Sample records for hz sampling frequency

  1. Commercial video frame rates can produce reliable results for both normal and CP spastic gait's spatiotemporal, angular, and linear displacement variables.

    PubMed

    Nikodelis, Thomas; Moscha, Dimitra; Metaxiotis, Dimitris; Kollias, Iraklis

    2011-08-01

    To investigate what sampling frequency is adequate for gait, the correlation of spatiotemporal parameters and the kinematic differences, between normal and CP spastic gait, for three sampling frequencies (100 Hz, 50 Hz, 25 Hz) were assessed. Spatiotemporal, angular, and linear displacement variables in the sagittal plane along with their 1st and 2nd derivatives were analyzed. Spatiotemporal stride parameters were highly correlated among the three sampling frequencies. The statistical model (2 × 3 ANOVA) gave no interactions between the factors group and frequency, indicating that group differences were invariant of sampling frequency. Lower frequencies led to smoother curves for all the variables, with a loss of information though, especially for the 2nd derivatives, having a homologous effect as the one of oversmoothing. It is proposed that in the circumstance that only spatiotemporal stride parameters, as well as angular and linear displacements are to be used, in gait reports, then commercial video camera speeds (25/30 Hz, 50/60 Hz when deinterlaced) can be considered as a low-cost solution to produce acceptable results.

  2. [Development of the soft independent modelling of class analogies model to discrimination Vibrio parahemolyticus by Smartongue].

    PubMed

    Huang, Jianfeng; Zhao, Guangying; Dou, Wenchao

    2011-04-01

    To explore a new rapid detection method for detecting of Food pathogens. We used the Smartongue, to determine the composition informations of the liquid culture samples and combined with soft independent modelling of class analogies (SIMCA) to analyze their respective species, then set up a Smartongue -SIMCA model to discriminate the V. parahaemolyticus. The Smartongue has 6 working electrodes and three frequency segments, we can built 18 discrimination models in one detection. After comparing all the 18 discrimination models, the optimal working electrodes and frequency segments were selected out, they were: palladium electrode in 1 Hz frequency segment, tungsten electrode in 100 Hz and silver electrode in 100 Hz. Then 10 species of pathogenic Vibrio were discriminated by the 3 models. The V. damsela, V. metschnikovii, V. alginalyticus, V. cincinnatiensis, V. metschnikovii and V. cholerae O serogroup samples could be discriminated by the SIMCA model of V. parahaemolyticus with palladium electrode 1 Hz frequency segment; V. mimicus and V. vulnincus samples could be discriminated by the SIMCA model of V. parahaemolyticus with tungsten electrode 100 Hz frequency segment; V. carcariae and V. cholerae non-O serogroup samples could be discriminated with the SIMCA model of V. parahaemolyticus in silver electrode 100 Hz frequency segment. The accurate discrimination of ten species of Vibrio samples is 100%. The Smartongue combined with SIMCA can discriminate V. parahaemolyticus with other pathogenic Vibrio effectively. It has a promising future as a new rapid detection method for V. parahaemolyticus.

  3. Effect of Frequency and Waveform on Inactivation of Escherichia coli O157:H7 and Salmonella enterica Serovar Typhimurium in Salsa by Ohmic Heating

    PubMed Central

    Lee, Su-Yeon; Ryu, Sangryeol

    2013-01-01

    The effect of frequency of alternating current during ohmic heating on electrode corrosion, heating rate, inactivation of food-borne pathogens, and quality of salsa was investigated. The impact of waveform on heating rate was also investigated. Salsa was treated with various frequencies (60 Hz to 20 kHz) and waveforms (sine, square, and sawtooth) at a constant electric field strength of 12.5 V/cm. Electrode corrosion did not occur when the frequency exceeded 1 kHz. The heating rate of the sample was dependent on frequency up to 500 Hz, but there was no significant difference (P > 0.05) in the heating rate when the frequency was increased above 1 kHz. The electrical conductivity of the sample increased with a rise in the frequency. At a frequency of 60 Hz, the square wave produced a lower heating rate than that of sine and sawtooth waves. The heating rate between waveforms was not significantly (P > 0.05) different when the frequency was >500 Hz. As the frequency increased, the treatment time required to reduce Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium to below the detection limit (1 log CFU/g) decreased without affecting product quality. These results suggest that ohmic heating can be effectively used to pasteurize salsa and that the effect of inactivation is dependent on frequency and electrical conductivity rather than waveform. PMID:23023752

  4. Effect of frequency and waveform on inactivation of Escherichia coli O157:H7 and Salmonella enterica Serovar Typhimurium in salsa by ohmic heating.

    PubMed

    Lee, Su-Yeon; Ryu, Sangryeol; Kang, Dong-Hyun

    2013-01-01

    The effect of frequency of alternating current during ohmic heating on electrode corrosion, heating rate, inactivation of food-borne pathogens, and quality of salsa was investigated. The impact of waveform on heating rate was also investigated. Salsa was treated with various frequencies (60 Hz to 20 kHz) and waveforms (sine, square, and sawtooth) at a constant electric field strength of 12.5 V/cm. Electrode corrosion did not occur when the frequency exceeded 1 kHz. The heating rate of the sample was dependent on frequency up to 500 Hz, but there was no significant difference (P > 0.05) in the heating rate when the frequency was increased above 1 kHz. The electrical conductivity of the sample increased with a rise in the frequency. At a frequency of 60 Hz, the square wave produced a lower heating rate than that of sine and sawtooth waves. The heating rate between waveforms was not significantly (P > 0.05) different when the frequency was >500 Hz. As the frequency increased, the treatment time required to reduce Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium to below the detection limit (1 log CFU/g) decreased without affecting product quality. These results suggest that ohmic heating can be effectively used to pasteurize salsa and that the effect of inactivation is dependent on frequency and electrical conductivity rather than waveform.

  5. Measuring saccade peak velocity using a low-frequency sampling rate of 50 Hz.

    PubMed

    Wierts, Roel; Janssen, Maurice J A; Kingma, Herman

    2008-12-01

    During the last decades, small head-mounted video eye trackers have been developed in order to record eye movements. Real-time systems-with a low sampling frequency of 50/60 Hz-are used for clinical vestibular practice, but are generally considered not to be suited for measuring fast eye movements. In this paper, it is shown that saccadic eye movements, having an amplitude of at least 5 degrees, can, in good approximation, be considered to be bandwidth limited up to a frequency of 25-30 Hz. Using the Nyquist theorem to reconstruct saccadic eye movement signals at higher temporal resolutions, it is shown that accurate values for saccade peak velocities, recorded at 50 Hz, can be obtained, but saccade peak accelerations and decelerations cannot. In conclusion, video eye trackers sampling at 50/60 Hz are appropriate for detecting the clinical relevant saccade peak velocities in contrast to what has been stated up till now.

  6. Non-Wovens as Sound Reducers

    NASA Astrophysics Data System (ADS)

    Belakova, D.; Seile, A.; Kukle, S.; Plamus, T.

    2018-04-01

    Within the present study, the effect of hemp (40 wt%) and polyactide (60 wt%), non-woven surface density, thickness and number of fibre web layers on the sound absorption coefficient and the sound transmission loss in the frequency range from 50 to 5000 Hz is analysed. The sound insulation properties of the experimental samples have been determined, compared to the ones in practical use, and the possible use of material has been defined. Non-woven materials are ideally suited for use in acoustic insulation products because the arrangement of fibres produces a porous material structure, which leads to a greater interaction between sound waves and fibre structure. Of all the tested samples (A, B and D), the non-woven variant B exceeded the surface density of sample A by 1.22 times and 1.15 times that of sample D. By placing non-wovens one above the other in 2 layers, it is possible to increase the absorption coefficient of the material, which depending on the frequency corresponds to C, D, and E sound absorption classes. Sample A demonstrates the best sound absorption of all the three samples in the frequency range from 250 to 2000 Hz. In the test frequency range from 50 to 5000 Hz, the sound transmission loss varies from 0.76 (Sample D at 63 Hz) to 3.90 (Sample B at 5000 Hz).

  7. A study of Acoustics Performance on Natural Fibre Composite

    NASA Astrophysics Data System (ADS)

    Nizam Yahya, Musli; Sambu, Mathan; Latif, Hanif Abdul; Junaid, Thuwaibah Mohd

    2017-08-01

    Natural fibres are fibre that can be directly obtained from an animal, mineral, or vegetable sources. Recently natural materials are becoming good alternatives for synthetic material as they provide good health to greener environment. The purpose of this study is to investigate and compare the acoustic characteristics of natural fibres; Kenaf fibre, Ijuk fibre, coconut coir and palm Oil frond. During the processing stage, each fibre is reinforced with 60:40 weight ratio of natural rubber (NR) separately. The fibres are then compressed after the natural rubber (NR) treatment into circular samples, of 28 mm and 100 mm diameters respectively. The thickness of each sample is fixed at 50mm. The acoustical performances were evaluated by using an impedance tube instrument. The frequency peak value of Kenaf is obtained in a range of 700 Hz - 800 Hz, while for coconut coir is at 1000 Hz - 1075 Hz frequency range. Palm oil frond gives high frequency at 850 Hz - 1200 Hz. However, Only Ijuk has obtained the highest frequency range of 3200 Hz - 3400 Hz. The results demonstrate that these fibres are a promising light and environment-friendly sound absorption material as they are ready to replace the common synthetic fibre.

  8. Estimating fish swimming metrics and metabolic rates with accelerometers: the influence of sampling frequency.

    PubMed

    Brownscombe, J W; Lennox, R J; Danylchuk, A J; Cooke, S J

    2018-06-21

    Accelerometry is growing in popularity for remotely measuring fish swimming metrics, but appropriate sampling frequencies for accurately measuring these metrics are not well studied. This research examined the influence of sampling frequency (1-25 Hz) with tri-axial accelerometer biologgers on estimates of overall dynamic body acceleration (ODBA), tail-beat frequency, swimming speed and metabolic rate of bonefish Albula vulpes in a swim-tunnel respirometer and free-swimming in a wetland mesocosm. In the swim tunnel, sampling frequencies of ≥ 5 Hz were sufficient to establish strong relationships between ODBA, swimming speed and metabolic rate. However, in free-swimming bonefish, estimates of metabolic rate were more variable below 10 Hz. Sampling frequencies should be at least twice the maximum tail-beat frequency to estimate this metric effectively, which is generally higher than those required to estimate ODBA, swimming speed and metabolic rate. While optimal sampling frequency probably varies among species due to tail-beat frequency and swimming style, this study provides a reference point with a medium body-sized sub-carangiform teleost fish, enabling researchers to measure these metrics effectively and maximize study duration. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Activity classification using the GENEA: optimum sampling frequency and number of axes.

    PubMed

    Zhang, Shaoyan; Murray, Peter; Zillmer, Ruediger; Eston, Roger G; Catt, Michael; Rowlands, Alex V

    2012-11-01

    The GENEA shows high accuracy for classification of sedentary, household, walking, and running activities when sampling at 80 Hz on three axes. It is not known whether it is possible to decrease this sampling frequency and/or the number of axes without detriment to classification accuracy. The purpose of this study was to compare the classification rate of activities on the basis of data from a single axis, two axes, and three axes, with sampling rates ranging from 5 to 80 Hz. Sixty participants (age, 49.4 yr (6.5 yr); BMI, 24.6 kg·m (3.4 kg·m)) completed 10-12 semistructured activities in the laboratory and outdoor environment while wearing a GENEA accelerometer on the right wrist. We analyzed data from single axis, dual axes, and three axes at sampling rates of 5, 10, 20, 40, and 80 Hz. Mathematical models based on features extracted from mean, SD, fast Fourier transform, and wavelet decomposition were built, which combined one of the numbers of axes with one of the sampling rates to classify activities into sedentary, household, walking, and running. Classification accuracy was high irrespective of the number of axes for data collected at 80 Hz (96.93% ± 0.97%), 40 Hz (97.4% ± 0.73%), 20 Hz (96.86% ± 1.12%), and 10 Hz (97.01% ± 1.01%) but dropped for data collected at 5 Hz (94.98% ± 1.36%). Sampling frequencies >10 Hz and/or more than one axis of measurement were not associated with greater classification accuracy. Lower sampling rates and measurement of a single axis would result in a lower data load, longer battery life, and higher efficiency of data processing. Further research should investigate whether a lower sampling rate and a single axis affects classification accuracy when considering a wider range of activities.

  10. Application of chemometrics to assess the influence of ultrasound frequency, Lactobacillus sakei culture and drying on beef jerky manufacture: Impact on amino acid profile, organic acids, texture and colour.

    PubMed

    Shikha Ojha, K; Granato, Daniel; Rajuria, Gaurav; Barba, Francisco J; Kerry, Joseph P; Tiwari, Brijesh K

    2018-01-15

    The effects of ultrasound (US) frequency, addition of Lactobacillus sakei culture and drying time on key nutritional (protein, amino acids, and organic acids) and physicochemical properties (texture and colour) of cultured and uncultured beef jerky were evaluated. Cultured and uncultured jerky samples were subjected to US frequencies of 25kHz, 33kHz and 45kHz for 30min prior to marination and drying. Principal component analysis demonstrated a significant effect of beef jerky processing conditions on physicochemical properties. Taurine content of jerky samples was found to increase with an increase in ultrasonic frequencies for cultured samples. No significant changes in colour values were observed for ultrasound pre-treated and control samples. Interactive effects of culture treatment, drying and ultrasonic frequency were observed. This study demonstrates that the nutritional profile of beef jerky can be improved through the incorporation of L. sakei. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Multi-frequency localization of aberrant brain activity in autism spectrum disorder.

    PubMed

    Xiang, Jing; Korostenskaja, Milena; Molloy, Cynthia; deGrauw, Xinyao; Leiken, Kimberly; Gilman, Carley; Meinzen-Derr, Jareen; Fujiwara, Hisako; Rose, Douglas F; Mitchell, Terry; Murray, Donna S

    2016-01-01

    The abnormality of intrinsic brain activity in autism spectrum disorders (ASDs) is still inconclusive. Contradictory results have been found pointing towards hyper-activity or hypo-activity in various brain regions. The present research aims to investigate the spatial and spectral signatures of aberrant brain activity in an unprecedented frequency range of 1-2884 Hz at source levels in ASD using newly developed methods. Seven ASD subjects and age- and gender-matched controls were studied using a high-sampling rate magnetoencephalography (MEG) system. Brain activity in delta (1-4 Hz), theta (4-8 Hz), alpha (8-12 Hz), beta (12-30 Hz), low gamma (30-55 Hz), high gamma (65-90 Hz), ripples (90-200 Hz), high-frequency oscillations (HFOs, 200-1000 Hz), and very high-frequency oscillations (VHFOs, 1000-2884 Hz) was volumetrically localized and measured using wavelet and beamforming. In comparison to controls, ASD subjects had significantly higher odds of alpha activity (8-12 Hz) in the sensorimotor cortex (mu rhythm), and generally high-frequency activity (90-2884 Hz) in the frontal cortex. The source power of HFOs (200-1000 Hz) in the frontal cortex in ASD was significantly elevated as compared with controls. The results suggest that ASD has significantly altered intrinsic brain activity in both low- and high-frequency ranges. Increased intrinsic high-frequency activity in the frontal cortex may play a key role in ASD. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  12. Low frequency noise elimination technique for 24-bit Σ-Δ data acquisition systems.

    PubMed

    Qu, Shao-Bo; Robert, Olivier; Lognonné, Philippe; Zhou, Ze-Bing; Yang, Shan-Qing

    2015-03-01

    Low frequency 1/f noise is one of the key limiting factors of high precision measurement instruments. In this paper, digital correlated double sampling is implemented to reduce the offset and low frequency 1/f noise of a data acquisition system with 24-bit sigma delta (Σ-Δ) analog to digital converter (ADC). The input voltage is modulated by cross-coupled switches, which are synchronized to the sampling clock, and converted into digital signal by ADC. By using a proper switch frequency, the unwanted parasitic signal frequencies generated by the switches are avoided. The noise elimination processing is made through the principle of digital correlated double sampling, which is equivalent to a time shifted subtraction for the sampled voltage. The low frequency 1/f noise spectrum density of the data acquisition system is reduced to be flat down to the measurement frequency lower limit, which is about 0.0001 Hz in this paper. The noise spectrum density is eliminated by more than 60 dB at 0.0001 Hz, with a residual noise floor of (9 ± 2) nV/Hz(1/2) which is limited by the intrinsic white noise floor of the ADC above its corner frequency.

  13. Alternating frequencies of transcutaneous electric nerve stimulation: does it produce greater analgesic effects on mechanical and thermal pain thresholds?

    PubMed

    Tong, K C; Lo, Sing Kai; Cheing, Gladys L

    2007-10-01

    To determine whether alternating frequency transcutaneous electric nerve stimulation (TENS) at 2 and 100Hz (2/100Hz) has a more potent hypoalgesic effect than a fixed frequency at 2 or 100Hz in healthy participants. A single-blind randomized controlled trial with a convenience sample. University physiotherapy department. Sixty-four healthy volunteers (32 men [mean age, 28.1+/-5.9y], 32 women [mean age, 27.7+/-5.6y]) were recruited and randomly divided into 4 groups. The 4 groups received TENS delivered at (1) 2Hz; (2) 100Hz; (3) 2/100Hz alternating frequency; and (4) no treatment (control group), respectively. Electric stimulation was applied over the anterior aspect of the dominant forearm for 30 minutes. Mechanical pain thresholds (MPTs) and heat pain thresholds (HPTs) were recorded before, during, and after TENS stimulation. The data were analyzed using linear mixed models, with group treated as a between-subject factor and time a within-subject factor. During and shortly after electric stimulation, HPT increased significantly in the alternating frequency stimulation group (P=.024). MPT increased significantly in both the 100Hz (P=.008) and the alternating frequency groups (P=.012), but the increase was substantially larger in the 100Hz group. Alternating frequency stimulation produced a greater elevation in the HPT, but a greater increase in the MPT was achieved using 100Hz stimulation.

  14. The Development of Phasemeter for Taiji Space Gravitational Wave Detection

    NASA Astrophysics Data System (ADS)

    Liu, Heshan; Luo, Ziren; Jin, Gang

    2018-05-01

    Taiji space gravitational wave detection utilizes the laser interferometer to convert the tiny distance change into the phase fluctuation of the beat note. As to realize the sensitivity of 1 pm/√ Hz, the phasemeter needs to calculate the phase with the precision of 2π μ rad/√ Hz in the frequency range of 0.1 mHz and 1 Hz. In this paper, we report recent progress of the phasemeter for Taiji. Noises which possibly affect the measurement sensitivity are tested and discussed, especially the sampling noise and the frequency jitter. Finally, the accuracy of the phasemeter is calibrated. The result shows that the sensitivity has reached the requirement of Taiji in the frequencies between 0.01 Hz and 1 Hz, 0.1 mHz-1 mHz. Noises in the range of 1 mHz and 0.01 Hz, which have not yet depressed well, are dominated by the clocking jitter and the thermal fluctuation.

  15. Temporal-frequency tuning of cross-orientation suppression in the cat striate cortex.

    PubMed

    Allison, J D; Smith, K R; Bonds, A B

    2001-01-01

    A sinusoidal mask grating oriented orthogonally to and superimposed onto an optimally oriented base grating reduces a cortical neuron's response amplitude. The spatial selectivity of cross-orientation suppression (XOR) has been described, so for this paper we investigated the temporal properties of XOR. We recorded from single striate cortical neurons (n = 72) in anesthetized and paralyzed cats. After quantifying the spatial and temporal characteristics of each cell's excitatory response to a base grating, we measured the temporal-frequency tuning of XOR by systematically varying the temporal frequency of a mask grating placed at a null orientation outside of the cell's excitatory orientation domain. The average preferred temporal frequency of the excitatory response of the neurons in our sample was 3.8 (+/- 1.5 S.D.) Hz. The average cutoff frequency for the sample was 16.3 (+/- 1.7) Hz. The average preferred temporal frequency (7.0 +/- 2.6 Hz) and cutoff frequency (20.4 +/- 6.9 Hz) of the XOR were significantly higher. The differences averaged 1.1 (+/- 0.6) octaves for the peaks and 0.3 (+/- 0.4) octaves for the cutoffs. The XOR mechanism's preference for high temporal frequencies suggests a possible extrastriate origin for the effect and could help explain the low-pass temporal-frequency response profile displayed by most striate cortical neurons.

  16. Viscoelastic properties of three vocal-fold injectable biomaterials at low audio frequencies.

    PubMed

    Klemuk, Sarah A; Titze, Ingo R

    2004-09-01

    Previous measurements of viscoelastic properties of Zyderm were to be extended to low audio frequencies, and properties of two other biomaterials not previously measured, thiolated hyaluronic acid (HA-DTPH) and Cymetra, were obtained. Rheologic investigation. Oscillatory shear stress was applied to each sample using a controlled stress rheometer at frequencies between 0.01 and 100 Hz with a parallel plate apparatus. Versuscoelastic moduli were recorded at each frequency. The calculated resonance frequency of the machine and sample were then used to determine the maximum frequency at which reliable data existed. Extrapolation functions were fit to viscoelastic parameters, which predicted the properties up to 1,000 Hz. Frequency trends of Zyderm were similar to those previously reported, whereas magnitudes were different. The elastic moduli logarithmically increased with frequency, whereas dynamic viscosity demonstrated shear thinning, a condition of primary importance for humans to vocalize over a broad frequency range. Previous measurements were extended from 15 Hz up to 74 Hz. Differences in magnitude between a previous study and the present study were attributed to particulate orientation during testing. Cymetra was found to have nearly identical viscoelastic properties to those of bovine collagen, both in magnitude and frequency trend, with reliable measures extending up to 81 Hz. Rheologic properties of the hyaluronic acid gel were the closest match to cadaveric vocal fold mucosa in magnitude and frequency trend. Viscoelastic properties of Cymetra and Zyderm are nearly the same and are significantly greater than those of vocal fold mucosa. HA-DTPH possesses a good viscoelastic match to vocal fold mucosa and may be useful in future lamina propria repair.

  17. Dispersion of Dielectric Permittivity in a Nanocrystalline Cellulose-Triglycine Sulfate Composite at Low and Ultralow Frequencies

    NASA Astrophysics Data System (ADS)

    Thu'o'ng, Nguyen Hoai; Sidorkin, A. S.; Milovidova, S. D.

    2018-03-01

    The dispersion of dielectric permittivity in nanocrystalline cellulose-triglycine sulfate composites is studied in the range of frequencies from 10-3 to 106 Hz, at temperatures varying from room temperature to the temperature of phase transition in this composite (54°C), in weak electric fields (1 V cm-1). Two behaviors for the dielectric dispersion are identified in the studied frequency range: at ultralow frequencies (10-3-10 Hz), the dispersion is due to Maxwell-Wagner polarization, while at higher frequencies (10-106 Hz), the dispersion is due to the movement of domain walls in the embedded triglycine sulfate crystallites. An additional peak in the temperature-dependent profiles of dielectric permittivity is detected at lower temperatures in freshly prepared samples of the considered composite; we associate it with the presence of residual water in these samples.

  18. Discriminating features of echolocation clicks of melon-headed whales (Peponocephala electra), bottlenose dolphins (Tursiops truncatus), and Gray's spinner dolphins (Stenella longirostris longirostris).

    PubMed

    Baumann-Pickering, Simone; Wiggins, Sean M; Hildebrand, John A; Roch, Marie A; Schnitzler, Hans-Ulrich

    2010-10-01

    Spectral parameters were used to discriminate between echolocation clicks produced by three dolphin species at Palmyra Atoll: melon-headed whales (Peponocephala electra), bottlenose dolphins (Tursiops truncatus) and Gray's spinner dolphins (Stenella longirostris longirostris). Single species acoustic behavior during daytime observations was recorded with a towed hydrophone array sampling at 192 and 480 kHz. Additionally, an autonomous, bottom moored High-frequency Acoustic Recording Package (HARP) collected acoustic data with a sampling rate of 200 kHz. Melon-headed whale echolocation clicks had the lowest peak and center frequencies, spinner dolphins had the highest frequencies and bottlenose dolphins were nested in between these two species. Frequency differences were significant. Temporal parameters were not well suited for classification. Feature differences were enhanced by reducing variability within a set of single clicks by calculating mean spectra for groups of clicks. Median peak frequencies of averaged clicks (group size 50) of melon-headed whales ranged between 24.4 and 29.7 kHz, of bottlenose dolphins between 26.7 and 36.7 kHz, and of spinner dolphins between 33.8 and 36.0 kHz. Discriminant function analysis showed the ability to correctly discriminate between 93% of melon-headed whales, 75% of spinner dolphins and 54% of bottlenose dolphins.

  19. Study on sound-speed dispersion in a sandy sediment at frequency ranges of 0.5-3 kHz and 90-170 kHz

    NASA Astrophysics Data System (ADS)

    Yu, Sheng-qi; Liu, Bao-hua; Yu, Kai-ben; Kan, Guang-ming; Yang, Zhi-guo

    2017-03-01

    In order to study the properties of sound-speed dispersion in a sandy sediment, the sound speed was measured both at high frequency (90-170 kHz) and low frequency (0.5-3 kHz) in laboratory environments. At high frequency, a sampling measurement was conducted with boiled and uncooked sand samples collected from the bottom of a large water tank. The sound speed was directly obtained through transmission measurement using single source and single hydrophone. At low frequency, an in situ measurement was conducted in the water tank, where the sandy sediment had been homogeneously paved at the bottom for a long time. The sound speed was indirectly inverted according to the traveling time of signals received by three buried hydrophones in the sandy sediment and the geometry in experiment. The results show that the mean sound speed is approximate 1710-1713 m/s with a weak positive gradient in the sand sample after being boiled (as a method to eliminate bubbles as much as possible) at high frequency, which agrees well with the predictions of Biot theory, the effective density fluid model (EDFM) and Buckingham's theory. However, the sound speed in the uncooked sandy sediment obviously decreases (about 80%) both at high frequency and low frequency due to plenty of bubbles in existence. And the sound-speed dispersion performs a weak negative gradient at high frequency. Finally, a water-unsaturated Biot model is presented for trying to explain the decrease of sound speed in the sandy sediment with plenty of bubbles.

  20. Note: Inter-satellite laser range-rate measurement by using digital phase locked loop.

    PubMed

    Liang, Yu-Rong; Duan, Hui-Zong; Xiao, Xin-Long; Wei, Bing-Bing; Yeh, Hsien-Chi

    2015-01-01

    This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future's gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10(-8) Hz/Hz(1/2)@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.

  1. Note: Inter-satellite laser range-rate measurement by using digital phase locked loop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Yu-Rong; Department of Electronics and Information Engineering, Huazhong University of Science and Technology, 1037 Luo Yu Road, Wuhan 430074; Duan, Hui-Zong

    2015-01-15

    This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future’s gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10{sup −8} Hz/Hz{sup 1/2}@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.

  2. Note: Inter-satellite laser range-rate measurement by using digital phase locked loop

    NASA Astrophysics Data System (ADS)

    Liang, Yu-Rong; Duan, Hui-Zong; Xiao, Xin-Long; Wei, Bing-Bing; Yeh, Hsien-Chi

    2015-01-01

    This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future's gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10-8 Hz/Hz1/2@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.

  3. Effect of Uniaxial Tensile Cyclic Loading Regimes on Matrix Organization and Tenogenic Differentiation of Adipose-Derived Stem Cells Encapsulated within 3D Collagen Scaffolds

    PubMed Central

    Stasuk, Alexander

    2017-01-01

    Adipose-derived mesenchymal stem cells have become a popular cell choice for tendon repair strategies due to their relative abundance, ease of isolation, and ability to differentiate into tenocytes. In this study, we investigated the solo effect of different uniaxial tensile strains and loading frequencies on the matrix directionality and tenogenic differentiation of adipose-derived stem cells encapsulated within three-dimensional collagen scaffolds. Samples loaded at 0%, 2%, 4%, and 6% strains and 0.1 Hz and 1 Hz frequencies for 2 hours/day over a 7-day period using a custom-built uniaxial tensile strain bioreactor were characterized in terms of matrix organization, cell viability, and musculoskeletal gene expression profiles. The results displayed that the collagen fibers of the loaded samples exhibited increased matrix directionality with an increase in strain values. Gene expression analyses demonstrated that ASC-encapsulated collagen scaffolds loaded at 2% strain and 0.1 Hz frequency showed significant increases in extracellular matrix genes and tenogenic differentiation markers. Importantly, no cross-differentiation potential to osteogenic, chondrogenic, and myogenic lineages was observed at 2% strain and 0.1 Hz frequency loading condition. Thus, 2% strain and 0.1 Hz frequency were identified as the appropriate mechanical loading regime to induce tenogenic differentiation of adipose-derived stem cells cultured in a three-dimensional environment. PMID:29375625

  4. Microwave differential dilatometer measures 10 - 12 m, at 1 Hz

    NASA Astrophysics Data System (ADS)

    Aschero, G.; Mango, F.; Gizdulich, P.

    1996-12-01

    To check and measure the converse piezoelectric effect in bone samples, we had to detect displacements in the range of 1-100 pm with three kinds of restrictions: (1) the biological nature of the samples imposes severe limits in selecting a suitable device and method; (2) such a method has to take into account some clinical applications to which the experiment is devoted; (3) the piezoelectric behavior of bone samples is particularly interesting at low frequencies, around 1 Hz. For such reasons we modified an existing dilatometer based on a microwave differential spectrometer. A 14 GHz klystron, linearly modulated in frequency by a triangular 50 Hz voltage applied to the repeller, is connected, via magic T, to two identical cavities tunable around 14 GHz and whose resonance curves are recorded by crystal detectors. When one of the two cavities changes its height according to the length variations of the sample, its resonance frequency varies resulting in a shift of the resonant curve with respect to the resonance curve of the other cavity acting as reference. The comparison between the cavities' responses is performed by a pulse technique transforming the frequency shifts into time intervals, that are then converted into dc voltages. The differential character of this measurement avoids the need for the microwave source stabilization. The relative shift in frequency is measured with an accuracy better than 500 Hz. This accuracy allows us to measure displacements smaller than 7 nm in the cavity's height. After 2 h of warmup, thanks to the differential arrangement of the system, thermal or other drifts are not detectable within a lapse of time of 12 h. This feature allows coherent signal averaging over long periods. With a piezoelectric ceramic stack moving 100 pm in square wave fashion at 50 mHz we found that the signal to noise ratio was 20 dB after 1000 cycles of signal averaging, when our bandpass filter was tuned at 1 Hz. In conclusion, this system can detect periodic displacements as small as 1 pm in a short time and reliably. Due to the operational simplicity and stability, at room temperature and humidity, the device is suitable for dilatometric measurements on biological samples.

  5. Nanohertz frequency determination for the gravity probe B high frequency superconducting quantum interference device signal.

    PubMed

    Salomon, M; Conklin, J W; Kozaczuk, J; Berberian, J E; Keiser, G M; Silbergleit, A S; Worden, P; Santiago, D I

    2011-12-01

    In this paper, we present a method to measure the frequency and the frequency change rate of a digital signal. This method consists of three consecutive algorithms: frequency interpolation, phase differencing, and a third algorithm specifically designed and tested by the authors. The succession of these three algorithms allowed a 5 parts in 10(10) resolution in frequency determination. The algorithm developed by the authors can be applied to a sampled scalar signal such that a model linking the harmonics of its main frequency to the underlying physical phenomenon is available. This method was developed in the framework of the gravity probe B (GP-B) mission. It was applied to the high frequency (HF) component of GP-B's superconducting quantum interference device signal, whose main frequency f(z) is close to the spin frequency of the gyroscopes used in the experiment. A 30 nHz resolution in signal frequency and a 0.1 pHz/s resolution in its decay rate were achieved out of a succession of 1.86 s-long stretches of signal sampled at 2200 Hz. This paper describes the underlying theory of the frequency measurement method as well as its application to GP-B's HF science signal.

  6. Wideband Aural Acoustic Absorbance Predicts Conductive Hearing Loss in Children

    PubMed Central

    Keefe, Douglas H.; Sanford, Chris A.; Ellison, John C.; Fitzpatrick, Denis F.; Gorga, Michael P.

    2013-01-01

    Objective This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. Design Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25 and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. Study Sample Absorbance and conventional 226-Hz tympanograms were measured in children of age 3 to 8 years with CHL and with normal hearing. Results Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 226-Hz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. Conclusions Absorbance accurately predicted CHL in children and was more accurate than conventional 226-Hz tympanometry. PMID:23072655

  7. Sub-nano tesla magnetic imaging based on room-temperature magnetic flux sensors with vibrating sample magnetometry

    NASA Astrophysics Data System (ADS)

    Adachi, Yoshiaki; Oyama, Daisuke

    2017-05-01

    We developed a two-dimensional imaging method for weak magnetic charge distribution using a commercially available magnetic impedance sensor whose magnetic field resolution is 10 pT/Hz1/2 at 10 Hz. When we applied the vibrating sample magnetometry, giving a minute mechanical vibration to the sample and detecting magnetic signals modulated by the vibration frequency, the effects of 1/f noise and the environmental low-frequency band noise were suppressed, and a weak magnetic charge distribution was obtained without magnetic shielding. Furthermore, improvement in the spatial resolution was also expected when the signals were demodulated at the second harmonic frequency of the vibration. In this paper, a preliminary magnetic charge imaging using the vibrating sample magnetometry and its results are demonstrated.

  8. Evaluation of sampling frequency, window size and sensor position for classification of sheep behaviour.

    PubMed

    Walton, Emily; Casey, Christy; Mitsch, Jurgen; Vázquez-Diosdado, Jorge A; Yan, Juan; Dottorini, Tania; Ellis, Keith A; Winterlich, Anthony; Kaler, Jasmeet

    2018-02-01

    Automated behavioural classification and identification through sensors has the potential to improve health and welfare of the animals. Position of a sensor, sampling frequency and window size of segmented signal data has a major impact on classification accuracy in activity recognition and energy needs for the sensor, yet, there are no studies in precision livestock farming that have evaluated the effect of all these factors simultaneously. The aim of this study was to evaluate the effects of position (ear and collar), sampling frequency (8, 16 and 32 Hz) of a triaxial accelerometer and gyroscope sensor and window size (3, 5 and 7 s) on the classification of important behaviours in sheep such as lying, standing and walking. Behaviours were classified using a random forest approach with 44 feature characteristics. The best performance for walking, standing and lying classification in sheep (accuracy 95%, F -score 91%-97%) was obtained using combination of 32 Hz, 7 s and 32 Hz, 5 s for both ear and collar sensors, although, results obtained with 16 Hz and 7 s window were comparable with accuracy of 91%-93% and F -score 88%-95%. Energy efficiency was best at a 7 s window. This suggests that sampling at 16 Hz with 7 s window will offer benefits in a real-time behavioural monitoring system for sheep due to reduced energy needs.

  9. Evaluation of sampling frequency, window size and sensor position for classification of sheep behaviour

    PubMed Central

    Walton, Emily; Casey, Christy; Mitsch, Jurgen; Vázquez-Diosdado, Jorge A.; Yan, Juan; Dottorini, Tania; Ellis, Keith A.; Winterlich, Anthony

    2018-01-01

    Automated behavioural classification and identification through sensors has the potential to improve health and welfare of the animals. Position of a sensor, sampling frequency and window size of segmented signal data has a major impact on classification accuracy in activity recognition and energy needs for the sensor, yet, there are no studies in precision livestock farming that have evaluated the effect of all these factors simultaneously. The aim of this study was to evaluate the effects of position (ear and collar), sampling frequency (8, 16 and 32 Hz) of a triaxial accelerometer and gyroscope sensor and window size (3, 5 and 7 s) on the classification of important behaviours in sheep such as lying, standing and walking. Behaviours were classified using a random forest approach with 44 feature characteristics. The best performance for walking, standing and lying classification in sheep (accuracy 95%, F-score 91%–97%) was obtained using combination of 32 Hz, 7 s and 32 Hz, 5 s for both ear and collar sensors, although, results obtained with 16 Hz and 7 s window were comparable with accuracy of 91%–93% and F-score 88%–95%. Energy efficiency was best at a 7 s window. This suggests that sampling at 16 Hz with 7 s window will offer benefits in a real-time behavioural monitoring system for sheep due to reduced energy needs. PMID:29515862

  10. The Effect of Nano Loading and Ultrasonic Compounding of EVA/LDPE/Nano-magnesium Hydroxide on Mechanical Properties and Distribution of Nano Particles

    NASA Astrophysics Data System (ADS)

    Azman, I. A.; Salleh, R. M.; Alauddin, S. M.; Shueb, M. I.

    2018-05-01

    Blends of Ethylene Vinyl Acetate (EVA) and Low-Density Polyethylene (LDPE) are promising composite which have good mechanical properties to environmental stress cracking. However, they lack fire resistant properties, which limits it usage in wire and cable industry. In order to improve flame retardancy ability, a range of nano-magnesium hydroxide (nano-MH) loading which is from 0 phr to maximum of 20 phr with ultrasonic extrusion 0-100 kHz frequencies have been introduced. Ultrasonic extrusion was used to improve the distribution of nano-MH. It was found that, 10 phr of nano loading with 100 kHz ultrasonic assisted has greater tensile strength compared to the nanocomposite without ultrasonication. Further increase of nano MH loading, will decrease the tensile properties. Better elongation at break was observed at10 phr nano-MH with the frequency of 50 kHz. The sample of 20 phr of nanoMH assisted with 50 kHz ultrasonic exhibits good flexural properties while 10 phr of nano-MH without the ultrasonic assisted demonstrates good in izod impact properties. From the evaluation of mechanical properties studied, it was found that 10 phr of nano-MH has shown the best performance among all the samples tested for EVA/LDPE/nano-MH composites. Transmission Electron Microscopy (TEM) has been conducted on 10 phr sample with different frequencies in order to observe the distribution of nano-MH particles. The sample with 100 kHz frequency shows more uniform dispersion of nano-MH in EVA/LDPE composites. This investigation indicates that the ultrasonic technology can enhance the mechanical properties studied as well as the dispersion of nano particles in the composite.

  11. Frequency modulation of neural oscillations according to visual task demands.

    PubMed

    Wutz, Andreas; Melcher, David; Samaha, Jason

    2018-02-06

    Temporal integration in visual perception is thought to occur within cycles of occipital alpha-band (8-12 Hz) oscillations. Successive stimuli may be integrated when they fall within the same alpha cycle and segregated for different alpha cycles. Consequently, the speed of alpha oscillations correlates with the temporal resolution of perception, such that lower alpha frequencies provide longer time windows for perceptual integration and higher alpha frequencies correspond to faster sampling and segregation. Can the brain's rhythmic activity be dynamically controlled to adjust its processing speed according to different visual task demands? We recorded magnetoencephalography (MEG) while participants switched between task instructions for temporal integration and segregation, holding stimuli and task difficulty constant. We found that the peak frequency of alpha oscillations decreased when visual task demands required temporal integration compared with segregation. Alpha frequency was strategically modulated immediately before and during stimulus processing, suggesting a preparatory top-down source of modulation. Its neural generators were located in occipital and inferotemporal cortex. The frequency modulation was specific to alpha oscillations and did not occur in the delta (1-3 Hz), theta (3-7 Hz), beta (15-30 Hz), or gamma (30-50 Hz) frequency range. These results show that alpha frequency is under top-down control to increase or decrease the temporal resolution of visual perception.

  12. [Multi-channel in vivo recording techniques: signal processing of action potentials and local field potentials].

    PubMed

    Xu, Jia-Min; Wang, Ce-Qun; Lin, Long-Nian

    2014-06-25

    Multi-channel in vivo recording techniques are used to record ensemble neuronal activity and local field potentials (LFP) simultaneously. One of the key points for the technique is how to process these two sets of recorded neural signals properly so that data accuracy can be assured. We intend to introduce data processing approaches for action potentials and LFP based on the original data collected through multi-channel recording system. Action potential signals are high-frequency signals, hence high sampling rate of 40 kHz is normally chosen for recording. Based on waveforms of extracellularly recorded action potentials, tetrode technology combining principal component analysis can be used to discriminate neuronal spiking signals from differently spatially distributed neurons, in order to obtain accurate single neuron spiking activity. LFPs are low-frequency signals (lower than 300 Hz), hence the sampling rate of 1 kHz is used for LFPs. Digital filtering is required for LFP analysis to isolate different frequency oscillations including theta oscillation (4-12 Hz), which is dominant in active exploration and rapid-eye-movement (REM) sleep, gamma oscillation (30-80 Hz), which is accompanied by theta oscillation during cognitive processing, and high frequency ripple oscillation (100-250 Hz) in awake immobility and slow wave sleep (SWS) state in rodent hippocampus. For the obtained signals, common data post-processing methods include inter-spike interval analysis, spike auto-correlation analysis, spike cross-correlation analysis, power spectral density analysis, and spectrogram analysis.

  13. Effect of Solar Radiation on Viscoelastic Properties of Bovine Leather: Temperature and Frequency Scans

    NASA Astrophysics Data System (ADS)

    Nalyanya, Kallen Mulilo; Rop, Ronald K.; Onyuka, Arthur S.

    2017-04-01

    This work presents both analytical and experimental results of the effect of unfiltered natural solar radiation on the thermal and dynamic mechanical properties of Boran bovine leather at both pickling and tanning stages of preparation. Samples cut from both pickled and tanned pieces of leather of appropriate dimensions were exposed to unfiltered natural solar radiation for time intervals ranging from 0 h (non-irradiated) to 24 h. The temperature of the dynamic mechanical analyzer was equilibrated at 30°C and increased to 240°C at a heating rate of 5°C \\cdot Min^{-1}, while its oscillation frequency varied from 0.1 Hz to 100 Hz. With the help of thermal analysis (TA) control software which analyzes and generates parameter means/averages at temperature/frequency range, the graphs were created by Microsoft Excel 2013 from the means. The viscoelastic properties showed linear frequency dependence within 0.1 Hz to 30 Hz followed by negligible frequency dependence above 30 Hz. Storage modulus (E') and shear stress (σ ) increased with frequency, while loss modulus (E''), complex viscosity (η ^{*}) and dynamic shear viscosity (η) decreased linearly with frequency. The effect of solar radiation was evident as the properties increased initially from 0 h to 6 h of irradiation followed by a steady decline to a minimum at 18 h before a drastic increase to a maximum at 24 h. Hence, tanning industry can consider the time duration of 24 h for sun-drying of leather to enhance the mechanical properties and hence the quality of the leather. At frequencies higher than 30 Hz, the dynamic mechanical properties are independent of the frequency. The frequency of 30 Hz was observed to be a critical value in the behavior in the mechanical properties of bovine hide.

  14. Fully developed turbulence and complex time singularities

    NASA Astrophysics Data System (ADS)

    Dombre, T.; Gagne, Y.; Hopfinger, E.

    The hypothesis of Frisch and Morf (1981), relating intermittent bursts observed in high-pass-filtered turbulent-flow data to complex time singularities in the solution of the Navier-Stokes equations, is tested experimentally. Velocity signals filtered at high-pass frequency 1 kHz and low-pass frequency 6 kHz are recorded for 7 min at sampling frequency 20 kHz in a flow of mean velocity 6.1 m/s, with mesh length d = 7.5 cm, observation point x/d = 40, R sub lambda = 67, dissipation length eta = 0.5 mm, and Kolmogorov frequency fK = about 2 kHz. The results are presented in graphs, and it is shown that the exponential behavior of the energy spectrum settles well before fK, the spectra of individual bursts having exponential behavior and delta(asterisk) values consistent with the Frisch-Morf hypothesis, at least for high-amplitude events.

  15. The high frequency characteristics of laser reflection and visible light during solid state disk laser welding

    NASA Astrophysics Data System (ADS)

    Gao, Xiangdong; You, Deyong; Katayama, Seiji

    2015-07-01

    Optical properties are related to weld quality during laser welding. Visible light radiation generated from optical-induced plasma and laser reflection is considered a key element reflecting weld quality. An in-depth analysis of the high-frequency component of optical signals is conducted. A combination of a photoelectric sensor and an optical filter helped to obtain visible light reflection and laser reflection in the welding process. Two groups of optical signals were sampled at a high sampling rate (250 kHz) using an oscilloscope. Frequencies in the ranges 1-10 kHz and 10-125 kHz were investigated respectively. Experimental results showed that there was an obvious correlation between the high-frequency signal and the laser power, while the high-frequency signal was not sensitive to changes in welding speed. In particular, when the defocus position was changed, only a high frequency of the visible light signal was observed, while the high frequency of the laser reflection signal remained unchanged. The basic correlation between optical features and welding status during the laser welding process is specified, which helps to provide a new research focus for investigating the stability of welding status.

  16. An interferometric fiber optic hydrophone with large upper limit of dynamic range

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Kan, Baoxi; Zheng, Baichao; Wang, Xuefeng; Zhang, Haiyan; Hao, Liangbin; Wang, Hailiang; Hou, Zhenxing; Yu, Wenpeng

    2017-10-01

    Interferometric fiber optic hydrophone based on heterodyne detection is used to measure the missile dropping point in the sea. The signal caused by the missile dropping in the water will be too large to be detected, so it is necessary to boost the upper limit of dynamic range (ULODR) of fiber optic hydrophone. In this article we analysis the factors which influence the ULODR of fiber optic hydrophone based on heterodyne detection, the ULODR is decided by the sampling frequency fsam and the heterodyne frequency Δf. The sampling frequency and the heterodyne frequency should be satisfied with the Nyquist sampling theorem which fsam will be two times larger than Δf, in this condition the ULODR is depended on the heterodyne frequency. In order to enlarge the ULODR, the Nyquist sampling theorem was broken, and we proposed a fiber optic hydrophone which the heterodyne frequency is larger than the sampling frequency. Both the simulation and experiment were done in this paper, the consequences are similar: When the sampling frequency is 100kHz, the ULODR of large heterodyne frequency fiber optic hydrophone is 2.6 times larger than that of the small heterodyne frequency fiber optic hydrophone. As the heterodyne frequency is larger than the sampling frequency, the ULODR is depended on the sampling frequency. If the sampling frequency was set at 2MHz, the ULODR of fiber optic hydrophone based on heterodyne detection will be boosted to 1000rad at 1kHz, and this large heterodyne fiber optic hydrophone can be applied to locate the drop position of the missile in the sea.

  17. An advanced real-time digital signal processing system for linear systems emulation, with special emphasis on network and acoustic response characterization

    NASA Astrophysics Data System (ADS)

    Gaydecki, Patrick; Fernandes, Bosco

    2003-11-01

    A fast digital signal processing (DSP) system is described that can perform real-time emulation of a wide variety of linear audio-bandwidth systems and networks, such as reverberant spaces, musical instrument bodies and very high order filter networks. The hardware design is based upon a Motorola DSP56309 operating at 110 million multiplication-accumulations per second and a dual-channel 24 bit codec with a maximum sampling frequency of 192 kHz. High level software has been developed to express complex vector frequency responses as both infinite impulse response (IIR) and finite impulse response (FIR) coefficients, in a form suitable for real-time convolution by the firmware installed in the DSP system memory. An algorithm has also been devised to express IIR filters as equivalent FIR structures, thereby obviating the potential instabilities associated with recursive equations and negating the traditional deficiencies of FIR filters respecting equivalent analogue designs. The speed and dynamic range of the system is such that, when sampling at 48 kHz, the frequency response can be specified to a spectral precision of 22 Hz when sampling at 10 kHz, this resolution increases to 0.9 Hz. Moreover, it is also possible to control the phase of any frequency band with a theoretical precision of 10-5 degrees in all cases. The system has been applied in the study of analogue filter networks, real-time Hilbert transformation, phase-shift systems and musical instrument body emulation, where it is providing valuable new insights into the understanding of psychoacoustic mechanisms.

  18. Spectro-temporal characteristics of speech at high frequencies, and the potential for restoration of audibility to people with mild-to-moderate hearing loss.

    PubMed

    Moore, Brian C J; Stone, Michael A; Füllgrabe, Christian; Glasberg, Brian R; Puria, Sunil

    2008-12-01

    It is possible for auditory prostheses to provide amplification for frequencies above 6 kHz. However, most current hearing-aid fitting procedures do not give recommended gains for such high frequencies. This study was intended to provide information that could be useful in quantifying appropriate high-frequency gains, and in establishing the population of hearing-impaired people who might benefit from such amplification. The study had two parts. In the first part, wide-bandwidth recordings of normal conversational speech were obtained from a sample of male and female talkers. The recordings were used to determine the mean spectral shape over a wide frequency range, and to determine the distribution of levels (the speech dynamic range) as a function of center frequency. In the second part, audiometric thresholds were measured for frequencies of 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, and 12.5 kHz for both ears of 31 people selected to have mild or moderate cochlear hearing loss. The hearing loss was never greater than 70 dB for any frequency up to 4 kHz. The mean spectrum level of the speech fell progressively with increasing center frequency above about 0.5 kHz. For speech with an overall level of 65 dB SPL, the mean 1/3-octave level was 49 and 37 dB SPL for center frequencies of 1 and 10 kHz, respectively. The dynamic range of the speech was similar for center frequencies of 1 and 10 kHz. The part of the dynamic range below the root-mean-square level was larger than reported in previous studies. The mean audiometric thresholds at high frequencies (10 and 12.5 kHz) were relatively high (69 and 77 dB HL, respectively), even though the mean thresholds for frequencies below 4 kHz were 41 dB HL or better. To partially restore audibility for a hearing loss of 65 dB at 10 kHz would require an effective insertion gain of about 36 dB at 10 kHz. With this gain, audibility could be (partly) restored for 25 of the 62 ears assessed.

  19. Nonlinear Stress/Strain Behavior of a Synthetic Porous Medium at Seismic Frequencies

    NASA Astrophysics Data System (ADS)

    Roberts, P. M.; Ibrahim, R. H.

    2008-12-01

    Laboratory experiments on porous core samples have shown that seismic-band (100 Hz or less) mechanical, axial stress/strain cycling of the porous matrix can influence the transport behavior of fluids and suspended particles during steady-state fluid flow through the cores. In conjunction with these stimulated transport experiments, measurements of the applied dynamic axial stress/strain were made to investigate the nonlinear mechanical response of porous media for a poorly explored range of frequencies from 1 to 40 Hz. A unique core-holder apparatus that applies low-frequency mechanical stress/strain to 2.54-cm-diameter porous samples during constant-rate fluid flow was used for these experiments. Applied stress was measured with a load cell in series with the source and porous sample, and the resulting strain was measured with an LVDT attached to the core face. A synthetic porous system consisting of packed 1-mm-diameter glass beads was used to investigate both stress/strain and stimulated mass-transport behavior under idealized conditions. The bead pack was placed in a rubber sleeve and static confining stresses of 2.4 MPa radial and 1.7 MPa axial were applied to the sample. Sinusoidal stress oscillations were applied to the sample at 1 to 40 Hz over a range of RMS stress amplitude from 37 to 275 kPa. Dynamic stress/strain was measured before and after the core was saturated with deionized water. The slope of the linear portion of each stress/strain hysteresis loop was used to estimate Young's modulus as a function of frequency and amplitude for both the dry and wet sample. The modulus was observed to increase after the dry sample was saturated. For both dry and wet cases, the modulus decreased with increasing dynamic RMS stress amplitude at a constant frequency of 23 Hz. At constant RMS stress amplitude, the modulus increased with increasing frequency for the wet sample but remained constant for the dry sample. The observed nonlinear behavior of Young's modulus and the dependence of stress/strain hysteresis on strain amplitude and frequency have implications on how seismic waves can influence the mechanical properties of granular porous materials in the Earth. This work was funded by the U.S. Department of Energy Basic Energy Sciences Program under the Los Alamos National Laboratory contract no. DE-AC52-06NA25396.

  20. The effect of beat frequency on eye movements during free viewing.

    PubMed

    Maróti, Emese; Knakker, Balázs; Vidnyánszky, Zoltán; Weiss, Béla

    2017-02-01

    External periodic stimuli entrain brain oscillations and affect perception and attention. It has been shown that background music can change oculomotor behavior and facilitate detection of visual objects occurring on the musical beat. However, whether musical beats in different tempi modulate information sampling differently during natural viewing remains to be explored. Here we addressed this question by investigating how listening to naturalistic drum grooves in two different tempi affects eye movements of participants viewing natural scenes on a computer screen. We found that the beat frequency of the drum grooves modulated the rate of eye movements: fixation durations were increased at the lower beat frequency (1.7Hz) as compared to the higher beat frequency (2.4Hz) and no music conditions. Correspondingly, estimated visual sampling frequency decreased as fixation durations increased with lower beat frequency. These results imply that slow musical beats can retard sampling of visual information during natural viewing by increasing fixation durations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Comparison of morphology and phase composition of hydroxyapatite nanoparticles sonochemically synthesized with dual- or single-frequency ultrasonic reactor

    NASA Astrophysics Data System (ADS)

    Deng, Shi-ting; Yu, Hong; Liu, Di; Bi, Yong-guang

    2017-10-01

    To investigate how a dual- or single-frequency ultrasonic reactor changes the morphology and phase composition of hydroxyapatite nanoparticles (nHAPs), we designed and constructed the preparation of nHAPs using dual- or single-frequency ultrasonic devices, i.e., the single frequency ultrasonic generator with ultrasonic horn (25 kHz), the ultrasonic bath (40 kHz) and the dual-frequency sonochemical systems combined with the ultrasonic horn and the ultrasonic bath simultaneously (25 + 40 kHz). The results showed that the sonicated samples displayed a more uniform shape with less agglomeration than non-sonicated sample. The rod-shaped particles with 1.66 stoichiometry and without a second phase were synthesized successfully in the ultrasonic bath or horn systems. The nHAPs obtained from the dual-frequency ultrasonic systems exhibited a regular rod-shaped structure with better dispersion and more uniform shapes than those of obtained in either ultrasonic bath or horn systems. Additionally, the size of rod-shaped particles obtained in the dual-frequency ultrasound with a mean width of 35 nm and a mean length of 64 nm was smaller than other samples. A possible mechanism is that the dual-frequency ultrasound significantly enhances the cavitation yield over single frequency ultrasound and thus improves the dispersion of particles and reduces the size of the crystals. In addition, irregular holes can be observed in the nanoparticles obtained in the dual-frequency ultrasound. Therefore, the dual-frequency ultrasonic systems are expected to become a convenient, efficient and environmentally friendly synthetic technology to obtain well-defined nHAPs for specific biomedical applications.

  2. Modulation infrared thermometry of caloric effects at up to kHz frequencies

    NASA Astrophysics Data System (ADS)

    Döntgen, Jago; Rudolph, Jörg; Waske, Anja; Hägele, Daniel

    2018-03-01

    We present a novel non-contact method for the direct measurement of caloric effects in low volume samples. The adiabatic temperature change ΔT of a magnetocaloric sample is very sensitively determined from thermal radiation. Rapid modulation of ΔT is induced by an oscillating external magnetic field. Detection of thermal radiation with a mercury-cadmium-telluride detector allows for measurements at field frequencies exceeding 1 kHz. In contrast to thermoacoustic methods, our method can be employed in vacuum which enhances adiabatic conditions especially in the case of small volume samples. Systematic measurements of the magnetocaloric effect as a function of temperature, magnetic field amplitude, and modulation frequency give a detailed picture of the thermal behavior of the sample. Highly sensitive measurements of the magnetocaloric effect are demonstrated on a 2 mm thick sample of gadolinium and a 60 μm thick Fe80B12Nb8 ribbon.

  3. Enhanced Synthesis of Carbon Nanomaterials Using Acoustically Excited Methane Diffusion Flames

    PubMed Central

    Hou, Shuhn-Shyurng; Chen, Kuan-Ming; Yang, Zong-Yun; Lin, Ta-Hui

    2015-01-01

    Acoustically modulated methane jet diffusion flames were used to enhance carbon nanostructure synthesis. A catalytic nickel substrate was employed to collect the deposit materials at sampling position z = 10 mm above the burner exit. The fabrication of carbon nano-onions (CNOs) and carbon nanotubes (CNTs) was significantly enhanced by acoustic excitation at frequencies near the natural flickering frequency (ƒ = 20 Hz) and near the acoustically resonant frequency (ƒ = 90 Hz), respectively. At these characteristic frequencies, flow mixing was markedly enhanced by acoustic excitation, and a flame structure with a bright slender core flame was generated, which provided a favorable flame environment for the growth of carbon nanomaterials. The production rate of CNOs was high at 20 Hz (near the natural flickering frequency), at which the gas temperature was about 680 °C. Additionally, a quantity of CNTs was obtained at 70–95 Hz, near the acoustically resonant frequency, at which the gas temperature was between 665 and 830 °C. However, no carbon nanomaterials were synthesized at other frequencies. The enhanced synthesis of CNOs and CNTs is attributed to the strong mixing of the fuel and oxidizer due to the acoustic excitation at resonant frequencies. PMID:28793473

  4. No attentional capture from invisible flicker

    PubMed Central

    Alais, David; Locke, Shannon M.; Leung, Johahn; Van der Burg, Erik

    2016-01-01

    We tested whether fast flicker can capture attention using eight flicker frequencies from 20–96 Hz, including several too high to be perceived (>50 Hz). Using a 480 Hz visual display rate, we presented smoothly sampled sinusoidal temporal modulations at: 20, 30, 40, 48, 60, 69, 80, and 96 Hz. We first established flicker detection rates for each frequency. Performance was at or near ceiling until 48 Hz and dropped sharply to chance level at 60 Hz and above. We then presented the same flickering stimuli as pre-cues in a visual search task containing five elements. Flicker location varied randomly and was therefore congruent with target location on 20% of trials. Comparing congruent and incongruent trials revealed a very strong congruency effect (faster search for cued targets) for all detectable frequencies (20–48 Hz) but no effect for faster flicker rates that were detected at chance. This pattern of results (obtained with brief flicker cues: 58 ms) was replicated for long flicker cues (1000 ms) intended to allow for entrainment to the flicker frequency. These results indicate that only visible flicker serves as an exogenous attentional cue and that flicker rates too high to be perceived are completely ineffective. PMID:27377759

  5. Information theoretic measures of network coordination in high-frequency scalp EEG reveal dynamic patterns associated with seizure termination

    PubMed Central

    Stamoulis, Catherine; Schomer, Donald L.; Chang, Bernard S.

    2013-01-01

    How a seizure terminates is still under-studied and, despite its clinical importance, remains an obscure phase of seizure evolution. Recent studies of seizure-related scalp EEGs at frequencies >100 Hz suggest that neural activity, in the form of oscillations and/or neuronal network interactions, may play an important role in preictal/ictal seizure evolution [2, 31]. However, the role of high-frequency activity in seizure termination, is unknown, if it exists at all. Using information theoretic measures of network coordination, this study investigated ictal and immediate postictal neurodynamic interactions encoded in scalp EEGs from a relatively small sample of 8 patients with focal epilepsy and multiple seizures originating in temporal and/or frontal brain regions, at frequencies ≤100 Hz and >100 Hz, respectively. Despite some heterogeneity in the dynamics of these interactions, consistent patterns were also estimated. Specifically, in several seizures, linear or non-linear increase in high-frequency neuronal coordination during ictal intervals, coincided with a corresponding decrease in coordination at frequencies <100 Hz, suggesting a potential interference role of high-frequency activity, to disrupt abnormal ictal synchrony at lower frequencies. These changes in network synchrony started at least 20–30 sec prior to seizure offset, depending on the seizure duration. Opposite patterns were estimated at frequencies ≤100 Hz in several seizures. These results raise the possibility that high-frequency interference may occur in the form of progressive network coordination during the ictal interval, which continues during the postictal interval. This may be one of several possible mechanisms that facilitate seizure termination. In fact, inhibition of pairwise interactions between EEGs by other signals in their spatial neighborhood, quantified by negative interaction information, was estimated at frequencies ≤100 Hz, at least in some seizures. PMID:23608198

  6. ASSESSMENT OF LOW-FREQUENCY HEARING WITH NARROW-BAND CHIRP EVOKED 40-HZ SINUSOIDAL AUDITORY STEADY STATE RESPONSE

    PubMed Central

    Wilson, Uzma S.; Kaf, Wafaa A.; Danesh, Ali A.; Lichtenhan, Jeffery T.

    2016-01-01

    Objective To determine the clinical utility of narrow-band chirp evoked 40-Hz sinusoidal auditory steady state responses (s-ASSR) in the assessment of low-frequency hearing in noisy participants. Design Tone bursts and narrow-band chirps were used to respectively evoke auditory brainstem responses (tb-ABR) and 40-Hz s-ASSR thresholds with the Kalman-weighted filtering technique and were compared to behavioral thresholds at 500, 2000, and 4000 Hz. A repeated measure ANOVA and post-hoc t-tests, and simple regression analyses were performed for each of the three stimulus frequencies. Study Sample Thirty young adults aged 18–25 with normal hearing participated in this study. Results When 4000 equivalent responses averages were used, the range of mean s-ASSR thresholds from 500, 2000, and 4000 Hz were 17–22 dB lower (better) than when 2000 averages were used. The range of mean tb-ABR thresholds were lower by 11–15 dB for 2000 and 4000 Hz when twice as many equivalent response averages were used, while mean tb-ABR thresholds for 500 Hz were indistinguishable regardless of additional response averaging Conclusion Narrow band chirp evoked 40-Hz s-ASSR requires a ~15 dB smaller correction factor than tb-ABR for estimating low-frequency auditory threshold in noisy participants when adequate response averaging is used. PMID:26795555

  7. Evaluation of multiple-frequency, active and passive acoustics as surrogates for bedload transport

    USGS Publications Warehouse

    Wood, Molly S.; Fosness, Ryan L.; Pachman, Gregory; Lorang, Mark; Tonolla, Diego

    2015-01-01

    The use of multiple-frequency, active acoustics through deployment of acoustic Doppler current profilers (ADCPs) shows potential for estimating bedload in selected grain size categories. The U.S. Geological Survey (USGS), in cooperation with the University of Montana (UM), evaluated the use of multiple-frequency, active and passive acoustics as surrogates for bedload transport during a pilot study on the Kootenai River, Idaho, May 17-18, 2012. Four ADCPs with frequencies ranging from 600 to 2000 kHz were used to measure apparent moving bed velocities at 20 stations across the river in conjunction with physical bedload samples. Additionally, UM scientists measured the sound frequencies of moving particles with two hydrophones, considered passive acoustics, along longitudinal transects in the study reach. Some patterns emerged in the preliminary analysis which show promise for future studies. Statistically significant relations were successfully developed between apparent moving bed velocities measured by ADCPs with frequencies 1000 and 1200 kHz and bedload in 0.5 to 2.0 mm grain size categories. The 600 kHz ADCP seemed somewhat sensitive to the movement of gravel bedload in the size range 8.0 to 31.5 mm, but the relation was not statistically significant. The passive hydrophone surveys corroborated the sample results and could be used to map spatial variability in bedload transport and to select a measurement cross-section with moving bedload for active acoustic surveys and physical samples.

  8. Frequency comparison involving the Romanian primary length standard RO.1 within the framework of the EUROMET Project #498

    NASA Astrophysics Data System (ADS)

    Popescu, Gheorghe

    2001-06-01

    An international frequency comparison was carried out at the Bundesamt fuer Eich- und Vermessungswessen (BEV), Vienna, within the framework of the EUROMET Project #498 from August 29 to September 5, 1999. The frequency differences obtained when the RO.1 laser from the National Institute for Laser, Plasma and Radiation Physics (NILPRP), Romania, was compared with five lasers from Austria (BEV1), Czech Republic (PLD1), France (BIPM3), Poland (GUM1) and Hungary (OMH1) are reported. Frequency differences were computed by using the matrix determinations for the group d, e, f, g. Considering the frequency differences measured for a group of three lasers compared to each other, we call the closing frequency the difference between measured and expected frequency difference (resulting from the previous two measurements). For the RO1 laser, when the BIPM3 laser was the reference laser, the closing frequencies range from +8.1 kHz to - 3.8 kHz. The relative Allan standard deviation was used to express the frequency stability and resulted 3.8 parts in 1012 for 100 s sampling time and 14000 s duration of the measurements. The averaged offset frequency relative to the BIPM4 stationary laser was 5.6 kHz and the standard deviation was 9.9 kHz.

  9. The effects of high-frequency oscillations in hippocampal electrical activities on the classification of epileptiform events using artificial neural networks

    NASA Astrophysics Data System (ADS)

    Chiu, Alan W. L.; Jahromi, Shokrollah S.; Khosravani, Houman; Carlen, Peter L.; Bardakjian, Berj L.

    2006-03-01

    The existence of hippocampal high-frequency electrical activities (greater than 100 Hz) during the progression of seizure episodes in both human and animal experimental models of epilepsy has been well documented (Bragin A, Engel J, Wilson C L, Fried I and Buzsáki G 1999 Hippocampus 9 137-42 Khosravani H, Pinnegar C R, Mitchell J R, Bardakjian B L, Federico P and Carlen P L 2005 Epilepsia 46 1-10). However, this information has not been studied between successive seizure episodes or utilized in the application of seizure classification. In this study, we examine the dynamical changes of an in vitro low Mg2+ rat hippocampal slice model of epilepsy at different frequency bands using wavelet transforms and artificial neural networks. By dividing the time-frequency spectrum of each seizure-like event (SLE) into frequency bins, we can analyze their burst-to-burst variations within individual SLEs as well as between successive SLE episodes. Wavelet energy and wavelet entropy are estimated for intracellular and extracellular electrical recordings using sufficiently high sampling rates (10 kHz). We demonstrate that the activities of high-frequency oscillations in the 100-400 Hz range increase as the slice approaches SLE onsets and in later episodes of SLEs. Utilizing the time-dependent relationship between different frequency bands, we can achieve frequency-dependent state classification. We demonstrate that activities in the frequency range 100-400 Hz are critical for the accurate classification of the different states of electrographic seizure-like episodes (containing interictal, preictal and ictal states) in brain slices undergoing recurrent spontaneous SLEs. While preictal activities can be classified with an average accuracy of 77.4 ± 6.7% utilizing the frequency spectrum in the range 0-400 Hz, we can also achieve a similar level of accuracy by using a nonlinear relationship between 100-400 Hz and <4 Hz frequency bands only.

  10. Inferior frontal sensitivity to common speech sounds is amplified by increasing word intelligibility.

    PubMed

    Vaden, Kenneth I; Kuchinsky, Stefanie E; Keren, Noam I; Harris, Kelly C; Ahlstrom, Jayne B; Dubno, Judy R; Eckert, Mark A

    2011-11-01

    The left inferior frontal gyrus (LIFG) exhibits increased responsiveness when people listen to words composed of speech sounds that frequently co-occur in the English language (Vaden, Piquado, & Hickok, 2011), termed high phonotactic frequency (Vitevitch & Luce, 1998). The current experiment aimed to further characterize the relation of phonotactic frequency to LIFG activity by manipulating word intelligibility in participants of varying age. Thirty six native English speakers, 19-79 years old (mean=50.5, sd=21.0) indicated with a button press whether they recognized 120 binaurally presented consonant-vowel-consonant words during a sparse sampling fMRI experiment (TR=8 s). Word intelligibility was manipulated by low-pass filtering (cutoff frequencies of 400 Hz, 1000 Hz, 1600 Hz, and 3150 Hz). Group analyses revealed a significant positive correlation between phonotactic frequency and LIFG activity, which was unaffected by age and hearing thresholds. A region of interest analysis revealed that the relation between phonotactic frequency and LIFG activity was significantly strengthened for the most intelligible words (low-pass cutoff at 3150 Hz). These results suggest that the responsiveness of the left inferior frontal cortex to phonotactic frequency reflects the downstream impact of word recognition rather than support of word recognition, at least when there are no speech production demands. Published by Elsevier Ltd.

  11. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?

    PubMed

    Mahdiani, Shadi; Jeyhani, Vala; Peltokangas, Mikko; Vehkaoja, Antti

    2015-01-01

    With the worldwide growth of mobile wireless technologies, healthcare services can be provided at anytime and anywhere. Usage of wearable wireless physiological monitoring system has been extensively increasing during the last decade. These mobile devices can continuously measure e.g. the heart activity and wirelessly transfer the data to the mobile phone of the patient. One of the significant restrictions for these devices is usage of energy, which leads to requiring low sampling rate. This article is presented in order to investigate the lowest adequate sampling frequency of ECG signal, for achieving accurate enough time domain heart rate variability (HRV) parameters. For this purpose the ECG signals originally measured with high 5 kHz sampling rate were down-sampled to simulate the measurement with lower sampling rate. Down-sampling loses information, decreases temporal accuracy, which was then restored by interpolating the signals to their original sampling rates. The HRV parameters obtained from the ECG signals with lower sampling rates were compared. The results represent that even when the sampling rate of ECG signal is equal to 50 Hz, the HRV parameters are almost accurate with a reasonable error.

  12. Studies on frequency dependent electrical and dielectric properties of sintered zinc oxide pellets: effects of Al-doping

    NASA Astrophysics Data System (ADS)

    Tewari, S.; Ghosh, A.; Bhattacharjee, A.

    2016-11-01

    Sintered pellets of zinc oxide (ZnO), both undoped and Al-doped are prepared through a chemical process. Dopant concentration of Aluminium in ZnO [Al/Zn in weight percentage (wt%)] is varied from 0 to 3 wt%. After synthesis structural characterisation of the samples are performed with XRD and SEM-EDAX which confirm that all the samples are of ZnO having polycrystalline nature with particle size from 108.6 to 116 nm. Frequency dependent properties like a.c. conductivity, capacitance, impedance and phase angle are measured in the frequency range 10 Hz to 100 kHz as a function of temperature (in the range 25-150 °C). Nature of a.c. conductivity in these samples indicates hopping type of conduction arising from localised defect states. The frequency and temperature dependent properties under study are found to be as per correlated barrier hoping model. Dielectric and impedance properties studied in the samples indicate distributed relaxation, showing decrease of relaxation time with temperature.

  13. Influence of a 50 hz extra low frequency electromagnetic field on spermatozoa motility and fertilization rates in rabbits.

    PubMed

    Roychoudhury, Shubhadeep; Jedlicka, Jaroslav; Parkanyi, Vladimir; Rafay, Jan; Ondruska, Lubomir; Massanyi, Peter; Bulla, Jozef

    2009-08-01

    Effects of a 50 Hz extra-low frequency electromagnetic field (ELF EMF) on in vitro rabbit spermatozoa motility were analyzed, as well as the effect on fertilization rates after insemination. Pooled semen samples and a control were exposed to 50 Hz ELF EMF. The difference of the samples of the test groups G1 and G2 with the control group CG (75.56%) for spermatozoa motility were found to be significant (P < 0.01). Differences were significant (P < 0.01) for curvilinear velocity (VCL) between the test group G3 (122.38 microm/s) and the control group CG (112.02 microm/s). Hormonally stimulated adult (9-12 months) females (n = 140) were inseminated with semen samples from G1, G2, G3 and CG (0.88 x 109 spermatozoa/0.5 mL average insemination portion) immediately after ELF EMF exposure and fertilization (kindling) rates were calculated. For the G2 it was 54.28% data indicate 50 Hz ELF EMF induced alterations of spermatozoa motility and kindling rate in rabbits, therefore influencing fertility.

  14. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait

    PubMed Central

    2014-01-01

    Background Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. Methods The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. Results The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. Conclusions The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this variation was related to the method and reference frame used to obtain the joint angles and the accuracy of measurement system. PMID:24684720

  15. A portable system with sample rate of 250 Hz for characterization of knee and hip angles in the sagittal plane during gait.

    PubMed

    Martínez-Solís, Fermín; Claudio-Sánchez, Abraham; Rodríguez-Lelis, José M; Vergara-Limon, Sergio; Olivares-Peregrino, Víctor; Vargas-Treviño, Marciano

    2014-03-31

    Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this variation was related to the method and reference frame used to obtain the joint angles and the accuracy of measurement system.

  16. Intraglomerular inhibition maintains mitral cell response contrast across input frequencies

    PubMed Central

    Shao, Zuoyi; Puche, Adam C.

    2013-01-01

    Odor signals are transmitted to the olfactory bulb by olfactory nerve (ON) synapses onto mitral/tufted cells (MTCs) and external tufted cells (ETCs); ETCs provide additional feed-forward excitation to MTCs. Both are strongly regulated by intraglomerular inhibition that can last up to 1 s and, when blocked, dramatically increases ON-evoked MC spiking. Intraglomerular inhibition thus limits the magnitude and duration of MC spike responses to sensory input. In vivo, sensory input is repetitive, dictated by sniffing rates from 1 to 8 Hz, potentially summing intraglomerular inhibition. To investigate this, we recorded MTC responses to 1- to 8-Hz ON stimulation in slices. Inhibitory postsynaptic current area (charge) following each ON stimulation was unchanged from 1 to 5 Hz and modestly paired-pulse attenuated at 8 Hz, suggesting there is no summation and only limited decrement at the highest input frequencies. Next, we investigated frequency independence of intraglomerular inhibition on MC spiking. MCs respond to single ON shocks with an initial spike burst followed by reduced spiking decaying to baseline. Upon repetitive ON stimulation peak spiking is identical across input frequencies but the ratio of peak-to-minimum rate before the stimulus (max-min) diminishes from 30:1 at 1 Hz to 15:1 at 8 Hz. When intraglomerular inhibition is selectively blocked, peak spike rate is unchanged but trough spiking increases markedly decreasing max-min firing ratios from 30:1 at 1 Hz to 2:1 at 8 Hz. Together, these results suggest intraglomerular inhibition is relatively frequency independent and can “sharpen” MC responses to input across the range of frequencies. This suggests that glomerular circuits can maintain “contrast” in MC encoding during sniff-sampled inputs. PMID:23926045

  17. Intraglomerular inhibition maintains mitral cell response contrast across input frequencies.

    PubMed

    Shao, Zuoyi; Puche, Adam C; Shipley, Michael T

    2013-11-01

    Odor signals are transmitted to the olfactory bulb by olfactory nerve (ON) synapses onto mitral/tufted cells (MTCs) and external tufted cells (ETCs); ETCs provide additional feed-forward excitation to MTCs. Both are strongly regulated by intraglomerular inhibition that can last up to 1 s and, when blocked, dramatically increases ON-evoked MC spiking. Intraglomerular inhibition thus limits the magnitude and duration of MC spike responses to sensory input. In vivo, sensory input is repetitive, dictated by sniffing rates from 1 to 8 Hz, potentially summing intraglomerular inhibition. To investigate this, we recorded MTC responses to 1- to 8-Hz ON stimulation in slices. Inhibitory postsynaptic current area (charge) following each ON stimulation was unchanged from 1 to 5 Hz and modestly paired-pulse attenuated at 8 Hz, suggesting there is no summation and only limited decrement at the highest input frequencies. Next, we investigated frequency independence of intraglomerular inhibition on MC spiking. MCs respond to single ON shocks with an initial spike burst followed by reduced spiking decaying to baseline. Upon repetitive ON stimulation peak spiking is identical across input frequencies but the ratio of peak-to-minimum rate before the stimulus (max-min) diminishes from 30:1 at 1 Hz to 15:1 at 8 Hz. When intraglomerular inhibition is selectively blocked, peak spike rate is unchanged but trough spiking increases markedly decreasing max-min firing ratios from 30:1 at 1 Hz to 2:1 at 8 Hz. Together, these results suggest intraglomerular inhibition is relatively frequency independent and can "sharpen" MC responses to input across the range of frequencies. This suggests that glomerular circuits can maintain "contrast" in MC encoding during sniff-sampled inputs.

  18. High-Resolution Audio with Inaudible High-Frequency Components Induces a Relaxed Attentional State without Conscious Awareness.

    PubMed

    Kuribayashi, Ryuma; Nittono, Hiroshi

    2017-01-01

    High-resolution audio has a higher sampling frequency and a greater bit depth than conventional low-resolution audio such as compact disks. The higher sampling frequency enables inaudible sound components (above 20 kHz) that are cut off in low-resolution audio to be reproduced. Previous studies of high-resolution audio have mainly focused on the effect of such high-frequency components. It is known that alpha-band power in a human electroencephalogram (EEG) is larger when the inaudible high-frequency components are present than when they are absent. Traditionally, alpha-band EEG activity has been associated with arousal level. However, no previous studies have explored whether sound sources with high-frequency components affect the arousal level of listeners. The present study examined this possibility by having 22 participants listen to two types of a 400-s musical excerpt of French Suite No. 5 by J. S. Bach (on cembalo, 24-bit quantization, 192 kHz A/D sampling), with or without inaudible high-frequency components, while performing a visual vigilance task. High-alpha (10.5-13 Hz) and low-beta (13-20 Hz) EEG powers were larger for the excerpt with high-frequency components than for the excerpt without them. Reaction times and error rates did not change during the task and were not different between the excerpts. The amplitude of the P3 component elicited by target stimuli in the vigilance task increased in the second half of the listening period for the excerpt with high-frequency components, whereas no such P3 amplitude change was observed for the other excerpt without them. The participants did not distinguish between these excerpts in terms of sound quality. Only a subjective rating of inactive pleasantness after listening was higher for the excerpt with high-frequency components than for the other excerpt. The present study shows that high-resolution audio that retains high-frequency components has an advantage over similar and indistinguishable digital sound sources in which such components are artificially cut off, suggesting that high-resolution audio with inaudible high-frequency components induces a relaxed attentional state without conscious awareness.

  19. Magnetic force microscopy with frequency-modulated capacitive tip-sample distance control

    NASA Astrophysics Data System (ADS)

    Zhao, X.; Schwenk, J.; Mandru, A. O.; Penedo, M.; Baćani, M.; Marioni, M. A.; Hug, H. J.

    2018-01-01

    In a step towards routinely achieving 10 nm spatial resolution with magnetic force microscopy, we have developed a robust method for active tip-sample distance control based on frequency modulation of the cantilever oscillation. It allows us to keep a well-defined tip-sample distance of the order of 10 nm within better than +/- 0.4 nm precision throughout the measurement even in the presence of energy dissipative processes, and is adequate for single-passage non-contact operation in vacuum. The cantilever is excited mechanically in a phase-locked loop to oscillate at constant amplitude on its first flexural resonance mode. This frequency is modulated by an electrostatic force gradient generated by tip-sample bias oscillating from a few hundred Hz up to a few kHz. The sum of the side bands’ amplitudes is a proxy for the tip-sample distance and can be used for tip-sample distance control. This method can also be extended to other scanning probe microscopy techniques.

  20. Interferometric apparatus and method for detection and characterization of particles using light scattered therefrom

    DOEpatents

    Johnston, Roger G.

    1988-01-01

    Interferometric apparatus and method for detection and characterization of particles using light scattered therefrom. Differential phase measurements on scattered light from particles are possible using the two-frequency Zeeman effect laser which emits two frequencies of radiation 250 kHz apart. Excellent discrimination and reproducibility for various pure pollen and bacterial samples in suspension have been observed with a single polarization element. Additionally, a 250 kHz beat frequency was recorded from an individual particle traversing the focused output from the laser in a flow cytometer.

  1. Apparatus and method for detection and characterization of particles using light scattered therefrom

    DOEpatents

    Johnston, R.G.

    1987-03-23

    Apparatus and method for detection and characterization of particles using light scattered therefrom. Differential phase measurements on scattered light from particles are possible using the two-frequency Zeeman effect laser which emits two frequencies of radiation 250 kHz apart. Excellent discrimination and reproducibility for various pure pollen and bacterial samples in suspension have been observed with a single polarization element. Additionally, a 250 kHz beat frequency was recorded from an individual particle traversing the focused output from the laser in a flow cytometer. 13 figs.

  2. Digital Receiver Phase Meter

    NASA Technical Reports Server (NTRS)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  3. Kerr hysteresis loop tracer with alternate driving magnetic field up to 10 kHz

    NASA Astrophysics Data System (ADS)

    Callegaro, Luca; Fiorini, Carlo; Triggiani, Giacomo; Puppin, Ezio

    1997-07-01

    A magneto-optical Kerr loop tracer for hysteresis loop measurements in thin films with field excitation frequency f0 from 10 mHz to 10 kHz is described. A very high sensitivity is obtained by using an ultrabright light-emitting diode as a low-noise light source and a novel acquisition process. The field is generated with a coil driven by an audio amplifier connected to a free-running oscillator. The conditioned detector output constitutes the magnetization signal (M); the magnetic field (H) is measured with a fast Hall probe. The acquisition electronics are based on a set of sample-and-hold amplifiers which allow the simultaneous sampling of M, H, and dH/dt. Acquisition is driven by a personal computer equipped with a multifunction I/O board. Test results on a 120 nm Fe film on Si substrate are shown. The coercive field of the film increases with frequency and nearly doubles at 10 kHz with respect to dc.

  4. The fine structure of Langmuir waves observed upstream of the bow shock at Venus

    NASA Technical Reports Server (NTRS)

    Hospodarsky, G. B.; Gurnett, D. A.; Kurth, W. S.; Kivelson, M. G.; Strangeway, R. J.; Bolton, S. J.

    1994-01-01

    Highly structured Langmuir waves, also known as electron plasma oscillations, have been observed in the foreshock of Venus using the plasma wave experiment on the Galileo spacecraft during the gravity assist flyby on February 10, 1990. The Galileo wideband sampling system provides digital electric field waveform measurements at sampling rates up to 201,600 samples per second, much higher than any previous instrument of this type. The main Langmuir wave emission band occurs near the local electron plasma frequency, which was approximately 43 kHz. The Langmuir waves are observed to shift above and below the plasma frequency, sometimes by as much as 20 kHz. The shifts in frequency are closely correlated with the downstream distance from the tangent field line, implying that the shifts are controlled by the electron beam velocity. Considerable fine structure is also evident, with time scales as short as 0.15 milliseconds, corresponding to spatial scales of a few tens of Debye lengths. The frequency spectrum often consists of beat-type waveforms, with beat frequencies ranging from 0.2 to 7 kHz, and in a few cases, isolated wavepackets. The peak electric field strengths are approximately 1 mV/m. These field strengths are too small for strongly nonlinear processes to be important. The beat-type waveforms are suggestive of a parametric decay process.

  5. Interplanetary shocks, Plasma waves and turbulence, Kinetic waves and instabilities, STEREO spacecraft

    NASA Astrophysics Data System (ADS)

    Cohen, Z.; Breneman, A. W.; Cattell, C. A.; Davis, L.; Grul, P.; Kersten, K.; Wilson, L. B., III

    2017-12-01

    Determining the role of plasma waves in providing energy dissipation at shock waves is of long-standing interest. Interplanetary (IP) shocks serve as a large database of low Mach number shocks. We examine electric field waveforms captured by the Time Domain Sampler (TDS) on the STEREO spacecraft during the ramps of IP shocks, with emphasis on captures lasting 2.1 seconds. Previous work has used captures of shorter duration (66 and 131 ms on STEREO, and 17 ms on WIND), which allowed for observation of waves with maximum (minimum) frequencies of 125 kHz (15 Hz), 62.5 kHz (8 Hz), and 60 kHz (59 Hz), respectively. The maximum frequencies are comparable to 2-8 times the plasma frequency in the solar wind, enabling observation of Langmuir waves, ion acoustic, and some whistler-mode waves. The 2 second captures resolve lower frequencies ( few Hz), which allows us to analyze packet structure of the whistler-mode waves and some ion acoustic waves. The longer capture time also improves the resolvability of simultaneous wave modes and of waves with frequencies on the order of 10s of Hz. Langmuir waves, however, cannot be identified at this sampling rate, since the plasma frequency is usually higher than 3.9 kHz. IP shocks are identified from multiple databases (Helsinki heliospheric shock database at http://ipshocks.fi, and the STEREO level 3 shock database at ftp://stereoftp.nascom.nasa.gov/pub/ins_data/impact/level3/). Our analysis focuses on TDS captures in shock ramp regions, with ramp durations determined from magnetic field data taken at 8 Hz. Software is used to identify multiple wave modes in any given capture and classify waves as Langmuir, ion acoustic, whistler, lower hybrid, electron cyclotron drift instability, or electrostatic solitary waves. Relevant frequencies are determined from density and magnetic field data collected in situ. Preliminary results suggest that large amplitude (∼ 5 mV/m) ion acoustic waves are most prevalent in the ramp, in agreement with Wilson, et al. Other modes are also observed. Statistical results will be presented and compared with previous studies and theoretical predictions.

  6. STEREO Observations of Waves in the Ramp Regions of Interplanetary Shocks

    NASA Astrophysics Data System (ADS)

    Cohen, Z.; Breneman, A. W.; Cattell, C. A.; Davis, L.; Grul, P.; Kersten, K.; Wilson, L. B., III

    2017-12-01

    Determining the role of plasma waves in providing energy dissipation at shock waves is of long-standing interest. Interplanetary (IP) shocks serve as a large database of low Mach number shocks. We examine electric field waveforms captured by the Time Domain Sampler (TDS) on the STEREO spacecraft during the ramps of IP shocks, with emphasis on captures lasting 2.1 seconds. Previous work has used captures of shorter duration (66 and 131 ms on STEREO, and 17 ms on WIND), which allowed for observation of waves with maximum (minimum) frequencies of 125 kHz (15 Hz), 62.5 kHz (8 Hz), and 60 kHz (59 Hz), respectively. The maximum frequencies are comparable to 2-8 times the plasma frequency in the solar wind, enabling observation of Langmuir waves, ion acoustic, and some whistler-mode waves. The 2 second captures resolve lower frequencies ( few Hz), which allows us to analyze packet structure of the whistler-mode waves and some ion acoustic waves. The longer capture time also improves the resolvability of simultaneous wave modes and of waves with frequencies on the order of 10s of Hz. Langmuir waves, however, cannot be identified at this sampling rate, since the plasma frequency is usually higher than 3.9 kHz. IP shocks are identified from multiple databases (Helsinki heliospheric shock database at http://ipshocks.fi, and the STEREO level 3 shock database at ftp://stereoftp.nascom.nasa.gov/pub/ins_data/impact/level3/). Our analysis focuses on TDS captures in shock ramp regions, with ramp durations determined from magnetic field data taken at 8 Hz. Software is used to identify multiple wave modes in any given capture and classify waves as Langmuir, ion acoustic, whistler, lower hybrid, electron cyclotron drift instability, or electrostatic solitary waves. Relevant frequencies are determined from density and magnetic field data collected in situ. Preliminary results suggest that large amplitude (≥ 5 mV/m) ion acoustic waves are most prevalent in the ramp, in agreement with Wilson, et al. Other modes are also observed. Statistical results will be presented and compared with previous studies and theoretical predictions.

  7. Measurement of Young’s Modulus and Internal Damping of Pork Muscle in Dynamic Mode

    NASA Astrophysics Data System (ADS)

    Chakroun, Moez; Ghozlen, Med Hédi Ben

    2016-09-01

    Automotive shocks involve various tiers’ speed for different human body tissues. Knowing the behavior of these tissues, including muscles, in different vibration frequency is therefore necessary. The muscle has viscoelatic properties. Dynamically, this material has variable mechanical properties depending on the vibration frequency. A novel technique is being employed to examine the variation of the mechanical impedance of pork muscle as a function of frequency. A force is imposed on the lower surface of the sample and acceleration is measured on its upper surface. These two parameters are measured using sensors. The sample is modeled by Kelvin-Voigt model. These measures allow deducing the change in the mechanical impedance modulus (/Zexp/ = /Force: Acceleration/) of pork muscle as a function of vibration frequency. The measured impedance has a resonance of approximately 60Hz. Best-fit parameters of theoretical impedance can be deduced by superposition with the experiment result. The variation of Young’s modulus and internal damping of pig’s muscle as a function of frequency are determined. The results obtained between 5Hz and 30Hz are the same as determined by Aimedieu and al in 2003, therefore validating our technique. The Young’s modulus of muscle increases with the frequency, on the other hand, we note a rating decrease of internal damping.

  8. Freddie Mercury-acoustic analysis of speaking fundamental frequency, vibrato, and subharmonics.

    PubMed

    Herbst, Christian T; Hertegard, Stellan; Zangger-Borch, Daniel; Lindestad, Per-Åke

    2017-04-01

    Freddie Mercury was one of the twentieth century's best-known singers of commercial contemporary music. This study presents an acoustical analysis of his voice production and singing style, based on perceptual and quantitative analysis of publicly available sound recordings. Analysis of six interviews revealed a median speaking fundamental frequency of 117.3 Hz, which is typically found for a baritone voice. Analysis of voice tracks isolated from full band recordings suggested that the singing voice range was 37 semitones within the pitch range of F#2 (about 92.2 Hz) to G5 (about 784 Hz). Evidence for higher phonations up to a fundamental frequency of 1,347 Hz was not deemed reliable. Analysis of 240 sustained notes from 21 a-cappella recordings revealed a surprisingly high mean fundamental frequency modulation rate (vibrato) of 7.0 Hz, reaching the range of vocal tremor. Quantitative analysis utilizing a newly introduced parameter to assess the regularity of vocal vibrato corroborated its perceptually irregular nature, suggesting that vibrato (ir)regularity is a distinctive feature of the singing voice. Imitation of subharmonic phonation samples by a professional rock singer, documented by endoscopic high-speed video at 4,132 frames per second, revealed a 3:1 frequency locked vibratory pattern of vocal folds and ventricular folds.

  9. The network construction of CSELF for earthquake monitoring and its preliminary observation

    NASA Astrophysics Data System (ADS)

    Tang, J.; Zhao, G.; Chen, X.; Bing, H.; Wang, L.; Zhan, Y.; Xiao, Q.; Dong, Z.

    2017-12-01

    The Electromagnetic (EM) anomaly in short-term earthquake precursory is most sensitive physical phenomena. Scientists believe that EM monitoring for earthquake is one of the most promising means of forecasting. However, existing ground-base EM observation confronted with increasing impact cultural noises, and the lack of a frequency range of higher than 1Hz observations. Control source of extremely low frequency (CSELF) EM is a kind of good prospective new approach. It not only has many advantages with high S/N ratio, large coverage area, probing depth ect., thereby facilitating the identification and capture anomaly signal, and it also can be used to study the electromagnetic field variation and to study the crustal medium changes of the electric structure.The first CSELF EM network for earthquake precursory monitoring with 30 observatories in China has been constructed. The observatories distribute in Beijing surrounding area and in the southern part of North-South Seismic Zone. GMS-07 system made by Metronix is equipped at each station. The observation mixed CSELF and nature source, that is, if during the control source is off transmitted, the nature source EM signal will be recorded. In genernal, there are 3 5 frequencies signals in the 0.1-300Hz frequency band will be transmit in every morning and evening in a fixed time (length 2 hours). Besides time, natural field to extend the frequency band (0.001 1000 Hz) will be observed by using 3 sample frequencies, 4096Hz sampling rate for HF, 256Hz for MF and 16Hz for LF. The low frequency band records continuously all-day and the high and medium frequency band use a slices record, the data records by cycling acquisition in every 10 minutes with length of about 4 to 8 seconds and 64 to 128 seconds , respectively. All the data is automatically processed by server installed in the observatory. The EDI file including EM field spectrums and MT responses and time series files will be sent the data center by internet. There shows observation data since the network set up. We get some EM field spectrum variations and the apparent resistivity changes of different frequencies with time on observatories. They show some regular and irregular changes. This study is supported by The ELF Engineering Project of China (15212Z0000001), National Natural Science Foundation of China (41674081) etc.

  10. Information theoretic measures of network coordination in high-frequency scalp EEG reveal dynamic patterns associated with seizure termination.

    PubMed

    Stamoulis, Catherine; Schomer, Donald L; Chang, Bernard S

    2013-08-01

    How a seizure terminates is still under-studied and, despite its clinical importance, remains an obscure phase of seizure evolution. Recent studies of seizure-related scalp EEGs at frequencies >100 Hz suggest that neural activity, in the form of oscillations and/or neuronal network interactions, may play an important role in preictal/ictal seizure evolution (Andrade-Valenca et al., 2011; Stamoulis et al., 2012). However, the role of high-frequency activity in seizure termination, is unknown, if it exists at all. Using information theoretic measures of network coordination, this study investigated ictal and immediate postictal neurodynamic interactions encoded in scalp EEGs from a relatively small sample of 8 patients with focal epilepsy and multiple seizures originating in temporal and/or frontal brain regions, at frequencies ≤ 100 Hz and >100 Hz, respectively. Despite some heterogeneity in the dynamics of these interactions, consistent patterns were also estimated. Specifically, in several seizures, linear or non-linear increase in high-frequency neuronal coordination during ictal intervals, coincided with a corresponding decrease in coordination at frequencies <100 Hz, suggesting a potential interference role of high-frequency activity, to disrupt abnormal ictal synchrony at lower frequencies. These changes in network synchrony started at least 20-30s prior to seizure offset, depending on the seizure duration. Opposite patterns were estimated at frequencies ≤ 100 Hz in several seizures. These results raise the possibility that high-frequency interference may occur in the form of progressive network coordination during the ictal interval, which continues during the postictal interval. This may be one of several possible mechanisms that facilitate seizure termination. In fact, inhibition of pairwise interactions between EEGs by other signals in their spatial neighborhood, quantified by negative interaction information, was estimated at frequencies ≤ 100 Hz, at least in some seizures. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Transport Pathways and Enhancement Mechanisms within Localized and Non-Localized Transport Regions in Skin Treated with Low-Frequency Sonophoresis and Sodium Lauryl Sulfate

    PubMed Central

    Polat, Baris E.; Figueroa, Pedro L.; Blankschtein, Daniel; Langer, Robert

    2011-01-01

    Recent advances in transdermal drug delivery utilizing low-frequency sonophoresis (LFS) and sodium lauryl sulfate (SLS) have revealed that skin permeability enhancement is not homogenous across the skin surface. Instead, highly perturbed skin regions, known as localized transport regions (LTRs), exist. Despite these findings, little research has been conducted to identify intrinsic properties and formation mechanisms of LTRs and the surrounding less-perturbed non-LTRs. By independently analyzing LTR, non-LTR, and total skin samples treated at multiple LFS frequencies, we found that the pore radii (rpore) within non-LTRs are frequency-independent, ranging from 18.2 – 18.5 Å, but significantly larger than rpore of native skin samples (13.6 Å). Conversely, rpore within LTRs increases significantly with decreasing frequency from 161 Å, to 276 Å, and to ∞ (>300Å) for LFS/SLS-treated skin at 60 kHz, 40 kHz, and 20 kHz, respectively. Our findings suggest that different mechanisms contribute to skin permeability enhancement within each skin region. We propose that the enhancement mechanism within LTRs is the frequency-dependent process of cavitation-induced microjet collapse at the skin surface, while the increased rpore values in non-LTRs are likely due to SLS perturbation, with enhanced penetration of SLS into the skin resulting from the frequency-independent process of microstreaming. PMID:20740667

  12. Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples.

    PubMed

    Hong, Hyobong; Lim, Eul-Gyoon; Jeong, Jae-Chan; Chang, Jiho; Shin, Sung-Woong; Krause, Hans-Joachim

    2016-06-09

    The setup of a planar Frequency Mixing Magnetic Detection (p-FMMD) scanner for performing Magnetic Particles Imaging (MPI) of flat samples is presented. It consists of two magnetic measurement heads on both sides of the sample mounted on the legs of a u-shaped support. The sample is locally exposed to a magnetic excitation field consisting of two distinct frequencies, a stronger component at about 77 kHz and a weaker field at 61 Hz. The nonlinear magnetization characteristics of superparamagnetic particles give rise to the generation of intermodulation products. A selected sum-frequency component of the high and low frequency magnetic field incident on the magnetically nonlinear particles is recorded by a demodulation electronics. In contrast to a conventional MPI scanner, p-FMMD does not require the application of a strong magnetic field to the whole sample because mixing of the two frequencies occurs locally. Thus, the lateral dimensions of the sample are just limited by the scanning range and the supports. However, the sample height determines the spatial resolution. In the current setup it is limited to 2 mm. As examples, we present two 20 mm × 25 mm p-FMMD images acquired from samples with 1 µm diameter maghemite particles in silanol matrix and with 50 nm magnetite particles in aminosilane matrix. The results show that the novel MPI scanner can be applied for analysis of thin biological samples and for medical diagnostic purposes.

  13. Investigation of dielectric properties of polymer composites reinforced with carbon nanotubes in the frequency band of 0.01 Hz - 10 MHz

    NASA Astrophysics Data System (ADS)

    Goshev, A. A.; Eseev, M. K.; Kapustin, S. N.; Vinnik, L. N.; Volkov, A. S.

    2016-08-01

    The goal of this work is experimental study of dielectric properties of polymer nanocomposites reinforced with multiwalled carbon nanotubes (MWCNTs) in alternating electric field in low frequency band of 0.01 Hz - 10 MHz. We investigated the influence, functionalization degree, aspect ratio, concentration of carbon nanotubes (CNTs) on dielectric properties of polymer sample. We also studied the dependence of dielectric properties on the polymerization temperature. The dependence of CNTs agglomeration on sample polymerization temperature and temperature's influence on conductivity has been shown. We conducted model calculation of percolation threshold and figured out its dependence on CNTs aspect ratio.

  14. Dielectric studies of the paracetamol-lenticular tissue interactions.

    PubMed

    Marzec, E; Olszewski, J; Grześkowiak, E; Kamińska, A; Bienert, A; Iwanik, K

    2011-05-01

    This paper reports on the effect of paracetamol on the dielectric behavior of the rabbit lens. Measurements were performed over the frequency range of 100 Hz-100 kHz in air and at the temperature of 35°C. The frequency dependencies of the relative permittivity and dielectric loss for the control and paracetamol-control lenses are described in terms of a power-low, Debye and Cole-Cole relations. The effect of paracetamol on the dielectric properties of the lens is visible in the lower values of the relative permittivity than those for the control sample at the same frequency. In addition, the relaxations around 18 and 46 kHz for the paracetamol-control lens are shifted to lower frequencies compared with the control lens. The results of this work indicate that the present method is useful in detection of the lens toxicity elicited by overdoses of paracetamol in animal. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. The effect of sampling rate on interpretation of the temporal characteristics of radiative and convective heating in wildland flames

    Treesearch

    David Frankman; Brent W. Webb; Bret W. Butler; Daniel Jimenez; Michael Harrington

    2012-01-01

    Time-resolved radiative and convective heating measurements were collected on a prescribed burn in coniferous fuels at a sampling frequency of 500 Hz. Evaluation of the data in the time and frequency domain indicate that this sampling rate was sufficient to capture the temporal fluctuations of radiative and convective heating. The convective heating signal contained...

  16. Modeling the high-frequency complex modulus of silicone rubber using standing Lamb waves and an inverse finite element method.

    PubMed

    Jonsson, Ulf; Lindahl, Olof; Andersson, Britt

    2014-12-01

    To gain an understanding of the high-frequency elastic properties of silicone rubber, a finite element model of a cylindrical piezoelectric element, in contact with a silicone rubber disk, was constructed. The frequency-dependent elastic modulus of the silicone rubber was modeled by a fourparameter fractional derivative viscoelastic model in the 100 to 250 kHz frequency range. The calculations were carried out in the range of the first radial resonance frequency of the sensor. At the resonance, the hyperelastic effect of the silicone rubber was modeled by a hyperelastic compensating function. The calculated response was matched to the measured response by using the transitional peaks in the impedance spectrum that originates from the switching of standing Lamb wave modes in the silicone rubber. To validate the results, the impedance responses of three 5-mm-thick silicone rubber disks, with different radial lengths, were measured. The calculated and measured transitional frequencies have been compared in detail. The comparison showed very good agreement, with average relative differences of 0.7%, 0.6%, and 0.7% for the silicone rubber samples with radial lengths of 38.0, 21.4, and 11.0 mm, respectively. The average complex elastic moduli of the samples were (0.97 + 0.009i) GPa at 100 kHz and (0.97 + 0.005i) GPa at 250 kHz.

  17. Efficient waveform tomography for lithospheric imaging: implications for realistic, two-dimensional acquisition geometries and low-frequency data

    NASA Astrophysics Data System (ADS)

    Brenders, A. J.; Pratt, R. G.

    2007-01-01

    We provide a series of numerical experiments designed to test waveform tomography under (i) a reduction in the number of input data frequency components (`efficient' waveform tomography), (ii) sparse spatial subsampling of the input data and (iii) an increase in the minimum data frequency used. These results extend the waveform tomography results of a companion paper, using the same third-party, 2-D, wide-angle, synthetic viscoelastic seismic data, computed in a crustal geology model 250 km long and 40 km deep, with heterogeneous P-velocity, S-velocity, density and Q-factor structure. Accurate velocity models were obtained using efficient waveform tomography and only four carefully selected frequency components of the input data: 0.8, 1.7, 3.6 and 7.0 Hz. This strategy avoids the spectral redundancy present in `full' waveform tomography, and yields results that are comparable with those in the companion paper for an 88 per cent decrease in total computational cost. Because we use acoustic waveform tomography, the results further justify the use of the acoustic wave equation in calculating P-wave velocity models from viscoelastic data. The effect of using sparse survey geometries with efficient waveform tomography were investigated for both increased receiver spacing, and increased source spacing. Sampling theory formally requires spatial sampling at maximum interval of one half-wavelength (2.5 km at 0.8 Hz): For data with receivers every 0.9 km (conforming to this criterion), artefacts in the tomographic images were still minimal when the source spacing was as large as 7.6 km (three times the theoretical maximum). Larger source spacings led to an unacceptable degradation of the results. When increasing the starting frequency, image quality was progressively degraded. Acceptable image quality within the central portion of the model was nevertheless achieved using starting frequencies up to 3.0 Hz. At 3.0 Hz the maximum theoretical sample interval is reduced to 0.67 km due to the decreased wavelengths; the available sources were spaced every 5.0 km (more than seven times the theoretical maximum), and receivers were spaced every 0.9 km (1.3 times the theoretical maximum). Higher starting frequencies than 3.0 Hz again led to unacceptable degradation of the results.

  18. An acoustical assessment of pitch-matching accuracy in relation to speech frequency, speech frequency range, age and gender in preschool children

    NASA Astrophysics Data System (ADS)

    Trollinger, Valerie L.

    This study investigated the relationship between acoustical measurement of singing accuracy in relationship to speech fundamental frequency, speech fundamental frequency range, age and gender in preschool-aged children. Seventy subjects from Southeastern Pennsylvania; the San Francisco Bay Area, California; and Terre Haute, Indiana, participated in the study. Speech frequency was measured by having the subjects participate in spontaneous and guided speech activities with the researcher, with 18 diverse samples extracted from each subject's recording for acoustical analysis for fundamental frequency in Hz with the CSpeech computer program. The fundamental frequencies were averaged together to derive a mean speech frequency score for each subject. Speech range was calculated by subtracting the lowest fundamental frequency produced from the highest fundamental frequency produced, resulting in a speech range measured in increments of Hz. Singing accuracy was measured by having the subjects each echo-sing six randomized patterns using the pitches Middle C, D, E, F♯, G and A (440), using the solfege syllables of Do and Re, which were recorded by a 5-year-old female model. For each subject, 18 samples of singing were recorded. All samples were analyzed by the CSpeech for fundamental frequency. For each subject, deviation scores in Hz were derived by calculating the difference between what the model sang in Hz and what the subject sang in response in Hz. Individual scores for each child consisted of an overall mean total deviation frequency, mean frequency deviations for each pattern, and mean frequency deviation for each pitch. Pearson correlations, MANOVA and ANOVA analyses, Multiple Regressions and Discriminant Analysis revealed the following findings: (1) moderate but significant (p < .001) relationships emerged between mean speech frequency and the ability to sing the pitches E, F♯, G and A in the study; (2) mean speech frequency also emerged as the strongest predictor of subjects' ability to sing the notes E and F♯; (3) mean speech frequency correlated moderately and significantly (p < .001) with sharpness and flatness of singing response accuracy in Hz; (4) speech range was the strongest predictor of singing accuracy for the pitches G and A in the study (p < .001); (5) gender emerged as a significant, but not the strongest, predictor for ability to sing the pitches in the study above C and D; (6) gender did not correlate with mean speech frequency and speech range; (7) age in months emerged as a low but significant predictor of ability to sing the lower notes (C and D) in the study; (8) age correlated significantly but negatively low (r = -.23, p < .05, two-tailed) with mean speech frequency; and (9) age did not emerge as a significant predictor of overall singing accuracy. Ancillary findings indicated that there were significant differences in singing accuracy based on geographic location by gender, and that siblings and fraternal twins in the study generally performed similarly. In addition, reliability for using the CSpeech for acoustical analysis revealed test/retest correlations of .99, with one exception at .94. Based on these results, suggestions were made concerning future research concerned with studying the use of voice in speech and how it may affect singing development, overall use in singing, and pitch-matching accuracy.

  19. Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

    NASA Technical Reports Server (NTRS)

    Ashpis, David E.; Laun, Matthew C.

    2014-01-01

    We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

  20. Influence of thermodynamic properties of a thermo-acoustic emitter on the efficiency of thermal airborne ultrasound generation.

    PubMed

    Daschewski, M; Kreutzbruck, M; Prager, J

    2015-12-01

    In this work we experimentally verify the theoretical prediction of the recently published Energy Density Fluctuation Model (EDF-model) of thermo-acoustic sound generation. Particularly, we investigate experimentally the influence of thermal inertia of an electrically conductive film on the efficiency of thermal airborne ultrasound generation predicted by the EDF-model. Unlike widely used theories, the EDF-model predicts that the thermal inertia of the electrically conductive film is a frequency-dependent parameter. Its influence grows non-linearly with the increase of excitation frequency and reduces the efficiency of the ultrasound generation. Thus, this parameter is the major limiting factor for the efficient thermal airborne ultrasound generation in the MHz-range. To verify this theoretical prediction experimentally, five thermo-acoustic emitter samples consisting of Indium-Tin-Oxide (ITO) coatings of different thicknesses (from 65 nm to 1.44 μm) on quartz glass substrates were tested for airborne ultrasound generation in a frequency range from 10 kHz to 800 kHz. For the measurement of thermally generated sound pressures a laser Doppler vibrometer combined with a 12 μm thin polyethylene foil was used as the sound pressure detector. All tested thermo-acoustic emitter samples showed a resonance-free frequency response in the entire tested frequency range. The thermal inertia of the heat producing film acts as a low-pass filter and reduces the generated sound pressure with the increasing excitation frequency and the ITO film thickness. The difference of generated sound pressure levels for samples with 65 nm and 1.44 μm thickness is in the order of about 6 dB at 50 kHz and of about 12 dB at 500 kHz. A comparison of sound pressure levels measured experimentally and those predicted by the EDF-model shows for all tested emitter samples a relative error of less than ±6%. Thus, experimental results confirm the prediction of the EDF-model and show that the model can be applied for design and optimization of thermo-acoustic airborne ultrasound emitters. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Wire Arc Additive Manufacturing of AZ31 Magnesium Alloy: Grain Refinement by Adjusting Pulse Frequency.

    PubMed

    Guo, Jing; Zhou, Yong; Liu, Changmeng; Wu, Qianru; Chen, Xianping; Lu, Jiping

    2016-10-09

    Wire arc additive manufacturing (WAAM) offers a potential approach to fabricate large-scale magnesium alloy components with low cost and high efficiency, although this topic is yet to be reported in literature. In this study, WAAM is preliminarily applied to fabricate AZ31 magnesium. Fully dense AZ31 magnesium alloy components are successfully obtained. Meanwhile, to refine grains and obtain good mechanical properties, the effects of pulse frequency (1, 2, 5, 10, 100, and 500 Hz) on the macrostructure, microstructure and tensile properties are investigated. The results indicate that pulse frequency can result in the change of weld pool oscillations and cooling rate. This further leads to the change of the grain size, grain shape, as well as the tensile properties. Meanwhile, due to the resonance of the weld pool at 5 Hz and 10 Hz, the samples have poor geometry accuracy but contain finer equiaxed grains (21 μm) and exhibit higher ultimate tensile strength (260 MPa) and yield strength (102 MPa), which are similar to those of the forged AZ31 alloy. Moreover, the elongation of all samples is above 23%.

  2. Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H 2O and CO 2

    DOE PAGES

    Metzger, Stefan; Burba, George; Burns, Sean P.; ...

    2016-03-31

    Several initiatives are currently emerging to observe the exchange of energy and matter between the earth's surface and atmosphere standardized over larger space and time domains. For example, the National Ecological Observatory Network (NEON) and the Integrated Carbon Observing System (ICOS) are set to provide the ability of unbiased ecological inference across ecoclimatic zones and decades by deploying highly scalable and robust instruments and data processing. In the construction of these observatories, enclosed infrared gas analyzers are widely employed for eddy covariance applications. While these sensors represent a substantial improvement compared to their open- and closed-path predecessors, remaining high-frequency attenuation variesmore » with site properties and gas sampling systems, and requires correction. Here, we show that components of the gas sampling system can substantially contribute to such high-frequency attenuation, but their effects can be significantly reduced by careful system design. From laboratory tests we determine the frequency at which signal attenuation reaches 50 % for individual parts of the gas sampling system. For different models of rain caps and particulate filters, this frequency falls into ranges of 2.5–16.5 Hz for CO 2, 2.4–14.3 Hz for H 2O, and 8.3–21.8 Hz for CO 2, 1.4–19.9 Hz for H 2O, respectively. A short and thin stainless steel intake tube was found to not limit frequency response, with 50 % attenuation occurring at frequencies well above 10 Hz for both H 2O and CO 2. From field tests we found that heating the intake tube and particulate filter continuously with 4 W was effective, and reduced the occurrence of problematic relative humidity levels (RH > 60 %) by 50 % in the infrared gas analyzer cell. No further improvement of H 2O frequency response was found for heating in excess of 4 W. These laboratory and field tests were reconciled using resistor–capacitor theory, and NEON's final gas sampling system was developed on this basis. The design consists of the stainless steel intake tube, a pleated mesh particulate filter and a low-volume rain cap in combination with 4 W of heating and insulation. In comparison to the original design, this reduced the high-frequency attenuation for H 2O by ≈ 3/4, and the remaining cospectral correction did not exceed 3 %, even at high relative humidity (95 %). The standardized design can be used across a wide range of ecoclimates and site layouts, and maximizes practicability due to minimal flow resistance and maintenance needs. Lastly, due to minimal high-frequency spectral loss, it supports the routine application of adaptive correction procedures, and enables largely automated data processing across sites.« less

  3. Dielectric spectroscopy of SiO2, ZnO - nanoparticle loaded epoxy resin in the frequency range of 20 Hz to 2 MHz

    NASA Astrophysics Data System (ADS)

    Thakor, Sanketsinh; Rana, V. A.; Vankar, H. P.

    2017-05-01

    In present work, Bisphenol A-(epichlorhydrin); epoxy resin with hardener N(3-dimethylaminopropyl)-1,3-propylenediamine were used to determine the dielectric properties. Sample of the neat epoxy resin and nanoparticle loaded epoxy resin in the form of disc were prepared of different weight fraction. SiO2 and ZnO nanoparticles were taken as filler in the epoxy resin. Complex permittivity of the prepared samples was measured in the frequency range of 20 Hz to 2 MHz using precision LCR meter at room temperature. The charismatic change in dielectric behavior based on type and concentration of nanoparticle are discussed in detail.

  4. Subsurface Ice Detection via Low Frequency Surface Electromagnetic Method

    NASA Astrophysics Data System (ADS)

    Stillman, D. E.; Grimm, R. E.; Mcginnis, R. N.

    2014-12-01

    The geophysical detection of ice in the Cryosphere is typically conducted by measuring the absence of water. These interpretations can become non-unique in dry soils or in clay- and silt-rich soils that contain significant quantities of unfrozen water. Extensive laboratory measurements of electrical properties were made on permafrost samples as a function of frequency, temperature, and water content. These laboratory measurements show that the amount of ice can be uniquely obtained by measuring a frequency dependence of the electrical properties over a large frequency range (20 kHz - 10 Hz). In addition, the electrical properties of permafrost are temperature dependent, which can allow for an estimate of subsurface temperature. In order to test this approach in the field, we performed field surveys at four locations in Alaska. We used three low frequency electromagnetic methods: Spectral Induced Polarization (SIP: 20 kHz - 10 Hz), Capacively Coupled Resistivity (CCR: OhmMapper - 16.5 kHz), and DC Resistivity (Syscal ~ 8 Hz). At the Cold Regions Research and Engineering Laboratory permafrost tunnel near Fox, AK, we used SIP to measure the average ice concentration of 80 v% and determined the temperature to be -3±1°C by matching survey results to lab data. SIP data acquisition is very slow; therefore, at three sites near Tok, AK, we used CCR to perform reconnaissance of the area. Then SIP and DC resistivity were performed at anomalous areas. The three survey types give very similar absolute resistivity values. We found that while SIP gives the most quantitative results, the frequency dependence from the CCR and DC resistivity surveys is all that are needed to determine ice content in permafrost.

  5. Real-time digital filtering, event triggering, and tomographic reconstruction of JET soft x-ray data (abstract)

    NASA Astrophysics Data System (ADS)

    Edwards, A. W.; Blackler, K.; Gill, R. D.; van der Goot, E.; Holm, J.

    1990-10-01

    Based upon the experience gained with the present soft x-ray data acquisition system, new techniques are being developed which make extensive use of digital signal processors (DSPs). Digital filters make 13 further frequencies available in real time from the input sampling frequency of 200 kHz. In parallel, various algorithms running on further DSPs generate triggers in response to a range of events in the plasma. The sawtooth crash can be detected, for example, with a delay of only 50 μs from the onset of the collapse. The trigger processor interacts with the digital filter boards to ensure data of the appropriate frequency is recorded throughout a plasma discharge. An independent link is used to pass 780 and 24 Hz filtered data to a network of transputers. A full tomographic inversion and display of the 24 Hz data is carried out in real time using this 15 transputer array. The 780 Hz data are stored for immediate detailed playback following the pulse. Such a system could considerably improve the quality of present plasma diagnostic data which is, in general, sampled at one fixed frequency throughout a discharge. Further, it should provide valuable information towards designing diagnostic data acquisition systems for future long pulse operation machines when a high degree of real-time processing will be required, while retaining the ability to detect, record, and analyze events of interest within such long plasma discharges.

  6. Conductivity measurements on CdCl2 doped PVA solid polymeric electrolyte for battery application

    NASA Astrophysics Data System (ADS)

    Baraker, Basavarajeshwari M.; Lobo, Blaise

    2018-04-01

    Ionic conductivity of pure polyvinyl alcohol (PVA) and 6.3 wt% of CdCl2 doped PVA solid polymeric electrolyte have been studied using DC and AC electrical measurements. From DC electrical results, the determination transference number confirmed that ions are the dominant charge carriers in CdCl2 doped PVA. Interestingly, the ion transference number (ti) for 6.3 wt% CdCl2 doped sample is significantly more (0.993), when compared to that of pure PVA (for which, ti is 0.988). Temperature dependent dielectric studies showed interesting results at different frequencies: 120 Hz, 500 Hz, 1 kHz, 5 kHz, 10 kHz and 100 kHz.

  7. The Upgraded Kharkiv V. N. Karazin National University Radiophysical Observatory

    NASA Astrophysics Data System (ADS)

    Chernogor, L. F.; Garmash, K. P.; Podnos, V. A.; Rozumenko, V. T.; Tsymbal, A. M.; Tyrnov, O. F.

    2012-11-01

    The Kharkiv V. N. Karazin National University Radiophysical Observatory clustered instruments are located at two sites, Gaidary (49°37'51'' N; 36°19'40.1'' E) and Grakovo (49°38'49'' N; 36°56'07'' E), where sample clock synchronization is accomplished by using GPS receivers. It is a powerful tool for identifying hidden linkages between different altitudes from the D region to GPS orbits. The findings from some experimental studies are illustrated. The MF-HF radar (Gaidary) simultaneously employs the differential absorption, spaced antenna, and the ionosonde techniques. HF Doppler sounding system comprises an HF Doppler radar at vertical incidence at Gaidary (it simultaneously makes soundings at three frequencies) and a passive radar system at Grakovo (it simultaneously observes four frequencies in the 30 kHz - 3 MHz band and eight frequencies in the 1 - 31 MHz band with a velocity resolution of a few m s-1 in most cases). Low-Earth orbit Cicada/Cicada-M and GPS/GLONASS navigation satellite TEC observations are made at Gaidary and Kharkiv City. Since 2001, the fluxgate magnetometer (Grakovo) has acquired measurements in the south-north (H component) and west-east (D) directions at half-second intervals in the 0.001 - 1Hz frequency band within which the internal noise varies from 0.5 pT at f = 1 Hz to 50 pT at f = 0.01Hz. The three-axis saturable-core magnetometer (Gaidary) acquires measurements in the two frequency bands, 0.01 - 0.1 Hz and 0.1 - 5 Hz, where the internal noise level does not exceed 0.075 nT.

  8. Investigation of a Bio-Inspired Liner Concept

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle

    2017-01-01

    Four samples of natural reeds, Phragmites australis, were tested in the NASA Langley and Glenn Normal Incidence Impedance Tubes in order to experimentally determine the acoustic absorption coefficients as a function of frequency from 400 to 3000 Hz. Six samples that mimicked the geometry of the assemblies of natural reeds were also designed and additively manufactured from ASA thermoplastic and tested. Results indicate that structures can be manufactured of synthetic materials that mimic the geometry and the low frequency acoustic absorption of natural reeds. This accomplishment demonstrates that a new class of structures can now be considered for a wide range of industrial products that need thin, lightweight, broadband acoustic absorption effective at frequencies below 1000 Hz. Aircraft engine acoustic liners and aircraft cabin acoustic liners, in particular, are two aviation applications that might benefit from further development of this concept.

  9. Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation.

    PubMed

    Haemmerich, Dieter; Schutt, David J; Wright, Andrew W; Webster, John G; Mahvi, David M

    2009-05-01

    We measured the ex vivo electrical conductivity of eight human metastatic liver tumours and six normal liver tissue samples from six patients using the four electrode method over the frequency range 10 Hz to 1 MHz. In addition, in a single patient we measured the electrical conductivity before and after the thermal ablation of normal and tumour tissue. The average conductivity of tumour tissue was significantly higher than normal tissue over the entire frequency range (from 4.11 versus 0.75 mS cm(-1) at 10 Hz, to 5.33 versus 2.88 mS cm(-1) at 1 MHz). We found no significant correlation between tumour size and measured electrical conductivity. While before ablation tumour tissue had considerably higher conductivity than normal tissue, the two had similar conductivity throughout the frequency range after ablation. Tumour tissue conductivity changed by +25% and -7% at 10 Hz and 1 MHz after ablation (0.23-0.29 at 10 Hz, and 0.43-0.40 at 1 MHz), while normal tissue conductivity increased by +270% and +10% at 10 Hz and 1 MHz (0.09-0.32 at 10 Hz and 0.37-0.41 at 1 MHz). These data can potentially be used to differentiate tumour from normal tissue diagnostically.

  10. Estimation of the center frequency of the highest modulation filter.

    PubMed

    Moore, Brian C J; Füllgrabe, Christian; Sek, Aleksander

    2009-02-01

    For high-frequency sinusoidal carriers, the threshold for detecting sinusoidal amplitude modulation increases when the signal modulation frequency increases above about 120 Hz. Using the concept of a modulation filter bank, this effect might be explained by (1) a decreasing sensitivity or greater internal noise for modulation filters with center frequencies above 120 Hz; and (2) a limited span of center frequencies of the modulation filters, the top filter being tuned to about 120 Hz. The second possibility was tested by measuring modulation masking in forward masking using an 8 kHz sinusoidal carrier. The signal modulation frequency was 80, 120, or 180 Hz and the masker modulation frequencies covered a range above and below each signal frequency. Four highly trained listeners were tested. For the 80-Hz signal, the signal threshold was usually maximal when the masker frequency equaled the signal frequency. For the 180-Hz signal, the signal threshold was maximal when the masker frequency was below the signal frequency. For the 120-Hz signal, two listeners showed the former pattern, and two showed the latter pattern. The results support the idea that the highest modulation filter has a center frequency in the range 100-120 Hz.

  11. The Polar Plasma Wave Instrument

    NASA Technical Reports Server (NTRS)

    Gurnett, D. A.; Persoon, A. M.; Randall, R. F.; Odem, D. L.; Remington, S. L.; Averkamp, T. F.; Debower, M. M.; Hospodarsky, G. B.; Huff, R. L.; Kirchner, D. L.

    1995-01-01

    The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s(exp -1).

  12. High-resolution imaging of magnetic fields using scanning superconducting quantum interference device (SQUID) microscopy

    NASA Astrophysics Data System (ADS)

    Fong de Los Santos, Luis E.

    Development of a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with sub-millimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensor is mounted in the tip of a sapphire rod and thermally anchored to the cryostat helium reservoir. A 25 mum sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows adjusting the sample-to-sensor spacing from the top of the Dewar. I have achieved a sensor-to-sample spacing of 100 mum, which could be maintained for periods of up to 4 weeks. Different SQUID sensor configurations are necessary to achieve the best combination of spatial resolution and field sensitivity for a given magnetic source. For imaging thin sections of geological samples, I used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80 mum, and achieved a field sensitivity of 1.5 pT/Hz1/2 and a magnetic moment sensitivity of 5.4 x 10-18 Am2/Hz1/2 at a sensor-to-sample spacing of 100 mum in the white noise region for frequencies above 100 Hz. Imaging action currents in cardiac tissue requires higher field sensitivity, which can only be achieved by compromising spatial resolution. I developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250 mum to 1 mm, and achieved sensitivities of 480 - 180 fT/Hz1/2 in the white noise region for frequencies above 100 Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of geological samples.

  13. A single-frequency Ho:YLF pulsed laser with frequency stability better than 500 kHz

    NASA Astrophysics Data System (ADS)

    Kucirek, P.; Meissner, A.; Nyga, S.; Mertin, J.; Höfer, M.; Hoffmann, H.-D.

    2017-03-01

    The spectral stability of a previously reported Ho:YLF single frequency pulsed laser oscillator emitting at 2051 nm is drastically improved by utilizing a narrow linewidth Optically Pumped Semiconductor Laser (OPSL) as a seed for the oscillator. The oscillator is pumped by a dedicated gain-switched Tm:YLF laser at 1890 nm. The ramp-and-fire method is employed for generating single frequency emission. The heterodyne technique is used to analyze the spectral properties. The laser is designed to meet a part of the specifications for future airborne or space borne LIDAR detection of CO2. Seeding with a DFB diode and with an OPSL are compared. With OPSL seeding an Allan deviation of the centroid of the spectral distribution of 38 kHz and 517 kHz over 10 seconds and 60 milliseconds of sampling time for single pulses is achieved. The spectral width is approximately 30 MHz. The oscillator emits 2 mJ pulse energy with 50 Hz pulse repetition frequency (PRF) and 20 ns pulse duration. The optical to optical efficiency of the Ho:YLF oscillator is 10 % and the beam quality is diffraction limited. To our knowledge this is the best spectral stability demonstrated to date for a Ho:YLF laser with millijoule pulse energy and nanosecond pulse duration.

  14. Mechanical properties of porcine brain tissue in vivo and ex vivo estimated by MR elastography.

    PubMed

    Guertler, Charlotte A; Okamoto, Ruth J; Schmidt, John L; Badachhape, Andrew A; Johnson, Curtis L; Bayly, Philip V

    2018-03-01

    The mechanical properties of brain tissue in vivo determine the response of the brain to rapid skull acceleration. These properties are thus of great interest to the developers of mathematical models of traumatic brain injury (TBI) or neurosurgical simulations. Animal models provide valuable insight that can improve TBI modeling. In this study we compare estimates of mechanical properties of the Yucatan mini-pig brain in vivo and ex vivo using magnetic resonance elastography (MRE) at multiple frequencies. MRE allows estimations of properties in soft tissue, either in vivo or ex vivo, by imaging harmonic shear wave propagation. Most direct measurements of brain mechanical properties have been performed using samples of brain tissue ex vivo. It has been observed that direct estimates of brain mechanical properties depend on the frequency and amplitude of loading, as well as the time post-mortem and condition of the sample. Using MRE in the same animals at overlapping frequencies, we observe that porcine brain tissue in vivo appears stiffer than porcine brain tissue samples ex vivo at frequencies of 100 Hz and 125 Hz, but measurements show closer agreement at lower frequencies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. VizieR Online Data Catalog: HCOO13CH3 rotational spectrum

    NASA Astrophysics Data System (ADS)

    Haykal, I.; Carvajal, M.; Tercero, B.; Kleiner, I.; Lopez, A.; Cernicharo, J.; Motiyenko, R. A.; Huet, T. R.; Guillemin, J. C.; Margules, L.

    2014-08-01

    The details about synthesis and identification by NMR spectroscopy were described in Carvajal et al. (2009, Cat. J/A+A/500/1109). The millimeter- and submillimeter-wave spectra were recorded using the Lille spectrometer that is based on solid-state sources. The sample pressure was in the range 20-30x10-6 bars. Spectra were recorded at room temperature (T=294K) in the 150-210, 225-315, 400-500, 500-630, and 780-940GHz regions with frequency steps of 30, 36, 48, 54, and 76kHz and an acquisition time of 35ms per point. The absolute accuracy of the line-centre frequency is estimated to be better than 30kHz (50kHz above 700GHz) for isolated lines and can be as low as 100kHz (150kHz above 700GHz) for blended or very weak lines. See section 2.2. The IRAM spectra will be published on the IRAM website: http://www.iram-institute.org/ (1 data file).

  16. Quasiperiodic oscillations of the sub-mHz band in near-sun plasma according to the coherent radio occultation data

    NASA Astrophysics Data System (ADS)

    Efimov, A. I.; Lukanina, L. A.; Chashei, I. V.; Kolomiets, S. F.; Bird, M. K.; Pätzold, M.

    2018-01-01

    In 2013 and 2015, investigations of the internal solar wind were carried out using the method of two-frequency radio sounding by signals from the Mars Express European spacecraft. The values of the S- and X-bands' frequency and the differential frequency were registered with a sampling rate of 1s at the American and European networks of ground-based tracking stations. The spatial distribution of the frequency fluctuation's level has been studied. It has been shown that the intensity of frequency fluctuation considerably decreases at high heliolatitudes. In some radio sounding sessions, quasiperiodic oscillations of sub-mHz band have been observed in the temporal spectra of frequency fluctuations; they are supposed to be associated with the density inhomogeneities, the sizes of which are close to the turbulence outer scale.

  17. Dielectric properties of binary mixtures of methyl iso butyl ketone and amino silicone oil

    NASA Astrophysics Data System (ADS)

    Shah, K. N.; Rana, V. A.; Trivedi, C. M.; Vankar, H. P.

    2017-05-01

    Dielectric permittivity ɛ*(ω) = ɛ' - jɛ″ of the binary mixtures of the methyl iso butyl ketone and amino silicone oil in the frequency range 100 Hz to 2 MHz were measured using precision LCR meter at 305.15 K. Relative complex permittivity spectra in the frequency range 100 Hz to 2 MHz, of the mixture solutions of varying concentrations is reported. Determined values of the permittivity at optical frequency of all the samples are also reported. The dielectric parameters are used to gain information about the effect of concentration variation of components of the mixtures on the dielectric properties. It also provides the information about electrode polarization phenomena taking place under the low frequency A.C. electric field.

  18. 47 CFR 87.303 - Frequencies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...

  19. 47 CFR 87.303 - Frequencies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...

  20. 47 CFR 87.303 - Frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...

  1. 47 CFR 87.303 - Frequencies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... only. (f) Frequency assignments for Flight Test VHF Stations may be based on either 8.33 kHz or 25 kHz spacing. Assignable frequencies include the interstitial frequencies 8.33 kHz from the VHF frequencies listed in paragraphs (a) and (b) of this section. Each 8.33 kHz interstitial frequency is subject to the...

  2. Source parameter estimates of echolocation clicks from wild pygmy killer whales (Feresa attenuata) (L)

    NASA Astrophysics Data System (ADS)

    Madsen, P. T.; Kerr, I.; Payne, R.

    2004-10-01

    Pods of the little known pygmy killer whale (Feresa attenuata) in the northern Indian Ocean were recorded with a vertical hydrophone array connected to a digital recorder sampling at 320 kHz. Recorded clicks were directional, short (25 μs) transients with estimated source levels between 197 and 223 dB re. 1 μPa (pp). Spectra of clicks recorded close to or on the acoustic axis were bimodal with peak frequencies between 45 and 117 kHz, and with centroid frequencies between 70 and 85 kHz. The clicks share characteristics of echolocation clicks from similar sized, whistling delphinids, and have properties suited for the detection and classification of prey targeted by this odontocete. .

  3. Dielectric studies on PEG-LTMS based polymer composites

    NASA Astrophysics Data System (ADS)

    Patil, Ravikumar V.; Praveen, D.; Damle, R.

    2018-02-01

    PEG LTMS based polymer composites were prepared and studied for dielectric constant variation with frequency and temperature as a potential candidate with better dielectric properties. Solution cast technique is used for the preparation of polymer composite with five different compositions. Samples show variation in dielectric constant with frequency and temperature. Dielectric constant is large at low frequencies and higher temperatures. Samples with larger space charges have shown larger dielectric constant. The highest dielectric constant observed was about 29244 for PEG25LTMS sample at 100Hz and 312 K.

  4. Frequency-Unspecific Effects of θ-tACS Related to a Visuospatial Working Memory Task

    PubMed Central

    Kleinert, Maria-Lisa; Szymanski, Caroline; Müller, Viktor

    2017-01-01

    Working memory (WM) is crucial for intelligent cognitive functioning, and synchronization phenomena in the fronto-parietal network have been suggested as an underlying neural mechanism. In an attempt to provide causal evidence for this assumption, we applied transcranial alternating current stimulation (tACS) at theta frequency over fronto-parietal sites during a visuospatial match-to-sample (MtS) task. Depending on the stimulation protocol, i.e., in-phase, anti-phase or sham, we anticipated a differential impact of tACS on behavioral WM performance as well as on the EEG (electroencephalography) during resting state before and after stimulation. We hypothesized that in-phase tACS of the fronto-parietal theta network (stimulation frequency: 5 Hz; intensity: 1 mA peak-to-peak) would result in performance enhancement, whereas anti-phase tACS would cause performance impairment. Eighteen participants (nine female) received in-phase, anti-phase, and sham stimulation in balanced order. While being stimulated, subjects performed the MtS task, which varied in executive demand (two levels: low and high). EEG analysis of power peaks within the delta (0.5–4 Hz), theta (4–8 Hz), alpha (8–12 Hz), and beta (12–30 Hz) frequency bands was carried out. No significant differences were observed between in-phase and anti-phase stimulation regarding both behavioral and EEG measurements. Yet, with regard to the alpha frequency band, we observed a statistically significant drop of peak power from pre to post in the sham condition, whereas alpha power remained on a similar level in the actively stimulated conditions. Our results indicate a frequency-unspecific modulation of neuronal oscillations by tACS. However, the closer participants’ individual theta peak frequencies were to the stimulation frequency of 5 Hz after anti-phase tACS, the faster they responded in the MtS task. This effect did not reach statistical significance during in-phase tACS and was not present during sham. A lack of statistically significant behavioral results in the MtS task and frequency-unspecific effects on the electrophysiological level question the effectiveness of tACS in modulating cortical oscillations in a frequency-specific manner. PMID:28747881

  5. Effect of electrical stunning frequency on meat quality, plasma parameters, and protein solubility of broilers.

    PubMed

    Huang, J C; Yang, J; Zhang, B H; Huang, M; Chen, K J; Xu, X L; Zhou, G H

    2017-08-01

    This study was designed to compare the effects of different stunning frequencies of pulsed direct current on meat quality of broilers. This was achieved by investigating plasma parameters, blood loss, carcass damage, meat water-holding capacity, meat color, meat shear value, muscle pH, and protein solubility. A total of 400 broilers was divided into 5 treatment groups and stunned with 500, 600, 700, 800, and 900 Hz at 15 V for 10 seconds. Blood samples were collected immediately after cutting the neck. Pectoralis major muscles were removed from the carcass after chilling and placed in ice. Breast muscle pH and meat color were determined at both 2 and 24 h postmortem. Drip loss, cooking loss, pressing loss, and cooked breast meat-shear values were determined at 24 h postmortem. Treatment at 500 and 900 Hz significantly increased (P < 0.05) blood plasma corticosterone and lactate concentrations compared with the 700 Hz group. The wing damage of carcasses was significantly serious in the 500, 800, and 900 Hz groups. The Pectoralis minor damage of carcesses in the 700 Hz group was significantly lower (P < 0.05) compared to the other stunning groups. The pH at 2 h postmortem in the 500 and 900 Hz groups was significantly lower (P < 0.05) than in other groups. However, the final pH and meat color were not affected by stunning frequency. In the 500 and 900 Hz groups, the protein solubility and shear force values were significantly lower (P < 0.05) and drip loss was significantly higher (P < 0.05) than in the 700 Hz group. This study indicates that the waveform of the pulsed direct current is acceptable for stunning broilers at a stunning frequency of 700 Hz. © 2017 Poultry Science Association Inc.

  6. Wire Arc Additive Manufacturing of AZ31 Magnesium Alloy: Grain Refinement by Adjusting Pulse Frequency

    PubMed Central

    Guo, Jing; Zhou, Yong; Liu, Changmeng; Wu, Qianru; Chen, Xianping; Lu, Jiping

    2016-01-01

    Wire arc additive manufacturing (WAAM) offers a potential approach to fabricate large-scale magnesium alloy components with low cost and high efficiency, although this topic is yet to be reported in literature. In this study, WAAM is preliminarily applied to fabricate AZ31 magnesium. Fully dense AZ31 magnesium alloy components are successfully obtained. Meanwhile, to refine grains and obtain good mechanical properties, the effects of pulse frequency (1, 2, 5, 10, 100, and 500 Hz) on the macrostructure, microstructure and tensile properties are investigated. The results indicate that pulse frequency can result in the change of weld pool oscillations and cooling rate. This further leads to the change of the grain size, grain shape, as well as the tensile properties. Meanwhile, due to the resonance of the weld pool at 5 Hz and 10 Hz, the samples have poor geometry accuracy but contain finer equiaxed grains (21 μm) and exhibit higher ultimate tensile strength (260 MPa) and yield strength (102 MPa), which are similar to those of the forged AZ31 alloy. Moreover, the elongation of all samples is above 23%. PMID:28773944

  7. Breaking through the bandwidth barrier in distributed fiber vibration sensing by sub-Nyquist randomized sampling

    NASA Astrophysics Data System (ADS)

    Zhang, Jingdong; Zhu, Tao; Zheng, Hua; Kuang, Yang; Liu, Min; Huang, Wei

    2017-04-01

    The round trip time of the light pulse limits the maximum detectable frequency response range of vibration in phase-sensitive optical time domain reflectometry (φ-OTDR). We propose a method to break the frequency response range restriction of φ-OTDR system by modulating the light pulse interval randomly which enables a random sampling for every vibration point in a long sensing fiber. This sub-Nyquist randomized sampling method is suits for detecting sparse-wideband- frequency vibration signals. Up to MHz resonance vibration signal with over dozens of frequency components and 1.153MHz single frequency vibration signal are clearly identified for a sensing range of 9.6km with 10kHz maximum sampling rate.

  8. Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou Jun; Sebastian, Evelyn; Mangona, Victor

    2013-02-15

    Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For themore » static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.« less

  9. High frequency oscillations (80–500 Hz) in the preictal period in patients with focal seizures

    PubMed Central

    Jacobs, Julia; Zelmann, Rina; Jirsch, Jeffrey; Chander, Rahul; Châtillon, Claude-Édouard; Dubeau, François; Gotman, Jean

    2013-01-01

    Summary Purpose Intracranial depth macroelectrode recordings from patients with focal seizures demonstrate interictal and ictal high frequency oscillations (HFOs, 80–500 Hz). These HFOs are more frequent in the seizure-onset zone (SOZ) and reported to be linked to seizure genesis. We evaluated whether HFO activity changes in a systematic way during the preictal period. Methods Fifteen minutes of preictal intracranial electroencephalography (EEG) recordings were evaluated in seven consecutive patients with well-defined SOZ. EEG was filtered at 500 Hz and sampled at 2,000 Hz. Ripples (80–250 Hz) and fast ripples (250–500 Hz) were visually marked, and spectral analysis was performed in seizure-onset as well as nonseizure-onset channels. Linear regressions fitted to the power trends corresponding to intervals of 1, 5, and 15 min before the seizure onset was calculated. Results Total rates of HFOs were significantly higher in the SOZ than outside. Preictal increases and decreases in HFO rates and band power could be detected in all patients, and they were not limited to the SOZs. These measures were very variable, and nosystematic trends were observed when comparing patients or seizures in the same patient. Discussion High frequencies in the range of 80–500 Hz are present during the preictal period and are more prominent in the SOZ. They do not change in a systematic way before seizure onset for the horizons we tested. The 80–500 Hz band may be used for the localization of seizure-onset areas but may be more difficult to use for seizure prediction purposes. PMID:19400871

  10. Evidence from Quasi-Periodic Oscillations for a Millisecond Pulsar in the Low Mass X-Ray Binary 4U 0614+091

    NASA Technical Reports Server (NTRS)

    Ford, E.; Kaaret, P.; Tavani, M.; Barret, D.; Bloser, P.; Grindlay, J.; Harmon, B. A.; Paciesas, W. S.; Zhang, S. N.

    1997-01-01

    We have detected quasi-periodic oscillations (QPOs) near 1 kHz from the low mass X-ray binary 4U 0614+091 in observations with RXTE. The observations span several months and sample the source over a large range of X-ray luminosity. In every interval QPOs are present above 400 Hz with fractional RMS amplitudes from 3 to 12% over the full PCA band. At high count rates, two high frequency QPOs are detected simultaneously. The difference of their frequency centroids is consistent with a constant value of 323 Hz in all observations. During one interval a third signal is detected at 328 +/- 2 Hz. This suggests the system has a stable 'clock' which is most likely the neutron star with spin period 3.1 msec. Thus, our observations of 4U 0614+091 and those of 4U 1728-34 provide the first evidence for millisecond pulsars within low-mass X-ray binary systems and reveal the 'missing-link' between millisecond radiopulsars and the late stages of binary evolution in low mass X-ray binaries. The constant difference of the high frequency QPOs sug,,ests a beat-frequency interpretation. In this model, the high frequency QPO is associated with the Keplerian frequency of the inner accretion disk and the lower frequency QPO is a 'beat' between the differential rotation frequency of the inner disk and the spinning neutron star. Assuming the high frequency QPO is a Keplerian orbital frequency for the accretion disk, we find a maximum mass of 1.9 solar mass and a maximum radius of 17 km for the neutron star.

  11. Intravenous cannulation of adolescents does not affect the modulation of autonomic tone assessed by heart rate and blood pressure variability.

    PubMed

    Stewart, J M

    2000-02-01

    Invasive arterial monitoring alters autonomic tone. The effects of intravenous (i.v.) insertion are less clear. The author assessed the effects of i.v. insertion on autonomic activity in patients aged 11 to 19 years prior to head-up tilt by measuring heart rate, blood pressure, heart rate variability, blood pressure variability, and baroreceptor gain before and after i.v. insertion with continuous electrocardiography and arterial tonometry in patients with orthostatic tachycardia syndrome (OTS, N = 21), in patients who experienced simple fainting (N = 14), and in normal control subjects (N = 6). Five-minute samples were collected after 30 minutes supine. Fifteen minutes after i.v. insertion, data were collected again. These 5-minute samples were also collected in a separate control population without i.v. insertion after 30 minutes supine and again 30 minutes later. This population included 12 patients with OTS, 13 patients who experienced simple fainting, and 6 normal control subjects. Heart rate variability included the mean RR, the standard deviation of the RR interval (SDNN), and the root mean square of successive RR differences (RMSSD). Autoregressive spectral modeling was used. Low-frequency power (LFP, 0.04-0.15 Hz), high-frequency power (HFP, 0.15-0.40 Hz), and total power (TP, 0.01-0.40 Hz) were compared. Blood pressure variability included standard deviation of systolic blood pressure, LFP, and HFP. Baroreceptor gain at low frequency and high frequency was calculated from cross-spectral transfer function magnitudes when coherence was greater than 0.5. In patients with OTS, RR (790 +/- 50 msec), SDNN (54 +/- 6 msec), RMSSD (55 +/- 5 msec), LFP (422 +/- 200 ms2/Hz), HFP (846 +/- 400 ms2/Hz), and TP (1550 +/- 320 ms2/Hz) were less than in patients who experienced simple fainting (RR, 940 +/- 50 msec; SDNN, 84 +/- 10 msec; RMSSD, 91 +/- 7 msec; LFP, 880 +/- 342 ms2/Hz; HFP, 1720 +/- 210 ms2/Hz; and TP, 3228 +/- 490 ms2/Hz) or normal control subjects (RR, 920 +/- 30 msec; SDNN, 110 +/- 29 msec; RMSSD, 120 +/- 16 msec; LFP, 1600 +/- 331 ms2/Hz; HFP, 2700 +/- 526 ms2/Hz; and TP, 5400 +/- 1017 ms2/Hz). Blood pressure and blood pressure variability were not different in any group. Standard deviation, LFP, and HFP were, respectively, 5.24 +/- 0.8 mm Hg, 1.2 +/- 0.2, and 1.5 +/- 0.3 for patients with OTS; 4.6 +/- 0.4 mm Hg, 1.2 +/- 0.2, and 1.4 +/- 0.3 for patients who experienced simple fainting; and 5.55 +/- 1.0 mm Hg, 1.4 +/- 0.2, and 1.6 +/- 0.3 for normal control subjects. Baroreceptor gain at low frequency and high frequency in patients with OTS (16 +/- 4 msec/mm Hg, 17 +/- 5) was comparable to that in patients who experienced simple fainting (33 +/- 4, 32 +/- 3) and that in normal control subjects (31 +/- 8, 37 +/- 9). Heart rate variability differed between patients with OTS and patients who experienced simple fainting or normal control subjects, and blood pressure and blood pressure variability were not different, but no parameter changed after i.v. insertion. There were no differences from the groups that did not receive i.v. insertions. Data suggest, at most, a limited effect of i.v. insertion on autonomic function in adolescents.

  12. Dielectric study of aqueous solutions of sodium dodecyl sulfate in the frequency span 20 Hz to 2 MHz

    NASA Astrophysics Data System (ADS)

    Kadve, A. M.; Vankar, H. P.; Rana, V. A.

    2017-05-01

    Dielectric measurements were carried out for aqueous solutions of Sodium Dodecyl Sulfate (SDS) in the frequency span of 20 Hz to 2 MHz at 300.15 K temperature using precision LCR meter. Also the refractive indices were measured for the solutions at 300.15 K temperature using Abbe's refractometer. The measurements were done for ten different concentrations of SDS in distilled water. Determined values of complex permittivity as a function of frequency were used to evaluate other parameters like loss tangent and electric modulus for the liquid samples. The permittivity at optical frequency were also calculated from the measured refractive indices for the aqueous solutions. The effect of concentration variation of SDS in the aqueous solutions on the determined parameters is discussed.

  13. Splitting attention reduces temporal resolution from 7 Hz for tracking one object to <3 Hz when tracking three.

    PubMed

    Holcombe, Alex O; Chen, Wei-Ying

    2013-01-09

    Overall performance when tracking moving targets is known to be poorer for larger numbers of targets, but the specific effect on tracking's temporal resolution has never been investigated. We document a broad range of display parameters for which visual tracking is limited by temporal frequency (the interval between when a target is at each location and a distracter moves in and replaces it) rather than by object speed. We tested tracking of one, two, and three moving targets while the eyes remained fixed. Variation of the number of distracters and their speed revealed both speed limits and temporal frequency limits on tracking. The temporal frequency limit fell from 7 Hz with one target to 4 Hz with two targets and 2.6 Hz with three targets. The large size of this performance decrease implies that in the two-target condition participants would have done better by tracking only one of the two targets and ignoring the other. These effects are predicted by serial models involving a single tracking focus that must switch among the targets, sampling the position of only one target at a time. If parallel processing theories are to explain why dividing the tracking resource reduces temporal resolution so markedly, supplemental assumptions will be required.

  14. Modulatory frequency of lasers in connection to laser beam therapeutic effect

    NASA Astrophysics Data System (ADS)

    Kucerova, Hana; Bartova, Jirina; Himmlova, Lucia; Dostalova, Tatjana; Mazanek, Jiri

    1998-04-01

    The subject of this work follows changes of the sIgA and albumin levels in the saliva of 48 patients treated after the extraction of their lower molars with either diode or He-Ne biostimulatory laser, using different modulatory frequencies (5 Hz, 292 Hz, 9000 Hz). The results were compared to the sIgA and albumin levels in the saliva of the control, i.e. not- treated group. For the tests radial immunodiffusion (RID) method was used (commercial RID kit of the Binding Site, Birmingham, Great Britain). Appropriately chosen laser beam modulatory frequency should influence the increase in the sIgA and albumin levels against the base level. In our study, this hypothesis was confirmed in the group treated with the frequency of 292 Hz and 9000 Hz (both diode GaAIAs, 670 nm, red, 20 mW, energy density 1.5 Jcm2) on albumin levels and 9000 Hz on sIgA levels. The changes of the levels of the watched markers versus the control group were at this frequencies (292 Hz and 9000 Hz) statistically significant. At the others used frequencies (5 Hz diode laser and 5 Hz He-Ne laser) the changes of the levels of the watched markers versus control group were statistically insignificant. The aim of this study was to contribute to the evaluation of specific modulatory frequencies (5 Hz, 292 Hz, 9000 Hz) for therapeutical use in a given pathological case of the oral cavity. We can conclude that using frequency 9000 Hz had best immunomodulatory effect.

  15. Plasma plume oscillations monitoring during laser welding of stainless steel by discrete wavelet transform application.

    PubMed

    Sibillano, Teresa; Ancona, Antonio; Rizzi, Domenico; Lupo, Valentina; Tricarico, Luigi; Lugarà, Pietro Mario

    2010-01-01

    The plasma optical radiation emitted during CO2 laser welding of stainless steel samples has been detected with a Si-PIN photodiode and analyzed under different process conditions. The discrete wavelet transform (DWT) has been used to decompose the optical signal into various discrete series of sequences over different frequency bands. The results show that changes of the process settings may yield different signal features in the range of frequencies between 200 Hz and 30 kHz. Potential applications of this method to monitor in real time the laser welding processes are also discussed.

  16. The influence of inertial sensor sampling frequency on the accuracy of measurement parameters in rearfoot running.

    PubMed

    Mitschke, Christian; Zaumseil, Falk; Milani, Thomas L

    2017-11-01

    Increasingly, inertial sensors are being used for running analyses. The aim of this study was to systematically investigate the influence of inertial sensor sampling frequencies (SF) on the accuracy of kinematic, spatio-temporal, and kinetic parameters. We hypothesized that running analyses at lower SF result in less signal information and therefore the inability to sufficiently interpret measurement data. Twenty-one subjects participated in this study. Rearfoot strikers ran on an indoor running track at a velocity of 3.5 ± 0.1 ms -1 . A uniaxial accelerometer was attached at the tibia and an inertial measurement unit was mounted at the heel of the right shoe. All sensors were synchronized at the start and data was measured with 1000 Hz (reference SF). Datasets were reduced to 500, 333, 250, 200, and 100 Hz in post-processing. The results of this study showed that a minimum SF of 500 Hz should be used to accurately measure kinetic parameters (e.g. peak heel acceleration). In contrast, stride length showed accurate results even at 333 Hz. 200 Hz were required to calculate parameters accurately for peak tibial acceleration, stride duration, and all kinematic measurements. The information from this study is necessary to correctly interpret measurement data of existing investigations and to plan future studies.

  17. A Novel Energy-Efficient Approach for Human Activity Recognition.

    PubMed

    Zheng, Lingxiang; Wu, Dihong; Ruan, Xiaoyang; Weng, Shaolin; Peng, Ao; Tang, Biyu; Lu, Hai; Shi, Haibin; Zheng, Huiru

    2017-09-08

    In this paper, we propose a novel energy-efficient approach for mobile activity recognition system (ARS) to detect human activities. The proposed energy-efficient ARS, using low sampling rates, can achieve high recognition accuracy and low energy consumption. A novel classifier that integrates hierarchical support vector machine and context-based classification (HSVMCC) is presented to achieve a high accuracy of activity recognition when the sampling rate is less than the activity frequency, i.e., the Nyquist sampling theorem is not satisfied. We tested the proposed energy-efficient approach with the data collected from 20 volunteers (14 males and six females) and the average recognition accuracy of around 96.0% was achieved. Results show that using a low sampling rate of 1Hz can save 17.3% and 59.6% of energy compared with the sampling rates of 5 Hz and 50 Hz. The proposed low sampling rate approach can greatly reduce the power consumption while maintaining high activity recognition accuracy. The composition of power consumption in online ARS is also investigated in this paper.

  18. Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors.

    PubMed

    Phinyomark, Angkoon; N Khushaba, Rami; Scheme, Erik

    2018-05-18

    Specialized myoelectric sensors have been used in prosthetics for decades, but, with recent advancements in wearable sensors, wireless communication and embedded technologies, wearable electromyographic (EMG) armbands are now commercially available for the general public. Due to physical, processing, and cost constraints, however, these armbands typically sample EMG signals at a lower frequency (e.g., 200 Hz for the Myo armband) than their clinical counterparts. It remains unclear whether existing EMG feature extraction methods, which largely evolved based on EMG signals sampled at 1000 Hz or above, are still effective for use with these emerging lower-bandwidth systems. In this study, the effects of sampling rate (low: 200 Hz vs. high: 1000 Hz) on the classification of hand and finger movements were evaluated for twenty-six different individual features and eight sets of multiple features using a variety of datasets comprised of both able-bodied and amputee subjects. The results show that, on average, classification accuracies drop significantly ( p.

  19. Speaking fundamental frequency and vowel formant frequencies: effects on perception of gender.

    PubMed

    Gelfer, Marylou Pausewang; Bennett, Quinn E

    2013-09-01

    The purpose of the present study was to investigate the contribution of vowel formant frequencies to gender identification in connected speech, the distinctiveness of vowel formants in males versus females, and how ambiguous speaking fundamental frequencies (SFFs) and vowel formants might affect perception of gender. Multivalent experimental. Speakers subjects (eight tall males, eight short females, and seven males and seven females of "middle" height) were recorded saying two carrier phrases to elicit the vowels /i/ and /α/ and a sentence. The gender/height groups were selected to (presumably) maximize formant differences between some groups (tall vs short) and minimize differences between others (middle height). Each subjects' samples were digitally altered to distinct SFFs (116, 145, 155, 165, and 207 Hz) to represent SFFs typical of average males, average females, and in an ambiguous range. Listeners judged the gender of each randomized altered speech sample. Results indicated that female speakers were perceived as female even with an SFF in the typical male range. For male speakers, gender perception was less accurate at SFFs of 165 Hz and higher. Although the ranges of vowel formants had considerable overlap between genders, significant differences in formant frequencies of males and females were seen. Vowel formants appeared to be important to perception of gender, especially for SFFs in the range of 145-165 Hz; however, formants may be a more salient cue in connected speech when compared with isolated vowels or syllables. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  20. High frequency analysis of cough sounds in pediatric patients with respiratory diseases.

    PubMed

    Kosasih, K; Abeyratne, U R; Swarnkar, V

    2012-01-01

    Cough is a common symptom in a range of respiratory diseases and is considered a natural defense mechanism of the body. Despite its critical importance in the diagnosis of illness, there are no golden methods to objectively assess cough. In a typical consultation session, a physician may briefly listen to the cough sounds using a stethoscope placed against the chest. The physician may also listen to spontaneous cough sounds via naked ears, as they naturally propagate through air. Cough sounds carry vital information on the state of the respiratory system but the field of cough analysis in clinical medicine is in its infancy. All existing cough analysis approaches are severely handicapped by the limitations of the human hearing range and simplified analysis techniques. In this paper, we address these problems, and explore the use of frequencies covering a range well beyond the human perception (up to 90 kHz) and use wavelet analysis to extract diagnostically important information from coughs. Our data set comes from a pediatric respiratory ward in Indonesia, from subjects diagnosed with asthma, pneumonia and rhinopharyngitis. We analyzed over 90 cough samples from 4 patients and explored if high frequencies carried useful information in separating these disease groups. Multiple regression analysis resulted in coefficients of determination (R(2)) of 77-82% at high frequencies (15 kHz-90 kHz) indicating that they carry useful information. When the high frequencies were combined with frequencies below 15kHz, the R(2) performance increased to 85-90%.

  1. High-resolution room-temperature sample scanning superconducting quantum interference device microscope configurable for geological and biomagnetic applications

    NASA Astrophysics Data System (ADS)

    Fong, L. E.; Holzer, J. R.; McBride, K. K.; Lima, E. A.; Baudenbacher, F.; Radparvar, M.

    2005-05-01

    We have developed a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with submillimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensors are mounted on the tip of a sapphire and thermally anchored to the helium reservoir. A 25μm sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows us to adjust the sample-to-sensor spacing from the top of the Dewar. We achieved a sensor-to-sample spacing of 100μm, which could be maintained for periods of up to four weeks. Different SQUID sensor designs are necessary to achieve the best combination of spatial resolution and field sensitivity for a given source configuration. For imaging thin sections of geological samples, we used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80μm, and achieved a field sensitivity of 1.5pT/Hz1/2 and a magnetic moment sensitivity of 5.4×10-18Am2/Hz1/2 at a sensor-to-sample spacing of 100μm in the white noise region for frequencies above 100Hz. Imaging action currents in cardiac tissue requires a higher field sensitivity, which can only be achieved by compromising spatial resolution. We developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250μm to 1mm, and achieved sensitivities of 480-180fT /Hz1/2 in the white noise region for frequencies above 100Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of geological samples.

  2. 47 CFR 95.629 - LPRS transmitter frequencies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...

  3. 47 CFR 95.629 - LPRS transmitter frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...

  4. 47 CFR 95.629 - LPRS transmitter frequencies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...

  5. 47 CFR 95.629 - LPRS transmitter frequencies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...

  6. 47 CFR 95.629 - LPRS transmitter frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... is 25 kHz. Channel No. Center frequency (MHz) 1 216.0125 2 216.0375 3 216.0625 4 216.0875 5 216.1125... extra band frequencies. The channel bandwidth is 50 kHz. Channel No. Center frequency (MHz) 41 216.025... frequencies. The channel bandwidth is 5 kHz and the authorized bandwidth is 4 kHz. Channel No. Center...

  7. A careful look at ECG sampling frequency and R-peak interpolation on short-term measures of heart rate variability.

    PubMed

    Ellis, Robert J; Zhu, Bilei; Koenig, Julian; Thayer, Julian F; Wang, Ye

    2015-09-01

    As the literature on heart rate variability (HRV) continues to burgeon, so too do the challenges faced with comparing results across studies conducted under different recording conditions and analysis options. Two important methodological considerations are (1) what sampling frequency (SF) to use when digitizing the electrocardiogram (ECG), and (2) whether to interpolate an ECG to enhance the accuracy of R-peak detection. Although specific recommendations have been offered on both points, the evidence used to support them can be seen to possess a number of methodological limitations. The present study takes a new and careful look at how SF influences 24 widely used time- and frequency-domain measures of HRV through the use of a Monte Carlo-based analysis of false positive rates (FPRs) associated with two-sample tests on independent sets of healthy subjects. HRV values from the first sample were calculated at 1000 Hz, and HRV values from the second sample were calculated at progressively lower SFs (and either with or without R-peak interpolation). When R-peak interpolation was applied prior to HRV calculation, FPRs for all HRV measures remained very close to 0.05 (i.e. the theoretically expected value), even when the second sample had an SF well below 100 Hz. Without R-peak interpolation, all HRV measures held their expected FPR down to 125 Hz (and far lower, in the case of some measures). These results provide concrete insights into the statistical validity of comparing datasets obtained at (potentially) very different SFs; comparisons which are particularly relevant for the domains of meta-analysis and mobile health.

  8. Dielectric characterization of TiO2, Al2O3 - Nanoparticle loaded epoxy resin

    NASA Astrophysics Data System (ADS)

    Thakor, S. G.; Rana, V. A.; Vankar, H. P.

    2018-05-01

    In present work, the dielectric properties of two different nanoparticle loaded Bisphenol A-epoxy resin were carried out at room temperature. Sample of the neat epoxy resin and nanoparticle loaded epoxy resin in the form of disc were prepared of different weight fraction (i.e 0.5 wt%,0.7 wt%,1 wt%,1.5 wt%,1.7 wt%,2 wt%). TiO2 and Al2O3 nanoparticles were taken as filler in the epoxy resin. Complex permittivity of the prepared samples was measured using Agilent E4980A precision LCR meter in frequency range of 103 Hz to 106 Hz. The dependency of dielectric behavior on type and concentration of nanoparticle in considered frequency range are discussed in detail.

  9. Conductivity and Dielectric Relaxation Properties of Annealed Cr-Substituted Ni-Ferrite Nanoparticles

    NASA Astrophysics Data System (ADS)

    El-Ghazzawy, E. H.

    2017-10-01

    Nanocrystalline NiCr x Fe2- x O4 spinel samples with x = 0.1 and 0.2 have been synthesized by coprecipitation method and annealed at 620°C and 1175°C for 4 h. Their electrical properties were investigated as functions of frequency in the range of 100 Hz to 100 kHz and temperature in the range of 308 K to 358 K. The dielectric constant ( ɛ^' } ) and dielectric loss factor ( {tan} δ ) appeared to decrease with increasing frequency, while the alternating-current (AC) conductivity ( σ^' } ) increased. These dielectric parameters increased with increasing temperature. On the other hand, impedance spectroscopy gave Cole-Cole plots with only one semicircular arc for all the samples, indicating that the grain-boundary contribution was dominant in the conduction mechanism.

  10. Depth Profiles in Maize ( Zea mays L.) Seeds Studied by Photoacoustic Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hernández-Aguilar, C.; Domínguez-Pacheco, A.; Cruz-Orea, A.; Zepeda-Bautista, R.

    2015-06-01

    Photoacoustic spectroscopy (PAS) has been used to analyze agricultural seeds and can be applied to the study of seed depth profiles of these complex samples composed of different structures. The sample depth profile can be obtained through the photoacoustic (PA) signal, amplitude, and phase at different light modulation frequencies. The PA signal phase is more sensitive to changes of thermal properties in layered samples than the PA signal amplitude. Hence, the PA signal phase can also be used to characterize layers at different depths. Thus, the objective of the present study was to obtain the optical absorption spectra of maize seeds ( Zea mays L.) by means of PAS at different light modulation frequencies (17 Hz, 30 Hz, and 50 Hz) and comparing these spectra with the ones obtained from the phase-resolved method in order to separate the optical absorption spectra of seed pericarp and endosperm. The results suggest the possibility of using the phase-resolved method to obtain optical absorption spectra of different seed structures, at different depths, without damaging the seed. Thus, PAS could be a nondestructive method for characterization of agricultural seeds and thus improve quality control in the food industry.

  11. Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

    NASA Technical Reports Server (NTRS)

    Dorrington, Adrian A.; Jones, Thomas W.; Danehy, Paul M.; Pappa, Richard S.

    2004-01-01

    A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

  12. Frequency dependence of p-mode frequency shifts induced by magnetic activity in Kepler solar-like stars

    NASA Astrophysics Data System (ADS)

    Salabert, D.; Régulo, C.; Pérez Hernández, F.; García, R. A.

    2018-04-01

    The variations of the frequencies of the low-degree acoustic oscillations in the Sun induced by magnetic activity show a dependence on radial order. The frequency shifts are observed to increase towards higher-order modes to reach a maximum of about 0.8 μHz over the 11-yr solar cycle. A comparable frequency dependence is also measured in two other main sequence solar-like stars, the F-star HD 49933, and the young 1 Gyr-old solar analog KIC 10644253, although with different amplitudes of the shifts of about 2 μHz and 0.5 μHz, respectively. Our objective here is to extend this analysis to stars with different masses, metallicities, and evolutionary stages. From an initial set of 87 Kepler solar-like oscillating stars with known individual p-mode frequencies, we identify five stars showing frequency shifts that can be considered reliable using selection criteria based on Monte Carlo simulations and on the photospheric magnetic activity proxy Sph. The frequency dependence of the frequency shifts of four of these stars could be measured for the l = 0 and l = 1 modes individually. Given the quality of the data, the results could indicate that a physical source of perturbation different from that in the Sun is dominating in this sample of solar-like stars.

  13. Onboard Processing on PWE OFA/WFC (Onboard Frequency Analyzer/Waveform Capture) aboard the ERG (ARASE) Satellite

    NASA Astrophysics Data System (ADS)

    Matsuda, S.; Kasahara, Y.; Kojima, H.; Kasaba, Y.; Yagitani, S.; Ozaki, M.; Imachi, T.; Ishisaka, K.; Kurita, S.; Ota, M.; Kumamoto, A.; Tsuchiya, F.; Yoshizumi, M.; Matsuoka, A.; Teramoto, M.; Shinohara, I.

    2017-12-01

    Exploration of energization and Radiation in Geospace (ERG) is a mission for understanding particle acceleration, loss mechanisms, and the dynamic evolution of space storms in the context of cross-energy and cross-regional coupling [Miyoshi et al., 2012]. The ERG (ARASE) satellite was launched on December 20, 2016, and successfully inserted into an orbit. The Plasma Wave Experiment (PWE) is one of the science instruments on board the ERG satellite to measure electric field and magnetic field in the inner magnetosphere. PWE consists of three sub-components, EFD (Electric Field Detector), OFA/WFC (Onboard Frequency Analyzer and Waveform Capture), and HFA (High Frequency Analyzer). Especially, OFA/WFC measures electric and magnetic field spectrum and waveform from a few Hz to 20 kHz. OFA/WFC processes signals detected by a couple of dipole wire-probe antenna (WPT) and tri-axis magnetic search coils (MSC) installed onboard the satellite. The PWE-OFA subsystem calculates and produces three kind of data; OFA-SPEC (power spectrum), OFA-MATRIX (spectrum matrix), and OFA-COMPLEX (complex spectrum). They are continuously processed 24 hours per day and all data are sent to the ground. OFA-MATRIX and OFA-COMPLEX are used for polarization analyses and direction finding of the plasma waves. The PWE-WFC subsystem measures raw (64 kHz sampled) and down-sampled (1 kHz sampled) burst waveform detected by the WPT and the MSC sensors. It activates by a command, automatic triggering, and scheduling. The initial check-out process of the PWE successfully completed, and initial data has been obtained. In this presentation, we introduce onboard processing technique on PWE OFA/WFC and its initial results.

  14. Ultralow-frequency-noise stabilization of a laser by locking to an optical fiber-delay line.

    PubMed

    Kéfélian, Fabien; Jiang, Haifeng; Lemonde, Pierre; Santarelli, Giorgio

    2009-04-01

    We report the frequency stabilization of an erbium-doped fiber distributed-feedback laser using an all-fiber-based Michelson interferometer of large arm imbalance. The interferometer uses a 1 km SMF-28 optical fiber spool and an acousto-optic modulator allowing heterodyne detection. The frequency-noise power spectral density is reduced by more than 40 dB for Fourier frequencies ranging from 1 Hz to 10 kHz, corresponding to a level well below 1 Hz2/Hz over the entire range; it reaches 10(-2) Hz2/Hz at 1 kHz. Between 40 Hz and 30 kHz, the frequency noise is shown to be comparable to the one obtained by Pound-Drever-Hall locking to a high-finesse Fabry-Perot cavity. Locking to a fiber delay line could consequently represent a reliable, simple, and compact alternative to cavity stabilization for short-term linewidth reduction.

  15. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    NASA Astrophysics Data System (ADS)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4.05 Hz), using shorter tubing and no dryer, that was also collocated at the site. Values of the N2O fluxes were similar between the two spectrometer systems (slope = 1.01, r2 = 0.96); CO2 fluxes as measured by the short-tubed eddy-covariance system and the two spectrometer systems correlated well (slope = 1.03, r2 = 0.998). The new lower-powered tunable diode laser absorption spectrometer configuration with the filterless intake and single-tube dryer showed promise for deployment in remote areas.

  16. Study of the Temporal Behavior of 4U 1728-34 as a Function of Its Position in the Color-Color Diagram

    NASA Astrophysics Data System (ADS)

    Di Salvo, T.; Méndez, M.; van der Klis, M.; Ford, E.; Robba, N. R.

    2001-01-01

    We study the timing properties of the bursting atoll source 4U 1728-34 as a function of its position in the X-ray color-color diagram. In the island part of the color-color diagram (corresponding to the hardest energy spectra), the power spectrum of 4U 1728-34 shows several features such as a band-limited noise component present up to a few tens of Hz, a low-frequency quasi-periodic oscillation (LFQPO) at frequencies between 20 and 40 Hz, a peaked noise component around 100 Hz, and one or two QPOs at kHz frequencies. In addition to these, in the lower banana (corresponding to softer energy spectra) we also find a very low frequency noise (VLFN) component below ~1 Hz. In the upper banana (corresponding to the softest energy spectra), the power spectra are dominated by the VLFN, with a peaked noise component around 20 Hz. We find that the frequencies of the kHz QPOs are well correlated with the position in the X-ray color-color diagram. For the frequency of the LFQPO and the break frequency of the broadband noise component, the relation appears more complex. Both of these frequencies increase when the frequency of the upper kHz QPO increases from 400 to 900 Hz, but at this frequency a jump in the values of the parameters occurs. We interpret this jump in terms of the gradual appearance of a QPO at the position of the break at high inferred mass accretion rate, while the previous LFQPO disappears. Simultaneously, another kind of noise appears with a break frequency of ~7 Hz, similar to the NBO of Z sources. The 100 Hz peaked noise does not seem to correlate with the position of the source in the color-color diagram but remains relatively constant in frequency. This component may be similar to several 100 Hz QPOs observed in black hole binaries.

  17. Artifactual responses when recording auditory steady-state responses.

    PubMed

    Small, Susan A; Stapells, David R

    2004-12-01

    The goal of this study was to investigate, in hearing-impaired participants who could not hear the stimuli, the possibility of artifactual auditory steady-state responses (ASSRs) when stimuli are presented at high intensities. ASSRs to single (60 dB HL) and multiple (20 to 50 dB HL; 500 to 4000 Hz) bone-conduction stimuli as well as single 114 to 120 dB HL air-conduction stimuli, were obtained using the Rotman MASTER system, using analog-to-digital (A/D) conversion rates of 500, 1000, and 1250 Hz. Responses (p < 0.05) were considered artifactual when their numbers exceeded that expected by chance. In some conditions, we also obtained ASSRs to "alternated" stimuli (stimuli inverted and ASSRs to the two polarities averaged). A total of 17 subjects were tested. Bone conduction results: 500 Hz A/D rate: Large-amplitude (43 to 1558 nV) artifactual ASSRs were seen at 40 and 50 dB HL for the 500 Hz carrier frequency. Smaller responses (28 to 53 nV) were also recorded at 20 dB HL for the 500 Hz carrier frequency. Artifactual ASSRs (17 to 62 nV) were seen at 40 dB HL and above for the 1000 Hz carrier frequency and at 50 dB HL for the 2000 Hz carrier frequency. Alternating the stimulus polarity decreased the amplitude and occurrence of these artifactual responses but did not eliminate responses for the 500 Hz carrier frequency at 40 dB HL and above. No artifactual responses were recorded for 4000 Hz stimuli for any condition. 1000 Hz A/D rate: Artifactual ASSRs (15 to 523 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 40 dB HL and above for the 1000 Hz carrier frequency. Artifactual responses were also obtained at 50 dB HL for a 2000 Hz carrier frequency but not at lower levels. Artifactual responses were not seen for the 4000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 and 2000 Hz carrier frequencies but did not change the results for the 500 Hz carrier frequency. 1250 Hz A/D rate: Artifactual ASSRs (16 to 220 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 60 dB HL and above for the 1000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 Hz carrier frequency but did not change the results for the 500 Hz carrier frequency. There were no artifactual responses at 2000 and 4000 Hz. Air conduction results: 500 Hz A/D rate: Artifactual ASSRs (49 to 153 nV) were seen for 114 to 120 dB HL stimuli for 500 and 1000 Hz carrier frequencies. Alternating the stimulus polarity removed these responses. There were no artifactual responses at 2000 and 4000 Hz. 1000 and 1250 Hz A/D rates: Artifactual ASSRs (19 to 55 nV) were seen for a 120 dB HL stimulus for a 1000 Hz carrier. Alternating the stimulus polarity removed these responses. High-intensity air- or bone-conduction stimuli can produce spurious ASSRs, especially for 500 and 1000 Hz carrier frequencies. High-amplitude stimulus artifact can result in energy that is aliased to exactly the modulation frequency. Choice of signal conditioning (electroencephalogram filter slope and low-pass cutoff) and processing (A/D rate) can avoid spurious responses due to aliasing. However, artifactual responses due to other causes may still occur for bone-conduction stimuli 50 dB HL and higher (and possibly for high-level air conduction). Because the phases of these spurious responses do not invert with inversion of stimulus, the possibility of nonauditory physiologic responses cannot be ruled out. The clinical implications of these results are that artifactual responses may occur for any patient for bone-conduction stimuli at levels greater than 40 dB HL and for high-intensity air-conduction stimuli used to assess patients with profound hearing loss.

  18. Subwavelength structure for sound absorption from graphene oxide-doped polyvinylpyrrolidone nanofibers

    NASA Astrophysics Data System (ADS)

    Qamoshi, Khadijeh; Rasuli, Reza

    2016-09-01

    We study the sound absorption of the reinforced polyvinylpyrrolidone nanofibers with graphene oxide. It is shown that reinforced nanofibers can acquire impedance-matched surface to airborne sound at special frequencies. To obtain such surface, nanofibers were spun with polyvinylpyrrolidone polymer that was doped by graphene oxide with concentrations of 0, 6 and 12 wt%. It was found that fibers without graphene oxide were spun continuously and randomly, whereas by doping with graphene oxide, the mode of fibers is changed and some nodes form on the fibers coating. The sound absorption coefficient was measured by an impedance tube based on 105341-1 ISO standard. Measurements in the frequency range from 700 to 1600 Hz show that use of graphene oxide as a reinforcing phase increases sound absorption coefficient of the samples at a frequency ~1500 Hz up to ~40 %. Angular eigenfrequency and dissipation coefficient of the samples were obtained by impedance measurement for the prepared samples. Results show that doping the polymer with graphene oxide causes an increase in the angular eigenfrequency and the dissipation coefficient.

  19. Laser frequency stabilization for LISA

    NASA Technical Reports Server (NTRS)

    Mueller, Guido; McNamara, Paul; Thorpe, Ira; Camp, Jordan

    2005-01-01

    The requirement on laser frequency noise in the Laser Interferometer Space Antenna (LISA) depends on the velocity and our knowledge of the position of each spacecraft of the interferometer. Currently it is assumed that the lasers must have a pre-stabilized frequency stability of 30Hz/square root of Hz over LISA'S most sensitive frequency band (3 mHz - 30 mHz). The intrinsic frequency stability of even the most stable com- mercial lasers is several orders of magnitude above this level. Therefore it is necessary to stabilize the laser frequency to an ultra-stable frequency reference which meets the LISA requirements. The baseline frequency reference for the LISA lasers are high finesse optical cavities based on ULE spacers. We measured the stability of two ULE spacer cavities with respect to each other. Our current best results show a noise floor at, or below, 30 Hz/square root of Hz above 3 mHz. In this report we describe the experimental layout of the entire experiment and discuss the limiting noise sources.

  20. Inhalation Frequency Controls Reformatting of Mitral/Tufted Cell Odor Representations in the Olfactory Bulb.

    PubMed

    Díaz-Quesada, Marta; Youngstrom, Isaac A; Tsuno, Yusuke; Hansen, Kyle R; Economo, Michael N; Wachowiak, Matt

    2018-02-28

    In mammals, olfactory sensation depends on inhalation, which controls activation of sensory neurons and temporal patterning of central activity. Odor representations by mitral and tufted (MT) cells, the main output from the olfactory bulb (OB), reflect sensory input as well as excitation and inhibition from OB circuits, which may change as sniff frequency increases. To test the impact of sampling frequency on MT cell odor responses, we obtained whole-cell recordings from MT cells in anesthetized male and female mice while varying inhalation frequency via tracheotomy, allowing comparison of inhalation-linked responses across cells. We characterized frequency effects on MT cell responses during inhalation of air and odorants using inhalation pulses and also "playback" of sniffing recorded from awake mice. Inhalation-linked changes in membrane potential were well predicted across frequency from linear convolution of 1 Hz responses; and, as frequency increased, near-identical temporal responses could emerge from depolarizing, hyperpolarizing, or multiphasic MT responses. However, net excitation was not well predicted from 1 Hz responses and varied substantially across MT cells, with some cells increasing and others decreasing in spike rate. As a result, sustained odorant sampling at higher frequencies led to increasing decorrelation of the MT cell population response pattern over time. Bulk activation of sensory inputs by optogenetic stimulation affected MT cells more uniformly across frequency, suggesting that frequency-dependent decorrelation emerges from odor-specific patterns of activity in the OB network. These results suggest that sampling behavior alone can reformat early sensory representations, possibly to optimize sensory perception during repeated sampling. SIGNIFICANCE STATEMENT Olfactory sensation in mammals depends on inhalation, which increases in frequency during active sampling of olfactory stimuli. We asked how inhalation frequency can shape the neural coding of odor information by recording from projection neurons of the olfactory bulb while artificially varying odor sampling frequency in the anesthetized mouse. We found that sampling an odor at higher frequencies led to diverse changes in net responsiveness, as measured by action potential output, that were not predicted from low-frequency responses. These changes led to a reorganization of the pattern of neural activity evoked by a given odorant that occurred preferentially during sustained, high-frequency inhalation. These results point to a novel mechanism for modulating early sensory representations solely as a function of sampling behavior. Copyright © 2018 the authors 0270-6474/18/382189-18$15.00/0.

  1. The Role of Oscillatory Phase in Determining the Temporal Organization of Perception: Evidence from Sensory Entrainment.

    PubMed

    Ronconi, Luca; Melcher, David

    2017-11-01

    Recent behavioral, neuroimaging, and neurophysiological studies have renewed the idea that the information processing within different temporal windows is linked to the phase and/or frequency of the ongoing oscillations, predominantly in the theta/alpha band (∼4-7 and 8-12 Hz, respectively). However, being correlational in nature, this evidence might reflect a nonfunctional byproduct rather than having a causal role. A more direct link can be shown with methods that manipulate oscillatory activity. Here, we used audiovisual entrainment at different frequencies in the prestimulus period of a temporal integration/segregation task. We hypothesized that entrainment would align ongoing oscillations and drive them toward the stimulation frequency. To reveal behavioral oscillations in temporal perception after the entrainment, we sampled the segregation/integration performance densely in time. In Experiment 1, two groups of human participants (both males and females) received stimulation either at the lower or the upper boundary of the alpha band (∼8.5 vs 11.5 Hz). For both entrainment frequencies, we found a phase alignment of the perceptual oscillation across subjects, but with two different power spectra that peaked near the entrainment frequency. These results were confirmed when perceptual oscillations were characterized in the time domain with sinusoidal fittings. In Experiment 2, we replicated the findings in a within-subject design, extending the results for frequencies in the theta (∼6.5 Hz), but not in the beta (∼15 Hz), range. Overall, these findings show that temporal segregation can be modified by sensory entrainment, providing evidence for a critical role of ongoing oscillations in the temporal organization of perception. SIGNIFICANCE STATEMENT The continuous flow of sensory input is not processed in an analog fashion, but rather is grouped by the perceptual system over time. Recent studies pinpointed the phase and/or frequency of the neural oscillations in the theta/alpha band (∼4-12 Hz) as possible mechanisms underlying temporal windows in perception. Here, we combined two innovative methodologies to provide more direct support for this evidence. We used sensory entrainment to align neural oscillations to different frequencies and then characterized the resultant perceptual oscillation with a temporal dense sampling of the integration/segregation performance. Our results provide the first evidence that the frequency of temporal segregation can be modified by sensory entrainment, supporting a critical role of ongoing oscillations in the integration/segregation of information over time. Copyright © 2017 Ronconi and Melcher.

  2. Synthesis, characterization and AC conductivity studies of silver doped conducting polyaniline/graphene/SrTiO3 composites

    NASA Astrophysics Data System (ADS)

    Vinay, K.; Shivakumar, K.; Ravikiran, Y. T.; Revanasiddappa, M.

    2018-05-01

    The present work is an investigation of ac conduction behaviour and dielectric response of Polyaniline/Ag/Graphene/SrTiO3 (PAGS) composite prepared by in-situ chemical oxidative interfacial polymerization using (NH4)2S2O8 as an oxidising agent at 0-5°C. The structural characterization of the samples was examined using FT-IR and XRD techniques. The ac conductivity and dielectric response of synthesized polymer composites were investigated at room temperature in the frequency range varying from 5 × 101 - 5 × 106 Hz using HIOKI make 3532-50 LCR Hi-tester. The ac conductivity increases with increase in frequency and follows the regular trend, the real dielectric constant (ɛ') and imaginary dielectric constant (ɛ'') decreases with increase in frequency and exhibits almost zero dielectric loss at higher frequencies, which suggests that the composite is a lossless material at frequencies beyond 3Hz.

  3. Monotonic, Creep-Rupture, and Fatigue Behavior of Carbon Fiber Reinforced Silicon Carbide (C/SiC) at an Elevated Temperature

    DTIC Science & Technology

    2004-03-01

    elevated temperature of 550 C. Cyclic loading of C/SiC was investigated at frequencies of 375 Hz , 10 Hz, 1 Hz, and 0.1 Hz. Creep-Rupture tests and tests that...is reduced when frequency of fatigue is increased. At high frequency fatigue (10Hz to 375 Hz ), C/SiC composites have longer cycle lives and time lives

  4. First results from the NEMO Test Site

    NASA Astrophysics Data System (ADS)

    Riccobene, Giorgio; NEMO Collaboration

    2007-03-01

    The NEMO (NEutrino Mediterranean Observatory) Collaboration is constructing, 25 km E from Catania (Sicily) at 2000 m depth, an underwater test site to perform long-term tests of prototypes and new technologies for an underwater high energy neutrino detector in the Mediterranean Sea. In this framework the collaboration deployed and operated an experimental apparatus for on-line monitoring of deep-sea noise. The station is equipped with 4 hydrophones operational in the range 30 Hz - 40 kHz. This interval of frequencies matches the range suitable for acoustic detection of high energy neutrino-induced showers in water. Hydrophone signals are digitized underwater at 96 kHz sampling frequency and 24 bits resolution. A custom software was developed to record data on high resolution 4-channels PCM .le. Data are used to model underwater acoustic noise as a function of frequency and time, a mandatory parametre for future acoustic neutrino detectors. Results indicate that the average noise in the site is compatible with noise produced in condition of sea surface agitation (sea state.)

  5. Low-frequency noise assessment metrics -- What do we know?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broner, N.

    1994-12-31

    The issue of sound quality in offices and other occupied spaces has been of continuing interest since the 1950s. Existing assessment methods do not adequately account for the low-frequency background sound (< 250 Hz) produced by operating heating, ventilating, and air-conditioning (HVAC) systems, in particular, low-frequency rumble. This paper discusses the results of ASHRAE-sponsored research in which more than 75 HVAC noise samples were collected, normalized, and categorized in terms of sound quality. The results support previous findings that a neutral curve has a slope of approximately {minus}5 decibels (dB) per octave. There is also support for the contention thatmore » the balanced noise criterion B (NCB) curves are overly conservative in the region from 63 to 500 Hz and overly permissive below 63 Hz when compared with the room criteria (RC) curves. A modified set of room sound quality (RSQ) curves -- the room sound quality (RSQ) curves -- is proposed.« less

  6. Thermal magnetic noise in a strip wound crystalline ferromagnetic core at 4.2 K

    NASA Astrophysics Data System (ADS)

    Snigirev, O. V.; Maslennikov, Yu. V.; Vitale, S.; Cerdonio, M.; Prodi, G. A.

    1996-01-01

    A dc SQUID magnetometer-based system has been developed and used to measure, in the frequency range 50-2300 Hz, the complex magnetic permeability μr(ν) and the magnetization noise at 4.2 K in a strip wound toroid. This toroidal core has been made of the 3-μm-thick ribbon fabricated from a crystalline magnetically soft alloy, Ultraperm. Below 1 kHz a constant value of -arg[μr(ν)]≊2×10-3 and 1/ν shaped noise spectral density have been measured. For frequencies higher than 1 kHz a linear growth of the imaginary part μr and a white noise have been found. The noise due to the sample is found in quantitative agreement with the standard fluctuation-dissipation formula for the thermal noise, while a comparison of the permeability imaginary part magnitude with the theoretical value has indicated a partially shorted windings in the toroid, which have decreased the toroid roll-off frequency down to 1 MHz.

  7. Ambient noise and temporal patterns of boat activity in the US Virgin Islands National Park.

    PubMed

    Kaplan, Maxwell B; Mooney, T Aran

    2015-09-15

    Human activity is contributing increasing noise to marine ecosystems. Recent studies have examined the effects of boat noise on marine fishes, but there is limited understanding of the prevalence of this type of sound source. This investigation tracks vessel noise on three reefs in the US Virgin Islands National Park over four months in 2013. Ambient noise levels ranged from 106 to 129dBrms re 1μPa (100Hz-20kHz). Boat noise occurred in 6-12% of samples. In the presence of boat noise, ambient noise in a low-frequency band (100-1000Hz) increased by >7dB above baseline levels and sound levels were significantly higher. The frequency with the most acoustic energy shifted to a significantly lower frequency when boat noise was present during the day. These results indicate the abundance of boat noise and its overlap with reef organism sound production, raising concern for the communication abilities of these animals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Wide Temperature Core Loss Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Schwarze, Gene E.

    1999-01-01

    100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.

  9. Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire

    NASA Astrophysics Data System (ADS)

    William, R. V.; Marikani, A.; Madhavan, D.

    2016-05-01

    Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO3 nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO3 nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO3 nano-wire show a frequency dependent property and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm2 at the frequency 4 kHz. The coercivity of BiFeO3 nano wire changes with variation of frequency from 1 kHz to 4 kHz.

  10. Dielectric characteristics of Mn-doped LaTiO3+δ ceramics

    NASA Astrophysics Data System (ADS)

    Chen, Yan; Cui, Yimin

    A series of ceramic composites of Mn-doped La1- x MnxTiO3+ δ and LaMnxTi1- x O3+ δ (x = 0.1, 0.2) were synthesized by conventional solid-state reaction method. The low-frequency complex dielectric properties of the composites were investigated as functions of temperature (77 K <= T <= 360 K) and frequency (100 Hz <= f <= 1 MHz), respectively. The dielectric constant of A-site doped samples is higher than that of B-site doped samples. The loss tangent of low doped samples is much less than that of high doped samples. The A-site doped composites exhibit intrinsic dielectric response with a dielectric constant of 40 in the temperature below 250 K. Interestingly, the dielectric constants of B-site doped ceramics increase slightly in the temperature range from 77 to 360 K. And it is clearly observed that extraordinarily high dielectric loss tangent ( 6) appear at low frequency (100 Hz) in LaMn0.2Ti0.8O3+ δ , which is 8 times larger than that of LaMn0.1Ti0.9O3+ δ , which indicates that the doped content can affect the intrinsic dielectric characteristics significantly.

  11. 47 CFR 90.253 - Use of frequency 5167.5 kHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...

  12. 47 CFR 90.253 - Use of frequency 5167.5 kHz.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...

  13. 47 CFR 90.253 - Use of frequency 5167.5 kHz.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...

  14. 47 CFR 90.253 - Use of frequency 5167.5 kHz.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...

  15. 47 CFR 90.253 - Use of frequency 5167.5 kHz.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of frequency 5167.5 kHz. 90.253 Section 90.253 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES... frequency 5167.5 kHz. The frequency 5167.5 kHz may be used by any station authorized under this part to...

  16. [Study the impacts of diagnosis on occupational noise-induced deafness after bring into the different high frequency hearing threshold weighted value].

    PubMed

    Xue, L J; Yang, A C; Chen, H; Huang, W X; Guo, J J; Liang, X Y; Chen, Z Q; Zheng, Q L

    2017-11-20

    Objective: Study of the results and the degree on occupational noise-induced deafness in-to the different high frequency hearing threshold weighted value, in order to provide theoretical basis for the re-vision of diagnostic criteria on occupational noise-induced deafness. Methods: A retrospective study was con-ducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. Based on the re-sults of the 3 hearing test for each test interval greater than 3 days in the hospital, the best threshold of each frequency was obtained, and based on the diagnostic criteria of occupational noise deafness in 2007 edition, Chi square test, t test and variance analysis were used to measure SPSS21.0 data, their differences are tested among the means of speech frequency and the high frequency weighted value into different age group, noise ex-posure group, and diagnostic classification between different dimensions. Results: 1. There were totally 168 cases in accordance with the study plan, male 154 cases, female 14 cases, the average age was 41.18 ±6.07 years old. 2. The diagnosis rate was increased into the weighted value of different high frequency than the mean value of pure speech frequency, the weighted 4 kHz frequency increased by 13.69% (χ(2)=9.880, P =0.002) , 6 kHz increased by 15.47% (χ(2)=9.985, P =0.002) and 4 kHz+6 kHz increased by15.47% (χ(2)=9.985, P =0.002) , the difference was statistically significant. The diagnostic rate of different high threshold had no obvious differ-ence between the genders. 3. The age groups were divided into less than or equal to 40years old group (A group) and 40-50 years old group (group B) , there were higher the diagnostic rate between high frequency weighted 4 kHz (A group χ(2)=3.380, P =0.050; B group χ(2)=4.054, P =0.032) , weighted 6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) , high frequency weighted 4 kHz+6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) than those of speech frequency average value in the same group on oc-cupational noise-induced deafness diagnosis rate, the difference was statistically significant. There was no sig-nificant difference between age groups (χ(2)=2.265, P =0.944) . 4. The better ear's mean value of pure speech fre-quency and the weighted values into different high frequency of working years on each group were compared, working years more than 10 years group was significantly higher than that of average thresholds of each frequen-cy band in 3-5 group ( F =2.271, P =0.001) , 6-10 group ( F =1.563, P =0.046) , the difference was statistically significant. The different high frequency weighted values were higher than those of the mean value of pure speech frequency, and the high frequency weighted 4 kHz+6 kHz had the highest frequency difference, with an average increase of 2.83 dB. 5. The diagnostic rate into weighted different high frequency was higher in the mild, moderate and severe grades than in the pure speech frequency. In the comparison of diagnosis for mild occupational noise-induced deafness, in addition to the weighted 3 kHz high frequency (χ(2)=3.117, P =0.077) had no significant difference, the weighted 4 kHz (χ(2)=10.835, P =0.001) , 6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz (χ(2)=6.315, P =0.012) , 3 kHz+6 kHz (χ(2)=6.315, P =0.012) , 4 kHz+6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz+6 kHz (χ(2)=7.667, P =0.002) were significantly higher than the diagnosis rate of the mean value of pure speech frequency. There was no significant difference between the two groups in the moderate and se-vere grades ( P >0.05) . Conclusion: Bring into different high frequency hearing threshold weighted value in-creases the diagnostic rate of occupational noise-induced deafness, the weighted 4 kHz, 6 kHz and 4 kHz+ 6 kHz high frequency value affects the result greatly, and the weighted 4 kHz+6 kHz high frequency hearing threshold value is maximum the effect on occupational noise-induced deafness diagnosis.

  17. Low-frequency and high-frequency distortion product otoacoustic emission suppression in humans

    PubMed Central

    Gorga, Michael P.; Neely, Stephen T.; Dierking, Darcia M.; Kopun, Judy; Jolkowski, Kristin; Groenenboom, Kristin; Tan, Hongyang; Stiegemann, Bettina

    2008-01-01

    Distortion product otoacoustic emission suppression (quantified as decrements) was measured for f2=500 and 4000 Hz, for a range of primary levels (L2), suppressor frequencies (f3), and suppressor levels (L3) in 19 normal-hearing subjects. Slopes of decrement-versus-L3 functions were similar at both f2 frequencies, and decreased as f3 increased. Suppression tuning curves, constructed from decrement functions, were used to estimate (1) suppression for on- and low-frequency suppressors, (2) tip-to-tail differences, (3) QERB, and (4) best frequency. Compression, estimated from the slope of functions relating suppression “threshold” to L2 for off-frequency suppressors, was similar for 500 and 4000 Hz. Tip-to-tail differences, QERB, and best frequency decreased as L2 increased for both frequencies. However, tip-to-tail difference (an estimate of cochlear-amplifier gain) was 20 dB greater at 4000 Hz, compared to 500 Hz. QERB decreased to a greater extent with L2 when f2=4000 Hz, but, on an octave scale, best frequency shifted more with level when f2=500 Hz. These data indicate that, at both frequencies, cochlear processing is nonlinear. Response growth and compression are similar at the two frequencies, but gain is greater at 4000 Hz and spread of excitation is greater at 500 Hz. PMID:18397024

  18. Development of high precision digital driver of acoustic-optical frequency shifter for ROG

    NASA Astrophysics Data System (ADS)

    Zhang, Rong; Kong, Mei; Xu, Yameng

    2016-10-01

    We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.

  19. Vestibular Evoked Myogenic Potential (VEMP) Testing: Normative Threshold Response Curves and Effects of Age

    PubMed Central

    Janky, Kristen L.; Shepard, Neil

    2009-01-01

    Background Vestibular Evoked Myogenic Potential (VEMP) testing has gained increased interest in the diagnosis of a variety of vestibular etiologies. Comparisons of P13 / N23 latency, amplitude and threshold response curves have been used to compare pathologic groups to normal controls. Appropriate characterization of these etiologies requires normative data across the frequency spectrum and age range. Purpose The objective of the current study was to test the hypothesis that significant changes in VEMP responses occur as a function of increased age across all test stimuli as well as characterize the VEMP threshold response curve across age. Research Design This project incorporated a prospective study design using a sample of convenience. Openly recruited subjects were assigned to groups according to age. Study Sample Forty-six normal controls ranging between 20 and 76 years of age participated in the study. Participants were separated by decade into 5 age categories from 20 to 60 plus years. Normal participants were characterized by having normal hearing sensitivity, no history of neurologic or balance/dizziness involvement and negative results on a direct office vestibular examination. Intervention VEMP responses were measured at threshold to click and 250, 500, 750, and 1000 Hz tone burst stimuli and at a suprathreshold level to 500 Hz toneburst stimuli at123 dBSPL. Data Collection and Analysis A mixed group factorial ANOVA and linear regression were performed to examine the effects of VEMP characteristics upon age. Results There were no significant differences between ears for any of the test parameters. There were no significant differences between age groups for n23 latency or amplitude in response to any of the stimuli. Significant mean differences did exist between age groups for p13 latency (250, 750, and 1000 Hz) and threshold (500 and 750 Hz). Age was significantly correlated with VEMP parameters. VEMP threshold was positively correlated (250, 500, 750, 1000 Hz); and amplitude was negatively correlated (500 Hz Maximum). The threshold response curves revealed best frequency tuning at 500 Hz with the highest thresholds in response to click stimuli. However, this best frequency tuning dissipated with increased age. VEMP response rates also decreased with increased age. Conclusion We have demonstrated that minor differences in VEMP responses occur with age. Given the reduced response rates and flattened frequency tuning curve for individuals over the age of 60, frequency tuning curves may not be a good diagnostic indicator for this age group. PMID:19764171

  20. In Vivo, High-Frequency Three-Dimensional Cardiac MR Elastography: Feasibility in Normal Volunteers

    PubMed Central

    Arani, Arvin; Glaser, Kevin L.; Arunachalam, Shivaram P.; Rossman, Phillip J.; Lake, David S.; Trzasko, Joshua D.; Manduca, Armando; McGee, Kiaran P.; Ehman, Richard L.; Araoz, Philip A.

    2016-01-01

    Purpose Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. Methods The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). Results The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. Conclusion This study motivates future evaluation of high-frequency 3D MRE in patient populations. PMID:26778442

  1. Wideband acoustic records of explosive volcanic eruptions at Stromboli: New insights on the explosive process and the acoustic source

    NASA Astrophysics Data System (ADS)

    Goto, A.; Ripepe, M.; Lacanna, G.

    2014-06-01

    Wideband acoustic waves, both inaudible infrasound (<20 Hz) and audible component (>20 Hz), generated by strombolian eruptions were recorded at 5 kHz and correlated with video images. The high sample rate revealed that in addition to the known initial infrasound, the acoustic signal includes an energetic high-frequency (typically >100 Hz) coda. This audible signal starts before the positive infrasound onset goes negative. We suggest that the infrasonic onset is due to magma doming at the free surface, whereas the immediate high-frequency signal reflects the following explosive discharge flow. During strong gas-rich eruptions, positively skewed shockwave-like components with sharp compression and gradual depression appeared. We suggest that successive bursting of overpressurized small bubbles and the resultant volcanic jets sustain the highly gas-rich explosions and emit the audible sound. When the jet is supersonic, microexplosions of ambient air entrained in the hot jet emit the skewed waveforms.

  2. Rhythmic coordination of hippocampal neurons during associative memory processing

    PubMed Central

    Rangel, Lara M; Rueckemann, Jon W; Riviere, Pamela D; Keefe, Katherine R; Porter, Blake S; Heimbuch, Ian S; Budlong, Carl H; Eichenbaum, Howard

    2016-01-01

    Hippocampal oscillations are dynamic, with unique oscillatory frequencies present during different behavioral states. To examine the extent to which these oscillations reflect neuron engagement in distinct local circuit processes that are important for memory, we recorded single cell and local field potential activity from the CA1 region of the hippocampus as rats performed a context-guided odor-reward association task. We found that theta (4–12 Hz), beta (15–35 Hz), low gamma (35–55 Hz), and high gamma (65–90 Hz) frequencies exhibited dynamic amplitude profiles as rats sampled odor cues. Interneurons and principal cells exhibited unique engagement in each of the four rhythmic circuits in a manner that related to successful performance of the task. Moreover, principal cells coherent to each rhythm differentially represented task dimensions. These results demonstrate that distinct processing states arise from the engagement of rhythmically identifiable circuits, which have unique roles in organizing task-relevant processing in the hippocampus. DOI: http://dx.doi.org/10.7554/eLife.09849.001 PMID:26751780

  3. A review of the perceptual effects of hearing loss for frequencies above 3 kHz.

    PubMed

    Moore, Brian C J

    2016-12-01

    Hearing loss caused by exposure to intense sounds usually has its greatest effects on audiometric thresholds at 4 and 6 kHz. However, in several countries compensation for occupational noise-induced hearing loss is calculated using the average of audiometric thresholds for selected frequencies up to 3 kHz, based on the implicit assumption that hearing loss for frequencies above 3 kHz has no material adverse consequences. This paper assesses whether this assumption is correct. Studies are reviewed that evaluate the role of hearing for frequencies above 3 kHz. Several studies show that frequencies above 3 kHz are important for the perception of speech, especially when background sounds are present. Hearing at high frequencies is also important for sound localization, especially for resolving front-back confusions. Hearing for frequencies above 3 kHz is important for the ability to understand speech in background sounds and for the ability to localize sounds. The audiometric threshold at 4 kHz and perhaps 6 kHz should be taken into account when assessing hearing in a medico-legal context.

  4. Regenerator Operation at Very High Frequencies for Microcryocoolers

    NASA Astrophysics Data System (ADS)

    Radebaugh, Ray; O'Gallagher, Agnes

    2006-04-01

    The size of Stirling and Stirling-type pulse tube cryocoolers is dominated by the size of the pressure oscillator. Such cryocoolers typically operate at frequencies up to about 60 Hz for cold-end temperatures above about 60 K. Higher operating frequencies would allow the size and mass of the pressure oscillator to be reduced for a given power input. However, simply increasing the operating frequency leads to large losses in the regenerator. The simple analytical equations derived here show how the right combination of frequency and pressure, along with optimized regenerator geometry, can lead to successful regenerator operation at frequencies up to 1 kHz. Efficient regenerator operation at such high frequencies is possible only with pressures of about 5 to 8 MPa and with very small hydraulic diameters and lengths. Other geometrical parameters must also be optimized for such conditions. The analytical equations are used to provide guidance to the right combination of parameters. We give example numerical calculations with REGEN3.2 in the paper for 60 Hz, 400 Hz, and 1000 Hz operation of optimized screen regenerators and show that the coefficient of performance at 400 Hz and 1000 Hz is about 78 % and 68 %, respectively, of that for 60 Hz when an average pressure of 7 MPa is used with the higher frequency, compared with 2.5 MPa for 60 Hz operation. The 1000 Hz coefficient of performance for parallel tubes is about the same as that of the screen geometry at 60 Hz. The compressor and cold-end swept volumes are reduced by a factor of 47 at 1000 Hz, compared with the 60 Hz case for the same input acoustic power, which can enable the development of microcryocoolers for MEMS applications.

  5. A look at motion in the frequency domain

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Ahumada, A. J., Jr.

    1983-01-01

    A moving image can be specified by a contrast distribution, c(x,y,t), over the dimensions of space x,y, and time t. Alternatively, it can be specified by the distribution C(u,v,w) over spatial frequency u,v and temporal frequency w. The frequency representation of a moving image is shown to have a characteristic form. This permits two useful observations. The first is that the apparent smoothness of time-sampled moving images (apparent motion) can be explained by the filtering action of the human visual system. This leads to the following formula for the required update rate for time-sampled displays. W(c)=W(l)+ru(l) where w(c) is the required update rate in Hz, W(l) is the limit of human temporal resolution in Hz, r is the velocity of the moving image in degrees/sec, and u(l) is the limit of human spatial resolution in cycles/deg. The second observation is that it is possible to construct a linear sensor that responds to images moving in a particular direction. The sensor is derived and its properties are discussed.

  6. Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

    NASA Technical Reports Server (NTRS)

    Ashpis, David E.; Laun, Matthew C.

    2014-01-01

    We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

  7. Noise reduction and control in mode-locked semiconductor diode lasers for use in next-generation all-optical analog-to-digital converters

    NASA Astrophysics Data System (ADS)

    DePriest, Christopher M.; Abeles, Joseph H.; Braun, Alan; Delfyett, Peter J., Jr.

    2000-07-01

    External-cavity, actively-modelocked semiconductor diode lasers (SDLs) have proven to be attractive candidates for forming the backbone of next-generation analog-to-digital converters (ADCs), which are currently being developed to sample signals at repetition rates exceeding several GHz with up to 12 bits of digital resolution. Modelocked SDLs are capable of producing waveform-sampling pulse trains with very low temporal jitter (phase noise) and very small fluctuations in pulse height (amplitude noise)--two basic conditions that must be met in order for high-speed ADCs to achieve projected design goals. Single-wavelength modelocked operation (at nominal repetition frequencies of 400 MHz) has produced pulse trains with very low amplitude noise (approximately 0.08%), and the implementation of a phase- locked-loop has been effective in reducing the system's low- frequency phase noise (RMS timing jitter for offset frequencies between 10 Hz and 10 kHz has been reduced from 240 fs to 27 fs).

  8. Investigation of low-frequency-oscillating water flow in metal foam with 10 pores per inch

    NASA Astrophysics Data System (ADS)

    Bağcı, Ö.; Arbak, A.; De Paepe, M.; Dukhan, N.

    2018-01-01

    In this study, oscillating water flow in metal foam with open cells is investigated experimentally. The metal foam sample has a porosity of 88% and 10 pores. The water was oscillated in the test section with three frequencies between 0.116 Hz and 0.348 Hz, which are considered low for water oscillation, and three flow displacements ranging between 74.35 mm and 111.53 mm. The combinations of frequencies of displacements were studied for their impacts of dimensional and non-dimensional pressure loss quantities. To this purpose, friction factor was correlated as a function of kinetic Reynolds number. The same metal foam sample was studied by exposing it to steady-state water flow to investigate its permeability and drag coefficient in low-velocity flow regimes. The friction factor distribution for oscillating flow was found to be over that found for steady state. The outcomes of the study are important for studying heat transfer under the same flow conditions.

  9. Relationships between electrical properties and petrography of El-Maghara sandstone formations, Egypt

    NASA Astrophysics Data System (ADS)

    Kassab, Mohamed A.; Gomaa, Mohamed M.; Lala, Amir M. S.

    2017-06-01

    Realization of electrical and petrography of rocks is absolutely necessary for geophysical investigations. The petrographical, petrophysical and electrical properties of sandstone rocks (El-Maghara Formation, North Sinai, Egypt) will be discussed in the present work. The goal of this paper was to highlight interrelations between electrical properties in terms of frequency (conductivity, permittivity and impedance) and petrography, as well as mineral composition. Electrical properties including (conductivity and dielectric constant) were measured at room temperature and humidity of (∼35%). The frequency range used will be from 10 Hz to 100 kHz. Slight changes between samples in electrical properties were found to result from changes in composition and texture. Electrical properties generally change with grain size, shape, sorting, mineralogy and mineral composition. The dielectric constant decreases with frequency and increases with increasing clay content. The conductivity increases with the increase in conductor channels among electrodes. Many parameters can combine together to lead to the same electrical properties. The samples are mainly composed of sand with clay and carbonate.

  10. Do manatees talk during sex?

    NASA Astrophysics Data System (ADS)

    Self-Sullivan, Caryn; Gilbertson, Tamra; Evans, William E.

    2002-05-01

    On January 13, 1999, manatee vocalizations were recorded during a mating herd event in the Orange River, Florida. Although copulation could not be observed, multiple males were observed with exposed penises. During one 25 min sample (1300-1325 h), over 400 manatee signals were recorded. In March 2000, each signal was captured and digitized from the analog tape using a Marantz PMD 501, Ashly equalizer (gain=0, filter=0), MAC 8100, and Canary 1.2.1. In general, signals were 100-200 ms in length, highly harmonic (up to 8 harmonics ranging from 1 to 16 kHz), with little or no frequency modulation. Intervals between signals ranged from less than 1 s to 14 s (mean = 3 s), indicating that manatees do indeed talk (a lot) during sex. Noise from two passing boats was also recorded during the sample period. One abnormally low-frequency signal (0.4 kHz) was recorded during one boat pass. This apparent manatee vocalization could be seen and heard below the boat noise frequency band.

  11. Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Kemery, Amy; Camp, Jordan

    2004-01-01

    We evaluated thermal noise (Brownian motion) in a rigid reference cavity used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with t.he direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency- reference cavity of order 1 Hz/square root Hz(0.01 Hz/square root Hz) at 10 mHz (100 Hz) at room temperature. This level coincides with the world-highest level stabilization results.

  12. Preliminary Shear Velocity Tomography of Mt St Helens, Washington from iMUSH Array

    NASA Astrophysics Data System (ADS)

    Crosbie, K.; Abers, G. A.; Creager, K. C.; Moran, S. C.; Denlinger, R. P.; Ulberg, C. W.

    2015-12-01

    The imaging Magma Under Mount St Helens (iMUSH) experiment will illuminate the crust beneath Mt St Helens volcano. The ambient noise tomography (ANT) component of this experiment measures shear velocity structure, which is more sensitive than P velocity to the presence of melt and other pore fluids. Seventy passive-source broadband seismometers for iMUSH were deployed in the summer of 2014 in a dense array of 100 Km diameter with a 10 km station spacing. We cross correlated ambient noise in 120 s windows and summed the result over many months for pairs of stations. Then frequency-domain methods on these cross correlations are employed to measure the phase velocities (Ekström et al. Geophys Rev Lett, 2009). Unlike velocities attained by group velocity methods, velocities for path lengths as small as one wavelength can be measured, enabling analysis of higher frequency signals and increasing spatial resolution. The minimum station spacing from which signals can be recovered ranges from 12 km at 0.18 Hz, a frequency that dominantly samples the upper crust to 20 km, to 37 km at 0.04 Hz, a frequency sensitive to structure through the crust and uppermost mantle, with lower spacing at higher frequencies. These phase velocities are tomographically inverted to obtain shear velocity maps for each frequency, assuming ray theory. Initial shear velocity maps for frequencies between 0.04-0.18 Hz reveal low-velocity sediments in the Puget Lowland west of Mount St Helens at 0.16-0.18 Hz, and a low velocity zone near 0.10 Hz between Mt Rainier and Mt Adams, east of Mount St Helens. The latter may reflect large-scale crustal plumbing of the arc between volcanic centers. In subsequent analyses these ANT results will be jointly inverted with receiver functions in order to further resolve crustal and upper mantle structure.

  13. Test-retest reliability of pure-tone thresholds from 0.5 to 16 kHz using Sennheiser HDA 200 and Etymotic Research ER-2 earphones.

    PubMed

    Schmuziger, Nicolas; Probst, Rudolf; Smurzynski, Jacek

    2004-04-01

    The purposes of the study were: (1) To evaluate the intrasession test-retest reliability of pure-tone thresholds measured in the 0.5-16 kHz frequency range for a group of otologically healthy subjects using Sennheiser HDA 200 circumaural and Etymotic Research ER-2 insert earphones and (2) to compare the data with existing criteria of significant threshold shifts related to ototoxicity and noise-induced hearing loss. Auditory thresholds in the frequency range from 0.5 to 6 kHz and in the extended high-frequency range from 8 to 16 kHz were measured in one ear of 138 otologically healthy subjects (77 women, 61 men; mean age, 24.4 yr; range, 12-51 yr) using HDA 200 and ER-2 earphones. For each subject, measurements of thresholds were obtained twice for both transducers during the same test session. For analysis, the extended high-frequency range from 8 to 16 kHz was subdivided into 8 to 12.5 and 14 to 16 kHz ranges. Data for each frequency and frequency range were analyzed separately. There were no significant differences in repeatability for the two transducer types for all frequency ranges. The intrasession variability increased slightly, but significantly, as frequency increased with the greatest amount of variability in the 14 to 16 kHz range. Analyzing each individual frequency, variability was increased particularly at 16 kHz. At each individual frequency and for both transducer types, intrasession test-retest repeatability from 0.5 to 6 kHz and 8 to 16 kHz was within 10 dB for >99% and >94% of measurements, respectively. The results indicated a false-positive rate of <3% in reference to the criteria for cochleotoxicity for both transducer types. In reference to the Occupational Safety and Health Administration Standard Threshold Shift criteria for noise-induced hazards, the results showed a minor false-positive rate of <1% for the HDA 200. Repeatability was similar for both transducer types. Intrasession test-retest repeatability from 0.5 to 12.5 kHz at each individual frequency including the frequency range susceptible to noise-induced hearing loss was excellent for both transducers. Repeatability was slightly, but significantly poorer in the frequency range from 14 to 16 kHz compared with the frequency ranges from 0.5 to 6 or 8 to 12.5 kHz. Measurements in the extended high-frequency range from 8 to 14 kHz, but not up to 16 kHz, may be recommended for monitoring purposes.

  14. 47 CFR 80.361 - Frequencies for narrow-band direct-printing (NBDP), radioprinter and data transmissions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...

  15. 47 CFR 80.361 - Frequencies for narrow-band direct-printing (NBDP), radioprinter and data transmissions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...

  16. 47 CFR 80.361 - Frequencies for narrow-band direct-printing (NBDP), radioprinter and data transmissions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...

  17. 47 CFR 80.361 - Frequencies for narrow-band direct-printing (NBDP), radioprinter and data transmissions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...

  18. 47 CFR 80.361 - Frequencies for narrow-band direct-printing (NBDP), radioprinter and data transmissions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for NBDP and data transmissions (kHz) 4 MHz Coast Ship 6 MHz Coast Ship 8 MHz Coast Ship 12 MHz Coast... frequencies. Non-Paired NBDP Channels (kHz) Channel series: 1 4202.5 6300.5 8396.5 12560.0 16785.0 18893.0....0 (c) Distress and calling. The frequencies 2174.5 kHz, 4177.5 kHz, 6268.0 kHz, 8376.5 kHz, 12520.0...

  19. Influence of Lu2O3 on electrical and microstructural properties of CaCu3Ti4O12 ceramics

    NASA Astrophysics Data System (ADS)

    Xu, Dong; Wang, Biao; Lin, Yuanhua; Jiao, Lei; Yuan, Hongming; Zhao, Guoping; Cheng, Xiaonong

    2012-07-01

    In this work, the influence of Lu2O3 doped on the dielectric and electrical properties of CaCu3Ti4O12 was reported. Lu2O3-doped CCTO was prepared by a conventional solid state technique using CuO, TiO2, and CaCO3 as starting materials. The samples were studied by X-ray diffraction (XRD) and scanning electron microscopy (SEM); dielectric measurements were measured in the 102 Hz-107 Hz frequency range at room temperature; and the nonlinear behavior of all samples was measured. The doping of Lu2O3 resulted in an increase in the dielectric constant of CCTO, but decreased the stability of the frequency dependence. Increasing concentrations of Lu2O3 resulted in decreasing nonlinear coefficients.

  20. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring.

    PubMed

    Kuk, Seungho; Kim, Junha; Park, Yongtae; Kim, Hyogon

    2018-04-27

    The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different countries. Specifically, we gradually remove high frequency components in the traces, while observing the correlation changes. As a result, we find that the human coexistence detection indeed tends to be no less, if not more, effective at the sampling frequency of 1 Hz or even less. This is because unlike the other applications that require centimeter-level precision, the human contacts detected anywhere within a couple of meters are valid for our purpose. With the typical smartphone battery capacity and at the 1 Hz sensing, the battery consumption is well below an hour, which is smaller by more than two hours compared with 10 Hz sampling and by almost eleven hours compared with 200 Hz sampling. With other tasks running simultaneously on smartphones, the energy saving aspect will only become more critical. Therefore, we conclude that sensing the ambient magnetic field at 1 Hz is sufficient for the human contact monitoring purpose. We expect that this finding will have a significant practicability implication in the smartphone magnetometer-based contact monitoring applications in general.

  1. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring

    PubMed Central

    Kuk, Seungho; Kim, Junha; Park, Yongtae; Kim, Hyogon

    2018-01-01

    The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different countries. Specifically, we gradually remove high frequency components in the traces, while observing the correlation changes. As a result, we find that the human coexistence detection indeed tends to be no less, if not more, effective at the sampling frequency of 1 Hz or even less. This is because unlike the other applications that require centimeter-level precision, the human contacts detected anywhere within a couple of meters are valid for our purpose. With the typical smartphone battery capacity and at the 1 Hz sensing, the battery consumption is well below an hour, which is smaller by more than two hours compared with 10 Hz sampling and by almost eleven hours compared with 200 Hz sampling. With other tasks running simultaneously on smartphones, the energy saving aspect will only become more critical. Therefore, we conclude that sensing the ambient magnetic field at 1 Hz is sufficient for the human contact monitoring purpose. We expect that this finding will have a significant practicability implication in the smartphone magnetometer-based contact monitoring applications in general. PMID:29702586

  2. Effects of Ultrasound Frequency and Tissue Stiffness on the Histotripsy Intrinsic Threshold for Cavitation

    PubMed Central

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J.; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-01-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated a cavitation cloud can be formed by a single pulse with one high amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1–2 cycles produced by 345 kHz, 500 kHz, 1.5 MHz, and 3 MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results demonstrated that the intrinsic threshold (the negative pressure at which probability=0.5) is independent of stiffness for Young’s moduli (E) < 1 MPa with only a small increase (~2–3 MPa) in the intrinsic threshold for tendon (E=380 MPa). Additionally, results for all samples showed only a small increase of ~2–3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7–30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly impacted by tissue stiffness or ultrasound frequency in hundreds of kHz to MHz range. PMID:25766571

  3. In vivo, high-frequency three-dimensional cardiac MR elastography: Feasibility in normal volunteers.

    PubMed

    Arani, Arvin; Glaser, Kevin L; Arunachalam, Shivaram P; Rossman, Phillip J; Lake, David S; Trzasko, Joshua D; Manduca, Armando; McGee, Kiaran P; Ehman, Richard L; Araoz, Philip A

    2017-01-01

    Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. This study motivates future evaluation of high-frequency 3D MRE in patient populations. Magn Reson Med 77:351-360, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Effective masking levels for 500 and 2000 Hz bone conduction auditory steady state responses in infants and adults with normal hearing.

    PubMed

    Small, Susan A; Smyth, Aisling; Leon, Griselle

    2014-01-01

    Few studies have investigated effective masking levels (EMLs) needed to isolate the test ear for bone conduction assessments in infants. The objective of this study was to determine EMLs for 500 and 2000 Hz bone conduction auditory steady state responses (ASSRs) to amplitude (AM)/frequency-modulated (FM) stimuli for infants and adults with normal hearing. Maturational factors that contribute to infant-adult differences in EMLs will also be investigated. The present study and previously published 1000 and 4000 Hz EML data will be compared to investigate EML across four frequencies. These findings will provide a starting point for implementing clinical masking for infant bone conduction testing using physiological measures. Participants were 15 infants (7 to 35 weeks) and 15 adults (21 to 56 years) with normal hearing. Bone-conducted single ASSR stimuli (research MASTER) were 100% AM and 25% FM at 85 and 101 Hz for 500 and 2000 Hz carrier frequencies, respectively. They were presented at 25 and 35 dB HL for 500 Hz and at 35 and 45 dB HL for 2000 Hz for both infants and adults (approximately 10 and 20 dB SL at each frequency for infants). Air-conducted narrowband maskers were presented to both ears simultaneously. Real-ear to coupler differences were measured to account for differences in the sound pressure developed in infant and adult ear canals as a result of ear-canal size. Data analyses were conducted for mean EMLs across frequency (500 to 4000 Hz) and between age groups. Masked and unmasked ASSR amplitudes were compared for 500 and 2000 Hz. Both infants and adults required much more masking (25 to 33 dB) to eliminate responses at 500 compared with 2000 Hz. On average, infants required 16 dB more masking at 500 Hz and similar amounts of masking at 2000 Hz compared with adults. When adjusted for ear-canal size and bone conduction sensitivity, the pattern of results did not change. Across all four frequencies, infants showed a systematic decrease in mean EMLs with an increase in frequency; all pair-wise comparisons were significant except 2000 versus 4000 Hz. Adults showed smaller frequency-dependent changes in EML (only significantly greater for 500 versus 2000 Hz and 4000 Hz). When ear-canal size and bone conduction sensitivity were taken into account, only 500 Hz required more masking than other frequencies in infants; there were no significant frequency-dependent trends for adults, although the greater EMLs at 1000 versus 2000 Hz and 4000 Hz approached significance. Unmasked and masked amplitudes tended to be larger for 2000 Hz but not for 500 Hz when comparing infants with adults. EMLs appropriate for infants for bone conduction ASSRs elicited to AM/FM stimuli are considerably higher at 500 compared with 2000 Hz. Infants also need more masking at 500 Hz compared with adults but the same amount of masking at 2000 Hz. Comparisons across four frequencies reveal a systematic decrease in EML with an increase in frequency in infants, which is not apparent in adults. Recommended EMLs for AM/FM bone-conducted ASSR stimuli presented at 35 dB HL for 500, 1000, 2000, and 4000 Hz, respectively, are: (1) infants: 81, 68, 59, and 45 dB SPL, and (2) adults: 66, 63, 59, and 55 dB SPL.

  5. Modeling sound transmission of human middle ear and its clinical applications using finite element analysis.

    PubMed

    Chen, Shou-I; Lee, Ming-Hsiao; Yao, Chih-Min; Chen, Peir-Rong; Chou, Yuan-Fang; Liu, Tien-Chen; Song, Yu-Lin; Lee, Chia-Fone

    2013-03-01

    We have developed a new finite element (FE) model of human right ear, including the accurate geometry of middle ear ossicles, external ear canal, tympanic cavity, and mastoid cavity. The FE model would be suitable to study the dynamic behaviors of pathological middle ear conditions, including changes of stapedial ligament stiffness, tensor tympani ligament (TTL), and tympanic membrane (TM) stiffness and thickness. Increasing stiffness of stapedial ligament has substantial effect on stapes footplate movement, especially at low frequencies, but less effect on umbo movement. Softer TTL will result in increasing umbo and stapes footplate displacement, especially at low frequencies (f<1000Hz). When the TTL was detached, the vibration amplitude of umbo increased by 6dB at 600Hz and two peaks (300 and 600Hz) were found in the vibration amplitude of stapes footplate. Increasing the stiffness of tensor tympani resulted in a slightly decreased umbo amplitude at very low frequencies (f<500Hz) and significantly decreased displacement up to 12dB at middle frequencies (1000Hz1500Hz. As (TM) thickness was increased, the umbo displacement was reduced, especially at very low frequencies (f<600Hz). Otherwise, the stapes displacement was reduced at all frequencies. Copyright © 2013. Published by Elsevier B.V.

  6. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

    PubMed Central

    Dotsinsky, Ivan

    2005-01-01

    Background Public access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Method Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. Results The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. Conclusion The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression. PMID:16309558

  7. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators.

    PubMed

    Dotsinsky, Ivan

    2005-11-26

    Public access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  8. Multiple-quantum spin counting in magic-angle-spinning NMR via low-power symmetry-based dipolar recoupling

    NASA Astrophysics Data System (ADS)

    Teymoori, Gholamhasan; Pahari, Bholanath; Viswanathan, Elumalai; Edén, Mattias

    2013-11-01

    By using a symmetry-based R281R28-1 double-quantum (2Q) dipolar recoupling sequence, we demonstrate high-order multiple-quantum coherence (MQC) excitation at fast magic-angle spinning (MAS) frequencies up to 34 kHz. This scheme combines several attractive features, such as a relatively high dipolar scaling factor, good compensation to rf-errors, isotropic and anisotropic chemical shifts, as well as an ultra-low radio-frequency (rf) power requirement. The latter translates into nutation frequencies below 30 kHz for MAS rates up to 60 kHz, thereby permitting rf application for very long excitation periods without risk of damaging the NMR probehead or sample, while the compensation to chemical shifts improves as the MAS rate increases. 31P MQC spin counting is demonstrated on powders of calcium hydroxyapatite (Ca5(PO4)3OH) and anhydrous sodium diphosphate (Na4P2O7), from which all even coherence orders up to 30 and 14 were detected, respectively, over the respective MAS ranges of 15-24 kHz and 20-34 kHz. The amplitude distributions among the 31P MQC orders depend on the precise nutation frequency during recoupling, despite that the highest detected order was relatively insensitive to this parameter. An observed gradual transition from a Gaussian to exponential functionality of the MQC amplitude-profile is discussed in relation to the prevailing approach to derive spin-cluster sizes by fitting the MQC amplitude-distribution to a Gaussian decay, where minor systematic deviations between the model and experimental data are frequently reported.

  9. Increased Release of Serotonin in the Spinal Cord During Low, But Not High, Frequency Transcutaneous Electric Nerve Stimulation in Rats With Joint Inflammation

    PubMed Central

    Sluka, Kathleen A.; Lisi, Tammy L.; Westlund, Karin N.

    2009-01-01

    Objective To determine the release pattern of serotonin and noradrenaline in the spinal cord in response to transcutaneous electric nerve stimulation (TENS) delivered at low or high frequency. Design Prospective randomized allocation of 3 treatments. Setting Research laboratory. Animals Male Sprague-Dawley rats (weight range, 250–350g). Intervention Knee joints of rats were inflamed with a mixture of 3% carrageenan and 3% kaolin for 24 hours prior to placement of push-pull cannulae into the dorsal horn of the spinal cord. Push-pull samples were collected in 10-minute intervals before, during, and after treatment with low-frequency TENS (4Hz), high-frequency TENS (100Hz), or sham TENS. TENS was applied to the inflamed knee joint for 20 minutes at sensory intensity and 100-μs pulse duration. Push-pull samples were analyzed for serotonin and noradrenaline by high performance liquid chromatography with coulemetric detection. Main Outcome Measures Spinal concentrations of serotonin and noradrenaline. Results Low-frequency TENS significantly increased serotonin concentrations during and immediately after treatment. There was no change in serotonin with high-frequency TENS, nor was there a change in noradrenaline with low- or high-frequency TENS. Conclusions Low-frequency TENS releases serotonin in the spinal cord to produce antihyperalgesia by activation of serotonin receptors. PMID:16876561

  10. Relative electroencephalographic desynchronization and synchronization in humans to emotional film content: an analysis of the 4-6, 6-8, 8-10 and 10-12 Hz frequency bands.

    PubMed

    Krause, C M; Viemerö, V; Rosenqvist, A; Sillanmäki, L; Aström, T

    2000-05-26

    The reactivity of different narrow electroencephalographic (EEG) frequencies (4-6, 6-8, 8-10 and 10-12 Hz) to three types of emotionally laden film clips (aggressive, sad, neutral) were examined. We observed that different EEG frequency bands responded differently to the three types of film content. In the 4-6 Hz frequency band, the viewing of aggressive film content elicited greater relative synchronization as compared the responses elicited by the viewing of sad and neutral film content. The 6-8 Hz and 8-10 Hz frequency bands exhibited reactivity to the chronological succession of film viewing whereas the responses of the 10-12 Hz frequency band evolved within minutes during film viewing. Our results propose dissociations between the responses of different frequencies within the EEG to different emotion-related stimuli. Narrow frequency band EEG analysis offers an adequate tool for studying cortical activation patterns during emotion-related information processing.

  11. Admittance of multiterminal quantum Hall conductors at kilohertz frequencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernández, C.; Consejo, C.; Chaubet, C., E-mail: christophe.chaubet@univ-montp2.fr

    2014-03-28

    We present an experimental study of the low frequency admittance of quantum Hall conductors in the [100 Hz, 1 MHz] frequency range. We show that the frequency dependence of the admittance of the sample strongly depends on the topology of the contacts connections. Our experimental results are well explained within the Christen and Büttiker approach for finite frequency transport in quantum Hall edge channels taking into account the influence of the coaxial cables capacitance. In the Hall bar geometry, we demonstrate that there exists a configuration in which the cable capacitance does not influence the admittance measurement of the sample. In thismore » case, we measure the electrochemical capacitance of the sample and observe its dependence on the filling factor.« less

  12. REFAB: A Prototype Graphical Frontend for the RESA Naval Wargame

    DTIC Science & Technology

    1990-06-01

    knots (dB) NBN - 6 0:999999 Signature line frequencies (Hz) 0:500 NB noise (dB) HFDF - I alphanumeric HFDF name DECM 1 YESINO DECEPTION (RADAR...dB) BBD3 - 1 0:500 BB @300 Hz noise at 05/10/15120/25/30 knots (dB) NBD - 6 0:999999 Signature line frequencies (Hz) 0:500 Diesel NB noise (dB) 48...Number Range of Values Description LFREQ 1 10:20000 Low end of band frequency (Hz) HFREQ 1 10:20000 High end of band frequency (Hz) HZBW 1 0:360

  13. A Novel Energy-Efficient Approach for Human Activity Recognition

    PubMed Central

    Zheng, Lingxiang; Wu, Dihong; Ruan, Xiaoyang; Weng, Shaolin; Tang, Biyu; Lu, Hai; Shi, Haibin

    2017-01-01

    In this paper, we propose a novel energy-efficient approach for mobile activity recognition system (ARS) to detect human activities. The proposed energy-efficient ARS, using low sampling rates, can achieve high recognition accuracy and low energy consumption. A novel classifier that integrates hierarchical support vector machine and context-based classification (HSVMCC) is presented to achieve a high accuracy of activity recognition when the sampling rate is less than the activity frequency, i.e., the Nyquist sampling theorem is not satisfied. We tested the proposed energy-efficient approach with the data collected from 20 volunteers (14 males and six females) and the average recognition accuracy of around 96.0% was achieved. Results show that using a low sampling rate of 1Hz can save 17.3% and 59.6% of energy compared with the sampling rates of 5 Hz and 50 Hz. The proposed low sampling rate approach can greatly reduce the power consumption while maintaining high activity recognition accuracy. The composition of power consumption in online ARS is also investigated in this paper. PMID:28885560

  14. High-latitude distributions of plasma waves and spatial irregularities from DE 2 alternating current electric field observations

    NASA Technical Reports Server (NTRS)

    Heppner, J. P.; Liebrecht, M. C.; Maynard, N. C.; Pfaff, R. F.

    1993-01-01

    The high-latitude spatial distributions of average signal intensities in 12 frequency channels between 4 Hz and 512 kHz as measured by the ac electric field spectrometers on the DE-2 spacecraft are analyzed for 18 mo of measurements. In MLT-INL (magnetic local time-invariant latitude) there are three distinct distributions that can be identified with 4-512 Hz signals from spatial irregularities and Alfven waves, 256-Hz to 4.1-kHz signals from ELF hiss, and 4.1-64 kHz signals from VLF auroral hiss, respectively. Overlap between ELF hiss and spatial irregularity signals occurs in the 256-512 Hz band. VLF hiss signals extend downward in frequency into the 1.0-4.1 kHz band and upward into the frequency range 128-512 kHz. The distinctly different spatial distribution patterns for the three bands, 4-256 Hz, 512-1204 Hz, and 4.1-64 kHz, indicate a lack of any causal relationships between VLF hiss, ELF hiss, and lower-frequency signals from spatial irregularities and Alfven waves.

  15. Electrical and morphological properties of magnetocaloric nano ZnNi ferrite

    NASA Astrophysics Data System (ADS)

    Hemeda, O. M.; Mostafa, Nasser Y.; Abd Elkader, Omar H.; Hemeda, D. M.; Tawfik, A.; Mostafa, M.

    2015-11-01

    A series of Zn1-xNixFe2O4 nano ferrite (with x=0, 0.2, 0.4, 0.6, 0.8, and 1) compositions were synthesized using the combustion technique. The powder samples were characterized by XRD. The X-ray analysis showed that the samples were single phase spinel cubic structure. The AC resistivity decreases by increasing the frequency from 1 kHz to 10 kHz. As the frequency of the applied field increases the hopping of charge carrier also increase, thereby decreasing the resistivity. A shift in dielectric maximum is observed toward higher temperature with increasing the Ni content from 536 K to 560 K at 1 kHz. The HRTEM (high resolution TEM) images of four compositions have lattice spacing which confirms the crystalline nature of the samples. The surface morphology SEM of the sample consists of some grains with relatively homogenies distribution with an average size varying from 0.85 to 0.92 μm. The values for entropy change in this work are still small but are significally higher than the values that have been reported for iron oxide nanoparticle. The magnetic entropy change was calculated from measurements of M (H, T) where H is the magnetic field and T is the temperature. The maximum value of entropy change (ΔS) obtained near Curie temperature which makes these material candidates for magnetocaloric applications.

  16. Thermal Images of Seeds Obtained at Different Depths by Photoacoustic Microscopy (PAM)

    NASA Astrophysics Data System (ADS)

    Domínguez-Pacheco, A.; Hernández-Aguilar, C.; Cruz-Orea, A.

    2015-06-01

    The objective of the present study was to obtain thermal images of a broccoli seed ( Brassica oleracea) by photoacoustic microscopy, at different modulation frequencies of the incident light beam ((0.5, 1, 5, and 20) Hz). The thermal images obtained in the amplitude of the photoacoustic signal vary with each applied frequency. In the lowest light frequency modulation, there is greater thermal wave penetration in the sample. Likewise, the photoacoustic signal is modified according to the structural characteristics of the sample and the modulation frequency of the incident light. Different structural components could be seen by photothermal techniques, as shown in the present study.

  17. Investigation of Performance, Noise, and Detectability Characteristics of Remotely Piloted Vehicle (RPV) Propellers

    DTIC Science & Technology

    1980-06-01

    characteristics of small-scale propellers in forward flight, the results of these studies were used as guidelines to arrive at the quiet RPV propeller designs...8217 FREQUENY, HZ (b) FREQUENCY, HZ WITHOUT THE DUCT 8= 900 WITH THE DUCT 8-W= 10Hz BPF =195 Hz Figure 24. Spectral Comparisons of a Two-Bladed Propeller (BD3...bS 1P95 REAR BLADES 114 114 " 84-J 4 64 44 44 0 512 1024 1536 2048 2560 0 512 1024 1536 2046 2560 FREQUENCY, HZ FREQUENCY, Hz "| 95H BPF :195 Hz (C

  18. Gravitational Wave (GW) Classification, Space GW Detection Sensitivities and AMIGO (Astrodynamical Middle-frequency Interferometric GW Observatory)

    NASA Astrophysics Data System (ADS)

    Ni, Wei-Tou

    2018-01-01

    After first reviewing the gravitational wave (GW) spectral classification. we discuss the sensitivities of GW detection in space aimed at low frequency band (100 nHz-100 mHz) and middle frequency band (100 mHz-10 Hz). The science goals are to detect GWs from (i) Supermassive Black Holes; (ii) Extreme-Mass-Ratio Black Hole Inspirals; (iii) Intermediate-Mass Black Holes; (iv) Galactic Compact Binaries; (v) Stellar-Size Black Hole Binaries; and (vi) Relic GW Background. The detector proposals have arm length ranging from 100 km to 1.35×109 km (9 AU) including (a) Solar orbiting detectors and (b) Earth orbiting detectors. We discuss especially the sensitivities in the frequency band 0.1-10 μHz and the middle frequency band (0.1 Hz-10 Hz). We propose and discuss AMIGO as an Astrodynamical Middlefrequency Interferometric GW Observatory.

  19. Atmospheric Electric Field Measurements at 100 Hz and High Frequency Electric Phenomena

    NASA Astrophysics Data System (ADS)

    Conceição, Ricardo; Gonçalves da Silva, Hugo; Matthews, James; Bennett, Alec; Chubb, John

    2016-04-01

    Spectral response of Atmospheric Electric Potential Gradient (PG), symmetric to the Atmospheric Electric Field, gives important information about phenomena affecting these measurements with characteristic time-scales that appear in the spectra as specific periodicities. This is the case of urban pollution that has a clear weekly dependence and reveals itself on PG measurements by a ~7 day periodicity (Silva et al., 2014). While long-term time-scales (low frequencies) have been exhaustively explored in literature, short-term time-scales (high frequencies), above 1 Hz, have comparatively received much less attention (Anisimov et al., 1999). This is mainly because of the technical difficulties related with the storage of such a huge amount of data (for 100 Hz sampling two days of data uses a ~1 Gb file) and the response degradation of the field-meters at such frequencies. Nevertheless, important Electric Phenomena occurs for frequencies above 1 Hz that are worth pursuing, e.g. the Schumann Resonances have a signature of worldwide thunderstorm activity at frequencies that go from ~8 up to ~40 Hz. To that end the present work shows preliminary results on PG measurements at 100 Hz that took place on two clear-sky days (17th and 18th June 2015) on the South of Portugal, Évora (38.50° N, 7.91° W). The field-mill used is a JCI 131F installed in the University of Évora campus (at 2 m height) with a few trees and two buildings in its surroundings (~50 m away). This device was developed by John Chubb (Chubb, 2014) and manufactured by Chilworth (UK). It was calibrated in December 2013 and recent work by the author (who is honored in this study for his overwhelming contribution to atmospheric electricity) reveals basically a flat spectral response of the device up to frequencies of 100 Hz (Chubb, 2015). This makes this device suitable for the study of High Frequency Electric Phenomena. Anisimov, S.V., et al. (1999). On the generation and evolution of aeroelectric structures in the surface layer. J. Geophys. Res., 104(D12), 14359-14367. Chubb, J. (2014). The measurement of atmospheric electric fields using pole mounted electrostatic fieldmeters. Journal of Electrostatics 72, 295-300. Chubb, J. (2015). Limitations on the performance of 'field mill' fieldmeters with alternating electric fields. Journal of Electrostatics 78, 1-3. Silva, H.G. et al. (2014). Atmospheric electric field measurements in urban environment and the pollutant aerosol weekly dependence. Environment Research Letters, 9, 114025.

  20. Radar investigation of asteroids

    NASA Technical Reports Server (NTRS)

    Ostro, S. J.

    1983-01-01

    For 80 Sappho, 356 Liguria, 694 Ekard, and 2340 Hathor, data were taken simultaneously in the same sense of circular polarization as transmitted (SC) as well as in the opposite (OC) sense. Graphs show the average OC and SC radar echo power spectra soothed to a resolution of EFB Hz and plotted against Doppler frequency. Radar observations of the peculiar object 2201 Oljato reveal an unusual set of echo power spectra. The albedo and polarization ratio remain fairly constant but the bandwidths range from approximately 0.8 Hz to 1.4 Hz and the spectral shapes vary dramatically. Echo characteristics within any one date's approximately 2.5-hr observation period do not fluctuate very much. Laboratory measurements of the radar frequency electrical properties of particulate metal-plus-silicate mixtures can be combined with radar albedo estimates to constrain the bulk density and metal weight, fraction in a hypothetical asteroid regolith having the same particle size distribution as lab samples.

  1. Analysis of Flame Extinguishment and Height in Low Frequency Acoustically Excited Methane Jet Diffusion Flame

    NASA Astrophysics Data System (ADS)

    Zong, Ruowen; Kang, Ruxue; Liu, Chen; Zhang, Zhiyang; Zhi, Youran

    2018-01-01

    The exploration of microgravity conditions in space is increasing and existing fire extinguishing technology is often inadequate for fire safety in this special environment. As a result, improving the efficiency of portable extinguishers is of growing importance. In this work, a visual study of the effects on methane jet diffusion flames by low frequency sound waves is conducted to assess the extinguishing ability of sound waves. With a small-scale sound wave extinguishing bench, the extinguishing ability of certain frequencies of sound waves are identified, and the response of the flame height is observed and analyzed. Results show that the flame structure changes with disturbance due to low frequency sound waves of 60-100 Hz, and quenches at effective frequencies in the range of 60-90 Hz. In this range, 60 Hz is considered to be the quick extinguishing frequency, while 70-90 Hz is the stable extinguishing frequency range. For a fixed frequency, the flame height decreases with sound pressure level (SPL). The flame height exhibits the greatest sensitivity to the 60 Hz acoustic waves, and the least to the 100 Hz acoustic waves. The flame height decreases almost identically with disturbance by 70-90 Hz acoustic waves.

  2. Analysis of Flame Extinguishment and Height in Low Frequency Acoustically Excited Methane Jet Diffusion Flame

    NASA Astrophysics Data System (ADS)

    Zong, Ruowen; Kang, Ruxue; Liu, Chen; Zhang, Zhiyang; Zhi, Youran

    2018-05-01

    The exploration of microgravity conditions in space is increasing and existing fire extinguishing technology is often inadequate for fire safety in this special environment. As a result, improving the efficiency of portable extinguishers is of growing importance. In this work, a visual study of the effects on methane jet diffusion flames by low frequency sound waves is conducted to assess the extinguishing ability of sound waves. With a small-scale sound wave extinguishing bench, the extinguishing ability of certain frequencies of sound waves are identified, and the response of the flame height is observed and analyzed. Results show that the flame structure changes with disturbance due to low frequency sound waves of 60-100 Hz, and quenches at effective frequencies in the range of 60-90 Hz. In this range, 60 Hz is considered to be the quick extinguishing frequency, while 70-90 Hz is the stable extinguishing frequency range. For a fixed frequency, the flame height decreases with sound pressure level (SPL). The flame height exhibits the greatest sensitivity to the 60 Hz acoustic waves, and the least to the 100 Hz acoustic waves. The flame height decreases almost identically with disturbance by 70-90 Hz acoustic waves.

  3. High-frequency energy in singing and speech

    NASA Astrophysics Data System (ADS)

    Monson, Brian Bruce

    While human speech and the human voice generate acoustical energy up to (and beyond) 20 kHz, the energy above approximately 5 kHz has been largely neglected. Evidence is accruing that this high-frequency energy contains perceptual information relevant to speech and voice, including percepts of quality, localization, and intelligibility. The present research was an initial step in the long-range goal of characterizing high-frequency energy in singing voice and speech, with particular regard for its perceptual role and its potential for modification during voice and speech production. In this study, a database of high-fidelity recordings of talkers was created and used for a broad acoustical analysis and general characterization of high-frequency energy, as well as specific characterization of phoneme category, voice and speech intensity level, and mode of production (speech versus singing) by high-frequency energy content. Directionality of radiation of high-frequency energy from the mouth was also examined. The recordings were used for perceptual experiments wherein listeners were asked to discriminate between speech and voice samples that differed only in high-frequency energy content. Listeners were also subjected to gender discrimination tasks, mode-of-production discrimination tasks, and transcription tasks with samples of speech and singing that contained only high-frequency content. The combination of these experiments has revealed that (1) human listeners are able to detect very subtle level changes in high-frequency energy, and (2) human listeners are able to extract significant perceptual information from high-frequency energy.

  4. Effect of the voltage pulse frequency on the structure of TiO2 coatings grown by plasma electrolytic oxidation

    NASA Astrophysics Data System (ADS)

    Torres-Cerón, D. A.; Gordillo-Delgado, F.; Moya-Betancourt, S. N.

    2017-12-01

    Plasma Electrolytic Oxidation (PEO) is used to synthetize titanium dioxide (TiO2) ceramic coatings with the appropriate selection of an electrolyte. The dimension of the micro-cavities and the particle size at the surface can be controlled through the pulse frequency of the voltage that is applied between the electrodes. The change of surface morphology can increase the surface area-to-volume ratio. In this work, PEO of an ASME SB-265 titanium substrate (20×20×1mm) was made in a water solution containing 8g/L Na3PO4 and 0.4g/L NaOH. Hence, the coatings were fabricated using voltage pulses of 340V for 10 minutes with a 10% duty cycle and frequencies of 1000, 1500 and 2000Hz. According to the X-ray diffractograms of the obtained samples, the sintering process at 500°C during 1 hour generated Anatase titanium dioxide porous coatings. The grain size decreased approximately from 29nm for 1000 and 1500Hz pulse frequencies until 21nm for 2000Hz. On the other hand, from the micrographs of scanning electron microscopy was possible to see the uniform formation of the micro-cavities with the largest diameter, 900nm, for the lowest frequency value used in PEO.

  5. High-frequency electroacupuncture evidently reinforces hippocampal synaptic transmission in Alzheimer's disease rats

    PubMed Central

    Li, Wei; Kong, Li-hong; Wang, Hui; Shen, Feng; Wang, Ya-wen; Zhou, Hua; Sun, Guo-jie

    2016-01-01

    The frequency range of electroacupuncture in treatment of Alzheimer's disease in rats is commonly 2–5 Hz (low frequency) and 50–100 Hz (high frequency). We established a rat model of Alzheimer's disease by injecting β-amyloid 1–42 (Aβ1–42) into the bilateral hippocampal dentate gyrus to verify which frequency may be better suited in treatment. Electroacupuncture at 2 Hz or 50 Hz was used to stimulate Baihui (DU20) and Shenshu (BL23) acupoints. The water maze test and electrophysiological studies demonstrated that spatial memory ability was apparently improved, and the ranges of long-term potentiation and long-term depression were increased in Alzheimer's disease rats after electroacupuncture treatment. Moreover, the effects of electroacupuncture at 50 Hz were better than that at 2 Hz. These findings suggest that high-frequency electroacupuncture may enhance hippocampal synaptic transmission and potentially improve memory disorders in Alzheimer's disease rats. PMID:27335565

  6. Integrating the ECG power-line interference removal methods with rule-based system.

    PubMed

    Kumaravel, N; Senthil, A; Sridhar, K S; Nithiyanandam, N

    1995-01-01

    The power-line frequency interference in electrocardiographic signals is eliminated to enhance the signal characteristics for diagnosis. The power-line frequency normally varies +/- 1.5 Hz from its standard value of 50 Hz. In the present work, the performances of the linear FIR filter, Wave digital filter (WDF) and adaptive filter for the power-line frequency variations from 48.5 to 51.5 Hz in steps of 0.5 Hz are studied. The advantage of the LMS adaptive filter in the removal of power-line frequency interference even if the frequency of interference varies by +/- 1.5 Hz from its normal value of 50 Hz over other fixed frequency filters is very well justified. A novel method of integrating rule-based system approach with linear FIR filter and also with Wave digital filter are proposed. The performances of Rule-based FIR filter and Rule-based Wave digital filter are compared with the LMS adaptive filter.

  7. 47 CFR 87.173 - Frequencies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...

  8. 47 CFR 87.173 - Frequencies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...

  9. 47 CFR 87.173 - Frequencies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...

  10. 47 CFR 87.173 - Frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...

  11. 47 CFR 87.173 - Frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... traffic control. 325-435 kHz Q RLB Radiobeacons. 410.0 kHz F MA International direction-finding for use outside of United States. 457.0 kHz F MA Working frequency for aircraft on over-water flights. 500.0 kHz F MA International calling and distress frequency for ships and aircraft on over-water flights. 510-535...

  12. 47 CFR 95.857 - Emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... frequency as close to the edge of the authorized frequency segment as the transmitter is designed to be... power shall be 100 Hz for measuring emissions up to and including 250 kHz from the edge of the authorized frequency segment, and 10 kHz for measuring emissions more than 250 kHz from the edge of the...

  13. Development of Dielectric Material with Ceramic Matrix Composite (CMC) Produced from Kaolinite and CaCu{sub 3}Ti{sub 4}O{sub 12} (CCTO)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yin, Wong Swee; Hassan, Jumiah; Hashim, Mansor

    Ceramic matrix composites (CMC) combine reinforcing ceramic phases, CaCu{sub 3}Ti{sub 4}O{sub 12} (CCTO) with a ceramic matrix, kaolinite to create materials with new and superior properties. 10% and 20% CCTO were prepared by using a conventional solid state reaction method. CMC samples were pre-sintered at 800 deg. C and sintered at 1000 deg. C. The dielectric properties of samples were measured using HP 4192A LF Impedance Analyzer. Microstructures of the samples were observed using an optical microscope. XRD was used to determine the crystalline structure of the samples. The AFM showed the morphology of the samples. The results showed thatmore » the dielectric constant and dielectric loss factor of both samples are frequency dependent. At 10 Hz, the dielectric constant is 10{sup 11} for both samples. The CMC samples were independent with temperature with low dielectric constant in the frequency range of 10{sup 4}-10{sup 6} Hz. Since the CMC samples consist of different amount of kaolinite, so each sample exhibit different defect mechanism. Different reaction may occur for different composition of material. The effects of processing conditions on the microstructure and electrical properties of CMC are also discussed.« less

  14. Gerbil middle-ear sound transmission from 100 Hz to 60 kHz1

    PubMed Central

    Ravicz, Michael E.; Cooper, Nigel P.; Rosowski, John J.

    2008-01-01

    Middle-ear sound transmission was evaluated as the middle-ear transfer admittance HMY (the ratio of stapes velocity to ear-canal sound pressure near the umbo) in gerbils during closed-field sound stimulation at frequencies from 0.1 to 60 kHz, a range that spans the gerbil’s audiometric range. Similar measurements were performed in two laboratories. The HMY magnitude (a) increased with frequency below 1 kHz, (b) remained approximately constant with frequency from 5 to 35 kHz, and (c) decreased substantially from 35 to 50 kHz. The HMY phase increased linearly with frequency from 5 to 35 kHz, consistent with a 20–29 μs delay, and flattened at higher frequencies. Measurements from different directions showed that stapes motion is predominantly pistonlike except in a narrow frequency band around 10 kHz. Cochlear input impedance was estimated from HMY and previously-measured cochlear sound pressure. Results do not support the idea that the middle ear is a lossless matched transmission line. Results support the ideas that (1) middle-ear transmission is consistent with a mechanical transmission line or multiresonant network between 5 and 35 kHz and decreases at higher frequencies, (2) stapes motion is pistonlike over most of the gerbil auditory range, and (3) middle-ear transmission properties are a determinant of the audiogram. PMID:18646983

  15. Low-frequency dynamic response of the bismuth strontium ferrite (Bi,Sr)FeO3- x

    NASA Astrophysics Data System (ADS)

    Pronin, A. A.; Torgashev, V. I.; Bush, A. A.; Gorshunov, B. P.; Volkov, A. A.; Prokhorov, A. S.

    2009-03-01

    Broad-range measurements of the dynamic response of polycrystalline samples of the (Bi,Sr)FeO3- x perovskite-like solid solution are performed over a frequency range from 10 Hz to 1 GHz at temperatures of 100-300 K for the first time. The colossal dielectric constant effect and the influence of electric contacts on the results of measurements are considered. It is shown that the frequency dependences of the permittivity and dynamic conductivity of (Bi,Sr)FeO3- x samples can be described within the universal dielectric response model.

  16. Note: An approach to measurement of low frequency oscillation amplitude of discharge current of in-orbit Hall thruster.

    PubMed

    Han, Liang; Ding, Yongjie; Wei, Liqiu; Yu, Daren

    2014-06-01

    This paper provides a method to measure the amplitude of low frequency oscillation under the on-track working condition, and realizes the sampling by means of adding the circuit design of sampling, low pass filtering by 3 dB at 48.2 kHz, detection and integrating in the filtering unit. The experimental results prove that the measuring device of merely 0.8 g can quantitatively reflect the amplitude of low frequency oscillation in Hall thruster and the maximum deviation of experiment data and theory data is 10% FS.

  17. Thermal emittance enhancement of graphite-copper composites for high temperature space based radiators

    NASA Technical Reports Server (NTRS)

    Rutledge, Sharon K.; Forkapa, Mark J.; Cooper, Jill M.

    1991-01-01

    Graphite-copper composites are candidate materials for space based radiators. The thermal emittance of this material, however, is a factor of two lower than the desired emittance for these systems of greater than or equal to 0.85. Arc texturing was investigated as a surface modification technique for enhancing the emittance of the composite. Since the outer surface of the composite is copper, and samples of the composite could not be readily obtained for testing, copper was used for optimization testing. Samples were exposed to various frequencies and currents of arcs during texturing. Emittances near the desired goal were achieved at frequencies less than 500 Hz. Arc current did not appear to play a major role under 15 amps. Particulate carbon was observed on the surface, and was easily removed by vibration and handling. In order to determine morphology adherence, ultrasonic cleaning was used to remove the loosely adherent material. This reduced the emittance significantly. Emittance was found to increase with increasing frequency for the cleaned samples up to 500 Hz. The highest emittance achieved on these samples over the temperature range of interest was 0.5 to 0.6, which is approximately a factor of 25 increase over the untextured copper emittance.

  18. Application of a TiO2 nanocomposite in earplugs, a case study of noise reduction.

    PubMed

    Ibrahimi Ghavamabadi, Leila; Fouladi Dehaghi, Behzad; Hesampour, Morteza; Ahmadi Angali, Kambiz

    2018-03-13

    Use of hearing protection devices (HPDs) has become necessary when other control measures cannot reduce noise to a safe and standard level. In most countries, more effective hearing protection devices are in demand. The aim of this study was to examine the effects of titanium dioxide (TiO 2 ) nanoparticles on noise reduction efficiency in a polyvinyl chloride (PVC) earplug. An S-60 type PVC polymer as main matrix and TiO 2 with 30 nm size were used. PVC/TiO 2 nanocomposite was mixed at a temperature of 160 °C and 40 rounds per minute (rpm) and the samples were prepared with 0, 0.2 and 0.5 wt% of TiO 2 nanoparticle concentrations. Earplug samples with PVC/TiO 2 (0.2, 0.5 wt%) nanoparticles, when compared with raw earplugs, showed almost equal noise attenuation at low frequencies (500- 125 Hz). However, at high frequencies (2-8 kHz), the power of noise reduction of earplugs containing TiO 2 nanoparticles was significantly increased. The results of the present study showed that samples containing nanoparticles of TiO 2 had more noticeable noise reduction abilities at higher frequencies in comparison with samples without the nanoparticles.

  19. Electrical properties of lunar soil dependence on frequency, temperature and moisture.

    NASA Technical Reports Server (NTRS)

    Strangway, D. W.; Chapman, W. B.; Olhoeft, G. R.; Carnes, J.

    1972-01-01

    It was found that the dielectric constant and loss tangent of lunar soil samples in the range from 100 Hz to 1 MHz are not strongly dependent on frequency provided care is taken to avoid exposure of the sample to atmospheric air containing moisture. The loss tangent value obtained is lower by nearly a factor 10 than any previously reported value. The measurement data imply that the surface layers of the moon are probably extremely transparent to radiowaves.

  20. Scanning hall probe microscopy (SHPM) using quartz crystal AFM feedback.

    PubMed

    Dede, M; Urkmen, K; Girişen, O; Atabak, M; Oral, A; Farrer, I; Ritchie, D

    2008-02-01

    Scanning Hall Probe Microscopy (SHPM) is a quantitative and non-invasive technique for imaging localized surface magnetic field fluctuations such as ferromagnetic domains with high spatial and magnetic field resolution of approximately 50 nm and 7 mG/Hz(1/2) at room temperature. In the SHPM technique, scanning tunneling microscope (STM) or atomic force microscope (AFM) feedback is used to keep the Hall sensor in close proximity of the sample surface. However, STM tracking SHPM requires conductive samples; therefore the insulating substrates have to be coated with a thin layer of gold. This constraint can be eliminated with the AFM feedback using sophisticated Hall probes that are integrated with AFM cantilevers. However it is very difficult to micro fabricate these sensors. In this work, we have eliminated the difficulty in the cantilever-Hall probe integration process, just by gluing a Hall Probe chip to a quartz crystal tuning fork force sensor. The Hall sensor chip is simply glued at the end of a 32.768 kHz or 100 kHz Quartz crystal, which is used as force sensor. An LT-SHPM system is used to scan the samples. The sensor assembly is dithered at the resonance frequency using a digital Phase Locked Loop circuit and frequency shifts are used for AFM tracking. SHPM electronics is modified to detect AFM topography and the frequency shift, along with the magnetic field image. Magnetic domains and topography of an Iron Garnet thin film crystal, NdFeB demagnetised magnet and hard disk samples are presented at room temperature. The performance is found to be comparable with the SHPM using STM feedback.

  1. Whistle description of Irrawaddy dolphins (Orcaella brevirostris) in Bay of Brunei, Sarawak, Malaysia.

    PubMed

    Muhamad, Hairul Masrini; Xu, Xiaomei; Zhang, Xuelei; Jaaman, Saifullah Arifin; Muda, Azmi Marzuki

    2018-05-01

    Studies of Irrawaddy dolphins' acoustics assist in understanding the behaviour of the species and thereby conservation of this species. Whistle signals emitted by Irrawaddy dolphin within the Bay of Brunei in Malaysian waters were characterized. A total of 199 whistles were analysed from seven sightings between January and April 2016. Six types of whistles contours named constant, upsweep, downsweep, concave, convex, and sine were detected when the dolphins engaged in traveling, foraging, and socializing activities. The whistle durations ranged between 0.06 and 3.86 s. The minimum frequency recorded was 443 Hz [Mean = 6000 Hz, standard deviation (SD) = 2320 Hz] and the maximum frequency recorded was 16 071 Hz (Mean = 7139 Hz, SD = 2522 Hz). The mean frequency range (F.R.) for the whistles was 1148 Hz (Minimum F.R. = 0 Hz, Maximum F.R. = 4446 Hz; SD = 876 Hz). Whistles in the Bay of Brunei were compared with population recorded from the waters of Matang and Kalimantan. The comparisons showed differences in whistle duration, minimum frequency, start frequency, and number of inflection point. Variation in whistle occurrence and frequency may be associated with surface behaviour, ambient noise, and recording limitation. This will be an important element when planning a monitoring program.

  2. Modulation of electrocortical brain activity by attention in individuals with and without tinnitus.

    PubMed

    Paul, Brandon T; Bruce, Ian C; Bosnyak, Daniel J; Thompson, David C; Roberts, Larry E

    2014-01-01

    Age and hearing-level matched tinnitus and control groups were presented with a 40 Hz AM sound using a carrier frequency of either 5 kHz (in the tinnitus frequency region of the tinnitus subjects) or 500 Hz (below this region). On attended blocks subjects pressed a button after each sound indicating whether a single 40 Hz AM pulse of variable increased amplitude (target, probability 0.67) had or had not occurred. On passive blocks subjects rested and ignored the sounds. The amplitude of the 40 Hz auditory steady-state response (ASSR) localizing to primary auditory cortex (A1) increased with attention in control groups probed at 500 Hz and 5 kHz and in the tinnitus group probed at 500 Hz, but not in the tinnitus group probed at 5 kHz (128 channel EEG). N1 amplitude (this response localizing to nonprimary cortex, A2) increased with attention at both sound frequencies in controls but at neither frequency in tinnitus. We suggest that tinnitus-related neural activity occurring in the 5 kHz but not the 500 Hz region of tonotopic A1 disrupted attentional modulation of the 5 kHz ASSR in tinnitus subjects, while tinnitus-related activity in A1 distributing nontonotopically in A2 impaired modulation of N1 at both sound frequencies.

  3. Modulation of Electrocortical Brain Activity by Attention in Individuals with and without Tinnitus

    PubMed Central

    Paul, Brandon T.; Bruce, Ian C.; Bosnyak, Daniel J.; Thompson, David C.; Roberts, Larry E.

    2014-01-01

    Age and hearing-level matched tinnitus and control groups were presented with a 40 Hz AM sound using a carrier frequency of either 5 kHz (in the tinnitus frequency region of the tinnitus subjects) or 500 Hz (below this region). On attended blocks subjects pressed a button after each sound indicating whether a single 40 Hz AM pulse of variable increased amplitude (target, probability 0.67) had or had not occurred. On passive blocks subjects rested and ignored the sounds. The amplitude of the 40 Hz auditory steady-state response (ASSR) localizing to primary auditory cortex (A1) increased with attention in control groups probed at 500 Hz and 5 kHz and in the tinnitus group probed at 500 Hz, but not in the tinnitus group probed at 5 kHz (128 channel EEG). N1 amplitude (this response localizing to nonprimary cortex, A2) increased with attention at both sound frequencies in controls but at neither frequency in tinnitus. We suggest that tinnitus-related neural activity occurring in the 5 kHz but not the 500 Hz region of tonotopic A1 disrupted attentional modulation of the 5 kHz ASSR in tinnitus subjects, while tinnitus-related activity in A1 distributing nontonotopically in A2 impaired modulation of N1 at both sound frequencies. PMID:25024849

  4. Analysis of long term heart rate variability: methods, 1/f scaling and implications

    NASA Technical Reports Server (NTRS)

    Saul, J. P.; Albrecht, P.; Berger, R. D.; Cohen, R. J.

    1988-01-01

    The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.

  5. Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William, R. V.; Marikani, A., E-mail: amari@mepcoeng.ac.in; Madhavan, D.

    Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO{sub 3} nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO{sub 3} nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO{sub 3} nano-wire show a frequency dependent propertymore » and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm{sup 2} at the frequency 4 kHz. The coercivity of BiFeO{sub 3} nano wire changes with variation of frequency from 1 kHz to 4 kHz.« less

  6. An Observation of Repeating Events at local asperities during a Laboratory Stick-slip Experiment of a Saw-cut Cylindrical Lucite Sample

    NASA Astrophysics Data System (ADS)

    Gu, C.; Mighani, S.; Prieto, G. A.; Mok, U.; Evans, J. B.; Hager, B. H.; Toksoz, M. N.

    2017-12-01

    Repeating earthquakes have been found in subduction zones and interpreted as repeated ruptures of small local asperities. Repeating earthquakes have also been found in oil/gas fields, interpreted as the reactivation of pre-existing faults due to fluid injection/extraction. To mimic the fault rupture of a fault with local asperities, we designed a "stick-slip" experiment using a saw-cut cylindrical Lucite sample, which had sharp localized ridges parallel to the strike of the fault plane. The sample was subjected to conventional triaxial loading with a constant confining pressure of 10 MPa. The axial load was then increased to 6 MPa at a constant rate of 0.12 MPa/sec until the sliding occurred along the fault plane. Ultrasonic acoustic emissions (AEs) were monitored with eight PZT sensors. Two cycles of AEs were detected with the occurrence rate that decreased from the beginning to the end of each cycle, while the relative magnitudes increased. Correlation analysis indicated that these AEs were clustered into two groups - those with frequency content between 200-300kHz and a second group with frequency content between 10-50kHz. The locations of the high-frequency events, with almost identical waveforms, show that these events are from the sharp localized ridges on the saw-cut plane. The locations of the low-frequency events show an approaching process to the high-frequency events for each cycle. In this single experiment, there was a correlation of the proximity of the low-frequency events with the subsequent triggering of large high-frequency repeating events.

  7. Using high sampling rate (10/20 Hz) altimeter data for the observation of coastal surface currents: A case study over the northwestern Mediterranean Sea

    NASA Astrophysics Data System (ADS)

    Birol, Florence; Delebecque, Caroline

    2014-01-01

    Satellite altimetry, measuring sea surface heights (SSHs), has unique capabilities to provide information about the ocean dynamics. In this paper, the skill of the original full rate (10/20 Hz) measurements, relative to conventional 1-Hz data, is evaluated in the context of coastal studies in the Northwestern Mediterranean Sea. The performance and the question of the measurement noise are quantified through a comparison with different tide gauge sea level time series. By applying a specific processing, closer than 30 km to the land, the number of valid data is higher for the 10/20-Hz than for the 1-Hz observations: + 4.5% for T/P, + 10.3 for Jason-1 and + 13% for Jason-2. By filtering higher sampling rate measurements (using a 30-km cut-off low-pass Lanczos filter), we can obtain the same level of sea level accuracy as we would using the classical 1-Hz altimeter data. The gain in near-shore data results in a better observation of the Liguro-Provençal-Catalan Current. The seasonal evolution of the currents derived from 20-Hz data is globally consistent with patterns derived from the corresponding 1-Hz observations. But the use of higher frequency altimeter measurements allows us to observe the variability of the regional flow closer to the coast (~ 10-15 km from land).

  8. 14 CFR 171.259 - Performance requirements: General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... V (±0.2 V).* AC line frequency (60 Hz), 57 Hz to 63 Hz (±0.2 Hz).* DC voltage (48 V), 44 V to 52 V (±0.5 V).* *Note: Where discrete values of the above frequency or voltages are specified for testing... runway localizer and glide path transmitter frequencies of an ISMLS must be in accordance with the...

  9. Structural and AC loss study for pure and doped MgB{sub 2} superconductor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansdah, J. S.; Sarun, P. M., E-mail: sarun.res@gmail.com

    2015-06-24

    Superconducting polycrystalline bulk MgB{sub 2} samples doped with n-C, n-Y{sub 2}O{sub 3} and n-Ho{sub 2}O{sub 3} were prepared by powder-in-sealed (PIST) method. XRD measurement shows the influence of dopants on phase and lattice parameters of samples. The ac susceptibility measurement reveals ac loss and activation energy of the samples. Nano-C doped sample shows less ac loss in all frequency (208 Hz – 999 Hz) among the doped samples; whereas n-Ho{sub 2}O{sub 3} doped sample shows highest ac loss. The activation energy is high for rare earth (n-Y{sub 2}O{sub 3} and n-Ho{sub 2}O{sub 3}) doped samples as compare to n-C doped samples whichmore » reveals the enhancement in flux-pinning properties of these materials.« less

  10. Development of a system for measurement and analysis of tremor using a three-axis accelerometer.

    PubMed

    Mamorita, N; Iizuka, T; Takeuchi, A; Shirataka, M; Ikeda, N

    2009-01-01

    The aim of the study was to develop a low-cost and compact system for analysis of tremor using a three-axis accelerometer (the Wii Remote (Nintendo)). To analyze tremor, we hypothesized that the influence of gravitational acceleration should be separated from that of movement. This hypothesis was tested experimentally and we also attempted to record and analyze tremor using our system in a clinical ward. A system for tremor measurement and analysis was developed using the three-axis accelerometer built into the Wii Remote. The frequency and amplitude of mechanical oscillation were calculated using methods for frequency analysis of the axis of largest variance and an estimation of tremor amplitude. The system consists of a program for measurement and analysis of Wii Remote acceleration (Tremor Analyzer), a Wii Remote, a Bluetooth USB adapter and a Web camera. The Tremor Analyzer has a GUI (graphical user interface) that is divided into five seg- ments. The sampling period of the analyzer is 30 msec. To confirm the hypothesis, mechanical oscillations were fed to the Wii Remote. The peak frequency of the power spectrum and the frequency of the oscillation generator were in good agreement, except at 1 Hz (0.01 G) and 2 Hz (0.02 G). With a change in the sum of squares of the three axes from 1.0 to 1.8 (G), the estimated and generated amplitude (0.3 cm) were in close agreement. This system using a Wii Remote is capable of analyzing frequency and estimated amplitude of tremor between 3 Hz and 15 Hz.

  11. Development of Geometry Normalized Electromagnetic System (GNES) instrument for metal defect detection

    NASA Astrophysics Data System (ADS)

    Zakaria, Zakaria; Surbakti, Muhammad Syukri; Syahreza, Saumi; Mat Jafri, Mohd. Zubir; Tan, Kok Chooi

    2017-10-01

    It has been already made, calibrated and tested a geometry normalized electromagnetic system (GNES) for metal defect examination. The GNES has an automatic data acquisition system which supporting the efficiency and accuracy of the measurement. The data will be displayed on the computer monitor as a graphic display then saved automatically in the Microsoft Excel format. The transmitter will transmit the frequency pair (FP) signals i.e. 112.5 Hz and 337.5 Hz; 112.5 Hz and 1012.5 Hz; 112.5 Hz and 3037.5 Hz; 337.5 Hz and 1012.5 Hz; 337.5 Hz and 3037.5 Hz. Simultaneous transmissions of two electromagnetic waves without distortions by the transmitter will induce an eddy current in the metal. This current, in turn, will produce secondary electromagnetic fields which are measured by the receiver together with the primary fields. Measurement of percent change of a vertical component of the fields will give the percent response caused by the metal or the defect. The response examinations were performed by the models with various type of defect for the master curves. The materials of samples as a plate were using Aluminum, Brass, and Copper. The more of the defects is the more reduction of the eddy current response. The defect contrasts were tended to decrease when the more depth of the defect position. The magnitude and phase of the eddy currents will affect the loading on the coil thus its impedance. The defect must interrupt the surface eddy current flow to be detected. Defect lying parallel to the current path will not cause any significant interruption and may not be detected. The main factors which affect the eddy current response are metal conductivity, permeability, frequency, and geometry.

  12. Biomechanics and Biotensegrity: Study Method and Frequency Response of the Simplex and 3-bar-SVD Tensegrity Configurations

    NASA Astrophysics Data System (ADS)

    Castro Arenas, C.; Ghersi, I.; Miralles, M. T.

    2016-04-01

    The purpose of this work is to study the frequency response of 3D tensegrity structures. These are structures that have been used, since the 80’s, to model biological systems of different scales. This fact led to the origin of the field of biotensegrity, which includes biomechanics as a natural field of application. In this work: a) A simple method for the analysis of frequency response of different nodes in 3D tensegrity structures was set up and tuned. This method is based on a video-analysis algorithm, which was applied to the structures, as they were vibrated along their axis of symmetry, at frequencies from 1 Hz to 60 Hz. b) Frequency-response analyses were performed, for the simplest 3D structure, the Simplex module, as well as for two towers, formed by stacking two and three Simplex modules, respectively. Resonant frequencies were detected for the Simplex module at (19.2±0.1) Hz and (50.2±0.1) Hz (the latter being an average of frequencies between homologous nodes). For the towers with two and three modules, each selected node presented a characteristic frequency response, modulated by their spatial placement in each model. Resonances for the two-stage tower were found at: (12±0.1) Hz; (16.2±0.1) Hz; (29.4±0.1) Hz and (37.2±0.1) Hz. For the tower with three Simplex modules, the main resonant frequencies were found at (12.0±0.1) Hz and (21.0±0.1) Hz. Results show that the proposed method is adequate for the study (2D) of any 3D tensegrity structure, with the potential of being generalized to the study of oscillations in three dimensions. A growing complexity and variability in the frequency response of the nodes was observed, as modules were added to the structures. These findings were compared to those found in the available literature.

  13. Heat treatment effects on dielectric properties of SRFe{sub 12}O{sub 19} hexaferrite prepared by an SHS route

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panchal, Nital R.; Jotania, Rajshree B., E-mail: natal_panchal@yahoo.co.in, E-mail: rbjotania@gmail.com

    2011-07-01

    The M-type Strontium Hexaferrite SRFe{sub 12}O{sub 19} particles were prepared by a Self propagating High temperature Synthesis (SHS) route. Precursors were heated under two different conditions: microwave heating for 30 minutes and sintered at 950 deg C for 4 hrs. The dielectric properties: dielectric constant ({epsilon}{sup '}), dielectric loss (tan {delta} ) and ac conductivity ({sigma}{sub ac}) were measured at room temperature in the frequency range from 100 Hz to 2 MHz. The samples present a non-linear behavior for the dielectric constant at 1 kHz, 100 kHz and 2 MHz. The dielectric properties of prepared Strontium Hexaferrite samples were discussedmore » in view of applications as a material for microwave devices, permanent magnets and high density magnetic recording media. (author)« less

  14. Regional Lg attenuation for the continental United States

    USGS Publications Warehouse

    Benz, H.M.; Frankel, A.; Boore, D.M.

    1997-01-01

    Measurements of the Fourier amplitude spectra of Lg phases recorded at high frequency (0.5 to 14.0 Hz) by broadband seismic stations are used to determine regional attenuation relationships for southern California, the Basin and Range Province, the central United States, and the northeastern United States and southeastern Canada. Fourier spectral amplitudes were measured every quarter octave from Lg phases windowed between 3.0 and 3.7 km sec-1 and recorded in the distance range of 150 to 1000 km. Attenuation at each frequency is determined by assuming a geometrical spreading exponent of 0.5 and inverting for Q and source and receiver terms. Both southern California and the Basin and Range Province are well described by low Lg Q and frequency-dependent attenuation. Lg spectral amplitudes in southern California are fit at low frequencies (0.625 to 0.875 Hz) by a constant Lg Q of 224 and by a frequency-dependent Lg Q function Q = 187-7+7 f0.55(??0.03) in the frequency band 1.0 to 7.0 Hz. The Basin and Range Province is characterized by a constant Lg Q of 192 for frequencies of 0.5 to 0.875 Hz and by the frequency-dependent Lg Q function Q = 235-11+11 f0.56(??0.04) in the frequency band 1.0 to 5.0 Hz. A change in frequency dependence above 5.0 Hz is possible due to contamination of the Lg window by Pn and Sn phases. Lg spectral amplitudes in the central United States are fit by a mean frequency-independent Lg Q of 1291 for frequencies of 1.5 to 7.0 Hz, while a frequency-dependent Lg Q of Q = 1052-83+91(f/1.5)0.22(??0.06) fits the Lg spectral amplitudes for the northeastern United States and southeastern Canada over the passband 1.5 to 14.0 Hz. Attenuation measurements for these areas were restricted to frequencies >1.5 Hz due to larger microseismic noise levels at the lower frequencies.

  15. Frequency difference limens at high frequencies: evidence for a transition from a temporal to a place code.

    PubMed

    Moore, Brian C J; Ernst, Stephan M A

    2012-09-01

    It is commonly believed that difference limens for frequency (DLFs) for pure tones depend on a temporal mechanism (phase locking) for frequencies up to 4-5 kHz and a place mechanism at higher frequencies. The DLFs predicted from a place mechanism, expressed as a proportion of center frequency (Δf/f), should be approximately invariant with frequency at medium to high frequencies. If there is a transition from a temporal to a place mechanism, Δf/f should increase with increasing center frequency until the transition occurs, and then reach a plateau. Published data do not show such an effect. In this study, DLFs were measured for center frequencies from 2 to 14 kHz, using earphones designed to produce a flat response at the eardrum. The level of every tone was varied over a range of ±4 dB, to reduce loudness cues. The value of Δf/f increased progressively from 2 to 8 kHz, but did not change significantly for frequencies from 8 to 14 kHz. The results are consistent with the idea that there is a transition from a temporal to a place mechanism at about 8 kHz, rather than at 4-5 kHz, as is commonly assumed.

  16. The impact of the microphone position on the frequency analysis of snoring sounds.

    PubMed

    Herzog, Michael; Kühnel, Thomas; Bremert, Thomas; Herzog, Beatrice; Hosemann, Werner; Kaftan, Holger

    2009-08-01

    Frequency analysis of snoring sounds has been reported as a diagnostic tool to differentiate between different sources of snoring. Several studies have been published presenting diverging results of the frequency analyses of snoring sounds. Depending on the position of the used microphones, the results of the frequency analysis of snoring sounds vary. The present study investigated the influence of different microphone positions on the outcome of the frequency analysis of snoring sounds. Nocturnal snoring was recorded simultaneously at six positions (air-coupled: 30 cm middle, 100 cm middle, 30 cm lateral to both sides of the patients' head; body contact: neck and parasternal) in five patients. The used microphones had a flat frequency response and a similar frequency range (10/40 Hz-18 kHz). Frequency analysis was performed by fast Fourier transformation and frequency bands as well as peak intensities (Peaks 1-5) were detected. Air-coupled microphones presented a wider frequency range (60 Hz-10 kHz) compared to contact microphones. The contact microphone at cervical position presented a cut off at frequencies above 300 Hz, whereas the contact microphone at parasternal position revealed a cut off above 100 Hz. On an exemplary base, the study demonstrates that frequencies above 1,000 Hz do appear in complex snoring patterns, and it is emphasised that high frequencies are imported for the interpretation of snoring sounds with respect to the identification of the source of snoring. Contact microphones might be used in screening devices, but for a natural analysis of snoring sounds the use of air-coupled microphones is indispensable.

  17. Dynamic mechanical analysis of multi-walled carbon nanotube/HDPE composites.

    PubMed

    Kanagaraj, S; Guedes, R M; Oliveira, Mónica S A; Simões, José A O

    2008-08-01

    Since the discovery of carbon nanotubes (CNTs), their remarkable properties make them ideal candidates to reinforce in advanced composites. In this attempt, an enhancement of mechanical properties of high density polyethylene (HDPE) by adding 1 wt% of CNTs is studied using Dynamic mechanical and Thermal analyzer (DMTA). The chemically treated and functionalized CNTs were homogeneously dispersed with HDPE and the test samples were made using injection molding machine. Using DMTA, storage modulus (E'), loss modulus (E") and damping factor (tan delta) of the sample under oscillating load were studied as a function of frequency of oscillation and temperatures. The storage modulus decreases with an increase of temperature and increases by adding CNTs in the composites where the reinforcing effect of CNT is confirmed. It is concluded that the large scale polymer relaxations in the composites are effectively restrained by the presence of CNTs and thus the mechanical properties of nanocomposites increase. The transition frequency of loss modulus is observed at 1 Hz. The loss modulus decreases with an increase of temperature at below 1 Hz but opposite trend was observed at above 1 Hz. The shift factor could be predicted from Williams-Landel-Ferry (WLF) model which has good agreement with experimental results.

  18. Effect of radio frequency waves of electromagnetic field on the tubulin.

    PubMed

    Taghi, Mousavi; Gholamhosein, Riazi; Saeed, Rezayi-Zarchi

    2013-09-01

    Microtubules (MTs) are macromolecular structures consisting of tubulin heterodimers and present in almost every eukaryotic cell. MTs fulfill all conditions for generation of electromagnetic field and are electrically polar due to the electrical polarity of a tubulin heterodimer. The calculated static electric dipole moment of about 1000 Debye makes them capable of being aligned parallel to the applied electromagnetic field direction. In the present study, the tubulin heterodimers were extracted and purified from the rat brains. MTs were obtained by polymerization in vitro. Samples of microtubules were adsorbed in the absence and in the presence of electromagnetic fields with radio frequency of 900 Hz. Our results demonstrate the effect of electromagnetic field with 900 Hz frequency to change the structure of MTs. In this paper, a related patent was used that will help to better understand the studied subject.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vecchio, Alberto; Wickham, Elizabeth D.L.

    The Laser Interferometer Space Antenna (LISA) is expected to provide the largest observational sample of binary systems of faint subsolar mass compact objects, in particular, white-dwarfs, whose radiation is monochromatic over most of the LISA observational window. Current astrophysical estimates suggest that the instrument will be able to resolve {approx}10{sup 4} such systems, with a large fraction of them at frequencies > or approx. 3 mHz, where the wavelength of gravitational waves becomes comparable to or shorter than the LISA armlength. This affects the structure of the so-called LISA transfer function which cannot be treated as constant in this frequencymore » range: it introduces characteristic phase and amplitude modulations that depend on the source location in the sky and the emission frequency. Here we investigate the effect of the LISA transfer function on detection and parameter estimation for monochromatic sources. For signal detection we show that filters constructed by approximating the transfer function as a constant (long-wavelength approximation) introduce a negligible loss of signal-to-noise ratio--the fitting factor always exceeds 0.97--for f{<=}10 mHz, therefore in a frequency range where one would actually expect the approximation to fail. For parameter estimation, we conclude that in the range 3 mHz < or approx. f < or approx. 30 mHz the errors associated with parameter measurements differ from {approx_equal}5% up to a factor {approx}10 (depending on the actual source parameters and emission frequency) with respect to those computed using the long-wavelength approximation.« less

  20. Evidence for differential modulation of primary and nonprimary auditory cortex by forward masking in tinnitus.

    PubMed

    Roberts, Larry E; Bosnyak, Daniel J; Bruce, Ian C; Gander, Phillip E; Paul, Brandon T

    2015-09-01

    It has been proposed that tinnitus is generated by aberrant neural activity that develops among neurons in tonotopic of regions of primary auditory cortex (A1) affected by hearing loss, which is also the frequency region where tinnitus percepts localize (Eggermont and Roberts 2004; Roberts et al., 2010, 2013). These models suggest (1) that differences between tinnitus and control groups of similar age and audiometric function should depend on whether A1 is probed in tinnitus frequency region (TFR) or below it, and (2) that brain responses evoked from A1 should track changes in the tinnitus percept when residual inhibition (RI) is induced by forward masking. We tested these predictions by measuring (128-channel EEG) the sound-evoked 40-Hz auditory steady-state response (ASSR) known to localize tonotopically to neural sources in A1. For comparison the N1 transient response localizing to distributed neural sources in nonprimary cortex (A2) was also studied. When tested under baseline conditions where tinnitus subjects would have heard their tinnitus, ASSR responses were larger in a tinnitus group than in controls when evoked by 500 Hz probes while the reverse was true for tinnitus and control groups tested with 5 kHz probes, confirming frequency-dependent group differences in this measure. On subsequent trials where RI was induced by masking (narrow band noise centered at 5 kHz), ASSR amplitude increased in the tinnitus group probed at 5 kHz but not in the tinnitus group probed at 500 Hz. When collapsed into a single sample tinnitus subjects reporting comparatively greater RI depth and duration showed comparatively larger ASSR increases after masking regardless of probe frequency. Effects of masking on ASSR amplitude in the control groups were completely reversed from those in the tinnitus groups, with no change seen to 5 kHz probes but ASSR increases to 500 Hz probes even though the masking sound contained no energy at 500 Hz (an "off-frequency" masking effect). In contrast to these findings for the ASSR, N1 amplitude was larger in tinnitus than control groups at both probe frequencies under baseline conditions, decreased after masking in all conditions, and did not relate to RI. These results suggest that aberrant neural activity occurring in the TFR of A1 underlies tinnitus and its modulation during RI. They indicate further that while neural changes occur in A2 in tinnitus, these changes do not reflect the tinnitus percept. Models for tinnitus and forward masking are described that integrate these findings within a common framework. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Occupational noise exposure and age correction: the problem of selection bias.

    PubMed

    Dobie, Robert A

    2009-12-01

    Selection bias often invalidates conclusions about populations based on clinical convenience samples. A recent paper in this journal makes two surprising assertions about noise-induced permanent threshold shift (NIPTS): first, that there is more NIPTS at 2 kHz than at higher frequencies; second, that NIPTS declines with advancing age. Neither assertion can be supported with the data presented, which were obtained from a clinical sample; both are consistent with the hypothesis that people who choose to attend an audiology clinic have worse hearing, especially at 2 kHz, than people of the same age and gender who choose not to attend.

  2. High-frequency viscoelastic shear properties of vocal fold tissues: implications for vocal fold tissue engineering.

    PubMed

    Teller, Sean S; Farran, Alexandra J E; Xiao, Longxi; Jiao, Tong; Duncan, Randall L; Clifton, Rodney J; Jia, Xinqiao

    2012-10-01

    The biomechanical function of the vocal folds (VFs) depends on their viscoelastic properties. Many conditions can lead to VF scarring that compromises voice function and quality. To identify candidate replacement materials, the structure, composition, and mechanical properties of native tissues need to be understood at phonation frequencies. Previously, the authors developed the torsional wave experiment (TWE), a stress-wave-based experiment to determine the linear viscoelastic shear properties of small, soft samples. Here, the viscoelastic properties of porcine and human VFs were measured over a frequency range of 10-200 Hz. The TWE utilizes resonance phenomena to determine viscoelastic properties; therefore, the specimen test frequency is determined by the sample size and material properties. Viscoelastic moduli are reported at resonance frequencies. Structure and composition of the tissues were determined by histology and immunochemistry. Porcine data from the TWE are separated into two groups: a young group, consisting of fetal and newborn pigs, and an adult group, consisting of 6-9-month olds and 2+-year olds. Adult tissues had an average storage modulus of 2309±1394 Pa and a loss tangent of 0.38±0.10 at frequencies of 36-200 Hz. The VFs of young pigs were significantly more compliant, with a storage modulus of 394±142 Pa and a loss tangent of 0.40±0.14 between 14 and 30 Hz. No gender dependence was observed. Histological staining showed that adult porcine tissues had a more organized, layered structure than the fetal tissues, with a thicker epithelium and a more structured lamina propria. Elastin fibers in fetal VF tissues were immature compared to those in adult tissues. Together, these structural changes in the tissues most likely contributed to the change in viscoelastic properties. Adult human VF tissues, recovered postmortem from adult patients with a history of smoking or disease, had an average storage modulus of 756±439 Pa and a loss tangent of 0.42±0.10. Contrary to the results of some other investigators, no significant frequency dependence was observed. This lack of observable frequency dependence may be due to the modest frequency range of the experiments and the wide range of stiffnesses observed within nominally similar sample types.

  3. High-Frequency Viscoelastic Shear Properties of Vocal Fold Tissues: Implications for Vocal Fold Tissue Engineering

    PubMed Central

    Teller, Sean S.; Farran, Alexandra J.E.; Xiao, Longxi; Jiao, Tong; Duncan, Randall L.

    2012-01-01

    The biomechanical function of the vocal folds (VFs) depends on their viscoelastic properties. Many conditions can lead to VF scarring that compromises voice function and quality. To identify candidate replacement materials, the structure, composition, and mechanical properties of native tissues need to be understood at phonation frequencies. Previously, the authors developed the torsional wave experiment (TWE), a stress-wave-based experiment to determine the linear viscoelastic shear properties of small, soft samples. Here, the viscoelastic properties of porcine and human VFs were measured over a frequency range of 10–200 Hz. The TWE utilizes resonance phenomena to determine viscoelastic properties; therefore, the specimen test frequency is determined by the sample size and material properties. Viscoelastic moduli are reported at resonance frequencies. Structure and composition of the tissues were determined by histology and immunochemistry. Porcine data from the TWE are separated into two groups: a young group, consisting of fetal and newborn pigs, and an adult group, consisting of 6–9-month olds and 2+-year olds. Adult tissues had an average storage modulus of 2309±1394 Pa and a loss tangent of 0.38±0.10 at frequencies of 36–200 Hz. The VFs of young pigs were significantly more compliant, with a storage modulus of 394±142 Pa and a loss tangent of 0.40±0.14 between 14 and 30 Hz. No gender dependence was observed. Histological staining showed that adult porcine tissues had a more organized, layered structure than the fetal tissues, with a thicker epithelium and a more structured lamina propria. Elastin fibers in fetal VF tissues were immature compared to those in adult tissues. Together, these structural changes in the tissues most likely contributed to the change in viscoelastic properties. Adult human VF tissues, recovered postmortem from adult patients with a history of smoking or disease, had an average storage modulus of 756±439 Pa and a loss tangent of 0.42±0.10. Contrary to the results of some other investigators, no significant frequency dependence was observed. This lack of observable frequency dependence may be due to the modest frequency range of the experiments and the wide range of stiffnesses observed within nominally similar sample types. PMID:22741523

  4. The effect of stimulus frequency on the analgesic response to percutaneous electrical nerve stimulation in patients with chronic low back pain.

    PubMed

    Ghoname, E S; Craig, W F; White, P F; Ahmed, H E; Hamza, M A; Gajraj, N M; Vakharia, A S; Noe, C E

    1999-04-01

    Low back pain (LBP) is one of the most common medical problems in our society. Increasingly, patients are turning to nonpharmacologic analgesic therapies such as percutaneous electrical nerve stimulation (PENS). We designed this sham-controlled study to compare the effect of three different frequencies of electrical stimulation on the analgesic response to PENS therapy. Sixty-eight consenting patients with LBP secondary to degenerative lumbar disc disease were treated with PENS therapy at 4 Hz, alternating 15 Hz and 30 Hz (15/30 Hz), and 100 Hz, as well as sham-PENS (0 Hz), according to a randomized, cross-over study design. Each treatment was administered for a period of 30 min three times per week for 2 wk. The pre- and posttreatment assessments included the health status survey short form and visual analog scales for pain, physical activity, and quality of sleep. After receiving all four treatments, patients completed a global assessment questionnaire. The sham-PENS treatments failed to produce changes in the degree of pain, physical activity, sleep quality, or daily intake of oral analgesic medications. In contrast, 4-Hz, 15/30-Hz, and 100-Hz stimulation all produced significant decreases in the severity of pain, increases in physical activity, improvements in the quality of sleep, and decreases in oral analgesic requirements (P < 0.01). Of the three frequencies, 15/30 Hz was the most effective in decreasing pain, increasing physical activity, and improving the quality of sleep (P < 0.05). In the global assessment, 40% of the patients reported that 15/30 Hz was the most desirable therapy, and it was also more effective in improving the patient's sense of well-being. We conclude that the frequency of electrical stimulation is an important determinant of the analgesic response to PENS therapy. Alternating stimulation at 15-Hz and 30-Hz frequencies was more effective than either 4 Hz or 100 Hz in improving outcome measures in patients with LBP. The frequency of electrical stimulation seems to be an important determinant of the analgesic efficacy of percutaneous electrical nerve stimulation. Mixed low- and high-frequency stimulation was more effective than either low or high frequencies alone in the treatment of patients with low back pain.

  5. Compact laser interferometer for translation and tilt measurement as optical readout for the LISA inertial sensor

    NASA Astrophysics Data System (ADS)

    Schuldt, Thilo; Gohlke, Martin; Weise, Dennis; Johann, Ulrich; Peters, Achim; Braxmaier, Claus

    2007-10-01

    The space mission LISA (Laser Interferometer Space Antenna) aims at detecting gravitational waves in the frequency range 30 μ Hz to 1Hz. Free flying proof masses inside the satellites act as inertial sensors and represent the end mirrors of the interferometer. In the current baseline design, LISA utilizes an optical readout of the position and tilt of the proof mass with respect to the satellite housing. This readout must have ~ 5pm/√Hz sensitivity for the translation measurement (for frequencies above 2.8mHz with an ƒ -2 relaxation down to 30 μHz) and ~ 10 nrad/√Hz sensitivity for the tilt measurement (for frequencies above 0.1mHz with an ƒ -1 relaxation down to 30 μHz). The University of Applied Sciences Konstanz (HTWG) - in collaboration with Astrium GmbH, Friedrichshafen, and the Humboldt-University Berlin - therefore develops a highly symmetric heterodyne interferometer implementing differential wavefront sensing for the tilt measurement. We realized a mechanically highly stable and compact setup. In a second, improved setup we measured initial noise levels below 5 pm/√Hz and 10 nrad/√Hz, respectively, for frequencies above 10mHz.

  6. Effects of processing parameters in the sonic assisted water extraction (SAWE) of 6-gingerol.

    PubMed

    Syed Jaapar, Syaripah Zaimah; Morad, Noor Azian; Iwai, Yoshio; Nordin, Mariam Firdhaus Mad

    2017-09-01

    The use of water in subcritical conditions for extraction has several drawbacks. These include the safety features, higher production costs and possible degradation of the bioactive compounds. To overcome these problems, sonic energy and an entrainer were used as external interventions to decrease the polarity of water at milder operating conditions. The effect of low (28kHz) and high (800kHz) frequencies of sonication in the extraction of the main ginger bioactive compound (6-gingerol) were compared. Six parameters were studied: mean particle size (MPS, mm), time of extraction, applied power, sample to solvent ratio (w/v), temperature of extraction, and the percentage of entrainer. The optimum conditions for high frequency SAWE prototype were MPS 0.89-1.77mm, 45min, 40W applied power, 1:30 (w/v), 45°C, and 15% of ethanol as entrainer. Two-way analysis of variance (ANOVA) gave the most significant parameter, which was power with F (1, 45.07), p<2.50×10 -9 . Although the effect of low frequency was stronger than high frequency, at the optimum conditions of the sample to solvent ratio 1:30 (w/v) with 700mL solvent and temperature 45°C, the concentration and recovery of 6-gingerol from high frequency of SAWE prototype was 2.69 times higher than at low frequency of SAWE. It was found that although the effects of high frequency (800kHz) were negligible in other studies, it could extract suitable compounds, such as 6-gingerol, at lower temperature. Therefore, the effects of sonication, which cause an enlargement in the cell wall of the ginger plant matrix, were observed using a Scanning Electron Microscope (SEM). It was found that the applied power of sonication was the most significant parameter compared to the other parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Auditory frequency generalization in the goldfish (Carassius auratus)1

    PubMed Central

    Fay, Richard R.

    1970-01-01

    Auditory frequency generalization in the goldfish was studied at five points within the best hearing range through the use of classical respiratory conditioning. Each experimental group received single-stimulus conditioning sessions at one of five stimulus frequencies (100, 200, 400, 800, and 1600 Hz), and were subsequently tested for generalization at eight neighboring frequencies. All stimuli were presented 30 db above absolute threshold. Significant generalization decrements were found for all subjects. For the subjects conditioned in the range between 100 and 800 Hz, a nearly complete failure to generalize was found at one octave above and below the training frequency. The subjects conditioned at 1600 Hz produced relatively more flat gradients between 900 and 2000 Hz. The widths of the generalization gradients, expressed in Hz, increased as a power function of frequency with a slope greater than one. PMID:16811481

  8. Electrodiagnostic applications of somatosensory evoked high-frequency EEG oscillations: Technical considerations.

    PubMed

    Simpson, A J; Cunningham, M O; Baker, M R

    2018-03-01

    High frequency oscillations (HFOs) embedded within the somatosensory evoked potential (SEP) are not routinely recorded/measured as part of standard clinical SEPs. However, HFOs could provide important additional diagnostic/prognostic information in various patient groups in whom SEPs are tested routinely. One area is the management of patients with hypoxic ischaemic encephalopathy (HIE) in the intensive care unit (ICU). However, the sensitivity of standard clinical SEP recording techniques for detecting HFOs is unknown. SEPs were recorded using routine clinical methods in 17 healthy subjects (median nerve stimulation; 0.5 ms pulse width; 5 Hz; maximum 4000 stimuli) in an unshielded laboratory. Bipolar EEG recordings were acquired (gain 50 k; bandpass 3Hz-2 kHz; sampling rate 5 kHz; non-inverting electrode 2 cm anterior to C3/C4; inverting electrode 2 cm posterior to C3/C4). Data analysis was performed in MATLAB. SEP-HFOs were detected in 65% of controls using standard clinical recording techniques. In 3 controls without significant HFOs, experiments were repeated using a linear electrode array with higher spatial sampling frequency. SEP-HFOs were observed in all 3 subjects. Currently standard clinical methods of recording SEPs are not sufficiently sensitive to permit the inclusion of SEP-HFOs in routine clinical diagnostic/prognostic assessments. Whilst an increase in the number/density of EEG electrodes should improve the sensitivity for detecting SEP-HFOs, this requires confirmation. By improving and standardising clinical SEP recording protocols to permit the acquisition/analysis of SEP-HFOs, it should be possible to gain important insights into the pathophysiology of neurological disorders and refine the management of conditions such as HIE. Copyright © 2018. Published by Elsevier Inc.

  9. The DESMEX Project - Deep Electromagnetic Sounding for Mineral EXploration

    NASA Astrophysics Data System (ADS)

    Meyer, U.; Becken, M.; Stolz, R.; Nittinger, C.; Cherevatova, M.; Siemon, B.; Martin, T.; Petersen, H.; Steuer, A.

    2017-12-01

    The DESMEX project (Deep Electromagnetic Sounding for Mineral Exploration) aims to develop independent semi-airborne frequency domain systems for mineral exploration down to depths of 1 km and deeper. Two different helicopter-towed systems are being designed and tested using source installations on ground. One system uses among other equipment conventional three axis induction coils, a 3D-fluxgate and a high precision inertial motion unit. The use of the two different magnetometers allows to record data in a broad frequency range from 1 Hz to 10 kHz. The second system uses a newly developed SQUID-based sensing system of a similar frequency range and a self made inertial motion unit. Horizontal electric dipole transmitters provided by the Leibniz Institute for Applied Geophysics in Hannover and the Institute of Geophysics and Meteorology of the University in Cologne are used as ground based sources. First system tests showed a good performance of both systems with general noise levels below 50 pT/root(Hz). Test flights above the common survey area proved that the desired depth of investigation can be achieved and that the data is consistent with the subsurface conductivity structures. In order to verify the data acquired from the newly developed system at shallow depths and to provide a better starting model for later inversion calculations helicopter borne frequency domain electromagnetics has been acquired and fully processed over the test site Schleiz - Greiz in Germany. To further relate the subsurface conductivity models to the subsurface geology and mineralogy, petrophysical investigations have been performed on rock samples from the site of investigation and analogue samples.

  10. Effects of Rate on Analgesia in Kilohertz Frequency Spinal Cord Stimulation: Results of the PROCO Randomized Controlled Trial

    PubMed Central

    Tavakkolizadeh, Moein; Love‐Jones, Sarah; Patel, Nikunj K.; Gu, Jianwen Wendy; Bains, Amarpreet; Doan, Que; Moffitt, Michael

    2017-01-01

    Objective The PROCO RCT is a multicenter, double‐blind, crossover, randomized controlled trial (RCT) that investigated the effects of rate on analgesia in kilohertz frequency (1–10 kHz) spinal cord stimulation (SCS). Materials and Methods Patients were implanted with SCS systems and underwent an eight‐week search to identify the best location (“sweet spot”) of stimulation at 10 kHz within the searched region (T8–T11). An electronic diary (e‐diary) prompted patients for pain scores three times per day. Patients who responded to 10 kHz per e‐diary numeric rating scale (ED‐NRS) pain scores proceeded to double‐blind rate randomization. Patients received 1, 4, 7, and 10 kHz SCS at the same sweet spot found for 10 kHz in randomized order (four weeks at each frequency). For each frequency, pulse width and amplitude were titrated to optimize therapy. Results All frequencies provided equivalent pain relief as measured by ED‐NRS (p ≤ 0.002). However, mean charge per second differed across frequencies, with 1 kHz SCS requiring 60–70% less charge than higher frequencies (p ≤ 0.0002). Conclusions The PROCO RCT provides Level I evidence for equivalent pain relief from 1 to 10 kHz with appropriate titration of pulse width and amplitude. 1 kHz required significantly less charge than higher frequencies. PMID:29220121

  11. Music students: conventional hearing thresholds and at high frequencies.

    PubMed

    Lüders, Débora; Gonçalves, Cláudia Giglio de Oliveira; Lacerda, Adriana Bender de Moreira; Ribas, Ângela; Conto, Juliana de

    2014-01-01

    Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. Study design was a retrospective observational cohort. Conventional and high-frequency audiometry was performed in 42 music students (Madsen Itera II audiometer and TDH39P headphones for conventional audiometry, and HDA 200 headphones for high-frequency audiometry). Of the 42 students, 38.1% were female students and 61.9% were male students, with a mean age of 26 years. At conventional audiometry, 92.85% had hearing thresholds within normal limits; but even within the normal limits, the worst results were observed in the left ear for all frequencies, except for 4000 Hz; compared to the non-musician group, the worst results occurred at 500 Hz in the left ear, and at 250 Hz, 6000 Hz, 9000 Hz, 10,000 Hz, and 11,200 Hz in both the ears. The periodic evaluation of high-frequency thresholds may be useful in the early detection of hearing loss in musicians. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  12. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei

    2014-11-01

    Recently, we found that by terminating a long length of fiber of up to 1 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large reenforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.

  13. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.; Li, Qian; Zhang, Yiwei

    2015-03-01

    We have recently found that a long length of fiber of up to 1 km terminated with an in-fiber cavity structure can detect vibrations over a frequency range from 5 Hz to 2 kHz. We want to determine whether the sensor (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to maintenance cost. The sensor may also help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that requires the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Acoustic vibration monitoring may need sensing at even higher frequencies (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed longgauge vibration sensor depends on packaging.

  14. Effect of renal nerve stimulation on responsiveness of the rat renal vasculature.

    PubMed

    DiBona, Gerald F; Sawin, Linda L

    2002-11-01

    When the renal nerves are stimulated with sinusoidal stimuli over the frequency range 0.04-0.8 Hz, low (< or =0.4 Hz)- but not high (> or =0.4 Hz)-frequency oscillations appear in renal blood flow (RBF) and are proposed to increase responsiveness of the renal vasculature to stimuli. This hypothesis was tested in anesthetized rats in which RBF responses to intrarenal injection of norepinephrine and angiotensin and to reductions in renal arterial pressure (RAP) were determined during conventional rectangular pulse and sinusoidal renal nerve stimulation. Conventional rectangular pulse renal nerve stimulation decreased RBF at 2 Hz but not at 0.2 or 1.0 Hz. Sinusoidal renal nerve stimulation elicited low-frequency oscillations (< or =0.4 Hz) in RBF only when the basal carrier signal frequency produced renal vasoconstriction, i.e., at 5 Hz but not at 1 Hz. Regardless of whether renal vasoconstriction occurred, neither conventional rectangular pulse nor sinusoidal renal nerve stimulation altered renal vasoconstrictor responses to norepinephrine and angiotensin. The RBF response to reduction in RAP was altered by both conventional rectangular pulse and sinusoidal renal nerve stimulation only when renal vasoconstriction occurred: the decrease in RBF during reduced RAP was greater. Sinusoidal renal nerve stimulation with a renal vasoconstrictor carrier frequency results in a decrease in RBF with superimposed low-frequency oscillations. However, these low-frequency RBF oscillations do not alter renal vascular responsiveness to vasoconstrictor stimuli.

  15. Investigation and Characterization of Acoustic Emissions of Tornadoes Using Arrays of Infrasound Sensors

    NASA Astrophysics Data System (ADS)

    Frazier, W. G.; Talmadge, C. L.; Waxler, R.; Knupp, K. R.; Goudeau, B.; Hetzer, C. H.

    2017-12-01

    Working in co-ordination with the NOAA Vortex Southeast (Vortex SE) research program, 9 infrasound sensor arrays were deployed at fixed sites across North Alabama, South-central Tennessee, and Northwest Georgia during March and April of 2017, to investigate the emission and characterization of infrasonic acoustic energy from tornadoes and related phenomena. Each array consisted of seven broadband acoustic sensors with calibrated frequency response from 0.02 Hz to 200 Hz. The arrays were configured in a pattern such that accurate bearings to acoustic sources could be obtained over a broad range of frequencies (nominally from 1 Hz to 100 Hz). Data were collected synchronously at a rate of 1000 samples per second. On 22 April 2017 a line of strong storms passed directly through the area being monitored producing at least three verified tornadoes. Two of these were rated at EF0 and the other an EF1. Subsequent processing of the data from several of the arrays revealed acoustic emissions from the tornadic storms ranging in frequencies below 1 Hz to frequencies greater than 10 Hz. Accurate bearings to the storms have been calculated from distances greater than 60 km. Preliminary analysis has revealed that continuous emissions occurred prior to the estimated touchdown times, while the storms were on the ground, and for short periods after the tornadoes lifted; however, the strongest emissions appeared to occur while the storms were on the ground. One of the storms passed near two arrays simultaneously, and therefore accurate an accurate track of the storm as it moved has been obtained only using the infrasound measurements. Initial results from the analysis of the infrasound data will be presented. Under Vortex SE meteorological data was collected on a large suite of sensors. Correlations between the infrasound data and the meteorological data will be investigated and discussed.

  16. 47 CFR 18.303 - Prohibited frequency bands.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...

  17. 47 CFR 18.303 - Prohibited frequency bands.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...

  18. 47 CFR 18.303 - Prohibited frequency bands.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...

  19. 47 CFR 18.303 - Prohibited frequency bands.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Prohibited frequency bands. 18.303 Section 18.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL... following safety, search and rescue frequency bands is prohibited: 490-510 kHz, 2170-2194 kHz, 8354-8374 kHz...

  20. Wind Speed Dependence of Acoustic Ambient Vertical Directional Spectra at High Frequency

    DTIC Science & Technology

    1989-05-26

    the measurements, which is 8 to 32 kHz, is sufficiently high that the propagation is adequately modeled using the Eikonal equation approximation. 4 TD...level spectra were calculated from the resulting time series. Spectral levels at 8, 16, and 32 kHz were recorded in a database along with the wind...indications of biological or industrial contaminations were removed. The resulting database seen here contained 215 samples. 10 * TD 8565 0z 00 a.I. cn

  1. Non-linear HRV indices under autonomic nervous system blockade.

    PubMed

    Bolea, Juan; Pueyo, Esther; Laguna, Pablo; Bailón, Raquel

    2014-01-01

    Heart rate variability (HRV) has been studied as a non-invasive technique to characterize the autonomic nervous system (ANS) regulation of the heart. Non-linear methods based on chaos theory have been used during the last decades as markers for risk stratification. However, interpretation of these nonlinear methods in terms of sympathetic and parasympathetic activity is not fully established. In this work we study linear and non-linear HRV indices during ANS blockades in order to assess their relation with sympathetic and parasympathetic activities. Power spectral content in low frequency (0.04-0.15 Hz) and high frequency (0.15-0.4 Hz) bands of HRV, as well as correlation dimension, sample and approximate entropies were computed in a database of subjects during single and dual ANS blockade with atropine and/or propranolol. Parasympathetic blockade caused a significant decrease in the low and high frequency power of HRV, as well as in correlation dimension and sample and approximate entropies. Sympathetic blockade caused a significant increase in approximate entropy. Sympathetic activation due to postural change from supine to standing caused a significant decrease in all the investigated non-linear indices and a significant increase in the normalized power in the low frequency band. The other investigated linear indices did not show significant changes. Results suggest that parasympathetic activity has a direct relation with sample and approximate entropies.

  2. 47 CFR 15.33 - Frequency range of radiated measurements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...

  3. 47 CFR 15.33 - Frequency range of radiated measurements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...

  4. 47 CFR 15.33 - Frequency range of radiated measurements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...

  5. 47 CFR 15.33 - Frequency range of radiated measurements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...

  6. Experimental study on the sound absorption characteristics of continuously graded phononic crystals

    NASA Astrophysics Data System (ADS)

    Zhang, X. H.; Qu, Z. G.; He, X. C.; Lu, D. L.

    2016-10-01

    Novel three-dimensional (3D) continuously graded phononic crystals (CGPCs) have been designed, and fabricated by 3D printing. Each of the CGPCs is an entity instead of a combination of several other samples, and the porosity distribution of the CGPC along the incident direction is nearly linear. The sound absorption characteristics of CGPCs were experimentally investigated and compared with those of uniform phononic crystals (UPCs) and discretely stepped phononic crystals (DSPCs). Experimental results show that CGPCs demonstrate excellent sound absorption performance because of their continuously graded structures. CGPCs have higher sound absorption coefficients in the large frequency range and more sound absorption coefficient peaks in a specific frequency range than UPCs and DSPCs. In particular, the sound absorption coefficients of the CGPC with a porosity of 0.6 and thickness of 30 mm are higher than 0.56 when the frequency is 1350-6300 Hz and are all higher than 0.2 in the studied frequency range (1000-6300 Hz). CGPCs are expected to have potential application in noise control, especially in the broad frequency and low-frequency ranges.

  7. Back extensor muscle fatigue at submaximal workloads assessed using frequency banding of the electromyographic signal.

    PubMed

    Cardozo, Adalgiso Coscrato; Gonçalves, Mauro; Dolan, Patricia

    2011-12-01

    Changes in the mean or median frequency of the electromyographic (EMG) power spectrum are often used to assess skeletal muscle fatigue. A more global analysis of the spectral changes using frequency banding may provide a more sensitive measure of fatigue than changes in mean or median frequency. So, the aim of the present study was to characterize changes in different power spectrum frequency bands and compare these with changes in median frequency. Twenty male subjects performed isometric contractions of the back muscles in an isometric dynamometer at 30%, 40%, 50% and 60% of maximum voluntary contraction. During each contraction, surface EMG signals were recorded from the right and left longissimus thoracis muscles, and endurance time was measured. The EMG power spectra were divided into four frequency bands (20-50 Hz; 50-80 Hz; 80-110 Hz; 110-140 Hz) and changes in power in each band with fatigue were compared with changes in median frequency. The percentage changes in 20-50 Hz band were greater than in all other and the rate of change in power, indicated by the slope, was also greatest in 20-50 Hz band. Also, 20-50 Hz band had a greater change in power than the median frequency. Power in the low frequency part of the EMG power spectrum increases with fatigue in a load-dependent manner. The rate of change in low frequency power may be a useful indicator of fatigue rate or "fatigability" in the back muscles. Also, changes in low frequency power are more evident than changes in the median frequency. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Chirping response of weakly electric knife fish (Apteronotus leptorhynchus) to low-frequency electric signals and to heterospecific electric fish.

    PubMed

    Dunlap, K D; DiBenedictis, B T; Banever, S R

    2010-07-01

    Brown ghost knife fish (Apteronotus leptorhynchus) can briefly increase their electric organ discharge (EOD) frequency to produce electrocommunication signals termed chirps. The chirp rate increases when fish are presented with conspecific fish or high-frequency (700-1100 Hz) electric signals that mimic conspecific fish. We examined whether A. leptorhynchus also chirps in response to artificial low-frequency electric signals and to heterospecific electric fish whose EOD contains low-frequency components. Fish chirped at rates above background when presented with low-frequency (10-300 Hz) sine-wave stimuli; at 30 and 150 Hz, the threshold amplitude for response was 1 mV cm(-1). Low-frequency (30 Hz) stimuli also potentiated the chirp response to high-frequency ( approximately 900 Hz) stimuli. Fish increased their chirp rate when presented with two heterospecific electric fish, Sternopygus macrurus and Brachyhypopomus gauderio, but did not respond to the presence of the non-electric fish Carassius auratus. Fish chirped to low-frequency (150 Hz) signals that mimic those of S. macrurus and to EOD playbacks of B. gauderio. The response to the B. gauderio playback was reduced when the low-frequency component (<150 Hz) was experimentally filtered out. Thus, A. leptorhynchus appears to chirp specifically to the electric signals of heterospecific electric fish, and the low-frequency components of heterospecific EODs significantly influence chirp rate. These results raise the possibility that chirps function to communicate to conspecifics about the presence of a heterospecific fish or to communicate directly to heterospecific fish.

  9. Potential Application of Environmental Noise Recordings in Geoarchaeological Site Characterization

    NASA Astrophysics Data System (ADS)

    Di Luzio, E.

    2015-12-01

    Environmental noise recordings are commonly applied in seismic microzonation studies. By calculating the H/V spectral ratio, the fundamental frequency of soft terrains overlying a rigid bedrock can be determined (Nakamura (1989). In such a simple two-layer system, equation f = n Vs/4H (1) links the resonance frequency "f" to the thickness "H" and shear waves velocity "Vs "of the resonating layer. In recent years, this methodology has been applied generally to obtain information on the seismostratigraphy of an investigated site in different environmental context. In this work, its potential application in the characterization of archaeological features hosted in shallow geological levels is discussed. Field cases are identified in the Appia Antica archaeological site which is placed in central Italy. Here, acknowledged targets correspond to: i) empty tanks carved by the Romans into Cretaceous limestone in the IV-III cen. BC and ii): the basaltic stone paving of the ancient road track which is locally buried beneath colluvial deposits. Narrowly-spaced recordings of environmental noise were carried using a portable digital seismograph equipped with three electrodynamic orthogonal sensors (velocimeters) responding in the band 0.1 ÷1024 Hz and adopting a sampling frequency of 256 Hz.. Results are discussed in terms of absolute H/V values and related distribution maps in the very high-frequency interval of 10-40Hz. In the tanks hosting area, interpolation of H/V maximum values around 13Hz matches caves location and alignment, which is also evidenced by clear inversions (H/V<1) at lower frequencies (10-1Hz). Correlation between H/V peaks and the top surface of the buried stone paving along the prosecution of the road track is even more straightforward. Finally, the depth variations of the tank roofs and the basaltic paving were reconstructed combining in equation (1) results of noise recordings with borehole data and geophysical surveys (SASW analysis).

  10. Three-dimensional organization of otolith-ocular reflexes in rhesus monkeys. III. Responses To translation

    NASA Technical Reports Server (NTRS)

    Angelaki, D. E.

    1998-01-01

    The three-dimensional (3-D) properties of the translational vestibulo-ocular reflexes (translational VORs) during lateral and fore-aft oscillations in complete darkness were studied in rhesus monkeys at frequencies between 0.16 and 25 Hz. In addition, constant velocity off-vertical axis rotations extended the frequency range to 0.02 Hz. During lateral motion, horizontal responses were in phase with linear velocity in the frequency range of 2-10 Hz. At both lower and higher frequencies, phase lags were introduced. Torsional response phase changed more than 180 degrees in the tested frequency range such that torsional eye movements, which could be regarded as compensatory to "an apparent roll tilt" at the lowest frequencies, became anticompensatory at all frequencies above approximately 1 Hz. These results suggest two functionally different frequency bandwidths for the translational VORs. In the low-frequency spectrum (<<0.5 Hz), horizontal responses compensatory to translation are small and high-pass-filtered whereas torsional response sensitivity is relatively frequency independent. At higher frequencies however, both horizontal and torsional response sensitivity and phase exhibit a similar frequency dependence, suggesting a common role during head translation. During up-down motion, vertical responses were in phase with translational velocity at 3-5 Hz but phase leads progressively increased for lower frequencies (>90 degrees at frequencies <0.2 Hz). No consistent dependence on static head orientation was observed for the vertical response components during up-down motion and the horizontal and torsional response components during lateral translation. The frequency response characteristics of the translational VORs were fitted by "periphery/brain stem" functions that related the linear acceleration input, transduced by primary otolith afferents, to the velocity signals providing the input to the velocity-to-position neural integrator and the oculomotor plant. The lowest-order, best-fit periphery/brain stem model that approximated the frequency dependence of the data consisted of a second order transfer function with two alternating poles (at 0.4 and 7.2 Hz) and zeros (at 0.035 and 3.4 Hz). In addition to clearly differentiator dynamics at low frequencies (less than approximately 0.5 Hz), there was no frequency bandwidth where the periphery/brain stem function could be approximated by an integrator, as previously suggested. In this scheme, the oculomotor plant dynamics are assumed to perform the necessary high-frequency integration as required by the reflex. The detailed frequency dependence of the data could only be precisely described by higher order functions with nonminimum phase characteristics that preclude simple filtering of afferent inputs and might be suggestive of distributed spatiotemporal processing of otolith signals in the translational VORs.

  11. Developments of high frequency and intensity stabilized lasers for space gravitational wave detector DECIGO/B-DECIGO

    NASA Astrophysics Data System (ADS)

    Suemasa, Aru; Shimo-oku, Ayumi; Nakagawa, Ken'ichi; Musha, Mitsuru

    2017-12-01

    In Japan, not only the ground-based gravitational wave (GW) detector mission KAGRA but also the space GW detector mission DECIGO (DECi-hertz Interferometer Gravitational wave Observatory) and its milestone mission B-DECIGO have been promoted. The designed strain sensitivity of DECIGO and B-DECIGO are δL/ L < 10-23. Since the GW detector requires high power and highly-stable light source, we have developed the light source with high frequency and intensity stability for DECIGO and B-DECIGO. The frequency of the Yb-doped fiber DFB lasers are stabilized to the iodine saturated absorption at 515 nm, and the intensity of the laser at 1 Hz (observation band) is stabilized by controlling the pump source of an Yb-doped fiber amplifier. The intensity of the laser at 200 kHz (modulation band) is also stabilized using an acousto-optic modulator to improve the frequency stability of the laser. In the consequences, we obtain the frequency stability of δf = 0.4 Hz/√Hz (in-loop) at 1 Hz, and the intensity stability of δI/ I = 1.2 × 10-7/√Hz (out-of-loop) and δI/I = 1.5 × 10-7/√Hz (in-loop) at 1 Hz and 200 kHz, respectively.

  12. A Sensitive, Multifunctional Spinner Magnetometer Using Magneto-impedance Sensor: a Rapid and Convenient Tool for the Quantification of Inhomogeneity of Magnetization

    NASA Astrophysics Data System (ADS)

    Kodama, K.

    2016-12-01

    A new type of spinner magnetometer with wide dynamic range from 10-7 mAm2 to 10-1 mAm2 and the resolution of 10-8 mAm2 was developed. The high sensitivity was achieved by using magneto-impedance (MI) sensor, a compact, high-performance magnetic sensor used in industrial fields. The slow spinning speed (5 Hz) and the unique mechanism enabling the adjustment of the sample-sensor distance allow measurements of fragile samples in any shape and size. A differential arrangement connecting a pair of the MI sensors in opposite serial reduces external noise and temperature drift. The differential sensor output is transferred to an amplification circuit associated with a programmable low-pass filter. The signal with reference to the spinning frequency is detected with a digital lock-in amplifier. The spinner magnetometer has two selectable measurement modes, the fundamental-mode (F-mode) and the harmonic-mode (H-mode). Measurements in the F-mode detect signals oscillating at the fundamental frequency (5 Hz) as conventional spinner magnetometers do. In the H-mode, additionally, the second (10 Hz) and the third (15 Hz) harmonic components can be measured. Tests in the H-mode were performed using a small coil and changing its position to simulate an offset-dipole. The results demonstrate that the dipole moment of the fundamental component is systematically biased by both quadrupole and octupole components arising in practice from inhomogeneity of magnetization or irregularity of sample shape. This study proposes, combined with theoretical and numerical analyses, quantification of such non-dipole effects and associated errors in the determination of dipole moment of a sample, as well as their correction that may be necessary, for example, when measuring irregular-shaped samples in the proximity of the sensor.

  13. The frequency dependence of the viscous component of the magnetic susceptibility of lunar rock and soil samples

    NASA Technical Reports Server (NTRS)

    Hanneken, J. W.; Vant-Hull, L. L.; Carnes, J. G.

    1976-01-01

    The susceptibility of two lunar samples (a soil and a low metamorphic grade breccia) has been measured in a weak field - 0.001 Oe - and as a function of frequency from 0.032 to 1.0 Hz. The measurements were made using a superconducting magnetometer. The results show that the susceptibility decreases linearly with the log of frequency. This observation is in agreement with a theoretical model for viscous decay based on the Neel theory of single-domain and superparamagnetic grains. The relation derived agrees with a model in which there is a uniform distribution of relaxation times.

  14. Developments in dynamic MR elastography for in vitro biomechanical assessment of hyaline cartilage under high-frequency cyclical shear.

    PubMed

    Lopez, Orlando; Amrami, Kimberly K; Manduca, Armando; Rossman, Phillip J; Ehman, Richard L

    2007-02-01

    The design, construction, and evaluation of a customized dynamic magnetic resonance elastography (MRE) technique for biomechanical assessment of hyaline cartilage in vitro are described. For quantification of the dynamic shear properties of hyaline cartilage by dynamic MRE, mechanical excitation and motion sensitization were performed at frequencies in the kilohertz range. A custom electromechanical actuator and a z-axis gradient coil were used to generate and image shear waves throughout cartilage at 1000-10,000 Hz. A radiofrequency (RF) coil was also constructed for high-resolution imaging. The technique was validated at 4000 and 6000 Hz by quantifying differences in shear stiffness between soft ( approximately 200 kPa) and stiff ( approximately 300 kPa) layers of 5-mm-thick bilayered phantoms. The technique was then used to quantify the dynamic shear properties of bovine and shark hyaline cartilage samples at frequencies up to 9000 Hz. The results demonstrate that one can obtain high-resolution shear stiffness measurements of hyaline cartilage and small, stiff, multilayered phantoms at high frequencies by generating robust mechanical excitations and using large magnetic field gradients. Dynamic MRE can potentially be used to directly quantify the dynamic shear properties of hyaline and articular cartilage, as well as other cartilaginous materials and engineered constructs. (c) 2007 Wiley-Liss, Inc.

  15. Vestibular evoked myogenic potential (VEMP) testing: normative threshold response curves and effects of age.

    PubMed

    Janky, Kristen L; Shepard, Neil

    2009-09-01

    Vestibular evoked myogenic potential (VEMP) testing has gained increased interest in the diagnosis of a variety of vestibular etiologies. P13/N23 latency, amplitude and threshold response curves have been used to compare pathologic groups to normal controls. Appropriate characterization of these etiologies requires normative data across the frequency spectrum and age range. The objective of the current study was to test the hypothesis that significant changes in VEMP responses occur as a function of increased age across all test stimuli as well as characterize the VEMP threshold response curve across age. This project incorporated a prospective study design using a sample of convenience. Openly recruited subjects were assigned to groups according to age. Forty-six normal controls ranging between 20 and 76 years of age participated in the study. Participants were separated by decade into five age categories from 20 to 60 plus years. Normal participants were characterized by having normal hearing sensitivity, no history of neurologic or balance/dizziness involvement, and negative results on a direct office vestibular examination. VEMP responses were measured at threshold to click and 250, 500, 750, and 1000 Hz tone burst stimuli and at a suprathreshold level to 500 Hz toneburst stimuli at123 dB SPL. A mixed group factorial ANOVA (analysis of variance) and linear regression were performed to examine the effects of VEMP characteristics on age. There were no significant differences between ears for any of the test parameters. There were no significant differences between age groups for n23 latency or amplitude in response to any of the stimuli. Significant mean differences did exist between age groups for p13 latency (250, 750, and 1000 Hz) and threshold (500 and 750 Hz). Age was significantly correlated with VEMP parameters. VEMP threshold was positively correlated (250, 500, 750, 1000 Hz); and amplitude was negatively correlated (500 Hz maximum). The threshold response curves revealed best frequency tuning at 500 Hz with the highest thresholds in response to click stimuli. However, this best frequency tuning dissipated with increased age. VEMP response rates also decreased with increased age. We have demonstrated that minor differences in VEMP responses occur with age. Given the reduced response rates and flattened frequency tuning curve for individuals over the age of 60, frequency tuning curves may not be a good diagnostic indicator for this age group.

  16. Onboard software of Plasma Wave Experiment aboard Arase: instrument management and signal processing of Waveform Capture/Onboard Frequency Analyzer

    NASA Astrophysics Data System (ADS)

    Matsuda, Shoya; Kasahara, Yoshiya; Kojima, Hirotsugu; Kasaba, Yasumasa; Yagitani, Satoshi; Ozaki, Mitsunori; Imachi, Tomohiko; Ishisaka, Keigo; Kumamoto, Atsushi; Tsuchiya, Fuminori; Ota, Mamoru; Kurita, Satoshi; Miyoshi, Yoshizumi; Hikishima, Mitsuru; Matsuoka, Ayako; Shinohara, Iku

    2018-05-01

    We developed the onboard processing software for the Plasma Wave Experiment (PWE) onboard the Exploration of energization and Radiation in Geospace, Arase satellite. The PWE instrument has three receivers: Electric Field Detector, Waveform Capture/Onboard Frequency Analyzer (WFC/OFA), and the High-Frequency Analyzer. We designed a pseudo-parallel processing scheme with a time-sharing system and achieved simultaneous signal processing for each receiver. Since electric and magnetic field signals are processed by the different CPUs, we developed a synchronized observation system by using shared packets on the mission network. The OFA continuously measures the power spectra, spectral matrices, and complex spectra. The OFA obtains not only the entire ELF/VLF plasma waves' activity but also the detailed properties (e.g., propagation direction and polarization) of the observed plasma waves. We performed simultaneous observation of electric and magnetic field data and successfully obtained clear wave properties of whistler-mode chorus waves using these data. In order to measure raw waveforms, we developed two modes for the WFC, `chorus burst mode' (65,536 samples/s) and `EMIC burst mode' (1024 samples/s), for the purpose of the measurement of the whistler-mode chorus waves (typically in a frequency range from several hundred Hz to several kHz) and the EMIC waves (typically in a frequency range from a few Hz to several hundred Hz), respectively. We successfully obtained the waveforms of electric and magnetic fields of whistler-mode chorus waves and ion cyclotron mode waves along the Arase's orbit. We also designed the software-type wave-particle interaction analyzer mode. In this mode, we measure electric and magnetic field waveforms continuously and transfer them to the mission data recorder onboard the Arase satellite. We also installed an onboard signal calibration function (onboard SoftWare CALibration; SWCAL). We performed onboard electric circuit diagnostics and antenna impedance measurement of the wire-probe antennas along the orbit. We utilize the results obtained using the SWCAL function when we calibrate the spectra and waveforms obtained by the PWE.[Figure not available: see fulltext.

  17. The brain responses to different frequencies of binaural beat sounds on QEEG at cortical level.

    PubMed

    Jirakittayakorn, Nantawachara; Wongsawat, Yodchanan

    2015-01-01

    Beat phenomenon is occurred when two slightly different frequency waves interfere each other. The beat can also occur in the brain by providing two slightly different frequency waves separately each ear. This is called binaural beat. The brain responses to binaural beat are in discussion process whether the brain side and the brain area. Therefore, this study aims to figure out the brain responses to binaural beat by providing different binaural beat frequencies on 250 carrier tone continuously for 30 minutes to participants and using quantitative electroencephalography (QEEG) to interpret the data. The result shows that different responses appear in different beat frequency. Left hemisphere dominance occur in 3 Hz beat within 15 minutes and 15 Hz beat within 5 minutes. Right hemisphere dominance occurs in 10 Hz beat within 25 minute. 6 Hz beat enhances all area of the brain within 10 minutes. 8 Hz and 25 Hz beats have no clearly responses while 40 Hz beat enhances the responses in frontal lobe. These brain responses can be used for brain modulation application to induce the brain activity in further studies.

  18. Comparison effects and dielectric properties of different dose methylene-blue-doped hydrogels.

    PubMed

    Yalçın, O; Coşkun, R; Okutan, M; Öztürk, M

    2013-08-01

    The dielectric properties of methylene blue (MB)-doped hydrogels were investigated by impedance spectroscopy. The real part (ε') and the imaginary part (ε") of the complex dielectric constant and the energy loss tangent/dissipation factor (tan δ) were measured in the frequency range of 10 Hz to 100 MHz at room temperature for pH 5.5 value. Frequency variations of the resistance, the reactance, and the impedance of the samples have also been investigated. The dielectric permittivity of the MB-doped hydrogels is sensitive to ionic conduction and electrode polarization in low frequency. Furthermore, the dielectric behavior in high-frequency parts was attributed to the Brownian motion of the hydrogen bonds. The ionic conduction for MB-doped samples was prevented for Cole-Cole plots, while the Cole-Cole plots for pure sample show equivalent electrical circuit. The alternative current (ac) conductivity increases with the increasing MB concentration and the frequency.

  19. Implementation of spatial overlap modulation nonlinear optical microscopy using an electro-optic deflector

    PubMed Central

    Isobe, Keisuke; Kawano, Hiroyuki; Kumagai, Akiko; Miyawaki, Atsushi; Midorikawa, Katsumi

    2013-01-01

    A spatial overlap modulation (SPOM) technique is a nonlinear optical microscopy technique which enhances the three-dimensional spatial resolution and rejects the out-of-focus background limiting the imaging depth inside a highly scattering sample. Here, we report on the implementation of SPOM in which beam pointing modulation is achieved by an electro-optic deflector. The modulation and demodulation frequencies are enhanced to 200 kHz and 400 kHz, respectively, resulting in a 200-fold enhancement compared with the previously reported system. The resolution enhancement and suppression of the out-of-focus background are demonstrated by sum-frequency-generation imaging of pounded granulated sugar and deep imaging of fluorescent beads in a tissue-like phantom, respectively. PMID:24156055

  20. Dielectric relaxation spectroscopy of aqueous solutions of diclofenac potassium over the frequency range of 20 Hz to 2 MHz at 303.15 K temperature

    NASA Astrophysics Data System (ADS)

    Karakthala, J. B.; Vankar, H. P.; Rana, V. A.

    2018-05-01

    The complex relative dielectric function ɛ*(ω) = ɛ' - jɛ″ of aqueous solutions of diclofenac potassium (DK) in the frequency range 20 Hz to 2 MHz at 303.15 K was measured using a precision LCR meter. The electrical/dielectric properties of the solutions samples were represented in terms of complex relative dielectric function ɛ*(ω) real part σ'(ω) of complex ac conductivity and dc conductivity. These types of studies can be used to explore various mechanism contributed in the absorption, transportation of drug through tissues and membranes of body as well as interactions of drug with body fluid and blood plasma.

  1. Programmable frequency reference for subkilohertz laser stabilization by use of persistent spectral hole burning.

    PubMed

    Sellin, P B; Strickland, N M; Carlsten, J L; Cone, R L

    1999-08-01

    We report what is believed to be the first demonstration of laser frequency stabilization directly to persistent spectral holes in a solid-state material. The frequency reference material was deuterated CaF(2): Tm(3+) prepared with 25-MHz-wide persistent spectral holes on the H(6)(3)?H(4)(3) transition at 798 nm. The beat frequency between two lasers that were independently locked to persistent spectral holes in separate crystal samples showed typical root Allan variances of 780+/-120Hz for 20-50-ms integration times.

  2. Ultra-fast magnetic resonance encephalography of physiological brain activity – Glymphatic pulsation mechanisms?

    PubMed Central

    Wang, Xindi; Korhonen, Vesa; Keinänen, Tuija; Tuovinen, Timo; Autio, Joonas; LeVan, Pierre; Keilholz, Shella; Zang, Yu-Feng; Hennig, Jürgen; Nedergaard, Maiken

    2015-01-01

    The theory on the glymphatic convection mechanism of cerebrospinal fluid holds that cardiac pulsations in part pump cerebrospinal fluid from the peri-arterial spaces through the extracellular tissue into the peri-venous spaces facilitated by aquaporin water channels. Since cardiac pulses cannot be the sole mechanism of glymphatic propulsion, we searched for additional cerebrospinal fluid pulsations in the human brain with ultra-fast magnetic resonance encephalography. We detected three types of physiological mechanisms affecting cerebral cerebrospinal fluid pulsations: cardiac, respiratory, and very low frequency pulsations. The cardiac pulsations induce a negative magnetic resonance encephalography signal change in peri-arterial regions that extends centrifugally and covers the brain in ≈1 Hz cycles. The respiratory ≈0.3 Hz pulsations are centripetal periodical pulses that occur dominantly in peri-venous areas. The third type of pulsation was very low frequency (VLF 0.001–0.023 Hz) and low frequency (LF 0.023–0.73 Hz) waves that both propagate with unique spatiotemporal patterns. Our findings using critically sampled magnetic resonance encephalography open a new view into cerebral fluid dynamics. Since glymphatic system failure may precede protein accumulations in diseases such as Alzheimer's dementia, this methodological advance offers a novel approach to image brain fluid dynamics that potentially can enable early detection and intervention in neurodegenerative diseases. PMID:26690495

  3. Ultra-fast magnetic resonance encephalography of physiological brain activity - Glymphatic pulsation mechanisms?

    PubMed

    Kiviniemi, Vesa; Wang, Xindi; Korhonen, Vesa; Keinänen, Tuija; Tuovinen, Timo; Autio, Joonas; LeVan, Pierre; Keilholz, Shella; Zang, Yu-Feng; Hennig, Jürgen; Nedergaard, Maiken

    2016-06-01

    The theory on the glymphatic convection mechanism of cerebrospinal fluid holds that cardiac pulsations in part pump cerebrospinal fluid from the peri-arterial spaces through the extracellular tissue into the peri-venous spaces facilitated by aquaporin water channels. Since cardiac pulses cannot be the sole mechanism of glymphatic propulsion, we searched for additional cerebrospinal fluid pulsations in the human brain with ultra-fast magnetic resonance encephalography. We detected three types of physiological mechanisms affecting cerebral cerebrospinal fluid pulsations: cardiac, respiratory, and very low frequency pulsations. The cardiac pulsations induce a negative magnetic resonance encephalography signal change in peri-arterial regions that extends centrifugally and covers the brain in ≈1 Hz cycles. The respiratory ≈0.3 Hz pulsations are centripetal periodical pulses that occur dominantly in peri-venous areas. The third type of pulsation was very low frequency (VLF 0.001-0.023 Hz) and low frequency (LF 0.023-0.73 Hz) waves that both propagate with unique spatiotemporal patterns. Our findings using critically sampled magnetic resonance encephalography open a new view into cerebral fluid dynamics. Since glymphatic system failure may precede protein accumulations in diseases such as Alzheimer's dementia, this methodological advance offers a novel approach to image brain fluid dynamics that potentially can enable early detection and intervention in neurodegenerative diseases. © The Author(s) 2015.

  4. Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    PubMed

    Jiang, Shangyuan; Gan, Rong Z

    2018-04-01

    The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the dynamic properties of the human ISJ measured in eight samples using a dynamic mechanical analyzer (DMA) for frequencies from 1 to 80 Hz at three temperatures of 5, 25 and 37 °C. The frequency-temperature superposition (FTS) principle was used to extrapolate the results to 8 kHz. The complex modulus of ISJ was measured with a mean storage modulus of 1.14 MPa at 1 Hz that increased to 3.01 MPa at 8 kHz, and a loss modulus that increased from 0.07 to 0.47 MPa. A 3-dimensional finite element (FE) model consisting of the articular cartilage, joint capsule and synovial fluid was then constructed to derive mechanical properties of ISJ components by matching the model results to experimental data. Modeling results showed that mechanical properties of the joint capsule and synovial fluid affected the dynamic behavior of the joint. This study contributes to a better understanding of the structure-function relationship of the ISJ for sound transmission. Copyright © 2018. Published by Elsevier Ltd.

  5. A frequency domain analysis of respiratory variations in the seismocardiogram signal.

    PubMed

    Pandia, Keya; Inan, Omer T; Kovacs, Gregory T A

    2013-01-01

    The seismocardiogram (SCG) signal traditionally measured using a chest-mounted accelerometer contains low-frequency (0-100 Hz) cardiac vibrations that can be used to derive diagnostically relevant information about cardiovascular and cardiopulmonary health. This work is aimed at investigating the effects of respiration on the frequency domain characteristics of SCG signals measured from 18 healthy subjects. Toward this end, the 0-100 Hz SCG signal bandwidth of interest was sub-divided into 5 Hz and 10 Hz frequency bins to compare the spectral energy in corresponding frequency bins of the SCG signal measured during three key conditions of respiration--inspiration, expiration, and apnea. Statistically significant differences were observed between the power in ensemble averaged inspiratory and expiratory SCG beats and between ensemble averaged inspiratory and apneaic beats across the 18 subjects for multiple frequency bins in the 10-40 Hz frequency range. Accordingly, the spectral analysis methods described in this paper could provide complementary and improved classification of respiratory modulations in the SCG signal over and above time-domain SCG analysis methods.

  6. Studies on Auditory and Vestibular End Organs and Brain Stem Nuclei. [inner ear damage and hearing defects

    NASA Technical Reports Server (NTRS)

    Ades, H. W.

    1974-01-01

    Cats were exposed to tones of 125, 1000, 2000, and 4000 Hz at sound pressure levels in the range 120 to 157.5 db, and for durations of one hour (1000, 2000, 4000 Hz) or four hours (125 Hz). Pure tone audiograms were obtained for each animal before and after exposure. Cochleas of animals were examined by phase-contrast microscopy. Extent of inner ear damage and range of frequencies for which hearing loss occurred increased as exposure tone was decreased in frequency. For example, exposure to 4000 Hz produced damage in a restricted region of the cochlea and hearing loss for a relatively narrow range of frequencies; exposure to 125 Hz produced wide-spread inner ear damage and hearing loss throughout the frequency range 125 to 6000 Hz.

  7. Development of a long-gauge vibration sensor

    NASA Astrophysics Data System (ADS)

    Kung, Peter; Comanici, Maria I.

    2014-06-01

    Recently, we found that by terminating a long length of fiber of up to 2 km with an in-fiber cavity structure, the entire structure can detect vibrations over a frequency range from 5 Hz to 100 Hz. We want to determine whether the structure (including packaging) can be optimized to detect vibrations at even higher frequencies. The structure can be used as a distributed vibration sensor mounted on large motors and other rotating machines to capture the entire frequency spectrum of the associated vibration signals, and therefore, replace the many accelerometers, which add to the maintenance cost. Similarly, it will help detect in-slot vibrations which cause intermittent contact leading to sparking under high voltages inside air-cooled generators. However, that will require the sensor to detect frequencies associated with vibration sparking, ranging from 6 kHz to 15 kHz. Then, at even higher frequencies, the structure can be useful to detect acoustic vibrations (30 kHz to 150 kHz) associated with partial discharge (PD) in generators and transformers. Detecting lower frequencies in the range 2 Hz to 200 Hz makes the sensor suitable for seismic studies and falls well into the vibrations associated with rotating machines. Another application of interest is corrosion detection in large re-enforced concrete structures by inserting the sensor along a long hole drilled around structures showing signs of corrosion. The frequency response for the proposed long-gauge vibration sensor depends on packaging.

  8. Masking of thresholds for the perception of fore-and-aft vibration of seat backrests.

    PubMed

    Morioka, Miyuki; Griffin, Michael J

    2015-09-01

    The detection of a vibration may be reduced by the presence of another vibration: a phenomenon known as 'masking'. This study investigated how the detection of one frequency of vibration is influenced by vibration at another frequency. With nine subjects, thresholds for detecting fore-and-aft backrest vibration were determined (for 4, 8, 16, and 31.5-Hz sinusoidal vibration) in the presence of a masker vibration (4-Hz random vibration, 1/3-octave bandwidth at six intensities). The masker vibration increased thresholds for perceiving vibration at each frequency by an amount that reduced with increasing difference between the frequency of the sinusoidal vibration and the frequency of the masker vibration. The 4-Hz random vibration almost completely masked 4-Hz sinusoidal vibration, partially masked 8- and 16-Hz vibration, and only slightly masked 31.5-Hz vibration. The findings might be explained by the involvement of different sensory systems and different body locations in the detection of different frequencies of vibration. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. A low-cost acoustic permeameter

    NASA Astrophysics Data System (ADS)

    Drake, Stephen A.; Selker, John S.; Higgins, Chad W.

    2017-04-01

    Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components - consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope - are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10-7 to 3 × 10-9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.

  10. Site response assessment at the city of Alkhobar, Eastern Saudi Arabia from microtremor and boring data

    NASA Astrophysics Data System (ADS)

    Fnais, M. S.

    2014-12-01

    The AlKhobar City affected by distant earthquakes from Zagros fold-fault belt of subduction zone. These earthquakes produced great site effects on the sedimentary layers that in turn significantly influenced earthquake ground motions in the area. Mapping of site response using microtremor measurements compared with geological and borehole data of Alkhobar city is the main target of this work. The resonance frequency and their H/V values have been calculated using Nakamura technique through deployed of seismograph instruments at 113 sites in AlKhobar city for different time periods. The recording length was about one hour with sampling frequency of 100 Hz. Most of the measured sites present three peaks for the resonance frequency; the first peak ranges from 0.33 to 1.03 Hz, the second peak ranges from 1.03 to 1.23 Hz, while the third peak ranges from 1.23-1.73. Tests have been conducted to ensure that these peaks are natural in origin. The northern zones of AlKhobar City have lower values of resonance frequency indicating great thickness of sediments. In contrast, the southern parts of the city have higher values of resonance frequency illustrating shallow depths of the bedrock. Furthermore, twenty of boreholes have been conducted through AlKhobar City to different depth. Standard penetration test (SPT) data has been corrected and used to calculate the resonance frequency at their locations. Borehole results clarified that the resonance frequency values range from 0.27 to 1.95 Hz. These results are correlated well with that of the microtremor measurements. Accordingly, the first peak have been interpreted due to the impedance contrast between the limestone and the overlying sediments, while the third peak is originated from a boundary between the upper most surface layer and the underlying sediments. These results must be applied for earthquake risk mitigation in AlKhobar City.

  11. Acoustic levitator for structure measurements on low temperature liquid droplets.

    PubMed

    Weber, J K R; Rey, C A; Neuefeind, J; Benmore, C J

    2009-08-01

    A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 degrees C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of approximately 22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

  12. Acoustic levitator for structure measurements on low temperature liquid droplets

    NASA Astrophysics Data System (ADS)

    Weber, J. K. R.; Rey, C. A.; Neuefeind, J.; Benmore, C. J.

    2009-08-01

    A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops of 1-3 mm in diameter at temperatures in the range -40 to +40 °C. The levitator comprised (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) an acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1 kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ˜22 kHz and could produce sound pressure levels of up to 160 dB. The force applied by the acoustic field could be modulated to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

  13. Underwater characterizations of monolithic piezoceramic and 1-3 composite using a self-designed transducer

    NASA Astrophysics Data System (ADS)

    Saleem Mirza, Muhammad; Yasin, Tariq; Ikram, Masroor; Altaf, Muhammad; Mushtaq, Zahir; Nasir Khan, Muhammad

    2016-03-01

    Underwater characterizations of (Pb0.94Sr0.04)(Zr0.52Ti0.48)O3 (PZT) and PZT/araldite-F 1-3 composite were carried out through a self-designed transducer. Disc-shaped samples of bulk PZT and PZT/araldite-F composite were first characterized in air and then were assembled in the transducer individually. The transducer's underwater voltage receiving sensitivity (Sh) and transmitting voltage response (Sv) were investigated in the frequency range of 10-200 kHz (well below thickness mode resonance) using a calibrated projector and receiver method with pulse technique. Results revealed that the transducer made with composite sample exhibited better (Sh) values (-214 dB ref 1 V/µPa) due to ~295% higher piezoelectric voltage coefficient gh (30 × 10-3 Vm/N) of the composite compared to PZT. In addition, the transducer with the PZT sample showed better Sv values (80 dB ref 1 µPa/1 V at 1 m) due to the presence of planar mode peaks in the frequency range of 10-200 kHz. These results indicate that the monolithic piezoceramic can exhibit underwater Sv response in both planar and thickness resonance modes owing to the admittance peaks in these frequency regions.

  14. The RF spectra of first and subsequent lightning return strokes in the 1- to 200-km range

    NASA Technical Reports Server (NTRS)

    Serhan, G. I.; Uman, M. A.; Childers, D. G.; Lin, Y. T.

    1980-01-01

    An experimental characterization of the frequency spectra of first and subsequent stroke electric fields are presented over a distance range from about 1 km, where the fields are primarily electrostatic, to 200 km, where they are primarily radiation. Spectra are presented to about 700 kHz for lightning within 12 km and to about 300 kHz for lightning at 50 and 200 km. It is shown that the return stroke ground wave spectrum beyond 50 km has a peak near 4 kHz but that within 10 km the spectrum shows a steady increase with decreasing frequency to 1 kHz. Frequency spectra at all ranges fall off roughly as 1/f for frequencies between 5 and 100 kHz, while the falloff above 100 kHz is faster as the distance to the stroke increases. From this high-frequency attenuation an RF conductivity for central Florida of between 0.002 and 0.005/ohm/m was determined.

  15. Sound pressure distribution and power flow within the gerbil ear canal from 100 Hz to 80 kHz

    PubMed Central

    Ravicz, Michael E.; Olson, Elizabeth S.; Rosowski, John J.

    2008-01-01

    Sound pressure was mapped in the bony ear canal of gerbils during closed-field sound stimulation at frequencies from 0.1 to 80 kHz. A 1.27-mm-diam probe-tube microphone or a 0.17-mm-diam fiber-optic miniature microphone was positioned along approximately longitudinal trajectories within the 2.3-mm-diam ear canal. Substantial spatial variations in sound pressure, sharp minima in magnitude, and half-cycle phase changes occurred at frequencies >30 kHz. The sound frequencies of these transitions increased with decreasing distance from the tympanic membrane (TM). Sound pressure measured orthogonally across the surface of the TM showed only small variations at frequencies below 60 kHz. Hence, the ear canal sound field can be described fairly well as a one-dimensional standing wave pattern. Ear-canal power reflectance estimated from longitudinal spatial variations was roughly constant at 0.2–0.5 at frequencies between 30 and 45 kHz. In contrast, reflectance increased at higher frequencies to at least 0.8 above 60 kHz. Sound pressure was also mapped in a microphone-terminated uniform tube—an “artificial ear.” Comparison with ear canal sound fields suggests that an artificial ear or “artificial cavity calibration” technique may underestimate the in situ sound pressure by 5–15 dB between 40 and 60 kHz. PMID:17902852

  16. A low phase noise microwave frequency synthesis for a high-performance cesium vapor cell atomic clock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    François, B.; Boudot, R.; Calosso, C. E.

    2014-09-15

    We report the development, absolute phase noise, and residual phase noise characterization of a 9.192 GHz microwave frequency synthesis chain devoted to be used as a local oscillator in a high-performance cesium vapor cell atomic clock based on coherent population trapping (CPT). It is based on frequency multiplication of an ultra-low phase noise 100 MHz oven-controlled quartz crystal oscillator using a nonlinear transmission line-based chain. Absolute phase noise performances of the 9.192 GHz output signal are measured to be −42, −100, −117 dB rad{sup 2}/Hz and −129 dB rad{sup 2}/Hz at 1 Hz, 100 Hz, 1 kHz, and 10 kHz offset frequencies, respectively. Comparedmore » to current results obtained in a state-of-the-art CPT-based frequency standard developed at LNE-SYRTE, this represents an improvement of 8 dB and 10 dB at f = 166 Hz and f = 10 kHz, respectively. With such performances, the expected Dick effect contribution to the atomic clock short term frequency stability is reported at a level of 6.2 × 10{sup −14} at 1 s integration time, that is a factor 3 higher than the atomic clock shot noise limit. Main limitations are pointed out.« less

  17. Acoustic perfect absorption and broadband insulation achieved by double-zero metamaterials

    NASA Astrophysics Data System (ADS)

    Wang, Xiaole; Luo, Xudong; Zhao, Hui; Huang, Zhenyu

    2018-01-01

    We report the mechanism for simultaneous realization of acoustic perfect absorption (PA) and broadband insulation (BI) in the acoustic free field by a layered acoustic metamaterial (LAM). The proposed LAM comprises two critically coupled membrane-type acoustic metamaterials sandwiching a porous material layer. Both theoretical and experimental results verify that the proposed LAM sample can achieve nearly PA (98.4% in experiments) at 312 Hz with a thickness of 15 mm (1/73 of wavelength) and BI in the frequency range of 200-1000 Hz with an areal density of 2.2 kg/m2. In addition, the real parts of both the effective dynamic density and bulk modulus reach zero precisely at the critical frequency of 312 Hz, arising from the monopolar eigenmode of LAM. Our work advances the concept of synthetic design of sound absorption and insulation properties of multi-impedance-coupled acoustic systems and promotes membrane-type acoustic metamaterials to more practical engineering applications.

  18. Local Brain Activity Differences Between Herpes Zoster and Postherpetic Neuralgia Patients: A Resting-State Functional MRI Study.

    PubMed

    Cao, Song; Li, Ying; Deng, Wenwen; Qin, Bangyong; Zhang, Yi; Xie, Peng; Yuan, Jie; Yu, Buwei; Yu, Tian

    2017-07-01

    Herpes zoster (HZ) can develop into postherpetic neuralgia (PHN), both of which are painful diseases. PHN patients suffer chronic pain and emotional disorders. Previous studies showed that the PHN brain displayed abnormal activity and structural change, but the difference in brain activity between HZ and PHN is still not known. To identify regional brain activity changes in HZ and PHN brains with resting-state functional magnetic resonance imaging (rs-fMRI) technique, and to observe the differences between HZ and PHN patients. Observational study. University hospital. Regional homogeneity (ReHo) and fractional aptitude of low-frequency fluctuation (fALFF) methods were employed to analysis resting-state brain activity. Seventy-three age and gender matched patients (50 HZ, 23 PHN) and 55 healthy controls were enrolled. ReHo and fALFF changes were analyzed to detect the functional abnormality in HZ and PHN brains. Compared with healthy controls, HZ and PHN patients exhibited abnormal ReHo and fALFF values in classic pain-related brain regions (such as the frontal lobe, thalamus, insular, and cerebellum) as well as the brainstem, limbic lobe, and temporal lobe. When HZ developed to PHN, the activity in the vast area of the cerebellum significantly increased while that of some regions in the occipital lobe, temporal lobe, parietal lobe, and limbic lobe showed an apparent decrease. (a) Relatively short pain duration (mean 12.2 months) and small sample size (n = 23) for PHN group. (b) Comparisons at different time points (with paired t-tests) for each patient may minimize individual differences. HZ and PHN induced local brain activity changed in the pain matrix, brainstem, and limbic system. HZ chronification induced functional change in the cerebellum, occipital lobe, temporal lobe, parietal lobe, and limbic lobe. These brain activity changes may be correlated with HZ-PHN transition. Herpes zoster, postherpetic neuralgia, resting-state fMRI (rs-fMRI), regional homogeneity (ReHo), fractional aptitude of low-frequency fluctuation (fALFF).

  19. Auditory steady-state response in cochlear implant patients.

    PubMed

    Torres-Fortuny, Alejandro; Arnaiz-Marquez, Isabel; Hernández-Pérez, Heivet; Eimil-Suárez, Eduardo

    2018-03-19

    Auditory steady state responses to continuous amplitude modulated tones at rates between 70 and 110Hz, have been proposed as a feasible alternative to objective frequency specific audiometry in cochlear implant subjects. The aim of the present study is to obtain physiological thresholds by means of auditory steady-state response in cochlear implant patients (Clarion HiRes 90K), with acoustic stimulation, on free field conditions and to verify its biological origin. 11 subjects comprised the sample. Four amplitude modulated tones of 500, 1000, 2000 and 4000Hz were used as stimuli, using the multiple frequency technique. The recording of auditory steady-state response was also recorded at 0dB HL of intensity, non-specific stimulus and using a masking technique. The study enabled the electrophysiological thresholds to be obtained for each subject of the explored sample. There were no auditory steady-state responses at either 0dB or non-specific stimulus recordings. It was possible to obtain the masking thresholds. A difference was identified between behavioral and electrophysiological thresholds of -6±16, -2±13, 0±22 and -8±18dB at frequencies of 500, 1000, 2000 and 4000Hz respectively. The auditory steady state response seems to be a suitable technique to evaluate the hearing threshold in cochlear implant subjects. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment

    NASA Astrophysics Data System (ADS)

    Huang, Xiaolei; Dong, Hui; Qiu, Yang; Li, Bo; Tao, Quan; Zhang, Yi; Krause, Hans-Joachim; Offenhäusser, Andreas; Xie, Xiaoming

    2018-01-01

    Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra-low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel(s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room.

  1. High-frequency oscillations mirror disease activity in patients with epilepsy.

    PubMed

    Zijlmans, M; Jacobs, J; Zelmann, R; Dubeau, F; Gotman, J

    2009-03-17

    High-frequency oscillations (HFOs) can be recorded in epileptic patients with clinical intracranial EEG. HFOs have been associated with seizure genesis because they occur in the seizure focus and during seizure onset. HFOs are also found interictally, partly co-occurring with epileptic spikes. We studied how HFOs are influenced by antiepileptic medication and seizure occurrence, to improve understanding of the pathophysiology and clinical meaning of HFOs. Intracerebral depth EEG was partly sampled at 2,000 Hz in 42 patients with intractable focal epilepsy. Patients with five or more usable nights of recording were selected. A sample of slow-wave sleep from each night was analyzed, and HFOs (ripples: 80-250 Hz, fast ripples: 250-500 Hz) and spikes were identified on all artifact-free channels. The HFOs and spikes were compared before and after seizures with stable medication dose and during medication reduction with no intervening seizures. Twelve patients with five to eight nights were included. After seizures, there was an increase in spikes, whereas HFO rates remained the same. Medication reduction was followed by an increase in HFO rates and mean duration. Contrary to spikes, high-frequency oscillations (HFOs) do not increase after seizures, but do so after medication reduction, similarly to seizures. This implies that spikes and HFOs have different pathophysiologic mechanisms and that HFOs are more tightly linked to seizures than spikes. HFOs seem to play an important role in seizure genesis and can be a useful clinical marker for disease activity.

  2. Cortical evoked potentials to an auditory illusion: binaural beats.

    PubMed

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2009-08-01

    To define brain activity corresponding to an auditory illusion of 3 and 6Hz binaural beats in 250Hz or 1000Hz base frequencies, and compare it to the sound onset response. Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000Hz to one ear and 3 or 6Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3Hz and 6Hz, in base frequencies of 250Hz and 1000Hz. Tones were 2000ms in duration and presented with approximately 1s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. All stimuli evoked tone-onset P(50), N(100) and P(200) components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P(50) had significantly different sources than the beats-evoked oscillations; and N(100) and P(200) sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp.

  3. Cortical Evoked Potentials to an Auditory Illusion: Binaural Beats

    PubMed Central

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J.; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2009-01-01

    Objective: To define brain activity corresponding to an auditory illusion of 3 and 6 Hz binaural beats in 250 Hz or 1,000 Hz base frequencies, and compare it to the sound onset response. Methods: Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000 Hz to one ear and 3 or 6 Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3 Hz and 6 Hz, in base frequencies of 250 Hz and 1000 Hz. Tones were 2,000 ms in duration and presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. Results: All stimuli evoked tone-onset P50, N100 and P200 components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P50 had significantly different sources than the beats-evoked oscillations; and N100 and P200 sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Conclusions: Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Significance: Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp. PMID:19616993

  4. High-sensitivity multifunctional spinner magnetometer using a magneto-impedance sensor

    NASA Astrophysics Data System (ADS)

    Kodama, Kazuto

    2017-01-01

    A novel spinner magnetometer was developed with a wide dynamic range from 10-10 to 10-4 Am2 and a resolution of 10-11 Am2. High sensitivity was achieved with the use of a magneto-impedance (MI) sensor, which is a compact, sensitive magnetic sensor used industrially. Its slow-spinning rate (5 Hz) and the incorporation of a unique mechanism for adjusting the spacing between the sensing unit and the spinning axis allows the measurement of fragile samples sized 10-50 mm. The sensor configuration, in which a pair of MI sensors is connected in opposite serial, along with an amplification circuit with a programmable low-pass filter, reduces the problems of external noise and sensor drift. The signal, with reference to the spinning frequency, is detected with a lock-in amplifier. The MI spinner has two selectable measurement modes: the fundamental mode (F mode) and the harmonic mode (H mode). Measurements in the F mode detect signals of the fundamental frequency (5 Hz), in the same way as conventional spinner magnetometers. In the H mode, the second (10 Hz) and the third (15 Hz) harmonic components are measured, in addition to the fundamental component. Tests in the H mode were performed using a small coil and a natural sample to simulate dipoles with various degrees of offset. The results revealed that the magnitude of the fundamental component of the offset dipole was systematically larger (by several percent) than that of the nonoffset dipole. These findings suggest that this novel MI spinner will be useful in estimating the inhomogeneity of the magnetization of a sample that can equivalently be described by an offset dipole.

  5. The JET diagnostic fast central acquisition and trigger system (abstract)

    NASA Astrophysics Data System (ADS)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  6. 47 CFR 90.173 - Policies governing the assignment of frequencies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...

  7. 47 CFR 90.173 - Policies governing the assignment of frequencies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...

  8. 47 CFR 90.173 - Policies governing the assignment of frequencies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...

  9. 47 CFR 90.173 - Policies governing the assignment of frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...

  10. 47 CFR 90.173 - Policies governing the assignment of frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for stations in the 150-174 MHz and 421-512 MHz bands for operation on frequencies 15 kHz or less... frequencies that were available prior to August 18, 1995 will be granted with channel bandwidths of 25 kHz or... 12.5 kHz or less (i.e., in the Public Safety Pool, frequencies subject to §§ 90.20 (d)(27) and (d)(44...

  11. High frequency testing of rubber mounts.

    PubMed

    Vahdati, Nader; Saunders, L Ken Lauderbaugh

    2002-04-01

    Rubber and fluid-filled rubber engine mounts are commonly used in automotive and aerospace applications to provide reduced cabin noise and vibration, and/or motion accommodations. In certain applications, the rubber mount may operate at frequencies as high as 5000 Hz. Therefore, dynamic stiffness of the mount needs to be known in this frequency range. Commercial high frequency test machines are practically nonexistent, and the best high frequency test machine on the market is only capable of frequencies as high as 1000 Hz. In this paper, a high frequency test machine is described that allows test engineers to study the high frequency performance of rubber mounts at frequencies up to 5000 Hz.

  12. Investigation of the Relationship Between Electrical Stimulation Frequency and Muscle Frequency Response Under Submaximal Contractions.

    PubMed

    Papcke, Caluê; Krueger, Eddy; Olandoski, Marcia; Nogueira-Neto, Guilherme Nunes; Nohama, Percy; Scheeren, Eduardo Mendonça

    2018-03-25

    Neuromuscular electrical stimulation (NMES) is a common tool that is used in clinical and laboratory experiments and can be combined with mechanomyography (MMG) for biofeedback in neuroprostheses. However, it is not clear if the electrical current applied to neuromuscular tissues influences the MMG signal in submaximal contractions. The objective of this study is to investigate whether the electrical stimulation frequency influences the mechanomyographic frequency response of the rectus femoris muscle during submaximal contractions. Thirteen male participants performed three maximal voluntary isometric contractions (MVIC) recorded in isometric conditions to determine the maximal force of knee extensors. This was followed by the application of nine modulated NMES frequencies (20, 25, 30, 35, 40, 45, 50, 75, and 100 Hz) to evoke 5% MVIC. Muscle behavior was monitored by the analysis of MMG signals, which were decomposed into frequency bands by using a Cauchy wavelet transform. For each applied electrical stimulus frequency, the mean MMG spectral/frequency response was estimated for each axis (X, Y, and Z axes) of the MMG sensor with the values of the frequency bands used as weights (weighted mean). Only with respect to the Z (perpendicular) axis of the MMG signal, the stimulus frequency of 20 Hz did not exhibit any difference with the weighted mean (P = 0.666). For the frequencies of 20 and 25 Hz, the MMG signal displayed the bands between 12 and 16 Hz in the three axes (P < 0.050). In the frequencies from 30 to 100 Hz, the muscle presented a higher concentration of the MMG signal between the 22 and 29 Hz bands for the X and Z axes, and between 16 and 34 Hz bands for the Y axis (P < 0.050 for all cases). We observed that MMG signals are not dependent on the applied NMES frequency, because their frequency contents tend to mainly remain between the 20- and 25-Hz bands. Hence, NMES does not interfere with the use of MMG in neuroprosthesis. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. HVSR Response Evolution due to Seasonal Variation: Observations from 2 Years of Continuous Monitoring

    NASA Astrophysics Data System (ADS)

    Nurse, K. B.; Milkereit, B.

    2017-12-01

    The seismic Horizontal to Vertical Spectral Ratio analysis technique reliably gives overburden depth to bedrock, for an independently determined Vs, based on the frequency of the main resonance peak. Above this, smaller resonances reflect the velocity structure within the overburden itself. This range in the HVSR response shows sufficient sensitivity to be exploited as a monitoring tool, to detect change in seismic physical properties and from that, change in overburden conditions. To explore the variation of the response, several 3C geophones have been deployed in southern Ontario, Canada since December 2015 (and ongoing). The local geology is a sedimentary basin with 30m of overburden, a simple 2D environment well suited for the HVSR method. Data are collected for 15s per minute, with an effective frequency band of 2-400Hz. HVSR estimates are produced for each sampling period and archived. Over these two years, winter freeze/thaw, saturated spring and summer draught conditions were sampled. H/V daily averages are dominated by the stable 3Hz resonance due to the overall surface layer, but smaller spectral peaks up to 100Hz are clear and evolve in frequency and amplitude over the collection period. Ground freeze/thaw cycles are clearly evident by significant reduction in the horizontal field, but also the changing of the soil moisture content throughout the year causes subtle shifts in the response (correlated to rain events and water table variation). The long term sampling does show a sensitivity of the HVSR method to the overburden in proximity to the sensor, and suggests a possibility for its use in monitoring soil / water-table conditions. But it also highlights that the estimate from an isolated H/V acquisition does include this variability and needs to be adequately quantified in VS30 estimates.

  14. Investigating mechanically induced phase response of the tissue by using high-speed phase-resolved optical coherence tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ling, Yuye; Hendon, Christine P.

    2017-02-01

    Phase-resolved optical coherence tomography (OCT), a functional extension of OCT, provides depth-resolved phase information with extra contrast. In cardiology, changes in the mechanical properties have been associated with tissue remodeling and disease progression. Here we present the capability of profiling structural deformation of the sample in vivo by using a highly stable swept source OCT system The system, operating at 1300 nm, has an A-line acquisition rate of 200 kHz. We measured the phase noise floor to be 6.5 pm±3.2 pm by placing a cover slip in the sample arm, while blocking the reference arm. We then conducted a vibrational frequency test by measuring the phase response from a polymer membrane stimulated by a pure tone acoustic wave from 10 kHz to 80 kHz. The measured frequency response agreed with the known stimulation frequency with an error < 0.005%. We further measured the phase response of 7 fresh swine hearts obtained from Green Village Packing Company through a mechanical stretching test, within 24 hours of sacrifice. The heart tissue was cut into a 1 mm slices and fixed on two motorized stages. We acquired 100,000 consecutive M-scans, while the sample is stretched at a constant velocity of 10 um/s. The depth-resolved phase image presents linear phase response over time at each depth, but the slope varies among tissue types. Our future work includes refining our experiment protocol to quantitatively measured the elastic modulus of the tissue in vivo and building a tissue classifier based on depth-resolved phase information.

  15. Improved supervised classification of accelerometry data to distinguish behaviors of soaring birds.

    PubMed

    Sur, Maitreyi; Suffredini, Tony; Wessells, Stephen M; Bloom, Peter H; Lanzone, Michael; Blackshire, Sheldon; Sridhar, Srisarguru; Katzner, Todd

    2017-01-01

    Soaring birds can balance the energetic costs of movement by switching between flapping, soaring and gliding flight. Accelerometers can allow quantification of flight behavior and thus a context to interpret these energetic costs. However, models to interpret accelerometry data are still being developed, rarely trained with supervised datasets, and difficult to apply. We collected accelerometry data at 140Hz from a trained golden eagle (Aquila chrysaetos) whose flight we recorded with video that we used to characterize behavior. We applied two forms of supervised classifications, random forest (RF) models and K-nearest neighbor (KNN) models. The KNN model was substantially easier to implement than the RF approach but both were highly accurate in classifying basic behaviors such as flapping (85.5% and 83.6% accurate, respectively), soaring (92.8% and 87.6%) and sitting (84.1% and 88.9%) with overall accuracies of 86.6% and 92.3% respectively. More detailed classification schemes, with specific behaviors such as banking and straight flights were well classified only by the KNN model (91.24% accurate; RF = 61.64% accurate). The RF model maintained its accuracy of classifying basic behavior classification accuracy of basic behaviors at sampling frequencies as low as 10Hz, the KNN at sampling frequencies as low as 20Hz. Classification of accelerometer data collected from free ranging birds demonstrated a strong dependence of predicted behavior on the type of classification model used. Our analyses demonstrate the consequence of different approaches to classification of accelerometry data, the potential to optimize classification algorithms with validated flight behaviors to improve classification accuracy, ideal sampling frequencies for different classification algorithms, and a number of ways to improve commonly used analytical techniques and best practices for classification of accelerometry data.

  16. Improved supervised classification of accelerometry data to distinguish behaviors of soaring birds

    PubMed Central

    Suffredini, Tony; Wessells, Stephen M.; Bloom, Peter H.; Lanzone, Michael; Blackshire, Sheldon; Sridhar, Srisarguru; Katzner, Todd

    2017-01-01

    Soaring birds can balance the energetic costs of movement by switching between flapping, soaring and gliding flight. Accelerometers can allow quantification of flight behavior and thus a context to interpret these energetic costs. However, models to interpret accelerometry data are still being developed, rarely trained with supervised datasets, and difficult to apply. We collected accelerometry data at 140Hz from a trained golden eagle (Aquila chrysaetos) whose flight we recorded with video that we used to characterize behavior. We applied two forms of supervised classifications, random forest (RF) models and K-nearest neighbor (KNN) models. The KNN model was substantially easier to implement than the RF approach but both were highly accurate in classifying basic behaviors such as flapping (85.5% and 83.6% accurate, respectively), soaring (92.8% and 87.6%) and sitting (84.1% and 88.9%) with overall accuracies of 86.6% and 92.3% respectively. More detailed classification schemes, with specific behaviors such as banking and straight flights were well classified only by the KNN model (91.24% accurate; RF = 61.64% accurate). The RF model maintained its accuracy of classifying basic behavior classification accuracy of basic behaviors at sampling frequencies as low as 10Hz, the KNN at sampling frequencies as low as 20Hz. Classification of accelerometer data collected from free ranging birds demonstrated a strong dependence of predicted behavior on the type of classification model used. Our analyses demonstrate the consequence of different approaches to classification of accelerometry data, the potential to optimize classification algorithms with validated flight behaviors to improve classification accuracy, ideal sampling frequencies for different classification algorithms, and a number of ways to improve commonly used analytical techniques and best practices for classification of accelerometry data. PMID:28403159

  17. Improved supervised classification of accelerometry data to distinguish behaviors of soaring birds

    USGS Publications Warehouse

    Sur, Maitreyi; Suffredini, Tony; Wessells, Stephen M.; Bloom, Peter H.; Lanzone, Michael J.; Blackshire, Sheldon; Sridhar, Srisarguru; Katzner, Todd

    2017-01-01

    Soaring birds can balance the energetic costs of movement by switching between flapping, soaring and gliding flight. Accelerometers can allow quantification of flight behavior and thus a context to interpret these energetic costs. However, models to interpret accelerometry data are still being developed, rarely trained with supervised datasets, and difficult to apply. We collected accelerometry data at 140Hz from a trained golden eagle (Aquila chrysaetos) whose flight we recorded with video that we used to characterize behavior. We applied two forms of supervised classifications, random forest (RF) models and K-nearest neighbor (KNN) models. The KNN model was substantially easier to implement than the RF approach but both were highly accurate in classifying basic behaviors such as flapping (85.5% and 83.6% accurate, respectively), soaring (92.8% and 87.6%) and sitting (84.1% and 88.9%) with overall accuracies of 86.6% and 92.3% respectively. More detailed classification schemes, with specific behaviors such as banking and straight flights were well classified only by the KNN model (91.24% accurate; RF = 61.64% accurate). The RF model maintained its accuracy of classifying basic behavior classification accuracy of basic behaviors at sampling frequencies as low as 10Hz, the KNN at sampling frequencies as low as 20Hz. Classification of accelerometer data collected from free ranging birds demonstrated a strong dependence of predicted behavior on the type of classification model used. Our analyses demonstrate the consequence of different approaches to classification of accelerometry data, the potential to optimize classification algorithms with validated flight behaviors to improve classification accuracy, ideal sampling frequencies for different classification algorithms, and a number of ways to improve commonly used analytical techniques and best practices for classification of accelerometry data.

  18. 47 CFR 90.242 - Travelers' information stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the modulation limiter and the modulated stage. At audio frequencies between 3 kHz and 20 kHz this...' information stations. (a) The frequencies 530 through 1700 kHz in 10 kHz increments may be assigned to the... consideration of possible cross-modulation and inter-modulation interference effects which may result from the...

  19. Audiogram of a striped dolphin (Stenella coeruleoalba)

    NASA Astrophysics Data System (ADS)

    Kastelein, Ronald A.; Hagedoorn, Monique; Au, Whitlow W. L.; de Haan, Dick

    2003-02-01

    The underwater hearing sensitivity of a striped dolphin was measured in a pool using standard psycho-acoustic techniques. The go/no-go response paradigm and up-down staircase psychometric method were used. Auditory sensitivity was measured by using 12 narrow-band frequency-modulated signals having center frequencies between 0.5 and 160 kHz. The 50% detection threshold was determined for each frequency. The resulting audiogram for this animal was U-shaped, with hearing capabilities from 0.5 to 160 kHz (8 13 oct). Maximum sensitivity (42 dB re 1 μPa) occurred at 64 kHz. The range of most sensitive hearing (defined as the frequency range with sensitivities within 10 dB of maximum sensitivity) was from 29 to 123 kHz (approximately 2 oct). The animal's hearing became less sensitive below 32 kHz and above 120 kHz. Sensitivity decreased by about 8 dB per octave below 1 kHz and fell sharply at a rate of about 390 dB per octave above 140 kHz.

  20. Application of IDT Sensors for Structural Health Monitoring of Windmill Turbine Blades Made of Composite Material

    NASA Astrophysics Data System (ADS)

    Nalladega, V.; Na, J. K.; Druffner, C.

    2011-06-01

    Interdigital transducers (IDT) generate and receive ultrasonic surface waves without the complexity involved with secondary devices such as angled wedges or combs. The IDT sensors have been successfully applied for the NDE of homogeneous materials like metals in order to detect cracks and de-bond. However, these transducers have not been yet adapted for complex and anisotropic materials like fiber-reinforced composites. This work presents the possibility of using IDT sensors for monitoring structural damages in wind turbine blades, typically made of fiberglass composites. IDT sensors with a range of operating frequency between 250 kHz and 1 MHz are initially tested on representative composite test panels for ultrasonic surface wave properties including beam spread, propagation distance and effect of material's anisotropy. Based on these results, an optimum frequency range for the IDT sensor is found to be 250-500 kHz. Subsequently, IDT sensors with operating frequency 500 kHz are used to detect and quantify artificial defects created in the composite test samples. Discussions are made on the interaction of ultrasonic fields with these defects along with the effects of fiber directionality and composite layer stacking.

  1. Characterization of a vertically movable gate field effect transistor using a silicon-on-insulator wafer

    NASA Astrophysics Data System (ADS)

    Song, In-Hyouk; Forfang, William B. D.; Cole, Bryan; You, Byoung Hee

    2014-10-01

    The vertically movable gate field effect transistor (VMGFET) is a FET-based sensing element, whose gate moves in a vertical direction over the channel. A VMGFET gate covers the region between source and drain. A 1 μm thick air layer separates the gate and the substrate of the VMGFET. A novel fabrication process to form a VMGFET using a silicon-on-insulator (SOI) wafer provides minimal internal stress of the gate structure. The enhancement-type n-channel VMGFET is fabricated with the threshold voltage of 2.32 V in steady state. A non-inverting amplifier is designed and integrated on a printable circuit board (PCB) to characterize device sensitivity and mechanical properties. The VMGFET is mechanically coupled to a speaker membrane to apply mechanical vibration. The oscillated drain current of FET are monitored and sampled with NI LabVIEW. The frequency of the output signal correlates with that of the input stimulus. The resonance frequency of the fabricated VMGFET is measured to be 1.11 kHz. The device sensitivity linearly increases by 0.106 mV/g Hz in the range of 150 Hz and 1 kHz.

  2. Effect of pulsed electric field on the proteolysis of cold boned beef M. Longissimus lumborum and M. Semimembranosus.

    PubMed

    Suwandy, Via; Carne, Alan; van de Ven, Remy; Bekhit, Alaa El-Din A; Hopkins, David L

    2015-02-01

    The effects of pulsed electric field (PEF) and ageing (3, 7, 14 and 21 days) on the shear force, protein profile, and post-mortem proteolysis of beef loins (M. Longissimus lumborum, LL) and topsides (M. Semimembranosus, SM) were investigated using a range of pulsed electric field treatments [voltages (5 and 10 kV) and frequencies (20, 50, and 90 Hz)]. PEF treatment decreased the shear force of beef LL and SM muscles by up to 19%. The reduction in the shear force in the LL was not affected by the treatment intensity whereas the reduction in the SM was dependent on PEF frequency. PEF treated beef loins showed increased proteolysis, both early post-mortem and during subsequent post-mortem storage reflected by increased degradation of troponin-T and desmin. The most prominent troponin-T degradation was found in samples treated with 5 kV-90 Hz, 10 kV-20 Hz at day 3 and day 7 post-treatment in addition to 10 kV-50 Hz in subsequent post-treatment times. The degradation of desmin in PEF treated beef loins increased with ageing time.

  3. Characterisation of the human-seat coupling in response to vibration.

    PubMed

    Kim, Eunyeong; Fard, Mohammad; Kato, Kazuhito

    2017-08-01

    Characterising the coupling between the occupant and vehicle seat is necessary to understand the transmission of vehicle seat vibration to the human body. In this study, the vibration characteristics of the human body coupled with a vehicle seat were identified in frequencies up to 100 Hz. Transmissibilities of three volunteers seated on two different vehicle seats were measured under multi-axial random vibration excitation. The results revealed that the human-seat system vibration was dominated by the human body and foam below 10 Hz. Major coupling between the human body and the vehicle seat-structure was observed in the frequency range of 10-60 Hz. There was local coupling of the system dominated by local resonances of seat frame and seat surface above 60 Hz. Moreover, the transmissibility measured on the seat surface between the human and seat foam is suggested to be a good method of capturing human-seat system resonances rather than that measured on the human body in high frequencies above 10 Hz.Practitioner Summary: The coupling characteristics of the combined human body and vehicle seat system has not yet been fully understood in frequencies of 0.5-100 Hz. This study shows the human-seat system has distinctive dynamic coupling characteristics in three different frequency regions: below 10 Hz, 10-60 Hz, and above 60 Hz.

  4. Very Low Frequency Breakdown Properties of Electrical Insulation Materials at Cryogenic Temperatures

    NASA Astrophysics Data System (ADS)

    Sauers, I.; Tuncer, E.; Polizos, G.; James, D. R.; Ellis, A. R.; Pace, M. O.

    2010-04-01

    For long cables or equipment with large capacitance it is not always possible to conduct high voltage withstand tests at 60 Hz due to limitations in charging currents of the power supply. Very low frequency (typically at a frequency of 0.1 Hz) has been used for conventional cables as a way of getting around the charging current limitation. For superconducting grid applications the same issues apply. However there is very little data at cryogenic temperatures on how materials perform at low frequency compared to 60 Hz and whether higher voltages should be applied when performing a high voltage acceptability test. Various materials including G10 (fiberglass reinforced plastic or FRP), Cryoflex™ (a tape insulation used in some high temperature superconducting cables), kapton (commonly used polyimide), polycarbonate, and polyetherimide, and in liquid nitrogen alone have been tested using a step method for frequencies of 60 Hz, 0.1 Hz, and dc. The dwell time at each step was chosen so that the aging factor would be the same in both the 60 Hz and 0.1 Hz tests. The data indicated that, while there is a small frequency dependence for liquid nitrogen, there are significant differences for the solid materials studied. Breakdown data for these materials and for model cables will be shown and discussed.

  5. [Comparison of tone burst evoked auditory brainstem responses with different filter settings for referral infants after hearing screening].

    PubMed

    Diao, Wen-wen; Ni, Dao-feng; Li, Feng-rong; Shang, Ying-ying

    2011-03-01

    Auditory brainstem responses (ABR) evoked by tone burst is an important method of hearing assessment in referral infants after hearing screening. The present study was to compare the thresholds of tone burst ABR with filter settings of 30 - 1500 Hz and 30 - 3000 Hz at each frequency, figure out the characteristics of ABR thresholds with the two filter settings and the effect of the waveform judgement, so as to select a more optimal frequency specific ABR test parameter. Thresholds with filter settings of 30 - 1500 Hz and 30 - 3000 Hz in children aged 2 - 33 months were recorded by click, tone burst ABR. A total of 18 patients (8 male/10 female), 22 ears were included. The thresholds of tone burst ABR with filter settings of 30 - 3000 Hz were higher than that with filter settings of 30 - 1500 Hz. Significant difference was detected for that at 0.5 kHz and 2.0 kHz (t values were 2.238 and 2.217, P < 0.05), no significant difference between the two filter settings was detected at the rest frequencies tone evoked ABR thresholds. The waveform of ABR with filter settings of 30 - 1500 Hz was smoother than that with filter settings of 30 - 3000 Hz at the same stimulus intensity. Response curve of the latter appeared jagged small interfering wave. The filter setting of 30 - 1500 Hz may be a more optimal parameter of frequency specific ABR to improve the accuracy of frequency specificity ABR for infants' hearing assessment.

  6. Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium.

    PubMed

    Yang, Liju; Li, Yanbin; Griffis, Carl L; Johnson, Michael G

    2004-05-15

    Interdigitated microelectrodes (IMEs) were used as impedance sensors for rapid detection of viable Salmonella typhimurium in a selective medium and milk samples. The impedance growth curves, impedance against bacterial growth time, were recorded at four frequencies (10Hz, 100Hz, 1kHz, and 10kHz) during the growth of S. typhimurium. The impedance did not change until the cell number reached 10(5)-10(6) CFUml(-1). The greatest change in impedance was observed at 10Hz. To better understand the mechanism of the IME impedance sensor, an equivalent electrical circuit, consisting of double layer capacitors, a dielectric capacitor, and a medium resistor, was introduced and used for interpreting the change in impedance during bacterial growth. Bacterial attachment to the electrode surface was observed with scanning electron microscopy, and it had effect on the impedance measurement. The detection time, t(D), defined as the time for the impedance to start change, was obtained from the impedance growth curve at 10Hz and had a linear relationship with the logarithmic value of the initial cell number of S. typhimurium in the medium and milk samples. The regression equations for the cell numbers between 4.8 and 5.4 x 10(5) CFUml(-1) were t(D) = -1.38 log N + 10.18 with R(2) = 0.99 in the pure medium and t(D) = -1.54 log N + 11.33 with R(2) = 0.98 in milk samples, respectively. The detection times for 4.8 and 5.4 x 10(5) CFUml(-1) initial cell numbers were 9.3 and 2.2 h, respectively, and the detection limit could be as low as 1 cell in a sample.

  7. Superburst oscillations: ocean and crustal modes excited by carbon-triggered type I X-ray bursts

    NASA Astrophysics Data System (ADS)

    Chambers, F. R. N.; Watts, A. L.; Cavecchi, Y.; Garcia, F.; Keek, L.

    2018-07-01

    Accreting neutron stars (NS) can exhibit high frequency modulations in their light curves during thermonuclear X-ray bursts, known as burst oscillations. The frequencies can be offset from the spin frequency of the NS by several Hz, and can drift by 1-3 Hz. One possible explanation is a mode in the bursting ocean, the frequency of which would decrease (in the rotating frame) as the burst cools, hence explaining the drifts. Most burst oscillations have been observed during the H/He-triggered bursts; however there has been one observation of oscillations during a superburst; hours long Type I X-ray bursts caused by unstable carbon burning deeper in the ocean. This paper calculates the frequency evolution of an oceanic r mode during a superburst. The rotating frame frequency varies during the burst from 4-14 Hz and is sensitive to the background parameters, in particular the temperature of the ocean and ignition depth. This calculation is compared to the superburst oscillations observed on 4U-1636-536. The predicted mode frequencies (˜10 Hz) would require a spin frequency of ˜592 Hz to match observations; 6 Hz higher than the spin inferred from an oceanic r-mode model for the H/He-triggered burst oscillations. This model also overpredicts the frequency drift during the superburst by 90 per cent.

  8. Frequencies of inaudible high-frequency sounds differentially affect brain activity: positive and negative hypersonic effects.

    PubMed

    Fukushima, Ariko; Yagi, Reiko; Kawai, Norie; Honda, Manabu; Nishina, Emi; Oohashi, Tsutomu

    2014-01-01

    The hypersonic effect is a phenomenon in which sounds containing significant quantities of non-stationary high-frequency components (HFCs) above the human audible range (max. 20 kHz) activate the midbrain and diencephalon and evoke various physiological, psychological and behavioral responses. Yet important issues remain unverified, especially the relationship existing between the frequency of HFCs and the emergence of the hypersonic effect. In this study, to investigate the relationship between the hypersonic effect and HFC frequencies, we divided an HFC (above 16 kHz) of recorded gamelan music into 12 band components and applied them to subjects along with an audible component (below 16 kHz) to observe changes in the alpha2 frequency component (10-13 Hz) of spontaneous EEGs measured from centro-parieto-occipital regions (Alpha-2 EEG), which we previously reported as an index of the hypersonic effect. Our results showed reciprocal directional changes in Alpha-2 EEGs depending on the frequency of the HFCs presented with audible low-frequency component (LFC). When an HFC above approximately 32 kHz was applied, Alpha-2 EEG increased significantly compared to when only audible sound was applied (positive hypersonic effect), while, when an HFC below approximately 32 kHz was applied, the Alpha-2 EEG decreased (negative hypersonic effect). These findings suggest that the emergence of the hypersonic effect depends on the frequencies of inaudible HFC.

  9. Superburst oscillations: ocean and crustal modes excited by Carbon-triggered Type I X-ray bursts

    NASA Astrophysics Data System (ADS)

    Chambers, F. R. N.; Watts, A. L.; Cavecchi, Y.; Garcia, F.; Keek, L.

    2018-04-01

    Accreting neutron stars (NS) can exhibit high frequency modulations in their lightcurves during thermonuclear X-ray bursts, known as burst oscillations. The frequencies can be offset from the spin frequency of the NS by several Hz, and can drift by 1-3 Hz. One possible explanation is a mode in the bursting ocean, the frequency of which would decrease (in the rotating frame) as the burst cools, hence explaining the drifts. Most burst oscillations have been observed during H/He triggered bursts, however there has been one observation of oscillations during a superburst; hours' long Type I X-ray bursts caused by unstable carbon burning deeper in the ocean. This paper calculates the frequency evolution of an oceanic r-mode during a superburst. The rotating frame frequency varies during the burst from 4 - 14 Hz, and is sensitive to the background parameters, in particular the temperature of the ocean and ignition depth. This calculation is compared to the superburst oscillations observed on 4U-1636-536. The predicted mode frequencies (˜10 Hz) would require a spin frequency of ˜592 Hz to match observations; 6 Hz higher than the spin inferred from an oceanic r-mode model for the H/He triggered burst oscillations. This model also over-predicts the frequency drift during the superburst by 90%.

  10. Effects of different frequencies of transcutaneous electrical nerve stimulation on venous vascular reactivity

    PubMed Central

    Franco, O.S.; Paulitsch, F.S.; Pereira, A.P.C.; Teixeira, A.O.; Martins, C.N.; Silva, A.M.V.; Plentz, R.D.M.; Irigoyen, M.C.; Signori, L.U.

    2014-01-01

    Transcutaneous electrical nerve stimulation (TENS) is a type of therapy used primarily for analgesia, but also presents changes in the cardiovascular system responses; its effects are dependent upon application parameters. Alterations to the cardiovascular system suggest that TENS may modify venous vascular response. The objective of this study was to evaluate the effects of TENS at different frequencies (10 and 100 Hz) on venous vascular reactivity in healthy subjects. Twenty-nine healthy male volunteers were randomized into three groups: placebo (n=10), low-frequency TENS (10 Hz, n=9) and high-frequency TENS (100 Hz, n=10). TENS was applied for 30 min in the nervous plexus trajectory from the superior member (from cervical to dorsal region of the fist) at low (10 Hz/200 μs) and high frequency (100 Hz/200 μs) with its intensity adjusted below the motor threshold and intensified every 5 min, intending to avoid accommodation. Venous vascular reactivity in response to phenylephrine, acetylcholine (endothelium-dependent) and sodium nitroprusside (endothelium-independent) was assessed by the dorsal hand vein technique. The phenylephrine effective dose to achieve 70% vasoconstriction was reduced 53% (P<0.01) using low-frequency TENS (10 Hz), while in high-frequency stimulation (100 Hz), a 47% increased dose was needed (P<0.01). The endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) responses were not modified by TENS, which modifies venous responsiveness, and increases the low-frequency sensitivity of α1-adrenergic receptors and shows high-frequency opposite effects. These changes represent an important vascular effect caused by TENS with implications for hemodynamics, inflammation and analgesia. PMID:24820225

  11. Altered Cortical Activation in Adolescents With Acute Migraine: A Magnetoencephalography Study

    PubMed Central

    Xiang, Jing; deGrauw, Xinyao; Korostenskaja, Milena; Korman, Abraham M.; O’Brien, Hope L.; Kabbouche, Marielle A.; Powers, Scott W.; Hershey, Andrew D.

    2013-01-01

    To quantitatively assess cortical dysfunction in pediatric migraine, 31 adolescents with acute migraine and age- and gender-matched controls were studied using a magnetoencephalography (MEG) system at a sampling rate of 6,000 Hz. Neuromagnetic brain activation was elicited by a finger-tapping task. The spectral and spatial signatures of magnetoencephalography data in 5 to 2,884 Hz were analyzed using Morlet wavelet and beamformers. Compared with controls, 31 migraine subjects during their headache attack phases (ictal) showed significantly prolonged latencies of neuromagnetic activation in 5 to 30 Hz, increased spectral power in 100 to 200 Hz, and a higher likelihood of neuromagnetic activation in the supplementary motor area, the occipital and ipsilateral sensorimotor cortices, in 2,200 to 2,800 Hz. Of the 31 migraine subjects, 16 migraine subjects during their headache-free phases (interictal) showed that there were no significant differences between interictal and control MEG data except that interictal spectral power in 100 to 200 Hz was significantly decreased. The results demonstrated that migraine subjects had significantly aberrant ictal brain activation, which can normalize interictally. The spread of abnormal ictal brain activation in both low- and high-frequency ranges triggered by movements may play a key role in the cascade of migraine attacks. Perspective This is the first study focusing on the spectral and spatial signatures of cortical dysfunction in adolescents with migraine using MEG signals in a frequency range of 5 to 2,884 Hz. This analyzing aberrant brain activation may be important for developing new therapeutic interventions for migraine in the future. PMID:23792072

  12. Graphene earphones: entertainment for both humans and animals.

    PubMed

    Tian, He; Li, Cheng; Mohammad, Mohammad Ali; Cui, Ya-Long; Mi, Wen-Tian; Yang, Yi; Xie, Dan; Ren, Tian-Ling

    2014-06-24

    The human hearing range is from 20 Hz to 20 kHz. However, many animals can hear much higher sound frequencies. Dolphins, especially, have a hearing range up to 300 kHz. To our knowledge, there is no data of a reported wide-band sound frequency earphone to satisfy both humans and animals. Here, we show that graphene earphones, packaged into commercial earphone casings can play sounds ranging from 100 Hz to 50 kHz. By using a one-step laser scribing technology, wafer-scale flexible graphene earphones can be obtained in 25 min. Compared with a normal commercial earphone, the graphene earphone has a wider frequency response (100 Hz to 50 kHz) and a three times lower fluctuation (±10 dB). A nonlinear effect exists in the graphene-generated sound frequency spectrum. This effect could be explained by the DC bias added to the input sine waves which may induce higher harmonics. Our numerical calculations show that the sound frequency emitted by graphene could reach up to 1 MHz. In addition, we have demonstrated that a dog wearing a graphene earphone could also be trained and controlled by 35 kHz sound waves. Our results show that graphene could be widely used to produce earphones for both humans and animals.

  13. Comparison between ABR with click and narrow band chirp stimuli in children.

    PubMed

    Zirn, Stefan; Louza, Julia; Reiman, Viktor; Wittlinger, Natalie; Hempel, John-Martin; Schuster, Maria

    2014-08-01

    Click and chirp-evoked auditory brainstem responses (ABR) are applied for the estimation of hearing thresholds in children. The present study analyzes ABR thresholds across a large sample of children's ears obtained with both methods. The aim was to demonstrate the correlation between both methods using narrow band chirp and click stimuli. Click and chirp evoked ABRs were measured in 253 children aged from 0 to 18 years to determine their individual auditory threshold. The delay-compensated stimuli were narrow band CE chirps with either 2000 Hz or 4000 Hz center frequencies. Measurements were performed consecutively during natural sleep, and under sedation or general anesthesia. Threshold estimation was performed for each measurement by two experienced audiologists. Pearson-correlation analysis revealed highly significant correlations (r=0.94) between click and chirp derived thresholds for both 2 kHz and 4 kHz chirps. No considerable differences were observed either between different age ranges or gender. Comparing the thresholds estimated using ABR with click stimuli and chirp stimuli, only 0.8-2% for the 2000 Hz NB-chirp and 0.4-1.2% of the 4000 Hz NB-chirp measurements differed more than 15 dB for different degrees of hearing loss or normal hearing. The results suggest that either NB-chirp or click ABR is sufficient for threshold estimation. This holds for the chirp frequencies of 2000 Hz and 4000 Hz. The use of either click- or chirp-evoked ABR allows a reduction of recording time in young infants. Nevertheless, to cross-check the results of one of the methods, we recommend measurements with the other method as well. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Relationship between blood pressure and cerebral blood flow during supine cycling: influence of aging

    PubMed Central

    Hoffman, Keegan; Tzeng, Yu-Chieh; Hansen, Alex; Ainslie, Philip N.

    2015-01-01

    The cerebral pressure-flow relationship can be quantified as a high-pass filter, where slow oscillations are buffered (<0.20 Hz) and faster oscillations are passed through relatively unimpeded. During moderate intensity exercise, previous studies have reported paradoxical transfer function analysis (TFA) findings (altered phase or intact gain). This study aimed to determine whether these previous findings accurately represent this relationship. Both younger (20–30 yr; n = 10) and older (62–72 yr; n = 9) adults were examined. To enhance the signal-to-noise ratio, large oscillations in blood pressure (via oscillatory lower body negative pressure; OLBNP) were induced during steady-state moderate intensity supine exercise (∼45–50% of heart rate reserve). Beat-to-beat blood pressure, cerebral blood velocity, and end-tidal Pco2 were monitored. Very low frequency (0.02–0.07 Hz) and low frequency (0.07–0.20 Hz) range spontaneous data were quantified. Driven OLBNP point estimates were sampled at 0.05 and 0.10 Hz. The OLBNP maneuvers augmented coherence to >0.97 at 0.05 Hz and >0.98 at 0.10 Hz in both age groups. The OLBNP protocol conclusively revealed the cerebrovascular system functions as a high-pass filter during exercise throughout aging. It was also discovered that the older adults had elevations (+71%) in normalized gain (+0.46 ± 0.36%/%: 0.05 Hz) and reductions (−34%) in phase (−0.24 ± 0.22 radian: 0.10 Hz). There were also age-related phase differences between resting and exercise conditions. It is speculated that these age-related changes in the TFA metrics are mediated by alterations in vasoactive factors, sympathetic tone, or the mechanical buffering of the compliance vessels. PMID:26586907

  15. Frequency Responses of Rat Retinal Ganglion Cells

    PubMed Central

    Cloherty, Shaun L.; Hung, Yu-Shan; Kameneva, Tatiana; Ibbotson, Michael R.

    2016-01-01

    There are 15–20 different types of retinal ganglion cells (RGC) in the mammalian retina, each encoding different aspects of the visual scene. The mechanism by which post-synaptic signals from the retinal network generate spikes is determined by each cell’s intrinsic electrical properties. Here we investigate the frequency responses of morphologically identified rat RGCs using intracellular injection of sinusoidal current waveforms, to assess their intrinsic capabilities with minimal contributions from the retinal network. Recorded cells were classified according to their morphological characteristics (A, B, C or D-type) and their stratification (inner (i), outer (o) or bistratified) in the inner plexiform layer (IPL). Most cell types had low- or band-pass frequency responses. A2, C1 and C4o cells were band-pass with peaks of 15–30 Hz and low-pass cutoffs above 56 Hz (A2 cells) and ~42 Hz (C1 and C4o cells). A1 and C2i/o cells were low-pass with peaks of 10–15 Hz (cutoffs 19–25 Hz). Bistratified D1 and D2 cells were also low-pass with peaks of 5–10 Hz (cutoffs ~16 Hz). The least responsive cells were the B2 and C3 types (peaks: 2–5 Hz, cutoffs: 8–11 Hz). We found no difference between cells stratifying in the inner and outer IPL (i.e., ON and OFF cells) or between cells with large and small somas or dendritic fields. Intrinsic physiological properties (input resistance, spike width and sag) had little impact on frequency response at low frequencies, but account for 30–40% of response variability at frequencies >30 Hz. PMID:27341669

  16. Wideband profiles of stimulus-frequency otoacoustic emissions in humans

    NASA Astrophysics Data System (ADS)

    Dewey, James B.; Dhar, Sumitrajit

    2015-12-01

    Behavioral pure-tone hearing thresholds and stimulus-frequency otoacoustic emissions (SFOAEs) were measured with a high frequency resolution from 0.5-20 kHz in 15 female participants. Stimuli were calibrated in terms of forward pressure level (FPL). SFOAE responses to 36 dB FPL probes were largest near 1 kHz and declined above 8-10 kHz, though were still measurable at frequencies approaching 16 kHz in some ears. SFOAEs typically dropped in amplitude at a frequency that was roughly one octave below the "corner" frequency of the audiogram, and one-third to one-half of an octave below the frequency where thresholds departed from highly sensitive hearing. High-frequency SFOAE responses are likely limited by a reduction in the efficiency of the underlying generation mechanism and/or a diminished region of generation as the stimulus-driven excitation approaches the basal-most portion of the cochlea.

  17. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    PubMed

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  18. Electric and dielectric behavior of copper-chromium layered double hydroxide intercalated with dodecyl sulfate anions using impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Elhatimi, Wafaa; Bouragba, Fatima Zahra; Lahkale, Redouane; Sadik, Rachid; Lebbar, Nacira; Siniti, Mostapha; Sabbar, Elmouloudi

    2018-05-01

    The Cu2Cr-DS-LDH hybrid was successfully prepared by the anion exchange method at room temperature. The structure, the chemical composition and the physico-chemical properties of the sample were determined using powder X-ray diffraction (PXRD), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA) and inductively coupled plasma (ICP). In this work, the electrical and dielectric properties investigated are determined using impedance spectroscopy (IS) in a frequency range of 1 Hz to 1 MHz. Indeed, the Nyquist diagram modelized by an electrical equivalent circuit showed three contributions attributed respectively to the polarization of grains, grains boundaries and interface electrode-sample. This modelization allowed us to determine the intrinsic electrical parameters of the hybrid (resistance, pseudo-capacitance and relaxation time). The presence of the non-Debye relaxation phenomena was confirmed by the frequency analysis of impedance. Moreover, the evolution of the alternating current conductivity (σac) studied obeys the double power law of Jonscher. The ionic conduction of this material was generated through a jump movement by translation of the charge carriers. As for the dielectric behavior of the material, the evolution of dielectric constant as a function of frequency shows relatively high values in a frequency range between 10 Hz and 1 KHz. The low values of the loss tangent obtained in this frequency zone can valorize this LDH hybrid.

  19. Objective measurement of subjective tinnitus using the acoustic change complex.

    PubMed

    Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong; Lee, Hyo-Jeong

    2017-01-01

    At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1'-P2' complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus.

  20. Objective measurement of subjective tinnitus using the acoustic change complex

    PubMed Central

    Han, Ji-Hye; Won, Joong Yeon; Hong, Sung Kwang; Kim, Ja Hee; Kim, Eun Soo; Kim, Hyung-Jong

    2017-01-01

    At present, there is no objective method for diagnosing subjective sensorineural tinnitus. Recently, the acoustic change complex (ACC) has been used to evaluate neural detection of sounds. Thus, the present study aimed to examine whether the ACC can reflect cortical detection and discrimination of sounds matched with tinnitus frequencies. We hypothesized that the ACC to change stimuli matched with tinnitus frequencies would be decreased in tinnitus patients because the tinnitus interferes with the perception of acoustic changes. To test the hypothesis, 96 ears of normal-hearing (NH) tinnitus patients and controls were tested. Among the tinnitus patients, 33 ears with a tinnitus frequency of 8 kHz constituted the tinnitus group, and the remaining 63 ears with no experience of tinnitus were allocated to the control group. For the 4 kHz non-tinnitus matched frequency, a subset of tinnitus (n = 17) and NH (n = 47) subjects was tested. The acoustic stimuli were pure tones with a total duration of 500 ms consisting of a 1 kHz tone in the first 250 ms and a second tone of either 8 kHz or 4 kHz in the latter 250 ms. The normalized amplitude of the ACC (naACC) was calculated separately for the amplitude of the N1’-P2’ complex evoked by an 8 kHz or 4 kHz change stimulus and for the amplitude of the N1-P2 complex elicited by the initial 1 kHz background stimulus. Our results showed that the naACC to an 8 kHz stimulus in the tinnitus group was significantly smaller than those to 4 kHz and 8 kHz in normal controls. Additionally, in the tinnitus group, the naACC to 4 kHz was greater compared to 8 kHz. The receiver operating characteristic (ROC) curve analysis conducted for naACC to 8 kHz at UCL revealed a fair degree of diagnostic efficacy. Overall, our results indicated that the ACC to a change stimulus matched with the tinnitus frequency can provide an objective measure of frequency-specific tinnitus. PMID:29176873

  1. Surface atrial frequency analysis in patients with atrial fibrillation: a tool for evaluating the effects of intervention.

    PubMed

    Raine, Dan; Langley, Philip; Murray, Alan; Dunuwille, Asunga; Bourke, John P

    2004-09-01

    The aims of this study were to evaluate (1) principal component analysis as a technique for extracting the atrial signal waveform from the standard 12-lead ECG and (2) its ability to distinguish changes in atrial fibrillation (AF) frequency parameters over time and in response to pharmacologic manipulation using drugs with different effects on atrial electrophysiology. Twenty patients with persistent AF were studied. Continuous 12-lead Holter ECGs were recorded for 60 minutes, first, in the drug-free state. Mean and variability of atrial waveform frequency were measured using an automated computer technique. This extracted the atrial signal by principal component analysis and identified the main frequency component using Fourier analysis. Patients were then allotted sequentially to receive 1 of 4 drugs intravenously (amiodarone, flecainide, sotalol, or metoprolol), and changes induced in mean and variability of atrial waveform frequency measured. Mean and variability of atrial waveform frequency did not differ within patients between the two 30-minute sections of the drug-free state. As hypothesized, significant changes in mean and variability of atrial waveform frequency were detected after manipulation with amiodarone (mean: 5.77 vs 4.86 Hz; variability: 0.55 vs 0.31 Hz), flecainide (mean: 5.33 vs 4.72 Hz; variability: 0.71 vs 0.31 Hz), and sotalol (mean: 5.94 vs 4.90 Hz; variability: 0.73 vs 0.40 Hz) but not with metoprolol (mean: 5.41 vs 5.17 Hz; variability: 0.81 vs 0.82 Hz). A technique for continuously analyzing atrial frequency characteristics of AF from the surface ECG has been developed and validated.

  2. New Astrometric Limits on the Stochastic Gravitational Wave Background

    NASA Astrophysics Data System (ADS)

    Darling, Jeremiah K.; Truebenbach, Alexandra; Paine, Jennie

    2018-06-01

    We present new limits on the low frequency (f < 10-8 Hz) stochastic gravitational wave background using correlated extragalactic proper motions. The familiar methods for gravitational wave detection are ground- and space-based laser interferometry, pulsar timing, and polarization of the cosmic microwave background. Astrometry offers an additional path to gravitational wave detection because gravitational waves deflect the light rays of extragalactic objects, creating apparent proper motions in a quadrupolar (and higher order modes) pattern. Astrometry is sensitive to gravitational waves with frequencies between roughly 10-18 Hz and 10-8 Hz (between H0 and 1/3 yr-1), which overlaps and bridges the pulsar timing and CMB polarization regimes. We present the methods and results of two complementary approaches to astrometric gravitational wave detection: (1) a small ~500-object radio interferometric sample with low per-source proper motion uncertainty but large intrinsic proper motions caused by radio jets, and (2) a thousand-fold larger sample with large per-source uncertainties that has small intrinsic proper motions (Gaia active galactic nuclei). Both approaches produce limits on ΩGW, the energy density of gravitational waves as a fraction of the cosmological critical energy density.The authors acknowledge support from the NSF grant AST-1411605 and the NASA grant 14-ATP14-0086.

  3. Measurement of the resistivity of porous materials with an alternating air-flow method.

    PubMed

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  4. Substance P release and neurokinin 1 receptor activation in the rat spinal cord increase with the firing frequency of C-fibers.

    PubMed

    Adelson, D; Lao, L; Zhang, G; Kim, W; Marvizón, J C G

    2009-06-30

    Both the firing frequency of primary afferents and neurokinin 1 receptor (NK1R) internalization in dorsal horn neurons increase with the intensity of noxious stimulus. Accordingly, we studied how the pattern of firing of primary afferent influences NK1R internalization. In rat spinal cord slices, electrical stimulation of the dorsal root evoked NK1R internalization in lamina I neurons by inducing substance P release from primary afferents. The stimulation frequency had pronounced effects on NK1R internalization, which increased up to 100 Hz and then diminished abruptly at 200 Hz. Peptidase inhibitors increased NK1R internalization at frequencies below 30 Hz, indicating that peptidases limit the access of substance P to the receptor at moderate firing rates. NK1R internalization increased with number of pulses at all frequencies, but maximal internalization was substantially lower at 1-10 Hz than at 30 Hz. Pulses organized into bursts produced the same NK1R internalization as sustained 30 Hz stimulation. To determine whether substance P release induced at high stimulation frequencies was from C-fibers, we recorded compound action potentials in the sciatic nerve of anesthetized rats. We observed substantial NK1R internalization when stimulating at intensities evoking a C-elevation, but not at intensities evoking only an Adelta-elevation. Each pulse in trains at frequencies up to 100 Hz evoked a C-elevation, demonstrating that C-fibers can follow these high frequencies. C-elevation amplitudes declined progressively with increasing stimulation frequency, which was likely caused by a combination of factors including temporal dispersion. In conclusion, the instantaneous firing frequency in C-fibers determines the amount of substance P released by noxious stimuli.

  5. Substance P release and neurokinin 1 receptor activation in the rat spinal cord increases with the firing frequency of C-fibers

    PubMed Central

    Adelson, David; Lao, Lijun; Zhang, Guohua; Kim, Woojae; Marvizón, Juan Carlos G.

    2009-01-01

    Both the firing frequency of primary afferents and neurokinin 1 receptor (NK1R) internalization in dorsal horn neurons increase with the intensity of noxious stimulus. Accordingly, we studied how the pattern of firing of primary afferent influences NK1R internalization. In rat spinal cord slices, electrical stimulation of the dorsal root evoked NK1R internalization in lamina I neurons by inducing substance P release from primary afferents. The stimulation frequency had pronounced effects on NK1R internalization, which increased up to 100 Hz and then diminished abruptly at 200 Hz. Peptidase inhibitors increased NK1R internalization at frequencies below 30 Hz, indicating that peptidases limit the access of substance P to the receptor at moderate firing rates. NK1R internalization increased with number of pulses at all frequencies, but maximal internalization was substantially lower at 1–10 Hz than at 30 Hz. Pulses organized into bursts produced the same NK1R internalization as sustained 30 Hz stimulation. To determine whether substance P release induced at high stimulation frequencies was from C-fibers, we recorded compound action potentials in the sciatic nerve of anesthetized rats. We observed substantial NK1R internalization when stimulating at intensities evoking a C-elevation, but not at intensities evoking only an Aδ-elevation. Each pulse in trains at frequencies up to 100 Hz evoked a C-elevation, demonstrating that C-fibers can follow these high frequencies. C-elevation amplitudes declined progressively with increasing stimulation frequency, which was likely caused by a combination of factors including temporal dispersion. In conclusion, the instantaneous firing frequency in C-fibers determines the amount of substance P released by noxious stimuli. PMID:19336248

  6. Perception of dissonance by people with normal hearing and sensorineural hearing loss

    NASA Astrophysics Data System (ADS)

    Tufts, Jennifer B.; Molis, Michelle R.; Leek, Marjorie R.

    2005-08-01

    The purpose of this study was to determine whether the perceived sensory dissonance of pairs of pure tones (PT dyads) or pairs of harmonic complex tones (HC dyads) is altered due to sensorineural hearing loss. Four normal-hearing (NH) and four hearing-impaired (HI) listeners judged the sensory dissonance of PT dyads geometrically centered at 500 and 2000 Hz, and of HC dyads with fundamental frequencies geometrically centered at 500 Hz. The frequency separation of the members of the dyads varied from 0 Hz to just over an octave. In addition, frequency selectivity was assessed at 500 and 2000 Hz for each listener. Maximum dissonance was perceived at frequency separations smaller than the auditory filter bandwidth for both groups of listners, but maximum dissonance for HI listeners occurred at a greater proportion of their bandwidths at 500 Hz than at 2000 Hz. Further, their auditory filter bandwidths at 500 Hz were significantly wider than those of the NH listeners. For both the PT and HC dyads, curves displaying dissonance as a function of frequency separation were more compressed for the HI listeners, possibly reflecting less contrast between their perceptions of consonance and dissonance compared with the NH listeners.

  7. Development Towards a Space Qualified Laser Stabilization System in Support of Space-Based Optical Interferometers

    NASA Technical Reports Server (NTRS)

    Seidel, David J.; Dubovitsky, Serge

    2000-01-01

    We report on the development, functional performance and space-qualification status of a laser stabilization system supporting a space-based metrology source used to measure changes in optical path lengths in space-based stellar interferometers. The Space Interferometry Mission (SIM) and Deep Space 3 (DS-3) are two missions currently funded by the National Aeronautics and Space Administration (NASA) that are space-based optical interferometers. In order to properly recombine the starlight received at each telescope of the interferometer it is necessary to perform high resolution laser metrology to stabilize the interferometer. A potentially significant error source in performing high resolution metrology length measurements is the potential for fluctuations in the laser gauge itself. If the laser frequency or wavelength is changing over time it will be misinterpreted as a length change in one of the legs of the interferometer. An analysis of the frequency stability requirement for SIM resulted in a fractional frequency stability requirement of square root (S(sub y)(f)) = <2 x 10(exp -12)/square root(Hz) at Fourier frequencies between 10 Hz and 1000 Hz. The DS-3 mission stability requirement is further increased to square root (S(sub y)(f)) = <5 x 10(exp -14)/Square root(Hz) at Fourier frequencies between 0.2 Hz and 10 kHz with a goal of extending the low frequency range to 0.05 Hz. The free running performance of the Lightwave Electronics NPRO lasers, which are the baseline laser for both SIM and DS-3 vary in stability and we have measured them to perform as follows (9 x l0(exp -11)/ f(Hz))(Hz)/square root(Hz)) = <( square root (S(sub y)(f)) = <(1.3 x l0(exp -8)/ f(Hz))/Square root(Hz). In order to improve the frequency stability of the laser we stabilize the laser to a high finesse optical cavity by locking the optical frequency of the laser to one of the transmission modes of the cavity. At JPL we have built a prototype space-qualifiable system meeting the stability requirements of SIM, which has been delivered to one of the SIM testbeds. We have also started on the development of a system to meet the stability needs of DS-3.

  8. Effect of substrate bending on the piezoelectric measurement of PZT thin film

    NASA Astrophysics Data System (ADS)

    Xu, Xiaohui; Tang, Jianhong; He, Liangna

    2009-05-01

    Bonding conditions between PZT thin film and sample holder greatly affect the strain measurement of the PZT sample. The influence of various bonding conditions on the measured displacement were analyzed using finite element analysis (FEA). One-end fixed sample induces the maximum bending displacement. Experiments were performed on sol-gel derived PZT thin film. The voltage-displacement curve and "butterfly" loop were measured using laser Doppler method with phase detection. Experimental results agreed well with the simulated ones. The measured frequency dependence of piezoelectric response of PZT thin film indicated that, if the operating frequency was lower than 2 kHz, good bonding effect could be obtained when the entire back surface of the sample was glued to a rigid supporter using epoxy resin. A simple bonding model which considered the adhesives as a spring was used to estimate the frequency response of PZT thin film sample.

  9. High-frequency combination coding-based steady-state visual evoked potential for brain computer interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Feng; Zhang, Xin; Xie, Jun

    2015-03-10

    This study presents a new steady-state visual evoked potential (SSVEP) paradigm for brain computer interface (BCI) systems. The goal of this study is to increase the number of targets using fewer stimulation high frequencies, with diminishing subject’s fatigue and reducing the risk of photosensitive epileptic seizures. The new paradigm is High-Frequency Combination Coding-Based High-Frequency Steady-State Visual Evoked Potential (HFCC-SSVEP).Firstly, we studied SSVEP high frequency(beyond 25 Hz)response of SSVEP, whose paradigm is presented on the LED. The SNR (Signal to Noise Ratio) of high frequency(beyond 40 Hz) response is very low, which is been unable to be distinguished through the traditional analysis method;more » Secondly we investigated the HFCC-SSVEP response (beyond 25 Hz) for 3 frequencies (25Hz, 33.33Hz, and 40Hz), HFCC-SSVEP produces n{sup n} with n high stimulation frequencies through Frequence Combination Code. Further, Animproved Hilbert-huang transform (IHHT)-based variable frequency EEG feature extraction method and a local spectrum extreme target identification algorithmare adopted to extract time-frequency feature of the proposed HFCC-SSVEP response.Linear predictions and fixed sifting (iterating) 10 time is used to overcome the shortage of end effect and stopping criterion,generalized zero-crossing (GZC) is used to compute the instantaneous frequency of the proposed SSVEP respondent signals, the improved HHT-based feature extraction method for the proposed SSVEP paradigm in this study increases recognition efficiency, so as to improve ITR and to increase the stability of the BCI system. what is more, SSVEPs evoked by high-frequency stimuli (beyond 25Hz) minimally diminish subject’s fatigue and prevent safety hazards linked to photo-induced epileptic seizures, So as to ensure the system efficiency and undamaging.This study tests three subjects in order to verify the feasibility of the proposed method.« less

  10. [Echolocation calls of free-flying Himalayan swiftlets (Aerodramus brevirostris)].

    PubMed

    Wang, Bin; Ma, Jian-Zhang; Chen, Yi; Tan, Liang-Jing; Liu, Qi; Shen, Qi-Qi; Liao, Qing-Yi; Zhang, Li-Biao

    2013-02-01

    Here, we present our findings of free-flying echolocation calls of Himalayan swiftlets (Aerodramus brevirostris), which were recorded in Shenjing Cave, Hupingshan National Reserve, Shimen County, Hunan Province in June 2012, using Avisoft-UltraSoundGate 116(e). We noted that after foraging at dusk, the Himalayan swiftlets flew fast into the cave without clicks, and then slowed down in dark area in the cave, but with sounds. The echolocation sounds of Himalayan swiftlets are broadband, double noise burst clicks, separated by a short pause. The inter-pulse intervals between double clicks (99.3±3.86 ms)were longer than those within double clicks (6.6±0.42 ms) (P<0.01). With the exception of peak frequency, between 6.2±0.08 kHz and 6.2±0.10 kHz, (P>0.05) and pulse duration 2.9±0.12 ms, 3.2±0.17 ms, (P>0.05) between the first and second, other factors-maximum frequency, minimum frequency, frequency bandwidth, and power-were significantly different between the clicks. The maximum frequency of the first pulse (20.1±1.10 kHz) was higher than that of second (15.4±0.98 kHz) (P<0.01), while the minimum frequency of the first pulse (3.7±0.12 kHz) was lower than that of second (4.0±0.09 kHz) (P<0.05); resulting in the frequency bandwidth of the first pulse (16.5±1.17 kHz) longer than that of second (11.4±1.01 kHz) (P<0.01). The power of the first pulse (-32.5±0.60 dB) was higher than that of second (-35.2±0.94 dB) (P<0.05). More importantly, we found that Himalayan swiftlets emitted echolocation pulses including ultrasonic sound, with a maximum frequency reaching 33.2 kHz.

  11. Electrocardiogram frequency change by extracorporeal blood perfusion in a swine ventricular fibrillation model

    PubMed Central

    2013-01-01

    Background Extracorporeal cardiopulmonary resuscitation (ECPR) refers to the application of extracorporeal blood circulation with oxygenation as a resuscitation tool. The objective of this study is to observe the frequency component changes in the electrocardiogram (ECG) by ECPR during prolonged ventricular fibrillation (VF). Methods Six swine were prepared as a VF model. Extracorporeal blood circulation with a pulsatile blood pump and oxygenator was set up for the model. ECG signals were measured for 13 min during VF and analyzed using frequency analysis methods. The median frequency (MF), dominant frequency (DF), and amplitude spectrum area (AMSA) were calculated from a spectrogram obtained using short-time Fourier transform (STFT). Results MF decreased from 11 Hz at the start to 9 Hz at 2 min after VF and then increased to 11 Hz at 4.5 min after VF. DF started at 7 Hz and increased to 11 Hz within the first min and decreased to 9 Hz at 2 min, then increased to 12 Hz at 4.5 min after VF. Both frequency components decreased gradually from 4.5 min until 10 min after VF. After the oxygenated blood perfusion was initiated, both MF and DF increased remarkably and exceeded 12 and 14 Hz, respectively. Similarly, AMSA decreased gradually for the first 10 min, but increased remarkably and varied beyond 13 mV∙Hz after the oxygenated blood supply started. Remarkable frequency increases in ECG due to the oxygenated blood perfusion during ECPR were observed in the swine VF model. Conclusions The ECG frequency analysis during ECPR can give the resuscitation provider important information about the cardiac perfusion status and the appropriateness of the ECPR setup as well as the prediction of defibrillation success. PMID:24274395

  12. Frequency stabilization for space-based missions using optical fiber interferometry.

    PubMed

    McRae, Terry G; Ngo, Silvie; Shaddock, Daniel A; Hsu, Magnus T L; Gray, Malcolm B

    2013-02-01

    We present measurement results for a laser frequency reference, implemented with an all-optical fiber Michelson interferometer, down to frequencies as low as 1 mHz. Optical fiber is attractive for space-based operations as it is physically robust, small and lightweight. The small free spectral range of fiber interferometers also provides the possibility to prestabilize two lasers on two distant spacecraft and ensures that the beatnote remains within the detector bandwidth. We demonstrate that these fiber interferometers are viable candidates for future laser-based gravity recovery and climate experiment missions requiring a stability of 30 Hz/√Hz over a 10 mHz-1 Hz bandwidth.

  13. Measurement of high-degree solar oscillation frequencies

    NASA Technical Reports Server (NTRS)

    Bachmann, K. T.; Duvall, T. L., Jr.; Harvey, J. W.; Hill, F.

    1995-01-01

    We present m-averaged solar p- and f-mode oscillation frequencies over the frequency range nu greater than 1.8 and less than 5.0 mHz and the spherical harmonic degree range l greater than or equal to 100 and less than or equal to 1200 from full-disk, 1000 x 1024 pixel, Ca II intensity images collected 1993 June 22-25 with a temporal cadence of 60 s. We itemize the sources and magnitudes of statistical and systematic uncertainties and of small frequency corrections, and we show that our frequencies represent an improvement in accuracy and coverage over previous measurements. Our frequencies agree at the 2 micro Hz level with Mount Wilson frequencies determined for l less than or equal to 600 from full-disk images, and we find systematic offsets of 10-20 micro Hz with respect to frequencies measured from Big Bear and La Palma observations. We give evidence that these latter offsets are indicative of spatial scaling uncertainties associated with the analysis of partial-disk images. In comparison with theory, our p-mode frequencies agree within 10 micro Hz of frequencies predicted by the Los Alamos model but are as much as 100 micro Hz smaller than frequencies predicted by the Denmark and Yale models at degrees near 1000. We also find systematic differences between our n = 0 frequencies and the frequencies closely agreed upon by all three models.

  14. Dielectric Properties of PMMA and its Composites with ZrO2

    NASA Astrophysics Data System (ADS)

    Sannakki, Basavaraja; Anita

    The polymer films of PMMA with different thickness and its composites with ZrO2 at various weight percentages but of same thickness have been studied. The determination of its dielectric properties, dielectric loss, a.conductivity and dielectric modulus were carried out using capacitance measurements of the above samples as a function of frequency, over the range 50 Hz - 5 MHz at room temperature. The films of PMMA and its composites have been characterized using X-Ray Diffractometer. The dielectric permittivity of films of PMMA behaves nonlinearly as frequency increases over the range 50-300 Hz, where as above 300 Hz the values of dielectric constant remains constant. But it is observed that the dielectric constant of PMMA increases as thickness of the film increases. In case of composite films of PMMA with ZrO2 the values of dielectric permittivity decreases gradually up to frequency of around 1 KHz and at higher frequencies it remains constant for all the weight percentages of ZrO2. The complex form of dielectric modulus of PMMA is obtained from the experimentally measured data of dielectric constant and dielectric loss values. The relaxation time of the orientation of dipoles is obtained from the peak value of angular frequency through the plots of imaginary part of electrical modulus as function of frequency. The impedance of PMMA polymer increases as thickness of the films increases. The a c conductivity of PMMA film remains constant up to frequency of 1 MHz and above. It shows a nonlinear phenomenon with peak values at frequency 4 MHz. Shape and size of the nanoparticles of composite film of PMMA with ZrO2 was analyzed by Field Emission Scanning Electron Microscope (FESEM).

  15. EFFECTS OF ELF (EXTREMELY LOW FREQUENCY) (1-120 HZ) AND MODULATED (50 HZ) RF (RADIO FREQUENCY) FIELDS ON THE EFFLUX OF CALCIUM IONS FROM BRAIN TISSUE IN VITRO

    EPA Science Inventory

    The authors have previously shown that 16-Hz, sinusoidal electromagnetic fields can cause enhanced efflux of calcium ions from chick brain tissue, in vitro, in two intensity regions centered on 6 and 40 Vp-p/m. Alternatively, 1-Hz and 30-Hz fields at 40Vp-p/m did not cause enhanc...

  16. Magic angle spinning NMR with metallized rotors as cylindrical microwave resonators.

    PubMed

    Scott, Faith J; Sesti, Erika L; Choi, Eric J; Laut, Alexander J; Sirigiri, Jagadishwar R; Barnes, Alexander B

    2018-04-19

    We introduce a novel design for millimeter wave electromagnetic structures within magic angle spinning (MAS) rotors. In this demonstration, a copper coating is vacuum deposited onto the outside surface of a sapphire rotor at a thickness of 50 nm. This thickness is sufficient to reflect 197-GHz microwaves, yet not too thick as to interfere with radiofrequency fields at 300 MHz or prevent sample spinning due to eddy currents. Electromagnetic simulations of an idealized rotor geometry show a microwave quality factor of 148. MAS experiments with sample rotation frequencies of ω r /2π = 5.4 kHz demonstrate that the drag force due to eddy currents within the copper does not prevent sample spinning. Spectra of sodium acetate show resolved 13 C J-couplings of 60 Hz and no appreciable broadening between coated and uncoated sapphire rotors, demonstrating that the copper coating does not prevent shimming and high-resolution nuclear magnetic resonance spectroscopy. Additionally, 13 C Rabi nutation curves of ω 1 /2π = 103 kHz for both coated and uncoated rotors indicate no detrimental impact of the copper coating on radio frequency coupling of the nuclear spins to the sample coil. We present this metal coated rotor as a first step towards an MAS resonator. MAS resonators are expected to have a significant impact on developments in electron decoupling, pulsed dynamic nuclear polarization (DNP), room temperature DNP, DNP with low-power microwave sources, and electron paramagnetic resonance detection. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Characterization of the MEMS Directional Sound Sensor in the High Frequency (15-20 kHz) Range

    DTIC Science & Technology

    2011-12-01

    frequency response that is almost flat from 50 Hz to 20 kHz [9]. The sound source is a Selenium loudspeaker type DH200E attached to the internal...University Science Books, 2005. [12] W. Zhang and K. Turner, “Frequency dependent fluid damping of micro/ nano flexural resonators: Experiment, model and

  18. 47 CFR 90.214 - Transient frequency behavior.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...

  19. 47 CFR 90.214 - Transient frequency behavior.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...

  20. 47 CFR 90.214 - Transient frequency behavior.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...

  1. 47 CFR 90.214 - Transient frequency behavior.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Transient frequency behavior. 90.214 Section 90... PRIVATE LAND MOBILE RADIO SERVICES General Technical Standards § 90.214 Transient frequency behavior... Behavior for Equipment Designed to Operate on 25 kHz Channels t1 4 ±25.0 kHz 5.0 ms 10.0 ms t2 ±12.5 kHz 20...

  2. Polarization of low-frequency electromagnetic radiation in the lobes of Jupiter's magnetotail

    NASA Technical Reports Server (NTRS)

    Moses, S. L.; Kennel, C. F.; Coroniti, F. V.; Scarf, F. L.; Kurth, W. S.

    1987-01-01

    The plasma wave instruments on the Voyager spacecraft have detected intense electromagnetic radiation within the lobes of Jupiter's magnetic tail down to the lowest frequency of the detector (10 Hz). During a yaw maneuver performed by Voyager 1 in the lobe of the Jovian magnetotail, a modulation appeared in the amplitudes of waves detected in the 10-, 17.8- and 31.1-Hz channels of the plasma wave analyzer, well below the local electron cyclotron frequency of 260 Hz. The lowest amplitudes occurred when the antenna axis was most nearly parallel to the magnetic field. Wave amplitudes in the 56.2-Hz and higher frequency channels remained nearly constant during the maneuver. From the cold-plasma theory of electromagnetic waves, it is concluded that the plasma frequency was between the 56.2- and 31.1-Hz channels where the parallel-polarized component of the spectrum cuts off. This implies a tail-lobe density between 0.000032 and 0.000015/cu cm. The left-hand cutoff frequency would then be below 10 Hz, consistent with either the Z-mode (L, X) or whistlers (R-mode) in the modulated channels.

  3. The frequency range of TMJ sounds.

    PubMed

    Widmalm, S E; Williams, W J; Djurdjanovic, D; McKay, D C

    2003-04-01

    There are conflicting opinions about the frequency range of temporomandibular joint (TMJ) sounds. Some authors claim that the upper limit is about 650 Hz. The aim was to test the hypothesis that TMJ sounds may contain frequencies well above 650 Hz but that significant amounts of their energy are lost if the vibrations are recorded using contact sensors and/or travel far through the head tissues. Time-frequency distributions of 172 TMJ clickings (three subjects) were compared between recordings with one microphone in the ear canal and a skin contact transducer above the clicking joint and between recordings from two microphones, one in each ear canal. The energy peaks of the clickings recorded with a microphone in the ear canal on the clicking side were often well above 650 Hz and always in a significantly higher area (range 117-1922 Hz, P < 0.05 or lower) than in recordings obtained with contact sensors (range 47-375 Hz) or in microphone recordings from the opposite ear canal (range 141-703 Hz). Future studies are required to establish normative frequency range values of TMJ sounds but need methods also capable of recording the high frequency vibrations.

  4. Interpretations of Frequency Domain Analyses of Neural Entrainment: Periodicity, Fundamental Frequency, and Harmonics.

    PubMed

    Zhou, Hong; Melloni, Lucia; Poeppel, David; Ding, Nai

    2016-01-01

    Brain activity can follow the rhythms of dynamic sensory stimuli, such as speech and music, a phenomenon called neural entrainment. It has been hypothesized that low-frequency neural entrainment in the neural delta and theta bands provides a potential mechanism to represent and integrate temporal information. Low-frequency neural entrainment is often studied using periodically changing stimuli and is analyzed in the frequency domain using the Fourier analysis. The Fourier analysis decomposes a periodic signal into harmonically related sinusoids. However, it is not intuitive how these harmonically related components are related to the response waveform. Here, we explain the interpretation of response harmonics, with a special focus on very low-frequency neural entrainment near 1 Hz. It is illustrated why neural responses repeating at f Hz do not necessarily generate any neural response at f Hz in the Fourier spectrum. A strong neural response at f Hz indicates that the time scales of the neural response waveform within each cycle match the time scales of the stimulus rhythm. Therefore, neural entrainment at very low frequency implies not only that the neural response repeats at f Hz but also that each period of the neural response is a slow wave matching the time scale of a f Hz sinusoid.

  5. A Comparison Study of Normal-Incidence Acoustic Impedance Measurements of a Perforate Liner

    NASA Technical Reports Server (NTRS)

    Schultz, Todd; Liu, Fei; Cattafesta, Louis; Sheplak, Mark; Jones, Michael

    2009-01-01

    The eduction of the acoustic impedance for liner configurations is fundamental to the reduction of noise from modern jet engines. Ultimately, this property must be measured accurately for use in analytical and numerical propagation models of aircraft engine noise. Thus any standardized measurement techniques must be validated by providing reliable and consistent results for different facilities and sample sizes. This paper compares normal-incidence acoustic impedance measurements using the two-microphone method of ten nominally identical individual liner samples from two facilities, namely 50.8 mm and 25.4 mm square waveguides at NASA Langley Research Center and the University of Florida, respectively. The liner chosen for this investigation is a simple single-degree-of-freedom perforate liner with resonance and anti-resonance frequencies near 1.1 kHz and 2.2 kHz, respectively. The results show that the ten measurements have the most variation around the anti-resonance frequency, where statistically significant differences exist between the averaged results from the two facilities. However, the sample-to-sample variation is comparable in magnitude to the predicted cross-sectional area-dependent cavity dissipation differences between facilities, providing evidence that the size of the present samples does not significantly influence the results away from anti-resonance.

  6. 47 CFR 87.187 - Frequencies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...

  7. 47 CFR 87.187 - Frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...

  8. 47 CFR 87.187 - Frequencies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...

  9. 47 CFR 87.187 - Frequencies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...

  10. 47 CFR 87.187 - Frequencies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Aircraft Stations § 87.187 Frequencies. (a) Frequencies used for air-ground Communications are listed in... over the high seas. (d) 500 kHz an international calling and distress frequency for aircraft on flights... air-ground communications. (g) The frequency 4125 kHz may be used for distress and safety...

  11. Investigations on Cu2+-substituted Ni-Zn ferrite nanoparticles

    NASA Astrophysics Data System (ADS)

    Amarjeet; Kumar, Vinod

    2016-11-01

    CuxNi(1-x)/2Zn(1-x)/2Fe2O4 (x = 0.1, 0.3 and 0.5) nanoparticles were prepared by chemical co-precipitation method. The developed nanoparticles were characterized for structural properties by powder X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. Peak position in the X-ray diffraction pattern confirmed the single spinel phase of the developed particles. Infrared (IR) spectroscopy in mid-IR range showed the presence of characteristic absorption bands corresponding to octahedral and tetrahedral bonds in the spinel structure of prepared samples. Thermo-gravimetric analysis (TGA) measurements showed a considerable weight loss in the developed samples above 700∘C. Frequency dependence of the electrical properties of the developed material pellets was studied in the frequency range of 1 kHz-5 MHz. Temperature dependence of the dielectric constant of Cu0.1Ni0.45Zn0.45Fe2O4 was studied at different temperatures, i.e. at 425, 450 and 475 K, in the frequency range of 1 kHz-5 MHz. It was found that the electrical conductivity decreases with increasing Cu2+ ion content while it increases with the increase in temperature.

  12. Dominant side in single-leg stance stability during floor oscillations at various frequencies

    PubMed Central

    2014-01-01

    Background We investigated lateral dominance in the postural stability of single-leg stance with anteroposterior floor oscillations at various frequencies. Methods Thirty adults maintained a single-leg stance on a force platform for 20 seconds per trial. Trials were performed with no oscillation (static condition) and with anteroposterior floor oscillations (2.5-cm amplitude) at six frequencies: 0.25, 0.5, 0.75, 1.0, 1.25 and 1.5 Hz (dynamic condition). A set of three trials was performed on each leg in each oscillation frequency in random order. The mean speed of the center of pressure in the anteroposterior direction (CoPap) was calculated as an index of postural stability, and frequency analysis of CoPap sway was performed. Footedness for carrying out mobilizing activities was assessed with a questionnaire. Results CoPap speed exponentially increased as oscillation frequency increased in both legs. The frequency analysis of CoPap showed a peak <0.3 Hz at no oscillation. The frequency components at 0.25-Hz oscillation included common components with no oscillation and those at 1.5-Hz oscillation showed the maximum amplitude among all conditions. Postural stability showed no significant difference between left- and right-leg stance at no oscillation and oscillations ≤1.25 Hz, but at 1.5-Hz oscillation was significantly higher in the right-leg stance than in the left-leg stance. For the lateral dominance of postural stability at individual levels, the lateral difference in postural stability at no oscillation was positively correlated with that at 0.25-Hz oscillation (r = 0.51) and negatively correlated with that at 1.5-Hz oscillation (r = -0.53). For 70% of subjects, the dominant side of postural stability was different at no oscillation and 1.5-Hz oscillation. In the subjects with left- or right-side dominance at no oscillation, 94% or 38% changed their dominant side at 1.5-Hz oscillation, with a significant difference between these percentages. In the 1.5-Hz oscillation, 73% of subjects had concordance between the dominant side of postural stability and that of mobilizing footedness. Conclusion In static conditions, there was no lateral dominance of stability during single-leg stance. At 1.5-Hz oscillation, the highest frequency, right-side dominance of postural stability was recognized. Functional role in supporting leg may be divided between left and right legs according to the change of balance condition from static to dynamic. PMID:25127541

  13. Amplitude modulation detection with concurrent frequency modulation.

    PubMed

    Nagaraj, Naveen K

    2016-09-01

    Human speech consists of concomitant temporal modulations in amplitude and frequency that are crucial for speech perception. In this study, amplitude modulation (AM) detection thresholds were measured for 550 and 5000 Hz carriers with and without concurrent frequency modulation (FM), at AM rates crucial for speech perception. Results indicate that adding 40 Hz FM interferes with AM detection, more so for 5000 Hz carrier and for frequency deviations exceeding the critical bandwidth of the carrier frequency. These findings suggest that future cochlear implant processors, encoding speech fine-structures may consider limiting the FM to narrow bandwidth and to low frequencies.

  14. The K2 Galactic Archaeology Program Data Release. I. Asteroseismic Results from Campaign 1

    NASA Astrophysics Data System (ADS)

    Stello, Dennis; Zinn, Joel; Elsworth, Yvonne; Garcia, Rafael A.; Kallinger, Thomas; Mathur, Savita; Mosser, Benoit; Sharma, Sanjib; Chaplin, William J.; Davies, Guy; Huber, Daniel; Jones, Caitlin D.; Miglio, Andrea; Silva Aguirre, Victor

    2017-01-01

    NASA's K2 mission is observing tens of thousands of stars along the ecliptic, providing data suitable for large-scale asteroseismic analyses to inform galactic archaeology studies. Its first campaign covered a field near the north Galactic cap, a region never covered before by large asteroseismic-ensemble investigations, and was therefore of particular interest for exploring this part of our Galaxy. Here we report the asteroseismic analysis of all stars selected by the K2 Galactic Archaeology Program during the mission's “north Galactic cap” campaign 1. Our consolidated analysis uses six independent methods to measure the global seismic properties, in particular the large frequency separation and the frequency of maximum power. From the full target sample of 8630 stars we find about 1200 oscillating red giants, a number comparable with estimates from galactic synthesis modeling. Thus, as a valuable by-product we find roughly 7500 stars to be dwarfs, which provide a sample well suited for galactic exoplanet occurrence studies because they originate from our simple and easily reproducible selection function. In addition, to facilitate the full potential of the data set for galactic archaeology, we assess the detection completeness of our sample of oscillating red giants. We find that the sample is at least nearly complete for stars with 40 ≲ {ν }\\max /μHz ≲ 270 and {ν }\\max ,{detect}< 2.6× {10}6\\cdot {2}-{\\text{Kp}} μHz. There is a detection bias against helium core burning stars with {ν }\\max ˜ 30 μHz, affecting the number of measurements of {{Δ }}ν and possibly also {ν }\\max . Although we can detect oscillations down to {\\text{Kp}} = 15, our campaign 1 sample lacks enough faint giants to assess the detection completeness for stars fainter than {\\text{Kp}} ˜ 14.5.

  15. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates

    PubMed Central

    Bleeck, Stefan; McAlpine, David

    2015-01-01

    Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926

  16. Potentials evoked by chirp-modulated tones: a new technique to evaluate oscillatory activity in the auditory pathway.

    PubMed

    Artieda, J; Valencia, M; Alegre, M; Olaziregi, O; Urrestarazu, E; Iriarte, J

    2004-03-01

    Steady-state potentials are oscillatory responses generated by a rhythmic stimulation of a sensory pathway. The frequency of the response, which follows the frequency of stimulation, is maximal at a stimulus rate of 40 Hz for auditory stimuli. The exact cause of these maximal responses is not known, although some authors have suggested that they might be related to the 'working frequency' of the auditory cortex. Testing of the responses to different frequencies of stimulation may be lengthy if a single frequency is studied at a time. Our aim was to develop a fast technique to explore the oscillatory response to auditory stimuli, using a tone modulated in amplitude by a sinusoid whose frequency increases linearly in frequency ('chirp') from 1 to 120 Hz. Time-frequency transforms were used for the analysis of the evoked responses in 10 subjects. Also, we analyzed whether the peaks in these responses were due to increases of amplitude or to phase-locking phenomena, using single-sweep time-frequency transforms and inter-trial phase analysis. The pattern observed in the time-frequency transform of the chirp-evoked potential was very similar in all subjects: a diagonal band of energy was observed, corresponding to the frequency of modulation at each time instant. Two components were present in the band, one around 45 Hz (30-60 Hz) and a smaller one between 80 and 120 Hz. Inter-trial phase analysis showed that these components were mainly due to phase locking phenomena. A simultaneous testing of the amplitude-modulation-following oscillatory responses to auditory stimulation is feasible using a tone modulated in amplitude at increasing frequencies. The maximal energies found at stimulation frequencies around 40 Hz are probably due to increased phase-locking of the individual responses.

  17. Identification of Natural Frequency of Low Rise Building on Soft Ground Profile using Ambient Vibration Method

    NASA Astrophysics Data System (ADS)

    Kamarudin, A. F.; Zainal Abidin, M. H.; Mokhatar, S. N.; Daud, M. E.; Ibrahim, A.; Ibrahim, Z.; Noh, M. S. Md

    2018-04-01

    Natural frequency is the rate at which a body to vibrate or oscillate. Application of ambient vibration (AV) excitation is widely used nowadays as the input motion for building predominant frequency, fo, and ground fundamental frequency, Fo, prediction due to simple, fast, non-destructive, simple handling operation and reliable result. However, it must be emphasized and caution to isolate these frequencies (fo and Fo) from spurious frequencies of site-structure effects especially to low rise building on soft ground deposit. In this study, identification of fo and Fo by using AV measurements were performed on ground and 4-storey primary school reinforced concrete (RC) building at Sekolah Kebangsaan (SK) Sg. Tongkang, Rengit, Johor using 1 Hz of tri-axial seismometer sensor. Overlapping spectra between Fourier Amplitude Spectra (FAS) from and Horizontal to Vertical Spectra Ratio (HVSR) were used to distinguish respective frequencies of building and ground natural frequencies. Three dominant frequencies were identified from the FAS curves at 1.91 Hz, 1.98 Hz and 2.79 Hz in longitudinal (East West-EW), transverse (North South-NS) and vertical (UD) directions. It is expected the building has deformed in translational mode based on the first peak frequency by respective NS and EW components of FAS spectrum. Vertical frequency identified from the horizontal spectrums, might induces to the potential of rocking effect experienced by the school building. Meanwhile, single peak HVSR spectrum at low ground fundamental frequency concentrated at 0.93 Hz indicates to the existence deep contrast of soft deposit. Strong interaction between ground and building at similar frequency (0.93 Hz) observed from the FAS curves on the highest floor has shown the building to behave as a dependent unit against ground response as one rigid mass.

  18. A reconfigurable multi-mode multi-band transmitter with integrated frequency synthesizer for short-range wireless communication

    NASA Astrophysics Data System (ADS)

    Nan, Qi; Fan, Chen; Lingwei, Zhang; Xiaoman, Wang; Baoyong, Chi

    2013-09-01

    A reconfigurable multi-mode direct-conversion transmitter (TX) with integrated frequency synthesizer (FS) is presented. The TX as well as the FS is designed with a flexible architecture and frequency plan, which helps to support all the 433/868/915 MHz ISM band signals, with the reconfigurable bandwidth from 250 kHz to 2 MHz. In order to save power and chip area, only one 1.8 GHz VCO is adopted to cover the whole frequency range. All the operation modes can be regulated in real time by configuring the integrated register-bank through an SPI interface. Implemented in 180 nm CMOS, the FS achieves a frequency coverage of 320-460 MHz and 620-920 MHz. The lowest phase noise can be -107 dBc/Hz at a 100 kHz offset and -126 dBc/Hz at a 1 MHz offset. The transmitter features a + 10.2 dBm peak output power with a +9.5 dBm 1-dB-compression point and 250 kHz/500 kHz/1 MHz/2 MHz reconfigurable signal bandwidth.

  19. Radial evolution of power spectra of interplanetary Alfvenic turbulence

    NASA Technical Reports Server (NTRS)

    Bavassano, B.; Dobrowolny, M.; Mariani, F.; Ness, N. F.

    1981-01-01

    The radial evolution of the power spectra of the MHD turbulence within the trailing edge of high speed streams in the solar wind was investigated with the magnetic field data of Helios 1 and 2 for heliocentric distance between 0.3 and 0.9 AU. In the analyzed frequency range (.00028 Hz to .0083 Hz) the computed spectra have, near the Earth, values of the spectral index close to that predicted for an incompressible hydromagnetic turbulence in a stationary state. Approaching the Sun the spectral slope remains unchanged for frequencies f or approximately .00 Hz, whereas at lower frequencies, a clear evolution toward a less steep fall off with frequency is found. The radial gradient of the power in Alfvenic fluctuations depends on frequency and it increases upon increasing frequency. For frequencies f or approximately .00 Hz, however, the radial gradient remains approximately the same. Possible theoretical implications of the observational features are discussed.

  20. The 10 Hz Frequency: A Fulcrum For Transitional Brain States.

    PubMed

    Garcia-Rill, E; D'Onofrio, S; Luster, B; Mahaffey, S; Urbano, F J; Phillips, C

    A 10 Hz rhythm is present in the occipital cortex when the eyes are closed (alpha waves), in the precentral cortex at rest ( mu rhythm), in the superior and middle temporal lobe ( tau rhythm), in the inferior olive (projection to cerebellar cortex), and in physiological tremor (underlying all voluntary movement). These are all considered resting rhythms in the waking brain which are "replaced" by higher frequency activity with sensorimotor stimulation. That is, the 10 Hz frequency fulcrum is replaced on the one hand by lower frequencies during sleep, or on the other hand by higher frequencies during volition and cognition. The 10 Hz frequency fulcrum is proposed as the natural frequency of the brain during quiet waking, but is replaced by higher frequencies capable of permitting more complex functions, or by lower frequencies during sleep and inactivity. At the center of the transition shifts to and from the resting rhythm is the reticular activating system, a phylogenetically preserved area of the brain essential for preconscious awareness.

  1. The 10 Hz Frequency: A Fulcrum For Transitional Brain States

    PubMed Central

    Garcia-Rill, E.; D’Onofrio, S.; Luster, B.; Mahaffey, S.; Urbano, F. J.; Phillips, C.

    2016-01-01

    A 10 Hz rhythm is present in the occipital cortex when the eyes are closed (alpha waves), in the precentral cortex at rest (mu rhythm), in the superior and middle temporal lobe (tau rhythm), in the inferior olive (projection to cerebellar cortex), and in physiological tremor (underlying all voluntary movement). These are all considered resting rhythms in the waking brain which are “replaced” by higher frequency activity with sensorimotor stimulation. That is, the 10 Hz frequency fulcrum is replaced on the one hand by lower frequencies during sleep, or on the other hand by higher frequencies during volition and cognition. The 10 Hz frequency fulcrum is proposed as the natural frequency of the brain during quiet waking, but is replaced by higher frequencies capable of permitting more complex functions, or by lower frequencies during sleep and inactivity. At the center of the transition shifts to and from the resting rhythm is the reticular activating system, a phylogenetically preserved area of the brain essential for preconscious awareness. PMID:27547831

  2. Estimation of viscoelastic shear properties of vocal-fold tissues based on time-temperature superposition.

    PubMed

    Chan, R W

    2001-09-01

    Empirical data on the viscoelastic shear properties of human vocal-fold mucosa (cover) were recently reported at relatively low frequency (0.01-15 Hz). For the data to become relevant to voice production, attempts have been made to parametrize and extrapolate the data to higher frequencies using constitutive modeling [Chan and Titze, J. Acoust. Soc. Am. 107, 565-580 (2000)]. This study investigated the feasibility of an alternative approach for data extrapolation, namely the principle of time-temperature superposition (TTS). TTS is a hybrid theoretical-empirical approach widely used by rheologists to estimate the viscoelastic properties of polymeric systems at time or frequency scales not readily accessible experimentally. It is based on the observation that for many polymers, the molecular configurational changes that occur in a given time scale at a low temperature correspond to those that occur in a shorter time scale at a higher temperature. Using a rotational rheometer, the elastic shear modulus (G') and viscous shear modulus (G'') of vocal-fold cover (superficial layer of lamina propria) tissue samples were measured at 0.01-15 Hz at relatively low temperatures (5 degrees-37 degrees C). Data were empirically shifted according to TTS, yielding composite "master curves" for predicting the magnitude of the shear moduli at higher frequencies at 37 degrees C. Results showed that TTS may be a feasible approach for estimating the viscoelastic shear properties of vocal-fold tissues at frequencies of phonation (on the order of 100-1000 Hz).

  3. Extremely low-frequency electromagnetic fields cause DNA strand breaks in normal cells

    PubMed Central

    2014-01-01

    Background Extremely low frequency electromagnetic fields aren’t considered as a real carcinogenic agent despite the fact that some studies have showed impairment of the DNA integrity in different cells lines. The aim of this study was evaluation of the late effects of a 100 Hz and 5.6 mT electromagnetic field, applied continuously or discontinuously, on the DNA integrity of Vero cells assessed by alkaline Comet assay and by cell cycle analysis. Normal Vero cells were exposed to extremely low frequency electromagnetic fields (100 Hz, 5.6 mT) for 45 minutes. The Comet assay and cell cycle analysis were performed 48 hours after the treatment. Results Exposed samples presented an increase of the number of cells with high damaged DNA as compared with non-exposed cells. Quantitative evaluation of the comet assay showed a significantly (<0.001) increase of the tail lengths, of the quantity of DNA in tail and of Olive tail moments, respectively. Cell cycle analysis showed an increase of the frequency of the cells in S phase, proving the occurrence of single strand breaks. The most probable mechanism of induction of the registered effects is the production of different types of reactive oxygen species. Conclusions The analysis of the registered comet indices and of cell cycle showed that extremely low frequency electromagnetic field of 100 Hz and 5.6 mT had a genotoxic impact on Vero cells. PMID:24401758

  4. Fitting stress relaxation experiments with fractional Zener model to predict high frequency moduli of polymeric acoustic foams

    NASA Astrophysics Data System (ADS)

    Guo, Xinxin; Yan, Guqi; Benyahia, Lazhar; Sahraoui, Sohbi

    2016-11-01

    This paper presents a time domain method to determine viscoelastic properties of open-cell foams on a wide frequency range. This method is based on the adjustment of the stress-time relationship, obtained from relaxation tests on polymeric foams' samples under static compression, with the four fractional derivatives Zener model. The experimental relaxation function, well described by the Mittag-Leffler function, allows for straightforward prediction of the frequency-dependence of complex modulus of polyurethane foams. To show the feasibility of this approach, complex shear moduli of the same foams were measured in the frequency range between 0.1 and 16 Hz and at different temperatures between -20 °C and 20 °C. A curve was reconstructed on the reduced frequency range (0.1 Hz-1 MHz) using the time-temperature superposition principle. Very good agreement was obtained between experimental complex moduli values and the fractional Zener model predictions. The proposed time domain method may constitute an improved alternative to resonant and non-resonant techniques often used for dynamic characterization of polymers for the determination of viscoelastic moduli on a broad frequency range.

  5. Performance of the NASA Digitizing Core-Loss Instrumentation

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E. (Technical Monitor); Niedra, Janis M.

    2003-01-01

    The standard method of magnetic core loss measurement was implemented on a high frequency digitizing oscilloscope in order to explore the limits to accuracy when characterizing high Q cores at frequencies up to 1 MHz. This method computes core loss from the cycle mean of the product of the exciting current in a primary winding and induced voltage in a separate flux sensing winding. It is pointed out that just 20 percent accuracy for a Q of 100 core material requires a phase angle accuracy of 0.1 between the voltage and current measurements. Experiment shows that at 1 MHz, even high quality, high frequency current sensing transformers can introduce phase errors of a degree or more. Due to the fact that the Q of some quasilinear core materials can exceed 300 at frequencies below 100 kHz, phase angle errors can be a problem even at 50 kHz. Hence great care is necessary with current sensing and ground loops when measuring high Q cores. Best high frequency current sensing accuracy was obtained from a fabricated 0.1-ohm coaxial resistor, differentially sensed. Sample high frequency core loss data taken with the setup for a permeability-14 MPP core is presented.

  6. Spectrotemporal modulation sensitivity for hearing-impaired listeners: dependence on carrier center frequency and the relationship to speech intelligibility.

    PubMed

    Mehraei, Golbarg; Gallun, Frederick J; Leek, Marjorie R; Bernstein, Joshua G W

    2014-07-01

    Poor speech understanding in noise by hearing-impaired (HI) listeners is only partly explained by elevated audiometric thresholds. Suprathreshold-processing impairments such as reduced temporal or spectral resolution or temporal fine-structure (TFS) processing ability might also contribute. Although speech contains dynamic combinations of temporal and spectral modulation and TFS content, these capabilities are often treated separately. Modulation-depth detection thresholds for spectrotemporal modulation (STM) applied to octave-band noise were measured for normal-hearing and HI listeners as a function of temporal modulation rate (4-32 Hz), spectral ripple density [0.5-4 cycles/octave (c/o)] and carrier center frequency (500-4000 Hz). STM sensitivity was worse than normal for HI listeners only for a low-frequency carrier (1000 Hz) at low temporal modulation rates (4-12 Hz) and a spectral ripple density of 2 c/o, and for a high-frequency carrier (4000 Hz) at a high spectral ripple density (4 c/o). STM sensitivity for the 4-Hz, 4-c/o condition for a 4000-Hz carrier and for the 4-Hz, 2-c/o condition for a 1000-Hz carrier were correlated with speech-recognition performance in noise after partialling out the audiogram-based speech-intelligibility index. Poor speech-reception and STM-detection performance for HI listeners may be related to a combination of reduced frequency selectivity and a TFS-processing deficit limiting the ability to track spectral-peak movements.

  7. Testing the relativistic precession model using low-frequency and kHz quasi-periodic oscillations in neutron star low-mass X-ray binaries with known spin

    NASA Astrophysics Data System (ADS)

    van Doesburgh, Marieke; van der Klis, Michiel

    2017-03-01

    We analyse all available RXTE data on a sample of 13 low-mass X-ray binaries with known neutron star spin that are not persistent pulsars. We carefully measure the correlations between the centroid frequencies of the quasi-periodic oscillations (QPOs). We compare these correlations to the prediction of the relativistic precession model that, due to frame dragging, a QPO will occur at the Lense-Thirring precession frequency νLT of a test-particle orbit whose orbital frequency is the upper kHz QPO frequency νu. Contrary to the most prominent previous studies, we find two different oscillations in the range predicted for νLT that are simultaneously present over a wide range of νu. Additionally, one of the low-frequency noise components evolves into a (third) QPO in the νLT range when νu exceeds 600 Hz. The frequencies of these QPOs all correlate to νu following power laws with indices between 0.4 and 3.3, significantly exceeding the predicted value of 2.0 in 80 per cent of the cases (at 3 to >20σ). Also, there is no evidence that the neutron star spin frequency affects any of these three QPO frequencies, as would be expected for frame dragging. Finally, the observed QPO frequencies tend to be higher than the νLT predicted for reasonable neutron star specific moment of inertia. In the light of recent successes of precession models in black holes, we briefly discuss ways in which such precession can occur in neutron stars at frequencies different from test-particle values and consistent with those observed. A precessing torus geometry and other torques than frame dragging may allow precession to produce the observed frequency correlations, but can only explain one of the three QPOs in the νLT range.

  8. 47 CFR 15.109 - Radiated emission limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...

  9. 47 CFR 15.109 - Radiated emission limits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...

  10. 47 CFR 15.109 - Radiated emission limits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...

  11. 47 CFR 15.109 - Radiated emission limits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as... for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an... 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At...

  12. A comparison of auditory evoked potentials to acoustic beats and to binaural beats.

    PubMed

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2010-04-01

    The purpose of this study was to compare cortical brain responses evoked by amplitude modulated acoustic beats of 3 and 6 Hz in tones of 250 and 1000 Hz with those evoked by their binaural beats counterparts in unmodulated tones to indicate whether the cortical processes involved differ. Event-related potentials (ERPs) were recorded to 3- and 6-Hz acoustic and binaural beats in 2000 ms duration 250 and 1000 Hz tones presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to beats-evoked oscillations were determined and compared across beat types, beat frequencies and base (carrier) frequencies. All stimuli evoked tone-onset components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude in response to acoustic than to binaural beats, to 250 than to 1000 Hz base frequency and to 3 Hz than to 6 Hz beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left temporal lobe areas. Differences between estimated sources of potentials to acoustic and binaural beats were not significant. The perceptions of binaural beats involve cortical activity that is not different than acoustic beats in distribution and in the effects of beat- and base frequency, indicating similar cortical processing. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Noise attenuation characteristics of a foam type earplug measured using a dummy head.

    PubMed

    Idota, Nozomi; Horie, Seichi; Tsutsui, Takao; Inoue, Jinro

    2002-03-01

    The attenuation characteristics of the earplug using a dummy head (KEMAR; Knowles Electronics Manikin for Acoustic Research) were measured, when it was exposed to pure tones or broadband noises at three different sound pressure levels (SPLs) of 70, 80 and 90 dB SPL in the 'wide frequency range from 250 to 20 k Hz. We ascertained the satisfactory capacity of noise attenuation except for from 10 k to 14 k Hz. The noise attenuation level increased with frequency until 2 k Hz, became almost constant until 8 k Hz, then decreased at around 10 k to 14 k Hz, and recovered in the range from 16 k to 20 k Hz. The frequency characteristics were identical among three different sound pressure levels and almost identical between pure tones and broadband noises. The change of frequency characteristics affected by the depth of the earplug that was inserted into the artificial ear canal of the KEMAR was also investigated. Measured sound pressure level by the builetin microphone in the KEMAR revealed a region in which the measured sound pressure levels were relatively higher around 10 k Hz. The frequency of the region moved higher when the earplug was inserted more deeply. Therefore it was considered that this phenomenon was related to the resonance frequency of the cylinder-like cavity made between the end section of the earplug and the diaphragm of the built-in microphone.

  14. The Effects of Filter Cutoff Frequency on Musculoskeletal Simulations of High-Impact Movements.

    PubMed

    Tomescu, Sebastian; Bakker, Ryan; Beach, Tyson A C; Chandrashekar, Naveen

    2018-02-12

    Estimation of muscle forces through musculoskeletal simulation is important in understanding human movement and injury. Unmatched filter frequencies used to low-pass filter marker and force platform data can create artifacts during inverse dynamics analysis, but their effects on muscle force calculations are unknown. The objective of this study was to determine the effects of filter cutoff frequency on simulation parameters and magnitudes of lower extremity muscle and resultant joint contact forces during a high-impact maneuver. Eight participants performed a single leg jump-landing. Kinematics were captured with a 3D motion capture system and ground reaction forces were recorded with a force platform. The marker and force platform data were filtered using two matched filter frequencies (10-10Hz, 15-15Hz) and two unmatched frequencies (10-50Hz, 15-50Hz). Musculoskeletal simulations using Computed Muscle Control were performed in OpenSim. The results revealed significantly higher peak quadriceps (13%), hamstrings (48%), and gastrocnemius forces (69%) in the unmatched (10-50Hz, 15-50Hz) conditions than in the matched (10-10Hz, 15-15Hz) conditions (p<0.05). Resultant joint contact forces and reserve (non-physiologic) moments were similarly larger in the unmatched filter categories (p<0.05). This study demonstrated that artifacts created from filtering with unmatched filter cutoffs result in altered muscle forces and dynamics which are not physiologic.

  15. Observations of 50/60 Hz Power Line Radiation in the Low Latitude Ionosphere Detected by the Electric Field Instrument on the C/NOFS Satellite

    NASA Astrophysics Data System (ADS)

    Pfaff, R. F., Jr.; Freudenreich, H. T.; Simoes, F. A.; Liebrecht, M. C.; Farrell, W.

    2017-12-01

    One of the most ubiquitous forms of EM radiation emanating from the earth's surface is that of power line radiation. Associated with AC electric power generation, such emissions are typically launched along conducting power lines that may travel hundreds, or even thousands of km, from generating stations. The fundamental frequencies of such emissions are characteristically 50 Hz or 60 Hz, depending on the regional standards for power generation/consumption. The frequency of this radiation is well below that of the plasma frequency of the ionosphere (typically several MHz) and hence is expected to reflect back to the earth and propagate in the waveguide formed by the earth's surface and the bottom ledge of the ionosphere, typically near 100 km. Given that such power lines are widespread on the exposed lithosphere, the leakage of some ELF emissions associated with electric power generation might nevertheless be expected in the ionosphere, in the same manner in which a small fraction of the power associated with ELF Schumann resonances and lightning sferics have been shown to penetrate into the ionosphere. We present direct measurements of 50/60 Hz power line radiation detected by in situ probes on an orbiting satellite in the earth's ionosphere. The data were gathered by the Vector Electric Field Investigation (VEFI) tri-axial double probe detector flown on the Communication/Navigation Outage Forecast System (C/NOFS) satellite. C/NOFS was launched in April, 2008 into a low latitude (13 deg inclination) orbit with perigee and apogee of 400 km and 850 km, respectively. The electric field wave data were gathered by ELF receivers comprised of two orthogonal broadband channels sampled at 512 s/sec each, and digitized with 16 bit A/D converters. The data show distinct 60 Hz emissions while the satellite sampled within the Brazilian sector whereas distinct 50 Hz emissions were detected over India. Other, less distinct, emissions were observed over Africa and southeast Asia. We discuss the characteristics of the received emissions, including their amplitudes and spectral features (i.e., harmonics). We use these observations to advance our understanding of how natural terrestrial ELF emissions, such as those associated with Schumann resonances and lightning, penetrate into the ionosphere.

  16. Stratifying Parkinson's Patients With STN-DBS Into High-Frequency or 60 Hz-Frequency Modulation Using a Computational Model.

    PubMed

    Khojandi, Anahita; Shylo, Oleg; Mannini, Lucia; Kopell, Brian H; Ramdhani, Ritesh A

    2017-07-01

    High frequency stimulation (HFS) of the subthalamic nucleus (STN) is a well-established therapy for Parkinson's disease (PD), particularly the cardinal motor symptoms and levodopa induced motor complications. Recent studies have suggested the possible role of 60 Hz stimulation in STN-deep brain stimulation (DBS) for patients with gait disorder. The objective of this study was to develop a computational model, which stratifies patients a priori based on symptomatology into different frequency settings (i.e., high frequency or 60 Hz). We retrospectively analyzed preoperative MDS-Unified Parkinson's Disease Rating Scale III scores (32 indicators) collected from 20 PD patients implanted with STN-DBS at Mount Sinai Medical Center on either 60 Hz stimulation (ten patients) or HFS (130-185 Hz) (ten patients) for an average of 12 months. Predictive models using the Random Forest classification algorithm were built to associate patient/disease characteristics at surgery to the stimulation frequency. These models were evaluated objectively using leave-one-out cross-validation approach. The computational models produced, stratified patients into 60 Hz or HFS (130-185 Hz) with 95% accuracy. The best models relied on two or three predictors out of the 32 analyzed for classification. Across all predictors, gait and rest tremor of the right hand were consistently the most important. Computational models were developed using preoperative clinical indicators in PD patients treated with STN-DBS. These models were able to accurately stratify PD patients into 60 Hz stimulation or HFS (130-185 Hz) groups a priori, offering a unique potential to enhance the utilization of this therapy based on clinical subtypes. © 2017 International Neuromodulation Society.

  17. Non-linearity of visual evoked potentials in cerveau isolé and midpontine pretrigeminal cats.

    PubMed

    Shibagaki, M; Kiyono, S; Kawashima, T; Watanabe, S

    1985-01-01

    Characteristics of the visual evoked responses to the flickering flash stimulation were studied in the cerveau isolé and midpontine pretrigeminal cats. The flash stimulation frequency was changed stepwise between 1 and 30 Hz in increasing and decreasing order. In all cases of both preparations, with drawing of fixed sweep speed of 200 msec in whole length, P1 and N1 latencies in the successive response slightly prolonged progressively 1 to about 20 Hz and thereafter shortened about 20-30 Hz stimulus frequencies in the course of the increasing phase, and vice versa in the course of the decreasing phase. Moreover, no difference in each latency (P1, N1, P2, N2) was found at the same stimulus frequency during increasing and decreasing phases. In the amplitude taken from the P1-N1 component, the peak was found in 5-9 Hz frequency bands. This peak was higher during the decreasing phase than during the increasing phase, which indicated a hysteresis phenomenon. A peak of power for the 1st harmonics was found at 3-6 Hz driving frequency bands, and that of the 2nd harmonics at 6-10 Hz. In the state without flash stimulus, no peaks or valleys in the power spectrum were found in specific frequencies, for example 3-10 Hz. The peak in the amplitude and that in the power spectrum at 3-10 Hz stimulus frequency bands suggested an entrainment phenomenon induced by forced oscillation. The phenomena of entrainment and hysteresis suggest the existence of a non-linear structure in the oscillation generating systems of visual evoked response.

  18. Wide Temperature Magnetization Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Schwarze, Gene E.

    1999-01-01

    100 kHz magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. Basic exciting winding current and induced voltage data were taken on bare toroidal cores, in a standard type measurement setup. A linear permeability model, which represents the core by a parallel L-R circuit, is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials are reviewed. The 100 kHz permeability thus derived decreases with increasing temperature for the Fe-based, nanocrystalline material, but increases roughly linearly with temperature for the two Co-based materials, as long as B(sub peak) is sufficiently low to avoid saturation effects. Due to the high permeabilities, rather low values of the 'quality factor' Q, from about 20 to below unity, were obtained over the frequency range of 50 kHz to 1 MHz (50 C, B(sub peak) = 0.1 T). Therefore these cores must be gapped in order to make up high Q or high current inductors. However, being rugged, low core loss materials with flat B-H loop characteristics, they may provide new solutions to specialty inductor applications.

  19. Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Kemery, Amy; Camp, Jordan

    2005-01-01

    We evaluated thermal noise (Brownian motion) in a rigid reference cavity Used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with the direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency-reference cavity of order 1 Hz/rtHz at 10mHz at room temperature. This level coincides with the world-highest level stabilization results.

  20. Attention and Working Memory-Related EEG Markers of Subtle Cognitive Deterioration in Healthy Elderly Individuals.

    PubMed

    Deiber, Marie-Pierre; Meziane, Hadj Boumediene; Hasler, Roland; Rodriguez, Cristelle; Toma, Simona; Ackermann, Marine; Herrmann, François; Giannakopoulos, Panteleimon

    2015-01-01

    Future treatments of Alzheimer's disease need the identification of cases at high risk at the preclinical stage of the disease before the development of irreversible structural damage. We investigated here whether subtle cognitive deterioration in a population of healthy elderly individuals could be predicted by EEG signals at baseline under cognitive activation. Continuous EEG was recorded in 97 elderly control subjects and 45 age-matched mild cognitive impairment (MCI) cases during a simple attentional and a 2-back working memory task. Upon 18-month neuropsychological follow-up, the final sample included 55 stable (sCON) and 42 deteriorated (dCON) controls. We examined the P1, N1, P3, and PNwm event-related components as well as the oscillatory activities in the theta (4-7 Hz), alpha (8-13 Hz), and beta (14-25 Hz) frequency ranges (ERD/ERS: event-related desynchronization/synchronization, and ITC: inter-trial coherence). Behavioral performance, P1, and N1 components were comparable in all groups. The P3, PNwm, and all oscillatory activity indices were altered in MCI cases compared to controls. Only three EEG indices distinguished the two control groups: alpha and beta ERD (dCON >  sCON) and beta ITC (dCON <  sCON). These findings show that subtle cognitive deterioration has no impact on EEG indices associated with perception, discrimination, and working memory processes but mostly affects attention, resulting in an enhanced recruitment of attentional resources. In addition, cognitive decline alters neural firing synchronization at high frequencies (14-25 Hz) at early stages, and possibly affects lower frequencies (4-13 Hz) only at more severe stages.

  1. 77 FR 49412 - Takes of Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-16

    ...; high-pitched sounds contain high frequencies and low-pitched sounds contain low frequencies. Natural... estimated to occur between approximately 150 Hz and 160 kHz. High-frequency cetaceans (eight species of true... masking by high frequency sound. Human data indicate low-frequency sound can mask high-frequency sounds (i...

  2. Effects of ultrasound frequency and tissue stiffness on the histotripsy intrinsic threshold for cavitation.

    PubMed

    Vlaisavljevich, Eli; Lin, Kuang-Wei; Maxwell, Adam; Warnez, Matthew T; Mancia, Lauren; Singh, Rahul; Putnam, Andrew J; Fowlkes, Brian; Johnsen, Eric; Cain, Charles; Xu, Zhen

    2015-06-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has indicated that a cavitation cloud can be formed by a single pulse with one high-amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue, and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1-2 cycles produced by 345-kHz, 500-kHz, 1.5-MHz and 3-MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured versus pressure amplitude. The results revealed that the intrinsic threshold (the negative pressure at which probability = 0.5) is independent of stiffness for Young's moduli (E) <1 MPa, with only a small increase (∼2-3 MPa) in the intrinsic threshold for tendon (E = 380 MPa). Additionally, results for all samples revealed only a small increase of ∼2-3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7 and 30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly affected by tissue stiffness or ultrasound frequency in the hundreds of kilohertz to megahertz range. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Electrochemical characterization of high frequency stimulation electrodes: role of electrode material and stimulation parameters on electrode polarization

    NASA Astrophysics Data System (ADS)

    Ghazavi, Atefeh; Cogan, Stuart F.

    2018-06-01

    Objective. With recent interest in kilohertz frequency electrical stimulation for nerve conduction block, understanding the electrochemistry and role of electrode material is important for assessing the safety of these stimulus protocols. Here we describe an approach to determining electrode polarization in response to continuous kilohertz frequency sinusoidal current waveforms. We have also investigated platinum, iridium oxide, and titanium nitride as coatings for high frequency electrodes. The current density distribution at 50 kHz at the electrode–electrolyte interface was also modeled to demonstrate the importance of the primary current distribution in supporting charge injection at high frequencies. Approach. We determined electrode polarization in response to sinusoidal currents with frequencies in the 1–50 kHz range and current amplitudes from 100 to 500 µA and 1–5 mA, depending on the electrode area. The current density distribution at the interface was modeled using the finite element method (FEM). Main results. At low frequencies, 1–5 kHz, polarization on the platinum electrode was significant, exceeding the water oxidation potential for high amplitude (5 mA) waveforms. At frequencies of 20 kHz or higher, the polarization was less than 300 mV from the electrode open circuit potential. The choice of electrode material did not play a significant role in electrode polarization at frequencies higher than 10 kHz. The current density distribution modeled at 50 kHz is non-uniform and this non-uniformity persists throughout charge delivery. Significance. At high frequencies (>10 kHz) electrode double-layer charging is the principal mechanism of charge-injection and selection of the electrode material has little effect on polarization, with platinum, iridium oxide, and titanium nitride exhibiting similar behavior. High frequency stimulation is dominated by a highly nonuniform primary current distribution.

  4. Reinterpreting features of the advertisement call of Dermatonotus muelleri (Boettger, 1885; Anura, Microhylidae).

    PubMed

    Giaretta, Ariovaldo Antonio; Vo, Pacific; Herche, Jesse; Tang, Justine Nicole; Gridi-Papp, Marcos

    2015-06-13

    The advertisement call of Dermatonotus muelleri was originally described by Nelson (1973) in a brief section of a review on the mating calls of the Microhylinae. He used two calls from São Leopoldo, state of Minas Gerais, in Brazil to determine that they have i) dominant frequency between 1.500-2.200 kHz (mean 1.854 + 0.216 kHz), and ii) harmonic intervals between 0.140 and 0.150 kHz (0.146 +/- 0.005 kHz). Nelson (1973) based his description on an audiospectrogram produced with high frequency resolution and did not quantify the pulse structure of the calls. More recently, Giaretta and colleagues (2013) expanded on the original description using a larger set of calls recorded from Gurinhat, state of Minas Gerais, in Brazil. They quantified the temporal structure of the call and confirmed that the dominant frequency is around 1.8 kHz. In addition, they identified a secondary low frequency band at 667 Hz.

  5. Individual Alpha Peak Frequency Predicts 10 Hz Flicker Effects on Selective Attention.

    PubMed

    Gulbinaite, Rasa; van Viegen, Tara; Wieling, Martijn; Cohen, Michael X; VanRullen, Rufin

    2017-10-18

    Rhythmic visual stimulation ("flicker") is primarily used to "tag" processing of low-level visual and high-level cognitive phenomena. However, preliminary evidence suggests that flicker may also entrain endogenous brain oscillations, thereby modulating cognitive processes supported by those brain rhythms. Here we tested the interaction between 10 Hz flicker and endogenous alpha-band (∼10 Hz) oscillations during a selective visuospatial attention task. We recorded EEG from human participants (both genders) while they performed a modified Eriksen flanker task in which distractors and targets flickered within (10 Hz) or outside (7.5 or 15 Hz) the alpha band. By using a combination of EEG source separation, time-frequency, and single-trial linear mixed-effects modeling, we demonstrate that 10 Hz flicker interfered with stimulus processing more on incongruent than congruent trials (high vs low selective attention demands). Crucially, the effect of 10 Hz flicker on task performance was predicted by the distance between 10 Hz and individual alpha peak frequency (estimated during the task). Finally, the flicker effect on task performance was more strongly predicted by EEG flicker responses during stimulus processing than during preparation for the upcoming stimulus, suggesting that 10 Hz flicker interfered more with reactive than proactive selective attention. These findings are consistent with our hypothesis that visual flicker entrained endogenous alpha-band networks, which in turn impaired task performance. Our findings also provide novel evidence for frequency-dependent exogenous modulation of cognition that is determined by the correspondence between the exogenous flicker frequency and the endogenous brain rhythms. SIGNIFICANCE STATEMENT Here we provide novel evidence that the interaction between exogenous rhythmic visual stimulation and endogenous brain rhythms can have frequency-specific behavioral effects. We show that alpha-band (10 Hz) flicker impairs stimulus processing in a selective attention task when the stimulus flicker rate matches individual alpha peak frequency. The effect of sensory flicker on task performance was stronger when selective attention demands were high, and was stronger during stimulus processing and response selection compared with the prestimulus anticipatory period. These findings provide novel evidence that frequency-specific sensory flicker affects online attentional processing, and also demonstrate that the correspondence between exogenous and endogenous rhythms is an overlooked prerequisite when testing for frequency-specific cognitive effects of flicker. Copyright © 2017 the authors 0270-6474/17/3710173-12$15.00/0.

  6. 47 CFR 87.149 - Special requirements for automatic link establishment (ALE).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... exceed 100 W ERP; (b) Transmissions must sweep linearly in frequency at a rate of at least 60 kHz per... frequencies and frequency bands must not exceed 10 µW peak ERP: (1) Protected frequencies (kHz) 2091.0 4188.0...

  7. Frequency-Dependence of Relative Permeability in Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowler, N.

    2006-03-06

    A study to characterize metal plates by means of a model-based, broadband, four-point potential drop measurement technique has shown that the relative permeability of alloy 1018 low-carbon steel is complex and a function of frequency. A magnetic relaxation is observed at approximately 5 kHz. The relaxation can be described in terms of a parametric (Cole-Cole) model. Factors which influence the frequency, amplitude and breadth of the relaxation, such as applied current amplitude, sample geometry and disorder (e.g. percent carbon content and surface condition), are considered.

  8. Dependence the Integrated Energy of the Electromagnetic Response from Excitation Pulse Duration for Epoxy Samples With Sand Filler

    NASA Astrophysics Data System (ADS)

    Surzhikov, V. P.; Demikhova, A. A.

    2017-01-01

    Results of research of influence of the excitation pulse duration on the parameters of the electromagnetic response of epoxy samples with filler the quartz sand presented in the paper. The electric component of a response was registered by the capacitive sensors using a differential amplifier. Measurements were carried out at two frequencies of the master generator of 65 kHz and 74 kHz. The pulse duration was changing from 10 to 100 microseconds. The stepped sort of dependence of the integrated oscillations energy in the response from duration of the excitation pulse was discovered. The conclusion was made about the determining role of the normal oscillations in formation of such dependence.

  9. Machine Learning-Aided, Robust Wideband Spectrum Sensing for Cognitive Radios

    DTIC Science & Technology

    2015-06-12

    to even Approved for public release; distribution is unlimited. 2 on the order of a giga -Hertz (GHz). Due to wide bandwidth and noncontiguous...Frequency Band CS Compressive Sampling DFT Discrete Fourier Transform EMI Electro Magnetic Interference FFT Fast Fourier Transform GHz Giga Hertz Hz Hertz

  10. 78 FR 29705 - Takes of Marine Mammals Incidental to Specified Activities; Taking Marine Mammals Incidental to a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-21

    ..., the basic components of which are frequency, wavelength, velocity, and amplitude. Frequency is the... frequency sounds have longer wavelengths than higher frequency sounds and attenuate more rapidly in... occurring ambient noise for frequencies between 200 Hz and 50 kHz (Mitson, 1995). In general, ambient noise...

  11. Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment.

    PubMed

    Huang, Xiaolei; Dong, Hui; Qiu, Yang; Li, Bo; Tao, Quan; Zhang, Yi; Krause, Hans-Joachim; Offenhäusser, Andreas; Xie, Xiaoming

    2018-01-01

    Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra-low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel(s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. An experimental study of the effects of water repellant treatment on the acoustic properties of Kevlar

    NASA Technical Reports Server (NTRS)

    Smith, C. D.; Parrott, T. L.

    1978-01-01

    The treatment consisted of immersing samples of Kevlar in a solution of distilled water and Zepel. The samples were then drained, dried in a circulating over, and cured. Flow resistance tests showed approximately one percent decrease in flow resistance of the samples. Also there was a density increase of about three percent. It was found that the treatment caused a change in the texture of the samples. There were significant changes in the acoustic properties of the treated Kevlar over the frequency range 0.5 to 3.5 kHz. In general it was found that the propagation constant and characteristic impedance increased with increasing frequency. The real and imaginary components of the propagation constant for the treated Kevlar exhibited a decrease of 8 to 12 percent relative to that for the untreated Kevlar at the higher frequencies. The magnitude of the reactance component of the characteristic impedance decreased by about 40 percent at the higher frequencies.

  13. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    NASA Technical Reports Server (NTRS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  14. Re-Active Passive devices for control of noise transmission through a panel

    NASA Astrophysics Data System (ADS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  15. MESSENGER Magnetic Field Observations of Upstream Ultra-Low Frequency Waves at Mercury

    NASA Technical Reports Server (NTRS)

    Le, G.; Chi, P. J.; Boardsen, S.; Blanco-Cano, X.; Anderosn, B. J.; Korth, H.

    2012-01-01

    The region upstream from a planetary bow shock is a natural plasma laboratory containing a variety of wave particle phenomena. The study of foreshocks other than the Earth's is important for extending our understanding of collisionless shocks and foreshock physics since the bow shock strength varies with heliocentric distance from the Sun, and the sizes of the bow shocks are different at different planets. The Mercury's bow shock is unique in our solar system as it is produced by low Mach number solar wind blowing over a small magnetized body with a predominately radial interplanetary magnetic field. Previous observations of Mercury upstream ultra-low frequency (ULF) waves came exclusively from two Mercury flybys of Mariner 10. The MESSENGER orbiter data enable us to study of upstream waves in the Mercury's foreshock in depth. This paper reports an overview of upstream ULF waves in the Mercury's foreshock using high-time resolution magnetic field data, 20 samples per second, from the MESSENGER spacecraft. The most common foreshock waves have frequencies near 2 Hz, with properties similar to the I-Hz waves in the Earth's foreshock. They are present in both the flyby data and in every orbit of the orbital data we have surveyed. The most common wave phenomenon in the Earth's foreshock is the large-amplitude 30-s waves, but similar waves at Mercury have frequencies at near 0.1 Hz and occur only sporadically with short durations (a few wave cycles). Superposed on the "30-s" waves, there are spectral peaks at near 0.6 Hz, not reported previously in Mariner 10 data. We will discuss wave properties and their occurrence characteristics in this paper.

  16. Vibration of the human tympanic membrane measured with OCT in a range between 0.4 kHz and 6.4 kHz on an ex vivo sample

    NASA Astrophysics Data System (ADS)

    Burkhardt, Anke; Kirsten, Lars; Bornitz, Matthias; Zahnert, Thomas; Koch, Edmund

    2013-06-01

    Vibrations of the tympanic membrane (TM) play a key role for the transmission of sound to the inner ear. Today, there exist still problems in measuring the movement of the TM and there are unresolved issues in understanding the TM and its behavior. A non-invasive and contact-free in vivo investigation of the structure and the functional behavior of the TM would be a big step forward. In the presented study, the suitability of optical coherence tomography (OCT) for measuring the oscillation patterns of the TM in the frequency range covering the range of the human speech perception should be tested. For functional imaging a sound chirp was generated in the frequency range between 0.4 kHz - 6.4 kHz. To obtain the movement within a sufficient resolution, a grid of 25 x 25 measurement points was generated over the whole TM. The information of the oscillatory movement was encoded in the Doppler signal, provided by M-scans at several points of the TM. The frequency response functions of each frequency showed different oscillation patterns on the TM. The acquisition time of one single M-scan was only 8.5 ms and of the entire TM 5.3 s, emphasizing the potential of the method for future in vivo applications. Furthermore, the morphology was acquired with the same OCT-system, showing the feasibility for structural imaging and differentiation between typical regions of the TM. Thus, OCT was shown as a suitable method for the simultaneous measurement of the functional and structural behavior of the TM.

  17. Evaluation of cochlear function in normal-hearing young adults exposed to MP3 player noise by analyzing transient evoked otoacoustic emissions and distortion products.

    PubMed

    Santaolalla Montoya, Francisco; Ibargüen, Agustín Martinez; Vences, Ana Rodriguez; del Rey, Ana Sanchez; Fernandez, Jose Maria Sanchez

    2008-10-01

    Exposure to recreational noise may cause injuries to the inner ear, and transient evoked (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) may identify these cochlear alterations. The goal of this study was to evaluate TEOAEs and DPOAEs as a method to diagnose early cochlear alterations in young adults exposed to MP3 player noise. We performed a prospective study of the cochlear function in normal-hearing MP3 player users by analyzing TEOAE and DPOAE incidence, amplitude, and spectral content. We gathered a sample of 40 ears from patients between 19 and 29 years old (mean age 24.09 years, SD 3.9 years). We compared the results with those of a control group of 232 ears not exposed to MP3 noise from patients aged 18 to 32 years (mean age 23.35 years, SD 2.7 years). Fifty percent of ears were from females and 50% were from males. Subjects who had used MP3 players for most years and for more hours each week exhibited a reduction in TEOAE and DPOAE incidence and amplitudes and an increase in DPOAE thresholds. TEOAEs showed a statistically significant lower incidence and amplitudes for normal-hearing subjects using MP3 players at frequencies of 2000, 3000, and 4000 Hz. DPOAE incidence was lower at 700, 1000, 1500, and 2000 Hz; the amplitudes were lower at frequencies between 1500 and 6000 Hz; and the thresholds were higher for all frequency bands, statistically significant at frequencies from 1500 to 6000 Hz, p < .05. Cochlear impairment caused by MP3 player noise exposure may be detectable by analyzing TEOAEs and DPOAEs before the impairment becomes clinically apparent.

  18. Modelling natural electromagnetic interference in man-made conductors for space weather applications

    NASA Astrophysics Data System (ADS)

    Trichtchenko, Larisa

    2016-04-01

    Power transmission lines above the ground, cables and pipelines in the ground and under the sea, and in general all man-made long grounded conductors are exposed to the variations of the natural electromagnetic field. The resulting currents in the networks (commonly named geomagnetically induced currents, GIC), are produced by the conductive and/or inductive coupling and can compromise or even disrupt system operations and, in extreme cases, cause power blackouts, railway signalling mis-operation, or interfere with pipeline corrosion protection systems. To properly model the GIC in order to mitigate their impacts it is necessary to know the frequency dependence of the response of these systems to the geomagnetic variations which naturally span a wide frequency range. For that, the general equations of the electromagnetic induction in a multi-layered infinitely long cylinder (representing cable, power line wire, rail or pipeline) embedded in uniform media have been solved utilising methods widely used in geophysics. The derived electromagnetic fields and currents include the effects of the electromagnetic properties of each layer and of the different types of the surrounding media. This exact solution then has been used to examine the electromagnetic response of particular samples of long conducting structures to the external electromagnetic wave for a wide range of frequencies. Because the exact solution has a rather complicated structure, simple approximate analytical formulas have been proposed, analysed and compared with the results from the exact model. These approximate formulas show good coincidence in the frequency range spanning from geomagnetic storms (less than mHz) to pulsations (mHz to Hz) to atmospherics (kHz) and above, and can be recommended for use in space weather applications.

  19. A Combination Tissue Engineering Strategy for Schwann Cell-Induced Spinal Cord Repair

    DTIC Science & Technology

    2015-10-01

    the mechanical perturbation (2-3Hz) in both samples, however, there is much more power in the PVDF-TrEE sample overall. The frequency spectra for the...aligned-fibers contain signal power above and beyond the first and second harmonics of the mechanical stimulus, unlike the control sample on the...right. This finding shows that the 8 aligned PVDF-TrFE fibers generate field potentials that show up at higher harmonics of the mechanical

  20. Responses of Middle-Frequency Modulations in Vocal Fundamental Frequency to Different Vocal Intensities and Auditory Feedback.

    PubMed

    Lee, Shao-Hsuan; Fang, Tuan-Jen; Yu, Jen-Fang; Lee, Guo-She

    2017-09-01

    Auditory feedback can make reflexive responses on sustained vocalizations. Among them, the middle-frequency power of F0 (MFP) may provide a sensitive index to access the subtle changes in different auditory feedback conditions. Phonatory airflow temperature was obtained from 20 healthy adults at two vocal intensity ranges under four auditory feedback conditions: (1) natural auditory feedback (NO); (2) binaural speech noise masking (SN); (3) bone-conducted feedback of self-generated voice (BAF); and (4) SN and BAF simultaneously. The modulations of F0 in low-frequency (0.2 Hz-3 Hz), middle-frequency (3 Hz-8 Hz), and high-frequency (8 Hz-25 Hz) bands were acquired using power spectral analysis of F0. Acoustic and aerodynamic analyses were used to acquire vocal intensity, maximum phonation time (MPT), phonatory airflow, and MFP-based vocal efficiency (MBVE). SN and high vocal intensity decreased MFP and raised MBVE and MPT significantly. BAF showed no effect on MFP but significantly lowered MBVE. Moreover, BAF significantly increased the perception of voice feedback and the sensation of vocal effort. Altered auditory feedback significantly changed the middle-frequency modulations of F0. MFP and MBVE could well detect these subtle responses of audio-vocal feedback. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. A whole body vibration perception map and associated acceleration loads at the lower leg, hip and head.

    PubMed

    Sonza, Anelise; Völkel, Nina; Zaro, Milton A; Achaval, Matilde; Hennig, Ewald M

    2015-07-01

    Whole-body vibration (WBV) training has become popular in recent years. However, WBV may be harmful to the human body. The goal of this study was to determine the acceleration magnitudes at different body segments for different frequencies of WBV. Additionally, vibration sensation ratings by subjects served to create perception vibration magnitude and discomfort maps of the human body. In the first of two experiments, 65 young adults mean (± SD) age range of 23 (± 3.0) years, participated in WBV severity perception ratings, based on a Borg scale. Measurements were performed at 12 different frequencies, two intensities (3 and 5 mm amplitudes) of rotational mode WBV. On a separate day, a second experiment (n = 40) included vertical accelerometry of the head, hip and lower leg with the same WBV settings. The highest lower limb vibration magnitude perception based on the Borg scale was extremely intense for the frequencies between 21 and 25 Hz; somewhat hard for the trunk region (11-25 Hz) and fairly light for the head (13-25 Hz). The highest vertical accelerations were found at a frequency of 23 Hz at the tibia, 9 Hz at the hip and 13 Hz at the head. At 5 mm amplitude, 61.5% of the subjects reported discomfort in the foot region (21-25 Hz), 46.2% for the lower back (17, 19 and 21 Hz) and 23% for the abdominal region (9-13 Hz). The range of 3-7 Hz represents the safest frequency range with magnitudes less than 1 g(*)sec for all studied regions. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Optimization of Surveys with Internet Operated Deep-sea Crawlers, as an Integrated Tool for Ocean Cabled Observatories: Monitoring the Benthic Community of a Methane Hydrates Site in Barkley Canyon (BC, Canada)

    NASA Astrophysics Data System (ADS)

    Chatzievangelou, D.; Suarez, A.; Aguzzi, J.; Bigham, K.; Thomsen, L.

    2017-12-01

    Deep-sea research is entering an era of coordinated, multidisciplinary monitoring of benthic ecosystems, from local and regional to global scale. Technological advances, such as the development of ocean cabled observatories and mobile vehicles operating within them, raise the issue of "smart" study designs. The objective is optimizing the balance among reduced effort (i.e. sampling, data transfer and storage, a posteriori treatment), accurate representation of the monitored ecosystems and a minimal ecological footprint. For this study, 18 linear imaging transects ( 25 m each, 1 Hz frequency) were performed by the Internet Operated Deep-sea Crawler "Wally" at the Barkley Canyon hydrates site (870 m depth) within the Ocean Networks Canada NEPTUNE observatory, generating a total of 19920 images. In order to evaluate sampling effort, species accumulation curves were calculated against the number of transects, and the permanence time of mobile individuals in the crawler's field of view was used to assess the number of individuals captured for different potential imaging frequencies. The effect of the crawler caterpillars on benthic organisms was evaluated by comparing the images of disturbed (i.e previous tracks) vs. undisturbed seabed. The analyses showed that maximum species richness (i.e. 18 species) was achieved after 10 transects, while 0.33 Hz and 0.5 Hz imaging frequencies captured more than 95% of the individuals counted with the original 1 Hz method. Preliminary results indicate no differences in the numbers of benthic animals between the disturbed and the undisturbed seabed parts. These findings allow the design of future experiments under similar conditions with minimized costs and effort without compromising data quality. Finally, the low invasiveness of the crawler as a monitoring platform, as long as certain protocols are followed, is highlighted. Ongoing analyses of the same transects assess the varying macro- and megafauna, in relation to the distance from a nearby, small ( 2-3 m high) hydrate mound.

  3. Effects of Sound Frequency on Audiovisual Integration: An Event-Related Potential Study.

    PubMed

    Yang, Weiping; Yang, Jingjing; Gao, Yulin; Tang, Xiaoyu; Ren, Yanna; Takahashi, Satoshi; Wu, Jinglong

    2015-01-01

    A combination of signals across modalities can facilitate sensory perception. The audiovisual facilitative effect strongly depends on the features of the stimulus. Here, we investigated how sound frequency, which is one of basic features of an auditory signal, modulates audiovisual integration. In this study, the task of the participant was to respond to a visual target stimulus by pressing a key while ignoring auditory stimuli, comprising of tones of different frequencies (0.5, 1, 2.5 and 5 kHz). A significant facilitation of reaction times was obtained following audiovisual stimulation, irrespective of whether the task-irrelevant sounds were low or high frequency. Using event-related potential (ERP), audiovisual integration was found over the occipital area for 0.5 kHz auditory stimuli from 190-210 ms, for 1 kHz stimuli from 170-200 ms, for 2.5 kHz stimuli from 140-200 ms, 5 kHz stimuli from 100-200 ms. These findings suggest that a higher frequency sound signal paired with visual stimuli might be early processed or integrated despite the auditory stimuli being task-irrelevant information. Furthermore, audiovisual integration in late latency (300-340 ms) ERPs with fronto-central topography was found for auditory stimuli of lower frequencies (0.5, 1 and 2.5 kHz). Our results confirmed that audiovisual integration is affected by the frequency of an auditory stimulus. Taken together, the neurophysiological results provide unique insight into how the brain processes a multisensory visual signal and auditory stimuli of different frequencies.

  4. Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS

    NASA Astrophysics Data System (ADS)

    Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru

    2016-04-01

    The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2-8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied.

  5. On the Nature of the mHz X-ray Quasi-Periodic Oscillations from Ultraluminous X-ray source M82 X-1: Search for Timing-Spectral Correlations

    NASA Technical Reports Server (NTRS)

    Pasham, Dheeraj R.; Strohmayer, Tod E.

    2013-01-01

    Using all the archival XMM-Newton X-ray (3-10 keV) observations of the ultraluminous X-ray source (ULX) M82 X-1, we searched for a correlation between its variable mHz quasi-periodic oscillation (QPO) frequency and its hardness ratio (5-10 keV/3-5 keV), an indicator of the energy spectral power-law index. When stellar-mass black holes (StMBHs) exhibit type-C low-frequency QPOs (0.2-15 Hz), the centroid frequency of the QPO is known to correlate with the energy spectral index. The detection of such a correlation would strengthen the identification of M82 X-1's mHz QPOs as type-C and enable a more reliable mass estimate by scaling its QPO frequencies to those of type-C QPOs in StMBHs of known mass.We resolved the count rates and the hardness ratios of M82 X-1 and a nearby bright ULX (source 5/X42.3+59) through surface brightness modeling.We detected QPOs in the frequency range of 36-210 mHz during which M82 X-1's hardness ratio varied from 0.42 to 0.47. Our primary results are (1) that we do not detect any correlation between the mHz QPO frequency and the hardness ratio (a substitute for the energy spectral power-law index) and (2) similar to some accreting X-ray binaries, we find that M82 X-1's mHz QPO frequency increases with its X-ray count rate (Pearson's correlation coefficient = +0.97). The apparent lack of a correlation between the QPO centroid frequency and the hardness ratio poses a challenge to the earlier claims that the mHz QPOs of M82 X-1 are the analogs of the type-C low-frequency QPOs of StMBHs. On the other hand, it is possible that the observed relation between the hardness ratio and the QPO frequency represents the saturated portion of the correlation seen in type-C QPOs of StMBHs-in which case M82 X-1's mHz QPOs can still be analogous to type-C QPOs.

  6. Did You Listen to the Beat? Auditory Steady-State Responses in the Human Electroencephalogram at 4 and 7 Hz Modulation Rates Reflect Selective Attention.

    PubMed

    Jaeger, Manuela; Bleichner, Martin G; Bauer, Anna-Katharina R; Mirkovic, Bojana; Debener, Stefan

    2018-02-27

    The acoustic envelope of human speech correlates with the syllabic rate (4-8 Hz) and carries important information for intelligibility, which is typically compromised in multi-talker, noisy environments. In order to better understand the dynamics of selective auditory attention to low frequency modulated sound sources, we conducted a two-stream auditory steady-state response (ASSR) selective attention electroencephalogram (EEG) study. The two streams consisted of 4 and 7 Hz amplitude and frequency modulated sounds presented from the left and right side. One of two streams had to be attended while the other had to be ignored. The attended stream always contained a target, allowing for the behavioral confirmation of the attention manipulation. EEG ASSR power analysis revealed a significant increase in 7 Hz power for the attend compared to the ignore conditions. There was no significant difference in 4 Hz power when the 4 Hz stream had to be attended compared to when it had to be ignored. This lack of 4 Hz attention modulation could be explained by a distracting effect of a third frequency at 3 Hz (beat frequency) perceivable when the 4 and 7 Hz streams are presented simultaneously. Taken together our results show that low frequency modulations at syllabic rate are modulated by selective spatial attention. Whether attention effects act as enhancement of the attended stream or suppression of to be ignored stream may depend on how well auditory streams can be segregated.

  7. Spectrotemporal modulation sensitivity for hearing-impaired listeners: Dependence on carrier center frequency and the relationship to speech intelligibility

    PubMed Central

    Mehraei, Golbarg; Gallun, Frederick J.; Leek, Marjorie R.; Bernstein, Joshua G. W.

    2014-01-01

    Poor speech understanding in noise by hearing-impaired (HI) listeners is only partly explained by elevated audiometric thresholds. Suprathreshold-processing impairments such as reduced temporal or spectral resolution or temporal fine-structure (TFS) processing ability might also contribute. Although speech contains dynamic combinations of temporal and spectral modulation and TFS content, these capabilities are often treated separately. Modulation-depth detection thresholds for spectrotemporal modulation (STM) applied to octave-band noise were measured for normal-hearing and HI listeners as a function of temporal modulation rate (4–32 Hz), spectral ripple density [0.5–4 cycles/octave (c/o)] and carrier center frequency (500–4000 Hz). STM sensitivity was worse than normal for HI listeners only for a low-frequency carrier (1000 Hz) at low temporal modulation rates (4–12 Hz) and a spectral ripple density of 2 c/o, and for a high-frequency carrier (4000 Hz) at a high spectral ripple density (4 c/o). STM sensitivity for the 4-Hz, 4-c/o condition for a 4000-Hz carrier and for the 4-Hz, 2-c/o condition for a 1000-Hz carrier were correlated with speech-recognition performance in noise after partialling out the audiogram-based speech-intelligibility index. Poor speech-reception and STM-detection performance for HI listeners may be related to a combination of reduced frequency selectivity and a TFS-processing deficit limiting the ability to track spectral-peak movements. PMID:24993215

  8. Binaural Interaction Effects of 30-50 Hz Auditory Steady State Responses.

    PubMed

    Gransier, Robin; van Wieringen, Astrid; Wouters, Jan

    Auditory stimuli modulated by modulation frequencies within the 30 to 50 Hz region evoke auditory steady state responses (ASSRs) with high signal to noise ratios in adults, and can be used to determine the frequency-specific hearing thresholds of adults who are unable to give behavioral feedback reliably. To measure ASSRs as efficiently as possible a multiple stimulus paradigm can be used, stimulating both ears simultaneously. The response strength of 30 to 50Hz ASSRs is, however, affected when both ears are stimulated simultaneously. The aim of the present study is to gain insight in the measurement efficiency of 30 to 50 Hz ASSRs evoked with a 2-ear stimulation paradigm, by systematically investigating the binaural interaction effects of 30 to 50 Hz ASSRs in normal-hearing adults. ASSRs were obtained with a 64-channel EEG system in 23 normal-hearing adults. All participants participated in one diotic, multiple dichotic, and multiple monaural conditions. Stimuli consisted of a modulated one-octave noise band, centered at 1 kHz, and presented at 70 dB SPL. The diotic condition contained 40 Hz modulated stimuli presented to both ears. In the dichotic conditions, the modulation frequency of the left ear stimulus was kept constant at 40 Hz, while the stimulus at the right ear was either the unmodulated or modulated carrier. In case of the modulated carrier, the modulation frequency varied between 30 and 50 Hz in steps of 2 Hz across conditions. The monaural conditions consisted of all stimuli included in the diotic and dichotic conditions. Modulation frequencies ≥36 Hz resulted in prominent ASSRs in all participants for the monaural conditions. A significant enhancement effect was observed (average: ~3 dB) in the diotic condition, whereas a significant reduction effect was observed in the dichotic conditions. There was no distinct effect of the temporal characteristics of the stimuli on the amount of reduction. The attenuation was in 33% of the cases >3 dB for ASSRs evoked with modulation frequencies ≥40 Hz and 50% for ASSRs evoked with modulation frequencies ≤36 Hz. Binaural interaction effects as observed in the diotic condition are similar to the binaural interaction effects of middle latency responses as reported in the literature, suggesting that these responses share a same underlying mechanism. Our data also indicated that 30 to 50 Hz ASSRs are attenuated when presented dichotically and that this attenuation is independent of the stimulus characteristics as used in the present study. These findings are important as they give insight in how binaural interaction affects the measurement efficiency. The 2-ear stimulation paradigm of the present study was, for the most optimal modulation frequencies (i.e., ≥40 Hz), more efficient than a 1-ear sequential stimulation paradigm in 66% of the cases.

  9. A Fiber-Optic Interferometric Tri-Component Geophone for Ocean Floor Seismic Monitoring

    PubMed Central

    Chen, Jiandong; Chang, Tianying; Fu, Qunjian; Lang, Jinpeng; Gao, Wenzhi; Wang, Zhongmin; Yu, Miao; Zhang, Yanbo; Cui, Hong-Liang

    2016-01-01

    For the implementation of an all fiber observation network for submarine seismic monitoring, a tri-component geophone based on Michelson interferometry is proposed and tested. A compliant cylinder-based sensor head is analyzed with finite element method and tested. The operation frequency ranges from 2 Hz to 150 Hz for acceleration detection, employing a phase generated carrier demodulation scheme, with a responsivity above 50 dB re rad/g for the whole frequency range. The transverse suppression ratio is about 30 dB. The system noise at low frequency originated mainly from the 1/f fluctuation, with an average system noise level −123.55 dB re rad/Hz ranging from 0 Hz to 500 Hz. The minimum detectable acceleration is about 2 ng/Hz, and the dynamic range is above 116 dB. PMID:28036011

  10. Effect of pulmonary vein isolation on the left-to-right atrial dominant frequency gradient in human atrial fibrillation.

    PubMed

    Lazar, Sorin; Dixit, Sanjay; Callans, David J; Lin, David; Marchlinski, Francis E; Gerstenfeld, Edward P

    2006-08-01

    We previously demonstrated the existence of a left-to-right atrial dominant frequency gradient during paroxysmal but not persistent atrial fibrillation (AF) in humans. One possible mechanism of the left-to-right dominant frequency gradient involves the role of the pulmonary veins (PVs) in AF maintenance. The purpose of this study was to examine the effect of PV isolation on the dominant frequency gradient and outcome after PV isolation. Patients with either paroxysmal or persistent AF were studied. Recordings were made from catheters in the coronary sinus (CS), posterior right atrium (RA), and posterior left atrium (LA) during AF before and after PV isolation. Mean left-to-right dominant frequency gradient was measured before and after segmental PV isolation. Patients were followed for AF recurrence after PV isolation. Twenty-seven patients with paroxysmal (n = 15) or persistent (n = 12) AF were studied. In the paroxysmal group, baseline dominant frequency was greatest in the posterior LA with a significant left-to-right atrial dominant frequency gradient (posterior LA = 6.2 +/- 0.9 Hz, CS = 5.8 +/- 0.8 Hz, posterior RA = 5.4 +/- 0.9 Hz; P <.001). After PV isolation, there was no regional difference in dominant frequency (5.9 +/- 0.7 Hz vs 5.7 +/- 0.6 Hz vs 5.7 +/- 0.7 Hz, respectively; P = NS). In the persistent AF group, there was no overall difference in dominant frequency among sites before or after PV isolation (P = NS); however, patients with long-term freedom from AF after PV isolation had a higher left-to-right dominant frequency gradient compared with patients with recurrent AF (0.4 vs 0.1 Hz; P <.05). PV isolation results in a loss in the left-to-right dominant frequency gradient in patients with paroxysmal AF. This finding supports the critical role of PVs in the maintenance of ongoing paroxysmal AF. Patients with persistent AF and a baseline left-to-right dominant frequency gradient have a better success rate with PV isolation alone compared with patients without a dominant frequency gradient.

  11. Tuning of gravity-dependent and gravity-independent vertical angular VOR gain changes by frequency of adaptation

    PubMed Central

    2012-01-01

    The gain of the vertical angular vestibulo-ocular reflex (aVOR) was adaptively increased and decreased in a side-down head orientation for 4 h in two cynomolgus monkeys. Adaptation was performed at 0.25, 1, 2, or 4 Hz. The gravity-dependent and -independent gain changes were determined over a range of head orientations from left-side-down to right-side-down at frequencies from 0.25 to 10 Hz, before and after adaptation. Gain changes vs. frequency data were fit with a Gaussian to determine the frequency at which the peak gain change occurred, as well as the tuning width. The frequency at which the peak gravity-dependent gain change occurred was approximately equal to the frequency of adaptation, and the width increased monotonically with increases in the frequency of adaptation. The gravity-independent component was tuned to the adaptive frequency of 0.25 Hz but was uniformly distributed over all frequencies when the adaptation frequency was 1–4 Hz. The amplitude of the gravity-independent gain changes was larger after the aVOR gain decrease than after the gain increase across all tested frequencies. For the aVOR gain decrease, the phase lagged about 4° for frequencies below the adaptation frequency and led for frequencies above the adaptation frequency. For gain increases, the phase relationship as a function of frequency was inverted. This study demonstrates that the previously described dependence of aVOR gain adaptation on frequency is a property of the gravity-dependent component of the aVOR only. The gravity-independent component of the aVOR had a substantial tuning curve only at an adaptation frequency of 0.25 Hz. PMID:22402654

  12. Tuning of gravity-dependent and gravity-independent vertical angular VOR gain changes by frequency of adaptation.

    PubMed

    Yakushin, Sergei B

    2012-06-01

    The gain of the vertical angular vestibulo-ocular reflex (aVOR) was adaptively increased and decreased in a side-down head orientation for 4 h in two cynomolgus monkeys. Adaptation was performed at 0.25, 1, 2, or 4 Hz. The gravity-dependent and -independent gain changes were determined over a range of head orientations from left-side-down to right-side-down at frequencies from 0.25 to 10 Hz, before and after adaptation. Gain changes vs. frequency data were fit with a Gaussian to determine the frequency at which the peak gain change occurred, as well as the tuning width. The frequency at which the peak gravity-dependent gain change occurred was approximately equal to the frequency of adaptation, and the width increased monotonically with increases in the frequency of adaptation. The gravity-independent component was tuned to the adaptive frequency of 0.25 Hz but was uniformly distributed over all frequencies when the adaptation frequency was 1-4 Hz. The amplitude of the gravity-independent gain changes was larger after the aVOR gain decrease than after the gain increase across all tested frequencies. For the aVOR gain decrease, the phase lagged about 4° for frequencies below the adaptation frequency and led for frequencies above the adaptation frequency. For gain increases, the phase relationship as a function of frequency was inverted. This study demonstrates that the previously described dependence of aVOR gain adaptation on frequency is a property of the gravity-dependent component of the aVOR only. The gravity-independent component of the aVOR had a substantial tuning curve only at an adaptation frequency of 0.25 Hz.

  13. New sample cell configuration for wide-frequency dielectric spectroscopy: DC to radio frequencies.

    PubMed

    Nakanishi, Masahiro; Sasaki, Yasutaka; Nozaki, Ryusuke

    2010-12-01

    A new configuration for the sample cell to be used in broadband dielectric spectroscopy is presented. A coaxial structure with a parallel plate capacitor (outward parallel plate cell: OPPC) has made it possible to extend the frequency range significantly in comparison with the frequency range of the conventional configuration. In the proposed configuration, stray inductance is significantly decreased; consequently, the upper bound of the frequency range is improved by two orders of magnitude from the upper limit of conventional parallel plate capacitor (1 MHz). Furthermore, the value of capacitance is kept high by using a parallel plate configuration. Therefore, the precision of the capacitance measurement in the lower frequency range remains sufficiently high. Finally, OPPC can cover a wide frequency range (100 Hz-1 GHz) with an appropriate admittance measuring apparatus such as an impedance or network analyzer. The OPPC and the conventional dielectric cell are compared by examining the frequency dependence of the complex permittivity for several polar liquids and polymeric films.

  14. Underwater audiogram of the California sea lion by the conditioned vocalization technique1

    PubMed Central

    Schusterman, Ronald J.; Balliet, Richard F.; Nixon, James

    1972-01-01

    Conditioning techniques were developed demonstrating that pure tone frequencies under water can exert nearly perfect control over the underwater click vocalizations of the California sea lion (Zalophus californianus). Conditioned vocalizations proved to be a reliable way of obtaining underwater sound detection thresholds in Zalophus at 13 different frequencies, covering a frequency range of 250 to 64,000 Hz. The audiogram generated by these threshold measurements suggests that under water, the range of maximal sensitivity for Zalophus lies between one and 28 kHz with best sensitivity at 16 kHz. Between 28 and 36 kHz there is a loss in sensitivity of 60 dB/octave. However, with relatively intense acoustic signals (> 38 dB re 1 μb underwater), Zalophus will respond to frequencies at least as high as 192 kHz. These results are compared with the underwater hearing of other marine mammals. ImagesFig. 1. PMID:5033891

  15. Characteristics of magnetospheric radio noise spectra

    NASA Technical Reports Server (NTRS)

    Herman, J. R.

    1976-01-01

    Magnetospheric radio noise spectra (30 kHz to 10 MHz) taken by IMP-6 and RAE-2 exhibit time-varying characteristics which are related to spacecraft position and magnetospheric processes. In the mid-frequency range (100-1,000 kHz) intense noise peaks rise by a factor of 100 or more above background; 80% of the peak frequencies are within the band 125 kHz to 600 kHz, and the peak occurs most often (18% of the time) at 280 kHz. This intense mid-frequency noise has been detected at radial distances from 1.3 Re to 60 Re on all sides of the Earth during magnetically quiet as well as disturbed periods. Maximum occurrence of the mid-frequency noise is in the evening to midnight hours where splash-type energetic particle precipitation takes place. ""Magnetospheric lightning'' can be invoked to explain the spectral shape of the observed spectra.

  16. Infrasonic Signals from the 29 June 2012 Derecho

    NASA Astrophysics Data System (ADS)

    Winslow, N.; Howard, W. B.; Pulli, J. J.; Kofford, A. S.

    2012-12-01

    Common weather events such as pressure fronts, tornados, and hurricanes generate infrasonic signals (sub-audible acoustic signals with an oscillatory frequency below 20 Hz). These signals can provide a distal (>10km) analysis of weather events because: (1) the attenuation of an infrasonic signal with distance is less than that of a similar audible signal, and (2) the propagation velocities of typical weather events are much slower than the speed of sound. The 29 June, 2012 Derecho (a widespread, long-lived, rapidly moving linear band of storms extending more than 240 miles and including wind gusts in excess of 58 mph) that stretched from Chicago, IL to Washington, DC generated infrasonic signals in addition to causing over $100 million in damage to the power systems of Virginia, West Virginia, and Maryland alone. The infrasonic (and seismic) signals from this event were recorded on the NCPA micro barometers along the northeastern edge of the current configuration of the USArray. These instruments, which sample at 40 Hz, exhibit a flat frequency response from around 0.1 Hz to above 20 Hz and show a sensitivity of 1.57 x 104 Volts/Pascal at 0.8 Hz. An analysis of the recordings observed at multiple stations identified several infrasonic signatures from the Derecho. The signal's duration was approximately 40 minutes and exhibited a large peak pressure fluctuation. A characteristic ramp up occurred before the peak pressure fluctuation, and the majority of the infrasonic energy occurred below 1 Hz. These signatures are analyzed within the context of the Derecho as an infrasonic source, and the propagation of infrasound in the atmosphere.

  17. Brightness Induction and Suprathreshold Vision: Effects of Age and Visual Field

    PubMed Central

    McCourt, Mark E.; Leone, Lynnette M.; Blakeslee, Barbara

    2014-01-01

    A variety of visual capacities show significant age-related alterations. We assessed suprathreshold contrast and brightness perception across the lifespan in a large sample of healthy participants (N = 155; 142) ranging in age from 16–80 years. Experiment 1 used a quadrature-phase motion cancelation technique (Blakeslee & McCourt, 2008) to measure canceling contrast (in central vision) for induced gratings at two temporal frequencies (1 Hz and 4 Hz) at two test field heights (0.5° or 2° × 38.7°; 0.052 c/d). There was a significant age-related reduction in canceling contrast at 4 Hz, but not at 1 Hz. We find no age-related change in induction magnitude in the 1 Hz condition. We interpret the age-related decline in grating induction magnitude at 4 Hz to reflect a diminished capacity for inhibitory processing at higher temporal frequencies. In Experiment 2 participants adjusted the contrast of a matching grating (0.5° or 2° × 38.7°; 0.052 c/d) to equal that of both real (30% contrast, 0.052 c/d) and induced (McCourt, 1982) standard gratings (100% inducing grating contrast; 0.052 c/d). Matching gratings appeared in the upper visual field (UVF) and test gratings appeared in the lower visual field (LVF), and vice versa, at eccentricities of ±7.5°. Average induction magnitude was invariant with age for both test field heights. There was a significant age-related reduction in perceived contrast of stimuli in the LVF versus UVF for both real and induced gratings. PMID:25462024

  18. Broadband classification and statistics of echoes from aggregations of fish measured by long-range, mid-frequency sonar.

    PubMed

    Jones, Benjamin A; Stanton, Timothy K; Colosi, John A; Gauss, Roger C; Fialkowski, Joseph M; Michael Jech, J

    2017-06-01

    For horizontal-looking sonar systems operating at mid-frequencies (1-10 kHz), scattering by fish with resonant gas-filled swimbladders can dominate seafloor and surface reverberation at long-ranges (i.e., distances much greater than the water depth). This source of scattering, which can be difficult to distinguish from other sources of scattering in the water column or at the boundaries, can add spatio-temporal variability to an already complex acoustic record. Sparsely distributed, spatially compact fish aggregations were measured in the Gulf of Maine using a long-range broadband sonar with continuous spectral coverage from 1.5 to 5 kHz. Observed echoes, that are at least 15 decibels above background levels in the horizontal-looking sonar data, are classified spectrally by the resonance features as due to swimbladder-bearing fish. Contemporaneous multi-frequency echosounder measurements (18, 38, and 120 kHz) and net samples are used in conjunction with physics-based acoustic models to validate this approach. Furthermore, the fish aggregations are statistically characterized in the long-range data by highly non-Rayleigh distributions of the echo magnitudes. These distributions are accurately predicted by a computationally efficient, physics-based model. The model accounts for beam-pattern and waveguide effects as well as the scattering response of aggregations of fish.

  19. Application of a Hough search for continuous gravitational waves on data from the fifth LIGO science run

    NASA Astrophysics Data System (ADS)

    Aasi, J.; Abadie, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Accadia, T.; Acernese, F.; Adams, C.; Adams, T.; Adhikari, R. X.; Affeldt, C.; Agathos, M.; Aggarwal, N.; Aguiar, O. D.; Ajith, P.; Allen, B.; Allocca, A.; Amador Ceron, E.; Amariutei, D.; Anderson, R. A.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C.; Areeda, J.; Ast, S.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Austin, L.; Aylott, B. E.; Babak, S.; Baker, P. T.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barker, D.; Barnum, S. H.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barton, M. A.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J.; Bauchrowitz, J.; Bauer, Th S.; Bebronne, M.; Behnke, B.; Bejger, M.; Beker, M. G.; Bell, A. S.; Bell, C.; Belopolski, I.; Bergmann, G.; Berliner, J. M.; Bersanetti, D.; Bertolini, A.; Bessis, D.; Betzwieser, J.; Beyersdorf, P. T.; Bhadbhade, T.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Bitossi, M.; Bizouard, M. A.; Black, E.; Blackburn, J. K.; Blackburn, L.; Blair, D.; Blom, M.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogan, C.; Bond, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, S.; Bosi, L.; Bowers, J.; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brannen, C. A.; Brau, J. E.; Breyer, J.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Britzger, M.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brückner, F.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cadonati, L.; Cagnoli, G.; Calderón Bustillo, J.; Calloni, E.; Camp, J. B.; Campsie, P.; Cannon, K. C.; Canuel, B.; Cao, J.; Capano, C. D.; Carbognani, F.; Carbone, L.; Caride, S.; Castiglia, A.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Chen, X.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Chow, J.; Christensen, N.; Chu, Q.; Chua, S. S. Y.; Chung, S.; Ciani, G.; Clara, F.; Clark, D. E.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Colombini, M.; Constancio, M., Jr.; Conte, A.; Conte, R.; Cook, D.; Corbitt, T. R.; Cordier, M.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M. W.; Coulon, J.-P.; Countryman, S.; Couvares, P.; Coward, D. M.; Cowart, M.; Coyne, D. C.; Craig, K.; Creighton, J. D. E.; Creighton, T. D.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dahl, K.; Dal Canton, T.; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dattilo, V.; Daudert, B.; Daveloza, H.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; Dayanga, T.; Debreczeni, G.; Degallaix, J.; Deleeuw, E.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dereli, H.; Dergachev, V.; DeRosa, R. T.; De Rosa, R.; DeSalvo, R.; Dhurandhar, S.; Díaz, M.; Dietz, A.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Virgilio, A.; Dmitry, K.; Donovan, F.; Dooley, K. L.; Doravari, S.; Drago, M.; Drever, R. W. P.; Driggers, J. C.; Du, Z.; Dumas, J.-C.; Dwyer, S.; Eberle, T.; Edwards, M.; Effler, A.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; EndrHoczi, G.; Essick, R.; Etzel, T.; Evans, K.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W.; Favata, M.; Fazi, D.; Fehrmann, H.; Feldbaum, D.; Ferrante, I.; Ferrini, F.; Fidecaro, F.; Finn, L. S.; Fiori, I.; Fisher, R.; Flaminio, R.; Foley, E.; Foley, S.; Forsi, E.; Fotopoulos, N.; Fournier, J.-D.; Franco, S.; Frasca, S.; Frasconi, F.; Frede, M.; Frei, M.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fujimoto, M.-K.; Fulda, P.; Fyffe, M.; Gair, J.; Gammaitoni, L.; Garcia, J.; Garufi, F.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; Gergely, L.; Ghosh, S.; Giaime, J. A.; Giampanis, S.; Giardina, K. D.; Giazotto, A.; Gil-Casanova, S.; Gill, C.; Gleason, J.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gordon, N.; Gorodetsky, M. L.; Gossan, S.; Goßler, S.; Gouaty, R.; Graef, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Griffo, C.; Groot, P.; Grote, H.; Grover, K.; Grunewald, S.; Guidi, G. M.; Guido, C.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Hall, B.; Hall, E.; Hammer, D.; Hammond, G.; Hanke, M.; Hanks, J.; Hanna, C.; Hanson, J.; Harms, J.; Harry, G. M.; Harry, I. W.; Harstad, E. D.; Hartman, M. T.; Haughian, K.; Hayama, K.; Heefner, J.; Heidmann, A.; Heintze, M.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Holt, K.; Hong, T.; Hooper, S.; Horrom, T.; Hosken, D. J.; Hough, J.; Howell, E. J.; Hu, Y.; Hua, Z.; Huang, V.; Huerta, E. A.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh, M.; Huynh-Dinh, T.; Iafrate, J.; Ingram, D. R.; Inta, R.; Isogai, T.; Ivanov, A.; Iyer, B. R.; Izumi, K.; Jacobson, M.; James, E.; Jang, H.; Jang, Y. J.; Jaranowski, P.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; K, Haris; Kalmus, P.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Kasturi, R.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufman, K.; Kawabe, K.; Kawamura, S.; Kawazoe, F.; Kéfélian, F.; Keitel, D.; Kelley, D. B.; Kells, W.; Keppel, D. G.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, B. K.; Kim, C.; Kim, K.; Kim, N.; Kim, W.; Kim, Y.-M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Koehlenbeck, S.; Kokeyama, K.; Kondrashov, V.; Koranda, S.; Korth, W. Z.; Kowalska, I.; Kozak, D.; Kremin, A.; Kringel, V.; Krishnan, B.; Królak, A.; Kucharczyk, C.; Kudla, S.; Kuehn, G.; Kumar, A.; Kumar, P.; Kumar, R.; Kurdyumov, R.; Kwee, P.; Landry, M.; Lantz, B.; Larson, S.; Lasky, P. D.; Lawrie, C.; Leaci, P.; Lebigot, E. O.; Lee, C.-H.; Lee, H. K.; Lee, H. M.; Lee, J.; Lee, J.; Leonardi, M.; Leong, J. R.; Le Roux, A.; Leroy, N.; Letendre, N.; Levine, B.; Lewis, J. B.; Lhuillier, V.; Li, T. G. F.; Lin, A. C.; Littenberg, T. B.; Litvine, V.; Liu, F.; Liu, H.; Liu, Y.; Liu, Z.; Lloyd, D.; Lockerbie, N. A.; Lockett, V.; Lodhia, D.; Loew, K.; Logue, J.; Lombardi, A. L.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Luan, J.; Lubinski, M. J.; Lück, H.; Lundgren, A. P.; Macarthur, J.; Macdonald, E.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magana-Sandoval, F.; Mageswaran, M.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Manca, G. M.; Mandel, I.; Mandic, V.; Mangano, V.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Marque, J.; Martelli, F.; Martin, I. W.; Martin, R. M.; Martinelli, L.; Martynov, D.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Matichard, F.; Matone, L.; Matzner, R. A.; Mavalvala, N.; May, G.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McGuire, S. C.; McIntyre, G.; McIver, J.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Meier, T.; Melatos, A.; Mendell, G.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyer, M. S.; Miao, H.; Michel, C.; Mikhailov, E. E.; Milano, L.; Miller, J.; Minenkov, Y.; Mingarelli, C. M. F.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Mohan, M.; Mohapatra, S. R. P.; Mokler, F.; Moraru, D.; Moreno, G.; Morgado, N.; Mori, T.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nagy, M. F.; Nanda Kumar, D.; Nardecchia, I.; Nash, T.; Naticchioni, L.; Nayak, R.; Necula, V.; Nelemans, G.; Neri, I.; Neri, M.; Newton, G.; Nguyen, T.; Nishida, E.; Nishizawa, A.; Nitz, A.; Nocera, F.; Nolting, D.; Normandin, M. E.; Nuttall, L. K.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oppermann, P.; O'Reilly, B.; Ortega Larcher, W.; O'Shaughnessy, R.; Osthelder, C.; Ott, C. D.; Ottaway, D. J.; Ottens, R. S.; Ou, J.; Overmier, H.; Owen, B. J.; Padilla, C.; Pai, A.; Palomba, C.; Pan, Y.; Pankow, C.; Paoletti, F.; Paoletti, R.; Papa, M. A.; Paris, H.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Pedraza, M.; Peiris, P.; Penn, S.; Perreca, A.; Phelps, M.; Pichot, M.; Pickenpack, M.; Piergiovanni, F.; Pierro, V.; Pinard, L.; Pindor, B.; Pinto, I. M.; Pitkin, M.; Poeld, J.; Poggiani, R.; Poole, V.; Poux, C.; Predoi, V.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prix, R.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Quetschke, V.; Quintero, E.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Raja, S.; Rajalakshmi, G.; Rakhmanov, M.; Ramet, C.; Rapagnani, P.; Raymond, V.; Re, V.; Reed, C. M.; Reed, T.; Regimbau, T.; Reid, S.; Reitze, D. H.; Ricci, F.; Riesen, R.; Riles, K.; Robertson, N. A.; Robinet, F.; Rocchi, A.; Roddy, S.; Rodriguez, C.; Rodruck, M.; Roever, C.; Rolland, L.; Rollins, J. G.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Salemi, F.; Sammut, L.; Sancho de la Jordana, L.; Sandberg, V.; Sanders, J.; Sannibale, V.; Santiago-Prieto, I.; Saracco, E.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R.; Schilling, R.; Schnabel, R.; Schofield, R. M. S.; Schreiber, E.; Schuette, D.; Schulz, B.; Schutz, B. F.; Schwinberg, P.; Scott, J.; Scott, S. M.; Seifert, F.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D.; Shah, S.; Shahriar, M. S.; Shaltev, M.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siellez, K.; Siemens, X.; Sigg, D.; Simakov, D.; Singer, A.; Singer, L.; Sintes, A. M.; Skelton, G. R.; Slagmolen, B. J. J.; Slutsky, J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Soden, K.; Son, E. J.; Sorazu, B.; Souradeep, T.; Sperandio, L.; Staley, A.; Steinert, E.; Steinlechner, J.; Steinlechner, S.; Steplewski, S.; Stevens, D.; Stochino, A.; Stone, R.; Strain, K. A.; Straniero, N.; Strigin, S.; Stroeer, A. S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Susmithan, S.; Sutton, P. J.; Swinkels, B.; Szeifert, G.; Tacca, M.; Talukder, D.; Tang, L.; Tanner, D. B.; Tarabrin, S. P.; Taylor, R.; ter Braack, A. P. M.; Thirugnanasambandam, M. P.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, V.; Tokmakov, K. V.; Tomlinson, C.; Toncelli, A.; Tonelli, M.; Torre, O.; Torres, C. V.; Torrie, C. I.; Travasso, F.; Traylor, G.; Tse, M.; Ugolini, D.; Unnikrishnan, C. S.; Vahlbruch, H.; Vajente, G.; Vallisneri, M.; van den Brand, J. F. J.; Van Den Broeck, C.; van der Putten, S.; van der Sluys, M. V.; van Heijningen, J.; van Veggel, A. A.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Verma, S.; Vetrano, F.; Viceré, A.; Vincent-Finley, R.; Vinet, J.-Y.; Vitale, S.; Vlcek, B.; Vo, T.; Vocca, H.; Vorvick, C.; Vousden, W. D.; Vrinceanu, D.; Vyachanin, S. P.; Wade, A.; Wade, L.; Wade, M.; Waldman, S. J.; Walker, M.; Wallace, L.; Wan, Y.; Wang, J.; Wang, M.; Wang, X.; Wanner, A.; Ward, R. L.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; West, M.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; White, D. J.; Whiting, B. F.; Wibowo, S.; Wiesner, K.; Wilkinson, C.; Williams, L.; Williams, R.; Williams, T.; Willis, J. L.; Willke, B.; Wimmer, M.; Winkelmann, L.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Worden, J.; Yablon, J.; Yakushin, I.; Yamamoto, H.; Yancey, C. C.; Yang, H.; Yeaton-Massey, D.; Yoshida, S.; Yum, H.; Yvert, M.; Zadrożny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, F.; Zhang, L.; Zhao, C.; Zhu, H.; Zhu, X. J.; Zotov, N.; Zucker, M. E.; Zweizig, J.

    2014-04-01

    We report on an all-sky search for periodic gravitational waves in the frequency range 50-1000 Hz with the first derivative of frequency in the range -8.9 × 10-10 Hz s-1 to zero in two years of data collected during LIGO’s fifth science run. Our results employ a Hough transform technique, introducing a χ2 test and analysis of coincidences between the signal levels in years 1 and 2 of observations that offers a significant improvement in the product of strain sensitivity with compute cycles per data sample compared to previously published searches. Since our search yields no surviving candidates, we present results taking the form of frequency dependent, 95% confidence upper limits on the strain amplitude h0. The most stringent upper limit from year 1 is 1.0 × 10-24 in the 158.00-158.25 Hz band. In year 2, the most stringent upper limit is 8.9 × 10-25 in the 146.50-146.75 Hz band. This improved detection pipeline, which is computationally efficient by at least two orders of magnitude better than our flagship Einstein@Home search, will be important for ‘quick-look’ searches in the Advanced LIGO and Virgo detector era.

  20. Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

    NASA Astrophysics Data System (ADS)

    Castellví, Quim; Mercadal, Borja; Moll, Xavier; Fondevila, Dolors; Andaluz, Anna; Ivorra, Antoni

    2018-02-01

    Electroporation-based treatments typically consist of the application of high-voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. The present in vivo study explores the use of bursts of sinusoidal voltage in a frequency range from 50 kHz to 2 MHz, to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. A series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 µs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration, and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later post-processed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal to or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV cm-1 whereas that of dc pulses is about 0.5 kV cm-1.

  1. Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users.

    PubMed

    Anderson, Elizabeth S; Nelson, David A; Kreft, Heather; Nelson, Peggy B; Oxenham, Andrew J

    2011-07-01

    Spectral ripple discrimination thresholds were measured in 15 cochlear-implant users with broadband (350-5600 Hz) and octave-band noise stimuli. The results were compared with spatial tuning curve (STC) bandwidths previously obtained from the same subjects. Spatial tuning curve bandwidths did not correlate significantly with broadband spectral ripple discrimination thresholds but did correlate significantly with ripple discrimination thresholds when the rippled noise was confined to an octave-wide passband, centered on the STC's probe electrode frequency allocation. Ripple discrimination thresholds were also measured for octave-band stimuli in four contiguous octaves, with center frequencies from 500 Hz to 4000 Hz. Substantial variations in thresholds with center frequency were found in individuals, but no general trends of increasing or decreasing resolution from apex to base were observed in the pooled data. Neither ripple nor STC measures correlated consistently with speech measures in noise and quiet in the sample of subjects in this study. Overall, the results suggest that spectral ripple discrimination measures provide a reasonable measure of spectral resolution that correlates well with more direct, but more time-consuming, measures of spectral resolution, but that such measures do not always provide a clear and robust predictor of performance in speech perception tasks. © 2011 Acoustical Society of America

  2. Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users

    PubMed Central

    Anderson, Elizabeth S.; Nelson, David A.; Kreft, Heather; Nelson, Peggy B.; Oxenham, Andrew J.

    2011-01-01

    Spectral ripple discrimination thresholds were measured in 15 cochlear-implant users with broadband (350–5600 Hz) and octave-band noise stimuli. The results were compared with spatial tuning curve (STC) bandwidths previously obtained from the same subjects. Spatial tuning curve bandwidths did not correlate significantly with broadband spectral ripple discrimination thresholds but did correlate significantly with ripple discrimination thresholds when the rippled noise was confined to an octave-wide passband, centered on the STC’s probe electrode frequency allocation. Ripple discrimination thresholds were also measured for octave-band stimuli in four contiguous octaves, with center frequencies from 500 Hz to 4000 Hz. Substantial variations in thresholds with center frequency were found in individuals, but no general trends of increasing or decreasing resolution from apex to base were observed in the pooled data. Neither ripple nor STC measures correlated consistently with speech measures in noise and quiet in the sample of subjects in this study. Overall, the results suggest that spectral ripple discrimination measures provide a reasonable measure of spectral resolution that correlates well with more direct, but more time-consuming, measures of spectral resolution, but that such measures do not always provide a clear and robust predictor of performance in speech perception tasks. PMID:21786905

  3. Acoustic detection of pneumothorax

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Royston, Thomas J.; Balk, Robert A.; Sandler, Richard H.

    2003-04-01

    This study aims at investigating the feasibility of using low-frequency (<2000 Hz) acoustic methods for medical diagnosis. Several candidate methods of pneumothorax detection were tested in dogs. In the first approach, broadband acoustic signals were introduced into the trachea during end-expiration and transmitted waves were measured at the chest surface. Pneumothorax was found to consistently decrease pulmonary acoustic transmission in the 200-1200-Hz frequency band, while less change was observed at lower frequencies (p<0.0001). The ratio of acoustic energy between low (<220 Hz) and mid (550-770 Hz) frequency bands was significantly different in the control (healthy) and pneumothorax states (p<0.0001). The second approach measured breath sounds in the absence of an external acoustic input. Pneumothorax was found to be associated with a preferential reduction of sound amplitude in the 200- to 700-Hz range, and a decrease of sound amplitude variation (in the 300 to 600-Hz band) during the respiration cycle (p<0.01 for each). Finally, chest percussion was implemented. Pneumothorax changed the frequency and decay rate of percussive sounds. These results imply that certain medical conditions may be reliably detected using appropriate acoustic measurements and analysis. [Work supported by NIH/NHLBI #R44HL61108.

  4. Spectral Separation of the Turbofan Engine Coherent Combustion Noise Component

    NASA Technical Reports Server (NTRS)

    Miles, Jeffrey Hilton

    2008-01-01

    The core noise components of a dual spool turbofan engine (Honeywell TECH977) were separated by the use of a coherence function. A source location technique based on adjusting the time delay between the combustor pressure sensor signal and the far-field microphone signal to maximize the coherence and remove as much variation of the phase angle with frequency as possible was used. While adjusting the time delay to maximize the coherence and minimize the cross spectrum phase angle variation with frequency, the discovery was made that for the 130 microphone a 90.027 ms time shift worked best for the frequency band from 0 to 200 Hz while a 86.975 ms time shift worked best for the frequency band from 200 to 400 Hz. Since the 0 to 200 Hz band signal took more time to travel the same distance, it is slower than the 200 to 400 Hz band signal. This suggests the 0 to 200 Hz coherent cross spectral density band is partly due to indirect combustion noise attributed to hot spots interacting with the turbine. The signal in the 200 to 400 Hz frequency band is attributed mostly to direct combustion noise.

  5. Specializations for aerial hawking in the echolocation system of Molossus molossus (Molossidae, Chiroptera).

    PubMed

    Mora, E C; Macías, S; Vater, M; Coro, F; Kössl, M

    2004-07-01

    While searching for prey, Molossus molossus broadcasts narrow-band calls of 11.42 ms organized in pairs of pulses that alternate in frequency. The first signal of the pair is at 34.5 kHz, the second at 39.6 kHz. Pairs of calls with changing frequencies were only emitted when the interpulse intervals were below 200 ms. Maximum duty cycles during search phase are close to 20%. Frequency alternation of search calls is interpreted as a mechanism for increasing duty cycle and thus the temporal continuity of scanning, as well as increasing the detection range. A neurophysiological correlate for the processing of search calls was found in the inferior colliculus. 64% of neurons respond to frequencies in the 30- to 40-kHz range and only in this frequency range were closed tuning curves found for levels below 40 dB SPL. In addition, 15% of the neurons have double-tuned frequency-threshold curves with best thresholds at 34 and 39 kHz. Differing from observations in other bats, approach calls of M. molossus are longer and of higher frequencies than search calls. Close to the roost, the call frequency is increased to 45.0-49.8 kHz and, in addition, extremely broadband signals are emitted. This demonstrates high plasticity of call design.

  6. Integration of auditory and vibrotactile stimuli: Effects of frequency

    PubMed Central

    Wilson, E. Courtenay; Reed, Charlotte M.; Braida, Louis D.

    2010-01-01

    Perceptual integration of vibrotactile and auditory sinusoidal tone pulses was studied in detection experiments as a function of stimulation frequency. Vibrotactile stimuli were delivered through a single channel vibrator to the left middle fingertip. Auditory stimuli were presented diotically through headphones in a background of 50 dB sound pressure level broadband noise. Detection performance for combined auditory-tactile presentations was measured using stimulus levels that yielded 63% to 77% correct unimodal performance. In Experiment 1, the vibrotactile stimulus was 250 Hz and the auditory stimulus varied between 125 and 2000 Hz. In Experiment 2, the auditory stimulus was 250 Hz and the tactile stimulus varied between 50 and 400 Hz. In Experiment 3, the auditory and tactile stimuli were always equal in frequency and ranged from 50 to 400 Hz. The highest rates of detection for the combined-modality stimulus were obtained when stimulating frequencies in the two modalities were equal or closely spaced (and within the Pacinian range). Combined-modality detection for closely spaced frequencies was generally consistent with an algebraic sum model of perceptual integration; wider-frequency spacings were generally better fit by a Pythagorean sum model. Thus, perceptual integration of auditory and tactile stimuli at near-threshold levels appears to depend both on absolute frequency and relative frequency of stimulation within each modality. PMID:21117754

  7. A Comprehensive Analysis of the Correlations between Resting-State Oscillations in Multiple-Frequency Bands and Big Five Traits

    PubMed Central

    Ikeda, Shigeyuki; Takeuchi, Hikaru; Taki, Yasuyuki; Nouchi, Rui; Yokoyama, Ryoichi; Kotozaki, Yuka; Nakagawa, Seishu; Sekiguchi, Atsushi; Iizuka, Kunio; Yamamoto, Yuki; Hanawa, Sugiko; Araki, Tsuyoshi; Miyauchi, Carlos Makoto; Sakaki, Kohei; Nozawa, Takayuki; Yokota, Susumu; Magistro, Daniele; Kawashima, Ryuta

    2017-01-01

    Recently, the association between human personality traits and resting-state brain activity has gained interest in neuroimaging studies. However, it remains unclear if Big Five personality traits are represented in frequency bands (~0.25 Hz) of resting-state functional magnetic resonance imaging (fMRI) activity. Based on earlier neurophysiological studies, we investigated the correlation between the five personality traits assessed by the NEO Five-Factor Inventory (NEO-FFI), and the fractional amplitude of low-frequency fluctuation (fALFF) at four distinct frequency bands (slow-5 (0.01–0.027 Hz), slow-4 (0.027–0.073 Hz), slow-3 (0.073–0.198 Hz) and slow-2 (0.198–0.25 Hz)). We enrolled 835 young subjects and calculated the correlations of resting-state fMRI signals using a multiple regression analysis. We found a significant and consistent correlation between fALFF and the personality trait of extraversion at all frequency bands. Furthermore, significant correlations were detected in distinct brain regions for each frequency band. This finding supports the frequency-specific spatial representations of personality traits as previously suggested. In conclusion, our data highlight an association between human personality traits and fALFF at four distinct frequency bands. PMID:28680397

  8. A Comprehensive Analysis of the Correlations between Resting-State Oscillations in Multiple-Frequency Bands and Big Five Traits.

    PubMed

    Ikeda, Shigeyuki; Takeuchi, Hikaru; Taki, Yasuyuki; Nouchi, Rui; Yokoyama, Ryoichi; Kotozaki, Yuka; Nakagawa, Seishu; Sekiguchi, Atsushi; Iizuka, Kunio; Yamamoto, Yuki; Hanawa, Sugiko; Araki, Tsuyoshi; Miyauchi, Carlos Makoto; Sakaki, Kohei; Nozawa, Takayuki; Yokota, Susumu; Magistro, Daniele; Kawashima, Ryuta

    2017-01-01

    Recently, the association between human personality traits and resting-state brain activity has gained interest in neuroimaging studies. However, it remains unclear if Big Five personality traits are represented in frequency bands (~0.25 Hz) of resting-state functional magnetic resonance imaging (fMRI) activity. Based on earlier neurophysiological studies, we investigated the correlation between the five personality traits assessed by the NEO Five-Factor Inventory (NEO-FFI), and the fractional amplitude of low-frequency fluctuation (fALFF) at four distinct frequency bands (slow-5 (0.01-0.027 Hz), slow-4 (0.027-0.073 Hz), slow-3 (0.073-0.198 Hz) and slow-2 (0.198-0.25 Hz)). We enrolled 835 young subjects and calculated the correlations of resting-state fMRI signals using a multiple regression analysis. We found a significant and consistent correlation between fALFF and the personality trait of extraversion at all frequency bands. Furthermore, significant correlations were detected in distinct brain regions for each frequency band. This finding supports the frequency-specific spatial representations of personality traits as previously suggested. In conclusion, our data highlight an association between human personality traits and fALFF at four distinct frequency bands.

  9. Development of Multi-Degree-Of-Freedom Piezoelectric Energy Harvester Using Interdigital Shaped Cantilevers.

    PubMed

    Cho, Hyunok; Park, Jongcheol; Park, Jae Yeong

    2016-05-01

    A piezoelectric vibration energy harvester with interdigital shaped cantilever was developed by using silicon bulk micromachining technology. The proposed energy harvester was designed to obtain multi degree-of-freedom (m-DOF). Most of the piezoelectric vibration energy harvesters are comprised of mass-loaded cantilever beams having several resonant frequencies. The second resonant frequency of such a device has lower amplitude compared to its first resonant frequency (fundamental frequency). Therefore, the interdigital shaped cantilever has been proposed for multiple fundamental resonant frequencies. The fabricated piezoelectric vibration energy harvester is composed of main cantilever (MC), sub-main cantilever (SMC), and secondary cantilevers (SC). MC surrounds SMC and SC which have same dimension of 5600 x 800 x 10 μm3. The fabricated piezoelectric energy harvester can generate 51.4 mV(p-p) and 11 mV(p-p) of output voltages at 24.2 Hz and 33 Hz of its resonant frequencies by MC. Moreover, it can generate 8 mV(p-p) and 6.6 mV(p-p) of output voltages at 24.2 Hz and 33.2 Hz of its resonant frequencies by SMC; and 364 mV(p-p) of output voltage at 33.6 Hz of its resonant frequency by SC.

  10. Killer whale (Orcinus orca) hearing: auditory brainstem response and behavioral audiograms.

    PubMed

    Szymanski, M D; Bain, D E; Kiehl, K; Pennington, S; Wong, S; Henry, K R

    1999-08-01

    Killer whale (Orcinus orca) audiograms were measured using behavioral responses and auditory evoked potentials (AEPs) from two trained adult females. The mean auditory brainstem response (ABR) audiogram to tones between 1 and 100 kHz was 12 dB (re 1 mu Pa) less sensitive than behavioral audiograms from the same individuals (+/- 8 dB). The ABR and behavioral audiogram curves had shapes that were generally consistent and had the best threshold agreement (5 dB) in the most sensitive range 18-42 kHz, and the least (22 dB) at higher frequencies 60-100 kHz. The most sensitive frequency in the mean Orcinus audiogram was 20 kHz (36 dB), a frequency lower than many other odontocetes, but one that matches peak spectral energy reported for wild killer whale echolocation clicks. A previously reported audiogram of a male Orcinus had greatest sensitivity in this range (15 kHz, approximately 35 dB). Both whales reliably responded to 100-kHz tones (95 dB), and one whale to a 120-kHz tone, a variation from an earlier reported high-frequency limit of 32 kHz for a male Orcinus. Despite smaller amplitude ABRs than smaller delphinids, the results demonstrated that ABR audiometry can provide a useful suprathreshold estimate of hearing range in toothed whales.

  11. Analysis of Rayleigh-Lamb Modes in Soft-solids with Application to Surface Wave Elastography

    NASA Astrophysics Data System (ADS)

    Benech, Nicolás; Grinspan, Gustavo; Aguiar, Sofía; Brum, Javier; Negreira, Carlos; tanter, Mickäel; Gennisson, Jean-Luc

    The goal of Surface Wave Elastography (SE) techniques is to estimate the shear elasticity of the sample by measuring the surface wave speed. In SE the thickness of the sample is often assumed to be infinite, in this way, the surface wave speed is directly linked to the sample's shear elasticity. However for many applications this assumption is not true. In this work, we study experimentally the Rayleigh-Lamb modes in soft solids of finite thickness to explore the optimal conditions for SWE. Experiments were carried out in three tissue mimicking phantoms of different thicknesses (10 mm, 20 mm and 60 mm) and same shear elasticity. The surface waves were generated at the surface of the phantom using piston attached to a mechanical vibrator. The central frequency of the excitation was varied between 60 Hz to 160 Hz. One component of the displacement field generated by the piston was measured at the surface and in the bulk of the sample trough a standard speckle tracking technique using a 256 element, 7.5 MHz central frequency linear array and an ultrasound ultrafast electronics. Finally, by measuring the phase velocity at each excitation frequency, velocity dispersion curves were obtained for each phantom. The results show that instead of a Rayleigh wave, zero order symmetric (S0) and antisymmetric (A0) Lamb modes are excited with this type of source. Moreover, in this study we show that due to the near field effects of the source, which are appreciable only in soft solids at low frequencies, both Lamb modes are separable in time and space. We show that while the Ao mode dominates close the source, the S0 mode dominates far away.

  12. Probing matrix and tumor mechanics with in situ calibrated optical trap based active microrheology

    NASA Astrophysics Data System (ADS)

    Staunton, Jack Rory; Vieira, Wilfred; Tanner, Kandice; Tissue Morphodynamics Unit Team

    Aberrant extracellular matrix deposition and vascularization, concomitant with proliferation and phenotypic changes undergone by cancer cells, alter mechanical properties in the tumor microenvironment during cancer progression. Tumor mechanics conversely influence progression, and the identification of physical biomarkers promise improved diagnostic and prognostic power. Optical trap based active microrheology enables measurement of forces up to 0.5 mm within a sample, allowing interrogation of in vitro biomaterials, ex vivo tissue sections, and small organisms in vivo. We fabricated collagen I hydrogels exhibiting distinct structural properties by tuning polymerization temperature Tp, and measured their shear storage and loss moduli at frequencies 1-15k Hz at multiple amplitudes. Lower Tp gels, with larger pore size but thicker, longer fibers, were stiffer than higher Tp gels; decreasing strain increased loss moduli and decreased storage moduli at low frequencies. We subcutanously injected probes with metastatic murine melanoma cells into mice. The excised tumors displayed storage and loss moduli 40 Pa and 10 Pa at 1 Hz, increasing to 500 Pa and 1 kPa at 15 kHz, respectively.

  13. New clinical insights for transiently evoked otoacoustic emission protocols.

    PubMed

    Hatzopoulos, Stavros; Grzanka, Antoni; Martini, Alessandro; Konopka, Wieslaw

    2009-08-01

    The objective of the study was to optimize the area of a time-frequency analysis and then investigate any stable patterns in the time-frequency structure of otoacoustic emissions in a population of 152 healthy adults sampled over one year. TEOAE recordings were collected from 302 ears in subjects presenting normal hearing and normal impedance values. The responses were analyzed by the Wigner-Ville distribution (WVD). The TF region of analysis was optimized by examining the energy content of various rectangular and triangular TF regions. The TEOAE components from the initial and recordings 12 months later were compared in the optimized TF region. The best region for TF analysis was identified with base point 1 at 2.24 ms and 2466 Hz, base point 2 at 6.72 ms and 2466 Hz, and the top point at 2.24 ms and 5250 Hz. Correlation indices from the TF optimized region were higher, and were statistically significant, than the traditional indices in the selected time window. An analysis of the TF data within a 12-month period indicated a 85% TEOAE component similarity in 90% of the tested subjects.

  14. Whey acerola-flavoured drink submitted Ohmic Heating: Bioactive compounds, antioxidant capacity, thermal behavior, water mobility, fatty acid profile and volatile compounds.

    PubMed

    Cappato, Leandro P; Ferreira, Marcus Vinicius S; Moraes, Jeremias; Pires, Roberto P S; Rocha, Ramon S; Silva, Ramon; Neto, Roberto P C; Tavares, Maria Inês B; Freitas, Mônica Q; Rodrigues, Flavio N; Calado, Veronica M A; Raices, Renata S L; Silva, Marcia C; Cruz, Adriano G

    2018-10-15

    Whey acerola-flavoured drink was subjected to Ohmic Heating (OH) under different operational conditions (45, 60, 80 V at 60 Hz and 10, 100, 1000 Hz with 25 V, 65 °C/30 min) and conventional pasteurization (65 °C/30 min). Bioactive compounds (total phenolics, DPPH, FRAP, ACE levels), fatty acid profile, volatile compounds (CG-MS), thermal behaviors (DSC) and water mobility (TD-NMR) were performed. Reduction of frequency (1000-10 Hz) resulted in a lower bioactive compounds and antioxidant capacity of the samples, except for the DPPH values. Concerning the thermal behaviors, fatty acids profile and volatile compounds, different findings were observed as a function of the parameters used (voltage and frequency). In respect of TD-NMR parameters, OH led to a slightly reduction of the relaxation time when compared to the conventional treatment, suggesting more viscous beverages. Overall, OH may be interesting option to whey acerola-flavoured drink processing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Long-term measurements of acoustic background noise in very deep sea

    NASA Astrophysics Data System (ADS)

    Riccobene, G.; NEMO Collaboration

    2009-06-01

    The NEMO (NEutrino Mediterranean Observatory) Collaboration installed, 25 km E offshore the port of Catania (Sicily) at 2000 m depth, an underwater laboratory to perform long-term tests of prototypes and new technologies for an underwater high energy neutrino km-scale detector in the Mediterranean Sea. In this framework the Collaboration deployed and successfully operated for about two years, starting from January 2005, an experimental apparatus for on-line monitoring of deep-sea noise. The station was equipped with four hydrophones and it is operational in the range 30 Hz-43 kHz. This interval of frequencies matches the range suitable for the proposed acoustic detection technique of high energy neutrinos. Hydrophone signals were digitized underwater at 96 kHz sampling frequency and 24 bits resolution. The stored data library, consisting of more than 2000 h of recordings, is a unique tool to model underwater acoustic noise at large depth, to characterize its variations as a function of environmental parameters, biological sources and human activities (ship traffic, etc.), and to determine the presence of cetaceans in the area.

  16. Ongoing compound field potentials from octopus brain are labile and vertebrate-like.

    PubMed

    Bullock, T H

    1984-05-01

    Ongoing electrical activity was recorded from the brain of the virtually intact, semirestrained, unanesthetized octopus by semimicroelectrodes thrust through the cartilage into the optic, vertical or basal lobe. With flexible lead-in wires such electrodes were carried by and moved with the head without causing movement artifacts. Controls suggest that the activity reported comes from the brain; it is reversibly flattened by doses of urethane that do not embarrass respiration. Muscle potentials are only troublesome on occasion. Seen through a wideband filter, neuronal spikes are usually small or below noise level under these conditions; slow waves (1-70 Hz) dominate, with a maximum less than 25 Hz, usually less than 10 Hz and no consistent sharp peaks. The fall in power above ca. 25 Hz is usually slower than in the typical vertebrate EEG but the average power spectrum is much more like those of vertebrate brains than of cerebral ganglia of other invertebrates (insect, crustacean, gastropod). Variance among sample epochs is large, e.g. short spells may have relatively much more low frequency (less than 25 Hz) or more 'hashy' high frequency (greater than 50 Hz) energy; there may be runs of spikes. Fluctuation in the composition of ongoing activity is graphically shown by writing out in parallel the outputs of several narrow band (one octave) filters; this shows irregular low frequency waxing and waning of the amplitude in each band. The envelopes were computed and their peak power is around 1 Hz or lower; the waxing and waning in the several bands is sometimes strongly correlated, especially when the envelope amplitude is large and slow. Optic lobe activity tends usually to be faster, with more small spikey hash than in the vertical lobe. The described electrical activity of the brain is strikingly episodic; it is recorded during seconds or minutes separated by long intervals of nearly electrical silence (10-40 dB lower power; the difference larger at frequencies greater than 20 Hz). Active and quiet periods are usually not correlated with differences in visible behavior. Under my conditions the animal is usually not moving except for quiet ventilation and occasional local writhing of an arm. Potentials evoked by single flashes of light (0.2-1/sec) are conspicuous in the optic but not in the vertical lobe. They form a sequence of large, slow waves; the first peak may be at about 40 msec, others up to at least 400 msec.(ABSTRACT TRUNCATED AT 400 WORDS)

  17. Wide Temperature Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.

    1999-01-01

    100 kHz core loss and magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, at B(sub peak) = 0.1 T and 50 C only. A linear permeability model is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials arc reviewed. This linear modeling shows that, due to their high permeabilities, these cores must he gapped in order to make up high Q or high current inductors. However, they should serve well, as is, for high frequency, anti ratcheting transformer applications.

  18. Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

    NASA Astrophysics Data System (ADS)

    Farfurnik, D.; Jarmola, A.; Budker, D.; Bar-Gill, N.

    2018-01-01

    Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12C sample, we find that the Carr-Purcell-Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (> 500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (˜10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

  19. Large-scale cortical correlation structure of spontaneous oscillatory activity

    PubMed Central

    Hipp, Joerg F.; Hawellek, David J.; Corbetta, Maurizio; Siegel, Markus; Engel, Andreas K.

    2013-01-01

    Little is known about the brain-wide correlation of electrophysiological signals. Here we show that spontaneous oscillatory neuronal activity exhibits frequency-specific spatial correlation structure in the human brain. We developed an analysis approach that discounts spurious correlation of signal power caused by the limited spatial resolution of electrophysiological measures. We applied this approach to source estimates of spontaneous neuronal activity reconstructed from magnetoencephalography (MEG). Overall, correlation of power across cortical regions was strongest in the alpha to beta frequency range (8–32 Hz) and correlation patterns depended on the underlying oscillation frequency. Global hubs resided in the medial temporal lobe in the theta frequency range (4–6 Hz), in lateral parietal areas in the alpha to beta frequency range (8–23 Hz), and in sensorimotor areas for higher frequencies (32–45 Hz). Our data suggest that interactions in various large-scale cortical networks may be reflected in frequency specific power-envelope correlations. PMID:22561454

  20. Detection and evaluation of embedded mild steel can material into 18 Cr-oxide dispersion strengthened steel tubes by magnetic Barkhausen emission

    NASA Astrophysics Data System (ADS)

    Kishore, G. V. K.; Kumar, Anish; Rajkumar, K. V.; Purnachandra Rao, B.; Pramanik, Debabrata; Kapoor, Komal; Jha, Sanjay Kumar

    2017-12-01

    The paper presents a new methodology for detection and evaluation of mild steel (MS) can material embedded into oxide dispersion strengthened (ODS) steel tubes by magnetic Barkhausen emission (MBE) technique. The high frequency MBE measurements (125 Hz sweep frequency and 70-200 kHz analyzing frequency) are found to be very sensitive for detection of presence of MS on the surface of the ODS steel tube. However, due to a shallow depth of information from the high frequency MBE measurements, it cannot be used for evaluation of the thickness of the embedded MS. The low frequency MBE measurements (0.5 Hz sweep frequency and 2-20 kHz analyzing frequency) indicate presence of two MBE RMS voltage peaks corresponding to the MS and the ODS steel. The ratio of the two peaks changes with the thickness of the MS and hence, can be used for measurement of the thickness of the MS layer.

  1. Hearing at low and infrasonic frequencies.

    PubMed

    Møller, H; Pedersen, C S

    2004-01-01

    The human perception of sound at frequencies below 200 Hz is reviewed. Knowledge about our perception of this frequency range is important, since much of the sound we are exposed to in our everyday environment contains significant energy in this range. Sound at 20-200 Hz is called low-frequency sound, while for sound below 20 Hz the term infrasound is used. The hearing becomes gradually less sensitive for decreasing frequency, but despite the general understanding that infrasound is inaudible, humans can perceive infrasound, if the level is sufficiently high. The ear is the primary organ for sensing infrasound, but at levels somewhat above the hearing threshold it is possible to feel vibrations in various parts of the body. The threshold of hearing is standardized for frequencies down to 20 Hz, but there is a reasonably good agreement between investigations below this frequency. It is not only the sensitivity but also the perceived character of a sound that changes with decreasing frequency. Pure tones become gradually less continuous, the tonal sensation ceases around 20 Hz, and below 10 Hz it is possible to perceive the single cycles of the sound. A sensation of pressure at the eardrums also occurs. The dynamic range of the auditory system decreases with decreasing frequency. This compression can be seen in the equal-loudness-level contours, and it implies that a slight increase in level can change the perceived loudness from barely audible to loud. Combined with the natural spread in thresholds, it may have the effect that a sound, which is inaudible to some people, may be loud to others. Some investigations give evidence of persons with an extraordinary sensitivity in the low and infrasonic frequency range, but further research is needed in order to confirm and explain this phenomenon.

  2. Chirp-evoked potentials in the awake and anesthetized rat. A procedure to assess changes in cortical oscillatory activity.

    PubMed

    Pérez-Alcázar, M; Nicolás, M J; Valencia, M; Alegre, M; Iriarte, J; Artieda, J

    2008-03-01

    Steady-state potentials are oscillatory responses generated by rhythmic stimulation of a sensory pathway. The frequency of the response, which follows the frequency of stimulation and potentially indicates the preferential working frequency of the auditory neural network, is maximal at a stimulus rate of 40 Hz for auditory stimuli in humans, but may be different in other species. Our aim was to explore the responses to different frequencies in the rat. The stimulus was a tone modulated in amplitude by a sinusoid with linearly-increasing frequency from 1 to 250 Hz ("chirp"). Time-frequency transforms were used for response analysis in 12 animals, awake and under ketamine/xylazine anesthesia. We studied whether the responses were due to increases in amplitude or to phase-locking phenomena, using single-sweep time-frequency transforms and inter-trial phase analysis. A progressive decrease in the amplitude of the response was observed from the maximal values (around 15 Hz) up to the limit of the test (250 Hz). The high-frequency component was mainly due to phase-locking phenomena with a smaller amplitude contribution. Under anesthesia, the amplitude and phase-locking of lower frequencies (under 100 Hz) decreased, while the phase-locking over 200 Hz increased. In conclusion, amplitude-modulation following responses differ between humans and rats in response range and frequency of maximal amplitude. Anesthesia with ketamine/xylazine modifies differentially the amplitude and the phase-locking of the responses. These findings should be taken into account when assessing the changes in cortical oscillatory activity related to different drugs, in healthy rodents and in animal models of neurodegenerative diseases.

  3. Effect of input perturbation on the performance and wake dynamics of aquatic propulsion in heaving flexible foils

    NASA Astrophysics Data System (ADS)

    Lehn, Andrea M.; Thornycroft, Patrick J. M.; Lauder, George V.; Leftwich, Megan C.

    2017-02-01

    In this paper we consider the effects of adding high-frequency, low-amplitude perturbations to a smooth sinusoidal base input signal for a heaving panel in a closed loop flow tank. Specifically, 0.1 cm amplitude sinusoidal perturbation waves with frequency fp ranging from 0.5 to 13.0 Hz are added to 1 cm heave sinusoids with base frequencies, fb, ranging from 0.5 to 3.0 Hz. Two thin foils with different flexural stiffness are heaved with the combined input signals in addition to both the high-heave and low-heave signals independently. In all cases, the foils are heaved in a recirculating water channel with an incoming velocity of Vx=10 cm/s and a Reynolds number based on the chord length of Re=17 300 . Results demonstrate that perturbations increase the net axial force, in the streamwise direction, in most cases tested (with the exception of some poor performing flexible foil cases). Most significantly, for a base frequency of 1 Hz, perturbations at 9 Hz result in a 780.7% increase in net streamwise force production. Generally, the higher the perturbation frequency, fp the more axial force generated. However, for the stiffer foil, a clear peak in net force exists at fp=9 Hz , regardless of the base frequency. For the stiffer foil, swimming efficiency at a 1 Hz flapping frequency is increased dramatically with the addition of a perturbation, with reduced efficiency increases at higher flapping frequencies. Likewise, for the flexible foil, swimming efficiency gains are greatest at the lower flapping frequencies. Perturbations alter the wake structure by increasing the vorticity magnitude and increasing the vortex shedding frequency; i.e., more, stronger vortices are produced in each flapping cycle.

  4. The effect of 30 Hz vs. 50 Hz passive vibration and duration of vibration on skin blood flow in the arm.

    PubMed

    Maloney-Hinds, Colleen; Petrofsky, Jerrold Scott; Zimmerman, Grenith

    2008-03-01

    Recently, researchers have demonstrated that Whole Body Vibration (WBV) results in significant increases in skin blood flow (SBF). No study has determined if a specific frequency or a specific duration is better at optimizing SBF. Two studies were conducted to determine, 1) if there is a difference in SBF due to passive vibration of the forearm at 30 Hz vs. 50 Hz, 2) if one frequency is superior, and 3) if there is an optimal duration. In the first study, 18 subjects (mean age 20.3+/-2.9 years) were randomly placed into a 30 Hz or 50 Hz vibration group, and in the second, seven subjects (mean age 23.3+/-3.8 years) participated in both 30 and 50 Hz vibration. Each subject's arm was passively vibrated for 10 minutes. SBF was examined during vibration and for 15 minutes of recovery. Both frequencies produced significant increases in SBF (p<0.05) within the first four minutes of vibration. Peak SBFs were obtained by the fifth minute. SBF remained high for minutes 4 through 10 of vibration in the second study. In the first study, SBF remained high for minutes 4 through 9. During recovery, 30 Hz vibration produced SBFs below baseline values while 50 Hz SBFs remained above baseline. Statistically one frequency was not superior to the other. Five minutes of 30 Hz or 50 Hz vibration produced significant increases in SBF. Clinically, 50 Hz has additional benefits because SBF increased more rapidly and did not result in vasoconstriction during the recovery period. Future studies should be done to determine if these increases in SBF could be of benefit to populations with low circulation such as those with diabetes.

  5. Frequency-dependent ultrasound-induced transformation in E. coli.

    PubMed

    Deeks, Jeremy; Windmill, James; Agbeze-Onuma, Maduka; Kalin, Robert M; Argondizza, Peter; Knapp, Charles W

    2014-12-01

    Ultrasound-enhanced gene transfer (UEGT) is continuing to gain interest across many disciplines; however, very few studies investigate UEGT efficiency across a range of frequencies. Using a variable frequency generator, UEGT was tested in E. coli at six ultrasonic frequencies. Results indicate frequency can significantly influence UEGT efficiency positively and negatively. A frequency of 61 kHz improved UEGT efficiency by ~70 % higher, but 99 kHz impeded UEGT to an extent worse than no ultrasound exposure. The other four frequencies (26, 133, 174, and 190 kHz) enhanced transformation compared to no ultrasound, but efficiencies did not vary. The influence of frequency on UEGT efficiency was observed across a range of operating frequencies. It is plausible that frequency-dependent dynamics of mechanical and chemical energies released during cavitational-bubble collapse (CBC) are responsible for observed UEGT efficiencies.

  6. The Effects of Microstructure on Shear Properties of Shallow Marine Sediments

    DTIC Science & Technology

    2007-01-01

    frequency and voltage were set at 75 kHz and 5 V p - p for P -wave; 500 Hz and 10 V p - p for S-wave, respectively. Pulse generator (Model: Wavetek 178, 50...density (9/cmr) P -wave velocity (mis) 6 7 8 9 10 40 50 0 70 80 90 1.20 1.30 140 1,90 2,0 24 2,8 1420 1500 50 100 200- 250 -Water content 300 -e...8217• Poroatty . . Figure 3. Mean grain size, geotechnical properties, and p -wave velocity for core samples at station 1. The values are markedly changed the

  7. Reference Values of Impulse Oscillometric Lung Function Indices in Adults of Advanced Age

    PubMed Central

    Schulz, Holger; Flexeder, Claudia; Behr, Jürgen; Heier, Margit; Holle, Rolf; Huber, Rudolf M.; Jörres, Rudolf A.; Nowak, Dennis; Peters, Annette; Wichmann, H.-Erich; Heinrich, Joachim; Karrasch, Stefan

    2013-01-01

    Background Impulse oscillometry (IOS) is a non-demanding lung function test. Its diagnostic use may be particularly useful in patients of advanced age with physical or mental limitations unable to perform spirometry. Only few reference equations are available for Caucasians, none of them covering the old age. Here, we provide reference equations up to advanced age and compare them with currently available equations. Methods IOS was performed in a population-based sample of 1990 subjects, aged 45–91 years, from KORA cohorts (Augsburg, Germany). From those, 397 never-smoking, lung healthy subjects with normal spirometry were identified and sex-specific quantile regression models with age, height and body weight as predictors for respiratory system impedance, resistance, reactance, and other parameters of IOS applied. Results Women (n = 243) showed higher resistance values than men (n = 154), while reactance at low frequencies (up to 20 Hz) was lower (p<0.05). A significant age dependency was observed for the difference between resistance values at 5 Hz and 20 Hz (R5–R20), the integrated area of low-frequency reactance (AX), and resonant frequency (Fres) in both sexes whereas reactance at 5 Hz (X5) was age dependent only in females. In the healthy subjects (n = 397), mean differences between observed values and predictions for resistance (5 Hz and 20 Hz) and reactance (5 Hz) ranged between −1% and 5% when using the present model. In contrast, differences based on the currently applied equations (Vogel & Smidt 1994) ranged between −34% and 76%. Regarding our equations the indices were beyond the limits of normal in 8.1% to 18.6% of the entire KORA cohort (n = 1990), and in 0.7% to 9.4% with the currently applied equations. Conclusions Our study provides up-to-date reference equations for IOS in Caucasians aged 45 to 85 years. We suggest the use of the present equations particularly in advanced age in order to detect airway dysfunction. PMID:23691036

  8. Influence of frequency on shear fatigue strength of resin composite to enamel bonds using self-etch adhesives.

    PubMed

    Takamizawa, Toshiki; Scheidel, Donal D; Barkmeier, Wayne W; Erickson, Robert L; Tsujimoto, Akimasa; Latta, Mark A; Miyazaki, Masashi

    2016-09-01

    The purpose of this study was to determine the influence of different frequency rates on of bond durability of self-etch adhesives to enamel using shear fatigue strength (SFS) testing. A two-step self-etch adhesive (OX, OptiBond XTR), and two single step self-etch adhesives (GB, G-ӕnial Bond and SU, Scotchbond Universal) were used in this study. The shear fatigue strength (SFS) to enamel was obtained. A staircase method was used to determine the SFS values with 50,000 cycles or until failure occurred. Fatigue testing was performed at frequencies of 5Hz, 10Hz, and 20Hz. For each test condition, 30 specimens were prepared for the SFS testing. Regardless of the bond strength test method, OX showed significantly higher SFS values than the two single-step self-etch adhesives. For each of the three individual self-etch adhesives, there was no significant difference in SFS depending on the frequency rate, although 20Hz results tended to be higher. Regardless of the self-etch adhesive system, frequencies of 5Hz, 10Hz, and 20Hz produced similar results in fatigue strength of resin composite bonded to enamel using 50,000 cycles or until bond failure. Accelerated fatigue testing provides valuable information regarding the long term durability of resin composite to enamel bonding using self-etch adhesive system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Admittance–voltage profiling of Al{sub x}Ga{sub 1−x}N/GaN heterostructures: Frequency dependence of capacitance and conductance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Köhler, K.; Pletschen, W.; Godejohann, B.

    2015-11-28

    Admittance–voltage profiling of Al{sub x}Ga{sub 1−x}N/GaN heterostructures was used to determine the frequency dependent capacitance and conductance of FET devices in the frequency range from 50 Hz to 1 MHz. The nominally undoped low pressure metal-organic vapor-phase epitaxy structures were grown with an Al-content of 30%. An additional 1 nm thick AlN interlayer was placed in one structure before the Al{sub 0.3}Ga{sub 0.7}N layer growth. For frequencies below 10{sup 8} Hz it is convenient to use equivalent circuits to represent electric or dielectric properties of a material, a method widely used, for example, in impedance spectroscopy. We want to emphasize the relation betweenmore » frequency dependent admittance–voltage profiling and the corresponding equivalent circuits to the complex dielectric function. Debye and Drude models are used for the description of the frequency dependent admittance profiles in a range of depletion onset of the two-dimensional electron gas. Capacitance- and conductance-frequency profiles are fitted in the entire measured range by combining both models. Based on our results, we see contributions to the two-dimensional electron gas for our samples from surface states (80%) as well as from background doping in the Al{sub 0.3}Ga{sub 0.7}N barriers (20%). The specific resistance of the layers below the gate is above 10{sup 5} Ω cm for both samples and increases with increasing negative bias, i.e., the layers below the gate are essentially depleted. We propose that the resistance due to free charge carriers, determined by the Drude model, is located between gate and drain and, because of the AlN interlayer, the resistance is lowered by a factor of about 30 if compared to the sample without an AlN layer.« less

  10. Effect of low-magnitude different-frequency whole-body vibration on subchondral trabecular bone microarchitecture, cartilage degradation, bone/cartilage turnover, and joint pain in rabbits with knee osteoarthritis.

    PubMed

    Junbo, Wang; Sijia, Liu; Hongying, Chen; Lei, Liu; Pu, Wang

    2017-06-15

    Whole-body vibration(WBV) has been suggested for the prevention of subchondral bone loss of knee osteoarthritis (OA) . This study examined the effects of different frequency of whole-body vibration on subchondral trabecular bone microarchitecture, cartilage degradation and metabolism of the tibia and femoral condyle bone, and joint pain in an anterior cruciate ligament transection (ACLT)-induced knee osteoarthritisrabbit model. Ninety adult rabbits were divided into six groups: all groups received unilateral ACLT; Group 1, ACLT only; Group 2, 5 Hz WBV; Group 3, 10 Hz WBV; Group 4, 20 Hz WBV; Group 5, 30 Hz WBV; and Group 6, 40 Hz WBV. Pain was tested via weight-bearing asymmetry. Subchondral trabecular bone microarchitecture was examined using in vivo micro-computed tomography. Knee joint cartilage was evaluated by gross morphology, histology, and ECM gene expression level (aggrecan and type II collagen [CTX-II]). Serum bone-specific alkaline phosphatase, N-mid OC, cartilage oligometric protein, CPII, type I collagen, PIIANP, G1/G2 aggrecan levels, and urinary CTX-II were analyzed. After 8 weeks of low-magnitude WBV, the lower frequency (10 Hz and 20 Hz) WBV treatment decreased joint pain and cartilage resorption, accelerated cartilage formation, delayed cartilage degradation especially at the 20 Hz regimen. However, the higher frequencies (30 Hz and 40 Hz) had worse effects, with worse limb function and cartilage volume as well as higher histological scores and cartilage resorption. In contrast, both prevented loss of trabeculae and increased bone turnover. No significant change was observed in the 5 Hz WBV group. Our data demonstrate that the lower frequencies (10 Hz and 20 Hz) of low-magnitude WBV increased bone turnover, delayed cartilage degeneration, and caused a significant functional change of the OA-affected limb in ACLT-induced OA rabbit model but did not reverse OA progression after 8 weeks of treatment.

  11. Preparation-free method for detecting Escherichia coli O157:H7 in the presence of spinach, spring lettuce mix, and ground beef particulates.

    PubMed

    Maraldo, David; Mutharasan, Raj

    2007-11-01

    We show the detection of 100 cells per ml of Escherichia coli O157:H7 in the presence of spinach, spring lettuce mix, and ground beef washes and particulate matter with piezoelectric-excited millimeter-sized cantilever (PEMC) sensors. The PEMC sensors (sensing area, 2 mm2) were immobilized with polyclonal antibody specific to E. coli O157:H7 (EC) and were exposed to 10 aqueous washes of locally purchased spinach, spring lettuce mix, and ground beef for testing if EC was present. Absence of resonance frequency shift indicated that EC was not present in the 30 samples tested. Following the last sample in each food matrix, 1,000 cells per ml of EC were spiked into the sample container, and resonance frequency change was monitored. The total resonance frequency change was 880 +/- 5, 1,875 +/- 8, and 1,417 +/- 4 Hz for spinach, spring lettuce mix, and ground beef, respectively. A mixture of the three food matrices spiked with 100 cells per ml of EC gave a sensor response of 260 +/- 15 Hz. The resonance frequency changes are approximately 40% lower than our previously reported study on ground beef. It is suggested that the reduction in sensitivity is due to differences in pathogen adherence to food matrices, which affects target binding to the sensor surface. We conclude that detection selectivity is conserved in the three food matrices examined and that the magnitude of sensor response is a function of the food matrix.

  12. Tilt and Translation Motion Perception during Off Vertical Axis Rotation

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Reschke, Millard F.; Clement, Gilles

    2006-01-01

    The effect of stimulus frequency on tilt and translation motion perception was studied during constant velocity off-vertical axis rotation (OVAR), and compared to the effect of stimulus frequency on eye movements. Fourteen healthy subjects were rotated in darkness about their longitudinal axis 10deg and 20deg off-vertical at 0.125 Hz, and 20deg offvertical at 0.5 Hz. Oculomotor responses were recorded using videography, and perceived motion was evaluated using verbal reports and a joystick with four degrees of freedom (pitch and roll tilt, mediallateral and anteriorposterior translation). During the lower frequency OVAR, subjects reported the perception of progressing along the edge of a cone. During higher frequency OVAR, subjects reported the perception of progressing along the edge of an upright cylinder. The modulation of both tilt recorded from the joystick and ocular torsion significantly increased as the tilt angle increased from 10deg to 20deg at 0.125 Hz, and then decreased at 0.5 Hz. Both tilt perception and torsion slightly lagged head orientation at 0.125 Hz. The phase lag of torsion increased at 0.5 Hz, while the phase of tilt perception did not change as a function of frequency. The amplitude of both translation perception recorded from the joystick and horizontal eye movements was negligible at 0.125 Hz and increased as a function of stimulus frequency. While the phase lead of horizontal eye movements decreased at 0.5 Hz, the phase of translation perception did not vary with stimulus frequency and was similar to the phase of tilt perception during all conditions. During dynamic linear acceleration in the absence of other sensory input (canal, vision) a change in stimulus frequency alone elicits similar changes in the amplitude of both self motion perception and eye movements. However, in contrast to the eye movements, the phase of both perceived tilt and translation motion is not altered by stimulus frequency. We conclude that the neural processing to distinguish tilt and translation linear acceleration stimuli differs between eye movements and motion perception.

  13. 47 CFR 90.259 - Assignment and use of frequencies in the bands 216-220 MHz and 1427-1432 MHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... assignments will be made after January 1, 2002. (4) In the 217-220 MHz band, the maximum transmitter output... operations will not be authorized. The area of normal day-to-day operations will be described in the... will be assigned with a 6.25 kHz, 12.5 kHz, 25 kHz or 50 kHz channel bandwidth. Frequencies may be...

  14. Oscillation of the human ankle joint in response to applied sinusoidal torque on the foot

    PubMed Central

    Agarwal, Gyan C.; Gottlieb, Gerald L.

    1977-01-01

    1. Low-frequency (3-30 Hz) oscillatory rotation of the ankle joint in plantarflexion—dorsiflexion was generated with a torque motor. Torque, rotation about the ankle and electromyograms (e.m.g.s) for the gastrocnemius—soleus and the anterior tibial muscles were recorded. 2. Fourier coefficients at each drive frequency were used to calculate the effective compliance (ratio of rotation and torque). The compliance has a sharp resonance when tonic, voluntary muscle activity is present. 3. The resonant frequency of compliance is between 3 and 8 Hz. The location of the resonant frequency and the magnitude of the compliance at resonance depend upon both the degree of tonic muscle activity and the amplitude of the driving torque. The resonant frequency increases with increasing tonic activity. 4. With tonic muscle activity, the compliance in the frequency range below resonance increases with increasing amplitudes of driving torque. 5. The e.m.g., when evoked by the rhythmic stretch, lags the start of stretching by between 50 and 70 msec. 6. When tonic muscle activity is present, the resonant frequency of the stretch reflex is between 5 and 6·5 Hz. 7. Following the start of driven oscillation at frequencies near resonance, slowly increasing amplitudes of angular rotation (to a limit) are observed. 8. Distortion (from the sinusoidal wave shape) of angular rotation is frequently observed with drive frequencies between 8 and 12 Hz during which there sometimes occur spontaneous recurrences of oscillation at the drive frequency. For the angular rotation, a significant portion of the power may be in subharmonic frequency components of the drive frequency when that frequency is between 8 and 12 Hz. 9. Self-sustaining oscillation (clonus) near the resonant frequency of the compliance is sometimes observed after the modulation signal to the motor is turned off. This is most often seen when the gastrocnemius—soleus muscles are fatigued. Clonus may be evoked by driven oscillation at any frequency. 10. The hypothesis that physiological tremor, which occurs between 8 and 12 Hz, is a consequence of stretch reflex servo properties seems to be at odds with the observations of resonance in the compliance and of self-generated clonus both occurring in the 5-8 Hz region. PMID:874886

  15. High-Frequency Dusting Versus Conventional Holmium Laser Lithotripsy for Intrarenal and Ureteral Calculi.

    PubMed

    Li, Roger; Ruckle, David; Keheila, Mohamed; Maldonado, Jonathan; Lightfoot, Michelle; Alsyouf, Muhannad; Yeo, Alexander; Abourbih, Samuel R; Olgin, Gaudencio; Arenas, Javier L; Baldwin, D Duane

    2017-03-01

    The efficiency of holmium laser lithotripsy for urolithiasis depends upon several factors, including laser pulse energy and frequency and stone composition and retropulsion. This study investigates the complex interplay between these factors and quantifies lithotripsy efficiency using different laser settings in a benchtop kidney and ureter model. In vitro caliceal and ex vivo porcine ureteral models were constructed. Calcium oxalate monohydrate stones were fragmented using a 200-μm laser fiber. In the caliceal model, stone fragmentation and vaporization rates at settings of 0.6 J/5 Hz, 0.2 J/15 Hz, and 0.2 J/50 Hz were compared. In the ureteral model, fragmentation time, retropulsion rate, fragmentation rate, and fragmented stone weight were compared at settings of 0.6 J/5 Hz and 0.2 J/15 Hz. Retropulsive forces generated at 0.6 J/5 Hz, 0.2 J/15 Hz, and 0.2 J/50 Hz settings were compared. Analysis was performed using Student's t-test and one-way ANOVA. In the caliceal model, the 0.6 J/5 Hz setting fragmented and vaporized stones at a higher rate than the 0.2 J/15 Hz setting (0.072 vs. 0.049 mg/s; p < 0.001). However, when the 0.2 J energy setting was combined with the 50 Hz frequency, the fragmentation rate (0.069 mg/s) was similar to the fragmentation rate at 0.6 J/5 Hz (0.072 mg/s; p = 0.677). In the ureteral model, the 0.6 J/5 Hz setting produced higher fragmentation rates (0.089 vs. 0.049 mg/s; p < 0.001), but resulted in significantly lower fragmented stone weight overall (16.815 vs. 25.485 mg; p = 0.009) due to higher retropulsion rates (0.732 vs. 0.213 mm/s; p < 0.001). Retropulsive forces decreased significantly when pulse energy decreased from 0.6 to 0.2 J (0.907 vs. 0.223 N; p < 0.001). Frequency did not affect retropulsive force at 15 and 50 Hz settings (0.223 vs. 0.288 N; p = 0.509). Laser lithotripsy of calcium oxalate monohydrate stones in the ureter should be performed using the low-energy, moderate-frequency dusting setting to minimize retropulsion and maximize efficiency. In the renal calix, the low-energy high-frequency setting performed similarly to the high-energy low-frequency setting.

  16. Ship noise extends to frequencies used for echolocation by endangered killer whales.

    PubMed

    Veirs, Scott; Veirs, Val; Wood, Jason D

    2016-01-01

    Combining calibrated hydrophone measurements with vessel location data from the Automatic Identification System, we estimate underwater sound pressure levels for 1,582 unique ships that transited the core critical habitat of the endangered Southern Resident killer whales during 28 months between March, 2011, and October, 2013. Median received spectrum levels of noise from 2,809 isolated transits are elevated relative to median background levels not only at low frequencies (20-30 dB re 1 µPa(2)/Hz from 100 to 1,000 Hz), but also at high frequencies (5-13 dB from 10,000 to 96,000 Hz). Thus, noise received from ships at ranges less than 3 km extends to frequencies used by odontocetes. Broadband received levels (11.5-40,000 Hz) near the shoreline in Haro Strait (WA, USA) for the entire ship population were 110 ± 7 dB re 1 µPa on average. Assuming near-spherical spreading based on a transmission loss experiment we compute mean broadband source levels for the ship population of 173 ± 7 dB re 1 µPa 1 m without accounting for frequency-dependent absorption. Mean ship speed was 7.3 ± 2.0 m/s (14.1 ± 3.9 knots). Most ship classes show a linear relationship between source level and speed with a slope near +2 dB per m/s (+1 dB/knot). Spectrum, 1/12-octave, and 1/3-octave source levels for the whole population have median values that are comparable to previous measurements and models at most frequencies, but for select studies may be relatively low below 200 Hz and high above 20,000 Hz. Median source spectrum levels peak near 50 Hz for all 12 ship classes, have a maximum of 159 dB re 1 µPa(2)/Hz @ 1 m for container ships, and vary between classes. Below 200 Hz, the class-specific median spectrum levels bifurcate with large commercial ships grouping as higher power noise sources. Within all ship classes spectrum levels vary more at low frequencies than at high frequencies, and the degree of variability is almost halved for classes that have smaller speed standard deviations. This is the first study to present source spectra for populations of different ship classes operating in coastal habitats, including at higher frequencies used by killer whales for both communication and echolocation.

  17. Interactive Effects of High- and Low-Frequency Loading on Fatigue.

    DTIC Science & Technology

    1985-05-01

    were observed for an air environment between frequencies of 100 and 375 Hz . In dry argon, however, the results for 100 Hz were slightly higher than...those at 375 Hz . A very extensive study of fatigue crack growth properties of titanium alloys usPd in aircraft engine compressors was performed by

  18. Effects of Acoustic Modulation and Mixed Fuel on Flame Synthesis of Carbon Nanomaterials in an Atmospheric Environment

    PubMed Central

    Hu, Wei-Chieh; Sari, Shanti Kartika; Hou, Shuhn-Shyurng; Lin, Ta-Hui

    2016-01-01

    In this study, methane–ethylene jet diffusion flames modulated by acoustic excitation in an atmospheric environment were used to investigate the effects of acoustic excitation frequency and mixed fuel on nanomaterial formation. Acoustic output power was maintained at a constant value of 10 W, while the acoustic excitation frequency was varied (f = 0–90 Hz). The results show that the flame could not be stabilized on the port when the ethylene volume concentration (ΩE) was less than 40% at f = 10 Hz, or when ΩE = 0% (i.e., pure methane) at f = 90 Hz. The reason for this is that the flame had a low intensity and was extinguished by the entrained air due to acoustic modulation. Without acoustic excitation (f = 0 Hz), the flame was comprised of a single-layer structure for all values of ΩE, and almost no carbon nanomaterials were synthesized. However, with acoustic excitation, a double-layer flame structure was generated for frequencies close to both the natural flickering frequency and the acoustically resonant frequency. This double-layer flame structure provided a favorable flame environment for the fabrication of carbon nanomaterials. Consequently, the synthesis of carbon nano-onions was significantly enhanced by acoustic excitation near both the natural flickering frequency and the acoustically resonant frequency. At f = 20 Hz (near the natural flickering frequency) for 0% ≤ ΩE ≤ 100%, a quantity of carbon nano-onions (CNOs) piled like bunches of grapes was obtained as a result of improved mixing of the fuel with ambient air. High-density CNOs were also produced at f = 70 Hz (close to the acoustically resonant frequency) for 40% ≤ ΩE ≤ 100%. Furthermore, carbon nanotubes (CNTs) were synthesized only at 80 Hz for ΩE = 0%. The suitable temperature range for the synthesis of CNTs was slightly higher than that for the formation of CNOs (about 600 °C for CNTs; 510–600 °C for CNOs). PMID:28774059

  19. A micromachined efficient parametric array loudspeaker with a wide radiation frequency band.

    PubMed

    Je, Yub; Lee, Haksue; Been, Kyounghun; Moon, Wonkyu

    2015-04-01

    Parametric array (PA) loudspeakers generate directional audible sound via the PA effect, which can make private listening possible. The practical applications of PA loudspeakers include information technology devices that require large power efficiency transducers with a wide frequency bandwidth. Piezoelectric micromachined ultrasonic transducers (PMUTs) are compact and efficient units for PA sources [Je, Lee, and Moon, Ultrasonics 53, 1124-1134 (2013)]. This study investigated the use of an array of PMUTs to make a PA loudspeaker with high power efficiency and wide bandwidth. The achievable maximum radiation bandwidth of the driver was calculated, and an array of PMUTs with two distinct resonance frequencies (f1 = 100 kHz, f2 = 110 kHz) was designed. Out-of-phase driving was used with the dual-resonance transducer array to increase the bandwidth. The fabricated PMUT array exhibited an efficiency of up to 71%, together with a ±3-dB bandwidth of 17 kHz for directly radiated primary waves, and 19.5 kHz (500 Hz to 20 kHz) for the difference frequency waves (with equalization).

  20. Generating visual flickers for eliciting robust steady-state visual evoked potentials at flexible frequencies using monitor refresh rate.

    PubMed

    Nakanishi, Masaki; Wang, Yijun; Wang, Yu-Te; Mitsukura, Yasue; Jung, Tzyy-Ping

    2014-01-01

    In the study of steady-state visual evoked potentials (SSVEPs), it remains a challenge to present visual flickers at flexible frequencies using monitor refresh rate. For example, in an SSVEP-based brain-computer interface (BCI), it is difficult to present a large number of visual flickers simultaneously on a monitor. This study aims to explore whether or how a newly proposed frequency approximation approach changes signal characteristics of SSVEPs. At 10 Hz and 12 Hz, the SSVEPs elicited using two refresh rates (75 Hz and 120 Hz) were measured separately to represent the approximation and constant-period approaches. This study compared amplitude, signal-to-noise ratio (SNR), phase, latency, scalp distribution, and frequency detection accuracy of SSVEPs elicited using the two approaches. To further prove the efficacy of the approximation approach, this study implemented an eight-target BCI using frequencies from 8-15 Hz. The SSVEPs elicited by the two approaches were found comparable with regard to all parameters except amplitude and SNR of SSVEPs at 12 Hz. The BCI obtained an averaged information transfer rate (ITR) of 95.0 bits/min across 10 subjects with a maximum ITR of 120 bits/min on two subjects, the highest ITR reported in the SSVEP-based BCIs. This study clearly showed that the frequency approximation approach can elicit robust SSVEPs at flexible frequencies using monitor refresh rate and thereby can largely facilitate various SSVEP-related studies in neural engineering and visual neuroscience.

  1. Value of electrical stimulation and high frequency oscillations (80–500 Hz) in identifying epileptogenic areas during intracranial EEG recordings

    PubMed Central

    Jacobs, Julia; Zijlmans, Maeike; Zelmann, Rina; Olivier, André; Hall, Jeffery; Gotman, Jean; Dubeau, François

    2013-01-01

    Summary Purpose Electrical stimulation (ES) is used during intracranial electroencephalography (EEG) investigations to delineate epileptogenic areas and seizure-onset zones (SOZs) by provoking afterdischarges (ADs) or patients’ typical seizure. High frequency oscillations (HFOs—ripples, 80–250 Hz; fast ripples, 250–500 Hz) are linked to seizure onset. This study investigates whether interictal HFOs are more frequent in areas with a low threshold to provoke ADs or seizures. Methods Intracranial EEG studies were filtered at 500 Hz and sampled at 2,000 Hz. HFOs were visually identified. Twenty patients underwent ES, with gradually increasing currents. Results were interpreted as agreeing or disagreeing with the intracranial study (clinical-EEG seizure onset defined the SOZ). Current thresholds provoking an AD or seizure were correlated with the rate of HFOs of each channel. Results ES provoked a seizure in 12 and ADs in 19 patients. Sixteen patients showed an ES response inside the SOZ, and 10 had additional areas with ADs. The response was more specific for mesiotemporal than for neocortical channels. HFO rates were negatively correlated with thresholds for ES responses; especially in neo-cortical regions; areas with low threshold and high HFO rate were colocalized even outside the SOZ. Discussion Areas showing epileptic HFOs colocalize with those reacting to ES. HFOs may represent a pathologic correlate of regions showing an ES response; both phenomena suggest a more widespread epileptogenicity. PMID:19845730

  2. Discovery of the Neutron Star Spin Frequency in EXO 0748-676

    NASA Technical Reports Server (NTRS)

    Villarreal, Adam R.; Strohmayer, Tod E.

    2004-01-01

    We report the results of a search for burst oscillations during thermonuclear X-ray bursts from the low mass X-ray binary (LMXB) EXO 0748-676. With the proportional counter array (PCA) onboard the Rossi X-ray Timing Explorer (RXTE) we have detected a 45 Hz oscillation in the average power spectrum of 38 thermonuclear X-ray bursts from this source. We computed power spectra with 1 Hz frequency resolution for both the rising and decaying portions of 38 X-ray bursts from the public RXTE archive. We averaged the 1 Hz power spectra and detected a significant signal at 45 Hz in the decaying phases of the bursts. The signal is detected at a significance level of 4 x 10 (exp -8) similar signal was detected in the rising intervals. The oscillation peak is unresolved at 1 Hz frequency resolution, indicating an oscillation quality factor, Q = nu (sub 0)/Delta nu (sub fwhm) greater than 45, and the average signal amplitude is approximately equal to 3% (rms) The detection of 45 Hz burst oscillations from EXO 0748-676 provides compelling evidence that this is the neutron star spin frequency in this system. We use the inferred spin frequency to model the widths of absorption lines from the neutron star surface and show that the widths of the absorption lines from EXO 0748-676 recently reported by Cottam et al. are consistent with a 45 Hz spin frequency as long as the neutron star radius is in the range from about 9.5 - 15 km. With a known spin frequency, precise modelling of the line profiles from EXO 0748-676 holds great promise for constraining the dense matter equation of state.

  3. Synthesis of nitrogen-containing carbon by solution plasma in aniline with high-repetition frequency discharges

    NASA Astrophysics Data System (ADS)

    Hyun, Koangyong; Ueno, Tomonaga; Saito, Nagahiro

    2016-01-01

    Nitrogen-containing carbon nanoparticles were synthesized in aniline by solution plasma with high-repetition frequency discharges. We developed a bipolar pulsed power supply that can apply high-repetition frequencies ranging from 25 to 200 kHz. By utilizing high-repetition frequencies, conductive carbons were directly synthesized. The crystallinity was increased and H/C ratio of carbon was decreased. Furthermore, nitrogen atoms were simultaneously embedded in the carbon matrix. Due to the presence of nitrogen atoms, the conductivity and electrocatalytic activity of the samples were remarkably improved compared to that of a pure carbon matrix synthesized from a benzene precursor.

  4. Enhancing interaural-delay-based extents of laterality at high frequencies by using ``transposed stimuli''

    NASA Astrophysics Data System (ADS)

    Bernstein, Leslie R.; Trahiotis, Constantine

    2003-06-01

    An acoustic pointing task was used to determine whether interaural temporal disparities (ITDs) conveyed by high-frequency ``transposed'' stimuli would produce larger extents of laterality than ITDs conveyed by bands of high-frequency Gaussian noise. The envelopes of transposed stimuli are designed to provide high-frequency channels with information similar to that conveyed by the waveforms of low-frequency stimuli. Lateralization was measured for low-frequency Gaussian noises, the same noises transposed to 4 kHz, and high-frequency Gaussian bands of noise centered at 4 kHz. Extents of laterality obtained with the transposed stimuli were greater than those obtained with bands of Gaussian noise centered at 4 kHz and, in some cases, were equivalent to those obtained with low-frequency stimuli. In a second experiment, the general effects on lateral position produced by imposed combinations of bandwidth, ITD, and interaural phase disparities (IPDs) on low-frequency stimuli remained when those stimuli were transposed to 4 kHz. Overall, the data were fairly well accounted for by a model that computes the cross-correlation subsequent to known stages of peripheral auditory processing augmented by low-pass filtering of the envelopes within the high-frequency channels of each ear.

  5. Effects of Sound Frequency on Audiovisual Integration: An Event-Related Potential Study

    PubMed Central

    Yang, Weiping; Yang, Jingjing; Gao, Yulin; Tang, Xiaoyu; Ren, Yanna; Takahashi, Satoshi; Wu, Jinglong

    2015-01-01

    A combination of signals across modalities can facilitate sensory perception. The audiovisual facilitative effect strongly depends on the features of the stimulus. Here, we investigated how sound frequency, which is one of basic features of an auditory signal, modulates audiovisual integration. In this study, the task of the participant was to respond to a visual target stimulus by pressing a key while ignoring auditory stimuli, comprising of tones of different frequencies (0.5, 1, 2.5 and 5 kHz). A significant facilitation of reaction times was obtained following audiovisual stimulation, irrespective of whether the task-irrelevant sounds were low or high frequency. Using event-related potential (ERP), audiovisual integration was found over the occipital area for 0.5 kHz auditory stimuli from 190–210 ms, for 1 kHz stimuli from 170–200 ms, for 2.5 kHz stimuli from 140–200 ms, 5 kHz stimuli from 100–200 ms. These findings suggest that a higher frequency sound signal paired with visual stimuli might be early processed or integrated despite the auditory stimuli being task-irrelevant information. Furthermore, audiovisual integration in late latency (300–340 ms) ERPs with fronto-central topography was found for auditory stimuli of lower frequencies (0.5, 1 and 2.5 kHz). Our results confirmed that audiovisual integration is affected by the frequency of an auditory stimulus. Taken together, the neurophysiological results provide unique insight into how the brain processes a multisensory visual signal and auditory stimuli of different frequencies. PMID:26384256

  6. Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS

    PubMed Central

    Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru

    2016-01-01

    The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2–8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied. PMID:27079873

  7. DFB fiber laser static strain sensor based on beat frequency interrogation with a reference fiber laser locked to a FBG resonator.

    PubMed

    Huang, Wenzhu; Feng, Shengwen; Zhang, Wentao; Li, Fang

    2016-05-30

    We report on a high-resolution static strain sensor developed with distributed feedback (DFB) fiber laser. A reference FBG resonator is used for temperature compensation. Locking another independent fiber laser to the resonator using the Pound-Drever-Hall technique results in a strain power spectral density better than Sε(f) = (4.6 × 10-21) ε2/Hz in the frequency range from 1 Hz to 1 kHz, corresponding to a minimum dynamic strain resolution of 67.8 pε/√Hz. This frequency stabilized fiber laser is proposed to interrogate the sensing DFB fiber laser by the beat frequency principle. As a reasonable DFB fiber laser setup is realized, a narrow beat frequency line-width of 3.23 kHz and a high beat frequency stability of 0.036 MHz in 15 minutes are obtained in the laboratory test, corresponding to a minimum static strain resolution of 270 pε. This is the first time that a sub-0.5 nε level for static strain measurement using DFB fiber laser is demonstrated.

  8. The effect of recording and analysis bandwidth on acoustic identification of delphinid species.

    PubMed

    Oswald, Julie N; Rankin, Shannon; Barlow, Jay

    2004-11-01

    Because many cetacean species produce characteristic calls that propagate well under water, acoustic techniques can be used to detect and identify them. The ability to identify cetaceans to species using acoustic methods varies and may be affected by recording and analysis bandwidth. To examine the effect of bandwidth on species identification, whistles were recorded from four delphinid species (Delphinus delphis, Stenella attenuata, S. coeruleoalba, and S. longirostris) in the eastern tropical Pacific ocean. Four spectrograms, each with a different upper frequency limit (20, 24, 30, and 40 kHz), were created for each whistle (n = 484). Eight variables (beginning, ending, minimum, and maximum frequency; duration; number of inflection points; number of steps; and presence/absence of harmonics) were measured from the fundamental frequency of each whistle. The whistle repertoires of all four species contained fundamental frequencies extending above 20 kHz. Overall correct classification using discriminant function analysis ranged from 30% for the 20-kHz upper frequency limit data to 37% for the 40-kHz upper frequency limit data. For the four species included in this study, an upper bandwidth limit of at least 24 kHz is required for an accurate representation of fundamental whistle contours.

  9. Low noise erbium fiber fs frequency comb based on a tapered-fiber carbon nanotube design.

    PubMed

    Wu, Tsung-Han; Kieu, K; Peyghambarian, N; Jones, R J

    2011-03-14

    We report on a low noise all-fiber erbium fs frequency comb based on a simple and robust tapered-fiber carbon nanotube (tf-CNT) design. We mitigate dominant noise sources to show that the free-running linewidth of the carrier-envelope offset frequency (fceo) can be comparable to the best reported performance to date for fiber-based frequency combs. A free-running fceo linewidth of ~20 kHz is demonstrated, corresponding to an improvement of ~30 times over previous work based on a CNT mode-locked fiber laser [Opt. Express 18, 1667 (2010)]. We also demonstrate the use of an acousto-optic modulator external to the laser cavity to stabilize fceo, enabling a 300 kHz feedback control bandwidth. The offset frequency is phase-locked with an in-loop integrated phase noise of ~0.8 rad from 10Hz to 400kHz. We show a resolution-limited linewidth of ~1 Hz, demonstrating over 90% of the carrier power within the coherent fceo signal. The results demonstrate that the relatively simple tf-CNT fiber laser design can provide a compact, robust and high-performance fs frequency comb.

  10. Factors responsible for remote-frequency masking in children and adultsa)

    PubMed Central

    Leibold, Lori J.; Buss, Emily

    2016-01-01

    Susceptibility to remote-frequency masking in children and adults was evaluated with respect to three stimulus features: (1) masker bandwidth, (2) spectral separation of the signal and masker, and (3) gated versus continuous masker presentation. Listeners were 4- to 6-year-olds, 7- to 10-year-olds, and adults. Detection thresholds for a 500-ms, 2000-Hz signal were estimated in quiet or presented with a band of noise in one of four frequency regions: 425–500 Hz, 4000–4075 Hz, 8000–8075 Hz, or 4000–10 000 Hz. In experiment 1, maskers were gated on in each 500-ms interval of a three-interval, forced-choice adaptive procedure. Masking was observed for all ages in all maskers, but the greatest masking was observed for the 4000–4075 Hz masker. These findings suggest that signal/masker spectral proximity plays an important role in remote-frequency masking, even when peripheral excitation associated with the signal and masker does not overlap. Younger children tended to have more masking than older children or adults, consistent with a reduced ability to segregate simultaneous sounds and/or listen in a frequency-selective manner. In experiment 2, detection thresholds were estimated in the same noises, but maskers were presented continuously. Masking was reduced for all ages relative to gated conditions, suggesting improved segregation and/or frequency-selective listening. PMID:28040030

  11. Equivalence and test-retest reproducibility of conventional and extended-high-frequency audiometric thresholds obtained using pure-tone and narrow-band-noise stimuli.

    PubMed

    John, Andrew B; Kreisman, Brian M

    2017-09-01

    Extended high-frequency (EHF) audiometry is useful for evaluating ototoxic exposures and may relate to speech recognition, localisation and hearing aid benefit. There is a need to determine whether common clinical practice for EHF audiometry using tone and noise stimuli is reliable. We evaluated equivalence and compared test-retest (TRT) reproducibility for audiometric thresholds obtained using pure tones and narrowband noise (NBN) from 0.25 to 16 kHz. Thresholds and test-retest reproducibility for stimuli in the conventional (0.25-6 kHz) and EHF (8-16 kHz) frequency ranges were compared in a repeated-measures design. A total of 70 ears of adults with normal hearing. Thresholds obtained using NBN were significantly lower than thresholds obtained using pure tones from 0.5 to 16 kHz, but not 0.25 kHz. Good TRT reproducibility (within 2 dB) was observed for both stimuli at all frequencies. Responses at the lower limit of the presentation range for NBN centred at 14 and 16 kHz suggest unreliability for NBN as a threshold stimulus at these frequencies. Thresholds in the conventional and EHF ranges showed good test-retest reproducibility, but differed between stimulus types. Care should be taken when comparing pure-tone thresholds with NBN thresholds especially at these frequencies.

  12. Application of ultrasound in chicken breast during chilling by immersion promotes a fast and uniform cooling.

    PubMed

    Flores, Diego Rafael Martins; Brasil, Carla Cristina Bauermann; Campagnol, Paulo Cezar Bastianello; Jacob-Lopes, Eduardo; Zepka, Leila Queiroz; Wagner, Roger; Menezes, Cristiano Ragagnin; Barin, Juliano Smanioto; Flores, Erico Marlon Moraes; Cichoski, Alexandre José

    2018-07-01

    The initial objective of the study was to evaluate different operation modes (sweep and normal) and frequencies (25 and 130 kHz) of ultrasound in pre-chilling of breast chicken cylinders (BCC) immersed in water at 10 °C during 10 min. The second objective was to study the effect of the immersion time (5, 10, 15, 20, and 30 min) using the best operation mode and frequency obtained in the pre-chilling of the BCC in water at 10 °C. Pre-chilling was evaluated in both stages by infrared thermography, and the percentages of water absorption were determined in the second stage. The application of US at 130 kHz and normal operation mode provided a reduction of temperature on the surface of BBC higher (≈19.6%) than untreated samples. Also, compared to control, the US-treated samples in these conditions presented a more uniform cooling rate (≈22.3%) and higher water absorption (≈113%). Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Research of built-in self test technology on cable-free self-positioning seismograph

    NASA Astrophysics Data System (ADS)

    Huaizhu, Z.; Lin, J.; Chen, Z.; Zhang, L.; Yang, H.; Zheng, F.

    2011-12-01

    Cable-free self-positioning seismograph is the key instrument and equipment required for deep seismic exploration in China. In order to measure the performance of seismic data acquisition systems whether meet exploration requirements , to ensure the accuracy of seismic data, and to ensure equipment reliability and stability, a built-in self test solution of the cable-free self-positioning seismic recorder is provided. Within a 24-bits Σ-Δ DAC, the seismograph can produce sine, step, pulse and other high-precision analog test signal, with dynamic range of 120dB or more, through the FPGA to control the analog multiplexer switching the input signal acquisition channels, and start the 24-bit Σ-Δ ADC in the instrument internal simultaneously to acquisition the test signal data, carries on the fast Fournier transformation by instrument internal CPU, to achieve the instrument of analysis and calculation of performance indicators, including: the equivalent noise and drift, common mode rejection ratio (CMRR), crosstalk, harmonic distortion, dynamic range, channel response consistency, detector impulse response , etc. A lot of testing experiments about the various parameters were performed and studied currently. By setting different sampling rate (1Hz, 5Hz, ..., 4kHz), each of the measurement system noise level was measured, and the maximum noise is about 0.5μV; the crosstalk between channels was tested using the 31.25Hz sine wave, the result is more than-120dB with sampling rate of 1kHz; the harmonic distortion was measured by adding the high-precision sine wave signals of different frequencies, such as 500Hz, 250 Hz, 125 Hz, 62.5 Hz, 31.25 Hz, 15.625 Hz, 7.812 Hz, 3.90625Hz, etc. the calculated results is in-118dB or more. The experimental results show that, the parameters of the cable-free self-positioning of the seismic recorder meet the technical requirements for the deep exploration, compared to the corresponding parameters with the 428XL seismograph of the French Sercel company, the instrument in performance has reached the advanced level of overseas equipment.

  14. Effects of mechanical vibration on proliferation and osteogenic differentiation of human periodontal ligament stem cells.

    PubMed

    Zhang, Chunxiang; Li, Ji; Zhang, Linkun; Zhou, Yi; Hou, Weiwei; Quan, Huixin; Li, Xiaoyu; Chen, Yangxi; Yu, Haiyang

    2012-10-01

    Paradental tissues (alveolar bone, periodontal ligament (PDL), and gingiva) have the capacity to adapt to their functional environment. The principal cellular elements of the PDL play an important role in normal function, regeneration of periodontal tissue and in orthodontic treatment. Recently, several studies have shown that low-magnitude, high-frequency (LMHF) mechanical vibration can positively influence bone homeostasis; however, the mechanism and optimal conditions for LMHF mechanical vibration have not been elucidated. It has been speculated that LMHF mechanical vibration stimulations have a favourable influence on osteocytes, osteoblasts and their precursors, thereby enhancing the expression of osteoblastic genes involved in bone formation and remodelling. The objective of this study was to test the effect of LMHF mechanical vibration on proliferation and osteogenic differentiation of human PDL stem cells (PDLSCs). Human PDLSCs were isolated from premolar teeth and randomized into vibration (magnitude: 0.3g; frequency: 10-180 Hz; 30 min/24h) and static cultures. The effect of vibration on PDLSC proliferation, differentiation and osteogenic potential was assessed at the genetic and protein level. After LMHF mechanical vibration, PDLSC proliferation was decreased; however, this was accompanied by increased markers of osteogenesis in a frequency-dependent manner. Specifically, alkaline phosphatase activity gradually increased with the frequency of vibration, to a peak at 50 Hz, and the level of osteocalcin was significantly higher than control following vibration at 40 Hz, 50 Hz, 60 Hz, 90 Hz and 120 Hz. Levels of Col-I, Runx2 and Osterix were significantly increased by LMHF mechanical vibration at frequencies of 40 Hz and 50 Hz. Our data demonstrates that LMHF mechanical vibration promotes PDLSC osteogenic differentiation and implies the existence of a frequency-dependent effect of vibration on determining PDLSC commitment to the osteoblast lineage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Two-tone suppression in the cricket, Eunemobius carolinus (Gryllidae, Nemobiinae)

    NASA Astrophysics Data System (ADS)

    Farris, Hamilton E.; Hoy, Ronald R.

    2002-03-01

    Sounds with frequencies >15 kHz elicit an acoustic startle response (ASR) in flying crickets (Eunemobius carolinus). Although frequencies <15 kHz do not elicit the ASR when presented alone, when presented with ultrasound (40 kHz), low-frequency stimuli suppress the ultrasound-induced startle. Thus, using methods similar to those in masking experiments, we used two-tone suppression to assay sensitivity to frequencies in the audio band. Startle suppression was tuned to frequencies near 5 kHz, the frequency range of male calling songs. Similar to equal loudness contours measured in humans, however, equal suppression contours were not parallel, as the equivalent rectangular bandwidth of suppression tuning changed with increases in ultrasound intensity. Temporal integration of suppressor stimuli was measured using nonsimultaneous presentations of 5-ms pulses of 6 and 40 kHz. We found that no suppression occurs when the suppressing tone is >2 ms after and >5 ms before the ultrasound stimulus, suggesting that stimulus overlap is a requirement for suppression. When considered together with our finding that the intensity of low-frequency stimuli required for suppression is greater than that produced by singing males, the overlap requirement suggests that two-tone suppression functions to limit the ASR to sounds containing only ultrasound and not to broadband sounds that span the audio and ultrasound range.

  16. Decoding 3-D Reach and Grasp Kinematics from High-Frequency Local Field Potentials in Primate Primary Motor Cortex

    PubMed Central

    Zhuang, Jun; Vargas-Irwin, Carlos; Donoghue, John P.

    2011-01-01

    Intracortical microelectrode array recordings generate a variety of neural signals with potential application as control signals in neural interface systems. Previous studies have focused on single and multiunit activity, as well as low frequency local field potentials (LFPs), but have not explored higher frequency (>200 Hz) LFPs. In addition, the potential to decode three dimensional (3-D) reach and grasp kinematics based on LFPs has not been demonstrated. Here, we use mutual information and decoding analyses to probe the information content about 3-D reaching and grasping of 7 different LFP frequency bands in the range of 0.3 Hz – 400 Hz. LFPs were recorded via 96-microelectrode arrays in primary motor cortex (M1) of two monkeys performing free reaching to grasp moving objects. Mutual information analyses revealed that higher frequency bands (e.g. 100 – 200 Hz and 200 – 400 Hz) carried the most information about the examined kinematics. Furthermore, Kalman filter decoding revealed that broadband high frequency LFPs, likely reflecting multiunit activity, provided the best decoding performance as well as substantial accuracy in reconstructing reach kinematics, grasp aperture and aperture velocity. These results indicate that LFPs, especially high frequency bands, could be useful signals for neural interfaces controlling 3-D reach and grasp kinematics. PMID:20403782

  17. AC conduction of Ba1-xCaxTiO3 and BZT-BCTx

    NASA Astrophysics Data System (ADS)

    Khien, Nguyen Van; Huy, Than Trong; Hong, Le Van

    2018-03-01

    Ba1-xCaxTiO3 (BCTx), (x =0.0-0.3) and Ba0.8Zr0.2TiO3-Ba1-xCaxTiO3 (BZT-BCTx), (x=0.15-0.35) were fabricated by the solid state reaction method. Phase structure of the material samples was identified by X-ray diffraction. The impedance versus frequency in a range of 100 Hz to 2.5 MHz was measured for all the samples at room temperature. AC conductivity versus frequency of the BCTx and BZT-BCTx was evaluated and fitted by using the extended Universal Dielectric Response (UDR) equations. The fitting results were discussed in detail and shown that the localized reorientation polarization-based mechanism is most contributed in BCTx matrial samples. Basically both two the hopping polaron and polarization mechanisms play roles in BZT-BCTx material samples. In contrary the short-range polaron hopping is dominated in ac conductivity of BZT-BCTx material samples in low frequency range.

  18. Regional variation of coda Q in Kopili fault zone of northeast India and its implications

    NASA Astrophysics Data System (ADS)

    Bora, Nilutpal; Biswas, Rajib; Dobrynina, Anna A.

    2018-01-01

    Kopili fault has been experiencing higher seismic and tectonic activity during the recent years. These kind of active tectonics can be inspected by examining coda-wave attenuation and its dependence with frequency. Exploiting single back-scattering model, we have endeavored to measure coda Q and its associated parameters such as frequency dependent factor (n) and attenuation coefficient (γ) covering seven lapse-time windows spanning from 30 to 90 s and central frequencies 1.5, 3.5, 6, 9 and 12 Hz. The average estimated values of QC increases with frequency and lapse time window from 114 at frequency 1.5 Hz to 1563 at frequency 12 Hz for 30 s window length, and from 305 at frequency 1.5 Hz to 2135 at frequency 12 Hz for 90 s window length. The values of Q0 and n are also estimated for the entire Kopili fault zone. For this study region, the Q0 values vary from 62 to 348 and n varies from 0.57 to 1.51 within the frequency range 1.5 to 12 Hz. Furthermore, depth variation of attenuation of this region reveals that there is velocity anomaly at depth 210-220 km as there arises sharp changes in γ and n which are supported by available data, reported by other researcher for this region. Finally, we have tried to separate the intrinsic and scattering attenuation for this area. It is observed that the entire region is dominated by mainly scattering attenuation, but we can see an increase in intrinsic attenuation with depths in two stations namely TZR and BKD. Furthermore, the obtained results are comparable with the available global data.

  19. Somatic evoked high-frequency magnetic oscillations reflect activity of inhibitory interneurons in the human somatosensory cortex.

    PubMed

    Hashimoto, I; Mashiko, T; Imada, T

    1996-05-01

    High-frequency potential oscillations in the range of 300-900 Hz have recently been shown to concur with the primary response (N20) of the somatosensory cortex in awake humans. However, the physiological mechanisms of the high-frequency oscillations remained undetermined. We addressed the issue by analyzing magnetic fields during wakefulness and sleep over the left hemisphere to right median nerve stimulation with a wide bandpass (0.1-2000 Hz) recording with subsequent high-pass (> 300 Hz) and low-pass (< 300 Hz) filtering. With wide bandpass recordings, high-frequency magnetic oscillations with the main signal energy at 580-780 Hz were superimposed on the N20m during wakefulness. Isofield mapping at each peak of the high-pass filtered and isolated high-frequency oscillations showed a dipolar pattern and the estimated source for these peaks was the primary somatosensory cortex (area 3b) very close to that for the N20m peak. During sleep, the high-frequency oscillations showed dramatic diminution in amplitude while the N20m amplitude exhibited a moderate increment. This reciprocal relation between the high-frequency oscillations and the N20m during a wake-sleep cycle suggests that they represent different generator substrates. We speculate that the high-frequency oscillations represent a localized activity of the GABAergic inhibitory interneurons of layer 4, which have been shown in animal experiments to respond monosynaptically to thalamo-cortical input with a high-frequency (600-900 Hz) burst of short duration spikes. On the other hand, the underlying N20m represents activity of pyramidal neurons which receive monosynaptic excitatory input from the thalamus as well as a feed-forward inhibition from the interneurons.

  20. Site effect classification based on microtremor data analysis using a concentration-area fractal model

    NASA Astrophysics Data System (ADS)

    Adib, A.; Afzal, P.; Heydarzadeh, K.

    2015-01-01

    The aim of this study is to classify the site effect using concentration-area (C-A) fractal model in Meybod city, central Iran, based on microtremor data analysis. Log-log plots of the frequency, amplification and vulnerability index (k-g) indicate a multifractal nature for the parameters in the area. The results obtained from the C-A fractal modelling reveal that proper soil types are located around the central city. The results derived via the fractal modelling were utilized to improve the Nogoshi and Igarashi (1970, 1971) classification results in the Meybod city. The resulting categories are: (1) hard soil and weak rock with frequency of 6.2 to 8 Hz, (2) stiff soil with frequency of about 4.9 to 6.2 Hz, (3) moderately soft soil with the frequency of 2.4 to 4.9 Hz, and (4) soft soil with the frequency lower than 2.4 Hz.

Top