a valid ex-vivo model of a human eye. Its viscoelasticity model was extracted, which was in agreement with the model of the artificial vitreous. The existing characterization methodology requires eye and vitreous humor dissection for the microrheology measurements. We envision that the method proposed here can be used in in vivo.

  13. A mathematical model for the deformation of the eyeball by an elastic band.

    PubMed

    Keeling, Stephen L; Propst, Georg; Stadler, Georg; Wackernagel, Werner

    2009-06-01

    In a certain kind of eye surgery, the human eyeball is deformed sustainably by the application of an elastic band. This article presents a mathematical model for the mechanics of the combined eye/band structure along with an algorithm to compute the model solutions. These predict the immediate and the lasting indentation of the eyeball. The model is derived from basic physical principles by minimizing a potential energy subject to a volume constraint. Assuming spherical symmetry, this leads to a two-point boundary-value problem for a non-linear second-order ordinary differential equation that describes the minimizing static equilibrium. By comparison with laboratory data, a preliminary validation of the model is given.

  14. The Barrie Jones Lecture—Eye care for the neglected population: challenges and solutions

    PubMed Central

    Rao, G N

    2015-01-01

    Globally, pockets of ‘neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of ‘Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people. PMID:25567375

  15. Comparison of smooth pursuit and combined eye-head tracking in human subjects with deficient labyrinthine function

    NASA Technical Reports Server (NTRS)

    Leigh, R. J.; Thurston, S. E.; Sharpe, J. A.; Ranalli, P. J.; Hamid, M. A.

    1987-01-01

    The effects of deficient labyrinthine function on smooth visual tracking with the eyes and head were investigated, using ten patients with bilateral peripheral vestibular disease and ten normal controls. Active, combined eye-head tracking (EHT) was significantly better in patients than smooth pursuit with the eyes alone, whereas normal subjects pursued equally well in both cases. Compensatory eye movements during active head rotation in darkness were always less in patients than in normal subjects. These data were used to examine current hypotheses that postulate central cancellation of the vestibulo-ocular reflex (VOR) during EHT. A model that proposes summation of an integral smooth pursuit command and VOR/compensatory eye movements is consistent with the findings. Observation of passive EHT (visual fixation of a head-fixed target during en bloc rotation) appears to indicate that in this mode parametric gain changes contribute to modulation of the VOR.

  16. Effect of elemental compositions on Monte Carlo dose calculations in proton therapy of eye tumors

    NASA Astrophysics Data System (ADS)

    Rasouli, Fatemeh S.; Farhad Masoudi, S.; Keshazare, Shiva; Jette, David

    2015-12-01

    Recent studies in eye plaque brachytherapy have found considerable differences between the dosimetric results by using a water phantom, and a complete human eye model. Since the eye continues to be simulated as water-equivalent tissue in the proton therapy literature, a similar study for investigating such a difference in treating eye tumors by protons is indispensable. The present study inquires into this effect in proton therapy utilizing Monte Carlo simulations. A three-dimensional eye model with elemental compositions is simulated and used to examine the dose deposition to the phantom. The beam is planned to pass through a designed beam line to moderate the protons to the desired energies for ocular treatments. The results are compared with similar irradiation to a water phantom, as well as to a material with uniform density throughout the whole volume. Spread-out Bragg peaks (SOBPs) are created by adding pristine peaks to cover a typical tumor volume. Moreover, the corresponding beam parameters recommended by the ICRU are calculated, and the isodose curves are computed. The results show that the maximum dose deposited in ocular media is approximately 5-7% more than in the water phantom, and about 1-1.5% less than in the homogenized material of density 1.05 g cm-3. Furthermore, there is about a 0.2 mm shift in the Bragg peak due to the tissue composition difference between the models. It is found that using the weighted dose profiles optimized in a water phantom for the realistic eye model leads to a small disturbance of the SOBP plateau dose. In spite of the plaque brachytherapy results for treatment of eye tumors, it is found that the differences between the simplified models presented in this work, especially the phantom containing the homogenized material, are not clinically significant in proton therapy. Taking into account the intrinsic uncertainty of the patient dose calculation for protons, and practical problems corresponding to applying patient-specific eye modeling, we found that the results of using a generic phantom containing homogenized material for proton therapy of eye tumors can be satisfactory for designing the beam.

  17. Micrometric Control of the Optics of the Human Eye: Environment or Genes?

    PubMed

    Tabernero, Juan; Hervella, Lucía; Benito, Antonio; Colodro-Conde, Lucía; Ordoñana, Juan R; Ruiz-Sanchez, Marcos; Marín, José María; Artal, Pablo

    2017-04-01

    The human eye has typically more optical aberrations than conventional artificial optical systems. While the lower order modes (defocus and astigmatism) are well studied, our purpose is to explore the influence of genes versus the environment on the higher order aberrations of the optical components of the eye. We have performed a classical twin study in a sample from the Region of Murcia (Spain). Optical aberrations using a Hartmann-Shack sensor (AOnEye Voptica SL, Murcia, Spain) and corneal aberrations (using corneal topography data) were measured in 138 eyes corresponding to 69 twins; 36 monozygotic (MZ) and 33 dizygotic (DZ) pairs (age 55 years, SD 7 years). Intraclass correlation coefficients (ICCs) were used to estimate how strongly aberrations of twins resemble each other, and genetic models were fitted to quantify heritability in the selected phenotypes. Genes had a significant influence in the variance of most of the higher order aberration terms (heritability from 40% to 70%). This genetic influence was observed similarly in both cornea and complete eye aberrations. Additionally, the compensation factor of spherical aberration in the eye (i.e., how much corneal spherical aberration was compensated by internal spherical aberration) was found under genetic influence (heritability of 68%). There is a significant genetic contribution to the variance of aberrations of the eye, not only at macroscopic levels, as in myopia or astigmatism, but also at microscopic levels, where a few micrometers changes in surface topography can produce a large difference in the value of the optical aberrations.

  18. Morphological and Hydrodynamic Correlations with Increasing Outflow Facility by Rho-Kinase Inhibitor Y-27632

    PubMed Central

    Yang, Chen-Yuan Charlie

    2014-01-01

    Abstract Rho-kinase inhibitors affect actomyosin cytoskeletal networks and have been shown to significantly increase outflow facility and lower intraocular pressure in various animal models and human eyes. This article summarizes common morphological changes in the trabecular meshwork induced by Rho-kinase inhibitors and specifically compares the morphological and hydrodynamic correlations with increased outflow facility by Rho-kinase inhibitor, Y-27632, in bovine, monkey, and human eyes under similar experimental conditions. Interspecies comparison has shown that morphological changes in the juxtacanalicular connective tissue (JCT) of these 3 species were different. However, these different morphological changes in the JCT, no matter if it's separation between the JCT and inner wall in bovine eyes, or separation between the JCT cells or between the JCT cells and their matrix in monkey eyes, or even no separation between the inner wall and the JCT but a more subtle expansion of the JCT in human eyes, appear to correlate with the increased percent change of outflow facility. More importantly, these different morphological changes all resulted in an increase in effective filtration area, which was positively correlated with increased outflow facility in all 3 species. These results suggest a link among changes in outflow facility, tissue architecture, and aqueous outflow pattern. Y-27632 increases outflow facility by redistributing aqueous outflow through a looser and larger area in the JCT. PMID:24460021

  19. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    NASA Astrophysics Data System (ADS)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.

  20. Custom-oriented wavefront sensor for human eye properties measurements

    NASA Astrophysics Data System (ADS)

    Galetskiy, Sergey; Letfullin, Renat; Dubinin, Alex; Cherezova, Tatyana; Belyakov, Alexey; Kudryashov, Alexis

    2005-12-01

    The problem of correct measurement of human eye aberrations is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). In this paper we show capabilities to measure aberrations by means of the aberrometer built in our lab together with Active Optics Ltd. We discuss the calibration of the aberrometer and show invalidity to use for the ophthalmic calibration purposes the analytical equation based on thin lens formula. We show that proper analytical equation suitable for calibration should have dependence on the square of the distance increment and we illustrate this both by experiment and by Zemax Ray tracing modeling. Also the error caused by inhomogeneous intensity distribution of the beam imaged onto the aberrometer's Shack-Hartmann sensor is discussed.

  1. A neural model of motion processing and visual navigation by cortical area MST.

    PubMed

    Grossberg, S; Mingolla, E; Pack, C

    1999-12-01

    Cells in the dorsal medial superior temporal cortex (MSTd) process optic flow generated by self-motion during visually guided navigation. A neural model shows how interactions between well-known neural mechanisms (log polar cortical magnification, Gaussian motion-sensitive receptive fields, spatial pooling of motion-sensitive signals and subtractive extraretinal eye movement signals) lead to emergent properties that quantitatively simulate neurophysiological data about MSTd cell properties and psychophysical data about human navigation. Model cells match MSTd neuron responses to optic flow stimuli placed in different parts of the visual field, including position invariance, tuning curves, preferred spiral directions, direction reversals, average response curves and preferred locations for stimulus motion centers. The model shows how the preferred motion direction of the most active MSTd cells can explain human judgments of self-motion direction (heading), without using complex heading templates. The model explains when extraretinal eye movement signals are needed for accurate heading perception, and when retinal input is sufficient, and how heading judgments depend on scene layouts and rotation rates.

  2. Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development

    NASA Astrophysics Data System (ADS)

    Sachs, Helmut G.; Schanze, Thomas; Brunner, Ursula; Sailer, Heiko; Wiesenack, Christoph

    2005-03-01

    Loss of photoreceptor function is responsible for a variety of blinding diseases, including retinitis pigmentosa. Advances in microtechnology have led to the development of electronic visual prostheses which are currently under investigation for the treatment of human blindness. The design of a subretinal prosthesis requires that the stimulation device should be implantable in the subretinal space of the eye. Current limitations in eye surgery have to be overcome to demonstrate the feasibility of this approach and to determine basic stimulation parameters. Therefore, polyimide film-bound electrodes were implanted in the subretinal space in anaesthetized domestic pigs as a prelude to electrical stimulation in acute experiments. Eight eyes underwent surgery to demonstrate the transscleral implantability of the device. Four of the eight eyes were stimulated electrically. In these four animals the cranium was prepared for epidural recording of evoked visual cortex responses, and stimulation was performed with sequences of current impulses. All eight subretinal implantation procedures were carried out successfully with polyimide film electrodes and each electrode was implanted beneath the outer retina of the posterior pole of the operated eyes. Four eyes were used for neurophysiological testing, involving recordings of epidural cortical responses to light and electrical stimulation. A light stimulus response, which occurred 40 ms after stimulation, proved the integrity of the operated eye. The electrical stimuli occurred about 20 ms after the onset of stimulation. The stimulation threshold was approximately 100 µA. Both the threshold and the cortical responses depended on the correspondence between retinal stimulation and cortical recording sites and on the number of stimulation electrodes used simultaneously. The subretinal implantation of complex stimulation devices using the transscleral procedure with consecutive subretinal stimulation is feasible in acute experiments in an animal model approximating to the situation in humans. The domestic pig is an appropriate animal model for basic testing of subretinal implants. Animal experiments with chronically implanted devices and long-term stimulation are advisable to prepare the field for successful human experiments. The first two authors (H G Sachs and Th Schanze) contributed equally to this paper.

  3. Scleral birefringence as measured by polarization-sensitive optical coherence tomography and ocular biometric parameters of human eyes in vivo.

    PubMed

    Yamanari, Masahiro; Nagase, Satoko; Fukuda, Shinichi; Ishii, Kotaro; Tanaka, Ryosuke; Yasui, Takeshi; Oshika, Tetsuro; Miura, Masahiro; Yasuno, Yoshiaki

    2014-05-01

    The relationship between scleral birefringence and biometric parameters of human eyes in vivo is investigated. Scleral birefringence near the limbus of 21 healthy human eyes was measured using polarization-sensitive optical coherence tomography. Spherical equivalent refractive error, axial eye length, and intraocular pressure (IOP) were measured in all subjects. IOP and scleral birefringence of human eyes in vivo was found to have statistically significant correlations (r = -0.63, P = 0.002). The slope of linear regression was -2.4 × 10(-2) deg/μm/mmHg. Neither spherical equivalent refractive error nor axial eye length had significant correlations with scleral birefringence. To evaluate the direct influence of IOP to scleral birefringence, scleral birefringence of 16 ex vivo porcine eyes was measured under controlled IOP of 5-60 mmHg. In these ex vivo porcine eyes, the mean linear regression slope between controlled IOP and scleral birefringence was -9.9 × 10(-4) deg/μm/mmHg. In addition, porcine scleral collagen fibers were observed with second-harmonic-generation (SHG) microscopy. SHG images of porcine sclera, measured on the external surface at the superior side to the cornea, showed highly aligned collagen fibers parallel to the limbus. In conclusion, scleral birefringence of healthy human eyes was correlated with IOP, indicating that the ultrastructure of scleral collagen was correlated with IOP. It remains to show whether scleral collagen ultrastructure of human eyes is affected by IOP as a long-term effect.

  4. Comparison of in vivo efficacy of different ocular lubricants in dry eye animal models.

    PubMed

    Zheng, Xiaodong; Goto, Tomoko; Ohashi, Yuichi

    2014-04-29

    To compare the efficacy of three types of ocular lubricants in protecting corneal epithelial cells in dry eye animal models. Ocular lubricants containing 0.1% or 0.3% sodium hyaluronate (SH), carboxymethylcellulose (CMC), or hydroxypropyl methylcellulose (HPMC) were tested. First, ocular lubricant containing 0.002% fluorescein was dropped onto the rabbit corneas. The fluorescein intensity as an index of retention was measured. Second, a rabbit dry eye model was made by holding the eye open with a speculum, and 50 μL of each ocular lubricant was dropped onto the cornea. After 3 hours, the corneas were stained with 1% methylene blue (MB), and the absorbance of MB was measured. Third, a rat dry eye model was treated with the ocular lubricants for 4 weeks, and the corneal fluorescein staining was scored. Eyes treated with physiological saline were used as controls. Finally, immunohistochemistry was used to analyze occludin, an epithelial barrier protein, in cultured human corneal epithelial cells pretreated with ocular lubricants and desiccated for 20 or 60 minutes. Our results showed that 0.3% SH had a significantly longer retention time than the other lubricants (all P < 0.01). The absorbance of MB was significantly lower in the 0.3% SH group. The corneas of rats exposed to 0.3% SH had significantly lower fluorescein staining scores. A significantly higher number of occludin-positive cells were found after exposure to 0.3% SH than other lubricants. Ocular lubricant containing 0.3% SH would be preferable to treat patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  5. The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation

    PubMed Central

    Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt

    2010-01-01

    Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.

  6. The adaptive nature of eye movements in linguistic tasks: how payoff and architecture shape speed-accuracy trade-offs.

    PubMed

    Lewis, Richard L; Shvartsman, Michael; Singh, Satinder

    2013-07-01

    We explore the idea that eye-movement strategies in reading are precisely adapted to the joint constraints of task structure, task payoff, and processing architecture. We present a model of saccadic control that separates a parametric control policy space from a parametric machine architecture, the latter based on a small set of assumptions derived from research on eye movements in reading (Engbert, Nuthmann, Richter, & Kliegl, 2005; Reichle, Warren, & McConnell, 2009). The eye-control model is embedded in a decision architecture (a machine and policy space) that is capable of performing a simple linguistic task integrating information across saccades. Model predictions are derived by jointly optimizing the control of eye movements and task decisions under payoffs that quantitatively express different desired speed-accuracy trade-offs. The model yields distinct eye-movement predictions for the same task under different payoffs, including single-fixation durations, frequency effects, accuracy effects, and list position effects, and their modulation by task payoff. The predictions are compared to-and found to accord with-eye-movement data obtained from human participants performing the same task under the same payoffs, but they are found not to accord as well when the assumptions concerning payoff optimization and processing architecture are varied. These results extend work on rational analysis of oculomotor control and adaptation of reading strategy (Bicknell & Levy, ; McConkie, Rayner, & Wilson, 1973; Norris, 2009; Wotschack, 2009) by providing evidence for adaptation at low levels of saccadic control that is shaped by quantitatively varying task demands and the dynamics of processing architecture. Copyright © 2013 Cognitive Science Society, Inc.

  7. A schematic eye model for the effects of translation and rotation of ocular components on peripheral astigmatism.

    PubMed

    Barnes, D A; Dunne, M C; Clement, R A

    1987-01-01

    The relative contributions of translation and rotation of the cornea and lens to peripheral astigmatic asymmetry have been investigated using a linear algebraic ray tracing method. It is believed that lenticular rotation is responsible for angle alpha, so bringing about peripheral astigmatic asymmetry, as normally occurs in human eyes over the temporal and nasal retina. Rotation of the cornea may be responsible for the small numbers of eyes which exhibit large amounts of peripheral astigmatic asymmetry. The effects of corneal rotation and translation on the dimensions of the entrance pupil are illustrated.

  8. Rabbit as an animal model for intravitreal pharmacokinetics: Clinical predictability and quality of the published data.

    PubMed

    Del Amo, Eva M; Urtti, Arto

    2015-08-01

    Intravitreal administration is the method of choice in drug delivery to the retina and/or choroid. Rabbit is the most commonly used animal species in intravitreal pharmacokinetics, but it has been criticized as being a poor model of human eye. The critique is based on some anatomical differences, properties of the vitreous humor, and observed differences in drug concentrations in the anterior chamber after intravitreal injections. We have systematically analyzed all published information on intravitreal pharmacokinetics in the rabbit and human eye. The analysis revealed major problems in the design of the pharmacokinetic studies. In this review we provide advice for study design. Overall, the pharmacokinetic parameters (clearance, volume of distribution, half-life) in the human and rabbit eye have good correlation and comparable absolute values. Therefore, reliable rabbit-to-man translation of intravitreal pharmacokinetics should be feasible. The relevant anatomical and physiological parameters in rabbit and man show only small differences. Furthermore, the claimed discrepancy between drug concentrations in the human and rabbit aqueous humor is not supported by the data analysis. Based on the available and properly conducted pharmacokinetic studies, the differences in the vitreous structure in rabbits and human patients do not lead to significant pharmacokinetic differences. This review is the first step towards inter-species translation of intravitreal pharmacokinetics. More information is still needed to dissect the roles of drug delivery systems, disease states, age and ocular manipulation on the intravitreal pharmacokinetics in rabbit and man. Anyway, the published data and the derived pharmacokinetic parameters indicate that the rabbit is a useful animal model in intravitreal pharmacokinetics. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. An epidemiological survey on road traffic crashes in Iran: application of the two logistic regression models.

    PubMed

    Bakhtiyari, Mahmood; Mehmandar, Mohammad Reza; Mirbagheri, Babak; Hariri, Gholam Reza; Delpisheh, Ali; Soori, Hamid

    2014-01-01

    Risk factors of human-related traffic crashes are the most important and preventable challenges for community health due to their noteworthy burden in developing countries in particular. The present study aims to investigate the role of human risk factors of road traffic crashes in Iran. Through a cross-sectional study using the COM 114 data collection forms, the police records of almost 600,000 crashes occurred in 2010 are investigated. The binary logistic regression and proportional odds regression models are used. The odds ratio for each risk factor is calculated. These models are adjusted for known confounding factors including age, sex and driving time. The traffic crash reports of 537,688 men (90.8%) and 54,480 women (9.2%) are analysed. The mean age is 34.1 ± 14 years. Not maintaining eyes on the road (53.7%) and losing control of the vehicle (21.4%) are the main causes of drivers' deaths in traffic crashes within cities. Not maintaining eyes on the road is also the most frequent human risk factor for road traffic crashes out of cities. Sudden lane excursion (OR = 9.9, 95% CI: 8.2-11.9) and seat belt non-compliance (OR = 8.7, CI: 6.7-10.1), exceeding authorised speed (OR = 17.9, CI: 12.7-25.1) and exceeding safe speed (OR = 9.7, CI: 7.2-13.2) are the most significant human risk factors for traffic crashes in Iran. The high mortality rate of 39 people for every 100,000 population emphasises on the importance of traffic crashes in Iran. Considering the important role of human risk factors in traffic crashes, struggling efforts are required to control dangerous driving behaviours such as exceeding speed, illegal overtaking and not maintaining eyes on the road.

  10. Optical properties of the mouse eye

    PubMed Central

    Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.

    2011-01-01

    The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598

  11. Objects predict fixations better than early saliency.

    PubMed

    Einhäuser, Wolfgang; Spain, Merrielle; Perona, Pietro

    2008-11-20

    Humans move their eyes while looking at scenes and pictures. Eye movements correlate with shifts in attention and are thought to be a consequence of optimal resource allocation for high-level tasks such as visual recognition. Models of attention, such as "saliency maps," are often built on the assumption that "early" features (color, contrast, orientation, motion, and so forth) drive attention directly. We explore an alternative hypothesis: Observers attend to "interesting" objects. To test this hypothesis, we measure the eye position of human observers while they inspect photographs of common natural scenes. Our observers perform different tasks: artistic evaluation, analysis of content, and search. Immediately after each presentation, our observers are asked to name objects they saw. Weighted with recall frequency, these objects predict fixations in individual images better than early saliency, irrespective of task. Also, saliency combined with object positions predicts which objects are frequently named. This suggests that early saliency has only an indirect effect on attention, acting through recognized objects. Consequently, rather than treating attention as mere preprocessing step for object recognition, models of both need to be integrated.

  12. A rabbit dry eye model induced by topical medication of a preservative benzalkonium chloride.

    PubMed

    Xiong, Cuiju; Chen, Dong; Liu, Jingbo; Liu, Bingqian; Li, Naiyang; Zhou, Yang; Liang, Xuanwei; Ma, Ping; Ye, Chengtian; Ge, Jian; Wang, Zhichong

    2008-05-01

    To establish a rabbit dry eye model with topical medication of the ocular preparation preservative benzalkonium chloride (BAC). Sixteen white rabbits were used. One eye of each rabbit was chosen randomly for topical administration of 0.1% BAC twice daily for 14 days. The other untreated eyes served as controls. Schirmer test, fluorescein, and rose bengal staining were performed before and after BAC treatment on days 3, 5, 7, and 14. Conjunctiva impression cytology specimens were collected on days 0, 7, and 14. The rabbits were killed after day 14. Immunofluorescence staining was performed to detect mucin-5 subtype AC (MUC5AC) on conjunctival cryosections. Cornea and conjunctiva structures were evaluated by light and electron microscopy. Compared with untreated controls, BAC-treated eyes showed significant decreases in Schirmer scores (P = 0.01) and increases in fluorescein scores (P < 0.001) on days 5, 7, and 14. A significant increase in rose bengal scores was noticed as early as day 3 (P = 0.001). Decreases in goblet cell density occurred on days 7 and 14 (P = 0.001). Decreased MUC5AC and histopathologic and ultrastructural disorders of the cornea and conjunctiva were also observed in the BAC group. These findings demonstrated that an ophthalmic preservative, benzalkonium chloride, induced a dry eye syndrome in rabbits with damage to the cornea and conjunctiva, decreased aqueous tear basal secretion, goblet cell loss, and MUC5AC deficiency. This rabbit model was consistent with human dry eye syndrome in both aqueous tear and mucin deficiency and may be appropriate for studying dry eye syndrome.

  13. Eye Movements in Darkness Modulate Self-Motion Perception.

    PubMed

    Clemens, Ivar Adrianus H; Selen, Luc P J; Pomante, Antonella; MacNeilage, Paul R; Medendorp, W Pieter

    2017-01-01

    During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first ( n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment ( n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation.

  14. Eye Movements in Darkness Modulate Self-Motion Perception

    PubMed Central

    Pomante, Antonella

    2017-01-01

    Abstract During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first (n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment (n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation. PMID:28144623

  15. Unprocessed real-time imaging of vitreoretinal surgical maneuvers using a microscope-integrated spectral-domain optical coherence tomography system.

    PubMed

    Hahn, Paul; Migacz, Justin; O'Connell, Rachelle; Izatt, Joseph A; Toth, Cynthia A

    2013-01-01

    We have recently developed a microscope-integrated spectral-domain optical coherence tomography (MIOCT) device towards intrasurgical cross-sectional imaging of surgical maneuvers. In this report, we explore the capability of MIOCT to acquire real-time video imaging of vitreoretinal surgical maneuvers without post-processing modifications. Standard 3-port vitrectomy was performed in human during scheduled surgery as well as in cadaveric porcine eyes. MIOCT imaging of human subjects was performed in healthy normal volunteers and intraoperatively at a normal pause immediately following surgical manipulations, under an Institutional Review Board-approved protocol, with informed consent from all subjects. Video MIOCT imaging of live surgical manipulations was performed in cadaveric porcine eyes by carefully aligning B-scans with instrument orientation and movement. Inverted imaging was performed by lengthening of the reference arm to a position beyond the choroid. Unprocessed MIOCT imaging was successfully obtained in healthy human volunteers and in human patients undergoing surgery, with visualization of post-surgical changes in unprocessed single B-scans. Real-time, unprocessed MIOCT video imaging was successfully obtained in cadaveric porcine eyes during brushing of the retina with the Tano scraper, peeling of superficial retinal tissue with intraocular forceps, and separation of the posterior hyaloid face. Real-time inverted imaging enabled imaging without complex conjugate artifacts. MIOCT is capable of unprocessed imaging of the macula in human patients undergoing surgery and of unprocessed, real-time, video imaging of surgical maneuvers in model eyes. These capabilities represent an important step towards development of MIOCT for efficient, real-time imaging of manipulations during human surgery.

  16. [Analysis of an ophthalmic pathology cohort of human fetal eyes with regard to interesting findings].

    PubMed

    Herwig, M C; Müller, A M; Holz, F G; Loeffler, K U

    2010-11-01

    Information on the evaluation of prenatal ocular findings is sparse. This article provides an overview of the morphology in a cohort of human fetal eyes, with particular emphasis on interesting findings. The study investigated 216 eyes from 115 human fetuses. The majority of fetal eyes presented with a regular phenotype. Rarely, unexpected findings were discovered in fetuses with or without systemic malformations. Routine evaluation of fetal eyes reveals-albeit rarely-new aspects providing further knowledge and occasionally enabling the exact classification of syndromes.

  17. Acute vitreoretinal trauma and inflammation after traumatic brain injury in mice.

    PubMed

    Evans, Lucy P; Newell, Elizabeth A; Mahajan, MaryAnn; Tsang, Stephen H; Ferguson, Polly J; Mahoney, Jolonda; Hue, Christopher D; Vogel, Edward W; Morrison, Barclay; Arancio, Ottavio; Nichols, Russell; Bassuk, Alexander G; Mahajan, Vinit B

    2018-03-01

    Limited attention has been given to ocular injuries associated with traumatic brain injury (TBI). The retina is an extension of the central nervous system and evaluation of ocular damage may offer a less-invasive approach to gauge TBI severity and response to treatment. We aim to characterize acute changes in the mouse eye after exposure to two different models of TBI to assess the utility of eye damage as a surrogate to brain injury. A model of blast TBI (bTBI) using a shock tube was compared to a lateral fluid percussion injury model (LFPI) using fluid pressure applied directly to the brain. Whole eyes were collected from mice 3 days post LFPI and 24 days post bTBI and were evaluated histologically using a hematoxylin and eosin stain. bTBI mice showed evidence of vitreous detachment in the posterior chamber in addition to vitreous hemorrhage with inflammatory cells. Subretinal hemorrhage, photoreceptor degeneration, and decreased cellularity in the retinal ganglion cell layer was also seen in bTBI mice. In contrast, eyes of LFPI mice showed evidence of anterior uveitis and subcapsular cataracts. We demonstrated that variations in the type of TBI can result in drastically different phenotypic changes within the eye. As such, molecular and phenotypic changes in the eye following TBI may provide valuable information regarding the mechanism, severity, and ongoing pathophysiology of brain injury. Because vitreous samples are easily obtained, molecular changes within the eye could be utilized as biomarkers of TBI in human patients.

  18. Numerical Modeling of Ophthalmic Response to Space

    NASA Technical Reports Server (NTRS)

    Nelson, E. S.; Myers, J. G.; Mulugeta, L.; Vera, J.; Raykin, J.; Feola, A.; Gleason, R.; Samuels, B.; Ethier, C. R.

    2015-01-01

    To investigate ophthalmic changes in spaceflight, we would like to predict the impact of blood dysregulation and elevated intracranial pressure (ICP) on Intraocular Pressure (IOP). Unlike other physiological systems, there are very few lumped parameter models of the eye. The eye model described here is novel in its inclusion of the human choroid and retrobulbar subarachnoid space (rSAS), which are key elements in investigating the impact of increased ICP and ocular blood volume. Some ingenuity was required in modeling the blood and rSAS compartments due to the lack of quantitative data on essential hydrodynamic quantities, such as net choroidal volume and blood flowrate, inlet and exit pressures, and material properties, such as compliances between compartments.

  19. System identification of perilymphatic fistula in an animal model

    NASA Technical Reports Server (NTRS)

    Wall, C. 3rd; Casselbrant, M. L.

    1992-01-01

    An acute animal model has been developed in the chinchilla for the study of perilymphatic fistulas. Micropunctures were made in three sites to simulate bony, round window, and oval window fistulas. The eye movements in response to pressure applied to the external auditory canal were recorded after micropuncture induction and in preoperative controls. The main pressure stimulus was a pseudorandom binary sequence (PRBS) that rapidly changed between plus and minus 200 mm of water. The PRBS stimulus, with its wide frequency bandwidth, produced responses clearly above the preoperative baseline in 78 percent of the runs. The response was better between 0.5 and 3.3 Hz than it was below 0.5 Hz. The direction of horizontal eye movement was toward the side of the fistula with positive pressure applied in 92 percent of the runs. Vertical eye movements were also observed. The ratio of vertical eye displacement to horizontal eye displacement depended upon the site of the micropuncture induction. Thus, such a ratio measurement may be clinically useful in the noninvasive localization of perilymphatic fistulas in humans.

  20. Does the foveal shape influence the image formation in human eyes?

    NASA Astrophysics Data System (ADS)

    Frey, Katharina; Zimmerling, Beatrice; Scheibe, Patrick; Rauscher, Franziska G.; Reichenbach, Andreas; Francke, Mike; Brunner, Robert

    2017-10-01

    In human eyes, the maximum visual acuity correlates locally with the fovea, a shallow depression in the retina. Previous examinations have been reduced to simple geometrical fovea models derived from postmortem preparations and considering only a few superficial ray propagation aspects. In the current study, an extended and realistic analysis of ray-optical simulations for a comprehensive anatomical realistic eye model for the anterior part and realistic aspherical human foveal topographical profiles deduced from in vivo optical coherence tomography (OCT) are presented, and the refractive index step at the transition from vitreous to retinal tissue is taken into account. The optical effect of a commonly shaped (averaged) and an extraordinarily shaped foveal pit were both compared to the analysis of an assumed pure spherical boundary layer. The influence of the aperture size, wavelength, and incident angle on the spot size and shape, as well as the axial focal and lateral centroid position is investigated, and a lateral displacement of about 2 μm and an axial shift of the best focal position of less than 4 μm are found. These findings indicate only small optical effects that are laterally in the range of inter-receptor distances and axially less than the photoreceptor outer segment dimension.

  1. A workforce in crisis: a case study to expand allied ophthalmic personnel.

    PubMed

    Astle, William; Simms, Craig; Anderson, Lynn

    2016-08-01

    To examine how the development of allied ophthalmic personnel training programs affects human resource capacity. Using a qualitative case study method conducted at a single Ontario institution, this article describes 6 years of establishing a 2-tiered allied ophthalmic personnel training program. The Kingston Ophthalmic Training Centre participated in the study with 8 leadership and program graduate interviews. To assess regional eye health workforce needs, a case study and iterative process used triangulations of the literature, case study, and qualitative interviews with stakeholders. This research was used to develop a model for establishing allied ophthalmic personnel training programs that would result in expanding human resource capacity. Current human resource capacity development and deployment is inadequate to provide the needed eye care services in Canada. A competency-based curriculum and accreditation model as the platform to develop formal academic training programs is essential. Access to quality eye care and patient services can be met by task-shifting from ophthalmologists to appropriately trained allied ophthalmic personnel. Establishing formal training programs is one important strategy to supplying a well-skilled, trained, and qualified ophthalmic workforce. This initiative meets the criteria required for quality, relevance, equity, and cost-effectiveness to meet the future demands for ophthalmic patient care. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  2. Gradient parameter and axial and field rays in the gradient-index crystalline lens model

    NASA Astrophysics Data System (ADS)

    Pérez, M. V.; Bao, C.; Flores-Arias, M. T.; Rama, M. A.; Gómez-Reino, C.

    2003-09-01

    Gradient-index models of the human lens have received wide attention in optometry and vision sciences for considering how changes in the refractive index profile with age and accommodation may affect refractive power. This paper uses the continuous asymmetric bi-elliptical model to determine gradient parameter and axial and field rays of the human lens in order to study the paraxial propagation of light through the crystalline lens of the eye.

  3. Inertial Movements of the Iris as the Origin of Postsaccadic Oscillations.

    PubMed

    Bouzat, S; Freije, M L; Frapiccini, A L; Gasaneo, G

    2018-04-27

    Recent studies on the human eye indicate that the pupil moves inside the eyeball due to deformations of the iris. Here we show that this phenomenon can be originated by inertial forces undergone by the iris during the rotation of the eyeball. Moreover, these forces affect the iris in such a way that the pupil behaves effectively as a massive particle. To show this, we develop a model based on the Newton equation on the noninertial reference frame of the eyeball. The model allows us to reproduce and interpret several important findings of recent eye-tracking experiments on saccadic movements. In particular, we get correct results for the dependence of the amplitude and period of the postsaccadic oscillations on the saccade size and also for the peak velocity. The model developed may serve as a tool for characterizing eye properties of individuals.

  4. Inertial Movements of the Iris as the Origin of Postsaccadic Oscillations

    NASA Astrophysics Data System (ADS)

    Bouzat, S.; Freije, M. L.; Frapiccini, A. L.; Gasaneo, G.

    2018-04-01

    Recent studies on the human eye indicate that the pupil moves inside the eyeball due to deformations of the iris. Here we show that this phenomenon can be originated by inertial forces undergone by the iris during the rotation of the eyeball. Moreover, these forces affect the iris in such a way that the pupil behaves effectively as a massive particle. To show this, we develop a model based on the Newton equation on the noninertial reference frame of the eyeball. The model allows us to reproduce and interpret several important findings of recent eye-tracking experiments on saccadic movements. In particular, we get correct results for the dependence of the amplitude and period of the postsaccadic oscillations on the saccade size and also for the peak velocity. The model developed may serve as a tool for characterizing eye properties of individuals.

  5. Coupling Osmolarity Dynamics within Human Tear Film on an Eye-Shaped Domain

    NASA Astrophysics Data System (ADS)

    Li, Longfei; Braun, R. J.; Driscoll, T. A.; Henshaw, W. D.; Banks, J. W.; King-Smith, P. E.

    2013-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease. We derived a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model concerns the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a new hybrid time stepping scheme (using variable step BDF and RKC) that was added to the framework. Results of our numerical simulations show good agreement with existing 1D models (for both tear film and osmolarity dynamics) and provide new insight about the osmolarity distribution over the ocular surface during the interblink.

  6. Human rather than ape-like orbital morphology allows much greater lateral visual field expansion with eye abduction

    PubMed Central

    Denion, Eric; Hitier, Martin; Levieil, Eric; Mouriaux, Frédéric

    2015-01-01

    While convergent, the human orbit differs from that of non-human apes in that its lateral orbital margin is significantly more rearward. This rearward position does not obstruct the additional visual field gained through eye motion. This additional visual field is therefore considered to be wider in humans than in non-human apes. A mathematical model was designed to quantify this difference. The mathematical model is based on published computed tomography data in the human neuro-ocular plane (NOP) and on additional anatomical data from 100 human skulls and 120 non-human ape skulls (30 gibbons; 30 chimpanzees / bonobos; 30 orangutans; 30 gorillas). It is used to calculate temporal visual field eccentricity values in the NOP first in the primary position of gaze then for any eyeball rotation value in abduction up to 45° and any lateral orbital margin position between 85° and 115° relative to the sagittal plane. By varying the lateral orbital margin position, the human orbit can be made “non-human ape-like”. In the Pan-like orbit, the orbital margin position (98.7°) was closest to the human orbit (107.1°). This modest 8.4° difference resulted in a large 21.1° difference in maximum lateral visual field eccentricity with eyeball abduction (Pan-like: 115°; human: 136.1°). PMID:26190625

  7. Dexamethasone nanowafer as an effective therapy for dry eye disease.

    PubMed

    Coursey, Terry G; Henriksson, Johanna Tukler; Marcano, Daniela C; Shin, Crystal S; Isenhart, Lucas C; Ahmed, Faheem; De Paiva, Cintia S; Pflugfelder, Stephen C; Acharya, Ghanashyam

    2015-09-10

    Dry eye disease is a major public health problem that affects millions of people worldwide. It is presently treated with artificial tear and anti-inflammatory eye drops that are generally administered several times a day and may have limited therapeutic efficacy. To improve convenience and efficacy, a dexamethasone (Dex) loaded nanowafer (Dex-NW) has been developed that can release the drug on the ocular surface for a longer duration of time than drops, during which it slowly dissolves. The Dex-NW was fabricated using carboxymethyl cellulose polymer and contains arrays of 500 nm square drug reservoirs filled with Dex. The in vivo efficacy of the Dex-NW was evaluated using an experimental mouse dry eye model. These studies demonstrated that once a day Dex-NW treatment on alternate days during a five-day treatment period was able to restore a healthy ocular surface and corneal barrier function with comparable efficacy to twice a day topically applied dexamethasone eye drop treatment. The Dex-NW was also very effective in down regulating expression of inflammatory cytokines (TNF-α, and IFN-γ), chemokines (CXCL-10 and CCL-5), and MMP-3, that are stimulated by dry eye. Despite less frequent dosing, the Dex-NW has comparable therapeutic efficacy to topically applied Dex eye drops in experimental mouse dry eye model, and these results provide a strong rationale for translation to human clinical trials for dry eye. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.

    PubMed

    Detorakis, Efstathios T; Drakonaki, Eleni E; Ginis, Harilaos; Karyotakis, Nikolaos; Pallikaris, Ioannis G

    2014-01-01

    A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.

  9. An eye tracking system for monitoring face scanning patterns reveals the enhancing effect of oxytocin on eye contact in common marmosets.

    PubMed

    Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito

    2017-09-01

    Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Theory and simulent design of a type of auto-self-protecting optical switches

    NASA Astrophysics Data System (ADS)

    Li, Binhong; Peng, Songcun

    1990-06-01

    As the use of lasers in the military and in the civilian economy increases with each passing day, it is often necessary for the human eye or sensitive instruments to observe weak lasers, such as the return waves of laser radar and laser communications signals; but it is also necessary to provide protection against damage to the eye from the strong lasers of enemy laser weapons. For this reason, it is necessary to have a kind of automatic optical self-protecting switch. Based upon a study of the transmitting and scattering characteristics of multilayer dielectric optical waveguides, a practical computer program is set up for designing a type of auto-self-protecting optical switch with a computer model by using the nonlinear property of dielectric layers and the plasma behavior of metal substrates. This technique can be used to protect the human eye and sensitive detectors from damage caused by strong laser beams.

  11. Isoplanatic patch of the human eye for arbitrary wavelengths

    NASA Astrophysics Data System (ADS)

    Han, Guoqing; Cao, Zhaoliang; Mu, Quanquan; Wang, Yukun; Li, Dayu; Wang, Shaoxin; Xu, Zihao; Wu, Daosheng; Hu, Lifa; Xuan, Li

    2018-03-01

    The isoplanatic patch of the human eye is a key parameter for the adaptive optics system (AOS) designed for retinal imaging. The field of view (FOV) usually sets to the same size as the isoplanatic patch to obtain high resolution images. However, it has only been measured at a specific wavelength. Here we investigate the wavelength dependence of this important parameter. An optical setup is initially designed and established in a laboratory to measure the isoplanatic patch at various wavelengths (655 nm, 730 nm and 808 nm). We established the Navarro wide-angle eye model in Zemax software to further validate our results, which suggested high consistency between the two. The isoplanatic patch as a function of wavelength was obtained within the range of visible to near-infrared, which can be expressed as: θ=0.0028 λ - 0 . 74. This work is beneficial for the AOS design for retinal imaging.

  12. Mapping the Perceptual Grain of the Human Retina

    PubMed Central

    Tuten, William S.; Roorda, Austin; Sincich, Lawrence C.

    2014-01-01

    In humans, experimental access to single sensory receptors is difficult to achieve, yet it is crucial for learning how the signals arising from each receptor are transformed into perception. By combining adaptive optics microstimulation with high-speed eye tracking, we show that retinal function can be probed at the level of the individual cone photoreceptor in living eyes. Classical psychometric functions were obtained from cone-sized microstimuli targeted to single photoreceptors. Revealed psychophysically, the cone mosaic also manifests a variable sensitivity to light across its surface that accords with a simple model of cone light capture. Because this microscopic grain of vision could be detected on the perceptual level, it suggests that photoreceptors can act individually to shape perception, if the normally suboptimal relay of light by the eye's optics is corrected. Thus the precise arrangement of cones and the exact placement of stimuli onto those cones create the initial retinal limits on signals mediating spatial vision. PMID:24741057

  13. Whole-eye transplantation: a look into the past and vision for the future.

    PubMed

    Bourne, D; Li, Y; Komatsu, C; Miller, M R; Davidson, E H; He, L; Rosner, I A; Tang, H; Chen, W; Solari, M G; Schuman, J S; Washington, K M

    2017-02-01

    Blindness afflicts ~39 million people worldwide. Retinal ganglion cells are unable to regenerate, making this condition irreversible in many cases. Whole-eye transplantation (WET) provides the opportunity to replace diseased retinal ganglion cells, as well as the entire optical system and surrounding facial tissue, if necessary. Recent success in face transplantation demonstrates that this may be a promising treatment for what has been to this time an incurable condition. An animal model for WET must be established to further enhance our knowledge of nerve regeneration, immunosuppression, and technical aspects of surgery. A systematic review of the literature was performed to evaluate studies describing animal models for WET. Only articles in which the eye was completely enucleated and reimplanted were included. Study methods and results were compared. In the majority of published literature, WET can result in recovery of vision in cold-blooded vertebrates. There are a few instances in which mammalian WET models demonstrate survival of the transplanted tissue following neurovascular anastomosis and the ability to maintain brief electroretinogram activity in the new host. In this study we review in cold-blooded vertebrates and mammalian animal models for WET and discuss prospects for future research for translation to human eye transplantation.

  14. Objective measurement of the optical image quality in the human eye

    NASA Astrophysics Data System (ADS)

    Navarro, Rafael M.

    2001-05-01

    This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.

  15. Assessment of minimum permissible geometrical parameters of a near-to-eye display.

    PubMed

    Valyukh, Sergiy; Slobodyanyuk, Oleksandr

    2015-07-20

    Light weight and small dimensions are some of the most important characteristics of near-to-eye displays (NEDs). These displays consist of two basic parts: a microdisplay for generating an image and supplementary optics in order to see the image. Nowadays, the pixel size of microdisplays may be less than 4 μm, which makes the supplementary optics the major factor in defining restrictions on a NED dimensions or at least on the distance between the microdisplay and the eye. The goal of the present work is to find answers to the following two questions: how small this distance can be in principle and what is the microdisplay maximum resolution that stays effective to see through the supplementary optics placed in immediate vicinity of the eye. To explore the first question, we consider an aberration-free magnifier, which is the initial stage in elaboration of a real optical system. In this case, the paraxial approximation and the transfer matrix method are ideal tools for simulation of light propagation from the microdisplay through the magnifier and the human eye's optical system to the retina. The human eye is considered according to the Gullstrand model. Parameters of the magnifier, its location with respect to the eye and the microdisplay, and the depth of field, which can be interpreted as the tolerance of the microdisplay position, are determined and discussed. The second question related to the microdisplay maximum resolution is investigated by using the principles of wave optics.

  16. Nonhuman Primate Studies to Advance Vision Science and Prevent Blindness.

    PubMed

    Mustari, Michael J

    2017-12-01

    Most primate behavior is dependent on high acuity vision. Optimal visual performance in primates depends heavily upon frontally placed eyes, retinal specializations, and binocular vision. To see an object clearly its image must be placed on or near the fovea of each eye. The oculomotor system is responsible for maintaining precise eye alignment during fixation and generating eye movements to track moving targets. The visual system of nonhuman primates has a similar anatomical organization and functional capability to that of humans. This allows results obtained in nonhuman primates to be applied to humans. The visual and oculomotor systems of primates are immature at birth and sensitive to the quality of binocular visual and eye movement experience during the first months of life. Disruption of postnatal experience can lead to problems in eye alignment (strabismus), amblyopia, unsteady gaze (nystagmus), and defective eye movements. Recent studies in nonhuman primates have begun to discover the neural mechanisms associated with these conditions. In addition, genetic defects that target the retina can lead to blindness. A variety of approaches including gene therapy, stem cell treatment, neuroprosthetics, and optogenetics are currently being used to restore function associated with retinal diseases. Nonhuman primates often provide the best animal model for advancing fundamental knowledge and developing new treatments and cures for blinding diseases. © The Author(s) 2017. Published by Oxford University Press on behalf of the National Academy of Sciences. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    PubMed

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the VOR does not become apparent until 47 ms after the onset of the stimulus. In contrast, the response to active high acceleration stimuli shows eye position-dependence from within 5 ms of the onset of the stimulus. A model using a VOR-Listing's law compromise strategy did not accurately predict the patterns observed in the data, raising questions about how the eye position-dependence of the VOR is generated. We suggest, in view of recent findings, that the phenomenon could arise due to the effects of fibromuscular pulleys on the functional pulling directions of the rectus muscles.

  18. Scanning mid-IR laser apparatus with eye tracking for refractive surgery

    NASA Astrophysics Data System (ADS)

    Telfair, William B.; Yoder, Paul R., Jr.; Bekker, Carsten; Hoffman, Hanna J.; Jensen, Eric F.

    1999-06-01

    A robust, real-time, dynamic eye tracker has been integrated with the short pulse mid-infrared laser scanning delivery system previously described. This system employs a Q- switched Nd:YAG laser pumped optical parametric oscillator operating at 2.94 micrometers. Previous ablation studies on human cadaver eyes and in-vivo cat eyes demonstrated very smooth ablations with extremely low damage levels similar to results with an excimer. A 4-month healing study with cats indicated no adverse healing effects. In order to treat human eyes, the tracker is required because the eyes move during the procedure due to both voluntary and involuntary motions such as breathing, heartbeat, drift, loss of fixation, saccades and microsaccades. Eye tracking techniques from the literature were compared. A limbus tracking system was best for this application. Temporal and spectral filtering techniques were implemented to reduce tracking errors, reject stray light, and increase signal to noise ratio. The expanded-capability system (IRVision AccuScan 2000 Laser System) has been tested in the lab on simulated eye targets, glass eyes, cadaver eyes, and live human subjects. Circular targets ranging from 10-mm to 14-mm diameter were successfully tracked. The tracker performed beyond expectations while the system performed myopic photorefractive keratectomy procedures on several legally blind human subjects.

  19. Monocarboxylate Transporters Mediate Fluorescein Uptake in Corneal Epithelial Cells.

    PubMed

    Sun, Yi-Chen; Liou, Hau-Min; Yeh, Po-Ting; Chen, Wei-Li; Hu, Fung-Rong

    2017-07-01

    To determine the presence of monocarboxylate transporter (MCT) in human and rabbit corneal epithelium and its role in transcellular fluorescein transportation in the cornea. The presence of MCTs in human and rabbit corneal epithelium was determined by RT-PCR and immunohistochemistry. Intracellular fluorescein uptake experiment was performed using cultured human corneal epithelial cells (HCECs). The involvement of MCT in fluorescein uptake was determined by addition of MCT inhibitors to HCECs and acute dry eye model on New Zealand albino rabbits by spectrophotometry, corneal impression cytology, and external eye photographs. MCT-1 and MCT-4 were identified in both human and rabbit corneal epithelia. A longer treatment period and a lower pH value in culture medium increased fluorescein uptake in HCECs. Fluorescein uptake in HCECs was decreased following addition of MCT inhibitors in a concentration-dependent manner. Impression cytology under fluorescent microscopy showed intracellular fluorescein staining in the rabbit cornea with acute dry eye treatment that was decreased following topical treatment of MCT inhibitors. Fluorescein ingress in corneal epithelial cells is mediated by the MCT family. Further study of MCT-mediated transport on HCECs may potentially benefit differential diagnosis and contribute better understandings of ocular surface disorders.

  20. 3D Viewing: Odd Perception - Illusion? reality? or both?

    NASA Astrophysics Data System (ADS)

    Kisimoto, K.; Iizasa, K.

    2008-12-01

    We live in the three dimensional space, don't we? It could be at least four dimensions, but that is another story. In either way our perceptual capability of 3D-Viewing is constrained by our 2D-perception (our intrinsic tools of perception). I carried out a few visual experiments using topographic data to show our intrinsic (or biological) disability (or shortcoming) in 3D-recognition of our world. Results of the experiments suggest: (1) 3D-surface model displayed on a 2D-computer screen (or paper) always has two interpretations of the 3D- surface geometry, if we choose one of the interpretation (in other word, if we are hooked by one perception of the two), we maintain its perception even if the 3D-model changes its viewing perspective in time shown on the screen, (2) more interesting is that 3D-real solid object (e.g.,made of clay) also gives above mentioned two interpretations of the geometry of the object, if we observe the object with one-eye. Most famous example of this viewing illusion is exemplified by a magician, who died in 2007, Jerry Andrus who made a super-cool paper crafted dragon which causes visual illusion to one-eyed viewer. I, by the experiments, confirmed this phenomenon in another perceptually persuasive (deceptive?) way. My conclusion is that this illusion is intrinsic, i.e. reality for human, because, even if we live in 3D-space, our perceptional tool (eyes) is composed of 2D sensors whose information is reconstructed or processed to 3D by our experience-based brain. So, (3) when we observe the 3D-surface-model on the computer screen, we are always one eye short even if we use both eyes. One last suggestion from my experiments is that recent highly sophisticated 3D- models might include too many information that human perceptions cannot handle properly, i.e. we might not be understanding the 3D world (geospace) at all, just illusioned.

  1. Standardized Full-Field Electroretinography in the Green Monkey (Chlorocebus sabaeus)

    PubMed Central

    Bouskila, Joseph; Javadi, Pasha; Palmour, Roberta M.; Bouchard, Jean-François; Ptito, Maurice

    2014-01-01

    Abstract Full-field electroretinography is an objective measure of retinal function, serving as an important diagnostic clinical tool in ophthalmology for evaluating the integrity of the retina. Given the similarity between the anatomy and physiology of the human and Green Monkey eyes, this species has increasingly become a favorable non-human primate model for assessing ocular defects in humans. To test this model, we obtained full-field electroretinographic recordings (ERG) and normal values for standard responses required by the International Society for Clinical Electrophysiology of Vision (ISCEV). Photopic and scotopic ERG recordings were obtained by full-field stimulation over a range of 6 log units of intensity in dark-adapted or light-adapted eyes of adult Green Monkeys (Chlorocebus sabaeus). Intensity, duration, and interval of light stimuli were varied separately. Reproducible values of amplitude and latency were obtained for the a- and b-waves, under well-controlled adaptation and stimulus conditions; the i-wave was also easily identifiable and separated from the a-b-wave complex in the photopic ERG. The recordings obtained in the healthy Green Monkey matched very well with those in humans and other non-human primate species (Macaca mulatta and Macaca fascicularis). These results validate the Green Monkey as an excellent non-human primate model, with potential to serve for testing retinal function following various manipulations such as visual deprivation or drug evaluation. PMID:25360686

  2. Defense Mapping Agency (DMA) Raster-to-Vector Analysis

    DTIC Science & Technology

    1984-11-30

    model) to pinpoint critical deficiencies and understand trade-offs between alternative solutions. This may be exemplified by the allocation of human ...process, prone to errors (i.e., human operator eye/motor control limitations), and its time consuming nature (as a function of data density). It should...achieved through the facilities of coinputer interactive graphics. Each error or anomaly is individually identified by a human operator and corrected

  3. Eye Tracking Metrics for Workload Estimation in Flight Deck Operation

    NASA Technical Reports Server (NTRS)

    Ellis, Kyle; Schnell, Thomas

    2010-01-01

    Flight decks of the future are being enhanced through improved avionics that adapt to both aircraft and operator state. Eye tracking allows for non-invasive analysis of pilot eye movements, from which a set of metrics can be derived to effectively and reliably characterize workload. This research identifies eye tracking metrics that correlate to aircraft automation conditions, and identifies the correlation of pilot workload to the same automation conditions. Saccade length was used as an indirect index of pilot workload: Pilots in the fully automated condition were observed to have on average, larger saccadic movements in contrast to the guidance and manual flight conditions. The data set itself also provides a general model of human eye movement behavior and so ostensibly visual attention distribution in the cockpit for approach to land tasks with various levels of automation, by means of the same metrics used for workload algorithm development.

  4. NEIBank: Genomics and bioinformatics resources for vision research

    PubMed Central

    Peterson, Katherine; Gao, James; Buchoff, Patee; Jaworski, Cynthia; Bowes-Rickman, Catherine; Ebright, Jessica N.; Hauser, Michael A.; Hoover, David

    2008-01-01

    NEIBank is an integrated resource for genomics and bioinformatics in vision research. It includes expressed sequence tag (EST) data and sequence-verified cDNA clones for multiple eye tissues of several species, web-based access to human eye-specific SAGE data through EyeSAGE, and comprehensive, annotated databases of known human eye disease genes and candidate disease gene loci. All expression- and disease-related data are integrated in EyeBrowse, an eye-centric genome browser. NEIBank provides a comprehensive overview of current knowledge of the transcriptional repertoires of eye tissues and their relation to pathology. PMID:18648525

  5. Fast ray-tracing of human eye optics on Graphics Processing Units.

    PubMed

    Wei, Qi; Patkar, Saket; Pai, Dinesh K

    2014-05-01

    We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. The pink gene encodes the Drosophila orthologue of the human Hermansky-Pudlak syndrome 5 (HPS5) gene.

    PubMed

    Syrzycka, Monika; McEachern, Lori A; Kinneard, Jennifer; Prabhu, Kristel; Fitzpatrick, Kathleen; Schulze, Sandra; Rawls, John M; Lloyd, Vett K; Sinclair, Donald A R; Honda, Barry M

    2007-06-01

    Hermansky-Pudlak syndrome (HPS) consists of a set of human autosomal recessive disorders, with symptoms resulting from defects in genes required for protein trafficking in lysosome-related organelles such as melanosomes and platelet dense granules. A number of human HPS genes and rodent orthologues have been identified whose protein products are key components of 1 of 4 different protein complexes (AP-3 or BLOC-1, -2, and -3) that are key participants in the process. Drosophila melanogaster has been a key model organism in demonstrating the in vivo significance of many genes involved in protein trafficking pathways; for example, mutations in the "granule group" genes lead to changes in eye colour arising from improper protein trafficking to pigment granules in the developing eye. An examination of the chromosomal positioning of Drosophila HPS gene orthologues suggested that CG9770, the Drosophila HPS5 orthologue, might correspond to the pink locus. Here we confirm this gene assignment, making pink the first eye colour gene in flies to be identified as a BLOC complex gene.

  7. Dosimetry of laser emission

    NASA Astrophysics Data System (ADS)

    Kirillov, A. I.; Morskov, V. F.; Ustinov, N. D.

    The basic criteria for dosimetric standards on photon, microwave, and ultraviolet emissions are reviewed. Attention is given to the biophysical effects of laser radiation, approaches to the evaluation of optical radiation hazard, and the effect of laser beams on the human eye. The fundamentals of the optical design of dosimeters are discussed, and an eye model is developed for a laser radiation meter. The discussion also covers the design of the electronic circuit of dosimeters and an evaluation of measurement errors.

  8. Discrimination between smiling faces: Human observers vs. automated face analysis.

    PubMed

    Del Líbano, Mario; Calvo, Manuel G; Fernández-Martín, Andrés; Recio, Guillermo

    2018-05-11

    This study investigated (a) how prototypical happy faces (with happy eyes and a smile) can be discriminated from blended expressions with a smile but non-happy eyes, depending on type and intensity of the eye expression; and (b) how smile discrimination differs for human perceivers versus automated face analysis, depending on affective valence and morphological facial features. Human observers categorized faces as happy or non-happy, or rated their valence. Automated analysis (FACET software) computed seven expressions (including joy/happiness) and 20 facial action units (AUs). Physical properties (low-level image statistics and visual saliency) of the face stimuli were controlled. Results revealed, first, that some blended expressions (especially, with angry eyes) had lower discrimination thresholds (i.e., they were identified as "non-happy" at lower non-happy eye intensities) than others (especially, with neutral eyes). Second, discrimination sensitivity was better for human perceivers than for automated FACET analysis. As an additional finding, affective valence predicted human discrimination performance, whereas morphological AUs predicted FACET discrimination. FACET can be a valid tool for categorizing prototypical expressions, but is currently more limited than human observers for discrimination of blended expressions. Configural processing facilitates detection of in/congruence(s) across regions, and thus detection of non-genuine smiling faces (due to non-happy eyes). Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Adaptive model of the aging emmetropic eye and its changes with accommodation.

    PubMed

    Navarro, Rafael

    2014-11-20

    A general schematic model of the optical system of the emmetropic human eye is proposed, capable of adapting to changes with age and accommodation through adjustment of the optical surfaces and the internal gradient index structure of the lens. The specific models of the cornea and lens consist of minor generalizations of previous work by assuming them to be the sum of a biconic plus three higher order Zernike modes. The internal gradient index distribution adapts to the external shape so that the analytical expression is invariant with the changes with age and accommodation. The model also includes tips, tilts, and decentrations of the surfaces according to experimental findings. The specific parameters of these models are either constants or functions of age and/or accommodation. The model is polychromatic, and its optical performance was evaluated along the keratometric axis. Chromatic aberrations (longitudinal and transverse), astigmatism, coma, trefoil, and spherical aberration show good agreement with experimental averages. The change of these aberrations as a function of age or accommodation is also consistent with experimental findings (except for trefoil in eyes older than 50 years). This means that the average structure seems to predict the average performance. Nevertheless, the present model is too schematic to account for other higher order aberrations, such as tetrafoil, also present in real eyes. © 2014 ARVO.

  10. Binocular eye movement control and motion perception: what is being tracked?

    PubMed

    van der Steen, Johannes; Dits, Joyce

    2012-10-19

    We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking.

  11. Binocular Eye Movement Control and Motion Perception: What Is Being Tracked?

    PubMed Central

    van der Steen, Johannes; Dits, Joyce

    2012-01-01

    Purpose. We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. Methods. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Results. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. Conclusions. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking. PMID:22997286

  12. DNA methyl transferases are differentially expressed in the human anterior eye segment.

    PubMed

    Bonnin, Nicolas; Belville, Corinne; Chiambaretta, Frédéric; Sapin, Vincent; Blanchon, Loïc

    2014-08-01

    DNA methylation is an epigenetic mark involved in the control of genes expression. Abnormal epigenetic events have been reported in human pathologies but weakly documented in eye diseases. The purpose of this study was to establish DNMT mRNA and protein expression levels in the anterior eye segment tissues and their related (primary or immortalized) cell cultures as a first step towards future in vivo and in vitro methylomic studies. Total mRNA was extracted from human cornea, conjunctiva, anterior lens capsule, trabeculum and related cell cultures (cornea epithelial, trabecular meshwork, keratocytes for primary cells; and HCE, Chang, B-3 for immortalized cells). cDNA was quantified by real-time PCR using specific primers for DNMT1, 2, 3A, 3B and 3L. Immunolocalization assays were carried out on human cornea using specific primary antibodies for DNMT1, 2 and 3A, 3B and 3L. All DNMT transcripts were detected in human cornea, conjunctiva, anterior lens capsule, trabeculum and related cells but showed statistically different expression patterns between tissues and cells. DNMT2 protein presented a specific and singular expression pattern in corneal endothelium. This study produced the first inventory of the expression patterns of DNMTs in human adult anterior eye segment. Our research highlights that DNA methylation cannot be ruled out as a way to bring new insights into well-known ocular diseases. In addition, future DNA methylation studies using various cells as experimental models need to be conducted with attention to approach the results analysis from a global tissue perspective. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Characteristics of the retinal images of the eye optical systems with implanted intraocular lenses

    NASA Astrophysics Data System (ADS)

    Siedlecki, Damian; Zając, Marek; Nowak, Jerzy

    2007-04-01

    Cataract, or opacity of crystalline lens in the human eye is one of the most frequent reasons of blindness nowadays. Removing the pathologically altered crystalline lens and replacing it with artificial implantable intraocular lens (IOL) is practically the only therapy in this illness. There exist a wide variety of artificial IOL types on the medical market, differing in their material and design (shape). In this paper six exemplary models of IOL's made of PMMA, acrylic and silicone are considered. The retinal image quality is analyzed numerically on the basis of Liou-Brennan eye model with these IOL's inserted. Chromatic aberration as well as polychromatic Point Spread Function and Modulation Transfer Function are calculated as most adequate image quality measures. The calculations made with Zemax TM software show the importance of chromatic aberration correction.

  14. Simulation of keratoconus observation in photorefraction

    NASA Astrophysics Data System (ADS)

    Chen, Ying-Ling; Tan, B.; Baker, K.; Lewis, J. W. L.; Swartz, T.; Jiang, Y.; Wang, M.

    2006-11-01

    In the recent years, keratoconus (KC) has increasingly gained attention due to its treatment options and to the popularity of keratorefractive surgery. This paper investigates the potential of identification of KC using photorefraction (PR), an optical technique that is similar to objective retinoscopy and is commonly used for large-scale ocular screening. Using personalized eye models of both KC and pre-LASIK patients, computer simulations were performed to achieve visualization of this ophthalmic measurement. The simulations are validated by comparing results to two sets of experimental measurements. These PR images show distinguishable differences between KC eyes and eyes that are either normal or ametropic. The simulation technique with personalized modeling can be extended to other ophthalmic instrument developments. It makes possible investigation with the least number of real human subjects. The application is also of great interest in medical training.

  15. Material Properties of the Posterior Human Sclera☆

    PubMed Central

    Grytz, Rafael; Fazio, Massimo A.; Girard, Michael J.A.; Libertiaux, Vincent; Bruno, Luigi; Gardiner, Stuart; Girkin, Christopher A.; Downs, J. Crawford

    2013-01-01

    To characterize the material properties of posterior and peripapillary sclera from human donors, and to investigate the macro- and micro-scale strains as potential control mechanisms governing mechanical homeostasis. Posterior scleral shells from 9 human donors aged 57–90 years were subjected to IOP elevations from 5 to 45 mmHg and the resulting full-field displacements were recorded using laser speckle interferometry. Eye-specific finite element models were generated based on experimentally measured scleral shell surface geometry and thickness. Inverse numerical analyses were performed to identify material parameters for each eye by matching experimental deformation measurements to model predictions using a microstructure-based constitutive formulation that incorporates the crimp response and anisotropic architecture of scleral collagen fibrils. The material property fitting produced models that fit both the overall and local deformation responses of posterior scleral shells very well. The nonlinear stiffening of the sclera with increasing IOP was well reproduced by the uncrimping of scleral collagen fibrils, and a circumferentially-aligned ring of collagen fibrils around the scleral canal was predicted in all eyes. Macroscopic in-plane strains were significantly higher in peripapillary region then in the mid-periphery. In contrast, the meso- and micro-scale strains at the collagen network and collagen fibril level were not significantly different between regions. The elastic response of the posterior human sclera can be characterized by the anisotropic architecture and crimp response of scleral collagen fibrils. The similar collagen fibril strains in the peripapillary and mid-peripheral regions support the notion that the scleral collagen architecture including the circumpapillary ring of collagen fibrils evolved to establish optimal load bearing conditions at the collagen fibril level. PMID:23684352

  16. A Theory of Eye Movements during Target Acquisition

    ERIC Educational Resources Information Center

    Zelinsky, Gregory J.

    2008-01-01

    The gaze movements accompanying target localization were examined via human observers and a computational model (target acquisition model [TAM]). Search contexts ranged from fully realistic scenes to toys in a crib to Os and Qs, and manipulations included set size, target eccentricity, and target-distractor similarity. Observers and the model…

  17. Quality of image of grating target placed in model of human eye with corneal aberrations as observed through multifocal intraocular lenses.

    PubMed

    Inoue, Makoto; Noda, Toru; Mihashi, Toshifumi; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito

    2011-04-01

    To evaluate the quality of the image of a grating target placed in a model eye viewed through multifocal intraocular lenses (IOLs). Laboratory investigation. Refractive (NXG1 or PY60MV) or diffractive (ZM900 or SA60D3) multifocal IOLs were placed in a fluid-filled model eye with human corneal aberrations. A United States Air Force resolution target was placed on the posterior surface of the model eye. A flat contact lens or a wide-field contact lens was placed on the cornea. The contrasts of the gratings were evaluated under endoillumination and compared to those obtained through a monofocal IOL. The grating images were clear when viewed through the flat contact lens and through the central far-vision zone of the NXG1 and PY60MV, although those through the near-vision zone were blurred and doubled. The images observed through the central area of the ZM900 with flat contact lens were slightly defocused but the images in the periphery were very blurred. The contrast decreased significantly in low frequencies (P<.001). The images observed through the central diffractive zone of the SA60D3 were slightly blurred, although the images in the periphery were clearer than that of the ZM900. The images were less blurred in all of the refractive and diffractive IOLs with the wide-field contact lens. Refractive and diffractive multifocal IOLs blur the grating target but less with the wide-angle viewing system. The peripheral multifocal optical zone may be more influential on the quality of the images with contact lens system. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. The mouse p (pink-eyed dilution) and human P genes, oculocutaneous albinism type 2 (OCA2), and melanosomal pH.

    PubMed

    Brilliant, M H

    2001-04-01

    Recessive mutations of the mouse p (pink-eyed dilution) gene lead to hypopigmentation of the eyes, skin, and fur. Mice lacking a functional p protein have pink eyes and light gray fur (if non-agouti) or cream-colored fur (if agouti). The human orthologue is the P protein. Humans lacking a functional P protein have oculocutaneous albinism type 2 (OCA2). Melanocytes from p-deficient mice or OCA2 individuals contain small, minimally pigmented melanosomes. The mouse and human proteins are predicted to have 12 membrane spanning domains and possess significant sequence homology to a number of membrane transport proteins, some of which are involved in the transport of anions. The p protein has been localized to the melanosome membrane. Recently, it has been shown that melanosomes from p protein-deficient melanocytes have an abnormal pH. Melanosomes in cultured melanocytes derived from wild-type mice are typically acidic, whereas melanosomes from p protein-deficient mice are non-acidic. Melanosomes and related endosome-derived organelles (i.e., lysosomes) are thought to have an adenosine triphosphate (ATP)-driven proton pump that helps to generate an acidic lumen. To compensate for the charge of these protons, anions must also be transported to the lumen of the melanosome. In light of these observations, a model of p protein function is presented in which the p protein, together with the ATP-driven proton pump, regulates the pH of the melanosome.

  19. Brachytherapy treatment simulation of strontium-90 and ruthenium-106 plaques on small size posterior uveal melanoma using MCNPX code

    NASA Astrophysics Data System (ADS)

    Barbosa, N. A.; da Rosa, L. A. R.; Facure, A.; Braz, D.

    2014-02-01

    Concave eye applicators with 90Sr/90Y and 106Ru/106Rh beta-ray sources are usually used in brachytherapy for the treatment of superficial intraocular tumors as uveal melanoma with thickness up to 5 mm. The aim of this work consisted in using the Monte Carlo code MCNPX to calculate the 3D dose distribution on a mathematical model of the human eye, considering 90Sr/90Y and 160Ru/160Rh beta-ray eye applicators, in order to treat a posterior uveal melanoma with a thickness 3.8 mm from the choroid surface. Mathematical models were developed for the two ophthalmic applicators, CGD produced by BEBIG Company and SIA.6 produced by the Amersham Company, with activities 1 mCi and 4.23 mCi respectively. They have a concave form. These applicators' mathematical models were attached to the eye model and the dose distributions were calculated using the MCNPX *F8 tally. The average doses rates were determined in all regions of the eye model. The *F8 tally results showed that the deposited energy due to the applicator with the radionuclide 106Ru/106Rh is higher in all eye regions, including tumor. However the average dose rate in the tumor region is higher for the applicator with 90Sr/90Y, due to its high activity. Due to the dosimetric characteristics of these applicators, the PDD value for 3 mm water is 73% for the 106Ru/106Rh applicator and 60% for 90Sr/90Y applicator. For a better choice of the applicator type and radionuclide it is important to know the thickness of the tumor and its location.

  20. Violating instructed human agency: An fMRI study on ocular tracking of biological and nonbiological motion stimuli.

    PubMed

    Gertz, Hanna; Hilger, Maximilian; Hegele, Mathias; Fiehler, Katja

    2016-09-01

    Previous studies have shown that beliefs about the human origin of a stimulus are capable of modulating the coupling of perception and action. Such beliefs can be based on top-down recognition of the identity of an actor or bottom-up observation of the behavior of the stimulus. Instructed human agency has been shown to lead to superior tracking performance of a moving dot as compared to instructed computer agency, especially when the dot followed a biological velocity profile and thus matched the predicted movement, whereas a violation of instructed human agency by a nonbiological dot motion impaired oculomotor tracking (Zwickel et al., 2012). This suggests that the instructed agency biases the selection of predictive models on the movement trajectory of the dot motion. The aim of the present fMRI study was to examine the neural correlates of top-down and bottom-up modulations of perception-action couplings by manipulating the instructed agency (human action vs. computer-generated action) and the observable behavior of the stimulus (biological vs. nonbiological velocity profile). To this end, participants performed an oculomotor tracking task in an MRI environment. Oculomotor tracking activated areas of the eye movement network. A right-hemisphere occipito-temporal cluster comprising the motion-sensitive area V5 showed a preference for the biological as compared to the nonbiological velocity profile. Importantly, a mismatch between instructed human agency and a nonbiological velocity profile primarily activated medial-frontal areas comprising the frontal pole, the paracingulate gyrus, and the anterior cingulate gyrus, as well as the cerebellum and the supplementary eye field as part of the eye movement network. This mismatch effect was specific to the instructed human agency and did not occur in conditions with a mismatch between instructed computer agency and a biological velocity profile. Our results support the hypothesis that humans activate a specific predictive model for biological movements based on their own motor expertise. A violation of this predictive model causes costs as the movement needs to be corrected in accordance with incoming (nonbiological) sensory information. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Modifiers of radiation effects in the eye

    NASA Astrophysics Data System (ADS)

    Kleiman, Norman J.; Stewart, Fiona A.; Hall, Eric J.

    2017-11-01

    World events, including the threat of radiological terrorism and the fear of nuclear accidents, have highlighted an urgent need to develop medical countermeasures to prevent or reduce radiation injury. Similarly, plans for manned spaceflight to a near-Earth asteroid or journey to Mars raise serious concerns about long-term effects of space radiation on human health and the availability of suitable therapeutic interventions. At the same time, the need to protect normal tissue from the deleterious effects of radiotherapy has driven considerable research into the design of effective radioprotectors. For more than 70 years, animal models of radiation cataract have been utilized to test the short and long-term efficacy of various radiation countermeasures. While some compounds, most notably the Walter Reed (WR) class of radioprotectors, have reported limited effectiveness when given before exposure to low-LET radiation, the human toxicity of these molecules at effective doses limits their usefulness. Furthermore, while there has been considerable testing of eye responses to X- and gamma irradiation, there is limited information about using such models to limit the injurious effects of heavy ions and neutrons on eye tissue. A new class of radioprotector molecules, including the sulfhydryl compound PrC-210, are reported to be effective at much lower doses and with far less side effects. Their ability to modify ocular radiation damage has not yet been examined. The ability to non-invasively measure sensitive, radiation-induced ocular changes over long periods of time makes eye models an attractive option to test the radioprotective and radiation mitigating abilities of new novel compounds.

  2. Eye movement-invariant representations in the human visual system.

    PubMed

    Nishimoto, Shinji; Huth, Alexander G; Bilenko, Natalia Y; Gallant, Jack L

    2017-01-01

    During natural vision, humans make frequent eye movements but perceive a stable visual world. It is therefore likely that the human visual system contains representations of the visual world that are invariant to eye movements. Here we present an experiment designed to identify visual areas that might contain eye-movement-invariant representations. We used functional MRI to record brain activity from four human subjects who watched natural movies. In one condition subjects were required to fixate steadily, and in the other they were allowed to freely make voluntary eye movements. The movies used in each condition were identical. We reasoned that the brain activity recorded in a visual area that is invariant to eye movement should be similar under fixation and free viewing conditions. In contrast, activity in a visual area that is sensitive to eye movement should differ between fixation and free viewing. We therefore measured the similarity of brain activity across repeated presentations of the same movie within the fixation condition, and separately between the fixation and free viewing conditions. The ratio of these measures was used to determine which brain areas are most likely to contain eye movement-invariant representations. We found that voxels located in early visual areas are strongly affected by eye movements, while voxels in ventral temporal areas are only weakly affected by eye movements. These results suggest that the ventral temporal visual areas contain a stable representation of the visual world that is invariant to eye movements made during natural vision.

  3. Immunological and pathological investigations in equine experimental uveitis.

    PubMed

    Simeonova, Galina P; Krastev, Svetozar Z; Simeonov, Radostin S

    2016-12-01

    The pathogenic mechanism of equine recurrent uveitis (ERU) is still poorly defined and many variations between experimental animal models and spontaneous disease exist. The aim of our study was to investigate if Th17 cell-mediated response plays role in the pathogenesis of the used experimental model in horses and to reveal its pathological findings. Experimental uveitis was induced in 6 healthy horses. The concentrations of retinal autoantigen CRALBP and IL-17 were measured using ELISA in aqueous humor and vitreous body of the 12 inflamed eyes as well as in 12 control non-inflamed eyes taken from 6 horses in slaughter house. After centrifugation of the two eye media, smears were prepared and cytological investigation was performed. Tissue specimens were taken from all eye globes and were submitted to histopathological investigation. CRALBP and IL-17 concentrations were significantly elevated in eye media of horses with experimental uveitis in comparison with controls. Cytological and histopathological findings corresponded to the changes characteristic of chronic immune-mediated inflammation with mononuclear cell infiltration of uvea, choroid, retina, and eye media as well as severe retinal destruction. Our study demonstrated the involvement of the retinal autoantigen CRALBP as well as IL-17 in the pathogenesis of experimental uveitis in horses. These findings suggests that this experimental uveitis in horses may serve as a suitable animal model for investigation of IL-17- mediated immune response during spontaneous autoimmune uveitis in horses as well as in humans.

  4. In vitro assessment of eye irritancy using the Reconstructed Human Corneal Epithelial SkinEthic HCE model: application to 435 substances from consumer products industry.

    PubMed

    Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques

    2010-03-01

    The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  5. Eyelid contour detection and tracking for startle research related eye-blink measurements from high-speed video records.

    PubMed

    Bernard, Florian; Deuter, Christian Eric; Gemmar, Peter; Schachinger, Hartmut

    2013-10-01

    Using the positions of the eyelids is an effective and contact-free way for the measurement of startle induced eye-blinks, which plays an important role in human psychophysiological research. To the best of our knowledge, no methods for an efficient detection and tracking of the exact eyelid contours in image sequences captured at high-speed exist that are conveniently usable by psychophysiological researchers. In this publication a semi-automatic model-based eyelid contour detection and tracking algorithm for the analysis of high-speed video recordings from an eye tracker is presented. As a large number of images have been acquired prior to method development it was important that our technique is able to deal with images that are recorded without any special parametrisation of the eye tracker. The method entails pupil detection, specular reflection removal and makes use of dynamic model adaption. In a proof-of-concept study we could achieve a correct detection rate of 90.6%. With this approach, we provide a feasible method to accurately assess eye-blinks from high-speed video recordings. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Clusterin Seals the Ocular Surface Barrier in Mouse Dry Eye

    PubMed Central

    Bauskar, Aditi; Mack, Wendy J.; Mauris, Jerome; Argüeso, Pablo; Heur, Martin; Nagel, Barbara A.; Kolar, Grant R.; Gleave, Martin E.; Nakamura, Takahiro; Kinoshita, Shigeru; Moradian-Oldak, Janet; Panjwani, Noorjahan; Pflugfelder, Stephen C.; Wilson, Mark R.; Fini, M. Elizabeth; Jeong, Shinwu

    2015-01-01

    Dry eye is a common disorder caused by inadequate hydration of the ocular surface that results in disruption of barrier function. The homeostatic protein clusterin (CLU) is prominent at fluid-tissue interfaces throughout the body. CLU levels are reduced at the ocular surface in human inflammatory disorders that manifest as severe dry eye, as well as in a preclinical mouse model for desiccating stress that mimics dry eye. Using this mouse model, we show here that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to the galectin LGALS3, a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. These findings define a fundamentally new mechanism for ocular surface protection and suggest CLU as a biotherapeutic for dry eye. PMID:26402857

  7. Clusterin Seals the Ocular Surface Barrier in Mouse Dry Eye.

    PubMed

    Bauskar, Aditi; Mack, Wendy J; Mauris, Jerome; Argüeso, Pablo; Heur, Martin; Nagel, Barbara A; Kolar, Grant R; Gleave, Martin E; Nakamura, Takahiro; Kinoshita, Shigeru; Moradian-Oldak, Janet; Panjwani, Noorjahan; Pflugfelder, Stephen C; Wilson, Mark R; Fini, M Elizabeth; Jeong, Shinwu

    2015-01-01

    Dry eye is a common disorder caused by inadequate hydration of the ocular surface that results in disruption of barrier function. The homeostatic protein clusterin (CLU) is prominent at fluid-tissue interfaces throughout the body. CLU levels are reduced at the ocular surface in human inflammatory disorders that manifest as severe dry eye, as well as in a preclinical mouse model for desiccating stress that mimics dry eye. Using this mouse model, we show here that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to the galectin LGALS3, a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. These findings define a fundamentally new mechanism for ocular surface protection and suggest CLU as a biotherapeutic for dry eye.

  8. Computer-based simulation of the Bielschowsky head-tilt test using the SEE++ software system.

    PubMed

    Kaltofen, Thomas; Buchberger, Michael; Priglinger, Siegfried

    2008-01-01

    Latest measurements of the vestibulo-ocular reflex (VOR) allowed the integration of the simulation of the Bielschowsky head-tilt test (BHTT) into the SEE++ software system. SEE++ realizes a biomechanical model of the human eye in order to simulate eye motility disorders and strabismus surgeries. With the addition of the BHTT it can now also be used for differential-diagnostic simulations of complex disorders (e.g., superior oblique palsies). In order to simulate the BHTT in SEE++, the user can freely choose the desired head-tilt angle from -45 degrees to +45 degrees. The chosen angle is shown in the 3D view with a human body model and is also used in the calculation of the Hess-Lancaster test. The integration of the BHTT offers an additional improvement of the possibilities for simulating eye motility disorders. Moreover, SEE++ allows the creation of a video of the "virtual patient" while tilting the head from one side to the other, which shows dynamic changes in the simulated Hess-diagrams. Comparisons of simulation results with patient-measured data showed a good correlation between the simulated and the measured data. Further comparisons with patient data are planned.

  9. Priorities and trends in the study of proteins in eye research, 1924–2014

    PubMed Central

    Semba, Richard D.; Lam, Maggie; Sun, Kai; Zhang, Pingbo; Schaumberg, Debra A.; Ferrucci, Luigi; Ping, Peipei; Van Eyk, Jennifer E.

    2015-01-01

    Purpose To identify the proteins that are relevant to eye research and develop assays for the study of a set of these proteins. Experimental Design We conducted a bibliometric analysis by merging gene lists for human and mouse from the National Center for Biotechnology Information FTP site and combining them with PubMed references that were retrieved with the search terms “eye”[MeSH Terms] OR “eye”[All Fields] OR “eyes”[All Fields]. Results For human and mouse eye studies, respectively, the total number of publications was 13,525 and 23,895, and the total number of proteins was 4,050 and 4,717. For proteins in human and mouse eye studies, respectively, 88.7% and 81.7% had five or fewer citations. The top fifty most intensively studied proteins for human and mouse eye studies were generally in the areas of photoreceptors and phototransduction, inflammation and angiogenesis, neurodevelopment, lens transparency, and cell cycle and cellular processes. We proposed selected reaction monitoring assays that were developed in silico for the top fifty most intensively studied proteins in human and mouse eye research. Conclusions and clinical relevance We conclude that scientists engaged in eye research tend to focus on the same proteins. Newer resources and tools in proteomics can expand the investigations to lesser-known proteins of the eye. PMID:26123431

  10. A technique of experimental and numerical analysis of influence of defects in the intraocular lens on the retinal image quality

    NASA Astrophysics Data System (ADS)

    Geniusz, Malwina; ZajÄ c, Marek

    2016-09-01

    Intraocular lens (IOL) is an artificial lens implanted into the eye in order to restore correct vision after the removal of natural lens cloudy due to cataract. The IOL prolonged stay in the eyeball causes the creation of different changes on the surface and inside the implant mainly in form of small-size local defects such as vacuoles and calcium deposites. Their presence worsens the imaging properties of the eye mainly due to occurence of scattered light thus deteriorating the vision quality of patients after cataract surgery. It is very difficult to study influence the effects of these changes on image quality in real patients. To avoid these difficulties two other possibilities were chosen: the analysis of the image obtained in an optomechanical eye model with artificially aged IOL as well as numerical calculation of the image characteristics while the eye lens is burdened with adequately modeled defects. In experiments the optomechanical model of an eye consisting of a glass "cornea", chamber filled with liquid where the IOL under investigation was inserted and a high resulution CCC detector serving as a "retina" was used. The Modulation Transfer Function (MTF) of such "eye" was evaluated on the basis of image of an edge. Experiments show that there is significant connection between ageing defects and decrease in MTF parameters. Numerical part was performed with a computer programme for optical imaging analysis (OpticStudio Professional, Zemax Professional from Radiant Zemax, LLC). On the basis of Atchison eye model with lens burdened with defects Modulation Transfer Functio was calculated. Particular parameters of defects used in a numerical model were based on own measurements. Numerical simulation also show significant connection between ageing defects and decrease of MTF parameters. With this technique the influence of types, density and distribution of local defect in the IOL on the retinal image quality can be evaluated quickly without the need of performing very difficult and even dangereous experiments on real human patients.

  11. A non-invasive method for studying an index of pupil diameter and visual performance in the rhesus monkey.

    PubMed

    Fairhall, Sarah J; Dickson, Carol A; Scott, Leah; Pearce, Peter C

    2006-04-01

    A non-invasive model has been developed to estimate gaze direction and relative pupil diameter, in minimally restrained rhesus monkeys, to investigate the effects of low doses of ocularly administered cholinergic compounds on visual performance. Animals were trained to co-operate with a novel device, which enabled eye movements to be recorded using modified human eye-tracking equipment, and to perform a task which determined visual threshold contrast. Responses were made by gaze transfer under twilight conditions. 4% w/v pilocarpine nitrate was studied to demonstrate the suitability of the model. Pilocarpine induced marked miosis for >3 h which was accompanied by a decrement in task performance. The method obviates the need for invasive surgery and, as the position of point of gaze can be approximately defined, the approach may have utility in other areas of research involving non-human primates.

  12. Verification of the lack of correlation between age and longitudinal chromatic aberrations of the human eye from the visible to the infrared

    PubMed Central

    Nakajima, Masashi; Hiraoka, Takahiro; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi

    2015-01-01

    Several researchers studied the longitudinal chromatic aberration (LCA) of the human eye and observed that it does not change due to age. We measured the LCA of 45 subjects’ normal right eyes at three distinct wavelengths (561, 690, and 840 nm) using a Hartmann–Shack wavefront aberrometer (HSWA) while consecutively switching between three light sources for wavefront sensing. We confirmed that the LCA of the human eye does not change due to age between 22 and 57 years. PMID:26203391

  13. Transcriptome analysis of Nautilus and pygmy squid developing eye provides insights in lens and eye evolution.

    PubMed

    Sousounis, Konstantinos; Ogura, Atsushi; Tsonis, Panagiotis A

    2013-01-01

    Coleoid cephalopods like squids have a camera-type eye similar to vertebrates. On the other hand, Nautilus (Nautiloids) has a pinhole eye that lacks lens and cornea. Since pygmy squid and Nautilus are closely related species they are excellent model organisms to study eye evolution. Having being able to collect Nautilus embryos, we employed next-generation RNA sequencing using Nautilus and pygmy squid developing eyes. Their transcriptomes were compared and analyzed. Enrichment analysis of Gene Ontology revealed that contigs related to nucleic acid binding were largely up-regulated in squid, while the ones related to metabolic processes and extracellular matrix-related genes were up-regulated in Nautilus. These differences are most likely correlated with the complexity of tissue organization in these species. Moreover, when the analysis focused on the eye-related contigs several interesting patterns emerged. First, contigs from both species related to eye tissue differentiation and morphogenesis as well as to cilia showed best hits with their Human counterparts, while contigs related to rabdomeric photoreceptors showed the best hit with their Drosophila counterparts. This bolsters the idea that eye morphogenesis genes have been generally conserved in evolution, and compliments other studies showing that genes involved in photoreceptor differentiation clearly follow the diversification of invertebrate (rabdomeric) and vertebrate (ciliated) photoreceptors. Interestingly some contigs showed as good a hit with Drosophila and Human homologues in Nautilus and squid samples. One of them, capt/CAP1, is known to be preferentially expressed in Drosophila developing eye and in vertebrate lens. Importantly our analysis also provided evidence of gene duplication and diversification of their function in both species. One of these genes is the Neurofibromatosis 1 (NF1/Nf1), which in mice has been implicated in lens formation, suggesting a hitherto unsuspected role in the evolution of the lens in molluscs.

  14. Transcriptome Analysis of Nautilus and Pygmy Squid Developing Eye Provides Insights in Lens and Eye Evolution

    PubMed Central

    Sousounis, Konstantinos; Ogura, Atsushi; Tsonis, Panagiotis A.

    2013-01-01

    Coleoid cephalopods like squids have a camera-type eye similar to vertebrates. On the other hand, Nautilus (Nautiloids) has a pinhole eye that lacks lens and cornea. Since pygmy squid and Nautilus are closely related species they are excellent model organisms to study eye evolution. Having being able to collect Nautilus embryos, we employed next-generation RNA sequencing using Nautilus and pygmy squid developing eyes. Their transcriptomes were compared and analyzed. Enrichment analysis of Gene Ontology revealed that contigs related to nucleic acid binding were largely up-regulated in squid, while the ones related to metabolic processes and extracellular matrix-related genes were up-regulated in Nautilus. These differences are most likely correlated with the complexity of tissue organization in these species. Moreover, when the analysis focused on the eye-related contigs several interesting patterns emerged. First, contigs from both species related to eye tissue differentiation and morphogenesis as well as to cilia showed best hits with their Human counterparts, while contigs related to rabdomeric photoreceptors showed the best hit with their Drosophila counterparts. This bolsters the idea that eye morphogenesis genes have been generally conserved in evolution, and compliments other studies showing that genes involved in photoreceptor differentiation clearly follow the diversification of invertebrate (rabdomeric) and vertebrate (ciliated) photoreceptors. Interestingly some contigs showed as good a hit with Drosophila and Human homologues in Nautilus and squid samples. One of them, capt/CAP1, is known to be preferentially expressed in Drosophila developing eye and in vertebrate lens. Importantly our analysis also provided evidence of gene duplication and diversification of their function in both species. One of these genes is the Neurofibromatosis 1 (NF1/Nf1), which in mice has been implicated in lens formation, suggesting a hitherto unsuspected role in the evolution of the lens in molluscs. PMID:24205087

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J; Barstow, Del R; Karakaya, Mahmut

    Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method usesmore » an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.« less

  16. Whole-eye transplantation: a look into the past and vision for the future

    PubMed Central

    Bourne, D; Li, Y; Komatsu, C; Miller, M R; Davidson, E H; He, L; Rosner, I A; Tang, H; Chen, W; Solari, M G; Schuman, J S; Washington, K M

    2017-01-01

    Blindness afflicts ~39 million people worldwide. Retinal ganglion cells are unable to regenerate, making this condition irreversible in many cases. Whole-eye transplantation (WET) provides the opportunity to replace diseased retinal ganglion cells, as well as the entire optical system and surrounding facial tissue, if necessary. Recent success in face transplantation demonstrates that this may be a promising treatment for what has been to this time an incurable condition. An animal model for WET must be established to further enhance our knowledge of nerve regeneration, immunosuppression, and technical aspects of surgery. A systematic review of the literature was performed to evaluate studies describing animal models for WET. Only articles in which the eye was completely enucleated and reimplanted were included. Study methods and results were compared. In the majority of published literature, WET can result in recovery of vision in cold-blooded vertebrates. There are a few instances in which mammalian WET models demonstrate survival of the transplanted tissue following neurovascular anastomosis and the ability to maintain brief electroretinogram activity in the new host. In this study we review in cold-blooded vertebrates and mammalian animal models for WET and discuss prospects for future research for translation to human eye transplantation. PMID:27983731

  17. Integral modeling of human eyes: from anatomy to visual response

    NASA Astrophysics Data System (ADS)

    Navarro, Rafael

    2006-02-01

    Three basic stages towards the global modeling of the eye are presented. In the first stage, an adequate choice of the basis geometrical model, general ellipsoid in this case, permits, to fit in a natural way the typical "melon" shape of the cornea with minimum complexity. In addition it facilitates to extract most of its optically relevant parameters, such as the position and orientation of it optical axis in the 3D space, the paraxial and overall refractive power, the amount and axis of astigmatism, etc. In the second level, this geometrical model, along with optical design and optimization tools, is applied to build customized optical models of individual eyes, able to reproduce the measured wave aberration with high fidelity. Finally, we put together a sequence of schematic, but functionally realistic models of the different stages of image acquisition, coding and analysis in the visual system, along with a probabilistic Bayesian maximum a posteriori identification approach. This permitted us to build a realistic simulation of the all the essential processes involved in a visual acuity clinical exam. It is remarkable that at all three levels, it has been possible for the models to predict the experimental data with high accuracy.

  18. Developmental validation of the IrisPlex system: determination of blue and brown iris colour for forensic intelligence.

    PubMed

    Walsh, Susan; Lindenbergh, Alexander; Zuniga, Sofia B; Sijen, Titia; de Knijff, Peter; Kayser, Manfred; Ballantyne, Kaye N

    2011-11-01

    The IrisPlex system consists of a highly sensitive multiplex genotyping assay together with a statistical prediction model, providing users with the ability to predict blue and brown human eye colour from DNA samples with over 90% precision. This 'DNA intelligence' system is expected to aid police investigations by providing phenotypic information on unknown individuals when conventional DNA profiling is not informative. Falling within the new area of forensic DNA phenotyping, this paper describes the developmental validation of the IrisPlex assay following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for the application of DNA-based eye colour prediction to forensic casework. The IrisPlex assay produces complete SNP genotypes with only 31pg of DNA, approximately six human diploid cell equivalents, and is therefore more sensitive than commercial STR kits currently used in forensics. Species testing revealed human and primate specificity for a complete SNP profile. The assay is capable of producing accurate results from simulated casework samples such as blood, semen, saliva, hair, and trace DNA samples, including extremely low quantity samples. Due to its design, it can also produce full profiles with highly degraded samples often found in forensic casework. Concordance testing between three independent laboratories displayed reproducible results of consistent levels on varying types of simulated casework samples. With such high levels of sensitivity, specificity, consistency and reliability, this genotyping assay, as a core part of the IrisPlex system, operates in accordance with SWGDAM guidelines. Furthermore, as we demonstrated previously, the IrisPlex eye colour prediction system provides reliable results without the need for knowledge on the bio-geographic ancestry of the sample donor. Hence, the IrisPlex system, with its model-based prediction probability estimation of blue and brown human eye colour, represents a useful tool for immediate application in accredited forensic laboratories, to be used for forensic intelligence in tracing unknown individuals from crime scene samples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-08-23

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.

  20. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model

    PubMed Central

    Kaluzhny, Yulia; Kandárová, Helena; d’Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-01-01

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492. PMID:26325674

  1. Analysis of the rdd locus in chicken: a model for human retinitis pigmentosa.

    PubMed

    Burt, David W; Morrice, David R; Lester, Douglas H; Robertson, Graeme W; Mohamed, Moin D; Simmons, Ian; Downey, Louise M; Thaung, Caroline; Bridges, Leslie R; Paton, Ian R; Gentle, Mike; Smith, Jacqueline; Hocking, Paul M; Inglehearn, Chris F

    2003-04-30

    To identify the locus responsible for the blind mutation rdd (retinal dysplasia and degeneration) in chickens and to further characterise the rdd phenotype. The eyes of blind and sighted birds were subjected to ophthalmic, morphometric and histopathological examination to confirm and extend published observations. Electroretinography was used to determine age of onset. Birds were crossed to create pedigrees suitable for genetic mapping. DNA samples were obtained and subjected to a linkage search. Measurement of IOP, axial length, corneal diameter, and eye weight revealed no gross morphological changes in the rdd eye. However, on ophthalmic examination, rdd homozygotes have a sluggish pupillary response, atrophic pecten, and widespread pigmentary disturbance that becomes more pronounced with age. Older birds also have posterior subcapsular cataracts. At three weeks of age, homozygotes have a flat ERG indicating severe loss of visual function. Pathological examination shows thinning of the RPE, ONL, photoreceptors and INL, and attenuation of the ganglion cell layer. From 77 classified backcross progeny, 39 birds were blind and 38 sighted. The rdd mutation was shown to be sex-linked and not autosomal as previously described. Linkage analysis mapped the rdd locus to a small region of the chicken Z chromosome with homologies to human chromosomes 5q and 9p. Ophthalmic, histopathologic, and electrophysiological observations suggest rdd is similar to human recessive retinitis pigmentosa. Linkage mapping places rdd in a region homologous to human chromosomes 9p and 5q. Candidate disease genes or loci include PDE6A, WGN1, and USH2C. This is the first use of genetic mapping in a chicken model of human disease.

  2. Ex vivo magnetic resonance imaging of crystalline lens dimensions in chicken.

    PubMed

    Tattersall, Rebecca J; Prashar, Ankush; Singh, Krish D; Tokarczuk, Pawel F; Erichsen, Jonathan T; Hocking, Paul M; Guggenheim, Jeremy A

    2010-02-02

    A reduction in the power of the crystalline lens during childhood is thought to be important in the emmetropization of the maturing eye. However, in humans and model organisms, little is known about the factors that determine the dimensions of the crystalline lens and in particular whether these different parameters (axial thickness, surface curvatures, equatorial diameter, and volume) are under a common source of control or regulated independently of other aspects of eye size and shape. Using chickens from a broiler-layer experimental cross as a model system, three-dimensional magnetic resonance imaging (MRI) scans were obtained at 115-microm isotropic resolution for one eye of 501 individuals aged 3-weeks old. After fixation with paraformaldehyde, the excised eyes were scanned overnight (16 h) in groups of 16 arranged in a 2x2x4 array. Lens dimensions were calculated from each image by fitting a three-dimensional mesh model to the lens, using the semi-automated analysis program mri3dX. The lens dimensions were compared to measures of eye and body size obtained in vivo using techniques that included keratometry and A-scan ultrasonography. A striking finding was that axial lens thickness measured using ex vivo MRI was only weakly correlated with lens thickness measured in vivo by ultrasonography (r=0.19, p<0.001). In addition, the MRI lens thickness estimates had a lower mean value and much higher variance. Indeed, about one-third of crystalline lenses showed a kidney-shaped appearance instead of the typical biconvex shape. Since repeat MRI scans of the same eye showed a high degree of reproducibility for the scanning and mri3dX analysis steps (the correlation in repeat lens thickness measurements was r=0.95, p<0.001) and a recent report has shown that paraformaldehyde fixation induces a loss of water from the human crystalline lens, it is likely that the tissue fixation step caused a variable degree of shrinkage and a change in shape to the lenses examined here. Despite this serious source of imprecision, we found significant correlations between lens volume and eye/body size (p<0.001) and between lens equatorial diameter and eye/body size (p<0.001) in these chickens. Our results suggest that certain aspects of lens size (specifically, lens volume and equatorial diameter) are controlled by factors that also regulate the size of the eye and body (presumably, predominantly genetic factors). However, since it has been shown previously that axial lens thickness is regulated almost independently of eye and body size, these results suggest that different systems might operate to control lens volume/diameter and lens thickness in normal chickens.

  3. Ex vivo magnetic resonance imaging of crystalline lens dimensions in chicken

    PubMed Central

    Tattersall, Rebecca J.; Prashar, Ankush; Singh, Krish D.; Tokarczuk, Pawel F.; Erichsen, Jonathan T.; Hocking, Paul M.

    2010-01-01

    Purpose A reduction in the power of the crystalline lens during childhood is thought to be important in the emmetropization of the maturing eye. However, in humans and model organisms, little is known about the factors that determine the dimensions of the crystalline lens and in particular whether these different parameters (axial thickness, surface curvatures, equatorial diameter, and volume) are under a common source of control or regulated independently of other aspects of eye size and shape. Methods Using chickens from a broiler-layer experimental cross as a model system, three-dimensional magnetic resonance imaging (MRI) scans were obtained at 115-µm isotropic resolution for one eye of 501 individuals aged 3-weeks old. After fixation with paraformaldehyde, the excised eyes were scanned overnight (16 h) in groups of 16 arranged in a 2×2×4 array. Lens dimensions were calculated from each image by fitting a three-dimensional mesh model to the lens, using the semi-automated analysis program mri3dX. The lens dimensions were compared to measures of eye and body size obtained in vivo using techniques that included keratometry and A-scan ultrasonography. Results A striking finding was that axial lens thickness measured using ex vivo MRI was only weakly correlated with lens thickness measured in vivo by ultrasonography (r=0.19, p<0.001). In addition, the MRI lens thickness estimates had a lower mean value and much higher variance. Indeed, about one-third of crystalline lenses showed a kidney-shaped appearance instead of the typical biconvex shape. Since repeat MRI scans of the same eye showed a high degree of reproducibility for the scanning and mri3dX analysis steps (the correlation in repeat lens thickness measurements was r=0.95, p<0.001) and a recent report has shown that paraformaldehyde fixation induces a loss of water from the human crystalline lens, it is likely that the tissue fixation step caused a variable degree of shrinkage and a change in shape to the lenses examined here. Despite this serious source of imprecision, we found significant correlations between lens volume and eye/body size (p<0.001) and between lens equatorial diameter and eye/body size (p<0.001) in these chickens. Conclusions Our results suggest that certain aspects of lens size (specifically, lens volume and equatorial diameter) are controlled by factors that also regulate the size of the eye and body (presumably, predominantly genetic factors). However, since it has been shown previously that axial lens thickness is regulated almost independently of eye and body size, these results suggest that different systems might operate to control lens volume/diameter and lens thickness in normal chickens. PMID:20142845

  4. Conserved genetic pathways associated with microphthalmia, anophthalmia, and coloboma

    PubMed Central

    Reis, Linda M.; Semina, Elena V.

    2016-01-01

    The human eye is a complex organ whose development requires extraordinary coordination of developmental processes. The conservation of ocular developmental steps in vertebrates suggests possible common genetic mechanisms. Genetic diseases involving the eye represent a leading cause of blindness in children and adults. During the last decades, there has been an exponential increase in genetic studies of ocular disorders. In this review, we summarize current success in identification of genes responsible for microphthalmia, anophthalmia and coloboma (MAC) phenotypes, which are associated with early defects in embryonic eye development. Studies in animal models for the orthologous genes identified overlapping phenotypes for most factors confirming the conservation of their function in vertebrate development. These animal models allow for further investigation of the mechanisms of MAC, integration of various identified genes into common developmental pathways and, finally, provide an avenue for the development and testing of therapeutic interventions. PMID:26046913

  5. Conserved genetic pathways associated with microphthalmia, anophthalmia, and coloboma.

    PubMed

    Reis, Linda M; Semina, Elena V

    2015-06-01

    The human eye is a complex organ whose development requires extraordinary coordination of developmental processes. The conservation of ocular developmental steps in vertebrates suggests possible common genetic mechanisms. Genetic diseases involving the eye represent a leading cause of blindness in children and adults. During the last decades, there has been an exponential increase in genetic studies of ocular disorders. In this review, we summarize current success in identification of genes responsible for microphthalmia, anophthalmia, and coloboma (MAC) phenotypes, which are associated with early defects in embryonic eye development. Studies in animal models for the orthologous genes identified overlapping phenotypes for most factors, confirming the conservation of their function in vertebrate development. These animal models allow for further investigation of the mechanisms of MAC, integration of various identified genes into common developmental pathways and finally, provide an avenue for the development and testing of therapeutic interventions. © 2015 Wiley Periodicals, Inc.

  6. Analysis of stress-strain state of a human eye by the method of elastotonometry after the surgical correction of hyperopia

    NASA Astrophysics Data System (ADS)

    Bauer, S. M.; Venatovskaya, L. A.

    2018-05-01

    The mathematical model of measuring of the intraocular pressure (IOP) by Maklakoff tonometer in the software package ANSYS, Inc. is presented. The dependence of the tonometric pressure on the weight of the tonometer before and after LASIK and Femto LASIK surgical corrections of hyperopia is analized. Cornea-scleral eye shell is modeled as two thin transversely isotropic joint spherical shells with different radii of curvature and biomechanical properties. To analyze the biomechanical state of the corneoscleral shell of the eye after the surgery the elastotonometry method is used. Firstly sequential measurements of intraocular pressure by Maklakoff tonometers weighting 5; 7.5; 10 and 15 g is carried out, then the dependence curve of tonometric IOP vs. tonometer weight is plotted and analyzed. The results of the calculations are compared with the clinical data.

  7. The role of systemic and topical fatty acids for dry eye treatment.

    PubMed

    Barabino, Stefano; Horwath-Winter, Jutta; Messmer, Elisabeth M; Rolando, Maurizio; Aragona, Pasquale; Kinoshita, Shigeru

    2017-11-01

    Dry eye is a prevalent condition and one of the main reasons for patients to seek ophthalmic medical care. A low systemic level of omega fatty acids is a risk factor for dry eye disease (DED). There are two groups of essential fatty acids (EFAs): the omega-6 (n-6) family and the omega-3 (n-3) family. Humans evolved on a diet in which the n-6:n-3 ratio was approximately 1:1, however the current Western diet tends to be deficient in n-3 EFAs and this ratio is typically much higher (approaching 17:1). The metabolism of EFAs generates four new families of local acting mediators: lipoxins, resolvins, protectins, and maresins. These molecules have anti-inflammatory and pro-resolution properties. We present a critical overview of animal model studies and human clinical trials that have shown that dietary modification and oral supplementation could be complementary therapeutic strategies for the treatment of dry eye. Furthermore, we discuss preliminary results of the topical application of n-3 and n-6 EFAs because these molecules may act as natural anti-inflammatory agents with positive changes of the entire ocular surface system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Numerical analysis of specific absorption rate in the human head due to a 13.56 MHz RFID-based intra-ocular pressure measurement system

    NASA Astrophysics Data System (ADS)

    Hirtl, Rene; Schmid, Gernot

    2013-09-01

    A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.

  9. Total Human Eye Allotransplantation: Developing Surgical Protocols for Donor and Recipient Procedures

    PubMed Central

    Davidson, Edward H.; Wang, Eric W.; Yu, Jenny Y.; Fernandez-Miranda, Juan C.; Wang, Dawn J.; Richards, Nikisha; Miller, Maxine; Schuman, Joel S.; Washington, Kia M.

    2017-01-01

    Background Vascularized composite allotransplantation of the eye is an appealing, novel method for reconstruction of the nonfunctioning eye. The authors’ group has established the first orthotopic model for eye transplantation in the rat. With advancements in immunomodulation strategies together with new therapies in neuroregeneration, parallel development of human surgical protocols is vital for ensuring momentum toward eye transplantation in actual patients. Methods Cadaveric donor tissue harvest (n = 8) was performed with orbital exenteration, combined open craniotomy, and endonasal approach to ligate the ophthalmic artery with a cuff of paraclival internal carotid artery, for transection of the optic nerve at the optic chiasm and transection of cranial nerves III to VI and the superior ophthalmic vein at the cavernous sinus. Candidate recipient vessels (superficial temporal/internal maxillary/facial artery and superficial temporal/facial vein) were exposed. Vein grafts were required for all anastomoses. Donor tissue was secured in recipient orbits followed by sequential venous and arterial anastomoses and nerve coaptation. Pedicle lengths and calibers were measured. All steps were timed, photographed, video recorded, and critically analyzed after each operative session. Results The technical feasibility of cadaveric donor procurement and transplantation to cadaveric recipient was established. Mean measurements included optic nerve length (39 mm) and caliber (5 mm), donor artery length (33 mm) and caliber (3 mm), and superior ophthalmic vein length (15 mm) and caliber (0.5 mm). Recipient superficial temporal, internal maxillary artery, and facial artery calibers were 0.8, 2, and 2 mm, respectively; and superior temporal and facial vein calibers were 0.8 and 2.5 mm, respectively. Conclusion This surgical protocol serves as a benchmark for optimization of technique, large-animal model development, and ultimately potentiating the possibility of vision restoration transplantation surgery. PMID:27879599

  10. The case from animal studies for balanced binocular treatment strategies for human amblyopia.

    PubMed

    Mitchell, Donald E; Duffy, Kevin R

    2014-03-01

    Although amblyopia typically manifests itself as a monocular condition, its origin has long been linked to unbalanced neural signals from the two eyes during early postnatal development, a view confirmed by studies conducted on animal models in the last 50 years. Despite recognition of its binocular origin, treatment of amblyopia continues to be dominated by a period of patching of the non-amblyopic eye that necessarily hinders binocular co-operation. This review summarizes evidence from three lines of investigation conducted on an animal model of deprivation amblyopia to support the thesis that treatment of amblyopia should instead focus upon procedures that promote and enhance binocular co-operation. First, experiments with mixed daily visual experience in which episodes of abnormal visual input were pitted against normal binocular exposure revealed that short exposures of the latter offset much longer periods of abnormal input to allow normal development of visual acuity in both eyes. Second, experiments on the use of part-time patching revealed that purposeful introduction of episodes of binocular vision each day could be very beneficial. Periods of binocular exposure that represented 30-50% of the daily visual exposure included with daily occlusion of the non-amblyopic could allow recovery of normal vision in the amblyopic eye. Third, very recent experiments demonstrate that a short 10 day period of total darkness can promote very fast and complete recovery of visual acuity in the amblyopic eye of kittens and may represent an example of a class of artificial environments that have similar beneficial effects. Finally, an approach is described to allow timing of events in kitten and human visual system development to be scaled to optimize the ages for therapeutic interventions. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  11. Gorillas with white sclera: A naturally occurring variation in a morphological trait linked to social cognitive functions.

    PubMed

    Mayhew, Jessica A; Gómez, Juan-Carlos

    2015-08-01

    Human eye morphology is considered unique among the primates in that humans possess larger width/height ratios (WHR), expose a greater amount of visible sclera (SSI; width of exposed eyeball/width of visible iris), and critically, have a white sclera due to a lack of pigmentation. White sclera in humans amplifies gaze direction, whereas the all-dark eyes of apes are hypothesized to conceal gaze from others. This study examines WHR and SSI in humans (N = 13) and gorillas (N = 85) engaged in direct and averted gazes and introduces a qualitative assessment of sclera color to evaluate variations in sclera pigmentation. The results confirm previous findings that humans possess a larger WHR than gorillas but indicate that humans and gorillas display similar amounts of visible sclera. Additionally, 72% (N = 124) of gorilla eyes in this sample deviated from the assumed all-dark eye condition. This questions whether gaze camouflage is the primary function of darkened sclera in non-human primates or whether other functional roles can be ascribed to the sclera, light or dark. We argue that white sclera evolved to amplify direct gazes in humans, which would have played a significant role in the development of ostensive communication, which is communication that both shows something and shows the intention to show something. We conclude that the horizontal elongation of the human eye, rather than sclera color, more reliably distinguishes human from great ape eyes, represented here by gorillas. © 2015 Wiley Periodicals, Inc.

  12. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovesdi, Casey Robert; Rice, Brandon Charles; Bower, Gordon Ross

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  13. In vitro cell culture models to study the corneal drug absorption.

    PubMed

    Reichl, Stephan; Kölln, Christian; Hahne, Matthias; Verstraelen, Jessica

    2011-05-01

    Many diseases of the anterior eye segment are treated using topically applied ophthalmic drugs. For these drugs, the cornea is the main barrier to reaching the interior of the eye. In vitro studies regarding transcorneal drug absorption are commonly performed using excised corneas from experimental animals. Due to several disadvantages and limitations of these animal experiments, establishing corneal cell culture models has been attempted as an alternative. This review summarizes the development of in vitro models based on corneal cell cultures for permeation studies during the last 20 years, starting with simple epithelial models and moving toward complex organotypical 3D corneal equivalents. Current human 3D corneal cell culture models have the potential to replace excised animal corneas in drug absorption studies. However, for widespread use, the contemporary validation of existent systems is required.

  14. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    NASA Astrophysics Data System (ADS)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  15. Human-Computer Interface Controlled by Horizontal Directional Eye Movements and Voluntary Blinks Using AC EOG Signals

    NASA Astrophysics Data System (ADS)

    Kajiwara, Yusuke; Murata, Hiroaki; Kimura, Haruhiko; Abe, Koji

    As a communication support tool for cases of amyotrophic lateral sclerosis (ALS), researches on eye gaze human-computer interfaces have been active. However, since voluntary and involuntary eye movements cannot be distinguished in the interfaces, their performance is still not sufficient for practical use. This paper presents a high performance human-computer interface system which unites high quality recognitions of horizontal directional eye movements and voluntary blinks. The experimental results have shown that the number of incorrect inputs is decreased by 35.1% in an existing system which equips recognitions of horizontal and vertical directional eye movements in addition to voluntary blinks and character inputs are speeded up by 17.4% from the existing system.

  16. System for assisted mobility using eye movements based on electrooculography.

    PubMed

    Barea, Rafael; Boquete, Luciano; Mazo, Manuel; López, Elena

    2002-12-01

    This paper describes an eye-control method based on electrooculography (EOG) to develop a system for assisted mobility. One of its most important features is its modularity, making it adaptable to the particular needs of each user according to the type and degree of handicap involved. An eye model based on electroculographic signal is proposed and its validity is studied. Several human-machine interfaces (HMI) based on EOG are commented, focusing our study on guiding and controlling a wheelchair for disabled people, where the control is actually effected by eye movements within the socket. Different techniques and guidance strategies are then shown with comments on the advantages and disadvantages of each one. The system consists of a standard electric wheelchair with an on-board computer, sensors and a graphic user interface run by the computer. On the other hand, this eye-control method can be applied to handle graphical interfaces, where the eye is used as a mouse computer. Results obtained show that this control technique could be useful in multiple applications, such as mobility and communication aid for handicapped persons.

  17. Determination of loss tangent of human tear film at 9.8 GHz

    NASA Astrophysics Data System (ADS)

    Bansal, Namita; Dhaliwal, A. S.; Mann, K. S.

    2015-08-01

    Basal (non-stimulated) tears that are produced by accessory lacrimal glands located in conjunctiva of human eye, form tear film which in turn keeps the eye moist and lubricate; nourishes the eye; protects the eye from dust, bacterial infection and shear forces generated during eye movements and blinking; and provides a refractive surface on the corneal epithelium. Film is known to contain water, mucin, lipids, lysozyme, glucose, urea, sodium etc. In present communication, loss tangent of human tear film has been determined at 9.8 GHz microwaves by employing cavity perturbation technique at a temperature of 37°C. The basal tears from a small population comprising six subjects were collected and average value of loss tangent is reported. Slater's technique was used to reduce the error caused in measuring the volume of sample. The determined values are useful to study the biological effects of microwaves on tear film as well as other parts of human eye such as eye lens and lens epithelial cells. To the best of author's knowledge, no such study is available in literature at any radio as well as microwave frequencies; therefore present determinations are first of its kind.

  18. A new cell-based method for assessing the eye irritation potential of chemicals: an alternative to the Draize test.

    PubMed

    Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong

    2012-07-20

    Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Visual optics: an engineering approach

    NASA Astrophysics Data System (ADS)

    Toadere, Florin

    2010-11-01

    The human eyes' visual system interprets the information from the visible light in order to build a representation of the world surrounding the body. It derives color by comparing the responses to light from the three types of photoreceptor cones in the eyes. These long medium and short cones are sensitive to blue, green and red portions of the visible spectrum. We simulate the color vision for the normal eyes. We see the effects of the dyes, filters, glasses and windows on color perception when the test image is illuminated with the D65 light sources. In addition to colors' perception, the human eyes can suffer from diseases and disorders. The eye can be seen as an optical instrument which has its own eye print. We present aspects of some nowadays methods and technologies which can capture and correct the human eyes' wavefront aberrations. We focus our attention to Siedel aberrations formula, Zenike polynomials, Shack-Hartmann Sensor, LASIK, interferograms fringes aberrations and Talbot effect.

  20. Light scatter on the surface of AcrySof intraocular lenses: part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes.

    PubMed

    Yaguchi, Shigeo; Nishihara, Hitoshi; Kambhiranond, Waraporn; Stanley, Daniel; Apple, David J

    2008-01-01

    To investigate the cause of light scatter measured on the surface of AcrySof intraocular lenses (Alcon Laboratories, Inc., Fort Worth, TX) retrieved from pseudophakic postmortem human eyes. Ten intraocular lenses (Alcon AcrySofModel MA60BM) were retrieved postmortem and analyzed for light scatter before and after removal of surface-bound biofilms. Six of the 10 lenses exhibited light scatter that was clearly above baseline levels. In these 6 lenses, both peak and average pixel density were reduced by approximately 80% after surface cleaning. The current study demonstrates that a coating deposited in vivo on the lens surface is responsible for the light scatter observed when incident light is applied.

  1. The Charles F. Prentice Award Lecture 2005: optics of the human eye: progress and problems.

    PubMed

    Charman, W Neil

    2006-06-01

    The history of measurements of ocular aberration is briefly reviewed and recent work using much-improved aberrometers and large samples of eyes is summarized. When on-axis, higher-order, monochromatic aberrations are averaged, undercorrected, positive, fourth-order spherical aberration dominates; other Zernike wavefront aberration coefficients have average values near zero. Individually, however, many eyes show substantial amounts of third-order and other fourth-order aberrations; the value of these varies idiosyncratically about zero. Most normal eyes show only small amounts of axial monochromatic aberration for photopic pupils up to around 3 mm; the limits to retinal image quality are then usually set by diffraction, uncorrected or imperfectly corrected spherocylindrical refractive error, accommodation error, and chromatic aberration. Longitudinal chromatic aberration varies very little across the population. With larger mesopic and scotopic pupils, monochromatic aberration plays a more important optical role, but overall visual performance is increasingly dominated by neural factors. Some remaining problems in measuring and modeling the eye's optical performance are discussed.

  2. Driver fatigue detection based on eye state.

    PubMed

    Lin, Lizong; Huang, Chao; Ni, Xiaopeng; Wang, Jiawen; Zhang, Hao; Li, Xiao; Qian, Zhiqin

    2015-01-01

    Nowadays, more and more traffic accidents occur because of driver fatigue. In order to reduce and prevent it, in this study, a calculation method using PERCLOS (percentage of eye closure time) parameter characteristics based on machine vision was developed. It determined whether a driver's eyes were in a fatigue state according to the PERCLOS value. The overall workflow solutions included face detection and tracking, detection and location of the human eye, human eye tracking, eye state recognition, and driver fatigue testing. The key aspects of the detection system incorporated the detection and location of human eyes and driver fatigue testing. The simplified method of measuring the PERCLOS value of the driver was to calculate the ratio of the eyes being open and closed with the total number of frames for a given period. If the eyes were closed more than the set threshold in the total number of frames, the system would alert the driver. Through many experiments, it was shown that besides the simple detection algorithm, the rapid computing speed, and the high detection and recognition accuracies of the system, the system was demonstrated to be in accord with the real-time requirements of a driver fatigue detection system.

  3. Chimpanzees and Humans Mimic Pupil-Size of Conspecifics

    PubMed Central

    Kret, Mariska E.; Tomonaga, Masaki; Matsuzawa, Tetsuro

    2014-01-01

    Group-living typically provides benefits to individual group members but also confers costs. To avoid incredulity and betrayal and allow trust and cooperation, individuals must understand the intentions and emotions of their group members. Humans attend to other's eyes and from gaze and pupil-size cues, infer information about the state of mind of the observed. In humans, pupil-size tends to mimic that of the observed. Here we tested whether pupil-mimicry exists in our closest relative, the chimpanzee (P. troglodytes). We conjectured that if pupil-mimicry has adaptive value, e.g. to promote swift communication of inner states and facilitate shared understanding and coordination, pupil-mimicry should emerge within but not across species. Pupillometry data was collected from human and chimpanzee subjects while they observed images of the eyes of both species with dilating/constricting pupils. Both species showed enhanced pupil-mimicry with members of their own species, with effects being strongest in humans and chimpanzee mothers. Pupil-mimicry may be deeply-rooted, but probably gained importance from the point in human evolution where the morphology of our eyes became more prominent. Humans' white sclera surrounding the iris, and the fine muscles around their eyes facilitate non-verbal communication via eye signals. PMID:25140998

  4. Is orbital volume associated with eyeball and visual cortex volume in humans?

    PubMed

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.

  5. Is orbital volume associated with eyeball and visual cortex volume in humans?

    PubMed Central

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    Background In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. Aim To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Subjects & Methods Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (N=88), and brain and visual cortex (N=99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. Results A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes, (iii) different visual cortical areas, independently of overall brain volume. Conclusion In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices. PMID:23879766

  6. Can human eyes prevent perceptual narrowing for monkey faces in human infants?

    PubMed

    Damon, Fabrice; Bayet, Laurie; Quinn, Paul C; Hillairet de Boisferon, Anne; Méary, David; Dupierrix, Eve; Lee, Kang; Pascalis, Olivier

    2015-07-01

    Perceptual narrowing has been observed in human infants for monkey faces: 6-month-olds can discriminate between them, whereas older infants from 9 months of age display difficulty discriminating between them. The difficulty infants from 9 months have processing monkey faces has not been clearly identified. It could be due to the structural characteristics of monkey faces, particularly the key facial features that differ from human faces. The current study aimed to investigate whether the information conveyed by the eyes is of importance. We examined whether the presence of Caucasian human eyes in monkey faces allows recognition to be maintained in 6-month-olds and facilitates recognition in 9- and 12-month-olds. Our results revealed that the presence of human eyes in monkey faces maintains recognition for those faces at 6 months of age and partially facilitates recognition of those faces at 9 months of age, but not at 12 months of age. The findings are interpreted in the context of perceptual narrowing and suggest that the attenuation of processing of other-species faces is not reversed by the presence of human eyes. © 2015 Wiley Periodicals, Inc.

  7. Evaluation of ocular irritancy of coal-tar dyes used in cosmetics employing reconstructed human cornea-like epithelium and short time exposure tests.

    PubMed

    Lee, Miri; Nam, Ki Taek; Kim, Jungah; Lim, Song E; Yeon, Sang Hyeon; Lee, Buhyun; Lee, Joo Young; Lim, Kyung-Min

    2017-10-01

    Coal-tar dyes in cosmetics may elicit adverse effects in the skin and eyes. Countries, like the US, have banned the use of coal-tar dyes in cosmetics for the eye area due to the potential for ocular irritation. We evaluated the eye irritation potential of 15 coal-tar dyes permitted as cosmetic ingredients in reconstructed human cornea-like epithelium (RhCEs [EpiOcular™ and MCTT HCE™]) tests and the short time exposure (STE) test. Eosin YS, phloxine B, tetrachlorotetrabromofluorescein, and tetrabromofluorescein were identified as irritants in RhCEs; dibromofluorescein and uranine yielded discrepant results. STE enabled further classification in accordance with the UN Globally Harmonized System of Classification and Labelling of Chemicals, as follows: eosin YS as Cat 2; phloxine B, Cat 1; and tetrachlorotetrabromofluorescein and tetrabromofluorescein, Cat 1/2. STE indicated dibromofluorescein (irritant in EpiOcular™) and uranine (irritant in MCTT HCE™) as No Cat, resulting in the classification of "No prediction can be made." based on bottom-up approach with each model. These results demonstrated that in vitro eye irritation tests can be utilized to evaluate the potential ocular irritancy of cosmetic ingredients and provide significant evidence with which to determine whether precautions should be given for the use of coal-tar dyes in cosmetics or other substances applied to the eye area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. How virtual reality works: illusions of vision in "real" and virtual environments

    NASA Astrophysics Data System (ADS)

    Stark, Lawrence W.

    1995-04-01

    Visual illusions abound in normal vision--illusions of clarity and completeness, of continuity in time and space, of presence and vivacity--and are part and parcel of the visual world inwhich we live. These illusions are discussed in terms of the human visual system, with its high- resolution fovea, moved from point to point in the visual scene by rapid saccadic eye movements (EMs). This sampling of visual information is supplemented by a low-resolution, wide peripheral field of view, especially sensitive to motion. Cognitive-spatial models controlling perception, imagery, and 'seeing,' also control the EMs that shift the fovea in the Scanpath mode. These illusions provide for presence, the sense off being within an environment. They equally well lead to 'Telepresence,' the sense of being within a virtual display, especially if the operator is intensely interacting within an eye-hand and head-eye human-machine interface that provides for congruent visual and motor frames of reference. Interaction, immersion, and interest compel telepresence; intuitive functioning and engineered information flows can optimize human adaptation to the artificial new world of virtual reality, as virtual reality expands into entertainment, simulation, telerobotics, and scientific visualization and other professional work.

  9. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    NASA Astrophysics Data System (ADS)

    Nogueira, P.; Zankl, M.; Schlattl, H.; Vaz, P.

    2011-11-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation—the germinative cells—absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  10. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    PubMed

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  11. The µ-opioid system promotes visual attention to faces and eyes.

    PubMed

    Chelnokova, Olga; Laeng, Bruno; Løseth, Guro; Eikemo, Marie; Willoch, Frode; Leknes, Siri

    2016-12-01

    Paying attention to others' faces and eyes is a cornerstone of human social behavior. The µ-opioid receptor (MOR) system, central to social reward-processing in rodents and primates, has been proposed to mediate the capacity for affiliative reward in humans. We assessed the role of the human MOR system in visual exploration of faces and eyes of conspecifics. Thirty healthy males received a novel, bidirectional battery of psychopharmacological treatment (an MOR agonist, a non-selective opioid antagonist, or placebo, on three separate days). Eye-movements were recorded while participants viewed facial photographs. We predicted that the MOR system would promote visual exploration of faces, and hypothesized that MOR agonism would increase, whereas antagonism decrease overt attention to the information-rich eye region. The expected linear effect of MOR manipulation on visual attention to the stimuli was observed, such that MOR agonism increased while antagonism decreased visual exploration of faces and overt attention to the eyes. The observed effects suggest that the human MOR system promotes overt visual attention to socially significant cues, in line with theories linking reward value to gaze control and target selection. Enhanced attention to others' faces and eyes represents a putative behavioral mechanism through which the human MOR system promotes social interest. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  12. Eye Contact Is Crucial for Referential Communication in Pet Dogs.

    PubMed

    Savalli, Carine; Resende, Briseida; Gaunet, Florence

    2016-01-01

    Dogs discriminate human direction of attention cues, such as body, gaze, head and eye orientation, in several circumstances. Eye contact particularly seems to provide information on human readiness to communicate; when there is such an ostensive cue, dogs tend to follow human communicative gestures more often. However, little is known about how such cues influence the production of communicative signals (e.g. gaze alternation and sustained gaze) in dogs. In the current study, in order to get an unreachable food, dogs needed to communicate with their owners in several conditions that differ according to the direction of owners' visual cues, namely gaze, head, eyes, and availability to make eye contact. Results provided evidence that pet dogs did not rely on details of owners' direction of visual attention. Instead, they relied on the whole combination of visual cues and especially on the owners' availability to make eye contact. Dogs increased visual communicative behaviors when they established eye contact with their owners, a different strategy compared to apes and baboons, that intensify vocalizations and gestures when human is not visually attending. The difference in strategy is possibly due to distinct status: domesticated vs wild. Results are discussed taking into account the ecological relevance of the task since pet dogs live in human environment and face similar situations on a daily basis during their lives.

  13. New developments in ophthalmic applications of ultrafast lasers

    NASA Astrophysics Data System (ADS)

    Spooner, Greg J. R.; Juhasz, Tibor; Ratkay-Traub, Imola; Djotyan, Gagik P.; Horvath, Christopher; Sacks, Zachary S.; Marre, Gabrielle; Miller, Doug L.; Williams, A. R.; Kurtz, Ron M.

    2000-05-01

    The eye is potentially an ideal target for high precision surgical procedures utilizing ultrafast lasers. We present progress on corneal applications now being tested in humans and proof of concept ex vivo demonstrations of new applications in the sclera and lens. Two corneal refractive procedures were tested in partially sighted human eyes: creation of corneal flaps prior to excimer ablation (Femto- LASIK) and creation of corneal channels and entry cuts for placement of intracorneal ring segments (Femto-ICRS). For both procedures, results were comparable to standard treatments, with the potential for improved safety, accuracy and reproducibility. For scleral applications, we evaluated the potential of femtosecond laser glaucoma surgery by demonstrating resections in ex vivo human sclera using dehydrating agents to induce tissue transparency. For lens applications, we demonstrate in an ex vivo model the use of photodisruptively-nucleated ultrasonic cavitation for local and non-invasive tissue interaction.

  14. Ultrathin flexible piezoelectric sensors for monitoring eye fatigue

    NASA Astrophysics Data System (ADS)

    Lü, Chaofeng; Wu, Shuang; Lu, Bingwei; Zhang, Yangyang; Du, Yangkun; Feng, Xue

    2018-02-01

    Eye fatigue is a symptom induced by long-term work of both eyes and brains. Without proper treatment, eye fatigue may incur serious problems. Current studies on detecting eye fatigue mainly focus on computer vision detect technology which can be very unreliable due to occasional bad visual conditions. As a solution, we proposed a wearable conformal in vivo eye fatigue monitoring sensor that contains an array of piezoelectric nanoribbons integrated on an ultrathin flexible substrate. By detecting strains on the skin of eyelid, the sensors may collect information about eye blinking, and, therefore, reveal human’s fatigue state. We first report the design and fabrication of the piezoelectric sensor and experimental characterization of voltage responses of the piezoelectric sensors. Under bending stress, the output voltage curves yield key information about the motion of human eyelid. We also develop a theoretical model to reveal the underlying mechanism of detecting eyelid motion. Both mechanical load test and in vivo test are conducted to convince the working performance of the sensors. With satisfied durability and high sensitivity, this sensor may efficiently detect abnormal eyelid motions, such as overlong closure, high blinking frequency, low closing speed and weak gazing strength, and may hopefully provide feedback for assessing eye fatigue in time so that unexpected situations can be prevented.

  15. Oculomatic: High speed, reliable, and accurate open-source eye tracking for humans and non-human primates.

    PubMed

    Zimmermann, Jan; Vazquez, Yuriria; Glimcher, Paul W; Pesaran, Bijan; Louie, Kenway

    2016-09-01

    Video-based noninvasive eye trackers are an extremely useful tool for many areas of research. Many open-source eye trackers are available but current open-source systems are not designed to track eye movements with the temporal resolution required to investigate the mechanisms of oculomotor behavior. Commercial systems are available but employ closed source hardware and software and are relatively expensive, limiting wide-spread use. Here we present Oculomatic, an open-source software and modular hardware solution to eye tracking for use in humans and non-human primates. Oculomatic features high temporal resolution (up to 600Hz), real-time eye tracking with high spatial accuracy (<0.5°), and low system latency (∼1.8ms, 0.32ms STD) at a relatively low-cost. Oculomatic compares favorably to our existing scleral search-coil system while being fully non invasive. We propose that Oculomatic can support a wide range of research into the properties and neural mechanisms of oculomotor behavior. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.

    PubMed

    Chang, David F; Mamalis, Nick; Werner, Liliana

    2016-02-01

    To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory infiltrates. Precision pulse capsulotomy is a new method to automate consistent creation of a perfectly circular anterior capsulotomy with a disposable handheld instrument that can be used in the normal phacoemulsification surgical sequence. Compared with CCC in fellow rabbit eyes, PPC was equally safe and showed no greater zonular stress compared with CCC in human cadaver eyes. Human cadaver eye SEM showed a much smoother capsulotomy edge compared to those produced by femtosecond laser. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Contribution of Spaceflight Environmental Factors to Vision Risks

    NASA Technical Reports Server (NTRS)

    Zanello, Susana B.

    2011-01-01

    The risk of visual impairment and elevated intracranial pressure as a result of low-earth orbit microgravity exposure has directed our attention and research efforts to the eye. While the alterations observed in astronauts returning from long duration missions include vision and neuroanatomical changes observed by non-invasive methods, other effects and subsequent tissue responses at the molecular and cellular level can only be studied by accessing the tissue itself. As a result of this need, several studies are currently taking place within the Human and Health Countermeasures Element (HHC) that use animal models for eye research. The rodent eye has many similarities to the human eye, and both rats and mice have historically been used as models of human eye disease, aiding in the identification of the disease genes, elucidation of mechanisms of disease, as well as in the assessment of therapeutic treatments. These studies attempt to answer two central questions in the etiology of possible vision alterations in the environment of space exploration missions. The first is: what effects and response mechanisms take place in the different eye structures at the cellular and molecular level? The second question is directed to elucidate the contribution of the various environmental stressors (radiation, nutrition, fluid shift) to these effects. Collaborative approaches with internal and external investigators have allowed performing these studies in a most cost-effective fashion, providing preliminary data and laying the bases for testing further hypotheses in future and specifically designed animal experiments. From a study centered on the radioadaptive response in mice, we have learned that the retina responds to low and high dose gamma radiation by elevating antioxidant-related genes at early time points (4hrs) and that this response returns to control levels after 1 day post-irradiation. We are expanding this research with another collaborative study that investigates the combined effects of radiation exposure and iron overload on sensitivity to radiation injury in rat eyes. All main eye structures will be analyzed in this study: retina, lens and cornea. A study in collaboration with the Space Human Factors and Habitability Element (SHFH) investigates the effects of lunar dust exposure on the rat cornea. It is anticipated that common underlying oxidative stress mechanisms of damage may be observed as a result of these three stressors: radiation, nutritional iron and lunar dust. The contribution of fluid shift is addressed by a study using rats subjected to hindlimb suspension. The hypothesis to be tested in this study is that the mechanical stress imparted by the pressure differential across the optic disc and lamina cribosa will impact oxygenation (therefore causing oxidative stress and hypoxia) and cell survival. This study also includes the assessment of two nutritional antioxidant countermeasures: epigallocatechin gallate (green tea) and resveratrol. Finally, as a result of two successful tissue sharing efforts, we are proceeding with the analysis of eye samples of mice aboard two shuttle missions: STS-133 and STS-135. Results from the STS-133 study are presented in an independent abstract. Briefly, the results show that spaceflight represents a source of environmental stress that directly translates into oxidative and cellular stress in the retina. Similar analysis is also planned for the cornea. These samples add large value to our current vision research as they provide data on the direct effects of low-earth orbit spaceflight on eye structures and physiology.

  18. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction.

    PubMed

    Xu, Tian Linger; Zhang, Hui; Yu, Chen

    2016-05-01

    We focus on a fundamental looking behavior in human-robot interactions - gazing at each other's face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user's face as a response to the human's gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot's gaze toward the human partner's face in real time and then analyzed the human's gaze behavior as a response to the robot's gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot's face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained.

  19. Binocular combination in abnormal binocular vision

    PubMed Central

    Ding, Jian; Klein, Stanley A.; Levi, Dennis M.

    2013-01-01

    We investigated suprathreshold binocular combination in humans with abnormal binocular visual experience early in life. In the first experiment we presented the two eyes with equal but opposite phase shifted sine waves and measured the perceived phase of the cyclopean sine wave. Normal observers have balanced vision between the two eyes when the two eyes' images have equal contrast (i.e., both eyes contribute equally to the perceived image and perceived phase = 0°). However, in observers with strabismus and/or amblyopia, balanced vision requires a higher contrast image in the nondominant eye (NDE) than the dominant eye (DE). This asymmetry between the two eyes is larger than predicted from the contrast sensitivities or monocular perceived contrast of the two eyes and is dependent on contrast and spatial frequency: more asymmetric with higher contrast and/or spatial frequency. Our results also revealed a surprising NDE-to-DE enhancement in some of our abnormal observers. This enhancement is not evident in normal vision because it is normally masked by interocular suppression. However, in these abnormal observers the NDE-to-DE suppression was weak or absent. In the second experiment, we used the identical stimuli to measure the perceived contrast of a cyclopean grating by matching the binocular combined contrast to a standard contrast presented to the DE. These measures provide strong constraints for model fitting. We found asymmetric interocular interactions in binocular contrast perception, which was dependent on both contrast and spatial frequency in the same way as in phase perception. By introducing asymmetric parameters to the modified Ding-Sperling model including interocular contrast gain enhancement, we succeeded in accounting for both binocular combined phase and contrast simultaneously. Adding binocular contrast gain control to the modified Ding-Sperling model enabled us to predict the results of dichoptic and binocular contrast discrimination experiments and provides new insights into the mechanisms of abnormal binocular vision. PMID:23397039

  20. Binocular combination in abnormal binocular vision.

    PubMed

    Ding, Jian; Klein, Stanley A; Levi, Dennis M

    2013-02-08

    We investigated suprathreshold binocular combination in humans with abnormal binocular visual experience early in life. In the first experiment we presented the two eyes with equal but opposite phase shifted sine waves and measured the perceived phase of the cyclopean sine wave. Normal observers have balanced vision between the two eyes when the two eyes' images have equal contrast (i.e., both eyes contribute equally to the perceived image and perceived phase = 0°). However, in observers with strabismus and/or amblyopia, balanced vision requires a higher contrast image in the nondominant eye (NDE) than the dominant eye (DE). This asymmetry between the two eyes is larger than predicted from the contrast sensitivities or monocular perceived contrast of the two eyes and is dependent on contrast and spatial frequency: more asymmetric with higher contrast and/or spatial frequency. Our results also revealed a surprising NDE-to-DE enhancement in some of our abnormal observers. This enhancement is not evident in normal vision because it is normally masked by interocular suppression. However, in these abnormal observers the NDE-to-DE suppression was weak or absent. In the second experiment, we used the identical stimuli to measure the perceived contrast of a cyclopean grating by matching the binocular combined contrast to a standard contrast presented to the DE. These measures provide strong constraints for model fitting. We found asymmetric interocular interactions in binocular contrast perception, which was dependent on both contrast and spatial frequency in the same way as in phase perception. By introducing asymmetric parameters to the modified Ding-Sperling model including interocular contrast gain enhancement, we succeeded in accounting for both binocular combined phase and contrast simultaneously. Adding binocular contrast gain control to the modified Ding-Sperling model enabled us to predict the results of dichoptic and binocular contrast discrimination experiments and provides new insights into the mechanisms of abnormal binocular vision.

  1. Cue-dependent memory-based smooth-pursuit in normal human subjects: importance of extra-retinal mechanisms for initial pursuit.

    PubMed

    Ito, Norie; Barnes, Graham R; Fukushima, Junko; Fukushima, Kikuro; Warabi, Tateo

    2013-08-01

    Using a cue-dependent memory-based smooth-pursuit task previously applied to monkeys, we examined the effects of visual motion-memory on smooth-pursuit eye movements in normal human subjects and compared the results with those of the trained monkeys. These results were also compared with those during simple ramp-pursuit that did not require visual motion-memory. During memory-based pursuit, all subjects exhibited virtually no errors in either pursuit-direction or go/no-go selection. Tracking eye movements of humans and monkeys were similar in the two tasks, but tracking eye movements were different between the two tasks; latencies of the pursuit and corrective saccades were prolonged, initial pursuit eye velocity and acceleration were lower, peak velocities were lower, and time to reach peak velocities lengthened during memory-based pursuit. These characteristics were similar to anticipatory pursuit initiated by extra-retinal components during the initial extinction task of Barnes and Collins (J Neurophysiol 100:1135-1146, 2008b). We suggest that the differences between the two tasks reflect differences between the contribution of extra-retinal and retinal components. This interpretation is supported by two further studies: (1) during popping out of the correct spot to enhance retinal image-motion inputs during memory-based pursuit, pursuit eye velocities approached those during simple ramp-pursuit, and (2) during initial blanking of spot motion during memory-based pursuit, pursuit components appeared in the correct direction. Our results showed the importance of extra-retinal mechanisms for initial pursuit during memory-based pursuit, which include priming effects and extra-retinal drive components. Comparison with monkey studies on neuronal responses and model analysis suggested possible pathways for the extra-retinal mechanisms.

  2. Comparison of parameters affecting GNP-loaded choroidal melanoma dosimetry; Monte Carlo study

    NASA Astrophysics Data System (ADS)

    Sharabiani, Marjan; Asadi, Somayeh; Barghi, Amir Rahnamai; Vaezzadeh, Mehdi

    2018-04-01

    The current study reports the results of tumor dosimetry in the presence of gold nanoparticles (GNPs) with different sizes and concentrations. Due to limited number of works carried out on the brachytherapy of choroidal melanoma in combination with GNPs, this study was performed to determine the optimum size and concentration for GNPs which contributes the highest dose deposition in tumor region, using two phantom test cases namely water phantom and a full Monte Carlo model of human eye. Both water and human eye phantoms were simulated with MCNP5 code. Tumor dosimetry was performed for a typical point photon source with an energy of 0.38 MeV as a high energy source and 103Pd brachytherapy source with an average energy of 0.021 MeV as a low energy source in water phantom and eye phantom respectively. Such a dosimetry was done for different sizes and concentrations of GNPs. For all of the diameters, increase in concentration of GNPs resulted in an increase in dose deposited in the region of interest. In a certain concentration, GNPs with larger diameters contributed more dose to the tumor region, which was more pronounced using eye phantom. 100 nm was reported as the optimum size in order to achieve the highest energy deposition within the target. This work investigated the optimum parameters affecting macroscopic dose enhancement in GNP-aided brachytherapy of choroidal melanoma. The current work also had implications on using low energy photon sources in the presence of GNPs to acquire the highest dose enhancement. This study is conducted through four different sizes and concentrations of GNPs. Considering the sensitivity of human eye tissue, in order to report the precise optimum parameters affecting radiosensitivity, a comprehensive study on a wide range of sizes and concentrations are required.

  3. Biobanking of Human Retinas: The Next Big Leap for Eye Banks?

    PubMed Central

    Lužnik, Zala; Parekh, Mohit; Bertolin, Marina; Griffoni, Carlo; Ponzin, Diego

    2015-01-01

    Summary Retinal degenerative diseases are one of the main clinical causes of incurable and severe visional impairment. Thus, extensive research effort is put into the development of new causal therapeutic options. Promisingly, a number of studies showed regenerative capacity in specific retinal regions (the ciliary epithelium, retinal pigmented epithelium, iris, and Müller glia cells). However, most recent research studies are based on animal models or in vitro cultured cells, probably because of the limited availability of human posterior eye tissues (vitreous, retina, and choroid). To address this, we showed in our previous reports that eye banks with large numbers of globes collected yearly could set up biorepositories/biobanks where these precious tissues are isolated, quality controlled, and finally stored for scientists and clinicians wanting to access human tissues and test their own hypotheses. These precious human posterior eye tissues could be used for further research purposes, epidemiological studies, and target validation of newly developed drugs. In addition, this could be a promising and challenging option to retrieve potential retinal stem and progenitor cells from different parts of the retina and could be a breakthrough in the future delivery of ex vivo prepared customized (histocompatible) retinal tissue on scaffolds for transplantation purposes. In this Perspective, we will consider how the biorepositories could influence the future strategies for retinal stem cell therapies. Significance Retinal degenerative diseases are one of the main causes of severe vision impairment and regenerative medicine is attracting much attention as a potential therapy. Although highly desirable, the reactivation and proliferation of endogenous stem cells in vivo is not sufficient to generate enough cells to restore visual function after retinal injury. Thus, the replacement of exogenously derived normal donor cells is a promising solution. The challenge is to develop therapies with sufficient amounts of cells being harvested or expanded from donor tissues. Eye banks could overcome this issue by harvesting endogenous adult retinal stem cells from different donors. PMID:26032747

  4. Experimental studies on nonpenetrating filtration surgery using the CO2 laser.

    PubMed

    Assia, Ehud I; Rotenstreich, Yigal; Barequet, Irina S; Apple, David J; Rosner, Mordechai; Belkin, Michael

    2007-06-01

    This study evaluated the use of a CO2 laser for performing deep sclerectomy in nonpenetrating filtration surgery. Three experimental models were performed: enucleated sheep and cow eyes (n=18) to determine optimal irradiation parameters, live rabbit eyes (n=20) to test feasibility, and cadaver eyes (40 procedures in 20 eyes) to study effects in human eyes tissue. After a half-thickness scleral flap was created, deep sclerectomy was performed by CO2 laser applications on the scleral bed down to the trabeculo-Descemet's membrane. Fluid percolation was repeatedly achieved without penetration in sheep and cow eyes using scanned laser energy of 5-10 W at a pulse duration of 200 micros and a working distance of 35 cm. In live rabbits, deep sclerectomy was achieved without perforation in 19/20 eyes. Intraocular pressure was significantly decreased on the first postoperative day (10.3+/-5.1 mmHg lower, on average, than in the nonoperated fellow eye; P<0.001), and this persisted for 21 days. Operations on all cadaver eyes resulted in effective fluid percolation. Penetration of the scleral wall occurred in five cases only after repeated laser applications with high energy. Histologically, a thin sclerocorneal intact wall was demonstrated at the sclerectomy bed. Collateral tissue damage did not extend beyond 100 microm, and adjacent structures remained unharmed. CO2 laser-assisted deep sclerectomy is a feasible and apparently safe procedure.

  5. Molecular Diagnosis of Human Taenia martis Eye Infection

    PubMed Central

    Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis

    2016-01-01

    Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. PMID:26928837

  6. Expression of classical components of the renin-angiotensin system in the human eye.

    PubMed

    White, Andrew J R; Cheruvu, Sarat C; Sarris, Maria; Liyanage, Surabhi S; Lumbers, Eugenie; Chui, Jeanie; Wakefield, Denis; McCluskey, Peter J

    2015-03-01

    The purpose of this study was to determine the relative expression of clinically-relevant components of the renin-angiotensin system (RAS) in the adult human eye. We obtained 14 post-mortem enucleated human eyes from patients whom had no history of inflammatory ocular disease nor pre-mortem ocular infection. We determined the gene expression for prorenin, renin, prorenin receptor, angiotensin-converting enzyme, angiotensinogen and angiotensin II Type 1 receptor, on tissue sections and in cultured human primary retinal pigment epithelial and iris pigment epithelial (RPE/IPE) cell lines, using both qualitative and quantitative reverse transcription polymerase chain reaction (RT-PCR). Protein expression was studied using indirect immunofluorescence (IF). Almost all components of the classical RAS were found at high levels, at both the transcript and protein level, in the eyes' uvea and retina; and at lower levels in the cornea, conjunctiva and sclera. There was a much lower level of expression in the reference cultured RPE/IPE cells lines. This study describes the distribution of RAS in the normal adult human eye and demonstrates the existence of an independent ocular RAS, with uveal and retinal tissues showing the highest expression of RAS components. These preliminary findings provide scope for examination of additional components of this system in the human eye, as well as possible differential expression under pathological conditions. © The Author(s) 2014.

  7. Human eyeball model reconstruction and quantitative analysis.

    PubMed

    Xing, Qi; Wei, Qi

    2014-01-01

    Determining shape of the eyeball is important to diagnose eyeball disease like myopia. In this paper, we present an automatic approach to precisely reconstruct three dimensional geometric shape of eyeball from MR Images. The model development pipeline involved image segmentation, registration, B-Spline surface fitting and subdivision surface fitting, neither of which required manual interaction. From the high resolution resultant models, geometric characteristics of the eyeball can be accurately quantified and analyzed. In addition to the eight metrics commonly used by existing studies, we proposed two novel metrics, Gaussian Curvature Analysis and Sphere Distance Deviation, to quantify the cornea shape and the whole eyeball surface respectively. The experiment results showed that the reconstructed eyeball models accurately represent the complex morphology of the eye. The ten metrics parameterize the eyeball among different subjects, which can potentially be used for eye disease diagnosis.

  8. Magnetic resonance imaging study of eye congenital birth defects in mouse model

    PubMed Central

    Tucker, Zachary; Mongan, Maureen; Meng, Qinghang; Xia, Ying

    2017-01-01

    Purpose Embryonic eyelid closure is a well-documented morphogenetic episode in mammalian eye development. Detection of eyelid closure defect in humans is a major challenge because eyelid closure and reopen occur entirely in utero. As a consequence, congenital eye defects that are associated with failure of embryonic eyelid closure remain unknown. To fill the gap, we developed a mouse model of defective eyelid closure. This preliminary work demonstrates that the magnetic resonance imaging (MRI) approach can be used for the detection of extraocular muscle abnormalities in the mouse model. Methods Mice with either normal (Map3k1+/−) or defective (Map3k1−/−) embryonic eyelid closure were used in this study. Images of the extraocular muscles were obtained with a 9.4 T high resolution microimaging MRI system. The extraocular muscles were identified, segmented, and measured in each imaging slice using an in-house program. Results In agreement with histological findings, the imaging data show that mice with defective embryonic eyelid closure develop less extraocular muscle than normal mice. In addition, the size of the eyeballs was noticeably reduced in mice with defective embryonic eyelid closure. Conclusions We demonstrated that MRI can potentially be used for the study of extraocular muscle in the mouse model of the eye open-at-birth defect, despite the lack of specificity of muscle group provided by the current imaging resolution. PMID:28848319

  9. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collectmore » and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.« less

  10. A human visual model-based approach of the visual attention and performance evaluation

    NASA Astrophysics Data System (ADS)

    Le Meur, Olivier; Barba, Dominique; Le Callet, Patrick; Thoreau, Dominique

    2005-03-01

    In this paper, a coherent computational model of visual selective attention for color pictures is described and its performances are precisely evaluated. The model based on some important behaviours of the human visual system is composed of four parts: visibility, perception, perceptual grouping and saliency map construction. This paper focuses mainly on its performances assessment by achieving extended subjective and objective comparisons with real fixation points captured by an eye-tracking system used by the observers in a task-free viewing mode. From the knowledge of the ground truth, qualitatively and quantitatively comparisons have been made in terms of the measurement of the linear correlation coefficient (CC) and of the Kulback Liebler divergence (KL). On a set of 10 natural color images, the results show that the linear correlation coefficient and the Kullback Leibler divergence are of about 0.71 and 0.46, respectively. CC and Kl measures with this model are respectively improved by about 4% and 7% compared to the best model proposed by L.Itti. Moreover, by comparing the ability of our model to predict eye movements produced by an average observer, we can conclude that our model succeeds quite well in predicting the spatial locations of the most important areas of the image content.

  11. Objective evaluation of the visual acuity in human eyes

    NASA Astrophysics Data System (ADS)

    Rosales, M. A.; López-Olazagasti, E.; Ramírez-Zavaleta, G.; Varillas, G.; Tepichín, E.

    2009-08-01

    Traditionally, the quality of the human vision is evaluated by a subjective test in which the examiner asks the patient to read a series of characters of different sizes, located at a certain distance of the patient. Typically, we need to ensure a subtended angle of vision of 5 minutes, which implies an object of 8.8 mm high located at 6 meters (normal or 20/20 visual acuity). These characters constitute what is known as the Snellen chart, universally used to evaluate the spatial resolution of the human eyes. The mentioned process of identification of characters is carried out by means of the eye - brain system, giving an evaluation of the subjective visual performance. In this work we consider the eye as an isolated image-forming system, and show that it is possible to isolate the function of the eye from that of the brain in this process. By knowing the impulse response of the eye´s system we can obtain, in advance, the image of the Snellen chart simultaneously. From this information, we obtain the objective performance of the eye as the optical system under test. This type of results might help to detect anomalous situations of the human vision, like the so called "cerebral myopia".

  12. Numerical analysis of specific absorption rate in the human head due to a 13.56 MHz RFID-based intra-ocular pressure measurement system.

    PubMed

    Hirtl, Rene; Schmid, Gernot

    2013-09-21

    A modern wireless intra-ocular pressure monitoring system, based on 13.56 MHz inductively coupled data transmission, was dosimetrically analyzed with respect to the specific absorption rate (SAR) induced inside the head and the eye due to the electromagnetic field exposure caused by the reader antenna of the transmission system. The analysis was based on numerical finite difference time domain computations using a high resolution anatomical eye model integrated in a modern commercially available anatomical model of a male head. Three different reader antenna configurations, a 7-turn elliptic (30 mm × 50 mm) antenna at 12 mm distance from the eye, a flexible circular antenna (60 mm diameter, 8 turns on 2 mm substrate) directly attached to the skin, and a circular 7-turn antenna (30 mm diameter at 12 mm distance to the eye) were analyzed, respectively. Possible influences of the eye-lid status (closed or opened) and the transponder antenna contained in a contact lens directly attached to the eye were taken into account. The results clearly demonstrated that for typical reader antenna currents required for proper data transmission, the SAR values remain far below the limits for localized exposure of the head, as defined by the International Commission for Non-Ionizing Radiation Protection. Particularly the induced SAR inside the eye was found to be substantially (orders of magnitudes for typical reader antenna currents in the order of 1 A turn) below values which have been reported to be critical with respect to thermally induced adverse health effects in eye tissues.

  13. Extended Fitts' model of pointing time in eye-gaze input system - Incorporating effects of target shape and movement direction into modeling.

    PubMed

    Murata, Atsuo; Fukunaga, Daichi

    2018-04-01

    This study attempted to investigate the effects of the target shape and the movement direction on the pointing time using an eye-gaze input system and extend Fitts' model so that these factors are incorporated into the model and the predictive power of Fitts' model is enhanced. The target shape, the target size, the movement distance, and the direction of target presentation were set as within-subject experimental variables. The target shape included: a circle, and rectangles with an aspect ratio of 1:1, 1:2, 1:3, and 1:4. The movement direction included eight directions: upper, lower, left, right, upper left, upper right, lower left, and lower right. On the basis of the data for identifying the effects of the target shape and the movement direction on the pointing time, an attempt was made to develop a generalized and extended Fitts' model that took into account the movement direction and the target shape. As a result, the generalized and extended model was found to fit better to the experimental data, and be more effective for predicting the pointing time for a variety of human-computer interaction (HCI) task using an eye-gaze input system. Copyright © 2017. Published by Elsevier Ltd.

  14. The Science of Colour

    ERIC Educational Resources Information Center

    Edwards, S. J.

    1975-01-01

    Provides information on how humans see color including sensitivity of the eye, spatial effects, and temporal effects, and relative to the characteristics of the human eye explains how color is measured. (GS)

  15. Face Processing: Models For Recognition

    NASA Astrophysics Data System (ADS)

    Turk, Matthew A.; Pentland, Alexander P.

    1990-03-01

    The human ability to process faces is remarkable. We can identify perhaps thousands of faces learned throughout our lifetime and read facial expression to understand such subtle qualities as emotion. These skills are quite robust, despite sometimes large changes in the visual stimulus due to expression, aging, and distractions such as glasses or changes in hairstyle or facial hair. Computers which model and recognize faces will be useful in a variety of applications, including criminal identification, human-computer interface, and animation. We discuss models for representing faces and their applicability to the task of recognition, and present techniques for identifying faces and detecting eye blinks.

  16. Research on the liquid crystal adaptive optics system for human retinal imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Tong, Shoufeng; Song, Yansong; Zhao, Xin

    2013-12-01

    The blood vessels only in Human eye retinal can be observed directly. Many diseases that are not obvious in their early symptom can be diagnosed through observing the changes of distal micro blood vessel. In order to obtain the high resolution human retinal images,an adaptive optical system for correcting the aberration of the human eye was designed by using the Shack-Hartmann wavefront sensor and the Liquid Crystal Spatial Light Modulator(LCLSM) .For a subject eye with 8m-1 (8D)myopia, the wavefront error is reduced to 0.084 λ PV and 0.12 λRMS after adaptive optics(AO) correction ,which has reached diffraction limit.The results show that the LCLSM based AO system has the ability of correcting the aberration of the human eye efficiently,and making the blurred photoreceptor cell to clearly image on a CCD camera.

  17. Personal identification by eyes.

    PubMed

    Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana

    2011-09-01

    Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.

  18. Further evidence for population specific differences in the effect of DNA markers and gender on eye colour prediction in forensics.

    PubMed

    Pośpiech, Ewelina; Karłowska-Pik, Joanna; Ziemkiewicz, Bartosz; Kukla, Magdalena; Skowron, Małgorzata; Wojas-Pelc, Anna; Branicki, Wojciech

    2016-07-01

    The genetics of eye colour has been extensively studied over the past few years, and the identified polymorphisms have been applied with marked success in the field of Forensic DNA Phenotyping. A picture that arises from evaluation of the currently available eye colour prediction markers shows that only the analysis of HERC2-OCA2 complex has similar effectiveness in different populations, while the predictive potential of other loci may vary significantly. Moreover, the role of gender in the explanation of human eye colour variation should not be neglected in some populations. In the present study, we re-investigated the data for 1020 Polish individuals and using neural networks and logistic regression methods explored predictive capacity of IrisPlex SNPs and gender in this population sample. In general, neural networks provided higher prediction accuracy comparing to logistic regression (AUC increase by 0.02-0.06). Four out of six IrisPlex SNPs were associated with eye colour in the studied population. HERC2 rs12913832, OCA2 rs1800407 and SLC24A4 rs12896399 were found to be the most important eye colour predictors (p < 0.007) while the effect of rs16891982 in SLC45A2 was less significant. Gender was found to be significantly associated with eye colour with males having ~1.5 higher odds for blue eye colour comparing to females (p = 0.002) and was ranked as the third most important factor in blue/non-blue eye colour determination. However, the implementation of gender into the developed prediction models had marginal and ambiguous impact on the overall accuracy of prediction confirming that the effect of gender on eye colour in this population is small. Our study indicated the advantage of neural networks in prediction modeling in forensics and provided additional evidence for population specific differences in the predictive importance of the IrisPlex SNPs and gender.

  19. Non-invasive quantification of hemodynamics in human choriocapillaries

    NASA Astrophysics Data System (ADS)

    Yu, Huidan (Whitney); Chen, Rou; An, Senyou; McDonough, James; Gelfand, Bradley; Yao, Jun

    2016-11-01

    The development of retinal disease is inextricably linked to defects in the choroidal blood supply. However, to date a description of the hemodynamics in the human choroidal circulation is lacking. Through high resolution choroidal vascular network mapped from immunofluorescent labeling and confocal microscopy of human cadaver donor eyes. We noninvasively quantify hemodynamics including velocity, pressure, and wall-shear stress (WSS) in choriocapillaries through mesoscale modeling and GPU-accelerated fast computation. This is the first-ever map of hemodynamic parameters (WSS, pressure, and velocity) in anatomically accurate human choroidal vasculature in health and disease. The pore scale simulation results are used to evaluate porous media models with the same porosity and boundary conditions. School of Medicine, Indiana University.

  20. Experimental tests of a superposition hypothesis to explain the relationship between the vestibuloocular reflex and smooth pursuit during horizontal combined eye-head tracking in humans

    NASA Technical Reports Server (NTRS)

    Huebner, W. P.; Leigh, R. J.; Seidman, S. H.; Thomas, C. W.; Billian, C.; DiScenna, A. O.; Dell'Osso, L. F.

    1992-01-01

    1. We used a modeling approach to test the hypothesis that, in humans, the smooth pursuit (SP) system provides the primary signal for cancelling the vestibuloocular reflex (VOR) during combined eye-head tracking (CEHT) of a target moving smoothly in the horizontal plane. Separate models for SP and the VOR were developed. The optimal values of parameters of the two models were calculated using measured responses of four subjects to trials of SP and the visually enhanced VOR. After optimal parameter values were specified, each model generated waveforms that accurately reflected the subjects' responses to SP and vestibular stimuli. The models were then combined into a CEHT model wherein the final eye movement command signal was generated as the linear summation of the signals from the SP and VOR pathways. 2. The SP-VOR superposition hypothesis was tested using two types of CEHT stimuli, both of which involved passive rotation of subjects in a vestibular chair. The first stimulus consisted of a "chair brake" or sudden stop of the subject's head during CEHT; the visual target continued to move. The second stimulus consisted of a sudden change from the visually enhanced VOR to CEHT ("delayed target onset" paradigm); as the vestibular chair rotated past the angular position of the stationary visual stimulus, the latter started to move in synchrony with the chair. Data collected during experiments that employed these stimuli were compared quantitatively with predictions made by the CEHT model. 3. During CEHT, when the chair was suddenly and unexpectedly stopped, the eye promptly began to move in the orbit to track the moving target. Initially, gaze velocity did not completely match target velocity, however; this finally occurred approximately 100 ms after the brake onset. The model did predict the prompt onset of eye-in-orbit motion after the brake, but it did not predict that gaze velocity would initially be only approximately 70% of target velocity. One possible explanation for this discrepancy is that VOR gain can be dynamically modulated and, during sustained CEHT, it may assume a lower value. Consequently, during CEHT, a smaller-amplitude SP signal would be needed to cancel the lower-gain VOR. This reduction of the SP signal could account for the attenuated tracking response observed immediately after the brake. We found evidence for the dynamic modulation of VOR gain by noting differences in responses to the onset and offset of head rotation in trials of the visually enhanced VOR.(ABSTRACT TRUNCATED AT 400 WORDS).

  1. Monopolar radiofrequency treatment of the eyelids: a safety evaluation.

    PubMed

    Biesman, Brian S; Pope, Karl

    2007-07-01

    Monopolar radiofrequency (RF) energy has been used to successfully accomplish noninvasive skin tightening of the face, abdomen, and extremities. Owing to concerns about injury to the eye itself, monopolar RF treatment of the eyelids has not been feasible. The objective was to evaluate the safety of a novel 0.25-cm(2)"shallow" treatment tip for noninvasive tightening of eyelid skin. This was a tripartite study that began with an animal model to evaluate soft tissue effects and temperature change at the ocular surface. Findings were then extrapolated to ex vivo evaluation of human eyelids and ultimately to an in vivo human eyelid safety study. The animal studies demonstrated that the 0.25-cm(2) treatment tip could be used safely on eyelids in conjunction with appropriate ocular protection. The ex vivo human eyelid studies confirmed that, at typical treatment settings, the shallow treatment tip did not produce frank eyelid injury. The in vivo human studies confirmed that, at the tested settings, the novel treatment tip did not injure the eyelids or eyes. If used properly, the 0.25-cm(2) treatment tip can be safely used on human eyelids.

  2. Monitoring and decision making by people in man machine systems

    NASA Technical Reports Server (NTRS)

    Johannsen, G.

    1979-01-01

    The analysis of human monitoring and decision making behavior as well as its modeling are described. Classic and optimal control theoretical, monitoring models are surveyed. The relationship between attention allocation and eye movements is discussed. As an example of applications, the evaluation of predictor displays by means of the optimal control model is explained. Fault detection involving continuous signals and decision making behavior of a human operator engaged in fault diagnosis during different operation and maintenance situations are illustrated. Computer aided decision making is considered as a queueing problem. It is shown to what extent computer aids can be based on the state of human activity as measured by psychophysiological quantities. Finally, management information systems for different application areas are mentioned. The possibilities of mathematical modeling of human behavior in complex man machine systems are also critically assessed.

  3. Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens.

    PubMed

    Izak, Andrea M; Werner, Liliana; Pandey, Suresh K; Apple, David J

    2004-07-01

    To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.

  4. Molecular Diagnosis of Human Taenia martis Eye Infection.

    PubMed

    Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis

    2016-05-04

    Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. © The American Society of Tropical Medicine and Hygiene.

  5. Questions Students Ask: The Red-Eye Effect.

    ERIC Educational Resources Information Center

    Physics Teacher, 1985

    1985-01-01

    Addresses the question of why a dog's eyes appear red and glow when a flash photograph is taken. Conditions for the red-eye effect, light paths involved, structure of the eye, and typical cameras and lenses are discussed. Also notes differences between the eyes of nocturnal animals and humans. (JN)

  6. Application of a new high-speed magnetic deformable mirror for in-vivo retinal imaging

    NASA Astrophysics Data System (ADS)

    Balderas-Mata, Sandra E.; Jones, Steven M.; Zawadzki, Robert J.; Werner, John S.

    2011-08-01

    Nowadays in ophthalmologic practice several commercial instruments are available to image patient retinas in vivo. Many modern fundus cameras and confocal scanning laser ophthalmoscopes allow acquisition of two dimensional en face images of the retina with both back reflected as well as fluorescent light. Additionally, optical coherence tomography systems allow non-invasive probing of three-dimensional retinal morphology. For all of these instruments the available lateral resolution is limited by optical quality of the human eye used as the imaging objective. To improve lateral resolution and achieve diffraction-limited imaging, adaptive optics (AO) can be implemented with any of these imaging systems to correct both static and dynamic aberrations inherent in human eyes. Most of the wavefront correctors used previously in AO systems have limited dynamic range and an insufficient number of actuators to achieve diffraction-limited correction of most human eyes. Thus, additional corrections were necessary, either by trial lenses or additional deformable mirrors (DMs). The UC Davis AO flood-illuminated fundus camera system described in this paper has been previously used to acquire in vivo images of the photoreceptor mosaic and for psychophysical studies on normal and diseased retinas. These results were acquired using a DM manufactured by Litton ITEK (DM109), which has 109 actuators arranged in a hexagonal array below a continuous front-surface mirror. It has an approximate surface actuator stroke of +/-2μm. Here we present results with a new hi-speed magnetic DM manufactured by ALPAO (DM97, voice coil technology), which has 97 actuators and similar inter-actuator stroke (>3μm, mirror surface) but much higher low-order aberration correction (defocus stroke of at least +/-30μm) than the previous one. In this paper we report results of testing performance of the ALPAO DM for the correction of human eye aberrations. Additionally changes made to our AO flood illuminated system are presented along with images of the model eye retina and in-vivo human retina acquired with this system.

  7. Effects of a human VEGF antibody (Bevacizumab) on deprivation myopia and choroidal thickness in the chicken.

    PubMed

    Mathis, Ute; Ziemssen, Focke; Schaeffel, Frank

    2014-10-01

    Vascular endothelial growth factor (VEGF) is a dimeric glycoprotein which is responsible for neovascularization and fenestrations of the choriocapillaris. In neovascular maculopathies secondary to age-related degeneration (nAMD) or pathologic myopia (PM-CNV), its inhibition by humanized antibodies is currently the most successful therapy. The choroid has an important role in maintaining retinal health and its thickness declines with age and with myopia. Since choroidal thickness depends on its perfusion rate, one would expect that anti-VEGF agents can also change choroidal thickness. We have tested the hypothesis in the chicken model, using a humanized antibody, Bevacizumab, and also studied the distribution of VEGF-A in the chicken fundal layers by immunohistochemical techniques. Even though it was raised against human VEGF, Bevacizumab had several long lasting effects in the chicken eye (1) after a single unilateral intravitreal injection of 0.5 mg, it partially suppressed the development of deprivation myopia, similarly in both eyes, (2) it completely suppressed choroidal thickening that normally occurs when eyes recover from induced myopia over a time period of about 10 days, (3) it had little effect on the choroidal thickness in eyes that had normal visual experience, (4) VEGF-A was absent in sclera, but highly expressed in the walls of choroidal blood vessels and presumed nerve fiber bundles, as well as in retinal photoreceptors and cells of the inner and outer nuclear layer. One day after the injection of Bevacizumab, the immunoreactivity against VEGF-A had largely disappeared. In conclusion, Bevacizumab is similary effective in human and chicken tissue, has similar time constants (few days), has almost symmetrical effects on myopia in both eyes even after monocular application, and fully suppresses choroidal thickening that normally occurs during recovery from deprivation myopia. The mechanisms by which Bevacizumab acts on the choroidal thickness are perhaps most interesting, both to better understand the role of the choroid in myopia development but also to clarify its potential side effects during nAMD and PM-CNV treatment in the clinics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Are readers of our face readers of our minds? Dogs (Canis familiaris) show situation-dependent recognition of human's attention.

    PubMed

    Gácsi, Márta; Miklósi, Adám; Varga, Orsolya; Topál, József; Csányi, Vilmos

    2004-07-01

    The ability of animals to use behavioral/facial cues in detection of human attention has been widely investigated. In this test series we studied the ability of dogs to recognize human attention in different experimental situations (ball-fetching game, fetching objects on command, begging from humans). The attentional state of the humans was varied along two variables: (1) facing versus not facing the dog; (2) visible versus non-visible eyes. In the first set of experiments (fetching) the owners were told to take up different body positions (facing or not facing the dog) and to either cover or not cover their eyes with a blindfold. In the second set of experiments (begging) dogs had to choose between two eating humans based on either the visibility of the eyes or direction of the face. Our results show that the efficiency of dogs to discriminate between "attentive" and "inattentive" humans depended on the context of the test, but they could rely on the orientation of the body, the orientation of the head and the visibility of the eyes. With the exception of the fetching-game situation, they brought the object to the front of the human (even if he/she turned his/her back towards the dog), and preferentially begged from the facing (or seeing) human. There were also indications that dogs were sensitive to the visibility of the eyes because they showed increased hesitative behavior when approaching a blindfolded owner, and they also preferred to beg from the person with visible eyes. We conclude that dogs are able to rely on the same set of human facial cues for detection of attention, which form the behavioral basis of understanding attention in humans. Showing the ability of recognizing human attention across different situations dogs proved to be more flexible than chimpanzees investigated in similar circumstances.

  9. 76 FR 33286 - Privacy Act of 1974; System of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-08

    ... locations: Federal Housing Finance Agency, Office of Human Resources Management, 1700 G Street, NW... Human Resources Management, 1700 G Street, NW., Washington, DC 20552; 1625 Eye Street, NW., Washington...: Office of Human Resources Management, Federal Housing Finance Agency, 1625 Eye Street, NW., Washington...

  10. Simulation and analysis of light scattering by multilamellar bodies present in the human eye

    PubMed Central

    Méndez-Aguilar, Emilia M.; Kelly-Pérez, Ismael; Berriel-Valdos, L. R.; Delgado-Atencio, José A.

    2017-01-01

    A modified computational model of the human eye was used to obtain and compare different probability density functions, radial profiles of light pattern distributions, and images of the point spread function formed in the human retina under the presence of different kinds of particles inside crystalline lenses suffering from cataracts. Specifically, this work uses simple particles without shells and multilamellar bodies (MLBs) with shells. The emergence of such particles alters the formation of images on the retina. Moreover, the MLBs change over time, which affects properties such as the refractive index of their shell. Hence, this work not only simulates the presence of such particles but also evaluates the incidence of particle parameters such as particle diameter, particle thickness, and shell refractive index, which are set based on reported experimental values. In addition, two wavelengths (400 nm and 700 nm) are used for light passing through the different layers of the computational model. The effects of these parameters on light scattering are analyzed using the simulation results. Further, in these results, the effects of light scattering on image formation can be seen when single particles, early-stage MLBs, or mature MLBs are incorporated in the model. Finally, it is found that particle diameter has the greatest impact on image formation. PMID:28663924

  11. Simulation and analysis of light scattering by multilamellar bodies present in the human eye.

    PubMed

    Méndez-Aguilar, Emilia M; Kelly-Pérez, Ismael; Berriel-Valdos, L R; Delgado-Atencio, José A

    2017-06-01

    A modified computational model of the human eye was used to obtain and compare different probability density functions, radial profiles of light pattern distributions, and images of the point spread function formed in the human retina under the presence of different kinds of particles inside crystalline lenses suffering from cataracts. Specifically, this work uses simple particles without shells and multilamellar bodies (MLBs) with shells. The emergence of such particles alters the formation of images on the retina. Moreover, the MLBs change over time, which affects properties such as the refractive index of their shell. Hence, this work not only simulates the presence of such particles but also evaluates the incidence of particle parameters such as particle diameter, particle thickness, and shell refractive index, which are set based on reported experimental values. In addition, two wavelengths (400 nm and 700 nm) are used for light passing through the different layers of the computational model. The effects of these parameters on light scattering are analyzed using the simulation results. Further, in these results, the effects of light scattering on image formation can be seen when single particles, early-stage MLBs, or mature MLBs are incorporated in the model. Finally, it is found that particle diameter has the greatest impact on image formation.

  12. Simulating Visual Attention Allocation of Pilots in an Advanced Cockpit Environment

    NASA Technical Reports Server (NTRS)

    Frische, F.; Osterloh, J.-P.; Luedtke, A.

    2011-01-01

    This paper describes the results of experiments conducted with human line pilots and a cognitive pilot model during interaction with a new 40 Flight Management System (FMS). The aim of these experiments was to gather human pilot behavior data in order to calibrate the behavior of the model. Human behavior is mainly triggered by visual perception. Thus, the main aspect was to setup a profile of human pilots' visual attention allocation in a cockpit environment containing the new FMS. We first performed statistical analyses of eye tracker data and then compared our results to common results of familiar analyses in standard cockpit environments. The comparison has shown a significant influence of the new system on the visual performance of human pilots. Further on, analyses of the pilot models' visual performance have been performed. A comparison to human pilots' visual performance revealed important improvement potentials.

  13. Irreversible Electroporation of Human Primary Uveal Melanoma in Enucleated Eyes

    PubMed Central

    Mandel, Yossi; Laufer, Shlomi; Belkin, Michael; Rubinsky, Boris; Pe'er, Jacob; Frenkel, Shahar

    2013-01-01

    Uveal melanoma (UM) is the most common primary intraocular tumor in adults and is characterized by high rates of metastatic disease. Although brachytherapy is the most common globe-sparing treatment option for small- and medium-sized tumors, the treatment is associated with severe adverse reactions and does not lead to increased survival rates as compared to enucleation. The use of irreversible electroporation (IRE) for tumor ablation has potential advantages in the treatment of tumors in complex organs such as the eye. Following previous theoretical work, herein we evaluate the use of IRE for uveal tumor ablation in human ex vivo eye model. Enucleated eyes of patients with uveal melanoma were treated with short electric pulses (50–100 µs, 1000–2000 V/cm) using a customized electrode design. Tumor bioimpedance was measured before and after treatment and was followed by histopathological evaluation. We found that IRE caused tumor ablation characterized by cell membrane disruption while sparing the non-cellular sclera. Membrane disruption and loss of cellular capacitance were also associated with significant reduction in total tumor impedance and loss of impedance frequency dependence. The effect was more pronounced near the pulsing electrodes and was dependent on time from treatment to fixation. Future studies should further evaluate the potential of IRE as an alternative method of uveal melanoma treatment. PMID:24039721

  14. Initial eye movements during face identification are optimal and similar across cultures

    PubMed Central

    Or, Charles C.-F.; Peterson, Matthew F.; Eckstein, Miguel P.

    2015-01-01

    Culture influences not only human high-level cognitive processes but also low-level perceptual operations. Some perceptual operations, such as initial eye movements to faces, are critical for extraction of information supporting evolutionarily important tasks such as face identification. The extent of cultural effects on these crucial perceptual processes is unknown. Here, we report that the first gaze location for face identification was similar across East Asian and Western Caucasian cultural groups: Both fixated a featureless point between the eyes and the nose, with smaller between-group than within-group differences and with a small horizontal difference across cultures (8% of the interocular distance). We also show that individuals of both cultural groups initially fixated at a slightly higher point on Asian faces than on Caucasian faces. The initial fixations were found to be both fundamental in acquiring the majority of information for face identification and optimal, as accuracy deteriorated when observers held their gaze away from their preferred fixations. An ideal observer that integrated facial information with the human visual system's varying spatial resolution across the visual field showed a similar information distribution across faces of both races and predicted initial human fixations. The model consistently replicated the small vertical difference between human fixations to Asian and Caucasian faces but did not predict the small horizontal leftward bias of Caucasian observers. Together, the results suggest that initial eye movements during face identification may be driven by brain mechanisms aimed at maximizing accuracy, and less influenced by culture. The findings increase our understanding of the interplay between the brain's aims to optimally accomplish basic perceptual functions and to respond to sociocultural influences. PMID:26382003

  15. Holocamera for 3-D micrography of the alert human eye

    NASA Astrophysics Data System (ADS)

    Tokuda, A. R.; Auth, D. C.; Bruckner, A. P.

    1980-07-01

    A holocamera that safely records holograms of the full depth of the alert human eye with a spatial resolution of about 20 microns is described. A single-mode argon-ion laser generating 2 W at 5145 A serves as the illuminating source. Holographic exposure times of 0.3 msec are achieved by means of a fail-safe electromechanical shutter system. Integrated retinal irradiance levels are well under the American National Standards Institute safety standards. Reconstructed real images are projected directly onto the vidicon faceplate of a closed-circuit TV system, enabling convenient scanning in the x-y-z dimensions of the reconstructed eyeball. Serially reconstructed holograms of cataractous rabbit eyes and normal human eyes are presented.

  16. Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    PubMed

    Hu, Panpan; Kong, Yan; Chen, Bo; Liu, Qianqian; Zhuo, Weihai; Liu, Haikuan

    2017-04-20

    To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Spdef Null Mice Lack Conjunctival Goblet Cells and Provide a Model of Dry Eye

    PubMed Central

    Marko, Christina K.; Menon, Balaraj B.; Chen, Gang; Whitsett, Jeffrey A.; Clevers, Hans; Gipson, Ilene K.

    2014-01-01

    Goblet cell numbers decrease within the conjunctival epithelium in drying and cicatrizing ocular surface diseases. Factors regulating goblet cell differentiation in conjunctival epithelium are unknown. Recent data indicate that the transcription factor SAM-pointed domain epithelial-specific transcription factor (Spdef) is essential for goblet cell differentiation in tracheobronchial and gastrointestinal epithelium of mice. Using Spdef−/− mice, we determined that Spdef is required for conjunctival goblet cell differentiation and that Spdef−/− mice, which lack conjunctival goblet cells, have significantly increased corneal surface fluorescein staining and tear volume, a phenotype consistent with dry eye. Microarray analysis of conjunctival epithelium in Spdef−/− mice revealed down-regulation of goblet cell–specific genes (Muc5ac, Tff1, Gcnt3). Up-regulated genes included epithelial cell differentiation/keratinization genes (Sprr2h, Tgm1) and proinflammatory genes (Il1-α, Il-1β, Tnf-α), all of which are up-regulated in dry eye. Interestingly, four Wnt pathway genes were down-regulated. SPDEF expression was significantly decreased in the conjunctival epithelium of Sjögren syndrome patients with dry eye and decreased goblet cell mucin expression. These data demonstrate that Spdef is required for conjunctival goblet cell differentiation and down-regulation of SPDEF may play a role in human dry eye with goblet cell loss. Spdef−/− mice have an ocular surface phenotype similar to that in moderate dry eye, providing a new, more convenient model for the disease. PMID:23665202

  18. Spdef null mice lack conjunctival goblet cells and provide a model of dry eye.

    PubMed

    Marko, Christina K; Menon, Balaraj B; Chen, Gang; Whitsett, Jeffrey A; Clevers, Hans; Gipson, Ilene K

    2013-07-01

    Goblet cell numbers decrease within the conjunctival epithelium in drying and cicatrizing ocular surface diseases. Factors regulating goblet cell differentiation in conjunctival epithelium are unknown. Recent data indicate that the transcription factor SAM-pointed domain epithelial-specific transcription factor (Spdef) is essential for goblet cell differentiation in tracheobronchial and gastrointestinal epithelium of mice. Using Spdef(-/-) mice, we determined that Spdef is required for conjunctival goblet cell differentiation and that Spdef(-/-) mice, which lack conjunctival goblet cells, have significantly increased corneal surface fluorescein staining and tear volume, a phenotype consistent with dry eye. Microarray analysis of conjunctival epithelium in Spdef(-/-) mice revealed down-regulation of goblet cell-specific genes (Muc5ac, Tff1, Gcnt3). Up-regulated genes included epithelial cell differentiation/keratinization genes (Sprr2h, Tgm1) and proinflammatory genes (Il1-α, Il-1β, Tnf-α), all of which are up-regulated in dry eye. Interestingly, four Wnt pathway genes were down-regulated. SPDEF expression was significantly decreased in the conjunctival epithelium of Sjögren syndrome patients with dry eye and decreased goblet cell mucin expression. These data demonstrate that Spdef is required for conjunctival goblet cell differentiation and down-regulation of SPDEF may play a role in human dry eye with goblet cell loss. Spdef(-/-) mice have an ocular surface phenotype similar to that in moderate dry eye, providing a new, more convenient model for the disease. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  19. Adaptive Optics for the Human Eye

    NASA Astrophysics Data System (ADS)

    Williams, D. R.

    2000-05-01

    Adaptive optics can extend not only the resolution of ground-based telescopes, but also the human eye. Both static and dynamic aberrations in the cornea and lens of the normal eye limit its optical quality. Though it is possible to correct defocus and astigmatism with spectacle lenses, higher order aberrations remain. These aberrations blur vision and prevent us from seeing at the fundamental limits set by the retina and brain. They also limit the resolution of cameras to image the living retina, cameras that are a critical for the diagnosis and treatment of retinal disease. I will describe an adaptive optics system that measures the wave aberration of the eye in real time and compensates for it with a deformable mirror, endowing the human eye with unprecedented optical quality. This instrument provides fresh insight into the ultimate limits on human visual acuity, reveals for the first time images of the retinal cone mosaic responsible for color vision, and points the way to contact lenses and laser surgical methods that could enhance vision beyond what is currently possible today. Supported by the NSF Science and Technology Center for Adaptive Optics, the National Eye Institute, and Bausch and Lomb, Inc.

  20. Predictive performance of the Vitrigel‐eye irritancy test method using 118 chemicals

    PubMed Central

    Yamaguchi, Hiroyuki; Kojima, Hajime

    2015-01-01

    Abstract We recently developed a novel Vitrigel‐eye irritancy test (EIT) method. The Vitrigel‐EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time‐dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel‐EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel‐EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false‐negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false‐positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO‐1, a tight junction‐associated protein and MUC1, a cell membrane‐spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false‐positive chemicals, suggesting that such false‐positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel‐EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel‐EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:26472347

  1. Personalized pseudophakic model

    NASA Astrophysics Data System (ADS)

    Ribeiro, F.; Castanheira-Dinis, A.; Dias, J. M.

    2014-08-01

    With the aim of taking into account all optical aberrations, a personalized pseudophakic optical model was designed for refractive evaluation using ray tracing software. Starting with a generic model, all clinically measurable data were replaced by personalized measurements. Data from corneal anterior and posterior surfaces were imported from a grid of elevation data obtained by topography, and a formula for the calculation of the intraocular lens (IOL) position was developed based on the lens equator. For the assessment of refractive error, a merit function minimized by the approximation of the Modulation Transfer Function values to diffraction limit values on the frequencies corresponding up to the discrimination limits of the human eye, weighted depending on the human contrast sensitivity function, was built. The model was tested on the refractive evaluation of 50 pseudophakic eyes. The developed model shows good correlation with subjective evaluation of a pseudophakic population, having the added advantage of being independent of corrective factors, allowing it to be immediately adaptable to new technological developments. In conclusion, this personalized model, which uses individual biometric values, allows for a precise refractive assessment and is a valuable tool for an accurate IOL power calculation, including in conditions to which population averages and the commonly used regression correction factors do not apply, thus achieving the goal of being both personalized and universally applicable.

  2. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    PubMed

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.

  3. Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings

    PubMed Central

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627

  4. Old and new results about single-photon sensitivity in human vision

    NASA Astrophysics Data System (ADS)

    Nelson, Philip C.

    2016-04-01

    It is sometimes said that ‘our eyes can see single photons’. This article begins by finding a more precise version of that claim and reviewing evidence gathered for it up to around 1985 in two distinct realms, those of human psychophysics and single-cell physiology. Finding a single framework that accommodates both kinds of result is then a nontrivial challenge, and one that sets severe quantitative constraints on any model of dim-light visual processing. This article presents one such model and compares it to a recent experiment.

  5. The eyes and vision of butterflies.

    PubMed

    Arikawa, Kentaro

    2017-08-15

    Butterflies use colour vision when searching for flowers. Unlike the trichromatic retinas of humans (blue, green and red cones; plus rods) and honeybees (ultraviolet, blue and green photoreceptors), butterfly retinas typically have six or more photoreceptor classes with distinct spectral sensitivities. The eyes of the Japanese yellow swallowtail (Papilio xuthus) contain ultraviolet, violet, blue, green, red and broad-band receptors, with each ommatidium housing nine photoreceptor cells in one of three fixed combinations. The Papilio eye is thus a random patchwork of three types of spectrally heterogeneous ommatidia. To determine whether Papilio use all of their receptors to see colours, we measured their ability to discriminate monochromatic lights of slightly different wavelengths. We found that Papilio can detect differences as small as 1-2 nm in three wavelength regions, rivalling human performance. We then used mathematical modelling to infer which photoreceptors are involved in wavelength discrimination. Our simulation indicated that the Papilio vision is tetrachromatic, employing the ultraviolet, blue, green and red receptors. The random array of three ommatidial types is a common feature in butterflies. To address the question of how the spectrally complex eyes of butterflies evolved, we studied their developmental process. We have found that the development of butterfly eyes shares its molecular logic with that of Drosophila: the three-way stochastic expression pattern of the transcription factor Spineless determines the fate of ommatidia, creating the random array in Papilio. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  6. Traumatic eye injuries as a result of blunt impact: computational issues

    NASA Astrophysics Data System (ADS)

    Clemente, C.; Esposito, L.; Bonora, N.; Limido, J.; Lacome, J. L.; Rossi, T.

    2014-05-01

    The detachment or tearing of the retina in the human eye as a result of a collision is a phenomenon that occurs very often. Reliable numerical simulations of eye impact can be very useful tools to understand the physical mechanisms responsible for traumatic eye injuries accompanying blunt impact. The complexity and variability of the physical and mechanical properties of the biological materials, the lack of agreement on their related experimental data as well as the unsuitability of specific numerical codes and models are only some of the difficulties when dealing with this matter. All these challenging issues must be solved to obtain accurate numerical analyses involving dynamic behavior of biological soft tissues. To this purpose, a numerical and experimental investigation of the dynamic response of the eye during an impact event was performed. Numerical simulations were performed with IMPETUS-AFEA, a new general non-linear finite element (FE) software which offers non uniform rational B-splines (NURBS) FE technology for the simulation of large deformation and fracture in materials. IMPETUS code was selected in order to solve hourglass and locking problems typical of nearly incompressible materials like eye tissues. Computational results were compared with the experimental results on fresh enucleated porcine eyes impacted with airsoft pellets.

  7. Quantification of Focal Outflow Enhancement Using Differential Canalograms

    PubMed Central

    Loewen, Ralitsa T.; Brown, Eric N.; Scott, Gordon; Parikh, Hardik; Schuman, Joel S.; Loewen, Nils A.

    2016-01-01

    Purpose To quantify regional changes of conventional outflow caused by ab interno trabeculectomy (AIT). Methods Gonioscopic, plasma-mediated AIT was established in enucleated pig eyes. We developed a program to automatically quantify outflow changes (R, package eye-canalogram, github.com) using a fluorescent tracer reperfusion technique. Trabecular meshwork (TM) ablation was demonstrated with fluorescent spheres in six eyes before formal outflow quantification with two-dye reperfusion canalograms in six additional eyes. Eyes were perfused with a central, intracameral needle at 15 mm Hg. Canalograms and histology were correlated for each eye. Results The pig eye provided a model with high similarity to AIT in human patients. Histology indicated ablation of TM and unroofing of most Schlemm's canal segments. Spheres highlighted additional circumferential and radial outflow beyond the immediate area of ablation. Differential canalograms showed that AIT caused an increase of outflow of 17 ± 5-fold inferonasally, 14 ± 3-fold superonasally, and also an increase in the opposite quadrants with a 2 ± 1-fold increase superotemporally, and 3 ± 3 inferotemporally. Perilimbal specific flow image analysis showed an accelerated nasal filling with an additional perilimbal flow direction into adjacent quadrants. Conclusions A quantitative, differential canalography technique was developed that allows us to quantify supraphysiological outflow enhancement by AIT. PMID:27227352

  8. A psychotechnological review on eye-tracking systems: towards user experience.

    PubMed

    Mele, Maria Laura; Federici, Stefano

    2012-07-01

    The aim of the present work is to show a critical review of the international literature on eye-tracking technologies by focusing on those features that characterize them as 'psychotechnologies'. A critical literature review was conducted through the main psychology, engineering, and computer sciences databases by following specific inclusion and exclusion criteria. A total of 46 matches from 1998 to 2010 were selected for content analysis. Results have been divided into four broad thematic areas. We found that, although there is a growing attention to end-users, most of the studies reviewed in this work are far from being considered as adopting holistic human-computer interaction models that include both individual differences and needs of users. User is often considered only as a measurement object of the functioning of the technological system and not as a real alter-ego of the intrasystemic interaction. In order to fully benefit from the communicative functions of gaze, the research on eye-tracking must emphasize user experience. Eye-tracking systems would become an effective assistive technology for integration, adaptation and neutralization of the environmental barrier only when a holistic model can be applied for both design processes and assessment of the functional components of the interaction.

  9. An oculomotor continuum from exploration to fixation

    PubMed Central

    Otero-Millan, Jorge; Macknik, Stephen L.; Langston, Rachel E.; Martinez-Conde, Susana

    2013-01-01

    During visual exploration, saccadic eye movements scan the scene for objects of interest. During attempted fixation, the eyes are relatively still but often produce microsaccades. Saccadic rates during exploration are higher than those of microsaccades during fixation, reinforcing the classic view that exploration and fixation are two distinct oculomotor behaviors. An alternative model is that fixation and exploration are not dichotomous, but are instead two extremes of a functional continuum. Here, we measured the eye movements of human observers as they either fixed their gaze on a small spot or scanned natural scenes of varying sizes. As scene size diminished, so did saccade rates, until they were continuous with microsaccadic rates during fixation. Other saccadic properties varied as function of image size as well, forming a continuum with microsaccadic parameters during fixation. This saccadic continuum extended to nonrestrictive, ecological viewing conditions that allowed all types of saccades and fixation positions. Eye movement simulations moreover showed that a single model of oculomotor behavior can explain the saccadic continuum from exploration to fixation, for images of all sizes. These findings challenge the view that exploration and fixation are dichotomous, suggesting instead that visual fixation is functionally equivalent to visual exploration on a spatially focused scale. PMID:23533278

  10. Simulation of Thin Film Equations on an Eye-Shaped Domain with Moving Boundary

    NASA Astrophysics Data System (ADS)

    Brosch, Joseph; Driscoll, Tobin; Braun, Richard

    During a normal eye blink, the upper lid moves, and during the upstroke the lid paints a thin tear film over the exposed corneal and conjunctival surfaces. This thin tear film may be modeled by a nonlinear fourth-order PDE derived from lubrication theory. A major stumbling block in the numerical simulation of this model is to include both the geometry of the eye and the movement of the eyelid. Using a pair of orthogonal and conformal maps, we transform a computational box into a rough representation of a human eye where we proceed to simulate the thin tear film equations. Although we give up some realism, we gain spectrally accurate numerical methods on the computational box. We have applied this method to the heat equation on the blinking domain with both Dirichlet and no-flux boundary conditions, in each case demonstrating at least 10 digits of accuracy.. We are able to perform these simulations very quickly (generally in under a minute) using a desktop version of MATLAB. This project was supported by Grant 1022706 (R.J.B., T.A.D., J.K.B.) from the NSF.

  11. Model of transient drug diffusion across cornea.

    PubMed

    Zhang, Wensheng; Prausnitz, Mark R; Edwards, Aurélie

    2004-09-30

    A mathematical model of solute transient diffusion across the cornea to the anterior chamber of the eye was developed for topical drug delivery. Solute bioavailability was predicted given solute molecular radius and octanol-to-water distribution coefficient (Phi), ocular membrane ultrastructural parameters, tear fluid hydrodynamics, as well as solute distribution volume (Vd) and clearance rate (Cla) in the anterior chamber. The results suggest that drug bioavailability is primarily determined by solute lipophilicity. In human eyes, bioavailability is predicted to range between 1% and 5% for lipophilic molecules (Phi>1), and to be less than 0.5% for hydrophilic molecules (Phi<0.01). The simulations indicate that the distribution coefficient that maximizes bioavailability is on the order of 10. It was also found that the maximum solute concentration in the anterior chamber (Cmax) and the time needed to reach Cmax significantly depend on Phi, Vd, and Cla. Consistent with experimental findings, model predictions suggest that drug bioavailability can be increased by lowering the conjunctival-to-corneal permeability ratio and reducing precorneal solute drainage. Because of its mechanistic basis, this model will be useful to predict drug transport kinetics and bioavailability for new compounds and in diseased eyes.

  12. The effects of two different types of bandage contact lenses on the healthy canine eye.

    PubMed

    Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse

    2018-02-06

    To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.

  13. Monocular zones in stereoscopic scenes: A useful source of information for human binocular vision?

    NASA Astrophysics Data System (ADS)

    Harris, Julie M.

    2010-02-01

    When an object is closer to an observer than the background, the small differences between right and left eye views are interpreted by the human brain as depth. This basic ability of the human visual system, called stereopsis, lies at the core of all binocular three-dimensional (3-D) perception and related technological display development. To achieve stereopsis, it is traditionally assumed that corresponding locations in the right and left eye's views must first be matched, then the relative differences between right and left eye locations are used to calculate depth. But this is not the whole story. At every object-background boundary, there are regions of the background that only one eye can see because, in the other eye's view, the foreground object occludes that region of background. Such monocular zones do not have a corresponding match in the other eye's view and can thus cause problems for depth extraction algorithms. In this paper I will discuss evidence, from our knowledge of human visual perception, illustrating that monocular zones do not pose problems for our human visual systems, rather, our visual systems can extract depth from such zones. I review the relevant human perception literature in this area, and show some recent data aimed at quantifying the perception of depth from monocular zones. The paper finishes with a discussion of the potential importance of considering monocular zones, for stereo display technology and depth compression algorithms.

  14. 76 FR 10041 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Clinical... agreement applications. Place: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852. (Telephone...

  15. 76 FR 2914 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... National Eye Institute, including consideration of personnel qualifications and performances, and the... invasion of personal privacy. Name of Committee: Board of Scientific Counselors, National Eye Institute...

  16. 75 FR 52762 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Institutional... Officer, Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635...

  17. 77 FR 71428 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical..., Scientific Review Officer, Division of Extramural Research, National Eye Institute, National Institutes of...

  18. PSF and MTF comparison of two different surface ablation techniques for laser visual correction

    NASA Astrophysics Data System (ADS)

    Cruz Félix, Angel Sinue; López Olazagasti, Estela; Rosales, Marco A.; Ibarra, Jorge; Tepichín Rodríguez, Eduardo

    2009-08-01

    It is well known that the Zernike expansion of the wavefront aberrations has been extensively used to evaluate the performance of image forming optical systems. Recently, these techniques were adopted in the field of Ophthalmology to evaluate the objective performance of the human ocular system. We have been working in the characterization and evaluation of the performance of normal human eyes; i.e., eyes which do not require any refractive correction (20/20 visual acuity). These data provide us a reference model to analyze Pre- and Post-Operated results from eyes that have been subjected to laser refractive surgery. Two different ablation techniques are analyzed in this work. These techniques were designed to correct the typical refractive errors known as myopia, hyperopia, and presbyopia. When applied to the corneal surface, these techniques provide a focal shift and, in principle, an improvement of the visual performance. These features can be suitably described in terms of the PSF and MTF of the corresponding Pre- and Post-Operated wavefront aberrations. We show the preliminary results of our comparison.

  19. The effect of transcranial direct current stimulation on contrast sensitivity and visual evoked potential amplitude in adults with amblyopia

    PubMed Central

    Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P.; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2016-01-01

    Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia. PMID:26763954

  20. The effect of transcranial direct current stimulation on contrast sensitivity and visual evoked potential amplitude in adults with amblyopia.

    PubMed

    Ding, Zhaofeng; Li, Jinrong; Spiegel, Daniel P; Chen, Zidong; Chan, Lily; Luo, Guangwei; Yuan, Junpeng; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2016-01-14

    Amblyopia is a neurodevelopmental disorder of vision that occurs when the visual cortex receives decorrelated inputs from the two eyes during an early critical period of development. Amblyopic eyes are subject to suppression from the fellow eye, generate weaker visual evoked potentials (VEPs) than fellow eyes and have multiple visual deficits including impairments in visual acuity and contrast sensitivity. Primate models and human psychophysics indicate that stronger suppression is associated with greater deficits in amblyopic eye contrast sensitivity and visual acuity. We tested whether transcranial direct current stimulation (tDCS) of the visual cortex would modulate VEP amplitude and contrast sensitivity in adults with amblyopia. tDCS can transiently alter cortical excitability and may influence suppressive neural interactions. Twenty-one patients with amblyopia and twenty-seven controls completed separate sessions of anodal (a-), cathodal (c-) and sham (s-) visual cortex tDCS. A-tDCS transiently and significantly increased VEP amplitudes for amblyopic, fellow and control eyes and contrast sensitivity for amblyopic and control eyes. C-tDCS decreased VEP amplitude and contrast sensitivity and s-tDCS had no effect. These results suggest that tDCS can modulate visual cortex responses to information from adult amblyopic eyes and provide a foundation for future clinical studies of tDCS in adults with amblyopia.

  1. The selective disruption of spatial working memory by eye movements

    PubMed Central

    Postle, Bradley R.; Idzikowski, Christopher; Sala, Sergio Della; Logie, Robert H.; Baddeley, Alan D.

    2005-01-01

    In the late 1970s/early 1980s, Baddeley and colleagues conducted a series of experiments investigating the role of eye movements in visual working memory. Although only described briefly in a book (Baddeley, 1986), these studies have influenced a remarkable number of empirical and theoretical developments in fields ranging from experimental psychology to human neuropsychology to nonhuman primate electrophysiology. This paper presents, in full detail, three critical studies from this series, together with a recently performed study that includes a level of eye movement measurement and control that was not available for the older studies. Together, the results demonstrate several facts about the sensitivity of visuospatial working memory to eye movements. First, it is eye movement control, not movement per se, that produces the disruptive effects. Second, these effects are limited to working memory for locations, and do not generalize to visual working memory for shapes. Third, they can be isolated to the storage/maintenance components of working memory (e.g., to the delay period of the delayed-recognition task). These facts have important implications for models of visual working memory. PMID:16556561

  2. Secchi disk observation with spectral-selective glasses in blue and green waters.

    PubMed

    Lee, Zhongping; Shang, Shaoling; Lin, Gong; Liu, Tongtong; Liu, Yangyang; Du, Keping; Luis, Kelly

    2017-08-21

    Radiative transfer modeling of Secchi disk observations has historically been based on conjugated signals of eye response and radiance, where water's attenuation in the entire visible band is included in the attenuation when deciding the Secchi disk depth in water. Aas et al. [Ocean Sci.10(2), 177 (2014)Remote Sens. Environ.169, 139 (2015)] hypothesized that it is actually the attenuation in water's transparent window that matters to the observation of a Secchi disk in water. To test this hypothesis, observations of Secchi disks in blue and green waters were conducted via naked eyes, blue-pass glasses, and green-pass glasses. Measurement results indicate that for blue waters, the observed Secchi depths via naked eyes match the depths obtained with blue-pass glasses and much deeper than the depths with green-pass glasses, although the green-pass glasses match the highest response of human eyes. These observations experimentally support the hypothesis that our eye-brain system uses the contrast information in the transparent window to make a judgement decision regarding sighting a Secchi disk in water.

  3. Retinitis-pigmentosa-like tapetoretinal degeneration in a rabbit breed.

    PubMed

    Reichenbach, A; Baar, U

    1985-08-15

    By chance, we found a rabbit strain with retinal dystrophy. The eyes of these rabbits were examined by ophthalmoscopy, electroretinography, histology, and cytology--the latter after retina dissociation with papaine. The results suggest this rabbit strain to be a possible animal model for human retinitis pigmentosa.

  4. Case Study: Organotypic human in vitro models of embryonic morphogenetic fusion

    EPA Science Inventory

    Morphogenetic fusion of tissues is a common event in embryonic development and disruption of fusion is associated with birth defects of the eye, heart, neural tube, phallus, palate, and other organ systems. Embryonic tissue fusion requires precise regulation of cell-cell and cell...

  5. Posterior hyaloid detachment and internal limiting membrane peeling assisted by anthocyanins from acai fruit (Euterpe oleracea) and 10 other natural vital dyes: experimental study in cadaveric eyes.

    PubMed

    Chen, Jane; Ferreira, Magno Antonio; Farah, Michel Eid; de Carvalho, André Maia; Alves Ferreira, Raquel Eustaquio; de Moraes Filho, Milton Nunes; Souza Lima-Filho, Acácio Alves; Lago, João Henrique G; Sartorelli, Patricia; Rodrigues, Eduardo Buchele; Ferreira, Eber; Peris, Cristiane; Maia, Maurício

    2013-01-01

    The purpose of this study was to determine whether natural dyes facilitate posterior hyaloid detachment (posterior vitreous detachment [PVD]) and retinal internal limiting membrane (ILM) peeling in human eyes. Open-sky vitrectomy with posterior hyaloid and ILM removal was performed in 86 human cadaveric eyes. After core vitrectomy, 11 different dyes were injected into the vitreous cavity to aid hyaloid detachment and ILM removal. The dyes were allowed to settle on the macula for 5 minutes after PVD and were removed by mechanical aspiration. Intraocular forceps were used for ILM peeling, which was confirmed by light microscopy of the peeled tissue. Acai fruit (Euterpe oleracea) extract and 10 additional dyes from plants or animal sources were tested: pomegranate (Punica granatum), logwood (Haematoxylum campechianum), chlorophyll extract from alfalfa (Medicago sativa), cochineal (Dactylopius coccus), hibiscus (Hibiscus rosa-sinensis), indigo (Indigofera tinctoria), paprika (Capiscum annuum), turmeric (Curcuma longa), old fustic (Maclura tinctoria), and grape (Vitis vinifera). The dyes facilitated PVD and ILM peeling. Acai fruit (E. oleracea) extract, logwood (H. campechianum), cochineal (D. coccus), and old fustic (M. tinctoria) facilitated PVD in all cases; dye-assisted PVD was compared with triamcinolone-assisted PVD performed previously in a comparative model. Acai fruit (E. oleracea) extract, cochineal (D. coccus), and chlorophyll extract from alfalfa (M. sativa) showed the best capability for ILM staining; dye-assisted ILM removal was compared with the ILM peeling guided by indocyanine green staining performed previously in a comparative model. Light microscopy confirmed the ILM removal in all cases. Anthocyanin dye of the acai fruit (E. oleracea) and the dyes from cochineal (D. coccus) and chlorophyll extract from alfalfa (M. sativa) resulted in the best capability for posterior hyaloid and ILM staining in human cadaveric eyes and may be a useful tool for vitreoretinal surgery.

  6. Clusterin in the eye: An old dog with new tricks at the ocular surface.

    PubMed

    Fini, M Elizabeth; Bauskar, Aditi; Jeong, Shinwu; Wilson, Mark R

    2016-06-01

    The multifunctional protein clusterin (CLU) was first described in 1983 as a secreted glycoprotein present in ram rete testis fluid that enhanced aggregation ('clustering') of a variety of cells in vitro. It was also independently discovered in a number of other systems. By the early 1990s, CLU was known under many names and its expression had been demonstrated throughout the body, including in the eye. Its homeostatic activities in proteostasis, cytoprotection, and anti-inflammation have been well documented, however its roles in health and disease are still not well understood. CLU is prominent at fluid-tissue interfaces, and in 1996 it was demonstrated to be the most highly expressed transcript in the human cornea, the protein product being localized to the apical layers of the mucosal epithelia of the cornea and conjunctiva. CLU protein is also present in human tears. Using a preclinical mouse model for desiccating stress that mimics human dry eye disease, the authors recently demonstrated that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration in the tears. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to LGALS3 (galectin-3), a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. CLU depletion from the ocular surface epithelia is seen in a variety of inflammatory conditions in humans and mice that lead to squamous metaplasia and a keratinized epithelium. This suggests that CLU might have a specific role in maintaining mucosal epithelial differentiation, an idea that can now be tested using the mouse model for desiccating stress. Most excitingly, the new findings suggest that CLU could serve as a novel biotherapeutic for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Dynamic Features for Iris Recognition.

    PubMed

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  8. Microgravity

    NASA Image and Video Library

    2003-01-22

    One concern about human adaptation to space is how returning from the microgravity of orbit to Earth can affect an astronaut's ability to fly safely. There are monitors and infrared video cameras to measure eye movements without having to affect the crew member. A computer screen provides moving images which the eye tracks while the brain determines what it is seeing. A video camera records movement of the subject's eyes. Researchers can then correlate perception and response. Test subjects perceive different images when a moving object is covered by a mask that is visible or invisible (above). Early results challenge the accepted theory that smooth pursuit -- the fluid eye movement that humans and primates have -- does not involve the higher brain. NASA results show that: Eye movement can predict human perceptual performance, smooth pursuit and saccadic (quick or ballistic) movement share some signal pathways, and common factors can make both smooth pursuit and visual perception produce errors in motor responses.

  9. Understanding Visible Perception

    NASA Technical Reports Server (NTRS)

    2003-01-01

    One concern about human adaptation to space is how returning from the microgravity of orbit to Earth can affect an astronaut's ability to fly safely. There are monitors and infrared video cameras to measure eye movements without having to affect the crew member. A computer screen provides moving images which the eye tracks while the brain determines what it is seeing. A video camera records movement of the subject's eyes. Researchers can then correlate perception and response. Test subjects perceive different images when a moving object is covered by a mask that is visible or invisible (above). Early results challenge the accepted theory that smooth pursuit -- the fluid eye movement that humans and primates have -- does not involve the higher brain. NASA results show that: Eye movement can predict human perceptual performance, smooth pursuit and saccadic (quick or ballistic) movement share some signal pathways, and common factors can make both smooth pursuit and visual perception produce errors in motor responses.

  10. Proposed new classification scheme for chemical injury to the human eye.

    PubMed

    Bagley, Daniel M; Casterton, Phillip L; Dressler, William E; Edelhauser, Henry F; Kruszewski, Francis H; McCulley, James P; Nussenblatt, Robert B; Osborne, Rosemarie; Rothenstein, Arthur; Stitzel, Katherine A; Thomas, Karluss; Ward, Sherry L

    2006-07-01

    Various ocular alkali burn classification schemes have been published and used to grade human chemical eye injuries for the purpose of identifying treatments and forecasting outcomes. The ILSI chemical eye injury classification scheme was developed for the additional purpose of collecting detailed human eye injury data to provide information on the mechanisms associated with chemical eye injuries. This information will have clinical application, as well as use in the development and validation of new methods to assess ocular toxicity. A panel of ophthalmic researchers proposed the new classification scheme based upon current knowledge of the mechanisms of eye injury, and their collective clinical and research experience. Additional ophthalmologists and researchers were surveyed to critique the scheme. The draft scheme was revised, and the proposed scheme represents the best consensus from at least 23 physicians and scientists. The new scheme classifies chemical eye injury into five categories based on clinical signs, symptoms, and expected outcomes. Diagnostic classification is based primarily on two clinical endpoints: (1) the extent (area) of injury at the limbus, and (2) the degree of injury (area and depth) to the cornea. The new classification scheme provides a uniform system for scoring eye injury across chemical classes, and provides enough detail for the clinician to collect data that will be relevant to identifying the mechanisms of ocular injury.

  11. 75 FR 74068 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; U10 Teleconference... applications. Place: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852. (Telephone Confence Call...

  12. 77 FR 24727 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Trials.... Schaffner, Ph.D., Chief, Scientific Review Branch, Division of Extramural Research, National Eye Institute...

  13. 76 FR 24498 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...

  14. 76 FR 66732 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Genomic Research.... Schaffner, PhD, Chief, Scientific Review Officer, Division of Extramural Research, National Eye Institute...

  15. 77 FR 43097 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Epidemiology... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  16. 78 FR 62639 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical and.... Contact Person: Brian Hoshaw, Ph.D., Scientific Review Officer, National Eye Institute, National...

  17. 75 FR 58410 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-24

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NIH Joint Neuroscience... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  18. 77 FR 73666 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Trial... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  19. 76 FR 71350 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Pediatric Vision..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...

  20. 77 FR 22581 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Loan Repayment... program applications. Place: National Eye Institute, National Institutes of Health, 5635 Fishers Lane...

  1. 75 FR 26968 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Loan Repayment... applications. Place: National Eye Institute, 5635 Fishers Lane, Bethesda, MD (Virtual Meeting). Contact Person...

  2. 78 FR 62640 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Bioinformatics..., Division of Extramural Research, National Eye Institute, 5635 Fishers Lane, Suite 1300, MSC 9300, Bethesda...

  3. 76 FR 46822 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel... Review Officer, Division of Extramural Research, National Eye Institute, National Institutes of Health...

  4. 78 FR 37556 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Epidemiology and... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  5. 76 FR 39406 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Research Program... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  6. 76 FR 13197 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Clinical... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...

  7. 77 FR 64525 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI Career Development... Schaffner, Ph.D., Chief, Scientific Review Officer, Division of Extramural Research, National Eye Institute...

  8. 75 FR 55806 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, RO1 Epidemiology... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  9. 75 FR 46951 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Division of Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane...

  10. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    EPA Science Inventory

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  11. Does direct human eye contact function as a warning cue for domestic sheep (Ovis aries)?

    PubMed

    Beausoleil, Ngaio J; Stafford, Kevin J; Mellor, David J

    2006-08-01

    Direct eye contact may function as a warning cue during interspecific interactions, and human staring has been shown to influence the behavior of many species. The authors used an arena test to assess whether human staring altered the behavior of domestic sheep (Ovis aries) compared with no human eye contact. Sheep glanced at the staring human's face more often in the first 2 min of the test, indicating that they perceived a difference between the human stimuli. Staring also elicited more locomotor activity and urination than averted gaze. However, there were no differences in fear-related behaviors, suggesting that a staring human did not represent a greater immediate threat than a nonwatching human. These results imply that human staring is a warning cue for domestic sheep, but no more. Without further reinforcement, sheep quickly habituated to the warning cue. ((c) 2006 APA, all rights reserved).

  12. Comparison between beta radiation dose distribution due to LDR and HDR ocular brachytherapy applicators using GATE Monte Carlo platform.

    PubMed

    Mostafa, Laoues; Rachid, Khelifi; Ahmed, Sidi Moussa

    2016-08-01

    Eye applicators with 90Sr/90Y and 106Ru/106Rh beta-ray sources are generally used in brachytherapy for the treatment of eye diseases as uveal melanoma. Whenever, radiation is used in treatment, dosimetry is essential. However, knowledge of the exact dose distribution is a critical decision-making to the outcome of the treatment. The Monte Carlo technique provides a powerful tool for calculation of the dose and dose distributions which helps to predict and determine the doses from different shapes of various types of eye applicators more accurately. The aim of this work consisted in using the Monte Carlo GATE platform to calculate the 3D dose distribution on a mathematical model of the human eye according to international recommendations. Mathematical models were developed for four ophthalmic applicators, two HDR 90Sr applicators SIA.20 and SIA.6, and two LDR 106Ru applicators, a concave CCB model and a flat CCB model. In present work, considering a heterogeneous eye phantom and the chosen tumor, obtained results with the use of GATE for mean doses distributions in a phantom and according to international recommendations show a discrepancy with respect to those specified by the manufacturers. The QC of dosimetric parameters shows that contrarily to the other applicators, the SIA.20 applicator is consistent with recommendations. The GATE platform show that the SIA.20 applicator present better results, namely the dose delivered to critical structures were lower compared to those obtained for the other applicators, and the SIA.6 applicator, simulated with MCNPX generates higher lens doses than those generated by GATE. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Genotypes of JC virus, DNA of cytomegalovirus, and proviral DNA of human immunodeficiency virus in eyes of acquired immunodeficiency syndrome patients.

    PubMed

    Eberwein, Philipp; Hansen, Lutz L; Agostini, Hansjürgen T

    2005-02-01

    JC virus (JCV) is a human polyomavirus that exists in at least eight different genotypes as a result of coevolution with different human populations all over the world. Well adapted to its host, it usually persists in the kidneys and possibly the brain. If the host becomes immunodeficient, JCV can cause the fatal demyelinating disease progressive multifocal leukoencephalopathy (PML). There is increasing evidence that JCV is transactivated by cytomegalovirus (CMV) and the human immunodeficiency virus (HIV). Both CMV and HIV can infect the retina of acquired immunodeficiency syndrome (AIDS) patients, causing severe necrosis in the case of CMV retinitis or a mild HIV-associated vasculopathy, with bleeding and cotton wool spots. The authors therefore investigated by polymerase chain reaction (PCR) whether DNA of these three viruses was detectable in paraffin-embedded eyes of AIDS patients with a clinical history of CMV retinitis. From a total of 65 eyes, JCV was detected in 21 (32%). Thirty-six (55%) were positive for CMV and 6 (9%) for proviral DNA of HIV. JCV and CMV were found in 13 eyes, JCV and HIV in 3 eyes, CMV and HIV in 1 eye, and DNA from all three viruses in 1 eye. The JCV genotypes were types 1A, 2A, 2E, 3, and 4. In 21 eyes of patients without AIDS, only one sample was JCV positive. In conclusion, JCV DNA can be detected in ocular tissue of AIDS patients at a significantly higher level than in eyes of nonimmunosuppressed patients. Further investigations will help to decide if JCV contributes to the retinopathy caused by CMV and HIV.

  14. Abnormal spatial frequency channels in esotropic cats.

    PubMed

    Holopigian, K; Blake, R

    1984-01-01

    A noise masking paradigm was used to measure spatial tuning for the deviating and nondeviating eyes of two esotropic cats and for one eye of a control cat. With increasing noise contrast, masking grew more slowly for both the deviating and the nondeviating eyes of the esotropic cats than for the control cat; apparently, contrast coding is impaired for both eyes of the esotropic cats. Masking with band-reject filtered noise indicated that detection channels for either eye of the esotropic cats were twice as broadly tuned as those for the control cat. In a subsequent experiment, the spatial tuning characteristics of two human esotropes were found to be normal, indicating a fundamental difference between human esotropia and esotropia induced in cats by the section of an eye muscle.

  15. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction

    PubMed Central

    XU, TIAN (LINGER); ZHANG, HUI; YU, CHEN

    2016-01-01

    We focus on a fundamental looking behavior in human-robot interactions – gazing at each other’s face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user’s face as a response to the human’s gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot’s gaze toward the human partner’s face in real time and then analyzed the human’s gaze behavior as a response to the robot’s gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot’s face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained. PMID:28966875

  16. Through their eyes: The influence of social models on attention and memory in capuchin monkeys (Sapajus apella).

    PubMed

    Howard, Lauren H; Festa, Cassandra; Lonsdorf, Elizabeth V

    2018-05-01

    The ability to learn socially is of critical importance across a wide variety of species, as it allows knowledge to be passed quickly among individuals without the need of time-consuming trial-and-error learning. Among primates, social learning research has been particularly focused on foraging tasks, including transmission dynamics and the demonstration characteristics that appear to support social learning. Less work has focused on the attentional salience of the information being viewed, especially in New World monkeys. We used a noninvasive eye-tracking paradigm previously used in human infants and great apes to examine the salience of social modeling for memory in capuchin monkeys. Like human infants and apes, capuchins were significantly more likely to remember an event that included a social model as opposed to a nonsocial model. This article provides some of the first evidence that capuchin memory is altered by the presence of a social model and presents a novel method for assessing cognitive capabilities in this species. Whether this "social memory bias" is shared across the primate order, or is present only in taxa that regularly rely on social information, is an important avenue for future research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. Common determinants of body size and eye size in chickens from an advanced intercross line.

    PubMed

    Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; Fan, Qiao; Saw, Seang Mei; Guggenheim, Jeremy A

    2009-06-15

    Myopia development is characterised by an increased axial eye length. Therefore, identifying factors that influence eye size may provide new insights into the aetiology of myopia. In humans, axial length is positively correlated to height and weight, and in mice, eye weight is positively correlated with body weight. The purpose of this study was to examine the relationship between eye size and body size in chickens from a genetic cross in which alleles with major effects on eye and body size were segregating. Chickens from a cross between a layer line (small body size and eye size) and a broiler line (large body and eye size) were interbred for 10 generations so that alleles for eye and body size would have the chance to segregate independently. At 3 weeks of age, 510 chicks were assessed using in vivo high resolution A-scan ultrasonography and keratometry. Equatorial eye diameter and eye weight were measured after enucleation. The variations in eye size parameters that could be explained by body weight (BW), body length (BL), head width (HW) and sex were examined using multiple linear regression. It was found that BW, BL and HW and sex together predicted 51-56% of the variation in eye weight, axial length, corneal radius, and equatorial eye diameter. By contrast, the same variables predicted only 22% of the variation in lens thickness. After adjusting for sex, the three body size parameters predicted 45-49% of the variation in eye weight, axial length, corneal radius, and eye diameter, but only 0.4% of the variation in lens thickness. In conclusion, about half of the variation in eye size in the chickens of this broiler-layer advanced intercross line is likely to be determined by pleiotropic genes that also influence body size. Thus, mapping the quantitative trait loci (QTL) that determine body size may be useful in understanding the genetic determination of eye size (a logical inference of this result is that the 20 or more genetic variants that have recently been shown to influence human height may also be found to influence axial eye length). Furthermore, adjusting for body size will be essential in mapping pure eye size QTL in this chicken population, and may also have value in mapping eye size QTL in humans.

  18. 77 FR 27784 - Announcement of National Eye Institute Participation in PA-11-347, “NINDS SBIR Technology...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Announcement of National Eye... intended to inform potential applicants that the National Eye Institute (NEI) is participating in PA-11-347... biology related to eye health and eye disease treatments. For more information about the research and...

  19. 76 FR 3917 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Training Grants. Date...: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852 (Virtual Meeting). Contact Person: Daniel R...

  20. 78 FR 28233 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute..., National Eye Institute. The meeting will be closed to the public in accordance with the provisions set... individual intramural programs and projects conducted by the National Eye Institute, including consideration...

  1. 78 FR 9403 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Core Grant (P30... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  2. 77 FR 63845 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI-RFA Stem Cell... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  3. 75 FR 33628 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel... Review Officer, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC...

  4. 77 FR 14816 - National Eye Institute Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES NATIONAL INSTITUTES OF HEALTH National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; Vision Research Grant..., National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300, 301-451...

  5. 75 FR 10489 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Clinical Grant..., Division of Extramural Research, National Eye Institute, 5635 Fishers Lane, Suite 1300, Msc 9300, Bethesda...

  6. 75 FR 8971 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NEI K99 Grant.... Kenshalo, PhD, Scientific Review Officer, National Eye Institute, National Institutes of Health, 5635...

  7. 78 FR 15021 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Pathways to... Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300...

  8. 77 FR 40367 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel..., Washington, DC 20015. Contact Person: Daniel R. Kenshalo, Ph.D., Scientific Review Officer, National Eye...

  9. 75 FR 64311 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, NIH Training Grants..., National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300, MSC 9300. 301-451...

  10. 78 FR 46593 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI K99 Review. Date... Person: Brian Hoshaw, Ph.D. Scientific Review Officer, National Eye Institute, National Institutes of...

  11. Correlation between human observer performance and model observer performance in differential phase contrast CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ke; Garrett, John; Chen, Guang-Hong

    2013-11-15

    Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objectsmore » (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD curves tended to be steeper. The CHO generated the best quantitative agreement with human observers with its CD curve overlapping with that of human observer. Statistical equivalence between CHO and humans can be claimed within 11% of the human observer results, including both the disk and lesion detection experiments.Conclusions: The model observer method can be used to accurately represent human observer performance with the stochastic DPC-CT noise for SKE tasks with sizes ranging from 8 to 128 pixels. The incorporation of the anatomical noise remains to be studied.« less

  12. Looking to the eyes influences the processing of emotion on face-sensitive event-related potentials in 7-month-old infants.

    PubMed

    Vanderwert, Ross E; Westerlund, Alissa; Montoya, Lina; McCormick, Sarah A; Miguel, Helga O; Nelson, Charles A

    2015-10-01

    Previous studies in infants have shown that face-sensitive components of the ongoing electroencephalogram (the event-related potential, or ERP) are larger in amplitude to negative emotions (e.g., fear, anger) versus positive emotions (e.g., happy). However, it is still unclear whether the negative emotions linked with the face or the negative emotions alone contribute to these amplitude differences. We simultaneously recorded infant looking behaviors (via eye-tracking) and face-sensitive ERPs while 7-month-old infants viewed human faces or animals displaying happy, fear, or angry expressions. We observed that the amplitude of the N290 was greater (i.e., more negative) to angry animals compared to happy or fearful animals; no such differences were obtained for human faces. Eye-tracking data highlighted the importance of the eye region in processing emotional human faces. Infants that spent more time looking to the eye region of human faces showing fearful or angry expressions had greater N290 or P400 amplitudes, respectively. © 2014 Wiley Periodicals, Inc.

  13. The visual development of hand-centered receptive fields in a neural network model of the primate visual system trained with experimentally recorded human gaze changes

    PubMed Central

    Galeazzi, Juan M.; Navajas, Joaquín; Mender, Bedeho M. W.; Quian Quiroga, Rodrigo; Minini, Loredana; Stringer, Simon M.

    2016-01-01

    ABSTRACT Neurons have been found in the primate brain that respond to objects in specific locations in hand-centered coordinates. A key theoretical challenge is to explain how such hand-centered neuronal responses may develop through visual experience. In this paper we show how hand-centered visual receptive fields can develop using an artificial neural network model, VisNet, of the primate visual system when driven by gaze changes recorded from human test subjects as they completed a jigsaw. A camera mounted on the head captured images of the hand and jigsaw, while eye movements were recorded using an eye-tracking device. This combination of data allowed us to reconstruct the retinal images seen as humans undertook the jigsaw task. These retinal images were then fed into the neural network model during self-organization of its synaptic connectivity using a biologically plausible trace learning rule. A trace learning mechanism encourages neurons in the model to learn to respond to input images that tend to occur in close temporal proximity. In the data recorded from human subjects, we found that the participant’s gaze often shifted through a sequence of locations around a fixed spatial configuration of the hand and one of the jigsaw pieces. In this case, trace learning should bind these retinal images together onto the same subset of output neurons. The simulation results consequently confirmed that some cells learned to respond selectively to the hand and a jigsaw piece in a fixed spatial configuration across different retinal views. PMID:27253452

  14. The visual development of hand-centered receptive fields in a neural network model of the primate visual system trained with experimentally recorded human gaze changes.

    PubMed

    Galeazzi, Juan M; Navajas, Joaquín; Mender, Bedeho M W; Quian Quiroga, Rodrigo; Minini, Loredana; Stringer, Simon M

    2016-01-01

    Neurons have been found in the primate brain that respond to objects in specific locations in hand-centered coordinates. A key theoretical challenge is to explain how such hand-centered neuronal responses may develop through visual experience. In this paper we show how hand-centered visual receptive fields can develop using an artificial neural network model, VisNet, of the primate visual system when driven by gaze changes recorded from human test subjects as they completed a jigsaw. A camera mounted on the head captured images of the hand and jigsaw, while eye movements were recorded using an eye-tracking device. This combination of data allowed us to reconstruct the retinal images seen as humans undertook the jigsaw task. These retinal images were then fed into the neural network model during self-organization of its synaptic connectivity using a biologically plausible trace learning rule. A trace learning mechanism encourages neurons in the model to learn to respond to input images that tend to occur in close temporal proximity. In the data recorded from human subjects, we found that the participant's gaze often shifted through a sequence of locations around a fixed spatial configuration of the hand and one of the jigsaw pieces. In this case, trace learning should bind these retinal images together onto the same subset of output neurons. The simulation results consequently confirmed that some cells learned to respond selectively to the hand and a jigsaw piece in a fixed spatial configuration across different retinal views.

  15. Research on metallic material defect detection based on bionic sensing of human visual properties

    NASA Astrophysics Data System (ADS)

    Zhang, Pei Jiang; Cheng, Tao

    2018-05-01

    Due to the fact that human visual system can quickly lock the areas of interest in complex natural environment and focus on it, this paper proposes an eye-based visual attention mechanism by simulating human visual imaging features based on human visual attention mechanism Bionic Sensing Visual Inspection Model Method to Detect Defects of Metallic Materials in the Mechanical Field. First of all, according to the biologically visually significant low-level features, the mark of defect experience marking is used as the intermediate feature of simulated visual perception. Afterwards, SVM method was used to train the advanced features of visual defects of metal material. According to the weight of each party, the biometrics detection model of metal material defect, which simulates human visual characteristics, is obtained.

  16. Modeling eye movements in visual agnosia with a saliency map approach: bottom-up guidance or top-down strategy?

    PubMed

    Foulsham, Tom; Barton, Jason J S; Kingstone, Alan; Dewhurst, Richard; Underwood, Geoffrey

    2011-08-01

    Two recent papers (Foulsham, Barton, Kingstone, Dewhurst, & Underwood, 2009; Mannan, Kennard, & Husain, 2009) report that neuropsychological patients with a profound object recognition problem (visual agnosic subjects) show differences from healthy observers in the way their eye movements are controlled when looking at images. The interpretation of these papers is that eye movements can be modeled as the selection of points on a saliency map, and that agnosic subjects show an increased reliance on visual saliency, i.e., brightness and contrast in low-level stimulus features. Here we review this approach and present new data from our own experiments with an agnosic patient that quantifies the relationship between saliency and fixation location. In addition, we consider whether the perceptual difficulties of individual patients might be modeled by selectively weighting the different features involved in a saliency map. Our data indicate that saliency is not always a good predictor of fixation in agnosia: even for our agnosic subject, as for normal observers, the saliency-fixation relationship varied as a function of the task. This means that top-down processes still have a significant effect on the earliest stages of scanning in the setting of visual agnosia, indicating severe limitations for the saliency map model. Top-down, active strategies-which are the hallmark of our human visual system-play a vital role in eye movement control, whether we know what we are looking at or not. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Design and characterization of a tunable opto-mechatronic system to mimic the focusing and the regulation of illumination in the formation of images made by the human eye

    NASA Astrophysics Data System (ADS)

    Santiago-Alvarado, A.; Cruz-Félix, A.; Hernández Méndez, A.; Pérez-Maldonado, Y.; Domínguez-Osante, C.

    2015-05-01

    Tunable lenses have attracted much attention due to their potential applications in such areas like machine vision, laser projection, ophthalmology, etc. In this work we present the design of a tunable opto-mechatronic system capable of focusing and to regulate the entrance illumination that mimics the performance made by the iris and the crystalline lens of the human eye. A solid elastic lens made of PDMS has been used in order to mimic the crystalline lens and an automatic diaphragm has been used to mimic the iris of the human eye. Also, a characterization of such system has been performed with standard values of luminosity for the human eye have been taken into account to calibrate and to validate the entrance illumination levels to the overall optical system.

  18. Eye gazing direction inspection based on image processing technique

    NASA Astrophysics Data System (ADS)

    Hao, Qun; Song, Yong

    2005-02-01

    According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.

  19. Molecular medicine in ophthalmic care.

    PubMed

    Richer, Stuart; Stiles, William; Thomas, Carla

    2009-12-01

    Lipofuscin is the most consistent and phylogenically constant morphologic marker of cellular aging. Autofluorescence of the A2E fluorophore within retinal pigment epithelial (RPE) lipofuscin affords the opportunity for noninvasive evaluation of age- and disease-related pathophysiological changes in the human retina. It is being used in National Eye Institute/Age-Related Eye Disease Study II to evaluate age-related macular degeneration (AMD) geographic atrophy expansion. Experiments show lipofuscin can be reversed in cell culture and animal models in heart, brain, spinal cord, and retinal tissues, using an array of antioxidants and iron chelators. An 80-year-old man with a gastric resection presented with complaints of unremitting night driving difficulty despite treatment with lutein and omega III fatty acids. Notable parafoveal deposition of retinal lipofuscin by 50 degrees fundus auto-fluorescence (580 nm excitation/660 barrier filters) and concurrent abnormalities in non-Snellen measures of visual function-Contrast Sensitivity Function, 6.5 degrees large field tritan threshold, 10 degrees threshold visual fields, and deficits in the National Institutes of Health/National Eye Institute Visual Function Questionnaire (VFQ) 25 subjective night driving/mental health subscale questionnaire were obtained. The patient was placed on an over-the-counter daily oral polyphenolic mixture containing resveratrol and re-evaluated 5 months later. The data reveal improvements in all measures of visual function, subjective improvement in vision and mental functioning on the VFQ 25, and visible clearing of RPE lipofuscin. To our knowledge, we believe this to be the first reported human clinical case of lipofuscin reversal in the human eye correlated with measured clinical and subjective improvement in visual and mental function after nutraceutical intervention.

  20. Morphological study of the eye and adnexa in capuchin monkeys (Sapajus sp.)

    PubMed Central

    Silva, Danielle Nascimento; Oriá, Arianne Pontes; Araujo, Nayone Lantyer; Martins-Filho, Emanoel; Muramoto, Caterina; Libório, Fernanda de Azevedo

    2017-01-01

    The objective of this study was to describe the anatomic and histologic features of the Sapajus sp. eye, comparing similarities and differences of humans and other species of non-human primates for biomedical research purposes. Computed tomography (CT) of adnexa, eye and orbit live animal, as well as formolized pieces of the same structures of Sapajus sp. for anatomical and histological study were also performed. The anatomical description of the eye and adnexa was performed using the techniques of topographic dissection and exenteration. Histological fragments were fixated in buffered formalin 10%, processed by the routine paraffin inclusion technique, stained with hematoxylin-eosin and special stains. CT scan evaluation showed no differences between the live animal and the formolized head on identification of visual apparatus structures. Anatomic and histologic evaluation revealed rounded orbit, absence of the supraorbital foramen and frontal notch, little exposure of the sclera, with slight pigmentation of the exposed area and marked pigmentation at the sclerocorneal junction. Masson's Trichrome revealed the Meibomian glands, the corneal epithelium and Bowman's membrane; in the choroid, melanocytes and Bruch's membrane were observed; and in the retina, cones and rods as well as, optic nerve, the lamina cribrosa of the nerve fibers bundles. Toluidine blue highlighted the membranes: Bowman, Descemet and the endothelium; in the choroid: melanocytes; and in the retina: nuclear layers and retinal pigment epithelium. In view of the observed results Sapajus sp. is an important experimental model for research in the ophthalmology field, which has been shown due to the high similarity of its anatomical and histological structures with the human species. PMID:29206882

  1. New paradigms for understanding and step changes in treating active and chronic, persistent apicomplexan infections

    USDA-ARS?s Scientific Manuscript database

    Toxoplasma gondii, the most common parasitic infection of the human brain and eye, persists across lifetimes, can progressively damage sight, and is currently incurable. New, curative medicines are needed urgently. Herein, we developed novel models to facilitate drug development: EGS strain T. gondi...

  2. Computer Simulations for Lab Experiences in Secondary Physics

    ERIC Educational Resources Information Center

    Murphy, David Shannon

    2012-01-01

    Physical science instruction often involves modeling natural systems, such as electricity that possess particles which are invisible to the unaided eye. The effect of these particles' motion is observable, but the particles are not directly observable to humans. Simulations have been developed in physics, chemistry and biology that, under certain…

  3. Two Variants in SLC24A5 Are Associated with “Tiger-Eye” Iris Pigmentation in Puerto Rican Paso Fino Horses

    PubMed Central

    Mack, Maura; Kowalski, Elizabeth; Grahn, Robert; Bras, Dineli; Penedo, Maria Cecilia T.; Bellone, Rebecca

    2017-01-01

    A unique eye color, called tiger-eye, segregates in the Puerto Rican Paso Fino (PRPF) horse breed and is characterized by a bright yellow, amber, or orange iris. Pedigree analysis identified a simple autosomal recessive mode of inheritance for this trait. A genome-wide association study (GWAS) with 24 individuals identified a locus on ECA 1 reaching genome-wide significance (Pcorrected = 1.32 × 10−5). This ECA1 locus harbors the candidate gene, Solute Carrier Family 24 (Sodium/Potassium/Calcium Exchanger), Member 5 (SLC24A5), with known roles in pigmentation in humans, mice, and zebrafish. Humans with compound heterozygous mutations in SLC24A5 have oculocutaneous albinism (OCA) type 6 (OCA6), which is characterized by dilute skin, hair, and eye pigmentation, as well as ocular anomalies. Twenty tiger-eye horses were homozygous for a nonsynonymous mutation in exon 2 (p.Phe91Tyr) of SLC24A5 (called here Tiger-eye 1), which is predicted to be deleterious to protein function. Additionally, eight of the remaining 12 tiger-eye horses heterozygous for the p.Phe91Tyr variant were also heterozygous for a 628 bp deletion encompassing all of exon 7 of SLC24A5 (c.875-340_1081+82del), which we will call here the Tiger-eye 2 allele. None of the 122 brown-eyed horses were homozygous for either tiger-eye-associated allele or were compound heterozygotes. Further, neither variant was detected in 196 horses from four related breeds not known to have the tiger-eye phenotype. Here, we propose that two mutations in SLC24A5 affect iris pigmentation in tiger-eye PRPF horses. Further, unlike OCA6 in humans, the Tiger-eye 1 mutation in its homozygous state or as a compound heterozygote (Tiger-eye 1/Tiger-eye 2) does not appear to cause ocular anomalies or a change in coat color in the PRPF horse. PMID:28655738

  4. A mouse dry eye model induced by topical administration of benzalkonium chloride.

    PubMed

    Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui; Liu, Zuguo

    2011-01-25

    To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompaniment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye.

  5. A mouse dry eye model induced by topical administration of benzalkonium chloride

    PubMed Central

    Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui

    2011-01-01

    Purpose To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. Methods BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. Results BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompanyment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Conclusions Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye. PMID:21283525

  6. Proliferative vitreoretinopathy in the Swine-a new model.

    PubMed

    Umazume, Kazuhiko; Barak, Yoreh; McDonald, Kevin; Liu, Lanhsin; Kaplan, Henry J; Tamiya, Shigeo

    2012-07-24

    To develop a large animal model of proliferative vitreoretinopathy (PVR) in the swine to eventually study disease pathophysiology, as well as novel therapies. PVR was induced in domestic swine by creation of a posterior vitreous detachment, creation of a retinal detachment by the injection of subretinal fluid, and intravitreal injection of green fluorescent protein-positive retinal pigment epithelial (GFP+ RPE) cells. Control eyes had the same surgical procedures without RPE cell injection. PVR was clinically graded on days 3, 7, and 14. Animals were euthanized on day 14, and enucleated eyes were analyzed by light microscopy and immunohistochemistry. Injection of GFP+ RPE cells into the vitreous cavity produced localized, traction retinal detachments by day 14 in all eyes (14 of 14); in contrast, the retina spontaneously reattached by day 3 and remained attached in all control eyes (10 of 10). Contractile epiretinal membranes on the inner retinal surface that caused the traction retinal detachments consisted predominantly of GFP+ RPE cells. These cells stained positive for cytokeratin, confirming their epithelial origin, and also expressed α-SMA and fibronectin, markers for myofibroblasts and fibrosis, respectively. We established a swine PVR model that recapitulates key clinical features found in humans and, thus, can be used to study the pathophysiology of PVR, as well as new novel therapies. GFP+ RPE cells injected into the vitreous cavity formed contractile membranes on the inner retinal surface and caused localized traction retinal detachments.

  7. An amodal shared resource model of language-mediated visual attention

    PubMed Central

    Smith, Alastair C.; Monaghan, Padraic; Huettig, Falk

    2013-01-01

    Language-mediated visual attention describes the interaction of two fundamental components of the human cognitive system, language and vision. Within this paper we present an amodal shared resource model of language-mediated visual attention that offers a description of the information and processes involved in this complex multimodal behavior and a potential explanation for how this ability is acquired. We demonstrate that the model is not only sufficient to account for the experimental effects of Visual World Paradigm studies but also that these effects are emergent properties of the architecture of the model itself, rather than requiring separate information processing channels or modular processing systems. The model provides an explicit description of the connection between the modality-specific input from language and vision and the distribution of eye gaze in language-mediated visual attention. The paper concludes by discussing future applications for the model, specifically its potential for investigating the factors driving observed individual differences in language-mediated eye gaze. PMID:23966967

  8. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging.

    PubMed

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R

    2015-12-15

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A , 1985, 2 .] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  9. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging

    NASA Astrophysics Data System (ADS)

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.

    2015-12-01

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  10. Co-culture of human bone marrow mesenchymal stem cells and macrophages attenuates lipopolysaccharide-induced inflammation in human corneal epithelial cells.

    PubMed

    Jeong, Won-Yong; Kim, Ji-Hye; Kim, Chan-Wha

    2018-05-01

    Dry eye syndrome (DES) is considered as an ocular surface inflammatory disease. Previous studies have shown inflammation plays an important role in the progression and onset of DES. Co-culture of human bone marrow mesenchymal stem cells (HBMSCs) and macrophages showed immunomodulatory effects via regulation of cytokine regulation. Thus, the aim of this study was to investigate the effect of the interaction of these cells on in vitro DES model. The conditioned media (CM) from macrophages, HBMSCs, and HBMSCs + macrophages were treated to human corneal epithelial cells, which showed significant reduction in IL-1α and IL-1β expression levels in HBMSCs + macrophages group. Moreover, the IL-1 Receptor Antagonist (IL-1RA) was highly expressed in the CM from the HBMSCs + macrophages group. Wounded eyes of mice were treated with IL-1RA at 0-100 ng/mL for 16 h, the wound size was reduced. The results of this study might lead to the identification of new therapeutic targets for DES.

  11. Live video monitoring robot controlled by web over internet

    NASA Astrophysics Data System (ADS)

    Lokanath, M.; Akhil Sai, Guruju

    2017-11-01

    Future is all about robots, robot can perform tasks where humans cannot, Robots have huge applications in military and industrial area for lifting heavy weights, for accurate placements, for repeating the same task number of times, where human are not efficient. Generally robot is a mix of electronic, electrical and mechanical engineering and can do the tasks automatically on its own or under the supervision of humans. The camera is the eye for robot, call as robovision helps in monitoring security system and also can reach into the places where the human eye cannot reach. This paper presents about developing a live video streaming robot controlled from the website. We designed the web, controlling for the robot to move left, right, front and back while streaming video. As we move to the smart environment or IoT (Internet of Things) by smart devices the system we developed here connects over the internet and can be operated with smart mobile phone using a web browser. The Raspberry Pi model B chip acts as heart for this system robot, the sufficient motors, surveillance camera R pi 2 are connected to Raspberry pi.

  12. 75 FR 48976 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Epi R01s, Data Analysis... Extramural Research, National Eye Institute, National Institutes of Health, 5635 Fishers Lane, Suite 1300...

  13. 75 FR 16818 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Training Grants.... [[Page 16819

  14. Human amygdala activation during rapid eye movements of rapid eye movement sleep: an intracranial study.

    PubMed

    Corsi-Cabrera, María; Velasco, Francisco; Del Río-Portilla, Yolanda; Armony, Jorge L; Trejo-Martínez, David; Guevara, Miguel A; Velasco, Ana L

    2016-10-01

    The amygdaloid complex plays a crucial role in processing emotional signals and in the formation of emotional memories. Neuroimaging studies have shown human amygdala activation during rapid eye movement sleep (REM). Stereotactically implanted electrodes for presurgical evaluation in epileptic patients provide a unique opportunity to directly record amygdala activity. The present study analysed amygdala activity associated with REM sleep eye movements on the millisecond scale. We propose that phasic activation associated with rapid eye movements may provide the amygdala with endogenous excitation during REM sleep. Standard polysomnography and stereo-electroencephalograph (SEEG) were recorded simultaneously during spontaneous sleep in the left amygdala of four patients. Time-frequency analysis and absolute power of gamma activity were obtained for 250 ms time windows preceding and following eye movement onset in REM sleep, and in spontaneous waking eye movements in the dark. Absolute power of the 44-48 Hz band increased significantly during the 250 ms time window after REM sleep rapid eye movements onset, but not during waking eye movements. Transient activation of the amygdala provides physiological support for the proposed participation of the amygdala in emotional expression, in the emotional content of dreams and for the reactivation and consolidation of emotional memories during REM sleep, as well as for next-day emotional regulation, and its possible role in the bidirectional interaction between REM sleep and such sleep disorders as nightmares, anxiety and post-traumatic sleep disorder. These results provide unique, direct evidence of increased activation of the human amygdala time-locked to REM sleep rapid eye movements. © 2016 European Sleep Research Society.

  15. Dynamic light scattering in ophthalmology: results of in vitro and in vivo experiments.

    PubMed

    Fankhauser, Franz

    2006-01-01

    To calibrate new dynamic light scattering (DLS) devices in defined solutions and post mortem porcine and human eyes. To examine all segments of the eye and to become familiar with the usage of the technique in living subjects. METHODS, DESIGN: Three new DLS devices for the usage in patients were developed. Mono-disperse solutions, poly-disperse solutions, gels, post mortem porcine and human eyes as well as healthy volunteers were studied. The detected signals were inverted into autocorrelation functions. We constructed three DLS devices appropriate for in vitro as well as in vivo examinations. In mono disperse solution precise disintegration rates could be calculated. In poly-disperse solutions, in gel and in the vitreous the results did not correlate with movements of individual particles but we could calculate characteristics of the complete scattering system. In vivo measurements demonstrated that DLS can be used in all human eye segments. DLS is a unique technique. With DLS the molecular composition of eye segments can be studied in living subjects. This can be used to understand the molecular basis of severe eye diseases. The presented data demonstrate that DLS delivers reproducible data from all eye segments. It is possible to study the molecular structures of eye segments in living subjects. The developed devices were proved successfully in vitro as well as in vivo. Limitations are the low specificity of DLS and its sensitivity to background noise. Now clinical studies are necessary to demonstrate potential diagnostic benefits of DLS in specific eye diseases.

  16. Genes relacionados con microftalmia y anoftalmia hereditarias.

    PubMed

    Matías-Pérez, Diana; García-Montalvo, Iván Antonio; Zenteno, Juan Carlos

    2017-01-01

    Congenital eye malformations are the second most common cause of childhood blindness and are originated by disruption of the normal process of eye development during embryonic stage. Their etiology is variable, although monogenic causes are of great importance as they have a high risk of familial recurrence. Included among the most severe congenital eye abnormalities are microphthalmia, defined by an abnormally small eye, and anophthalmia, characterized by congenital absence of ocular structures. The currrent knowledge of the genes involved in human microphthalmia and anophthalmia in humans is revised in this work. Copyright: © 2017 SecretarÍa de Salud.

  17. Ensuring Universal Access to Eye Health in Urban Slums in the Global South: The Case of Bhopal (India).

    PubMed

    Pregel, Andrea; Vaughan Gough, Tracy; Jolley, Emma; Buttan, Sandeep; Bhambal, Archana

    2016-01-01

    Sightsavers is an international organisation working with partners in over 30 countries to eliminate avoidable blindness and help people with disabilities participate more fully in society. In the context of its Urban Eye Health Programme in Bhopal (India), the organisation launched a pilot approach aimed at developing an Inclusive Eye Health (IEH) model and IEH Minimum Standards. Accessibility audits were conducted in a tertiary eye hospital and four primary vision centres located within urban slums, addressing the accessibility of physical infrastructures, communication and service provision. The collection and analysis of disaggregated data inform the inclusion strategy and provide a baseline to measure the impact of service provision. Trainings of eye health staff and sensitisation of decision makers on accessibility, Universal Design, disability and gender inclusion are organised on a regular basis. A referral network is being built to ensure participation of women, people with disabilities and other marginalised groups, explore barriers at demand level, and guarantee wider access to eye care in the community. Finally, advocacy interventions will be developed to raise awareness in the community and mainstream disability and gender inclusion within the public health sector. Founded on principles of Universal Design, accessibility and participation, and in line with international human rights treaties, Agenda 2030 and the Sustainable Development Goals (SDGs), Sightsavers' IEH model ultimately aims to develop a sustainable, scalable and universally accessible system-strengthening approach, capable of ensuring more inclusive services to people with disabilities, women and other marginalised groups, and designed to more effectively meet the health needs of the entire population.

  18. CIDER: Enabling Robustness-Power Tradeoffs on a Computational Eyeglass

    PubMed Central

    Mayberry, Addison; Tun, Yamin; Hu, Pan; Smith-Freedman, Duncan; Ganesan, Deepak; Marlin, Benjamin; Salthouse, Christopher

    2016-01-01

    The human eye offers a fascinating window into an individual’s health, cognitive attention, and decision making, but we lack the ability to continually measure these parameters in the natural environment. The challenges lie in: a) handling the complexity of continuous high-rate sensing from a camera and processing the image stream to estimate eye parameters, and b) dealing with the wide variability in illumination conditions in the natural environment. This paper explores the power–robustness tradeoffs inherent in the design of a wearable eye tracker, and proposes a novel staged architecture that enables graceful adaptation across the spectrum of real-world illumination. We propose CIDER, a system that operates in a highly optimized low-power mode under indoor settings by using a fast Search-Refine controller to track the eye, but detects when the environment switches to more challenging outdoor sunlight and switches models to operate robustly under this condition. Our design is holistic and tackles a) power consumption in digitizing pixels, estimating pupillary parameters, and illuminating the eye via near-infrared, b) error in estimating pupil center and pupil dilation, and c) model training procedures that involve zero effort from a user. We demonstrate that CIDER can estimate pupil center with error less than two pixels (0.6°), and pupil diameter with error of one pixel (0.22mm). Our end-to-end results show that we can operate at power levels of roughly 7mW at a 4Hz eye tracking rate, or roughly 32mW at rates upwards of 250Hz. PMID:27042165

  19. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data.

    PubMed

    Ying, Gui-Shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-04-01

    To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field in the elderly. When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI -0.03 to 0.32D, p = 0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, p = 0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller p-values, while analysis of the worse eye provided larger p-values than mixed effects models and marginal models. In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision.

  20. Visual laterality in belugas (Delphinapterus leucas) and Pacific white-sided dolphins (Lagenorhynchus obliquidens) when viewing familiar and unfamiliar humans.

    PubMed

    Yeater, Deirdre B; Hill, Heather M; Baus, Natalie; Farnell, Heather; Kuczaj, Stan A

    2014-11-01

    Lateralization of cognitive processes and motor functions has been demonstrated in a number of species, including humans, elephants, and cetaceans. For example, bottlenose dolphins (Tursiops truncatus) have exhibited preferential eye use during a variety of cognitive tasks. The present study investigated the possibility of visual lateralization in 12 belugas (Delphinapterus leucas) and six Pacific white-sided dolphins (Lagenorhynchus obliquidens) located at two separate marine mammal facilities. During free swim periods, the belugas and Pacific white-sided dolphins were presented a familiar human, an unfamiliar human, or no human during 10-15 min sessions. Session videos were coded for gaze duration, eye presentation at approach, and eye preference while viewing each stimulus. Although we did not find any clear group level lateralization, we found individual left eye lateralized preferences related to social stimuli for most belugas and some Pacific white-sided dolphins. Differences in gaze durations were also observed. The majority of individual belugas had longer gaze durations for unfamiliar rather than familiar stimuli. These results suggest that lateralization occurs during visual processing of human stimuli in belugas and Pacific white-sided dolphins and that these species can distinguish between familiar and unfamiliar humans.

  1. Dwarf Eye Disorder

    ERIC Educational Resources Information Center

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  2. 21 CFR 886.3320 - Eye sphere implant.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Eye sphere implant. 886.3320 Section 886.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3320 Eye sphere implant. (a) Identification. An eye...

  3. 77 FR 12318 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Anterior Eye Disease. Date: March 19, 2012. Time: 1 p.m. to 2:30 p.m. Agenda: To review and...

  4. 75 FR 13769 - National Eye Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; National Eye Institute SBIR Special Emphasis Panel. Date: April 9, 2010. Time: 8:30 a.m. to 5 p.m. Agenda...

  5. 75 FR 20853 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Immunosuppression for Eye Diseases. Date: April 20, 2010. Time: 3 p.m. to 4 p.m. Agenda: To review and evaluate...

  6. 21 CFR 886.3320 - Eye sphere implant.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye sphere implant. 886.3320 Section 886.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3320 Eye sphere implant. (a) Identification. An eye...

  7. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  8. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  9. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  10. The Nine-Step Minnesota Grading System for Eyebank Eyes With Age Related Macular Degeneration: A Systematic Approach to Study Disease Stages.

    PubMed

    Olsen, Timothy W; Liao, Albert; Robinson, Hershonna S; Palejwala, Neal V; Sprehe, Nicholas

    2017-10-01

    To refine the Minnesota Grading System (MGS) using definitions from the Age-Related Eye Disease Studies (AREDS) into a nine-step grading scale (MGS-9). A nine-step grading scale descriptive analysis using three key phenotypic features (total drusen area, increased, and decreased pigmentation) of human eyebank eyes that were graded according to definitions from the AREDS criteria in order to harmonize studies of disease progression for research involving human tissue. From 2005 through February 2017, we have analyzed 1159 human eyes, procured from two eyebanks. Each macula was imaged using high-resolution, stereoscopic color fundus photography with both direct- and transillumination. Fundus images were digitally overlaid with a grading template and triangulated for foveal centration. We documented and stratified risk for each globe by applying the AREDS nine-step grading scale to the key clinical features from the MGS-9. We found a good distribution within the MGS categories (1-9) with few level eight globes. Eyes were processed within 12.1 ± 6.3, hours from the time of death through imaging, dissection, and freezing or fixation. Applying the MGS-9 to 331 pairs (662 eyes were simultaneously graded), 84% were within one-grading step and 93% within two steps of the fellow eye. We also document reticular pseudodrusen, basal laminar drusen, and pattern dystrophy. The MGS nine-step grading scale enables researchers using human tissue to refine the risk assessment of donor tissue. This analysis will harmonize results among researchers when grading human tissue using MGS criteria. Most importantly, the MGS-9 links directly to the known risk for progression from the AREDS.

  11. Effects of light on brain and behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brainard, G.C.

    1994-12-31

    It is obvious that light entering the eye permits the sensory capacity of vision. The human species is highly dependent on visual perception of the environment and consequently, the scientific study of vision and visual mechanisms is a centuries old endeavor. Relatively new discoveries are now leading to an expanded understanding of the role of light entering the eye - in addition to supporting vision, light has various nonvisual biological effects. Over the past thirty years, animal studies have shown that environmental light is the primary stimulus for regulating circadian rhythms, seasonal cycles, and neuroendocrine responses. As with all photobiologicalmore » phenomena, the wavelength, intensity, timing and duration of a light stimulus is important in determining its regulatory influence on the circadian and neuroendocrine systems. Initially, the effects of light on rhythms and hormones were observed only in sub-human species. Research over the past decade, however, has confirmed that light entering the eyes of humans is a potent stimulus for controlling physiological rhythms. The aim of this paper is to examine three specific nonvisual responses in humans which are mediated by light entering the eye: light-induced melatonin suppression, light therapy for winter depression, and enhancement of nighttime performance. This will serve as a brief introduction to the growing database which demonstrates how light stimuli can influence physiology, mood and behavior in humans. Such information greatly expands our understanding of the human eye and will ultimately change our use of light in the human environment.« less

  12. Effects of light on brain and behavior

    NASA Technical Reports Server (NTRS)

    Brainard, George C.

    1994-01-01

    It is obvious that light entering the eye permits the sensory capacity of vision. The human species is highly dependent on visual perception of the environment and consequently, the scientific study of vision and visual mechanisms is a centuries old endeavor. Relatively new discoveries are now leading to an expanded understanding of the role of light entering the eye in addition to supporting vision, light has various nonvisual biological effects. Over the past thirty years, animal studies have shown that environmental light is the primary stimulus for regulating circadian rhythms, seasonal cycles, and neuroendocrine responses. As with all photobiological phenomena, the wavelength, intensity, timing and duration of a light stimulus is important in determining its regulatory influence on the circadian and neuroendocrine systems. Initially, the effects of light on rhythms and hormones were observed only in sub-human species. Research over the past decade, however, has confirmed that light entering the eyes of humans is a potent stimulus for controlling physiological rhythms. The aim of this paper is to examine three specific nonvisual responses in humans which are mediated by light entering the eye: light-induced melatonin suppression, light therapy for winter depression, and enhancement of nighttime performance. This will serve as a brief introduction to the growing database which demonstrates how light stimuli can influence physiology, mood and behavior in humans. Such information greatly expands our understanding of the human eye and will ultimately change our use of light in the human environment.

  13. Gaze-contingent displays: a review.

    PubMed

    Duchowski, Andrew T; Cournia, Nathan; Murphy, Hunter

    2004-12-01

    Gaze-contingent displays (GCDs) attempt to balance the amount of information displayed against the visual information processing capacity of the observer through real-time eye movement sensing. Based on the assumed knowledge of the instantaneous location of the observer's focus of attention, GCD content can be "tuned" through several display processing means. Screen-based displays alter pixel level information generally matching the resolvability of the human retina in an effort to maximize bandwidth. Model-based displays alter geometric-level primitives along similar goals. Attentive user interfaces (AUIs) manage object- level entities (e.g., windows, applications) depending on the assumed attentive state of the observer. Such real-time display manipulation is generally achieved through non-contact, unobtrusive tracking of the observer's eye movements. This paper briefly reviews past and present display techniques as well as emerging graphics and eye tracking technology for GCD development.

  14. Frozen cultured sheets of epidermal keratinocytes in reepithelialization and repair of the cornea after photorefractive keratectomy.

    PubMed

    Castro-Muñozledo, Federico; Ozorno-Zarate, Jorge; Naranjo-Tackman, Ramon; Kuri-Harcuch, Walid

    2002-09-01

    To determine whether frozen cultured sheets of human allogeneic epidermal keratinocytes (CEAK) improved wound repair after experimental corneal ablation by photorefractive keratectomy (PRK). Hospital "Luis Sanchez Bulnes" de la Asociación para Evitar la Ceguera en Mexico, I.A.P, and Department of Cell Biology, CINVESTAV-IPN, Mexico City, Mexico. Transepithelial PRK was performed in the right eye of male albino rabbits to obtain a 112 microm deep and 6.0 mm diameter ablation zone. In 17 eyes, the ablations were covered with frozen CEAK; in 11 eyes, the ablations were covered with a disposable contact lens without the cultured sheets; and in the control group (13 eyes), the ablations were not covered. Subepithelial fibrosis and reepithelialization of the ablated zone were evaluated in serial paraffin-embedded tissue sections from all wounds. Treatment with CEAK reduced fibroblast proliferation and the inflammatory response beneath the ablated zone and produced better organization of the newly formed epithelium by eliminating significant hyperplasia or discontinuities in the periodic acid Shiff-stained basement membrane. It also led to accelerated reepithelialization. The use of frozen CEAK as a biologically active wound dressing improved tissue repair at 1 month in corneas ablated by transepithelial PRK in the male albino rabbit model. Treatment with CEAK could improve the outcome of PRK in humans.

  15. Viscoelastic properties of the posterior eye of normal subjects, patients with age-related macular degeneration, and pigs.

    PubMed

    Zhang, Zhen Huan; Pan, Meng Xin; Cai, Jia Tong; Weiland, James D; Chen, Kinon

    2018-03-26

    The purpose of this study is to measure, characterize, and compare the viscoelastic properties of the posterior eye of advanced dry age-related macular degeneration (AMD) patients, age-matched normal subjects, and pigs (3 groups). Ten horizontal and ten vertical strips of the macula retina and the underneath choroid and sclera were obtained for each group, respectively. They were examined by incremental stress-relaxation cycles in body-temperature saline. Mechanical response was characterized by the quasi-linear viscoelastic model. All the tissues were shown to be nonlinear viscoelastic. Stiffening and isotropization, increased relaxation, and softening and isotropization were found in AMD retina, choroid, and sclera, respectively, which are the mechanical features of the atherosclerotic process. The patients' medical records were in accordance with epidemiological studies indicating a relationship between the advanced AMD and atherosclerotic vascular disease (ASVD). Moreover, many differences were found between the viscoelastic properties of porcine and normal human retina, choroid, and sclera. The results suggest that AMD is associated with ASVD through a mechanism involving abnormal retinal, choroidal, and scleral mechanics similar to those seen in the atherosclerotic process. Moreover, researchers should be aware of mechanical differences when using porcine posterior eyes as a substitute for human posterior eyes. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2018. © 2018 Wiley Periodicals, Inc.

  16. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses.

    PubMed

    Simicevic, Neven

    2008-03-21

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.

  17. Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?

    NASA Astrophysics Data System (ADS)

    De Martini, Francesco

    2010-05-01

    In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.

  18. Stress free configuration of the human eye.

    PubMed

    Elsheikh, Ahmed; Whitford, Charles; Hamarashid, Rosti; Kassem, Wael; Joda, Akram; Büchler, Philippe

    2013-02-01

    Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulations could be improved if either the stress state of the eye under the effect of intraocular pressure is determined, or the stress-free form of the eye estimated prior to conducting the analysis. This study reviews earlier attempts to address this problem and assesses the performance of an iterative technique proposed by Pandolfi and Holzapfel [1], which is both simple to implement and promises high accuracy in estimating the eye's stress-free form. A parametric study has been conducted and demonstrated reliance of the error level on the level of flexibility of the eye model, especially in the cornea region. However, in all cases considered 3-4 analysis iterations were sufficient to produce a stress-free form with average errors in node location <10(-6)mm and a maximal error <10(-4)mm. This error level, which is similar to what has been achieved with other methods and orders of magnitude lower than the accuracy of current clinical topography systems, justifies the use of the technique as a pre-processing step in ocular numerical simulations. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  19. [Studies of vision by Leonardo da Vinci].

    PubMed

    Berggren, L

    2001-01-01

    Leonardo was an advocate of the intromission theory of vision. Light rays from the object to the eye caused visual perceptions which were transported to the brain ventricles via a hollow optic nerve. Leonardo introduced wax injections to explore the ventricular system. Perceptions were assumed to go to the "senso comune" in the middle (3rd) ventricle, also the seat of the soul. The processing station "imprensiva" in the anterior lateral horns together with memory "memoria" in th posterior (4th) ventricle integrated the visual perceptions to visual experience. - Leonardo's sketches with circular lenses in the center of the eye reveal that his dependence on medieval optics prevailed over anatomical observations. Drawings of the anatomy of the sectioned eye are missing although Leonardo had invented a new embedding technique. In order to dissect the eye without spilling its contents, the eye was first boiled in egg white and then cut. The procedure was now repeated and showed that the ovoid lens after boiling had become spherical. - Leonardo described that light rays were refracted and reflected in the eye but his imperfect anatomy prevented a development of physiological optics. He was, however, the first to compare the eye with a pin-hole camera (camera obscura). Leonardo's drawings of the inverted pictures on the back wall of a camera obscura inspired to its use as an instrument for artistic practice. The camera obscura was for centuries a model for explaining human vision.

  20. The Importance of Postural Cues for Determining Eye Height in Immersive Virtual Reality

    PubMed Central

    Leyrer, Markus; Linkenauger, Sally A.; Bülthoff, Heinrich H.; Mohler, Betty J.

    2015-01-01

    In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height. PMID:25993274

  1. The importance of postural cues for determining eye height in immersive virtual reality.

    PubMed

    Leyrer, Markus; Linkenauger, Sally A; Bülthoff, Heinrich H; Mohler, Betty J

    2015-01-01

    In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height.

  2. The utility of modeling word identification from visual input within models of eye movements in reading

    PubMed Central

    Bicknell, Klinton; Levy, Roger

    2012-01-01

    Decades of empirical work have shown that a range of eye movement phenomena in reading are sensitive to the details of the process of word identification. Despite this, major models of eye movement control in reading do not explicitly model word identification from visual input. This paper presents a argument for developing models of eye movements that do include detailed models of word identification. Specifically, we argue that insights into eye movement behavior can be gained by understanding which phenomena naturally arise from an account in which the eyes move for efficient word identification, and that one important use of such models is to test which eye movement phenomena can be understood this way. As an extended case study, we present evidence from an extension of a previous model of eye movement control in reading that does explicitly model word identification from visual input, Mr. Chips (Legge, Klitz, & Tjan, 1997), to test two proposals for the effect of using linguistic context on reading efficiency. PMID:23074362

  3. Monocular tool control, eye dominance, and laterality in New Caledonian crows.

    PubMed

    Martinho, Antone; Burns, Zackory T; von Bayern, Auguste M P; Kacelnik, Alex

    2014-12-15

    Tool use, though rare, is taxonomically widespread, but morphological adaptations for tool use are virtually unknown. We focus on the New Caledonian crow (NCC, Corvus moneduloides), which displays some of the most innovative tool-related behavior among nonhumans. One of their major food sources is larvae extracted from burrows with sticks held diagonally in the bill, oriented with individual, but not species-wide, laterality. Among possible behavioral and anatomical adaptations for tool use, NCCs possess unusually wide binocular visual fields (up to 60°), suggesting that extreme binocular vision may facilitate tool use. Here, we establish that during natural extractions, tool tips can only be viewed by the contralateral eye. Thus, maintaining binocular view of tool tips is unlikely to have selected for wide binocular fields; the selective factor is more likely to have been to allow each eye to see far enough across the midsagittal line to view the tool's tip monocularly. Consequently, we tested the hypothesis that tool side preference follows eye preference and found that eye dominance does predict tool laterality across individuals. This contrasts with humans' species-wide motor laterality and uncorrelated motor-visual laterality, possibly because bill-held tools are viewed monocularly and move in concert with eyes, whereas hand-held tools are visible to both eyes and allow independent combinations of eye preference and handedness. This difference may affect other models of coordination between vision and mechanical control, not necessarily involving tools. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Corneal epithelial wound healing and bactericidal effect of conditioned medium from human uterine cervical stem cells.

    PubMed

    Bermudez, Maria A; Sendon-Lago, Juan; Eiro, Noemi; Treviño, Mercedes; Gonzalez, Francisco; Yebra-Pimentel, Eva; Giraldez, Maria Jesus; Macia, Manuel; Lamelas, Maria Luz; Saa, Jorge; Vizoso, Francisco; Perez-Fernandez, Roman

    2015-01-22

    To evaluate the effect of conditioned medium from human uterine cervical stem cells (CM-hUCESCs) on corneal epithelial healing in a rat model of dry eye after alkaline corneal epithelial ulcer. We also tested the bactericidal effect of CM-hUCESCs. Dry eye was induced in rats by extraocular lacrimal gland excision, and corneal ulcers were produced using NaOH. Corneal histologic evaluation was made with hematoxylin-eosin (H&E) staining. Real-time PCR was used to evaluate mRNA expression levels of proinflammatory cytokines. We also studied the bactericidal effect of CM-hUCESCs in vitro and on infected corneal contact lenses (CLs) using Escherichia coli and Staphylococcus epidermidis bacteria. In addition, in order to investigate proteins from CM-hUCESCs that could mediate these effects, we carried out a human cytokine antibody array. After injury, dry eyes treated with CM-hUCESCs significantly improved epithelial regeneration and showed reduced corneal macrophage inflammatory protein-1 alpha (MIP-1α) and TNF-α mRNA expression as compared to untreated eyes and eyes treated with culture medium or sodium hyaluronate ophthalmic drops. In addition, we found in CM-hUCESCs high levels of proteins, such as tissue inhibitors of metalloproteinases 1 and 2, fibroblast growth factor 6 and 7, urokinase receptor, and hepatocyte growth factor, that could mediate these effects. In vitro, CM-hUCESCs showed a clear bactericidal effect on both E. coli and S. epidermidis and CLs infected with S. epidermidis. Analyses of CM-hUCESCs showed elevated levels of proteins that could be involved in the bactericidal effect, such as the chemokine (C-X-C motif) ligands 1, 6, 8, 10, and the chemokine (C-C motif) ligands 5 and 20. Treatment with CM-hUCESCs improved wound healing of alkali-injured corneas and showed a strong bactericidal effect on CLs. Patients using CLs and suffering from dry eye, allergies induced by commercial solutions, or small corneal injuries could benefit from this treatment. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  5. [Attention and eye movements in human: psychophysiological concepts, neurophysiological models and EEG correlates].

    PubMed

    Slavutskaia, M V; Moiseeva, V V; Shul'govskiĭ, V V

    2008-01-01

    A review. Recently published articles concerning the problem of attention are discussed, the most popular psychophysiological concepts and neurophysiological models of attention are described, and correlation of spatial attention and saccadic eyes movements is shown. The evidence for reflection of attention mechanisms and saccade preparation in intensity and topography of the visual evoked potentials and event-related potentials is given. On the basis of the results obtained by the authors and literature data, the contribution of attention to preparation of a saccade and its programming is shown. Different kinds of attention are reflected in a complex of EEG potentials of various duration and polarity. The analysis of parameters and topography of these potentials can serve a tool for investigation of the attention mechanisms.

  6. Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

    PubMed Central

    Nabili, Marjan; Geist, Craig; Zderic, Vesna

    2015-01-01

    Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm2, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm2 (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone. PMID:26429235

  7. Novel quantitative pigmentation phenotyping enhances genetic association, epistasis, and prediction of human eye colour.

    PubMed

    Wollstein, Andreas; Walsh, Susan; Liu, Fan; Chakravarthy, Usha; Rahu, Mati; Seland, Johan H; Soubrane, Gisèle; Tomazzoli, Laura; Topouzis, Fotis; Vingerling, Johannes R; Vioque, Jesus; Böhringer, Stefan; Fletcher, Astrid E; Kayser, Manfred

    2017-02-27

    Success of genetic association and the prediction of phenotypic traits from DNA are known to depend on the accuracy of phenotype characterization, amongst other parameters. To overcome limitations in the characterization of human iris pigmentation, we introduce a fully automated approach that specifies the areal proportions proposed to represent differing pigmentation types, such as pheomelanin, eumelanin, and non-pigmented areas within the iris. We demonstrate the utility of this approach using high-resolution digital eye imagery and genotype data from 12 selected SNPs from over 3000 European samples of seven populations that are part of the EUREYE study. In comparison to previous quantification approaches, (1) we achieved an overall improvement in eye colour phenotyping, which provides a better separation of manually defined eye colour categories. (2) Single nucleotide polymorphisms (SNPs) known to be involved in human eye colour variation showed stronger associations with our approach. (3) We found new and confirmed previously noted SNP-SNP interactions. (4) We increased SNP-based prediction accuracy of quantitative eye colour. Our findings exemplify that precise quantification using the perceived biological basis of pigmentation leads to enhanced genetic association and prediction of eye colour. We expect our approach to deliver new pigmentation genes when applied to genome-wide association testing.

  8. Novel quantitative pigmentation phenotyping enhances genetic association, epistasis, and prediction of human eye colour

    PubMed Central

    Wollstein, Andreas; Walsh, Susan; Liu, Fan; Chakravarthy, Usha; Rahu, Mati; Seland, Johan H.; Soubrane, Gisèle; Tomazzoli, Laura; Topouzis, Fotis; Vingerling, Johannes R.; Vioque, Jesus; Böhringer, Stefan; Fletcher, Astrid E.; Kayser, Manfred

    2017-01-01

    Success of genetic association and the prediction of phenotypic traits from DNA are known to depend on the accuracy of phenotype characterization, amongst other parameters. To overcome limitations in the characterization of human iris pigmentation, we introduce a fully automated approach that specifies the areal proportions proposed to represent differing pigmentation types, such as pheomelanin, eumelanin, and non-pigmented areas within the iris. We demonstrate the utility of this approach using high-resolution digital eye imagery and genotype data from 12 selected SNPs from over 3000 European samples of seven populations that are part of the EUREYE study. In comparison to previous quantification approaches, (1) we achieved an overall improvement in eye colour phenotyping, which provides a better separation of manually defined eye colour categories. (2) Single nucleotide polymorphisms (SNPs) known to be involved in human eye colour variation showed stronger associations with our approach. (3) We found new and confirmed previously noted SNP-SNP interactions. (4) We increased SNP-based prediction accuracy of quantitative eye colour. Our findings exemplify that precise quantification using the perceived biological basis of pigmentation leads to enhanced genetic association and prediction of eye colour. We expect our approach to deliver new pigmentation genes when applied to genome-wide association testing. PMID:28240252

  9. [Subretinal transplantation of human fetal lung fibroblasts expressed ciliary neurotrophic factor gene prevent photoreceptor degeneration in RCS rats].

    PubMed

    Huang, Qian; Xu, Ping; Xia, Xin; Hu, Hong-hui; Wang, Feng; Li, Hui-ming

    2006-02-01

    To investigate the efficacy of subretinal transplantation of CNTF gene transfected fibroblasts for preventing photoreceptor degeneration in RCS. The human fetal lung fibroblasts with high level expression of CNTF were established by liposome mediated gene transfer and MTX selection. A 5 microl of cell suspension, containing 1 x 10(5) cells, was injected through pars plana of ciliary body into the subretinal space of the right eye at postnatal 4-5 weeks, the left eye was left without injection or injected with PBS as controls. The both eyes were enucleated for histopathological examinations at 2, 4, 6, 8, 10, 12 and 15 weeks following transplantation. The level of CNTF protein (91,046.15 pg/ml) expressed in the transfected cells was determined by sandwich enzyme-linked immunosorbent assay (ELISA). The four of seven eyes examined by light microscopy and the ten of 14 eyes examined by electro microscopy showed rescue effect. The prolonged photoreceptor survival, reduction of apoptotic cells and debris were observed in transplanted eyes in comparison with untreated or sham-injected eyes. This study provides the first indication that transplanted human fibroblasts with high level expression of CNTF are able to rescue photoreceptor degeneration in RCS dystrophic rat retina.

  10. Amylin competes for binding sites of CGRP in the chamber angle and uvea of monkey, cat, and pig eye.

    PubMed

    Alajuuma, Päivi; Oksala, Olli; Uusitalo, Hannu

    2003-12-01

    Calcitonin gene-related peptide (CGRP) binding sites have been identified previously in the eyes of monkey, cat, pig, and guinea pig. In this study, the ability of cat, human, and rat amylins to displace the binding of CGRP in the anterior part of the eye of monkey, cat, and pig was studied. The location and displacement of 125I-hCGRPalpha by amylins as concentrations of 1-1000 nM were studied in cryosections by autoradiography. In the monkey eye, cat and rat amylins were able to compete for the binding sites of CGRP in ciliary muscle and ciliary processes. In the cat eye, cat and human amylins clearly displaced CGRP binding from ciliary muscle, ciliary processes, iris, and chamber angle. Furthermore, rat amylin clearly displaced CGRP binding from ciliary muscle and ciliary processes. In the pig eye, cat, human, and rat amylins competed for the binding sites of CGRP in ciliary muscle, ciliary processes, iris, and limbal conjunctiva. Specific amylin receptors or the possible physiological role of amylin in the eye have not hitherto been reported. It seems, however, that amylin can bind to ocular CGRP receptors and thus probably plays a role in the regulation of the same functions as CGRP, (e.g., aqueous humor outflow).

  11. Restoration of Vision in the pde6β-deficient Dog, a Large Animal Model of Rod-cone Dystrophy

    PubMed Central

    Petit, Lolita; Lhériteau, Elsa; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Provost, Nathalie; Mendes-Madeira, Alexandra; Libeau, Lyse; Guihal, Caroline; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne

    2012-01-01

    Defects in the β subunit of rod cGMP phosphodiesterase 6 (PDE6β) are associated with autosomal recessive retinitis pigmentosa (RP), a childhood blinding disease with early retinal degeneration and vision loss. To date, there is no treatment for this pathology. The aim of this preclinical study was to test recombinant adeno-associated virus (AAV)-mediated gene addition therapy in the rod-cone dysplasia type 1 (rcd1) dog, a large animal model of naturally occurring PDE6β deficiency that strongly resembles the human pathology. A total of eight rcd1 dogs were injected subretinally with AAV2/5RK.cpde6β (n = 4) or AAV2/8RK.cpde6β (n = 4). In vivo and post-mortem morphological analysis showed a significant preservation of the retinal structure in transduced areas of both AAV2/5RK.cpde6β- and AAV2/8RK.cpde6β-treated retinas. Moreover, substantial rod-derived electroretinography (ERG) signals were recorded as soon as 1 month postinjection (35% of normal eyes) and remained stable for at least 18 months (the duration of the study) in treated eyes. Rod-responses were undetectable in untreated contralateral eyes. Most importantly, dim-light vision was restored in all treated rcd1 dogs. These results demonstrate for the first time that gene therapy effectively restores long-term retinal function and vision in a large animal model of autosomal recessive rod-cone dystrophy, and provide great promise for human treatment. PMID:22828504

  12. Restoration of vision in the pde6β-deficient dog, a large animal model of rod-cone dystrophy.

    PubMed

    Petit, Lolita; Lhériteau, Elsa; Weber, Michel; Le Meur, Guylène; Deschamps, Jack-Yves; Provost, Nathalie; Mendes-Madeira, Alexandra; Libeau, Lyse; Guihal, Caroline; Colle, Marie-Anne; Moullier, Philippe; Rolling, Fabienne

    2012-11-01

    Defects in the β subunit of rod cGMP phosphodiesterase 6 (PDE6β) are associated with autosomal recessive retinitis pigmentosa (RP), a childhood blinding disease with early retinal degeneration and vision loss. To date, there is no treatment for this pathology. The aim of this preclinical study was to test recombinant adeno-associated virus (AAV)-mediated gene addition therapy in the rod-cone dysplasia type 1 (rcd1) dog, a large animal model of naturally occurring PDE6β deficiency that strongly resembles the human pathology. A total of eight rcd1 dogs were injected subretinally with AAV2/5RK.cpde6β (n = 4) or AAV2/8RK.cpde6β (n = 4). In vivo and post-mortem morphological analysis showed a significant preservation of the retinal structure in transduced areas of both AAV2/5RK.cpde6β- and AAV2/8RK.cpde6β-treated retinas. Moreover, substantial rod-derived electroretinography (ERG) signals were recorded as soon as 1 month postinjection (35% of normal eyes) and remained stable for at least 18 months (the duration of the study) in treated eyes. Rod-responses were undetectable in untreated contralateral eyes. Most importantly, dim-light vision was restored in all treated rcd1 dogs. These results demonstrate for the first time that gene therapy effectively restores long-term retinal function and vision in a large animal model of autosomal recessive rod-cone dystrophy, and provide great promise for human treatment.

  13. Human Eye Development Is Characterized by Coordinated Expression of Fibrillin Isoforms

    PubMed Central

    Hubmacher, Dirk; Reinhardt, Dieter P.; Plesec, Thomas; Schenke-Layland, Katja; Apte, Suneel S.

    2014-01-01

    Purpose. Mutations in human fibrillin-1 and -2, which are major constituents of tissue microfibrils, can affect multiple ocular components, including the ciliary zonule, lens, drainage apparatus, cornea, and retina. However, the expression pattern of the three human fibrillins and an integral microfibrillar component, MAGP1, during human eye development is not known. Methods. We analyzed sections from human eyes at gestational weeks (GWs) 6, 8, and 11 and at 1 and 3 years of age with antibodies specific for each human fibrillin isoform or MAGP1, using immunofluorescence microscopy. Results. During embryonic development, each fibrillin isoform was detected in vascular structures bridging the ciliary body and the developing lens, hyaloid vasculature, and retina. In addition, they were present in the developing corneal basement membranes and lens capsule. MAGP1 codistributed with the fibrillin isoforms. In contrast, the juvenile zonule was composed of fibrillin-1 microfibrils containing MAGP1, but fibrillin-2 was absent and fibrillin-3 was only sparsely detected. Conclusions. Fibrillin-1, -2, and, unique to humans, fibrillin-3 are found in various ocular structures during human embryonic eye development, whereas fibrillin-1 dominates the postnatal zonule. We speculate that vasculature spanning the ciliary body and lens, which elaborates fibrillin-2 and -3, may provide an initial scaffold for fibrillin assembly and zonule formation. PMID:25406291

  14. Tutorial on Biostatistics: Linear Regression Analysis of Continuous Correlated Eye Data

    PubMed Central

    Ying, Gui-shuang; Maguire, Maureen G; Glynn, Robert; Rosner, Bernard

    2017-01-01

    Purpose To describe and demonstrate appropriate linear regression methods for analyzing correlated continuous eye data. Methods We describe several approaches to regression analysis involving both eyes, including mixed effects and marginal models under various covariance structures to account for inter-eye correlation. We demonstrate, with SAS statistical software, applications in a study comparing baseline refractive error between one eye with choroidal neovascularization (CNV) and the unaffected fellow eye, and in a study determining factors associated with visual field data in the elderly. Results When refractive error from both eyes were analyzed with standard linear regression without accounting for inter-eye correlation (adjusting for demographic and ocular covariates), the difference between eyes with CNV and fellow eyes was 0.15 diopters (D; 95% confidence interval, CI −0.03 to 0.32D, P=0.10). Using a mixed effects model or a marginal model, the estimated difference was the same but with narrower 95% CI (0.01 to 0.28D, P=0.03). Standard regression for visual field data from both eyes provided biased estimates of standard error (generally underestimated) and smaller P-values, while analysis of the worse eye provided larger P-values than mixed effects models and marginal models. Conclusion In research involving both eyes, ignoring inter-eye correlation can lead to invalid inferences. Analysis using only right or left eyes is valid, but decreases power. Worse-eye analysis can provide less power and biased estimates of effect. Mixed effects or marginal models using the eye as the unit of analysis should be used to appropriately account for inter-eye correlation and maximize power and precision. PMID:28102741

  15. Assessment of Thermal Dehydration Using the Human Eye: What is the Potential?

    DTIC Science & Technology

    2012-01-01

    Kenefick a, Neil P. Walsh b, Matthew B. Fortes b, Marieh Esmaeelpour c,d, Samuel N. Cheuvront a,n a US Army Research Institute of Environmental Medicine...anhydrase inhibitors, which are commonly prescribed to glaucoma patients (van der Valk et al., 2005; World Heath Organization; 2009). Both types of...Deposition and thinning of the human tear film. J. Colloid Interface Sci. 184, 44–51. World Heath Organization, 2009. WHO model formulary 2008. WHO

  16. The 14th Annual Conference on Manual Control. [digital simulation of human operator dynamics

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Human operator dynamics during actual manual control or while monitoring the automatic control systems involved in air-to-air tracking, automobile driving, the operator of undersea vehicles, and remote handling are examined. Optimal control models and the use of mathematical theory in representing man behavior in complex man machine system tasks are discussed with emphasis on eye/head tracking and scanning; perception and attention allocation; decision making; and motion simulation and effects.

  17. Mucin deficiency causes functional and structural changes of the ocular surface.

    PubMed

    Floyd, Anne M; Zhou, Xu; Evans, Christopher; Rompala, Olivia J; Zhu, Lingxiang; Wang, Mingwu; Chen, Yin

    2012-01-01

    MUC5AC is the most abundant gel-forming mucin in the ocular system. However, the specific function is unknown. In the present study, a Muc5ac knockout (KO) mouse model was subject to various physiological measurements as compared to its wide-type (WT) control. Interestingly, when KO mice were compared to WT mice, the mean tear break up time (TBUT) values were significantly lower and corneal fluorescein staining scores were significantly higher. But the tear volume was not changed. Despite the lack of Muc5ac expression in the conjunctiva of KO mice, Muc5b expression was significantly increased in these mice. Corneal opacification, varying in location and severity, was found in a few KO mice but not in WT mice. The present results suggest a significant difference in the quality, but not the quantity, of tear fluid in the KO mice compared to WT mice. Dry eye disease is multifactorial and therefore further evaluation of the varying components of the tear film, lacrimal unit and corneal structure of these KO mice may help elucidate the role of mucins in dry eye disease. Because Muc5ac knockout mice have clinical features of dry eye, this mouse model will be extremely useful for further studies regarding the pathophysiology of the ocular surface in dry eye in humans.

  18. Ocular Nerve Growth Factor (NGF) and NGF Eye Drop Application as Paradigms to Investigate NGF Neuroprotective and Reparative Actions.

    PubMed

    Tirassa, Paola; Rosso, Pamela; Iannitelli, Angela

    2018-01-01

    The eye is a central nervous system structure that is uniquely accessible to local treatment. Through the ocular surface, it is possible to access the retina, optic nerve, and brain. Animal models of retina degeneration or optic nerve crush could thus serve as tools to investigate whether and how factors, which are anterogradely or retrogradely transported through the optic nerve, might contribute to activate neuroprotection and eventually regeneration. Among these factors, nerve growth factor (NGF) plays a crucial role during development of the visual system, as well as during the entire life span, and in pathological conditions. The ability of NGF to exert survival and trophic actions on the retina and brain cells when applied intraocularly and topically as eye drops is critically reviewed here, together with the effects of ocular neurotrophins on neuronal pathways influencing body rhythm, cognitions, and behavioral functions. The latest data from animal models and humans are presented, and the mechanism of action of ocularly administered NGF is discussed. NGF eye drops are proposed as an experimental strategy to investigate the role and cellular targets of neurotrophins in the mechanism(s) underlying neurodegeneration/regeneration and their involvement in the regulation of neurological and behavioral dysfunctions.

  19. Gaze-contingent control for minimally invasive robotic surgery.

    PubMed

    Mylonas, George P; Darzi, Ara; Yang, Guang Zhong

    2006-09-01

    Recovering tissue depth and deformation during robotically assisted minimally invasive procedures is an important step towards motion compensation, stabilization and co-registration with preoperative data. This work demonstrates that eye gaze derived from binocular eye tracking can be effectively used to recover 3D motion and deformation of the soft tissue. A binocular eye-tracking device was integrated into the stereoscopic surgical console. After calibration, the 3D fixation point of the participating subjects could be accurately resolved in real time. A CT-scanned phantom heart model was used to demonstrate the accuracy of gaze-contingent depth extraction and motion stabilization of the soft tissue. The dynamic response of the oculomotor system was assessed with the proposed framework by using autoregressive modeling techniques. In vivo data were also used to perform gaze-contingent decoupling of cardiac and respiratory motion. Depth reconstruction, deformation tracking, and motion stabilization of the soft tissue were possible with binocular eye tracking. The dynamic response of the oculomotor system was able to cope with frequencies likely to occur under most routine minimally invasive surgical operations. The proposed framework presents a novel approach towards the tight integration of a human and a surgical robot where interaction in response to sensing is required to be under the control of the operating surgeon.

  20. Characterization of pulse amplitude and pulse rate modulation for a human vestibular implant during acute electrical stimulation

    NASA Astrophysics Data System (ADS)

    Nguyen, T. A. K.; DiGiovanna, J.; Cavuscens, S.; Ranieri, M.; Guinand, N.; van de Berg, R.; Carpaneto, J.; Kingma, H.; Guyot, J.-P.; Micera, S.; Perez Fornos, A.

    2016-08-01

    Objective. The vestibular system provides essential information about balance and spatial orientation via the brain to other sensory and motor systems. Bilateral vestibular loss significantly reduces quality of life, but vestibular implants (VIs) have demonstrated potential to restore lost function. However, optimal electrical stimulation strategies have not yet been identified in patients. In this study, we compared the two most common strategies, pulse amplitude modulation (PAM) and pulse rate modulation (PRM), in patients. Approach. Four subjects with a modified cochlear implant including electrodes targeting the peripheral vestibular nerve branches were tested. Charge-equivalent PAM and PRM were applied after adaptation to baseline stimulation. Vestibulo-ocular reflex eye movement responses were recorded to evaluate stimulation efficacy during acute clinical testing sessions. Main results. PAM evoked larger amplitude eye movement responses than PRM. Eye movement response axes for lateral canal stimulation were marginally better aligned with PRM than with PAM. A neural network model was developed for the tested stimulation strategies to provide insights on possible neural mechanisms. This model suggested that PAM would consistently cause a larger ensemble firing rate of neurons and thus larger responses than PRM. Significance. Due to the larger magnitude of eye movement responses, our findings strongly suggest PAM as the preferred strategy for initial VI modulation.

  1. Effects of phencyclidine, secobarbital and diazepam on eye tracking in rhesus monkeys.

    PubMed

    Ando, K; Johanson, C E; Levy, D L; Yasillo, N J; Holzman, P S; Schuster, C R

    1983-01-01

    Rhesus monkeys were trained to track a moving disk using a procedure in which responses on a lever were reinforced with water delivery only when the disk, oscillating in a horizontal plane on a screen at a frequency of 0.4 Hz in a visual angle of 20 degrees, dimmed for a brief period. Pursuit eye movements were recorded by electrooculography (EOG). IM phencyclidine, secobarbital, and diazepam injections decreased the number of reinforced lever presses in a dose-related manner. Both secobarbital and diazepam produced episodic jerky-pursuit eye movements, while phencyclidine had no consistent effects on eye movements. Lever pressing was disrupted at doses which had little effect on the quality of smooth-pursuit eye movements in some monkeys. This separation was particularly pronounced with diazepam. The similarities of the drug effects on smooth-pursuit eye movements between the present study and human studies indicate that the present method using rhesus monkeys may be useful for predicting drug effects on eye tracking and oculomotor function in humans.

  2. Simulation of Ametropic Human Eyes

    NASA Astrophysics Data System (ADS)

    Tan, Bo; Chen, Ying-Ling; Lewis, James W. L.

    2004-11-01

    The computational simulation of the performance of human eyes is complex because the optical parameters of the eye depend on many factors, including age, gender, race, refractive status (accommodation and near- or far-sightedness). This task is made more difficult by the inadequacy of the population statistical characteristics of these parameters. Previously we simulated ametropic (near- or far-sighted) eyes using three independent variables: the axial length of the eye, the corneal surface curvature, and the intraocular refractive index gradient. The prescription for the correction of an ametropic eye is determined by its second-order coefficients of the wavefront aberrations. These corrections are typically achieved using contact lens, spectacle lens, or laser surgery (LASIK). However, the higher order aberrations, which are not corrected and are likely complicated or enhanced by the lower-order correction, could be important for visual performance in a darkened environment. In this paper, we investigate the higher order wavefront aberrations of synthetic ametropic eyes and compare results with measured data published in the past decade. The behavior of three types of ametropes is discussed.

  3. Fundus autofluorescence and fate of glycoxidized particles injected into subretinal space in rabbit age-related macular degeneration model.

    PubMed

    Hirata, Megumi; Yasukawa, Tsutomu; Wiedemann, Peter; Kimura, Erika; Kunou, Noriyuki; Eichler, Wolfram; Takase, Ayae; Sato, Rina; Ogura, Yuichiro

    2009-07-01

    Abnormal fundus autofluorescence (FAF) is associated with the incidence or progression of dry and wet age-related macular degeneration (AMD). We previously developed a rabbit AMD model with drusen and type-1 choroidal neovascularization (CNV) that mimics the accumulation of lipofuscin using artificial glycoxidized particles. The objective of the current study was to investigate in vitro effects of glycoxidized particles on retinal pigment epithelial (RPE) cells, and the FAF and fate of injected particles in this model. Glycoxidized particles were prepared by a 4-day incubation of water-in-oil emulsions of serum albumin and glycolaldehyde to allow glycoxidation and consequent cross-linking. After particles were added in the culture medium of confluent human RPE cells, cell viability, adhesion activity, and proliferation activity were assessed by cell counting. In anesthetized rabbits, 250 microg of glycoxidized particles were injected into the subretinal space to induce experimental AMD. FAF measurement and angiography with sodium fluorescein and indocyanine green were performed periodically using the Heidelberg Retina Angiograph 2 (HRA2). The eyes enucleated, and the lung and the spleen, excised at week 4 or 12, were histologically evaluated by light and fluorescence microscopy. Glycoxidized particles phagocytosed did not impair the cell viability, adhesion, and proliferation of RPE cells, as compared with RPE cells in controls. HRA2 showed different patterns of abnormal FAF in the area with the implanted glycoxidized particles, similar to pathological FAF patterns in aging human eyes with or without AMD. Histologic examination showed accumulated glycoxidized particles and large lipofuscin granules with green autofluorescence in and under the RPE and at the margins of or beneath drusen, possibly associated with abnormal FAF. In addition, some particles were detected in the lung and the spleen. Glycoxidized particles phagocytosed might stay in RPE cells without any acute biological reaction. Our rabbit model of AMD simulated abnormal FAF patterns observed in aging human eyes with or without AMD. Glycoxidized particles phagocytosed by RPE cells could be deposited on Bruch's membrane in rabbits, possibly excreted in part into choroidal circulation. This model may be useful for understanding various patterns of abnormal FAF histologically, and for elucidating the pathogenesis of AMD.

  4. 40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following information: WARNING: CONTACT WITH SKIN AND EYES IS HARMFUL —Severe skin and eye irritant.... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing... water. FIRST AID: —In case of eye contact, immediately flush with plenty of water and get immediate...

  5. 76 FR 24499 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: June 16, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...

  6. 78 FR 73867 - National Eye Institute; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of a meeting of the National Advisory Eye Council. The meeting will be... Advisory Eye Council. Date: January 23, 2014. Open: 8:30 a.m. to 2:00 p.m. Agenda: Following opening...

  7. 75 FR 54642 - National Eye Institute; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to the...: National Advisory Eye Council. Date: October 21, 2010. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...

  8. 76 FR 53687 - National Eye Institute Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: October 13, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...

  9. 77 FR 2076 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: February 2, 2012. Open: 8 a.m. to 12 p.m. Agenda: Following opening...

  10. 77 FR 31032 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-24

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: June 14, 2012. Open: 8:00 a.m. to 3:00 p.m. Agenda: Following opening...

  11. 40 CFR 156.70 - Precautionary statements for human hazards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...

  12. 40 CFR 156.70 - Precautionary statements for human hazards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., dermal, inhalation toxicity) Irritation effects (skin and eye) Sensitizer (There are no categories of... or spray mist]. Do not get in eyes, on skin, or on clothing. [Front panel first aid statement required.] Corrosive, causes eye and skin damage [or skin irritation]. Do not get in eyes on skin, or on...

  13. 77 FR 55852 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: October 4, 2012. Open: 8:30 a.m. to 2 p.m. Agenda: Following opening...

  14. 75 FR 26260 - National Eye Institute; Amended Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute; Amended Notice of Meeting Notice is hereby given of a change in the meeting of the National Eye Institute Special Emphasis Panel, April 20, 2010, 3 p.m., to April 20, 2010, 4 p.m., National Eye Institute, 5635...

  15. 75 FR 76474 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), notice is hereby given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: January 20, 2011. Open: 8:30 a.m. to 12 p.m. Agenda: Following opening...

  16. 77 FR 41406 - Evaluation of In Vitro Tests for Identifying Eye Injury Hazard Potential of Chemicals and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Evaluation of In Vitro Tests for Identifying Eye Injury...-animal testing strategies proposed for identifying eye injury hazard potential of chemicals and products... Panel and submission of data from substances tested in in vitro tests for identifying eye injury hazard...

  17. 77 FR 73037 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute....S.C. App.), Notice is Hereby Given of the National Advisory Eye Council. The meeting will be open to...: National Advisory Eye Council. Date: January 10, 2013. Open: 8:30 a.m. to 2:00 p.m. Agenda: Following...

  18. 75 FR 11551 - National Eye Institute; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute.... App.), notice is hereby given of a meeting of the National Advisory Eye Council. The meeting will be...: National Advisory Eye Council. Date: June 17, 2010. Closed: 8:30 a.m. to 11 a.m. Agenda: To review and...

  19. Eye Movements During Everyday Behavior Predict Personality Traits.

    PubMed

    Hoppe, Sabrina; Loetscher, Tobias; Morey, Stephanie A; Bulling, Andreas

    2018-01-01

    Besides allowing us to perceive our surroundings, eye movements are also a window into our mind and a rich source of information on who we are, how we feel, and what we do. Here we show that eye movements during an everyday task predict aspects of our personality. We tracked eye movements of 42 participants while they ran an errand on a university campus and subsequently assessed their personality traits using well-established questionnaires. Using a state-of-the-art machine learning method and a rich set of features encoding different eye movement characteristics, we were able to reliably predict four of the Big Five personality traits (neuroticism, extraversion, agreeableness, conscientiousness) as well as perceptual curiosity only from eye movements. Further analysis revealed new relations between previously neglected eye movement characteristics and personality. Our findings demonstrate a considerable influence of personality on everyday eye movement control, thereby complementing earlier studies in laboratory settings. Improving automatic recognition and interpretation of human social signals is an important endeavor, enabling innovative design of human-computer systems capable of sensing spontaneous natural user behavior to facilitate efficient interaction and personalization.

  20. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

Top