Sample records for human plasma relation

  1. Novel Parvovirus and Related Variant in Human Plasma

    PubMed Central

    Fryer, Jacqueline F.; Kapoor, Amit; Minor, Philip D.; Delwart, Eric

    2006-01-01

    We report a novel parvovirus (PARV4) and related variants in pooled human plasma used in the manufacture of plasma-derived medical products. Viral DNA was detected by using highly selective polymerase chain reaction assays; 5% of pools tested positive, and amounts of DNA ranged from <500 copies/mL to >106 copies/mL plasma. PMID:16494735

  2. The State of the Human Proteome in 2013 as viewed through PeptideAtlas: Comparing the Kidney, Urine, and Plasma Proteomes for the Biology and Disease-driven Human Proteome Project

    PubMed Central

    Farrah, Terry; Deutsch, Eric W.; Omenn, Gilbert S.; Sun, Zhi; Watts, Julian D.; Yamamoto, Tadashi; Shteynberg, David; Harris, Micheleen M.; Moritz, Robert L.

    2014-01-01

    The kidney, urine, and plasma proteomes are intimately related: proteins and metabolic waste products are filtered from the plasma by the kidney and excreted via the urine, while kidney proteins may be secreted into the circulation or released into the urine. Shotgun proteomics datasets derived from human kidney, urine, and plasma samples were collated and processed using a uniform software pipeline, and relative protein abundances were estimated by spectral counting. The resulting PeptideAtlas builds yielded 4005, 2491, and 3553 nonredundant proteins at 1% FDR for the kidney, urine, and plasma proteomes, respectively—for kidney and plasma, the largest high-confidence protein sets to date. The same pipeline applied to all available human data yielded a 2013 Human PeptideAtlas build containing 12,644 nonredundant proteins and at least one peptide for each of ~14,000 Swiss-Prot entries, an increase over 2012 of ~7.5% of the predicted human proteome. We demonstrate that abundances are correlated between plasma and urine, examine the most abundant urine proteins not derived from either plasma or kidney, and consider the biomarker potential of proteins associated with renal decline. This analysis forms part of the Biology and Disease-driven Human Proteome Project (B/D-HPP) and a contribution to the Chromosome-centric Human Proteome Project (C-HPP) special issue. PMID:24261998

  3. Analysis of human blood plasma cell-free DNA fragment size distribution using EvaGreen chemistry based droplet digital PCR assays.

    PubMed

    Fernando, M Rohan; Jiang, Chao; Krzyzanowski, Gary D; Ryan, Wayne L

    2018-04-12

    Plasma cell-free DNA (cfDNA) fragment size distribution provides important information required for diagnostic assay development. We have developed and optimized droplet digital PCR (ddPCR) assays that quantify short and long DNA fragments. These assays were used to analyze plasma cfDNA fragment size distribution in human blood. Assays were designed to amplify 76,135, 490 and 905 base pair fragments of human β-actin gene. These assays were used for fragment size analysis of plasma cell-free, exosome and apoptotic body DNA obtained from normal and pregnant donors. The relative percentages for 76, 135, 490 and 905 bp fragments from non-pregnant plasma and exosome DNA were 100%, 39%, 18%, 5.6% and 100%, 40%, 18%,3.3%, respectively. The relative percentages for pregnant plasma and exosome DNA were 100%, 34%, 14%, 23%, and 100%, 30%, 12%, 18%, respectively. The relative percentages for non-pregnant plasma pellet (obtained after 2nd centrifugation step) were 100%, 100%, 87% and 83%, respectively. Non-pregnant Plasma cell-free and exosome DNA share a unique fragment distribution pattern which is different from pregnant donor plasma and exosome DNA fragment distribution indicating the effect of physiological status on cfDNA fragment size distribution. Fragment distribution pattern for plasma pellet that includes apoptotic bodies and nuclear DNA was greatly different from plasma cell-free and exosome DNA. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Selective enrichment of n-3 fatty acids in human plasma lipid motifs following intake of marine fish

    USDA-ARS?s Scientific Manuscript database

    Plasma levels of n-3 long chain polyunsaturated fatty acids (LCPUFA) are associated with a reduction in risk of cardiovascular disease and other chronic, age-related diseases like Alzheimer’s disease. In this work, we tested the hypothesis that n-3 LCPUFA fatty acids in human plasma are incorporated...

  5. Independent effects of apolipoprotein AV and apolipoprotein CIII on plasma triglyceride concentrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baroukh, Nadine N.; Bauge, Eric; Akiyama, Jennifer

    2003-08-15

    Both the apolipoprotein A5 and C3 genes have repeatedly been shown to play an important role in determining plasma triglyceride concentrations in humans and mice. In mice, transgenic and knockout experiments indicate that plasma triglyceride levels are negatively and positively correlated with APOA5 and APOC3 expression, respectively. In humans, common polymorphisms in both genes have also been associated with plasma triglyceride concentrations. The evolutionary relationship among these two apolipoprotein genes and their close proximity on human chromosome 11q23 have largely precluded the determination of their relative contribution to altered Both the apolipoprotein A5 and C3 genes have repeatedly been shownmore » to play an important role in determining plasma triglyceride concentrations in humans and mice. In mice, transgenic and knockout experiments indicate that plasma triglyceride levels are negatively and positively correlated with APOA5 and APOC3 expression, respectively. In humans, common polymorphisms in both genes have also been associated with plasma triglyceride concentrations. The evolutionary relationship among these two apolipoprotein genes and their close proximity on human chromosome 11q23 have largely precluded the determination of their relative contribution to altered triglycerides. To overcome these confounding factors and address their relationship, we generated independent lines of mice that either over-expressed (''double transgenic'') or completely lacked (''double knockout'') both apolipoprotein genes. We report that both ''double transgenic'' and ''double knockout'' mice display intermedia tetriglyceride concentrations compared to over-expression or deletion of either gene alone. Furthermore, we find that human ApoAV plasma protein levels in the ''double transgenic'' mice are approximately 500-fold lower than human ApoCIII levels, supporting ApoAV is a potent triglyceride modulator despite its low concentration. Together, these data indicate that APOA5 and APOC3 independently influence plasma triglyceride concentrations but in an opposing manner.« less

  6. Plasma protein hydroperoxides during aging in humans: correlation with paraoxonase 1 (PON1) arylesterase activity and plasma total thiols.

    PubMed

    Mehdi, Mohammad Murtaza; Rizvi, Syed Ibrahim

    2013-02-01

    Oxidative stress is thought to play a major role in the development of several age-dependent diseases. Proteins are major targets for oxidative attack. Protein hydroperoxides are formed by hydroxyl and singlet oxygen attack on protein, forming relatively stable hydroperoxides on histidine, tyrosine and tryptophan residues. This study investigated the levels of plasma protein hydroperoxides and antioxidant potential of plasma during aging in humans. We correlated the protein hydroperoxide formation with plasma antioxidant potential, paraoxonase 1 (PON1) arylesterase activity and plasma total thiols. The protein hydroperoxides and antioxidant potential were measured in plasma of human subjects aged between 20 and 81 years of both genders. Increase in plasma protein hydroperoxides and decrease in plasma antioxidant potential were observed as function of human age. This study provides strong correlation between plasma protein hydroperoxides formation and decrease in plasma antioxidant potential during aging. PON1 arylesterase activity and plasma total thiols levels were also found to show significant correlation with increasing levels of plasma protein hydroperoxides during aging. The plasma protein hydroperoxides provide a reliable marker of long-term redox balance and degree of oxidative stress during aging process. Copyright © 2013 IMSS. Published by Elsevier Inc. All rights reserved.

  7. Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma.

    PubMed

    Ahmadi-Jouibari, Toraj; Fattahi, Nazir; Shamsipur, Mojtaba; Pirsaheb, Meghdad

    2013-11-01

    A novel, simple, rapid and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine opium alkaloids in human plasma. During the extraction procedure, plasma protein was precipitated by using a mixture of zinc sulfate solution and acetonitrile. Some effective parameters on extraction were studied and optimized. Under the optimum conditions (extraction solvent: 30.0 μl 1-undecanol; disperser solvent: 470 μl acetone; pH: 9; salt addition: 1%(w/v) NaCl and extraction time: 0.5 min), calibration curves are linear in the range of 1.5-1000 μgl(-1) and limit of detections (LODs) are in the range of 0.5-5 μgl(-1). The relative standard deviations (RSDs) for 100 μgl(-1) of morphine and codeine, 10.0 μgl(-1) of papaverine and 20.0 μgl(-1) of noscapine in diluted human plasma are in the range of 4.3-7.4% (n=5). Finally, the method was successfully applied in the determination of opium alkaloids in the actual human plasma samples. The relative recoveries of plasma samples spiked with alkaloids are 88-110.5%. The obtained results show that DLLME-SFO combined with HPLC-UV is a fast and simple method for the determination of opium alkaloids in human plasma. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Bioavailability of astaxanthin stereoisomers from wild (Oncorhynchus spp.) and aquacultured (Salmo salar) salmon in healthy men: a randomised, double-blind study.

    PubMed

    Rüfer, Corinna E; Moeseneder, Jutta; Briviba, Karlis; Rechkemmer, Gerhard; Bub, Achim

    2008-05-01

    The objective of the present study was to investigate the bioavailability and the configurational isomer distribution of the carotenoid astaxanthin (AST) in human plasma after ingestion of wild (Oncorhynchus spp.) and aquacultured (Salmo salar) salmon. In a randomised and double-blind trial, twenty-eight healthy men consumed 250 g wild or aquacultured salmon daily for 4 weeks which provided 5 mug AST/g salmon flesh. The plasma AST concentrations as well as the isomer distribution were measured by HPLC using a reversed and a chiral stationary phase. After 6 d of intervention with salmon, plasma AST concentrations reached a plateau of 39 nmol/l after consumption of wild salmon and of 52 nmol/l after administration of aquacultured salmon. At days 3, 6, 10 and 14 -- but not at day 28 -- the AST concentrations in human plasma were significantly greater after ingestion of aquacultured salmon. After administration of wild salmon, the (3S,3'S) isomer predominated in plasma (80 %), whereas after intake of aquacultured salmon the meso form (3R,3'S) prevailed (48 %). Therefore, the AST isomer pattern in human plasma resembles that of the ingested salmon. However, after consumption of both wild and aquacultured salmon for 28 d the relative proportion of the (3S,3'S) isomer was slightly higher and the (3R,3'R) form lower in human plasma compared with the isomer distribution in salmon flesh. A selective process of isomer absorption could be responsible for the observed differences in the relative proportions of the (3S,3'S) and (3R,3'R) isomers in human plasma compared with salmon flesh.

  9. Leptin is present in human milk and is related to maternal plasma leptin concentration and adiposity.

    PubMed

    Houseknecht, K L; McGuire, M K; Portocarrero, C P; McGuire, M A; Beerman, K

    1997-11-26

    Leptin is elevated during pregnancy and may be involved in the regulation of milk production in women. Immunoreactive leptin was quantified in human milk by modified radioimmunoassay. Leptin concentration was higher in whole vs. skim milk fractions; however, leptin concentration was not correlated with percentage milk fat. Leptin concentrations in whole and skim milk were correlated with maternal plasma leptin concentrations, maternal body weight, body mass index, and tricep skinfold thickness, but not with plasma insulin concentration. These data provide the first evidence for the presence of leptin in human milk in the range of concentrations found in human plasma and indicate that the concentration of leptin in milk reflects maternal adiposity. Determining the biological role(s) of milk-borne leptin could add to our understanding of neonatal metabolism and the mechanisms underlying the development of body fat and obesity in humans.

  10. Measurement of Ether Phospholipids in Human Plasma with HPLC-ELSD and LC/ESI-MS After Hydrolysis of Plasma with Phospholipase A1.

    PubMed

    Mawatari, Shiro; Hazeyama, Seira; Fujino, Takehiko

    2016-08-01

    Ethanolamine ether phospholipid (eEtnGpl) and choline ether phospholipid (eChoGpl) are present in human plasma or serum, but the relative concentration of the ether phospholipids in plasma is very low as compared to those in other tissues. Nowadays, measurement of ether phospholipids in plasma depends on tandem mass spectrometry (LC/MS/MS), but a system for LC/MS/MS is generally too expensive for usual clinical laboratories. Treatment of plasma with phospholipase A1 (PLA1) causes complete hydrolysis of diacylphospholipids, but ether phospholipids remain intact. After the treatment of plasma with PLA1, both eEtnGpl and eChoGpl are detected as independent peaks by high-performance liquid chromatography with evaporative light scattering detection (HPLC-ELSD). The same sample used for HPLC-ELSD can be applied to detect eEtnGpl and eChoGpl with electrospray ionization mass spectrometry. Presence of alkylacylphospholipids in both eChoGpl and eEtnGpl in human plasma was indicated by sequential hydrolysis of plasma with PLA1 and hydrochloric acid.

  11. Susceptibility of Mice to Trypanosoma evansi Treated with Human Plasma Containing Different Concentrations of Apolipoprotein L-1

    PubMed Central

    Fanfa, Vinicius R.; Otto, Mateus A.; Gressler, Lucas T.; Tavares, Kaio C.S.; Lazzarotto, Cícera R.; Tonin, Alexandre A.; Miletti, Luiz C.; Duarte, Marta M.M.F.; Monteiro, Silvia G.

    2011-01-01

    The aim of this study was to test the susceptibility of mice to Trypanosoma evansi treated with human plasma containing different concentrations of apolipoprotein L-1 (APOL1). For this experiment, a strain of T. evansi and human plasma (plasmas 1, 2, and 3) from 3 adult males clinically healthy were used. In vivo test used 50 mice divided in 5 groups (A to E) with 10 animals in each group. Animals of groups B to E were infected, and then treated with 0.2 ml of human plasma in the following outline: negative control (A), positive control (B), treatment with plasma 1 (C), treatment with plasma 2 (D), and treatment with plasma 3 (E). Mice treated with human plasma showed an increase in longevity of 40.9±0.3 (C), 20±9.0 (D) and 35.6±9.3 (E) days compared to the control group (B) which was 4.3±0.5 days. The number of surviving mice and free of the parasite (blood smear and PCR negative) at the end of the experiment was 90%, 0%, and 60% for groups C, D, and E, respectively. The quantification of APOL1 was performed due to the large difference in the treatments that differed in the source plasma. In plasmas 1, 2, and 3 was detected the concentration of 194, 99, and 115 mg/dl of APOL1, respectively. However, we believe that this difference in the treatment efficiency is related to the level of APOL1 in plasmas. PMID:22355213

  12. Effects of itopride hydrochloride on plasma gut-regulatory peptide and stress-related hormone levels in healthy human subjects.

    PubMed

    Katagiri, Fumihiko; Shiga, Toru; Inoue, Shin; Sato, Yuhki; Itoh, Hiroki; Takeyama, Masaharu

    2006-01-01

    Itopride hydrochloride (itopride), a gastrokinetic drug, has recently been evaluated for its clinical usefulness in functional dyspepsia. We investigated effects of itopride on human plasma gastrin-, somatostatin-, motilin-, and cholecystokinin (CCK)-like immunoreactive substances (IS); adrenocorticotropic hormone (ACTH)-immunoreactive substances (IS), and cortisol under stress conditions in healthy subjects. A single administration of itopride caused significant increases in plasma somatostatin- and motilin-IS levels compared to placebo. Itopride significantly decreased plasma CCK-IS, and suppressed the ACTH-IS level compared to placebo. We hypothesize that itopride may have an accelerating gastric emptying effect, and a modulatory effect on the hypothalamo-pituitary-adrenal axis and autonomic nervous functions. These effects might be beneficial in stress-related diseases, suggesting that itopride has clinicopharmacological activities.

  13. Determination of flurbiprofen in human plasma by gas chromatography with mass spectrometry and its pharmacokinetics.

    PubMed

    Yilmaz, Bilal; Sahin, Huseyin; Akba, Vedat; Erdem, Ali Fuat

    2014-01-01

    This paper describes a GCIMS method for the determination of flurbiprofen in human plasma. Flurbiprofen and internal standard ibuprofen were extracted from plasma by using a liquid-liquid extraction method. Derivatization was carried out using N-Methyl-N-(trimethylsilyl)trifluoroacetamide. The calibration curve was linear between the concentration range of 0.10 and 5.0 microg/mL. Intraday and interday precision values for flurbiprofen in plasma were less than 5.49%, and accuracy (relative error) was better than 5.33%. The extraction recoveries of flurbiprofen from human plasma were between 93.6 and 98.6%. The LOD and LOQ of flurbiprofen were 0.03 and 0.10 microg/mL, respectively. This assay was applied to determine the pharmacokinetic parameters of flurbiprofen in healthy Turkish volunteers who had been given 100 mg of flurbiprofen.

  14. Microwave digestion preparation and ICP determination of boron in human plasma

    NASA Technical Reports Server (NTRS)

    Ferrando, A. A.; Green, N. R.; Barnes, K. W.; Woodward, B.

    1993-01-01

    A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

  15. Designing plasmas for chronic wound disinfection

    NASA Astrophysics Data System (ADS)

    Nosenko, T.; Shimizu, T.; Morfill, G. E.

    2009-11-01

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  16. Plasma choline and betaine and their relation to plasma homocysteine in normal pregnancy.

    PubMed

    Velzing-Aarts, Francien V; Holm, Pål I; Fokkema, M Rebecca; van der Dijs, Fey P; Ueland, Per M; Muskiet, Frits A

    2005-06-01

    Plasma concentrations of total homocysteine (tHcy) decrease during pregnancy. This reduction has been investigated in relation to folate status, but no study has addressed the possible role of betaine and its precursor choline. We investigated the courses of plasma choline and betaine during normal human pregnancy and their relations to plasma tHcy. Blood samples were obtained monthly; the initial samples were taken at gestational week (GW) 9, and the last samples were taken approximately 3 mo postpartum. The study population comprised 50 women of West African descent. Most of the subjects took folic acid irregularly. Plasma choline (geometric x; 95% reference interval) increased continuously during pregnancy, from 6.6 (4.5, 9.7) micromol/L at GW 9 to 10.8 (7.4, 15.6) micromol/L at GW 36. Plasma betaine decreased in the first half of pregnancy, from 16.3 (8.6, 30.8) micromol/L at GW 9 to 10.3 (6.6, 16.2) micromol/L at GW 20 and remained constant thereafter. We confirmed a reduction in plasma tHcy, and the lowest concentration was found in the second trimester. From GW 16 onward, an inverse relation between plasma tHcy and betaine was observed. Multiple regression analysis showed that plasma betaine was a strong predictor of plasma tHcy from GW 20 onward. The steady increase in choline throughout gestation may ensure choline availability for placental transfer with subsequent use by the growing fetus. Betaine becomes a strong predictor of tHcy during the course of pregnancy. Both of these findings emphasize the importance of choline and betaine status during normal human pregnancy.

  17. Pre-formulation studies of resveratrol

    PubMed Central

    Robinson, Keila; Mock, Charlotta; Liang, Dong

    2015-01-01

    Context Resveratrol, a natural compound found in grapes, has potential chemotherapy effects but very low oral bioavailability in humans. Objective To evaluate the solubility, pH stability profile, plasma protein binding (PPB) and stability in plasma for resveratrol. Methods Solubility of resveratrol was measured in 10 common solvents at 25 °C using HPLC. The solution state pH stability of resveratrol was assessed in various United States Pharmacopeia buffers ranging from pH 2 to 10 for 24 h at 37 °C. Samples were analyzed up to 24 h. Human PPB was determined using ultracentrifugation technique. Standard solutions of drug were spiked to blank human plasma to yield final concentrations of 5, 12.5 or 25 µg/mL for determination. Finally, stability of resveratrol in human and rat plasma was also assessed at 37 °C. Aliquots of blank plasma were spiked with a standard drug concentration to yield final plasma concentration of 50 µg/mL. Samples were analyzed for resveratrol concentration up to 96 h. Results Resveratrol has wide solubility ranging from 0.05 mg/mL in water to 374 mg/mL in polyethylene glycol 400 (PEG-400). Resveratrol is relatively stable above pH 6 and has maximum degradation at pH 9. The mean PPB of resveratrol is 98.3%. Resveratrol degrades in human and rat plasma in a first-order process with mean half lives of 54 and 25 h, respectively. Conclusion Resveratrol is more soluble in alcohol and PEG-400 and stable in acidic pH. It binds highly to plasma proteins and degrades slower in human then rat plasma. PMID:25224342

  18. Plasma endocannabinoid levels in lean, overweight and obese humans: relationships with intestinal permeability markers, inflammation and incretin secretion.

    PubMed

    Little, Tanya J; Cvijanovic, Nada; DiPatrizio, Nicholas V; Argueta, Donovan A; Rayner, Christopher K; Feinle-Bisset, Christine; Young, Richard L

    2018-02-13

    Intestinal production of endocannabinoid and oleoylethanolamide (OEA) is impaired in high-fat diet/obese rodents, leading to reduced satiety. Such diets also alter the intestinal microbiome in association with enhanced intestinal permeability and inflammation, however little is known of these effects in humans. This study aimed to: (i) evaluate effects of lipid on plasma anandamide (AEA), 2-arachidonyl-sn-glycerol (2-AG) and OEA in humans, and (ii) examine relationships with intestinal permeability, inflammation markers and incretin hormone secretion. 20 lean, 18 overweight and 19 obese participants underwent intraduodenal Intralipid® infusion (2 kcal/min) with collection of endoscopic duodenal biopsies and blood. Plasma AEA, 2-AG, and OEA (HPLC/tandem mass spectrometry), tumour necrosis factor-α (TNF-α), glucagon-like peptide-1 (GLP-1) and glucose-dependent insulinotropic peptide (GIP) (multiplex), and duodenal expression of occludin, zona-occludin-1 (ZO-1), intestinal-alkaline-phosphatase (IAP), and toll-like receptor-4 (TLR4) (RT-PCR), were assessed. Fasting plasma AEA was increased in obese, compared with lean and overweight (P<0.05), with no effect of BMI group or ID lipid infusion on plasma 2-AG or OEA. Duodenal expression of IAP and ZO-1 was reduced in obese, compared with lean (P<0.05), and these levels related negatively to plasma AEA (P<0.05). The iAUC for AEA was positively related to iAUC GIP (r=0.384, P=0.005). Obese individuals have increased plasma AEA and decreased duodenal expression of ZO-1 and IAP, in comparison to lean and overweight. The relationships between plasma AEA with duodenal ZO-1 and IAP, and GIP, suggest that altered endocannabinoid signalling may contribute to changes in intestinal permeability, inflammation and incretin release in human obesity.

  19. Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma.

    PubMed

    Kennedy, Joseph H; Wiseman, Justin M

    2010-02-01

    The present work describes the methodology and investigates the performance of desorption electrospray ionization (DESI) combined with a triple quadrupole mass spectrometer for the quantitation of small drug molecules in human plasma. Amoxepine, atenolol, carbamazepine, clozapine, prazosin, propranolol and verapamil were selected as target analytes while terfenadine was selected as the internal standard common to each of the analytes. Protein precipitation of human plasma using acetonitrile was utilized for all samples. Limits of detection were determined for all analytes in plasma and shown to be in the range 0.2-40 ng/mL. Quantitative analysis of amoxepine, prazosin and verapamil was performed over the range 20-7400 ng/mL and shown to be linear in all cases with R(2) >0.99. In most cases, the precision (relative standard deviation) and accuracy (relative error) of each method were less than or equal to 20%, respectively. The performance of the combined techniques made it possible to analyze each sample in 15 s illustrating DESI tandem mass spectrometry (MS/MS) as powerful tool for the quantitation of analytes in deproteinized human plasma. Copyright 2010 John Wiley & Sons, Ltd.

  20. Determination of N-(trans-4-isopropylcyclohexylcarbonyl)-D-phenylalanine in human plasma by solid-phase extraction and column-switching high-performance liquid chromatography with ultraviolet detection.

    PubMed

    Ono, I; Matsuda, K; Kanno, S

    1996-04-12

    A column-switching high-performance liquid chromatography method with ultraviolet detection at 210 nm has been developed for the determination of N-(trans-4-isopropylcyclohexylcarbonyl)-D-phenylalanine (AY4166, I) in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak Light tC18, followed by HPLC. The calibration graph for I was linear in the range 0.1-20 micrograms/ml. The limit of quantitation of I, in plasma, was 0.05 microgram/ml. The recovery of spiked I (0.5 microgram/ml) to drug-free plasma was over 92% and the relative standard deviation of spiked I (0.5 microgram/ml) compared to drug-free plasma was 4.3% (n = 8).

  1. Synthetic peptides and fluorogenic substrates related to the reactive site sequence of Kunitz-type inhibitors isolated from Bauhinia: interaction with human plasma kallikrein.

    PubMed

    Oliva, M L; Santomauro-Vaz, E M; Andrade, S A; Juliano, M A; Pott, V J; Sampaio, M U; Sampaio, C A

    2001-01-01

    We have previously described Kunitz-type serine proteinase inhibitors purified from Bauhinia seeds. Human plasma kallikrein shows different susceptibility to those inhibitors. In this communication, we describe the interaction of human plasma kallikrein with fluorogenic and non-fluorogenic peptides based on the Bauhinia inhibitors' reactive site. The hydrolysis of the substrate based on the B. variegata inhibitor reactive site sequence, Abz-VVISALPRSVFIQ-EDDnp (Km 1.42 microM, kcat 0.06 s(-1), and kcat/Km 4.23 x 10(4) M(-1) s(-1)), is more favorable than that of Abz-VMIAALPRTMFIQ-EDDnp, related to the B. ungulata sequence (Km 0.43 microM, kcat 0.00017 s(-1), and kcat/Km 3.9 x 10(2) M(-1) s(-1)). Human plasma kallikrein does not hydrolyze the substrates Abz-RPGLPVRFESPL-EDDnp and Abz-FESPLRINIIKE-EDDnp based on the B. bauhinioides inhibitor reactive site sequence, the most effective inhibitor of the enzyme. These peptides are competitive inhibitors with Ki values in the nM range. The synthetic peptide containing 19 amino acids based on the B. bauhinioides inhibitor reactive site (RPGLPVRFESPL) is poorly cleaved by kallikrein. The given substrates are highly specific for trypsin and chymotrypsin hydrolysis. Other serine proteinases such as factor Xa, factor XII, thrombin and plasmin do not hydrolyze B. bauhinioides inhibitor related substrates.

  2. Simple Quantification of Pentosidine in Human Urine and Plasma by High-Performance Liquid Chromatography

    PubMed Central

    Lee, Ji Sang; Chung, Yoon-Sok; Chang, Sun Young

    2017-01-01

    Pentosidine is an advanced glycation end-product (AGE) and fluorescent cross-link compound. A simple high-performance liquid chromatographic (HPLC) method was developed for the detection and quantification of pentosidine in human urine and plasma. The mobile phase used a gradient system to improve separation of pentosidine from endogenous peaks, and chromatograms were monitored by fluorescent detector set at excitation and emission wavelengths of 328 and 378 nm, respectively. The retention time for pentosidine was 24.3 min and the lower limits of quantification (LLOQ) in human urine and plasma were 1 nM. The intraday assay precisions (coefficients of variation) were generally low and found to be in the range of 5.19–7.49% and 4.96–8.78% for human urine and plasma, respectively. The corresponding values of the interday assay precisions were 9.45% and 4.27%. Accuracies (relative errors) ranged from 87.9% to 115%. Pentosidine was stable in a range of pH solutions, human urine, and plasma. In summary, this HPLC method can be applied in future preclinical and clinical evaluation of pentosidine in the diabetic patients. PMID:29181026

  3. Quantitative determination of galantamine in human plasma by sensitive liquid chromatography-tandem mass spectrometry using loratadine as an internal standard.

    PubMed

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh

    2007-02-01

    A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.

  4. Analytical methods involving separation techniques for determination of low-molecular-weight biothiols in human plasma and blood.

    PubMed

    Isokawa, Muneki; Kanamori, Takahiro; Funatsu, Takashi; Tsunoda, Makoto

    2014-08-01

    Low-molecular-weight biothiols such as homocysteine, cysteine, and glutathione are metabolites of the sulfur cycle and play important roles in biological processes such as the antioxidant defense network, methionine cycle, and protein synthesis. Thiol concentrations in human plasma and blood are related to diseases such as cardiovascular disease, neurodegenerative disease, and cancer. The concentrations of homocysteine, cysteine, and glutathione in plasma samples from healthy human subjects are approximately in the range of 5-15, 200-300, and 1-5 μM, respectively. Glutathione concentration in the whole blood is in the millimolar range. Measurement of biothiol levels in plasma and blood is thought to be important for understanding the physiological roles and biomarkers for certain diseases. This review summarizes the relationship of biothiols with certain disease as well as pre-analytical treatment and analytical methods for determination of biothiols in human plasma and blood by using high-performance liquid chromatography and capillary electrophoresis coupled with ultraviolet, fluorescence, or chemiluminescence detection; or mass spectrometry. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. The plasma and cerebrospinal fluid pharmacokinetics of erlotinib and its active metabolite (OSI-420) after intravenous administration of erlotinib in non-human primates.

    PubMed

    Meany, Holly J; Fox, Elizabeth; McCully, Cynthia; Tucker, Chris; Balis, Frank M

    2008-08-01

    Erlotinib hydrochloride is a small molecule inhibitor of epidermal growth factor receptor (EGFR). EGFR is over-expressed in primary brain tumors and solid tumors that metastasize to the central nervous system. We evaluated the plasma and cerebrospinal fluid (CSF) pharmacokinetics of erlotinib and its active metabolite OSI-420 after an intravenous (IV) dose in a non-human primate model. Erlotinib was administered as a 1 h IV infusion to four adult rhesus monkeys. Serial blood and CSF samples were drawn over 48 h and erlotinib and OSI-420 were quantified with an HPLC/tandem mass spectroscopic assay. Pharmacokinetic parameters were estimated using non-compartmental and compartmental methods. CSF penetration was calculated from the AUC(CSF):AUC(plasma). Erlotinib disappearance from plasma after a short IV infusion was biexponential with a mean terminal half-life of 5.2 h and a mean clearance of 128 ml/min per m(2). OSI-420 exposure (AUC) in plasma was 30% (range 12-59%) of erlotinib, and OSI-420 clearance was more than 5-fold higher than erlotinib. Erlotinib and OSI-420 were detectable in CSF. The CSF penetration (AUC(CSF):AUC(plasma)) of erlotinib and OSI-420 was <5% relative to total plasma concentration, but CSF drug exposure was approximately 30% of plasma free drug exposure, which was calculated from published plasma protein binding values. The IV administration of erlotinib was well tolerated. Erlotinib and its active metabolite OSI-420 are measurable in CSF after an IV dose. The drug exposure (AUC) in the CSF is limited relative to total plasma concentrations but is substantial relative the free drug exposure in plasma.

  6. Application of a novel liquid chromatography/tandem mass spectrometry method for the determination of antazoline in human plasma: Result of ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study.

    PubMed

    Giebułtowicz, Joanna; Piotrowski, Roman; Baran, Jakub; Kułakowski, Piotr; Wroczyński, Piotr

    2016-05-10

    Antazoline is a first-generation antihistaminic agent with antiarrhythmic quinidine-like properties. In some countries, it is widely used for termination of cardiac arrhythmias, especially atrial fibrillation (AF). However, no human pharmacokinetic studies have been conducted with intravenous antazoline. The aim of our study was to develop and validate a novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of antazoline in human plasma: the ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study. Antazoline was extracted from plasma using liquid-liquid extraction. The concentration of the analyte was measured by LC-MS/MS with xylometazoline as an internal standard. The method was validated for linearity, precision, accuracy, stability (freeze/thaw stability, stability in autosampler, short and long term stability), dilution integrity and matrix effect. The analyzed validation criteria were fulfilled. The method was applied to a pharmacokinetic study involving 10 healthy volunteers. Following a single intravenous dose of antazoline mesylate (100 mg), the plasma concentration profile showed a relative fast elimination with a terminal elimination half-life of 2.29 h. A relatively high volume of distribution was observed (Vss=315 L). The values of mean residence time (MRT∞), area under the curve (AUC∞) and clearance were 3.45 h, 0.91 mg h L(-1) and 80.5 L h(-1), respectively. One volunteer showed significant differences in pharmacokinetic parameters. In conclusion, the proposed new LC-MS/MS method was successfully used for the first time for the determination of antazoline in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Selective cytotoxic effect of non-thermal micro-DBD plasma

    NASA Astrophysics Data System (ADS)

    Kwon, Byung-Su; Choi, Eun Ha; Chang, Boksoon; Choi, Jeong-Hyun; Kim, Kyung Sook; Park, Hun-Kuk

    2016-10-01

    Non-thermal plasma has been extensively researched as a new cancer treatment technology. We investigated the selective cytotoxic effects of non-thermal micro-dielectric barrier discharge (micro-DBD) plasma in cervical cancer cells. Two human cervical cancer cell lines (HeLa and SiHa) and one human fibroblast (HFB) cell line were treated with micro-DBD plasma. All cells underwent apoptotic death induced by plasma in a dose-dependent manner. The plasma showed selective inhibition of cell proliferation in cervical cancer cells compared to HFBs. The selective effects of the plasma were also observed between the different cervical cancer cell lines. Plasma treatment significantly inhibited the proliferation of SiHa cells in comparison to HeLa cells. The changes in gene expression were significant in the cervical cancer cells in comparison to HFBs. Among the cancer cells, apoptosis-related genes were significantly enriched in SiHa cells. These changes were consistent with the differential cytotoxic effects observed in different cell lines.

  8. [Enantioselectivity in the excretion of glucuronides of carprofen in man, dogs and horses].

    PubMed

    Delatour, P; Garnier, F; Maire, R

    1996-10-01

    After administration of the racemic drug, the stereoselective quantification of the enantiomers of free and conjugated carprofen was performed in human plasma and in plasma, urine and bile of dogs and horses. In humans, the plasma profile of free carprofen and its glucuronides is not stereoselective and the glucuronides excreted in urine are close to a racemate. In dogs and horses on the contrary, the R(-) enantiomer of the free drug is predominant in plasma, while urine and/or bile concentrations of the glucuronides are high in comparison to plasma with a strong selectivity for the S(+) enantiomer. Because glucuronidation of carprofen, as a carboxylic compound, is known to be the major metabolic pathway in most species, interspecies discrepancies in the stereoselective disposition of carprofen seem to be mainly related to the stereoselectivity in the excretion of the glucuronides. Finally, the high plasma concentrations of carprofen glucuronides in human in comparison to other animal species suggest that the former could be specifically subjected to immunological side effects in the time course of treatments by this type of compounds.

  9. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    PubMed

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Physical, chemical, biological, and biotechnological sciences are incomplete without each other

    USDA-ARS?s Scientific Manuscript database

    Chemical analysis and chromatographic techniques could not separate plasma lipoproteins which are now known as cholesterol- containing, heart-disease related macromolecules in human blood. Scientists at the Lawrence Berkeley Laboratory successfully separated plasma lipoproteins using equilibrium den...

  11. Effects of Behavioral Stimuli on Plasma Interleukin-1 Activity in Humans at Rest.

    ERIC Educational Resources Information Center

    Keppel, William H.; And Others

    1993-01-01

    Performed Interleukin-1 (IL-1) bioassays on 208 serum samples from seven volunteers at 5-minute intervals before, during, and after relaxation-related behavioral stimulus. Individuals showed up to 267% increase in IL-1, and for group mean, 48.1% elevation occurred, during stimulus interval relative to baseline. Such changes in plasma IL-1,…

  12. A lectin-coupled, targeted proteomic mass spectrometry (MRM MS) platform for identification of multiple liver cancer biomarkers in human plasma.

    PubMed

    Ahn, Yeong Hee; Shin, Park Min; Oh, Na Ree; Park, Gun Wook; Kim, Hoguen; Yoo, Jong Shin

    2012-09-18

    Aberrantly glycosylated proteins related to liver cancer progression were captured with specific lectin and identified from human plasma by multiple reaction monitoring (MRM) mass spectrometry as multiple biomarkers for hepatocellular carcinoma (HCC). The lectin fractionation for fucosylated protein glycoforms in human plasma was conducted with a fucose-specific aleuria aurantia lectin (AAL). Following tryptic digestion of the lectin-captured fraction, plasma samples from 30 control cases (including 10 healthy, 10 hepatitis B virus [HBV], and 10 cirrhosis cases) and 10 HCC cases were quantitatively analyzed by MRM to identify which glycoproteins are viable HCC biomarkers. A1AG1, AACT, A1AT, and CERU were found to be potent biomarkers to differentiate HCC plasma from control plasmas. The AUROC generated independently from these four biomarker candidates ranged from 0.73 to 0.92. However, the lectin-coupled MRM assay with multiple combinations of biomarker candidates is superior statistically to those generated from the individual candidates with AUROC more than 0.95, which can be an alternative to the immunoassay inevitably requiring tedious development of multiple antibodies against biomarker candidates to be verified. Eventually the lectin-coupled, targeted proteomic mass spectrometry (MRM MS) platform was found to be efficient to identify multiple biomarkers from human plasma according to cancer progression. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Efficient lowering of triglyceride levels in mice by human apoAV protein variants associated with hypertriglyceridemia.

    PubMed

    Vaessen, Stefan F C; Sierts, Jeroen A; Kuivenhoven, Jan Albert; Schaap, Frank G

    2009-02-06

    Variation in the apolipoprotein A5 (APOA5) gene has consistently been associated with increased plasma triglyceride (TG) levels in epidemiological studies. In vivo functionality of these variations, however, has thus far not been tested. Using adenoviral over-expression, we evaluated plasma expression levels and TG-lowering efficacies of wild-type human apoAV, two human apoAV variants associated with increased TG (S19W, G185C) and one variant (Q341H) that is predicted to have altered protein function. Injection of mice with adenovirus encoding wild-type or mutant apoAV resulted in an identical dose-dependent elevation of human apoAV levels in plasma. The increase in apoAV levels resulted in pronounced lowering of plasma TG levels at two viral dosages. Unexpectedly, the TG-lowering efficacy of all three apoAV variants was similar to wild-type apoAV. In addition, no effect on TG-hydrolysis-related plasma parameters (free fatty acids, glycerol and post-heparin lipoprotein lipase activity) was apparent upon expression of all apoAV variants. In conclusion, our data indicate that despite their association with hypertriglyceridemia and/or predicted protein dysfunction, the 19W, 185C and 341H apoAV variants are equally effective in reducing plasma TG levels in mice.

  14. Monitoring of treatment with vitamin K antagonists: recombinant thromboplastins are more sensitive to factor VII than tissue-extract thromboplastins.

    PubMed

    Biedermann, J S; van den Besselaar, A M H P; de Maat, M P M; Leebeek, F W G; Kruip, M J H A

    2017-03-01

    Essentials Differences in sensitivity to factor VII (FVII) have been suggested between thromboplastins. FVII-induced International Normalized Ratio (INR) changes differ between commercial reagents. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Thromboplastin choice may affect FVII-mediated INR stability. Background Differences regarding sensitivity to factor VII have been suggested for recombinant human and tissue-extract thromboplastins used for International Normalized Ratio (INR) measurement, but the evidence is scarce. Differences in FVII sensitivity are clinically relevant, as they can affect INR stability during treatment with vitamin K antagonists (VKAs). Objectives To determine whether commercial thromboplastins react differently to changes in FVII. Methods We studied the effect of addition of FVII on the INR in plasma by using three tissue-extract (Neoplastin C1+, Hepato Quick, and Thromborel S) and three recombinant human (Recombiplastin 2G, Innovin, and CoaguChek XS) thromboplastins. Three different concentrations of purified human FVII (0.006, 0.012 and 0.062 μg mL -1 plasma), or buffer, were added to five certified pooled plasmas of patients using VKAs (INR of 1.5-3.5). Changes in FVII activity were measured with two bioassays (Neoplastin and Recombiplastin), and relative INR changes were compared between reagents. Results After addition of 0.062 μg mL -1 FVII, FVII activity in the pooled plasmas increased by approximately 20% (Neoplastin) or 32% (Recombiplastin) relative to the activity in pooled normal plasma. All thromboplastins showed dose-dependent INR decreases. The relative INR change in the pooled plasmas significantly differed between the six thromboplastins. No differences were observed among recombinant or tissue-extract thromboplastins. Pooled results indicated that the FVII-induced INR change was greater for recombinant than for tissue-extract thromboplastins. Conclusions Differences regarding FVII sensitivity exist between various thromboplastins used for VKA monitoring. Recombinant human thromboplastins are more sensitive to FVII than tissue-extract thromboplastins. Therefore, thromboplastin choice may affect FVII-mediated INR stability. © 2017 International Society on Thrombosis and Haemostasis.

  15. Partitioning of human and sheep forms of the pathogenic prion protein during the purification of therapeutic proteins from human plasma.

    PubMed

    Stenland, Christopher J; Lee, Douglas C; Brown, Paul; Petteway, Stephen R; Rubenstein, Richard

    2002-11-01

    Therapeutic proteins derived from human plasma and other biologic sources have demonstrated an excellent safety record relative to the potential threat of transmissible spongiform encephalopathy (TSE) transmission. Previously, hamster-adapted scrapie was used as a model agent to assess TSE clearance in purification steps leading to the isolation of biopharmaceutical proteins. The current study investigated the validity of hamster scrapie as a model for human TSE clearance studies. The partitioning of the pathogenic forms of the prion protein associated with human variant CJD (PrP(vCJD)), human sporadic CJD (PrP(sCJD)) and Gerstmann-Sträussler-Scheinker (PrP(GSS)) syndrome was compared to the partitioning of hamster scrapie (PrP(Sc)) in three plasma protein purification steps. Sheep scrapie (PrP(Sc)) was similarly evaluated. The starting materials for three plasma protein purification steps, cryoseparation, 3 percent PEG separation, and 11.5 percent PEG separation, were spiked with brain homogenates containing human PrP(vCJD), human PrP(sCJD), human PrP(GSS), sheep PrP(Sc), and hamster 263K PrP(Sc). The partitioning of the pathogenic form of the PrP was analyzed. Clearance of the pathogenic form of the PrP was measured relative to the effluent fraction. Regardless of the source of the pathogenic prion, clearance was similar to hamster PrP(Sc). A nominal amount of clearance (approx., 1 log), an intermediate amount of clearance (approx., 2 log), and a substantial amount of clearance (> or = 3 log) were observed for the cryoseparation, 3 percent PEG separation, and 11.5 percent PEG separation steps, respectively. In the latter step, no PrP was detected in the effluents. These data demonstrate that human prions, including vCJD prions, can be removed during the purification of human therapeutic proteins and indicate that partitioning of human prions is similar to that observed in the hamster scrapie model.

  16. Mammalian monoamine-oxidizing enzymes, with special reference to benzylamine oxidase in human tissues.

    PubMed

    Lewinsohn, R

    1984-01-01

    A review is presented of the monoamine-oxidizing enzymes with special reference to the activity of benzylamine oxidase (BzAO) in human tissues. Methods of study of amine oxidases, properties (chiefly of BzAO) and some problems concerning substrate and inhibitor specificity and multiple forms of monoamine oxidase (MAO) are surveyed. The substrate specificity of human plasma BzAO is compared with that of amine-oxidizing enzymes in plasma or serum of other species. Correlations of plasma BzAO and platelet MAO activity with clinical findings are discussed. The distribution of amine oxidase activities in solid human tissues is reviewed, in particular BzAO in blood vessels and richly-vascularized tissues, as well as kinetic constants and altered patterns of activity of BzAO in human atherosclerosis. Activities of the amine oxidases in non-vascular smooth muscle, in cultured cells, and in various tissues related to human gestation, are discussed. The present knowledge of BzAO is discussed in terms of its possible clinical relevance to several human disease states, and the importance of the enzyme in the human body.

  17. Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode

    NASA Astrophysics Data System (ADS)

    Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min

    2016-03-01

    Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death.

  18. Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode

    PubMed Central

    Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min

    2016-01-01

    Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death. PMID:27006081

  19. A Simple and Sensitive LC-MS/MS Method for Determination of Four Major Active Diterpenoids from Andrographis paniculata in Human Plasma and Its Application to a Pilot Study.

    PubMed

    Pholphana, Nanthanit; Panomvana, Duangchit; Rangkadilok, Nuchanart; Suriyo, Tawit; Ungtrakul, Teerapat; Pongpun, Wanwisa; Thaeopattha, Saichit; Satayavivad, Jutamaad

    2016-01-01

    Andrographis paniculata contains four major active diterpenoids, including andrographolide (1), 14-deoxy-11, 12-didehydroandrographolide (2), neoandrographolide (3), and 14-deoxyandrographolide (4), which exhibit differences in types and/or degrees of their pharmacological activity. Previous pharmacokinetic studies in humans reported only the parameters of compound 1 and its analytical method in human plasma. The purpose of this study was to develop a simple, sensitive, and selective liquid chromatography tandem-mass spectrometry technique for the simultaneous determination of all four major active diterpenoids in the A. paniculata product in human plasma. These four diterpenoids in plasma samples were extracted by a simple protein precipitation method with methanol and separated on a Kinetex C18 column using a gradient system with a mobile phase of acetonitrile and water. The liquid chromatography tandem-mass spectrometry was performed in the negative mode, and the multiple reaction monitoring mode was used for the quantitation. The method showed a good linearity over a wide concentration range of 2.50-500 ng/mL for 1 and over the range of 1.00-500 ng/mL for the other diterpenoids with a correlation coefficient R(2) > 0.995. The lower limit of quantification of 1 was found to be 2.50 ng/mL, while those of the other diterpenoids were 1.00 ng/mL. The intraday and interday accuracy (relative error) ranged from 0.03 % to 10.03 %, and the intraday and interday precisions (relative standard deviation) were in the range of 2.05-9.67 %. The extraction recovery (86.54-111.56 %) with a relative standard deviation of 2.78-8.61 % and the matrix effect (85.15-112.36 %) were within the acceptance criteria. Moreover, these four major active diterpenoids were stable in plasma samples at the studied storage conditions with a relative error ≤-9.79 % and a relative standard deviation ≤ 9.26 %. Hence, this present method was successfully validated and used in the pilot study to determine the pharmacokinetic parameters of all four major active diterpenoids in human plasma after multiple oral doses of the A. paniculata product were administered to a healthy, Thai female volunteer. Georg Thieme Verlag KG Stuttgart · New York.

  20. Effects of dietary sesame seeds on plasma tocopherol levels.

    PubMed

    Cooney, R V; Custer, L J; Okinaka, L; Franke, A A

    2001-01-01

    The tocopherols, the major vitamers of vitamin E, are believed to play a role in the prevention of human aging-related diseases such as cancer and heart disease, yet little is known concerning determinants of their plasma concentrations. Evidence from animal studies suggests that the dietary source of gamma-tocopherol can significantly affect plasma levels of this tocopherol as well as its functional vitamin E activity. To determine whether plasma levels of tocopherols in humans are similarly altered, a study was undertaken in which subjects (n = 9) were fed muffins containing equivalent amounts of gamma-tocopherol from sesame seeds, walnuts, or soy oil. We observed that consumption of as little as 5 mg of gamma-tocopherol per day over a three-day period from sesame seeds, but not from walnuts or soy oil, significantly elevated serum gamma-tocopherol levels (19.1% increase, p = 0.03) and depressed plasma beta-tocopherol (34% decrease, p = 0.01). No significant changes in baseline or postintervention plasma levels of cholesterol, triglycerides, or carotenoids were seen for any of the intervention groups. All subjects consuming sesame seed-containing muffins had detectable levels of the sesame lignan sesamolin in their plasma. Consumption of moderate amounts of sesame seeds appears to significantly increase plasma gamma-tocopherol and alter plasma tocopherol ratios in humans and is consistent with the effects of dietary sesame seeds observed in rats leading to elevated plasma gamma-tocopherol and enhanced vitamin E bioactivity.

  1. Radioimmunoassay determinations of p-hydroxyphenformin and of apparent phenformin in human plasma or serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alkalay, D.; Khemani, L.; Bartlett, M.F.

    1978-01-01

    Sensitive radioimmunoassay procedures are described for measuring p-hydroxyphenformin and apparent phenformin in human plasma or serum. The p-hydroxyphenformin procedure, which requires advance phenformin analysis, offers excellent accuracy. The determinations of apparent phenformin are influenced by the phenformin and p-hydroxyphenformin contents of the samples. Over a period of four months, the methods showed a precision associated with relative standard deviations of 12% for apparent phenformin and 13% for p-hydroxyphenformin.

  2. Argininosuccinate synthetase as a plasma biomarker of liver injury after acetaminophen overdose in rodents and humans

    PubMed Central

    McGill, Mitchell R.; Cao, Mengde; Svetlov, Archie; Sharpe, Matthew R.; Williams, C. David; Curry, Steven C.; Farhood, Anwar; Jaeschke, Hartmut; Svetlov, Stanislav I.

    2014-01-01

    Context New biomarkers are needed in acetaminophen (APAP) hepatotoxicity. Plasma argininosuccinate synthetase (ASS) is a promising candidate. Objective Characterize ASS in APAP hepatotoxicity. Methods ASS was measured in plasma from rodents and humans with APAP hepatotoxicity. Results In mice, ASS increased before injury, peaked before ALT, and decreased rapidly. Fischer rats had a greater increase in ASS relative to ALT. Patients with abnormal liver test results had very high ASS compared to controls. ASS appeared to increase early in some patients, and declined rapidly in all. Conclusions : ASS may be a useful biomarker of acute cell death in APAP hepatotoxicity. PMID:24597531

  3. Age-related alterations of plasma glutathione and oxidation of redox potentials in chimpanzee (Pan troglodytes) and rhesus monkey (Macaca mulatta).

    PubMed

    Paredes, Jamespaul; Jones, Dean P; Wilson, Mark E; Herndon, James G

    2014-04-01

    Chimpanzee (Pan troglodytes) and rhesus macaque (Macaca mulatta) and humans (Homo sapiens) share physiological and genetic characteristics, but have remarkably different life spans, with chimpanzees living 50-60 % and the rhesus living 35-40 % of maximum human survival. Since oxidative processes are associated with aging and longevity, we might expect to see species differences in age-related oxidative processes. Blood and extracellular fluid contain two major thiol redox nodes, glutathione (GSH)/glutathione-disulfide (GSSG) and cysteine (Cys)/cystine (CySS), which are subject to reversible oxidation-reduction reactions and are maintained in a dynamic non-equilibrium state. Disruption of these thiol redox nodes leads to oxidation of their redox potentials (EhGSSG and EhCySS) which affects cellular physiology and is associated with aging and the development of chronic diseases in humans. The purpose of this study was to measure age-related changes in these redox thiols and their corresponding redox potentials (Eh) in chimpanzees and rhesus monkeys. Our results show similar age-related decreases in the concentration of plasma GSH and Total GSH as well as oxidation of the EhGSSG in male and female chimpanzees. Female chimpanzees and female rhesus monkeys also were similar in several outcome measures. For example, similar age-related decreases in the concentration of plasma GSH and Total GSH, as well as age-related oxidation of the EhGSSG were observed. The data collected from chimpanzees and rhesus monkeys corroborates previous reports on oxidative changes in humans and confirms their value as a comparative reference for primate aging.

  4. GC-MS Quantification Method for Mephedrone in Plasma and Urine: Application to Human Pharmacokinetics.

    PubMed

    Olesti, Eulàlia; Pujadas, Mitona; Papaseit, Esther; Pérez-Mañá, Clara; Pozo, Óscar J; Farré, Magí; de la Torre, Rafael

    2017-03-01

    Increasing consumption has been observed among young people of new psychoactive substances, including synthetic cathinone derivatives. The most well known of these is mephedrone whose use has been related to acute intoxication and fatality. Several methods able to detect mephedrone have been reported, although to date, none have been applied to human pharmacokinetic studies in a controlled setting. We developed a gas chromatography-mass spectrometry technique for mephedrone quantification in human plasma and urine. Plasma after deproteinization and urine were submitted to a liquid-liquid extraction and derivatization of the extract with MSTFA prior to analysis. Calibration curves covered concentration ranges in plasma between 5 and 300 ng/mL and in urine between 20 and 1,500 ng/mL. The method has been successfully applied to biological samples obtained from a pilot clinical trial intended to evaluate the human pharmacology of mephedrone and its relative bioavailability and pharmacokinetics. Six healthy males were administered 150 mg of mephedrone by the oral route in a randomized, double-blind, cross-over controlled trial. Peak plasma concentration (Cmax = 122.6 ± 32.9 ng/mL) was reached at 1 hour (0.5-2 h) post-drug administration. Mephedrone showed a rapid elimination half-life (t1/2 = 2.2 h) compared to other psychostimulants. Less than 15% of the dose was excreted in urine as a free-form. Mephedrone concentrations displayed a relevant inter-subject variability. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Determination of 4-nonylphenol and 4-octylphenol in human blood samples by high-performance liquid chromatography with multi-electrode electrochemical coulometric-array detection.

    PubMed

    Inoue, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-01

    Alkylphenols can affect human health because they disrupt the endocrine system. In this study, an analytical method for determining trace amounts of 4-nonylphenol (NP) and 4-octylphenol (OP) in human blood samples was developed. Reversed-phase HPLC with multi-electrode electrochemical coulometric-array detection was used for the determination of NP and OP in plasma and serum samples prepared with a solid-phase extraction method. The separation was achieved using an isocratic mobile phase of 0.7% phosphoric acid-acetonitrile with a C18 reversed phase column. The detection limits of NP and OP were 1.0 and 0.5 ng ml-1, respectively. The recoveries of NP and OP added to human plasma samples were above 70.0% with a relative standard deviation of less than 15.5%. The method was found to be applicable to the determination of NP and OP in various human blood samples such as serum and plasma.

  6. Identification of Trypanosome Proteins in Plasma from African Sleeping Sickness Patients Infected with T. b. rhodesiense

    PubMed Central

    Enyaru, John C.; Carr, Steven A.; Pearson, Terry W.

    2013-01-01

    Control of human African sleeping sickness, caused by subspecies of the protozoan parasite Trypanosoma brucei, is based on preventing transmission by elimination of the tsetse vector and by active diagnostic screening and treatment of infected patients. To identify trypanosome proteins that have potential as biomarkers for detection and monitoring of African sleeping sickness, we have used a ‘deep-mining” proteomics approach to identify trypanosome proteins in human plasma. Abundant human plasma proteins were removed by immunodepletion. Depleted plasma samples were then digested to peptides with trypsin, fractionated by basic reversed phase and each fraction analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This sample processing and analysis method enabled identification of low levels of trypanosome proteins in pooled plasma from late stage sleeping sickness patients infected with Trypanosoma brucei rhodesiense. A total of 254 trypanosome proteins were confidently identified. Many of the parasite proteins identified were of unknown function, although metabolic enzymes, chaperones, proteases and ubiquitin-related/acting proteins were found. This approach to the identification of conserved, soluble trypanosome proteins in human plasma offers a possible route to improved disease diagnosis and monitoring, since these molecules are potential biomarkers for the development of a new generation of antigen-detection assays. The combined immuno-depletion/mass spectrometric approach can be applied to a variety of infectious diseases for unbiased biomarker identification. PMID:23951171

  7. Identification of Trypanosome proteins in plasma from African sleeping sickness patients infected with T. b. rhodesiense.

    PubMed

    Eyford, Brett A; Ahmad, Rushdy; Enyaru, John C; Carr, Steven A; Pearson, Terry W

    2013-01-01

    Control of human African sleeping sickness, caused by subspecies of the protozoan parasite Trypanosoma brucei, is based on preventing transmission by elimination of the tsetse vector and by active diagnostic screening and treatment of infected patients. To identify trypanosome proteins that have potential as biomarkers for detection and monitoring of African sleeping sickness, we have used a 'deep-mining" proteomics approach to identify trypanosome proteins in human plasma. Abundant human plasma proteins were removed by immunodepletion. Depleted plasma samples were then digested to peptides with trypsin, fractionated by basic reversed phase and each fraction analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This sample processing and analysis method enabled identification of low levels of trypanosome proteins in pooled plasma from late stage sleeping sickness patients infected with Trypanosoma brucei rhodesiense. A total of 254 trypanosome proteins were confidently identified. Many of the parasite proteins identified were of unknown function, although metabolic enzymes, chaperones, proteases and ubiquitin-related/acting proteins were found. This approach to the identification of conserved, soluble trypanosome proteins in human plasma offers a possible route to improved disease diagnosis and monitoring, since these molecules are potential biomarkers for the development of a new generation of antigen-detection assays. The combined immuno-depletion/mass spectrometric approach can be applied to a variety of infectious diseases for unbiased biomarker identification.

  8. Comparison of subcutaneous soluble human insulin and insulin analogues (AspB9, GluB27; AspB10; AspB28) on meal-related plasma glucose excursions in type I diabetic subjects.

    PubMed

    Kang, S; Creagh, F M; Peters, J R; Brange, J; Vølund, A; Owens, D R

    1991-07-01

    To compare postprandial glucose excursions and plasma free insulin-analogue levels after subcutaneous injection of three novel human insulin analogues (AspB10; AspB9, GluB27; and AspB28) with those after injection of soluble human insulin (Actrapid HM U-100). Six male subjects with insulin-dependent diabetes, at least 1 wk apart and after an overnight fast and basal insulin infusion, received 72 nmol (approximately 12 U) s.c. of soluble human insulin 30 min before, or 72 nmol of each of the three analogues immediately before, a standard 500-kcal meal. Mean basal glucoses were similar on the 4 study days. Compared to human insulin (6.3 +/- 0.8 mM), mean +/- SE peak incremental glucose rises were similar after analogues AspB10 (5.4 +/- 0.8 mM) and AspB9, GluB27 (5.4 +/- 0.7 mM) and significantly lower after analogue AspB28 (3.6 +/- 1.2 mM, P less than 0.02). Relative to soluble human insulin (100% +/- SE21), incremental areas under the glucose curve between 0 and 240 min were 79% +/- 34 (AspB10, NS), 70% +/- 29 (AspB9, GluB27, NS), and 43% +/- 23 (AspB28, P less than 0.02). Basal plasma free insulin levels were similar on the 4 study days. Plasma free insulin-analogue levels rose rapidly to peak 30 min after injection at 308 +/- 44 pM (AspB10); 1231 +/- 190 pM (AspB9, GluB27) and 414 +/- 42 pM (AspB28) and were significantly higher than corresponding (i.e., 30 min postmeal) plasma free insulin levels of 157 +/- 15 pM (P less than 0.02 in each case). Plasma profiles of the insulin analogues were more physiological than that of human insulin after subcutaneous injection. All three analogues given immediately before the meal are at least as effective as soluble human insulin given 30 min earlier. These analogues are promising potential candidates for short-acting insulins of the future.

  9. Plasma Protein Corona Modulates the Vascular Wall Interaction of Drug Carriers in a Material and Donor Specific Manner

    PubMed Central

    Sobczynski, Daniel J.; Charoenphol, Phapanin; Heslinga, Michael J.; Onyskiw, Peter J.; Namdee, Katawut; Thompson, Alex J.; Eniola-Adefeso, Omolola

    2014-01-01

    The nanoscale plasma protein interaction with intravenously injected particulate carrier systems is known to modulate their organ distribution and clearance from the bloodstream. However, the role of this plasma protein interaction in prescribing the adhesion of carriers to the vascular wall remains relatively unknown. Here, we show that the adhesion of vascular-targeted poly(lactide-co-glycolic-acid) (PLGA) spheres to endothelial cells is significantly inhibited in human blood flow, with up to 90% reduction in adhesion observed relative to adhesion in simple buffer flow, depending on the particle size and the magnitude and pattern of blood flow. This reduced PLGA adhesion in blood flow is linked to the adsorption of certain high molecular weight plasma proteins on PLGA and is donor specific, where large reductions in particle adhesion in blood flow (>80% relative to buffer) is seen with ∼60% of unique donor bloods while others exhibit moderate to no reductions. The depletion of high molecular weight immunoglobulins from plasma is shown to successfully restore PLGA vascular wall adhesion. The observed plasma protein effect on PLGA is likely due to material characteristics since the effect is not replicated with polystyrene or silica spheres. These particles effectively adhere to the endothelium at a higher level in blood over buffer flow. Overall, understanding how distinct plasma proteins modulate the vascular wall interaction of vascular-targeted carriers of different material characteristics would allow for the design of highly functional delivery vehicles for the treatment of many serious human diseases. PMID:25229244

  10. Micro RNAs from DNA Viruses are Found Widely in Plasma in a Large Observational Human Population.

    PubMed

    Koupenova, Milka; Mick, Eric; Corkrey, Heather A; Huan, Tianxiao; Clancy, Lauren; Shah, Ravi; Benjamin, Emelia J; Levy, Daniel; Kurt-Jones, Evelyn A; Tanriverdi, Kahraman; Freedman, Jane E

    2018-04-23

    Viral infections associate with disease risk and select families of viruses encode miRNAs that control an efficient viral cycle. The association of viral miRNA expression with disease in a large human population has not been previously explored. We sequenced plasma RNA from 40 participants of the Framingham Heart Study (FHS, Offspring Cohort, Visit 8) and identified 3 viral miRNAs from 3 different human Herpesviridae. These miRNAs were mostly related to viral latency and have not been previously detected in human plasma. Viral miRNA expression was then screened in the plasma of 2763 participants of the remaining cohort utilizing high-throughput RT-qPCR. All 3 viral miRNAs associated with combinations of inflammatory or prothrombotic circulating biomarkers (sTNFRII, IL-6, sICAM1, OPG, P-selectin) but did not associate with hypertension, coronary heart disease or cancer. Using a large observational population, we demonstrate that the presence of select viral miRNAs in the human circulation associate with inflammatory biomarkers and possibly immune response, but fail to associate with overt disease. This study greatly extends smaller singular observations of viral miRNAs in the human circulation and suggests that select viral miRNAs, such as those for latency, may not impact disease manifestation.

  11. Changes in social functioning and circulating oxytocin and vasopressin following the migration to a new country.

    PubMed

    Gouin, Jean-Philippe; Pournajafi-Nazarloo, Hossein; Carter, C Sue

    2015-02-01

    Prior studies have reported associations between plasma oxytocin and vasopressin and markers of social functioning. However, because most human studies have used cross-sectional designs, it is unclear whether plasma oxytocin and vasopressin influences social functioning or whether social functioning modulates the production and peripheral release of these peptides. In order to address this question, we followed individuals who experienced major changes in social functioning subsequent to the migration to a new country. In this study, 59 new international students were recruited shortly after arrival in the host country and reassessed 2 and 5 months later. At each assessment participants provided information on their current social functioning and blood samples for oxytocin and vasopressin analysis. Results indicated that changes in social functioning were not related to changes in plasma oxytocin. Instead, baseline oxytocin predicted changes in social relationship satisfaction, social support, and loneliness over time. In contrast, plasma vasopressin changed as a function of social integration. Baseline vasopressin was not related to changes in social functioning over time. These results emphasize the different roles of plasma oxytocin and vasopressin in responses to changes in social functioning in humans. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Human umbilical cord plasma proteins revitalize hippocampal function in aged mice

    PubMed Central

    Castellano, Joseph M.; Mosher, Kira I.; Abbey, Rachelle J.; McBride, Alisha A.; James, Michelle L.; Berdnik, Daniela; Shen, Jadon C.; Zou, Bende; Xie, Xinmin S.; Tingle, Martha; Hinkson, Izumi V.; Angst, Martin S.; Wyss-Coray, Tony

    2017-01-01

    Ageing drives changes in neuronal and cognitive function, the decline of which is a major feature of many neurological disorders. The hippocampus, a brain region subserving roles of spatial and episodic memory and learning, is sensitive to the detrimental effects of ageing at morphological and molecular levels. With advancing age, synapses in various hippocampal subfields exhibit impaired long-term potentiation1, an electrophysiological correlate of learning and memory. At the molecular level, immediate early genes are among the synaptic plasticity genes that are both induced by long-term potentiation2, 3, 4 and downregulated in the aged brain5, 6, 7, 8. In addition to revitalizing other aged tissues9, 10, 11, 12, 13, exposure to factors in young blood counteracts age-related changes in these central nervous system parameters14, 15, 16, although the identities of specific cognition-promoting factors or whether such activity exists in human plasma remains unknown17. We hypothesized that plasma of an early developmental stage, namely umbilical cord plasma, provides a reservoir of such plasticity-promoting proteins. Here we show that human cord plasma treatment revitalizes the hippocampus and improves cognitive function in aged mice. Tissue inhibitor of metalloproteinases 2 (TIMP2), a blood-borne factor enriched in human cord plasma, young mouse plasma, and young mouse hippocampi, appears in the brain after systemic administration and increases synaptic plasticity and hippocampal-dependent cognition in aged mice. Depletion experiments in aged mice revealed TIMP2 to be necessary for the cognitive benefits conferred by cord plasma. We find that systemic pools of TIMP2 are necessary for spatial memory in young mice, while treatment of brain slices with TIMP2 antibody prevents long-term potentiation, arguing for previously unknown roles for TIMP2 in normal hippocampal function. Our findings reveal that human cord plasma contains plasticity-enhancing proteins of high translational value for targeting ageing- or disease-associated hippocampal dysfunction. PMID:28424512

  13. Systematic Evaluation of the Use of Human Plasma and Serum for Mass-Spectrometry-Based Shotgun Proteomics.

    PubMed

    Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc

    2018-04-06

    Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.

  14. Effects of chemosignals from sad tears and postprandial plasma on appetite and food intake in humans.

    PubMed

    Oh, Tae Jung; Kim, Min Young; Park, Kyong Soo; Cho, Young Min

    2012-01-01

    Chemosignals from human body fluids may modulate biological functions in humans. The objective of this study was to examine whether chemosignals from human sad tears and postprandial plasma modulate appetite. We obtained fasting and postprandial plasma from male participants and sad tears and saline, which was trickled below the eyelids, from female volunteers. These samples were then randomly distributed to male participants to sniff with a band-aid containing 100 µl of each fluid on four consecutive days in a double-blind fashion. We checked appetite by a visual analogue scale (VAS) and food intake by measuring the consumption of a test meal. In addition, the serum levels of total testosterone and LH were measured. Twenty men (mean age 26.3±4.6 years) were enrolled in this study. They could not discriminate between the smell of fasting and postprandial plasma and the smell of sad tears and trickled saline. Appetite and the amount of food intake were not different between the groups. Although the VAS ratings of appetite correlated with the food intake upon sniffing fasting plasma, postprandial plasma, and trickled saline, there was no such correlation upon sniffing sad tears. In addition, the decrease in serum testosterone levels from the baseline was greater with sad tears than with the trickled saline (-28.6±3.3% vs. -14.0±5.2%; P = 0.019). These data suggest that chemosignals from human sad tears and postprandial plasma do not appear to reduce appetite and food intake. However, further studies are necessary to examine whether sad tears may alter the appetite-eating behavior relation.

  15. Determination of the total drug-related chlorine and bromine contents in human blood plasma using high performance liquid chromatography-tandem ICP-mass spectrometry (HPLC-ICP-MS/MS).

    PubMed

    Klencsár, Balázs; Bolea-Fernandez, Eduardo; Flórez, María R; Balcaen, Lieve; Cuyckens, Filip; Lynen, Frederic; Vanhaecke, Frank

    2016-05-30

    A fast, accurate and precise method for the separation and determination of the total contents of drug-related Cl and Br in human blood plasma, based on high performance liquid chromatography - inductively coupled plasma - tandem mass spectrometry (HPLC-ICP-MS/MS), has been developed. The novel approach was proved to be a suitable alternative to the presently used standard methodology (i.e. based on a radiolabelled version of the drug molecule and radiodetection), while eliminating the disadvantages of the latter. Interference-free determination of (35)Cl has been accomplished via ICP-MS/MS using H2 as reaction gas and monitoring the (35)ClH2(+) reaction product at mass-to-charge ratio of 37. Br could be measured "on mass" at a mass-to-charge of 79. HPLC was relied on for the separation of the drug-related entities from the substantial amount of inorganic Cl. The method developed was found to be sufficiently precise (repeatability <10% RSD) and accurate (recovery between 95 and 105%) and shows a linear dynamic range (R(2)>0.990) from the limit of quantification (0.05 and 0.01 mg/L for Cl and Br in blood plasma, respectively) to at least 5 and 1mg/L for Cl and Br, respectively. Quantification via either external or internal standard calibration provides reliable results for both elements. As a proof-of-concept, human blood plasma samples from a clinical study involving a newly developed Cl- and Br-containing active pharmaceutical ingredient were analysed and the total drug exposure was successfully described. Cross-validation was achieved by comparing the results obtained on Cl- and on Br-basis. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. β-actin as a loading control for plasma-based Western blot analysis of major depressive disorder patients.

    PubMed

    Zhang, Rufang; Yang, Deyu; Zhou, Chanjuan; Cheng, Ke; Liu, Zhao; Chen, Liang; Fang, Liang; Xie, Peng

    2012-08-15

    Western blot analysis is a commonly used technique for determining specific protein levels in clinical samples. For normalization of protein levels in Western blot, a suitable loading control is required. On account of its relatively high and constant expression, β-actin has been widely employed in Western blot of cell cultures and tissue extracts. However, β-actin's presence in human plasma and this protein's putative role as a plasma-based loading control for Western blot analysis remain unknown. In this study, an enzyme-linked immunosorbent assay was used to determine the concentration of β-actin in human plasma, which is 6.29±0.54 ng/ml. In addition, the linearity of β-actin immunostaining and loaded protein amount was evaluated by Western blot, and a fine linearity (R²=0.974±0.012) was observed. Furthermore, the expression of plasma β-actin in major depressive disorder subjects and healthy controls was compared. The data revealed no statistically significant difference between these two groups. Moreover, the total coefficient of variation for β-actin expression in the two groups was 9.2±1.2%. These findings demonstrate that β-actin is present in human plasma and may possibly be used as a suitable loading control for plasma-based Western blot analysis in major depressive disorder. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    PubMed Central

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  18. Antitumorigenic effect of atmospheric-pressure dielectric barrier discharge on human colorectal cancer cells via regulation of Sp1 transcription factor

    NASA Astrophysics Data System (ADS)

    Han, Duksun; Cho, Jin Hyoung; Lee, Ra Ham; Bang, Woong; Park, Kyungho; Kim, Minseok S.; Shim, Jung-Hyun; Chae, Jung-Il; Moon, Se Youn

    2017-02-01

    Human colorectal cancer cell lines (HT29 and HCT116) were exposed to dielectric barrier discharge (DBD) plasma at atmospheric pressure to investigate the anticancer capacity of the plasma. The dose- and time-dependent effects of DBDP on cell viability, regulation of transcription factor Sp1, cell-cycle analysis, and colony formation were investigated by means of MTS assay, DAPI staining, propidium iodide staining, annexin V-FITC staining, Western blot analysis, RT-PCR analysis, fluorescence microscopy, and anchorage-independent cell transformation assay. By increasing the duration of plasma dose times, significant reductions in the levels of both Sp1 protein and Sp1 mRNA were observed in both cell lines. Also, expression of negative regulators related to the cell cycle (such as p53, p21, and p27) was increased and of the positive regulator cyclin D1 was decreased, indicating that the plasma treatment led to apoptosis and cell-cycle arrest. In addition, the sizes and quantities of colony formation were significantly suppressed even though two cancer promoters, such as TPA and epidermal growth factor, accompanied the plasma treatment. Thus, plasma treatment inhibited cell viability and colony formation by suppressing Sp1, which induced apoptosis and cell-cycle arrest in these two human colorectal cancer cell lines.

  19. Ultrasound-assisted combined with nano-sized molecularly imprinted polymer for selective extraction and pre-concentration of amitriptyline in human plasma with gas chromatography-flame detection.

    PubMed

    Khanahmadzadeh, Salah; Tarigh, Ahmad

    2014-12-01

    A new process was developed for the selective extraction and pre-concentration of amitriptyline (AT) from human plasma using nano-sized molecularly imprinted polymer (MIP) with ultrasound-assisted extraction (UAE). The nano-sized AT imprinted polymer particles were synthesized using suspension polymerization in silicon oil and characterized by Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscope (SEM) methods. With the application of optimized values, linearity values in the ranges of 20-200μgmL(-1) and 35-200μgmL(-1) were obtained for AT with the correlation of determination values (r(2)) 0.998 and 0.995 in water and plasma, respectively. The limits of detections (S/N=3) for AT were found to be 0.7 and 1.2μgmL(-1) in water and plasma, respectively. The enrichment factors of AT in water and plasma were 52 and 40, respectively. The inter-day precisions (%) were in the range of 5.8-9.2%. Relative recovery rates ranged from 82.4% to 92.3%. The method was successfully applied to determine AT in the human plasma samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. The clearance of /sup 131/I-human plasma ferritin in man

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worwood, M.; Cragg, S.J.; Williams, A.M.

    1982-10-01

    Ferritin was purified 33,000-fold from the plasma of patients with idiopathic hemochromatosis. The plasma ferritin was labeled with /sup 131/I and injected into 2 normal men. Clearance was found to be relatively slow, with 50% /sup 131/I-ferritin remaining in the plasma at 27-30 hr. The fraction of plasma ferritin that bound to concanavalin-A was found to be cleared more slowly than the nonbinding fraction. These findings confirm our previous suggestion that glycosylation is a major factor prolonging the survival of ferritin in the plasma, but differ from the results of earlier studies in experimental animals and preterm infants, which indicatedmore » very rapid plasma ferritin turnover.« less

  1. Microdevice for plasma separation from whole human blood using bio-physical and geometrical effects

    NASA Astrophysics Data System (ADS)

    Tripathi, Siddhartha; Kumar, Y. V. Balavarun; Agrawal, Amit; Prabhakar, Amit; Joshi, Suhas S.

    2016-06-01

    In this research work, we present a simple and efficient passive microfluidic device for plasma separation from pure blood. The microdevice has been fabricated using conventional photolithography technique on a single layer of polydimethylsiloxane, and has been extensively tested on whole blood and enhanced (upto 62%) hematocrit levels of human blood. The microdevice employs elevated dimensions of about 100 μm such elevated dimensions ensure clog-free operation of the microdevice and is relatively easy to fabricate. We show that our microdevice achieves almost 100% separation efficiency on undiluted blood in the flow rate range of 0.3 to 0.5 ml/min. Detailed biological characterization of the plasma obtained from the microdevice is carried out by testing: proteins by ultra-violet spectrophotometric method, hCG (human chorionic gonadotropin) hormone, and conducting random blood glucose test. Additionally, flow cytometry study has also been carried on the separated plasma. These tests attest to the high quality of plasma recovered. The microdevice developed in this work is an outcome of extensive experimental research on understanding the flow behavior and separation phenomenon of blood in microchannels. The microdevice is compact, economical and effective, and is particularly suited in continuous flow operations.

  2. Rapid determination of tafenoquine in small volume human plasma samples by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Doyle, E; Fowles, S E; Summerfield, S; White, T J

    2002-03-25

    A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.

  3. Application of a novel large-volume injection method using a stomach-shaped inlet liner in capillary gas chromatographic trace analysis of dioxins in human milk and plasma.

    PubMed

    Saito, Koichi; Ohmura, Atsuko; Takekuma, Mikiko; Sasano, Ryoichi; Matsuki, Yasuhiko; Nakazawa, Hiroyuki

    2007-06-01

    A newly developed large-volume injection (LVI) technique that employs a unique stomach-shaped inlet liner (SSIL) inside of a programmable temperature vaporizer was used for the determination of trace amounts of dioxins in human milk and plasma. The initial temperature and the initial dwelling time of the inlet and the kind of solvent used were found to be critical in determining the analytical sensitivity of dioxins due to the loss of these relatively volatile compounds during solvent vaporization. Human milk and plasma were purified and fractionated by pre-packed multi-layered silica-gel chromatography and activated carbon silica-gel column chromatography. A 20-microL aliquot of the fraction collected from the chromatography with toluene was directly applied to the LVI system in high-resolution gas chromatography/high-resolution mass spectrometry. Excellent correlation (r > 0.97) between the values obtained by the LVI method using the SSIL device and those by the conventional regular-volume splitless injection method was obtained for PCDDs, PCDFs and non-ortho PCBs in human milk and plasma samples.

  4. Liquid chromatography-tandem mass spectrometry method of loxoprofen in human plasma.

    PubMed

    Lee, Hye Won; Ji, Hye Young; Sohn, Dong Hwan; Kim, Se-Mi; Lee, Yong Bok; Lee, Hye Suk

    2009-07-01

    A rapid, sensitive and selective liquid chromatography-electrospray ionization mass spectrometric method for the determination of loxoprofen in human plasma was developed. Loxoprofen and ketoprofen (internal standard) were extracted from 20 microL of human plasma sample using ethyl acetate at acidic pH and analyzed on an Atlantis dC(18) column with the mobile phase of methanol:water (75:25, v/v). The analytes were quantified in the selected reaction monitoring mode. The standard curve was linear over the concentration range of 0.1-20 microg/mL with a lower limit of quantification of 0.1 microg/mL. The coefficient of variation and relative error for intra- and inter-assay at four quality control levels were 2.8-5.2 and 4.8-7.0%, respectively. The recoveries of loxoprofen and ketoprofen were 69.7 and 67.6%, respectively. The matrix effects for loxoprofen and ketoprofen were practically absent. This method was successfully applied to the pharmacokinetic study of loxoprofen in humans. (c) 2009 John Wiley & Sons, Ltd.

  5. Reactive fluxes delivered by dielectric barrier discharge filaments to slightly wounded skin

    NASA Astrophysics Data System (ADS)

    Babaeva, Natalia Yu; Kushner, Mark J.

    2013-01-01

    The application of atmospheric-pressure plasmas to human tissue has been shown to have therapeutic effects for wound healing and in treatment of skin diseases. In this paper, we report on a computational study of the intersection of plasma filaments in a dielectric barrier discharge (DBD) with a small wound in human skin in the context of plasma medicine. The wound is represented as a small cut in the epidermal layer of cells. Intracellular structures and their electrical properties were incorporated into the two-dimensional computational mesh in order to self-consistently couple gas phase plasma transport with the charging of the surface of the wound. We quantify the fluxes of reactive oxygen and nitrogen species, ions and photons produced in or diffusing into the wound as might occur during the first few discharge pulses of treatment. Comparison is made to fluxes predicted by global modelling. We show that the relative location of the plasma filament with respect to the wound is important on plasma time scales (ns) for ions and photons, and for radicals directly produced by electron impact processes. On the longer-term diffusion time scales (ms) the position of the plasma filament relative to the wound is not so critical. For typical DBD conditions, the magnitude of these fluxes to the cellular surfaces corresponds to fluences of radicals nearly equal to the surface site density. These results imply that the biological reactivity is limited by reaction probabilities and not the availability of radical fluxes.

  6. Human milk insulin is related to maternal plasma insulin and BMI: but other components of human milk do not differ by BMI.

    PubMed

    Young, B E; Patinkin, Z; Palmer, C; de la Houssaye, B; Barbour, L A; Hernandez, T; Friedman, J E; Krebs, N F

    2017-09-01

    The impact of maternal BMI and insulin sensitivity on bioactive components of human milk (HM) is not well understood. As the prevalence of obesity and diabetes rises, it is increasingly critical that we understand how maternal BMI and hormones associated with metabolic disease relate to concentrations of bioactive components in HM. This longitudinal cohort design followed 48 breastfeeding mothers through the first four months of lactation, collecting fasting morning HM samples at 2-weeks and 1, 2, 3 and 4-months, and fasting maternal blood at 2-weeks and 4-months. Insulin, glucose, adipokines leptin and adiponectin, appetite regulating hormone ghrelin, marker of oxidative stress 8OHdG and inflammatory cytokines (IL-6, IL-8, and TNF-a) were measured in HM and maternal plasma. A total of 26 normal weight (NW) (BMI=21.4±2.0 kg/m 2 ) and 22 overweight/obese (OW/Ob) (BMI=30.4±4.2 kg/m 2 ) were followed. Of all HM analytes measured, only insulin and leptin were different between groups - consistently higher in the OW/Ob group (leptin: P<0.001; insulin: P<0.03). HM insulin was 98% higher than maternal plasma insulin at 2-weeks and 32% higher at 4-months (P<0.001). Maternal fasting plasma insulin and HOMA-IR were positively related to HM insulin at 2-weeks (P<0.001, R 2 ⩾0.38, n=31), and 4-months (P⩽0.005, R 2 ⩾0.20, n=38). The concentrations of insulin in HM are higher than in maternal plasma and are related to maternal BMI and insulin sensitivity. With the exception of leptin, there were minimal other differences observed in HM composition across a wide range in maternal BMI.

  7. A fully validated method for the determination of lacosamide in human plasma using gas chromatography with mass spectrometry: application for therapeutic drug monitoring.

    PubMed

    Nikolaou, Panagiota; Papoutsis, Ioannis; Spiliopoulou, Chara; Voudris, Constantinos; Athanaselis, Sotiris

    2015-01-01

    A simple gas chromatographic method with mass spectrometry detection was developed and validated for the determination of lacosamide in human plasma. Lacosamide and the internal standard, levetiracetam-d6, were extracted from 200 μL plasma, by a solid-phase extraction through HF Bond Elut C18 columns, and derivatized using N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide with 1% tert-butyldimethylsilylchloride in acetonitrile. The limit of quantification was found to be 0.20 μg/mL and the assay was linear up to 20.0 μg/mL with correlation coefficient ≥0.994. The intra- and interday precision values were <4.1% in terms of relative standard deviation (%) and the values of intra- and interday accuracy were found to be within -7.2 and 5.3% in terms of relative error (%). Absolute recovery of the method for lacosamide was determined at three concentration levels and ranged from 92.5 to 97.6%. The developed method uses small volumes of plasma and proved to be simple, rapid, and sensitive for the determination of lacosamide in plasma. This method can be used in routine every day analysis of plasma samples obtained from patients who follow respective antiepileptic treatment and for the investigation of clinical and forensic cases where lacosamide is involved. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Plasma exosome microRNAs are indicative of breast cancer.

    PubMed

    Hannafon, Bethany N; Trigoso, Yvonne D; Calloway, Cameron L; Zhao, Y Daniel; Lum, David H; Welm, Alana L; Zhao, Zhizhuang J; Blick, Kenneth E; Dooley, William C; Ding, W Q

    2016-09-08

    microRNAs are promising candidate breast cancer biomarkers due to their cancer-specific expression profiles. However, efforts to develop circulating breast cancer biomarkers are challenged by the heterogeneity of microRNAs in the blood. To overcome this challenge, we aimed to develop a molecular profile of microRNAs specifically secreted from breast cancer cells. Our first step towards this direction relates to capturing and analyzing the contents of exosomes, which are small secretory vesicles that selectively encapsulate microRNAs indicative of their cell of origin. To our knowledge, circulating exosome microRNAs have not been well-evaluated as biomarkers for breast cancer diagnosis or monitoring. Exosomes were collected from the conditioned media of human breast cancer cell lines, mouse plasma of patient-derived orthotopic xenograft models (PDX), and human plasma samples. Exosomes were verified by electron microscopy, nanoparticle tracking analysis, and western blot. Cellular and exosome microRNAs from breast cancer cell lines were profiled by next-generation small RNA sequencing. Plasma exosome microRNA expression was analyzed by qRT-PCR analysis. Small RNA sequencing and qRT-PCR analysis showed that several microRNAs are selectively encapsulated or highly enriched in breast cancer exosomes. Importantly, the selectively enriched exosome microRNA, human miR-1246, was detected at significantly higher levels in exosomes isolated from PDX mouse plasma, indicating that tumor exosome microRNAs are released into the circulation and can serve as plasma biomarkers for breast cancer. This observation was extended to human plasma samples where miR-1246 and miR-21 were detected at significantly higher levels in the plasma exosomes of 16 patients with breast cancer as compared to the plasma exosomes of healthy control subjects. Receiver operating characteristic curve analysis indicated that the combination of plasma exosome miR-1246 and miR-21 is a better indicator of breast cancer than their individual levels. Our results demonstrate that certain microRNA species, such as miR-21 and miR-1246, are selectively enriched in human breast cancer exosomes and significantly elevated in the plasma of patients with breast cancer. These findings indicate a potential new strategy to selectively analyze plasma breast cancer microRNAs indicative of the presence of breast cancer.

  9. Metabolism of substance P and neurokinin A by human vascular endothelium and smooth muscle.

    PubMed

    Wang, L; Sadoun, E; Stephens, R E; Ward, P E

    1994-01-01

    Analysis of SP and NKA metabolism by human vascular endothelium, relative to that in human plasma, identified integrative, multiple pathways for the processing of circulating SP (but not NKA) by angiotensin-converting enzyme (ACE; EC 3.4.15.1), dipeptidyl(amino)peptidase IV (DAP IV; EC 3.4.14.5), and aminopeptidase M (AmM; EC 3.4.11.2). In contrast, SP and NKA, which may diffuse into or be neurally released within the vessel wall, were both metabolized by smooth muscle neutral endopeptidase-24.11 (NEP-24.11; EC 3.4.24.11). Collectively, these studies indicate peptide-specific and site-specific differential processing of SP and NKA by human plasma and vasculature.

  10. A Mouse to Human Search for Plasma Proteome Changes Associated with Pancreatic Tumor Development

    PubMed Central

    Faca, Vitor M; Song, Kenneth S; Wang, Hong; Zhang, Qing; Krasnoselsky, Alexei L; Newcomb, Lisa F; Plentz, Ruben R; Gurumurthy, Sushma; Redston, Mark S; Pitteri, Sharon J; Pereira-Faca, Sandra R; Ireton, Renee C; Katayama, Hiroyuki; Glukhova, Veronika; Phanstiel, Douglas; Brenner, Dean E; Anderson, Michelle A; Misek, David; Scholler, Nathalie; Urban, Nicole D; Barnett, Matt J; Edelstein, Cim; Goodman, Gary E; Thornquist, Mark D; McIntosh, Martin W; DePinho, Ronald A; Bardeesy, Nabeel; Hanash, Samir M

    2008-01-01

    Background The complexity and heterogeneity of the human plasma proteome have presented significant challenges in the identification of protein changes associated with tumor development. Refined genetically engineered mouse (GEM) models of human cancer have been shown to faithfully recapitulate the molecular, biological, and clinical features of human disease. Here, we sought to exploit the merits of a well-characterized GEM model of pancreatic cancer to determine whether proteomics technologies allow identification of protein changes associated with tumor development and whether such changes are relevant to human pancreatic cancer. Methods and Findings Plasma was sampled from mice at early and advanced stages of tumor development and from matched controls. Using a proteomic approach based on extensive protein fractionation, we confidently identified 1,442 proteins that were distributed across seven orders of magnitude of abundance in plasma. Analysis of proteins chosen on the basis of increased levels in plasma from tumor-bearing mice and corroborating protein or RNA expression in tissue documented concordance in the blood from 30 newly diagnosed patients with pancreatic cancer relative to 30 control specimens. A panel of five proteins selected on the basis of their increased level at an early stage of tumor development in the mouse was tested in a blinded study in 26 humans from the CARET (Carotene and Retinol Efficacy Trial) cohort. The panel discriminated pancreatic cancer cases from matched controls in blood specimens obtained between 7 and 13 mo prior to the development of symptoms and clinical diagnosis of pancreatic cancer. Conclusions Our findings indicate that GEM models of cancer, in combination with in-depth proteomic analysis, provide a useful strategy to identify candidate markers applicable to human cancer with potential utility for early detection. PMID:18547137

  11. 21 CFR 640.90 - Plasma Protein Fraction (Human).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Plasma Protein Fraction (Human). 640.90 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.90 Plasma Protein Fraction (Human). (a) Proper name and definition. The proper name of the product shall be...

  12. 21 CFR 640.90 - Plasma Protein Fraction (Human).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Plasma Protein Fraction (Human). 640.90 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.90 Plasma Protein Fraction (Human). (a) Proper name and definition. The proper name of the product shall be...

  13. 21 CFR 640.90 - Plasma Protein Fraction (Human).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Plasma Protein Fraction (Human). 640.90 Section 640...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.90 Plasma Protein Fraction (Human). (a) Proper name and definition. The proper name of the product shall be...

  14. 21 CFR 640.90 - Plasma Protein Fraction (Human).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Plasma Protein Fraction (Human). 640.90 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.90 Plasma Protein Fraction (Human). (a) Proper name and definition. The proper name of the product shall be...

  15. 21 CFR 640.90 - Plasma Protein Fraction (Human).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Plasma Protein Fraction (Human). 640.90 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.90 Plasma Protein Fraction (Human). (a) Proper name and definition. The proper name of the product shall be...

  16. Determination of cortisol in human plasma by thin-layer chromatography and fluorescence derivatization with isonicotinic acid hydrazide.

    PubMed

    Fenske, Martin

    2008-01-01

    The present work describes a specific and rapid determination of cortisol in human plasma. The method includes liquid-liquid extraction of plasma samples, thin-layer chromatography (TLC) of ethanolic extracts on aluminium foil-backed silica gel 60 TLC plates, derivatization of cortisol with isonicotinic acid hydrazide, and densitometric measurement of the fluorescence intensity of cortisol hydrazone. The fluorescence was linearly related to cortisol amounts; the correlation coefficients of standard curve plots were r>0.99. The coefficient of variation ranged between 2.8-7.9% (20 ng, within-assay/between assay variation) and 1.6-6.8% (80 ng, within-assay/between assay variation). The recovery of cortisol from plasma spiked with 21-deoxycortisol was 85%+/-4%. Cortisol concentration in the plasma was 66+/-32 ng/mL (mean+/-standard deviation, n=24). The advantage of this method is its simplicity to separate cortisol from other steroids by TLC, its specificity (formation of cortisol hydrazone), and the rapid quantitation of cortisol by densitometry.

  17. Human skeletal muscle ascorbate is highly responsive to changes in vitamin C intake and plasma concentrations123

    PubMed Central

    Bozonet, Stephanie M; Pullar, Juliet M; Simcock, Jeremy W; Vissers, Margreet CM

    2013-01-01

    Background: Vitamin C (ascorbate) is likely to be essential for skeletal muscle structure and function via its role as an enzyme cofactor for collagen and carnitine biosynthesis. Vitamin C may also protect these metabolically active cells from oxidative stress. Objective: We investigated the bioavailability of vitamin C to human skeletal muscle in relation to dietary intake and plasma concentrations and compared this relation with ascorbate uptake by leukocytes. Design: Thirty-six nonsmoking men were randomly assigned to receive 6 wk of 0.5 or 2 kiwifruit/d, an outstanding dietary source of vitamin C. Fasting blood samples were drawn weekly, and 24-h urine and leukocyte samples were collected before intervention, after intervention, and after washout. Needle biopsies of skeletal muscle (vastus lateralis) were carried out before and after intervention. Results: Baseline vastus lateralis ascorbate concentrations were ∼16 nmol/g tissue. After intervention with 0.5 or 2 kiwifruit/d, these concentrations increased ∼3.5-fold to 53 and 61 nmol/g, respectively. There was no significant difference between the responses of the 2 groups. Mononuclear cell and neutrophil ascorbate concentrations increased only ∼1.5- and ∼2-fold, respectively. Muscle ascorbate concentrations were highly correlated (P < 0.001) with dietary intake (R = 0.61) and plasma concentrations (R = 0.75) in the range from 5 to 80 μmol/L. Conclusions: Human skeletal muscle is highly responsive to vitamin C intake and plasma concentrations and exhibits a greater relative uptake of ascorbate than leukocytes. Thus, muscle appears to comprise a relatively labile pool of ascorbate and is likely to be prone to ascorbate depletion with inadequate dietary intake. This trial was registered at the Australian New Zealand Clinical Trials Registry (www.anzctr.org.au) as ACTRN12611000162910. PMID:23446899

  18. Human skeletal muscle ascorbate is highly responsive to changes in vitamin C intake and plasma concentrations.

    PubMed

    Carr, Anitra C; Bozonet, Stephanie M; Pullar, Juliet M; Simcock, Jeremy W; Vissers, Margreet Cm

    2013-04-01

    Vitamin C (ascorbate) is likely to be essential for skeletal muscle structure and function via its role as an enzyme cofactor for collagen and carnitine biosynthesis. Vitamin C may also protect these metabolically active cells from oxidative stress. We investigated the bioavailability of vitamin C to human skeletal muscle in relation to dietary intake and plasma concentrations and compared this relation with ascorbate uptake by leukocytes. Thirty-six nonsmoking men were randomly assigned to receive 6 wk of 0.5 or 2 kiwifruit/d, an outstanding dietary source of vitamin C. Fasting blood samples were drawn weekly, and 24-h urine and leukocyte samples were collected before intervention, after intervention, and after washout. Needle biopsies of skeletal muscle (vastus lateralis) were carried out before and after intervention. Baseline vastus lateralis ascorbate concentrations were ~16 nmol/g tissue. After intervention with 0.5 or 2 kiwifruit/d, these concentrations increased ~3.5-fold to 53 and 61 nmol/g, respectively. There was no significant difference between the responses of the 2 groups. Mononuclear cell and neutrophil ascorbate concentrations increased only ~1.5- and ~2-fold, respectively. Muscle ascorbate concentrations were highly correlated (P < 0.001) with dietary intake (R = 0.61) and plasma concentrations (R = 0.75) in the range from 5 to 80 μmol/L. Human skeletal muscle is highly responsive to vitamin C intake and plasma concentrations and exhibits a greater relative uptake of ascorbate than leukocytes. Thus, muscle appears to comprise a relatively labile pool of ascorbate and is likely to be prone to ascorbate depletion with inadequate dietary intake. This trial was registered at the Australian New Zealand Clinical Trials Registry (www.anzctr.org.au) as ACTRN12611000162910.

  19. Analysis of 6-mercaptopurine in human plasma with a high-performance liquid chromatographic method including post-column derivatization and fluorimetric detection.

    PubMed

    Jonkers, R E; Oosterhuis, B; ten Berge, R J; van Boxtel, C J

    1982-12-10

    A relatively simple assay with improved reliability and sensitivity for measuring levels of 6-mercaptopurine in human plasma is presented. After extraction of the compound and the added internal standard with phenyl mercury acetate, samples were separated by ion-pair reversed-phase high-performance liquid chromatography. On-line the analytes were oxidized to fluorescent products and detected in a flow-fluorimeter. The within-day coefficient of variation was 3.8% at a concentration of 25 ng/ml. The lower detection limit was 2 ng/ml when 1.0 ml of plasma was used. Mercaptopurine concentration versus time curves of two subjects after a single oral dose of azathioprine are shown.

  20. Simultaneous determination of acetaminophen and dihydrocodeine in human plasma by UPLC-MS/MS: Its pharmacokinetic application.

    PubMed

    Qiu, Xiangjun; Lou, Dan; Su, Ding; Liu, Zebin; Gao, Pengtao; Zhang, Nan-sheng

    2015-06-15

    An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Benzodiazepine sensitivity in normal human subjects.

    PubMed

    Hommer, D W; Matsuo, V; Wolkowitz, O; Chrousos, G; Greenblatt, D J; Weingartner, H; Paul, S M

    1986-06-01

    Increasing intravenous doses of diazepam or placebo were administered to ten healthy normal volunteers, and the changes in saccadic eye velocity, self-rated sedation and anxiety, and plasma cortisol and growth hormone concentrations were measured. Diazepam administration (4.4 to 140 micrograms/kg, cumulative dose) resulted in a dose-dependent decrease in saccadic eye velocity and plasma cortisol level as well as a dose-dependent increase in self-rated sedation and plasma growth hormone level. Self-rated anxiety was unaffected in these relatively nonanxious subjects. The diazepam-induced changes in saccadic eye velocity, sedation, and growth hormone and cortisol levels were highly correlated with each other and with increasing plasma diazepam concentration. These results are consistent with a benzodiazepine receptor-mediated action of diazepam. The highly quantifiable and dose-dependent decrease in saccadic eye velocity by benzodiazepines should make this a useful measure of benzodiazepine receptor sensitivity in humans.

  2. Characterization of a plasma membrane-associated prenylcysteine-directed alpha carboxyl methyltransferase in human neutrophils.

    PubMed

    Pillinger, M H; Volker, C; Stock, J B; Weissmann, G; Philips, M R

    1994-01-14

    Signal transduction in human neutrophils requires prenylcysteine-directed carboxyl methylation of ras-related low molecular weight GTP-binding proteins. We now report the subcellular localization and characterization of a neutrophil prenylcysteine alpha carboxyl methyltransferase. The highest carboxyl methyltransferase activity copurified with biotinylated neutrophil surface membranes, supporting a plasma membrane localization of the enzyme. Neutrophil nuclear fractions contained little or no methyltransferase activity. Methyltransferase activity was detergent-sensitive but could be reconstituted by removal of detergent in the presence of phosphatidyl choline and an anionic phospholipid. N-Acetyl-S-trans,trans-farnesyl-L-cysteine (AFC) and N-acetyl-S-all-trans-geranylgeranyl-L-cysteine (AGGC) were effective substrates for neutrophil prenylcysteine-directed methyltransferase; Vmax values for AFC and AGGC (16.4 and 22.1 pmol of methylated/mg protein/min, respectively) are among the highest yet reported. Although both GTP gamma S and the chemoattractant fMet-Leu-Phe stimulated methylation of ras-related proteins, neither affected methylation of AFC. These data suggest that neutrophil plasma membranes contain a phospholipid-dependent, prenylcysteine-directed carboxyl methyltransferase of relatively high specific activity that modifies ras-related protein substrates in the GTP-bound, activated state.

  3. Determination of Flurbiprofen in Human Plasma by High-Performance Liquid Chromatography.

    PubMed

    Yilmaz, Bilal; Erdem, Ali Fuat

    2015-10-01

    A simple high-performance liquid chromatography method has been developed for determination of flurbiprofen in human plasma. The method was validated on an Ace C18 column using UV detection. The mobile phase was acetonitrile-0.05 M potassium dihydrogen phosphate solution (60:40, v/v) adjusted to pH 3.5 with phosphoric acid. The calibration curve was linear between the concentration range of 0.10-5.0 μg/mL. Intra- and inter-day precision values for flurbiprofen in plasma were <4.47, and accuracy (relative error) was better than 3.67%. The extraction recoveries of flurbiprofen from human plasma were between 93.0 and 98.9%. The limits of detection and quantification of flurbiprofen were 0.03 and 0.10 μg/mL, respectively. In addition, this assay was applied to determine the pharmacokinetic parameters of flurbiprofen in six healthy Turkish volunteers who had been given 100 mg flurbiprofen. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Plasma NOV/CCN3 Levels Are Closely Associated with Obesity in Patients with Metabolic Disorders

    PubMed Central

    Pakradouni, Jihane; Le Goff, Wilfried; Calmel, Claire; Antoine, Bénédicte; Villard, Elise; Frisdal, Eric; Abifadel, Marianne; Tordjman, Joan; Poitou, Christine; Bonnefont-Rousselot, Dominique; Bittar, Randa; Bruckert, Eric; Clément, Karine; Fève, Bruno; Martinerie, Cécile; Guérin, Maryse

    2013-01-01

    Objective Evidence points to a founder of the multifunctional CCN family, NOV/CCN3, as a circulating molecule involved in cardiac development, vascular homeostasis and inflammation. No data are available on the relationship between plasma NOV/CCN3 levels and cardiovascular risk factors in humans. This study investigated the possible relationship between plasma NOV levels and cardiovascular risk factors in humans. Methods NOV levels were measured in the plasma from 594 adults with a hyperlipidemia history and/or with lipid-lowering therapy and/or a body mass index (BMI) >30 kg/m2. Correlations were measured between NOV plasma levels and various parameters, including BMI, fat mass, and plasma triglycerides, cholesterol, glucose, and C-reactive protein. NOV expression was also evaluated in adipose tissue from obese patients and rodents and in primary cultures of adipocytes and macrophages. Results After full multivariate adjustment, we detected a strong positive correlation between plasma NOV and BMI (r = 0.36 p<0.0001) and fat mass (r = 0.33 p<0.0005). According to quintiles, this relationship appeared to be linear. NOV levels were also positively correlated with C-reactive protein but not with total cholesterol, LDL-C or blood glucose. In patients with drastic weight loss induced by Roux-en-Y bariatric surgery, circulating NOV levels decreased by 28% (p<0.02) and 48% (p<0.0001) after 3 and 6 months, respectively, following surgery. In adipose tissue from obese patients, and in human primary cultures NOV protein was detected in adipocytes and macrophages. In mice fed a high fat diet NOV plasma levels and its expression in adipose tissue were also significantly increased compared to controls fed a standard diet. Conclusion Our results strongly suggest that in obese humans and mice plasma NOV levels positively correlated with NOV expression in adipose tissue, and support a possible contribution of NOV to obesity-related inflammation. PMID:23785511

  5. Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

    PubMed Central

    Fazeli-Bakhtiyari, Rana; Panahi-Azar, Vahid; Sorouraddin, Mohammad Hossein; Jouyban, Abolghasem

    2015-01-01

    Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. Results: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. Conclusion: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. PMID:26730332

  6. Sensitive parenting is associated with plasma oxytocin and polymorphisms in the OXTR and CD38 genes.

    PubMed

    Feldman, Ruth; Zagoory-Sharon, Orna; Weisman, Omri; Schneiderman, Inna; Gordon, Ilanit; Maoz, Rina; Shalev, Idan; Ebstein, Richard P

    2012-08-01

    Research in mammals has demonstrated the involvement of oxytocin (OT) in social bond formation; yet, its role in human bonding remains unclear. Plasma OT has been used as a proxy for central activity and studies indicate its association with human affiliative behaviors. Molecular genetic studies also reveal a role for OT neuropathways in shaping the social brain. However, the links between peripheral OT, genetic markers, and their combined contribution to human parenting are unknown. Participants included 352 individuals: 272 mothers and fathers and their 4- to 6-month-old-infants and 80 nonparents. Plasma OT was assayed from adults who were genotyped for oxytocin receptor (OXTR) and CD38 risk alleles associated with social dysfunctions. CD38 is an ectoenzyme that mediates the release of brain OT. Parent-infant interactions were microcoded for parental touch and gaze synchrony and participants reported on parental care in childhood. OXTR (rs2254298 and rs1042778) and CD38 (rs3796863) risk alleles were each associated with lower plasma OT. Reduced plasma OT and both OXTR and CD38 risk alleles were related to less parental touch. The interaction of high plasma OT and low-risk CD38 alleles predicted longer durations of parent-infant gaze synchrony. Parents reporting greater parental care showed higher plasma OT, low-risk CD38 alleles, and more touch toward their infants. Results indicate that peripheral and genetic markers of the extended OT pathway are interrelated and underpin core behaviors associated with human parenting and social engagement. These findings may have important implications for understanding neuropsychiatric disorders marked by early social dysfunctions. Copyright © 2012 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  7. [Determination of plasma protein binding rate of arctiin and arctigenin with ultrafiltration].

    PubMed

    Han, Xue-Ying; Wang, Wei; Tan, Ri-Qiu; Dou, De-Qiang

    2013-02-01

    To determine the plasma protein binding rate of arctiin and arctigenin. The ultrafiltration combined with HPLC was employed to determine the plasma protein binding rate of arctiin and arctigenin as well as rat plasma and healthy human plasma proteins. The plasma protein binding rate of arctiin with rat plasma at the concentrations of 64. 29, 32.14, 16.07 mg x L(-1) were (71.2 +/- 2.0)%, (73.4 +/- 0.61)%, (78.2 +/- 1.9)%, respectively; while the plasma protein binding rate of arctiin with healthy human plasma at the above concentrations were (64.8 +/- 3.1)%, (64.5 +/- 2.5)%, (77.5 +/- 1.7)%, respectively. The plasma protein binding rate of arctigenin with rat plasma at the concentrations of 77.42, 38.71, 19.36 mg x L(-1) were (96.7 +/- 0.41)%, (96.8 +/- 1.6)%, (97.3 +/- 0.46)%, respectively; while the plasma protein binding rate of arctigenin with normal human plasma at the above concentrations were (94.7 +/- 3.1)%, (96.8 +/- 1.6)%, (97.9 +/- 1.3)%, respectively. The binding rate of arctiin with rat plasma protein was moderate, which is slightly higher than the binding rate of arctiin with healthy human plasma protein. The plasma protein binding rates of arctigenin with both rat plasma and healthy human plasma are very high.

  8. THE CELLULAR ORIGIN OF HUMAN IMMUNOGLOBULINS (γ2, γ1M, γ1A)

    PubMed Central

    Mellors, Robert C.; Korngold, Leonhard

    1963-01-01

    A study was made of the cellular origin of human immunoglobulins (γ2, γ1M, γ1A). The results indicated that two closely related families of cells form immunoglobulins in human lymphoid tissue: germinal (reticular) centers and plasma cells. Thus their cellular origin in addition to their known antigenic relations further justifies placing the immunoglobulins in one family of proteins. Immunoglobulins were also formed to a small extent in primitive reticular cells which resembled those of germinal centers but were separated from them. Possibly such cells were undergoing transition to the much more numerous plasma cells with which they were commonly associated. The mantles of small lymphocytes which surrounded germinal centers did not contain detectable quantities of immunoglobulins. While in general only one type of immunoglobulin was present in an individual cell or germinal center, γ2- and γ1M-globulin were identified on occasion in the same plasma cell and germinal center. A peculiarity of the fetal thymus gland was the presence of immunoglobulin, mainly γ1M, in a small number of cells of small and intermediate size and primitive reticular appearance and in Hassall's corpuscles. PMID:14077999

  9. Determination of vigabatrin in human plasma and urine by high-performance liquid chromatography with UV-Vis detection.

    PubMed

    Cetin, Sevil Müge; Atmaca, Sedef

    2004-03-26

    A simple and reliable high-performance liquid chromatographic (HPLC) method with UV-Vis detection has been developed and validated for the determination of vigabatrin (VG) in human plasma and urine. The samples were pre-column derivatizated with 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS). A good chromatographic separation was achieved on a C18 column with a mobile phase consisting of acetonitrile and 10 mM orthophosphoric acid (pH 2.5) gradient elution. Tranexamic acid was used as an internal standard (I.S.). The method was linear over the concentration range of 0.8-30.0 microg/ml for both samples. The method is precise (relative standard deviation (R.S.D.) <9.13%) and accurate (relative mean error (RME) <-8.75%); analytical recoveries were 81.07% for plasma and 83.05% for urine. The assay was applied to pharmacokinetic study in a healthy volunteer after a single oral administration of 1 g of vigabatrin.

  10. Duodenal L cell density correlates with features of metabolic syndrome and plasma metabolites.

    PubMed

    van Baar, Annieke C G; Prodan, Andrei; Wahlgren, Camilla D; Poulsen, Steen S; Knop, Filip K; Groen, Albert K; Bergman, Jacques J; Nieuwdorp, Max; Levin, Evgeni

    2018-05-01

    Enteroendocrine cells are essential for the regulation of glucose metabolism, but it is unknown whether they are associated with clinical features of metabolic syndrome (MetS) and fasting plasma metabolites. We aimed to identify fasting plasma metabolites that associate with duodenal L cell, K cell and delta cell densities in subjects with MetS with ranging levels of insulin resistance. In this cross-sectional study, we evaluated L, K and delta cell density in duodenal biopsies from treatment-naïve males with MetS using machine-learning methodology. We identified specific clinical biomarkers and plasma metabolites associated with L cell and delta cell density. L cell density was associated with increased plasma metabolite levels including symmetrical dimethylarginine, 3-aminoisobutyric acid, kynurenine and glycine. In turn, these L cell-linked fasting plasma metabolites correlated with clinical features of MetS. Our results indicate a link between duodenal L cells, plasma metabolites and clinical characteristics of MetS. We conclude that duodenal L cells associate with plasma metabolites that have been implicated in human glucose metabolism homeostasis. Disentangling the causal relation between L cells and these metabolites might help to improve the (small intestinal-driven) pathophysiology behind insulin resistance in human obesity. © 2018 The authors.

  11. Effects of prolonged physical exercise and fasting upon plasma testosterone level in rats.

    PubMed

    Guezennec, C Y; Ferre, P; Serrurier, B; Merino, D; Pesquies, P C

    1982-01-01

    Prolonged physical exercise and fasting in male rats were studied to determine the effect of these two treatments on plasma testosterone level. Blood and tissue samples were drawn after 1 h, 3 h, 5 h, and 7 h treadmill running, and after 24 h, 48 h, and 72 h of fasting. Both treatments resulted in a significant fall in plasma testosterone, plasma luteinizing hormone (LH), plasma Insulin (IRI) and in liver and muscle glycogen stores. In the course of these two treatments the injection of a supra maximal dose of Human Chorionic Gonadotropin (HCG) produced a rise in plasma testosterone similar to that in control rats. This indicates that the decrease of plasma LH may be responsible for the decrease in plasma testosterone, which is time-related with the decrease in glycogen stores. The possible metabolic role of the decrease in plasma testosterone is discussed.

  12. Role of ceruloplasmin in nitric oxide metabolism in plasma of humans and sheep: a comparison of adults and fetuses

    PubMed Central

    Vrancken, Kurt; Schroeder, Hobe J.; Longo, Lawrence D.; Power, Gordon G.

    2013-01-01

    Nitric oxide (NO) is metabolized in plasma, in part by the ferroxidase ceruloplasmin (Cp), to form nitrite and nitrosothiols (SNOs), which are proposed to mediate protective responses to hypoxia and ischemia. We hypothesized that NO metabolism would be attenuated in fetal plasma due to low Cp activity. We measured Cp concentrations and activity in plasma samples collected from adults and fetuses of humans and sheep. We then added NO ([NO]: 1.5 or 100 μM) to plasma and aqueous buffer and measured rates of NO disappearance and the production of nitrite and SNO. Cp concentrations in fetal plasma were <15% of adult levels. In aqueous buffer, 1.5 μM NO disappeared with a half-life of 347 ± 64 s (means ± SE) but in plasma of humans the half-life was 19 ± 2 s (adult) and 11 ± 1 s (fetus, P = 0.004) and in sheep it was 31 ± 3 s (adult) and 43 ± 5 s (fetus, P = 0.04). Cp activity was not correlated with the overall elimination half-life of NO or with the amount of SNO ([NO]: 100 μM) or nitrite ([NO]: 1.5 or 100 μM) produced but correlated with SNO yields at 1.5 μM [NO] (r = 0.92, P = 0.04). Our data demonstrate that Cp is not essential to the increased rate of metabolism of NO in plasma relative to aqueous buffers and that it is not essential to the production of nitrite from NO. Cp may be involved in the conversion of NO to SNO in plasma under near-physiological concentrations of NO. PMID:24089378

  13. Human liver plasma membranes contain receptors for the hepatitis B virus pre-S1 region and, via polymerized human serum albumin, for the pre-S2 region.

    PubMed Central

    Pontisso, P; Petit, M A; Bankowski, M J; Peeples, M E

    1989-01-01

    Hepatitis B virus particles contain three related viral envelope proteins, the small, middle, and large S (surface) proteins. All three proteins contain the small S amino acid sequence at their carboxyl terminus. It is not clear which of these S proteins functions as the viral attachment protein, binding to a target cell receptor and initiating infection. In this report, recombinant hepatitis B surface antigen (rHBsAg) particles, which contain only virus envelope proteins, were radioactively labeled, and their attachment to human liver membranes was examined. Only the rHBsAg particles containing the large S protein were capable of directly attaching to liver plasma membranes. The attachment was saturable and could be prevented by competition with unlabeled particles or by a monoclonal antibody specific for the large S protein. In the presence of polymerized human serum albumin, both large and middle S protein-containing rHBsAg particles were capable of attaching to the liver plasma membranes. Small S protein-containing rHBsAg particles were not able to attach even in the presence of polymerized human serum albumin. These results indicate that the large S protein may be the viral attachment protein for hepatocytes, binding directly to liver plasma membranes by its unique amino-terminal (pre-S1) sequence. These results also indicate that polymerized human serum albumin or a similar molecule could act as an intermediate receptor, attaching to liver plasma membranes and to the amino acid sequence (pre-S2) shared by the middle and large S proteins but not contained in the small S protein. Images PMID:2649690

  14. Plasma reactor waste management systems

    NASA Technical Reports Server (NTRS)

    Ness, Robert O., Jr.; Rindt, John R.; Ness, Sumitra R.

    1992-01-01

    The University of North Dakota is developing a plasma reactor system for use in closed-loop processing that includes biological, materials, manufacturing, and waste processing. Direct-current, high-frequency, or microwave discharges will be used to produce plasmas for the treatment of materials. The plasma reactors offer several advantages over other systems, including low operating temperatures, low operating pressures, mechanical simplicity, and relatively safe operation. Human fecal material, sunflowers, oats, soybeans, and plastic were oxidized in a batch plasma reactor. Over 98 percent of the organic material was converted to gaseous products. The solids were then analyzed and a large amount of water and acid-soluble materials were detected. These materials could possibly be used as nutrients for biological systems.

  15. Plasma induced DNA damage: Comparison with the effects of ionizing radiation

    NASA Astrophysics Data System (ADS)

    Lazović, S.; Maletić, D.; Leskovac, A.; Filipović, J.; Puač, N.; Malović, G.; Joksić, G.; Petrović, Z. Lj.

    2014-09-01

    We use human primary fibroblasts for comparing plasma and gamma rays induced DNA damage. In both cases, DNA strand breaks occur, but of fundamentally different nature. Unlike gamma exposure, contact with plasma predominantly leads to single strand breaks and base-damages, while double strand breaks are mainly consequence of the cell repair mechanisms. Different cell signaling mechanisms are detected confirming this (ataxia telangiectasia mutated - ATM and ataxia telangiectasia and Rad3 related - ATR, respectively). The effective plasma doses can be tuned to match the typical therapeutic doses of 2 Gy. Tailoring the effective dose through plasma power and duration of the treatment enables safety precautions mainly by inducing apoptosis and consequently reduced frequency of micronuclei.

  16. A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

    PubMed

    Kaykhaii, Massoud; Yahyavi, Hossain; Hashemi, Mohammad; Khoshroo, Mohammad Reza

    2016-07-01

    Determination of malondialdehyde (MDA) in human blood plasma is important because of its role as a biomarker of lipid peroxidation in biological and medical sciences. In this work, a miniaturized graphene-based pipette tip solid-phase extraction technique was developed for very efficient extraction of MDA as its dithiobarbituric acid (TBA) adduct from human plasma. Two milligrams of graphene as sorbent were placed into a pipette tip and MDA-TBA compound was extracted and preconcentrated by it, after 4 repeated aspirating/dispensing cycles, then the column was eluted with 80 μL of dimethyl sulfoxide by 4 repeated aspirating/dispensing cycles and elusion was measured spectrofluorimetrically. Various effective parameters such as type and volume of eluent solvent, temperature, sample volume, number of cycles of extraction and desorption, derivatization reaction time, and pH of the sample solution were investigated and optimized. Under optimum conditions, a linear calibration curve was obtained in the range of 0.5-90 μg L(-1) (r (2) = 0.991) with a detection limit of 0.3 μg L(-1). The relative standard deviations for 8 replicate measurements of 10 and 40 μg L(-1) of MDA were found to be 4.51 and 3.78 % respectively. The developed protocol was successfully applied to the determination of MDA in a human blood plasma sample. Graphical Abstract A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

  17. Quantitative Cross-Species Extrapolation between Humans and Fish: The Case of the Anti-Depressant Fluoxetine

    PubMed Central

    Margiotta-Casaluci, Luigi; Owen, Stewart F.; Cumming, Rob I.; de Polo, Anna; Winter, Matthew J.; Panter, Grace H.; Rand-Weaver, Mariann; Sumpter, John P.

    2014-01-01

    Fish are an important model for the pharmacological and toxicological characterization of human pharmaceuticals in drug discovery, drug safety assessment and environmental toxicology. However, do fish respond to pharmaceuticals as humans do? To address this question, we provide a novel quantitative cross-species extrapolation approach (qCSE) based on the hypothesis that similar plasma concentrations of pharmaceuticals cause comparable target-mediated effects in both humans and fish at similar level of biological organization (Read-Across Hypothesis). To validate this hypothesis, the behavioural effects of the anti-depressant drug fluoxetine on the fish model fathead minnow (Pimephales promelas) were used as test case. Fish were exposed for 28 days to a range of measured water concentrations of fluoxetine (0.1, 1.0, 8.0, 16, 32, 64 µg/L) to produce plasma concentrations below, equal and above the range of Human Therapeutic Plasma Concentrations (HTPCs). Fluoxetine and its metabolite, norfluoxetine, were quantified in the plasma of individual fish and linked to behavioural anxiety-related endpoints. The minimum drug plasma concentrations that elicited anxiolytic responses in fish were above the upper value of the HTPC range, whereas no effects were observed at plasma concentrations below the HTPCs. In vivo metabolism of fluoxetine in humans and fish was similar, and displayed bi-phasic concentration-dependent kinetics driven by the auto-inhibitory dynamics and saturation of the enzymes that convert fluoxetine into norfluoxetine. The sensitivity of fish to fluoxetine was not so dissimilar from that of patients affected by general anxiety disorders. These results represent the first direct evidence of measured internal dose response effect of a pharmaceutical in fish, hence validating the Read-Across hypothesis applied to fluoxetine. Overall, this study demonstrates that the qCSE approach, anchored to internal drug concentrations, is a powerful tool to guide the assessment of the sensitivity of fish to pharmaceuticals, and strengthens the translational power of the cross-species extrapolation. PMID:25338069

  18. Microdevice for plasma separation from whole human blood using bio-physical and geometrical effects

    PubMed Central

    Tripathi, Siddhartha; Kumar, Y. V. BalaVarun; Agrawal, Amit; Prabhakar, Amit; Joshi, Suhas S.

    2016-01-01

    In this research work, we present a simple and efficient passive microfluidic device for plasma separation from pure blood. The microdevice has been fabricated using conventional photolithography technique on a single layer of polydimethylsiloxane, and has been extensively tested on whole blood and enhanced (upto 62%) hematocrit levels of human blood. The microdevice employs elevated dimensions of about 100 μm; such elevated dimensions ensure clog-free operation of the microdevice and is relatively easy to fabricate. We show that our microdevice achieves almost 100% separation efficiency on undiluted blood in the flow rate range of 0.3 to 0.5 ml/min. Detailed biological characterization of the plasma obtained from the microdevice is carried out by testing: proteins by ultra-violet spectrophotometric method, hCG (human chorionic gonadotropin) hormone, and conducting random blood glucose test. Additionally, flow cytometry study has also been carried on the separated plasma. These tests attest to the high quality of plasma recovered. The microdevice developed in this work is an outcome of extensive experimental research on understanding the flow behavior and separation phenomenon of blood in microchannels. The microdevice is compact, economical and effective, and is particularly suited in continuous flow operations. PMID:27279146

  19. Rare loss-of-function mutations in ANGPTL family members contribute to plasma triglyceride levels in humans

    PubMed Central

    Romeo, Stefano; Yin, Wu; Kozlitina, Julia; Pennacchio, Len A.; Boerwinkle, Eric; Hobbs, Helen H.; Cohen, Jonathan C.

    2008-01-01

    The relative activity of lipoprotein lipase (LPL) in different tissues controls the partitioning of lipoprotein-derived fatty acids between sites of fat storage (adipose tissue) and oxidation (heart and skeletal muscle). Here we used a reverse genetic strategy to test the hypothesis that 4 angiopoietin-like proteins (ANGPTL3, -4, -5, and -6) play key roles in triglyceride (TG) metabolism in humans. We re-sequenced the coding regions of the genes encoding these proteins and identified multiple rare nonsynonymous (NS) sequence variations that were associated with low plasma TG levels but not with other metabolic phenotypes. Functional studies revealed that all mutant alleles of ANGPTL3 and ANGPTL4 that were associated with low plasma TG levels interfered either with the synthesis or secretion of the protein or with the ability of the ANGPTL protein to inhibit LPL. A total of 1% of the Dallas Heart Study population and 4% of those participants with a plasma TG in the lowest quartile had a rare loss-of-function mutation in ANGPTL3, ANGPTL4, or ANGPTL5. Thus, ANGPTL3, ANGPTL4, and ANGPTL5, but not ANGPTL6, play nonredundant roles in TG metabolism, and multiple alleles at these loci cumulatively contribute to variability in plasma TG levels in humans. PMID:19075393

  20. HPLC/Fluorometric Detection of Carvedilol in Real Human Plasma Samples Using Liquid-Liquid Extraction.

    PubMed

    Yilmaz, Bilal; Arslan, Sakir

    2016-03-01

    A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed to quantify carvedilol in human plasma using an isocratic system with fluorescence detection. The method included a single-step liquid-liquid extraction with diethylether and ethylacetate mixture (3 : 1, v/v). HPLC separation was carried out by reversed-phase chromatography with a mobile phase composed of 20 mM phosphate buffer (pH 7)-acetonitrile (65 : 35, v/v), pumped at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 240 nm (excitation) and 330 nm (emission). The calibration curve for carvedilol was linear from 10 to 250 ng/mL. Intra- and interday precision values for carvedilol in human plasma were <4.93%, and accuracy (relative error) was better than 4.71%. The analytical recovery of carvedilol from human plasma averaged out to 91.8%. The limits of detection and quantification of carvedilol were 3.0 and 10 ng/mL, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 25 mg carvedilol. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. 21 CFR 866.5700 - Whole human plasma or serum immunological test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...

  2. 21 CFR 866.5700 - Whole human plasma or serum immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...

  3. 21 CFR 866.5700 - Whole human plasma or serum immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...

  4. 21 CFR 866.5700 - Whole human plasma or serum immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...

  5. 21 CFR 866.5700 - Whole human plasma or serum immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Whole human plasma or serum immunological test... Systems § 866.5700 Whole human plasma or serum immunological test system. (a) Identification. A whole human plasma or serum immunological test system is a device that consists of reagents used to measure by...

  6. Continuous monitoring of blood volume changes in humans

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.; Greenleaf, J. E.

    1987-01-01

    Use of on-line high-precision mass densitometry for the continuous monitoring of blood volume changes in humans was demonstrated by recording short-term blood volume alterations produced by changes in body position. The mass density of antecubital venous blood was measured continuously for 80 min per session with 0.1 g/l precision at a flow rate of 1.5 ml/min. Additional discrete plasma density and hematocrit measurements gave linear relations between all possible combinations of blood density, plasma density, and hematocrit. Transient filtration phenomena were revealed that are not amenable to discontinuous measurements.

  7. Development of certified reference materials for electrolytes in human serum (GBW09124-09126).

    PubMed

    Feng, Liuxing; Wang, Jun; Cui, Yanjie; Shi, Naijie; Li, Haifeng; Li, Hongmei

    2017-05-01

    Three reference materials, at relatively low, middle, and high concentrations, were developed for analysis of the mass fractions of electrolytes (K, Ca, Na, Mg, Cl, and Li) in human serum. The reference materials were prepared by adding high purity chloride salts to normal human serum. The concentration range of the three levels is within ±20% of normal human serum. It was shown that 14 units with duplicate analysis is enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for 1 week at 40 °C and long-term stability test for 14 months. The certification methods of the six elements include isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), atomic absorption spectroscopy (AAS), ion chromatography (IC), and ion-selective electrode (ISE). The certification methods were validated by international comparisons among a number of national metrology institutes (NMIs). The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the analytical methods, homogeneity, and stability. The range of the expanded uncertainties of all the elements is from 2.2% to 3.9%. The certified reference materials (CRMs) are primarily intended for use in the calibration and validation of procedures in clinical analysis for the determination of electrolytes in human serum or plasma. Graphical Abstract Certified reference materials for K, Ca, Mg, Na, Cl and Li in human serum (GBW09124-09126).

  8. Genetic control of the alternative pathway of complement in humans and age-related macular degeneration

    PubMed Central

    Hecker, Laura A.; Edwards, Albert O.; Ryu, Euijung; Tosakulwong, Nirubol; Baratz, Keith H.; Brown, William L.; Issa, Peter Charbel; Scholl, Hendrik P.; Pollok-Kopp, Beatrix; Schmid-Kubista, Katharina E.; Bailey, Kent R.; Oppermann, Martin

    2010-01-01

    Activation of the alternative pathway of complement is implicated in common neurodegenerative diseases including age-related macular degeneration (AMD). We explored the impact of common variation in genes encoding proteins of the alternative pathway on complement activation in human blood and in AMD. Genetic variation across the genes encoding complement factor H (CFH), factor B (CFB) and component 3 (C3) was determined. The influence of common haplotypes defining transcriptional and translational units on complement activation in blood was determined in a quantitative genomic association study. Individual haplotypes in CFH and CFB were associated with distinct and novel effects on plasma levels of precursors, regulators and activation products of the alternative pathway of complement in human blood. Further, genetic variation in CFH thought to influence cell surface regulation of complement did not alter plasma complement levels in human blood. Plasma markers of chronic activation (split-products Ba and C3d) and an activating enzyme (factor D) were elevated in AMD subjects. Most of the elevation in AMD was accounted for by the genetic variation controlling complement activation in human blood. Activation of the alternative pathway of complement in blood is under genetic control and increases with age. The genetic variation associated with increased activation of complement in human blood also increased the risk of AMD. Our data are consistent with a disease model in which genetic variation in the complement system increases the risk of AMD by a combination of systemic complement activation and abnormal regulation of complement activation in local tissues. PMID:19825847

  9. Mining the human plasma proteome with three-dimensional strategies by high-resolution Quadrupole Orbitrap Mass Spectrometry.

    PubMed

    Zhao, Yan; Chang, Cheng; Qin, Peibin; Cao, Qichen; Tian, Fang; Jiang, Jing; Li, Xianyu; Yu, Wenfeng; Zhu, Yunping; He, Fuchu; Ying, Wantao; Qian, Xiaohong

    2016-01-21

    Human plasma is a readily available clinical sample that reflects the status of the body in normal physiological and disease states. Although the wide dynamic range and immense complexity of plasma proteins are obstacles, comprehensive proteomic analysis of human plasma is necessary for biomarker discovery and further verification. Various methods such as immunodepletion, protein equalization and hyper fractionation have been applied to reduce the influence of high-abundance proteins (HAPs) and to reduce the high level of complexity. However, the depth at which the human plasma proteome has been explored in a relatively short time frame has been limited, which impedes the transfer of proteomic techniques to clinical research. Development of an optimal strategy is expected to improve the efficiency of human plasma proteome profiling. Here, five three-dimensional strategies combining HAP depletion (the 1st dimension) and protein fractionation (the 2nd dimension), followed by LC-MS/MS analysis (the 3rd dimension) were developed and compared for human plasma proteome profiling. Pros and cons of the five strategies are discussed for two issues: HAP depletion and complexity reduction. Strategies A and B used proteome equalization and tandem Seppro IgY14 immunodepletion, respectively, as the first dimension. Proteome equalization (strategy A) was biased toward the enrichment of basic and low-molecular weight proteins and had limited ability to enrich low-abundance proteins. By tandem removal of HAPs (strategy B), the efficiency of HAP depletion was significantly increased, whereas more off-target proteins were subtracted simultaneously. In the comparison of complexity reduction, strategy D involved a deglycosylation step before high-pH RPLC separation. However, the increase in sequence coverage did not increase the protein number as expected. Strategy E introduced SDS-PAGE separation of proteins, and the results showed oversampling of HAPs and identification of fewer proteins. Strategy C combined single Seppro IgY14 immunodepletion, high-pH RPLC fractionation and LC-MS/MS analysis. It generated the largest dataset, containing 1544 plasma protein groups and 258 newly identified proteins in a 30-h-machine-time analysis, making it the optimum three-dimensional strategy in our study. Further analysis of the integrated data from the five strategies showed identical distribution patterns in terms of sequence features and GO functional analysis with the 1929-plasma-protein dataset, further supporting the reliability of our plasma protein identifications. The characterization of 20 cytokines in the concentration range from sub-nanograms/milliliter to micrograms/milliliter demonstrated the sensitivity of the current strategies. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. The metabolism of the anti-inflammatory drug eterylate in rat, dog and man.

    PubMed

    Wood, S G; John, B A; Chasseaud, L F; Johnstone, I; Biggs, S R; Hawkins, D R; Priego, J G; Darragh, A; Lambe, R F

    1983-12-01

    Oral doses of 14C-eterylate were well absorbed by rat and man and excreted mainly in the urine (94% dose by rat in three days and 91% by man in five days). Oral doses to dogs were excreted in similar proportions in both the urine and faeces, although faecal 14C was probably derived in part, from biliary-excreted material. Peak plasma 14C and drug concn. were generally reached between one and three hours after oral doses. In humans, only two metabolites, salicylic acid and 4-acetamido-phenoxyacetic acid, were detected in plasma. The latter was cleared more rapidly than the former and hence plasma salicyclate concn. reached a peak (10.9 and 19.8 micrograms/ml in Subjects 1 and 2, respectively) and initially declined with a half-life of about two-three hours. Plasma 4-acetamidophenoxyacetic acid concn. reached a peak (4.3, 10.0 micrograms/ml, respectively) and declined with a half-life of about one hour. Tissue concn. of 14C were generally greater in dogs than in rats. Highest conc. occurred at three hours in dogs and at one hour in rats. Apart from those in the liver and kidneys, tissue concn. were lower than those in the corresponding plasma. Unchanged drug was not detected in urine or plasma of any species and was rapidly metabolized in human plasma. The major 14C components in human urine were identified as salicyluric acid and 4-acetamidophenoxyacetic acid; minor metabolites were salicylic acid, gentisic acid and paracetamol. These metabolites were also detected in rat urine albeit in different proportions to those in human urine. Dog urine contained less of these metabolites and a major proportion of the 14C was associated with relatively non-polar components. Although salicylic acid and 4-acetamidophenoxyacetic acid were the only major circulating metabolites in man and rat, dog plasma also contained the non-polar urine metabolites.

  11. Stereoselective binding of doxazosin enantiomers to plasma proteins from rats, dogs and humans in vitro

    PubMed Central

    Sun, Jia-an; Kong, De-zhi; Zhen, Ya-qin; Li, Qing; Zhang, Wei; Zhang, Jiang-hua; Yin, Zhi-wei; Ren, Lei-ming

    2013-01-01

    Aim: (±)Doxazosin is a long-lasting inhibitor of α1-adrenoceptors that is widely used to treat benign prostatic hyperplasia and lower urinary tract symptoms. In this study we investigated the stereoselective binding of doxazosin enantiomers to the plasma proteins of rats, dogs and humans in vitro. Methods: Human, dog and rat plasma were prepared. Equilibrium dialysis was used to determine the plasma protein binding of each enantiomer in vitro. Chiral HPLC with fluorescence detection was used to measure the drug concentrations on each side of the dialysis membrane bag. Results: Both the enantiomers were highly bound to the plasma proteins of rats, dogs and humans [(−)doxazosin: 89.4%–94.3%; (+)doxazosin: 90.9%–95.4%]. (+)Doxazosin exhibited significantly higher protein binding capacities than (−)doxazosin in all the three species, and the difference in the bound concentration (Cb) between the two enantiomers was enhanced as their concentrations were increased. Although the percentage of the plasma protein binding in the dog plasma was significantly lower than that in the human plasma at 400 and 800 ng/mL, the corrected percentage of plasma protein binding was dog>human>rat. Conclusion: (−)Doxazosin and (+)doxazosin show stereoselective plasma protein binding with a significant species difference among rats, dogs and humans. PMID:24241343

  12. A sensitive LC-MS/MS method for simultaneous determination of amygdalin and paeoniflorin in human plasma and its application.

    PubMed

    Li, Xiaobing; Shi, Fuguo; Gu, Pan; Liu, Lingye; He, Hua; Ding, Li

    2014-04-01

    A simple and sensitive HPLC-MS/MS method was developed and fully validated for the simultaneous determination of amygdalin (AD) and paeoniflorin (PF) in human plasma. For both analytes, the method exhibited high sensitivity (LLOQs of 0.6ng/mL) by selecting the ammonium adduct ions ([M+NH4](+)) as the precursor ions and good linearity over the concentration range of 0.6-2000ng/mL with the correlation coefficients>0.9972. The intra- and inter-day precision was lower than 10% in relation to relative standard deviation, while accuracy was within ±2.3% in terms of relative error for both analytes. The developed method was successfully applied to a pilot pharmacokinetic study of AD and PF in healthy volunteers after intravenous infusion administration of Huoxue-Tongluo lyophilized powder for injection. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The Human Plasma Proteome Draft of 2017: Building on the Human Plasma PeptideAtlas from Mass Spectrometry and Complementary Assays.

    PubMed

    Schwenk, Jochen M; Omenn, Gilbert S; Sun, Zhi; Campbell, David S; Baker, Mark S; Overall, Christopher M; Aebersold, Ruedi; Moritz, Robert L; Deutsch, Eric W

    2017-12-01

    Human blood plasma provides a highly accessible window to the proteome of any individual in health and disease. Since its inception in 2002, the Human Proteome Organization's Human Plasma Proteome Project (HPPP) has been promoting advances in the study and understanding of the full protein complement of human plasma and on determining the abundance and modifications of its components. In 2017, we review the history of the HPPP and the advances of human plasma proteomics in general, including several recent achievements. We then present the latest 2017-04 build of Human Plasma PeptideAtlas, which yields ∼43 million peptide-spectrum matches and 122,730 distinct peptide sequences from 178 individual experiments at a 1% protein-level FDR globally across all experiments. Applying the latest Human Proteome Project Data Interpretation Guidelines, we catalog 3509 proteins that have at least two non-nested uniquely mapping peptides of nine amino acids or more and >1300 additional proteins with ambiguous evidence. We apply the same two-peptide guideline to historical PeptideAtlas builds going back to 2006 and examine the progress made in the past ten years in plasma proteome coverage. We also compare the distribution of proteins in historical PeptideAtlas builds in various RNA abundance and cellular localization categories. We then discuss advances in plasma proteomics based on targeted mass spectrometry as well as affinity assays, which during early 2017 target ∼2000 proteins. Finally, we describe considerations about sample handling and study design, concluding with an outlook for future advances in deciphering the human plasma proteome.

  14. A Lower Olfactory Capacity Is Related to Higher Circulating Concentrations of Endocannabinoid 2-Arachidonoylglycerol and Higher Body Mass Index in Women.

    PubMed

    Pastor, Antoni; Fernández-Aranda, Fernando; Fitó, Montserrat; Jiménez-Murcia, Susana; Botella, Cristina; Fernández-Real, Jose M; Frühbeck, Gema; Tinahones, Francisco J; Fagundo, Ana B; Rodriguez, Joan; Agüera, Zaida; Langohr, Klaus; Casanueva, Felipe F; de la Torre, Rafael

    2016-01-01

    The endocannabinoid (eCB) system can promote food intake by increasing odor detection in mice. The eCB system is over-active in human obesity. Our aim is to measure circulating eCB concentrations and olfactory capacity in a human sample that includes people with obesity and explore the possible interaction between olfaction, obesity and the eCB system. The study sample was made up of 161 females with five groups of body mass index sub-categories ranging from under-weight to morbidly obese. We assessed olfactory capacity with the "Sniffin´Sticks" test, which measures olfactory threshold-discrimination-identification (TDI) capacity. We measured plasma concentrations of the eCBs 2-arachidonoylglycerol (2-AG) and N-arachidonoylethanolamine or anandamide (AEA), and several eCB-related compounds, 2-acylglycerols and N-acylethanolamines. 2-AG and other 2-acylglycerols fasting plasma circulating plasma concentrations were higher in obese and morbidly obese subjects. AEA and other N-acylethanolamine circulating concentrations were lower in under-weight subjects. Olfactory TDI scores were lower in obese and morbidly obese subjects. Lower TDI scores were independently associated with higher 2-AG fasting plasma circulating concentrations, higher %body fat, and higher body mass index, after controlling for age, smoking, menstruation, and use of contraceptives. Our results show that obese subjects have a lower olfactory capacity than non-obese ones and that elevated fasting plasma circulating 2-AG concentrations in obesity are linked to a lower olfactory capacity. In agreement with previous studies we show that eCBs AEA and 2-AG, and their respective congeners have a distinct profile in relation to body mass index. The present report is the first study in humans in which olfactory capacity and circulating eCB concentrations have been measured in the same subjects.

  15. The effects of cannabinoids on serum cortisol and prolactin in humans

    PubMed Central

    Ranganathan, Mohini; Braley, Gabriel; Pittman, Brian; Cooper, Thomas; Perry, Edward; Krystal, John; D’Souza, Deepak Cyril

    2010-01-01

    Background Cannabis is one of the most widely used illicit substances, and there is growing interest in the therapeutic applications of cannabinoids. While known to modulate neuroendocrine function, the precise acute and chronic dose-related effects of cannabinoids in humans are not well-known. Furthermore, the existing literature on the neuroendocrine effects of cannabinoids is limited by small sample sizes (n=6–22), heterogeneous samples with regard to cannabis exposure (lumping users and nonusers), lack of controlling for chronic cannabis exposure, differing methodologies, and limited dose–response data. Delta-9-tetrahydrocannabinol (Δ-9-THC) was hypothesized to produce dose-related increases in plasma cortisol levels and decreases in plasma prolactin levels. Furthermore, relative to controls, frequent users of cannabis were hypothesized to show altered baseline levels of these hormones and blunted Δ-9-THC-induced changes of these hormones. Materials and methods Pooled data from a series of laboratory studies with multiple doses of intravenous Δ-9-THC in healthy control subjects (n=36) and frequent users of cannabis (n=40) was examined to characterize the acute, chronic, and acute on chronic effects of cannabinoids on plasma cortisol and prolactin levels. Hormone levels were measured before (baseline) and 70 min after administration of each dose of Δ-9-THC. Data were analyzed using linear mixed models with +70 min hormonal levels as the dependant variable and baseline hormonal level as the covariate. Results At socially relevant doses, Δ-9-THC raised plasma cortisol levels in a dose-dependent manner but frequent users showed blunted increases relative to healthy controls. Frequent users also had lower baseline plasma prolactin levels relative to healthy controls. Conclusions These group differences may be related to the development of tolerance to the neuroendocrine effects of cannabinoids. Alternatively, these results may reflect inherent differences in neuroendocrine function in frequent users of cannabis and not a consequence of cannabis use. PMID:19083209

  16. Advances in display technology III; Proceedings of the Meeting, Los Angeles, CA, January 18, 19, 1983

    NASA Astrophysics Data System (ADS)

    Schlam, E.

    1983-01-01

    Human factors in visible displays are discussed, taking into account an introduction to color vision, a laser optometric assessment of visual display viewability, the quantification of color contrast, human performance evaluations of digital image quality, visual problems of office video display terminals, and contemporary problems in airborne displays. Other topics considered are related to electroluminescent technology, liquid crystal and related technologies, plasma technology, and display terminal and systems. Attention is given to the application of electroluminescent technology to personal computers, electroluminescent driving techniques, thin film electroluminescent devices with memory, the fabrication of very large electroluminescent displays, the operating properties of thermally addressed dye switching liquid crystal display, light field dichroic liquid crystal displays for very large area displays, and hardening military plasma displays for a nuclear environment.

  17. Arylesterase activities in the plasma of rats, rabbits and humans on low- and high-cholesterol diets.

    PubMed

    Beynen, A C; Weinans, G J; Katan, M B

    1984-01-01

    Arylesterase activities were measured with beta-naphthylpropionate and/or alpha-naphthylacetate as substrate in the plasma of rats, rabbits and humans on low- and high-cholesterol diets. The plasma esterase activities measured with alpha-naphthylacetate were similar in rats, rabbits and humans. With beta-naphthylpropionate as a substrate, rabbits were found to have a markedly higher esterase activity than rats and humans. Basal plasma esterase activity was significantly higher in an inbred rat strain which is hyporesponsive to dietary cholesterol than in a hyperresponsive strain. In rats, but not in humans and rabbits, plasma esterase activity was significantly increased by a high-cholesterol diet. In individual humans and random-bred rabbits and rats there was no association between initial plasma total esterase activity and the subsequent plasma cholesterol response to cholesterol feeding. We suggest that arylesterases are associated with cholesterol metabolism and with the response to dietary cholesterol in rats; evidence for such a role in rabbits and humans is, however, inconclusive.

  18. On the wetting properties of human stratum corneum epidermidis surface exposed to cold atmospheric-pressure pulsed plasma

    NASA Astrophysics Data System (ADS)

    Athanasopoulos, D.; Svarnas, P.; Ladas, S.; Kennou, S.; Koutsoukos, P.

    2018-05-01

    The Stratum corneum is the outermost layer of the skin, acting as a protective barrier of the epidermis, and its surface properties are directly related to the spreading of topically applied drugs and cosmetics. Numerous works have been devoted to the wettability of this layer over the past 70 years, but, despite the extensive application of atmospheric-pressure plasmas to dermatology, stratum corneum wettability with respect to plasma-induced species has never been considered. The present report assesses the treatment of human stratum corneum epidermidis by atmospheric-pressure pulsed cold plasma-jets for various time intervals and both chemical and morphological modifications are probed. The increase and saturation of the surface free energy due to functionalization are demonstrated, whereas prolonged treatment leads to tissue local disruption (tissue integrity is lost, and stratum corneum looks exfoliated, porous, and even thermally damaged). The latter point arises skepticism about the common practice of contacting atmospheric-pressure plasmas with skin without any previous precautions since the lost skin surface integrity may allow the penetration of pathogenic microorganisms.

  19. Comparison of functional aspects of the coagulation cascade in human and sea turtle plasmas.

    PubMed

    Soslau, Gerald; Wallace, Bryan; Vicente, Catherine; Goldenberg, Seth J; Tupis, Todd; Spotila, James; George, Robert; Paladino, Frank; Whitaker, Brent; Violetta, Gary; Piedra, Rotney

    2004-08-01

    Functional hemostatic pathways are critical for the survival of all vertebrates and have been evolving for more than 400 million years. The overwhelming majority of studies of hemostasis in vertebrates have focused on mammals with very sparse attention paid to reptiles. There have been virtually no studies of the coagulation pathway in sea turtles whose ancestors date back to the Jurassic period. Sea turtles are often exposed to rapidly altered environmental conditions during diving periods. This may reduce their blood pH during prolonged hypoxic dives. This report demonstrates that five species of turtles possess only one branch of the mammalian coagulation pathway, the extrinsic pathway. Mixing studies of turtle plasmas with human factor-deficient plasmas indicate that the intrinsic pathway factors VIII and IX are present in turtle plasma. These two factors may play a significant role in supporting the extrinsic pathway by feedback loops. The intrinsic factors, XI and XII are not detected which would account for the inability of reagents to induce coagulation via the intrinsic pathway in vitro. The analysis of two turtle factors, factor II (prothrombin) and factor X, demonstrates that they are antigenically/functionally similar to the corresponding human factors. The turtle coagulation pathway responds differentially to both pH and temperature relative to each turtle species and relative to human samples. The coagulation time (prothrombin time) increases as the temperature decreases between 37 and 15 degrees C. The increased time follows a linear relationship, with similar slopes for loggerhead, Kemps ridley and hawksbill turtles as well as for human samples. Leatherback turtle samples show a dramatic nonlinear increased time below 23 degrees C, and green turtle sample responses were similar but less dramatic. All samples also showed increased prothrombin times as the pH decreased from 7.8 to 6.4, except for three turtle species. The prothrombin times decreased, to varying extents, in a linear fashion relative to reduced pH with the rate of change greatest in leatherbacks>green>loggerhead turtles. All studies were conducted with reagents developed for human samples which would impact on the quantitative results with the turtle samples, but are not likely to alter the qualitative results. These comparative studies of the coagulation pathway in sea turtles and humans could enhance our knowledge of structure/function relationships and evolution of coagulation factors.

  20. The comparison of DNA damage induced by micro DBD plasma and low energy electron for curing human diseases

    NASA Astrophysics Data System (ADS)

    Park, Yeunsoo

    2015-09-01

    It is well known that low energy electrons (LEE, especially below 10 eV) can generate DNA damage via indirect action named dissociative electron attachment (DEA). We can now explain some parts of the exact mechanism on DNA damage by LEE collision with direct ionization effect when cancer patients get the radiotherapy. It is kind of remarkable information in the field of radiation therapy. However, it is practically very difficult to directly apply this finding to human disease cure due to difficulty of LEE therapy actualization and request of further clinical studies. Recently, there is a novel challenge in plasma application, that is, how we can apply plasma technology to diagnosis and treatment of many serious diseases like cancer. Cold atmospheric pressure plasma (CAPP) is a very good source to apply to plasma medicine and bio-applications because of low temperature, low cost, and easy handling. Some scientists have already reported good results related to clinical plasma application. The purposes of this study are to further find out exact mechanisms of DNA damage by LEE at the molecular level, to verify new DNA damage like structural alteration on DNA subunits and to compare DNA damage by LEE and plasma source. We will keep expanding our study to DNA damage by plasma source to develop plasma-based new medical and biological applications. We will show some recent results, DNA damage by LEE and non-thermal plasma.

  1. Preparation of a novel sorptive stir bar based on vinylpyrrolidone-ethylene glycol dimethacrylate monolithic polymer for the simultaneous extraction of diazepam and nordazepam from human plasma.

    PubMed

    Torabizadeh, Mahsa; Talebpour, Zahra; Adib, Nuoshin; Aboul-Enein, Hassan Y

    2016-04-01

    A new monolithic coating based on vinylpyrrolidone-ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The polymerization step was performed using different contents of monomer, cross-linker and porogenic solvent, and the best formulation was selected. The quality of the prepared vinylpyrrolidone-ethylene glycol dimethacrylate stir bars was satisfactory, demonstrating good repeatability within batch (relative standard deviation < 3.5%) and acceptable reproducibility between batches (relative standard deviation < 6.0%). The prepared stir bar was utilized in combination with ultrasound-assisted liquid desorption, followed by high-performance liquid chromatography with ultraviolet detection for the simultaneous determination of diazepam and nordazepam in human plasma samples. To optimize the extraction step, a three-level, four-factor, three-block Box-Behnken design was applied. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for diazepam (36-1200 ng/mL) and nordazepam (25-1200 ng/mL), with correlation coefficients of 0.9986 and 0.9968 and detection limits of 12 and 10 ng/mL, respectively. The intra- and interday recovery ranged from 93 to 106%, and the relative standard deviations were less than 6%. Finally, the proposed method was successfully applied to the analysis of diazepam and nordazepam at their therapeutic levels in human plasma. The novelty of this study is the improved polarity of the stir bar coating and its application for the simultaneous extraction of diazepam and its active metabolite, nordazepam in human plasma sample. The method was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of diazepam and nordazepam in biological fluids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Predictive dose-based estimation of systemic exposure multiples in mouse and monkey relative to human for antisense oligonucleotides with 2'-o-(2-methoxyethyl) modifications.

    PubMed

    Yu, Rosie Z; Grundy, John S; Henry, Scott P; Kim, Tae-Won; Norris, Daniel A; Burkey, Jennifer; Wang, Yanfeng; Vick, Andrew; Geary, Richard S

    2015-01-20

    Evaluation of species differences and systemic exposure multiples (or ratios) in toxicological animal species versus human is an ongoing exercise during the course of drug development. The systemic exposure ratios are best estimated by directly comparing area under the plasma concentration-time curves (AUCs), and sometimes by comparing the dose administered, with the dose being adjusted either by body surface area (BSA) or body weight (BW). In this study, the association between AUC ratio and the administered dose ratio from animals to human were studied using a retrospective data-driven approach. The dataset included nine antisense oligonucleotides (ASOs) with 2'-O-(2-methoxyethyl) modifications, evaluated in two animal species (mouse and monkey) following single and repeated parenteral administrations. We found that plasma AUCs were similar between ASOs within the same species, and are predictable to human exposure using a single animal species, either mouse or monkey. Between monkey and human, the plasma exposure ratio can be predicted directly based on BW-adjusted dose ratios, whereas between mouse and human, the exposure ratio would be nearly fivefold lower in mouse compared to human based on BW-adjusted dose values. Thus, multiplying a factor of 5 for the mouse BW-adjusted dose would likely provide a reasonable AUC exposure estimate in human at steady-state.

  3. Albuminuria is associated with an increased prostasin in urine while aldosterone has no direct effect on urine and kidney tissue abundance of prostasin.

    PubMed

    Oxlund, Christina; Kurt, Birgül; Schwarzensteiner, Ilona; Hansen, Mie R; Stæhr, Mette; Svenningsen, Per; Jacobsen, Ib A; Hansen, Pernille B; Thuesen, Anne D; Toft, Anja; Hinrichs, Gitte R; Bistrup, Claus; Jensen, Boye L

    2017-06-01

    The proteinase prostasin is a candidate mediator for aldosterone-driven proteolytic activation of the epithelial sodium channel (ENaC). It was hypothesized that the aldosterone-mineralocorticoid receptor (MR) pathway stimulates prostasin abundance in kidney and urine. Prostasin was measured in plasma and urine from type 2 diabetic patients with resistant hypertension (n = 112) randomized to spironolactone/placebo in a clinical trial. Prostasin protein level was assessed by immunoblotting in (1) human and rat urines with/without nephrotic syndrome, (2) human nephrectomy tissue, (3) urine and kidney from aldosterone synthase-deficient (AS -/- ) mice and ANGII- and aldosterone-infused mice, and in (4) kidney from adrenalectomized rats. Serum aldosterone concentration related to prostasin concentration in urine but not in plasma. Plasma prostasin concentration increased significantly after spironolactone compared to control. Urinary prostasin and albumin related directly and were reduced by spironolactone. In patients with nephrotic syndrome, urinary prostasin protein was elevated compared to controls. In rat nephrosis, proteinuria coincided with increased urinary prostasin, unchanged kidney tissue prostasin, and decreased plasma prostasin while plasma aldosterone was suppressed. Prostasin protein abundance in human nephrectomy tissue was similar across gender and ANGII inhibition regimens. Prostasin urine abundance was not different in AS -/- and aldosterone-infused mice. Prostasin kidney level was not different from control in adrenalectomized rats and AS -/- mice. We found no evidence for a direct relationship between mineralocorticoid receptor signaling and kidney and urine prostasin abundance. The reduction of urinary prostasin in spironolactone-treated patients is most likely the result of an improved glomerular filtration barrier function and generally reduced proteinuria.

  4. Spectrofluorometric determination of methocarbamol in pharmaceutical preparations and human plasma.

    PubMed

    Walash, Mohamed; Belal, Fathalla; Eid, Manal; EL Abass, Samah Abo

    2011-03-01

    A simple, sensitive and rapid spectrofluorometric method for determination of methocarbamol in pharmaceutical formulations and spiked human plasma has been developed. The proposed method is based on the measurement of the native fluorescence of methocarbamol in methanol at 313 nm after excitation at 277 nm. The relative fluorescence intensity-concentration plot was rectilinear over the range of 0.05-2.0 μg/mL, with good correlation (r=0.9999), limit of detection of 0.007 μg/ mL and a lower limit of quantification of 0.022 μg/ mL. The described method was successfully applied for the determination of methocarbamol in its tablets without interference from co-formulated drugs, such as aspirin, diclofenac, paracetamol and ibuprofen, The results obtained were in good agreement with those obtained using the official method (USP 30).The high sensitivity of the method allowed the determination of the studied drug in spiked human plasma with average percentage recovery of 99.42 ± 3.84. © Springer Science+Business Media, LLC 2010

  5. Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of aniracetam in human plasma.

    PubMed

    Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun

    2007-10-15

    A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.

  6. A validated high-performance liquid chromatographic method for the determination of glibenclamide in human plasma and its application to pharmacokinetic studies.

    PubMed

    Niopas, Ioannis; Daftsios, Athanasios C

    2002-05-15

    Glibenclamide is a potent second generation oral sulfonylurea antidiabetic agent widely used for the treatment of type II diabetes melitus. A rapid, sensitive, precise, accurate and specific HPLC assay for the determination of glibenclamide in human plasma was developed and validated. After addition of flufenamic acid as internal standard, the analytes were isolated from human plasma by liquid-liquid extraction. The method was linear in the 10-400 ng/ml concentration range (r > 0.999). Recovery for glibenclamide was greater than 91.5% and for internal standard was 93.5%. Within-day and between-day precision, expressed as the relative standard deviation (RSD%), ranged from 1.4 to 5.9% and 5.8 to 6.6%, respectively. Assay accuracy was better than 93.4%. The assay was used to estimate the pharmacokinetics of glibenclamide after oral administration of a 5 mg tablet of glibenclamide to 18 healthy volunteers.

  7. Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography.

    PubMed

    Jabor, Valquíria A P; Lanchote, Vera L; Bonato, Pierina S

    2002-09-01

    This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.

  8. Pharmacokinetics of the dipeptidyl peptidase 4 inhibitor saxagliptin in rats, dogs, and monkeys and clinical projections.

    PubMed

    Fura, Aberra; Khanna, Ashish; Vyas, Viral; Koplowitz, Barry; Chang, Shu-Ying; Caporuscio, Christian; Boulton, David W; Christopher, Lisa J; Chadwick, Kristina D; Hamann, Lawrence G; Humphreys, W Griffith; Kirby, Mark

    2009-06-01

    Saxagliptin is a potent, selective, reversible dipeptidyl peptidase 4 (DPP4) inhibitor specifically designed for extended inhibition of the DPP4 enzyme and is currently under development for the treatment of type-2 diabetes. The pharmacokinetics of saxagliptin were evaluated in rats, dogs, and monkeys and used to predict its human pharmacokinetics. Saxagliptin was rapidly absorbed and had good bioavailability (50-75%) in the species tested. The plasma clearance of saxagliptin was higher in rats (115 ml/min/kg) than in dogs (9.3 ml/min/kg) and monkeys (14.5 ml/min/kg) and was predicted to be low to moderate in humans. The plasma elimination half-life was between 2.1 and 4.4 h in rats, dogs, and monkeys, and both metabolism and renal excretion contributed to the overall elimination. The primary metabolic clearance pathway involved the formation of a significant circulating, pharmacologically active hydroxylated metabolite, M2. The volume of distribution values observed in rats, dogs, and monkeys (1.3-5.2 l/kg) and predicted for humans (2.7 l/kg) were greater than those for total body water, indicating extravascular distribution. The in vitro serum protein binding was low (< or =30%) in rats, dogs, monkeys, and humans. After intra-arterial administration of saxagliptin to Sprague-Dawley and Zucker diabetic fatty rats, higher levels of saxagliptin and M2 were observed in the intestine (a proposed major site of drug action) relative to that in plasma. Saxagliptin has prolonged pharmacodynamic properties relative to its plasma pharmacokinetic profile, presumably due to additional contributions from M2, distribution of saxagliptin and M2 to the intestinal tissue, and prolonged dissociation of both saxagliptin and M2 from DPP4.

  9. Plasma induced DNA damage: Comparison with the effects of ionizing radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazović, S.; Maletić, D.; Puač, N.

    2014-09-22

    We use human primary fibroblasts for comparing plasma and gamma rays induced DNA damage. In both cases, DNA strand breaks occur, but of fundamentally different nature. Unlike gamma exposure, contact with plasma predominantly leads to single strand breaks and base-damages, while double strand breaks are mainly consequence of the cell repair mechanisms. Different cell signaling mechanisms are detected confirming this (ataxia telangiectasia mutated - ATM and ataxia telangiectasia and Rad3 related - ATR, respectively). The effective plasma doses can be tuned to match the typical therapeutic doses of 2 Gy. Tailoring the effective dose through plasma power and duration of themore » treatment enables safety precautions mainly by inducing apoptosis and consequently reduced frequency of micronuclei.« less

  10. Differences in the Lipoprotein Distribution of Free and Liposome-Associated All-trans-Retinoic Acid in Human, Dog, and Rat Plasma Are Due to Variations in Lipoprotein Lipid and Protein Content

    PubMed Central

    Wasan, Kishor M.; Ramaswamy, Manisha; Ng, Samson P.; Wong, Wesley; Parrott, Steven C.; Ojwang, Joshua O.; Wallace, Thomas; Cossum, Paul A.

    1998-01-01

    The objective of the proposed study was to determine the distribution in plasma lipoprotein of free all-trans retinoic acid (ATRA) and liposomal ATRA (Atragen; composed of dimyristoyl phosphatidylcholine and soybean oil) following incubation in human, rat, and dog plasma. When ATRA and Atragen at concentrations of 1, 5, 10, and 25 μg/ml were incubated in human and rat plasma for 5, 60, and 180 min, the majority of the tretinoin was recovered in the lipoprotein-deficient plasma fraction. However, when ATRA and Atragen were incubated in dog plasma, the majority of the tretinoin (>40%) was recovered in the high-density lipoprotein (HDL) fraction. No differences in the plasma distribution between ATRA and Atragen were found. These data suggest that a significant percentage of tretinoin associates with plasma lipoproteins (primarily the HDL fraction) upon incubation in human, dog, and rat plasma. Differences between the lipoprotein lipid and protein profiles in human plasma and in dog and rat plasma influenced the plasma distribution of ATRA and Atragen. Differences in lipoprotein distribution between ATRA and Atragen were not observed, suggesting that the drug’s distribution in plasma is not influenced by its incorporation into these liposomes. PMID:9660998

  11. Physical activity affects plasma coenzyme Q10 levels differently in young and old humans.

    PubMed

    Del Pozo-Cruz, Jesús; Rodríguez-Bies, Elisabet; Ballesteros-Simarro, Manuel; Navas-Enamorado, Ignacio; Tung, Bui Thanh; Navas, Plácido; López-Lluch, Guillermo

    2014-04-01

    Coenzyme Q (Q) is a key lipidic compound for cell bioenergetics and membrane antioxidant activities. It has been shown that also has a central role in the prevention of oxidation of plasma lipoproteins. Q has been associated with the prevention of cholesterol oxidation and several aging-related diseases. However, to date no clear data on the levels of plasma Q during aging are available. We have measured the levels of plasmatic Q10 and cholesterol in young and old individuals showing different degrees of physical activity. Our results indicate that plasma Q10 levels in old people are higher that the levels found in young people. Our analysis also indicates that there is no a relationship between the degree of physical activity and Q10 levels when the general population is studied. However, very interestingly, we have found a different tendency between Q10 levels and physical activity depending on the age of individuals. In young people, higher activity correlates with lower Q10 levels in plasma whereas in older adults this ratio changes and higher activity is related to higher plasma Q10 levels and higher Q10/Chol ratios. Higher Q10 levels in plasma are related to lower lipoperoxidation and oxidized LDL levels in elderly people. Our results highlight the importance of life habits in the analysis of Q10 in plasma and indicate that the practice of physical activity at old age can improve antioxidant capacity in plasma and help to prevent cardiovascular diseases.

  12. Purine nucleoside phosphorylase and xanthine oxidase activities in erythrocytes and plasma from marine, semiaquatic and terrestrial mammals.

    PubMed

    López-Cruz, Roberto I; Pérez-Milicua, Myrna Barjau; Crocker, Daniel E; Gaxiola-Robles, Ramón; Bernal-Vertiz, Jaime A; de la Rosa, Alejandro; Vázquez-Medina, José P; Zenteno-Savín, Tania

    2014-05-01

    Purine nucleoside phosphorylase (PNP) and xanthine oxidase (XO) are key enzymes involved in the purine salvage pathway. PNP metabolizes purine bases to synthetize purine nucleotides whereas XO catalyzes the oxidation of purines to uric acid. In humans, PNP activity is reported to be high in erythrocytes and XO activity to be low in plasma; however, XO activity increases after ischemic events. XO activity in plasma of northern elephant seals has been reported during prolonged fasting and rest and voluntary associated apneas. The objective of this study was to analyze circulating PNP and XO activities in marine mammals adapted to tolerate repeated cycles of ischemia/reperfusion associated with diving (bottlenose dolphin, northern elephant seal) in comparison with semiaquatic (river otter) and terrestrial mammals (human, pig). PNP activities in plasma and erythrocytes, as well as XO activity in plasma, from all species were quantified by spectrophotometry. No clear relationship in circulating PNP or XO activity could be established between marine, semiaquatic and terrestrial mammals. Erythrocytes from bottlenose dolphins and humans are highly permeable to nucleosides and glucose, intraerythrocyte PNP activity may be related to a release of purine nucleotides from the liver. High-energy costs will probably mean a higher ATP degradation rate in river otters, as compared to northern elephant seals or dolphins. Lower erythrocyte PNP activity and elevated plasma XO activity in northern elephant seal could be associated with fasting and/or sleep- and dive-associated apneas. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Redox Stimulation of Human THP-1 Monocytes in Response to Cold Physical Plasma.

    PubMed

    Bekeschus, Sander; Schmidt, Anke; Bethge, Lydia; Masur, Kai; von Woedtke, Thomas; Hasse, Sybille; Wende, Kristian

    2016-01-01

    In plasma medicine, cold physical plasma delivers a delicate mixture of reactive components to cells and tissues. Recent studies suggested a beneficial role of cold plasma in wound healing. Yet, the biological processes related to the redox modulation via plasma are not fully understood. We here used the monocytic cell line THP-1 as a model to test their response to cold plasma in vitro. Intriguingly, short term plasma treatment stimulated cell growth. Longer exposure only modestly compromised cell viability but apparently supported the growth of cells that were enlarged in size and that showed enhanced metabolic activity. A significantly increased mitochondrial content in plasma treated cells supported this notion. On THP-1 cell proteome level, we identified an increase of protein translation with key regulatory proteins being involved in redox regulation (hypoxia inducible factor 2α), differentiation (retinoic acid signaling and interferon inducible factors), and cell growth (Yin Yang 1). Regulation of inflammation is a key element in many chronic diseases, and we found a significantly increased expression of the anti-inflammatory heme oxygenase 1 (HMOX1) and of the neutrophil attractant chemokine interleukin-8 (IL-8). Together, these results foster the view that cold physical plasma modulates the redox balance and inflammatory processes in wound related cells.

  14. Determination of N-(trans-4-isopropylcyclohexanecarbonyl)-D-phenylalanine and its metabolites in human plasma and urine by column-switching high-performance liquid chromatography with ultraviolet detection.

    PubMed

    Ono, I; Matsuda, K; Kanno, S

    1997-05-09

    A simple, rapid and sensitive two column-switching high-performance liquid chromatographic (HPLC) method with ultraviolet detection at 210 nm has been developed for the determination of N-(trans-4-isopropylcyclohexanecarbonyl)-D-phenylalanine (AY4166, I) and its seven metabolites in human plasma and urine. Measurements of I and its metabolites were carried out by two column-switching HPLC, because metabolites were classified into two groups according to their retention times. After purification of plasma samples using solid-phase extraction and direct dilution of urinary samples, I and each metabolite were injected into HPLC. The calibration graphs for plasma and urinary samples were linear in the ranges 0.1 to 10 microg ml(-1) and 0.5 to 50 microg ml(-1), respectively. Recoveries of I and its seven metabolites were over 88% by the standard addition method and the relative standard deviations of I and its metabolites were 1-6%.

  15. Study of the plasma proteome of Atlantic cod (Gadus morhua): Effect of exposure to two PAHs and their corresponding diols.

    PubMed

    Skogland Enerstvedt, Karianne; Sydnes, Magne O; Pampanin, Daniela M

    2017-09-01

    Occurrence of polycyclic aromatic hydrocarbon (PAH) contamination in the marine environment represents a risk to marine life and humans. In this study, plasma samples from Atlantic cod (Gadus morhua) were analysed by shotgun mass spectrometry to investigate the plasma proteome in response to exposure to single PAHs (naphthalene or chrysene) and their corresponding metabolites (dihydrodiols). In total, 369 proteins were identified and ranked according to their relative abundance. The levels of 12 proteins were found significantly altered in PAH exposed fish and are proposed as new biomarker candidates. Eleven proteins were upregulated, primarily immunoglobulin components, and one protein was downregulated (antifreeze protein type IV.) The uniformity of the upregulated proteins suggests a triggered immune response in the exposed fish. Overall, the results provide valuable knowledge for future studies of the Atlantic cod plasma proteome and generate grounds for establishing new plasma protein biomarkers for environmental monitoring of PAH related exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Plasma Protein Oxidation and Its Correlation with Antioxidant Potential During Human Aging

    PubMed Central

    Pandey, Kanti Bhooshan; Mehdi, Mohd Murtaza; Maurya, Pawan Kumar; Rizvi, Syed Ibrahim

    2010-01-01

    Previous studies have indicated that the main molecular characteristic of aging is the progressive accumulation of oxidative damages in cellular macromolecules. Proteins are one of the main molecular targets of age-related oxidative stress, which have been observed during aging process in cellular systems. Reactive oxygen species (ROS) can lead to oxidation of amino acid side chains, formation of protein-protein cross-linkages, and oxidation of the peptide backbones. In the present study, we report the age-dependent oxidative alterations in biomarkers of plasma protein oxidation: protein carbonyls (PCO), advanced oxidation protein products (AOPPs) and plasma total thiol groups (T-SH) in the Indian population and also correlate these parameters with total plasma antioxidant potential. We show an age dependent decrease in T-SH levels and increase in PCO and AOPPs level. The alterations in the levels of these parameters correlated significantly with the total antioxidant capacity of the plasma. The levels of oxidized proteins in plasma provide an excellent biomarker of oxidative stress due to the relative long half-life of such oxidized proteins. PMID:20826915

  17. Cytochrome P450 dependent metabolism of the new designer drug 1-(3-trifluoromethylphenyl)piperazine (TFMPP). In vivo studies in Wistar and Dark Agouti rats as well as in vitro studies in human liver microsomes.

    PubMed

    Staack, Roland F; Paul, Liane D; Springer, Dietmar; Kraemer, Thomas; Maurer, Hans H

    2004-01-15

    1-(3-Trifluoromethylphenyl)piperazine (TFMPP) is a designer drug with serotonergic properties. Previous studies with male Wistar rats (WI) had shown, that TFMPP was metabolized mainly by aromatic hydroxylation. In the current study, it was examined whether this reaction may be catalyzed by cytochrome P450 (CYP)2D6 by comparing TFMPP vs. hydroxy TFMPP ratios in urine from female Dark Agouti rats, a model of the human CYP2D6 poor metabolizer phenotype (PM), male Dark Agouti rats, an intermediate model, and WI, a model of the human CYP2D6 extensive metabolizer phenotype. Furthermore, the human hepatic CYPs involved in TFMPP hydroxylation were identified using cDNA-expressed CYPs and human liver microsomes. Finally, TFMPP plasma levels in the above mentioned rats were compared. The urine studies suggested that TFMPP hydroxylation might be catalyzed by CYP2D6 in humans. Studies using human CYPs showed that CYP1A2, CYP2D6 and CYP3A4 catalyzed TFMPP hydroxylation, with CYP2D6 being the most important enzyme accounting for about 81% of the net intrinsic clearance, calculated using the relative activity factor approach. The hydroxylation was significantly inhibited by quinidine (77%) and metabolite formation in poor metabolizer genotype human liver microsomes was significantly lower (63%) compared to pooled human liver microsomes. Analysis of the plasma samples showed that female Dark Agouti rats exhibited significantly higher TFMPP plasma levels compared to those of male Dark Agouti rats and WI. Furthermore, pretreatment of WI with the CYP2D inhibitor quinine resulted in significantly higher TFMPP plasma levels. In conclusion, the presented data give hints for possible differences in pharmacokinetics in human PM and human CYP2D6 extensive metabolizer phenotype subjects relevant for risk assessment.

  18. Mortality Benefit of Recombinant Human Interleukin-1 Receptor Antagonist for Sepsis Varies by Initial Interleukin-1 Receptor Antagonist Plasma Concentration.

    PubMed

    Meyer, Nuala J; Reilly, John P; Anderson, Brian J; Palakshappa, Jessica A; Jones, Tiffanie K; Dunn, Thomas G; Shashaty, Michael G S; Feng, Rui; Christie, Jason D; Opal, Steven M

    2018-01-01

    Plasma interleukin-1 beta may influence sepsis mortality, yet recombinant human interleukin-1 receptor antagonist did not reduce mortality in randomized trials. We tested for heterogeneity in the treatment effect of recombinant human interleukin-1 receptor antagonist by baseline plasma interleukin-1 beta or interleukin-1 receptor antagonist concentration. Retrospective subgroup analysis of randomized controlled trial. Multicenter North American and European clinical trial. Five hundred twenty-nine subjects with sepsis and hypotension or hypoperfusion, representing 59% of the original trial population. Random assignment of placebo or recombinant human interleukin-1 receptor antagonist × 72 hours. We measured prerandomization plasma interleukin-1 beta and interleukin-1 receptor antagonist and tested for statistical interaction between recombinant human interleukin-1 receptor antagonist treatment and baseline plasma interleukin-1 receptor antagonist or interleukin-1 beta concentration on 28-day mortality. There was significant heterogeneity in the effect of recombinant human interleukin-1 receptor antagonist treatment by plasma interleukin-1 receptor antagonist concentration whether plasma interleukin-1 receptor antagonist was divided into deciles (interaction p = 0.046) or dichotomized (interaction p = 0.028). Interaction remained present across different predicted mortality levels. Among subjects with baseline plasma interleukin-1 receptor antagonist above 2,071 pg/mL (n = 283), recombinant human interleukin-1 receptor antagonist therapy reduced adjusted mortality from 45.4% to 34.3% (adjusted risk difference, -0.12; 95% CI, -0.23 to -0.01), p = 0.044. Mortality in subjects with plasma interleukin-1 receptor antagonist below 2,071 pg/mL was not reduced by recombinant human interleukin-1 receptor antagonist (adjusted risk difference, +0.07; 95% CI, -0.04 to +0.17), p = 0.230. Interaction between plasma interleukin-1 beta concentration and recombinant human interleukin-1 receptor antagonist treatment was not statistically significant. We report a heterogeneous effect of recombinant human interleukin-1 receptor antagonist on 28-day sepsis mortality that is potentially predictable by plasma interleukin-1 receptor antagonist in one trial. A precision clinical trial of recombinant human interleukin-1 receptor antagonist targeted to septic patients with high plasma interleukin-1 receptor antagonist may be worthy of consideration.

  19. 21 CFR 640.91 - Processing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.91 Processing. (a) Date... °C or colder. (e) Heat treatment. Heating of the final containers of Plasma Protein Fraction (Human... concentration of the product. (g) Incubation. All final containers of Plasma Protein Fraction (Human) shall be...

  20. 21 CFR 640.91 - Processing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.91 Processing. (a) Date... °C or colder. (e) Heat treatment. Heating of the final containers of Plasma Protein Fraction (Human... concentration of the product. (g) Incubation. All final containers of Plasma Protein Fraction (Human) shall be...

  1. 21 CFR 640.91 - Processing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.91 Processing. (a) Date... °C or colder. (e) Heat treatment. Heating of the final containers of Plasma Protein Fraction (Human... concentration of the product. (g) Incubation. All final containers of Plasma Protein Fraction (Human) shall be...

  2. 21 CFR 640.91 - Processing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.91 Processing. (a) Date... °C or colder. (e) Heat treatment. Heating of the final containers of Plasma Protein Fraction (Human... concentration of the product. (g) Incubation. All final containers of Plasma Protein Fraction (Human) shall be...

  3. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    PubMed

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of <12%. Using isobaric tags for relative and absolute quantitation (iTRAQ) 4-plex, >4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  4. Prediction of a Therapeutic Dose for Buagafuran, a Potent Anxiolytic Agent by Physiologically Based Pharmacokinetic/Pharmacodynamic Modeling Starting from Pharmacokinetics in Rats and Human.

    PubMed

    Yang, Fen; Wang, Baolian; Liu, Zhihao; Xia, Xuejun; Wang, Weijun; Yin, Dali; Sheng, Li; Li, Yan

    2017-01-01

    Physiologically based pharmacokinetic (PBPK)/pharmacodynamic (PD) models can contribute to animal-to-human extrapolation and therapeutic dose predictions. Buagafuran is a novel anxiolytic agent and phase I clinical trials of buagafuran have been completed. In this paper, a potentially effective dose for buagafuran of 30 mg t.i.d. in human was estimated based on the human brain concentration predicted by a PBPK/PD modeling. The software GastroPlus TM was used to build the PBPK/PD model for buagafuran in rat which related the brain tissue concentrations of buagafuran and the times of animals entering the open arms in the pharmacological model of elevated plus-maze. Buagafuran concentrations in human plasma were fitted and brain tissue concentrations were predicted by using a human PBPK model in which the predicted plasma profiles were in good agreement with observations. The results provided supportive data for the rational use of buagafuran in clinic.

  5. Pairwise alignment of chromatograms using an extended Fisher-Rao metric.

    PubMed

    Wallace, W E; Srivastava, A; Telu, K H; Simón-Manso, Y

    2014-09-02

    A conceptually new approach for aligning chromatograms is introduced and applied to examples of metabolite identification in human blood plasma by liquid chromatography-mass spectrometry (LC-MS). A square-root representation of the chromatogram's derivative coupled with an extended Fisher-Rao metric enables the computation of relative differences between chromatograms. Minimization of these differences using a common dynamic programming algorithm brings the chromatograms into alignment. Application to a complex sample, National Institute of Standards and Technology (NIST) Standard Reference Material 1950, Metabolites in Human Plasma, analyzed by two different LC-MS methods having significantly different ranges of elution time is described. Published by Elsevier B.V.

  6. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  7. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  8. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  9. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  10. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  11. Human soluble phospholipase A2 receptor is an inhibitor of the integrin-mediated cell migratory response to collagen-I.

    PubMed

    Watanabe, Kazunori; Watanabe, Kazuhiro; Watanabe, Yosuke; Fujioka, Daisuke; Nakamura, Takamitsu; Nakamura, Kazuto; Obata, Jun-Ei; Kugiyama, Kiyotaka

    2018-05-23

    Murine membrane-bound phospholipase A 2 receptor 1 (PLA 2 R) is shed and released into plasma in a soluble form that retains all of the extracellular domains. Relatively little is known about human PLA 2 R. This study examined whether human soluble PLA 2 R may have biological functions and whether soluble PLA 2 R may exist in human plasma. Here, we showed that human recombinant soluble PLA 2 R (rsPLA 2 R) bound to collagen-I and inhibited interaction of collagen-I with the extracellular domain of integrin β1 on the cell surface of HEK293 cells. As a result, rsPLA 2 R suppressed integrin β1-mediated migratory responses of HEK293 cells to collagen-I in Boyden chamber experiments. Inhibition of phosphorylation of FAK Tyr397 was also observed. Similar results were obtained with experiments using soluble PLA 2 R released from HEK293 cells transfected with a construct encoding human soluble PLA 2 R. rsPLA 2 R lacking the fibronectin-like type II (FNII) domain had no inhibitory effects on cell responses to collagen-I, suggesting an important role of the FNII domain in the interaction of rsPLA 2 R with collagen-I. In addition, rsPLA 2 R suppressed the migratory response to collagen-IV and binding of collagen-IV to the cell surface of human podocytes that endogenously express membrane-bound full-length PLA 2 R. Immunoprecipitation and Western blotting showed the existence of immuno-reactive PLA 2 R in human plasma. In conclusion, human recombinant soluble PLA 2 R inhibits integrin β1-mediated cell responses to collagens. Further studies are warranted to elucidate whether immuno-reactive PLA 2 R in human plasma has the same properties as rsPLA 2 R.

  12. Estradiol causes the rapid accumulation of cAMP in human prostate.

    PubMed Central

    Nakhla, A M; Khan, M S; Romas, N P; Rosner, W

    1994-01-01

    Androgens are widely acknowledged to be central to the pathogenesis of benign prostatic hypertrophy (BPH). However, BPH increases in prevalence as men age, at precisely the stage of life when plasma androgens are decreasing. The decrease in total plasma androgens is amplified by an age-related increase in plasma sex hormone-binding globulin (SHBG) that results in a relatively greater decrease in free androgens than in total androgens. In addition, estrogens have long been suspected to be important in BPH, but a direct effect on the human prostate has never been demonstrated. We present data that are consistent with a role for estradiol, and for a decrease in androgens and an increase in SHBG, in the pathogenesis of BPH. We show that estradiol, but not dihydrotestosterone, acts in concert with SHBG to produce an 8-fold increase in intracellular cAMP in human BPH tissue. This increase is not blocked by an antiestrogen and is not provoked by an estrogen (diethylstilbestrol) that does not bind to SHBG, thus excluding the classic estrogen receptor as being operative in these events. Conversely, dihydrotestosterone, which blocks the binding of estradiol to SHBG, completely negates the effect of estradiol. Finally, we demonstrate that the SHBG-steroid-responsive second-messenger system is primarily localized to the prostatic stromal cells and not to the prostatic epithelial cells. Thus, we have shown a cell-specific, powerful, nontranscriptional effect of estradiol on the human prostate. PMID:7515502

  13. Changes in the biomechanical properties of a single cell induced by nonthermal atmospheric pressure micro-dielectric barrier discharge plasma.

    PubMed

    Choi, Hyeongwon; Choi, Eun Ha; Kim, Kyung Sook

    2017-10-01

    Mechanical properties of a single cell are closely related to the fate and functions of the cell. Changes in mechanical properties may cause diseases or cell apoptosis. Selective cytotoxic effects of nonthermal atmospheric pressure micro-dielectric barrier discharge (DBD) plasma have been demonstrated on cancer cells. In this work, changes in the mechanical properties of a single cell induced by nonthermal atmospheric pressure micro-DBD plasma were investigated using atomic force microscopy (AFM). Two cervical cancer cell lines (HeLa and SiHa) and normal human fibroblast cells (HFBs) were exposed to micro-DBD plasma for various exposure times. The elasticity of a single cell was determined by force-distance curve measurement using AFM. Young's modulus was decreased by plasma treatment for all cells. The Young's modulus of plasma-treated HeLa cells was decreased by 75% compared to nontreated HeLa cells. In SiHa cells and HFBs, elasticity was decreased slightly. Chemical changes induced by the plasma treatment, which were observed by Raman spectroscopy, were also significant in HeLa cells compared to SiHa cells and HFBs. These results suggested that the molecular changes induced by micro-DBD plasma were related to cell mechanical changes. © 2017 Wiley Periodicals, Inc.

  14. A review of three stand-alone topical thrombins for surgical hemostasis.

    PubMed

    Cheng, Christine M; Meyer-Massetti, Carla; Kayser, Steven R

    2009-01-01

    Topical thrombins are active hemostatic agents that can be used to minimize blood loss during surgery. Before 2007, the only topical thrombins available were derived from bovine plasma. Antibody formation to bovine thrombin and/or factor V, with subsequent risk of cross-reactivity with human factor V, and hemorrhagic complications associated with human factor-V deficiencies have been described in case reports of surgeries in which bovine thrombins were used. This risk is now included in the boxed warning section of the bovine thrombin prescribing information. In 2007 and 2008, 2 new topical thrombins from nonbovine sources received approval for use from the US Food and Drug Administration. The 3 active topical thrombins that are currently marketed are bovine plasma-derived thrombin, human plasma-derived thrombin, and human recombinant thrombin. The purpose of this review was to evaluate the literature on the efficacy and safety of topical thrombins and discuss the pharmacoeconomic considerations associated with their use. PubMed, EMBASE, and International Pharmaceutical Abstracts were searched for relevant papers published in English through October 10,2008, using the terms thrombin, human recombinant thrombin, bovine thrombin, plasma derived thrombin, and topical thrombin. Manufacturer-provided materials were also reviewed. Abstracts and unpublished data, as well as evaluations of sealants, adhesives, glues, and other hemostats that contain thrombin mixed with fibrinogen and other clotting factors, were excluded. Four randomized, double-blind studies involving the active, stand-alone topical thrombins were found. The bovine thrombin involved in these studies was the predecessor to the currently marketed, highly purified bovine formulation. No studies comparing the human products, studies involving the highly purified bovine preparation, or placebo-controlled studies involving bovine thrombin were found. In a Phase III comparison of human recombinant thrombin and bovine thrombin, the percentages of patients who achieved hemostasis within 10 minutes of topical thrombin application were 95.4% and 95.1%, respectively (95% CI, -3.7 to 5.0). The incidence of hemostasis within 10 minutes was also similar in a Phase III comparison of human plasma-derived thrombin and bovine thrombin (both, 97.4% [95% CI, 0.96 to 1.05]). In the study that compared human recombinant and bovine thrombin, the incidence of antiproduct antibody formation was 21.5% (43/200) in the bovine thrombin group and 1.5% (3/198) in the human recombinant thrombin group (P < 0.001); patients with antibodies to bovine thrombin had numerically higher incidences of bleeding or thromboembolic events than did patients without these antibodies (19% vs 13%; P value not reported). Human plasma-derived thrombin is available as a frozen sterile solution that must be thawed before application, whereas the human recombinant and bovine plasma-derived products are supplied as unrefrigerated sterile powders that must be reconstituted before use. The human thrombins are more costly than bovine thrombin on a per-vial basis. The average wholesale prices (US $, 2008) for 5000-IU vials of bovine thrombin and human recombinant thrombin were $87.85 and $103.20, respectively; the average wholesale price for a 4000- to 6000-IU vial of human plasma-derived thrombin was $96.00. Topical thrombins vary in the ways in which they are manufactured and their safety profiles, storage requirements, and costs. Human recombinant thrombin and human plasma-derived thrombin have each been shown to have hemostatic efficacy comparable to that of bovine thrombin. Bovine thrombin carries the risk of formation of cross-reactive antibodies to bovine thrombin, factor V, and other impurities that may be present in these formulations. Immunogenicity data for the currently marketed, highly purified bovine thrombin relative to older formulations of bovine thrombin could not be found. Whether the potential safety advantage justifies the added cost of the human products remains to be established.

  15. Studies of nontarget-mediated distribution of human full-length IgG1 antibody and its FAb fragment in cardiovascular and metabolic-related tissues.

    PubMed

    Davidsson, Pia; Söderling, Ann-Sofi; Svensson, Lena; Ahnmark, Andrea; Flodin, Christine; Wanag, Ewa; Screpanti-Sundqvist, Valentina; Gennemark, Peter

    2015-05-01

    Tissue distribution and pharmacokinetics (PK) of full-length nontargeted antibody and its antigen-binding fragment (FAb) were evaluated for a range of tissues primarily of interest for cardiovascular and metabolic diseases. Mice were intravenously injected with a dose of 10 mg/kg of either human IgG1or its FAb fragment; perfused tissues were collected at a range of time points over 3 weeks for the human IgG1 antibody and 1 week for the human FAb antibody. Tissues were homogenized and antibody concentrations were measured by specific immunoassays on the Gyros system. Exposure in terms of maximum concentration (Cmax ) and area under the curve was assessed for all nine tissues. Tissue exposure of full-length antibody relative to plasma exposure was found to be between 1% and 10%, except for brain (0.2%). Relative concentrations of FAb antibody were the same, except for kidney tissue, where the antibody concentration was found to be ten times higher than in plasma. However, the absolute tissue uptake of full-length IgG was significantly higher than the absolute tissue uptake of the FAb antibody. This study provides a reference PK state for full-length whole and FAb antibodies in tissues related to cardiovascular and metabolic diseases that do not include antigen or antibody binding. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  16. Comparative thermometric coagulation studies of plasmas from normal outbred Swiss Webster mice and persons.

    PubMed

    Tsang, V C; Wyatt, C R; Damian, R T

    1979-06-01

    The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.

  17. High-throughput sequencing of human plasma RNA by using thermostable group II intron reverse transcriptases

    PubMed Central

    Qin, Yidan; Yao, Jun; Wu, Douglas C.; Nottingham, Ryan M.; Mohr, Sabine; Hunicke-Smith, Scott; Lambowitz, Alan M.

    2016-01-01

    Next-generation RNA-sequencing (RNA-seq) has revolutionized transcriptome profiling, gene expression analysis, and RNA-based diagnostics. Here, we developed a new RNA-seq method that exploits thermostable group II intron reverse transcriptases (TGIRTs) and used it to profile human plasma RNAs. TGIRTs have higher thermostability, processivity, and fidelity than conventional reverse transcriptases, plus a novel template-switching activity that can efficiently attach RNA-seq adapters to target RNA sequences without RNA ligation. The new TGIRT-seq method enabled construction of RNA-seq libraries from <1 ng of plasma RNA in <5 h. TGIRT-seq of RNA in 1-mL plasma samples from a healthy individual revealed RNA fragments mapping to a diverse population of protein-coding gene and long ncRNAs, which are enriched in intron and antisense sequences, as well as nearly all known classes of small ncRNAs, some of which have never before been seen in plasma. Surprisingly, many of the small ncRNA species were present as full-length transcripts, suggesting that they are protected from plasma RNases in ribonucleoprotein (RNP) complexes and/or exosomes. This TGIRT-seq method is readily adaptable for profiling of whole-cell, exosomal, and miRNAs, and for related procedures, such as HITS-CLIP and ribosome profiling. PMID:26554030

  18. Cerebrospinal fluid and plasma oxytocin concentrations are positively correlated and negatively predict anxiety in children.

    PubMed

    Carson, D S; Berquist, S W; Trujillo, T H; Garner, J P; Hannah, S L; Hyde, S A; Sumiyoshi, R D; Jackson, L P; Moss, J K; Strehlow, M C; Cheshier, S H; Partap, S; Hardan, A Y; Parker, K J

    2015-09-01

    The neuropeptide oxytocin (OXT) exerts anxiolytic and prosocial effects in the central nervous system of rodents. A number of recent studies have attempted to translate these findings by investigating the relationships between peripheral (e.g., blood, urinary and salivary) OXT concentrations and behavioral functioning in humans. Although peripheral samples are easy to obtain in humans, whether peripheral OXT measures are functionally related to central OXT activity remains unclear. To investigate a possible relationship, we quantified OXT concentrations in concomitantly collected cerebrospinal fluid (CSF) and blood samples from child and adult patients undergoing clinically indicated lumbar punctures or other CSF-related procedures. Anxiety scores were obtained in a subset of child participants whose parents completed psychometric assessments. Findings from this study indicate that plasma OXT concentrations significantly and positively predict CSF OXT concentrations (r=0.56, P=0.0064, N=27). Moreover, both plasma (r=-0.92, P=0.0262, N=10) and CSF (r=-0.91, P=0.0335, N=10) OXT concentrations significantly and negatively predicted trait anxiety scores, consistent with the preclinical literature. Importantly, plasma OXT concentrations significantly and positively (r=0.96, P=0.0115, N=10) predicted CSF OXT concentrations in the subset of child participants who provided behavioral data. This study provides the first empirical support for the use of blood measures of OXT as a surrogate for central OXT activity, validated in the context of behavioral functioning. These preliminary findings also suggest that impaired OXT signaling may be a biomarker of anxiety in humans, and a potential target for therapeutic development in individuals with anxiety disorders.

  19. Online restricted-access material combined with high-performance liquid chromatography and tandem mass spectrometry for the simultaneous determination of vanillin and its vanillic acid metabolite in human plasma.

    PubMed

    Li, De-Qiang; Zhang, Zhi-Qing; Yang, Xiu-Ling; Zhou, Chun-Hua; Qi, Jin-Long

    2016-09-01

    An automated online solid-phase extraction with restricted-access material combined with high-performance liquid chromatography and tandem mass spectrometry was developed and validated for the simultaneous quantification of vanillin and its vanillic acid metabolite in human plasma. After protein precipitation by methanol, which contained the internal standards, the supernatant of plasma samples was injected to the system, the endogenous large molecules were flushed out, and target analytes were trapped and enriched on the adsorbent, resulting in a minimization of sample complexity and ion suppression effects. Calibration curves were linear over the concentrations of 5-1000 ng/mL for vanillin and 10-5000 ng/mL for vanillic acid with a coefficient of determination >0.999 for the determined compounds. The lower limits of quantification of vanillin and vanillic acid were 5.0 and 10.0 ng/mL, respectively. The intra- and inter-run precisions expressed as the relative standard deviation were 2.6-8.6 and 3.2-10.2%, respectively, and the accuracies expressed as the relative error were in the range of -6.1 to 7.3%. Extraction recoveries of analytes were between 89.5 and 97.4%. There was no notable matrix effect for any analyte concentration. The developed method was proved to be sensitive, repeatable, and accurate for the quantification of vanillin and its vanillic acid metabolite in human plasma. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Lack of species-specific difference in pulmonary function when using mouse versus human plasma in a mouse model of hemorrhagic shock.

    PubMed

    Peng, Zhanglong; Pati, Shibani; Fontaine, Magali J; Hall, Kelly; Herrera, Anthony V; Kozar, Rosemary A

    2016-11-01

    Clinical studies have demonstrated that the early and empiric use of plasma improves survival after hemorrhagic shock. We have demonstrated in rodent models of hemorrhagic shock that resuscitation with plasma is protective to the lungs compared with lactated Ringer's solution. As our long-term objective is to determine the molecular mechanisms that modulate plasma's protective effects in injured bleeding patients, we have used human plasma in a mouse model of hemorrhagic shock. The goal of the current experiments is to determine if there are significant adverse effects on lung injury when using human versus mouse plasma in an established murine model of hemorrhagic shock and laparotomy. Mice underwent laparotomy and 90 minutes of hemorrhagic shock to a mean arterial pressure (MAP) of 35 ± 5 mm Hg followed by resuscitation at 1× shed blood using either mouse fresh frozen plasma (FFP), human FFP, or human lyophilized plasma. Mean arterial pressure was recorded during shock and for the first 30 minutes of resuscitation. After 3 hours, animals were killed, and lungs collected for analysis. There was a significant increase in early MAP when mouse FFP was used to resuscitate animals compared with human FFP or human lyophilized plasma. However, despite these differences, analysis of the mouse lungs revealed no significant differences in pulmonary histopathology, lung permeability, or lung edema between all three plasma groups. Analysis of neutrophil infiltration in the lungs revealed that mouse FFP decreased neutrophil influx as measured by neutrophil staining; however, myeloperoxidase immunostaining revealed no significant differences in between groups. The study of human plasma in a mouse model of hemorrhagic shock is feasible but does reveal some differences compared with mouse plasma-based resuscitation in physiologic measures such as MAP postresuscitation. Measures of end organ function such as lung injury appear to be comparable in this acute model of hemorrhagic shock and resuscitation.

  1. Fibulin-1 purification from human plasma using affinity chromatography on Factor H-Sepharose

    PubMed Central

    DiScipio, Richard G.; Liddington, Robert C.; Schraufstatter, Ingrid U.

    2016-01-01

    A method is reported to purify Fibulin-1 from human plasma resulting in a 36% recovery. The steps involve removal of the cryoglobulin and the vitamin K dependent proteins followed by polyethylene glycol and ammonium sulfate precipitations, DEAE-Sephadex column chromatography and finally Factor H-Sepharose affinity purification. The procedure is designed to be integrated into an overall scheme for the isolation of over 30 plasma proteins from a single batch of human plasma. Results from mass spectroscopy, SDS-PAGE, and Western blotting indicate that human plasma Fibulin-1 is a single chain of the largest isotype. Functional binding assays demonstrated calcium ion dependent interaction of Fibulin-1 for fibrinogen, fibronectin, and Factor H. The procedure described is the first to our knowledge that enables a large scale purification of Fibulin-1 from human plasma. PMID:26826315

  2. False-positive pregnancy test after transfusion of solvent/detergent-treated plasma.

    PubMed

    Jilma-Stohlawetz, Petra; Wreford-Bush, Tim; Mills, Francesca; Davidson, Fiona; Kursten, Friedrich W; Jilma, Bernd; Birchall, Janet

    2017-12-01

    The transmission of pathogens, antibodies, and proteins is a possible consequence of blood product transfusion. A female patient had an unexpected positive serum β-human chorionic gonadotropin result, indicative of pregnancy, after she had received a transfusion with 1 unit of platelet concentrate, 4 units of red blood cells, and 4 units of pooled solvent/detergent-treated plasma (Octaplas). To investigate the possibility of passive transfusion of β-human chorionic gonadotropin from the plasma transfusion, one additional unit from the same batch was thawed and analyzed. To validate the β-human chorionic gonadotropin assay for use in solvent/detergent-treated plasma and to investigate any interference in the assay, dilution experiments were performed using the implicated plasma batch diluted with male and non-pregnant female sera. Also, plasma from a known pregnant woman was diluted with Octaplas (tested negative for β-human chorionic gonadotropin) and with a male serum to validate the assay for use in solvent/detergent-treated plasma. The implicated solvent/detergent-treated plasma had a mean β-human chorionic gonadotropin level of 91.5 mIU/mL. Results from the dilution experiments revealed an excellent correlation (r > 0.99) between β-human chorionic gonadotropin measurement in solvent/detergent-treated plasma and male serum and no over or under recovery of the expected results. Further measurements of β-human chorionic gonadotropin levels in the female recipient revealed an estimated half-life of 6 hours. This case demonstrates the importance of considering the possibility of passive transmission of analytes to a patient from the transfusion of blood products. Furthermore, the measurement of β-human chorionic gonadotropin is valid in solvent/detergent-treated plasma using a Roche Cobas analyzer. © 2017 AABB.

  3. Genetics of Lipid and Lipoprotein Disorders and Traits.

    PubMed

    Dron, Jacqueline S; Hegele, Robert A

    2016-01-01

    Plasma lipids, namely cholesterol and triglyceride, and lipoproteins, such as low-density lipoprotein (LDL) and high-density lipoprotein, serve numerous physiological roles. Perturbed levels of these traits underlie monogenic dyslipidemias, a diverse group of multisystem disorders. We are on the verge of having a relatively complete picture of the human dyslipidemias and their components. Recent advances in genetics of plasma lipids and lipoproteins include the following: (1) expanding the range of genes causing monogenic dyslipidemias, particularly elevated LDL cholesterol; (2) appreciating the role of polygenic effects in such traits as familial hypercholesterolemia and combined hyperlipidemia; (3) accumulating a list of common variants that determine plasma lipids and lipoproteins; (4) applying exome sequencing to identify collections of rare variants determining plasma lipids and lipoproteins that via Mendelian randomization have also implicated gene products such as NPC1L1 , APOC3 , LDLR , APOA5 , and ANGPTL4 as causal for atherosclerotic cardiovascular disease; and (5) using naturally occurring genetic variation to identify new drug targets, including inhibitors of apolipoprotein (apo) C-III, apo(a), ANGPTL3, and ANGPTL4. Here, we compile this disparate range of data linking human genetic variation to plasma lipids and lipoproteins, providing a "one stop shop" for the interested reader.

  4. Analysis of cyclophosphamide and carboxyethylphosphoramide mustard enantiomers in human plasma and application to clinical pharmacokinetics.

    PubMed

    Attié de Castro, Francine; Scatena, Gabriel dos Santos; Cass, Quézia Bezerra; Simões, Belinda Pinto; Lanchote, Vera Lucia

    2014-11-15

    This study describes for the first time a method for the sequential analysis of the enantiomers of cyclophosphamide (CY) and its metabolite carboxyethylphosphoramide mustard (CEPM) in human plasma. The CY and CEPM enantiomers were extracted from plasma using only ethyl acetate and separated on a Chiralpak(®) AD-RH column using a mixture of water:acetonitrile:ethanol (45:30:25, v/v/v) plus 0.1% trifluoroacetic acid as the mobile phase at a flow rate of 0.5mL/min. No matrix effect was observed in the analysis of the enantiomers of both analytes and the analytical method was linear in the range of 0.05-25.0μg and 250-1000ng of each enantiomer/mL plasma. The coefficients of variation and relative errors obtained for the assessment of intra- and interassay precision and accuracy were less than 15%. CY and CEPM were found to be stable in human plasma after three successive freeze/thaw cycles, during storage for 4h at room temperature, and after 24h inside the autosampler at 4°C, with deviations less than 15%. The method was applied to the study of the pharmacokinetics of CY and its metabolite CEPM in patients with multiple sclerosis (n=10) who received a CY pretransplant conditioning regimen for hematopoietic stem cell transplantation. The pharmacokinetic parameters showed plasma accumulation of the (S)-(-)-CY enantiomer (S/R ratio=1.3) and lack of enantioselective exposure to the CEPM metabolite (S/R ratio=1.0). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Quantitative determination of dopamine in human plasma by a highly sensitive LC-MS/MS assay: Application in preterm neonates.

    PubMed

    Zhang, Daping; Wu, Lei; Chow, Diana S-L; Tam, Vincent H; Rios, Danielle R

    2016-01-05

    The determination of dopamine facilitates better understanding of the complex brain disorders in the central nervous system and the regulation of endocrine system, cardiovascular functions and renal functions in the periphery. The purpose of this study was to develop a highly sensitive and reliable assay for the quantification of dopamine in human neonate plasma. Dopamine was extracted from human plasma by strong cation exchange (SCX) solid phase extraction (SPE), and subsequently derivatized with propionic anhydride. The derivatized analyte was separated by a Waters Acquity UPLC BEH C18 column using gradient elution at 0.4 ml/min with mobile phases A (0.2% formic acid in water [v/v]) and B (MeOH-ACN [v/v, 30:70]). Analysis was performed under positive electrospray ionization tandem mass spectrometer (ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The stable and relatively non-polar nature of the derivatized analyte enables reliable quantification of dopamine in the range of 10-1000 pg/ml using 200 μl of plasma sample. The method was validated with intra-day and inter-day precision less than 7%, and the intra-day and inter-day accuracy of 91.9-101.9% and 92.3-102.6%, respectively. The validated assay was applied to quantify dopamine levels in two preterm neonate plasma samples. In conclusion, a sensitive and selective LC-MS/MS method has been developed and validated, and successfully used for the determination of plasma dopamine levels in preterm neonates. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Calcitonin gene-related peptide and somatostatin releases correlated with the area under the lafutidine concentration-time curve in human plasma.

    PubMed

    Ikawa, K; Shimatani, T; Azuma, Y; Inoue, M; Morikawa, N

    2006-08-01

    To examine the effects of the histamine H(2)-receptor antagonist, lafutidine, at clinical dosage (10 mg tablet after a standardized meal) on plasma levels of the gastrointestinal peptides, calcitonin gene-related peptide (CGRP), somatostatin and gastrin. Six healthy male volunteers ate a standardized meal, and received either lafutidine orally at a dose of 10 mg or water only (control). Blood samples were taken before and up to 4 h after the drug administration. Plasma lafutidine concentrations were determined by high pressure liquid chromatography. Pharmacokinetic analysis of lafutidine was performed using one-compartmental model. The levels of immunoreactive substances of plasma CGRP, somatostatin and gastrin were measured by enzyme immunoassay, and the amount of peptide release was calculated by the trapezoidal method. Lafutidine significantly increased plasma CGRP levels at 1, 1.5, 2.5 and 4 h and the total amount of CGRP release (192 +/- 14.0 pg.h/mL) compared with the control group (128 +/- 21.5 pg.h/mL). Lafutidine significantly increased the plasma somatostatin levels at 1 and 1.5 h, and the total amount of somatostatin released (107 +/- 18.2 pg.h/mL) compared with the control (78.4 +/- 7.70 pg.h/mL). The area under the drug concentration-time curve (AUC) from 0 to 4 h after administration correlated well with the Delta-CGRP and Delta-somatostatin release but not with total amount of gastrin released. However, plasma gastrin levels were significantly elevated at 1.5 h after drug administration. Lafutidine at clinical dosage increases plasma CGRP and the somatostatin. The amounts released correlated with the AUC of lafutidine in humans. These results suggest that the increased release of CGRP and somatostatin may contribute to its gastroprotective and anti-acid secretory effect.

  7. Comparative lytic efficacy of rt-PA and ultrasound in porcine versus human clots.

    PubMed

    Huang, Shenwen; Shekhar, Himanshu; Holland, Christy K

    2017-01-01

    Porcine thrombi are employed routinely in preclinical models of ischemic stroke. In this study, we examined the differential lytic susceptibility of porcine and human whole blood clots with and without the use of microbubbles and ultrasound (US) as an adjuvant. An in vitro system equipped with time-lapse microscopy was used to evaluate recombinant tissue-plasminogen activator (rt-PA) lysis of porcine and human clots in the same species or cross species plasma. Human and porcine whole blood clots were treated with rt-PA and an echo contrast agent, Definity®, and exposed to intermittent 120 kHz US. The rt-PA lytic efficacy observed for porcine clots in porcine plasma was 22 times lower than for human clots in human plasma reported previously. Further, porcine clots did not exhibit increased lysis with adjuvant Definity® and US exposure. However, the rt-PA lytic susceptibility of the porcine clots in human plasma was similar to that of human clots in human plasma. Human clots perfused with porcine plasma did not respond to rt-PA, but adjuvant use of Definity® and US enhanced lysis. These results reveal considerable differences in lytic susceptibility of porcine clots and human clots to rt-PA. The use of porcine clot models to test new human thrombolytic therapies may necessitate modulation of coagulation and thrombolytic factors to reflect human hemostasis accurately.

  8. Antioxidant capacity of human blood plasma and human urine: simultaneous evaluation of the ORAC index and ascorbic acid concentration employing pyrogallol red as probe.

    PubMed

    Torres, P; Galleguillos, P; Lissi, E; López-Alarcón, C

    2008-10-15

    The oxygen radical absorbance capacity (ORAC) methodology has been employed to estimate the antioxidant capacity of human blood plasma and human urine using pyrogallol red (ORAC-PGR) as target molecule. Uric acid, reduced glutathione, human serum albumin, and ascorbic acid (ASC) inhibited the consumption of pyrogallol red, but only ASC generated an induction time. Human blood plasma and human urine protected efficiently pyrogallol red. In these assays, both biological fluids generated neat induction times that were removed by ascorbate oxidase. From these results, ORAC-PGR method could be proposed as a simple alternative to evaluate an ORAC index and, simultaneously, to estimate the concentration of ascorbic acid in human blood plasma or human urine.

  9. Characterization of the Low-Molecular-Weight Human Plasma Peptidome.

    PubMed

    Greening, David W; Simpson, Richard J

    2017-01-01

    The human plasma proteome represents an important secreted sub-proteome. Proteomic analysis of blood plasma with mass spectrometry is a challenging task. The high complexity and wide dynamic range of proteins as well as the presence of several proteins at very high concentrations complicate the profiling of the human plasma proteome. The peptidome (or low-molecular-weight fraction, LMF) of the human plasma proteome is an invaluable source of biological information, especially in the context of identifying plasma-based markers of disease. Peptides are generated by active synthesis and proteolytic processing, often yielding proteolytic fragments that mediate a variety of physiological and pathological functions. As such, degradomic studies, investigating cleavage products via peptidomics and top-down proteomics in particular, have warranted significant research interest. However, due to their molecular weight, abundance, and solubility, issues with identifying specific cleavage sites and coverage of peptide fragments remain challenging. Peptidomics is currently focused toward comprehensively studying peptides cleaved from precursor proteins by endogenous proteases. This protocol outlines a standardized rapid and reproducible procedure for peptidomic profiling of human plasma using centrifugal ultrafiltration and mass spectrometry. Ultrafiltration is a convective process that uses anisotropic semipermeable membranes to separate macromolecular species on the basis of size. We have optimized centrifugal ultrafiltration (cellulose triacetate membrane) for plasma fractionation with respect to buffer and solvent composition, centrifugal force, duration, and temperature to facilitate recovery >95% and enrichment of the human plasma peptidome. This method serves as a comprehensive and facile process to enrich and identify a key, underrepresented sub-proteome of human blood plasma.

  10. 21 CFR 640.60 - Source Plasma.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  11. 21 CFR 640.60 - Source Plasma.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  12. 21 CFR 640.60 - Source Plasma.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  13. 21 CFR 640.60 - Source Plasma.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  14. The relationship of endogenous plasma concentrations of β-Hydroxy β-Methyl Butyrate (HMB) to age and total appendicular lean mass in humans.

    PubMed

    Kuriyan, Rebecca; Lokesh, Deepa P; Selvam, Sumithra; Jayakumar, J; Philip, Mamatha G; Shreeram, Sathyavageeswaran; Kurpad, Anura V

    2016-08-01

    The maintenance of muscle mass and muscle strength is important for reducing the risk of chronic diseases. The age- related loss of muscle mass and strength is associated with adverse outcomes of physical disability, frailty and death. β-Hydroxy β-Methyl Butyrate (HMB), a metabolite of leucine, has beneficial effects on muscle mass and strength under various catabolic conditions. The objectives of the present study were to determine if age- related differences existed in endogenous plasma HMB levels, and to assess if HMB levels correlated to total appendicular lean mass and forearm grip strength. Anthropometry, dietary and physical activity assessment, and the estimation of fasting plasma HMB concentrations and handgrip strength were performed on the 305 subjects (children, young adults and older adults). Lean mass, which serves as a surrogate for muscle mass was measured using dual energy X-ray absorptiometry (DEXA). Mean plasma HMB concentrations were significantly lower with increasing age groups, with children having highest mean HMB concentration (p<0.01) followed by young adults and older adults. Female subjects (across all ages) had significantly lower plasma HMB concentrations. A significant positive correlation between HMB concentrations and appendicular lean mass normalized for body weight (%), appendicular lean mass (r=0.37; p<0.001) was observed in the young adults and older adults group. Handgrip strength was positively associated with plasma HMB concentrations in young adults (r=0.58; p<0.01) and the older adults group (r=0.28; p<0.01). The findings of the present study suggest that there is an age- related decline in endogenous HMB concentrations in humans and the HMB concentrations were positively correlated with appendicular lean mass and hand grip strength in young adults and older adults group. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. 21 CFR 26.4 - Product coverage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... subpart. (b) Human blood, human plasma, human tissues and organs, and veterinary immunologicals (under 9... the scope of this subpart. Human plasma derivatives (such as immunoglobulins and albumin...

  16. 21 CFR 26.4 - Product coverage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... subpart. (b) Human blood, human plasma, human tissues and organs, and veterinary immunologicals (under 9... the scope of this subpart. Human plasma derivatives (such as immunoglobulins and albumin...

  17. Chocolate procyanidins decrease the leukotriene-prostacyclin ratio in humans and human aortic endothelial cells.

    PubMed

    Schramm, D D; Wang, J F; Holt, R R; Ensunsa, J L; Gonsalves, J L; Lazarus, S A; Schmitz, H H; German, J B; Keen, C L

    2001-01-01

    Polyphenolic phytochemicals inhibit vascular and inflammatory processes that contribute to disease. These effects are hypothesized to result from polyphenol-mediated alterations in cellular eicosanoid synthesis. The objective was to determine and compare the ability of cocoa procyanidins to alter eicosanoid synthesis in human subjects and cultured human aortic endothelial cells. After an overnight fast, 10 healthy subjects (4 men and 6 women) consumed 37 g low-procyanidin (0.09 mg/g) and high-procyanidin (4.0 mg/g) chocolate; the treatments were separated by 1 wk. The investigation had a randomized, blinded, crossover design. Plasma samples were collected before treatment and 2 and 6 h after treatment. Eicosanoids were quantitated by enzyme immunoassay. Endothelial cells were treated in vitro with procyanidins to determine whether the effects of procyanidin in vivo were associated with procyanidin-induced alterations in endothelial cell eicosanoid synthesis. Relative to the effects of the low-procyanidin chocolate, high-procyanidin chocolate induced increases in plasma prostacyclin (32%; P<0.05) and decreases in plasma leukotrienes (29%; P<0.04). After the in vitro procyanidin treatments, aortic endothelial cells synthesized twice as much 6-keto-prostaglandin F(1alpha) (P<0.01) and 16% less leukotriene (P<0.05) as did control cells. The in vitro and in vivo effects of procyanidins on plasma leukotriene-prostacyclin ratios in culture medium were also comparable: decreases of 58% and 52%, respectively. Data from this short-term investigation support the concept that certain food-derived flavonoids can favorably alter eicosanoid synthesis in humans, providing a plausible hypothesis for a mechanism by which they can decrease platelet activation in humans.

  18. The importance of selecting a proper biological milieu for protein corona analysis in vitro: Human plasma versus human serum.

    PubMed

    Mirshafiee, Vahid; Kim, Raehyun; Mahmoudi, Morteza; Kraft, Mary L

    2016-06-01

    Nanoparticle (NP) exposure to biological fluids in the body results in protein binding to the NP surface, which forms a protein coating that is called the "protein corona". To simplify studies of protein-NP interactions and protein corona formation, NPs are incubated with biological solutions, such as human serum or human plasma, and the effects of this exposure are characterized in vitro. Yet, how NP exposure to these two different biological milieus affects protein corona composition and cell response has not been investigated. Here, we explore the differences between the protein coronas that form when NPs are incubated in human serum versus human plasma. NP characterization indicated that NPs that were exposed to human plasma had higher amounts of proteins bound to their surfaces, and were slightly larger in size than those exposed to human serum. In addition, significant differences in corona composition were also detected with gel electrophoresis and liquid chromatography-mass spectrometry/mass spectrometry, where a higher fraction of coagulation proteins and complement factors were found on the plasma-exposed NPs. Flow cytometry and confocal microscopy showed that the uptake of plasma-exposed NPs was higher than that of serum-exposed NPs by RAW 264.7 macrophage immune cells, but not by NIH 3T3 fibroblast cells. This difference is likely due to the elevated amounts of opsonins, such as fibrinogen, on the surfaces of the NPs exposed to plasma, but not serum, because these components trigger NP internalization by immune cells. As the human plasma better mimics the composition of the in vivo environment, namely blood, in vitro protein corona studies should employ human plasma, and not human serum, so the biological phenomena that is observed is more similar to that occurring in vivo. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Epstein-Barr Virus (EBV) DNA in plasma is not encapsidated in patients with EBV-related malignancies.

    PubMed

    Ryan, Julie L; Fan, Hongxin; Swinnen, Lode J; Schichman, Steven A; Raab-Traub, Nancy; Covington, Mary; Elmore, Sandra; Gulley, Margaret L

    2004-06-01

    Epstein-Barr Virus (EBV), a ubiquitous gamma herpes virus, infects more than 95% of the human population before adulthood. Life-long persistence, usually without adverse health consequences, relies on a balance between viral latency, viral replication, and host immune response. Patients with EBV-related disease often have high levels of EBV DNA in their plasma. This study addresses whether this circulating, cell-free EBV DNA is encapsidated in virions or exists as naked genomes. First, an assay was developed, combining DNase I and quantitative real-time PCR, to discriminate encapsidated from naked EBV DNA. EBV DNA was almost always naked in the plasma of AIDS-related lymphoma patients (n = 11) and immunosuppressed/posttransplantation patients (n = 8). In contrast, infectious mononucleosis patients (n = 30) often had a mixture of encapsidated and naked EBV DNA. These findings may be important in understanding how viral load relates to disease status and in predicting response to nucleoside analogs and other antiviral therapies.

  20. Effect of anticoagulants on the protein corona-induced reduced drug carrier adhesion efficiency in human blood flow.

    PubMed

    Sobczynski, Daniel J; Eniola-Adefeso, Omolola

    2017-01-15

    Plasma proteins rapidly coat the surfaces of particulate drug carriers to form a protein corona upon their injection into the bloodstream. The high presence of immunoglobulins in the corona formed on poly(lactic-co-glycolic acid) (PLGA) vascular-targeted carrier (VTC) surfaces was recently shown to negatively impact their adhesion to activated endothelial cells (aECs) in vitro. Here, we characterized the influence of anticoagulants, or their absence, on the binding efficiency of VTCs of various materials via modulation of their protein corona. Specifically, we evaluated the adhesion of PLGA, poly(lactic acid) (PLA), polycaprolactone (PCL), silica, and polystyrene VTCs to aECs in heparinized, citrated, and non-anticoagulated (serum and whole) blood flows relative to buffer control. Particle adhesion is substantially reduced in non-anticoagulated blood flows regardless of the material type while only moderate to minimal reduction is observed for VTCs in anticoagulant-containing blood flow depending on the anticoagulant and material type. The substantial reduction in VTC adhesion in blood flows was linked to a high presence of immunoglobulin-sized proteins in the VTC corona via SDS-PAGE analysis. Of all the materials evaluated, PLGA was the most sensitive to plasma protein effects while PCL was the most resistant, suggesting particle hydrophobicity is a critical component of the observed negative plasma protein effects. Overall, this work demonstrates that anticoagulant positively alters the effect of plasma proteins in prescribing VTC adhesion to aECs in human blood flow, which has implication in the use of in vitro blood flow assays for functional evaluation of VTCs for in vivo use. This study addresses the impact of anticoagulant on altering the extent of the previously observed protein corona-induced adhesion reduction of vascular-targeted drug carriers in human blood flows. Specifically, serum blood flow (no anticoagulant) magnifies the negative effect of the plasma protein corona on drug carrier adhesion relative to citrated or heparinized blood flows. Overall, the results from this work suggest that serum better predicts targeted drug carrier adhesion efficiency in vivo compared to anticoagulant containing plasma. Furthermore, this study offers critical insight into the importance of how the choice of anticoagulant can greatly affect drug delivery-related processes in vitro. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  1. A multi-matrix HILIC-MS/MS method for the quantitation of endogenous small molecule neurological biomarker N-acetyl aspartic acid (NAA).

    PubMed

    Sangaraju, Dewakar; Shahidi-Latham, Sheerin K; Burgess, Braydon L; Dean, Brian; Ding, Xiao

    2017-06-05

    A multi-matrix hydrophilic interaction liquid chromatography tandem mass spectrometric method (HILIC-MS/MS) was developed for the quantitation of N-Acetyl Aspartic acid (NAA) using stable isotope labeled internal standard, D3-NAA in various biological matrices such as human plasma, human CSF, mouse plasma, brain and spinal cord. A high throughput 96-well plate format supported liquid extraction (SLE) procedure was developed and used for sample preparation. Mass spectrometric analysis of NAA was performed using selected reaction monitoring transitions in positive electrospray ionization mode. As NAA is endogenously present, a surrogate matrix approach was used for quantitation of NAA and the method was qualified over linear calibration curve range of 0.01-10μg/mL. Intra and inter assay precision indicated by percent relative standard deviation (%RSD) was less than 7.1% for low, medium, medium high and high QCs. The accuracy of the method ranged from 92.6-107.0% of nominal concentration for within-run and between-run for the same QCs. Extraction recovery of NAA and D3-NAA was greater than 76%. Stability of NAA was established in the above biological matrices under bench top (RT, 5h), freeze thaw (-20±10°C, 3 cycles) and moues/human plasma sample collection (Wet ice, RT) conditions. HILIC-MS/MS method was then used to quantify and compare the NAA levels in human plasma and CSF of ALS patients versus control human subjects. NAA CSF levels in control human subjects (73.3±31.0ng/mL,N=10) were found to be slightly higher than ALS patients (46.1±22.6ng/mL, N=10) (P=0.04). No differences were observed in NAA plasma levels in human control subjects (49.7±13.8ng/mL,N=9) as compared to ALS patients (49.6±8.1ng/mL, N=10) (P=0.983). NAA endogenous concentrations in mouse plasma, brain and spinal cord were found to be 243.8±56.8ng/mL (N=6), 1029.8±115.2μg/g tissue weight (N=5) and 487.6±178.4μg/g tissue weight (N=5) respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. 21 CFR 640.60 - Source Plasma.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Source Plasma. 640.60 Section 640.60 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood collected by...

  3. Comparative Inter-Species Pharmacokinetics of Phenoxyacetic Acid Herbicides and Related Organic Acids. Evidence that the Dog is Not a Relevant Species for Evaluation of Human Health Risk.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timchalk, Chuck

    Phenoxyacetic acids including 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) are widely utilized organic acid herbicides that have undergone extensive toxicity and pharmacokinetic analyses. The dog is particularly susceptible to the toxicity of phenoxyacetic acids and related organic acids relative to other species. Active renal clearance mechanisms for organic acids are ubiquitous in mammalian species, and thus a likely mechanism responsible for the increased sensitivity of the dog to these agents is linked to a lower capacity to secrete organic acids from the kidney. Using published data describing the pharmacokinetics of phenoxyacetic and structurally related organic acids in a varietymore » of species including humans, inter-species comparative pharmacokinetics were evaluated using allometic parameter scaling. For both 2,4-D and MCPA the dog plasma half-life (t1/2) and renal clearance (Clr; ml hr-1) rates did not scale as a function of body weight across species; whereas for all other species evaluated, including humans, these pharmacokinetic parameters reasonably scaled. This exceptional response in the dog is clearly illustrated by comparing the plasma t1/2 at comparable doses of 2,4-D and MCPA, across several species. At a dosage of 5 mg/kg, in dogs the plasma t1/2 for 2,4-D and MCPA were {approx}92 - 106 hr and 63 hr, respectively, which is substantially longer than in the rat ({approx}1 and 6 hr, respectively) or in humans (12 and 11 hr, respectively). This longer t1/2, and slower elimination in the dog, results in substantially higher body burdens of these organic acids, at comparable doses, relative to other species. Although these results indicate the important role of renal transport clearance mechanisms as determinants of the clearance and potential toxicity outcomes of phenoxyacetic acid herbicides across several species, other contributing mechanisms such as reabsorption from the renal tubules is highly likely. These findings suggest that for new structurally similar organic acids, a limited comparative species (rat vs. dog) pharmacokinetic analysis early in the toxicology evaluation process may provide important insight into the relevance of the dog. In summary, the substantial difference between the pharmacokinetics of phenoxyacetic acids and related organic acids in dogs relative to other species, including humans, questions the relevance of using dog toxicity data for the extrapolation of human health risk.« less

  4. Label-free quantitative proteomic analysis of human plasma-derived microvesicles to find protein signatures of abdominal aortic aneurysms.

    PubMed

    Martinez-Pinna, Roxana; Gonzalez de Peredo, Anne; Monsarrat, Bernard; Burlet-Schiltz, Odile; Martin-Ventura, Jose Luis

    2014-08-01

    To find potential biomarkers of abdominal aortic aneurysms (AAA), we performed a differential proteomic study based on human plasma-derived microvesicles. Exosomes and microparticles isolated from plasma of AAA patients and control subjects (n = 10 each group) were analyzed by a label-free quantitative MS-based strategy. Homemade and publicly available software packages have been used for MS data analysis. The application of two kinds of bioinformatic tools allowed us to find differential protein profiles from AAA patients. Some of these proteins found by the two analysis methods belong to main pathological mechanisms of AAA such as oxidative stress, immune-inflammation, and thrombosis. Data analysis from label-free MS-based experiments requires the use of sophisticated bioinformatic approaches to perform quantitative studies from complex protein mixtures. The application of two of these bioinformatic tools provided us a preliminary list of differential proteins found in plasma-derived microvesicles not previously associated to AAA, which could help us to understand the pathological mechanisms related to this disease. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Development and Clinical Application of a New Method for the Radioimmunoassay of Arginine Vasopressin in Human Plasma

    PubMed Central

    Robertson, Gary L.; Mahr, Ermelinda A.; Athar, Shahid; Sinha, Tushar

    1973-01-01

    A radioimmunoassay has been developed that permits reliable measurements of plasma arginine vasopressin (AVP) at concentrations as low as 0.5 pg/ml in sample volumes of 1 ml or less. Nonhormonal immunoreactivity associated with the plasma proteins is eliminated by acetone precipitation before assay, leaving unaltered a component that is immunologically and chromatographically indistinguishable from standard AVP. Storage of plasma results in a decline in AVP concentration and, thus, must be carefully regulated. The plasma AVP values obtained by our method approximate the anticipated levels and vary in accordance with physiologic expections. In recumbent normal subjects, plasma AVP ranged from (mean ±SD) 5.4±3.4 pg/ml after fluid deprivation to 1.4±0.8 pg/ml after water loading, and correlated significantly with both plasma osmolality (r=0.52; P<0.001) and urine osmolality (r=0.77; P<0.001). After fluid restriction, plasma AVP was uniformly normal relative to plasma osmolality in patients with nephrogenic diabetes insipidus and primary polydipsia but was distinctly subnormal in all patients with pituitary diabetes insipidus. The infusion of physiologic amounts of posterior pituitary extract caused a dose-related rise in plasma vasopressin that afterwards declined at the expected rate (t½=22.5±4 min). We conclude that, when used appropriately, our radioimmunoassay method provides a useful way of assessing AVP function in man. PMID:4727463

  6. Determination of human insulin in dog plasma by a selective liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetic study.

    PubMed

    Dong, Shiqi; Zeng, Yong; Wei, Guangli; Si, Duanyun; Liu, Changxiao

    2018-03-01

    A simple, sensitive and selective LC-MS/MS method for quantitative analysis of human insulin was developed and validated in dog plasma. Insulin glargine was used as the internal standard. After a simple step of solid-phase extraction, the chromatographic separation of human insulin was achieved by using InertSustain Bio C18 column with a mobile phase of acetonitrile containing 1% formic acid (A)-water containing 1% formic acid (B). The detection was performed by positive ion electrospray ionization in multiple-reaction monitoring (MRM) mode. Good linearity was observed in the concentration range of 1-1000 μIU/mL (r 2  > 0.99), and the lower limit of quantification was 1 μIU/mL (equal to 38.46 pg/mL). The intra- and inter-day precision (expressed as relative standard deviation, RSD) of human insulin were ≤12.1% and ≤13.0%, respectively, and the accuracy (expressed as relative error, RE) was in the range of -7.23-11.9%. The recovery and matrix effect were both within acceptable limits. This method was successfully applied for the pharmacokinetic study of human insulin in dogs after subcutaneous administration. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of blonanserin and its metabolite in human plasma and urine by liquid chromatography-tandem mass spectrometry: application to a pharmacokinetic study.

    PubMed

    Wen, Yu-Guan; Ni, Xiao-Jia; Zhang, Ming; Liu, Xia; Shang, De-Wei

    2012-08-15

    Blonanserin is a novel atypical antipsychotic with highly selective receptor antagonist activity to dopamine D₂ and 5-HT(2A). N-desethyl blonanserin (blonanserin C) is its major active metabolite in human plasma. Herein we report a new highly sensitive, selective, and rapid liquid chromatography-tandem mass spectrometry method to determine blonanserin and blonanserin C simultaneously in human plasma and urine, with N-desethyl-chlor-blonanserin (blonanserin D) as internal standard (IS). Blonanserin and blonanserin C were extracted from aliquots of plasma and urine with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using an Agilent Eclipse Plus C₁₈ column. The mobile phase was composed of: acetonitrile and ammonium formate-formic acid buffer containing 5mM ammonium formate and 0.1% formic acid (87:13, v/v). To quantify blonanserin, blonanserin C, and blonanserin D, respectively, multiple reaction monitoring (MRM) transition of m/z 368.2→297.2, m/z 340.2→297.1, and m/z 356.2→313.3 was performed in positive mode. The analysis time was about 5.5 min. The calibration curve was linear in the concentration range of 0.01-2 ng/ml. The lower limit of quantification reached 0.01 ng/ml. The intra and inter-day precision and relative errors were less than 8.0% and 6.6% for three QC levels in plasma and urine. The current LC-MS/MS method was validated as simple, sensitive, and accurate and has been successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in humans. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Comparison of the docetaxel concentration in human plasma measured with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and a nanoparticle immunoassay and clinical applications of that assay.

    PubMed

    Geng, Chunmei; Li, Pingli; Chen, Xuwang; Yuan, Guiyan; Guo, Nan; Liu, Huanjun; Zhang, Rui; Guo, Ruichen

    2017-05-23

    To determine the feasibility of using a nanoparticle immunoassay for clinical therapeutic drug monitoring (TDM) of docetaxel concentrations, a sensitive and simple method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established to measure the docetaxel concentration in human plasma and the results of LC-MS/MS and the immunoassay were compared. Docetaxel and paclitaxel (the internal standard, or IS) in human plasma were extracted through protein precipitation, separated on a Diamonsil C18 column (150 mm × 4.6 mm, 5 μm), ionized with positive ions, and detected with LC-MS/MS in multi-reaction monitoring (MRM) mode. Plasma samples from 248 cancer patients were assayed with LC-MS/MS and a nanoparticle immunoassay. Data from the samples were analyzed with the statistical software SPSS and the software MedCalc. Results indicated that the calibration curve of the validated method of LC-MS/MS was linear over the range of 10-2,000 ng/mL, with an lowest limit of quantitation (LLOQ) of 10 ng/mL, and the intra- and inter- day precision and accuracy were both < ± 15%. Comparison of the two methods indicated that results of the LC-MS/MS were closely related to those of the nanoparticle immunoassay, with a correlation coefficient (R) of 0.965 and acceptable 95% confidence intervals (CI) of ‒ 231.7-331.1 ng/mL. Overall, the established method of LC-MC/MS and the nanoparticle immunoassay were both suitable for measurement of the docetaxel concentration in human plasma, and the immunoassay was far more cost-effective and better at clinical TDM of docetaxel in clinical practice.

  9. Physiologically based pharmacokinetic modeling of tea catechin mixture in rats and humans.

    PubMed

    Law, Francis C P; Yao, Meicun; Bi, Hui-Chang; Lam, Stephen

    2017-06-01

    Although green tea ( Camellia sinensis) (GT) contains a large number of polyphenolic compounds with anti-oxidative and anti-proliferative activities, little is known of the pharmacokinetics and tissue dose of tea catechins (TCs) as a chemical mixture in humans. The objectives of this study were to develop and validate a physiologically based pharmacokinetic (PBPK) model of tea catechin mixture (TCM) in rats and humans, and to predict an integrated or total concentration of TCM in the plasma of humans after consuming GT or Polyphenon E (PE). To this end, a PBPK model of epigallocatechin gallate (EGCg) consisting of 13 first-order, blood flow-limited tissue compartments was first developed in rats. The rat model was scaled up to humans by replacing its physiological parameters, pharmacokinetic parameters and tissue/blood partition coefficients (PCs) with human-specific values. Both rat and human EGCg models were then extrapolated to other TCs by substituting its physicochemical parameters, pharmacokinetic parameters, and PCs with catechin-specific values. Finally, a PBPK model of TCM was constructed by linking three rat (or human) tea catechin models together without including a description for pharmacokinetic interaction between the TCs. The mixture PBPK model accurately predicted the pharmacokinetic behaviors of three individual TCs in the plasma of rats and humans after GT or PE consumption. Model-predicted total TCM concentration in the plasma was linearly related to the dose consumed by humans. The mixture PBPK model is able to translate an external dose of TCM into internal target tissue doses for future safety assessment and dose-response analysis studies in humans. The modeling framework as described in this paper is also applicable to the bioactive chemical in other plant-based health products.

  10. Acute regulation of plasma leptin by isoprenaline in lean and obese fasted subjects.

    PubMed

    Baynes, K C R; Nicholas, M D; Shojaee-Moradie, F; Umpleby, A M; Giannoulis, M G

    2006-07-01

    In human obesity, there is some evidence for impaired adrenergic sensitivity with respect to catecholamine-induced lipolysis. The beta-adrenoceptor agonist isoprenaline has been shown to suppress plasma leptin levels in lean humans in vivo. We hypothesized that a reduced adrenergic sensitivity in obese humans would result in impaired suppression of leptin secretion. Eight obese [Ob, body mass index (BMI) = 33.3 kg/m2] and seven lean (Ln, BMI = 21.8 kg/m2) men were studied after an overnight fast. Intravenous isoprenaline infusion was initiated at a rate of 8 ng/kg/min, titrated up to 24 ng/kg/min over 30 min and continued at this rate for a further 120 min with continuous electrocardiogram monitoring. Baseline fasting plasma leptin was higher in obese compared with lean subjects (Ob 12.2 +/- 1.8, Ln 2.6 +/- 0.6 ng/ml, p < 0.05 unpaired t-test). Baseline fasting glycerol as a measure of lipolysis was similar in both groups (Ob 62.9 +/- 7.6, Ln 42.4 +/- 8.9 micromol/l) and increased from baseline to 150 min by equivalent amounts (Ob +66.9%, Ln +81.2%, p = NS). Plasma leptin decreased from baseline to 150 min with similar relative changes in both groups (Ob -29.2%, Ln -27.8%). Obese subjects show a similar lipolytic and leptin response to acute isoprenaline infusion compared with lean subjects. Impaired beta-adrenergic-induced inhibition of leptin secretion does not appear to contribute to hyperleptinaemia in obese human subjects.

  11. A new restricted access molecularly imprinted polymer capped with albumin for direct extraction of drugs from biological matrices: the case of chlorpromazine in human plasma.

    PubMed

    de Oliveira Isac Moraes, Gabriel; da Silva, Larissa Meirelles Rodrigues; dos Santos-Neto, Alvaro José; Florenzano, Fábio Herbst; Figueiredo, Eduardo Costa

    2013-09-01

    A new restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was developed, characterized, and used for direct analysis of chlorpromazine in human plasma samples. The RAMIP-BSA was synthesized using chlorpromazine, methacrylic acid, and ethylene glycol dimethacrylate as template, functional monomer, and cross-linker, respectively. Glycerol dimethacrylate and hydroxy methyl methacrylate were used to promote a hydrophilic surface (high density of hydroxyl groups). Afterward, the polymer was coated with BSA using glutaraldehyde as cross-linker, resulting in a protein chemical shield around it. The material was able to eliminate ca. 99% of protein when a 44-mg mL(-1) BSA aqueous solution was passed through it. The RAMIP-BSA was packed in a column and used for direct analysis of chlorpromazine in human plasma samples in an online column switching high-performance liquid chromatography system. The analytical calibration curve was prepared in a pool of human plasma samples with chlorpromazine concentrations ranging from 30 to 350 μg L(-1). The correlation coefficient obtained was 0.995 and the limit of quantification was 30 μg L(-1). Intra-day and inter-day precision and accuracy presented variation coefficients and relative errors lower than 15% and within -15 and 15%, respectively. The sample throughput was 3 h(-1) (sample preparation and chromatographic analysis steps) and the same RAMIP-BSA column was efficiently used for about 90 cycles.

  12. A rapid method for selecting suitable animal species for studying pathogen interactions with plasma protein ligands in vivo.

    PubMed

    Naudin, Clément; Schumski, Ariane; Salo-Ahen, Outi M H; Herwald, Heiko; Smeds, Emanuel

    2017-05-01

    Species tropism constitutes a serious problem for developing relevant animal models of infection. Human pathogens can express virulence factors that show specific selectivity to human proteins, while their affinity for orthologs from other species can vary significantly. Suitable animal species must be used to analyse whether virulence factors are potential targets for drug development. We developed an assay that rapidly predicts applicable animal species for studying virulence factors binding plasma proteins. We used two well-characterized Staphylococcus aureus proteins, SSL7 and Efb, to develop an ELISA-based inhibition assay using plasma from different animal species. The interaction between SSL7 and human C5 and the binding of Efb to human fibrinogen and human C3 was studied. Affinity experiments and Western blot analyses were used to validate the assay. Human, monkey and cat plasma interfered with binding of SSL7 to human C5. Binding of Efb to human fibrinogen was blocked in human, monkey, gerbil and pig plasma, while human, monkey, gerbil, rabbit, cat and guinea pig plasma inhibited the binding of Efb to human C3. These results emphasize the importance of choosing correct animal models, and thus, our approach is a rapid and cost-effective method that can be used to prevent unnecessary animal experiments. © 2017 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  13. Is Lutein a Physiologically Important Ligand for Transthyretin in Humans?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Liwei

    Lutein and zeaxanthin are the only carotenoids accumulated in the macula of the human retina and are known as the macular pigments (MP). These pigments account for the yellow color of the macula and appear to play an important role in protecting against age-related macular degeneration (AMD). The uptake of lutein and zeaxanthin in human eyes is remarkably specific. It is likely that specific transport or binding proteins are involved. The objective is to determine whether transthyretin (TTR) is a transport protein in human plasma and could thus deliver lutein from the blood to the retina. In this study, theymore » used a biosynthetic 13C-lutein tracer and gas chromatography-combustion interfaced-isotope ratio mass spectrometry (GCC-IRMS) to gain the requisite sensitivity to detect the minute amounts of lutein expected as a physiological ligand for human transthyretin. The biosynthetic 13C-labeled lutein tracer was purified from algae. Healthy women (n = 4) each ingested 1 mg of 13C-labeled lutein daily for 3 days and a blood sample was collected 24 hours after the final dose. Plasma TTR was isolated by retinol-binding protein (RBP)-sepharose affinity chromatography and extracted with chloroform. The 13C/ 12C ratio in the TTR extract was measured by GCC-IRMS. There was no 13C-lutein enrichment in the pure TTR extract. This result indicated that lutein is not associated with TTR in human plasma after ingestion in physiological amounts. Some hydrophobic compounds with yellow color may bind to human TTR in the plasma. However, this association needs to be further proved by showing specificity. The study provides a new approach for carotenoid-binding protein studies using a stable isotope tracer method combined with the high precision of GCC-IRMS. The mechanism of selective transport, uptake, and accumulation of lutein in human macula remain to be determined.« less

  14. Cross-species and tissue variations in cyanide detoxification rates in rodents and non-human primates on protein-restricted diet.

    PubMed

    Kimani, S; Moterroso, V; Morales, P; Wagner, J; Kipruto, S; Bukachi, F; Maitai, C; Tshala-Katumbay, D

    2014-04-01

    We sought to elucidate the impact of diet, cyanide or cyanate exposure on mammalian cyanide detoxification capabilities (CDC). Male rats (~8 weeks old) (N=52) on 75% sulfur amino acid (SAA)-deficient diet were treated with NaCN (2.5mg/kg bw) or NaOCN (50mg/kg bw) for 6 weeks. Macaca fascicularis monkeys (~12 years old) (N=12) were exclusively fed cassava for 5 weeks. CDC was assessed in plasma, or spinal cord, or brain. In rats, NaCN induced seizures under SAA-restricted diet whereas NaOCN induced motor deficits. No deficits were observed in non-human primates. Under normal diet, the CDC were up to ~80× faster in the nervous system (14 ms to produce one μmol of thiocyanate from the detoxification of cyanide) relative to plasma. Spinal cord CDC was impaired by NaCN, NaOCN, or SAA deficiency. In M. fascicularis, plasma CDC changed proportionally to total proteins (r=0.43; p<0.001). The plasma CDC was ~2× relative to that of rodents. The nervous system susceptibility to cyanide may result from a "multiple hit" by the toxicity of cyanide or its cyanate metabolite, the influences of dietary deficiencies, and the tissue variations in CDC. Chronic dietary reliance on cassava may cause metabolic derangement including poor CDC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Cross-species and tissue variations in cyanide detoxification rates in rodents and non-human primates on protein-restricted diet

    PubMed Central

    Kimani, S.; Moterroso, V.; Morales, P.; Wagner, J.; Kipruto, S.; Bukachi, F.; Maitai, C.; Tshala-Katumbay, D.

    2014-01-01

    We sought to elucidate the impact of diet, cyanide or cyanate exposure on mammalian cyanide detoxification capabilities (CDC). Male rats (~8 weeks old) (N=52) on 75% sulfur amino acid (SAA)-deficient diet were treated with NaCN (2.5 mg/kg bw) or NaOCN (50 mg/kg bw) for 6 weeks. Macaca fascicularis monkeys (~12 years old) (N=12) were exclusively fed cassava for 5 weeks. CDC was assessed in plasma, or spinal cord, or brain. In rats, NaCN induced seizures under SAA-restricted diet whereas NaOCN induced motor deficits. No deficits were observed in non-human primates. Under normal diet, the CDC were up to ~ 80X faster in the nervous system (14 milliseconds to produce one μmol of thiocyanate from the detoxification of cyanide) relative to plasma. Spinal cord CDC was impaired by NaCN, NaOCN, or SAA deficiency. In macaca fascicularis, plasma CDC changed proportionally to total proteins (r=0.43; p<0.001). The plasma CDC was ~ 2X relative to that of rodents. The nervous system susceptibility to cyanide may result from a “multiple hit” by the toxicity of cyanide or its cyanate metabolite, the influences of dietary deficiencies, and the tissue variations in CDC. Chronic dietary reliance on cassava may cause metabolic derangement including poor CDC. PMID:24500607

  16. The Oral Bioavailability of Trans-Resveratrol from a Grapevine-Shoot Extract in Healthy Humans is Significantly Increased by Micellar Solubilization.

    PubMed

    Calvo-Castro, Laura A; Schiborr, Christina; David, Franziska; Ehrt, Heidi; Voggel, Jenny; Sus, Nadine; Behnam, Dariush; Bosy-Westphal, Anja; Frank, Jan

    2018-05-01

    Grapevine-shoot extract Vineatrol30 contains abundant resveratrol monomers and oligomers with health-promoting potential. However, the oral bioavailability of these compounds in humans is low (˂1-2%). The aim of this study was to improve the oral bioavailability of resveratrol from vineatrol by micellar solubilization. Twelve healthy volunteers (six women, six men) randomly ingested a single dose of 500 mg vineatrol (30 mg trans-resveratrol, 75 mg trans-ε-viniferin) as native powder or liquid micelles. Plasma and urine were collected at baseline and over 24 h after intake. Resveratrol and viniferin were analyzed by HPLC. The area under the plasma concentration-time curve (AUC) and mean maximum plasma trans-resveratrol concentrations were 5.0-fold and 10.6-fold higher, respectively, after micellar supplementation relative to the native powder. However, no detectable amounts of trans-ε-viniferin were found in either plasma or urine. The transepithelial permeability of trans-resveratrol and trans-ε-viniferin across differentiated Caco-2 monolayers was consistent to the absorbed fractions in vivo. The oral bioavailability of trans-resveratrol from the grapevine-shoot extract Vineatrol30 was significantly increased using a liquid micellar formulation, without any treatment-related adverse effects, making it a suitable system for improved supplementation of trans-resveratrol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Comparative lytic efficacy of rt-PA and ultrasound in porcine versus human clots

    PubMed Central

    Shekhar, Himanshu; Holland, Christy K.

    2017-01-01

    Introduction Porcine thrombi are employed routinely in preclinical models of ischemic stroke. In this study, we examined the differential lytic susceptibility of porcine and human whole blood clots with and without the use of microbubbles and ultrasound (US) as an adjuvant. Materials and methods An in vitro system equipped with time-lapse microscopy was used to evaluate recombinant tissue-plasminogen activator (rt-PA) lysis of porcine and human clots in the same species or cross species plasma. Human and porcine whole blood clots were treated with rt-PA and an echo contrast agent, Definity®, and exposed to intermittent 120 kHz US. Results and conclusions The rt-PA lytic efficacy observed for porcine clots in porcine plasma was 22 times lower than for human clots in human plasma reported previously. Further, porcine clots did not exhibit increased lysis with adjuvant Definity® and US exposure. However, the rt-PA lytic susceptibility of the porcine clots in human plasma was similar to that of human clots in human plasma. Human clots perfused with porcine plasma did not respond to rt-PA, but adjuvant use of Definity® and US enhanced lysis. These results reveal considerable differences in lytic susceptibility of porcine clots and human clots to rt-PA. The use of porcine clot models to test new human thrombolytic therapies may necessitate modulation of coagulation and thrombolytic factors to reflect human hemostasis accurately. PMID:28545055

  18. Red Blood Cell Susceptibility to Pneumolysin

    PubMed Central

    Bokori-Brown, Monika; Petrov, Peter G.; Khafaji, Mawya A.; Mughal, Muhammad K.; Naylor, Claire E.; Shore, Angela C.; Gooding, Kim M.; Casanova, Francesco; Mitchell, Tim J.; Titball, Richard W.; Winlove, C. Peter

    2016-01-01

    This study investigated the effect of the biochemical and biophysical properties of the plasma membrane as well as membrane morphology on the susceptibility of human red blood cells to the cholesterol-dependent cytolysin pneumolysin, a key virulence factor of Streptococcus pneumoniae, using single cell studies. We show a correlation between the physical properties of the membrane (bending rigidity and surface and dipole electrostatic potentials) and the susceptibility of red blood cells to pneumolysin-induced hemolysis. We demonstrate that biochemical modifications of the membrane induced by oxidative stress, lipid scrambling, and artificial cell aging modulate the cell response to the toxin. We provide evidence that the diversity of response to pneumolysin in diabetic red blood cells correlates with levels of glycated hemoglobin and that the mechanical properties of the red blood cell plasma membrane are altered in diabetes. Finally, we show that diabetic red blood cells are more resistant to pneumolysin and the related toxin perfringolysin O relative to healthy red blood cells. Taken together, these studies indicate that the diversity of cell response to pneumolysin within a population of human red blood cells is influenced by the biophysical and biochemical status of the plasma membrane and the chemical and/or oxidative stress pre-history of the cell. PMID:26984406

  19. ToF-SIMS study of differentiation of human bone-derived stromal cells: new insights into osteoporosis.

    PubMed

    Schaepe, Kaija; Werner, Janina; Glenske, Kristina; Bartges, Tessa; Henss, Anja; Rohnke, Marcus; Wenisch, Sabine; Janek, Jürgen

    2017-07-01

    Lipids have numerous important functions in the human body, as they form the cells' plasma membranes and play a key role in many disease states, presumably also in osteoporosis. Here, the fatty acid composition of the outer plasma membranes of cells differentiated into the osteogenic and adipogenic direction is studied with surface-sensitive time-of-flight secondary ion mass spectrometry (ToF-SIMS). For data evaluation, principal component analysis (PCA) is applied. Human (bone-derived) mesenchymal stromal cells (hMSCs) from an osteoporotic donor and a control donor are compared to reveal differences in the fatty acid composition of the membranes. The chemical information is correlated to staining and real-time quantitative polymerase chain reaction (rt-qPCR) results to provide insight into the gene expression of several differentiation markers on the RNA level. Adipogenic differentiation of hMSCs from a non-osteoporotic donor correlates with increased relative intensities of all fatty acids under investigation. After osteogenic differentiation of non-osteoporotic cells, the relative mass signal intensities of unsaturated fatty acids such as oleic and linoleic acids are increased. However, the osteoporotic cells show increased levels of palmitic acid in the plasma membrane after exposure to osteogenic differentiation conditions, which correlates to an immature differentiation state relative to non-osteoporotic osteogenic cells. This immature differentiation state is confirmed by increased early osteogenic differentiation factor Runx2 on RNA level and by less calcium mineralization spots seen in von Kossa staining and ToF-SIMS images. Graphical abstract Time-of-flight secondary ion mass spectrometry is applied to analyze the fatty acid composition of the outer plasma membranes of cells differentiated into the adipogenic and osteogenic direction. Cells from an osteoporotic and a control donor are compared to reveal differences due to differentiation and disease stage of the cells.

  20. Plasma fatty acid levels and gene expression related to lipid metabolism in peripheral blood mononuclear cells: a cross-sectional study in healthy subjects.

    PubMed

    Larsen, Sunniva V; Holven, Kirsten B; Ottestad, Inger; Dagsland, Kine N; Myhrstad, Mari C W; Ulven, Stine M

    2018-01-01

    Solid evidence indicates that intake of marine n-3 fatty acids lowers serum triglycerides and that replacing saturated fatty acids (SFA) with polyunsaturated fatty acids (PUFA) reduces plasma total cholesterol and LDL cholesterol. The molecular mechanisms underlying these health beneficial effects are however not completely elucidated. The aim of this study was therefore to investigate the expression of genes related to lipid metabolism in peripheral blood mononuclear cells (PBMC) depending on the plasma levels of n-6 and n-3 fatty acids and the SFA to PUFA ratio. Fifty-four healthy subjects were grouped into tertiles ( n  = 18) based on plasma levels of n-6 and n-3 fatty acids and the SFA to PUFA ratio. The PBMC gene expression levels among subjects in the highest versus the lowest tertiles were compared. In total, 285 genes related to cholesterol and triglyceride metabolism were selected for this explorative study. Among the 285 selected genes, 161 were defined as expressed in the PBMCs. The plasma SFA to PUFA ratio was associated with the highest number of significantly different expressed genes (25 gene transcripts), followed by plasma n-6 fatty acid level (15 gene transcripts) and plasma n-3 fatty acid level (8 gene transcripts). In particular, genes involved in cholesterol homeostasis were significantly different expressed among subjects with high compared to low plasma SFA to PUFA ratio. Genes involved in lipid metabolism were differentially expressed in PBMCs depending on the plasma fatty acid levels. This finding may increase our understanding of how fatty acids influence lipid metabolism at a molecular level in humans.

  1. Rab11-dependent Recycling of the Human Ether-a-go-go-related Gene (hERG) Channel*

    PubMed Central

    Chen, Jeffery; Guo, Jun; Yang, Tonghua; Li, Wentao; Lamothe, Shawn M.; Kang, Yudi; Szendrey, John A.; Zhang, Shetuan

    2015-01-01

    The human ether-a-go-go-related gene (hERG) encodes the pore-forming subunit of the rapidly activating delayed rectifier potassium channel (IKr). A reduction in the hERG current causes long QT syndrome, which predisposes affected individuals to ventricular arrhythmias and sudden death. We reported previously that hERG channels in the plasma membrane undergo vigorous internalization under low K+ conditions. In the present study, we addressed whether hERG internalization occurs under normal K+ conditions and whether/how internalized channels are recycled back to the plasma membrane. Using patch clamp, Western blot, and confocal imaging analyses, we demonstrated that internalized hERG channels can effectively recycle back to the plasma membrane. Low K+-enhanced hERG internalization is accompanied by an increased rate of hERG recovery in the plasma membrane upon reculture following proteinase K-mediated clearance of cell-surface proteins. The increased recovery rate is not due to enhanced protein synthesis, as hERG mRNA expression was not altered by low K+ exposure, and the increased recovery was observed in the presence of the protein biosynthesis inhibitor cycloheximide. GTPase Rab11, but not Rab4, is involved in the recycling of hERG channels. Interfering with Rab11 function not only delayed hERG recovery in cells after exposure to low K+ medium but also decreased hERG expression and function in cells under normal culture conditions. We concluded that the recycling pathway plays an important role in the homeostasis of plasma membrane-bound hERG channels. PMID:26152716

  2. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    PubMed

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Superparamagnetic graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of tamsulosin hydrochloride in human plasma by high performance liquid chromatography-ultraviolet detection.

    PubMed

    Pashaei, Yaser; Ghorbani-Bidkorbeh, Fatemeh; Shekarchi, Maryam

    2017-05-26

    In the present study, superparamagnetic graphene oxide-Fe 3 O 4 nanocomposites were successfully prepared by a modified impregnation method (MGO mi ) and their application as a sorbent in the magnetic-dispersive solid phase extraction (M-dSPE) mode to the preconcentration and determination of tamsulosin hydrochloride (TMS) in human plasma was investigated by coupling with high performance liquid chromatography-ultraviolet detection (HPLC-UV). The structure, morphology and magnetic properties of the prepared nanocomposites were characterized using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and vibrating sample magnetometry (VSM). Some factors affecting the extraction efficiency, including the pH value, amount of sorbent, extraction time, elution solvent and its volume, and desorption time were studied and optimized. Magnetic nanocomposites plasma extraction of TMS following HPLC analyses showed a linear calibration curve in the range of 0.5-50.0ngmL -1 with an acceptable correlation coefficient (R 2 =0.9988). The method was sensitive, with a low limit of detection (0.17ngmL -1 ) and quantification (0.48ngmL -1 ). Inter- and intra-day precision expressed as relative standard deviation (n=3) and the preconcentration factor, were found to be 5.6-7.2%, 2.9-4.2% and 10, respectively. Good recoveries (98.1-101.4%) with low relative standard deviations (4.2-5.0%) indicated that the matrices under consideration do not significantly affect the extraction process. Due to its high precision and accuracy, the developed method may be a HPLC-UV alternative with M-dSPE for bioequivalence analysis of TMS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Development of a microplate coagulation assay for Factor V in human plasma.

    PubMed

    Tilley, Derek; Levit, Irina; Samis, John A

    2011-06-28

    Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement of the functional coagulation activity of FV in human plasma.

  5. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  6. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  7. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  8. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  9. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  10. The Complex Exogenous RNA Spectra in Human Plasma: An Interface with Human Gut Biota?

    PubMed Central

    Wang, Kai; Li, Hong; Yuan, Yue; Etheridge, Alton; Zhou, Yong; Huang, David; Wilmes, Paul; Galas, David

    2012-01-01

    Human plasma has long been a rich source for biomarker discovery. It has recently become clear that plasma RNA molecules, such as microRNA, in addition to proteins are common and can serve as biomarkers. Surveying human plasma for microRNA biomarkers using next generation sequencing technology, we observed that a significant fraction of the circulating RNA appear to originate from exogenous species. With careful analysis of sequence error statistics and other controls, we demonstrated that there is a wide range of RNA from many different organisms, including bacteria and fungi as well as from other species. These RNAs may be associated with protein, lipid or other molecules protecting them from RNase activity in plasma. Some of these RNAs are detected in intracellular complexes and may be able to influence cellular activities under in vitro conditions. These findings raise the possibility that plasma RNAs of exogenous origin may serve as signaling molecules mediating for example the human-microbiome interaction and may affect and/or indicate the state of human health. PMID:23251414

  11. Simultaneous measurement of proguanil and its metabolites in human plasma and urine by reversed-phase high-performance liquid chromatography, and its preliminary application in relation to genetically determined S-mephenytoin 4'-hydroxylation status.

    PubMed

    Kusaka, M; Setiabudy, R; Chiba, K; Ishizaki, T

    1996-02-01

    A simple high-performance liquid chromatographic (HPLC) assay method was developed for the measurement of proguanil (PG) and its major metabolites, cycloguanil (CG) and 4-chlorophenyl-biguanide (CPB), in human plasma and urine. The assay allowed the simultaneous determination of all analytes in 1 ml of plasma or 0.1 ml of urine. The detection limits of PG, CG, and CPB, defined as the signal-to-noise ratio of 3, were 1 and 5 ng/ml for plasma and urine samples, respectively. Recoveries of the analytes and the internal standard (pyrimethamine) were > 62% from plasma and > 77% from urine. Intra-assay and interassay coefficients of variation for all analytes in plasma and urine were < 10% except for the values of CG and CPB, which ranged from 10% to 15% at one or two concentrations among 4-5 concentrations studied. The clinical applicability of the method was assessed by the preliminary pharmacokinetic study of PG, CG, and CPB in six healthy volunteers with the individually known phenotypes (extensive and poor metabolizers) of S-mephenytoin 4'-hydroxylation, suggesting that individuals with a poor metabolizer phenotype of S-mephenytoin have a much lower capacity to bioactivate PG to CG compared with the extensive metabolizers.

  12. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    PubMed

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  13. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    PubMed

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87

  14. Sorptive thin film microextraction followed by direct solid state spectrofluorimetry: A simple, rapid and sensitive method for determination of carvedilol in human plasma.

    PubMed

    Karimi, Shima; Talebpour, Zahra; Adib, Noushin

    2016-06-14

    A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Simultaneous determination of atorvastatin and valsartan in human plasma by solid-based disperser liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection.

    PubMed

    Farajzadeh, Mir Ali; Khorram, Parisa; Pazhohan, Azar

    2016-04-01

    A simple, sensitive, and efficient method has been developed for simultaneous estimation of valsartan and atorvastatin in human plasma by combination of solid-based dispersive liquid-liquid microextraction and high performance liquid chromatography-diode array detection. In the proposed method, 1,2-dibromoethane (extraction solvent) is added on a sugar cube (as a solid disperser) and it is introduced into plasma sample containing the analytes. After manual shaking and centrifugation, the resultant sedimented phase is subjected to back extraction into a small volume of sodium hydrogen carbonate solution using air-assisted liquid-liquid microextraction. Then the cloudy solution is centrifuged and the obtained aqueous phase is transferred into a microtube and analyzed by the separation system. Under the optimal conditions, extraction recoveries are obtained in the range of 81-90%. Calibration curves plotted in drug-free plasma sample are linear in the ranges of 5-5000μgL(-1) for valsartan and 10-5000μgL(-1) for atorvastatin with the coefficients of determination higher than 0.997. Limits of detection and quantification of the studied analytes in plasma sample are 0.30-2.6 and 1.0-8.2μgL(-1), respectively. Intra-day (n=6) and inter-days (n=4) precisions of the method are satisfactory with relative standard deviations less than 7.4% (at three levels of 10, 500, and 2000μgL(-1), each analyte). These data suggest that the method can be successfully applied to determine trace amounts of valsartan and atorvastatin in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Quantification of nerve agent VX-butyrylcholinesterase adduct biomarker from an accidental exposure.

    PubMed

    Solano, Maria I; Thomas, Jerry D; Taylor, James T; McGuire, Jeffrey M; Jakubowski, Edward M; Thomson, Sandra A; Maggio, Vincent L; Holland, Kerry E; Smith, J Richard; Capacio, Benedict; Woolfitt, Adrian R; Ashley, David L; Barr, John R

    2008-01-01

    The lack of data in the open literature on human exposure to the nerve agent O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) gives a special relevance to the data presented in this study in which we report the quantification of VX-butyrylcholinesterase adduct from a relatively low-level accidental human exposure. The samples were analyzed by gas chromatography-high resolution mass spectrometry using the fluoride ion regeneration method for the quantification of multiple nerve agents including VX. Six human plasma samples from the same individual were collected after the patient had been treated once with oxime immediately after exhibiting signs of exposure. Detection limits of approximately 5.5 pg/mL plasma were achieved for the G-analogue of VX (G-VX). Levels of the G-VX ranged from 81.4 pg/mL on the first day after the exposure to 6.9 pg/mL in the sample taken 27 days after the exposure. Based on the reported concentration of human butyrylcholinesterase in plasma of approximately 80 nM, it can be calculated that inhibition levels of >or= 0.05% of BuChE can be accurately quantified. These data further indicate that the fluoride ion regeneration method is a potentially powerful tool that can be used to assess low-level exposure to VX.

  17. The novel combination of theophylline and bambuterol as a potential treatment of hypoxemia in humans.

    PubMed

    Strand, Trond-Eirik; Khiabani, Hasse Z; Boico, Alina; Radiloff, Daniel; Zhao, Yulin; Hamilton, Karyn L; Christians, Uwe; Klawitter, Jelena; Noveck, Robert J; Piantadosi, Claude A; Bell, Christopher; Irwin, David; Schroeder, Thies

    2017-09-01

    Hypoxemia can be life-threatening, both acutely and chronically. Because hypoxemia causes vascular dysregulation that further restricts oxygen availability to tissue, it can be pharmacologically addressed. We hypothesized that theophylline can be safely combined with the β2-adrenergic vasodilator bambuterol to improve oxygen availability in hypoxemic patients. Ergogenicity and hemodynamic effects of bambuterol and theophylline were measured in rats under hypobaric and normobaric hypoxia (12% O 2 ). Feasibility in humans was assessed using randomized, double-blind testing of the influence of combined slow-release theophylline (300 mg) and bambuterol (20 mg) on adverse events (AEs), plasma K + , pulse, blood pressure, and drug interaction. Both drugs and their combination significantly improved hypoxic endurance in rats. In humans, common AEs were low K + (<3.5 mmol/L; bambuterol: 12, theophylline: 4, combination: 13 episodes) and tremors (10, 0, 14 episodes). No exacerbation or serious AE occurred when drugs were combined. A drop in plasma K + coincided with peak bambuterol plasma concentrations. Bambuterol increased heart rate by approximately 13 bpm. Drug interaction was present but small. We report promise, feasibility, and relative safety of combined theophylline and bambuterol as a treatment of hypoxemia in humans. Cardiac safety and blood K + will be important safety endpoints when testing these drugs in hypoxemic subjects.

  18. Exploring the human seminal plasma proteome: an unexplored gold mine of biomarker for male infertility and male reproduction disorder.

    PubMed

    Gilany, Kambiz; Minai-Tehrani, Arash; Savadi-Shiraz, Elham; Rezadoost, Hassan; Lakpour, Niknam

    2015-01-01

    The human seminal fluid is a complex body fluid. It is not known how many proteins are expressed in the seminal plasma; however in analog with the blood it is possible up to 10,000 proteins are expressed in the seminal plasma. The human seminal fluid is a rich source of potential biomarkers for male infertility and reproduction disorder. In this review, the ongoing list of proteins identified from the human seminal fluid was collected. To date, 4188 redundant proteins of the seminal fluid are identified using different proteomics technology, including 2-DE, SDS-PAGE-LC-MS/MS, MudPIT. However, this was reduced to a database of 2168 non-redundant protein using UniProtKB/Swiss-Prot reviewed database. The core concept of proteome were analyzed including pI, MW, Amino Acids, Chromosome and PTM distribution in the human seminal plasma proteome. Additionally, the biological process, molecular function and KEGG pathway were investigated using DAVID software. Finally, the biomarker identified in different male reproductive system disorder was investigated using proteomics platforms so far. In this study, an attempt was made to update the human seminal plasma proteome database. Our finding showed that human seminal plasma studies used to date seem to have converged on a set of proteins that are repeatedly identified in many studies and that represent only a small fraction of the entire human seminal plasma proteome.

  19. Concurrent profiling of polar metabolites and lipids in human plasma using HILIC-FTMS

    NASA Astrophysics Data System (ADS)

    Cai, Xiaoming; Li, Ruibin

    2016-11-01

    Blood plasma is the most popularly used sample matrix for metabolite profiling studies, which aim to achieve global metabolite profiling and biomarker discovery. However, most of the current studies on plasma metabolite profiling focused on either the polar metabolites or lipids. In this study, a comprehensive analysis approach based on HILIC-FTMS was developed to concurrently examine polar metabolites and lipids. The HILIC-FTMS method was developed using mixed standards of polar metabolites and lipids, the separation efficiency of which is better in HILIC mode than in C5 and C18 reversed phase (RP) chromatography. This method exhibits good reproducibility in retention times (CVs < 3.43%) and high mass accuracy (<3.5 ppm). In addition, we found MeOH/ACN/Acetone (1:1:1, v/v/v) as extraction cocktail could achieve desirable gathering of demanded extracts from plasma samples. We further integrated the MeOH/ACN/Acetone extraction with the HILIC-FTMS method for metabolite profiling and smoking-related biomarker discovery in human plasma samples. Heavy smokers could be successfully distinguished from non smokers by univariate and multivariate statistical analysis of the profiling data, and 62 biomarkers for cigarette smoke were found. These results indicate that our concurrent analysis approach could be potentially used for clinical biomarker discovery, metabolite-based diagnosis, etc.

  20. In vitro degradation of neurotensin in human plasma.

    PubMed

    Lee, Y C; Uttenthal, L O; Smith, H A; Bloom, S R

    1986-01-01

    To study the degradation of neurotensin in plasma in vitro, fresh human plasma was incubated with neurotensin in the presence and absence of the peptidase inhibitors pepstatin A, EDTA, PMSF and aprotinin. The half-time of disappearance of neurotensin at 37 degrees C was calculated to be 226 min in vitro as opposed to 1.4 min in vivo when measured by radioimmunoassay with a C-terminally directed neurotensin antiserum. Both gel filtration and reversed phase high-pressure liquid chromatography (HPLC) showed that the main degradation product of neurotensin in human plasma in vitro was chromatographically and immunologically identical to neurotensin 1-8 and HPLC also demonstrated the formation of neurotensin 1-11. The loss of neurotensin incubated in human plasma in vitro was greatly reduced by EDTA but not by the other peptidase inhibitors tested. In this respect peptidase(s) responsible for the degradation of neurotensin in plasma differ from those present in brain homogenates. EDTA may be of importance in the preservation of neurotensin in plasma samples.

  1. [Human bioaging acceleration as Chernobyl radiation consequence].

    PubMed

    Neĭfakh, E A; Liuman, G K

    2013-01-01

    To monitor human bioaging as a health integral index by blood plasma markers as a molar ratio for biochemically coupled monomers of intracellular lipofuscin, an intracellular polymeric aging pigment with free-radical crossed shifts, has been developed. Lipofuscin includes cell debris with catabolites of lipoperoxic cascade and lipid antioxidants. The latter were detected in the plasma samples of normal adults and children, as well as in Chernobyl clean-up workers (24-62 years old by 1990) with external total gamma-doses of 0.9-145 cSv for 4.2 years. Dynamics for bioaging markers as the molar ratio of blood levels of lipoperoxic catabolites to their antioxidants reflected normal physiologic peculiarities for the studied age periods: oxygen stress for newborns, adaptation during childhood, stability for the middle age and an increased lipoperoxidation (mainly for aging men) due to the age weakening of the antioxidant control. The ratio for the fractions of ma- lone dialdehyde (MDA), a lipoperoxic final catabolite, showed the increase of its binding by plasma proteins in proportions to calendar ages for the norm, as it is the case for lipofuscin; The graph of the age normal molar ratio of protein-bound MDA to the free one was pre-set for calibrations into the developed computer Program to calculate Relative Aging Velocities (Wrel) by bioage increments during the period of human exposure to radiation from the CAPS damage. Wrel were increasing logarithmically to the obtained doses if the total radiation exceeded 4 cSv and exceeded their normal velocities at 50 cSv 10 times or more. Slowing down of Wrel in relation to the calendar age increment was found if the sum doses were lower than 4 cSv. Levels of the studied plasma metabolites as their bioage Moles/Moles markers relative to their norms are dynamically stationary in contrast to the lipofuscin intracellular irreversible accumulation. Earlier it was shown that the decreased vitamin E and A levels with the increased lipoperoxic metabolite blood levels that indicate health consequences for the irradiated CAPS personell with related cytogenetic deviations, as well as for the adult population and children from radio-polluted regions, were restored to norms or corrected by adequate peroral therapy with bioantioxidants.

  2. Prediction of Human Pharmacokinetic Profile After Transdermal Drug Application Using Excised Human Skin.

    PubMed

    Yamamoto, Syunsuke; Karashima, Masatoshi; Arai, Yuta; Tohyama, Kimio; Amano, Nobuyuki

    2017-09-01

    Although several mathematical models have been reported for the estimation of human plasma concentration profiles of drug substances after dermal application, the successful cases that can predict human pharmacokinetic profiles are limited. Therefore, the aim of this study is to investigate the prediction of human plasma concentrations after dermal application using in vitro permeation parameters obtained from excised human skin. The in vitro skin permeability of 7 marketed drug products was evaluated. The plasma concentration-time profiles of the drug substances in humans after their dermal application were simulated using compartment models and the clinical pharmacokinetic parameters. The transdermal process was simulated using the in vitro skin permeation rate and lag time assuming a zero-order absorption. These simulated plasma concentration profiles were compared with the clinical data. The result revealed that the steady-state plasma concentration of diclofenac and the maximum concentrations of nicotine, bisoprolol, rivastigmine, and lidocaine after topical application were within 2-fold of the clinical data. Furthermore, the simulated concentration profiles of bisoprolol, nicotine, and rivastigmine reproduced the decrease in absorption due to drug depletion from the formulation. In conclusion, this simple compartment model using in vitro human skin permeation parameters as zero-order absorption predicted the human plasma concentrations accurately. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  3. Plasma Amyloid Is Associated with White Matter and Subcortical Alterations and Is Modulated by Age and Seasonal Rhythms in Mouse Lemur Primates.

    PubMed

    Gary, Charlotte; Hérard, Anne-Sophie; Hanss, Zoé; Dhenain, Marc

    2018-01-01

    Accumulation of amyloid-β (Aβ) peptides in the brain is a critical early event in the pathogenesis of Alzheimer's disease (AD), the most common age-related neurodegenerative disorder. There is increasing interest in measuring levels of plasma Aβ since this could help in diagnosis of brain pathology. However, the value of plasma Aβ in such a diagnosis is still controversial and factors modulating its levels are still poorly understood. The mouse lemur ( Microcebus murinus ) is a primate model of cerebral aging which can also present with amyloid plaques and whose Aβ is highly homologous to humans'. In an attempt to characterize this primate model and to evaluate the potential of plasma Aβ as a biomarker for brain alterations, we measured plasma Aβ 40 concentration in 21 animals aged from 5 to 9.5 years. We observed an age-related increase in plasma Aβ 40 levels. We then evaluated the relationships between plasma Aβ 40 levels and cerebral atrophy in these mouse lemurs. Voxel-based analysis of cerebral MR images (adjusted for the age/sex/brain size of the animals), showed that low Aβ 40 levels are associated with atrophy of several white matter and subcortical brain regions. These results suggest that low Aβ 40 levels in middle-aged/old animals are associated with brain deterioration. One special feature of mouse lemurs is that their metabolic and physiological parameters follow seasonal changes strictly controlled by illumination. We evaluated seasonal-related variations of plasma Aβ 40 levels and found a strong effect, with higher plasma Aβ 40 concentrations in winter conditions compared to summer. This question of seasonal modulation of Aβ plasma levels should be addressed in clinical studies. We also focused on the amplitude of the difference between plasma Aβ 40 levels during the two seasons and found that this amplitude increases with age. Possible mechanisms leading to these seasonal changes are discussed.

  4. Identification of neurotensin-related peptides in human thymic epithelial cell membranes and relationship with major histocompatibility complex class I molecules.

    PubMed

    Vanneste, Y; Thome, A N; Vandersmissen, E; Charlet, C; Franchimont, D; Martens, H; Lhiaubet, A M; Schimpff, R M; Rostène, W; Geenen, V

    1997-06-01

    This study shows the expression at the cell surface of human thymic epithelial cells (TEC) of a neurotensin (NT)-like immunoreactivity. NT radio-immunoassay (RIA) revealed that cultured human TEC contain +/-5 ng immunoreactive (ir) NT/10(6) cells, of which 5% is associated with plasma cell membranes. HPLC analysis of NT-ir present in human TEC showed a major peak of NT-ir corresponding to NT1-13. NT-ir was not detected in the supernatant of human TEC cultures. Using an affinity column prepared with a anti-MHC class I monoclonal antibody, NT-ir-related peptides were retained on the column and eluted together with MHC class I-related proteins. According to the elution time on HPLC of these peptides, they correspond to intact NT1-13, as well as to smaller fragments of NT1-13.

  5. Effect of a protein-rich meal on urinary and salivary free amino acid concentrations in human subjects.

    PubMed

    Brand, H S; Jörning, G G; Chamuleau, R A; Abraham-Inpijn, L

    1997-08-08

    The aim of the present study was to investigate whether in healthy volunteers acute changes in plasma free amino acid composition after a protein-rich test meal are reflected in the urinary and salivary concentrations of the corresponding amino acids. The ingestion of a protein-rich meal elicited a significant increase of plasma and urine amino acid concentrations. The postprandial salivary amino acid excretion showed only minor changes. For several amino acids (alanine, arginine, asparagine, glycine, threonine and valine) significant relations were observed between the increase in concentration of these amino acids in venous plasma and urine. In whole saliva, only threonine and valine showed a significant relationship with the corresponding plasma concentration. Our data suggest that the urinary amino acid excretion of several amino acids has the potential for estimating short-term changes in plasma concentrations. Determination of salivary amino acid concentrations seems less appropriate for this purpose.

  6. Sensitive determination of three aconitum alkaloids and their metabolites in human plasma by matrix solid-phase dispersion with vortex-assisted dispersive liquid-liquid microextraction and HPLC with diode array detection.

    PubMed

    Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri

    2016-05-01

    A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A validated LC-MS/MS method for the quantitative measurement of creatinine as an endogenous biomarker in human plasma.

    PubMed

    Zhao, Yue; Liu, Guowen; Angeles, Aida; Christopher, Lisa J; Wang, Zhaoqing; Arnold, Mark E; Shen, Jim X

    2016-10-01

    Creatinine is an endogenous compound generated from creatine by normal muscular metabolism. It is an important indicator of renal function and the serum level is routinely monitored in clinical labs. Results & methodology: Surrogate analyte (d3-creatinine) was used for calibration standard and quality control preparation and the relative instrument response ratio between creatinine and d3-creatinine was used to calculate the endogenous creatinine concentrations. A fit-for-purpose strategy of using a surrogate analyte and authentic matrix was adopted for this validation. The assay was the first human plasma assay using such strategy and was successfully applied to a clinical study to confirm a transient elevation of creatinine observed using an existing clinical assay.

  8. Evaluation of a disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) activity enzyme-linked immunosorbent assay for measuring plasma ADAMTS13 activity in dogs.

    PubMed

    Maruyama, Haruhiko; Kaneko, Michiko; Otake, Taiga; Kano, Rui; Yamaya, Yoshiki; Watari, Toshihiro; Hasegawa, Atsuhiko; Kamata, Hiroshi

    2014-03-01

    A disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) is a von Willebrand factor (vWF)-cleaving protease. Deficiencies in ADAMTS13 activity are known to cause thrombotic diseases in human beings. The present study evaluated whether the human ADAMTS13 activity enzyme-linked immunosorbent assay (ELISA) kit containing human vWF73 (a minimal substrate) and anti-N10 antibody (which specifically recognizes the decapeptide of the C-terminal edge of cleaved vWF by human ADAMTS13) is applicable to the measurement of canine plasma ADAMTS13 activity. Human vWF73 fused with a GST-tag and a His-tag (GST-hvWF73-His) was reacted with recombinant canine (rc)ADAMTS13, canine plasma, and human plasma, and then used in Western blotting using anti-N10 antibody. Linearity and intra- and interassay reproducibility of the human ADAMTS13 activity ELISA kit in canine plasma were further evaluated. Finally, plasma ADAMTS13 activity was measured in 13 healthy dogs and 6 dogs with bacteremia using the human ADAMTS13 activity ELISA kit. Cleaved products with a 28-kDa GST-hvWF73-His were detected specifically in rcADAMTS13 as well as in human ADAMTS13, and also in canine plasma by anti-N10 antibody, showing excellent linearity. Intra-assay coefficient of variation (CV) was 3.0-12.4%, and interassay CV was 11.5-12.5%. The ADAMTS13 activity was significantly lower in dogs with bacteremia than in healthy dogs (P = 0.0025). The current study revealed that the human ADAMTS13 activity ELISA kit is applicable for measurement of canine plasma ADAMTS13 activity to elucidate the pathology of thrombotic diseases in dogs.

  9. Pathogen Reduction in Human Plasma Using an Ultrashort Pulsed Laser

    PubMed Central

    Tsen, Shaw-Wei D.; Kingsley, David H.; Kibler, Karen; Jacobs, Bert; Sizemore, Sara; Vaiana, Sara M.; Anderson, Jeanne; Tsen, Kong-Thon; Achilefu, Samuel

    2014-01-01

    Pathogen reduction is a viable approach to ensure the continued safety of the blood supply against emerging pathogens. However, the currently licensed pathogen reduction techniques are ineffective against non-enveloped viruses such as hepatitis A virus, and they introduce chemicals with concerns of side effects which prevent their widespread use. In this report, we demonstrate the inactivation of both enveloped and non-enveloped viruses in human plasma using a novel chemical-free method, a visible ultrashort pulsed laser. We found that laser treatment resulted in 2-log, 1-log, and 3-log reductions in human immunodeficiency virus, hepatitis A virus, and murine cytomegalovirus in human plasma, respectively. Laser-treated plasma showed ≥70% retention for most coagulation factors tested. Furthermore, laser treatment did not alter the structure of a model coagulation factor, fibrinogen. Ultrashort pulsed lasers are a promising new method for chemical-free, broad-spectrum pathogen reduction in human plasma. PMID:25372037

  10. Simultaneous determination of nicotine, cotinine, and nicotine N-oxide in human plasma, semen, and sperm by LC-Orbitrap MS.

    PubMed

    Abu-Awwad, Ahmad; Arafat, Tawfiq; Schmitz, Oliver J

    2016-09-01

    Nicotine (Nic) distribution in human fluids and tissues has a deleterious effect on human health. In addition to its poisoning profile, Nic may contribute to the particular impact of smoking on human reproduction. Although present in seminal fluid, still nobody knows whether nicotine is available in sperm or not. Herein, we developed and validated a new bioanalytical method, for simultaneous determination of Nic, cotinine (Cot), and nicotine N'-oxide (Nox) in human plasma, semen, and sperm by LC-ESI-orbitrap-MS. Blood and semen samples were collected from 12 healthy smoking volunteers in this study. Sperm bodies were then separated quantitatively from 1 mL of semen samples by centrifugation. The developed method was fully validated for plasma following European and American guidelines for bioanalytical method validation, and partial validation was applied to semen analysis. Plasma, semen, and sperm samples were treated by trichloroacetic acid solution for protein direct precipitation in single extraction step. The established calibration range for Nic and Nox in plasma and semen was linear between 5 and 250 ng/mL, and for Cot between 10 and 500 ng/mL. Nic and Cot were detected in human sperm at concentrations as high as in plasma. In addition, Nox was present in semen and sperm but not in plasma. Graphical abstract Nicotine correlation between plasma and semen a; Nicotine correlation between semen and sperm c; Cotinine correlation between plasma and semen b; Cotinine correlation between semen and sperm d.

  11. Increased MMP-9 and TIMP-1 in mouse neonatal brain and plasma and in human neonatal plasma after hypoxia-ischemia: a potential marker of neonatal encephalopathy.

    PubMed

    Bednarek, Nathalie; Svedin, Pernilla; Garnotel, Roselyne; Favrais, Géraldine; Loron, Gauthier; Schwendiman, Leslie; Hagberg, Henrik; Morville, Patrice; Mallard, Carina; Gressens, Pierre

    2012-01-01

    To implement neuroprotective strategies in newborns, sensitive and specific biomarkers are needed for identifying those who are at risk for brain damage. We evaluated the effectiveness of matrix metalloproteinases (MMPs) and their naturally occurring tissue inhibitors of metalloproteinases (TIMPs) in predicting neonatal encephalopathy (NE) damage in newborns. Plasma MMP-9 and TIMP-1 levels were upregulated as early as 1 h after the HI insult but not did not show such elevations after other types of injury (ibotenate-induced excitotoxicity, hypoxia, lipopolysaccharide-induced inflammation), and brain levels reflected this increase soon thereafter. We confirmed these results by carrying out plasma MMP-9 and TIMP-1 measurements in human newborns with NE. In these infants, protein levels of MMP-9 and TIMP-1 were found to be elevated during a short window up to 6 h after birth. This feature is particularly useful in identifying newborns in need of neuroprotection. A second peak observed 72 h after birth is possibly related to the second phase of energy failure after a HI insult. Our data, although preliminary, support the use of MMP-9 and TIMP-1 as early biomarkers for the presence and extent of perinatal brain injury in human term newborns. We first used a mouse model of neonatal HI injury to explore mechanistic aspects such as the time course of these markers after the hypoxia-ischemia event, and the correlation between the levels of these candidate markers in brain and plasma.

  12. Pharmacokinetics of anthocyanins and antioxidant effects after the consumption of anthocyanin-rich acai juice and pulp (Euterpe oleracea Mart.) in human healthy volunteers.

    PubMed

    Mertens-Talcott, Susanne U; Rios, Jolian; Jilma-Stohlawetz, Petra; Pacheco-Palencia, Lisbeth A; Meibohm, Bernd; Talcott, Stephen T; Derendorf, Hartmut

    2008-09-10

    The acai berry is the fruit of the acai palm and is traditionally consumed in Brazil but has gained popularity abroad as a food and functional ingredient, yet little information exists on its health effect in humans. This study was performed as an acute four-way crossover clinical trial with acai pulp and clarified acai juice compared to applesauce and a non-antioxidant beverage as controls. Healthy volunteers (12) were dosed at 7 mL/kg of body weight after a washout phase and overnight fast, and plasma was repeatedly sampled over 12 h and urine over 24 h after consumption. Noncompartmental pharmacokinetic analysis of total anthocyanins quantified as cyanidin-3-O-glucoside showed Cmax values of 2321 and 1138 ng/L at t max times of 2.2 and 2.0 h, and AUC last values of 8568 and 3314 ng h L(-1) for pulp and juice, respectively. Nonlinear mixed effect modeling identified dose volume as a significant predictor of relative oral bioavailability in a negative nonlinear relationship for acai pulp and juice. Plasma antioxidant capacity was significantly increased by the acai pulp and applesauce. Individual increases in plasma antioxidant capacity of up to 2.3- and 3-fold for acai juice and pulp, respectively were observed. The antioxidant capacity in urine, generation of reactive oxygen species, and uric acid concentrations in plasma were not significantly altered by the treatments. Results demonstrate the absorption and antioxidant effects of anthocyanins in acai in plasma in an acute human consumption trial.

  13. Nanoscale control of energy and matter in plasma-surface interactions: towards energy-efficient nanotech

    NASA Astrophysics Data System (ADS)

    Ostrikov, Kostya

    2010-11-01

    This presentation focuses on the plasma issues related to the solution of the grand challenge of directing energy and matter at nanoscales. This ability is critical for the renewable energy and energy-efficient technologies for sustainable future development. It will be discussed how to use environmentally and human health benign non-equilibrium plasma-solid systems and control the elementary processes of plasma-surface interactions to direct the fluxes of energy and matter at multiple temporal and spatial scales. In turn, this makes it possible to achieve the deterministic synthesis of self- organised arrays of metastable nanostructures in the size range beyond the reach of the present-day nanofabrication. Such structures have tantalising prospects to enhance performance of nanomaterials in virtually any area of human activity yet remain almost inaccessible because the Nature's energy minimisation rules allow only a small number of stable equilibrium states. By using precisely controlled and kinetically fast nanoscale transfer of energy and matter under non-equilibrium conditions and harnessing numerous plasma- specific controls of species creation, delivery to the surface, nucleation and large-scale self-organisation of nuclei and nanostructures, the arrays of metastable nanostructures can be created, arranged, stabilised, and further processed to meet the specific requirements of the envisaged applications. These approaches will eventually lead to faster, unprecedentedly- clean, human-health-friendly, and energy-efficient nanoscale synthesis and processing technologies for the next-generation renewable energy and light sources, biomedical devices, information and communication systems, as well as advanced functional materials for applications ranging from basic food, water, health and clean environment needs to national security and space missions.

  14. Non-thermal Plasma Activates Human Keratinocytes by Stimulation of Antioxidant and Phase II Pathways

    PubMed Central

    Schmidt, Anke; Dietrich, Stephan; Steuer, Anna; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Masur, Kai; Wende, Kristian

    2015-01-01

    Non-thermal atmospheric pressure plasma provides a novel therapeutic opportunity to control redox-based processes, e.g. wound healing, cancer, and inflammatory diseases. By spatial and time-resolved delivery of reactive oxygen and nitrogen species, it allows stimulation or inhibition of cellular processes in biological systems. Our data show that both gene and protein expression is highly affected by non-thermal plasma. Nuclear factor erythroid-related factor 2 (NRF2) and phase II enzyme pathway components were found to act as key controllers orchestrating the cellular response in keratinocytes. Additionally, glutathione metabolism, which is a marker for NRF2-related signaling events, was affected. Among the most robustly increased genes and proteins, heme oxygenase 1, NADPH-quinone oxidoreductase 1, and growth factors were found. The roles of NRF2 targets, investigated by siRNA silencing, revealed that NRF2 acts as an important switch for sensing oxidative stress events. Moreover, the influence of non-thermal plasma on the NRF2 pathway prepares cells against exogenic noxae and increases their resilience against oxidative species. Via paracrine mechanisms, distant cells benefit from cell-cell communication. The finding that non-thermal plasma triggers hormesis-like processes in keratinocytes facilitates the understanding of plasma-tissue interaction and its clinical application. PMID:25589789

  15. Isolation of Plasma Membrane Vesicles from Mouse Placenta at Term and Measurement of System A and System β Amino Acid Transporter Activity

    PubMed Central

    Kusinski, L.C.; Jones, C.J.P.; Baker, P.N.; Sibley, C.P.; Glazier, J.D.

    2010-01-01

    Placental amino acid transport is essential for optimal fetal growth and development, with a reduced fetal provision of amino acids being implicated as a potential cause of fetal growth restriction (FGR). Understanding placental insufficiency related FGR has been aided by the development of mouse models that have features of the human disease. However, to take maximal advantage of these, methods are required to study placental function in the mouse. Here, we report a method to isolate plasma membrane vesicles from mouse placenta near-term and have used these to investigate two amino acid transporters, systems A and β, the activities of which are reduced in human placental microvillous plasma membrane (MVM) vesicles from FGR pregnancies. Plasma membrane vesicles were isolated at embryonic day 18 by a protocol involving homogenisation, MgCl2 precipitation and centrifugation. Vesicles were enriched 11.3 ± 0.5-fold in alkaline phosphatase activity as compared to initial homogenate, with minimal intracellular organelle contamination as judged by marker analyses. Cytochemistry revealed alkaline phosphatase was localised between trophoblast layers I and II, with intense reaction product deposited on the maternal-facing plasma membrane of layer II, suggesting that vesicles were derived from this trophoblast membrane. System A and system β activity in mouse placental vesicles, measured as Na+-dependent uptake of 14C-methylaminoisobutyric acid (MeAIB) and 3H-taurine respectively confirmed localisation of these transporters to the maternal-facing plasma membrane of layer II. Comparison to human placental MVM showed that system A activity was comparable at initial rate between species whilst system β activity was significantly lower in mouse. This mirrored the lower expression of TAUT observed in mouse placental vesicles. We conclude that syncytiotrophoblast layer II-derived plasma membrane vesicles can be isolated and used to examine transporter function. PMID:19954844

  16. Simultaneous quantitation of acetylsalicylic acid and clopidogrel along with their metabolites in human plasma using liquid chromatography tandem mass spectrometry.

    PubMed

    Chhonker, Yashpal S; Pandey, Chandra P; Chandasana, Hardik; Laxman, Tulsankar Sachin; Prasad, Yarra Durga; Narain, V S; Dikshit, Madhu; Bhatta, Rabi S

    2016-03-01

    The interest in therapeutic drug monitoring has increased over the last few years. Inter- and intra-patient variability in pharmacokinetics, plasma concentration related toxicity and success of therapy have stressed the need of frequent therapeutic drug monitoring of the drugs. A sensitive, selective and rapid liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of acetylsalicylic acid (aspirin), salicylic acid, clopidogrel and carboxylic acid metabolite of clopidogrel in human plasma. The chromatographic separations were achieved on Waters Symmetry Shield(TM) C18 column (150 × 4.6 mm, 5 µm) using 3.5 mm ammonium acetate (pH 3.5)-acetonitrile (10:90, v/v) as mobile phase at a flow rate of 0.75 mL/min. The present method was successfully applied for therapeutic drug monitoring of aspirin and clopidogrel in 67 patients with coronary artery disease. Copyright © 2015 John Wiley & Sons, Ltd.

  17. In vitro chronic effects on hERG channel caused by the marine biotoxin Azaspiracid-2

    PubMed Central

    Ferreiro, Sara F.; Vilariño, Natalia; Louzao, M.Carmen; Nicolaou, K. C.; Frederick, Michael O.; Botana, Luis M.

    2014-01-01

    Azaspiracids (AZAs) are marine biotoxins produced by the dinoflagellate Azadinium spinosum that accumulate in many shellfish species. Azaspiracid poisoning caused by AZA-contaminated seafood consumption is primarily manifested by diarrhea in humans. To protect human health, AZA-1, AZA-2 and AZA-3 content in seafood has been regulated by food safety authorities in many countries. Recently AZAs have been reported as a low/moderate hERG channel blockers. Furthermore AZA-2 has been related to arrhythmia appearance in rats, suggesting potential heart toxicity. In this study AZA-2 in vitro effects on hERG channel after chronic exposure are analyzed to further explore potential cardiotoxicity. The amount of hERG channel in the plasma membrane, hERG channel trafficking and hERG currents were evaluated up to 12 h of toxin exposure. In these conditions AZA-2 caused an increase of hERG levels in the plasma membrane, probably related to hERG retrograde trafficking impairment. Although this alteration did not translate into an increase of hERG channel-related current, more studies will be necessary to understand its mechanism and to know what consequences could have in vivo. These findings suggest that azaspiracids might have chronic cardiotoxicity related to hERG channel trafficking and they should not be overlooked when evaluating the threat to human health. PMID:25286396

  18. Unsuccessful Detection of Plant MicroRNAs in Beer, Extra Virgin Olive Oil and Human Plasma After an Acute Ingestion of Extra Virgin Olive Oil.

    PubMed

    Micó, Victor; Martín, Roberto; Lasunción, Miguel A; Ordovás, Jose M; Daimiel, Lidia

    2016-03-01

    The recent description of the presence of exogenous plant microRNAs from rice in human plasma had profound implications for the interpretation of microRNAs function in human health. If validated, these results suggest that food should not be considered only as a macronutrient and micronutrient supplier but it could also be a way of genomic interchange between kingdoms. Subsequently, several studies have tried to replicate these results in rice and other plant foods and most of them have failed to find plant microRNAs in human plasma. In this scenario, we aimed to detect plant microRNAs in beer and extra virgin olive oil (EVOO)--two plant-derived liquid products frequently consumed in Spain--as well as in human plasma after an acute ingestion of EVOO. Our hypothesis was that microRNAs present in beer and EVOO raw material could survive manufacturing processes, be part of these liquid products, be absorbed by human gut and circulate in human plasma. To test this hypothesis, we first optimized the microRNA extraction protocol to extract microRNAs from beer and EVOO, and then tried to detect microRNAs in those samples and in plasma samples of healthy volunteers after an acute ingestion of EVOO.

  19. Low abundance of sweat duct Cl− channel CFTR in both healthy and cystic fibrosis athletes with exceptionally salty sweat during exercise

    PubMed Central

    Haack, Karla K. V.; Pollack, Brian P.; Millard-Stafford, Mindy; McCarty, Nael A.

    2011-01-01

    To understand potential mechanisms explaining interindividual variability observed in human sweat sodium concentration ([Na+]), we investigated the relationship among [Na+] of thermoregulatory sweat, plasma membrane expression of Na+ and Cl− transport proteins in biopsied human eccrine sweat ducts, and basal levels of vasopressin (AVP) and aldosterone. Lower ductal luminal membrane expression of the Cl− channel cystic fibrosis transmembrane conductance regulator (CFTR) was observed in immunofluorescent staining of sweat glands from healthy young adults identified as exceptionally “salty sweaters” (SS) (n = 6, P < 0.05) and from patients with cystic fibrosis (CF) (n = 6, P < 0.005) compared with ducts from healthy young adults with “typical” sweat [Na+] (control, n = 6). Genetic testing of healthy subjects did not reveal any heterozygotes (“carriers”) for any of the 39 most common disease-causing CFTR mutations in the United States. SS had higher baseline plasma [AVP] compared with control (P = 0.029). Immunostaining to investigate a potential relationship between higher plasma [AVP] (and sweat [Na+]) and ductal membrane aquaporin-5 revealed for all groups a relatively sparse and location-dependent ductal expression of the water channel with localization primarily to the secretory coil. Availability of CFTR for NaCl transport across the ductal membrane appears related to the significant physiological variability observed in sweat salt concentration in apparently healthy humans. At present, a heritable link between healthy salty sweaters and the most prevalent disease-causing CFTR mutations cannot be established. PMID:21228336

  20. In vitro control of human bone marrow stromal cells for bone tissue engineering.

    PubMed

    Anselme, Karine; Broux, Odile; Noel, Benoit; Bouxin, Bertrand; Bascoulergue, Gerard; Dudermel, Anne-France; Bianchi, Fabien; Jeanfils, Joseph; Hardouin, Pierre

    2002-12-01

    For the clinical application of cultured human mesenchymal stem cells (MSCs), cells must have minimal contact with fetal calf serum (FCS) because it might be a potential vector for contamination by adventitious agents. The use of human plasma and serum for clinical applications also continues to give rise to considerable concerns with respect to the transmission of known and unknown human infectious agents. With the objective of clinical applications of cultured human MSCs, we tested the ability of autologous plasma, AB human serum, FCS, and artificial serum substitutes containing animal-derived proteins (Ultroser G) or vegetable-derived proteins (Prolifix S6) to permit their growth and differentiation in vitro. To conserve as much autologous plasma as possible, we attempted to mix it at decreasing concentrations with the serum substitute containing vegetable-derived mitogenic factors. Under control conditions, by day 10 all the fibroblast colony-forming units (CFU-Fs) were alkaline phosphatase (ALP) positive. However, their number and size were highly variable among donors. Better CFU-F formation was obtained with Ultroser G, and with human AB serum and autologous plasma mixed at, respectively, 5 and 1% with Prolifix S6. The effects of these mixtures on CFU-F formation demonstrate synergy, with the human serum or plasma supplying the factors that favor differentiation of MSCs while Prolifix S6 supplies the mitogenic factors. Finally, we demonstrated the possibility of controlling human MSC growth and differentiation in vitro. Notably, by means of a minimal quantity of human serum or human plasma mixed with a new serum substitute containing vegetable-derived proteins, we displayed growth and differentiation of human MSCs comparable to that obtained with FCS or serum substitutes containing animal-derived proteins. These results will have crucial significance for future applications of cultured human MSCs in bone tissue engineering.

  1. Haplotypes in the APOA1-C3-A4-A5 gene cluster affect plasma lipids in both humans and baboons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Qian-fei; Liu, Xin; O'Connell, Jeff

    2003-09-15

    Genetic studies in non-human primates serve as a potential strategy for identifying genomic intervals where polymorphisms impact upon human disease-related phenotypes. It remains unclear, however, whether independently arising polymorphisms in orthologous regions of non-human primates leads to similar variation in a quantitative trait found in both species. To explore this paradigm, we studied a baboon apolipoprotein gene cluster (APOA1/C3/A4/A5) for which the human gene orthologs have well established roles in influencing plasma HDL-cholesterol and triglyceride concentrations. Our extensive polymorphism analysis of this 68 kb gene cluster in 96 pedigreed baboons identified several haplotype blocks each with limited diversity, consistent withmore » haplotype findings in humans. To determine whether baboons, like humans, also have particular haplotypes associated with lipid phenotypes, we genotyped 634 well characterized baboons using 16 haplotype tagging SNPs. Genetic analysis of single SNPs, as well as haplotypes, revealed an association of APOA5 and APOC3 variants with HDL cholesterol and triglyceride concentrations, respectively. Thus, independent variation in orthologous genomic intervals does associate with similar quantitative lipid traits in both species, supporting the possibility of uncovering human QTL genes in a highly controlled non-human primate model.« less

  2. Oral hypertonic saline causes transient fall of vasopressin in humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seckl, J.R.; Williams, D.M.; Lightman, S.L.

    1986-08-01

    After dehydration, oral rehydration causes a fall in plasma arginine vasopressin (AVP) that precedes changes in plasma osmolality. To investigate further the stimulus for this effect, its specificity, and association with thirst, six volunteers were deprived of water for 24 h and given a salt load on two separate occasions. On each study day they then drank rapidly 10 ml/kg of either tap water or hypertonic saline (360 mosmol/kg). There was a significant fall in plasma AVP from 2.0 +/- 0.3 to 1.2 +/- 0.4 pmol/l 5 min after drinking water and from 1.8 +/- 0.3 to 0.9 +/- 0.2more » pmol/l after hypertonic saline. Plasma osmolality fell 30-60 min after water and was unchanged after saline. Plasma renin activity, oxytocin, and total protein all remained unchanged. All subjects reported diminished thirst after hypertonic saline. Gargling with water reduced thirst but did not affect plasma AVP. There appears to be a drinking-mediated neuroendocrine reflex that decreases plasma AVP irrespective of the osmolality of the liquid consumed. The sensation of thirst did not correlate with plasma osmolality and was not always related to plasma AVP concentration. AVP was measured by radioimmunoassay.« less

  3. PCB 28 metabolites elimination kinetics in human plasma on a real case scenario: Study of hydroxylated polychlorinated biphenyl (OH-PCB) metabolites of PCB 28 in a highly exposed German Cohort.

    PubMed

    Quinete, Natalia; Esser, André; Kraus, Thomas; Schettgen, Thomas

    2017-07-05

    Polychlorinated biphenyls (PCBs) are suspected of carcinogenic, neurotoxic and immunotoxic effects in animals and humans. Although background levels of PCBs have been slowly decreased after their ban, they are still among the most persistent and ubiquitous pollutants in the environment, remaining the subject of great concern. PCB 28 is a trichlorinated PCB found in high concentrations not only in human plasma but also in indoor air in Europe, yet little is known about its metabolic pathway and potential metabolites in humans. The present study aims to elucidate the kinetics of metabolite formation and elimination by analyzing four hydroxylated PCBs (OH-PCBs) in human plasma as potential metabolites of the PCB 28 congener. For this purpose, the study was conducted in plasma samples of highly PCB-exposed individuals (N=268), collected from 2010 to 2014 as a representation of a real case scenario with longitudinal data. OH-PCBs have been predicted, synthesized in the course of this study and further identified and quantitated in human plasma. This is the first time that previously unknown PCB 28 metabolites have been measured in human plasma and half-lives have been estimated for PCB metabolites, which could then provide further understanding in the toxicological consequences of exposure to PCBs in humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. [The possibility of using PlasmaDeepDive™ MRM panel in clinical diagnostics].

    PubMed

    Miroshnichenko, Iu V; Petushkova, N A; Moskaleva, N E; Teryaeva, N B; Zgoda, V G; Ilgisonis, E V; Belyaev, A Yu

    2015-01-01

    Concentrations of 46 proteins have been determined in human blood plasma using PlasmaDeepDive™ MRM Panel ("Biognosys AG", Switzerland). 18 of them were included into the group of proteins with higher concentrations, also identified by the shotgun proteomic analysis. Based on literature data it is concluded that the PlasmaDeepDive™ MRM Panel is applicable for studies of human plasma samples for potential biomarkers of various nervous system disorders.

  5. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography–Tandem Mass Spectrometry

    PubMed Central

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-01-01

    Abstract A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography–tandem mass spectrometry (LC–MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r2 > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. PMID:26538544

  6. Significant increase in salivary substance p level after a single oral dose of cevimeline in humans.

    PubMed

    Suzuki, Yosuke; Itoh, Hiroki; Amada, Kohei; Yamamura, Ryota; Sato, Yuhki; Takeyama, Masaharu

    2013-01-01

    Cevimeline is a novel muscarinic acetylcholine receptor agonist currently being developed as a therapeutic agent for xerostomia. We examined the effects of cevimeline on salivary and plasma levels of substance-P- (SP-), calcitonin-gene-related-peptide- (CGRP-), and vasoactive-intestinal-polypeptide- (VIP-) like immunoreactive substances (ISs) in humans. An open-labeled crossover study was conducted on seven healthy volunteers. Saliva volume was measured, and saliva and venous blood samples were collected before and 30-240 min after a single oral dose of cevimeline or placebo. Salivary and plasma levels of SP-, CGRP-, and VIP-IS were measured using a highly sensitive enzyme immunoassay. A single oral dose of cevimeline resulted in significant increases in salivary but not plasma SP-IS level compared to placebo. Cevimeline administration did not alter the salivary or plasma levels of CGRP-IS or VIP-IS compared to placebo. Significant increases in salivary volume were observed after cevimeline administration compared to placebo. A significant correlation was observed between the total release of SP-IS and that of salivary volume. These findings suggest an association of SP with the enhancement of salivary secretion by cevimeline.

  7. Significant Increase in Salivary Substance P Level after a Single Oral Dose of Cevimeline in Humans

    PubMed Central

    Suzuki, Yosuke; Itoh, Hiroki; Amada, Kohei; Yamamura, Ryota; Sato, Yuhki; Takeyama, Masaharu

    2013-01-01

    Cevimeline is a novel muscarinic acetylcholine receptor agonist currently being developed as a therapeutic agent for xerostomia. We examined the effects of cevimeline on salivary and plasma levels of substance-P- (SP-), calcitonin-gene-related-peptide- (CGRP-), and vasoactive-intestinal-polypeptide- (VIP-) like immunoreactive substances (ISs) in humans. An open-labeled crossover study was conducted on seven healthy volunteers. Saliva volume was measured, and saliva and venous blood samples were collected before and 30–240 min after a single oral dose of cevimeline or placebo. Salivary and plasma levels of SP-, CGRP-, and VIP-IS were measured using a highly sensitive enzyme immunoassay. A single oral dose of cevimeline resulted in significant increases in salivary but not plasma SP-IS level compared to placebo. Cevimeline administration did not alter the salivary or plasma levels of CGRP-IS or VIP-IS compared to placebo. Significant increases in salivary volume were observed after cevimeline administration compared to placebo. A significant correlation was observed between the total release of SP-IS and that of salivary volume. These findings suggest an association of SP with the enhancement of salivary secretion by cevimeline. PMID:23589717

  8. Production of Cloned Miniature Pigs Expressing High Levels of Human Apolipoprotein(a) in Plasma.

    PubMed

    Ozawa, Masayuki; Himaki, Takehiro; Ookutsu, Shoji; Mizobe, Yamato; Ogawa, Junki; Miyoshi, Kazuchika; Yabuki, Akira; Fan, Jianglin; Yoshida, Mitsutoshi

    2015-01-01

    High lipoprotein(a) [Lp(a)] levels are a major risk factor for the development of atherosclerosis. However, because apolipoprotein(a) [apo(a)], the unique component of Lp(a), is found only in primates and humans, the study of human Lp(a) has been hampered due to the lack of appropriate animal models. Using somatic cell nuclear transfer (SCNT) techniques, we produced transgenic miniature pigs expressing human apo(a) in the plasma. First, we placed the hemagglutinin (HA)-tagged cDNA of human apo(a) under the control of the β-actin promoter and cytomegalovirus enhancer, and then introduced this construct into kidney epithelial cells. Immunostaining of cells with anti-HA antibody allowed identification of cells stably expressing apo(a); one of the positive clones was used to provide donor cells for SCNT, yielding blastocysts that expressed apo(a). Immunohistochemical analysis of tissue sections and RT-PCR analysis of total RNA from organs of cloned piglet revealed that apo(a) is expressed in various tissues/organs including heart, liver, kidney, and intestine. More importantly, a transgenic line exhibited a high level (>400 mg/dL) of Lp(a) in plasma, and the transgenic apo(a) gene was transmitted to the offspring. Thus, we generated a human apo(a)-transgenic miniature pig that can be used as a model system to study advanced atherosclerosis related to human disease. The anatomical and physiological similarities between the swine and human cardiovascular systems will make this pig model a valuable source of information on the role of apo(a) in the formation of atherosclerosis, as well as the mechanisms underlying vascular health and disease.

  9. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  10. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  11. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  12. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  13. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  14. Development of a microplate coagulation assay for Factor V in human plasma

    PubMed Central

    2011-01-01

    Background Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. Methods The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. Results The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. Conclusions The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement of the functional coagulation activity of FV in human plasma. PMID:21711555

  15. Effect of the long-term regular intake of virgin olive oil on the phenolic metabolites in human fasting plasma.

    PubMed

    Valls, Rosa-Maria; Soler, Aranzazu; Girona, Josefa; Heras, Mercedes; Romero, Maria-Paz; Covas, Maria-Isabel; Solà, Rosa; Masana, Lluis; Motilva, Maria-Jose

    2010-09-21

    The effect of repeated consumption of virgin olive oil on endogenous phenolic metabolites of fasting plasma is unknown. For this reason, we hypothesized that regular long-term virgin olive oil intake could have an indirect protection effect on the endogenous phenols. Thus, the aim of the study was to determine the phenolic profile of human plasma in a fasting state of long-term regular virgin olive oil consumers, using the fasting plasma of non-consumers as a natural control. Forty participants living in the area of Reus (Catalonia, Spain) were selected, 20 life-long regular consumers of virgin olive oil and a natural control of 20 non-consumers, the latter being Rumanians who dislike the taste of olive oil. The diet was obtained from 3-day food records. The results showed similar phenolic composition of fasting plasmas of the two volunteer groups. Of special interest is that more of the compounds quantified showed higher concentration in fasting plasma from habitual virgin olive oil consumers. The compounds were semi-quantified using caffeic acid as the calibration standard. The quantification of fasting consumer's plasma showed higher concentration of a hydroxyflavanone type compound (2.90+/-0.04 microM vs 1.5+/-0.04 microM) and a catecholamine derivative (0.70+/-0.03 microM vs 0.56+/-0.03 microM) than the plasma of non-consumers (P<0.05). The results suggest an indirect protective mechanism of long-term regular virgin olive oil consumption related to the protection of the endogenous antioxidant system. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Evaluation of tranexamic acid and ε-aminocaproic acid concentrations required to inhibit fibrinolysis in plasma of dogs and humans.

    PubMed

    Fletcher, Daniel J; Blackstock, Kelly J; Epstein, Kira; Brainard, Benjamin M

    2014-08-01

    To determine minimum plasma concentrations of the antifibrinolytic agents tranexamic acid (TEA) and ε-aminocaproic acid (EACA) needed to completely inhibit fibrinolysis in canine and human plasma after induction of hyperfibrinolysis. Pooled citrated plasma from 7 dogs and commercial pooled citrated human plasma. Concentrations of EACA from 0 μg/mL to 500 μg/mL and of TEA from 0 μg/mL to 160 μg/mL were added to pooled citrated canine and human plasma. Hyperfibrinolysis was induced with 1,000 units of tissue plasminogen activator/mL, and kaolin-activated thromboelastography was performed in duplicate. The minimum concentrations required to completely inhibit fibrinolysis 30 minutes after maximum amplitude of the thromboelastography tracing occurred were determined. Minimum plasma concentrations necessary for complete inhibition of fibrinolysis by EACA and TEA in pooled canine plasma were estimated as 511.7 μg/mL (95% confidence interval [CI], 433.2 to 590.3 μg/mL) and 144.7 μg/mL (95% CI, 125.2 to 164.2 μg/mL), respectively. Concentrations of EACA and TEA necessary for complete inhibition of fibrinolysis in pooled human plasma were estimated as 122.0 μg/mL (95% CI, 106.2 to 137.8 μg/mL) and 14.7 μg/mL (95% CI, 13.7 to 15.6 μg/mL), respectively. Results supported the concept that dogs are hyperfibrinolytic, compared with humans. Higher doses of EACA and TEA may be required to fully inhibit fibrinolysis in dogs.

  17. Procoagulant snake venoms have differential effects in animal plasmas: Implications for antivenom testing in animal models.

    PubMed

    Maduwage, Kalana P; Scorgie, Fiona E; Lincz, Lisa F; O'Leary, Margaret A; Isbister, Geoffrey K

    2016-01-01

    Animal models are used to test toxic effects of snake venoms/toxins and the antivenom required to neutralise them. However, venoms that cause clinically relevant coagulopathy in humans may have differential effects in animals. We aimed to investigate the effect of different procoagulant snake venoms on various animal plasmas. Prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen and D-dimer levels were measured in seven animal plasmas (human, rabbit, cat, guinea pig, pig, cow and rat). In vitro clotting times were then used to calculate the effective concentration (EC50) in each plasma for four snake venoms with different procoagulant toxins: Pseudonaja textilis, Daboia russelli, Echis carinatus and Calloselasma rhodostoma. Compared to human, PT and aPTT were similar for rat, rabbit and pig, but double for cat and cow, while guinea pig had similar aPTT but double PT. Fibrinogen and D-dimer levels were similar for all species. Human and rabbit plasmas had the lowest EC50 for P. textilis (0.1 and 0.4 μg/ml), D. russelli (0.4 and 0.1 μg/ml), E. carinatus (0.6 and 0.1 μg/ml) venoms respectively, while cat plasma had the lowest EC50 for C. rhodostoma (11 μg/ml) venom. Cow, rat, pig and guinea pig plasmas were highly resistant to all four venoms with EC50 10-fold that of human. Different animal plasmas have varying susceptibility to procoagulant venoms, and excepting rabbits, animal models are not appropriate to test procoagulant activity. In vitro assays on human plasma should instead be adopted for this purpose. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Inactivation of Zika virus by solvent/detergent treatment of human plasma and other plasma-derived products and pasteurization of human serum albumin.

    PubMed

    Kühnel, Denis; Müller, Sebastian; Pichotta, Alexander; Radomski, Kai Uwe; Volk, Andreas; Schmidt, Torben

    2017-03-01

    In 2016 the World Health Organization declared the mosquito-borne Zika virus (ZIKV) a "public health emergency of international concern." ZIKV is a blood-borne pathogen, which therefore causes concerns regarding the safety of human plasma-derived products due to potential contamination of the blood supply. This study investigated the effectiveness of viral inactivation steps used during the routine manufacturing of various plasma-derived products to reduce ZIKV infectivity. Human plasma and intermediates from the production of various plasma-derived products were spiked with ZIKV and subjected to virus inactivation using the identical techniques (either solvent/detergent [S/D] treatment or pasteurization) and conditions used for the actual production of the respective products. Samples were taken and the viral loads measured before and after inactivation. After S/D treatment of spiked intermediates of the plasma-derived products Octaplas(LG), Octagam, and Octanate, the viral loads were below the limit of detection in all cases. The mean log reduction factor (LRF) was at least 6.78 log for Octaplas(LG), at least 7.00 log for Octagam, and at least 6.18 log for Octanate after 60, 240, and 480 minutes of S/D treatment, respectively. For 25% human serum albumin (HSA), the mean LRF for ZIKV was at least 7.48 log after pasteurization at 60°C for 120 minutes. These results demonstrate that the commonly used virus inactivation processes utilized during the production of human plasma and plasma-derived products, namely, S/D treatment or pasteurization, are effective for inactivation of ZIKV. © 2016 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  19. Differential Responses of Plasma Adropin Concentrations To Dietary Glucose or Fructose Consumption In Humans.

    PubMed

    Butler, Andrew A; St-Onge, Marie-Pierre; Siebert, Emily A; Medici, Valentina; Stanhope, Kimber L; Havel, Peter J

    2015-10-05

    Adropin is a peptide hormone encoded by the Energy Homeostasis Associated (ENHO) gene whose physiological role in humans remains incompletely defined. Here we investigated the impact of dietary interventions that affect systemic glucose and lipid metabolism on plasma adropin concentrations in humans. Consumption of glucose or fructose as 25% of daily energy requirements (E) differentially affected plasma adropin concentrations (P < 0.005) irrespective of duration, sex or age. Glucose consumption reduced plasma adropin from 3.55 ± 0.26 to 3.28 ± 0.23 ng/ml (N = 42). Fructose consumption increased plasma adropin from 3.63 ± 0.29 to 3.93 ± 0.34 ng/ml (N = 45). Consumption of high fructose corn syrup (HFCS) as 25% E had no effect (3.43 ± 0.32 versus 3.39 ± 0.24 ng/ml, N = 26). Overall, the effect of glucose, HFCS and fructose on circulating adropin concentrations were similar to those observed on postprandial plasma triglyceride concentrations. Furthermore, increases in plasma adropin levels with fructose intake were most robust in individuals exhibiting hypertriglyceridemia. Individuals with low plasma adropin concentrations also exhibited rapid increases in plasma levels following consumption of breakfasts supplemented with lipids. These are the first results linking plasma adropin levels with dietary sugar intake in humans, with the impact of fructose consumption linked to systemic triglyceride metabolism. In addition, dietary fat intake may also increase circulating adropin concentrations.

  20. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium.

    PubMed

    Nakao, Ryuji; Halldin, Christer

    2013-07-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for (11)C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. The human plasma-metabolome: Reference values in 800 French healthy volunteers; impact of cholesterol, gender and age

    PubMed Central

    Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe

    2017-01-01

    Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the “normal” metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the “normal” metabolome and its main sources of variation. PMID:28278231

  2. The human plasma-metabolome: Reference values in 800 French healthy volunteers; impact of cholesterol, gender and age.

    PubMed

    Trabado, Séverine; Al-Salameh, Abdallah; Croixmarie, Vincent; Masson, Perrine; Corruble, Emmanuelle; Fève, Bruno; Colle, Romain; Ripoll, Laurent; Walther, Bernard; Boursier-Neyret, Claire; Werner, Erwan; Becquemont, Laurent; Chanson, Philippe

    2017-01-01

    Metabolomic approaches are increasingly used to identify new disease biomarkers, yet normal values of many plasma metabolites remain poorly defined. The aim of this study was to define the "normal" metabolome in healthy volunteers. We included 800 French volunteers aged between 18 and 86, equally distributed according to sex, free of any medication and considered healthy on the basis of their medical history, clinical examination and standard laboratory tests. We quantified 185 plasma metabolites, including amino acids, biogenic amines, acylcarnitines, phosphatidylcholines, sphingomyelins and hexose, using tandem mass spectrometry with the Biocrates AbsoluteIDQ p180 kit. Principal components analysis was applied to identify the main factors responsible for metabolome variability and orthogonal projection to latent structures analysis was employed to confirm the observed patterns and identify pattern-related metabolites. We established a plasma metabolite reference dataset for 144/185 metabolites. Total blood cholesterol, gender and age were identified as the principal factors explaining metabolome variability. High total blood cholesterol levels were associated with higher plasma sphingomyelins and phosphatidylcholines concentrations. Compared to women, men had higher concentrations of creatinine, branched-chain amino acids and lysophosphatidylcholines, and lower concentrations of sphingomyelins and phosphatidylcholines. Elderly healthy subjects had higher sphingomyelins and phosphatidylcholines plasma levels than young subjects. We established reference human metabolome values in a large and well-defined population of French healthy volunteers. This study provides an essential baseline for defining the "normal" metabolome and its main sources of variation.

  3. Toward the automated analysis of plasma physics problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mynick, H.E.

    1989-04-01

    A program (CALC) is described, which carries out nontrivial plasma physics calculations, in a manner intended to emulate the approach of a human theorist. This includes the initial process of gathering the relevant equations from a plasma knowledge base, and then determining how to solve them. Solution of the sets of equations governing physics problems, which in general have a nonuniform,irregular structure, not amenable to solution by standardized algorithmic procedures, is facilitated by an analysis of the structure of the equations and the relations among them. This often permits decompositions of the full problem into subproblems, and other simplifications inmore » form, which renders the resultant subsystems soluble by more standardized tools. CALC's operation is illustrated by a detailed description of its treatment of a sample plasma calculation. 5 refs., 3 figs.« less

  4. Characterization and localization of cysteine-rich secretory protein 3 (CRISP-3) in the human male reproductive tract.

    PubMed

    Udby, Lene; Bjartell, Anders; Malm, Johan; Egesten, Arne; Lundwall, Ake; Cowland, Jack B; Borregaard, Niels; Kjeldsen, Lars

    2005-01-01

    Mammalian members of the cysteine-rich secretory protein (CRISP) family are expressed predominantly in the male reproductive tract and are implicated in the process of reproduction from spermiogenesis, posttesticular sperm maturation, and capacitation to oocyte-sperm fusion, and possibly also penetration of the zona pellucida. Rodents express only 2 CRISPs (CRISP-1 and CRISP-2) in their male reproductive system, whereas humans and horses express an additional third member named CRISP-3. We have previously demonstrated that this protein is present in human seminal plasma as well as in other exocrine secretions, in blood plasma, and in neutrophilic granulocytes. To characterize the protein in seminal plasma and localize the production of CRISP-3 in the human male reproductive tract, we performed immunoblotting and enzyme-linked immunosorbent assay measurements of seminal plasma and immunohistochemistry and in situ hybridization of tissue specimens. We were able to show that human CRISP-3 is a quantitatively minor seminal plasma protein not associated with prostasomes. Furthermore, CRISP-3 expression was found in the secretory epithelium throughout the male genital tract, with particularly high expression in the cauda epididymis and ampulla vas deferens. Examination of seminal plasma from vasectomized males indicates that organs downstream of the epididymis are probably the major sources of seminal plasma CRISP-3.

  5. A cobalt oxyhydroxide-modified upconversion nanosystem for sensitive fluorescence sensing of ascorbic acid in human plasma

    NASA Astrophysics Data System (ADS)

    Cen, Yao; Tang, Jun; Kong, Xiang-Juan; Wu, Shuang; Yuan, Jing; Yu, Ru-Qin; Chu, Xia

    2015-08-01

    Ascorbic acid (AA), a potent antioxidant readily scavenging reactive species, is a crucial micronutrient involved in many biochemical processes. Here, we have developed a cobalt oxyhydroxide (CoOOH)-modified upconversion nanosystem for fluorescence sensing of AA activity in human plasma. The nanosystem consists of upconversion nanoparticles (UCNPs) NaYF4:30% Yb,0.5% Tm@NaYF4, which serve as energy donors, and CoOOH nanoflakes formed on the surface of UCNPs, which act as efficient energy acceptors. The fluorescence resonance energy transfer (FRET) process from the UCNPs to the absorbance of the CoOOH nanoflakes occurs in the nanosystem. The AA-mediated specific redox reaction reduces CoOOH into Co2+, leading to the inhibition of FRET, and resulting in the recovery of upconversion emission spectra. On the basis of these features, the nanosystem can be used for sensing AA activity with sensitivity and selectivity. Moreover, due to the minimizing background interference provided by UCNPs, the nanosystem has been applied to monitoring AA levels in human plasma sample with satisfactory results. The proposed approach may potentially provide an analytical platform for research and clinical diagnosis of AA related diseases.Ascorbic acid (AA), a potent antioxidant readily scavenging reactive species, is a crucial micronutrient involved in many biochemical processes. Here, we have developed a cobalt oxyhydroxide (CoOOH)-modified upconversion nanosystem for fluorescence sensing of AA activity in human plasma. The nanosystem consists of upconversion nanoparticles (UCNPs) NaYF4:30% Yb,0.5% Tm@NaYF4, which serve as energy donors, and CoOOH nanoflakes formed on the surface of UCNPs, which act as efficient energy acceptors. The fluorescence resonance energy transfer (FRET) process from the UCNPs to the absorbance of the CoOOH nanoflakes occurs in the nanosystem. The AA-mediated specific redox reaction reduces CoOOH into Co2+, leading to the inhibition of FRET, and resulting in the recovery of upconversion emission spectra. On the basis of these features, the nanosystem can be used for sensing AA activity with sensitivity and selectivity. Moreover, due to the minimizing background interference provided by UCNPs, the nanosystem has been applied to monitoring AA levels in human plasma sample with satisfactory results. The proposed approach may potentially provide an analytical platform for research and clinical diagnosis of AA related diseases. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03588k

  6. Advanced glycation end products are elevated in cystic fibrosis-related diabetes and correlate with worse lung function.

    PubMed

    Hunt, William R; Helfman, Beth R; McCarty, Nael A; Hansen, Jason M

    2016-09-01

    The onset of cystic fibrosis-related diabetes (CFRD) exacerbates lung function decline and increases mortality. One pathway that may worsen the lung dysfunction associated with CFRD is that of the receptor for advanced glycation end products (RAGE) and its ligands. Human plasma was obtained from age-matched healthy, CF and CFRD patients. Plasma RAGE ligands (i.e. advanced glycation end products, S100A12, and high-mobility group protein B1) and soluble RAGE (sRAGE) levels were measured. CFRD patients had elevated plasma levels of AGEs and S100A12. Soluble RAGE, a RAGE ligand decoy receptor, was not significantly different between groups. Plasma AGE levels and S100A12 levels had significantly negative correlations with FEV1. AGEs are significantly elevated in CFRD and correlate negatively with FEV1. CFRD patients did not have significant increases in the decoy sRAGE, suggesting there may be heightened binding and activation of RAGE in CFRD exacerbating activation of proinflammatory pathways. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  7. Obesity-related metabolic dysfunction in dogs: a comparison with human metabolic syndrome.

    PubMed

    Tvarijonaviciute, Asta; Ceron, Jose J; Holden, Shelley L; Cuthbertson, Daniel J; Biourge, Vincent; Morris, Penelope J; German, Alexander J

    2012-08-28

    Recently, metabolic syndrome (MS) has gained attention in human metabolic medicine given its associations with development of type 2 diabetes mellitus and cardiovascular disease. Canine obesity is associated with the development of insulin resistance, dyslipidaemia, and mild hypertension, but the authors are not aware of any existing studies examining the existence or prevalence of MS in obese dogs.Thirty-five obese dogs were assessed before and after weight loss (median percentage loss 29%, range 10-44%). The diagnostic criteria of the International Diabetes Federation were modified in order to define canine obesity-related metabolic dysfunction (ORMD), which included a measure of adiposity (using a 9-point body condition score [BCS]), systolic blood pressure, fasting plasma cholesterol, plasma triglyceride, and fasting plasma glucose. By way of comparison, total body fat mass was measured by dual-energy X-ray absorptiometry, whilst total adiponectin, fasting insulin, and high-sensitivity C-reactive protein (hsCRP) were measured using validated assays. Systolic blood pressure (P = 0.008), cholesterol (P = 0.003), triglyceride (P = 0.018), and fasting insulin (P < 0.001) all decreased after weight loss, whilst plasma total adiponectin increased (P = 0.001). However, hsCRP did not change with weight loss. Prior to weight loss, 7 dogs were defined as having ORMD, and there was no difference in total fat mass between these dogs and those who did not meet the criteria for ORMD. However, plasma adiponectin concentration was less (P = 0.031), and plasma insulin concentration was greater (P = 0.030) in ORMD dogs. In this study, approximately 20% of obese dogs suffer from ORMD, and this is characterized by hypoadiponectinaemia and hyperinsulinaemia. These studies can form the basis of further investigations to determine path genetic mechanisms and the health significance for dogs, in terms of disease associations and outcomes of weight loss.

  8. Early second trimester maternal plasma choline and betaine are related to measures of early cognitive development in term infants.

    PubMed

    Wu, Brian T F; Dyer, Roger A; King, D Janette; Richardson, Kelly J; Innis, Sheila M

    2012-01-01

    The importance of maternal dietary choline for fetal neural development and later cognitive function has been well-documented in experimental studies. Although choline is an essential dietary nutrient for humans, evidence that low maternal choline in pregnancy impacts neurodevelopment in human infants is lacking. We determined potential associations between maternal plasma free choline and its metabolites betaine and dimethylglycine in pregnancy and infant neurodevelopment at 18 months of age. This was a prospective study of healthy pregnant women and their full-term, single birth infants. Maternal blood was collected at 16 and 36 weeks of gestation and infant neurodevelopment was assessed at 18 months of age for 154 mother-infant pairs. Maternal plasma choline, betaine, dimethylglycine, methionine, homocysteine, cysteine, total B12, holotranscobalamin and folate were quantified. Infant neurodevelopment was evaluated using the Bayley Scales of Infant Development-III. Multivariate regression, adjusting for covariates that impact development, was used to determine the associations between maternal plasma choline, betaine and dimethylglycine and infant neurodevelopment. The maternal plasma free choline at 16 and 36 weeks gestation was median (interquartile range) 6.70 (5.78-8.03) and 9.40 (8.10-11.3) µmol/L, respectively. Estimated choline intakes were (mean ± SD) 383 ± 98.6 mg/day, and lower than the recommended 450 mg/day. Betaine intakes were 142 ± 70.2 mg/day. Significant positive associations were found between infant cognitive test scores and maternal plasma free choline (B=6.054, SE=2.283, p=0.009) and betaine (B=7.350, SE=1.933, p=0.0002) at 16 weeks of gestation. Maternal folate, total B12, or holotranscobalamin were not related to infant development. We show that choline status in the first half of pregnancy is associated with cognitive development among healthy term gestation infants. More work is needed on the potential limitation of choline or betaine in the diets of pregnant women.

  9. Obesity-related metabolic dysfunction in dogs: a comparison with human metabolic syndrome

    PubMed Central

    2012-01-01

    Background Recently, metabolic syndrome (MS) has gained attention in human metabolic medicine given its associations with development of type 2 diabetes mellitus and cardiovascular disease. Canine obesity is associated with the development of insulin resistance, dyslipidaemia, and mild hypertension, but the authors are not aware of any existing studies examining the existence or prevalence of MS in obese dogs. Thirty-five obese dogs were assessed before and after weight loss (median percentage loss 29%, range 10-44%). The diagnostic criteria of the International Diabetes Federation were modified in order to define canine obesity-related metabolic dysfunction (ORMD), which included a measure of adiposity (using a 9-point body condition score [BCS]), systolic blood pressure, fasting plasma cholesterol, plasma triglyceride, and fasting plasma glucose. By way of comparison, total body fat mass was measured by dual-energy X-ray absorptiometry, whilst total adiponectin, fasting insulin, and high-sensitivity C-reactive protein (hsCRP) were measured using validated assays. Results Systolic blood pressure (P = 0.008), cholesterol (P = 0.003), triglyceride (P = 0.018), and fasting insulin (P < 0.001) all decreased after weight loss, whilst plasma total adiponectin increased (P = 0.001). However, hsCRP did not change with weight loss. Prior to weight loss, 7 dogs were defined as having ORMD, and there was no difference in total fat mass between these dogs and those who did not meet the criteria for ORMD. However, plasma adiponectin concentration was less (P = 0.031), and plasma insulin concentration was greater (P = 0.030) in ORMD dogs. Conclusions In this study, approximately 20% of obese dogs suffer from ORMD, and this is characterized by hypoadiponectinaemia and hyperinsulinaemia. These studies can form the basis of further investigations to determine path genetic mechanisms and the health significance for dogs, in terms of disease associations and outcomes of weight loss. PMID:22929809

  10. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    PubMed Central

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-01-01

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400

  11. Development of an Advanced HPLC-MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma.

    PubMed

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-10-14

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC-MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC-DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  12. Hyperhomocysteinemia and protein damage in chronic renal failure and kidney transplant pediatric patients--Italian initiative on uremic hyperhomocysteinemia (IIUH).

    PubMed

    Perna, Alessandra F; Ingrosso, Diego; Molino, Daniela; Galletti, Patrizia; Montini, Giovanni; Zacchello, Graziella; Bellantuono, Rosa; Caringella, Angela; Fede, Carmelo; Chimenz, Roberto; De Santo, Natale G

    2003-01-01

    Plasma homocysteine, a new cardiovascular risk factor in both children and adults, is higher in chronic renal failure or kidney transplant patients. This alteration has been linked, in chronic renal failure, to plasma protein damage, represented by increased L-isoaspartyl residues. We measured plasma homocysteine levels and plasma protein damage in pediatric patients from four different Italian regions with conservatively treated renal failure; hemodialysis, continuous ambulatory peritoneal dialysis (CAPD), or transplants, to establish the presence of protein damage and the relative role of hyperhomocysteinemia. High performance liquid chromatography (HPLC) separation measured total plasma homocysteine levels, using precolumn derivatization with ammonium 7-fluorobenzo-2-oxa-1, 3-diazole-4-sulphonate (SBD-F). Plasma protein L-isoaspartyl residues were quantitated using human recombinant protein carboxyl methyl transferase (PCMT). In all patient groups, homocysteine levels were significantly higher with respect to the control (Control: 6.87 +/- 0.73 microM) conservatively treated, 14.19 +/- 1.73 microM; hemodialysis, 27.03 +/- 4.32 microM; CAPD, 22.38 +/- 3.73 microM; transplanted, 20.22 +/- 2.27 microM, p < 0.001 vs. control]. Plasma protein damage was significantly higher in conservatively treated, hemodialysis (HD) and CAPD patients, while in transplant patients it was no different from the control. We concluded that in pediatric patients of different Italian geographical origin, plasma homocysteine levels were significantly higher in all groups with respect to healthy children; therefore contributing to the elevated cardiovascular risk present in these patients. Plasma protein L-isoaspartyl content was higher in renal failure patients, but kidney transplant patients had normal levels, indicating that this kind of protein damage relates more to the toxic action of uremic retention solutes, than to plasma homocysteine levels.

  13. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  14. Mechanical and chemical characteristics of an autologous glue.

    PubMed

    De Somer, Filip; Delanghe, Joris; Somers, Pamela; Debrouwere, Maarten; Van Nooten, Guido

    2008-09-15

    The study evaluates the mechanical and chemical characteristics of autologous surgical glue made by mixing ultrafiltered plasma with glutaraldehyde (GTA). Human albumin 200 g/L mixed with different concentrations of GTA (25, 50, 75, or 100 g/L) was used as a single protein set-up for testing tensile strength, elasticity, and rate of crosslinking. Subsequently, ultrafiltered canine or human plasma to obtain autologous glue replaced human albumin. BioGlue, a surgical glue, and Tissucol Duo, a fibrin sealant, were used as controls. Tensile strength of human albumin 200 g/L mixed with 75 g/L GTA is 825 +/- 109 N versus 672 +/- 167 N for BioGlue. Ultrafiltered canine plasma showed a maximum tensile strength of 634 +/- 137 N when mixed with GTA 75 g/L. For human plasma, the maximum tensile strength of 436 +/- 69 N was reached after mixing with GTA 25 g/L. Autologous glue had a higher elasticity of 144 +/- 66 N versus 322 +/- 104 N for BioGlue at maximum load. Autologous glues for vascular repair can be easily prepared out of the patient's plasma. The optimal characteristics, compared to BioGlue, are obtained for ultrafiltered canine and human plasma by mixing with a GTA concentration of 50-75 g/L and 25-50 g/L, respectively. The autologous glue will exert less tensile strength than BioGlue but has a better compliance. In case where no plasma can obtained from the patient, mixing human albumin 200 g/L with GTA 75 g/L can be an alternative to BioGlue.

  15. Ultra-high performance liquid chromatographic determination of levofloxacin in human plasma and prostate tissue with use of experimental design optimization procedures.

    PubMed

    Szerkus, O; Jacyna, J; Wiczling, P; Gibas, A; Sieczkowski, M; Siluk, D; Matuszewski, M; Kaliszan, R; Markuszewski, M J

    2016-09-01

    Fluoroquinolones are considered as gold standard for the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. However, recent studies reported that fluoroquinolone- resistant bacterial strains are responsible for gradually increasing number of infections after transrectal prostate biopsy. In daily clinical practice, antibacterial efficacy is evaluated only in vitro, by measuring the reaction of bacteria with an antimicrobial agent in culture media (i.e. calculation of minimal inhibitory concentration). Such approach, however, has no relation to the treated tissue characteristics and might be highly misleading. Thus, the objective of this study was to develop, with the use of Design of Experiments approach, a reliable, specific and sensitive ultra-high performance liquid chromatography- diode array detection method for the quantitative analysis of levofloxacin in plasma and prostate tissue samples obtained from patients undergoing prostate biopsy. Moreover, correlation study between concentrations observed in plasma samples vs prostatic tissue samples was performed, resulting in better understanding, evaluation and optimization of the fluoroquinolone-based antimicrobial prophylaxis during transrectal ultrasound guided prostate biopsy. Box-Behnken design was employed to optimize chromatographic conditions of the isocratic elution program in order to obtain desirable retention time, peak symmetry and resolution of levofloxacine and ciprofloxacine (internal standard) peaks. Fractional Factorial design 2(4-1) with four center points was used for screening of significant factors affecting levofloxacin extraction from the prostatic tissue. Due to the limited number of tissue samples the prostatic sample preparation procedure was further optimized using Central Composite design. Design of Experiments approach was also utilized for evaluation of parameter robustness. The method was found linear over the range of 0.030-10μg/mL for human plasma and 0.300-30μg/g for human prostate tissue samples. The intra-day and inter-day variability for levofloxacine from both plasma and prostate samples were less than 10%, with accuracies between 93 and 108% of the nominal values. The limit of detection and the limit of quantification for human plasma were 0.01μg/mL and 0.03μg/mL, respectively. For the prostate tissue, the limit of detection and the limit of quantification were 0.1μg/g and 0.3μg/g, respectively. The average recoveries of levofloxacin were in the range from 99 to 106%. Also, the method fulfills requirements of robustness what was determined and proved by Design of Experiments. The developed method was successfully applied to examine prostate tissue and plasma samples from 140 hospitalized patients enrolled into the clinical study, 12h after oral administration of LVF at a dose of 500mg. The mean (±SD) LVF concentration in prostate was 6.22±3.52μg/g and in plasma 2.54±1.14μg/mL. Due to simplicity of the method and relative small amount of sample needed for the assay, the method can be applied in clinical practice for monitoring of LVF concentrations in plasma and prostate gland. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Proteolytic Processing of Angiotensin-I in Human Blood Plasma

    PubMed Central

    Hildebrand, Diana; Merkel, Philipp; Eggers, Lars Florian; Schlüter, Hartmut

    2013-01-01

    In mammalian species, except humans, N-terminal processing of the precursor peptide angiotensin I (ANG-1-10) into ANG-2-10 or ANG-3-10 was reported. Here we hypothesize that aminopeptidase-generated angiotensins bearing the same C-terminus as ANG-1-10 are also present in humans. We demonstrate the time dependent generation of ANG-2-10, ANG-3-10, ANG-4-10, ANG-5-10 and ANG-6-10 from the precursor ANG-1-10 by human plasma proteins. The endogenous presence of ANG-4-10, ANG-5-10 and ANG-6-10 in human plasma was confirmed by an immuno-fluorescence assay. Generation of ANG-2-10, ANG-3-10 and ANG-4-10 from ANG-1-10 by immobilized human plasma proteins was sensitive to the cysteine/serine protease inhibitor antipain. The metal ion chelator EDTA inhibited Ang-6-10-generation. Incubation of the substrates ANG-3-10, ANG-4-10 and ANG-5-10 with recombinant aminopeptidase N (APN) resulted in a successive N-terminal processing, finally releasing ANG-6-10 as a stable end product, demonstrating a high similarity concerning the processing pattern of the angiotensin peptides compared to the angiotensin generating activity in plasma. Recombinant ACE-1 hydrolyzed the peptides ANG-2-10, ANG-3-10, ANG-4-10 and ANG-5-10 into ANG-2-8, ANG-3-8, ANG-4-8 and ANG-5-8. Since ANG-2-10 was processed into ANG-2-8, ANG-4-8 and ANG-5-8 by plasma proteases the angiotensin peptides bearing the same C-terminus as ANG-1-10 likely have a precursor function in human plasma. Our results confirm the hypothesis of aminopeptidase mediated processing of ANG-1-10 in humans. We show the existence of an aminopeptidase mediated pathway in humans that bypasses the known ANG-1-8-carboxypeptidase pathway. This expands the knowledge about the known human renin angiotensin system, showing how efficiently the precursor ANG-1-10 is used by nature. PMID:23724017

  17. Determination of molindone enantiomers in human plasma by high-performance liquid chromatography-tandem mass spectrometry using macrocyclic antibiotic chiral stationary phases.

    PubMed

    Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C

    2008-05-30

    A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD

  18. Simultaneous determination of clofarabine and cytarabine in human plasma by LC-MS/MS.

    PubMed

    Büttner, Božena; Oertel, Reinhard; Schetelig, Johannes; Middeke, Jan Moritz; Bornhäuser, Martin; Seeling, Andreas; Knoth, Holger

    2016-06-05

    Combination of cytostatic agents is a basic principle in the treatment of cancer. For the treatment of acute myeloid leukemia (AML), purine analogs, like clofarabine and cytarabine act synergistically. Little is known, however, on their interaction in vivo. We developed a method for the simultaneous determination of clofarabine and cytarabine in human plasma. The substances were extracted from plasma samples by protein precipitation with acetonitrile. Cladribine was the internal standard (IS). The analytes were separated on Synergi HydroRP column (150mm×2.0mm, 4μm) and a triple-quadrupole mass spectrometry with an electrospray ionisation (ESI) source was applied for detection. The mobile phase consisted of acetonitrile, ammonium acetate 2mM and 0.5% formic acid in a gradient mode at a flow rate of 0.5ml/min. The injection volume was 10μl and the total run time was 6.0min. Retention times were 2.46min for clofarabine, 0.97min for cytarabine and 2.43min for the IS. Calibration ranges were 8-1000ng/ml for clofarabine and 20-2500ng/ml for cytarabine. The intra-day and inter-day precision was less than 15% and the relative standard deviation was all within ±15%. This new method allows a rapid and simple determination of both clofarabine and cytarabine in human plasma. It was applied to a pharmacokinetic investigation within a hematological trial in adult patients with AML. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Hemocompatibility of poly(vinylidene fluoride) membrane grafted with network-like and brush-like antifouling layer controlled via plasma-induced surface PEGylation.

    PubMed

    Chang, Yung; Shih, Yu-Ju; Ko, Chao-Yin; Jhong, Jheng-Fong; Liu, Ying-Ling; Wei, Ta-Chin

    2011-05-03

    In this work, the hemocompatibility of PEGylated poly(vinylidene fluoride) (PVDF) microporous membranes with varying grafting coverage and structures via plasma-induced surface PEGylation was studied. Network-like and brush-like PEGylated layers on PVDF membrane surfaces were achieved by low-pressure and atmospheric plasma treatment. The chemical composition, physical morphology, grafting structure, surface hydrophilicity, and hydration capability of prepared membranes were determined to illustrate the correlations between grafting qualities and hemocompatibility of PEGylated PVDF membranes in contact with human blood. Plasma protein adsorption onto different PEGylated PVDF membranes from single-protein solutions and the complex medium of 100% human plasma were measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Hemocompatibility of the PEGylated membranes was evaluated by the antifouling property of platelet adhesion observed by scanning electron microscopy (SEM) and the anticoagulant activity of the blood coagulant determined by testing plasma-clotting time. The control of grafting structures of PEGylated layers highly regulates the PVDF membrane to resist the adsorption of plasma proteins, the adhesion of platelets, and the coagulation of human plasma. It was found that PVDF membranes grafted with brush-like PEGylated layers presented higher hydration capability with binding water molecules than with network-like PEGylated layers to improve the hemocompatible character of plasma protein and blood platelet resistance in human blood. This work suggests that the hemocompatible nature of grafted PEGylated polymers by controlling grafting structures gives them great potential in the molecular design of antithrombogenic membranes for use in human blood.

  20. IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Tujin; Zhou, Jianying; Gritsenko, Marina A.

    2012-02-01

    Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up tomore » 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.« less

  1. Buffalo plasma fibronectin: a physico-chemical study.

    PubMed

    Ahmed, N; Chandra, R; Raj, H G

    2001-12-01

    Plasma fibronectin (FN) of buffalo (Babulis babulis) was purified to apparent homogeneity, using gelatin-Sepharose and heparin-Sepharose affinity columns. It was found to have two subunits of molecular mass 246 kDa and 228 kDa, on SDS-gel. Its immunological cross-reactivity with anti-human plasma FN was confirmed by Western blotting. The amino acid composition was found to be similar to that of human and bovine plasma FNs. Buffalo plasma FN contained 2.23% neutral hexoses and 1.18% sialic acids. No titrable sulfhydryl group could be detected in the absence of denaturant. Reaction with DTNB indicated 3.4 sulfhydryl groups in the molecule, whereas BDC-OH titration gave a value of 3.8 -SH groups in buffalo plasma FN. Stoke's radius, intrinsic viscosity, diffusion coefficient and frictional ratio indicated that buffalo plasma FN did not have a compact globular conformation at physiological pH and ionic strength. Molecular dimensions (average length, 120 nm; molar mass to length ratio, 3950 nm(-1) and mean diameter, 2.4 nm) as revealed by rotary shadowing electron microscopy further supported the extended conformation of buffalo plasma FN. These results show that buffalo plasma FN has similar properties as that of human plasma FN.

  2. In-Depth, Reproducible Analysis of Human Plasma Using IgY 14 and SuperMix Immunodepletion.

    PubMed

    Beer, Lynn A; Ky, Bonnie; Barnhart, Kurt T; Speicher, David W

    2017-01-01

    Identification of cancer and other disease biomarkers in human plasma has been exceptionally challenging due to the complex nature of plasma and the presence of a moderate number of high- and medium-abundance proteins which mask low-abundance proteins of interest. As a result, immunoaffinity depletion formats combining multiple antibodies to target the most abundant plasma proteins have become the first stage in most plasma proteome discovery schemes. This protocol describes the use of tandem IgY 14 and SuperMix immunoaffinity depletion to reproducibly remove >99% of total plasma protein. This greatly increases the depth of analysis of human plasma proteomes. Depleted plasma samples can then be analyzed in a single high-resolution LC-MS/MS run on a Q Exactive Plus mass spectrometer, followed by label-free quantitation. If greater depth of analysis is desired, the depleted plasma can be further fractionated by separating the sample for a short distance on a 1D SDS gel and cutting the gel into uniform slices prior to trypsin digestion. Alternatively, the depleted plasma can be reduced, alkylated, and digested with trypsin followed by high-pH reversed-phase HPLC separation.

  3. Multifunctional devices based on SnO2@rGO-coated fibers for human motion monitoring, ethanol detection, and photo response

    NASA Astrophysics Data System (ADS)

    Mi, Qing; Wang, Qi; Zang, Siyao; Chai, Zhaoer; Zhang, Jinnan; Ren, Xiaomin

    2018-05-01

    In this study, we developed a multifunctional device based on SnO2@rGO-coated fibers utilizing plasma treatment, dip coating, and microwave irradiation in sequence, and finally realized highly sensitive human motion monitoring, relatively good ethanol detection, and an obvious photo response. Moreover, the high level of comfort and compactness derived from highly elastic and comfortable fabrics contributes to the long-term availability and test accuracy. As an attempt at multifunctional integration of smart clothing, this work provides an attractive and relatively practical research direction.

  4. Multifunctional devices based on SnO2@rGO-coated fibers for human motion monitoring, ethanol detection, and photo response.

    PubMed

    Mi, Qing; Wang, Qi; Zang, Siyao; Chai, Zhaoer; Zhang, Jinnan; Ren, Xiaomin

    2018-05-11

    In this study, we developed a multifunctional device based on SnO 2 @rGO-coated fibers utilizing plasma treatment, dip coating, and microwave irradiation in sequence, and finally realized highly sensitive human motion monitoring, relatively good ethanol detection, and an obvious photo response. Moreover, the high level of comfort and compactness derived from highly elastic and comfortable fabrics contributes to the long-term availability and test accuracy. As an attempt at multifunctional integration of smart clothing, this work provides an attractive and relatively practical research direction.

  5. Clotting factor VIII (FVIII) and thrombin generation in camel plasma: A comparative study with humans

    PubMed Central

    Abdel Gader, Abdel Galil M.; Al Momen, Abdul Karim M.; Alhaider, Abdulqader; Brooks, Marjory B.; Catalfamo, James L.; Al Haidary, Ahmed A.; Hussain, Mansour F.

    2013-01-01

    The objective of this study was to characterize the highly elevated levels of clotting factor VIII (FVIII) in camel plasma. Whole blood was collected from healthy camels and factor VIII clotting activity (FVIII:C) assays were conducted using both the clotting and the chromogenic techniques. The anticoagulant citrate phosphate dextrose adenine (CPDA) produced the highest harvest of FVIII:C, the level of plasma factor VIII, compared to heparin:saline and heparin:CPDA anticoagulants. Camel FVIII can be concentrated 2 to 3 times in cryoprecipitate. There was a significant loss of camel FVIII when comparing levels of FVIII in camel plasma after 1 h of incubation at 37°C (533%), 40°C (364%), and 50°C (223%). Thrombin generation of camel plasma is comparable to that of human plasma. It was concluded that camel plasma contains very elevated levels of FVIII:C, approaching 8 times the levels in human plasma, and that these elevated levels could not be attributed to excessive thrombin generation. Unlike human FVIII:C, camel FVIII:C is remarkably heat stable. Taken together, these unique features of camel FVIII could be part of the physiological adaptation of hemostasis of the Arabian camel in order to survive in the hot desert environment. PMID:24082408

  6. A validated silver-nanoparticle-enhanced chemiluminescence method for the determination of citalopram in pharmaceutical preparations and human plasma.

    PubMed

    Khan, Muhammad Naeem; Jan, Muhammad Rasul; Shah, Jasmin; Lee, Sang Hak

    2014-05-01

    A simple and sensitive chemiluminescence (CL) method was developed for the determination of citalopram in pharmaceutical preparations and human plasma. The method is based on the enhancement of the weak CL signal of the luminol-H2 O2 system. It was found that the CL signal arising from the reaction between alkaline luminol and H2 O2 was greatly increased by the addition of silver nanoparticles in the presence of citalopram. Prepared silver nanoparticles (AgNPs) were characterized by UV-visible spectroscopy and transmission electron microscopy (TEM). Various experimental parameters affecting CL intensity were studied and optimized for the determination of citalopram. Under optimized experimental conditions, CL intensity was found to be proportional to the concentration of citalopram in the range 40-2500 ng/mL, with a correlation coefficient of 0.9997. The limit of detection (LOD) and limit of quantification (LOQ) of the devised method were 3.78 and 12.62 ng/mL, respectively. Furthermore, the developed method was found to have excellent reproducibility with a relative standard deviation (RSD) of 3.65% (n = 7). Potential interference by common excipients was also studied. The method was validated statistically using recovery studies and was successfully applied to the determination of citalopram in the pure form, in pharmaceutical preparations and in spiked human plasma samples. Percentage recoveries were found to range from 97.71 to 101.99% for the pure form, from 97.84 to 102.78% for pharmaceutical preparations and from 95.65 to 100.35% for spiked human plasma. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Mistimed food intake and sleep alters 24-hour time-of-day patterns of the human plasma proteome.

    PubMed

    Depner, Christopher M; Melanson, Edward L; McHill, Andrew W; Wright, Kenneth P

    2018-06-05

    Proteomics holds great promise for understanding human physiology, developing health biomarkers, and precision medicine. However, how much the plasma proteome varies with time of day and is regulated by the master circadian suprachiasmatic nucleus brain clock, assessed here by the melatonin rhythm, is largely unknown. Here, we assessed 24-h time-of-day patterns of human plasma proteins in six healthy men during daytime food intake and nighttime sleep in phase with the endogenous circadian clock (i.e., circadian alignment) versus daytime sleep and nighttime food intake out of phase with the endogenous circadian clock (i.e., circadian misalignment induced by simulated nightshift work). We identified 24-h time-of-day patterns in 573 of 1,129 proteins analyzed, with 30 proteins showing strong regulation by the circadian cycle. Relative to circadian alignment, the average abundance and/or 24-h time-of-day patterns of 127 proteins were altered during circadian misalignment. Altered proteins were associated with biological pathways involved in immune function, metabolism, and cancer. Of the 30 circadian-regulated proteins, the majority peaked between 1400 hours and 2100 hours, and these 30 proteins were associated with basic pathways involved in extracellular matrix organization, tyrosine kinase signaling, and signaling by receptor tyrosine-protein kinase erbB-2. Furthermore, circadian misalignment altered multiple proteins known to regulate glucose homeostasis and/or energy metabolism, with implications for altered metabolic physiology. Our findings demonstrate the circadian clock, the behavioral wake-sleep/food intake-fasting cycle, and interactions between these processes regulate 24-h time-of-day patterns of human plasma proteins and help identify mechanisms of circadian misalignment that may contribute to metabolic dysregulation.

  8. Pharmacokinetics, Metabolism, and Excretion of the Antiviral Drug Arbidol in Humans

    PubMed Central

    Deng, Pan; Zhong, Dafang; Yu, Kate; Zhang, Yifan; Wang, Ting

    2013-01-01

    Arbidol is a broad-spectrum antiviral drug that is used clinically to treat influenza. In this study, the pharmacokinetics, metabolism, and excretion of arbidol were investigated in healthy male Chinese volunteers after a single oral administration of 200 mg of arbidol hydrochloride. A total of 33 arbidol metabolites were identified in human plasma, urine, and feces. The principal biotransformation pathways included sulfoxidation, dimethylamine N-demethylation, glucuronidation, and sulfate conjugation. The major drug-related component in the plasma was sulfinylarbidol (M6-1), followed by unmetabolized arbidol, N-demethylsulfinylarbidol (M5), and sulfonylarbidol (M8). The exposures of M5, M6-1, and M8, as determined by the metabolite-to-parent area under the plasma concentration-time curve from 0 to t (AUC0-t) ratio, were 0.9 ± 0.3, 11.5 ± 3.6, and 0.5 ± 0.2, respectively. In human urine, glucuronide and sulfate conjugates were detected as the major metabolites, accounting for 6.3% of the dose excreted within 0 to 96 h after drug administration. The fecal specimens mainly contained the unchanged arbidol, accounting for 32.4% of the dose. Microsomal incubation experiments demonstrated that the liver and intestines were the major organs that metabolize arbidol in humans. CYP3A4 was the major isoform involved in arbidol metabolism, whereas the other P450s and flavin-containing monooxygenases (FMOs) played minor roles. These results indicated possible drug interactions between arbidol and CYP3A4 inhibitors and inducers. Further investigations are needed to understand the importance of M6-1 in the efficacy and safety of arbidol, because of its high plasma exposure and long elimination half-life (25.0 h). PMID:23357765

  9. Modulation of ileal bile acid transporter (ASBT) activity by depletion of plasma membrane cholesterol: association with lipid rafts

    PubMed Central

    Annaba, Fadi; Sarwar, Zaheer; Kumar, Pradeep; Saksena, Seema; Turner, Jerrold R.; Dudeja, Pradeep K.; Gill, Ravinder K.; Alrefai, Waddah A.

    2016-01-01

    Apical sodium-dependent bile acid transporter (ASBT) represents a highly efficient conservation mechanism of bile acids via mediation of their active transport across the luminal membrane of terminal ileum. To gain insight into the cellular regulation of ASBT, we investigated the association of ASBT with cholesterol and sphingolipid-enriched specialized plasma membrane microdomains known as lipid rafts and examined the role of membrane cholesterol in maintaining ASBT function. Human embryonic kidney (HEK)-293 cells stably transfected with human ASBT, human ileal brush-border membrane vesicles, and human intestinal epithelial Caco-2 cells were utilized for these studies. Floatation experiments on Optiprep density gradients demonstrated the association of ASBT protein with lipid rafts. Disruption of lipid rafts by depletion of membrane cholesterol with methyl-β-cyclodextrin (MβCD) significantly reduced the association of ASBT with lipid rafts, which was paralleled by a decrease in ASBT activity in Caco-2 and HEK-293 cells treated with MβCD. The inhibition in ASBT activity by MβCD was blocked in the cells treated with MβCD-cholesterol complexes. Kinetic analysis revealed that MβCD treatment decreased the Vmax of the transporter, which was not associated with alteration in the plasma membrane expression of ASBT. Our study illustrates that cholesterol content of lipid rafts is essential for the optimal activity of ASBT and support the association of ASBT with lipid rafts. These findings suggest a novel mechanism by which ASBT activity may be rapidly modulated by alterations in cholesterol content of plasma membrane and thus have important implications in processes related to maintenance of bile acid and cholesterol homeostasis. PMID:18063707

  10. Measurement of Plasma Nitrite by Chemiluminescence without Interference of S-, N-nitroso and Nitrated Species

    PubMed Central

    Nagababu, Enika; Rifkind, Joseph M.

    2009-01-01

    Recent studies have demonstrated that plasma nitrite (NO2-) reflects endothelial nitric oxide synthase activity and it has been proposed as a prognostic marker for cardiovascular disease. In addition, NO2- itself has been shown to have biological activities thought to be triggered by reduction back to NO in blood and tissues. The development of sensitive and reproducible methods for the quantitative determination of plasma NO2- is, therefore, of great importance. Ozone-based chemiluminescence assays have been shown to be highly sensitive for the determination of nanomolar quantities of NO and NO related species in biological fluids. We report here an improved direct chemiluminescence method for the determination of plasma NO2- without interference of other nitric oxide related species such as nitrate, S-nitrosothiols, N-nitrosamines, nitrated proteins and nitrated lipids. The method involves a reaction system consisting of glacial acetic acid and ascorbic acid in the purge vessel of the NO analyzer. Under these acidic conditions NO2- is stoichiometrically reduced to NO by ascorbic acid. Fasting human plasma NO2- values were found in the range of 56-210 nM (mean =110 ± 36 nM). This method has high sensitivity with an accuracy of 97% and high precision (C.V <10%) for determination of plasma nitrite. The present method is simple and highly specific for plasma NO2-. It is particularly suited to evaluate vasculature endothelial NO production that predicts the risks for cardiovascular disease. PMID:17382196

  11. Non-thermal plasma activates human keratinocytes by stimulation of antioxidant and phase II pathways.

    PubMed

    Schmidt, Anke; Dietrich, Stephan; Steuer, Anna; Weltmann, Klaus-Dieter; von Woedtke, Thomas; Masur, Kai; Wende, Kristian

    2015-03-13

    Non-thermal atmospheric pressure plasma provides a novel therapeutic opportunity to control redox-based processes, e.g. wound healing, cancer, and inflammatory diseases. By spatial and time-resolved delivery of reactive oxygen and nitrogen species, it allows stimulation or inhibition of cellular processes in biological systems. Our data show that both gene and protein expression is highly affected by non-thermal plasma. Nuclear factor erythroid-related factor 2 (NRF2) and phase II enzyme pathway components were found to act as key controllers orchestrating the cellular response in keratinocytes. Additionally, glutathione metabolism, which is a marker for NRF2-related signaling events, was affected. Among the most robustly increased genes and proteins, heme oxygenase 1, NADPH-quinone oxidoreductase 1, and growth factors were found. The roles of NRF2 targets, investigated by siRNA silencing, revealed that NRF2 acts as an important switch for sensing oxidative stress events. Moreover, the influence of non-thermal plasma on the NRF2 pathway prepares cells against exogenic noxae and increases their resilience against oxidative species. Via paracrine mechanisms, distant cells benefit from cell-cell communication. The finding that non-thermal plasma triggers hormesis-like processes in keratinocytes facilitates the understanding of plasma-tissue interaction and its clinical application. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. UHPLC-(ESI)QTOF MS/MS profiling of quercetin metabolites in human plasma postconsumption of applesauce enriched with apple peel and onion.

    PubMed

    Lee, Jihyun; Ebeler, Susan E; Zweigenbaum, Jerry A; Mitchell, Alyson E

    2012-08-29

    An ultrahigh pressure liquid chromatography accurate mass quadrupole time-of-flight mass spectrometry with electrospray ionization (UHPLC-(ESI)QTOF MS/MS) method was developed for measuring individual quercetin metabolites in human plasma with high sensitivity and high selectivity. Quercetin (3,3',4',5,7-pentahydroxyflavone) occurs as glycosides in foods. The composition of glycosides is species and cultivar specific. In humans, quercetin undergoes extensive biotransformation, resulting in a range of metabolites. The bioactivity of quercetin metabolites will depend on the type and position of the conjugates. Herein, individual quercetin metabolites (i.e., sulfate, glucuronide or methyl conjugates) were identified by accurate mass MS in human plasma (females = 8 and males = 8) over 24 h after consumption of applesauce enriched with either micronized apple peel (AP) or onion powder (OP). The AP and OP contained ~180 μmol of quercetin glycosides. The relative amounts of quercetin metabolites were quantified in plasma. The complement of identified quercetin metabolites was similar after consumption of AP and OP. Primary metabolites included the following: quercetin sulfate, quercetin glucuronide, and quercetin diglucuronide. A quercetin glutathione adduct was identified in negative ion mode but not apparent in positive ion mode. The pharmacokinetic parameters for AUC0-24 h and Cmax were significantly different for AP and OP. For example, consumption of the AP resulted in Cmax of quercetin sulfate, 4.6 ng/mL; quercetin glucuronide, 15.5 ng/mL; quercetin diglucuronide, 9.3 ng/mL; quercetin glucuronide sulfate, 1.3 ng/mL; methyl quercetin glucuronide, 7.5 ng/mL; and methyl quercetin diglucuronide, 3.6 ng/mL, whereas the OP resulted in Cmax of quercetin sulfate, 37.3 ng/mL; quercetin glucuronide, 212.8 ng/mL; quercetin diglucuronide, 168.8 ng/mL; quercetin glucuronide sulfate, 43.0 ng/mL; methyl quercetin glucuronide, 90.1 ng/mL; methyl quercetin diglucuronide, 65.4 ng/mL. Gender-related differences in the AUC0-24 h for quercetin sulfate and quercetin sulfate glucuronide metabolites were also observed.

  13. Effect of pilocarpine on substance P and calcitonin gene-related peptide releases correlate with salivary secretion in human saliva and plasma.

    PubMed

    Sato, Y; Itoh, H; Suzuki, Y; Tatsuta, R; Takeyama, M

    2013-02-01

    Pilocarpine, a muscarinic receptor agonist, has been used for the treatment of dry mouth. Salivary glands are supplied with nerve fibres that contain neuropeptides, such as substance P, calcitonin gene-related peptide (CGRP) and vasoactive intestinal polypeptide (VIP), which are important modulators of salivation. It is known that measurement of salivary and plasma levels of neuropeptides is useful for assessing the dose-pharmacological effect relationship of drugs. The relationship between the action of pilocarpine and neuropeptides in humans has not been studied. Moreover, studies evaluate the usefulness of drug salivary levels in the pharmacological evaluation of drugs are scarce. The aim of this study was to examine the effects of pilocarpine on the levels of substance P-, CGRP- and VIP-like immunoreactive substances (IS) in saliva and plasma taken in healthy humans. Five healthy male subjects participated in this study. Pilocarpine tablet (10 mg) or placebo tablet was orally administered with 100 mL of water. Each subject was administered placebo and drug with an interval of 4 weeks in between. Saliva was sampled before and at 20, 40, 60, 90, 120, 180 and 240 min after administration of the test substances. Venous blood samples (10 mL) were also taken from a forearm vein at each time interval. The samples were then enzyme immunoassayed using a highly sensitive system for substance P-, CGRP- and VIP-IS. The amount of saliva was measured by the Saxon test. A single oral administration of pilocarpine increased the release of salivary substance P-IS (the area under the concentration-time curve: AUC(0→240 min)) compared with the placebo. Pilocarpine also significantly increased the release of salivary CGRP-IS (AUC(0→240 min)). Pilocarpine significantly increased the release of plasma CGRP-IS. The salivary volume correlated with the salivary level of substance P and CGRP-IS (r = 0·84, P < 0·05 and r = 0·59, P < 0·05, respectively). AUC(0→240 min) for substance P-IS in saliva correlated with that for plasma (r = 0·78, P < 0·05). Pilocarpine increases the release of salivary substance P and CGRP-IS. This suggests that one mechanism by which pilocarpine improves dry mouth is by local stimulation of neuropeptidergic nerves. Moreover, saliva levels of substance P showed good correlation with the plasma levels. The substance P levels in saliva and plasma may be good indicators of the effects of drugs used in dry mouth/xerostomic patients. © 2012 Blackwell Publishing Ltd.

  14. Maternal and paternal plasma, salivary, and urinary oxytocin and parent-infant synchrony: considering stress and affiliation components of human bonding.

    PubMed

    Feldman, Ruth; Gordon, Ilanit; Zagoory-Sharon, Orna

    2011-07-01

    Studies in mammals have implicated the neuropeptide oxytocin (OT) in processes of bond formation and stress modulation, yet the involvement of OT in human bonding throughout life remains poorly understood. We assessed OT in the plasma, saliva, and urine of 112 mothers and fathers interacting with their 4-6-month-old infants. Parent-infant interactions were micro-coded for parent and child's social behaviors and for the temporal coordination of their socio-affective cues. Parents were interviewed regarding their attachment to the infant and reported on bonding to own parents, romantic attachment, and parenting stress. Results indicated that OT in plasma (pOT) and saliva (sOT) were inter-related and were unrelated to OT in urine (uOT). pOT and sOT in mothers and fathers were associated with parent and child's social engagement, affect synchrony, and positive communicative sequences between parent and child. uOT was related to moments of interactive stress among mothers only, indexed by the co-occurrence of infant negative engagement and mother re-engagement attempts. pOT and sOT were associated with mothers' and fathers' attachment relationships throughout life: to own parents, partner, and infant, whereas uOT correlated with relationship anxiety and parenting stress among mothers only. Similar to other mammals, OT is involved in human attachment and contingent parenting. The dual role of OT in stress and affiliation underscores its complex involvement in processes of social bonding throughout life. © 2010 Blackwell Publishing Ltd.

  15. High levels of exosomes expressing CD63 and caveolin-1 in plasma of melanoma patients.

    PubMed

    Logozzi, Mariantonia; De Milito, Angelo; Lugini, Luana; Borghi, Martina; Calabrò, Luana; Spada, Massimo; Perdicchio, Maurizio; Marino, Maria Lucia; Federici, Cristina; Iessi, Elisabetta; Brambilla, Daria; Venturi, Giulietta; Lozupone, Francesco; Santinami, Mario; Huber, Veronica; Maio, Michele; Rivoltini, Licia; Fais, Stefano

    2009-01-01

    Metastatic melanoma is an untreatable cancer lacking reliable and non-invasive markers of disease progression. Exosomes are small vesicles secreted by normal as well as tumor cells. Human tumor-derived exosomes are involved in malignant progression and we evaluated the presence of exosomes in plasma of melanoma patients as a potential tool for cancer screening and follow-up. We designed an in-house sandwich ELISA (Exotest) to capture and quantify exosomes in plasma based on expression of housekeeping proteins (CD63 and Rab-5b) and a tumor-associated marker (caveolin-1). Western blot and flow cytometry analysis of exosomes were used to confirm the Exotest-based findings. The Exotest allowed sensitive detection and quantification of exosomes purified from human tumor cell culture supernatants and plasma from SCID mice engrafted with human melanoma. Plasma levels of exosomes in melanoma-engrafted SCID mice correlated to tumor size. We evaluated the levels of plasma exosomes expressing CD63 and caveolin-1 in melanoma patients (n = 90) and healthy donors (n = 58). Consistently, plasma exosomes expressing CD63 (504+/-315) or caveolin-1 (619+/-310) were significantly increased in melanoma patients as compared to healthy donors (223+/-125 and 228+/-102, respectively). While the Exotest for CD63+ plasma exosomes had limited sensitivity (43%) the Exotest for detection of caveolin-1+ plasma exosomes showed a higher sensitivity (68%). Moreover, caveolin-1+ plasma exosomes were significantly increased with respect to CD63+ exosomes in the patients group. We describe a new non-invasive assay allowing detection and quantification of human exosomes in plasma of melanoma patients. Our results suggest that the Exotest for detection of plasma exosomes carrying tumor-associated antigens may represent a novel tool for clinical management of cancer patients.

  16. Immuno-spin trapping of heme-induced protein radicals: Implications for heme oxygenase-1 induction and heme degradation

    PubMed Central

    Ganini, Douglas; Deterding, Leesa J.; Ehrenshaft, Marilyn; Chatterjee, Saurabh; Mason, Ronald P.

    2013-01-01

    Heme, in the presence of hydrogen peroxide, can act as a peroxidase. Intravascular hemolysis results in a massive release of heme into the plasma in several pathophysiological conditions such as hemolytic anemia, malaria, and sickle cell disease. Heme is known to induce heme oxygenase-1(HO-1) expression, and the extent of induction depends on the ratio of albumin to heme in plasma. HO-1 degrades heme and ultimately generates the antioxidant bilirubin. Heme also causes oxidative stress in cells, but whether it causes protein-radical formation has not yet been studied. In the literature, two purposes for the degradation of heme by HO-1 are discussed. One is the production of the antioxidant bilirubin and the other is the prevention of heme-dependent adverse effects. Here we have investigated heme-induced protein-radical formation, which might have pathophysiological consequences, and have used immunospin trapping to establish the formation of heme-induced protein radicals in two systems: human serum albumin (HSA)/H2O2 and human plasma/H2O2.We found that excess heme catalyzed the formation of HSA radicals in the presence of hydrogen peroxide. When heme and hydrogen peroxide were added to human plasma, heme was found to oxidize proteins, primarily and predominantly HSA; however, when HSA-depleted plasma was used, heme triggered the oxidation of several other proteins, including transferrin. Thus, HSA in plasma protected other proteins from heme/H2O2-induced oxidation. The antioxidants ascorbate and uric acid significantly attenuated protein-radical formation induced by heme/ H2O2; however, bilirubin did not confer significant protection. Based on these findings, we conclude that heme is degraded by HO-1 because it is a catalyst of protein-radical formation and not merely to produce the relatively inefficient antioxidant bilirubin. PMID:23624303

  17. Pineal peptides restore the age-related disturbances in hormonal functions of the pineal gland and the pancreas.

    PubMed

    Goncharova, N D; Vengerin, A A; Khavinson, V Kh; Lapin, B A

    2005-01-01

    The purpose of this research was to study age-related changes in functioning of pineal and pancreatic glands of non-human primates, rhesus monkeys, and to elucidate the possibility of their corrections with the help of epitalon, a synthetic analogue of the pharmacopoeia drug epithalamin. In old (20-27 years) animals, the basal plasma levels of glucose and insulin were found to be higher, while the night melatonin level was lower in comparison with (6-8 years) young animals. After the glucose administration to old monkeys, a larger area under the curve of the plasma glucose response, a reduced glucose 'disappearance' rate, and a reduced insulin peak (5 min after the glucose administration) were observed in comparison with young animals in similar experiments. The epitalon administration to old monkeys caused the decrease in the basal levels of glucose and insulin and the increase in the basal night melatonin level. Additionally, in the case of old monkeys, epitalon decreased the area under the plasma glucose response curve, markedly increased the glucose 'disappearance' rate and normalized the plasma insulin dynamics in response to glucose administration. Yet, it has not affected the hormonal and metabolic changes in young animals. Thus, epitalon is a promising factor for restoring the age-related endocrine dysfunctions of primates.

  18. Sample Preparation Report of the Fourth OPCW Confidence Building Exercise on Biomedical Sample Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Udey, R. N.; Corzett, T. H.; Alcaraz, A.

    Following the successful completion of the 3rd biomedical confidence building exercise (February 2013 – March 2013), which included the analysis of plasma and urine samples spiked at low ppb levels as part of the exercise scenario, another confidence building exercise was targeted to be conducted in 2014. In this 4th exercise, it was desired to focus specifically on the analysis of plasma samples. The scenario was designed as an investigation of an alleged use of chemical weapons where plasma samples were collected, as plasma has been reported to contain CWA adducts which remain present in the human body for severalmore » weeks (Solano et al. 2008). In the 3rd exercise most participants used the fluoride regeneration method to analyze for the presence of nerve agents in plasma samples. For the 4th biomedical exercise it was decided to evaluate the analysis of human plasma samples for the presence/absence of the VX adducts and aged adducts to blood proteins (e.g., VX-butyrylcholinesterase (BuChE) and aged BuChE adducts using a pepsin digest technique to yield nonapeptides; or equivalent). As the aging of VX-BuChE adducts is relatively slow (t1/2 = 77 hr at 37 °C [Aurbek et al. 2009]), soman (GD), which ages much more quickly (t1/2 = 9 min at 37 °C [Masson et al. 2010]), was used to simulate an aged VX sample. Additional objectives of this exercise included having laboratories assess novel OP-adducted plasma sample preparation techniques and analytical instrumentation methodologies, as well as refining/designating the reporting formats for these new techniques.« less

  19. Simultaneous analysis of thiamphenicol and its prodrug thiamphenicol glycinate in human plasma and urine by high performance liquid chromatography: application to pharmacokinetic study.

    PubMed

    Chen, Xijing; Yang, Bing; Ni, Liang; Wang, Guangji

    2006-06-07

    A simple and sensitive method for simultaneous determination of the active compound, thiamphenicol (TAP) and its prodrug, thiamphenicol glycinate (TG) in human plasma and urine is described. The procedure involved extraction of TG and TAP with ethyl acetate (plasma) or 100-fold dilution with the mobile phase (urine) followed by determination by reversed-phase high performance liquid chromatography (HPLC) with UV detection at 224 nm. Separation of the compounds was achieved on a column packed with Hypersil ODS2. The mobile phase consisted of acetonitrile-water containing 0.003 M tetrabutyl ammonium bromide and 0.056 M ammonium acetate (87:13, v/v) with a flow rate of 1.0 ml/min. The chromatograms did not contain interfering peaks due to the suitable extraction procedure and chromatographic conditions. The calibration curves of TG and TAP were linear ranging from 0.78 to 100 microg/ml in plasma and in urine. The intra-day and inter-day relative standard deviations (S.D.) were less than 10%. The recoveries of TG and TAP in plasma and urine were above 80%. TG was not stable in plasma samples and after extraction at ambient temperature or in freeze-thaw cycles, and hence the samples for injection on HPLC column should be stored in refrigerator or under ice cooling prior to analysis, and the plasma samples should not experience the freeze-thaw cycle more than one time. Unlike TAP, TG could not be detected in most urine samples. Application of this method demonstrated that it was feasible for the clinical pharmacokinetic study.

  20. The effect of the plasma needle on the human keratinocytes related to the wound healing process

    NASA Astrophysics Data System (ADS)

    Korolov, Ihor; Fazekas, Barbara; Széll, Márta; Kemény, Lajos; Kutasi, Kinga

    2016-01-01

    In the present study we aim to verify the influence of a non-thermal atmospheric pressure plasma on the wound healing process. In this process the major contributors are the keratinocytes, which migrate to fill in the gap created by the wound. Therefore, we performed the direct treatment of HPV-immortalized human keratinocytes, protected by a layer of phosphate buffered saline (PBS) solution, with the glow discharge generated in flowing helium by a plasma needle. To mimick a wound, a 4 mm scratch was performed on the cell culture (scratch assay). We conducted two types of experiments: (i) cell proliferation and (ii) wound-healing model experiments. The plasma needle configuration, the plasma treatment conditions and the thickness of the protecting PBS layer were set based on viability experiments. The proliferation studies showed that short, 5-10 s, and low power treatments, such as 18 W and 20 W input power, could positively influence the cell proliferation when keratinocytes were protected by PBS. On the other hand, the plasma treatment of cell medium covered keratinocytes resulted in the decrease of proliferation. The wound-healing model (scratch assay) studies showed, that there was a maximum in the wound reduction as a function of the input power and treatment time, namely, at 18 W and 5 s. Furthermore, the wound reduction strongly depended on the treated cell—PBS interaction time. To mimic an infected wound, the scratch assay was covered with a 1× {{10}9} cfu ml-1 Propionibacterium acnes suspension. The plasma treatment of this infected assay resulted in closing of the scratch, while in the non-treated assay the wound did not close at all.

  1. Cell Surface Expression of Human Ether-a-go-go-related Gene (hERG) Channels Is Regulated by Caveolin-3 Protein via the Ubiquitin Ligase Nedd4-2*

    PubMed Central

    Guo, Jun; Wang, Tingzhong; Li, Xian; Shallow, Heidi; Yang, Tonghua; Li, Wentao; Xu, Jianmin; Fridman, Michael D.; Yang, Xiaolong; Zhang, Shetuan

    2012-01-01

    The human ether-a-go-go-related gene (hERG) encodes the rapidly activating delayed rectifier potassium channel (IKr) which plays an important role in cardiac repolarization. A reduction or increase in hERG current can cause long or short QT syndrome, respectively, leading to fatal cardiac arrhythmias. The channel density in the plasma membrane is a key determinant of the whole cell current amplitude. To gain insight into the molecular mechanisms for the regulation of hERG density at the plasma membrane, we used whole cell voltage clamp, Western blotting, and immunocytochemical methods to investigate the effects of an integral membrane protein, caveolin-3 (Cav3) on hERG expression levels. Our data demonstrate that Cav3, hERG, and ubiquitin-ligase Nedd4-2 interact with each other and form a complex. Expression of Cav3 thus enhances the hERG-Nedd4-2 interaction, leading to an increased ubiquitination and degradation of mature, plasma-membrane localized hERG channels. Disrupting Nedd4-2 interaction with hERG by mutations eliminates the effects of Cav3 on hERG channels. Knockdown of endogenous Cav3 or Nedd4-2 in cultured neonatal rat ventricular myocytes using siRNA led to an increase in native IKr. Our data demonstrate that hERG expression in the plasma membrane is regulated by Cav3 via Nedd4-2. These findings extend our understanding of the regulation of hERG channels and cardiac electrophysiology. PMID:22879586

  2. Human in Vivo pharmacokinetics of [ 14C]Dibenzo[ def,p]chrysene by accelerator mass spectrometry following oral microdosing

    DOE PAGES

    Madeen, Erin; Corley, Richard A.; Crowell, Susan; ...

    2014-11-24

    Dibenzo( def,p)chrysene (DBC), (also known as dibenzo[a,l]pyrene), is a high molecular weight polycyclic aromatic hydrocarbon (PAH) found in the environment, including food, produced by the incomplete combustion of hydrocarbons. DBC, classified by IARC as a 2A probable human carcinogen, has a relative potency factor (RPF) in animal cancer models 30-fold higher than benzo[ a]pyrene. No data are available describing the disposition of high molecular weight (>4 rings) PAHs in humans to compare to animal studies. Pharmacokinetics of DBC was determined in 3 female and 6 male human volunteers following oral microdosing (29 ng, 5 nCi) of [ 14C]-DBC. This studymore » was made possible with highly sensitive accelerator mass spectrometry (AMS), capable of detecting [ 14C]-DBC equivalents in plasma and urine following a dose considered of de minimus risk to human health. Plasma and urine were collected over 72 h. The plasma C max was 68.8 ± 44.3 fg·mL –1 with a T max of 2.25 ± 1.04 h. Elimination occurred in two distinct phases: a rapid (α)-phase, with a T 1/2 of 5.8 ± 3.4 h and an apparent elimination rate constant (K el) of 0.17 ± 0.12 fg·h –1, followed by a slower (β)-phase, with a T 1/2 of 41.3 ± 29.8 h and an apparent K el of 0.03 ± 0.02 fg·h –1. In spite of the high degree of hydrophobicity (log Kow of 7.4), DBC was eliminated rapidly in humans, as are most PAHs in animals, compared to other hydrophobic persistent organic pollutants such as, DDT, PCBs and TCDD. Preliminary examination utilizing a new UHPLC-AMS interface, suggests the presence of polar metabolites in plasma as early as 45 min following dosing. Finally, this is the first in vivo data set describing pharmacokinetics in humans of a high molecular weight PAH and should be a valuable addition to risk assessment paradigms.« less

  3. Human in Vivo pharmacokinetics of [ 14C]Dibenzo[ def,p]chrysene by accelerator mass spectrometry following oral microdosing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madeen, Erin; Corley, Richard A.; Crowell, Susan

    Dibenzo( def,p)chrysene (DBC), (also known as dibenzo[a,l]pyrene), is a high molecular weight polycyclic aromatic hydrocarbon (PAH) found in the environment, including food, produced by the incomplete combustion of hydrocarbons. DBC, classified by IARC as a 2A probable human carcinogen, has a relative potency factor (RPF) in animal cancer models 30-fold higher than benzo[ a]pyrene. No data are available describing the disposition of high molecular weight (>4 rings) PAHs in humans to compare to animal studies. Pharmacokinetics of DBC was determined in 3 female and 6 male human volunteers following oral microdosing (29 ng, 5 nCi) of [ 14C]-DBC. This studymore » was made possible with highly sensitive accelerator mass spectrometry (AMS), capable of detecting [ 14C]-DBC equivalents in plasma and urine following a dose considered of de minimus risk to human health. Plasma and urine were collected over 72 h. The plasma C max was 68.8 ± 44.3 fg·mL –1 with a T max of 2.25 ± 1.04 h. Elimination occurred in two distinct phases: a rapid (α)-phase, with a T 1/2 of 5.8 ± 3.4 h and an apparent elimination rate constant (K el) of 0.17 ± 0.12 fg·h –1, followed by a slower (β)-phase, with a T 1/2 of 41.3 ± 29.8 h and an apparent K el of 0.03 ± 0.02 fg·h –1. In spite of the high degree of hydrophobicity (log Kow of 7.4), DBC was eliminated rapidly in humans, as are most PAHs in animals, compared to other hydrophobic persistent organic pollutants such as, DDT, PCBs and TCDD. Preliminary examination utilizing a new UHPLC-AMS interface, suggests the presence of polar metabolites in plasma as early as 45 min following dosing. Finally, this is the first in vivo data set describing pharmacokinetics in humans of a high molecular weight PAH and should be a valuable addition to risk assessment paradigms.« less

  4. Effects of acute exposure to increased plasma branched-chain amino acid concentrations on insulin-mediated plasma glucose turnover in healthy young subjects.

    PubMed

    Everman, Sarah; Mandarino, Lawrence J; Carroll, Chad C; Katsanos, Christos S

    2015-01-01

    Plasma branched-chain amino acids (BCAA) are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity. To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans. Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U) during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5) to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5). In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U) in association with the above BCAA infusion (N = 4) or under the same conditions without BCAA infusion (N = 3). Plasma glucose turnover was measured prior to and during insulin infusion. Insulin infusion completely suppressed the endogenous glucose production (EGP) across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05). Insulin infusion stimulated whole-body glucose disposal rate (GDR) across all groups. However, the increase (%) in GDR was not different [median (1st quartile - 3rd quartile)] between Control and BCAA in either the 40U ([199 (167-278) vs. 186 (94-308)] or 80 U ([491 (414-548) vs. 478 (409-857)] experiments (P > 0.05). Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P < 0.05) with no differences between Control and BCAA in either of the experiments (P > 0.05). Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism.

  5. A green method using a micellar system for determination of andrographolide and dehydroandrographolide in human plasma.

    PubMed

    Zhao, Qi; Ding, Jie; Jin, Haiyan; Ding, Lan; Ren, Nanqi

    2013-04-01

    A method based on cloud point extraction (CPE) coupled with high-performance liquid chromatography separation and ultraviolet (UV) detection was developed to determine andrographolide and dehydroandrographolide in human plasma. The nonionic surfactant Triton X-114 was chosen as the extraction medium. Variable parameters affecting the CPE efficiency were evaluated and optimized, such as concentrations of Triton X-114 and NaCl, pH, equilibration temperature and equilibration time. A Zorbax SB C18 column (250 × 4.6 mm i.d., 5 µm) was used for separation of the two analytes at 30°C. The UV detection was performed at 254 nm. Under the optimum conditions, the limits of detection of andrographolide and dehydroandrographolide are 0.032 and 0.019 µg/mL, respectively. The intra-day and inter-day precisions expressed as relative standard deviation ranged from 3.2 to 7.3% and from 2.9 and 8.6%. The recoveries of andrographolide and dehydroandrographolide were in the range of 76.8-98.6% at three fortified concentrations of 0.1, 0.5 and 1.0 µg/mL. This method was efficient, environmentally friendly, rapid and inexpensive for the extraction and determination of andrographolide and dehydroandrographolide in human plasma.

  6. Identification of vinculin as a potential plasma marker for age-related macular degeneration.

    PubMed

    Kim, Hye-Jung; Woo, Se Joon; Suh, Eui Jin; Ahn, Jeeyun; Park, Ji Hyun; Hong, Hye Kyoung; Lee, Ji Eun; Ahn, Seong Joon; Hwang, Duck Jin; Kim, Ki Woong; Park, Kyu Hyung; Lee, Cheolju

    2014-10-08

    To identify plasma protein biomarkers for age-related macular degeneration (AMD) using a large-scale quantitative proteomic discovery procedure. Plasma proteomes from 20 exudative AMD patients and 20 healthy control patients were comparatively profiled by four-dimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS). Proteins existing at statistically different levels were validated by enzyme-linked immunosorbent assay (ELISA) and Western blotting in 233 case-controlled samples. Newly discovered plasma biomarkers were further confirmed using in vivo and in vitro experiments. Out of 320 proteins identified, vinculin, protein S100A9, triosephosphate isomerase, protein S100A8, protein Z-dependent protease inhibitor, C-X-C motif chemokine 7, and tenascin X showed significantly differential expression in AMD patient plasma compared to control plasma. Among these, the area under the curve (AUC) for vinculin was 0.871 for discriminating between exudative AMD and controls (n = 201) and 0.879 for discriminating between AMD and controls (n = 233). A proteogenomic combination model using vinculin and two known risk genotypes in ARMS2 and CFH genes additionally provided excellent discrimination of AMD from controls (AUC = 0.916). The plasma level of vinculin was not associated with any confounding clinical variables, such as age, smoking, and other comorbidities. Additionally, vinculin was strongly expressed in retinal pigment epithelial cells of human eyes, and its expression was elevated when exposed to oxidative stress in vitro. Vinculin was identified as a potential plasma biomarker for AMD. The early detection of AMD using novel plasma biomarkers with genetic modeling may enable timely treatment and vision preservation in the elderly. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  7. Physical activity opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension.

    PubMed

    Nyberg, M; Mortensen, S P; Hellsten, Y

    2013-03-01

    Endothelin-1 has potent constrictor and proliferative activity in vascular smooth muscle, and essential hypertension and aging are associated with increased endothelin-1-mediated vasoconstrictor tone. The aim of this study was to investigate the effect of physical activity, hypertension and age on endothelin-1 levels in plasma and skeletal muscle and endothelin receptors in skeletal muscle in human subjects. In study 1, normotensive (46 ± 1 years, n = 11) and hypertensive (47 ± 1 years, n = 10) subjects were studied before and after 8 weeks of aerobic exercise training. In study 2, young (23 ± 1 years, n = 8), older lifelong sedentary (66 ± 2 years, n = 8) and older lifelong endurance-trained (62 ± 2 years, n = 8) subjects were studied in a cross-sectional design. Skeletal muscle and plasma endothelin-1 levels were increased with age and plasma endothelin-1 levels were higher in hypertensive than normotensive individuals. Eight weeks of exercise training normalized plasma endothelin-1 levels in the hypertensive subjects and increased the protein expression of the ET(A) receptor in skeletal muscle of normotensive subjects. Similarly, individuals that had performed lifelong physical activity had similar plasma and muscle endothelin-1 levels as the young controls and had higher ET(A) receptor levels. Our findings suggest that aerobic exercise training opposes the age-related increase in skeletal muscle and plasma endothelin-1 levels and normalizes plasma endothelin-1 levels in individuals with essential hypertension. This effect may explain some of the beneficial effects of training on the cardiovascular system in older and hypertensive subjects. © 2012 The Authors Acta Physiologica © 2012 Scandinavian Physiological Society.

  8. Therapeutic plasma concentrations of epsilon aminocaproic acid and tranexamic acid in horses.

    PubMed

    Fletcher, D J; Brainard, B M; Epstein, K; Radcliffe, R; Divers, T

    2013-01-01

    Antifibrinolytic drugs such as epsilon aminocaproic acid (EACA) and tranexamic acid (TEA) are used to treat various bleeding disorders in horses. Although horses are hypofibrinolytic compared to humans, dosing schemes have been derived from pharmacokinetic studies targeting plasma concentrations in humans. We hypothesized therapeutic plasma concentrations of antifibrinolytic drugs in horses would be significantly lower than in humans. Our objective was to use thromboleastography (TEG) and an in vitro model of hyperfibrinolysis to predict therapeutic concentrations of EACA and TEA in horses and humans. Citrated plasma collected from 24 random source clinically healthy research horses. Commercial pooled human citrated plasma with normal coagulation parameters was purchased. Minimum tissue plasminogen activator (tPA) concentration to induce complete fibrinolysis within 10 minutes was determined using serial dilutions of tPA in equine plasma. Results used to create an in vitro hyperfibrinolysis model with equine and human citrated plasma, and the minimum concentrations of EACA and TEA required to completely inhibit fibrinolysis for 30 minutes (estimated therapeutic concentrations) determined using serial dilutions of the drugs. Estimated therapeutic concentrations of EACA and TEA were significantly lower in horses (5.82; 95% CI 3.77-7.86 μg/mL and 0.512; 95% CI 0.277-0.748 μg/mL) than in humans (113.2; 95% CI 95.8-130.6 μg/mL and 11.4; 95% CI 8.62-14.1 μg/mL). Current dosing schemes for EACA and TEA in horses may be as much as 20× higher than necessary, potentially increasing cost of treatment and risk of adverse effects. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  9. Electrospun fibrous thin film microextraction coupled with desorption corona beam ionization-mass spectrometry for rapid analysis of antidepressants in human plasma.

    PubMed

    Chen, Di; Hu, Yu-Ning; Hussain, Dilshad; Zhu, Gang-Tian; Huang, Yun-Qing; Feng, Yu-Qi

    2016-05-15

    Appropriate sample preparations prior to analysis can significantly enhance the sensitivity of ambient ionization techniques, especially during the enrichment or purification of analytes in the presence of complex biological matrix. Here in, we developed a rapid analysis method by the combination of thin film microextraction (TFME) and desorption corona beam ionization (DCBI) for the determination of antidepressants in human plasma. Thin films used for extraction consisted of sub-micron sized highly ordered mesoporous silica-carbon composite fibers (OMSCFs), simply prepared by electrospinning and subsequent carbonization. Typically, OMSCFs thin film was immersed into the diluted plasma for extraction of target analytes and then directly subjected to the DCBI-MS for detection. Size-exclusion effect of mesopores contributed to avoid of the protein precipitation step prior to extraction. Mass transfer was benefited from high surface-to-volume ratio which is attributed to macroporous network and ordered mesostructures. Moreover, the OMSCFs provided mixed-mode hydrophobic/ion-exchange interactions towards target analytes. Thus, the detection sensitivity was greatly improved due to effective enrichment of the target analytes and elimination of matrix interferences. After optimization of several parameters related to extraction performance, the proposed method was eventually applied for the determination of three antidepressants in human plasma. The calibration curves were plotted in the range of 5-1000 ng/mL with acceptable linearity (R(2) >0.983). The limits of detection (S/N=3) of three antidepressants were in ranges of 0.3-1 ng/mL. Reproducibility was achieved with RSD less than 17.6% and the relative recoveries were in ranges of 83.6-116.9%. Taken together, TFME-DCBI-MS method offers a powerful capacity for rapid analysis to achieve much-improved sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. In Vivo Characterization of Human APOA5 Haplotypes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahituv, Nadav; Akiyama, Jennifer; Chapman-Helleboid, Audrey

    2006-10-01

    Increased plasma triglycerides concentrations are an independent risk factor for cardiovascular disease. Numerous studies support a reproducible genetic association between two minor haplotypes in the human apolipoprotein A5 gene (APOA5) and increased plasma triglyceride concentrations. We thus sought to investigate the effect of these minor haplotypes (APOA5*2 and APOA5*3) on ApoAV plasma levels through the precise insertion of single-copy intact APOA5 haplotypes at a targeted location in the mouse genome. While we found no difference in the amount of human plasma ApoAV in mice containing the common APOA5*1 and minor APOA5*2 haplotype, the introduction of the single APOA5*3 defining allelemore » (19W) resulted in 3-fold lower ApoAV plasma levels consistent with existing genetic association studies. These results indicate that S19W polymorphism is likely to be functional and explain the strong association of this variant with plasma triglycerides supporting the value of sensitive in vivo assays to define the functional nature of human haplotypes.« less

  11. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    PubMed

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Enhanced cytokine synthesis of leukocytes by a beta-glucan preparation, SCG, extracted from a medicinal mushroom, Sparassis crispa.

    PubMed

    Nameda, Sachiko; Harada, Toshie; Miura, Noriko N; Adachi, Yoshiyuki; Yadomae, Toshiro; Nakajima, Mitsuhiro; Ohno, Naohito

    2003-08-01

    Sparassis crispa is edible mushroom recently cultivable in Japan. It contains significantly high content (approximately 40%) of 6-branched 1,3-beta-D-glucan showing antitumor activity in mice. We recently purified a beta-glucan preparation designated as "SCG." It was considered worth while to test SCG in vitro with whole blood collected from human volunteers. The present study is focusing on the cytokine productivity of SCG in an in vitro human system. The following results were observed: (i) SCG dose dependently enhanced IL-8 synthesis of whole blood cell culture of human peripheral blood. (ii) IL-8 synthesis was enhanced in both PBMC and PMN cultures. (iii) IL-8 synthesis was induced in the culture with autologous plasma, but significantly reduced after 56 degrees C treatment. (iv) The activity was also weak in heat inactivated fetal calf serum (FCS). (v) A complement fragment, C5a, was released by SCG dependently upon dose and kinetics. (vi) Anti-SCG natural antibody was detected in human plasma. From these facts, SCG was observed to have the capacity to activate human leukocytes and related immune system.

  13. Comparison of GLUT1, GLUT3, and GLUT4 mRNA and the subcellular distribution of their proteins in normal human muscle

    NASA Technical Reports Server (NTRS)

    Stuart, C. A.; Wen, G.; Gustafson, W. C.; Thompson, E. A.

    2000-01-01

    Basal, "insulin-independent" glucose uptake into skeletal muscle is provided by glucose transporters positioned at the plasma membrane. The relative amount of the three glucose transporters expressed in muscle has not been previously quantified. Using a combination of qualitative and quantitative ribonuclease protection assay (RPA) methods, we found in normal human muscle that GLUT1, GLUT3, and GLUT4 mRNA were expressed at 90 +/- 10, 46 +/- 4, and 156 +/- 12 copies/ng RNA, respectively. Muscle was fractionated by DNase digestion and differential sedimentation into membrane fractions enriched in plasma membranes (PM) or low-density microsomes (LDM). GLUT1 and GLUT4 proteins were distributed 57% to 67% in LDM, whereas GLUT3 protein was at least 88% in the PM-enriched fractions. These data suggest that basal glucose uptake into resting human muscle could be provided in part by each of these three isoforms.

  14. [Proliferation and osteogenic differentiation of mesenchymal stem cells in hydrogels of human blood plasma].

    PubMed

    Linero, Itali M; Doncel, Adriana; Chaparro, Orlando

    2014-01-01

    The use of mesenchymal stem cells in clinical practice has increased considerably in the last decade because they play a supporting role in the processes of tissue repair and regeneration, becoming the main tool of cell therapy for the treatment of diseases functionally affecting bone and cartilage tissue . To evaluate in vitro the proliferative and osteogenic differentiation ability of mesenchymal stem cells derived from human adipose tissue in a blood plasma hydrogel. Mesenchymal stem cells were obtained from human adipose tissue explants and characterized by flow cytometry. Their multipotentiality was demonstrated by their ability to differentiate to adipogenic and osteogenic lineages. Cell proliferation and osteogenic differentiation ability of the cells cultured in blood plasma hydrogels were also evaluated. Mesenchymal stem cells derived from human adipose tissue growing in human blood plasma hydrogels showed a pattern of proliferation similar to that of the cells cultured in monolayer and also maintained their ability to differentiate to osteogenic lineage. Human blood plasma hydrogels are a suitable support for proliferation and osteogenic differentiation of mesenchymal stem cells derived from human adipose tissue and provides a substrate that is autologous, biocompatible, reabsorbable, easy to use, potentially injectable and economic, which could be used as a successful strategy for the management and clinical application of cell therapy in regenerative medicine.

  15. The identification of Trypanosoma brucei gambiense in Liberian pigs and dogs by isoenzymes and by resistance to human plasma.

    PubMed

    Gibson, W; Mehlitz, D; Lanham, S M; Godfrey, D G

    1978-09-01

    29 Trypanozoon stocks from Liberian pigs and dogs were screened for human plasma resistance and electrophoretic isoenzyme patterns of eleven enzymes. Two stocks from pigs were found both to be resistant to human plasma and to have an isoenzyme marker, a slow alanine aminotransferase (ALAT) pattern, previously found only in Trypanosoma brucei gambiense from man. This constitutes evidence that the pig is a reservoir of human trypanosomiasis in West Africa. The T.b.gambiense ALAT was also found in stocks from 5 other pigs and a dog, but none of these stocks was resistant to human plasma; conversely, 9 further isolations from pigs and 2 from dogs were plasma resistant but did not have the T.b.gambiense ALAT. The lack of correspondence between the two characteristics is discussed. A T.b.gambiense stock from man in Zaire had the ALAT pattern characteristic of T.b.gambiense from Senegal and Nigeria, together with the ASAT triplet found in most T.b.gambiense stocks. Peptidase polymorphism was shown in trypanosomes for the first time.

  16. Effect of long-term exposure to pesticides on plasma esterases from plastic greenhouse workers.

    PubMed

    Hernández, Antonio; Gómez, M Amparo; Pena, Gloria; Gil, Fernando; Rodrigo, Lourdes; Villanueva, Enrique; Pla, Antonio

    2004-07-23

    Previous reports in animals considered beta-glucuronidase activity as a novel biomarker of anticholinesterase (organophosphates and carbamates) pesticides exposure. Acid phosphatase activity was also shown to increase after organophosphates exposure. In addition, there is evidence that the paraoxonase status influences sensitivity to specific pesticides. In this study, activities of beta-glucuronidase, acid phosphatase, cholinesterase, and paraoxonase were measured in plasma from plastic greenhouse workers exposed over the long term to different pesticides, including organophosphates and carbamates, in order to evaluate the potential chronic toxicity of pesticides at occupational level. Our results show that activities of paraoxonase and cholinesterase were decreased in applicators of pesticides compared to non-applicators. Likewise, it was found that activities of beta-glucuronidase and acid phosphatase were associated with pesticide exposure in humans, and that both biochemical parameters were related to each other. Interestingly, the paraoxonase B allele (phenotyped in plasma) was associated with a higher risk of inhibition of cholinesterase activity above a 25% level, which supports the hypothesis that paraoxonase phenotypes are associated with susceptibility of humans to anticholinesterase pesticides toxicity. Copyright Taylor and Francis Inc.

  17. Ultrasonic and electromagnetic enhancement of a culture of human SAOS-2 osteoblasts seeded onto a titanium plasma-spray surface.

    PubMed

    Fassina, Lorenzo; Saino, Enrica; Sbarra, Maria Sonia; Visai, Livia; Cusella De Angelis, Maria Gabriella; Mazzini, Giuliano; Benazzo, Francesco; Magenes, Giovanni

    2009-06-01

    Several studies suggest that the surface coating of titanium could play an important role in bone tissue engineering. In the present study, we have followed a particular biomimetic strategy where ultrasonically or electromagnetically stimulated SAOS-2 human osteoblasts proliferated and built their extracellular matrix on a titanium plasma-spray surface. In comparison with control conditions, the ultrasonic stimulation (average power, 149 mW; frequency, 1.5 MHz) and the electromagnetic stimulation (magnetic field intensity, 2 mT; frequency, 75 Hz) caused higher cell proliferation, and increased surface coating with decorin, osteocalcin, osteopontin, and type I collagen together with higher incorporation of calcium and phosphorus inside the extracellular matrix. The immunofluorescence related to the preceding bone matrix proteins showed their colocalization in the cell-rich areas. The use of the two physical stimulations aimed at obtaining the coating of the rough titanium plasma-spray surface in terms of cell colonization and deposition of extracellular matrix. The superficially cultured biomaterial could be theoretically used, in clinical applications, as an implant for bone repair.

  18. Complement proteins bind to nanoparticle protein corona and undergo dynamic exchange in vivo

    NASA Astrophysics Data System (ADS)

    Chen, Fangfang; Wang, Guankui; Griffin, James I.; Brenneman, Barbara; Banda, Nirmal K.; Holers, V. Michael; Backos, Donald S.; Wu, Linping; Moghimi, Seyed Moein; Simberg, Dmitri

    2017-05-01

    When nanoparticles are intravenously injected into the body, complement proteins deposit on the surface of nanoparticles in a process called opsonization. These proteins prime the particle for removal by immune cells and may contribute toward infusion-related adverse effects such as allergic responses. The ways complement proteins assemble on nanoparticles have remained unclear. Here, we show that dextran-coated superparamagnetic iron oxide core-shell nanoworms incubated in human serum and plasma are rapidly opsonized with the third complement component (C3) via the alternative pathway. Serum and plasma proteins bound to the nanoworms are mostly intercalated into the nanoworm shell. We show that C3 covalently binds to these absorbed proteins rather than the dextran shell and the protein-bound C3 undergoes dynamic exchange in vitro. Surface-bound proteins accelerate the assembly of the complement components of the alternative pathway on the nanoworm surface. When nanoworms pre-coated with human plasma were injected into mice, C3 and other adsorbed proteins undergo rapid loss. Our results provide important insight into dynamics of protein adsorption and complement opsonization of nanomedicines.

  19. Increasing fetal ovine number per gestation alters fetal plasma clinical chemistry values.

    PubMed

    Zywicki, Micaela; Blohowiak, Sharon E; Magness, Ronald R; Segar, Jeffrey L; Kling, Pamela J

    2016-08-01

    Intrauterine growth restriction (IUGR) is interconnected with developmental programming of lifelong pathophysiology. IUGR is seen in human multifetal pregnancies, with stepwise rises in fetal numbers interfering with placental nutrient delivery. It remains unknown whether fetal blood analyses would reflect fetal nutrition, liver, and excretory function in the last trimester of human or ovine IUGR In an ovine model, we hypothesized that fetal plasma biochemical values would reflect progressive placental, fetal liver, and fetal kidney dysfunction as the number of fetuses per gestation rose. To determine fetal plasma biochemical values in singleton, twin, triplet, and quadruplet/quintuplet ovine gestation, we investigated morphometric measures and comprehensive metabolic panels with nutritional measures, liver enzymes, and placental and fetal kidney excretory measures at gestational day (GD) 130 (90% gestation). As anticipated, placental dysfunction was supported by a stepwise fall in fetal weight, fetal plasma glucose, and triglyceride levels as fetal number per ewe rose. Fetal glucose and triglycerides were directly related to fetal weight. Plasma creatinine, reflecting fetal renal excretory function, and plasma cholesterol, reflecting placental excretory function, were inversely correlated with fetal weight. Progressive biochemical disturbances and growth restriction accompanied the rise in fetal number. Understanding the compensatory and adaptive responses of growth-restricted fetuses at the biochemical level may help explain how metabolic pathways in growth restriction can be predetermined at birth. This physiological understanding is important for clinical care and generating interventional strategies to prevent altered developmental programming in multifetal gestation. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  20. Plasma substance P levels in patients with persistent cough.

    PubMed

    Otsuka, Kojiro; Niimi, Akio; Matsumoto, Hisako; Ito, Isao; Yamaguchi, Masafumi; Matsuoka, Hirofumi; Jinnai, Makiko; Oguma, Tsuyoshi; Takeda, Tomoshi; Nakaji, Hitoshi; Chin, Kazuo; Sasaki, Kazuhiko; Aoyama, Norihito; Mishima, Michiaki

    2011-01-01

    Substance P (SP) is involved in the pathogenesis of cough in animal models. However, few studies in humans have been reported and the roles of SP in clinical cough remain obscure. To clarify the relevance of plasma levels of SP in patients with persistent cough. We studied 82 patients with cough persisting for at least 3 weeks and 15 healthy controls. Patients were classified as having asthmatic cough (cough-variant asthma and cough-predominant asthma; n = 61) or nonasthmatic cough (n = 21; postinfectious cough, n = 6; gastroesophageal reflux disease, n = 5; idiopathic cough, n = 5, and others, n = 5). Correlations were evaluated between plasma SP levels as measured with ELISA and methacholine airway hyperresponsiveness (airway sensitivity and airway reactivity), capsaicin cough sensitivity, sputum eosinophil and neutrophil counts, and pulmonary function. Plasma SP levels were significantly elevated in patients with both asthmatic and nonasthmatic cough compared with controls [31.1 pg/ml (range 18.0-52.2) and 30.0 pg/ml (range 15.1-50.3) vs. 15.4 pg/ml (range 11.3-23.7); p = 0.003 and p = 0.038, respectively] but did not differ between the two patient groups (p = 0.90). Plasma SP levels correlated with airway sensitivity (threshold dose of methacholine) in the patients with asthmatic cough (r = -0.37, p = 0.005) but not with airway reactivity, cough sensitivity, FEV1 values, or sputum eosinophil and neutrophil counts in either group. Increased levels of SP in plasma are associated with persistent cough in humans and might be related to airway sensitivity in asthmatic cough. Copyright © 2011 S. Karger AG, Basel.

  1. Development of a Rapid LC-MS/MS Method for the Determination of Emerging Fusarium mycotoxins Enniatins and Beauvericin in Human Biological Fluids

    PubMed Central

    Serrano, Ana Belén; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2015-01-01

    A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%–103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R2 of 0.991–0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L−1 and 40 ng·L−1 in plasma and between 5 ng·L−1 and 20 ng·L−1 in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors. PMID:26371043

  2. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-03-01

    A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Cold atmospheric plasma treatment inhibits growth in colorectal cancer cells.

    PubMed

    Schneider, Christin; Arndt, Stephanie; Zimmermann, Julia L; Li, Yangfang; Karrer, Sigrid; Bosserhoff, Anja-Katrin

    2018-06-01

    Plasma oncology is a relatively new field of research. Recent developments have indicated that cold atmospheric plasma (CAP) technology is an interesting new therapeutic approach to cancer treatment. In this study, p53 wildtype (LoVo) and human p53 mutated (HT29 and SW480) colorectal cancer cells were treated with the miniFlatPlaSter - a device particularly developed for the treatment of tumor cells - that uses the Surface Micro Discharge (SMD) technology for plasma production in air. The present study analyzed the effects of plasma on colorectal cancer cells in vitro and on normal colon tissue ex vivo. Plasma treatment had strong effects on colon cancer cells, such as inhibition of cell proliferation, induction of cell death, and modulation of p21 expression. In contrast, CAP treatment of murine colon tissue ex vivo for up to 2 min did not show any toxic effect on normal colon cells compared to H2O2 positive control. In summary, these results suggest that the miniFlatPlaSter plasma device is able to kill colorectal cancer cells independent of their p53 mutation status. Thus, this device presents a promising new approach in colon cancer therapy.

  4. Association of plasma manganese levels with chronic renal failure.

    PubMed

    Sánchez-González, Cristina; López-Chaves, Carlos; Gómez-Aracena, Jorge; Galindo, Pilar; Aranda, Pilar; Llopis, Juan

    2015-01-01

    Manganese (Mn) is an essential trace element involved in the formation of bone and in amino acid, lipid and carbohydrate metabolism. Mn excess may be neurotoxic to humans, affecting specific areas of the central nervous system. However, relatively little is known about its physiological and/or toxicological effects, and very few data are available concerning the role of Mn in chronic renal failure (CRF). This paper describes a 12-month study of the evolution of plasma Mn levels in predialysis patients with CRF and the relationship with energy and macronutrient intake. The participants in this trial were 64 patients with CRF in predialysis and 62 healthy controls. Plasma levels of creatinine, urea, uric acid, total protein and Mn were measured. The glomerular filtration rate (GFR) was calculated using the Cockcroft-Gault index. The CRF patients had higher plasma levels of creatinine, urea, uric acid and Mn and a lower GFR than the controls. Plasma Mn was positively correlated with creatinine, plasma urea and plasma uric acid and was negatively correlated with the GFR and the intake of energy and macronutrients. In conclusion, CRF in predialysis patients is associated with increases in circulating levels of Mn. Copyright © 2015 Elsevier GmbH. All rights reserved.

  5. Relationship of low plasma klotho with poor grip strength in older community-dwelling adults: the InCHIANTI study

    PubMed Central

    Semba, Richard D.; Cappola, Anne R.; Sun, Kai; Bandinelli, Stefania; Dalal, Mansi; Crasto, Candace; Guralnik, Jack M.; Ferrucci, Luigi

    2012-01-01

    Handgrip strength is a strong indicator of total body muscle strength and is a predictor of poor outcomes in older adults. The aging suppressor gene klotho encodes a single-pass transmembrane protein that is secreted as a circulating hormone. In mice, disruption of klotho expression results in a syndrome that includes sarcopenia, atherosclerosis, osteoporosis, and shortened lifespan, and conversely, overexpression of klotho leads to a greater longevity. The objective was to determine whether plasma klotho levels are related to skeletal muscle strength in humans. We measured plasma klotho in 804 adults, ≥65 years, in the InCHIANTI study, a longitudinal population-based study of aging in Tuscany, Italy. Grip strength was positively correlated with plasma klotho at threshold <681 pg/mL. After adjusting for age, sex, education, smoking, physical activity, cognition, and chronic diseases, plasma klotho (per 1 standard deviation increase) was associated with grip strength (beta = 1.20, standard error = 0.35, P = 0.0009) in adults with plasma klotho <681 pg/mL. These results suggest that older adults with lower plasma klotho have poor skeletal muscle strength. PMID:21769735

  6. A novel workflow combining plaque imaging, plaque and plasma proteomics identifies biomarkers of human coronary atherosclerotic plaque disruption.

    PubMed

    Lee, Regent; Fischer, Roman; Charles, Philip D; Adlam, David; Valli, Alessandro; Di Gleria, Katalin; Kharbanda, Rajesh K; Choudhury, Robin P; Antoniades, Charalambos; Kessler, Benedikt M; Channon, Keith M

    2017-01-01

    Atherosclerotic plaque rupture is the culprit event which underpins most acute vascular syndromes such as acute myocardial infarction. Novel biomarkers of plaque rupture could improve biological understanding and clinical management of patients presenting with possible acute vascular syndromes but such biomarker(s) remain elusive. Investigation of biomarkers in the context of de novo plaque rupture in humans is confounded by the inability to attribute the plaque rupture as the source of biomarker release, as plaque ruptures are typically associated with prompt down-stream events of myocardial necrosis and systemic inflammation. We developed a novel approach to identify potential biomarkers of plaque rupture by integrating plaque imaging, using optical coherence tomography, with both plaque and plasma proteomic analysis in a human model of angioplasty-induced plaque disruption. We compared two pairs of coronary plaque debris, captured by a FilterWire Device, and their corresponding control samples and found matrix metalloproteinase 9 (MMP9) to be significantly enriched in plaque. Plaque contents, as defined by optical coherence tomography, affect the systemic changes of MMP9. Disruption of lipid-rich plaque led to prompt elevation of plasma MMP9, whereas disruption of non-lipid-rich plaque resulted in delayed elevation of plasma MMP9. Systemic MMP9 elevation is independent of the associated myocardial necrosis and systemic inflammation (measured by Troponin I and C-reactive protein, respectively). This information guided the selection of a subset of subjects of for further label free proteomics analysis by liquid chromatography tandem mass spectrometry (LC-MS/MS). We discovered five novel, plaque-enriched proteins (lipopolysaccharide binding protein, Annexin A5, eukaryotic translocation initiation factor, syntaxin 11, cytochrome B5 reductase 3) to be significantly elevated in systemic circulation at 5 min after plaque disruption. This novel approach for biomarker discovery in human coronary artery plaque disruption can identify new biomarkers related to human coronary artery plaque composition and disruption.

  7. Suppression of plasma virus load below the detection limit of a human immunodeficiency virus kit is associated with longer virologic response than suppression below the limit of quantitation.

    PubMed

    Raboud, J M; Rae, S; Hogg, R S; Yip, B; Sherlock, C H; Harrigan, P R; O'Shaughnessy, M V; Montaner, J S

    1999-10-01

    Suppression of human immunodeficiency virus type 1 plasma virus load (PVL) to <20 copies/mL is associated with a longer virologic response after initiation of antiretroviral therapy. The relationship between duration of virologic response and PVL nadir according to a less sensitive assay was explored. When compared with subjects with a PVL nadir >500 copies/mL, the relative risks of PVL rising above 1000 copies/mL for participants in the INCAS trial and the British Columbia Drug Treatment Program with a PVL nadir below the limit of detection (LOD) were 0.04 (95% confidence interval [CI], 0.02-0.09) and 0.06 (95% CI, 0.03-0.12), respectively. The corresponding relative risks for persons with a detectable but not quantifiable PVL nadir were 0.25 (95% CI, 0.13-0.50) and 0.54 (95% CI, 0.25-1.19). The relative risks of virologic failure associated with a PVL nadir detectable but not quantifiable and a PVL nadir below the LOD were statistically different (P<.0001) in both data sets.

  8. Metabolic profiles of pomalidomide in human plasma simulated with pharmacokinetic data in control and humanized-liver mice.

    PubMed

    Shimizu, Makiko; Suemizu, Hiroshi; Mitsui, Marina; Shibata, Norio; Guengerich, F Peter; Yamazaki, Hiroshi

    2017-10-01

    1. Pomalidomide has been shown to be potentially teratogenic in thalidomide-sensitive animal species such as rabbits. Screening for thalidomide analogs devoid of teratogenicity/toxicity - attributable to metabolites formed by cytochrome P450 enzymes - but having immunomodulatory properties is a strategic pathway towards development of new anticancer drugs. 2. In this study, plasma concentrations of pomalidomide, its primary 5-hydroxylated metabolite, and its glucuronide conjugate(s) were investigated in control and humanized-liver mice. Following oral administration of pomalidomide (100 mg/kg), plasma concentrations of 7-hydroxypomalidomide and 5-hydroxypomalidomide glucuronide were slightly higher in humanized-liver mice than in control mice. 3. Simulations of human plasma concentrations of pomalidomide were achieved with simplified physiologically-based pharmacokinetic models in both groups of mice in accordance with reported pomalidomide concentrations after low dose administration in humans. 4. The results indicate that pharmacokinetic profiles of pomalidomide were roughly similar between control mice and humanized-liver mice and that control and humanized-liver mice mediated pomalidomide 5-hydroxylation in vivo. Introducing one aromatic amino group into thalidomide resulted in less species differences in in vivo pharmacokinetics in control and humanized-liver mice.

  9. Sensitive method for the quantitation of droloxifene in plasma and serum by high-performance liquid chromatography employing fluorimetric detection.

    PubMed

    Tess, D A; Cole, R O; Toler, S M

    1995-12-15

    A simple and highly sensitive reversed-phase fluorimetric HPLC method for the quantitation of droloxifene from rat, monkey, and human plasma as well as human serum is described. This assay employs solid-phase extraction and has a dynamic range of 25 to 10,000 pg/ml. Sample extraction (efficiencies > 86%) was accomplished using a benzenesulfonic acid (SCX) column with water and methanol rinses. Droloxifene and internal standard were eluted with 1 ml of 3.5% (v/v) ammonium hydroxide (30%) in methanol. Samples were quantitated using post-column UV-photochemical cyclization coupled with fluorimetric detection with excitation and emission wavelengths of 260 nm and 375 nm, respectively. Relative ease of sample extraction and short run times allow for the analysis of approximately 100 samples per day.

  10. A standardized kit for automated quantitative assessment of candidate protein biomarkers in human plasma.

    PubMed

    Percy, Andrew J; Mohammed, Yassene; Yang, Juncong; Borchers, Christoph H

    2015-12-01

    An increasingly popular mass spectrometry-based quantitative approach for health-related research in the biomedical field involves the use of stable isotope-labeled standards (SIS) and multiple/selected reaction monitoring (MRM/SRM). To improve inter-laboratory precision and enable more widespread use of this 'absolute' quantitative technique in disease-biomarker assessment studies, methods must be standardized. Results/methodology: Using this MRM-with-SIS-peptide approach, we developed an automated method (encompassing sample preparation, processing and analysis) for quantifying 76 candidate protein markers (spanning >4 orders of magnitude in concentration) in neat human plasma. The assembled biomarker assessment kit - the 'BAK-76' - contains the essential materials (SIS mixes), methods (for acquisition and analysis), and tools (Qualis-SIS software) for performing biomarker discovery or verification studies in a rapid and standardized manner.

  11. Radioimmunoassay of human high molecular weight kininogen in normal and deficient plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Proud, D.; Pierce, J.V.; Pisano, J.J.

    1980-04-01

    An RIA for human HMW kininogen, capable of detecting 150 pg of antigen, has been developed. Antibody to HMW kininogen was purified by immunoaffinity chromatography, and double-antibody precipitation was used to separate free and bound antigen. Of the LMW kininogens only one of the forms tested (B3.2) showed significant cross-reaction (2%). Bradykinin and human plasma kallikrein both showed no cross-reaction, and monkey HMW kininogen showed identity to the human antigen. Intraassay and interassay coefficients of variation were 2 and 1.5%, respectively. Recovery of HMW kininogen added to 6 plasmas was 97.7% +- 1.8%. Assay of 17 normal plasmas gave amore » level of 90.8 +- 2.5 ..mu..g/ml HMW kininogen (mean +- S.E.M.). A bioassay of the samples, based on specific release of kinin by purified plasma kallikrein, yielded a level of 90.2 +- 2.8 ..mu..g/ml HMW kininogen (r = 0.83, p < 0.001). In neither assay was any significant sex difference observed. No evidence of any antigenic fragments was seen upon gel filtration of normal plasmas. RIA measurements were also performed on seven plasmas reportedly deficient in HMW kininogen. Williams, Dayton, San Francisco, and Flaujeac plasmas all showed no significant cross-reaction, whereas Fitzgerald, Reid, and Detroit plasmas showed 1.0, 2.5, and 3.5% of normal antigenic levels, respectively. This sensitive, convenient method should facilitate studies on the role of the kallikrein-kinin system in health and disease.« less

  12. Effects of nelfinavir and its M8 metabolite on lymphocyte P-glycoprotein activity during antiretroviral therapy.

    PubMed

    Donahue, John P; Dowdy, David; Ratnam, Krishna K; Hulgan, Todd; Price, James; Unutmaz, Derya; Nicotera, Janet; Raffanti, Steven; Becker, Mark; Haas, David W

    2003-01-01

    The efflux pump P-glycoprotein decreases drug penetration into cells and tissues. To determine whether nelfinavir or its metabolites inhibit P-glycoprotein in lymphocytes from a healthy volunteer, whole blood cells from human immunodeficiency virus-negative donors were incubated either in human plasma to which nelfinavir or its M8 metabolite were added ex vivo or in plasma from human immunodeficiency virus-positive patients receiving nelfinavir. The 50% P-glycoprotein inhibitory concentrations of purified nelfinavir and M8 were 10.9 micromol/L and 29.5 micromol/L, respectively, for CD4(+) T cells and 19.3 micromol/L and >48 micromol/L, respectively, for CD8(+) T cells. Significant inhibitory activity was present in plasma from 27 of 46 patients (59%) receiving nelfinavir. Plasma nelfinavir concentrations correlated with percent inhibition on CD4(+) (rho = 0.85, P <.0001) and CD8(+) (rho = 0.83, P <.0001) T cells. The M8 concentrations correlated weakly with both inhibition and nelfinavir concentrations. On the basis of our findings in lymphocytes from a healthy volunteer exposed to plasma from human immunodeficiency virus-positive patients, we believe it is likely that CD4(+) and CD8(+) lymphocytes in patients receiving nelfinavir as therapy for human immunodeficiency virus may have P-glycoprotein inhibited by plasma concentrations of nelfinavir.

  13. Statistical Analysis of Variation in the Human Plasma Proteome

    DOE PAGES

    Corzett, Todd H.; Fodor, Imola K.; Choi, Megan W.; ...

    2010-01-01

    Quantifying the variation in the human plasma proteome is an essential prerequisite for disease-specific biomarker detection. We report here on the longitudinal and individual variation in human plasma characterized by two-dimensional difference gel electrophoresis (2-D DIGE) using plasma samples from eleven healthy subjects collected three times over a two week period. Fixed-effects modeling was used to remove dye and gel variability. Mixed-effects modeling was then used to quantitate the sources of proteomic variation. The subject-to-subject variation represented the largest variance component, while the time-within-subject variation was comparable to the experimental variation found in a previous technical variability study where onemore » human plasma sample was processed eight times in parallel and each was then analyzed by 2-D DIGE in triplicate. Here, 21 protein spots had larger than 50% CV, suggesting that these proteins may not be appropriate as biomarkers and should be carefully scrutinized in future studies. Seventy-eight protein spots showing differential protein levels between different individuals or individual collections were identified by mass spectrometry and further characterized using hierarchical clustering. The results present a first step toward understanding the complexity of longitudinal and individual variation in the human plasma proteome, and provide a baseline for improved biomarker discovery.« less

  14. Statistical analysis of variation in the human plasma proteome.

    PubMed

    Corzett, Todd H; Fodor, Imola K; Choi, Megan W; Walsworth, Vicki L; Turteltaub, Kenneth W; McCutchen-Maloney, Sandra L; Chromy, Brett A

    2010-01-01

    Quantifying the variation in the human plasma proteome is an essential prerequisite for disease-specific biomarker detection. We report here on the longitudinal and individual variation in human plasma characterized by two-dimensional difference gel electrophoresis (2-D DIGE) using plasma samples from eleven healthy subjects collected three times over a two week period. Fixed-effects modeling was used to remove dye and gel variability. Mixed-effects modeling was then used to quantitate the sources of proteomic variation. The subject-to-subject variation represented the largest variance component, while the time-within-subject variation was comparable to the experimental variation found in a previous technical variability study where one human plasma sample was processed eight times in parallel and each was then analyzed by 2-D DIGE in triplicate. Here, 21 protein spots had larger than 50% CV, suggesting that these proteins may not be appropriate as biomarkers and should be carefully scrutinized in future studies. Seventy-eight protein spots showing differential protein levels between different individuals or individual collections were identified by mass spectrometry and further characterized using hierarchical clustering. The results present a first step toward understanding the complexity of longitudinal and individual variation in the human plasma proteome, and provide a baseline for improved biomarker discovery.

  15. Differential Responses of Plasma Adropin Concentrations To Dietary Glucose or Fructose Consumption In Humans

    PubMed Central

    Butler, Andrew A.; St-Onge, Marie-Pierre; Siebert, Emily A.; Medici, Valentina; Stanhope, Kimber L.; Havel, Peter J.

    2015-01-01

    Adropin is a peptide hormone encoded by the Energy Homeostasis Associated (ENHO) gene whose physiological role in humans remains incompletely defined. Here we investigated the impact of dietary interventions that affect systemic glucose and lipid metabolism on plasma adropin concentrations in humans. Consumption of glucose or fructose as 25% of daily energy requirements (E) differentially affected plasma adropin concentrations (P < 0.005) irrespective of duration, sex or age. Glucose consumption reduced plasma adropin from 3.55 ± 0.26 to 3.28 ± 0.23 ng/ml (N = 42). Fructose consumption increased plasma adropin from 3.63 ± 0.29 to 3.93 ± 0.34 ng/ml (N = 45). Consumption of high fructose corn syrup (HFCS) as 25% E had no effect (3.43 ± 0.32 versus 3.39 ± 0.24 ng/ml, N = 26). Overall, the effect of glucose, HFCS and fructose on circulating adropin concentrations were similar to those observed on postprandial plasma triglyceride concentrations. Furthermore, increases in plasma adropin levels with fructose intake were most robust in individuals exhibiting hypertriglyceridemia. Individuals with low plasma adropin concentrations also exhibited rapid increases in plasma levels following consumption of breakfasts supplemented with lipids. These are the first results linking plasma adropin levels with dietary sugar intake in humans, with the impact of fructose consumption linked to systemic triglyceride metabolism. In addition, dietary fat intake may also increase circulating adropin concentrations. PMID:26435060

  16. High-performance metabolic profiling of plasma from seven mammalian species for simultaneous environmental chemical surveillance and bioeffect monitoring.

    PubMed

    Park, Youngja H; Lee, Kichun; Soltow, Quinlyn A; Strobel, Frederick H; Brigham, Kenneth L; Parker, Richard E; Wilson, Mark E; Sutliff, Roy L; Mansfield, Keith G; Wachtman, Lynn M; Ziegler, Thomas R; Jones, Dean P

    2012-05-16

    High-performance metabolic profiling (HPMP) by Fourier-transform mass spectrometry coupled to liquid chromatography gives relative quantification of thousands of chemicals in biologic samples but has had little development for use in toxicology research. In principle, the approach could be useful to detect complex metabolic response patterns to toxicologic exposures and to detect unusual abundances or patterns of potentially toxic chemicals. As an initial study to develop these possible uses, we applied HPMP and bioinformatics analysis to plasma of humans, rhesus macaques, marmosets, pigs, sheep, rats and mice to determine: (1) whether more chemicals are detected in humans living in a less controlled environment than captive species and (2) whether a subset of plasma chemicals with similar inter-species and intra-species variation could be identified for use in comparative toxicology. Results show that the number of chemicals detected was similar in humans (3221) and other species (range 2537-3373). Metabolite patterns were most similar within species and separated samples according to family and order. A total of 1485 chemicals were common to all species; 37% of these matched chemicals in human metabolomic databases and included chemicals in 137 out of 146 human metabolic pathways. Probability-based modularity clustering separated 644 chemicals, including many endogenous metabolites, with inter-species variation similar to intra-species variation. The remaining chemicals had greater inter-species variation and included environmental chemicals as well as GSH and methionine. Together, the data suggest that HPMP provides a platform that can be useful within human populations and controlled animal studies to simultaneously evaluate environmental exposures and biological responses to such exposures. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. What can be learned in the snake antivenom field from the developments in human plasma derived products?

    PubMed

    Burnouf, Thierry

    2018-05-01

    Human plasma-derived medicinal products and snake antivenom immunoglobulins are unique and complex therapeutic protein products. Human plasma products are obtained by fractionating large pools of plasma collected from blood plasma donors. They comprise a wide range of protein products, including polyvalent and hyperimmune immunoglobulins, coagulation factors, albumin, and various protease inhibitors that are transfused to patients affected by congenital or acquired protein deficiencies, immunological disorders, or metabolic diseases. Snake antivenoms are manufactured from pools of plasma collected from animals, typically horses, which have been immunized against snake venoms. Transfusing antivenoms is the cornerstone therapy to treat patients affected by snakebite envenoming. Over the last thirty years, much technical and regulatory evolution has been implemented to ensure that this class of biologicals meets modern quality requirements. The purpose of this review is to compare the main developments that took place in plasma production, protein fractionation, pathogen safety, quality control, preclinical and clinical studies, and regulations of these products. We also analyze whether both fields have been influencing and cross-fertilizing each other technically and in regulatory aspects to reach modern safety and efficacy standards at global levels, and how experience in the human plasma fractionation industry can further impact the manufacture of snake antivenom and that of other animal-derived antisera. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Plasma concentrations of inflammatory cytokines rise rapidly during ECMO-related SIRS due to the release of preformed stores in the intestine.

    PubMed

    McILwain, R Britt; Timpa, Joseph G; Kurundkar, Ashish R; Holt, David W; Kelly, David R; Hartman, Yolanda E; Neel, Mary Lauren; Karnatak, Rajendra K; Schelonka, Robert L; Anantharamaiah, G M; Killingsworth, Cheryl R; Maheshwari, Akhil

    2010-01-01

    Extracorporeal membrane oxygenation (ECMO) is a life-saving support system used in neonates and young children with severe cardiorespiratory failure. Although ECMO has reduced mortality in these critically ill patients, almost all patients treated with ECMO develop a systemic inflammatory response syndrome (SIRS) characterized by a 'cytokine storm', leukocyte activation, and multisystem organ dysfunction. We used a neonatal porcine model of ECMO to investigate whether rising plasma concentrations of inflammatory cytokines during ECMO reflect de novo synthesis of these mediators in inflamed tissues, and therefore, can be used to assess the severity of ECMO-related SIRS. Previously healthy piglets (3-week-old) were subjected to venoarterial ECMO for up to 8 h. SIRS was assessed by histopathological analysis, measurement of neutrophil activation (flow cytometry), plasma cytokine concentrations (enzyme immunoassays), and tissue expression of inflammatory genes (PCR/western blots). Mast cell degranulation was investigated by measurement of plasma tryptase activity. Porcine neonatal ECMO was associated with systemic inflammatory changes similar to those seen in human neonates. Tumor necrosis factor-alpha (TNF-alpha) and interleukin-8 (IL-8) concentrations rose rapidly during the first 2 h of ECMO, faster than the tissue expression of these cytokines. ECMO was associated with increased plasma mast cell tryptase activity, indicating that increased plasma concentrations of inflammatory cytokines during ECMO may result from mast cell degranulation and associated release of preformed cytokines stored in mast cells. TNF-alpha and IL-8 concentrations rose faster in plasma than in the peripheral tissues during ECMO, indicating that rising plasma levels of these cytokines immediately after the initiation of ECMO may not reflect increasing tissue synthesis of these cytokines. Mobilization of preformed cellular stores of inflammatory cytokines such as in mucosal mast cells may have an important pathophysiological role in ECMO-related SIRS.

  19. 21 CFR 640.34 - Processing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...

  20. 21 CFR 640.34 - Processing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...

  1. 21 CFR 640.34 - Processing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...

  2. 21 CFR 640.34 - Processing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...

  3. 21 CFR 640.34 - Processing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...

  4. Bleeding Disorders Treatment Options

    MedlinePlus

    ... rare bleeding disorders are usually made from human plasma and are treated to eliminate viruses like HIV ... made in the laboratory and not from human plasma, so they carry no risk of infectious disease. ...

  5. 21 CFR 640.94 - Labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.94 Labeling. In addition... package labels shall contain the following information: (a) The osmotic equivalent in terms of plasma, and...

  6. 21 CFR 640.94 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.94 Labeling. In addition... package labels shall contain the following information: (a) The osmotic equivalent in terms of plasma, and...

  7. 21 CFR 640.94 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.94 Labeling. In addition... package labels shall contain the following information: (a) The osmotic equivalent in terms of plasma, and...

  8. 21 CFR 640.94 - Labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.94 Labeling. In addition... package labels shall contain the following information: (a) The osmotic equivalent in terms of plasma, and...

  9. 21 CFR 640.94 - Labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.94 Labeling. In addition... package labels shall contain the following information: (a) The osmotic equivalent in terms of plasma, and...

  10. The Impact of the Glomerular Filtration Rate on the Human Plasma Proteome.

    PubMed

    Christensson, Anders; Ash, Jessica A; DeLisle, Robert K; Gaspar, Fraser W; Ostroff, Rachel; Grubb, Anders; Lindström, Veronica; Bruun, Laila; Williams, Steve A

    2018-05-01

    The application of proteomics in chronic kidney disease (CKD) can potentially uncover biomarkers and pathways that are predictive of disease. Within this context, this study examines the relationship between the human plasma proteome and glomerular filtration rate (GFR) as measured by iohexol clearance in a cohort from Sweden (n = 389; GFR range: 8-100 mL min -1 /1.73 m 2 ). A total of 2893 proteins are quantified using a modified aptamer assay. A large proportion of the proteome is associated with GFR, reinforcing the concept that CKD affects multiple physiological systems (individual protein-GFR correlations listed here). Of these, cystatin C shows the most significant correlation with GFR (rho = -0.85, p = 1.2 × 10 -97 ), establishing strong validation for the use of this biomarker in CKD diagnostics. Among the other highly significant protein markers are insulin-like growth factor-binding protein 6, neuroblastoma suppressor of tumorigenicity 1, follistatin-related protein 3, trefoil factor 3, and beta-2 microglobulin. These proteins may indicate an imbalance in homeostasis across a variety of cellular processes, which may be underlying renal dysfunction. Overall, this study represents the most extensive characterization of the plasma proteome and its relation to GFR to date, and suggests the diagnostic and prognostic value of proteomics for CKD across all stages. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Experimental prestorage filtration removes antibodies and decreases lipids in RBC supernatants mitigating TRALI in vivo

    PubMed Central

    Kelher, Marguerite R.; Khan, Samina Y.; LaSarre, Monica; West, F. Bernadette; Land, Kevin J.; Mish, Barbara; Ceriano, Linda; Sowemimo-Coker, Samuel

    2014-01-01

    Transfusion-related acute lung injury (TRALI) remains a significant cause of transfusion-related mortality with red cell transfusion. We hypothesize that prestorage filtration may reduce proinflammatory activity in the red blood cell (RBC) supernatant and prevent TRALI. Filters were manufactured for both small volumes and RBC units. Plasma containing antibodies to human lymphocyte antigen (HLA)-A2 or human neutrophil antigen (HNA)-3a was filtered, and immunoglobulins and specific HNA-3a and HLA-2a neutrophil (PMN) priming activity were measured. Antibodies to OX27 were added to plasma, and filtration was evaluated in a 2-event animal model of TRALI. RBC units from 31 donors known to have antibodies against HLA antigens and from 16 antibody-negative controls were filtered. Furthermore, 4 RBC units were drawn and underwent standard leukoreduction. Immunoglobulins, HLA antibodies, PMN priming activity, and the ability to induce TRALI in an animal model were measured. Small-volume filtration of plasma removed >96% of IgG, antibodies to HLA-A2 and HNA-3a, and their respective priming activity, as well as mitigating antibody-mediated in vivo TRALI. In RBC units, experimental filtration removed antibodies to HLA antigens and inhibited the accumulation of lipid priming activity and lipid-mediated TRALI. We conclude that filtration removes proinflammatory activity and the ability to induce TRALI from RBCs and may represent a TRALI mitigation step. PMID:24747436

  12. Anion Channel Inhibitor NPPB-Inhibited Fluoride Accumulation in Tea Plant (Camellia sinensis) Is Related to the Regulation of Ca2+, CaM and Depolarization of Plasma Membrane Potential

    PubMed Central

    Zhang, Xian-Chen; Gao, Hong-Jian; Yang, Tian-Yuan; Wu, Hong-Hong; Wang, Yu-Mei; Zhang, Zheng-Zhu; Wan, Xiao-Chun

    2016-01-01

    Tea plant is known to be a hyper-accumulator of fluoride (F). Over-intake of F has been shown to have adverse effects on human health, e.g., dental fluorosis. Thus, understanding the mechanisms fluoride accumulation and developing potential approaches to decrease F uptake in tea plants might be beneficial for human health. In the present study, we found that pretreatment with the anion channel inhibitor NPPB reduced F accumulation in tea plants. Simultaneously, we observed that NPPB triggered Ca2+ efflux from mature zone of tea root and significantly increased relative CaM in tea roots. Besides, pretreatment with the Ca2+ chelator (EGTA) and CaM antagonists (CPZ and TFP) suppressed NPPB-elevated cytosolic Ca2+ fluorescence intensity and CaM concentration in tea roots, respectively. Interestingly, NPPB-inhibited F accumulation was found to be significantly alleviated in tea plants pretreated with either Ca2+ chelator (EGTA) or CaM antagonists (CPZ and TFP). In addition, NPPB significantly depolarized membrane potential transiently and we argue that the net Ca2+ and H+ efflux across the plasma membrane contributed to the restoration of membrane potential. Overall, our results suggest that regulation of Ca2+-CaM and plasma membrane potential depolarization are involved in NPPB-inhibited F accumulation in tea plants. PMID:26742036

  13. Optimization of alcohol-assisted dispersive liquid-liquid microextraction by experimental design for the rapid determination of fluoxetine in biological samples.

    PubMed

    Hamedi, Raheleh; Hadjmohammadi, Mohammad Reza

    2016-12-01

    A sensitive and rapid method based on alcohol-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of fluoxetine in human plasma and urine samples was developed. The effects of six parameters on the extraction recovery were investigated and optimized utilizing Plackett-Burman design and Box-Benken design, respectively. According to the Plackett-Burman design results, the volume of disperser solvent, extraction time, and stirring speed had no effect on the recovery of fluoxetine. The optimized conditions included a mixture of 172 μL of 1-octanol as extraction solvent and 400 μL of methanol as disperser solvent, pH of 11.3 and 0% w/v of salt in the sample solution. Replicating the experiment in optimized condition for five times, gave the average extraction recoveries equal to 90.15%. The detection limit of fluoxetine in human plasma was obtained 3 ng/mL, and the linearity was in the range of 10-1200 ng/mL. The corresponding values for human urine were 4.2 ng/mL with the linearity range from 10 to 2000 ng/mL. Relative standard deviations for intra and inter day extraction of fluoxetine were less than 7% in five measurements. The developed method was successfully applied for the determination of fluoxetine in human plasma and urine samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Human plasma paraoxonase 1 (PON1) arylesterase activity during aging: correlation with susceptibility of LDL oxidation.

    PubMed

    Mehdi, Mohammad Murtaza; Rizvi, Syed Ibrahim

    2012-08-01

    The role of free radicals has long been proposed as a cause for the aging process. Oxidative stress is considered a major factor for altering many physiological processes and enzymatic activities during aging and is also known to play a major role in the development of several age-dependent diseases. Paraoxonase 1 (PON1) is an anti-atherosclerotic enzyme that mainly prevents accumulation of lipoperoxides and inhibits the lipid oxidation in low-density lipoproteins (LDL). This study was undertaken to investigate the antioxidant behavior of PON1 by measuring its arylesterase activity. The susceptibility of LDL for oxidation and the radical scavenging activity of plasma were also measured during aging in humans. Arylesterase activity of PON1 was measured in plasma of human subjects between 20 and 81 years of age of both genders. The susceptibility of LDL for oxidation and radical scavenging activity were measured in plasma. Decrease in plasma arylesterase activity of PON1, increase in susceptibility of LDL for oxidation and decrease in plasma radical scavenging activity were observed as a function of human age. The study provides evidence of a relationship between PON1 activity, LDL oxidation and free radical scavenging activity of plasma. The present results emphasize the dependency of PON1 activity to prevailing oxidative stress during human aging. Our findings assume significance in view of the possible categorization of PON1 as a longevity gene. Copyright © 2012 IMSS. Published by Elsevier Inc. All rights reserved.

  15. Hemocompatible control of sulfobetaine-grafted polypropylene fibrous membranes in human whole blood via plasma-induced surface zwitterionization.

    PubMed

    Chen, Sheng-Han; Chang, Yung; Lee, Kueir-Rarn; Wei, Ta-Chin; Higuchi, Akon; Ho, Feng-Ming; Tsou, Chia-Chun; Ho, Hsin-Tsung; Lai, Juin-Yih

    2012-12-21

    In this work, the hemocompatibility of zwitterionic polypropylene (PP) fibrous membranes with varying grafting coverage of poly(sulfobetaine methacrylate) (PSBMA) via plasma-induced surface polymerization was studied. Charge neutrality of PSBMA-grafted layers on PP membrane surfaces was controlled by the low-pressure and atmospheric plasma treatment in this study. The effects of grafting composition, surface hydrophilicity, and hydration capability on blood compatibility of the membranes were determined. Protein adsorption onto the different PSBMA-grafted PP membranes from human fibrinogen solutions was measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Blood platelet adhesion and plasma clotting time measurements from a recalcified platelet-rich plasma solution were used to determine if platelet activation depends on the charge bias of the grafted PSBMA layer. The charge bias of PSBMA layer deviated from the electrical balance of positively and negatively charged moieties can be well-controlled via atmospheric plasma-induced interfacial zwitterionization and was further tested with human whole blood. The optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and keeps its original blood-inert property of antifouling, anticoagulant, and antithrmbogenic activities when it comes into contact with human blood. This work suggests that the hemocompatible nature of grafted PSBMA polymers by controlling grafting quality via atmospheric plasma treatment gives a great potential in the surface zwitterionization of hydrophobic membranes for use in human whole blood.

  16. Dietary flavanols and procyanidin oligomers from cocoa (Theobroma cacao) inhibit platelet function.

    PubMed

    Murphy, Karen J; Chronopoulos, Andriana K; Singh, Indu; Francis, Maureen A; Moriarty, Helen; Pike, Marilyn J; Turner, Alan H; Mann, Neil J; Sinclair, Andrew J

    2003-06-01

    Flavonoids may be partly responsible for some health benefits, including antiinflammatory action and a decreased tendency for the blood to clot. An acute dose of flavanols and oligomeric procyanidins from cocoa powder inhibits platelet activation and function over 6 h in humans. This study sought to evaluate whether 28 d of supplementation with cocoa flavanols and related procyanidin oligomers would modulate human platelet reactivity and primary hemostasis and reduce oxidative markers in vivo. Thirty-two healthy subjects were assigned to consume active (234 mg cocoa flavanols and procyanidins/d) or placebo (< or = 6 mg cocoa flavanols and procyanidins/d) tablets in a blinded parallel-designed study. Platelet function was determined by measuring platelet aggregation, ATP release, and expression of activation-dependent platelet antigens by using flow cytometry. Plasma was analyzed for oxidation markers and antioxidant status. Plasma concentrations of epicatechin and catechin in the active group increased by 81% and 28%, respectively, during the intervention period. The active group had significantly lower P selectin expression and significantly lower ADP-induced aggregation and collagen-induced aggregation than did the placebo group. Plasma ascorbic acid concentrations were significantly higher in the active than in the placebo group (P < 0.05), whereas plasma oxidation markers and antioxidant status did not change in either group. Cocoa flavanol and procyanidin supplementation for 28 d significantly increased plasma epicatechin and catechin concentrations and significantly decreased platelet function. These data support the results of acute studies that used higher doses of cocoa flavanols and procyanidins.

  17. Supplementation with Brazil nuts and green tea extract regulates targeted biomarkers related to colorectal cancer risk in humans.

    PubMed

    Hu, Ying; McIntosh, Graeme H; Le Leu, Richard K; Somashekar, Roshini; Meng, Xing Q; Gopalsamy, Geetha; Bambaca, Libby; McKinnon, Ross A; Young, Graeme P

    2016-12-01

    Se and green tea have been shown in epidemiological, observational and preclinical studies to be inversely related to the risk of developing colorectal cancer (CRC). However, there are limited studies to evaluate their regulatory effects on genes/proteins that relate to CRC oncogenesis in human subjects, such as selenoproteins, WNT signalling pathway, inflammation and methylation. This study examined the effects of supplementation of Se using Brazil nuts and green tea extract (GTE) capsules, alone and in combination, on targeted biomarkers. In total, thirty-two volunteers (>50 years of age) with plasma Se≤1·36 µmol/l were randomised to one of three treatment groups: nine to Se (approximately 48 µg/d) as six Brazil nuts, eleven to four GTE capsules (800 mg (-)-epigallocatechin-3-gallate) and twelve to a combination of Brazil nuts and GTE. Blood and rectal biopsies were obtained before and after each intervention. Plasma Se levels, rectal selenoprotein P (SePP) and β-catenin mRNA increased significantly in subjects consuming Brazil nuts alone or in combination, whereas rectal DNA methyltransferase (DNMT1) and NF-κB mRNA were reduced significantly in subjects consuming GTE alone or in combination. None of the interventions significantly affected rectal acetylated histone H3 or Ki-67 expression at the protein level or plasma C-reactive protein. Effects of the combination of Brazil nuts and GTE did not differ from what would be expected from either agent alone. In conclusion, supplementation of Brazil nuts and/or GTE regulates targeted biomarkers related to CRC oncogenesis, specifically genes associated with selenoproteins (SePP), WNT signalling (β-catenin), inflammation (NF-κB) and methylation (DNMT1). Their combination does not appear to provide additional effects compared with either agent alone.

  18. 21 CFR 640.32 - Collection of source material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.32 Collection of source... blood is intended for Plasma, Fresh Frozen Plasma, and Liquid Plasma, until the plasma is removed, the..., Center for Biologics Evaluations and Research. Whole blood intended for Platelet Rich Plasma must be...

  19. 21 CFR 640.32 - Collection of source material.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.32 Collection of source... blood is intended for Plasma, Fresh Frozen Plasma, and Liquid Plasma, until the plasma is removed, the..., Center for Biologics Evaluations and Research. Whole blood intended for Platelet Rich Plasma must be...

  20. 21 CFR 640.32 - Collection of source material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.32 Collection of source... blood is intended for Plasma, Fresh Frozen Plasma, and Liquid Plasma, until the plasma is removed, the..., Center for Biologics Evaluations and Research. Whole blood intended for Platelet Rich Plasma must be...

  1. 21 CFR 640.32 - Collection of source material.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.32 Collection of source... blood is intended for Plasma, Fresh Frozen Plasma, and Liquid Plasma, until the plasma is removed, the..., Center for Biologics Evaluations and Research. Whole blood intended for Platelet Rich Plasma must be...

  2. 21 CFR 640.32 - Collection of source material.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.32 Collection of source... blood is intended for Plasma, Fresh Frozen Plasma, and Liquid Plasma, until the plasma is removed, the..., Center for Biologics Evaluations and Research. Whole blood intended for Platelet Rich Plasma must be...

  3. Determination of alpidem, an imidazopyridine anxiolytic, and its metabolites by column-switching high-performance liquid chromatography with fluorescence detection.

    PubMed

    Flaminio, L; Ripamonti, M; Ascalone, V

    1994-05-13

    Alpidem, 6-chloro-2-(4-chlorophenyl)-N,N-dipropylimidazo[1,2-a]pyridine- 3-acetamide, is an anxiolytic imidazopyridine that undergoes a first-pass elimination after oral administration to humans; it is actively metabolized and three circulating metabolites have been identified in plasma due to N-dealkylation, oxidation or a combination of both processes. For the determination of the unchanged drug and its metabolites in human plasma, a column-switching HPLC method was developed. The method, based on solid-phase extraction (performed on-line), involves the automatic injection of plasma samples (200 microliters) on to a precolumn filled with C18 material, clean-up of the sample with water in order to remove protein and salts and transfer of the analytes to the analytical column (after valve switching) by means of the mobile phase. All the processes were performed in the presence of an internal standard, a compound chemically related to alpidem. During the analytical chromatography, the precolumn was flushed with different solvents and after regeneration with water, it was ready for further injections. The analytical column was a C8 type and the mobile phase was acetonitrile-methanol-phosphate buffer solution (45:15:45, v/v/v) at a flow-rate of 1.5 ml min-1. The column was connected to a fluorimetric detector operating at excitation and emission wavelengths of 255 and 423 nm, respectively. The limits of quantitation of alpidem and three metabolites were 2.5 and 1.5 ng ml-1, respectively, in human plasma.

  4. Determination of methylglyoxal in human blood plasma using fluorescence high performance liquid chromatography after derivatization with 1,2-diamino-4,5-methylenedioxybenzene.

    PubMed

    Ogasawara, Yuki; Tanaka, Ryo; Koike, Shin; Horiuchi, Yasue; Miyashita, Mitsuhiro; Arai, Makoto

    2016-09-01

    Methylglyoxal (MG) is a highly reactive dicarbonyl compound that promotes the non-enzymatic glycation of proteins to yield irreversible advanced glycated end products, leading to the cross-linking or degradation of proteins. The physiological relevance of MG currently remains unclear because its metabolic behavior has not yet been elucidated in detail. Although several labeling methods that require a HPLC system have been developed and used to measure MG, a standard method to analyze the content of MG in biological samples has not been established. We herein present a practical method based on HPLC with fluorescence detection to measure low MG levels. MG concentrations were also measured in human blood plasma using the present method in order to demonstrate its utility. A calibration curve was produced using freshly purified MG at concentrations ranging between 0.05 and 1.0μM. The intra-day and inter-day relative standard diviations of the method were 2.55% and 4.03%, respectively. The limit of detection and limit of quantification were 60fmol and 200fmol, respectively for MG with a 10-μl injection volume of the derivatized sample solution. When the optimized method was applied to human plasma, the resulting concentrations of MG in the plasma of healthy subjects (n=23) ranged between 0.024 and 0.258μM (mean±SD=0.098±0.066). Thus, the method developed herein is simple, sensitive, and easy to operate for the measurement of MG in biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Measurement of Human Blood and Plasma Volumes

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Szalkay, H. G. H.

    1987-01-01

    Report reviews techniques for measuring blood-plasma volume in humans. Common technique of using radioactive iodine isotope to label plasma albumin involves unwarranted risks from low-level radiation. Report emphasizes techniques using Evans-blue-dye (T-1824) labeling of albumin, hematocrit or hemoglobin/hematocrit measurements, or blood densitometry. In Evans-blue-dye technique, plasma volume determined from decrease in dye concentration occurring after small amount of dye solution injected into circulatory system. Subjection of Evans blue dye to test for carcinogenicity gave negative results.

  6. An 11 cm long atmospheric pressure cold plasma plume for applications of plasma medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Xinpei; Jiang Zhonghe; Xiong Qing

    2008-02-25

    In this letter, a room temperature atmospheric pressure plasma jet device is reported. The high voltage electrode of the device is covered by a quartz tube with one end closed. The device, which is driven by a kilohertz ac power supply, is capable of generating a plasma plume up to 11 cm long in the surrounding room air. The rotational and vibrational temperatures of the plasma plume are 300 and 2300 K, respectively. A simple electrical model shows that, when the plasma plume is contacted with a human, the voltage drop on the human is less than 66 V formore » applied voltage of 5 kV (rms)« less

  7. Prevention of obesity relatred metabolic diseases by processed foods containing soluble dietary fibers and flavonoids (abstract)

    USDA-ARS?s Scientific Manuscript database

    Asians and other non-caucasians are generally more susceptible to obesity related chronic diseases such as type 2 diabetes and cardiovascular disease. Viscous soluble dietary fibers such as cereal beta-glucans and psyllium reduce plasma cholesterol and postprandial glycemia in humans. We have stud...

  8. S-Adenosylmethionine-dependent protein methylation Is required for expression of selenoprotein P and gluconeogenic enzymes in HepG2 human hepatocytes

    USDA-ARS?s Scientific Manuscript database

    Cellular methylation processes enable expression of gluconeogenic enzymes and metabolism of the nutrient selenium (Se). Se status may relate to type-II diabetes and plasma levels of selenoprotein P (SEPP1) are positively correlated with insulin resistance. Increased expression of gluconeogenic enzym...

  9. Cloning, characterization and comparative analysis of pig plasma apolipoprotein A-IV.

    PubMed

    Navarro, María A; Acín, Sergio; Iturralde, María; Calleja, Lucía; Carnicer, Ricardo; Guzmán-García, Mario A; González-Ramón, Nieves; Mata, Pedro; Isabel, Beatriz; López-Bote, Clemente J; Lampreave, Fermín; Piñeiro, Andrés; Osada, Jesús

    2004-01-21

    Pig apolipoprotein (apo) A-IV cDNA was cloned, characterized and compared to the human ortholog. Mature porcine apo A-IV consists of 362 amino acids and displays a 75.6% sequence identity with human protein. Pig apo A-IV is the smallest reported mammalian apo A-IV because it lacks the repeated motifs of glutamine and glutamic acid at the carboxyl terminus. A phylogenic tree of apo A-IV mammalian proteins reveals that porcine apo A-IV is more closely related to humans and primates than to rodents. This protein is highly hydrophobic and is mainly associated with lipoproteins.

  10. Mastication as a Stress-Coping Behavior

    PubMed Central

    Iinuma, Mitsuo

    2015-01-01

    Exposure to chronic stress induces various physical and mental effects that may ultimately lead to disease. Stress-related disease has become a global health problem. Mastication (chewing) is an effective behavior for coping with stress, likely due to the alterations chewing causes in the activity of the hypothalamic-pituitary-adrenal axis and autonomic nervous system. Mastication under stressful conditions attenuates stress-induced increases in plasma corticosterone and catecholamines, as well as the expression of stress-related substances, such as neurotrophic factors and nitric oxide. Further, chewing reduces stress-induced changes in central nervous system morphology, especially in the hippocampus and hypothalamus. In rodents, chewing or biting on wooden sticks during exposure to various stressors reduces stress-induced gastric ulcer formation and attenuates spatial cognitive dysfunction, anxiety-like behavior, and bone loss. In humans, some studies demonstrate that chewing gum during exposure to stress decreases plasma and salivary cortisol levels and reduces mental stress, although other studies report no such effect. Here, we discuss the neuronal mechanisms that underline the interactions between masticatory function and stress-coping behaviors in animals and humans. PMID:26090453

  11. Bioavailability of metronidazole in rabbits after administration of a rectal suppository.

    PubMed

    Ofoefule, Sabinus I; Ibezim, Emmanuel C; Esimone, Okechukwu C; Pepple, Miriam N; Njoku, Chinedu N; Orisakwe, Ebere O

    2004-01-01

    The bioavailability of metronidazole in rabbits was studied using plasma concentration measurements after the administration of the drug in a hydrophilic (glycerogelatin) suppository form. The peak in the plasma concentration time curve occurred about 1 hour after administration, indicating that the rate of absorption is fast and equivalent to that observed in humans after oral administration. There was rapid elimination of the drug, as indicated by a relatively high elimination rate constant and low plasma half-life. The in vitro dissolution profile of the suppositories further confirms rapid absorption of the drug from the suppositories in the rectum. The presence of Tween 80 enhanced the in vitro release of metronidazole, but the presence of a hydrogenated vegetable oil lubricant (Lubritab) caused retardation in the drug release from the suppositories.

  12. Radioimmunoassay and chromatographic similarity of circulating endogenous gonadotropin releasing hormone and hypothalamic extracts in man. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mortimer, C.H.; McNeilly, A.S.; Rees, L.H.

    1976-10-01

    A highly sensitive radioimmunoassay for the gonadotropin releasing hormone has been developed in order to study its physiological importance in man. In view of the expected low concentrations in peripheral blood, large volumes of human plasma were extracted by two different methods and the characteristics of the radioimmunoassayable material compared with those of synthetic decapeptide and extracts of human hypothalami. The results indicate that radioimmunoassayable gonadotropin releasing hormone is present in some human plasmas but the plasma concentrations are less than 2.5 pg/ml. Peripheral levels were more consistently measurable in women at midcycle and after the menopause. The hormone wasmore » undetectable in the plasma of normal men, human cerebrospinal fluid, and fetal cerebral tissue, but was present in fetal hypothalami.« less

  13. SDS-binding assay based on tyrosine fluorescence as a tool to determine binding properties of human serum albumin in blood plasma

    NASA Astrophysics Data System (ADS)

    Zhdanova, Nadezda; Shirshin, Evgeny; Fadeev, Victor; Priezzhev, Alexander

    2016-04-01

    Among all plasma proteins human serum albumin (HSA) is the most studied one as it is the main transport protein and can bind a wide variety of ligands especially fatty acids (FAs). The concentration of FAs bound to HSA in human blood plasma differs by three times under abnormal conditions (fasting, physical exercises or in case of social important diseases). In the present study a surfactant sodium dodecyl sulfate (SDS) was used to simulate FAs binding to HSA. It was shown that the increase of Tyr fluorescence of human blood plasma due to SDS addition can be completely explained by HSA-SDS complex formation. Binding parameters of SDS-HSA complex (average number of sites and apparent constant of complex formation) were determined from titration curves based on tyrosine (Tyr) fluorescence.

  14. Fourth Annual Workshop on Space Operations Applications and Research (SOAR 90)

    NASA Technical Reports Server (NTRS)

    Savely, Robert T. (Editor)

    1991-01-01

    The papers from the symposium are presented. Emphasis is placed on human factors engineering and space environment interactions. The technical areas covered in the human factors section include: satellite monitoring and control, man-computer interfaces, expert systems, AI/robotics interfaces, crew system dynamics, and display devices. The space environment interactions section presents the following topics: space plasma interaction, spacecraft contamination, space debris, and atomic oxygen interaction with materials. Some of the above topics are discussed in relation to the space station and space shuttle.

  15. Targeting the Human Complement Membrane Attack Complex to Selectively Kill Prostate Cancer Cells

    DTIC Science & Technology

    2013-10-01

    prostate cancer cells in vitro . Evaluate CD59 expression in human prostate cancer microarrays. Aim 4: Evaluate toxicity and efficacy of the lead PAC5...fragment in vitro . Since PSA is the major chymotrypsin-like serine protease in the seminal plasma and prostatic fluid, we hypothesized that PSA was...that the evolution -related complement protein C5, but not C4, is a substrate of PSA as well. *Department of Pharmacology and Molecular Sciences, The

  16. The risk of transmitting prion disease by blood or plasma products.

    PubMed

    Knight, Richard

    2010-12-01

    Various experimental studies have shown infectivity in blood in relation to bovine spongiform encephalitis (BSE) and variant Creutzfeldt-Jakob disease (vCJD). Human to human transmission vCJD infection has been reported via transfusion of non-leukocyte-reduced red cells and, probably, via factor VIII concentrates. A number of precautionary measures are in place but uncertainties remain, especially concerning the number of BSE-infected people in the population. Additional measures such as prion filtration need consideration. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Protein tyrosine adduct in humans self-poisoned by chlorpyrifos

    PubMed Central

    Li, Bin; Eyer, Peter; Eddleston, Michael; Jiang, Wei; Schopfer, Lawrence M.; Lockridge, Oksana

    2013-01-01

    Studies of human cases of self-inflicted poisoning suggest that chlorpyrifos oxon reacts not only with acetylcholinesterase and butyrylcholinesterase but also with other blood proteins. A favored candidate is albumin because in vitro and animal studies have identified tyrosine 411 of albumin as a site covalently modified by organophosphorus poisons. Our goal was to test this proposal in humans by determining whether plasma from humans poisoned by chlorpyrifos has adducts on tyrosine. Plasma samples from 5 self-poisoned humans were drawn at various time intervals after ingestion of chlorpyrifos for a total of 34 samples. All 34 samples were analyzed for plasma levels of chlorpyrifos and chlorpyrifos oxon (CPO) as a function of time post-ingestion. Eleven samples were analyzed for the presence of diethoxyphosphorylated tyrosine by mass spectrometry. Six samples yielded diethoxyphosphorylated tyrosine in pronase digests. Blood collected as late as 5 days after chlorpyrifos ingestion was positive for CPO-tyrosine, consistent with the 20-day half-life of albumin. High plasma CPO levels did not predict detectable levels of CPO-tyrosine. CPO-tyrosine was identified in pralidoxime treated patients as well as in patients not treated with pralidoxime, indicating that pralidoxime does not reverse CPO binding to tyrosine in humans. Plasma butyrylcholinesterase was a more sensitive biomarker of exposure than adducts on tyrosine. In conclusion, chlorpyrifos oxon makes a stable covalent adduct on the tyrosine residue of blood proteins in humans who ingested chlorpyrifos. PMID:23566956

  18. A single-center prospective study on the safety of plasma exchange procedures using a double-viral-inactivated and prion-reduced solvent/detergent fresh-frozen plasma as the replacement fluid in the treatment of thrombotic microangiopathy.

    PubMed

    Vendramin, Chiara; McGuckin, Siobhan; Alwan, Ferras; Westwood, John-Paul; Thomas, Mari; Scully, Marie

    2017-01-01

    Patients presenting with acute episodes of thrombotic microangiopathies (TMAs) require urgent access to plasma exchange (PEX). OctaplasLG, a solvent/detergent fresh-frozen plasma product that has undergone viral inactivation and prion reduction step, has been used in our institution since 2013, replacing Octaplas. We prospectively reviewed 981 PEX procedures where OctaplasLG was the replacement fluid in 90 patients admitted acutely with a TMA presentation within our institution from January 1, 2013, to December 31, 2015. We recorded citrate toxicities, plasma reactions, viral transfer, complications related to central venous catheter, and venous thrombotic events (VTEs). Citrate toxicities were 5.4%, plasma reactions were 2%, and all were classified as Grade 1 or 2. VTE had an incidence of 12.2%, although 50% of the episodes occurred in early remission when patients were not receiving PEX. No line insertions complications were recorded. Line-associated infections were 2.2%. Hepatitis B and C serology and human immunodeficiency virus (HIV) were checked on admission. There were four patients who may have had passive transient transfer of hepatitis B antibodies from pooled plasma. No hepatitis C or HIV viral transfer was documented after treatment and no seroconversion was detected after treatment. Our data have demonstrated that the incidence of complications during PEX is low and using OctaplasLG is comparable to the low incidence of reactions. No cases of anaphylaxis, transfusion-related acute lung injury, or fatal plasma reactions were seen. There was no evidence of viral transmission or seroconversion after treatment. © 2016 AABB.

  19. Cerebrospinal fluid and plasma C-reactive protein and aggression in personality-disordered subjects: a pilot study.

    PubMed

    Coccaro, Emil F; Lee, Royce; Coussons-Read, Mary

    2015-02-01

    C-reactive protein (CRP), in the plasma, serves as a marker of systemic inflammation and has been shown to correlate with history of actual aggressive behavior, and as a personality trait of aggressive tendency, in human subjects. This pilot study was conducted to determine if plasma CRP levels are correlated with cerebrospinal fluid levels (CSF CRP) and if CSF CRP also correlates with aggression. If so, this would suggest a role for central inflammatory processes in human aggression. Both plasma and basal lumbar CSF samples were obtained from 17 subjects with DSM-5 personality disorder and assayed for CRP. Plasma and CSF CRP levels were correlated (r = 0.65, p = 0.005) and each correlated with aggression (Plasma: r = 0.53, p = 0.029; CSF: r = 0.84, p < 0.001). When considered simultaneously, CSF CRP, but not plasma CRP, uniquely correlated with aggression. No relationship was seen with other measures of psychopathology. These data suggest a positive relationship between central nervous system CRP and aggression in humans.

  20. Serum-converted platelet lysate can substitute for fetal bovine serum in human mesenchymal stromal cell cultures.

    PubMed

    Mojica-Henshaw, Mariluz P; Jacobson, Pam; Morris, Julie; Kelley, Linda; Pierce, Jan; Boyer, Michael; Reems, Jo-Anna

    2013-12-01

    Fetal bovine serum (FBS) is commonly used as a serum supplement for culturing human mesenchymal stromal cells (hMSCs). However, human cells grown in FBS, especially for extended periods, risk potential exposure to bovine immunogenic proteins and infectious agents. To address this issue, we investigated the ability of a novel human platelet serum supplement to substitute for FBS in hMSC cultures. Platelet lysate-serum (PL-serum) was converted from platelet lysate-plasma (PL-plasma) that was manufactured from pooled platelet-rich plasma (PRP) apheresis units. Growth factor levels and the number of residual intact platelets in PL-serum and PL-plasma were compared with enzyme-linked immunosorbent assays and flow cytometry, respectively. Proliferation responses of hMSCs cultured in PL-serum, PL-plasma, or FBS were assessed with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, the immunophenotype of harvested hMSCs was evaluated by flow cytometry and tri-lineage differentiation potential was evaluated by assessing adipogenic, osteogenic and chondrogenic development. Selected growth factor levels in PL-serum were not significantly different from PL-plasma (P > 0.05). hMSC cultures supplemented with PL-serum had comparable growth kinetics to PL-plasma, and hMSC yields were consistently greater than with FBS. hMSCs harvested from cultures supplemented with PL-serum, PL-plasma or FBS had similar cell surface phenotypes and maintained tri-lineage differentiation potential. PL-serum, similar to PL-plasma, can substitute for FBS in hMSC cultures. Use of PL-serum, in contrast to PL-plasma, has an added advantage of not requiring addition of a xenogeneic source of heparin, providing a completely xeno-free culture medium. Copyright © 2013 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  1. An initial evaluation of newly proposed biomarker of zinc status in humans - linoleic acid: dihomo-γ-linolenic acid (LA:DGLA) ratio.

    PubMed

    Knez, Marija; Stangoulis, James C R; Zec, Manja; Debeljak-Martacic, Jasmina; Pavlovic, Zoran; Gurinovic, Mirjana; Glibetic, Maria

    2016-10-01

    Zinc is an essential micronutrient for humans with important physiological functions. A sensitive and specific biomarker for assessing Zn status is still needed. The major aim of this study was to examine if the changes in the content of plasma phospholipid LA, DGLA and LA: DGLA ratio can be used to efficiently predict the dietary Zn intake and plasma Zn status of humans. The study was performed on healthy human volunteers, 25-55 years of age. The dietary Zn intake was assessed using 24 h recall questionnaires. Plasma phospholipid fatty acid analysis was done by gas chromatography, and plasma analysis of minerals by atomic absorption spectrometry. Biochemical, anthropometrical and hematological parameters were assessed. No significant relationship was found between the dietary and plasma zinc status (r = 0.07; p = 0.6). There was a statistically significant correlation between DGLA and plasma Zn (r = 0.39, p = 0.00). No relationship was observed between the linoleic acid and plasma Zn, while there was a significant negative correlation between LA: DGLA ratio and plasma Zn status (r = -0.35, p = 0.01). Similarly, there were statistically significant difference in DGLA status (p = 0.004) and LA: DGLA ratio (p = 0.042) between the Zn formed groups. This study is an initial step in evaluating LA: DGLA ratio as a biomarker of Zn status in humans. The results are encouraging as they show that concentration of DGLA is decreased and LA: DGLA ratio increased in people with lower dietary Zn intake. However, additional studies are needed to fully examine the sensitivity of this biomarker. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Prostate Secretory Protein of 94 Amino Acids (PSP94) Binds to Prostatic Acid Phosphatase (PAP) in Human Seminal Plasma

    PubMed Central

    Anklesaria, Jenifer H.; Jagtap, Dhanashree D.; Pathak, Bhakti R.; Kadam, Kaushiki M.; Joseph, Shaini; Mahale, Smita D.

    2013-01-01

    Prostate Secretory Protein of 94 amino acids (PSP94) is one of the major proteins present in the human seminal plasma. Though several functions have been predicted for this protein, its exact role either in sperm function or in prostate pathophysiology has not been clearly defined. Attempts to understand the mechanism of action of PSP94 has led to the search for its probable binding partners. This has resulted in the identification of PSP94 binding proteins in plasma and seminal plasma from human. During the chromatographic separation step of proteins from human seminal plasma by reversed phase HPLC, we had observed that in addition to the main fraction of PSP94, other fractions containing higher molecular weight proteins also showed the presence of detectable amounts of PSP94. This prompted us to hypothesize that PSP94 could be present in the seminal plasma complexed with other protein/s of higher molecular weight. One such fraction containing a major protein of ∼47 kDa, on characterization by mass spectrometric analysis, was identified to be Prostatic Acid Phosphatase (PAP). The ability of PAP present in this fraction to bind to PSP94 was demonstrated by affinity chromatography. Co-immunoprecipitation experiments confirmed the presence of PSP94-PAP complex both in the fraction studied and in the fresh seminal plasma. In silico molecular modeling of the PSP94-PAP complex suggests that β-strands 1 and 6 of PSP94 appear to interact with domain 2 of PAP, while β-strands 7 and 10 with domain 1 of PAP. This is the first report which suggests that PSP94 can bind to PAP and the PAP-bound PSP94 is present in human seminal plasma. PMID:23469287

  3. A study of the effect on human mesenchymal stem cells of an atmospheric pressure plasma source driven by different voltage waveforms

    NASA Astrophysics Data System (ADS)

    Laurita, R.; Alviano, F.; Marchionni, C.; Abruzzo, P. M.; Bolotta, A.; Bonsi, L.; Colombo, V.; Gherardi, M.; Liguori, A.; Ricci, F.; Rossi, M.; Stancampiano, A.; Tazzari, P. L.; Marini, M.

    2016-09-01

    The effect of an atmospheric pressure non-equilibrium plasma on human mesenchymal stem cells was investigated. A dielectric barrier discharge non-equilibrium plasma source driven by two different high-voltage pulsed generators was used and cell survival, senescence, proliferation, and differentiation were evaluated. Cells deprived of the culture medium and treated with nanosecond pulsed plasma showed a higher mortality rate, while higher survival and retention of proliferation were observed in cells treated with microsecond pulsed plasma in the presence of the culture medium. While a few treated cells showed the hallmarks of senescence, unexpected delayed apoptosis ensued in cells exposed to plasma-treated medium. The plasma treatment did not change the expression of OCT4, a marker of mesenchymal stem cell differentiation.

  4. Plasma levels of acylated ghrelin in patients with functional dyspepsia

    PubMed Central

    Kim, Yeon Soo; Lee, Joon Seong; Lee, Tae Hee; Cho, Joo Young; Kim, Jin Oh; Kim, Wan Jung; Kim, Hyun Gun; Jeon, Seong Ran; Jeong, Hoe Su

    2012-01-01

    AIM: To investigate the relationship between plasma acylated ghrelin levels and the pathophysiology of functional dyspepsia. METHODS: Twenty-two female patients with functional dyspepsia and twelve healthy volunteers were recruited for the study. The functional dyspepsia patients were each diagnosed based on the Rome III criteria. Eligible patients completed a questionnaire concerning the severity of 10 symptoms. Plasma acylated ghrelin levels before and after a meal were determined in the study participants using a commercial human acylated enzyme immunoassay kit; electrogastrograms were performed for 50 min before and after a standardized 10-min meal containing 265 kcal. RESULTS: There were no significant differences in plasma acylated ghrelin levels between healthy volunteers and patients with functional dyspepsia. However, in patients with functional dyspepsia, there was a negative correlation between fasting plasma acylated ghrelin levels and the sum score of epigastric pain (r = -0.427, P = 0.047) and a positive correlation between the postprandial/fasting plasma acylated ghrelin ratio and the sum score of early satiety (r = 0.428, P =0.047). Additionally, there was a negative correlation between fasting acylated ghrelin plasma levels and fasting normogastria (%) (r = -0.522, P = 0.013). Interestingly, two functional dyspepsia patients showed paradoxically elevated plasma acylated ghrelin levels after the meal. CONCLUSION: Abnormal plasma acylated ghrelin levels before or after a meal may be related to several of the dyspeptic symptoms seen in patients with functional dyspepsia. PMID:22611317

  5. Radioimmunoassay of human Hageman factor (factor XII). [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saito, H.; Ratnoff, O.D.; Pensky, J.

    A specific, sensitive, and reproducible radioimmunoassay for human Hageman factor (HF, factor XII) has been developed with purified human HF and monospecific rabbit antibody. Precise measurements of HF antigen were possible for concentrations as low as 0.1 percent of that in normal pooled plasma. A good correlation (correlation coefficient = 0.82) existed between the titers of HF measured by clot-promoting assays and radioimmunoassays among 42 normal adults. Confirming earlier studies, HF antigen was absent in Hageman trait plasma, but other congenital deficient plasmas, including those of individuals with Fletcher trait and Fitzgerald trait, contained normal amounts of HF antigen. HFmore » antigen was reduced in the plasmas of patients with disseminated intravascular coagulation or advanced liver cirrhosis, but it was normal in those of patients with chronic renal failure or patients under treatment with warfarin. HF antigen was detected by this assay in plasmas of primates, but not detectable in plasmas of 11 nonprimate mammalian and one avian species.« less

  6. Lack of Association between Human Plasma Oxytocin and Interpersonal Trust in a Prisoner’s Dilemma Paradigm

    PubMed Central

    Christensen, James C.; Shiyanov, Pavel A.; Estepp, Justin R.; Schlager, John J.

    2014-01-01

    Expanding interest in oxytocin, particularly the role of endogenous oxytocin in human social behavior, has created a pressing need for replication of results and verification of assay methods. In this study, we sought to replicate and extend previous results correlating plasma oxytocin with trust and trustworthy behavior. As a necessary first step, the two most commonly used commercial assays were compared in human plasma via the addition of a known quantity of exogenous oxytocin, with and without sample extraction. Plasma sample extraction was found to be critical in obtaining repeatable concentrations of oxytocin. In the subsequent trust experiment, twelve samples in duplicate, from each of 82 participants, were collected over approximately six hours during the performance of a Prisoner’s Dilemma task paradigm that stressed human interpersonal trust. We found no significant relationship between plasma oxytocin concentrations and trusting or trustworthy behavior. In light of these findings, previous published work that used oxytocin immunoassays without sample extraction should be reexamined and future research exploring links between endogenous human oxytocin and trust or social behavior should proceed with careful consideration of methods and appropriate biofluids for analysis. PMID:25549255

  7. Random and independent sampling of endogenous tryptic peptides from normal human EDTA plasma by liquid chromatography micro electrospray ionization and tandem mass spectrometry.

    PubMed

    Dufresne, Jaimie; Florentinus-Mefailoski, Angelique; Ajambo, Juliet; Ferwa, Ammara; Bowden, Peter; Marshall, John

    2017-01-01

    Normal human EDTA plasma samples were collected on ice, processed ice cold, and stored in a freezer at - 80 °C prior to experiments. Plasma test samples from the - 80 °C freezer were thawed on ice or intentionally warmed to room temperature. Protein content was measured by CBBR binding and the release of alcohol soluble amines by the Cd ninhydrin assay. Plasma peptides released over time were collected over C18 for random and independent sampling by liquid chromatography micro electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) and correlated with X!TANDEM. Fully tryptic peptides by X!TANDEM returned a similar set of proteins, but was more computationally efficient, than "no enzyme" correlations. Plasma samples maintained on ice, or ice with a cocktail of protease inhibitors, showed lower background amounts of plasma peptides compared to samples incubated at room temperature. Regression analysis indicated that warming plasma to room temperature, versus ice cold, resulted in a ~ twofold increase in the frequency of peptide identification over hours-days of incubation at room temperature. The type I error rate of the protein identification from the X!TANDEM algorithm combined was estimated to be low compared to a null model of computer generated random MS/MS spectra. The peptides of human plasma were identified and quantified with low error rates by random and independent sampling that revealed 1000s of peptides from hundreds of human plasma proteins from endogenous tryptic peptides.

  8. Plasma Retention and Systemic Kinetics of 90Sr Intramuscularly Injected in Female Nonhuman Primates

    DOE PAGES

    Poudel, Deepesh; Klumpp, John A.; Bertelli, Luiz; ...

    2017-08-01

    Thirteen female Rhesus macaques were intramuscularly injected with 90Sr(NO 3) 2 diluted in sodium citrate solution. The biokinetic data from these animals were compared against the predictions of the NCRP 156 wound models combined with the ICRP systemic models. We observed observed that the activities measured in plasma of these nonhuman primates (NHPs) were consistently lower than those predicted by the default human biokinetic models. The urinary excretion from the NHPs at times immediately after injection was much greater than that in humans. The fecal excretion rates were found to be in relatively better agreement with humans. Similarly, the activitiesmore » retained in the skeleton of the NHPs were lower than that in humans. These differences were attributed to the higher calcium diet of the NHPs (0.03 to 0.12 g/d/kg body weight) compared to that of humans. These observations were consistent with the early animal and human studies that showed the effect of calcium on strontium metabolism, specifically urinary excretion. Strontium is preferentially filtered at a much higher rate in kidneys than calcium because it is less completely bound to protein than is calcium. Furthermore, these differences, along with large inter-animal variability, should be considered when estimating the behavior of Sr in humans from the metabolic data in animals or vice-versa.« less

  9. Plasma Retention and Systemic Kinetics of 90Sr Intramuscularly Injected in Female Nonhuman Primates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poudel, Deepesh; Klumpp, John A.; Bertelli, Luiz

    Thirteen female Rhesus macaques were intramuscularly injected with 90Sr(NO 3) 2 diluted in sodium citrate solution. The biokinetic data from these animals were compared against the predictions of the NCRP 156 wound models combined with the ICRP systemic models. We observed observed that the activities measured in plasma of these nonhuman primates (NHPs) were consistently lower than those predicted by the default human biokinetic models. The urinary excretion from the NHPs at times immediately after injection was much greater than that in humans. The fecal excretion rates were found to be in relatively better agreement with humans. Similarly, the activitiesmore » retained in the skeleton of the NHPs were lower than that in humans. These differences were attributed to the higher calcium diet of the NHPs (0.03 to 0.12 g/d/kg body weight) compared to that of humans. These observations were consistent with the early animal and human studies that showed the effect of calcium on strontium metabolism, specifically urinary excretion. Strontium is preferentially filtered at a much higher rate in kidneys than calcium because it is less completely bound to protein than is calcium. Furthermore, these differences, along with large inter-animal variability, should be considered when estimating the behavior of Sr in humans from the metabolic data in animals or vice-versa.« less

  10. High Levels of Exosomes Expressing CD63 and Caveolin-1 in Plasma of Melanoma Patients

    PubMed Central

    Logozzi, Mariantonia; De Milito, Angelo; Lugini, Luana; Borghi, Martina; Calabrò, Luana; Spada, Massimo; Perdicchio, Maurizio; Marino, Maria Lucia; Federici, Cristina; Iessi, Elisabetta; Brambilla, Daria; Venturi, Giulietta; Lozupone, Francesco; Santinami, Mario; Huber, Veronica; Maio, Michele; Rivoltini, Licia; Fais, Stefano

    2009-01-01

    Background Metastatic melanoma is an untreatable cancer lacking reliable and non-invasive markers of disease progression. Exosomes are small vesicles secreted by normal as well as tumor cells. Human tumor-derived exosomes are involved in malignant progression and we evaluated the presence of exosomes in plasma of melanoma patients as a potential tool for cancer screening and follow-up. Methodology/Principal Findings We designed an in-house sandwich ELISA (Exotest) to capture and quantify exosomes in plasma based on expression of housekeeping proteins (CD63 and Rab-5b) and a tumor-associated marker (caveolin-1). Western blot and flow cytometry analysis of exosomes were used to confirm the Exotest-based findings. The Exotest allowed sensitive detection and quantification of exosomes purified from human tumor cell culture supernatants and plasma from SCID mice engrafted with human melanoma. Plasma levels of exosomes in melanoma-engrafted SCID mice correlated to tumor size. We evaluated the levels of plasma exosomes expressing CD63 and caveolin-1 in melanoma patients (n = 90) and healthy donors (n = 58). Consistently, plasma exosomes expressing CD63 (504±315) or caveolin-1 (619±310) were significantly increased in melanoma patients as compared to healthy donors (223±125 and 228±102, respectively). While the Exotest for CD63+ plasma exosomes had limited sensitivity (43%) the Exotest for detection of caveolin-1+ plasma exosomes showed a higher sensitivity (68%). Moreover, caveolin-1+ plasma exosomes were significantly increased with respect to CD63+ exosomes in the patients group. Conclusions/Significance We describe a new non-invasive assay allowing detection and quantification of human exosomes in plasma of melanoma patients. Our results suggest that the Exotest for detection of plasma exosomes carrying tumor-associated antigens may represent a novel tool for clinical management of cancer patients. PMID:19381331

  11. Variability of oxygen radical absorbance capacity (ORAC) in different animal species.

    PubMed

    Ninfali, P; Aluigi, G

    1998-11-01

    The oxygen radical absorbance capacity (ORAC) was measured both in whole (ORAC-T) and deproteinized (ORAC-AS) plasma samples of human, pig, cow, rabbit, dog, cat, sheep, horse, dolphin, turkey, guinea-hen and chicken. In the 12 species, ORAC-T data, expressed as micromoles of peroxyl radicals trapped by 11 of sample, were found scattered between 8,600 and 23,000 micromol/l. The species with the highest ORAC-T values were cat among mammals and chicken among avies. ORAC-AS values ranged between 600 and 2000 micromol/l, with the highest values found in dolphin and sheep among mammals, while chicken was first among avies. In the 12 species, the relative contribution of ORAC-AS in relation to ORAC-T ranged from 5% to 20%. Protein SH-groups and uric acid were measured in plasma of all species, but no significant correlation was found between thiols and ORAC-T values or between uric acid and ORAC-AS values. Our results show that: (1) the ORAC method is reproducible and sensitive enough to be used in the comparison of the peroxyl-radical absorbance capacity of protein and non-protein plasma components in different animal species; (2) both in mammals and in avies, there is a deep intra-class heterogeneity of ORAC-T and ORAC-AS values; (3) by considering most species, plasma proteins and lipoproteins account for about 85-90% of the overall peroxyl-radical trapping capacity. In the dolphin only, the protein contribution decreases to 80%; (4) uric acid accounts for about one-half of the ORAC-AS value in human, guinea-hen and for about one-third in chicken, while it provides a very limited contribution in other species. We conclude that species with the highest ORAC-T, like cat and chicken, or with the highest ORAC-AS, like dolphin, are interesting models to study the reasons of such a marked antioxidant defense in the plasma.

  12. Comparative chromatography-mass spectrometry studies on the antiretroviral drug nevirapine-analytical performance characteristics in human plasma determination.

    PubMed

    Sichilongo, Kwenga; Chinyama, Mompati; Massele, Amos; Vento, Sandro

    2014-01-15

    A contrast between the analytical performance characteristics using gas chromatography-mass spectrometry (GC-MS) liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-ultraviolet (LC-UV) detection for the determination of the antiretroviral drug (ARV) nevirapine (NVP) in fortified human plasma after QuEChERS extraction has been made. Analytical performance characteristics, i.e. linearities, instrument detection limits (IDLs), limits of quantitation (LOQs), method detection limits (MDLs), % mean recoveries and the corresponding relative standard deviations (%RSDs) were estimated using techniques above. Using GC-MS, the correlation coefficients (r(2)) were ≥0.990, which were deemed acceptable linearities. The MDLs ranged between 11.1-29.8μg/L and 13.7-36.0μg/L using helium and hydrogen carrier gases respectively. The LOQs ranged between 16.5-66.7μg/L and 28.4-98.7μg/L using helium and hydrogen carrier gases respectively with a % mean recovery of 83% and %RSD of 4.6%. Using LC-MS and LC-UV, the correlation coefficients (r(2)) were ≥0.990. The MDLs were ranged between 3.14 and 47.1μg/L. The LOQs ranged between 2.85 and 90.0μg/L respectively. The MDLs using GC-MS, LC-MS and LC-UV were below the therapeutic range for NVP in human plasma is considered to be between 2300μg/L (Cmin) and 8000μg/L (Cmax). This study also demonstrated that helium can be substituted with hydrogen which is relatively cheaper and easily obtainable even by use of a generator. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Tendinopathies and platelet-rich plasma (PRP): from pre-clinical experiments to therapeutic use

    PubMed Central

    Kaux, Jean-François; Drion, Pierre; Croisier, Jean-Louis; Crielaard, Jean-Michel

    2015-01-01

    Objectives: The restorative properties of platelets, through the local release of growth factors, are used in various medical areas. This article reviews fundamental and clinical research relating to platelet-rich plasma applied to tendinous lesions. Materials and method: Articles in French and English, published between 1 January 2012 and 31 December 2014. dealing with PRP and tendons were searched for using the Medline and Scopus data bases. Results: Forty-seven articles were identified which addressed pre-clinical and clinical studies: 27 relating to in vitro and in vivo animal studies and 20 relating to human studies. Of these, five addressed lateral epicondylitis, two addressed rotator cuff tendinopathies, ten dealt with patellar tendinopathies and three looked at Achilles tendinopathies. Conclusions: The majority of pre-clinical studies show that PRP stimulates the tendon’s healing process. However, clinical series remain more controversial and level 1, controlled, randomised studies are still needed. PMID:26195890

  14. Endogenous pyrogen activity in human plasma after exercise.

    PubMed

    Cannon, J G; Kluger, M J

    1983-05-06

    Plasma obtained from human subjects after exercise and injected intraperitoneally into rats elevated rat rectal temperature and depressed plasma iron and zinc concentrations. The pyrogenic component was heat-denaturable and had an apparent molecular weight of 14,000 daltons. Human mononuclear leukocytes obtained after exercise and incubated in vitro released a factor into the medium that also elevated body temperature in rats and reduced trace metal concentrations. These results suggest that endogenous pyrogen, a protein mediator of fever and trace metal metabolism during infection, is released during exercise.

  15. Non-polar lipids accumulate during storage of transfusion products and do not contribute to the onset of transfusion-related acute lung injury.

    PubMed

    Peters, A L; Vervaart, M A T; van Bruggen, R; de Korte, D; Nieuwland, R; Kulik, W; Vlaar, A P J

    2017-01-01

    The accumulation of non-polar lipids arachidonic acid, 5-hydroxyeicosatetraenoic acid (HETE), 12-HETE and 15-HETE during storage of transfusion products may play a role in the onset of transfusion-related acute lung injury (TRALI), a syndrome of respiratory distress after transfusion. We investigated non-polar lipid accumulation in red blood cells (RBCs) stored for 42 days, plasma stored for 7 days at either 4 or 20°C and platelet (PLT) transfusion products stored for 7 days. Furthermore, we investigated whether transfusion of RBCs with increased levels of non-polar lipids induces TRALI in a 'two-hit' human volunteer model. All products were produced following Dutch Blood Bank protocols and are according to European standards. Non-polar lipids were measured with high-performance liquid chromotography followed by mass spectrometry. All non-polar lipids increased in RBCs after 21 days of storage compared to baseline. The non-polar lipid concentration in plasma increased significantly, and the increase was even more pronounced in products stored at 20°C. In platelets, baseline levels of 5-HETE and 15-HETE were higher than in RBCs or plasma. However, the non-polar lipids did not change significantly during storage of PLT products. Infusion of RBCs with increased levels of non-polar lipids did not induce TRALI in LPS-primed human volunteers. We conclude that non-polar lipids accumulate in RBC and plasma transfusion products and that accumulation is temperature dependent. Accumulation of non-polar lipids does not appear to explain the onset of TRALI (Dutch Trial Register - NTR4455). © 2016 International Society of Blood Transfusion.

  16. Interorgan handling of fibroblast growth factor-23 in humans.

    PubMed

    Verzola, Daniela; Ansaldo, Francesca; Milanesi, Samantha; Parodi, Emanuele Luigi; Rosa, Gian Marco; Sofia, Antonella; Bonanni, Alice; Viazzi, Francesca; Balbi, Manrico; Garibotto, Giacomo

    2017-02-01

    Fibroblast growth factor-23 (FGF-23) accumulates in blood of patients with chronic kidney disease (CKD) and is associated both with cardiovascular complications and disease progression. However, our knowledge of the sites and mechanisms that regulate plasma FGF-23 is still incomplete. We measured plasma intact FGF-23 across the kidney, splanchnic organs, and lung in 11 patients [estimated glomerular filtration rate (eGFR) 60 ± 6 ml/min] during elective diagnostic cardiac catheterizations. In these patients FGF-23 was removed by the kidney, with a fractional extraction (FE) of ∼22%. The FE of FGF-23 across the kidney was similar to that of creatinine (∼17%, P = NS). In addition, the FGF-23 FE by the kidney was significantly directly related to eGFR (r = 0.709 P = 0.018) and to kidney creatinine FE (r = 0.736 P = 0.013) but only as a trend to plasma phosphate levels (r = 0.55, P = 0.18). There was no difference in FGF-23 levels in blood perfusing splanchnic organs and cardiopulmonary bed. However, the arterial-venous difference of FGF-23 across the lung was directly related to FGF-23 pulmonary artery levels, suggesting that the lung, and possibly the heart, participate in the homeostasis of plasma FGF-23 when its systemic levels are increased. Our data show that the human kidney is the only site for FGF-23 removal from blood and suggest that FGF-23 is predominantly removed by glomerular filtration. The kidney ability to remove FGF-23 from the circulation likely accounts for the early increase in blood of FGF-23 in patients with CKD. Copyright © 2017 the American Physiological Society.

  17. Plasma pharmacokinetics of catechin metabolite 4'-O-Me-EGC in healthy humans.

    PubMed

    Renouf, Mathieu; Redeuil, Karine; Longet, Karin; Marmet, Cynthia; Dionisi, Fabiola; Kussmann, Martin; Williamson, Gary; Nagy, Kornél

    2011-10-01

    Tea is an infusion of the leaves of the Camellia sinensis plant and is the most widely consumed beverage in the world after water. Green tea contains significant amounts of polyphenol catechins and represents a promising dietary component to maintain health and well-being. Epidemiological studies indicate that polyphenol intake may have potential health benefits, such as, reducing the incidence of coronary heart disease, diabetes and cancer. While bioavailability of green tea bioactives is fairly well understood, some gaps still remain to be filled, especially the identification and quantification of conjugated metabolites in plasma, such as, sulphated, glucuronidated or methylated compounds. In the present study, we aimed to quantify the appearance of green tea catechins in plasma with particular emphasis on their methylated forms. After feeding 400 mL of green tea, 1.25% infusion to 9 healthy subjects, we found significant amounts of EC, EGC and EGCg in plasma as expected. EGC was the most bioavailable catechin, and its methylated form (4'-O-Me-EGC) was also present in quantifiable amounts. Its kinetics followed that of its parent compound. However, the relative amount of the methylated form of EGC was lower than that of the parent compound, an important aspect which, in the literature, has been controversial so far. The quantitative results presented in our study were confirmed by co-chromatography and accurate mass analysis of the respective standards. We show that the relative abundance of 4'-O-Me-EGC is ~40% compared to the parent EGC. 4'-O-Me-EGC is an important metabolite derived from catechin metabolism. Its presence in significant amounts should not be overlooked when assessing human bioavailability of green tea.

  18. Comparison of proteomic profiles of serum, plasma, and modified media supplements used for cell culture and expansion

    PubMed Central

    Ayache, Saleh; Panelli, Monica C; Byrne, Karen M; Slezak, Stefanie; Leitman, Susan F; Marincola, Francesco M; Stroncek, David F

    2006-01-01

    Background The culture and expansion of human cells for clinical use requires the presence of human serum or plasma in culture media. Although these supplements have been extensively characterized in their chemical composition, only recently it has been possible to provide by high throughput protein analysis, a comprehensive profile of the soluble factors contributing to cell survival. This study analyzed and compared the presence of 100 proteins including chemokines, cytokines and soluble factors in six different types of media supplements: serum, plasma, recalcified plasma, heat inactivated serum, heat inactivated plasma and heat inactivated recalcified plasma. Methods Serum, plasma, recalcified plasma, and heat inactivated supplements were prepared from ten healthy subjects. The levels of 100 soluble factors were measured in each sample using a multiplexed ELISA assay and compared by Eisen hierarchical clustering analysis. Results A comparison of serum and plasma levels of soluble factors found that 2 were greater in plasma but 18 factors were greater in serum including 11 chemokines. The levels of only four factors differed between recalcified plasma and plasma. Heat inactivation had the greatest effect on soluble factors. Supervised Eisen hierarchical clustering indicated that the differences between heat inactivated supplements and those that were not were greater than the differences within these two groups. The levels of 36 factors differed between heat inactivated plasma and plasma. Thirty one of these factors had a lower concentration in heat inactivated plasma including 12 chemokines, 4 growth factors, 4 matrix metalloproteases, and 3 adhesion molecules. Heat inactivated decalcified plasma is often used in place of heat inactivated serum and the levels of 19 soluble factors differed between these two supplements. Conclusion Our report provides a comprehensive protein profile of serum, plasma recalcified plasma, and heat inactivated supplements. This profile represents a qualitative and quantitative database that can aid in the selection of the appropriate blood derived supplement for human cell cultures with special requirements. PMID:17020621

  19. Influence of Electromagnetic Fields on Lead Toxicity: A Study of Conformational Changes in Human Blood Proteins

    PubMed Central

    Ansarihadipour, Hadi; Bayatiani, Mohamadreza

    2016-01-01

    Background Electromagnetic fields (EMF) are associated with oxidative stress, which is in turn associated with reactive oxygen species (ROS), anemia, and hypoxia. Objectives This study focused on the synergistic effects of lead ions and EMF on oxidative modifications in hemoglobin (Hb) and plasma proteins. Patients and Methods In this experimental study, the blood samples were obtained from age- and sex-matched healthy subjects at Arak University of Medical Sciences, Arak, Iran. The collected bloods were prepared as 55 samples and then divided into different groups for incubating with 0 to 100 uM of lead ions in 2 mT and 50 Hz of EMF for 120 minutes. The carbonyl group was determined to be an oxidative biomarker in plasma proteins. The ferric reducing ability of plasma (FRAP) was considered to be an antioxidant power of human plasma. The conformational changes in hemoglobin, met-Hb, and hemichrome were considered to be oxidative markers in red blood cells. To predict the factors affecting the oxyHb, the artificial neural network (MLP: 11,2,2,1) in SPSS software was applied. Results The test subjects showed increased concentrations of metHb (1.8 ± 0.19 vs. 1.36 ± 0.25) and hemichrome (6.01 ± 0.57) in relation to the control subjects. The decreased absorbance at 340 nm (0.88 ± 0.09 vs. 1.07 ± 0.08) demonstrated the reduced interaction between the globin chain and the heme ring. The decreased absorbance at 420 nm (Soret band) (2.96 ± 0.13) and the increased absorbance at 630 nm (0.07 ± 0.002 vs. 0.064 ± 0.005) indicated the conversion of oxyHb to metHb, which confirmed the oxidative damage to the erythrocytes. The linear regression analysis showed significant positive correlations between lead concentration and the percentage of plasma carbonyl content (R2 = 0.96), the relation of plasma carbonyl content to Hb absorbance at 630 nm (R2 = 0.97), and the relation of plasma carbonyl content to metHb concentration (R2 = 0.95) after 120 minutes incubation with lead ions in 20 millitesla and 50 hertz EMF. The artificial neural network analysis showed the significant importance of hemichrome, PCO, metHb, and lead concentration to the oxyHb content of erythrocytes. Conclusions Lead contamination in the presence of an EMF exacerbates the oxidative damage to plasma proteins as well as the conformational changes in Hb. An artificial neural network can be used as a predictive tool for the oxidative danger posed to workers in industrial fields, battery manufacturing companies, and power plants. PMID:27651951

  20. High-performance liquid chromatography-electrospray ionization mass spectrometry determination of sodium ferulate in human plasma.

    PubMed

    Yang, Cheng; Tian, Yuan; Zhang, Zunjian; Xu, Fengguo; Chen, Yun

    2007-02-19

    A selective and sensitive high-performance liquid chromatography-electrospray ionization mass spectrometry method has been developed for the determination of sodium ferulate in human plasma. The sample preparation was a liquid-liquid extraction and chromatographic separation was achieved with an Agilent ZORBAX SB-C(18) (3.5 microm, 100 mm x 3.0 mm) column, using a mobile phase of methanol-0.05% acetic acid 40:60 (v/v). Standard curves were linear (r(2)=0.9982) over the concentration range of 0.007-4.63 nM/ml and had acceptable accuracy and precision. The within- and between-batch precisions were within 12% relative standard deviation. The lower limit of quantification (LLOQ) was 0.007 nM/ml. The validated HPLC-ESI-MS method has been used successfully to study sodium ferulate pharmacokinetics, bioavailability and bioequivalence in 20 healthy volunteers.

  1. Isolation of biologically-active exosomes from human plasma.

    PubMed

    Muller, Laurent; Hong, Chang-Sook; Stolz, Donna B; Watkins, Simon C; Whiteside, Theresa L

    2014-09-01

    Effects of exosomes present in human plasma on immune cells have not been examined in detail. Immunological studies with plasma-derived exosomes require their isolation by procedures involving ultracentrifugation. These procedures were largely developed using supernatants of cultured cells. To test biologic activities of plasma-derived exosomes, methods are necessary that ensure adequate recovery of exosome fractions free of contaminating larger vesicles, cell fragments and protein/nucleic acid aggregates. Here, an optimized method for exosome isolation from human plasma/serum specimens of normal controls (NC) or cancer patients and its advantages and pitfalls are described. To remove undesirable plasma-contaminating components, ultrafiltration of differentially-centrifuged plasma/serum followed by size-exclusion chromatography prior to ultracentrifugation facilitated the removal of contaminants. Plasma or serum was equally acceptable as a source of exosomes based on the recovered protein levels (in μg protein/mL plasma) and TEM image quality. Centrifugation on sucrose density gradients led to large exosome losses. Fresh plasma was the best source of morphologically-intact exosomes, while the use of frozen/thawed plasma decreased exosome purity but not their biologic activity. Treatments of frozen plasma with DNAse, RNAse or hyaluronidase did not improve exosome purity and are not recommended. Cancer patients' plasma consistently yielded more isolated exosomes than did NCs' plasma. Cancer patients' exosomes also mediated higher immune suppression as evidenced by decreased CD69 expression on responder CD4+ T effector cells. Thus, the described procedure yields biologically-active, morphologically-intact exosomes that have reasonably good purity without large protein losses and can be used for immunological, biomarker and other studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Nicotinamide pharmacokinetics in humans: effect of gastric acid inhibition, comparison of rectal vs oral administration and the use of saliva for drug monitoring.

    PubMed Central

    Stratford, M. R.; Dennis, M. F.; Hoskin, P.; Phillips, H.; Hodgkiss, R. J.; Rojas, A.

    1996-01-01

    The effect of inhibiting gastric acid secretion on nicotinamide pharmacokinetics was studied in five volunteers with the intent of reducing the large variations observed previously in the time to and magnitude of peak plasma concentrations. Plasma levels were determined using a standard high-performance liquid chromatography (HPLC) method after an oral dose of 3 g of nicotinamide either alone or preceded by pretreatment with omeprazole. Suppression of gastric acid production had no significant effect on the rate of uptake or on the peak levels achieved. To bypass gastric acidity, the rectal route was also assessed using a suppository in four volunteers and one patient undergoing radiotherapy. Absorption was slow and variable and much lower plasma levels were observed than after oral dosing. Thus, no improvement in the pharmacokinetics of nicotinamide was observed using either of these two approaches. Parallel estimations were made using a novel and non-invasive method for monitoring nicotinamide pharmacokinetics in saliva. A large and variable fraction of the total amount of nicotinamide-related material in saliva was found to be nicotinic acid, a metabolite not normally found in human plasma. This conversion was inhibited by the use of a chlorhexidine mouthwash, indicating that the oral flora was responsible for its production. The time to peak levels of nicotinamide or of nicotinamide plus nicotinic acid in saliva correlated well with that in plasma. However, peak concentrations for nicotinamide alone were significantly lower than in plasma, and very variable, whereas for nicotinamide plus nicotinic acid saliva levels were 20-30% higher, but more consistent. Although there are some practical difficulties in quantitatively handling saliva, the method is very useful for monitoring nicotinamide pharmacokinetics and for assessment of compliance with nicotinamide treatment. PMID:8679452

  3. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  4. Scale-up of a physiologically-based pharmacokinetic model to predict the disposition of monoclonal antibodies in monkeys.

    PubMed

    Glassman, Patrick M; Chen, Yang; Balthasar, Joseph P

    2015-10-01

    Preclinical assessment of monoclonal antibody (mAb) disposition during drug development often includes investigations in non-human primate models. In many cases, mAb exhibit non-linear disposition that relates to mAb-target binding [i.e., target-mediated disposition (TMD)]. The goal of this work was to develop a physiologically-based pharmacokinetic (PBPK) model to predict non-linear mAb disposition in plasma and in tissues in monkeys. Physiological parameters for monkeys were collected from several sources, and plasma data for several mAbs associated with linear pharmacokinetics were digitized from prior literature reports. The digitized data displayed great variability; therefore, parameters describing inter-antibody variability in the rates of pinocytosis and convection were estimated. For prediction of the disposition of individual antibodies, we incorporated tissue concentrations of target proteins, where concentrations were estimated based on categorical immunohistochemistry scores, and with assumed localization of target within the interstitial space of each organ. Kinetics of target-mAb binding and target turnover, in the presence or absence of mAb, were implemented. The model was then employed to predict concentration versus time data, via Monte Carlo simulation, for two mAb that have been shown to exhibit TMD (2F8 and tocilizumab). Model predictions, performed a priori with no parameter fitting, were found to provide good prediction of dose-dependencies in plasma clearance, the areas under plasma concentration versu time curves, and the time-course of plasma concentration data. This PBPK model may find utility in predicting plasma and tissue concentration versus time data and, potentially, the time-course of receptor occupancy (i.e., mAb-target binding) to support the design and interpretation of preclinical pharmacokinetic-pharmacodynamic investigations in non-human primates.

  5. Early Second Trimester Maternal Plasma Choline and Betaine Are Related to Measures of Early Cognitive Development in Term Infants

    PubMed Central

    Wu, Brian T. F.; Dyer, Roger A.; King, D. Janette; Richardson, Kelly J.; Innis, Sheila M.

    2012-01-01

    Background The importance of maternal dietary choline for fetal neural development and later cognitive function has been well-documented in experimental studies. Although choline is an essential dietary nutrient for humans, evidence that low maternal choline in pregnancy impacts neurodevelopment in human infants is lacking. We determined potential associations between maternal plasma free choline and its metabolites betaine and dimethylglycine in pregnancy and infant neurodevelopment at 18 months of age. Methodology This was a prospective study of healthy pregnant women and their full-term, single birth infants. Maternal blood was collected at 16 and 36 weeks of gestation and infant neurodevelopment was assessed at 18 months of age for 154 mother-infant pairs. Maternal plasma choline, betaine, dimethylglycine, methionine, homocysteine, cysteine, total B12, holotranscobalamin and folate were quantified. Infant neurodevelopment was evaluated using the Bayley Scales of Infant Development–III. Multivariate regression, adjusting for covariates that impact development, was used to determine the associations between maternal plasma choline, betaine and dimethylglycine and infant neurodevelopment. Results The maternal plasma free choline at 16 and 36 weeks gestation was median (interquartile range) 6.70 (5.78–8.03) and 9.40 (8.10–11.3) µmol/L, respectively. Estimated choline intakes were (mean ±SD) 383±98.6 mg/day, and lower than the recommended 450 mg/day. Betaine intakes were 142±70.2 mg/day. Significant positive associations were found between infant cognitive test scores and maternal plasma free choline (B = 6.054, SE = 2.283, p = 0.009) and betaine (B = 7.350, SE = 1.933, p = 0.0002) at 16 weeks of gestation. Maternal folate, total B12, or holotranscobalamin were not related to infant development. Conclusion We show that choline status in the first half of pregnancy is associated with cognitive development among healthy term gestation infants. More work is needed on the potential limitation of choline or betaine in the diets of pregnant women. PMID:22916264

  6. High-performance liquid chromatographic determination of the beta2-selective adrenergic agonist fenoterol in human plasma after fluorescence derivatization.

    PubMed

    Kramer, S; Blaschke, G

    2001-02-10

    A sensitive high-performance liquid chromatographic method has been developed for the determination of the beta2-selective adrenergic agonist fenoterol in human plasma. To improve the sensitivity of the method, fenoterol was derivatized with N-(chloroformyl)-carbazole prior to HPLC analysis yielding highly fluorescent derivatives. The assay involves protein precipitation with acetonitrile, liquid-liquid-extraction of fenoterol from plasma with isobutanol under alkaline conditions followed by derivatization with N-(chloroformyl)-carbazole. Reversed-phase liquid chromatographic determination of the fenoterol derivative was performed using a column-switching system consisting of a LiChrospher 100 RP 18 and a LiChrospher RP-Select B column with acetonitrile, methanol and water as mobile phase. The limit of quantitation in human plasma was 376 pg fenoterol/ml. The method was successfully applied for the assay of fenoterol in patient plasma.

  7. 21 CFR 862.1155 - Human chorionic gonadotropin (HCG) test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intended to measure HCG, a placental hormone, in plasma or urine. (2) Classification. Class II. (b) Human... persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or...

  8. 21 CFR 862.1155 - Human chorionic gonadotropin (HCG) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intended to measure HCG, a placental hormone, in plasma or urine. (2) Classification. Class II. (b) Human... persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or...

  9. 21 CFR 862.1155 - Human chorionic gonadotropin (HCG) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intended to measure HCG, a placental hormone, in plasma or urine. (2) Classification. Class II. (b) Human... persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or...

  10. 21 CFR 862.1155 - Human chorionic gonadotropin (HCG) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intended to measure HCG, a placental hormone, in plasma or urine. (2) Classification. Class II. (b) Human... persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or...

  11. 21 CFR 862.1155 - Human chorionic gonadotropin (HCG) test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intended to measure HCG, a placental hormone, in plasma or urine. (2) Classification. Class II. (b) Human... persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or...

  12. Measurement of the diene conjugated form of linoleic acid in plasma by high performance liquid chromatography: a questionable non-invasive assay of free radical activity?

    PubMed

    Thompson, S; Smith, M T

    1985-11-01

    It has been previously reported that the main diene-conjugated fatty acid in human plasma is a non-oxygen containing linoleic acid isomer (PL-9, 11-LA'). It has also been proposed that this isomer can be used as a specific marker of free radical-mediated lipid peroxidation in humans. Here we report that the in vitro induction of lipid peroxidation in human and rat blood with either UV irradiation or phenylhydrazine failed to increase the plasma levels of this isomer. The induction of lipid peroxidation in vivo in rats pretreated with either phenylhydrazine or bromotrichloromethane also failed to increase the plasma levels of this isomer. These findings demonstrate that PL-9, 11-LA' cannot be used as an in vivo marker of free radical-mediated lipid peroxidation in rats and casts doubts on its validity as a specific marker in humans.

  13. Non-equilibrium plasma prevention of Schistosoma japonicum transmission

    NASA Astrophysics Data System (ADS)

    Wang, Xing-Quan; Wang, Feng-Peng; Chen, Wei; Huang, Jun; Bazaka, Kateryna; Ostrikov, Kostya (Ken)

    2016-10-01

    Schistosoma japonicum is a widespread human and animal parasite that causes intestinal and hepatosplenic schistosomiasis linked to colon, liver and bladder cancers, and anemia. Estimated 230 million people are currently infected with Schistosoma spp, with 779 million people at risk of contracting the parasite. Infection occurs when a host comes into contact with cercariae, a planktonic larval stage of the parasite, and can be prevented by inactivating the larvae, commonly by chemical treatment. We investigated the use of physical non-equilibrium plasma generated at atmospheric pressure using custom-made dielectric barrier discharge reactor to kill S. japonicum cercariae. Survival rate decreased with treatment time and applied power. Plasmas generated in O2 and air gas discharges were more effective in killing S. japonicum cercariae than that generated in He, which is directly related to the mechanism by which cercariae are inactivated. Reactive oxygen species, such as O atoms, abundant in O2 plasma and NO in air plasma play a major role in killing of S. japonicum cercariae via oxidation mechanisms. Similar level of efficacy is also shown for a gliding arc discharge plasma jet generated in ambient air, a system that may be more appropriate for scale-up and integration into existing water treatment processes.

  14. Enhanced Erythropoietin Response to Acute Hypoxemia in Mice with Pharmacological Depression of Erythropoiesis.

    PubMed

    Martínez, M P; Conti, M I; Lezón, C E; Alippi, R M; Bozzini, C E

    1996-01-01

    The recent report of a depression of stimulated production of erythropoietin (EPO) in mice with enhanced erythropoiesis suggests that unknown mechanism (s) other than hypoxia may be involved in the regulation of EPO formation. The present study was thus designed to investigate EPO production during acute hypoxemia in a mouse model in which the oxygen-carrying capacity of blood, the plasma EPO level, and the plasma EPO half-life were within normal values in spite of a marked depression of the red cell production rate (RCPR) induced by cyclophosphamide (CP) administration. Injection of 100 mg/Kg of the drug into adult female CF-1 mice that previously received 0.4 ml of packed red cells depressed markedly the 24-hour RBC 59Fe uptake without affecting the plasma immunoreactive EPO level and the plasma disappearance of 1251-labeled recombinant human EPO. The EPO production rate, calculated from the change in plasma EPO levels and the estimated EPO clearance rate, after 4 h of exposure to hypobaric air was about 2.8 times higher in mice with CP-induced inhibition of the RCPR than in mice with normal RCPR. The results support the hypothesis that the EPO production rate in mammals is not only related to the oxygen supply to the tissues relative to their oxygen needs (main stimulus) but also to the erythroid activity of the marrow (modulatory action).

  15. Identification of peptidase substrates in human plasma by FTMS based differential mass spectrometry

    NASA Astrophysics Data System (ADS)

    Yates, Nathan A.; Deyanova, Ekaterina G.; Geissler, Wayne; Wiener, Matthew C.; Sachs, Jeffrey R.; Wong, Kenny K.; Thornberry, Nancy A.; Sinha Roy, Ranabir; Settlage, Robert E.; Hendrickson, Ronald C.

    2007-01-01

    Approximately 2% of the human genome encodes for proteases. Unfortunately, however, the biological roles of most of these enzymes remain poorly defined, since the physiological substrates are typically unknown and are difficult to identify using traditional methods. We have developed a proteomics experiment based on FTMS profiling and differential mass spectrometry (dMS) to identify candidate endogenous substrates of proteases using fractionated human plasma as the candidate substrate pool. Here we report proof-of-concept experiments for identifying in vitro substrates of aminopeptidase P2, (APP2) and dipeptidyl peptidase 4 (DPP-4), a peptidase of therapeutic interest for the treatment of type 2 diabetes. For both proteases, previously validated peptide substrates spiked into the human plasma pool were identified. Of note, the differential mass spectrometry experiments also identified novel substrates for each peptidase in the subfraction of human plasma. Targeted MS/MS analysis of these peptides in the complex human plasma pool and manual confirmation of the amino acid sequences led to the identification of these substrates. The novel DPP-4 substrate EPLGRQLTSGP was chemically synthesized and cleavage kinetics were determined in an in vitro DPP-4 enzyme assay. The apparent second order rate constant (kcat/KM) for DPP-4-mediated cleavage was determined to be 2.3 x 105 M-1 s-1 confirming that this peptide is efficiently processed by the peptidase in vitro. Collectively, these results demonstrate that differential mass spectrometry has the potential to identify candidate endogenous substrates of target proteases from a human plasma pool. Importantly, knowledge of the endogenous substrates can provide useful insight into the biology of these enzymes and provides useful biomarkers for monitoring their activity in vivo.

  16. Exposures of Sus scrofa to a TASER(®) conducted electrical weapon: no effects on 2-dimensional gel electrophoresis patterns of plasma proteins.

    PubMed

    Jauchem, James R; Cerna, Cesario Z; Lim, Tiffany Y; Seaman, Ronald L

    2014-12-01

    In an earlier study, we found significant changes in red-blood-cell, leukocyte, and platelet counts, and in red-blood-cell membrane proteins, following exposures of anesthetized pigs to a conducted electrical weapon. In the current study, we examined potential changes in plasma proteins [analyzed via two-dimensional gel electrophoresis (2-DGE)] following two 30 s exposures of anesthetized pigs (Sus scrofa) to a TASER (®) C2 conducted electrical weapon. Patterns of proteins, separated by 2-DGE, were consistent and reproducible between animals and between times of sampling. We determined that the blood plasma collection, handling, storage, and processing techniques we used are suitable for swine blood. There were no statistically significant changes in plasma proteins following the conducted-electrical-weapon exposures. Overall gel patterns of fibrinogen were similar to results of other studies of both pigs and humans (in control settings, not exposed to conducted electrical weapons). The lack of significant changes in plasma proteins may be added to the body of evidence regarding relative safety of TASER C2 device exposures.

  17. Blood plasma separation in ZnO nanoflowers-supported paper based microfluidic for glucose sensing

    NASA Astrophysics Data System (ADS)

    Muhimmah, Luthviyah Choirotul; Roekmono, Hadi, Harsono; Yuwono, Rio Akbar; Wahyuono, Ruri Agung

    2018-04-01

    Blood plasma separation is essential to analyze and quantify the bio-substances in the human blood and hence, allows for diagnosing various diseases. This paper presents the two layer paper-based microfluidic analytical devices coated with ZnO nanoflowers (ZnO NF-µPAD) for a rapid blood plasma separation and glucose sensing. Plasma separation in ZnO NF-µPAD was evaluated experimentally and numerically using computational fluid dynamics package for a flow over porous networks. Glucose detection was carried out using Fourier-transform infrared (FTIR) measurements. The glucose concentrations in the red blood samples investigated here vary in the range of 150 - 310 mg.dl-1. The plasma separation process on ZnO NF-μPAD requires 240 ± 93 s. The spectroscopic data reveals that the IR absorptions and Raman signals at the typical vibrational frequencies of glucose are increasing at higher glucose concentration. After subtraction from absorption background arising from ZnO NF and the paper, linearly increasing IR absorption (913 and 1349 cm-1) and Raman signals (1346 and 1461 cm-1) are observable with a relatively good sensitivity.

  18. A new LC-MS/MS bioanalytical method for atenolol in human plasma and milk.

    PubMed

    Phyo Lwin, Ei Mon; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay

    2017-04-01

    A new sensitive LC-MS/MS method for the quantification of atenolol in human plasma and milk has been developed for clinical lactation studies. Atenolol and the internal standard, phenazone, were extracted from biological matrices by protein precipitation. A Phenomenex ® C-18 column and gradient chromatographic conditions were used for separation of the analyte, followed by detection with MS. Stability of samples was confirmed for atenolol in human plasma and milk for up to 3 months. Linearity range of 1-800 ng/ml (r 2 = 0.9995), the precision within 15% CV and the recovery of the analyte (80-100% range) were achieved. A new validated analytical method for atenolol in plasma and milk was developed.

  19. Development and validation of a liquid chromatography-tandem mass spectrometry analytical method for the therapeutic drug monitoring of eight novel anticancer drugs.

    PubMed

    Herbrink, M; de Vries, N; Rosing, H; Huitema, A D R; Nuijen, B; Schellens, J H M; Beijnen, J H

    2018-04-01

    To support therapeutic drug monitoring of patients with cancer, a fast and accurate method for simultaneous quantification of the registered anticancer drugs afatinib, axitinib, ceritinib, crizotinib, dabrafenib, enzalutamide, regorafenib and trametinib in human plasma using liquid chromatography tandem mass spectrometry was developed and validated. Human plasma samples were collected from treated patients and stored at -20°C. Analytes and internal standards (stable isotopically labeled analytes) were extracted with acetonitrile. An equal amount of 10 mm NH 4 CO 3 was added to the supernatant to yield the final extract. A 2 μL aliquot of this extract was injected onto a C 18 -column, gradient elution was applied and triple-quadrupole mass spectrometry in positive-ion mode was used for detection. All results were within the acceptance criteria of the latest US Food and Drug Administration guidance and European Medicines Agency guidelines on method validation, except for the carry-over of ceritinib and crizotinib. These were corrected for by the injection order of samples. Additional stability tests were carried out for axitinib and dabrafenib in relation to their reported photostability. In conclusion, the described method to simultaneously quantify the eight selected anticancer drugs in human plasma was successfully validated and applied for therapeutic drug monitoring in cancer patients treated with these drugs. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Determination of atenolol in human plasma using ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography.

    PubMed

    Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem

    2016-06-01

    An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. An ELISA for SGP28/CRISP-3, a cysteine-rich secretory protein in human neutrophils, plasma, and exocrine secretions.

    PubMed

    Udby, Lene; Cowland, Jack B; Johnsen, Anders H; Sørensen, Ole E; Borregaard, Niels; Kjeldsen, Lars

    2002-05-01

    Specific granule protein of 28 kDa (SGP28), also termed cysteine-rich secretory protein 3 (CRISP-3), is a glycoprotein that belongs to a family of cysteine-rich secretory proteins (CRISPs). SGP28 was originally discovered in human neutrophils, but transcripts are widely distributed in exocrine glands (salivary glands, pancreas, and prostate) and also found at lower levels in epididymis, ovary, thymus, and colon. The function of SGP28/CRISP-3 is not yet known. Similarities to pathogenesis-related proteins in plants and the expression in neutrophils and exocrine glands suggest that SGP28/CRISP-3 may play a role in innate host defense. We describe here the production of a recombinant, C-terminally truncated form of CRISP-3 (rCRISP-3Delta) and the generation of polyclonal antibodies against rCRISP-3Delta that are useful in immunoblotting and immunocytochemistry. We present a specific, accurate, and reproducible enzyme-linked immunosorbant assay (ELISA) for the measurement of CRISP-3 with a detection limit of 2 ng/ml. We further demonstrate the presence of CRISP-3 protein in human plasma (6.3 microg/ml), saliva (21.8 microg/ml), seminal plasma (11.2 microg/ml), and sweat (0.15 microg/ml), and describe the coexistence of two different molecular weight forms of CRISP-3, representing an N-glycosylated and a non-glycosylated form of the mature protein.

  2. High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki

    2016-11-01

    A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na 2 PO 4 H 2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r 2 = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.

  3. Effect of oral administration of GABA on temperature regulation in humans during rest and exercise at high ambient temperature.

    PubMed

    Miyazawa, Taiki; Kawabata, Takashi; Suzuki, Takashi; Imai, Daiki; Hamamoto, Takeshi; Yoshikawa, Takahiro; Miyagawa, Toshiaki

    2009-12-01

    Centric administration of gamma-aminobutyric acid (GABA) has been implicated to affect temperature regulation in animals during rest or under anesthesia. However, there are few reports concerning the effects of the oral administration of GABA on temperature regulation in humans during rest and exercise. In order to clarify the effects and underlying mechanisms, we measured several parameters related to temperature regulation of humans during rest and exercise at high ambient temperature (35 degrees C). On two occasions, eight endurance-trained men rested for 20 min and cycled at 65% VO2peak for 30 min. In control trial (trial-C), subjects drank the sample which was a sports drink of 200 mL (placebo) before the rest period. In another trial (trial-G), subjects drank the sample which was a sports drink containing 1000 mg of GABA (GABA drink) before the rest period. In trial-G, the plasma GABA concentrations were maintained higher than those in trial-C during the experiment. An increase of esophageal temperature during rest and exercise was inhibited in trial-G. Sweat rate, and plasma catecholamine concentrations during exercise were inhibited in trial-G. Esophageal temperature inhibition is suggested to be induced by the suppression of cold-sensitive neurons during rest, and the inhibition of plasma catecholamine concentrations caused by the GABA-induced attenuation of the sympathetic nervous system during exercise.

  4. UPLC-MS-MS Method for the Determination of Vilazodone in Human Plasma: Application to a Pharmacokinetic Study.

    PubMed

    El-Bagary, Ramzia; Hashem, Hanaa; Fouad, Marwa; Tarek, Sally

    2016-09-01

    A sensitive, rapid and simple liquid chromatographic-electrospray ionization tandem mass spectrometric (LC-ESI-MS-MS) method was developed for the quantitative determination of vilazodone in human plasma and for the study of the pharmacokinetic behavior of vilazodone in healthy Egyptian volunteers. With escitalopram as internal standard (IS), liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix using diethyl ether. The separation was performed on an Acquity UPLC BEH shield RP C18 column (1.7 µm, 2.1 × 150 mm). Isocratic elution was applied using methanol-0.2% formic acid (90:10, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring mode via an electrospray ionization source at m/z 442.21 → 155.23 for vilazodone and m/z 325.14 → 109.2 for escitalopram. Linear calibration curves were obtained over the range of 1-200 ng/mL with the lower limit of quantification at 1 ng/mL. The intra- and inter-day precision showed relative standard deviation ≤3.3%. The total run time was 1.5 min. This method was successfully applied for clinical pharmacokinetic investigation, and a preliminary metabolic study was also carried out. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Metabolic Disposition of Osimertinib in Rats, Dogs, and Humans: Insights into a Drug Designed to Bind Covalently to a Cysteine Residue of Epidermal Growth Factor Receptor.

    PubMed

    Dickinson, Paul A; Cantarini, Mireille V; Collier, Jo; Frewer, Paul; Martin, Scott; Pickup, Kathryn; Ballard, Peter

    2016-08-01

    Preclinical and clinical studies were conducted to determine the metabolism and pharmacokinetics of osimertinib and key metabolites AZ5104 and AZ7550. Osimertinib was designed to covalently bind to epidermal growth factor receptors, allowing it to achieve nanomolar cellular potency (Finlay et al., 2014). Covalent binding was observed in incubations of radiolabeled osimertinib with human and rat hepatocytes, human and rat plasma, and human serum albumin. Osimertinib, AZ5104, and AZ7550 were predominantly metabolized by CYP3A. Seven metabolites were detected in human hepatocytes, also observed in rat or dog hepatocytes at similar or higher levels. After oral administration of radiolabeled osimertinib to rats, drug-related material was widely distributed, with the highest radioactivity concentrations measured at 6 hours postdose in most tissues; radioactivity was detectable in 42% of tissues 60 days postdose. Concentrations of [(14)C]-radioactivity in blood were lower than in most tissues. After the administration of a single oral dose of 20 mg of radiolabeled osimertinib to healthy male volunteers, ∼19% of the dose was recovered by 3 days postdose. At 84 days postdose, mean total radioactivity recovery was 14.2% and 67.8% of the dose in urine and feces. The most abundant metabolite identified in feces was AZ5104 (∼6% of dose). Osimertinib accounted for ∼1% of total radioactivity in the plasma of non-small cell lung cancer patients after 22 days of 80-mg osimertinib once-daily treatment; the most abundant circulatory metabolites were AZ7550 and AZ5104 (<10% of total osimertinib-related material). Osimertinib is extensively distributed and metabolized in humans and is eliminated primarily via the fecal route. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  6. Glycation sites of human plasma proteins are affected to different extents by hyperglycemic conditions in type 2 diabetes mellitus.

    PubMed

    Frolov, Andrej; Blüher, Matthias; Hoffmann, Ralf

    2014-09-01

    Glucose can modify proteins in human blood, forming early glycation products (e.g., Amadori compounds), which can slowly degrade to advanced glycation endproducts (AGEs). AGEs contribute significantly to complications of diabetes mellitus and, thus, represent markers of advanced disease stages. They are, however, currently unsuitable for early diagnosis and therapeutic monitoring. Here, we report sensitive strategies to identify and relatively quantify protein glycation sites in human plasma samples obtained from type 2 diabetes mellitus (T2DM) patients and age-matched nondiabetic individuals using a bottom-up approach. Specifically, Amadori peptides were enriched from tryptic digests by boronic acid affinity chromatography, separated by reversed-phase chromatography, and analyzed on-line by high-resolution mass spectrometry. Among the 52 Amadori peptides studied here were 20 peptides resembling 19 glycation sites in six human proteins detected at statistically significantly higher levels in T2DM than in the normoglycemic controls. Four positions appeared to be unique for T2DM within the detection limit. All 19 glycation sites represent promising new biomarker candidates for early diagnosis of T2DM and adequate therapeutic control, as they may indicate early metabolic changes preceding T2DM.

  7. Biomonitoring of perfluorinated compounds in a drop of blood.

    PubMed

    Mao, Pan; Wang, Daojing

    2015-06-02

    Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.

  8. Human leukocyte antigen-G in the male reproductive system and in seminal plasma.

    PubMed

    Larsen, Margit Hørup; Bzorek, Michael; Pass, Malene B; Larsen, Lise Grupe; Nielsen, Mette Weidinger; Svendsen, Signe Goul; Lindhard, Anette; Hviid, Thomas Vauvert F

    2011-12-01

    One of the non-classical human leukocyte antigen (HLA) class Ib proteins, HLA-G, is believed to exert important immunoregulatory functions, especially during pregnancy. The presence of HLA protein in paternal seminal fluid has been suggested to have an influence on the risk of developing pre-eclampsia. We have investigated whether HLA-G protein is present in human seminal plasma and in different tissue samples of the male reproductive system. Western blot technique and a soluble HLA-G (sHLA-G) assay were used to detect sHLA-G in human seminal plasma samples. Immunohistochemical staining was performed on paraffin-embedded tissue samples. We detected sHLA-G protein in seminal plasma, and HLA-G expression in normal testis and in epididymal tissue of the male reproductive system but not in the seminal vesicle. Furthermore, the results indicated a weak expression of HLA-G in hyperplastic prostatic tissue. In summary, several of the findings reported in this study suggest an immunoregulatory role of HLA-G in the male reproductive system and in seminal plasma.

  9. The Influence of Probiotic Lactobacillus casei in Combination with Prebiotic Inulin on the Antioxidant Capacity of Human Plasma

    PubMed Central

    Kleniewska, Paulina; Hoffmann, Arkadiusz; Pniewska, Ewa

    2016-01-01

    The aim of the present study was to assess whether probiotic bacteria Lactobacillus casei (4 × 108 CFU) influences the antioxidant properties of human plasma when combined with prebiotic Inulin (400 mg). Experiments were carried out on healthy volunteers (n = 32). Volunteers were divided according to sex (16 male and 16 female) and randomly assigned to synbiotic and control groups. Blood samples were collected before synbiotic supplementation and after 7 weeks, at the end of the study. Catalase (CAT), superoxide dismutase (SOD), glutathione peroxidase (GPx) activity, and the ferric reducing ability of plasma (FRAP) in human plasma were examined. The administration of synbiotics containing L. casei plus Inulin resulted in a significant increase in FRAP values (p = 0.00008) and CAT activity (p = 0.02) and an insignificant increase in SOD and GPx activity compared to controls. Synbiotics containing L. casei (4 × 108 CFU) with prebiotic Inulin (400 mg) may have a positive influence on human plasma antioxidant capacity and the activity of selected antioxidant enzymes. PMID:27066188

  10. Diisopropylfluorophosphate-sensitive aryl acylamidase activity of fatty acid free human serum albumin.

    PubMed

    Manoharan, Indumathi; Boopathy, Rathnam

    2006-08-15

    Butyrylcholinesterase in human plasma and acetylcholinesterase in human red blood cells have aryl acylamidase activity toward o-nitroacetanilide, hydrolyzing the amide bond to produce o-nitroaniline and acetate. People with a genetic variant of butyrylcholinesterase that had no detectable activity with butyrylthiocholine, nevertheless had aryl acylamidase activity in their plasma. To determine the source of this aryl acylamidase activity we tested fatty acid free human albumin for activity. We found that albumin had aryl acylacylamidase activity and that this activity was inhibited by diisopropylfluorophosphate. Since the esterase activity of albumin is also inhibited by diisopropylfluorophosphate, and since it is known that diisopropylfluorophosphate covalently binds to Tyr 411 of human albumin, we conclude that the active site for aryl acylamidase activity of albumin is Tyr 411. Albumin accounts for about 10% of the aryl acylamidase activity in human plasma.

  11. Choline and betaine in health and disease.

    PubMed

    Ueland, Per Magne

    2011-02-01

    Choline is an essential nutrient, but is also formed by de novo synthesis. Choline and its derivatives serve as components of structural lipoproteins, blood and membrane lipids, and as a precursor of the neurotransmitter acetylcholine. Pre-and postnatal choline availability is important for neurodevelopment in rodents. Choline is oxidized to betaine that serves as an osmoregulator and is a substrate in the betaine-homocysteine methyltransferase reaction, which links choline and betaine to the folate-dependent one-carbon metabolism. Choline and betaine are important sources of one-carbon units, in particular, during folate deficiency. Choline or betaine supplementation in humans reduces concentration of total homocysteine (tHcy), and plasma betaine is a strong predictor of plasma tHcy in individuals with low plasma concentration of folate and other B vitamins (B₂, B₆, and B₁₂) in combination TT genotype of the methylenetetrahydrofolate reductase 677 C->T polymorphism. The link to one-carbon metabolism and the recent availability of food composition data have motivated studies on choline and betaine as risk factors of chronic diseases previously studied in relation to folate and homocysteine status. High intake and plasma level of choline in the mother seems to afford reduced risk of neural tube defects. Intake of choline and betaine shows no consistent relation to cancer or cardiovascular risk or risk factors, whereas an unfavorable cardiovascular risk factor profile was associated with high choline and low betaine concentrations in plasma. Thus, choline and betaine showed opposite relations with key components of metabolic syndrome, suggesting a disruption of mitochondrial choline oxidation to betaine as part of the mitochondrial dysfunction in metabolic syndrome.

  12. VEGF-121 plasma level as biomarker for response to anti-angiogenetic therapy in recurrent glioblastoma.

    PubMed

    Martini, Maurizio; de Pascalis, Ivana; D'Alessandris, Quintino Giorgio; Fiorentino, Vincenzo; Pierconti, Francesco; Marei, Hany El-Sayed; Ricci-Vitiani, Lucia; Pallini, Roberto; Larocca, Luigi Maria

    2018-05-10

    Vascular endothelial growth factor (VEGF) isoforms, particularly the diffusible VEGF-121, could play a major role in the response of recurrent glioblastoma (GB) to anti-angiogenetic treatment with bevacizumab. We hypothesized that circulating VEGF-121 may reduce the amount of bevacizumab available to target the heavier isoforms of VEGF, which are the most clinically relevant. We assessed the plasma level of VEGF-121 in a brain xenograft model, in human healthy controls, and in patients suffering from recurrent GB before and after bevacizumab treatment. Data were matched with patients' clinical outcome. In athymic rats with U87MG brain xenografts, the level of plasma VEGF-121 relates with tumor volume and it significantly decreases after iv infusion of bevacizumab. Patients with recurrent GB show higher plasma VEGF-121 than healthy controls (p = 0.0002) and treatment with bevacizumab remarkably reduced the expression of VEGF-121 in plasma of these patients (p = 0.0002). Higher plasma level of VEGF-121 was significantly associated to worse PFS and OS (p = 0.0295 and p = 0.0246, respectively). Quantitative analysis of VEGF-121 isoform in the plasma of patients with recurrent GB could be a promising predictor of response to anti-angiogenetic treatment.

  13. Effect of dietary fat source on lipoprotein composition and plasma lipid concentrations in pigs.

    PubMed

    Faidley, T D; Luhman, C M; Galloway, S T; Foley, M K; Beitz, D C

    1990-10-01

    Most studies of the effects of dietary fat sources on plasma lipid components have used diets with extreme fat compositions; the current study was designed to more nearly mimic human dietary fat intake. Young growing pigs were fed diets containing either 20 or 40% of energy as soy oil, beef tallow or a 50/50 blend of soy oil and tallow. Different dietary fats did not affect concentrations of cholesterol, triacylglycerol or protein in plasma or major lipoprotein fractions. The concentration of phospholipid was less in plasma and in very low density lipoproteins with soy oil feeding than with tallow feeding. The weight percentage of cholesteryl ester in the low density lipoprotein fraction tended to be greater with 40% than with 20% tallow and tended to be less with 40% than with 20% soy oil. Phospholipid as a weight percentage of low density lipoprotein was least in pigs fed soy oil. Tallow feeding increased the percentage of myristic, palmitic, palmitoleic and oleic acids in plasma, relative to both other groups. Soy oil feeding increased the percentage of linoleic and linolenic acids. These moderate diets were not hypercholesterolemic, but they did alter plasma fatty acid composition and phospholipid concentrations in plasma and very low density lipoprotein.

  14. 21 CFR 866.2160 - Coagulase plasma.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulase plasma. 866.2160 Section 866.2160 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2160 Coagulase plasma. (a) Identification. Coagulase plasma is a device that consists of freeze-dried animal or human plasma that is...

  15. 21 CFR 866.2160 - Coagulase plasma.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Coagulase plasma. 866.2160 Section 866.2160 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2160 Coagulase plasma. (a) Identification. Coagulase plasma is a device that consists of freeze-dried animal or human plasma that is...

  16. 21 CFR 866.2160 - Coagulase plasma.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Coagulase plasma. 866.2160 Section 866.2160 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2160 Coagulase plasma. (a) Identification. Coagulase plasma is a device that consists of freeze-dried animal or human plasma that is...

  17. 21 CFR 866.2160 - Coagulase plasma.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Coagulase plasma. 866.2160 Section 866.2160 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2160 Coagulase plasma. (a) Identification. Coagulase plasma is a device that consists of freeze-dried animal or human plasma that is...

  18. 21 CFR 866.2160 - Coagulase plasma.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Coagulase plasma. 866.2160 Section 866.2160 Food... DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2160 Coagulase plasma. (a) Identification. Coagulase plasma is a device that consists of freeze-dried animal or human plasma that is...

  19. A semi-automated multiplex high-throughput assay for measuring IgG antibodies against Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) domains in small volumes of plasma.

    PubMed

    Cham, Gerald K K; Kurtis, Jonathan; Lusingu, John; Theander, Thor G; Jensen, Anja T R; Turner, Louise

    2008-06-12

    The level of antibodies against PfEMP1 is routinely quantified by the conventional microtitre enzyme-linked immunosorbent assay (ELISA). However, ELISA only measures one analyte at a time and requires a relatively large plasma volume if the complete antibody profile of the sample is to be obtained. Furthermore, assay-to-assay variation and the problem of storage of antigen can influence ELISA results. The bead-based assay described here uses the BioPlex100 (BioRad, Hercules, CA, USA) system which can quantify multiple antibodies simultaneously in a small plasma volume. A total of twenty nine PfEMP1 domains were PCR amplified from 3D7 genomic DNA, expressed in the Baculovirus system and purified by metal-affinity chromatography. The antibody reactivity level to the recombinant PfEMP1 proteins in human hyper-immune plasma was measured by ELISA. In parallel, these recombinant PfEMP1 proteins were covalently coupled onto beads each having its own unique detection signal and the human hyper-immune plasma reactivity was detected for each individual protein using a BioPlex100 system. Protein-coupled beads were analysed at two time points seven months apart, before and after lyophilization and the results compared to determine the effect of storage and lyophilization respectively on the beads. Multiplexed protein-coupled beads from twenty eight unique bead populations were evaluated on the BioPlex100 system against pooled human hyper-immune plasma before and after lyophilization. The bead-based assay was sensitive, accurate and reproducible. Four recombinant PfEMP1 proteins C17, D5, D9 and D12, selected on the basis that they showed a spread of median fluorescent intensity (MFI) values from low to high when analysed by the bead-based assay were analysed by ELISA and the results from both analyses were highly correlated. The Spearman's rank correlation coefficients (Rho) were > or = 0.86, (P < 0.0001) for all comparisons. Bead-based assays gave similar results regardless of whether they were performed on individual beads or on multiplexed beads; lyophilization had no impact on the assay performance. Spearman's rank correlation coefficients (Rho) were > or = 0.97, (P < 0.0001) for all comparisons. Importantly, the reactivity of protein-coupled non-lyophilized beads decreased with long term storage at 4 degrees C in the dark. Using this lyophilized multiplex assay, antibody reactivity levels to twenty eight different recombinant PfEMP1 proteins were simultaneously measured using a single microliter of plasma. Thus, the assay reported here provides a useful tool for rapid and efficient quantification of antibody reactivity against PfEMP1 variants in human plasma.

  20. Association of Roadway Proximity with Fasting Plasma Glucose and Metabolic Risk Factors for Cardiovascular Disease in a Cross-Sectional Study of Cardiac Catheterization Patients

    EPA Science Inventory

    Background: The relationship between traffic-related air pollution (TRAP) and risk factors for cardiovascular disease needs to be better understood in order to address the adverse impact o.f air pollution on human health.Objective: We examined associations between roadway proximi...

  1. Two independent apolipoprotein A5 haplotypes influence human plasma triglyceride levels.

    PubMed

    Pennacchio, Len A; Olivier, Michael; Hubacek, Jaroslav A; Krauss, Ronald M; Rubin, Edward M; Cohen, Jonathan C

    2002-11-15

    The recently identified apolipoprotein A5 gene (APOA5) has been shown to play an important role in determining plasma triglyceride concentrations in humans and mice. We previously identified an APOA5 haplotype (designated APOA5*2) that is present in approximately 16% of Caucasians and is associated with increased plasma triglyceride concentrations. In this report we describe another APOA5 haplotype (APOA5*3) containing the rare allele of the single nucleotide polymorphism c.56C>G that changes serine to tryptophan at codon 19 and is independently associated with high plasma triglyceride levels in three different populations. In a sample of 264 Caucasian men and women with plasma triglyceride concentrations above the 90th percentile or below the 10th percentile, the APOA5*3 haplotype was more than three-fold more common in the group with high plasma triglyceride levels. In a second independently ascertained sample of Caucasian men and women (n=419) who were studied while consuming their self-selected diets as well as after high-carbohydrate diets and high-fat diets, the APOA5*3 haplotype was associated with increased plasma triglyceride levels on all three dietary regimens. In a third population comprising 2660 randomly selected individuals, the APOA5*3 haplotype was found in 12% of Caucasians, 14% of African-Americans and 28% of Hispanics and was associated with increased plasma triglyceride levels in both men and women in each ethnic group. These findings establish that the APOA5 locus contributes significantly to inter-individual variation in plasma triglyceride levels in humans. Together, the APOA5*2 and APOA5*3 haplotypes are found in 25-50% of African-Americans, Hispanics and Caucasians and support the contribution of common human variation to quantitative phenotypes in the general population.

  2. Plasma lead, silicon and titanium concentrations are considerably higher in green sea turtle from the suburban coast than in those from the rural coast in Okinawa, Japan

    PubMed Central

    TSUKANO, Kenji; SUZUKI, Kazuyuki; NODA, Jun; YANAGISAWA, Makio; KAMEDA, Kazunari; SERA, Koichiro; NISHI, Yasunobu; SHIMAMORI, Toshio; MORIMOTO, Yasuyo; YOKOTA, Hiroshi; ASAKAWA, Mitsuhiko

    2017-01-01

    The purpose of this study was to compare the concentration of trace elements in the plasma of sea turtles that inhabited the suburban (Okinawa Main Island, n=8) and the rural coast (Yaeyama Island, n=57) in Okinawa, Japan. Particle induced X-ray emission allowed detection of 20 trace and major elements. The wild sea turtles in the suburban coast in Okinawa were found to have high concentrations of Pb, Si and Ti in the plasma when compared to the rural area but there were no significant changes in the Al, As and Hg concentrations. These results may help to suggest the status of some elements in a marine environment. Further, monitoring the plasma trace and major element status in sea turtles can be used as a bio-monitoring approach by which specific types of elements found here could indicate effects that are related to human activities. PMID:29070764

  3. Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Van Beaumont, W.; Brock, P. J.; Montgomery, L. D.; Morse, J. T.; Shvartz, E.; Kravik, S.

    1980-01-01

    The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

  4. Bactericidal active ingredient in cryopreserved plasma-treated water with the reduced-pH method for plasma disinfection

    NASA Astrophysics Data System (ADS)

    Kitano, Katsuhisa; Ikawa, Satoshi; Nakashima, Yoichi; Tani, Atsushi; Yokoyama, Takashi; Ohshima, Tomoko

    2016-09-01

    For the plasma disinfection of human body, plasma sterilization in liquid is crucial. We found that the plasma-treated water (PTW) has strong bactericidal activity under low pH condition. Physicochemical properties of PTW is discussed based on chemical kinetics. Lower temperature brings longer half-life and the bactericidal activity of PTW can be kept by cryopreservation. High performance PTW, corresponding to the disinfection power of 22 log reduction (B. subtilis spore), can be obtained by special plasma system equipped with cooling device. This is equivalent to 65% H2O2, 14% sodium hypochlorite and 0.33% peracetic acid, which are deadly poison for human. But, it is deactivated soon at higher temperature (4 sec. at body temperature), and toxicity to human body seems low. For dental application, PTW was effective on infected models of human extracted tooth. Although PTW has many chemical components, respective chemical components in PTW were isolated by ion chromatography. In addition to peaks of H2O2, NO2- and NO3-, a specific peak was detected. and only this fraction had bactericidal activity. Purified active ingredient of PTW is the precursor of HOO, and further details will be discussed in the presentation. MEXT (15H03583, 23340176, 25108505). NCCE (23-A-15).

  5. Recombinant human growth hormone in treatment of diabetes: report of three cases and review of relative literature

    PubMed Central

    Wang, Dandan; Zhao, Naicheng; Zhu, Ziyang

    2015-01-01

    To explore the clinical profile and laboratory changes in three patients with diabetes mellitus treated with recombinant human growth hormone (rhGH). Results showed that the patient in the first case was diagnosed as T1DM according to the classical course of disease, weight loss, polyuria, polydispsia, polyphagia, and positive GAD-Ab. The second patient’s plasma glucose and urine glucose were at a high level, then stored immediately with the negative OGTT. But, the level of insulin increased significantly suggesting there is insulin resistance. In the last case, fasting plasma glucose level was higher than 7.0 mmol/l several times. The level of HbA1c increased. In an oral glucose tolerance test (OGTT), fasting glucose > 7.0 mmol/l, plasma glucose < 7.8 mmol/l two hours after a 75 g oral glucose load. We postulate that the higher than expected incidence of type 2 diabetes mellitus with GH treatment may be an acceleration of the disorder in predisposed individuals. The rhGH therapy may eventually induce transitory glucose metabolic disorder in a very small proportion of patients, which was restored gradually after the discontinuance of rhGH. PMID:26221404

  6. Lipolysis, and not hepatic lipogenesis, is the primary modulator of triglyceride levels in streptozotocin-induced diabetic mice

    PubMed Central

    Willecke, Florian; Scerbo, Diego; Nagareddy, Prabhakara; Obunike, Joseph C; Barrett, Tessa J; Abdillahi, Mariane L.; Trent, Chad M.; Huggins, Lesley Ann; Fisher, Edward A; Drosatos, Konstantinos; Goldberg, Ira J.

    2014-01-01

    Objective Diabetic hypertriglyceridemia is thought to be primarily driven by increased hepatic de novo lipogenesis. However, experiments in animal models indicated that insulin deficiency should decrease hepatic de novo lipogenesis and reduce plasma triglyceride levels. Approach and Results To address the discrepancy between human data and genetically altered mouse models, we investigated whether insulin deficient diabetic mice had triglyceride changes that resemble those in diabetic humans. Streptozotocin (STZ)–induced insulin deficiency increased plasma triglyceride levels in mice. Contrary to the mouse models with impaired hepatic insulin receptor signalling, insulin deficiency did not reduce hepatic triglyceride secretion and de novo lipogenesis-related gene expression. Diabetic mice had a marked decrease in postprandial TG clearance, which was associated with decreased lipoprotein lipase (LpL) and PPARα mRNA levels in peripheral tissues and decreased LpL activity in skeletal muscle, heart and brown adipose tissue. Diabetic heterozygous LpL knockout mice had markedly elevated fasting plasma triglyceride levels and prolonged postprandial TG clearance. Conclusion Insulin deficiency causes hypertriglyceridemia by decreasing peripheral lipolysis and not by an increase in hepatic TG production and secretion. PMID:25395613

  7. Plasma Shh levels reduced in pancreatic cancer patients

    PubMed Central

    El-Zaatari, Mohamad; Daignault, Stephanie; Tessier, Art; Kelsey, Gail; Travnikar, Lisa A.; Cantu, Esperanza F.; Lee, Jamie; Plonka, Caitlyn M.; Simeone, Diane M.; Anderson, Michelle A.; Merchant, Juanita L.

    2012-01-01

    Objectives Normally, sonic hedgehog (Shh) is expressed in the pancreas during fetal development and transiently after tissue injury. Although pancreatic cancers express Shh, it is not known if the protein is secreted into the blood and whether its plasma levels change with pancreatic transformation. The goal of this study was to develop an ELISA to detect human Shh in blood, and determine the levels in subjects with and without pancreatic cancer. Methods A human Shh ELISA assay was developed, and plasma Shh levels were measured in blood samples from normal volunteers and subjects with pancreatitis or pancreatic cancer. The biological activity of plasma Shh was tested using NIH-3T3 cells. Results The average levels of Shh in human blood were lower in pancreatitis and pancreatic cancer patients than in normal individuals. Hematopoietic cells did not express Shh suggesting that Shh is secreted into the bloodstream. Plasma fractions enriched for Shh did not induce Gli-1 mRNA suggesting that the protein was not biologically active. Conclusions Shh is secreted from tissues and organs into the circulation but its activity is blocked by plasma proteins. Reduced plasma levels were found in pancreatic cancer patients, but alone were not sufficient to predict pancreatic cancer. PMID:22513293

  8. Plasma Shh levels reduced in pancreatic cancer patients.

    PubMed

    El-Zaatari, Mohamad; Daignault, Stephanie; Tessier, Art; Kelsey, Gail; Travnikar, Lisa A; Cantu, Esperanza F; Lee, Jamie; Plonka, Caitlyn M; Simeone, Diane M; Anderson, Michelle A; Merchant, Juanita L

    2012-10-01

    Normally, sonic hedgehog (Shh) is expressed in the pancreas during fetal development and transiently after tissue injury. Although pancreatic cancers express Shh, it is not known if the protein is secreted into the blood and whether its plasma levels change with pancreatic transformation. The goal of this study was to develop an enzyme-linked immunosorbent assay to detect human Shh in blood and determine its levels in subjects with and without pancreatic cancer. A human Shh enzyme-linked immunosorbent assay was developed, and plasma Shh levels were measured in blood samples from healthy subjects and patients with pancreatitis or pancreatic cancer. The biological activity of plasma Shh was tested using NIH-3T3 cells. The mean levels of Shh in human blood were lower in patients with pancreatitis and pancreatic cancer than in healthy subjects. Hematopoietic cells did not express Shh, suggesting that Shh is secreted into the bloodstream. Plasma fractions enriched with Shh did not induce Gli-1 messenger RNA, suggesting that the protein was not biologically active. Shh is secreted from tissues and organs into the circulation, but its activity is blocked by plasma proteins. Reduced plasma levels were found in pancreatic cancer patients, but alone were not sufficient to predict pancreatic cancer.

  9. EFFECT OF ε-AMINOCAPROIC ACID ON FIBRINOLYSIS IN PLASMA OF ASIAN ELEPHANTS (ELEPHAS MAXIMUS).

    PubMed

    Kaye, Sarrah; Abou-Madi, Noha; Fletcher, Daniel J

    2016-06-01

    ε-Aminocaproic acid (EACA) is a lysine analogue antifibrinolytic drug used to treat bleeding disorders in humans and domestic animals. Use in zoological medicine is rare and dose recommendations are anecdotal, but EACA may be a valuable therapeutic option for bleeding disorders in exotic species, including Asian elephants ( Elephas maximus ). This study used an in vitro model of hyperfibrinolysis and a thromboelastograph-based assay to estimate the therapeutic plasma concentration of EACA in Asian elephants (61.5 μg/ml, 95% CI = 34.6-88.5 μg/ml). Substantial but incomplete inhibition of lysis was seen at relatively low concentrations of EACA (40 μg/ml). Asian elephants appear sensitive to EACA-mediated inhibition of hyperfibrinolysis. Doses published for domestic animals, targeting higher plasma concentrations, may be inappropriate in this species.

  10. The Plasma Membrane Calcium ATPases and Their Role as Major New Players in Human Disease.

    PubMed

    Stafford, Nicholas; Wilson, Claire; Oceandy, Delvac; Neyses, Ludwig; Cartwright, Elizabeth J

    2017-07-01

    The Ca 2+ extrusion function of the four mammalian isoforms of the plasma membrane calcium ATPases (PMCAs) is well established. There is also ever-increasing detail known of their roles in global and local Ca 2+ homeostasis and intracellular Ca 2+ signaling in a wide variety of cell types and tissues. It is becoming clear that the spatiotemporal patterns of expression of the PMCAs and the fact that their abundances and relative expression levels vary from cell type to cell type both reflect and impact on their specific functions in these cells. Over recent years it has become increasingly apparent that these genes have potentially significant roles in human health and disease, with PMCAs1-4 being associated with cardiovascular diseases, deafness, autism, ataxia, adenoma, and malarial resistance. This review will bring together evidence of the variety of tissue-specific functions of PMCAs and will highlight the roles these genes play in regulating normal physiological functions and the considerable impact the genes have on human disease. Copyright © 2017 the American Physiological Society.

  11. MRM validation of targeted nonglycosylated peptides from N-glycoprotein biomarkers using direct trypsin digestion of undepleted human plasma.

    PubMed

    Lee, Ju Yeon; Kim, Jin Young; Cheon, Mi Hee; Park, Gun Wook; Ahn, Yeong Hee; Moon, Myeong Hee; Yoo, Jong Shin

    2014-02-26

    A rapid, simple, and reproducible MRM-based validation method for serological glycoprotein biomarkers in clinical use was developed by targeting the nonglycosylated tryptic peptides adjacent to N-glycosylation sites. Since changes in protein glycosylation are known to be associated with a variety of diseases, glycoproteins have been major targets in biomarker discovery. We previously found that nonglycosylated tryptic peptides adjacent to N-glycosylation sites differed in concentration between normal and hepatocellular carcinoma (HCC) plasma due to differences in steric hindrance of the glycan moiety in N-glycoproteins to tryptic digestion (Lee et al., 2011). To increase the feasibility and applicability of clinical validation of biomarker candidates (nonglycosylated tryptic peptides), we developed a method to effectively monitor nonglycosylated tryptic peptides from a large number of plasma samples and to reduce the total analysis time with maximizing the effect of steric hindrance by the glycans during digestion of glycoproteins. The AUC values of targeted nonglycosylated tryptic peptides were excellent (0.955 for GQYCYELDEK, 0.880 for FEDGVLDPDYPR and 0.907 for TEDTIFLR), indicating that these could be effective biomarkers for hepatocellular carcinoma. This method provides the necessary throughput required to validate glycoprotein biomarkers, as well as quantitative accuracy for human plasma analysis, and should be amenable to clinical use. Difficulties in verifying and validating putative protein biomarkers are often caused by complex sample preparation procedures required to determine their concentrations in a large number of plasma samples. To solve the difficulties, we developed MRM-based protein biomarker assays that greatly reduce complex, time-consuming, and less reproducible sample pretreatment steps in plasma for clinical implementation. First, we used undepleted human plasma samples without any enrichment procedures. Using nanoLC/MS/MS, we targeted nonglycosylated tryptic peptides adjacent to N-linked glycosylation sites in N-linked glycoprotein biomarkers, which could be detected in human plasma samples without depleting highly abundant proteins. Second, human plasma proteins were digested with trypsin without reduction and alkylation procedures to minimize sample preparation. Third, trypsin digestion times were shortened so as to obtain reproducible results with maximization of the steric hindrance effect of the glycans during enzyme digestion. Finally, this rapid and simple sample preparation method was applied to validate targeted nonglycosylated tryptic peptides as liver cancer biomarker candidates for diagnosis in 40 normal and 41 hepatocellular carcinoma (HCC) human plasma samples. This strategy provided the necessary throughput required to monitor protein biomarkers, as well as quantitative accuracy in human plasma analysis. From biomarker discovery to clinical implementation, our method will provide a biomarker study platform that is suitable for clinical deployment, and can be applied to high-throughput approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Multi-component immunoaffinity subtraction chromatography: an innovative step towards a comprehensive survey of the human plasma proteome.

    PubMed

    Pieper, Rembert; Su, Qin; Gatlin, Christine L; Huang, Shih-Ting; Anderson, N Leigh; Steiner, Sandra

    2003-04-01

    In order to discover novel protein markers indicative of disease processes or drug effects, the proteomics technology platform most commonly used consists of high resolution protein separation by two-dimensional electrophoresis (2-DE), mass spectrometric identification of proteins from stained gel spots and a bioinformatic data analysis process supported by statistics. This approach has been more successful in profiling proteins and their disease- or treatment-related quantitative changes in tissue homogenates than in plasma samples. Plasma protein display and quantitation suffer from several disadvantages: very high abundance of a few proteins; high heterogeneity of many proteins resulting in long charge trains; crowding of 2-DE separated protein spots in the molecular mass range between 45-80 kD and in the isoelectric point range between 4.5 and 6. Therefore, proteomic technologies are needed that address these problems and particularly allow accurate quantitation of a larger number of less abundant proteins in plasma and other body fluids. The immunoaffinity-based protein subtraction chromatography (IASC) described here removes multiple proteins present in plasma and serum in high concentrations effectively and reproducibly. Applying IASC as an upfront plasma sample preparation process for 2-DE, the protein spot pattern observed in gels changes dramatically and at least 350 additional lower abundance proteins are visualized. Affinity-purified polyclonal antibodies (pAbs) are the immunoaffinity reagents used to specifically remove the abundant proteins such as albumin, immunoglobulin G, immunoglobulin A, transferrin, haptoglobin, alpha-1-antitrypsin, hemopexin, transthyretin, alpha-2-HS glycoprotein, alpha-1-acid glycoprotein, alpha-2-macroglobulin and fibrinogen from human plasma samples. To render the immunoaffinity subtraction procedure recyclable, the pAbs are immobilized and cross-linked on chromatographic matrices. Antibody-coupled matrices specific for one protein each can be pooled to form mixed-bed IASC columns. We show that up to ten affinity-bound plasma proteins with similar solubility characteristics are eluted from a mixed-bed column in one step. This facilitates automated chromatographic processing of plasma samples in high throughput, which is desirable in proteomic disease marker discovery projects.

  13. Effects of Acute Exposure to Increased Plasma Branched-Chain Amino Acid Concentrations on Insulin-Mediated Plasma Glucose Turnover in Healthy Young Subjects

    PubMed Central

    Everman, Sarah; Mandarino, Lawrence J.; Carroll, Chad C.; Katsanos, Christos S.

    2015-01-01

    Background Plasma branched-chain amino acids (BCAA) are inversely related to insulin sensitivity of glucose metabolism in humans. However, currently, it is not known whether there is a cause-and-effect relationship between increased plasma BCAA concentrations and decreased insulin sensitivity. Objective To determine the effects of acute exposure to increased plasma BCAA concentrations on insulin-mediated plasma glucose turnover in humans. Methods Ten healthy subjects were randomly assigned to an experiment where insulin was infused at 40 mU/m2/min (40U) during the second half of a 6-hour intravenous infusion of a BCAA mixture (i.e., BCAA; N = 5) to stimulate plasma glucose turnover or under the same conditions without BCAA infusion (Control; N = 5). In a separate experiment, seven healthy subjects were randomly assigned to receive insulin infusion at 80 mU/m2/min (80U) in association with the above BCAA infusion (N = 4) or under the same conditions without BCAA infusion (N = 3). Plasma glucose turnover was measured prior to and during insulin infusion. Results Insulin infusion completely suppressed the endogenous glucose production (EGP) across all groups. The percent suppression of EGP was not different between Control and BCAA in either the 40U or 80U experiments (P > 0.05). Insulin infusion stimulated whole-body glucose disposal rate (GDR) across all groups. However, the increase (%) in GDR was not different [median (1st quartile – 3rd quartile)] between Control and BCAA in either the 40U ([199 (167–278) vs. 186 (94–308)] or 80 U ([491 (414–548) vs. 478 (409–857)] experiments (P > 0.05). Likewise, insulin stimulated the glucose metabolic clearance in all experiments (P < 0.05) with no differences between Control and BCAA in either of the experiments (P > 0.05). Conclusion Short-term exposure of young healthy subjects to increased plasma BCAA concentrations does not alter the insulin sensitivity of glucose metabolism. PMID:25781654

  14. Expression of Toll-Like Receptors 2 and 4 and Related Cytokines in Patients with Hepatic Cystic and Alveolar Echinococcosis

    PubMed Central

    Tuxun, Tuerhongjiang; Ma, Hai-Zhang; Apaer, Shadike; Zhang, Heng; Aierken, Amina; Li, Yu-Peng; Lin, Ren-Yong; Zhao, Jin-Ming; Zhang, Jin-Hui; Wen, Hao

    2015-01-01

    Several studies have demonstrated the important role of Toll-like receptors in various parasitic infections. This study aims to explore expression of Toll-like receptors (TLRs) and related cytokines in patients with human cystic echinococcosis (CE) and alveolar echinococcosis (AE). 78 subjects including AE group (N = 28), CE group (N = 22), and healthy controls (HC, N = 28) were enrolled in this study. The mRNA expression levels of TLR2 and TLR4 in blood and hepatic tissue and plasma levels related cytokines were detected by using ELISA. Median levels of TLR2 mRNA in AE and CE groups were significantly elevated as compared with that in healthy control group. Median levels of TLR4 expression were increased in AE and CE. Plasma concentration levels of IL-5, IL-6, and IL-10 were slightly increased in AE and CE groups compared with those in HC group with no statistical differences (p > 0.05). The IL-23 concentration levels were significantly higher in AE and CE groups than that in HC subjects with statistical significance. The increased expression of TLR2 and IL-23 might play a potential role in modulating tissue infiltrative growth of the parasite and its persistence in the human host. PMID:26635448

  15. Molecular cloning and biochemical characterization of rabbit factor XI.

    PubMed Central

    Sinha, Dipali; Marcinkiewicz, Mariola; Gailani, David; Walsh, Peter N

    2002-01-01

    Human factor XI, a plasma glycoprotein required for normal haemostasis, is a homodimer (160 kDa) formed by a single interchain disulphide bond linking the Cys-321 of each Apple 4 domain. Bovine, porcine and murine factor XI are also disulphide-linked homodimers. Rabbit factor XI, however, is an 80 kDa polypeptide on non-reducing SDS/PAGE, suggesting that rabbit factor XI exists and functions physiologically either as a monomer, as does prekallikrein, a structural homologue to factor XI, or as a non-covalent homodimer. We have investigated the structure and function of rabbit factor XI to gain insight into the relation between homodimeric structure and factor XI function. Characterization of the cDNA sequence of rabbit factor XI and its amino acid translation revealed that in the rabbit protein a His residue replaces the Cys-321 that forms the interchain disulphide linkage in human factor XI, explaining why rabbit factor XI is a monomer in non-reducing SDS/PAGE. On size-exclusion chromatography, however, purified plasma rabbit factor XI, like the human protein and unlike prekallikrein, eluted as a dimer, demonstrating that rabbit factor XI circulates as a non-covalent dimer. In functional assays rabbit factor XI and human factor XI behaved similarly. Both monomeric and dimeric factor XI were detected in extracts of cells expressing rabbit factor XI. We conclude that the failure of rabbit factor XI to form a covalent homodimer due to the replacement of Cys-321 with His does not impair its functional activity because it exists in plasma as a non-covalent homodimer and homodimerization is an intracellular process. PMID:12084014

  16. Quantitative In Vitro Assessment of Liposome Stability and Drug Transfer Employing Asymmetrical Flow Field-Flow Fractionation (AF4).

    PubMed

    Holzschuh, Stephan; Kaeß, Kathrin; Fahr, Alfred; Decker, Christiane

    2016-04-01

    In the present study we introduce an efficient approach for a size-based separation of liposomes from plasma proteins employing AF4. We investigated vesicle stability and release behavior of the strongly lipophilic drug temoporfin from liposomes in human plasma for various incubation times at 37°C. We used the radioactive tracer cholesteryl oleyl ether (COE) or dipalmitoyl-phosphocholine (DPPC) as lipid markers and (14)C-labeled temoporfin. First, both lipid labels were examined for their suitability as liposome markers. Furthermore, the influence of plasma origin on liposome stability and drug transfer was investigated. The effect of membrane fluidity and PEGylation on vesicle stability and drug release characteristics was also analyzed. Surprisingly, we observed an enzymatic transfer of (3)H-COE to lipoproteins due to the cholesterol ester transfer protein (CETP) in human plasma in dependence on membrane rigidity and were able to inhibit this transfer by plasma preincubation with the CETP inhibitor torcetrapib. This effect was not seen when liposomes were incubated in rat plasma. DPPC labels suffered from hydrolysis effects during preparation and/or storage. Fluid liposomes were less stable in human plasma than their PEGylated analogues or a rigid formulation. In contrast, the transfer of the incorporated drug to lipoproteins was higher for the rigid formulations. The observed effects render COE-labels questionable for in vivo studies using CEPT-rich species. Here, choline labelled (14)C-DPPC was found to be the most promising alternative. Bilayer composition has a high influence on stability and drug release of a liposomal formulation in human plasma.

  17. Validation of a method for the determination of zolpidem in human plasma using LC with fluorescence detection.

    PubMed

    Ring, P R; Bostick, J M

    2000-04-01

    A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.

  18. Plasma Hypoxanthine-Guanine Phosphoribosyl Transferase Activity in Bottlenose Dolphins Contributes to Avoiding Accumulation of Non-recyclable Purines

    PubMed Central

    López-Cruz, Roberto I.; Crocker, Daniel E.; Gaxiola-Robles, Ramón; Bernal, Jaime A.; Real-Valle, Roberto A.; Lugo-Lugo, Orlando; Zenteno-Savín, Tania

    2016-01-01

    Marine mammals are exposed to ischemia/reperfusion and hypoxia/reoxygenation during diving. During oxygen deprivation, adenosine triphosphate (ATP) breakdown implies purine metabolite accumulation, which in humans is associated with pathological conditions. Purine recycling in seals increases in response to prolonged fasting and ischemia. Concentrations of metabolites and activities of key enzymes in purine metabolism were examined in plasma and red blood cells from bottlenose dolphins (Tursiops truncatus) and humans. Hypoxanthine and inosine monophosphate concentrations were higher in plasma from dolphins than humans. Plasma hypoxanthine-guanine phosphoribosyl transferase (HGPRT) activity in dolphins suggests an elevated purine recycling rate, and a mechanism for avoiding accumulation of non-recyclable purines (xanthine and uric acid). Red blood cell concentrations of hypoxanthine, adenosine diphosphate, ATP and guanosine triphosphate were lower in dolphins than in humans; adenosine monophosphate and nicotinamide adenine dinucleotide concentrations were higher in dolphins. HGPRT activity in red blood cells was higher in humans than in dolphins. The lower concentrations of purine catabolism and recycling by-products in plasma from dolphins could be beneficial in providing substrates for recovery of ATP depleted during diving or vigorous swimming. These results suggest that purine salvage in dolphins could be a mechanism for delivering nucleotide precursors to tissues with high ATP and guanosine triphosphate requirements. PMID:27375492

  19. Plasma Hypoxanthine-Guanine Phosphoribosyl Transferase Activity in Bottlenose Dolphins Contributes to Avoiding Accumulation of Non-recyclable Purines.

    PubMed

    López-Cruz, Roberto I; Crocker, Daniel E; Gaxiola-Robles, Ramón; Bernal, Jaime A; Real-Valle, Roberto A; Lugo-Lugo, Orlando; Zenteno-Savín, Tania

    2016-01-01

    Marine mammals are exposed to ischemia/reperfusion and hypoxia/reoxygenation during diving. During oxygen deprivation, adenosine triphosphate (ATP) breakdown implies purine metabolite accumulation, which in humans is associated with pathological conditions. Purine recycling in seals increases in response to prolonged fasting and ischemia. Concentrations of metabolites and activities of key enzymes in purine metabolism were examined in plasma and red blood cells from bottlenose dolphins (Tursiops truncatus) and humans. Hypoxanthine and inosine monophosphate concentrations were higher in plasma from dolphins than humans. Plasma hypoxanthine-guanine phosphoribosyl transferase (HGPRT) activity in dolphins suggests an elevated purine recycling rate, and a mechanism for avoiding accumulation of non-recyclable purines (xanthine and uric acid). Red blood cell concentrations of hypoxanthine, adenosine diphosphate, ATP and guanosine triphosphate were lower in dolphins than in humans; adenosine monophosphate and nicotinamide adenine dinucleotide concentrations were higher in dolphins. HGPRT activity in red blood cells was higher in humans than in dolphins. The lower concentrations of purine catabolism and recycling by-products in plasma from dolphins could be beneficial in providing substrates for recovery of ATP depleted during diving or vigorous swimming. These results suggest that purine salvage in dolphins could be a mechanism for delivering nucleotide precursors to tissues with high ATP and guanosine triphosphate requirements.

  20. PHOS-Select Iron Affinity beads enrich peptides for detection of organophosphorus adducts on albumin

    PubMed Central

    Jiang, Wei; Dubrovskii, Yaroslav A; Podolskaya, Ekaterina P; Murashko, Ekaterina A; Babakov, Vladimir; Nachon, Florian; Masson, Patrick; Schopfer, Lawrence M; Lockridge, Oksana

    2013-01-01

    Albumin is covalently modified by organophosphorus toxicants (OP) on tyrosine 411, but less than 1% of albumin is modified in humans by lethal OP doses that inhibit 95% of plasma butyrylcholinesterase. A method that enriches OP-modified albumin peptides could aid analysis of low dose exposures. Soman or chlorpyrifos oxon treated human plasma was digested with pepsin. Albumin peptides were enriched by binding to Fe3+ beads at pH 11 and eluted with pH 2.6 buffer. Similarly, mouse and guinea pig albumin modified by chlorpyrifos oxon were digested with pepsin and enriched by binding to Fe3+ beads. Peptides were identified by MALDI-TOF/TOF mass spectrometry. PHOS-select Iron Affinity beads specifically enriched albumin peptides VRY411TKKVPQVST and LVRY411TKKVPQVST in a pepsin digest of human plasma. The unmodified as well as OP-modified peptides bound to the beads. The binding capacity of 500 μl beads was the pepsin digest of 2.1 μL human plasma. The limit of detection was 0.2% of OP-modified albumin peptide in 0.43 μL plasma. Enrichment of OP-modified albumin peptides by binding to Fe3+ beads is a method with potential application to diagnosis of OP pesticide and nerve agent exposure in humans, mice, and guinea pigs. PMID:24187955

  1. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode.

    PubMed

    Sugimoto, Hiroshi; Kakehi, Masaaki; Satomi, Yoshinori; Kamiguchi, Hidenori; Jinno, Fumihiro

    2015-10-01

    We developed a highly sensitive and specific high-performance liquid chromatography with tandem mass spectrometry method with an atmospheric pressure chemical ionization interface to determine 24S-hydroxycholesterol, a major metabolite of cholesterol formed by cytochrome P450 family 46A1, in human plasma without any derivatization step. Phosphate buffered saline including 1% Tween 80 was used as the surrogate matrix for preparation of calibration curves and quality control samples. The saponification process to convert esterified 24S-hydroxycholesterol to free sterols was optimized, followed by liquid-liquid extraction using hexane. Chromatographic separation of 24S-hydroxycholesterol from other isobaric endogenous oxysterols was successfully achieved with gradient mobile phase comprised of 0.1% propionic acid and acetonitrile using L-column2 ODS (2 μm, 2.1 mm id × 150 mm). This assay was capable of determining 24S-hydroxycholesterol in human plasma (200 μL) ranging from 1 to 100 ng/mL with acceptable intra- and inter-day precision and accuracy. The potential risk of in vitro formation of 24S-hydroxycholesterol by oxidation from endogenous cholesterol in human plasma was found to be negligible. The stability of 24S-hydroxycholesterol in relevant solvents and human plasma was confirmed. This method was successfully applied to quantify the plasma concentrations of 24S-hydroxycholesterol in male and female volunteers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Characterization of human plasma proteome dynamics using deuterium oxide.

    PubMed

    Wang, Ding; Liem, David A; Lau, Edward; Ng, Dominic C M; Bleakley, Brian J; Cadeiras, Martin; Deng, Mario C; Lam, Maggie P Y; Ping, Peipei

    2014-08-01

    High-throughput quantification of human protein turnover via in vivo administration of deuterium oxide ((2) H2 O) is a powerful new approach to examine potential disease mechanisms. Its immediate clinical translation is contingent upon characterizations of the safety and hemodynamic effects of in vivo administration of (2) H2 O to human subjects. We recruited ten healthy human subjects with a broad demographic variety to evaluate the safety, feasibility, efficacy, and reproducibility of (2) H2 O intake for studying protein dynamics. We designed a protocol where each subject orally consumed weight-adjusted doses of 70% (2) H2 O daily for 14 days to enrich body water and proteins with deuterium. Plasma proteome dynamics was measured using a high-resolution MS method we recently developed. This protocol was successfully applied in ten human subjects to characterize the endogenous turnover rates of 542 human plasma proteins, the largest such human dataset to-date. Throughout the study, we did not detect physiological effects or signs of discomfort from (2) H2 O consumption. Our investigation supports the utility of a (2) H2 O intake protocol that is safe, accessible, and effective for clinical investigations of large-scale human protein turnover dynamics. This workflow shows promising clinical translational value for examining plasma protein dynamics in human diseases. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Characterization of human plasma proteome dynamics using deuterium oxide

    PubMed Central

    Wang, Ding; Liem, David A; Lau, Edward; Ng, Dominic CM; Bleakley, Brian J; Cadeiras, Martin; Deng, Mario C; Lam, Maggie PY; Ping, Peipei

    2016-01-01

    Purpose High-throughput quantification of human protein turnover via in vivo administration of deuterium oxide (2H2O) is a powerful new approach to examine potential disease mechanisms. Its immediate clinical translation is contingent upon characterizations of the safety and hemodynamic effects of in vivo administration of 2H2O to human subjects. Experimental design We recruited 10 healthy human subjects with a broad demographic variety to evaluate the safety, feasibility, efficacy, and reproducibility of 2H2O intake for studying protein dynamics. We designed a protocol where each subject orally consumed weight-adjusted doses of 70% 2H2O daily for 14 days to enrich body water and proteins with deuterium. Plasma proteome dynamics was measured using a high-resolution MS method we recently developed. Results This protocol was successfully applied in 10 human subjects to characterize the endogenous turnover rates of 542 human plasma proteins, the largest such human dataset to-date. Throughout the study, we did not detect physiological effects or signs of discomfort from 2H2O consumption. Conclusions and clinical relevance Our investigation supports the utility of a 2H2O intake protocol that is safe, accessible, and effective for clinical investigations of large-scale human protein turnover dynamics. This workflow shows promising clinical translational value for examining plasma protein dynamics in human diseases. PMID:24946186

  4. Major surgical trauma induces proteolysis of insulin-like growth factor binding protein-3 in transgenic mice and is associated with a rapid increase in circulating levels of matrix metalloproteinase-9.

    PubMed

    Belizon, A; Kirman, I; Balik, E; Karten, M; Jain, S; Whelan, R L

    2007-04-01

    The authors previously demonstrated a significant decrease in plasma levels of intact insulin-like growth factor binding protein-3 (IGFBP-3) after major open but not after laparoscopic-assisted surgery in humans. They postulated that this decrease may have an effect on postoperative tumor growth. It also has been shown that plasma levels of matrix metalloproteinase-9 (MMP-9), a protease capable of degrading IGFBP-3, are transiently increased after open colectomy in humans. The authors aimed to develop an animal model that would allow further study of the effect that surgical trauma has on plasma levels IGFBP-3 and MMP-9. In addition, they set out to assess the concentration of MMP-9 in circulating monocytes before and after surgery. The 30 mice included in this study were divided into three groups: sham laparotomy, carbon dioxide (CO2) pneumoperitoneum, and anesthesia control. All mice were IGFBP-3 transgenics (overexpressing human IGFBP-3) on a CD1 background. The mice were anesthetized using ketamine and xylazine. Blood was drawn retroorbitally 48 h before the procedure. The duration of the procedure was 30 min. The animals were killed 24 h postoperatively and blood was drawn. Intact IGFBP-3 levels were measured using a combination of Western blot analysis and enzyme-linked immunoassay (ELISA) at the two time points: before and after the operation. Plasma and peripheral blood mononuclear cell levels of MMP-9 were measured at each time point using zymography. Mononuclear cell lysates were used to determine intracellular MMP-9 levels. Plasma levels of intact IGFBP-3 were significantly lower than preoperative levels after sham laparotomy. A mean decrease of 76.6% was noted (p < 0.05). Zymography demonstrated significantly higher plasma MMP-9-related proteolytic activity than observed preoperatively after sham laparotomy (78.5 vs 42.3 Relative Units [RU]; p < 0.05). In the pneumoperitoneum group, no significant decrease was found between the pre- and postoperative levels of intact IGFBP-3. A nonsignificant increase in MMP-9 was noted after CO2 pneumoperitoneum (38 RU preoperatively vs. 46.4 RU postoperatively; p > 0.05). The anesthesia control group did not demonstrate a significant change in either circulating intact IGFBP-3 levels or MMP-9 levels. Mononuclear intracellular levels of MMP-9 were significantly lower after laparotomy than the preoperative levels (3 vs 37 RU). The postprocedure intracellular levels of MMP-9 were not significantly decreased in the pneumoperitoneum or anesthesia control group. Plasma levels of intact IGFBP-3, a cell growth regulating factor, were found to be decreased significantly after laparotomy. This decrease was not seen after pneumoperitoneum. Depletion of intact IGFBP-3 after laparotomy correlated with a rapid release of MMP-9 from mononuclear cells and an increase in circulating plasma MMP-9 levels. Matrix metalloproteinase-9 may play an important role in IGFBP-3 proteolysis after surgical trauma. Furthermore, circulating mononuclear cells are one source of MMP-9 after surgery. Finally, the model used reproduces events in humans after surgery, and thus should permit further study on the mechanism of IGFBP-3 proteolysis after surgical trauma.

  5. Chemopreventive efficacy and pharmacokinetics of curcumin in the min/+ mouse, a model of familial adenomatous polyposis.

    PubMed

    Perkins, Sarah; Verschoyle, Richard D; Hill, Kirsti; Parveen, Ifat; Threadgill, Michael D; Sharma, Ricky A; Williams, Marion L; Steward, William P; Gescher, Andreas J

    2002-06-01

    Curcumin, the major yellow pigment in turmeric, prevents the development of adenomas in the intestinal tract of the C57Bl/6J Min/+ mouse, a model of human familial APC. To aid the rational development of curcumin as a colorectal cancer-preventive agent, we explored the link between its chemopreventive potency in the Min/+ mouse and levels of drug and metabolites in target tissue and plasma. Mice received dietary curcumin for 15 weeks, after which adenomas were enumerated. Levels of curcumin and metabolites were determined by high-performance liquid chromatography in plasma, tissues, and feces of mice after either long-term ingestion of dietary curcumin or a single dose of [(14)C]curcumin (100 mg/kg) via the i.p. route. Whereas curcumin at 0.1% in the diet was without effect, at 0.2 and 0.5%, it reduced adenoma multiplicity by 39 and 40%, respectively, compared with untreated mice. Hematocrit values in untreated Min/+ mice were drastically reduced compared with those in wild-type C57Bl/6J mice. Dietary curcumin partially restored the suppressed hematocrit. Traces of curcumin were detected in the plasma. Its concentration in the small intestinal mucosa, between 39 and 240 nmol/g of tissue, reflects differences in dietary concentration. [(14)C]Curcumin disappeared rapidly from tissues and plasma within 2-8 h after dosing. Curcumin may be useful in the chemoprevention of human intestinal malignancies related to Apc mutations. The comparison of dose, resulting curcumin levels in the intestinal tract, and chemopreventive potency suggests tentatively that a daily dose of 1.6 g of curcumin is required for efficacy in humans. A clear advantage of curcumin over nonsteroidal anti-inflammatory drugs is its ability to decrease intestinal bleeding linked to adenoma maturation.

  6. Fasting plasma zeaxanthin response to Fructus barbarum L. (wolfberry; Kei Tze) in a food-based human supplementation trial.

    PubMed

    Cheng, Chung Yuen; Chung, Wai Yuen; Szeto, Yim Tong; Benzie, Iris F F

    2005-01-01

    Age-related macular degeneration (AMD) is a common disorder that causes irreversible loss of central vision. Increased intake of foods containing zeaxanthin may be effective in preventing AMD because the macula accumulates zeaxanthin and lutein, oxygenated carotenoids with antioxidant and blue light-absorbing properties. Lycium barbarum L. is a small red berry known as Fructus lycii and wolfberry in the West, and Kei Tze and Gou Qi Zi in Asia. Wolfberry is rich in zeaxanthin dipalmitate, and is valued in Chinese culture for being good for vision. The aim of this study, which was a single-blinded, placebo-controlled, human intervention trial of parallel design, was to provide data on how fasting plasma zeaxanthin concentration changes as a result of dietary supplementation with whole wolfberries. Fasting blood was collected from healthy, consenting subjects; fourteen subjects took 15 g/d wolfberry (estimated to contain almost 3 mg zeaxanthin) for 28 d. Repeat fasting blood was collected on day 29. Age- and sex-matched controls (n 13) took no wolfberry. Responses in the two groups were compared using the Mann-Whitney test. After supplementation, plasma zeaxanthin increased 2.5-fold: mean values on day 1 and 29 were 0.038 (sem 0.003) and 0.096 (sem 0.009) micromol/l (P<0.01), respectively, for the supplementation group; and 0.038 (sem 0.003) and 0.043 (sem 0.003) micromol/l (P>0.05), respectively, for the control group. This human supplementation trial shows that zeaxanthin in whole wolfberries is bioavailable and that intake of a modest daily amount markedly increases fasting plasma zeaxanthin levels. These new data will support further study of dietary strategies to maintain macular pigment density.

  7. Differential lipid profile and hormonal response in type 2 diabetes by exogenous insulin aspart versus the insulin secretagogue repaglinide, at the same glycemic control.

    PubMed

    Chisalita, Simona I; Lindström, Torbjörn; Eson Jennersjö, Pär; Paulsson, Johan F; Westermark, Gunilla T; Olsson, Anders G; Arnqvist, Hans J

    2009-03-01

    Our aim was to study, at the same glycemic control, how treatment with either the insulin secretagogue repaglinide or exogenous insulin aspart affects endogenous insulin secretion, plasma insulin and IAPP (islet amyloid polypeptide) levels, GH-IGF (growth hormone-insulin-like growth factor) axis and plasma lipoprotein concentrations in patients with type 2 diabetes. Five patients, age 65.0+/-4.1 years (mean+/-SE), body weight 82.5+/-5.0 kg, BMI (body mass index) 27.7+/-1.5 kg/m(2) were treated for 10 weeks with repaglinide or insulin aspart in a randomized, cross-over study. At the end of each treatment a 24-h metabolic profile was performed. Blood glucose, C-peptide, free human insulin, free total (human and analogue) insulin, proinsulin, IAPP, IGF-I, IGFBP-1 (IGF binding protein-1), GHBP (growth hormone binding protein) and plasma lipoprotein concentrations were measured. Similar 24-h blood glucose profiles were obtained with repaglinide and insulin aspart treatment. During the repaglinide treatment, the meal related peaks of C-peptide and free human insulin were about twofold higher than during treatment with insulin aspart. Proinsulin, GHBP were higher and IAPP levels tended to be higher during repaglinide compared to insulin aspart. Postprandial plasma total cholesterol, triglycerides and apolipoprotein B concentrations were higher on repaglinide than on insulin aspart treatment. Our results show that, at the same glycemic control, treatment with exogenous insulin aspart in comparison with the insulin secretagogue repaglinide result in a lower endogenous insulin secretion, and a tendency towards a less atherogenic postprandial lipid profile.

  8. Age- and gender-related alteration in plasma advanced oxidation protein products (AOPP) and glycosaminoglycan (GAG) concentrations in physiological ageing.

    PubMed

    Komosinska-Vassev, Katarzyna; Olczyk, Pawel; Winsz-Szczotka, Katarzyna; Kuznik-Trocha, Kornelia; Klimek, Katarzyna; Olczyk, Krystyna

    2012-02-13

    The authors studied the role of increased oxidative stress in the development of oxidative protein damage and extracellular matrix (ECM) components in ageing. The age- and gender-associated disturbances in connective tissue metabolism were evaluated by the plasma chondroitin sulphated glycosaminoglycans (CS-GAG) and non-sulphated GAG-hyaluronan (HA) measurements. Plasma concentration of advanced oxidation protein products (AOPP) was analysed in order to assess oxidative protein damage and evaluate the possible deleterious role of oxidative phenomenon on tissue proteoglycans' metabolism during the physiological ageing process. Sulphated and non-sulphated GAGs as well as AOPP were quantified in plasma samples from 177 healthy volunteers. A linear age-related decline of plasma CS-GAG level was found in this study (r=-0.46; p<0.05). In contrast, HA concentrations rise gradually with age (r=0.44; p<0.05) in plasma samples. For both ECM components, the observed differences were not gender-specific. A strong age-dependent relationship has been shown in regard to AOPP. AOPP levels significantly increased with age (r=0.63; p<0.05), equally strongly in both men (r=0.69; p<0.05) and women (r=0.57; p<0.05) during physiological ageing. A significant correlation was found between the concentrations of AOPP and both CS-GAG (r=-0.31; p<0.05) and HA (r=0.33; p<0.05). Proceeding with age changes in the ECM are reflected by CS-GAG and HA plasma levels. Strong correlations between AOPP and ECM components indicate that oxidative stress targets protein and non-protein components of the connective tissue matrix during human ageing.

  9. Nonclinical and clinical pharmacological characterization of the potent and selective cathepsin K inhibitor MIV-711.

    PubMed

    Lindström, Erik; Rizoska, Biljana; Henderson, Ian; Terelius, Ylva; Jerling, Markus; Edenius, Charlotte; Grabowska, Urszula

    2018-05-09

    Cathepsin K is an attractive therapeutic target for diseases in which bone resorption is excessive such as osteoporosis and osteoarthritis (OA). The current paper characterized the pharmacological profile of the potent and selective cathepsin K inhibitor, MIV-711, in vitro and in cynomolgus monkeys, and assessed translation to human based on a single dose clinical study in man. The potency and selectivity of MIV-711 were assessed in vitro using recombinant enzyme assays and differentiated human osteoclasts. MIV-711 was administered to healthy cynomolgus monkeys (3-30 µmol/kg, p.o.). Plasma levels of MIV-711 and the bone resorption biomarker CTX-I were measured after single dose experiments, and urine levels of CTX-I, NTX-I and CTX-II biomarkers were measured after repeat dose experiments. The safety, pharmacokinetics and pharmacodynamics (serum CTX-I) of MIV-711 were assessed in human healthy subjects after single ascending doses from 20 to 600 mg. MIV-711 was a potent inhibitor of human cathepsin K (K i : 0.98 nmol/L) with > 1300-fold selectivity towards other human cathepsins. MIV-711 inhibited human osteoclast-mediated bone resorption with an IC 50 value of 43 nmol/L. Single oral doses of MIV-711 to monkeys reduced plasma levels of CTX-I in a dose-dependent fashion by up to 57% at trough. The effect on CTX-I was linearly correlated to the plasma exposure of MIV-711, while the efficacy duration outlasted plasma exposure. Repeat oral dosing with MIV-711 also reduced urinary levels of the bone resorption biomarkers CTX-I (by 93%) and NTX-I (by 71%) and the cartilage degradation biomarker CTX-II (by 71%). MIV-711 was safe and well-tolerated when given as single ascending doses to healthy subjects. MIV-711 reduced serum CTX-I levels in a dose-dependent manner by up to 79% at trough. The relationship between MIV-711 exposure and effects on these biomarkers in humans was virtually identical when compared to the corresponding monkey data. MIV-711 is a potent and selective cathepsin K inhibitor with dose-dependent effects on biomarkers of bone and cartilage degradation in monkey and human. Taken together, MIV-711 shows promise for the treatment of bone and cartilage related disorders in humans, such as OA. Trial Registration EudraCT number 2011-003024-12, registered on June 22nd 2011.

  10. Profound differences between humans and rodents in the ability to concentrate salivary nitrate: Implications for translational research.

    PubMed

    Montenegro, Marcelo F; Sundqvist, Michaela L; Nihlén, Carina; Hezel, Michael; Carlström, Mattias; Weitzberg, Eddie; Lundberg, Jon O

    2016-12-01

    In humans dietary circulating nitrate accumulates rapidly in saliva through active transport in the salivary glands. By this mechanism resulting salivary nitrate concentrations are 10-20 times higher than in plasma. In the oral cavity nitrate is reduced by commensal bacteria to nitrite, which is subsequently swallowed and further metabolized to nitric oxide (NO) and other bioactive nitrogen oxides in blood and tissues. This entero-salivary circulation of nitrate is central in the various NO-like effects observed after ingestion of inorganic nitrate. The very same system has also been the focus of toxicologists studying potential carcinogenic effects of nitrite-dependent nitrosamine formation. Whether active transport of nitrate and accumulation in saliva occurs also in rodents is not entirely clear. Here we measured salivary and plasma levels of nitrate and nitrite in humans, rats and mice after administration of a standardized dose of nitrate. After oral (humans) or intraperitoneal (rodents) sodium nitrate administration (0.1mmol/kg), plasma nitrate levels increased markedly reaching ~300µM in all three species. In humans ingestion of nitrate was followed by a rapid increase in salivary nitrate to >6000µM, ie 20 times higher than those found in plasma. In contrast, in rats and mice salivary nitrate concentrations never exceeded the levels in plasma. Nitrite levels in saliva and plasma followed a similar pattern, ie marked increases in humans but modest elevations in rodents. In mice there was also no accumulation of nitrate in the salivary glands as measured directly in whole glands obtained after acute administration of nitrate. This study suggests that in contrast to humans, rats and mice do not actively concentrate circulating nitrate in saliva. These apparent species differences should be taken into consideration when studying the nitrate-nitrite-nitric oxide pathway in rodents, when calculating doses, exploring physiological, therapeutic and toxicological effects and comparing with human data. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Culture Medium Supplements Derived from Human Platelet and Plasma: Cell Commitment and Proliferation Support

    PubMed Central

    Muraglia, Anita; Nguyen, Van Thi; Nardini, Marta; Mogni, Massimo; Coviello, Domenico; Dozin, Beatrice; Strada, Paolo; Baldelli, Ilaria; Formica, Matteo; Cancedda, Ranieri; Mastrogiacomo, Maddalena

    2017-01-01

    Present cell culture medium supplements, in most cases based on animal sera, are not fully satisfactory especially for the in vitro expansion of cells intended for human cell therapy. This paper refers to (i) an heparin-free human platelet lysate (PL) devoid of serum or plasma components (v-PL) and (ii) an heparin-free human serum derived from plasma devoid of PL components (Pl-s) and to their use as single components or in combination in primary or cell line cultures. Human mesenchymal stem cells (MSC) primary cultures were obtained from adipose tissue, bone marrow, and umbilical cord. Human chondrocytes were obtained from articular cartilage biopsies. In general, MSC expanded in the presence of Pl-s alone showed a low or no proliferation in comparison to cells grown with the combination of Pl-s and v-PL. Confluent, growth-arrested cells, either human MSC or human articular chondrocytes, treated with v-PL resumed proliferation, whereas control cultures, not supplemented with v-PL, remained quiescent and did not proliferate. Interestingly, signal transduction pathways distinctive of proliferation were activated also in cells treated with v-PL in the absence of serum, when cell proliferation did not occur, indicating that v-PL could induce the cell re-entry in the cell cycle (cell commitment), but the presence of serum proteins was an absolute requirement for cell proliferation to happen. Indeed, Pl-s alone supported cell growth in constitutively activated cell lines (U-937, HeLa, HaCaT, and V-79) regardless of the co-presence of v-PL. Plasma- and plasma-derived serum were equally able to sustain cell proliferation although, for cells cultured in adhesion, the Pl-s was more efficient than the plasma from which it was derived. In conclusion, the cells expanded in the presence of the new additives maintained their differentiation potential and did not show alterations in their karyotype. PMID:29209609

  12. Simultaneous stable-isotope dilution GC-MS measurement of homoarginine, guanidinoacetate and their common precursor arginine in plasma and their interrelationships in healthy and diseased humans.

    PubMed

    Hanff, Erik; Kayacelebi, Arslan Arinc; Yanchev, Georgi Radoslavov; Maassen, Norbert; Haghikia, Arash; Tsikas, Dimitrios

    2016-03-01

    Low concentrations of L-homoarginine (hArg) in plasma or serum and urine have recently emerged as a novel cardiovascular risk factor. Previously, we reported gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) methods for the quantitative determination of hArg and Arg in plasma, serum, urine and other biological samples. In these methods, plasma and serum are ultrafiltered by means of commercially available cartridges (10 kDa), and 10-µL ultrafiltrate aliquots are subjected to a two-step derivatization procedure, yielding the methyl ester tri(N-pentafluoropropionyl) derivatives. De novo prepared trideuteromethyl ester hArg (d3Me-hArg) was used as an internal standard. To make the hArg analysis in plasma more convenient, straightforward and cheaper we performed two key modifications: (1) precipitation of plasma proteins by methanol and (2) use of newly prepared and d3Me-hArg as the internal standard. The method was validated and used for the quantitative determination of hArg in human plasma by GC-MS after electron-capture negative-ion chemical ionization (ECNICI) using methane as the reactant gas. Intra-assay accuracy (recovery) and imprecision (relative standard deviation) were within generally accepted ranges (93-109 and 2.3-10 %, respectively). Furthermore, we extended the applicability of this method to guanidinoacetate (GAA). This is of particular importance because hArg and GAA are produced from Arg by the catalytic action of arginine:glycine amidinotransferase (AGAT) also known as glycine:arginine transamidinase (GATM). Using this method, we quantitated simultaneously hArg, Arg and GAA in the selected-ion monitoring mode in 10-µL aliquots of plasma. In plasma samples of 17 non-medicated healthy young men, the concentration of hArg, GAA and Arg was determined to be (mean ± SD) 1.7 ± 0.6, 2.6 ± 0.8, 91 ± 29 µM, respectively. The correlation between hArg and Arg was borderline (r = 0.47, P = 0.06). GAA strongly correlated with Arg (r = 0.82, P < 0.0001) but did not correlate with hArg (r = 0.17, P = 0.52). The plasma concentrations of hArg, GAA and Arg measured in 9 patients suffering from stroke or transitory ischemic attack were 1.8 ± 0.6, 2.7 ± 0.4 and 82 ± 17 µM. The ratio values of the hArg, GAA and Arg concentrations measured after removal of plasma proteins by methanol precipitation or ultrafiltration were 0.94 ± 0.1, 0.94 ± 0.08, and 0.88 ± 0.07, respectively. Simultaneous measurement of hArg and GAA in human plasma may allow assessment of AGAT activity in vivo with respect both to GAA and to hArg and their relationship in health, disease, nutrition and pharmacotherapy.

  13. Transplantation of human dental pulp-derived stem cells protects against heatstroke in mice.

    PubMed

    Tseng, Ling-Shu; Chen, Sheng-Hsien; Lin, Mao-Tsun; Lin, Ying-Chu

    2015-01-01

    Stem cells from human exfoliated deciduous tooth pulp (SHED) is a promising approach for the treatment of stroke and spinal cord injury. In this study, we investigated the therapeutic effects of SHED for the treatment of multiple organ (including brain, particularly hypothalamus) injury in heatstroke mice. ICR male mice were exposed to whole body heating (WBH; 41.2°C, relative humidity 50-55%, for 1 h) and then returned to normal room temperature (26°C). We observed that intravenous administration of SHED immediately post-WBH exhibited the following therapeutic benefits for recovery after heatstroke: (a) inhibition of WBH-induced neurologic and thermoregulatory deficits; (b) reduction of WBH-induced ischemia, hypoxia, and oxidative damage to the brain (particularly the hypothalamus); (c) attenuation of WBH-induced increased plasma levels of systemic inflammatory response molecules, such as tumor necrosis factor-α and intercellular adhesion molecule-1; (d) improvement of WBH-induced hypothalamo-pituitary-adrenocortical (HPA) axis activity (as reflected by enhanced plasma levels of both adrenocorticotrophic hormone and corticosterone); and (e) attenuation of WBH-induced multiple organ apoptosis as well as lethality. In conclusion, post-WBH treatment with SHED reduced induction of proinflammatory cytokines and oxidative radicals, enhanced plasma induction of both adrenocorticotrophic hormone and corticosterone, and improved lethality in mouse heatstroke. The protective effect of SHED may be related to a decreased inflammatory response, decreased oxidative stress, and an increased HPA axis activity following the WBH injury.

  14. Quantitation of quinapril in human plasma by matrix-assisted laser desorption ionization time-of-flight mass spectrometry with quinolone matrix additives.

    PubMed

    Lu, Chi-Yu; Liu, Fei-Tsui; Feng, Chia-Hsien

    2011-09-15

    The renin-angiotensin-aldosterone system (RAAS) is an essential body fluid maintenance system that controls pressure in the human body. The conversion of angiotensin I to angiotensin II by angiotensin-converting enzyme (ACE) is a key process in the RAAS because angiotensin II causes the vasoconstriction association with hypertension. Because of its effectiveness as an ACE blocker, quinipril is widely used for clinical treatment of hypertension and chronic congestive heart failure(.) Matrix-assisted laser desorption/ionization coupled with time-of-flight analyzer (MALDI-TOF) is a high throughput instrument for biological sample analysis. This study developed a micro-scale approach for using MALDI-TOF to detect quinapril in biological samples. A micro-liquid-liquid-extraction strategy combined with ion-pair interaction successfully extracted quinapril from aqueous layer to organic layer. Quinolones were then used as matrix additives to suppress undesired substances in plasma produce signals. Several factors affecting extraction efficiency were investigated in a biosample with a volume of only 10 μL. This method is successful to monitor quinapril in the clinical therapeutic range. The proposed method proved effective for monitoring the trace amounts of quinapril typically used for clinical therapy. The relative standard deviation (R.S.D.) and relative error (R.E.) used for evaluating within- and between-day assays of quinapril in plasma consistently remained below 15%. Copyright © 2011. Published by Elsevier B.V.

  15. Induction of proliferation of basal epidermal keratinocytes by cold atmospheric-pressure plasma.

    PubMed

    Hasse, S; Duong Tran, T; Hahn, O; Kindler, S; Metelmann, H-R; von Woedtke, T; Masur, K

    2016-03-01

    Over the past few decades, new cold plasma sources have been developed that have the great advantage of operating at atmospheric pressure and at temperatures tolerable by biological material. New applications for these have emerged, especially in the field of dermatology. Recently it was demonstrated that cold atmospheric-pressure plasma positively influences healing of chronic wounds. The potential of cold plasma lies in its capacity to reduce bacterial load in the wound while at the same time stimulating skin cells and therefore promoting wound closure. In recent years, there have been great advances in the understanding of the molecular mechanisms triggered by cold plasma involving signalling pathways and gene regulation in cell culture. To investigate cold plasma-induced effects in ex vivo treated human skin biopsies. Human skin tissue was exposed to cold plasma for different lengths of time, and analysed by immunofluorescence with respect to DNA damage, apoptosis, proliferation and differentiation markers. After cold plasma treatment, the epidermal integrity and keratin expression pattern remained unchanged. As expected, the results revealed an increase in apoptotic cells after 3 and 5 min of treatment. Strikingly, an induction of proliferating basal keratinocytes was detected after cold plasma exposure for 1 and 3 min. As these are the cells that regenerate the epidermis, this could indeed be beneficial for wound closure. We investigated the effect of cold plasma on human skin by detecting molecules for growth and apoptosis, and found that both processes are dependent on treatment time. Therefore, this approach offers promising results for further applications of cold plasma in clinical dermatology. © 2015 British Association of Dermatologists.

  16. Uric acid is a main electron donor to peroxidases in human blood plasma.

    PubMed

    Padiglia, Alessandra; Medda, Rosaria; Longu, Silvia; Pedersen, Jens Z; Floris, Giovanni

    2002-11-01

    Peroxidases are widely distributed and have been isolated from many higher-order plants, animal tissues, yeast and microorganisms. During measurements of peroxidase activities in samples of human plasma, we noticed the presence of a compound in the plasma which was interfering with the peroxidase assay. In this paper we describe the purification and characterization of this factor, which was identified as uric acid. The procedure used to purify uric acid from plasma involved ultra-filtration of the plasma, heat denaturation, DEAE-cellulose chromatography, and high performance liquid chromatography. The lyophilized powder was tested for homogeneity using an HPLC apparatus and capillary electrophoresis. Genuine uric acid samples were used for comparison. The compound obtained by the above-reported purification procedure was identified as uric acid by spectrophotometric analysis through comparison with genuine uric acid samples. Spectrophotometric measurements indicated that uric acid was degraded by HRP in the presence of H2O2. The experimental procedures described above allowed us to isolate and identify uric acid as the component in human plasma that acts as a true substrate for peroxidases.

  17. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  18. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  19. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  20. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  1. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  2. Mechanisms and Permanence of Sequestered Pb and As in Soils: Impact on Human Bioavailability

    DTIC Science & Technology

    2016-12-01

    Human health risk assessment ICP-MS Inductively coupled plasma - mass spectrometry ICP-OES Inductively coupled plasma – optical emission spectrometry...the most common contaminants of concern exceeding risk criteria because soil ingestion is the primary human health risk driver at many DoD sites...development activities must address to realize the use of bioavailability in human health risk assessment (HHRA). Our proposal addressed three of the

  3. Identification of NaK-ATPase inhibitors in human plasma as nonesterified fatty acids and lysophospholipids.

    PubMed

    Kelly, R A; O'Hara, D S; Mitch, W E; Smith, T W

    1986-09-05

    Elevated plasma levels of factors with cardiac glycoside-like activity have been implicated in the response to volume expansion in animals and in the pathogenesis of certain human diseases. We recently described four fractions (IR1, EI1, EI2, EI3) from normal human plasma that inhibit NaK-ATPase, displace ouabain from the enzyme, and exhibit digoxin-like immunoreactivity (Kelly, R. A., O'Hara, D. S., Canessa, M. L., Mitch, W. E., and Smith, T. W. (1985) J. Biol. Chem. 260, 11396-11405). In this report, we identify the active component of these plasma fractions as long-chain nonesterified fatty acids (NEFA) and lysophospholipids. These lipids were present in fractions EI1, EI2, and EI3 in quantities sufficient to account for all of the NaK-ATPase inhibitory activity. The digoxin-like immunoreactivity in fraction IR1 could be attributed to hydrocortisone and other endogenous steroids. To explore the nature of the lipid-NaK-ATPase interactions, we examined the effects of various ATP or sodium concentrations on the NaK-ATPase activity measured in the presence of NEFA. Varying sodium did not affect the inhibition of NaK-ATPase by linoleic acid. At less than 0.15 mM ATP, linoleic acid stimulated NaK-ATPase, but at higher ATP concentrations, the enzyme was progressively inhibited. In summary, NEFA and lysophospholipids, at levels similar to those occurring in human plasma, may account for all of the NaK-ATPase inhibitory activity observed in human plasma fractions. These lipids probably do not directly regulate NaK-ATPase in vivo under normal physiologic conditions, but may alter the sodium pump in disease states characterized by abnormalities in lipid metabolism or plasma protein binding.

  4. Plasma protein binding of an antisense oligonucleotide targeting human ICAM-1 (ISIS 2302).

    PubMed

    Watanabe, Tanya A; Geary, Richard S; Levin, Arthur A

    2006-01-01

    In vitro ultrafiltration was used to determine the plasma protein-binding characteristics of phosphorothioate oligonucleotides (PS ODNs). Although there are binding data on multiple PS ODNs presented here, the focus of this research is on the protein-binding characteristics of ISIS 2302, a PS ODN targeting human intercellular adhesion molecule-1 (ICAM-1) mRNA, which is currently in clinical trials for the treatment of ulcerative colitis. ISIS 2302 was shown to be highly bound (> 97%) across species (mouse, rat, monkey, human), with the mouse having the least degree of binding. ISIS 2302 was highly bound to albumin and, to a lesser, extent alpha2-macroglobulin and had negligible binding to alpha1-acid glycoprotein. Ten shortened ODN metabolites (8, 10, and 12-19 nucleotides [nt] in length, truncated from the 3' end) were evaluated in human plasma. The degree of binding was reduced as the ODN metabolite length decreased. Three additional 20-nt (20-mer) PS ODNs (ISIS 3521, ISIS 2503, and ISIS 5132) of varying sequence but similar chemistry were evaluated. Although the tested PS ODNs were highly bound to plasma proteins, suggesting a commonality within the chemical class, these results suggested that the protein-binding characteristics in human plasma may be sequence dependent. Lastly, drug displacement studies with ISIS 2302 and other concomitant drugs with known protein-binding properties were conducted to provide information on potential drug interactions. Coadministered ISIS 2302 and other high-binding drugs evaluated in this study did not displace one another at supraclinical plasma concentrations and, thus, are not anticipated to cause any pharmacokinetic interaction in the clinic as a result of the displacement of binding to plasma proteins.

  5. Binding of [51Cr]ethylenediaminetetraacetate to proteins of human plasma.

    PubMed Central

    Babiker, M M

    1986-01-01

    Binding of [51Cr]EDTA to human plasma proteins was investigated using chemical and chromatographic techniques of separation of the proteins and protein fractions. Total plasma proteins isolated with ethanol retained 12.95 +/- 0.46% of the initial plasma activity. Proteins separated by other precipitants retained about 16% of the initial radioactivity. Globulins exhibited the highest binding capacity for [51Cr]EDTA and retained about 11.7% of the initial plasma activity following chromatographic separation. This value represents about 70% of the radioactivity bound by the total proteins of the plasma. gamma-Globulins contributed most of the binding attributed to the globulins and retained about 8.7% of the initial [51Cr]EDTA activity. The repeatedly reported underestimation of the renal glomerular filtration rate when estimated as the clearance of [51Cr]EDTA could be adequately accounted for by the extent of binding of this marker to the plasma proteins. PMID:2427701

  6. Unsuccessful detection of plant microRNAs in beer, extra virgin olive oil and human plasma after an acute ingestion of extra virgin olive oil

    USDA-ARS?s Scientific Manuscript database

    The recent description of the presence of exogenous plant microRNAs from rice in human plasma had profound implications for the interpretation of microRNAs function in human health. If validated, these results suggest that food should not be considered only as a macronutrient and micronutrient suppl...

  7. Hormones and endocrine disruptors in human seminal plasma.

    PubMed

    Hampl, R; Kubatova, J; Heracek, J; Sobotka, V; Starka, L

    2013-07-01

    Seminal plasma represents a unique environment for maturation, nutrition, and protection of male germ cells from damaging agents. It contains an array of organic as well as inorganic chemicals, encompassing a number of biologically and immunologically active compounds, including hormones. Seminal plasma contains also various pollutants transferred from outer environment known as endocrine disruptors. They interfere with hormones at the receptor level, act as inhibitors of their biosynthesis, and affect hormone regulation.In this minireview, the main groups of hormones detected in seminal plasma are summarized. Seminal gonadal steroids were investigated mostly with aim to use them as biomarkers of impaired spermatogenesis (sperm count, motility, morphology). Concentrations of hormones in the seminal plasma often differ considerably from the blood plasma levels in dependence on their origin. In some instances (dihydrotestosterone, estradiol), their informative value is higher than determination in blood.Out of peptide hormones detected in seminal plasma, peptides of transforming growth factor beta family, especially antimullerian hormone, and oligopeptides related to thyrotropin releasing hormone have the high informative value, while assessment of seminal gonadotropins and prolactin does not bring advantage over determination in blood.Though there is a large body of information about the endocrine disruptors' impact on male reproduction, especially with their potential role in decline of male reproductive functions within the last decades, there are only scarce reports on their presence in seminal plasma. Herein, the main groups of endocrine disruptors found in seminal plasma are reviewed, and the use of their determination for investigation of fertility disorders is discussed.

  8. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    PubMed

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides information about the contributions of absorptive and postabsorptive conversion to total bioefficacy if an additional sample is taken at 1 d. © 2017 American Society for Nutrition.

  9. In vitro activity and human pharmacokinetics of teicoplanin.

    PubMed Central

    Verbist, L; Tjandramaga, B; Hendrickx, B; Van Hecken, A; Van Melle, P; Verbesselt, R; Verhaegen, J; De Schepper, P J

    1984-01-01

    The in vitro activity of teicoplanin, a new antibiotic related to vancomycin, was determined against 456 gram-positive cocci. The activity of teicoplanin in comparison with that of vancomycin was similar against staphylococci but 4 to 40 times higher against enterococci and beta-hemolytic and viridans streptococci. The single-dose pharmacokinetics of teicoplanin were studied in six healthy volunteers after administration of 3 and 6 mg/kg intravenously and of 3 mg/kg intramuscularly. The kinetic parameters after both intravenous doses were very similar. The curves for concentration in plasma for the 3- and 6-mg/kg intravenous doses showed a triexponential decline with elimination half-lives of 47.3 and 44.1 h, respectively. The percentages of the doses recovered in urine (0 to 102 h) were 43.2 and 44.1%, respectively. The areas under the plasma curves were dose related: 256.5 and 520.9 micrograms/h per ml, respectively. The bioavailability of teicoplanin after injection of 3 mg/kg intramuscularly was 90%, and the peak level was 7.1 micrograms/ml. The mean levels in plasma 24 h after the 3-mg/kg doses were 2.1 and 2.3 micrograms/ml, respectively, and the mean level in plasma 24 h after the 6-mg/kg intravenous dose was 4.2 micrograms/ml. PMID:6240962

  10. Determination of amantadine in biological fluids using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection.

    PubMed

    Farajzadeh, Mir Ali; Nouri, Nina; Alizadeh Nabil, Ali Akbar

    2013-12-01

    A one-step derivatization and microextraction technique for the determination of amantadine in the human plasma and urine samples is presented. An appropriate mixture of methanol (disperser solvent), 1,2-dibromoethane (extraction solvent), and butylchloroformate (derivatization agent) is rapidly injected into samples. After centrifuging, the sedimented phase is analyzed by gas chromatography-flame ionization detection (GC-FID). The kind of extraction and disperser solvents and their volumes, amount of derivatization agent and reaction/extraction time which are effective in derivatization/dispersive liquid-liquid microextraction (DLLME) procedure are optimized. Under the optimal conditions, the enrichment factor (EF) of the target analyte was obtained to be 408 and 420, and limit of detection (LOD) 4.2 and 2.7ngmL(-1), in plasma and urine respectively. The linear range is 14-5000 and 8.7-5000ng/mL for plasma and urine, respectively (squared correlation coefficient≥0.990). The relative recoveries obtained for the spiked plasma and urine samples are between 72% and 93%. Moreover, the inter- and intra-day precisions are acceptable at all spiked concentrations (relative standard deviation <7%). Finally the method was successfully applied to determine amantadine in biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Plasma-activated medium suppresses choroidal neovascularization in mice: a new therapeutic concept for age-related macular degeneration.

    PubMed

    Ye, Fuxiang; Kaneko, Hiroki; Nagasaka, Yosuke; Ijima, Ryo; Nakamura, Kae; Nagaya, Masatoshi; Takayama, Kei; Kajiyama, Hiroaki; Senga, Takeshi; Tanaka, Hiromasa; Mizuno, Masaaki; Kikkawa, Fumitaka; Hori, Masaru; Terasaki, Hiroko

    2015-01-09

    Choroidal neovascularization (CNV) is the main pathogenesis of age-related macular degeneration (AMD), which leads to severe vision loss in many aged patients in most advanced country. CNV compromises vision via hemorrhage and retinal detachment on account of pathological neovascularization penetrating the retina. Plasma medicine represents the medical application of ionized gas "plasma" that is typically studied in the field of physical science. Here we examined the therapeutic ability of plasma-activated medium (PAM) to suppress CNV. The effect of PAM on vascularization was assessed on the basis of human retinal endothelial cell (HREC) tube formation. In mice, laser photocoagulation was performed to induce CNV (laser-CNV), followed by intravitreal injection of PAM. N-Acetylcysteine was used to examine the role of reactive oxygen species in PAM-induced CNV suppression. Fundus imaging, retinal histology examination, and electroretinography (ERG) were also performed to evaluate PAM-induced retinal toxicity. Interestingly, HREC tube formation and laser-CNV were both reduced by treatment with PAM. N-acetylcysteine only partly neutralized the PAM-induced reduction in laser-CNV. In addition, PAM injection had no effect on regular retinal vessels, nor did it show retinal toxicity in vivo. Our findings indicate the potential of PAM as a novel therapeutic agent for suppressing CNV.

  12. Fuzhengpaidu granule regulates immune activation molecules CD38 and human leukocyte antigen-D related on CD4+ and CD8+ T cells in patients with acquired immunodeficiency syndrome/human immunodeficiency virus.

    PubMed

    Jiang, Feng; Zhang, Rongxin; Gu, Zhenfang; Zhang, Huailing; Guo, Huijun; Deng, Xin; Liang, Jian

    2013-08-01

    To evaluate the effect of Fuzhengpaidu granule (FZPDG) on immune activation molecules CD38 and human leukocyte antigen-D related (HLA-DR) on CD4+ and CD8+ cells in HIV/AIDS patients, and to explore the underlying mechanism of this therapy. Plasma changes in CD3+, CD4+, CD8+, CD3 + CD4 + CD38 +, CD3 + CD4 + HLA-DR+, CD3 + CD8+CD38+, and CD3+CD8+HLA-DR+ levels in HIV/ AIDS patients treated with FZPDG for six months were examined by flow cytometry and compared with levels in healthy controls. The clinical trial included 34 outpatients with HIV/AIDS. Before treatment, plasma levels of CD38+ and HLA-DR+ on CD4/CD8 cells were higher than those in 28 health controls (P < 0.05). There were no significant changes in serum levels of CD3+, CD4+, and CD8+ T cells between pretreatment baseline versus after treatment, which were 82.85% +/- 5.41%, 14.57% +/- 10.31% and 54.55% +/- 11.43% before treatment and 79.15% +/- 8.21%, 19.96% +/- 9.58% and 56.36% +/- 11.67% after treatment, respectively (P > 0.05). Plasma levels of CD3+ CD4+CD38+ and CD3+CD4+HLA-DR+ were 2.3% +/-2.2% and 7.8% +/- 5.5% before treatment and 1.2% +/-0.8% and 2.6% +/- 1.0% after treatment, respectively. Plasma levels of CD3+CD8+CD38+ and CD3+CD8+ HLA-DR+ were 41.4% +/- 13.4% and 17.8% +/- 11.3% before treatment, which changed to 27.1% +/- 10.2% and 3.8% +/- 2.4% after treatment, respectively (P < 0.05). HIV/AIDS patients exhibited an immune activation profile following FZPDG treatment. A potential mechanism of action for FZPDG appears to lie in its ability to up-regulate CD38 and HLA-DR levels on CD4+ T cells, and down-regulate them on CD8+ cells, thereby modulating immune activation of CD4+and CD8+T cells.

  13. Application of Microchip Electrophoresis for Clinical Tests

    NASA Astrophysics Data System (ADS)

    Yatsushiro, Shouki; Kataoka, Masatoshi

    Microchip electrophoresis has recently attracted much attention in the field of nuclear acid analysis due to its high efficiency, ease of operation, low consumption of samples and reagents, and relatively low costs. In addition, the analysis has expanded to an analytical field like not only the analysis of DNA but also the analysis of RNA, the protein, the sugar chain, and the cellular function, etc. In this report, we showed that high-performance monitoring systems for human blood glucose levels and α-amylase activity in human plasma using microchip electrophoresis.

  14. Effect of Cigarette Smoking on Concentrations of Cadmium and Lead and on the Oxidative Damage in Human Spermatozoa

    NASA Astrophysics Data System (ADS)

    Kiziler, Ali Riza; Aydemir, Birsen; Onaran, Ilhan; Alici, Bülent; Özkara, Hamdi; Akyolcu, Mehmet Can

    2007-04-01

    Cigarette smoking induced a significant oxidant effect to free radical-related male infertility. Semen and blood obtained from 50 subfertile men (n=26 smokers, n=24 nonsmokers) and from 45 fertile men (n=23 smokers, n=22 nonsmokers) volunteers were examined. The levels of ROS, MDA and protein carbonyls were significantly increased in smokers subfertile men. The results indicate that Cd and Pb levels of smoking subfertile men in seminal plasma and spermatozoa could affect semen quality and oxidative damage in human sperm cells.

  15. Cys34-Cysteinylated Human Serum Albumin Is a Sensitive Plasma Marker in Oxidative Stress-Related Chronic Diseases

    PubMed Central

    Nagumo, Kohei; Tanaka, Motohiko; Chuang, Victor Tuan Giam; Setoyama, Hiroko; Watanabe, Hiroshi; Yamada, Naoyuki; Kubota, Kazuyuki; Tanaka, Motoko; Matsushita, Kazutaka; Yoshida, Akira; Jinnouchi, Hideaki; Anraku, Makoto; Kadowaki, Daisuke; Ishima, Yu; Sasaki, Yutaka; Otagiri, Masaki; Maruyama, Toru

    2014-01-01

    The degree of oxidized cysteine (Cys) 34 in human serum albumin (HSA), as determined by high performance liquid chromatography (HPLC), is correlated with oxidative stress related pathological conditions. In order to further characterize the oxidation of Cys34-HSA at the molecular level and to develop a suitable analytical method for a rapid and sensitive clinical laboratory analysis, the use of electrospray ionization time-of-flight mass spectrometer (ESI-TOFMS) was evaluated. A marked increase in the cysteinylation of Cys34 occurs in chronic liver and kidney diseases and diabetes mellitus. A significant positive correlation was observed between the Cys-Cys34-HSA fraction of plasma samples obtained from 229 patients, as determined by ESI-TOFMS, and the degree of oxidized Cys34-HSA determined by HPLC. The Cys-Cys34-HSA fraction was significantly increased with the progression of liver cirrhosis, and was reduced by branched chain amino acids (BCAA) treatment. The changes in the Cys-Cys34-HSA fraction were significantly correlated with the alternations of the plasma levels of advanced oxidized protein products, an oxidative stress marker for proteins. The binding ability of endogenous substances (bilirubin and tryptophan) and drugs (warfarin and diazepam) to HSA purified from chronic liver disease patients were significantly suppressed but significantly improved by BCAA supplementation. Interestingly, the changes in this physiological function of HSA in chronic liver disease were correlated with the Cys-Cys34-HSA fraction. In conclusion, ESI-TOFMS is a suitable high throughput method for the rapid and sensitive quantification of Cys-Cys34-HSA in a large number of samples for evaluating oxidative stress related chronic disease progression or in response to a treatment. PMID:24416365

  16. Measurement of neosaxitoxin in human plasma using liquid-chromatography tandem mass spectrometry: Proof of concept for a pharmacokinetic application.

    PubMed

    Peake, Roy W A; Zhang, Victoria Y; Azcue, Nina; Hartigan, Christina E; Shkreta, Aida; Prabhakara, Jasmina; Berde, Charles B; Kellogg, Mark D

    2016-11-15

    Neosaxitoxin, a member of the saxitoxin family of paralytic shellfish poisoning toxins, has shown potential as an effective, long-acting, anesthetic. We describe the development and validation of a highly sensitive method for measurement of neosaxitoxin in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS) and provide evidence for its use in a human pharmacokinetic study. Samples were prepared using cation exchange solid phase extraction followed by hydrophilic interaction liquid chromatography and MS/MS detection in positive electrospray ionization mode. Multiple reaction monitoring was used to monitor neosaxitoxin (m/z 316.17>220.07) and the internal standard analogue decarbamoylneosaxitoxin (m/z 273.12>180.00). The method was validated for lower limit of quantification, precision, accuracy, linearity and matrix effect. The stability of neosaxitoxin in plasma matrix at various storage conditions was also investigated. Standard curves for calibration were linear (r>0.995) across the assay calibration range, 10 to 1000pg/mL. The analytical measurable range of the assay was 10-10,000pg/mL in plasma matrix. This method has demonstrated excellent sensitivity demonstrating a lower limit of quantification in human plasma of 10pg/mL. The mean, inter-batch variation was <5.2% across the concentration range 30 to 800pg/mL. This method was successfully used in a phase 1 trial to investigate the pharmacokinetic profile of neosaxitoxin in humans following the intravenous administration of the drug at a range of doses up to 40μg. We conclude that our high-sensitivity method for measurement of neosaxitoxin in human plasma is capable of supporting future clinical trials. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Human plasma metabolic profiles of benzydamine, a flavin-containing monooxygenase probe substrate, simulated with pharmacokinetic data from control and humanized-liver mice.

    PubMed

    Yamazaki-Nishioka, Miho; Shimizu, Makiko; Suemizu, Hiroshi; Nishiwaki, Megumi; Mitsui, Marina; Yamazaki, Hiroshi

    2018-02-01

    1. Benzydamine is used clinically as a nonsteroidal anti-inflammatory drug in oral rinses and is employed in preclinical research as a flavin-containing monooxygenase (FMO) probe substrate. In this study, plasma concentrations of benzydamine and its primary N-oxide and N-demethylated metabolites were investigated in control TK-NOG mice, in humanized-liver mice, and in mice whose liver cells had been ablated with ganciclovir. 2. Following oral administration of benzydamine (10 mg/kg) in humanized-liver TK-NOG mice, plasma concentrations of benzydamine N-oxide were slightly higher than those of demethyl benzydamine. In contrast, in control and ganciclovir-treated TK-NOG mice, concentrations of demethyl benzydamine were slightly higher than those of benzydamine N-oxide. 3. Simulations of human plasma concentrations of benzydamine and its N-oxide were achieved using simplified physiologically based pharmacokinetic models based on data from control TK-NOG mice and from reported benzydamine concentrations after low-dose administration in humans. Estimated clearance rates based on data from humanized-liver and ganciclovir-treated TK-NOG mice were two orders magnitude high. 4. The pharmacokinetic profiles of benzydamine were different for control and humanized-liver TK-NOG mice. Humanized-liver mice are generally accepted human models; however, drug oxidation in mouse kidney might need to be considered when probe substrates undergo FMO-dependent drug oxidation in mouse liver and kidney.

  18. Mass spectrometric characterization of human serum albumin dimer: A new potential biomarker in chronic liver diseases.

    PubMed

    Naldi, Marina; Baldassarre, Maurizio; Nati, Marina; Laggetta, Maristella; Giannone, Ferdinando Antonino; Domenicali, Marco; Bernardi, Mauro; Caraceni, Paolo; Bertucci, Carlo

    2015-08-10

    Human serum albumin (HSA) undergoes several structural alterations affecting its properties in pro-oxidant and pro-inflammatory environments, as it occurs during liver cirrhosis. These modifications include the formation of albumin dimers. Although HSA dimers were reported to be an oxidative stress biomarker, to date nothing is known about their role in liver cirrhosis and related complications. Additionally, no high sensitive analytical method was available for HSA dimers assessment in clinical settings. Thus the HSA dimeric form in human plasma was characterized by mass spectrometry using liquid chromatography tandem mass spectrometry (LC-ESI-Q-TOF) and matrix assisted laser desorption time of flight (MALDI-TOF) techniques. N-terminal and C-terminal truncated HSA, as well as the native HSA, undergo dimerization by binding another HSA molecule. This study demonstrated the presence of both homo- and hetero-dimeric forms of HSA. The dimerization site was proved to be at Cys-34, forming a disulphide bridge between two albumin molecules, as determined by LC-MS analysis after tryptic digestion. Interestingly, when plasma samples from cirrhotic subjects were analysed, the dimer/monomer ratio resulted significantly increased when compared to that of healthy subjects. These isoforms could represent promising biomarkers for liver disease. Additionally, this analytical approach leads to the relative quantification of the residual native HSA, with fully preserved structural integrity. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Human plasma enhances the expression of Staphylococcal microbial surface components recognizing adhesive matrix molecules promoting biofilm formation and increases antimicrobial tolerance In Vitro.

    PubMed

    Cardile, Anthony P; Sanchez, Carlos J; Samberg, Meghan E; Romano, Desiree R; Hardy, Sharanda K; Wenke, Joseph C; Murray, Clinton K; Akers, Kevin S

    2014-07-17

    Microbial biofilms have been associated with the development of chronic human infections and represent a clinical challenge given their increased antimicrobial tolerance. Staphylococcus aureus is a major human pathogen causing a diverse range of diseases, of which biofilms are often involved. Staphylococcal attachment and the formation of biofilms have been shown to be facilitated by host factors that accumulate on surfaces. To better understand how host factors enhance staphylococcal biofilm formation, we evaluated the effect of whole human plasma on biofilm formation in clinical isolates of S. aureus and the expression of seven microbial surface components recognizing adhesive matrix molecules (MSCRAMMs) known to be involved in biofilm formation by quantitative real-time PCR. We also evaluated whether plasma augmented changes in S. aureus biofilm morphology and antimicrobial resistance. Exposure of clinical isolates of S. aureus to human plasma (10%) within media, and to a lesser extent when coated onto plates, significantly enhanced biofilm formation in all of the clinical isolates tested. Compared to biofilms grown under non-supplemented conditions, plasma-augmented biofilms displayed significant changes in both the biofilm phenotype and cell morphology as determined by confocal scanning laser microscopy (CLSM) and scanning electron microscopy (SEM), respectively. Exposure of bacteria to plasma resulted in a significant fold-increase in MSCRAMM expression in both a time and isolate-dependent manner. Additionally, plasma-augmented biofilms displayed an increased tolerance to vancomycin compared to biofilms grown in non-supplemented media. Collectively, these studies support previous findings demonstrating a role for host factors in biofilm formation and provide further insight into how plasma, a preferred growth medium for staphylococcal biofilm formation enhances as well as augments other intrinsic properties of S. aureus biofilms. Consequently, these findings indicate that incorporation of host factors may be necessary to better replicate in vivo conditions and for the best utility of a clinical biofilm assay to evaluate the process of biofilm formation and treatments.

  20. Proteomic profiling of human plasma exosomes identifies PPAR{gamma} as an exosome-associated protein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looze, Christopher; Yui, David; Leung, Lester

    Exosomes are nanovesicles that are released from cells as a mechanism of cell-free intercellular communication. Only a limited number of proteins have been identified from the plasma exosome proteome. Here, we developed a multi-step fractionation scheme incorporating gel exclusion chromatography, rate zonal centrifugation through continuous sucrose gradients, and high-speed centrifugation to purify exosomes from human plasma. Exosome-associated proteins were separated by SDS-PAGE and 66 proteins were identified by LC-MS/MS, which included both cellular and extracellular proteins. Furthermore, we identified and characterized peroxisome proliferator-activated receptor-{gamma} (PPAR{gamma}), a nuclear receptor that regulates adipocyte differentiation and proliferation, as well as immune and inflammatorymore » cell functions, as a novel component of plasma-derived exosomes. Given the important role of exosomes as intercellular messengers, the discovery of PPAR{gamma} as a component of human plasma exosomes identifies a potential new pathway for the paracrine transfer of nuclear receptors.« less

Top