Sample records for i-125 seed implant

  1. Preventive effects of 125I seeds on benign restenosis following esophageal stent implantation in a dog model

    PubMed Central

    GAN, ZHEN; JING, JIAN; ZHU, GUANGYU; QIN, YONGLIN; TENG, GAOJUN; GUO, JINHE

    2015-01-01

    The present study aimed to evaluate the effects of iodine-125 (125I) seeds on the proliferation of primary esophageal fibroblasts in dogs, and to assess the safety and preventive efficacy of 125I seed-pre-loaded esophageal stents in benign restenosis following implantation. Primary fibroblasts were cultured with various 125I seed activities, which were then evaluated using cell proliferation and apoptosis assays as well as cell cycle analysis using Annexin V/propidium iodide (PI) double staining and PI staining. Prior to sacrification, animals were submitted to esophageal radiography under digital subtraction angiography. Esophageal tissues were collected and examined for macroscopic, microscopic and pathological alterations. The results demonstrated a significant and dose-dependent inhibition of fibroblast proliferation and increased apoptosis following exposure to 125I seeds. G0/G1 fibroblast populations increased in a dose-dependent manner following treatment with 125I seeds, in contrast to cells in S phase. Four weeks following implantation, α-smooth muscle actin and proliferating cell nuclear antigen expression levels in the experimental group were significantly lower compared with those in the control group; in addition, eight weeks following implantation, esophageal inner diameters were increased in the experimental group. 125I seeds inhibited proliferation of dog esophageal fibroblasts via cell cycle arrest and apoptosis. In conclusion, 125I seed-pre-loaded esophageal stents inhibited benign hyperplasia in the upper edge of the stent to a certain extent, which relieved benign restenosis following implantation with a good safety profile. PMID:25543838

  2. Trans-bronchoscopy with implantation of 125I radioactive seeds in patients with pulmonary atelectasis induced by lung cancer.

    PubMed

    Lu, Mingjian; Pu, Deli; Zhang, Weidong; Liao, Jiangrong; Zhang, Tao; Yang, Guang; Liu, Zhenyin; Singh, Sristi; Gao, Fei; Zhang, Fujun

    2015-07-01

    To evaluate the role of low-dose-rate interstitial brachytherapy using trans-bronchoscope 125 I radioactive seeds implantation in patients with pulmonary atelectasis induced by lung cancer, in terms of feasibility, safety, quality of life (QOL), and survival time. Between April 2008 and June 2011, 15 patients from two medical institutions that had obstructive pulmonary atelectasis caused by inoperable lung cancer were assigned to receive 125 I implantation endoluminal brachytherapy by bronchoscopy. Subsequent to the implantation of 125 I seeds, the outcomes were measured in terms of procedure success rate, reopening of atelectasis, complications associated with the procedure, Karnofsky performance status (KPS) scores and survival time. The surgical procedure was successfully performed in all 15 patients. No procedure-associated mortality occurred and the complications were mild and considered acceptable. Irritable cough and temporary increase of hemoptysis occurred in 11 (73.3%) and 10 (66.7%) patients respectively, and were the most common complications. The pulmonary atelectasis reopening rate subsequent to the procedure was 86.7, 76.9, 80.0, 75.0 and 50.0% at 2, 6, 12, 18 and 24 months, respectively. The KPS score significantly improved following the implantation of 125 I seeds and the duration of improvement ranged between 3 and 27 months. The median and mean survival times were 15.6 and 16 months, respectively. Actuarial survival rates at 6, 12 and 24 months after the procedure were 86.7, 66.7 and 13.3%, respectively. In patients with advanced lung cancer and those presenting with obstructive pulmonary atelectasis, treatment with intraluminal implantation of 125 I seeds is a safe and effective therapy option with easy accessibility.

  3. Trans-bronchoscopy with implantation of 125I radioactive seeds in patients with pulmonary atelectasis induced by lung cancer

    PubMed Central

    LU, MINGJIAN; PU, DELI; ZHANG, WEIDONG; LIAO, JIANGRONG; ZHANG, TAO; YANG, GUANG; LIU, ZHENYIN; SINGH, SRISTI; GAO, FEI; ZHANG, FUJUN

    2015-01-01

    To evaluate the role of low-dose-rate interstitial brachytherapy using trans-bronchoscope 125I radioactive seeds implantation in patients with pulmonary atelectasis induced by lung cancer, in terms of feasibility, safety, quality of life (QOL), and survival time. Between April 2008 and June 2011, 15 patients from two medical institutions that had obstructive pulmonary atelectasis caused by inoperable lung cancer were assigned to receive 125I implantation endoluminal brachytherapy by bronchoscopy. Subsequent to the implantation of 125I seeds, the outcomes were measured in terms of procedure success rate, reopening of atelectasis, complications associated with the procedure, Karnofsky performance status (KPS) scores and survival time. The surgical procedure was successfully performed in all 15 patients. No procedure-associated mortality occurred and the complications were mild and considered acceptable. Irritable cough and temporary increase of hemoptysis occurred in 11 (73.3%) and 10 (66.7%) patients respectively, and were the most common complications. The pulmonary atelectasis reopening rate subsequent to the procedure was 86.7, 76.9, 80.0, 75.0 and 50.0% at 2, 6, 12, 18 and 24 months, respectively. The KPS score significantly improved following the implantation of 125I seeds and the duration of improvement ranged between 3 and 27 months. The median and mean survival times were 15.6 and 16 months, respectively. Actuarial survival rates at 6, 12 and 24 months after the procedure were 86.7, 66.7 and 13.3%, respectively. In patients with advanced lung cancer and those presenting with obstructive pulmonary atelectasis, treatment with intraluminal implantation of 125I seeds is a safe and effective therapy option with easy accessibility. PMID:26171002

  4. CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhongmin, E-mail: wzm0722@hotmail.com; Lu, Jian; Gong, Ju

    2013-04-12

    PurposeThis study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases.MethodsTwenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds.ResultsFollow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantationmore » (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment.ConclusionsCT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.« less

  5. The value of spectral imaging to reduce artefacts in the body after 125 I seed implantation.

    PubMed

    Liu, Jingang; Wang, Wenjuan; Zhao, Xingsheng; Shen, Zhen; Shao, Weiguang; Wang, Xizhen; Li, Lixin; Wang, Bin

    2016-10-01

    To explore the value of gemstone spectral imaging (GSI) and metal artefact reduction sequence (MARs) to reduce the artefacts of metal seeds. Thirty-five patients with 125 I seed implantation in their abdomens underwent GSI CT. Six types of monochromatic images and the corresponding MARs images at 60-110 keV (interval of 10 keV) were reconstructed. The differences in the quality of the images of three imaging methods were subjectively assessed by three radiologists. Length of artefacts, the CT value and noise value of tissue adjacent to 125 I seeds, contrast-to-noise ratio (CNR), and artefact index (AI) were recorded. The differences in subjective scoring were statistically significant (t = 10.87, P < 0.001). Images at 70 keV showed the best CNR (0.84 ± 0.17) of tissues adjacent to 125 I seeds, and received the highest subjective score (2.82 ± 0.18). Images at 80 keV had the lowest AI (70.67 ± 19.17). Images at 110 keV had the shortest artefact lengths. High-density metal artefacts in the MARs spectral images were reduced. The length of metal artefacts in images at 110 keV was shorter than that of the polychromatic images and MARs spectral images (t = 3.35, 3.89, P < 0.05). The difference in CNR between MARs spectral images and polychromatic images, and images at 70 keV was statistically significant (t = 3.57, 4.16, P < 0.01). Gemstone spectral imaging technique can reduce metal artefacts of 125 I seeds effectively in CT images, and improve the quality of images, and improve the display of tissues adjacent to 125 I seeds after implantation. MARs technique cannot reduce the artefacts caused by radioactive seeds effectively. © 2016 The Royal Australian and New Zealand College of Radiologists.

  6. [Application of (125)I seeds combined with biliary stent implantation in the treatment of malignant obstructive jaundice].

    PubMed

    Wang, T; Liu, S; Zheng, Y B; Song, X P; Jiang, W J; Sun, B L; Wang, L G

    2016-03-23

    To study the feasibility and therapeutic effect of the application of (125)I seeds combined with biliary stent implantation on the treatment of malignant obstructive jaundice. Fifty patients with malignant obstructive jaundice treated from September 2010 to February 2013 in Yantai Yuhuangding Hospital were included in this study. Among them, 24 patients received biliary stent implantation combined with (125)I seeds intraluminal brachytherapy as experimental group, and 26 were treated by biliary stent implantation as control group.The total bilirubin, direct bilirubin and tumor markers (CA-199, CA-242, CEA) before and after surgery, the biliary stent patency status was assessed, and the survival time was evaluated. The 24 patients in experimental group were implanted with 30 (125)I seeds successfully in a total of 450 seeds. Jaundice was improved greatly in both groups. The CA-199 and CA-242 after treatment in the experimental group were significantly decreased than that before treatment (P=0.003 and P=0.004). CEA was also decreased, but showed no statistical significance (P>0.05). There were no significant improvement comparing the CA-199, CA-242 and CEA before and 2 months after surgery in the control group (P>0.05). The rate of biliary stent patency was 83.3% (20/24) in the experimental group and 57.7% (15/26) in the control group (P=0.048). The mean biliary stent patency time in the experimental group was 9.84 months (range 1-15.5 months). The mean biliary stent patency time in the control group was 5.57 months (range 0.8-9 months). There was a significant difference between the two groups (P=0.018). The median survival time was 10.2 months in the experimental group and 5.4 months in the control group (P<0.05). (125)I seeds combined with biliary stent implantation can inhibit the proliferation of vascular endothelial cells and the growth of tumor effectively, and can prolong the biliary stent patency time and the survival time obviously for patients with

  7. Novel Silicone-Coated 125I Seeds for the Treatment of Extrahepatic Cholangiocarcinoma

    PubMed Central

    Zhang, Weixing; Cai, Xiaobo; Chen, Dafan; Wan, Xinjian

    2016-01-01

    125I seeds coated with titanium are considered a safe and effective interstitial brachytherapy for tumors, while the cost of 125I seeds is a major problem for the patients implanting lots of seeds. The aim of this paper was to develop a novel silicone coating for 125I seeds with a lower cost. In order to show the radionuclide utilization ratio, the silicone was coated onto the seeds using the electro-spinning method and the radioactivity was evaluated, then the anti-tumor efficacy of silicone 125I seeds was compared with titanium 125I seeds. The seeds were divided into four groups: A (control), B (pure silicone), C (silicone 125I), D (titanium 125I) at 2 Gy or 4 Gy. Their anti-tumour activity and mechanism were assessed in vitro and in vivo using a human extrahepatic cholangiocarcinoma cell line FRH-0201 and tumor-bearing BALB/c nude mice. The silicone 125I seeds showed higher radioactivity; the rate of cell apoptosis in vitro and the histopathology in vivo demonstrated that the silicone 125I seeds shared similar anti-tumor efficacy with the titanium 125I seeds for the treatment of extrahepatic cholangiocarcinoma, while they have a much lower cost. PMID:26840346

  8. A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck.

    PubMed

    Huang, Ming-Wei; Liu, Shu-Ming; Zheng, Lei; Shi, Yan; Zhang, Jie; Li, Yan-Sheng; Yu, Guang-Yan; Zhang, Jian-Guo

    2012-11-01

    To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Before (125)I implants, patients received CT scans based on 0.75mm thickness. And the brachytherapy treatment planning system (BTPS) software was used to make the implantation plan based on the CT images. Mimics software and Geomagic software were used to read the data containing CT images and implantation plan, and to design the individual template. Then the individual template containing the information of needle pathway and face features simultaneously was made through rapid prototyping (RP) technique. All patients received (125)I seeds interstitial implantation under the guide of the individual template and CT. The individual templates were positioned easily and accurately, and were stable. After implants, treatment quality evaluation was made by CT and TPS. The seeds and dosages distribution (D(90),V(100),V(150)) were well meet the treatment requirement. Clinical practice confirms that this approach can facilitate easier and more accurate implantation.

  9. Dosimetric effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chibani, Omar; Williamson, Jeffrey F.; Todor, Dorin

    2005-08-15

    A Monte Carlo study is carried out to quantify the effects of seed anisotropy and interseed attenuation for {sup 103}Pd and {sup 125}I prostate implants. Two idealized and two real prostate implants are considered. Full Monte Carlo simulation (FMCS) of implants (seeds are physically and simultaneously simulated) is compared with isotropic point-source dose-kernel superposition (PSKS) and line-source dose-kernel superposition (LSKS) methods. For clinical pre- and post-procedure implants, the dose to the different structures (prostate, rectum wall, and urethra) is calculated. The discretized volumes of these structures are reconstructed using transrectal ultrasound contours. Local dose differences (PSKS versus FMCS and LSKSmore » versus FMCS) are investigated. The dose contributions from primary versus scattered photons are calculated separately. For {sup 103}Pd, the average absolute total dose difference between FMCS and PSKS can be as high as 7.4% for the idealized model and 6.1% for the clinical preprocedure implant. Similarly, the total dose difference is lower for the case of {sup 125}I: 4.4% for the idealized model and 4.6% for a clinical post-procedure implant. Average absolute dose differences between LSKS and FMCS are less significant for both seed models: 3 to 3.6% for the idealized models and 2.9 to 3.2% for the clinical plans. Dose differences between PSKS and FMCS are due to the absence of both seed anisotropy and interseed attenuation modeling in the PSKS approach. LSKS accounts for seed anisotropy but not for the interseed effect, leading to systematically overestimated dose values in comparison with the more accurate FMCS method. For both idealized and clinical implants the dose from scattered photons represent less than 1/3 of the total dose. For all studied cases, LSKS prostate DVHs overestimate D{sub 90} by 2 to 5% because of the missing interseed attenuation effect. PSKS and LSKS predictions of V{sub 150} and V{sub 200} are overestimated by up

  10. [CT guidance 125I seed implantation for pelvic recurrent rectal cancer assisted by 3D printing individual non-coplanar template].

    PubMed

    Wang, H; Wang, J J; Jiang, Y L; Tian, S Q; Ji, Z; Guo, F X; Sun, H T; Fan, J H; Xu, Y P

    2016-12-20

    Objective: To analyze the difference of dosimetric parameters between pre-plan and post-plan of 125 I radioactive seed implantation assisted by 3D printing individual non-coplanar template (3D printing template) for locally recurrent rectal cancer (LRRC). Methods: From February 2016 to April 2016, a total of 10 patients with locally recurrent rectal cancer received 125 I seeds implantation under CT guidance assisted by 3D printing template in Department of Radiation Oncology, Peking University Third Hospital.Each patient underwent CT simulation, three-dimentional treatment planning pre-implantation, 3D printing template design, radioactive seed implantation assisted by 3D printing template and dosimetric verification post implantation. The median activity of seed was 0.63 mCi (0.58 to 0.7 mCi) (2.15- 2.59×10 7 Bq), and the median number of seeds was 80 (19 to 192). D 90 , D 100 , V 100 , V 150 , CI, EI, HI, D 5cc , D 2cc of bladder and bowel of pre-plan and post-plan were calculated, respectively.Paired t test was used to evaluate the difference of dosimetric parameters between pre-plan and post-plan. Results: The median D 90 of pre-plan and post-plan were 13 761.0 and 12 798.8 cGy, respectively.The median D 100 of pre-plan and post-plan were 5 293.6 and 5 397.9 cGy, respectively.The median V 100 of pre-plan and post-plan were 90.0% and 90.0%, respectively.The median V 150 of pre-plan and post-plan were 63.8% and 62.4%, respectively.The median CI of pre-plan and post-plan were 0.73 and 0.67.The median EI of pre-plan and post-plan were 0.22 and 0.30, respectively. The median HI of pre-plan and post-plan were 0.29 and 0.31.The median bladder D 2cc of pre-plan and post-plan were 3 088.8 and 4 240.4 cGy, respectively.The median bowel D 2cc of pre-plan and post-plan were 7 051.6 and 7 903.9 cGy, respectively. Conclusions: 3D printing template might be helpful for locally recurrent rectal cancer patients who received 125 I radioactive seed implantation assisted by 3D

  11. Clinical investigations on the spinal osteoblastic metastasis treated by combination of percutaneous vertebroplasty and (125)I seeds implantation versus radiotherapy.

    PubMed

    Yang, Zuozhang; Tan, Jing; Zhao, Ruilian; Wang, Jiaping; Sun, Hongpu; Wang, Xiaoxue; Xu, Lei; Jiang, Hua; Zhang, Jinlei

    2013-02-01

    To investigate the clinical efficacy of combining digital subtraction angiography-guided percutaneous vertebroplasty (PVP) and (125)I seeds implantation for the treatment of spinal osteoplastic metastasis. A combination of PVP and (125)I implantation was conducted for 50 patients with spinal osteoplastic metastasis, while the other 50 patients who received regular radiation therapy were used as a comparison. Visual analogue pain scale (VAS) and score of life quality (EORTCQLQ-30) were determined for all the patients. Surgery was successful in 89 spinal segments of vertebral body in 50 patients. Each segment of vertebral body was injected with 1-5 mL (2.8 mL for thoracic and 3.1 mL for lumbar vertebral body on average) of bone cement. Postoperative X-ray and CT examination showed that all the patients in the PVP group achieved spinal stability. During the follow-up examination from 6 months to 5 years, 49 patients (98.0%) had significantly relieved back pain, and only 1 case (2.0%) had no obvious improvement. Postoperative VAS score and Karnofsky performance score (KPS) were significantly different from the preoperative scores (p<0.05); and compared to the regular treatment group, PVP combined (125)I seeds showed much better clinical efficacy (p<0.05). PVP is a minimally invasive treatment with easy operation and less complications. PVP can effectively relieve the pain, stabilize the spine, improve the life quality, and reduce the occurrence of paraplegia in patients with spinal osteoplastic metastasis. Utilization of (125)I seeds with PVP can enhance the clinical efficacy.

  12. Clinical Study on Using 125I Seeds Articles Combined with Biliary Stent Implantation in the Treatment of Malignant Obstructive Jaundice.

    PubMed

    Wang, Tao; Liu, Sheng; Zheng, Yan-Bo; Song, Xue-Peng; Sun, Bo-Lin; Jiang, Wen-Jin; Wang, Li-Gang

    2017-08-01

    Aim: To study the feasibility and curative effect of 125 I seeds articles combined with biliary stent implantation in the treatment of malignant obstructive jaundice. Patients and Methods: Fifty patients with malignant obstructive jaundice were included. Twenty-four were treated by biliary stent implantation combined with intraluminal brachytherapy by 125 I seeds articles as the experimental group, while the remaining 26 were treated by biliary stent implantation only as the control group. The goal of this study was to evaluate total bilirubin, direct bilirubin and tumor markers (cancer antigen (CA)-199, CA-242 and carcinoembryonic antigen (CEA)), as well as biliary stent patency status and survival time before and after surgery. Results: Jaundice improved greatly in both groups. The decreases of CA-199 and CA-242 had statistical significance (p=0.003 and p=0.004) in the experimental group. The ratio of biliary stent patency was 83.3% (20/24) in the experimental group and 57.7% (15/26) in the control group (p=0.048). The biliary stent patency time in the experimental group was 1~15.5 (mean=9.84) months. The biliary stent patency time in the control group was 0.8~9 (mean=5.57) months, which was statistically significant (p=0.018). The median survival time was 10.2 months in the experimental group, while 5.4 months in control group (p<0.05). Conclusion: 125 I seeds articles combined with biliary stent implantation significantly prolongs biliary stent patency time and survival time for patients with malignant obstructive jaundice possibly by inhibiting the proliferation of vascular endothelial cells and the growth of tumor. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  13. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    PubMed

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  14. Prospective study of direct radiation exposure measurements for family members living with patients with prostate (125)I seed implantation: Evidence of radiation safety.

    PubMed

    Hanada, Takashi; Yorozu, Atsunori; Shinya, Yukiko; Kuroiwa, Nobuko; Ohashi, Toshio; Saito, Shiro; Shigematsu, Naoyuki

    2016-01-01

    To broaden the current understanding of radiation exposure and risk and to provide concrete evidence of radiation safety related to (125)I seed implantation. Direct radiation exposure measurements were obtained from dosimeters provided to 25 patients who underwent (125)I seed implantation, along with their family members. The estimated lifetime exposure dose and the precaution time for holding children near the patient's chest were calculated in two study periods. During the first and second study period, the mean estimated lifetime exposure doses were, respectively, 7.61 (range: 0.45, 20.21) mSv and 6.84 (range: 0.41, 19.20) mSv for patients, and 0.19 (range: 0.02, 0.54) mSv and 0.25 (range: 0.04, 1.00) mSv for family members. The mean ratios of first and second period measurements were 1.05 (range: 0.44, 3.18) for patients and 1.82 (range: 0.21, 7.04) for family members. The corresponding absolute differences between first and second period measurements were -0.77 (range: -11.40, 7.63) mSv and 0.06 (range: -0.26, 0.79) mSv, respectively. Assuming a dose limit of 1 mSv, the precaution times for holding a child every day of the first and second periods were 250.9 (range: 71.3, 849.4) min and 275.2 (range: 75.0, 883.4) min, respectively. Assuming a dose limit of 0.5 mSv, the corresponding precaution times were 179.0 (range: 35.6, 811.5) min and 178.9 (range: 37.5, 1131.8) min, respectively. Our study demonstrated low radiation exposures to family members of patients undergoing (125)I prostate implantation. It was clear that (125)I seed implantation did not pose a threat to the safety of family members. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Clinical application of computed tomography-guided (125)I seed interstitial implantation for head and neck cancer patients with unmanageable cervical lymph node metastases.

    PubMed

    Huang, Hai; Xu, Shaonian; Li, Fusheng; Du, Zhenguang; Wang, Liang

    2016-04-27

    To assess clinical application of computed tomography (CT)-guided (125)I seed implantation for patients who cannot endure or unwillingly receive repeated surgery, chemotherapy, or radiotherapy for unmanageable cervical lymph node metastases in head and neck cancer (HNC). Thirty-one consecutive patients received CT-guided (125)I seed implantation between February 2010 and December 2013. To evaluate the clinical efficiency, karnofsky performance score (KPS), numeric rating scale (NRS), and tumor volume at 3-, and 6-month post-implantation were compared with pre-implantation, along with local control rate (LCR), overall survival rate (OSR), and complications at 3, 6 months, 1, and 2 years. The tumor volume was obviously decreased at 3-, and 6-month post-implantation (21.23 ± 8.83 versus 9.19 ± 7.52 cm(2); 21.23 ± 8.83 versus 6.42 ± 9.79 cm(2); P < 0.05) compared with pre-implantation. The NRS was statistically reduced (3.06 ± 1.06 versus 7.77 ± 0.92; 2.39 ± 1.15 versus 7.77 ± 0.92; P < 0.05), while KPS was significantly improved (83.18 ± 5.97 versus 73.60 ± 7.90; 82.86 ± 5.43 versus 73.60 ± 7.90; P < 0.05) postoperatively at 3 and 6 months, respectively. The LCR at 3, 6 months, 1, and 2 years was 96.30, 83.87, 64.51, and 45.16%, respectively. The OSR was 100, 100, 67.74, and 45.16%, respectively. Three cases experienced grade I and two had grade II acute radiation toxicity. CT-guided seed implantation may be feasible and safe for HNC patients whose neck nodes are not manageable by routine strategies with fewer complications, higher LCR, and significant pain relief.

  16. Portal Vein Stenting Combined with Iodine-125 Seeds Endovascular Implantation Followed by Transcatheter Arterial Chemoembolization for Treatment of Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus

    PubMed Central

    Zhou, Tanyang; Zhu, Tongyin; Zhang, Yuelin; Nie, Chunhui; Ai, Jing; Zhou, Guanhui; Zhang, Aibin; Dong, Meng-Jie; Wang, Wei-Lin

    2016-01-01

    Aim was to assess the therapeutic value of portal vein stenting (PVS) combined with iodine-125 seed (125I seed) strand endovascular implantation followed by transcatheter arterial chemoembolization (TACE) for treating patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). This was a retrospective study of 34 patients aged 29–81 years, diagnosed HCC with PVTT, and treated with PVS combined with 125I seed strand endovascular implantation followed by TACE between January 2012 and August 2014. Survival, stent patency, technical success rate, complications related to the procedure, and adverse events were recorded. The technical success rate was 100%. No serious procedure-related adverse event was recorded. The median survival was 147 days. The cumulative survival rates and stent patency rates at 90, 180, and 360 days were 94.1%, 61.8%, and 32.4% and 97.1% (33/34), 76.9% (24/34), and 29.4% (10/34), respectively. PVS combined with 125I seed strand endovascular implantation followed by TACE is feasible for patients with HCC and PVTT. It resulted in appropriate survival and stent patency, with no procedure-related adverse effects. PMID:27999793

  17. I-125 seed calibration using the SeedSelectron® afterloader: a practical solution to fulfill AAPM-ESTRO recommendations

    PubMed Central

    Perez-Calatayud, Jose; Richart, Jose; Guirado, Damián; Pérez-García, Jordi; Rodríguez, Silvia; Santos, Manuel

    2012-01-01

    Purpose SeedSelectron® v1.26b (Nucletron BV, The Netherlands) is an afterloader system used in prostate interstitial permanent brachytherapy with I-125 selectSeed seeds. It contains a diode array to assay all implanted seeds. Only one or two seeds can be extracted during the surgical procedure and assayed using a well chamber to check the manufacturer air-kerma strength (SK) and to calibrate the diode array. Therefore, it is not feasible to assay 5–10% seeds as required by the AAPM-ESTRO. In this study, we present a practical solution of the SeedSelectron® users to fulfill the AAPM- ESTRO recommendations. Material and methods The method is based on: a) the SourceCheck® well ionization chamber (PTW, Germany) provided with a PTW insert; b) n = 10 selectSeed from the same batch and class as the seeds for the implant; c) the Nucletron insert to accommodate the n = 10 seeds on the SourceCheck® and to measure their averaged SK. Results for 56 implants have been studied comparing the SK value from the manufacturer with the one obtained with the n = 10 seeds using the Nucletron insert prior to the implant and with the SK of just one seed measured with the PTW insert during the implant. Results We are faced with SK deviation for individual seeds up to 7.8%. However, in the majority of cases SK is in agreement with the manufacturer value. With the method proposed using the Nucletron insert, the large deviations of SK are reduced and for 56 implants studied no deviation outside the range of the class were found. Conclusions The new Nucletron insert and the proposed procedure allow to evaluate the SK of the n = 10 seeds prior to the implant, fulfilling the AAPM-ESTRO recommendations. It has been adopted by Nucletron to be extended to seedSelectron® users under request. PMID:23346136

  18. SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, D; Braunstein, S; Sneed, P

    Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkagemore » rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds

  19. On the use of Kodak CR film for quality assurance of needle loading in I-125 seed prostate brachytherapy.

    PubMed

    Fog, L S; Nicholls, R; van Doom, T

    2007-09-01

    Low dose rate brachytherapy using implanted I-125 seeds as a monotherapy for prostate cancer is now in use in many hospitals. In contrast to fractionated brachytherapy treatments, where the effect of incorrect positioning of the source in one treatment fraction can be diminished by correcting the position in subsequent fractions, the I-125 seed implant is permanent, making correct positioning of the seeds in the prostate essential. The seeds are inserted into the prostate using needles. Correct configuration of seeds in the needles is essential in order to deliver the planned treatment. A comparison of an autoradiograph obtained by exposing film to the seed-loaded needles with the patient treatment plan is a valuable quality assurance tool. However, the time required to sufficiently expose Kodak XOMAT V film, currently used in this department is significant. This technical note presents the use of Kodak CR film for acquisition of the radiograph. The digital radiograph can be acquired significantly faster, has superior signal-to-noise ratio and contrast and has the usual benefits of digital film, e.g. a processing time which is shorter than that required for non-digital film, the possibility of image manipulation, possibility of paper printing and electronic storage.

  20. Three-dimensional verification of ¹²⁵I seed stability after permanent implantation in the parotid gland and periparotid region.

    PubMed

    Fan, Yi; Huang, Ming-Wei; Zheng, Lei; Zhao, Yi-Jiao; Zhang, Jian-Guo

    2015-11-24

    To evaluate seed stability after permanent implantation in the parotid gland and periparotid region via a three-dimensional reconstruction of CT data. Fifteen patients treated from June 2008 to June 2012 at Peking University School and Hospital of Stomatology for parotid gland tumors with postoperative adjunctive (125)I interstitial brachytherapy were retrospectively reviewed in this study. Serial CT data were obtained during follow-up. Mimics and Geomagic Studio software were used for seed reconstruction and stability analysis, respectively. Seed loss and/or migration outside of the treated area were absent in all patients during follow-up (23-71 months). Total seed cluster volume was maximized on day 1 post-implantation due to edema and decreased significantly by an average of 13.5 % (SD = 9.80 %; 95 % CI, 6.82-17.68 %) during the first two months and an average of 4.5 % (SD = 3.60 %; 95 % CI, 2.29-6.29 %) during the next four months. Volume stabilized over the subsequent six months. (125)I seed number and location were stable with a general volumetric shrinkage tendency in the parotid gland and periparotid region. Three-dimensional seed reconstruction of CT images is feasible for visualization and verification of implanted seeds in parotid brachytherapy.

  1. Lessons Learned from Autopsying an Unidentified Body with Iodine-125 Seeds Implanted for Prostate Brachytherapy.

    PubMed

    Idota, Nozomi; Nakamura, Mami; Masui, Koji; Kakiuchi, Yasuhiro; Yamada, Kei; Ikegaya, Hiroshi

    2017-03-01

    We report here lessons learned from an autopsy case involving radioactive materials. We performed an autopsy of an unidentified mummified man with no available medical history whom from imaging findings we suspected had received radioactive seed implants for prostate brachytherapy. We returned the excised prostate and seeds to the body. A few days later, the body was identified by DNA matching and cremated. According to the man's medical record, he had undergone iodine-125 seeds implantation for prostate cancer 11 months earlier. We should have removed the radioactive seeds from the body to prevent radiation exposure to the bereaved family and/or environmental pollution due to cremation. Surprisingly, one seed was found in the stored prostate specimen. Forensic experts should be cognizant of the risk of both radiation exposure in the autopsy room and environmental pollution. We must remain abreast of the latest advances in medicine. © 2016 American Academy of Forensic Sciences.

  2. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.

    PubMed

    Chiu-Tsao, Sou-Tung; Medich, David; Munro, John

    2008-08-01

    Radiochromic film dosimetry has been extensively used for intravascular brachytherapy applications for near field within 1 cm from the sources. With the recent introduction of new model of radiochromic films, GAFCHROMIC EBT, with higher sensitivity than earlier models, it is promising to extend the distances out to 5 cm for low dose rate (LDR) source dosimetry. In this study, the use of new model GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water was evaluated for radial distances from 0.06 cm out to 5 cm. A multiple film technique was employed for four 125I seeds (Implant Sciences model 3500) with NIST traceable air kerma strengths. Each experimental film was positioned in contact with a 125I seed in a Solid Water phantom. The products of the air kerma strength and exposure time ranged from 8 to 3158 U-h, with the initial air kerma strength of 6 U in a series of 25 experiments. A set of 25 calibration films each was sequentially exposed to one 125I seed at about 0.58 cm distance for doses from 0.1 to 33 Gy. A CCD camera based microdensitometer, with interchangeable green (520 nm) and red (665 nm) light boxes, was used to scan all the films with 0.2 mm pixel resolution. The dose to each 125I calibration film center was calculated using the air kerma strength of the seed (incorporating decay), exposure time, distance from seed center to film center, and TG43U1S1 recommended dosimetric parameters. Based on the established calibration curve, dose conversion from net optical density was achieved for each light source. The dose rate constant was determined as 0.991 cGy U(-1)h(-1) (+/-6.9%) and 1.014 cGy U(-1)h(-1) (+/-6.8%) from films scanned using green and red light sources, respectively. The difference between these two values was within the uncertainty of the measurement. Radial dose function and 2D anisotropy function were also determined. The results obtained using the two light sources corroborated each other. We found good agreement with the TG43U1S1

  3. Salvage low-dose-rate 125I partial prostate brachytherapy after dose-escalated external beam radiotherapy

    PubMed Central

    Chang, Lynn

    2014-01-01

    Purpose To report outcomes on 5 patients treated with salvage partial low-dose-rate (LDR) 125-iodine (125I) permanent prostate seed brachytherapy (BT) for biopsy-proven locally persistent prostate cancer, following failure of dose-escalated external beam radiotherapy (EBRT). Material and methods A retrospective review of the Fox Chase Cancer Center prostate cancer database identified five patients treated with salvage partial LDR 125I seed implant for locally persistent disease following dose-escalated EBRT to 76-84 Gy in 2 Gy per fraction equivalent. All patients had post-EBRT biopsies confirming unilateral locally persistent prostate cancer. Pre-treatment, EBRT and BT details, as well as post-treatment characteristics were documented and assessed. Results The median follow-up post-implant was 41 months. All five patients exhibited low acute genitourinary and gastrointestinal toxicities. Increased erectile dysfunction was noted in three patients. There were no biochemical failures following salvage LDR 125I seed BT to date, with a median post-salvage PSA of 0.4 ng/mL. Conclusions In carefully selected patients with local persistence of disease, partial LDR 125I permanent prostate seed implant appears to be a feasible option for salvage local therapy with an acceptable toxicity profile. Further study is needed to determine long-term results of this approach. PMID:25337135

  4. Relative biologic effectiveness in terms of tumor response of {sup 125}I implants compared with {sup 60}Co gamma rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehnert, Shirley; Reniers, Brigitte; Verhaegen, Frank

    2005-09-01

    Purpose: To measure the relative biologic effectiveness (RBE) for {sup 125}I seeds compared with external beam radiotherapy using a clinically relevant in vivo system. Methods and Materials: Photon emission from a detailed source model was simulated using the Monte Carlo code MCNP4C, sampling from a {sup 125}I spectrum. The mouse RIF-1 tumor was treated with either temporary implant of an {sup 125}I seed or with {sup 60}Co gamma rays. The tumors were always the same size at the initiation of treatment, and the endpoint was growth inhibition. Results: The dose-response curve for both modalities was close to linear and wasmore » independent of the initial {sup 125}I activity (dose rate) for the range investigated. Calculation of the RBE for tumor response requires assigning a unique value for the tumor dose that is not homogenous but depends on the distance from the {sup 125}I source. Because tumor regrowth will depend on the subpopulation of cells that have the greatest probability of survival (i.e., those at the greatest distance from the {sup 125}I source), one approach is to use the dose to this population. On this basis, the RBE for {sup 125}I compared with {sup 60}Co gamma rays is 1.5. If the {sup 125}I dose is computed as the average dose to the tumor, corrected for the dose that is wasted as overkill in the cell population closest to the center of the {sup 125}I seed, the RBE is 1.4. Conclusion: The result, an RBE of 1.4-1.5 is similar to findings obtained by other methods, supporting the validity of this approach to derive an RBE with validity in a clinical context.« less

  5. DTI and pathological changes in a rabbit model of radiation injury to the spinal cord after 125I radioactive seed implantation

    PubMed Central

    Cao, Xia; Fang, Le; Cui, Chuan-yu; Gao, Shi; Wang, Tian-wei

    2018-01-01

    Excessive radiation exposure may lead to edema of the spinal cord and deterioration of the nervous system. Magnetic resonance imaging can be used to judge and assess the extent of edema and to evaluate pathological changes and thus may be used for the evaluation of spinal cord injuries caused by radiation therapy. Radioactive 125I seeds to irradiate 90% of the spinal cord tissue at doses of 40–100 Gy (D90) were implanted in rabbits at T10 to induce radiation injury, and we evaluated their safety for use in the spinal cord. Diffusion tensor imaging showed that with increased D90, the apparent diffusion coefficient and fractional anisotropy values were increased. Moreover, pathological damage of neurons and microvessels in the gray matter and white matter was aggravated. At 2 months after implantation, obvious pathological injury was visible in the spinal cords of each group. Magnetic resonance diffusion tensor imaging revealed the radiation injury to the spinal cord, and we quantified the degree of spinal cord injury through apparent diffusion coefficient and fractional anisotropy. PMID:29623940

  6. Continuous Low-dose-rate Irradiation of Iodine-125 Seeds Inhibiting Perineural Invasion in Pancreatic Cancer.

    PubMed

    Lu, Zheng; Dong, Teng-Hui; Si, Pei-Ren; Shen, Wei; Bi, Yi-Liang; Min, Min; Chen, Xin; Liu, Yan

    2016-10-20

    Perineural invasion (PNI) is a histopathological characteristic of pancreatic cancer (PanCa). The aim of this study was to observe the treatment effect of continuous low-dose-rate (CLDR) irradiation to PNI and assess the PNI-related pain relief caused by iodine-125 ( 125 I) seed implantation. The in vitro PNI model established by co-culture with dorsal root ganglion (DRG) and cancer cells was interfered under 2 and 4 Gy of 125 I seeds CLDR irradiation. The orthotopic models of PNI were established, and 125 I seeds were implanted in tumor. The PNI-related molecules were analyzed. In 30 patients with panCa, the pain relief was assessed using a visual analog scale (VAS). Pain intensity was measured before and 1 week, 2 weeks, and 1, 3, and 6 months after 125 I seed implantation. The co-culture of DRG and PanCa cells could promote the growth of PanCa cells and DRG neurites. In co-culture groups, the increased number of DRG neurites and pancreatic cells in radiation group was significantly less. In orthotopic models, the PNI-positive rate in radiation and control group was 3/11 and 7/11; meanwhile, the degrees of PNI between radiation and control groups was significant difference (P < 0.05). At week 2, the mean VAS pain score in patients decreased by 50% and significantly improved than the score at baseline (P < 0.05). The pain scores were lower in all patients, and the pain-relieving effect was retained about 3 months. The CLDR irradiation could inhibit PNI of PanCa with the value of further study. The CLDR irradiation could do great favor in preventing local recurrence and alleviating pain.

  7. Intraoperative 3D Navigation for Single or Multiple 125I-Seed Localization in Breast-Preserving Cancer Surgery.

    PubMed

    Pouw, Bas; de Wit-van der Veen, Linda J; van Duijnhoven, Frederieke; Rutgers, Emiel J Th; Stokkel, Marcel P M; Valdés Olmos, Renato A; Vrancken Peeters, Marie-Jeanne T F D

    2016-05-01

    Mammographic screening has led to the identification of more women with nonpalpable breast cancer, many of them to be treated with breast-preserving surgery. To accomplish radical tumor excision, adequate localization techniques such as radioactive seed localization (RSL) are required. For RSL, a radioactive I-seed is implanted central in the tumor to enable intraoperative localization using a γ-probe. In case of extensive tumor or multifocal carcinoma, multiple I-seeds can be used to delineate the involved area. Preoperative imaging is performed different from surgical positioning; therefore, exact I-seed depth remains unknown during surgery. Twenty patients (mean age, 56.8 years) with 25 implanted I-seeds scheduled for RSL were included. Sixteen patients had 1 I-seed implanted in the primary lesion, 3 patients had 2 I-seeds, and 1 patient had 3 I-seeds. Freehand SPECT localized I-seeds by measuring γ-counts from different directions, all registered by an optical tracking system. A reconstruction and visualization algorithm enabled 3-dimensional (3D) navigation toward the I-seeds. Freehand SPECT visualized all I-seeds in primary tumors and provided preincision depth information. The deviation, mean (SD), between the freehand SPECT depth and the surgical depth estimation was 1.9 (2.1) mm (range, 0-7 mm). Three-dimensional freehand SPECT was especially useful identifying multiple implanted I-seeds because the conventional γ-probe has more difficulty discriminating I-seeds transcutaneous. Freehand SPECT with 3D navigation is a valuable tool in RSL for both single and multiple implanted I-seeds in breast-preserving cancer surgery. Freehand SPECT provides continuous updating 3D imaging with information about depth and location of the I-seeds contributing to adequate excision of nonpalpable breast cancer.

  8. SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, X; Rahimian, J; Goy, B

    Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images.more » Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using

  9. An in vitro verification of strength estimation for moving an 125I source during implantation in brachytherapy.

    PubMed

    Tanaka, Kenichi; Kajimoto, Tsuyoshi; Hayashi, Takahiro; Asanuma, Osamu; Hori, Masakazu; Kamo, Ken-Ichi; Sumida, Iori; Takahashi, Yutaka; Tateoka, Kunihiko; Bengua, Gerard; Sakata, Koh-Ichi; Endo, Satoru

    2018-04-11

    This study aims to demonstrate the feasibility of a method for estimating the strength of a moving brachytherapy source during implantation in a patient. Experiments were performed under the same conditions as in the actual treatment, except for one point that the source was not implanted into a patient. The brachytherapy source selected for this study was 125I with an air kerma strength of 0.332 U (μGym2h-1), and the detector used was a plastic scintillator with dimensions of 10 cm × 5 cm × 5 cm. A calibration factor to convert the counting rate of the detector to the source strength was measured and then the accuracy of the proposed method was investigated for a manually driven source. The accuracy was found to be under 10% when the shielding effect of additional needles for implantation at other positions was corrected, and about 30% when the shielding was not corrected. Even without shielding correction, the proposed method can detect dead/dropped source, implantation of a source with the wrong strength, and a mistake in the number of the sources implanted. Furthermore, when the correction was applied, the achieved accuracy came close to within 7% required to find the Oncoseed 6711 (125I seed with unintended strength among the commercially supplied values of 0.392, 0.462 and 0.533 U).

  10. The direct biologic effects of radioactive 125I seeds on pancreatic cancer cells PANC-1, at continuous low-dose rates.

    PubMed

    Wang, Jidong; Wang, Junjie; Liao, Anyan; Zhuang, Hongqing; Zhao, Yong

    2009-08-01

    The relative biologic effectiveness of model 6711 125I seeds (Ningbo Junan Pharmaceutical Technology Company,Ningbo, China) and their effects on growth, cell cycle, and apoptosis in human pancreatic cancer cell line PANC-1 were examined in the present study. PANC-1 cells were exposed to the absorbed doses of 1, 2, 4, 6, 8, and 10 Gyeither with 125I seeds (initial dose rate, 2.59 cGy=h) or with 60Co g-ray irradiation (dose rate, 221 cGy=min),respectively. Significantly greater numbers of apoptotic PANC-1 cells were detected following the continuouslow-dose-rate (CLDR) irradiation of 125I seeds, compared with cells irradiated with identical doses of 60Co g-ray. The D(0) for 60Co g-ray and 125I seed irradiation were 2.30 and 1.66, respectively. The survival fraction after 125Iseed irradiation was significantly lower than that of 60Co g-ray, with a relative biologic effectiveness of 1.39.PANC-1 cells were dose dependently arrested in the S-phase by 60Co g-rays and in the G2=M phase by 125I seeds,24 hour after irradiation. CLDR irradiation by 125I seeds was more effective in inducing cell apoptosis in PANC-1cells than acute high-dose-rate 60Co g irradiation. Interestingly, CLDR irradiation by 125I seeds can cause PANC-1cell-cycle arrest at the G2=M phase and induce apoptosis, which may be an important mechanism underlying 125Iseed-induced PANC-1 cell inhibition.

  11. Biological effects of low-dose-rate irradiation of pancreatic carcinoma cells in vitro using 125I seeds

    PubMed Central

    Wang, Zhong-Min; Lu, Jian; Zhang, Li-Yun; Lin, Xiao-Zhu; Chen, Ke-Min; Chen, Zhi-Jin; Liu, Fen-Ju; Yan, Fu-Hua; Teng, Gao-Jun; Mao, Ai-Wu

    2015-01-01

    AIM: To determine the mechanism of the radiation-induced biological effects of 125I seeds on pancreatic carcinoma cells in vitro. METHODS: SW1990 and PANC-1 pancreatic cancer cell lines were cultured in DMEM in a suitable environment. Gray’s model of iodine-125 (125I) seed irradiation was used. In vitro, exponential phase SW1990, and PANC-1 cells were exposed to 0, 2, 4, 6, and 8 Gy using 125I radioactive seeds, with an initial dose rate of 12.13 cGy/h. A clonogenic survival experiment was performed to observe the ability of the cells to maintain their clonogenic capacity and to form colonies. Cell-cycle and apoptosis analyses were conducted to detect the apoptosis percentage in the SW1990 and PANC-1 cells. DNA synthesis was measured via a tritiated thymidine (3H-TdR) incorporation experiment. After continuous low-dose-rate irradiation with 125I radioactive seeds, the survival fractions at 2 Gy (SF2), percentage apoptosis, and cell cycle phases of the SW1990 and PANC-1 pancreatic cancer cell lines were calculated and compared. RESULTS: The survival fractions of the PANC-1 and SW1990 cells irradiated with 125I seeds decreased exponentially as the dose increased. No significant difference in SF2 was observed between SW1990 and PANC-1 cells (0.766 ± 0.063 vs 0.729 ± 0.045, P < 0.05). The 125I seeds induced a higher percentage of apoptosis than that observed in the control in both the SW1990 and PANC-1 cells. The rate of apoptosis increased with increasing radiation dosage. The percentage of apoptosis was slightly higher in the SW1990 cells than in the PANC-1 cells. Dose-dependent G2/M cell-cycle arrest was observed after 125I seed irradiation, with a peak value at 6 Gy. As the dose increased, the percentage of G2/M cell cycle arrest increased in both cell lines, whereas the rate of DNA incorporation decreased. In the 3H-TdR incorporation experiment, the dosimetry results of both the SW1990 and PANC-1 cells decreased as the radiation dose increased, with a minimum

  12. TPS-guided interstitial Iodine-125 implantation in patients with oral cavity and maxillofacial carcinomas.

    PubMed

    Meng, J; Zhang, J; Zhuang, Q-W; Wang, X; Li, Z-P; Gu, Q-P

    2014-10-01

    To investigate the efficacy as well as the complications involved in the use of interstitial Iodine-125 implantation for the treatment of oral cavity and maxillofacial carcinomas. Fifteen patients with oral cavity and maxillofacial carcinomas received treatment planning system (TPS)-guided interstitial Iodine-125 implantation. The apparent activity per particle ranged from 0.6 mCi (2.22MBq) to 0.7 mCi (2.59MBq). The matched peripheral dose delivered by radioactive seeds ranged from 90 to 120 Gy. The efficacy of the treatment and the postoperative complications were evaluated during follow-up. The seeds were implanted successfully in all 15 patients and median number of seeds implanted was 36.53. CT scans were performed in all patients at 1-6 months postoperatively. During follow-up at 6-27 months, seed migration occurred and a good local tumor control was achieved with an overall response of 86.7%. No severe side effects were observed. TPS-guided interstitial Iodine-125 implantation is an effective and safe procedure with minimal invasiveness for the treatment of oral cavity and maxillofacial carcinomas, and it effectively prevents the recurrence of cancer and short-term lymphatic metastasis.

  13. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watt, E; Spencer, DP; Meyer, T

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empiricalmore » altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup

  14. Impact of target area selection in 125 Iodine seed brachytherapy on locoregional recurrence in patients with non-small cell lung cancer.

    PubMed

    Yan, Wei-Liang; Lv, Jin-Shuang; Guan, Zhi-Yu; Wang, Li-Yang; Yang, Jing-Kui; Liang, Ji-Xiang

    2017-05-01

    Computed tomography (CT)-guided percutaneous implantation of 125 Iodine radioactive seeds requires the precise arrangement of seeds by tumor shape. We tested whether selecting target areas, including subclinical areas around tumors, can influence locoregional recurrence in patients with non-small cell lung cancer (NSCLC). We divided 82 patients with NSCLC into two groups. Target areas in group 1 (n = 40) were defined along tumor margins based on lung-window CT. Target areas in group 2 (n = 42) were extended by 0.5 cm in all dimensions outside tumor margins. Preoperative plans for both groups were based on a treatment plan system, which guided 125 I seed implantation. Six months later, patients underwent chest CT to evaluate treatment efficacy (per Response Evaluation Criteria in Solid Tumors version 1). We compared locoregional recurrences between the groups after a year of follow-up. We then used the treatment plan system to extend target areas for group 1 patients by 0.5 cm (defined as group 3 data) and compared these hypothetical group 3 planned seeds with the actual seed numbers used in group 1 patients. All patients successfully underwent implantation; none died during the follow-up period. Recurrence was significantly lower in group 2 than in group 1 ( P  < 0.05). Group 1 patients and group 3 data significantly differed in seed numbers ( P  < 0.01). Our results imply that extending the implantation area for 125 I seeds can decrease recurrence risk by eradicating cancerous lymph-duct blockades within the extended areas. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  15. Treatment-related symptoms during the first year following transperineal [sup 125]I prostate implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleinberg, L.; Wallner, K.; Roy, J.

    The purpose was to summarize the urinary, rectal, and sexual symptoms occurring during the first 12 months following [sup 125]I prostatic implantation. Thirty-one patients with Stage T[sub 1] or T[sub 2] prostatic carcinoma were evaluate for morbidity following computed tomography-guided transperineal [sup 125]I implants from 1988 to 1991. The median total activity used was 47 mCi (range 35-37 mCi). Toxicity was evaluated using a modification of the Radiation Therapy Oncology Group grading system. Nocturia was the most common treatment-related symptom, reported by 80% of patients within 2 months after implantation, and persisted at 12 months in 45% of the patients.more » Mild dysuria developed in 48% of patients within 2 months of implantation; two patients needed analgesics for their dysuria. Terazosin hydrochloride (2-10 mg qd) provided subjective improvement of urinary symptoms in seven of eight patients in whom it was tried. Rectal urgency, soft stools, and increased frequency of bowel movements was reported by 25% of the patients within 1-2 months after implantation. The incidence of assymptomatic rectal bleeding or ulceration occurring at any time after implantation was 47%, but resolved in all patients with expectant treatment. Self-limiting ulceration of the rectal mucosal occurred in 16%, but only one patient developed a prostato-rectal fistula, managed with an ileal conduit. Five of the 18 potent patients experienced discomfort on erection or ejaculation, beginning within several weeks of their implant. The discomfort resolved within 6 months in three of the patients, but persisted for 18 and 24 months in the other two. [sup 125]I implantation, as performed in this series, is generally associated with only mild-moderate genitourinary and rectal symptoms that may persist 6 months or more after implantation. 16 refs., 6 figs., 2 tabs.« less

  16. Repeated iodine-125 seed implantations combined with external beam radiotherapy for the treatment of locally recurrent or metastatic stage III/IV non-small cell lung cancer: a retrospective study.

    PubMed

    Li, Wei; Dan, Gang; Jiang, Jianqing; Zheng, Yifeng; Zheng, Xiushan; Deng, Dan

    2016-09-13

    Recurrent or metastatic lung cancer is difficult to manage. This retrospective study aimed to assess the efficacy of repeated iodine-125 seed implantations combined with external beam radiotherapy (EBRT) for locally recurrent or metastatic stage-III/IV non-small cell lung cancer (NSCLC). Eighteen previously treated stage-III/IV NSCLC patients with local or metastatic recurrences underwent 1-to-3 iodine-125 implantations. Six of these patients received palliative EBRT and six patients received combined chemotherapy using gemcitabine and cisplatin. Near-term treatment efficacy was evaluated 3 months after seed implantation by comparing changes in tumor size on computed tomography images; the evaluated outcomes were complete response, partial response, stable disease, and local tumor control rate. Long-term efficacy was assessed based on 1- and 2-year survival rates. Patients were followed up for 6 to 50 months. The overall (i.e., complete + partial) response rate was 87.4 %. The local control rates after the first, second, and third years were 94.1, 58.8 and 41.2 %, respectively. The results of this study demonstrated that repeated implantation of radioactive particles combined with EBRT is a safe treatment that effectively controlled local recurrence and metastasis of stage III/IV NSCLC.

  17. Characterization of the PTW SourceCheck ionization chamber with the Valencia lodgment for (125)I seed verification.

    PubMed

    Tornero-López, Ana M; Torres Del Río, Julia; Ruiz, Carmen; Perez-Calatayud, Jose; Guirado, Damián; Lallena, Antonio M

    2015-12-01

    In brachytherapy using (125)I seed implants, a verification of the air kerma strength of the sources used is required. Typically, between 40 and 100 seeds are implanted. Checking all of them is unaffordable, especially when seeds are disposed in sterile cartridges. Recently, a new procedure allowing the accomplishment of the international recommendations has been proposed for the seedSelectron system of Elekta Brachytherapy. In this procedure, the SourceCheck ionization chamber is used with a special lodgment (Valencia lodgment) that allows to measure up to 10 seeds simultaneously. In this work we analyze this procedure, showing the feasibility of the approximations required for its application, as well as the effect of the additional dependence with the air density that shows the chamber model used. Uncertainty calculations and the verification of the approximation needed to obtain a calibration factor for the Valencia lodgment are carried out. The results of the present work show that the chamber dependence with the air density is the same whether the Valencia lodgment is used or not. On the contrary, the chamber response profile is influenced by the presence of the lodgment. The determination of this profile requires various measurements due to the nonnegligible variability found between different experiments. If it is considered, the uncertainty in the determination of the air-kerma strength increases from 0.5% to 1%. Otherwise, a systematic additional uncertainty of 1% would occur. This could be relevant for the comparison between user and manufacturer measurements that is mandatory in the case studied here. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

    PubMed

    Pantelis, Evaggelos; Papagiannis, Panagiotis; Anagnostopoulos, Giorgos; Baltas, Dimos

    2013-12-01

    To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. Monte Carlo simulations were performed using the MCNP5 v.1.6 general purpose code. The model of the new source was prepared from information provided by the manufacturer and verified by imaging a sample of ten non-radioactive sources. Corresponding simulations were also performed for the 6711 (125)I brachytherapy source, using updated geometric information presented recently in the literature. The uncertainty of the dose distribution around the new source, as well as the dosimetric quantities derived from it according to the Task Group 43 formalism, were determined from the standard error of the mean of simulations for a sample of fifty source models. These source models were prepared by randomly selecting values of geometric parameters from uniform distributions defined by manufacturer stated tolerances. Results are presented in the form of the quantities defined in the update of the Task Group 43 report, as well as a relative dose rate table in Cartesian coordinates. The dose rate distribution of the new source is comparable to that of sources of similar design (IsoSeed I25.S17, Oncoseed 6711, SelectSeed 130.002, Advantage IAI-125A, I-Seed AgX100, Thinseed 9011). Noticeable differences were observed only for the IsoSeed I25.S06 and Best 2301 sources.

  19. In vivo dosimetry using a linear Mosfet-array dosimeter to determine the urethra dose in 125I permanent prostate implants.

    PubMed

    Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe

    2009-01-01

    In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

  20. Dosimetry for 131Cs and 125I seeds in solid water phantom using radiochromic EBT film.

    PubMed

    Chiu-Tsao, Sou-Tung; Napoli, John J; Davis, Stephen D; Hanley, Joseph; Rivard, Mark J

    2014-09-01

    To measure the 2D dose distributions with submillimeter resolution for (131)Cs (model CS-1 Rev2) and (125)I (model 6711) seeds in a Solid Water phantom using radiochromic EBT film for radial distances from 0.06cm to 5cm. To determine the TG-43 dosimetry parameters in water by applying Solid Water to liquid water correction factors generated from Monte Carlo simulations. Each film piece was positioned horizontally above and in close contact with a (131)Cs or (125)I seed oriented horizontally in a machined groove at the center of a Solid Water phantom, one film at a time. A total of 74 and 50 films were exposed to the (131)Cs and (125)I seeds, respectively. Different film sizes were utilized to gather data in different distance ranges. The exposure time varied according to the seed air-kerma strength and film size in order to deliver doses in the range covered by the film calibration curve. Small films were exposed for shorter times to assess the near field, while larger films were exposed for longer times in order to assess the far field. For calibration, films were exposed to either 40kV (M40) or 50kV (M50) x-rays in air at 100.0cm SSD with doses ranging from 0.2Gy to 40Gy. All experimental, calibration and background films were scanned at a 0.02cmpixel resolution using a CCD camera-based microdensitometer with a green light source. Data acquisition and scanner uniformity correction were achieved with Microd3 software. Data analysis was performed using ImageJ, FV, IDL and Excel software packages. 2D dose distributions were based on the calibration curve established for 50kV x-rays. The Solid Water to liquid water medium correction was calculated using the MCNP5 Monte Carlo code. Subsequently, the TG-43 dosimetry parameters in liquid water medium were determined. Values for the dose-rate constants using EBT film were 1.069±0.036 and 0.923±0.031cGyU(-1)h(-1) for (131)Cs and (125)I seed, respectively. The corresponding values determined using the Monte Carlo method

  1. Effect of improved TLD dosimetry on the determination of dose rate constants for {sup 125}I and {sup 103}Pd brachytherapy seeds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, M., E-mail: manuel.rodriguez@rmp.uhn.ca; Rogers, D. W. O.

    Purpose: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for {sup 125}I and {sup 103}Pd brachytherapy seeds, to thereby establish revised “measured values” for all seeds and compare the revised values with Monte Carlo and consensus values. Methods: The relative absorbed-dose energy dependence, f{sup rel}, for TLDs and the phantom correction, P{sub phant}, are calculated for {sup 125}I and {sup 103}Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced bymore » calculated (f{sup rel}){sup −1} and P{sub phant} values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, k{sub bq}{sup rel}, is determined. The new P{sub phant} values and relative absorbed-dose sensitivities, S{sub AD}{sup rel}, calculated as the product of (f{sup rel}){sup −1} and (k{sub bq}{sup rel}){sup −1}, are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. Results: In general, f{sup rel} is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among {sup 125}I and {sup 103}Pd seed models and common TLD shapes. P{sub phant} values depend primarily on the isotope used. Deduced (k{sub bq}{sup rel}){sup −1} values are 1.074 ± 0.015 and 1.084 ± 0.026 for {sup 125}I and {sup 103}Pd seeds, respectively. For (1 mm){sup 3} chips, this implies an overall absorbed-dose sensitivity relative to {sup 60}Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for {sup 125}I and {sup 103}Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of P{sub phant} calculated here have much lower statistical uncertainties than literature values, but

  2. Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcu, Loredana G., E-mail: loredana@marcunet.com; Faculty of Science, University of Oradea; School of Chemistry and Physics, University of Adelaide, South Australia

    2013-10-01

    Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methodsmore » was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.« less

  3. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    PubMed

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  4. Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genebes, Caroline, E-mail: genebes.caroline@claudiusregaud.fr; Filleron, Thomas; Graff, Pierre

    2013-11-15

    Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-riskmore » and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes.« less

  5. 125I Brachytherapy in Locally Advanced Nonsmall Cell Lung Cancer After Progression of Concurrent Radiochemotherapy

    PubMed Central

    Xiang, Zhanwang; Li, Guohong; Liu, Zhenyin; Huang, Jinhua; Zhong, Zhihui; Sun, Lin; Li, Chuanxing; Zhang, Funjun

    2015-01-01

    Abstract To investigate the safety and effectiveness of computed tomography (CT)-guided 125I seed implantation for locally advanced nonsmall cell lung cancer (NSCLC) after progression of concurrent radiochemotherapy (CCRT). We reviewed 78 locally advanced NSCLC patients who had each one cycle of first-line CCRT but had progressive disease identified from January 2006 to February 2015 at our institution. A total of 37 patients with 44 lesions received CT-guided percutaneous 125I seed implantation and second-line chemotherapy (group A), while 41 with 41 lesions received second-line chemotherapy (group B). Patients in group A and B received a total of 37 and 41 first cycle of CCRT treatment. The median follow-up was 19 (range 3–36) months. After the second treatment, the total response rate (RR) in tumor response accounted for 63.6% in group A, which was significantly higher than that of group B (41.5%) (P = 0.033). The median progression-free survival time (PFST) was 8.00 ± 1.09 months and 5.00 ± 0.64 months in groups A and B (P = 0.011). The 1-, 2-, and 3-year overall survival (OS) rates for group A were 56.8%, 16.2%, and 2.7%, respectively. For group B, OS rates were 36.6%, 9.8%, and 2.4%, respectively. The median OS time was 14.00 ± 1.82 months and 10.00 ± 1.37 months for groups A and B, respectively (P = 0.059). Similar toxicity reactions were found in both groups. Tumor-related clinical symptoms were significantly reduced and the patients’ quality of life was obviously improved. CT-guided 125I seed implantation proved to be potentially beneficial in treating localized advanced NSCLC; it achieved good local control rates and relieved clinical symptoms without increasing side effects. PMID:26656370

  6. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with {sup 125}I seeds (model I25.S16)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Oezbay, Ismail

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with {sup 125}I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for {sup 125}I seeds (model I25.S16) in COMS eyemore » plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14-20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at {sup 125}I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0

  7. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    PubMed

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  8. Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todor, Dorin A., E-mail: dtodor@mcvh-vcu.edu; Barani, Igor J.; Lin, Peck-Sun

    2011-09-01

    Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants,more » prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level

  9. SU-F-T-39: Comparing Nomograms for Ordering of Palladium-103 Seeds for Dynamic Intraoperative Prostate Seed Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, P; Wang, L; Riegel, A

    Purpose: Several nomograms exist for the purpose of ordering palladium- 103 seeds for permanent prostate seed implants. Excess seeds pose additional radiation safety risks and increase the cost of care. This study compared three seed ordering nomograms with seed counts from dynamic intra-operative PSI to determine (1) the cause of excess seeds and (2) the optimal nomogram for our institution. Methods: Pre-operative and intra-operative clinical data were collected for 100 Gy (n=151) and 125 Gy (n=224) prostate seed implants. The number of implanted seeds which would have given D90=100% was normalized to that criteria and seed strength of 2U. Thismore » was plotted against intra-operative prostate volume and compared to two previously published nomograms and an in-house nomogram. A linear fit was produced and confidence intervals were calculated. The causes of excess seeds were assessed by comparing pre- and intra-operative prostate volumes, variability of D90 around 100%, and variance of seed strength from 2U. Results: Of the 375 total cases, 97.6% had excess seeds. On average, 27.17±12.91% of ordered seeds were wasted. Of this percentage, 6.98±5.47% of excess seeds were due to overestimation of pre-operative prostate volume, 1.10±0.88% were due to D90<100%, 1.17±0.67% were due to seed strength over 2U, and 17.36±7.79% could not be directly attributed to a specific reason. The latter percentage may be due to overestimation of the in-house nomogram. Two of three nomograms substantially overestimated the number of seeds required. The third nomogram underestimated the required seed number for smaller prostate treatment volume. A linear fit to the clinical data was derived and 99.9% confidence intervals were calculated. Conclusion: Over 85% of clinical cases wasted over 15% of ordered seeds. Two of three nomograms overestimated the required number of seeds. The upper 99.9% C.I. of the clinical data may provide a more reasonable nomogram for Pd-103 seed ordering.« less

  10. Moving toward focal therapy in prostate cancer: dual-isotope permanent seed implants as a possible solution.

    PubMed

    Todor, Dorin A; Barani, Igor J; Lin, Peck-Sun; Anscher, Mitchell S

    2011-09-01

    To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Nine plans, using 125I, 103Pd, and 131Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTVi) were delineated along with PTV (prostate+5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTVi were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. The EUBED of PTVi in the setting of primary 125I implant increased 20-66% when 103Pd and 131Cs were used compared with 125I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTVi (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. A novel curvilinear approach for prostate seed implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podder, Tarun K.; Dicker, Adam P.; Hutapea, Parsaoran

    Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90},more » V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the curvilinear

  12. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.

    PubMed

    Furstoss, C; Reniers, B; Bertrand, M J; Poon, E; Carrier, J-F; Keller, B M; Pignol, J P; Beaulieu, L; Verhaegen, F

    2009-05-01

    A Monte Carlo (MC) study was carried out to evaluate the effects of the interseed attenuation and the tissue composition for two models of 125I low dose rate (LDR) brachytherapy seeds (Medi-Physics 6711, IBt InterSource) in a permanent breast implant. The effect of the tissue composition was investigated because the breast localization presents heterogeneities such as glandular and adipose tissue surrounded by air, lungs, and ribs. The absolute MC dose calculations were benchmarked by comparison to the absolute dose obtained from experimental results. Before modeling a clinical case of an implant in heterogeneous breast, the effects of the tissue composition and the interseed attenuation were studied in homogeneous phantoms. To investigate the tissue composition effect, the dose along the transverse axis of the two seed models were calculated and compared in different materials. For each seed model, three seeds sharing the same transverse axis were simulated to evaluate the interseed effect in water as a function of the distance from the seed. A clinical study of a permanent breast 125I implant for a single patient was carried out using four dose calculation techniques: (1) A TG-43 based calculation, (2) a full MC simulation with realistic tissues and seed models, (3) a MC simulation in water and modeled seeds, and (4) a MC simulation without modeling the seed geometry but with realistic tissues. In the latter, a phase space file corresponding to the particles emitted from the external surface of the seed is used at each seed location. The results were compared by calculating the relevant clinical metrics V85, V100, and V200 for this kind of treatment in the target. D90 and D50 were also determined to evaluate the differences in dose and compare the results to the studies published for permanent prostate seed implants in literature. The experimental results are in agreement with the MC absolute doses (within 5% for EBT Gafchromic film and within 7% for TLD-100

  13. New National Air-Kerma-Strength Standards for 125I and 103Pd Brachytherapy Seeds

    PubMed Central

    Seltzer, Stephen M.; Lamperti, Paul J.; Loevinger, Robert; Mitch, Michael G.; Weaver, James T.; Coursey, Bert M.

    2003-01-01

    The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (WAFAC) is specially designed to realize air kerma from a single-seed source emitting photons with energies up to about 40 keV, and is now used to measure the wide variety of seeds used in prostate-cancer therapy that has appeared in the last few years. For the two 125I seed models that have been subject to both the old and new standards, the new standard reduces the air-kerma strength by 10.3 %. This change is mainly due to the removal of the influence on the measurement of the Ti K x rays produced in the source encapsulation, a component with no clinical significance. PMID:27413614

  14. SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamura, K; Araki, F; Ohno, T

    Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photonmore » and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.« less

  15. In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive 125I Seeds

    PubMed Central

    Yao, Li-Hong; Wang, Jun-Jie; Shang, Charles; Jiang, Ping; Lin, Lei; Sun, Hai-Tao; Liu, Lu; Liu, Hao; He, Di; Yang, Rui-Jie

    2017-01-01

    Background: A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths — with different number as well as activities of 125I seeds. Methods: The radiation dosimetry of three representative radioactive stent models was evaluated using a treatment planning system (TPS), thermoluminescent dosimeter (TLD) measurements, and Monte Carlo (MC) simulations. In the process of TPS calculation and TLD measurement, two different water-equivalent phantoms were designed to obtain cumulative radial dose distribution. Calibration procedures using TLD in the designed phantom were also conducted. MC simulations were performed using the Monte Carlo N-Particle eXtended version 2.5 general purpose code to calculate the radioactive stent's three-dimensional dose rate distribution in liquid water. Analysis of covariance was used to examine the factors influencing radial dose distribution of the radioactive stent. Results: The maximum reduction in cumulative radial dose was 26% when the seed activity changed from 0.5 mCi to 0.4 mCi for the same length of radioactive stents. The TLD's dose response in the range of 0–10 mGy irradiation by 137Cs γ-ray was linear: y = 182225x − 6651.9 (R2= 0.99152; y is the irradiation dose in mGy, x is the TLDs’ reading in nC). When TLDs were irradiated by different energy radiation sources to a dose of 1 mGy, reading of TLDs was different. Doses at a distance of 0.1 cm from the three stents’ surface simulated by MC were 79, 93, and 97 Gy. Conclusions: TPS calculation, TLD measurement, and MC simulation were performed and were found to be in good agreement. Although the whole experiment was conducted in water-equivalent phantom, data in our evaluation may provide a theoretical basis for dosimetry for the clinical application. PMID:28469106

  16. CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: The impact of seed size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Andrew K. H.; Basran, Parminder S.; Thomas, Steven D.

    Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds andmore » the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3

  17. Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zauls, A. Jason; Ashenafi, Michael S.; Onicescu, Georgiana

    2011-11-15

    Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method,more » the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.« less

  18. A case-cohort study of recurrent salivary adenoid cystic carcinoma after iodine 125 brachytherapy and resection treatment.

    PubMed

    Li, Bin-bin; Xie, Xiao-Yan; Jia, Sheng-Nan

    2015-02-01

    Recurrent adenoid cystic carcinoma (rAdCC) can be challenging to be treated with brachytherapy, although brachytherapy is safe and effective in treating head and neck cancers. Patients of adenoid cystic carcinoma (AdCC), who underwent resection and iodine 125 ((125)I) radioactive seed implantation, were recruited for this study. Clinical data, surgical details of resection and seed implantation, histologic characteristics, and prognosis were studied. There were 16 rAdCC cases among 140 cases of AdCC treated with brachytherapy and resection. The mean follow-up duration for the recurrent cases was 61 months. The 3-year local control rate of rAdCC was 51.6%, and the overall disease-specific survival rate was 49.4%. Eight patients showed distant metastasis (50%, 8/16). The histologic grades of 10 rAdCCs were upgraded (62.5%, 10/16).Two cases displayed sarcomatous transformation after brachytherapy (1.4%, 2/140). Although the overall local control rate and survival rate were relatively favorable, some rAdCCs with an aggressive phenotype appeared to respond poorly to (125)I seed implantation. Preventive adjuvant chemotherapy should be prescribed for these rAdCCs. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Nationwide Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation (J-POPS): first analysis on survival.

    PubMed

    Ito, Kazuto; Saito, Shiro; Yorozu, Atsunori; Kojima, Shinsuke; Kikuchi, Takashi; Higashide, Satoshi; Aoki, Manabu; Koga, Hirofumi; Satoh, Takefumi; Ohashi, Toshio; Nakamura, Katsumasa; Katayama, Norihisa; Tanaka, Nobumichi; Nakano, Masahiro; Shigematsu, Naoyuki; Dokiya, Takushi; Fukushima, Masanori

    2018-06-22

    Investigating oncological outcomes in patients registered in the Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation (J-POPS) in terms of biochemical relapse-free survival (bRFS) by the Phoenix and the newly developed J-POPS definitions, exploration of predictive factors for bRFS, and preliminary verification of pitfalls of prostate-specific antigen (PSA) failure definitions. Between July 2005 and June 2007, 2316 clinically localized patients underwent permanent seed implantation. The primary endpoint was bRFS. One of the secondary endpoints was overall survival (OS). The median age was 69 and performance status was 0 in 99.1% of participants. The median biologically effective dose (BED) was about 180 Gy 2 . During a median follow-up of 60.0 months, 8.4 and 5.9% had PSA failure by the Phoenix and the J-POPS definitions, respectively. The 5-year bRFSs based on the Phoenix and the J-POPS definitions were 89.1 and 91.6%, respectively. The 5-year OS was 97.3%. According to multivariate analyses, only age affected bRFS based on the Phoenix definition, whereas the risk group and BED independently affected bRFS based on the J-POPS definition. A spontaneous PSA decrease was seen in 91.1% of participants after PSA failure based on the Phoenix definition alone, but in only 22.2% after PSA failure based on the J-POPS definition alone. The world's largest registration study, J-POPS, consisted of patients with longevity, and a highly quality-controlled BED resulted in excellent bRFS and OS. The high likelihood of PSA bounce by the Phoenix definition should be taken into account, especially in younger patients. NCT00534196.

  20. A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an {sup 125}I seed already having AAPM consensus data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aryal, Prakash; Molloy, Janelle A.; Rivard, Mark J., E-mail: mark.j.rivard@gmail.com

    2014-02-15

    Purpose: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A{sup 125}I seed and to propose new standard dosimetry parameters. Methods: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying{sup 125}I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. Results: Varying{sup 125}I coating thickness, coating mass density, photon cross-section library, andmore » photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h{sup −1} U{sup −1}. The dose-rate constant values by Solberg et al. [“Dosimetric parameters of three new solid core {sup 125}I brachytherapy sources,” J. Appl. Clin. Med. Phys. 3, 119–134 (2002)], Meigooni et al. [“Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ {sup 125}I brachytherapy source,” Med. Phys. 29, 2152–2158 (2002)], and Taylor and Rogers [“An EGSnrc Monte Carlo-calculated database of TG-43 parameters,” Med. Phys. 35, 4228–4241 (2008)] for the model IAI-125A seed and Kennedy et al. [“Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source,” Med. Phys. 37, 1681–1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h{sup −1} U{sup −1}), +6.2% (0.98 cGy h{sup −1} U{sup −1}), +0.3% (0.925 cGy h{sup −1} U{sup −1}), and −0.2% (0.921 cGy h{sup −1} U{sup −1}), respectively, in comparison to the proposed

  1. MR and CT image fusion for postimplant analysis in permanent prostate seed implants.

    PubMed

    Polo, Alfredo; Cattani, Federica; Vavassori, Andrea; Origgi, Daniela; Villa, Gaetano; Marsiglia, Hugo; Bellomi, Massimo; Tosi, Giampiero; De Cobelli, Ottavio; Orecchia, Roberto

    2004-12-01

    To compare the outcome of two different image-based postimplant dosimetry methods in permanent seed implantation. Between October 1999 and October 2002, 150 patients with low-risk prostate carcinoma were treated with (125)I and (103)Pd in our institution. A CT-MRI image fusion protocol was used in 21 consecutive patients treated with exclusive brachytherapy. The accuracy and reproducibility of the method was calculated, and then the CT-based dosimetry was compared with the CT-MRI-based dosimetry using the dose-volume histogram (DVH) related parameters recommended by the American Brachytherapy Society and the American Association of Physicists in Medicine. Our method for CT-MRI image fusion was accurate and reproducible (median shift <1 mm). Differences in prostate volume were found, depending on the image modality used. Quality assurance DVH-related parameters strongly depended on the image modality (CT vs. CT-MRI): V(100) = 82% vs. 88%, p < 0.05. D(90) = 96% vs. 115%, p < 0.05. Those results depend on the institutional implant technique and reflect the importance of lowering inter- and intraobserver discrepancies when outlining prostate and organs at risk for postimplant dosimetry. Computed tomography-MRI fused images allow accurate determination of prostate size, significantly improving the dosimetric evaluation based on DVH analysis. This provides a consistent method to judge a prostate seed implant's quality.

  2. Iodine 125 source in interstitial tumor therapy. Clinical and biological considerations.

    PubMed

    Kim, J H; Hilaris, B

    1975-01-01

    Our clinical experience with interstitial tumor therapy is presented in 2 groups of patients: 98 patients with metastatic carcinoma in neck lymph nodes implanted with iodine 125, iridium 192 or radon 222 encapsulated sources, and 105 patients with primary unresectable lung tumors, which were implanted either with radon 222 or iodine 125 seeds. The local tumor control rates with iodine 125, radon 222 and iridium 192 were 78 per cent (38/49), 65 per cent (15/23) and 58 per cent (7/12), while the local complication rates were 17 per cent, 35 per cent and 43 per cent, respectively. An analysis of the tumor control rate as a function of the implanted tumor dose shows that the iodine 125 implants with a delivery of the minimal effective tumor dose of 16,000 rads have a higher therapeutic effect than either radon 222 or iridium 192. The results of the patients with unresectable lung tumors similarly show that the implants with iodine 125 sources are superior to those with radon 222. The advantages could stem from the better spatial dose distribution, and from radiobiologic considerations associated with low dose rates, continous irradiation, and possibly gains in RBE. There present clinical data clearly demonstrate that iodine 125 seeds have a higher therapeutic ratio than radon 222 seeds. There are, in addition, distinct physical advantages making iodine 125 an attractive substitute for radon 222 for the interstitial implantation of malignant tumors.

  3. Combination of Permanent Interstitial 125I-Seed Brachytherapy and Surgery for the Treatment of Large Hepatocellular Carcinoma

    PubMed Central

    Li, Xiaogang; Li, Bo; Yang, Rong; Luo, Kaiyuan

    2017-01-01

    The treatment methods available for large primary hepatocellular carcinomas (diameter >5 cm) are inadequate. Here, we report the successful management of 80 cases of large hepatocellular carcinoma, using a combination of custom-designed permanent interstitial iodine-125 seed brachytherapy and palliative surgery. Patients were enrolled in the study between 2011 and 2014. All patients underwent surgical treatment along with permanent interstitial iodine-125 seed brachytherapy; for the latter, patients received minimum doses covering 90% of the target (D90 s) of iodine-125 seeds ranging from 100 to 160 Gy (median: 110 Gy). All patients received 6 cycles of chemotherapy and were followed up at 6, 12, 24, and 36 months postoperatively. The clinical symptom remission rate was 95.3% (61 of 64). Alanine aminotransferase and aspartate aminotransferase levels decreased to normal in 80% (50 of 60) and 75% of the patients (45 of 60), respectively. The posttreatment alpha-fetoprotein levels decreased by 50% in 80% of the patients (40 of 50). The effective therapy rates were 80% (76 of 95) for 95 tumor nodules (diameters 5-10 cm) and 78.6% (33 of 42) for 42 tumor nodules (diameters >10 cm). The 3-year disease-free survival rate was 66.6%. Palliative surgery plus permanent interstitial iodine-125 seed brachytherapy appears to be a reasonable therapeutic alternative for large hepatocellular carcinoma. PMID:28585493

  4. Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code.

    PubMed

    Bohm, Tim D; DeLuca, Paul M; DeWerd, Larry A

    2003-04-01

    Permanent implantation of low energy (20-40 keV) photon emitting radioactive seeds to treat prostate cancer is an important treatment option for patients. In order to produce accurate implant brachytherapy treatment plans, the dosimetry of a single source must be well characterized. Monte Carlo based transport calculations can be used for source characterization, but must have up to date cross section libraries to produce accurate dosimetry results. This work benchmarks the MCNP code and its photon cross section library for low energy photon brachytherapy applications. In particular, we calculate the emitted photon spectrum, air kerma, depth dose in water, and radial dose function for both 125I and 103Pd based seeds and compare to other published results. Our results show that MCNP's cross section library differs from recent data primarily in the photoelectric cross section for low energies and low atomic number materials. In water, differences as large as 10% in the photoelectric cross section and 6% in the total cross section occur at 125I and 103Pd photon energies. This leads to differences in the dose rate constant of 3% and 5%, and differences as large as 18% and 20% in the radial dose function for the 125I and 103Pd based seeds, respectively. Using a partially updated photon library, calculations of the dose rate constant and radial dose function agree with other published results. Further, the use of the updated photon library allows us to verify air kerma and depth dose in water calculations performed using MCNP's perturbation feature to simulate updated cross sections. We conclude that in order to most effectively use MCNP for low energy photon brachytherapy applications, we must update its cross section library. Following this update, the MCNP code system will be a very effective tool for low energy photon brachytherapy dosimetry applications.

  5. Transarterial chemoembolization plus iodine-125 implantation for hepatocellular carcinoma: a systematic review and meta-analysis.

    PubMed

    Zhu, Ze-Xin; Wang, Xiao-Xue; Yuan, Ke-Fei; Huang, Ji-Wei; Zeng, Yong

    2018-05-17

    Hepatocellular carcinoma (HCC) is the most common malignancy in liver. Transarterial chemoembolization (TACE) is recommended as an effective treatment in advanced HCC patients. Recent studies showed iodine-125 seed (a low-energy radionuclide) can provide long-term local control and increase survival for HCC patients. The aim of the study was to evaluate the outcome of TACE plus iodine-125 seed in comparison with TACE alone for HCC. A comprehensive search of studies among PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted with published date from the earliest to January 10th, 2018. No language restrictions were applied, while only prospective randomized controlled trials (RCTs) or non-randomized controlled trials (non-RCTs) were eligible for a full-text review. The primary outcome was overall survival (OS), response rate (the rate of partial atrophy or complete clearance of the tumor lesion) and adverse events (AEs). The odds ratios (ORs) were combined using either fixed-effects model or random-effects model. All statistical analyses were performed using the Stata 12.0 software. 9 studies were included, involving 894 patients. Among them, 473 patients received combined therapy of TACE plus iodine-125 implantation, compared with 421 patients with TACE alone. Patients receiving combined therapy of TACE plus iodine-125 showed significantly improvement in 1-year OS (OR = 4.47, 95% confidence intervals (CI): 2.97-6.73; P < 0.001), 2-year OS (OR = 4.72, 95% CI: 2.63-8.47; P < 0.001). No significant publication bias was observed in any of the measured outcomes. Based on these findings, TACE plus iodine-125 implantation achieves better clinical efficacy compared with TACE alone in the treatment of HCC. Copyright © 2018. Published by Elsevier Ltd.

  6. SU-E-T-301: Dosimetric Comparison Between Adaptive and Rectilinear Template-Based Prostate Seed Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugar, E Neubauer; Buzurovic, I; O’Farrell, D

    2015-06-15

    Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needlemore » was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.« less

  7. Mature Follow-Up for High-Risk Stage I Non-Small-Cell Lung Carcinoma Treated With Sublobar Resection and Intraoperative Iodine-125 Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colonias, Athanasios, E-mail: acolonia@wpahs.or; Drexel University College of Medicine, Allegheny Campus, Pittsburgh, PA; Betler, James

    2011-01-01

    Purpose: To update the Allegheny General Hospital experience of high-risk Stage I non-small-cell lung cancer patients treated with sublobar resection and intraoperative {sup 125}I Vicryl mesh brachytherapy. Methods and Materials: Between January 5, 1996 and February 19, 2008, 145 patients with Stage I non-small-cell lung cancer who were not lobectomy candidates because of cardiopulmonary compromise underwent sublobar resection and placement of {sup 125}I seeds along the resection line. The {sup 125}I seeds embedded in Vicryl suture were attached with surgical clips to a sheet of Vicryl mesh, inserted over the target area, and prescribed to a 0.5-cm planar margin. Results:more » The mean target area, total activity, number of seeds implanted, and prescribed total dose was 33.3 cm{sup 2} (range, 18.0-100.8), 20.2 mCi (range, 11.1-29.7), 46 (range, 30-100), and 117 Gy (range, 80-180), respectively. The median length of the surgical stay was 6 days (range, 1-111), with a perioperative mortality rate of 3.4%. At a median follow-up of 38.3 months (range, 1-133), 6 patients had developed local recurrence (4.1%), 9 had developed regional failure (6.2%), and 25 had distant failure (17.2%). On multivariate analysis, no patient- or tumor-specific factors or surgical or dosimetric factors were predictive of local recurrence. The overall median survival was 30.5 months with a 3- and 5-year overall survival rate of 65% and 35%, respectively. Conclusion: {sup 125}I brachytherapy for high-risk, Stage I non-small-cell lung cancer after sublobar resection is well tolerated and associated with a low local failure rate.« less

  8. Radioactive iodine-125 implantation for cancer of the prostate.

    PubMed

    Nag, S

    1985-01-01

    Localized cancer of the prostate can be treated by radical prostatectomy, external beam irradiation, or radioactive implantation with similar survival results. Radical prostatectomy, however, almost universally results in impotency, although a new, nerve-sparing procedure may preserve potency in B1 patients. External beam irradiation radiates a large volume of tissue with significant rectal and bladder morbidity, 23-47% risk of impotency, and requires prolonged treatment (6-8 weeks). Radioactive implantation may be done suprapubically or transperineally using iodine-125, gold-198, or radon-222 permanent implantation techniques and iridium-192 or radium-226 removable implantation techniques. Interstitial iodine-125 implantation is frequently employed since it is a short procedure and limits the morbidity to a 7% incidence of impotency, 20% urinary complications, and 5% rectal complications. The overall 5-year survival of patients with iodine-125 is 79%, the survival rate decreasing with increasing T or N stage or increasing grade of tumor.

  9. Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, Daniel, E-mail: dmorton@bccancer.bc.ca; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia; Hilts, Michelle

    Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomicmore » regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite

  10. Online gamma-camera imaging of 103Pd seeds (OGIPS) for permanent breast seed implantation

    NASA Astrophysics Data System (ADS)

    Ravi, Ananth; Caldwell, Curtis B.; Keller, Brian M.; Reznik, Alla; Pignol, Jean-Philippe

    2007-09-01

    Permanent brachytherapy seed implantation is being investigated as a mode of accelerated partial breast irradiation for early stage breast cancer patients. Currently, the seeds are poorly visualized during the procedure making it difficult to perform a real-time correction of the implantation if required. The objective was to determine if a customized gamma-camera can accurately localize the seeds during implantation. Monte Carlo simulations of a CZT based gamma-camera were used to assess whether images of suitable quality could be derived by detecting the 21 keV photons emitted from 74 MBq 103Pd brachytherapy seeds. A hexagonal parallel hole collimator with a hole length of 38 mm, hole diameter of 1.2 mm and 0.2 mm septa, was modeled. The design of the gamma-camera was evaluated on a realistic model of the breast and three layers of the seed distribution (55 seeds) based on a pre-implantation CT treatment plan. The Monte Carlo simulations showed that the gamma-camera was able to localize the seeds with a maximum error of 2.0 mm, using only two views and 20 s of imaging. A gamma-camera can potentially be used as an intra-procedural image guidance system for quality assurance for permanent breast seed implantation.

  11. Improved radial dose function estimation using current version MCNP Monte-Carlo simulation: Model 6711 and ISC3500 125I brachytherapy sources.

    PubMed

    Duggan, Dennis M

    2004-12-01

    Improved cross-sections in a new version of the Monte-Carlo N-particle (MCNP) code may eliminate discrepancies between radial dose functions (as defined by American Association of Physicists in Medicine Task Group 43) derived from Monte-Carlo simulations of low-energy photon-emitting brachytherapy sources and those from measurements on the same sources with thermoluminescent dosimeters. This is demonstrated for two 125I brachytherapy seed models, the Implant Sciences Model ISC3500 (I-Plant) and the Amersham Health Model 6711, by simulating their radial dose functions with two versions of MCNP, 4c2 and 5.

  12. Synthesis of (125) I-lamivudine and (125) I-lamivudine-ursodeoxycholic acid codrug.

    PubMed

    Motaleb, M A; Abo-Kul, M; Ibrahim, Samy M; Saad, Shokry M; Arafat, Muhammad

    2016-09-01

    The preparation of (125) I-lamivudine ((125) I-3TC) and (125) I-lamivudine-ursodeoxycholic acid codrug ((125) I-3TC-UDCA), suitable for comparative biodistribution studies, is described. The synthesis of the unlabeled precursor 3TC-UDCA proceeds in an 11.6% yield, and the radiolabelling yields for (125) I-3TC and (125) I-3TC-UDCA were 89 and 92%, respectively. The final products are radiochemically pure (greater than 98%). Copyright © 2016 John Wiley & Sons, Ltd.

  13. Surface coating for prevention of metallic seed migration in tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hyunseok; Park, Jong In; Lee, Won Seok

    Purpose: In radiotherapy, metallic implants often detach from their deposited sites and migrate to other locations. This undesirable migration could cause inadequate dose coverage for permanent brachytherapy and difficulties in image-guided radiation delivery for patients. To prevent migration of implanted seeds, the authors propose a potential strategy to use a biocompatible and tissue-adhesive material called polydopamine. Methods: In this study, nonradioactive dummy seeds that have the same geometry and composition as commercial I-125 seeds were coated in polydopamine. Using scanning electron microscopy and x-ray photoelectron spectroscopy, the surface of the polydopamine-coated and noncoated seeds was characterized. The detachment stress betweenmore » the two types of seeds and the tissue was measured. The efficacy of polydopamine-coated seed was investigated through in vitro migration tests by tracing the seed location after tissue implantation and shaking for given times. The cytotoxicity of the polydopamine coating was also evaluated. Results: The results of the coating characterization have shown that polydopamine was successfully coated on the surface of the seeds. In the adhesion test, the polydopamine-coated seeds had 2.1-fold greater detachment stress than noncoated seeds. From the in vitro test, it was determined that the polydopamine-coated seed migrated shorter distances than the noncoated seed. This difference was increased with a greater length of time after implantation. Conclusions: The authors suggest that polydopamine coating is an effective technique to prevent migration of implanted seeds, especially for permanent prostate brachytherapy.« less

  14. Process for depositing I-125 onto a substrate used to manufacture I-125 sources

    DOEpatents

    McGovern, James J.; Olynyk, Joseph M.

    1988-01-01

    The invention relates to a process for depositing I-125 on a substrate which comprises contacting a predetermined surface area of substrate with Xe-125 gas, whereby the Xe-125 decays to I-125 and the I-125 in turn deposits as a solid on the surface of the substrate, the contact being for a time sufficient to deposit at least about 1 microcurie of I-125. I-125 is thereby deposited in a relatively uniform amount over the surface area of the substrate. The substrate is then assayed to determine how much I-125 has been deposited. The substrate is then divided into pieces of measured surface area, each piece therefore containing a measured amount of deposited I-125, and each piece can then be used in the manufacture of an I-125 source.

  15. An automated, fast and accurate registration method to link stranded seeds in permanent prostate implants

    NASA Astrophysics Data System (ADS)

    Westendorp, Hendrik; Nuver, Tonnis T.; Moerland, Marinus A.; Minken, André W.

    2015-10-01

    The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed movements. This linking procedure was tested on transrectal ultrasound (TRUS) and cone-beam CT (CBCT) datasets of 699 patients. These datasets were acquired intraoperatively during a dynamic implantation procedure, that combines both imaging modalities. The procedure was subdivided in four automatic linking steps. (I) The Hungarian Algorithm was applied to initially link seeds in CBCT and the corresponding TRUS datasets. (II) Strands were identified and optimized based on curvature and linefits: non optimal links were removed. (III) The positions of unlinked seeds were reviewed and were linked to incomplete strands if within curvature- and distance-thresholds. (IV) Finally, seeds close to strands were linked, also if the curvature-threshold was violated. After linking the seeds an affine transformation was applied. The procedure was repeated until the results were stable or the 6th iteration ended. All results were visually reviewed for mismatches and uncertainties. Eleven implants showed a mismatch and in 12 cases an uncertainty was identified. On average the linking procedure took 42 ms per case. This accurate and fast method has the potential to be used for other time spans, like Day 30, and other imaging modalities. It can potentially be used during a dynamic implantation procedure to faster and better evaluate the quality of the permanent prostate implant.

  16. Comparison of Dosimetric and Biologic Effective Dose Parameters for Prostate and Urethra Using {sup 131}Cs and {sup 125}I for Prostate Permanent Implant Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahgal, Arjun; Department of Radiation Oncology, Odette Cancer Centre at Sunnybrook Hospital, University of Toronto, Toronto, ON; Jabbari, Siavash

    2008-09-01

    Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for {sup 131}Cs and {sup 125}I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned {sup 125}I PPI patients were replanned manually with {sup 131}Cs, and re-planned using Inverse Planning Simulated Annealing. {sup 131}Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an {alpha}/{beta} ratio of 2 and was also calculated for the prostate using an {alpha}/{beta} ratio of 6 and a urethral {alpha}/{beta} ratio of 2.more » The primary endpoints of this study were the prostate D{sub 90} BED (pD{sub 90}BED) and urethral D{sub 30} BED normalized to the maximal potential prostate D{sub 90} BED (nuD{sub 30}BED). Results: The manual plan comparison ({alpha}/{beta} = 2) yielded no significant difference in the prostate D{sub 90} BED (median, 192 Gy{sub 2} for both isotopes). No significant difference was observed for the nuD{sub 30}BED (median, 199 Gy{sub 2} and 202 Gy{sub 2} for {sup 125}I and {sup 131}Cs, respectively). For the inverse planning simulated annealing plan comparisons ({alpha}/{beta} 2), the prostate D{sub 90} BED was significantly lower with {sup 131}Cs than with {sup 125}I (median, 177 Gy{sub 2} vs. 187 Gy{sub 2}, respectively; p = 0.01). However, the nuD{sub 30}BED was significantly greater with {sup 131}Cs than with {sup 125}I (median, 192 Gy{sub 2} vs. 189 Gy{sub 2}, respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D{sub 90} BED (p = 0.01) and significantly greater nuD{sub 30}BED for {sup 131}Cs (p = 0.01), compared with {sup 125}I, when the prostate {alpha}/{beta} ratio was 6 and the urethral {alpha}/{beta} ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the

  17. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Wen, E-mail: wenzhangxiao@126.com; Yan, Zhiping, E-mail: Yan.zhiping@zs-hospital.sh.cn; Luo, Jianjun, E-mail: luo.jianjun@zs-hospital.sh.cn

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy,more » and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for

  18. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    PubMed

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  19. Single-nucleotide polymorphisms studied for associations with urinary toxicity from (125)I prostate brachytherapy implants.

    PubMed

    Usmani, Nawaid; Leong, Nelson; Martell, Kevin; Lan, Lanna; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Murtha, Albert; Amanie, John; Sloboda, Ron; Murray, David; Parliament, Matthew

    2014-01-01

    To identify clinical, dosimetric, and genetic factors that are associated with late urinary toxicity after a (125)I prostate brachytherapy implant. Genomic DNA from 296 men treated with (125)I prostate brachytherapy monotherapy was extracted from saliva samples for this study. A retrospective database was compiled including clinical, dosimetric, and toxicity data for this cohort of patients. Fourteen candidate single-nucleotide polymorphism (SNPs) from 13 genes (TP53, ERCC2, GSTP1, NOS, TGFβ1, MSH6, RAD51, ATM, LIG4, XRCC1, XRCC3, GSTA1, and SOD2) were tested in this cohort for correlations with toxicity. This study identified 217 men with at least 2 years of followup. Of these, 39 patients developed Grade ≥2 late urinary complications with a transurethral resection of prostate, urethral stricture, gross hematuria, or a sustained increase in their International Prostate Symptom Score. The only clinical or dosimetric factor that was associated with late urinary toxicity was age (p = 0.02). None of the 14 SNPs tested in this study were associated with late urinary toxicity in the univariate analysis. This study identified age as the only variable being associated with late urinary toxicity. However, the small sample size and the candidate gene approach used in this study mean that further investigations are essential. Genome-wide association studies are emerging as the preferred approach for future radiogenomic studies to overcome the limitations from a candidate gene approach. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  20. Sowing seeds: transperineal implantation.

    PubMed

    Amerine, E; Nagle, G M; Bollinger, J R

    2000-02-01

    Prostate cancer, the second leading cause of male deaths in the United States, has increased by 126% since 1987 (Stephenson, 1998). Early diagnosis is attributed to public awareness and technologic advances. Multiple options for definitive treatment with equally positive outcomes dramatically influence the patient's decision-making process. One popular option for these patients is transperineal implantation of radioactive seeds into the prostate.

  1. Treasure of the Past IX: Exposure Standardization of Iodine-125 Seeds Used for Brachytherapy

    PubMed Central

    Loftus, T. P.

    2001-01-01

    A method for calibrating iodine-125 seeds in terms of exposure has been established. The standard free-air ionization chamber, used for measuring soft x rays, was chosen for the measurements. Arrays of four to six seeds were used to enhance the ionization-current-to-background-current ratio. Seeds from an array were measured individually in a re-entrant chamber. The quotient of the exposure rate for the array by the sum of the ionization currents in the re-entrant chamber is the calibration factor for the re-entrant chamber. Calibration factors were established for three types of iodine-125 seeds. The overall uncertainty for the seed exposure calibrations is less than 6%. PMID:27500052

  2. Efficacy and safety of iodine-125 radioactive seeds brachytherapy for advanced non-small cell lung cancer-A meta-analysis.

    PubMed

    Zhang, Wenchao; Li, Jiawei; Li, Ran; Zhang, Ying; Han, Mingyong; Ma, Wei

    This meta-analysis was conducted to investigate the efficacy and safety of 125 I brachytherapy for locally advanced non-small cell lung cancer (NSCLC). Trials comparing 125 I brachytherapy with chemotherapy in NSCLC were identified. Meta-analysis was performed to obtain pooled risk ratios for an overall response rate (ORR), disease control rate (DCR) and complications, and pooled hazard ratio for overall survival (OS). Fifteen studies including 1188 cases were included. The pooled result indicated that there were significant differences in ORR, DCR, and OS between 125 I brachytherapy combined with chemotherapy and chemotherapy alone, but no statistic differences in gastrointestinal symptoms, leukopenia, myelosuppression, and hemoglobin reduction. Patients treated with 125 I brachytherapy combined with chemotherapy have a higher relative risk of pneumothorax, bloody sputum, and pneumorrhagia compared with chemotherapy alone. Seeds migration only occurred in the group treated with 125 I brachytherapy. There were significant differences in ORR, DCR, and myelosuppression between 125 I brachytherapy alone and chemotherapy. 125 I brachytherapy combined with chemotherapy can significantly enhance the clinical efficacy and improve the OS of patients with advanced NSCLC without increasing the incidence of complications of chemotherapy. 125 I brachytherapy alone can significantly enhance the clinical efficacy and reduce the incidence of myelosuppression compared with chemotherapy. However, 125 I brachytherapy may cause lung injury. Large sample and higher-quality randomized controlled trials are needed to confirm the pooled results of complications. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giaddui, T; Hardin, M; To, D

    Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seedsmore » and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.« less

  4. Prostate implant nomograms for the North American scientific {sup 103}Pd seed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Jay J.; Stevens, Ritchie N

    Palladium-103-({sup 103}Pd) seed has been increasingly used in prostate implantation as either definitive or boost therapy because of its shorter half-life and higher initial dose rate. Because a growing number of radiation oncologists prefer real-time implantation in the operating room, it will be helpful if the total activity of the seeds can be determined based on the gland size before the patient is taken to the operating room. Based on our clinic data, nomograms have therefore been developed for one of the widely used {sup 103}Pd seeds, the MED3633 seed, which is produced by North American Scientific, Inc. (NASI). Themore » total activities for implant volume ranging from 15 cc to 55 cc are provided for both seed 'monotherapy' and seed boost.« less

  5. Urinary morbidity following ultrasound-guided transperineal prostate seed implantation.

    PubMed

    Gelblum, D Y; Potters, L; Ashley, R; Waldbaum, R; Wang, X H; Leibel, S

    1999-08-01

    To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125I in 165 patients and with 103Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125I (pre TG43) or 120 Gy with 103Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA > or = 10 and/or Gleason score > or = 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125I or 103Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of postimplant urinary toxicity. The

  6. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J. L., E-mail: jlreed2@wisc.edu; Micka, J. A.; Culberson, W. S.

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a {sup 60}Co teletherapy source. The brachytherapy sources measured were the Best 2301 {sup 125}I seed, the OncoSeed 6711 {sup 125}I seed, and the Best 2335 {sup 103}Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the {sup 60}Co irradiations. Monte Carlo (MC) simulations were usedmore » to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the {sup 60}Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for {sup 125}I and {sup 103}Pd relative to {sup 60}Co. Results: The relative TLD intrinsic energy dependences (relative to {sup 60}Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for {sup 125}I and {sup 103}Pd sources relative to {sup 60}Co. TLD measurements of absolute dose around {sup 125}I and {sup 103}Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.« less

  7. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    NASA Astrophysics Data System (ADS)

    Xu, Gang; Wang, Xiao-teng; Gan, Cai-ling; Fang, Yan-qiong; Zhang, Meng

    2012-09-01

    To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N+ with energy of 25 keV was applied to treat the dry seed at six different doses. N+ beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 × 1016 to 15 × 1016 ions cm-2 severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 × 1016 ion cm-2, biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 × 1016 ions cm-2 may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA-GSH cycle appeared to be for regeneration of HAsA.

  8. Reevaluation of the AAPM TG-43 brachytherapy dosimetry parameters for an 125I seed, and the influence of eye plaque design on dose distributions and dose-volume histograms

    NASA Astrophysics Data System (ADS)

    Aryal, Prakash

    The TG-43 dosimetry parameters of the Advantage(TM) 125I model IAI-125A brachytherapy seed were studied. An investigation using modern MCNP radiation transport code with updated cross-section libraries was performed. Twelve different simulation conditions were studied for a single seed by varying the coating thickness, mass density, photon energy spectrum and cross-section library. The dose rate was found to be 6.3% lower at 1 cm in comparison to published results. New TG-43 dosimetry parameters are proposed. The dose distribution for a brachytherapy eye plaque, model EP917, was investigated, including the effects of collimation from high-Z slots. Dose distributions for 26 slot designs were determined using Monte Carlo methods and compared between the published literature, a clinical treatment planning system, and physical measurements. The dosimetric effect of the composition and mass density of the gold backing was shown to be less than 3%. Slot depth, width, and length changed the central axis (CAX) dose distributions by < 1% per 0.1 mm in design variation. Seed shifts in the slot towards the eye and shifts of the 125I-laden silver rod within the seed had the greatest impact on the CAX dose distribution, changing it by 14%, 9%, 4.3%, and 2.7% at 1, 2, 5, and 10 mm, respectively, from the inner scleral surface. The measured, full plaque slot geometry delivered 2.4% +/- 1.1% higher dose along the plaque's CAX than the geometry provided by the manufacturer and 2.2%+/-2.3% higher than Plaque Simulator(TM) (PS) treatment planning software (version 5.7.6). The D10 for the simulated tumor, inner sclera, and outer sclera for the measured slot plaque to manufacturer provided slot design was 9%, 10%, and 19% higher, respectively. In comparison to the measured plaque design, a theoretical plaque having narrow and deep slots delivered 30%, 37%, and 62% lower D 10 doses to the tumor, inner sclera, and outer sclera, respectively. CAX doses at --1, 0, 1, and 2 mm were also

  9. Defining the rectal dose constraint for permanent radioactive seed implantation of the prostate.

    PubMed

    Albert, Michele; Song, Jun S; Schultz, Delray; Cormack, Robert A; Tempany, Clare M; Haker, Steve; Devlin, Phillip M; Beard, Clair; Hurwitz, Mark D; Suh, Wonsuk W; Jolesz, Ferenc; D'Amico, Anthony V

    2008-01-01

    This study was performed to define the rectal dose constraint that would predict late rectal bleeding requiring argon plasma coagulation (APC) following prostate brachy mono-therapy. Between February 1999 and April 2002, 91 patients with low risk prostate cancer underwent permanent I(125) radioactive seed implantation without the use of supplemental external beam radiation or androgen suppression therapy. Patients received both CT and MRI scans 6 weeks postimplant for evaluation of dosimetry. The CT and MRI scans were fused. Rectal volumes were contoured on the T2 weighted MR images. For those patients requiring APC, the date on which a patient reported rectal bleeding was recorded. A Cox regression analysis was performed to assess whether there was a significant association between the rectal volume (continuous) exceeding 100 Gy time rectal bleeding. Comparisons of estimates of rectal bleeding requiring APC were made using a 2-sided log rank test. There was a significant association (hazard ratio = 5.6 [95% confidence interval: 1.3, 23.8]; P = 0.002) between the rectal volume exceeding 100 Gy and rectal bleeding requiring APC. After a median follow-up of 4.25 (1-6) years, no patient with less than a median value of 8 cc of rectum exceeding 100 Gy required APC, whereas 20% (P = 0.004) were estimated to require APC within 3 years following treatment. Keeping the rectal volume receiving more than 100 Gy below 8 cc will minimize the risk of rectal bleeding requiring APC following I(125) permanent prostate brachy mono-therapy.

  10. Monte Carlo calculated doses to treatment volumes and organs at risk for permanent implant lung brachytherapy

    NASA Astrophysics Data System (ADS)

    Sutherland, J. G. H.; Furutani, K. M.; Thomson, R. M.

    2013-10-01

    Iodine-125 (125I) and Caesium-131 (131Cs) brachytherapy have been used with sublobar resection to treat stage I non-small cell lung cancer and other radionuclides, 169Yb and 103Pd, are considered for these treatments. This work investigates the dosimetry of permanent implant lung brachytherapy for a range of source energies and various implant sites in the lung. Monte Carlo calculated doses are calculated in a patient CT-derived computational phantom using the EGsnrc user-code BrachyDose. Calculations are performed for 103Pd, 125I, 131Cs seeds and 50 and 100 keV point sources for 17 implant positions. Doses to treatment volumes, ipsilateral lung, aorta, and heart are determined and compared to those determined using the TG-43 approach. Considerable variation with source energy and differences between model-based and TG-43 doses are found for both treatment volumes and organs. Doses to the heart and aorta generally increase with increasing source energy. TG-43 underestimates the dose to the heart and aorta for all implants except those nearest to these organs where the dose is overestimated. Results suggest that model-based dose calculations are crucial for selecting prescription doses, comparing clinical endpoints, and studying radiobiological effects for permanent implant lung brachytherapy.

  11. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET.

    PubMed

    Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D

    2013-03-01

    In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k = 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). ISA causes the delivered dose

  12. Prostate seed implant quality assessment using MR and CT image fusion.

    PubMed

    Amdur, R J; Gladstone, D; Leopold, K A; Harris, R D

    1999-01-01

    After a seed implant of the prostate, computerized tomography (CT) is ideal for determining seed distribution but soft tissue anatomy is frequently not well visualized. Magnetic resonance (MR) images soft tissue anatomy well but seed visualization is problematic. We describe a method of fusing CT and MR images to exploit the advantages of both of these modalities when assessing the quality of a prostate seed implant. Eleven consecutive prostate seed implant patients were imaged with axial MR and CT scans. MR and CT images were fused in three dimensions using the Pinnacle 3.0 version of the ADAC treatment planning system. The urethra and bladder base were used to "line up" MR and CT image sets during image fusion. Alignment was accomplished using translation and rotation in the three ortho-normal planes. Accuracy of image fusion was evaluated by calculating the maximum deviation in millimeters between the center of the urethra on axial MR versus CT images. Implant quality was determined by comparing dosimetric results to previously set parameters. Image fusion was performed with a high degree of accuracy. When lining up the urethra and base of bladder, the maximum difference in axial position of the urethra between MR and CT averaged 2.5 mm (range 1.3-4.0 mm, SD 0.9 mm). By projecting CT-derived dose distributions over MR images of soft tissue structures, qualitative and quantitative evaluation of implant quality is straightforward. The image-fusion process we describe provides a sophisticated way of assessing the quality of a prostate seed implant. Commercial software makes the process time-efficient and available to any clinical practice with a high-quality treatment planning system. While we use MR to image soft tissue structures, the process could be used with any imaging modality that is able to visualize the prostatic urethra (e.g., ultrasound).

  13. A virtual fluoroscopy system to verify seed positioning accuracy during prostate permanent seed implants.

    PubMed

    Sarkar, V; Gutierrez, A N; Stathakis, S; Swanson, G P; Papanikolaou, N

    2009-01-01

    The purpose of this project was to develop a software platform to produce a virtual fluoroscopic image as an aid for permanent prostate seed implants. Seed location information from a pre-plan was extracted and used as input to in-house developed software to produce a virtual fluoroscopic image. In order to account for differences in patient positioning on the day of treatment, the user was given the ability to make changes to the virtual image. The system has been shown to work as expected for all test cases. The system allows for quick (on average less than 10 sec) generation of a virtual fluoroscopic image of the planned seed pattern. The image can be used as a verification tool to aid the physician in evaluating how close the implant is to the planned distribution throughout the procedure and enable remedial action should a large deviation be observed.

  14. WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steiner, J; Matthews, K; Jia, G

    Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strandsmore » of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding

  15. Ejaculatory function after permanent 125I prostate brachytherapy for localized prostate cancer.

    PubMed

    Huyghe, Eric; Delannes, Martine; Wagner, Fabien; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc

    2009-05-01

    Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent (125)I prostate brachytherapy for localized prostate cancer. Of 270 sexually active men with localized prostate cancer treated with permanent (125)I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.

  16. BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry

    NASA Astrophysics Data System (ADS)

    Alnaghy, S.; Loo, K. J.; Cutajar, D. L.; Jalayer, M.; Tenconi, C.; Favoino, M.; Rietti, R.; Tartaglia, M.; Carriero, F.; Safavi-Naeini, M.; Bucci, J.; Jakubek, J.; Pospisil, S.; Zaider, M.; Lerch, M. L. F.; Rosenfeld, A. B.; Petasecca, M.

    2016-05-01

    BrachyView is a novel in-body imaging system utilising high-resolution pixelated silicon detectors (Timepix) and a pinhole collimator for brachytherapy source localisation. Recent studies have investigated various options for real-time intraoperative dynamic dose treatment planning to increase the quality of implants. In a previous proof-of-concept study, the justification of the pinhole concept was shown, allowing for the next step whereby multiple active seeds are implanted into a PMMA phantom to simulate a more realistic clinical scenario. In this study, 20 seeds were implanted and imaged using a lead pinhole of 400 μ m diameter. BrachyView was able to resolve the seed positions within 1-2 mm of expected positions, which was verified by co-registering with a full clinical post-implant CT scan.

  17. Biodegradable seeds of holmium don't change neurological function after implant in brain of rats.

    PubMed

    Diniz, Mirla Fiuza; Ferreira, Diogo Milioli; de Lima, Wanderson Geraldo; Pedrosa, Maria Lucia; Silva, Marcelo Eustáquio; de Almeida Araujo, Stanley; Sampaio, Kinulpe Honorato; de Campos, Tarcisio Passos Ribeiro; Siqueira, Savio Lana

    2017-01-01

    To evaluate the surgical procedure and parenchymal abnormalities related to implantation of ceramic seeds with holmium-165 in rats' brain. An effective method of cancer treatment is brachytherapy in which radioactive seeds are implanted in the tumor, generating a high local dose of ionizing radiation that can eliminate tumor cells while protecting the surrounding healthy tissue. Biodegradable Ho 166 -ceramic-seeds have been addressed recently. The experiments in this study were approved by the Ethics Committee on Animal Use at the Federal University of Ouro Preto, protocol number 2012/034. Twenty-one adult Fischer rats were divided into Naive Group, Sham Group and Group for seed implants (ISH). Surgical procedures for implantation of biodegradable seeds were done and 30 days after the implant radiographic examination and biopsy of the brain were performed. Neurological assays were also accomplished to exclude any injury resulting from either surgery or implantation of the seeds. Radiographic examination confirmed the location of the seeds in the brain. Neurological assays showed animals with regular spontaneous activity. The histological analysis showed an increase of inflammatory cells in the brain of the ISH group. Electron microscopy evidenced cytoplasmic organelles to be unchanged. Biochemical analyzes indicate there was neither oxidative stress nor oxidative damage in the ISH brain. CAT activity showed no difference between the groups as well as lipid peroxidation measured by TBARS. The analysis of the data pointed out that the performed procedure is safe as no animal showed alterations of the neurological parameters and the seeds did not promote histological architectural changes in the brain tissue.

  18. Experimental and Monte Carlo measurements of dose perturbation around a non-radioactive brachytherapy seed in external beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Steinman, James P.

    I-125 seeds used in permanent prostate brachytherapy are composed of high-Z metals and may number from 40 to over 100 in a typical implant. If any supplemental external beam treatment is administered afterward (as for salvaging failed brachytherapy treatment), it is possible that the seeds may cause substantial dose perturbation which will depend on numerous factors (photon energy, depth, field size, number of seeds, etc.) and this effect needs to be thoroughly investigated. Film measurements were primarily done using Kodak XV2 layered above and below a non-radioactive I-125 seed placed in a groove on a Lucite plate with 5 cm buildup and 10 cm backscatter added at 95 cm SSD. The phantom was irradiated with and without seed with 6 MV photons for a 1 x 1 cm2 field size. Monte Carlo simulations were carried out using DOSXYZnrc using the same parameters and compared with Gafchromic EBT2 film. Other comparisons looked at changing energy, depth, and field size in both with and without seeds configuration. This study was further extended to include metals of various Z of the seed's dimensions and also looked into effect of 3 seeds spaced 0.5 cm vertically. Another measurement was done using two opposing fields using single as well as 3 seed configuration to see whether the dose enhancement and attenuation cancel out in multi-field treatments which is the norm clinically in a prostate treatment. For a single I-125 seed, on XV film a localized dose enhancement of 6.3% upstream and -10.9% downstream was noticed. With three seeds, this effect did not change. With two opposing fields, a cold spot around the seed of ~3% was noticed from film measurements. Increasing energy and field size decreased the effect while increase in Z of material greatly increased the effect. Increasing depth appeared to have no effect. DOSXYZnrc and EBT2 film verified maximum dose enhancement of +15% upstream and -20% downstream of the I-125 seed surface. In general, the range of the effect was

  19. Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds.

    PubMed

    Morrison, Hali; Menon, Geetha; Larocque, Matthew P; van Veelen, Bob; Niatsetski, Yury; Weis, Ezekiel; Sloboda, Ron S

    2018-05-04

    To investigate the dose calculation accuracy of the Advanced Collapsed cone Engine (ACE) algorithm for ocular brachytherapy using a COMS plaque loaded with I-125 seeds for two heterogeneous patient tissue scenarios. The Oncura model 6711 I-125 seed and 16 mm COMS plaque were added to a research version (v4.6) of the Oncentra ® Brachy (OcB) treatment planning system (TPS) for dose calculations using ACE. Treatment plans were created for two heterogeneous cases: (a) a voxelized eye phantom comprising realistic eye materials and densities and (b) a patient CT dataset with variable densities throughout the dataset. ACE dose calculations were performed using a high accuracy mode, high-resolution calculation grid matching the imported CT datasets (0.5 × 0.5 × 0.5 mm 3 ), and a user-defined CT calibration curve. The accuracy of ACE was evaluated by replicating the plan geometries and comparing to Monte Carlo (MC) calculated doses obtained using MCNP6. The effects of the heterogeneous patient tissues on the dose distributions were also evaluated by performing the ACE and MCNP6 calculations for the same scenarios but setting all tissues and air to water. Average local percent dose differences between ACE and MC within contoured structures and at points of interest for both scenarios ranged from 1.2% to 20.9%, and along the plaque central axis (CAX) from 0.7% to 7.8%. The largest differences occurred in the plaque penumbra (up to 17%), and at contoured structure interfaces (up to 20%). Other regions in the eye agreed more closely, within the uncertainties of ACE dose calculations (~5%). Compared to that, dose differences between water-based and fully heterogeneous tissue simulations were up to 27%. Overall, ACE dosimetry agreed well with MC in the tumor volume and along the plaque CAX for the two heterogeneous tissue scenarios, indicating that ACE could potentially be used for clinical ocular brachytherapy dosimetry. In general, ACE data matched the fully heterogeneous MC

  20. A Monte Carlo investigation of lung brachytherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Sutherland, J. G. H.; Furutani, K. M.; Thomson, R. M.

    2013-07-01

    Iodine-125 (125I) and Caesium-131 (131Cs) brachytherapy have been used in conjunction with sublobar resection to reduce the local recurrence of stage I non-small cell lung cancer compared with resection alone. Treatment planning for this procedure is typically performed using only a seed activity nomogram or look-up table to determine seed strand spacing for the implanted mesh. Since the post-implant seed geometry is difficult to predict, the nomogram is calculated using the TG-43 formalism for seeds in a planar geometry. In this work, the EGSnrc user-code BrachyDose is used to recalculate nomograms using a variety of tissue models for 125I and 131Cs seeds. Calculated prescription doses are compared to those calculated using TG-43. Additionally, patient CT and contour data are used to generate virtual implants to study the effects that post-implant deformation and patient-specific tissue heterogeneity have on perturbing nomogram-derived dose distributions. Differences of up to 25% in calculated prescription dose are found between TG-43 and Monte Carlo calculations with the TG-43 formalism underestimating prescription doses in general. Differences between the TG-43 formalism and Monte Carlo calculated prescription doses are greater for 125I than for 131Cs seeds. Dose distributions are found to change significantly based on implant deformation and tissues surrounding implants for patient-specific virtual implants. Results suggest that accounting for seed grid deformation and the effects of non-water media, at least approximately, are likely required to reliably predict dose distributions in lung brachytherapy patients.

  1. Radio-guided occult lesion localisation using iodine 125 Seeds “ROLLIS” to guide surgical removal of an impalpable posterior chest wall melanoma metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dissanayake, Shashini; Dissanayake, Deepthi; Taylor, Donna B

    Cancer screening and surveillance programmes and the use of sophisticated imaging tools such as positron emission tomography-computed tomography (PET-CT) have increased the detection of impalpable lesions requiring imaging guidance for excision. A new technique involves intra-lesional insertion of a low-activity iodine-125 ({sup 125}I) seed and detection of the radioactive signal in theatre using a hand-held gamma probe to guide surgery. Whilst several studies describe using this method to guide the removal of impalpable breast lesions, only a handful of publications report its use to guide excision of lesions outside the breast. We describe a case in which radio-guided occult lesionmore » localisation using an iodine 125 seed was used to guide excision of an impalpable posterior chest wall metastasis detected on PET-CT.« less

  2. Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy.

    PubMed

    Hueso-González, Fernando; Ballester, Facundo; Perez-Calatayud, Jose; Siebert, Frank-André; Vijande, Javier

    RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose-rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125 I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Dose-volume histogram-related parameters like prostate D 90 , rectum D 2cc , or urethra D 10 obtained with RayStretch agree within a few percent with the detailed MC results for all cases considered. The robustness and compatibility of RayStretch with commercial treatment planning systems indicate its applicability in clinical practice for dosimetric corrections in prostate calcifications. Its use during intraoperative ultrasound planning is foreseen. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Chemoembolization and stenting combined with iodine-125 seed strands for the treatment of hepatocellular carcinoma with inferior vena cava obstruction

    PubMed Central

    LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING

    2015-01-01

    The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424

  4. Ejaculatory Function After Permanent {sup 125}I Prostate Brachytherapy for Localized Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huyghe, Eric; Department of Urology and Andrology, Paul Sabatier University, CHU Paule de Viguier, Toulouse; Delannes, Martine

    Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent {sup 125}I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent {sup 125}I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of themore » 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.« less

  5. Nanodosimetry of (125)I Auger electrons.

    PubMed

    Bantsar, Aliaksandr; Pszona, Stanislaw

    2012-12-01

    The nanodosimetric description of the radiation action of Auger electrons on nitrogen targets of nanometric size is presented. Experimental microdosimetry at nanometer scale for Auger electrons has been accomplished with the set-up called Jet Counter. This consists of a pulse-operated valve which injects an expanding nitrogen jet into an interaction chamber where a gaseous sensitive volume of cylindrical shape is created. The ionization cluster size distributions (ICSD) created by Auger electrons emitted by (125)I while crossing a nanometer-sized volume have been measured. The ICSD for the sensitive volumes corresponding to 3 and 12 nm in diameter (in unit density 1 g/cm(3)) irradiated by electrons emitted by a (125)I source were collected and compared with the corresponding Monte Carlo (MC) simulation. The preliminary results of the experiments with Auger electrons of (125)I interacting with a nitrogen jet having nanometric size comparable to a deoxyribonucleic acid (DNA) and nucleosome, showing the discrete spectrum of ICSD with extended cluster size, are described. The presented paper describes for the first time the nanodosimetric experiments with Auger electrons emitted by (125)I. A set of the new descriptors of the radiation quality describing the radiation effect at nanometer level is proposed. The ICSD were determined for the first time for an Auger emitter of (125)I.

  6. SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warrell, G; Shvydka, D; Chen, C

    Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains onemore » of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has

  7. Spectral CT with monochromatic imaging and metal artifacts reduction software for artifacts reduction of ¹²⁵I radioactive seeds in liver brachytherapy.

    PubMed

    Yang, Qiuxia; Peng, Sheng; Wu, Jing; Ban, Xiaohua; He, Mingyan; Xie, Chuanmiao; Zhang, Rong

    2015-11-01

    To investigate the optimal monochromatic energy for artifacts reduction from (125)I seeds as well as image improvement in the vicinity of seeds on monochromatic images with and without metal artifacts reduction software (MARS) and to compare this with traditional 120-kVp images, so as to evaluate the application value of gemstone spectral imaging for reducing artifacts from (125)I seeds in liver brachytherapy. A total of 45 tumors from 25 patients treated with (125)I seed brachytherapy in the liver were enrolled in this study. Multiphasic spectral computed tomography (CT) scanning was performed for each patient. After a delay time of 15 s of portal vein phase, a traditional 120-kVp scan was performed, focusing on several planes of (125)I seeds only. The artifact index (AI) in the vicinity of seeds and the standard deviation (SD) of the CT density of region of interest in the outside liver parenchyma were calculated. Artifact appearance was evaluated and classified on reconstructed monochromatic S and 120-kVp images. Image quality in the vicinity of seeds of three data sets were evaluated using a 1-5 scale scoring method. The Friedman rank-sum test was used to estimate the scoring results of image quality. The greatest noise in monochromatic images was found at 40 keV (SD = 27.38, AI = 206.40). The optimal monochromatic energy was found at 75 keV, which provided almost the least image noise (SD = 10.01) and good performance in artifact reduction (AI = 102.73). Image noise and AI reduction at 75 keV was decreased by 63.44 and 50.23%, compared with at 40 keV. Near-field thick artifacts were obvious in all 45 lesions, in 120-kVp images, and 75-keV images, but basically reduced in 75 keV MARS images and artifacts completely invisible in 7 lesions. The number of diagnosable images (score ≥3) was significantly more in the 75-keV MARS group (28/45), and the 75-keV group (22/45) than in the 120-kVp group (11/45) (p < 0.0167 for both). Compared with 120-kVp images alone

  8. Sci-Thur PM – Brachytherapy 03: Identifying the impact of seroma visualization on permanent breast seed implant brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, Daniel; Batchelar, Deidre; Hilts, Michelle

    Purpose: Uncertainties in target identification can reduce treatment accuracy in permanent breast seed implant (PBSI) brachytherapy. This study evaluates the relationship between seroma visualization and seed placement accuracy. Methods: Spatially co-registered CT and 3D ultrasound (US) images were acquired for 10 patients receiving PBSI. Seromas were retrospectively contoured independently by 3 radiation oncologists on both CT and US and respective consensus volumes were defined, CTV{sub CT} and CTV{sub US}. The seroma clarity and inter-user conformity index (CI), as well as inter-modality CI, volume, and positional differences were evaluated. Correlations with seed placement accuracy were then assessed. CTVs were expanded bymore » 1.25cm to create PTV{sub CT} and PTV{sub US} and evaluate the conformity with PTV{sub Clinical} (CTV{sub Clinical}+1.25cm) used in treatment planning. The change in PTV coincidence by expanding PTV{sub Clinical} by 0.25cm was determined. Results: CTV{sub US} were a mean 68 ± 12% smaller than CTV{sub CT} and generally had improved clarity and inter-user conformity. No correlations between seed displacement and CTV{sub US}-CTV{sub CT} positional difference or CI were observed. Greater seed displacements were associated with larger CTV{sub US}-CTV{sub CT} volume differences (r=−0.65) and inter-user CT CI (r=−0.74). A median (range) 88% (71–99%) of PTV{sub CT} and 83% (69–100%) of PTV{sub US} were contained within PTV{sub Clinical}. Expanding treatment margins to 1.5cm increased coincidence to 98% (86–100%) and 94% (82–100%), respectively. Conclusions: Differences in seroma visualization impacts seed displacement in PBSI. Reducing dependence on CT by incorporating 3DUS into target identification, or expanding CT-based treatment margins to 1.5cm may reduce or mitigate uncertainties related to seroma visualization.« less

  9. SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, X; Duan, J; Popple, R

    2014-06-01

    Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changedmore » through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.« less

  10. Photon counting readout pixel array in 0.18-μm CMOS technology for on-line gamma-ray imaging of 103palladium seeds for permanent breast seed implant (PBSI) brachytherapy

    NASA Astrophysics Data System (ADS)

    Goldan, A. H.; Karim, K. S.; Reznik, A.; Caldwell, C. B.; Rowlands, J. A.

    2008-03-01

    Permanent breast seed implant (PBSI) brachytherapy technique was recently introduced as an alternative to high dose rate (HDR) brachytherapy and involves the permanent implantation of radioactive 103Palladium seeds into the surgical cavity of the breast for cancer treatment. To enable accurate seed implantation, this research introduces a gamma camera based on a hybrid amorphous selenium detector and CMOS readout pixel architecture for real-time imaging of 103Palladium seeds during the PBSI procedure. A prototype chip was designed and fabricated in 0.18-μm n-well CMOS process. We present the experimental results obtained from this integrated photon counting readout pixel.

  11. 125I eye plaque dose distribution including penumbra characteristics.

    PubMed

    de la Zerda, A; Chiu-Tsao, S T; Lin, J; Boulay, L L; Kanna, I; Kim, J H; Tsao, H S

    1996-03-01

    The two main purposes of this work are (1) to determine the penumbra characteristics for 125I eye plaque and the relative influence of the plaque and eye-air interface on the dose distribution, and (2) to initiate development of a treatment planning algorithm for clinical dose calculations. Dose was measured in a newly designed solid water eye phantom for an 125I (6711) seed at the center of a 20 mm COMS eye plaque using thermoluminescent dosimeter (TLD) "cubes" and "minichips" inside and outside the eye, in the longitudinal and transverse central planes. TLD cubes were used in most locations, except for short distances from the seed and in the penumbra region. In the presence of both the plaque and the eye-air interface, the dose along the central axis was found to be reduced by 10% at 1 cm and up to 20% at 2.5 cm, relative to the bulk homogeneous phantom case. In addition, the overall dose reduction was greater for larger off-axis coordinates at a given depth. The penumbra characteristics due to the lip collimation were quantified, particularly the dependence of penumbra center and width on depth. Only small differences were observed between the profiles in the transverse and longitudinal planes. In the bulk geometry (without the eye-air interface), the dose reduction due to the presence of the plaque alone was found to be 7% at a depth of 2.5 cm. The additional reduction of 13% observed, with the presence of eye-air interface (20% combined), can be attributed to the lack of backscattering from the air in front of the eye. The dose-reduction effect due to the anterior air interface alone became unnoticeable at a depth of 1.1 cm (1.5 cm from the eye-air interface). An analytic fit to measured data was developed for clinical dose calculations for a centrally loaded seed. The central axis values of the dose rates multiplied by distance squared, Dr2, were fitted with a double exponential function of depth. The off-axis profile of Dr2, at a given depth, was

  12. 40 CFR 1027.125 - Can I get a refund?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Can I get a refund? 1027.125 Section 1027.125 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS FEES FOR ENGINE, VEHICLE, AND EQUIPMENT COMPLIANCE PROGRAMS § 1027.125 Can I get a refund? (a) We will...

  13. SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Safigholi, H; Soliman, A; Song, W

    Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summedmore » using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.« less

  14. 25 CFR 171.125 - Can I appeal BIA decisions?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Can I appeal BIA decisions? 171.125 Section 171.125 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION OPERATION AND MAINTENANCE General Provisions § 171.125 Can I appeal BIA decisions? (a) You may appeal our decisions in...

  15. 125Mbps ultra-wideband system evaluation for cortical implant devices.

    PubMed

    Luo, Yi; Winstead, Chris; Chiang, Patrick

    2012-01-01

    This paper evaluates the performance of a 125Mbps Impulse Ratio Ultra-Wideband (IR-UWB) system for cortical implant devices by using low-Q inductive coil link operating in the near-field domain. We examine design tradeoffs between transmitted signal amplitude, reliability, noise and clock jitter. The IR-UWB system is modeled using measured parameters from a reported UWB transceiver implemented in 90nm-CMOS technology. Non-optimized inductive coupling coils with low-Q value for near-field data transmission are modeled in order to build a full channel from the transmitter (Tx) to the receiver (Rx). On-off keying (OOK) modulation is used together with a low-complexity convolutional error correcting code. The simulation results show that even though the low-Q coils decrease the amplitude of the received pulses, the UWB system can still achieve acceptable performance when error correction is used. These results predict that UWB is a good candidate for delivering high data rates in cortical implant devices.

  16. Comparison of intraoperative dosimetric implant representation with postimplant dosimetry in patients receiving prostate brachytherapy.

    PubMed

    Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G

    2003-01-01

    To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (p<0.001), and the 1-month CT volume was 43.6 cm(3) (p<0.001). The mean difference between the OR dose received by 90% of the prostate (D(90)) and the CT D(90) was 3.4% (95% confidence interval, 2.5-6.6%; p=0.034). The mean dose to 30% of the urethra was 120% of prescription in the OR and 138% on CT. The mean difference was 18% (95% confidence interval, 13-24%; p<0.001). Although small differences exist between the OR and CT dosimetry results, these data suggest that this intraoperative implant dosimetric representation system provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.

  17. Monte Carlo dosimetry for {sup 103}Pd, {sup 125}I, and {sup 131}Cs ocular brachytherapy with various plaque models using an eye phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesperance, Marielle; Martinov, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca

    Purpose: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing{sup 103}Pd, {sup 125}I, or {sup 131}Cs seeds with model-based dose calculations. Methods: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed usingmore » the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models. Results: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for{sup 125}I and {sup 131}Cs, and up to 17% for {sup 103}Pd, and in the lens region by up to 29% for {sup 125}I, 34% for {sup 103}Pd, and 28% for {sup 131}Cs. For the same prescription dose to the tumor apex, the lowest doses to

  18. Effect of metal ions on the enzymatic hydrolysis of hemp seed oil by lipase Candida sp. 99-125.

    PubMed

    Lu, Jike; Wang, Pei; Ke, Zhaodi; Liu, Xin; Kang, Qiaozhen; Hao, Limin

    2018-07-15

    In order to study the effect of metal ions on the enzymatic hydrolysis of hemp seed oil by Candida sp. 99-125, the spectroscopy, stability and hydrolytic activity of the biocatalyst were investigated in presence of Ca 2+ , Mg 2+ , Fe 2+ , Fe 3+ , Cu 2+ , Sn 2+ , Pb 2+ , Zn 2+ and Ba 2+ metal ions, respectively. The UV spectroscopy showed that all the metal ions enhanced the absorbance but the decrease of fluorescence intensity was observed. All the metal ions could improve the lipase thermal stability except Cu 2+ and Ba 2+ . Hydrolysis of hemp seed oil proved that Ca 2+ , Fe 3+ , Pb 2+ and Ba 2+ could significantly improve the hydrolytic rate, and metal ions could influence lipase selectivity. The study revealed that metal ions could improve lipase stability, hydrolysis activity in the hydrolytic process of hemp seed oil by Candida sp. 99-125. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. High activity iodine 125 endocurietherapy for recurrent skull base tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, P.P.; Good, R.R.; Leibrock, L.G.

    1988-04-15

    Experience with endocurietherapy of skull base tumors is reviewed. We present our cases of recurrent pituitary hemangiopericytoma, radiation-induced recurrent meningioma, recurrent clival chordoma, recurrent nasopharyngeal cancer involving the cavernous sinus, and recurrent parotid carcinoma of the skull base which were all successfully retreated with high-activity 125-iodine (I-125) permanent implantation.76 references.

  20. Evaluation of CA125 and NT-proBNP values in patients undergoing transcatheter aortic valve implantation

    PubMed Central

    Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Sarı, Cenk; Baştuğ, Serdal; Erdoğan, Kemal Eşref; Bayram, Nihal Akar; Bilen, Emine; Akçay, Murat; Bozkurt, Engin

    2015-01-01

    Background Transcatheter aortic valve implantation (TAVI) is a minimally invasive, emerging therapy in surgically high risk, or inoperable patients. Parameters used for risk classification have some deficiencies in the selection of patients. The objective of this study is to evaluate the impact of TAVI on carbohydrate antigen 125 (CA125) and N-Terminal pro Brain-type Natriuretic Peptide (NT-proBNP) as biomarkers that have been used frequently in recent years, and also the relationship of these biomarkers to prognosis. Methods & Results Transcatheter aortic valve implantation was practiced on 31 patients in this study. Then, CA125 and NT-proBNP levels studied in patients prior to and after the TAVI were evaluated. The patients were also grouped in accordance with their left ventricular ejection fraction (LVEF) and CA125 levels (LVEF ≥ 40% and < 40%; CA125 ≤ 35 U/L and > 35 U/L). The TAVI operation was successfully performed in all patients. There was no in-hospital mortality and substantial improvement in functional capacity was detected at follow ups. In addition, a statistically significant decrease was detected in post-TAVI CA125 and NT-proBNP levels of all patients (CA125 83.8 ± 18.1 U/L vs. 64.3 ± 14.2 U/L, P = 0.008; NT-proBNP: 4633.6 ± 627.6 pg/mL vs. 2866.3 ± 536.8 pg/mL, P < 0.001). In groups divided according to the CA125 levels, there was also statistically significant post-TAVI decline in CA125 levels. Within CA125 > 35 U/L and LVEF < 40% groups, the permanent need for a pacemaker was required in one (3.2%) patient and mortality was observed in two (6.4%) patients after TAVI at follow up. Conclusions The results show that TAVI can be performed effectively and reliably in patients with high baseline levels of CA125 and NT-proBNP. These biomarkers are reduced substantially with TAVI, while high biomarker levels are associated with undesired events, and certainly, these biomarkers can be used for risk classifications in patient selection for TAVI

  1. Influence of Prostatic Edema on {sup 131}CS Permanent Prostate Seed Implants: A Dosimetric and Radiobiological Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kehwar, Than S., E-mail: kehwarts@upmc.ed; Jones, Heather A.; Huq, M. Saiful

    2011-06-01

    Purpose: To study the influence of prostatic edema on postimplant physical and radiobiological parameters using {sup 131}Cs permanent prostate seed implants. Methods and Materials: Thirty-one patients with early prostate cancer who underwent {sup 131}Cs permanent seed implantation were evaluated. Dose-volume histograms were generated for each set of prostate volumes obtained at preimplantation and postimplantion days 0, 14, and 28 to compute quality indices (QIs) and fractional doses at level x (FD{sub x}). A set of equations for QI, FD{sub x}, and biologically effective doses at dose level D{sub x} (BED{sub x}) were defined to account for edema changes with timemore » after implant. Results: There were statistically significant differences found between QIs of pre- and postimplant plans at day 0, except for the overdose index (ODI). QIs correlated with postimplant time, and FD{sub x} was found to increase with increasing postimplant time. With the effect of edema, BED at different dose levels showed less improvement due to the short half-life of {sup 131}Cs, which delivers about 85% of the prescribed dose before the prostate reaches its original volume due to dissipation of edema. Conclusions: Results of the study show that QIs, FD{sub x}, and BEDs at the level of D{sub x} changed from preneedle plans to postimplant plans and have statistically significant differences (p < 0.05), except for the ODI (p = 0.106), which suggests that at the time of {sup 131}C seed implantation, the effect of edema must be accounted for when defining the seed positions, to avoid the possibility of poor dosimetric and radiobiologic results for {sup 131}Cs seed implants.« less

  2. 125-mJ diode-pumped injection-seeded Ho:Tm:YLF laser.

    PubMed

    Yu, J; Singh, U N; Barnes, N P; Petros, M

    1998-05-15

    We describe a diode-pumped, room-temperature Ho:Tm:YLF power oscillator with an optical-to-optical efficiency of 0.03. A Q -switched output energy of as much as 125 mJ at 6 Hz with a pulse width of 170 ns was obtained. Single-frequency, nearly transform-limited operation of the laser was achieved by injection seeding. Laser performance as a function of laser rod temperature and pump intensity was also investigated. The high power and high beam quality of this laser make it well suited for use as a coherent wind lidar transmitter on a space platform.

  3. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis.

    PubMed

    Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Pellizzer, Eduardo Piza

    2014-12-01

    The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10, 12.5, 15 mm - crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-D models. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises' criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maximum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio=30.1% and C/I 1:1 to 1:1.5 ratio=46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio=30% and C/I 1:1 to 1:1.5 ratio=51.5%). Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Modified COMS Plaques for {sup 125}I and {sup 103}Pd Iris Melanoma Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, Rowan M., E-mail: rthomson@physics.carleton.c; Furutani, Keith M.; Pulido, Jose S.

    2010-11-15

    Purpose: Novel plaques are used to treat iris melanoma at the Mayo Clinic Rochester. The plaques are a modification of the Collaborative Ocular Melanoma Study (COMS) 22 mm plaque design with a gold alloy backing, outer lip, and silicone polymer insert. An inner lip surrounds a 10 mm diameter cutout region at the plaque center. Plaques span 360{sup o}, 270{sup o}, and 180{sup o} arcs. This article describes dosimetry for these plaques and others used in the treatment of anterior eye melanomas. Methods and Materials: The EGSnrc user-code BrachyDose is used to perform Monte Carlo simulations. Plaques and seeds aremore » fully modeled. Three-dimensional dose distributions for different plaque models, TG-43 calculations, and {sup 125}I (model 6711) and {sup 103}Pd (model 200) seeds are compared via depth-dose curves, tabulation of doses at points of interest, and isodose contours. Results: Doses at points of interest differ by up to 70% from TG-43 calculations. The inner lip reduces corneal doses. Matching plaque arc length to tumor extent reduces doses to eye regions outside the treatment area. Maintaining the same prescription dose, {sup 103}Pd offers lower doses to critical structures than {sup 125}I, with the exception of the sclera adjacent to the plaque. Conclusion: The Mayo Clinic plaques offer several advantages for anterior eye tumor treatments. Doses to regions outside the treatment area are significantly reduced. Doses differ considerably from TG-43 predictions, illustrating the importance of complete Monte Carlo simulations. Calculations take a few minutes on a single CPU, making BrachyDose sufficiently fast for routine clinical treatment planning.« less

  5. On-line I-/Te- separation for the AMS analysis of 125I

    NASA Astrophysics Data System (ADS)

    Charles, C. R. J.; Cornett, R. J.; Zhao, X.-L.; Litherland, A. E.; Kieser, W. E.

    2015-10-01

    The isobar separator for anions (ISA) was used together with a 3 MV tandem accelerator mass spectrometer (AMS) to demonstrate the real time (on-line) separation of Te- from I-. Following the ion source mass spectrometry and major retardation to tens of eV, the ISA uses a radiofrequency quadrupole (RFQ) ion guide to confine and direct I- and associated Te- isobar anions through a gas-reaction cell, where chemical reactions occur at eV energies with the electronegative gas NO2. Anions are subsequently reaccelerated out of the ISA to near original ion source extraction energies for AMS analysis. At 5 mTorr NO2 in the ISA gas-reaction cell, 125Te- was observed to be attenuated by a factor of ∼107 as compared to 127I- that did not experience significant (<50%) losses. A comparative test using 37Cl- and 32S- (having similar chemical properties to iodine and tellurium) showed a 32S- attenuation of >107 relative to 37Cl- under the same ISA-AMS conditions. The preferential destruction of Te- (and S-) at eV energies in the ISA is likely due to a larger favorable destruction cross-section with NO2. This study is the first demonstration of I-Te anion separation for AMS, and makes possible the use of 125I, free of the contaminant 125Te isobar after suitable sample purification, for future 129I/125I carrier-free analyses of natural samples at ultra-low trace levels.

  6. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.

    PubMed

    Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M

    2017-02-01

    BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  7. In vivo fate of 125I SS-B (La) injected into mice.

    PubMed Central

    Schrieber, L; Erhardt, C C; Melsom, R D; Venables, P J; McCarthy, D A; Mumford, P A; Horsfall, A C; Maini, R N

    1983-01-01

    The fate of the radiolabelled soluble cellular antigen SS-B (La) was compared with that of other 125I-labelled proteins of known molecular weight (MW) and electrostatic charge, following i.v. injection into BALB/c mice. The plasma half-life of 125I-SS-B was 3 min, while that of 125I-bovine serum albumin (similar MW and electrostatic charge) was 270 min. 125I-heat-aggregated IgG (MW greater than 1 x 10(6)) and 125I-7S human IgG (MW 168,000) had plasma half-lives of 40 min and greater than 300 min, respectively. Liver and kidney showed preferential uptake of 125I-SS-B, followed by a rapid decrease in radioactivity. During this time low MW, trichloroacetic acid (TCA) soluble, material appeared in urine. This suggests a specific uptake mechanism followed by a catabolic phase. These studies demonstrate that normal mice remove 125I-SS-B rapidly from the circulation and then degrade it. This rapid antigen elimination may protect against the induction of potentially harmful autoantibody responses. PMID:6832805

  8. Sci-Sat AM(2): Brachy-07: Tomosynthesis-based seed reconstruction in LDR prostate brachytherapy: A clinical study.

    PubMed

    Brunet-Benkhoucha, M; Verhaegen, F; Lassalle, S; Béliveau-Nadeau, D; Reniers, B; Donath, D; Taussky, D; Carrier, J-F

    2008-07-01

    To develop a tomosynthesis-based dose assessment procedure that can be performed after an I-125 prostate seed implantation, while the patient is still under anaesthesia on the treatment table. Our seed detection procedure involves the reconstruction of a volume of interest based on the backprojection of 7 seed-only binary images acquired over an angle of 60° with an isocentric imaging system. A binary seed-only volume is generated by a simple thresholding of the volume of interest. Seeds positions are extracted from this volume with a 3D connected component analysis and a statistical classifier that determines the number of seeds in each cluster of connected voxels. A graphical user interface (GUI) allows to visualize the result and to introduce corrections, if needed. A phantom and a clinical study (24 patients) were carried out to validate the technique. A phantom study demonstrated a very good localization accuracy of (0.4+/-0.4) mm when compared to CT-based reconstruction. This leads to dosimetric error on D90 and V100 of respectively 0.5% and 0.1%. In a patient study with an average of 56 seeds per implant, the automatic tomosynthesis-based reconstruction yields a detection rate of 96% of the seeds and less than 1.5% of false-positives. With the help of the GUI, the user can achieve a 100% detection rate in an average of 3 minutes. This technique would allow to identify possible underdosage and to correct it by potentially reimplanting additional seeds. A more uniform dose coverage could then be achieved in LDR prostate brachytherapy. © 2008 American Association of Physicists in Medicine.

  9. Pretreatment Nomogram to Predict the Risk of Acute Urinary Retention After I-125 Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roeloffzen, Ellen M., E-mail: e.m.a.roeloffzen@umcutrecht.nl; Vulpen, Marco van; Battermann, Jan J.

    Purpose: Acute urinary retention (AUR) after iodine-125 (I-125) prostate brachytherapy negatively influences long-term quality of life and therefore should be prevented. We aimed to develop a nomogram to preoperatively predict the risk of AUR. Methods: Using the preoperative data of 714 consecutive patients who underwent I-125 prostate brachytherapy between 2005 and 2008 at our department, we modeled the probability of AUR. Multivariate logistic regression analysis was used to assess the predictive ability of a set of pretreatment predictors and the additional value of a new risk factor (the extent of prostate protrusion into the bladder). The performance of the finalmore » model was assessed with calibration and discrimination measures. Results: Of the 714 patients, 57 patients (8.0%) developed AUR after implantation. Multivariate analysis showed that the combination of prostate volume, IPSS score, neoadjuvant hormonal treatment and the extent of prostate protrusion contribute to the prediction of AUR. The discriminative value (receiver operator characteristic area, ROC) of the basic model (including prostate volume, International Prostate Symptom Score, and neoadjuvant hormonal treatment) to predict the development of AUR was 0.70. The addition of prostate protrusion significantly increased the discriminative power of the model (ROC 0.82). Calibration of this final model was good. The nomogram showed that among patients with a low sum score (<18 points), the risk of AUR was only 0%-5%. However, in patients with a high sum score (>35 points), the risk of AUR was more than 20%. Conclusion: This nomogram is a useful tool for physicians to predict the risk of AUR after I-125 prostate brachytherapy. The nomogram can aid in individualized treatment decision-making and patient counseling.« less

  10. [Degradation of prolactin 125-I in the mammary gland of lactating rats].

    PubMed

    Marinchenko, G V; Taranenko, A G

    1977-01-01

    Prolactin-125I metabolism in the mammary gland of lactating rats was studied; the hormone was injected intraperitoneally. Radioactive products accumulated by the mammary gland tissue were extracted with isotonic medium. Tissue extracts, blood serum and milk were analyzed by gel filtration on Sephadex G-200. The Blood displayed a gradual reduction of prolactin-125I content as a result of its splitting in the organs and binding with blood proteins; as to the mammary gland--there occurred accumulation of the products of prolactin-125I degradation. Some hormone was inactivated losing immunological properties without any significant changes in the molecular weight. Besides, the mammary gland displayed an intensive accumulation of the products of prolactin-125I splitting in the other organs and in the gland proper. Radioactivity accumulated in the milk was mainly referred to the products of prolactin-125I degradation. There was also shown the presence of immunologically active prolactin-125I in the milk.

  11. Cell Seeding Densities in Autologous Chondrocyte Implantation Techniques for Cartilage Repair.

    PubMed

    Foldager, Casper Bindzus; Gomoll, Andreas H; Lind, Martin; Spector, Myron

    2012-04-01

    Cartilage repair techniques have been among the most intensively investigated treatments in orthopedics for the past decade, and several different treatment modalities are currently available. Despite the extensive research effort within this field, the generation of hyaline cartilage remains a considerable challenge. There are many parameters attendant to each of the cartilage repair techniques that can affect the amount and types of reparative tissue generated in the cartilage defect, and some of the most fundamental of these parameters have yet to be fully investigated. For procedures in which in vitro-cultured autologous chondrocytes are implanted under a periosteal or synthetic membrane cover, or seeded onto a porous membrane or scaffold, little is known about how the number of cells affects the clinical outcome. Few published clinical studies address the cell seeding density that was employed. The principal objective of this review is to provide an overview of the cell seeding densities used in cell-based treatments currently available in the clinic for cartilage repair. Select preclinical studies that have informed the use of specific cell seeding densities in the clinic are also discussed.

  12. 33 CFR 159.125 - Visible floating solids: Type I devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Visible floating solids: Type I devices. 159.125 Section 159.125 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.125...

  13. SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mashouf, S; University of Toronto, Dept. of Radiation Oncology, Toronto, ON; Ravi, A

    Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH).more » The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of

  14. Well-ionization chamber response relative to NIST air-kerma strength standard for prostate brachytherapy seeds.

    PubMed

    Mitch, M G; Zimmerman, B E; Lamperti, P J; Seltzer, S M; Coursey, B M

    2000-10-01

    The response of well-ionization chambers to the emissions of 103Pd and 125I radioactive seed sources used in prostate cancer brachytherapy has been measured. Calibration factors relating chamber response (current or dial setting) to measured air-kerma strength have been determined for seeds from nine manufacturers, each with different designs. Variations in well-ionization chamber response relative to measured air-kerma strength have been observed because of differences in the emitted energy spectrum due to both the radionuclide support material (125I seeds) and the mass ratio of 103Pd to 102Pd (103Pd seeds). Obtaining accurate results from quality assurance measurements using well-ionization chambers at a therapy clinic requires knowledge of such differences in chamber response as a function of seed design.

  15. Intra-operative Iodine-125 prostatic implant following bilateral pelvic lymphadenectomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwong, E.W.H.; Huh, S.H.; Nobler, M.P.

    Sixty-five patients with prostatic adenocarcinoma Stages B and C were treated with intraoperative Iodine-125 prostatic implantation following bilateral pelvic lymphadenectomy. Pelvic nodal metastases were found in 31% of the patients. All the patients have been followed for a period of 1 1/2 to 6 years. Serial digital rectal examination revealed complete regression of the palpable disease in 15% of the patients at 6 months, 47% at 1 year, and 87% at 2 years. Post-operative complications were also evaluated: 13% of the patients became sexually impotent, 11% had impaired potency after the procedure, and 26% of patients complained of dry ejaculation;more » and 17% developed scrotal and/or penile swelling, which persisted up to 14 months, but usually subsided within 5 months. Two patients developed local recurrence.« less

  16. Alpha 1-Adrenoceptor Blocker May Improve Not Only Voiding But Also Storage Lower Urinary Tract Symptoms Caused by 125I Brachytherapy for Prostate Cancer

    PubMed Central

    Aoki, Yoshitaka; Ito, Hideaki; Miwa, Yoshiji; Akino, Hironobu; Shioura, Hiroki; Kimura, Hirohiko; Yokoyama, Osamu

    2014-01-01

    Purpose. To assess changes in lower urinary tract symptoms (LUTS) within 1 year after brachytherapy in patients receiving alpha 1-adrenoceptor antagonists. Methods. We retrospectively evaluated 116 patients who underwent 125I prostate brachytherapy in our institute. Seventy-one patients were treated with a combination of external beam radiation therapy and brachytherapy. Alpha 1-adrenoceptor antagonists were prescribed to all patients after brachytherapy. International Prostate Symptom Score (IPSS) forms and postvoid residual urine volume were recorded at all follow-up visits. Results. Forty-nine patients were given tamsulosin hydrochloride, 32 were given silodosin hydrochloride, and 35 were given naftopidil for up to 6 months after seed implantation. Patients given tamsulosin or naftopidil tended to show a higher peak IPSS and slower recovery to baseline values than those given silodosin. The patients given naftopidil showed an insufficient recovery in storage symptoms in naftopidil group in comparison with tamsulosin group at 3 months and with silodosin group at 6 and 9 months. Conclusions. In the management of LUT after brachytherapy, silodosin may provide a more favorable improvement. Silodosin and tamsulosin may have an advantage in improving not only voiding but also storage lower urinary tract symptoms after brachytherapy. PMID:25006516

  17. Effect of 1,25(OH)2 vitamin D3 on cytokine production by endometrial cells of women with repeated implantation failure.

    PubMed

    Rajaei, Samira; Mirahmadian, Mahroo; Jeddi-Tehrani, Mahmood; Tavakoli, Maryam; Zonoobi, Mojdeh; Dabbagh, Ali; Zarnani, Amir Hassan

    2012-11-01

    Repeated implantation failure (RIF) is a worldwide health problem that imposes a great deal of cost on patients and health care system. Vitamin D(3) has been proposed to have positive impact on the process of implantation. The present study was performed to compare the effect of 1,25-dihydroxy vitamin D(3) (1,25(OH)(2)D(3)) on cytokine production by endometrial cells of women with RIF and healthy fertile controls. Whole endometrial cells (WECs) and endometrial stromal cells (ESCs) from RIF and normal fertile women were treated with 1,25(OH)(2)D(3). The levels of IL-10, TGF-β, IFNγ, Il-6, IL-8 and IL-17 in culture supernatants were assayed by ELISA. Also, ability of the cells from both groups to produce 1,25(OH)(2)D(3) was evaluated and compared. 1,25(OH)(2)D(3) down-regulated cytokine production in WECs from both groups except for IL-8 which was upraised. Similar trends were also observed in ESCs except up-regulation of TGF-β in RIF group. Endometrial cells of both groups had comparable capacity to produce 1,25(OH)(2)D(3). Based on the minimal differential immunoregulatory effect of vitamin D(3) on endometrial cells from RIF and control women, it may be suggested that circulating levels of maternal vitamin D(3) be the subject of further investigation.

  18. Solid-phase receptor binding assay for /sup 125/I-hCG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bortolussi, M.; Selmin, O.; Colombatti, A.

    1987-01-01

    A solid-phase radioligand-receptor assay (RRA) to measure the binding of /sup 125/I-labelled human chorionic gonadotropin (/sup 125/I-hCG) to target cell membranes has been developed. The binding of /sup 125/I-hCG to membranes immobilized on the wells of microtitration plates reached a maximum at about 3 hours at 37 degrees C, was saturable, displayed a high affinity (Ka = 2.4 X 10(9) M-1) and was specifically inhibited by unlabelled hCG. In comparison with RRAs carried out with membranes in suspension, the solid-phase RRA is significantly simpler and much faster to perform as it avoids centrifugation or filtration procedures. The solid-phase RRA wasmore » adapted profitably to process large numbers of samples at the same time. It proved particularly useful as a screening assay to detect anti-hCG monoclonal antibodies with high inhibitory activity for binding of /sup 125/I-hCG to its receptors.« less

  19. WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, D; Usmani, N; Sloboda, R

    Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogatemore » urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to

  20. [Effect of image fusion technology of radioactive particles implantation before and after the planning target and dosimetry].

    PubMed

    Jiang, Y L; Yu, J P; Sun, H T; Guo, F X; Ji, Z; Fan, J H; Zhang, L J; Li, X; Wang, J J

    2017-08-01

    Objective: To compare the post-implant target volumes and dosimetric evaluation with pre-plan, the gross tumor volume(GTV) by CT image fusion-based and the manual delineation of target volume in CT guided radioactive seeds implantation. Methods: A total of 10 patients treated under CT-guidance (125)I seed implantation during March 2016 to April 2016 were analyzed in Peking University Third Hospital.All patients underwent pre-operative CT simulation, pre-operative planning, implantation seeds, CT scanning after seed implantation and dosimetric evaluation of GTV.In every patient, post-implant target volumes were delineated by both two methods, and were divided into two groups. Group 1: image fusion pre-implantation simulation and post-operative CT image, then the contours of GTV were automatically performed by brachytherapy treatment planning system; Group 2: the contouring of the GTV on post-operative CT image were performed manually by three senior radiation oncologists independently. The average of three data was sets. Statistical analyses were performed using SPSS software, version 3.2.0. The paired t -test was used to compare the target volumes and D(90) parameters in two modality. Results: In Group 1, average volume of GTV in post-operation group was 12-167(73±56) cm(3). D(90) was 101-153 (142±19)Gy. In Group 2, they were 14-186(80±58)cm(3) and 96-146(122±16) Gy respectively. In both target volumes and D(90), there was no statistical difference between pre-operation and post-operation in Group 1.The D(90) was slightly lower than that of pre-plan group, but there was no statistical difference ( P =0.142); in Group 2, between pre-operation and post-operation group, there was a significant statistical difference in the GTV ( P =0.002). The difference of D(90) was similarly ( P <0.01). Conclusion: The method of delineation of post-implant GTV through fusion pre-implantation simulation and post-operative CT scan images, the contours of GTV are automatically

  1. SLM Produced Porous Titanium Implant Improvements for Enhanced Vascularization and Osteoblast Seeding

    PubMed Central

    Matena, Julia; Petersen, Svea; Gieseke, Matthias; Kampmann, Andreas; Teske, Michael; Beyerbach, Martin; Murua Escobar, Hugo; Haferkamp, Heinz; Gellrich, Nils-Claudius; Nolte, Ingo

    2015-01-01

    To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM) enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL) coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF), high mobility group box 1 (HMGB1) and chemokine (C-X-C motif) ligand 12 (CXCL12). As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI). Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release. PMID:25849656

  2. SLM produced porous titanium implant improvements for enhanced vascularization and osteoblast seeding.

    PubMed

    Matena, Julia; Petersen, Svea; Gieseke, Matthias; Kampmann, Andreas; Teske, Michael; Beyerbach, Martin; Murua Escobar, Hugo; Haferkamp, Heinz; Gellrich, Nils-Claudius; Nolte, Ingo

    2015-04-02

    To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM) enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL) coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF), high mobility group box 1 (HMGB1) and chemokine (C-X-C motif) ligand 12 (CXCL12). As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI). Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release.

  3. Long reach DWDM-PON with 12.5 GHz channel spacing based on comb source seeding

    NASA Astrophysics Data System (ADS)

    Zhou, Zhao; Nie, Hai-tao; Wang, Yao-jun

    2016-07-01

    A long reach dense wavelength division multiplexing passive optical network (DWDM-PON) with 12.5 GHz channel spacing is proposed and experimentally demonstrated. An optical frequency comb source is used to provide the multiwavelength seeding light, while reflective semiconductor optical amplifiers (RSOAs) are installed in both optical line terminal (OLT) and optical network units (ONUs) as colorless transmitter. The experimental results show that the bidirectional transmission for 1.2 Gbit/s data rate is achieved over 80 km single mode fiber (SMF).

  4. Sci-Sat AM(2): Brachy-05: Dosimetry effects of the TG-43 approximations for two iodine seeds in LDR brachytherapy.

    PubMed

    Furstoss, C; Bertrand, M J; Poon, E; Reniers, B; Pignol, J P; Carrier, J F; Beaulieu, L; Verhaegen, F

    2008-07-01

    This work consists of studying the interseed and tissue composition effects for two model iodine seeds: the IBt Interseed-125 and the 6711 model seed. Three seeds were modeled with the MCNP MC code in a water sphere to evaluate the interseed effect. The dose calculated at different distances from the centre was compared to the dose summed when the seeds were simulated separately. The tissue composition effect was studied calculating the radial dose function for different tissues. Before carrying out post-implant studies, the absolute dose calculated by MC was compared to experiment results: with LiF TLDs in an acrylic breast phantom and with an EBT Gafchromic film placed in a water tank. Afterwards, the TG-43 approximation effects were studied for a prostate and breast post-implant. The interseed effect study shows that this effect is more important for model 6711 (15%) than for IBt (10%) due to the silver rod in 6711. For both seed models the variations of the radial dose function as a function of the tissue composition are quasi similar. The absolute dose comparisons between MC calculations and experiments give good agreement (inferior to 3% in general). For the prostate and breast post-implant studies, a 10% difference between MC calculations and the TG-43 is found for both models of seeds. This study shows that the differences in dose distributions between TG43 and MC are quite similar for the two models of seeds and are about 10% for the studied post-implant treatments. © 2008 American Association of Physicists in Medicine.

  5. Synthesis of [{sup 125}I]iodoDPA-713: A new probe for imaging inflammation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Haofan; Pullambhatla, Mrudula; Guilarte, Tomas R.

    2009-11-06

    [{sup 125}I]IodoDPA-713 [{sup 125}I]1, which targets the translocator protein (TSPO, 18 kDa), was synthesized in seven steps from methyl-4-methoxybenzoate as a tool for quantification of inflammation in preclinical models. Preliminary in vitro autoradiography and in vivo small animal imaging were performed using [{sup 125}I]1 in a neurotoxicant-treated rat and in a murine model of lung inflammation, respectively. The radiochemical yield of [{sup 125}I]1 was 44 {+-} 6% with a specific radioactivity of 51.8 GBq/{mu}mol (1400 mCi/{mu}mol) and >99% radiochemical purity. Preliminary studies showed that [{sup 125}I]1 demonstrated increased specific binding to TSPO in a neurotoxicant-treated rat and increased radiopharmaceutical uptakemore » in the lungs of an experimental inflammation model of lung inflammation. Compound [{sup 125}I]1 is a new, convenient probe for preclinical studies of TSPO activity.« less

  6. Radioimmunoassay of salivary cyclosporine with use of /sup 125/I-labeled cyclosporine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, J.E.; Lam, S.F.; McGaw, W.T.

    1988-08-01

    We prepared /sup 125/I-labeled cyclosporine (/sup 125/I-CS) by modifying the procedure of Mahoney and Orf and characterized it with regards to maximal immunoreactivity (greater than 90%), trichloroacetic acid precipitability (greater than 90%), and stability (90% immunoreactive after five half-lives of /sup 125/I). For a particular preparation of /sup 125/I-CS, we estimated its immunoreaction concentration (50 pmol/L) and the equilibrium constant for its reaction with Sandoz polyclonal antiserum (K = 3.9 X 10(9) L/mol). By substituting /sup 125/I-CS as tracer in the Sandoz radioimmunoassay and by modifying other aspects of the assay, we developed a procedure that is sufficiently sensitive (0.34more » micrograms/L) to allow measurement of trough (lowest inter-dose) cyclosporine concentrations in parotid saliva. Of 38 kidney-transplant patients, 35 had measurable concentrations in saliva (mean 8.3, SD 5.2 micrograms/L), and these correlated moderately with paired serum concentrations (r = 0.68, P less than 0.001). We believe that measurement of salivary cyclosporine may offer a simple way of estimating the free fraction of the drug in serum or plasma.« less

  7. Radioiodination of scorpion and snake toxins. [/sup 125/I, /sup 127/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rochat, H.; Tessier, M.; Miranda, F.

    1977-10-01

    Several scorpion and snake toxins were radioiodinated using the lactoperoxydase method of (/sup 125/I)iodide oxidation. Two techniques of labeling were set up: Using carrier-free Na/sup 125/I and 5 ..mu..g of toxin, about one iodine atom was incorporated per mole of protein without loss of toxicity. Specific radioactivities about 2,000 Ci/mmol (280 ..mu..Ci/..mu..g) were obtained. The modified toxin, purified by immunoprecipitation with an antiserum prepared against the native toxin, was obtained in a short time (4 hr), with a good yield (50 to 80%), and in a small volume (1 ml). Using Na/sup 127/I traced with Na /sup 125/I and largermore » amounts (200 ..mu..g) of toxin, more than one iodine atom was incorporated per mole of protein without loss of activity. Lower specific radioactivities (1 to 1.5 Ci/mmol) were obtained. The iodinated toxins were purified by gel filtration of the radioiodination mixtures on a column made of two layers of Sephadex (G-15 and G-50). The modified proteins were extensively analyzed by paper electrophoresis and polyacrylamide gel electrophoresis. Their content of monoiodotyrosine and diiodotyrosine was estimated and, in the case of toxin I of Androctonus australis Hector, it was possible to follow the iodination rate of its three tyrosine residues by automatic Edman degradation. The mode of purification of the iodinated scorpion toxins affects their behavior on molecular sieving on Sephadex G-50 and on electrophoresis on polyacrylamide gel. The results are discussed.« less

  8. Repair of Avascular Meniscus Tears with Electrospun Collagen Scaffolds Seeded with Human Cells

    PubMed Central

    Baek, Jihye; Sovani, Sujata; Glembotski, Nicholas E.; Du, Jiang; Jin, Sungho; Grogan, Shawn P.

    2016-01-01

    The self-healing capacity of an injured meniscus is limited to the vascularized regions and is especially challenging in the inner avascular regions. As such, we investigated the use of human meniscus cell-seeded electrospun (ES) collagen type I scaffolds to produce meniscal tissue and explored whether these cell-seeded scaffolds can be implanted to repair defects created in meniscal avascular tissue explants. Human meniscal cells (derived from vascular and avascular meniscal tissue) were seeded on ES scaffolds and cultured. Constructs were evaluated for cell viability, gene expression, and mechanical properties. To determine potential for repair of meniscal defects, human meniscus avascular cells were seeded and cultured on aligned ES collagen scaffolds for 4 weeks before implantation. Surgical defects resembling “longitudinal tears” were created in the avascular zone of bovine meniscus and implanted with cell-seeded collagen scaffolds and cultured for 3 weeks. Tissue regeneration and integration were evaluated by histology, immunohistochemistry, mechanical testing, and magentic resonance imaging. Ex vivo implantation with cell-seeded collagen scaffolds resulted in neotissue that was significantly better integrated with the native tissue than acellular collagen scaffolds or untreated defects. Human meniscal cell-seeded ES collagen scaffolds may therefore be useful in facilitating meniscal repair of avascular meniscus tears. PMID:26842062

  9. Evaluation of two (125)I-radiolabeled acridine derivatives for Auger-electron radionuclide therapy of melanoma.

    PubMed

    Gardette, Maryline; Viallard, Claire; Paillas, Salomé; Guerquin-Kern, Jean-Luc; Papon, Janine; Moins, Nicole; Labarre, Pierre; Desbois, Nicolas; Wong-Wah-Chung, Pascal; Palle, Sabine; Wu, Ting-Di; Pouget, Jean-Pierre; Miot-Noirault, Elisabeth; Chezal, Jean-Michel; Degoul, Francoise

    2014-08-01

    We previously selected two melanin-targeting radioligands [(125)I]ICF01035 and [(125)I]ICF01040 for melanoma-targeted (125)I radionuclide therapy according to their pharmacological profile in mice bearing B16F0 tumors. Here we demonstrate in vitro that these compounds present different radiotoxicities in relation to melanin and acidic vesicle contents in B16F0, B16F0 PTU and A375 cell lines. ICF01035 is effectively observed in nuclei of achromic (A375) melanoma or in melanosomes of melanized melanoma (B16F0), while ICF01040 stays in cytoplasmic vesicles in both cells. [(125)I]ICF01035 induced a similar survival fraction (A50) in all cell lines and led to a significant decrease in S-phase cells in amelanotic cell lines. [(125)I]ICF01040 induced a higher A50 in B16 cell lines compared to [(125)I]ICF01035 ones. [(125)I]ICF01040 induced a G2/M blockade in both A375 and B16F0 PTU, associated with its presence in cytoplasmic acidic vesicles. These results suggest that the radiotoxicity of [(125)I]ICF01035 and [(125)I]ICF01040 are not exclusively reliant on DNA alterations compatible with γ rays but likely result from local dose deposition (Auger electrons) leading to toxic compound leaks from acidic vesicles. In vivo, [(125)I]ICF01035 significantly reduced the number of B16F0 lung colonies, enabling a significant increase in survival of the treated mice. Targeting melanosomes or acidic vesicles is thus an option for future melanoma therapy.

  10. Intracellular processing of epidermal growth factor. I. Acidification of 125I-epidermal growth factor in intracellular organelles.

    PubMed

    Matrisian, L M; Planck, S R; Magun, B E

    1984-03-10

    We previously reported that 125I-labeled epidermal growth factor is processed intracellularly to acidic macromolecules in Rat-1 fibroblasts. The present study defines the precursor-product relationship and localization of the processing steps to subcellular organelles by the use of a single isoelectric species of 125I-epidermal growth factor and Percoll gradient fractionation. The native pI 4.55 125I-epidermal growth factor was rapidly processed to a pI 4.2 species on or near the cell surface and in organelles corresponding to clathrin-coated vesicles, Golgi, and endoplasmic reticulum. This species was then processed to a pI 4.35 species in similar organelles. The pI 4.2 and 4.35 species were converted to a pI 4.0 species in dense, lysosome-like organelles. This species was ultimately degraded and exocytosed from the cell as low molecular weight products.

  11. Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, D; Usmani, N; Sloboda, R

    The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used tomore » infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage.« less

  12. Experimental measurements and Monte Carlo simulations of dose perturbation around a nonradioactive brachytherapy seed due to 6- and 18-MV photons.

    PubMed

    Steinman, James Paul; Bakhtiari, Mohammad; Malhotra, Harish Kumar

    2012-01-01

    Radioactive seeds used in permanent prostate brachytherapy are composed of high-Z metals and may exceed 100 in a patient. If supplemental external beam treatment is administered afterward, the seeds may cause substantial dose perturbation, which is being investigated in this article. Film measurements using 6-MV beam were primarily carried out using Kodak XV2 film layered above and below a nonradioactive iodine-125 ((125)I) seed. Monte Carlo simulations were carried out using DOSXYZnrc. Other experimental comparisons looked at changing beam energy, depth, and field size, including two opposing fields' pair. Effect of multiple seeds spatially spaced 0.5cm vertically was also studied. For a single (125)I seed, on XV film, there is a localized dose enhancement of 6.3% upstream and -10.9% downstream. With two opposing fields, a cold spot around the seed of ∼3% was noticed. Increasing beam energy and field size decreased the magnitude of this effect, whereas the effect was found to increase with the increasing Z of material. DOSXYZnrc and EBT-2 film verified maximum dose enhancement of +15% upstream and -20% downstream of the (125)I seed surface. In general, the dose perturbation because of the seeds was spatially limited to ∼2mm upstream and ∼5mm downstream to the incident beam. Similar to other heterogeneities, the seeds perturbation depends on incident beam energy, field size, and its Z. With multiple seeds spatially apart and multiple radiation fields routinely used in external beam radiotherapy, the cumulative effect may not result in clinically significant dose perturbation. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Sci-Thur PM – Brachytherapy 02: Positional accuracy in Pd-103 permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederick, Amy; Watt, Elizabeth; Peacock, Michael

    Purpose: This retrospective study aims to quantify the positional accuracy of seed delivery in permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC). Methods: Treatment planning and post-implant CT scans for 5 patients were rigidly registered using the MIM Symphony™ software (MIM Software, Cleveland, OH) and used to evaluate differences between planned and implanted seed positions. Total and directional seed displacements were calculated for each patient in a clinically relevant ‘needle coordinate system’, defined relative to the angle of fiducial needle insertion. Results: The overall average total seed displacement was 10±8 mm. Systematic seed displacements weremore » observed in individual patients and the magnitude and direction of these offsets varied among patients. One patient showed a significant directional seed displacement in the shallow-deep direction compared with the other four patients. With the exception of this one patient outlier, no significant systematic directional displacements in the needle coordinate system were observed for this cohort; the average directional displacements were −1±5 mm, 2±3 mm, and −2±4 mm in the shallow-deep, up-down, and right-left directions respectively. Conclusion: With the exception of one patient outlier, the magnitude of seed displacements were relatively consistent among patients. The results indicate that the shallow-deep direction possesses the largest uncertainty for the seed delivery method used at the TBCC. The relatively large uncertainty in seed placement in this direction is expected, as this is the direction of needle insertion. Further work will involve evaluating deflections of delivered needle tracks from their planned positions.« less

  14. SU-F-T-40: Can CBCT Images Be Used for Volume Studies of Prostate Seed Implants for Boost Treatment?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H; Lee, S; Diwanji, T

    Purpose: In our clinic, the planning CT is used for definitive and boost low-dose-rate (LDR) brachytherapy treatments to determine the ultrasound volume in the operating room (OR) at the time of the implant. While the CT overestimation of OR volume is known, a larger estimation discrepancy has been observed for boost treatments. A possible reason is the prostate size reduction during EBRT for boost patients. Since cone-beam CT (CBCT) is often used as routine imaging guidance of EBRT, this prostate volume change may be captured. This study investigates if CBCT taken during EBRT includes the volume change information and thereforemore » beats CT in estimating the prostate OR volumes. Methods: 9 prostate patients treated with EBRT (45Gy in 1.8Gy per fractions to the whole pelvis) and I-125 seed implants (108Gy) were involved in this study. During EBRT, CBCT image guidance was performed on a weekly basis. For each patient, the prostate volumes on the first and the last available CBCT images were manually contoured by a physician. These volumes were then compared to each other and with the contoured volumes from the planning CT and from the ultrasound images in the OR. Results: The first and the last CBCT images did not show significant prostate volume change. Their average +/− standard deviation of prostate volumes were 24.4cc+/−14.6cc and 29.9cc+/−16.1cc, respectively (T-test p=0.68). The ratio of the OR volume to the last CBCT (0.71+/−0.21) was not significantly different from the ratio of OR volumes to the planning CT (0.61+/−0.13) (p=0.25). Conclusion: In this study, CBCT does not show significant prostate volume changes during EBRT. CBCT and CT volumes are quite consistent and no improvement of volume estimation using CBCT is observed. The advantage of CBCT as a replacement of CT for volume study of boost LDR brachytherapy is limited.« less

  15. Ectopic bone formation in nude rats using human osteoblasts seeded poly(3)hydroxybutyrate embroidery and hydroxyapatite-collagen tapes constructs.

    PubMed

    Mai, Ronald; Hagedorn, Manolo Gunnar; Gelinsky, Michael; Werner, Carsten; Turhani, Dritan; Späth, Heike; Gedrange, Tomas; Lauer, Günter

    2006-09-01

    The aim of this study was to evaluate the ectopic bone formation using tissue engineered cell-seeded constructs with two different scaffolds and primary human maxillary osteoblasts in nude rats over an implantation period of up to 96 days. Collagen I-coated Poly(3)hydroxybutyrate (PHB) embroidery and hydroxyapatite (HAP) collagen tapes were seeded with primary human maxillary osteoblasts (hOB) and implanted into athymic rnu/run rats. A total of 72 implants were placed into the back muscles of 18 rats. 24, 48 and 96 days after implantation, histological and histomorphometric analyses were made. The osteoblastic character of the cells was confirmed by immunocytochemistry and RT-PCR for osteocalcin. Histological analysis demonstrated that all cell-seeded constructs induced ectopic bone formation after 24, 48 and 96 days of implantation. There was more mineralized tissue in PHB constructs than in HAP-collagen tapes (at day 24; p < 0.05). Bone formation decreased with the increasing length of the implantation period. Osteocalcin expression verified the osteoblastic character of the cell-seeded constructs after implantation time. No bone formation and no osteocalcin expression were found in the control groups. Cell-seeded constructs either with PHB embroidery or HAP-collagen tapes can induce ectopic bone formation. However, the amount of bone formed decreased with increasing length of implantation.

  16. Radioimmunoassay for etorphine in horses with a /sup 125/I analog of etorphine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tai, C.L.; Wang, C.; Weckman, T.J.

    1988-05-01

    To improve the sensitivity and specificity of screening for etorphine in horses, an /sup 125/I-labeled etorphine analog was synthesized and an antibody to etorphine was raised in rabbits. A radioimmunoassay (RIA) for etorphine was developed, using these reagents. Bound and free /sup 125/I-labeled etorphine was separated by a double-antibody method that reduced interference from materials associated with equine urine. The /sup 125/I-labeled etorphine binding was rarely greater than 250 pg of background etorphine equivalents/ml in raw urine and was 100 pg/ml in hydrolyzed urine. The /sup 125/I-RIA was capable of detecting etorphine equivalents in urine above these background values. Etorphinemore » equivalents were detected in equine urine samples for about 7 days after 4 mares were dosed with 0.22 microgram of etorphine/kg of body weight, IV. The stability of etorphine in urine from these mares was evaluated. Urine from these dosed mares was held in constant -20 C storage, and aliquots were repeatedly frozen and thawed. When analyzed for etorphine equivalents using an /sup 125/I-RIA, etorphine and its metabolites in urine samples were stable for less than or equal to 38 days if continuously frozen and also were resistant to repeated freezing and thawing.« less

  17. Potential risk of acute toxicity induced by AgI cloud seeding on soil and freshwater biota.

    PubMed

    Fajardo, C; Costa, G; Ortiz, L T; Nande, M; Rodríguez-Membibre, M L; Martín, M; Sánchez-Fortún, S

    2016-11-01

    Silver iodide is one of the most common nucleating materials used in cloud seeding. Previous cloud seeding studies have concluded that AgI is not practically bioavailable in the environment but instead remains in soils and sediments such that the free Ag amounts are likely too low to induce a toxicological effect. However, none of these studies has considered the continued use of this practice on the same geographical areas and thus the potential cumulative effect of environmental AgI. The aim of this study is to assess the risk of acute toxicity caused by AgI exposure under laboratory conditions at the concentration expected in the environment after repeated treatments on selected soil and aquatic biota. To achieve the aims, the viability of soil bacteria Bacillus cereus and Pseudomonas stutzeri and the survival of the nematode Caenorhabditis elegans exposed to different silver iodide concentrations have been evaluated. Freshwater green algae Dictyosphaerium chlorelloides and cyanobacteria Microcystis aeruginosa were exposed to silver iodide in culture medium, and their cell viability and photosynthetic activity were evaluated. Additionally, BOD5 exertion and the Microtox® toxicity test were included in the battery of toxicological assays. Both tests exhibited a moderate AgI adverse effect at the highest concentration (12.5µM) tested. However, AgI concentrations below 2.5µM increased BOD5. Although no impact on the growth and survival endpoints in the soil worm C. elegans was recorded after AgI exposures, a moderate decrease in cell viability was found for both of the assessed soil bacterial strains at the studied concentrations. Comparison between the studied species showed that the cyanobacteria were more sensitive than green algae. Exposure to AgI at 0.43μM, the reference value used in monitoring environmental impact, induced a significant decrease in photosynthetic activity that is primarily associated with the respiration (80% inhibition) and, to a lesser

  18. A Dose–Response Analysis of Biochemical Control Outcomes After {sup 125}I Monotherapy for Patients With Favorable-Risk Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp; Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo; Yorozu, Atsunori

    Purpose: To define the optimal dose for {sup 125}I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity. Methods and Materials: Between 2003 and 2009, 683 patients with prostate cancer were treated with {sup 125}I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dosemore » effects on biochemical control and toxicity. Results: The 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant. Conclusions: Improvements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.« less

  19. [Dosimetry verification of radioactive seed implantation with 3D printing template and CT guidance for paravertebral/retroperitoneal malignant tumor].

    PubMed

    Ji, Z; Jiang, Y L; Guo, F X; Peng, R; Sun, H T; Fan, J H; Wang, J J

    2017-04-04

    Objective: To compare the dose distributions of postoperative plans with preoperative plans for seeds implantations of paravertebral/retroperitoneal tumors assisted by 3D printing guide template and CT guidance, explore the effects of the technology for seeds implantations in dosimetry level and provide data support for the optimization and standardization in seeds implantation. Methods: Between December 2015 and July 2016, a total of 10 patients with paravertebral/retroperitoneal tumors (12 lesions) received 3D printing template assist radioactive seeds implantations in department of radiation oncology of Peking University Third Hospital, and included in the study. The diseases included cervical cancer, kidney cancer, abdominal stromal tumor, leiomyosarcoma of kidney, esophageal cancer and carcinoma of ureter. The prescribed doses was 110-150 Gy. All patients received preoperative planning design, individual template design and production, and the dose distribution of postoperative plan was compared with preoperative plan. Dose parameters including D(90), MPD, V(100), V(150,)conformal index(CI), EI of target volume and D(2cc) of organs at risk (spinal cord, aorta, kidney). Statistical software was SPSS 19.0 and statistical method was non-parameters Wilcoxon symbols test. Results: A total of 10 3D printing templates were designed and produced which were including 12 treatment areas.The mean D(90) of postoperative target area (GTV) was 131.1 (97.8-167.4 Gy) Gy. The actual seeds number of post operation increased by 3 to 12 in 5 cases (42.0%). The needle was well distributed. For postoperative plans, the mean D(90,)MPD, V(100,)V(150) was 131.1 Gy, 69.3 Gy, 90.2% and 65.2%, respectively, and which was 140.2 Gy, 65.6 Gy, 91.7% and 26.8%, respectively, in preoperative plans. This meant that the actual dose of target volume was slightly lower than preplanned dose, and the high dose area of target volume was larger than preplanned range, but there was no statistical

  20. Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mashouf, Shahram; Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario; Fleury, Emmanuelle

    Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43more » dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.« less

  1. Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning.

    PubMed

    Mashouf, Shahram; Fleury, Emmanuelle; Lai, Priscilla; Merino, Tomas; Lechtman, Eli; Kiss, Alex; McCann, Claire; Pignol, Jean-Philippe

    2016-03-15

    The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V100 and V90 are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Prophylactic urethral stenting with Memokath® 028SW in prostate cancer patients undergoing prostate 125I seed implants: phase I/II study

    PubMed Central

    Chao, Samuel T.; Angermeier, Kenneth; Klein, Eric A.; Reddy, Chandana A.; Ulchaker, James C.; Stephenson, Andrew; Campbell, Steven

    2011-01-01

    Purpose To study the feasibility/toxicity of urethral stenting with the Memokath® 028SW stent in patients undergoing prostate implant (PI) for prostate adenocarcinoma. Material and methods An Investigational Device Exemption from the Food and Drug Administration (FDA) and institutional review board (IRB) approval were obtained. Twenty patients enrolled. Baseline American Urological Association (AUA) score was obtained prior to PI. Follow-up information was obtained with weekly phone calls for the first 12 weeks and biweekly calls for the next 12 weeks to assess toxicity and AUA score. Removal of the stent was planned at six months after PI, or earlier due to excessive toxicity/patient request. Results Median age was 66.5 years. The median prostate volume was 39 cc (range: 10-90). The median baseline AUA score was 7.5 (range: 1-21). Three patients required intermittent self-catheterization (ISC) within 3 days after PI. No patients required ISC beyond day 3 after PI. The median duration of ISC was 1 day (range: 1-2). AUA scores returned to baseline values 6 weeks after PI. The week 6 AUA score was 10 (range: 4-16). Seven patients (35%) underwent early removal because of patient preference. The reasons were: incontinence (n = 3), discomfort (n = 2), hematuria (n = 1), and obstructive symptoms (n = 1). The median time of stent removal in these patients was 13.9 weeks (range: 0.9-21.4). Thirteen patients (65%) had ISC and/or urinary catheterization post stent removal. Median time for ISC use was 10 days (range: 1-90). Conclusions Urethral stenting with Memokath® in patients undergoing PI was feasible, but resulted in relatively high rate of urinary incontinence and discomfort. Given the adverse effects experienced by patients of this study, further studies should focus only on patients with highest risk of urinary obstruction from PI or those with obstruction needing ISC. PMID:27877196

  3. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mashouf, S; Merino, T; Ravi, A

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contoursmore » in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.« less

  4. 12 CFR 550.125 - How do I file the notice under § 550.70(c)?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false How do I file the notice under § 550.70(c)? 550.125 Section 550.125 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Obtaining Fiduciary Powers § 550.125 How do I file the notice under...

  5. 12 CFR 550.125 - How do I file the notice under § 550.70(c)?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 5 2011-01-01 2011-01-01 false How do I file the notice under § 550.70(c)? 550.125 Section 550.125 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY FIDUCIARY POWERS OF SAVINGS ASSOCIATIONS Obtaining Fiduciary Powers § 550.125 How do I file the notice under...

  6. N-iodoacetyltyramine: Preparation and use in sup 125 I labeling by alkylation of sulfhydryl groups

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, C.M.; Mihal, K.A.; Krueger, R.J.

    1989-06-01

    Preparation and use of N-iodoacetyltyramine in generation of {sup 125}I-labeled compounds is described. The kinetics of alkylation of N-acetylcysteine by N-iodoacetyltyramine (k2 = 3.0 M-1 s-1) and N-chloroacetyltyramine (k2 = 0.12 M-1 s-1) indicate that N-iodoacetyltyramine is more useful for labeling sulfhydryl-containing compounds to high specific activity with {sup 125}I. Conditions for preparation of carrier-free {sup 125}I-labeled N-iodoacetyl-3-monoiodotyramine in 50% yield based on starting iodide are described. The high degree of group specificity of N-iodoacetyl-3-monoiodotyramine reaction with sulfhydryl groups is demonstrated by the high reactivity toward sulfhydryl-containing bovine serum albumin and low reactivity toward N-ethylmaleimide-blocked bovine serum albumin and IgG.more » {sup 125}I-labeled N-iodoacetyl-3-monoiodotyramine was also used to prepare an {sup 125}I-labeled ACTH derivative that retains full biological activity, further demonstrating the selectivity toward reactions with sulfhydryl groups.« less

  7. [125I]2-(2-chloro-4-iodo-phenylamino)-5-methyl-pyrroline (LNP 911), a high-affinity radioligand selective for I1 imidazoline receptors.

    PubMed

    Greney, Hugues; Urosevic, Dragan; Schann, Stephan; Dupuy, Laurence; Bruban, Véronique; Ehrhardt, Jean-Daniel; Bousquet, Pascal; Dontenwill, Monique

    2002-07-01

    The I1 subtype of imidazoline receptors (I1R) is a plasma membrane protein that is involved in diverse physiological functions. Available radioligands used so far to characterize the I(1)R were able to bind with similar affinities to alpha2-adrenergic receptors (alpha2-ARs) and to I1R. This feature was a major drawback for an adequate characterization of this receptor subtype. New imidazoline analogs were therefore synthesized and the present study describes one of these compounds, 2-(2-chloro-4-iodo-phenylamino)-5-methyl-pyrroline (LNP 911), which was of high affinity and selectivity for the I1R. LNP 911 was radioiodinated and its binding properties characterized in different membrane preparations. Saturation experiments with [125I]LNP 911 revealed a single high affinity binding site in PC-12 cell membranes (K(D) = 1.4 nM; B(max) = 398 fmol/mg protein) with low nonspecific binding. [125I]LNP 911 specific binding was inhibited by various imidazolines and analogs but was insensitive to guanosine-5'-O-(3-thio)triphosphate. The rank order of potency of some competing ligands [LNP 911, PIC, rilmenidine, 4-chloro-2-(imidazolin-2-ylamino)-isoindoline (BDF 6143), lofexidine, and clonidine] was consistent with the definition of [125I]LNP 911 binding sites as I1R. However, other high-affinity I1R ligands (moxonidine, efaroxan, and benazoline) exhibited low affinities for these binding sites in standard binding assays. In contrast, when [125I]LNP 911 was preincubated at 4 degrees C, competition curves of moxonidine became biphasic. In this case, moxonidine exhibited similar high affinities on [125I]LNP 911 binding sites as on I1R defined with [125I]PIC. Moxonidine proved also able to accelerate the dissociation of [125I]LNP 911 from its binding sites. These results suggest the existence of an allosteric modulation at the level of the I1R, which seems to be corroborated by the dose-dependent enhancement by LNP 911 of the agonist effects on the adenylate cyclase pathway

  8. Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovard R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J).more » Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.« less

  9. In vivo binding of /sup 125/I-LSD to serotonin 5-HT/sub 2/ receptors in mouse brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartig, P.R.; Scheffel, U., Frost, J.J.; Wagner, H.N. Jr.

    The binding of /sup 125/I-LSD (2-(/sup 125/I)-lysergic acid diethylamide) was studied in various mouse brain regions following intravenous injection of the radioligand. The high specific activity of /sup 125/I-LSD enabled the injection of low mass doses (14ng/kg), which are well below the threshold for induction of any known physiological effect of the probe. The highest levels of /sup 125/I-LSD binding were found in the frontal cortex, olfactory tubercles, extra-frontal cortex and striatum while the lowest level was found in the cerebellum. Binding was saturable in the frontal cortex but increased linearly in the cerebellum with increasing doses of /sup 125/I-LSD.more » Serotonergic compounds potently inhibited /sup 125/I-LSD binding in cortical regions, olfactory tubercles, and hypothalamus but had no effect in the cerebellum. Dopaminergic compounds caused partial inhibition of binding in the striatum while adrenergic compounds were inactive. From these studies the authors conclude that /sup 125/I-LSD labels serotonin 5-HT/sub 2/ receptor sites in cortical regions with no indication that other receptor sites are labeled. In the olfactory tubercles and hypothalamus, /sup 125/I-LSD labeling occurs predominantly or entirely at serotonic 5-HT/sub 2/ sites. In the striatum, /sup 125/I-LSD labels approximately equal proportions of serotonergic and dopaminergic sites. These data indicate that /sup 125/I-LSD labels serotonin receptors in vivo and suggests that appropriate derivatives of 2I-LSD may prove useful for tomographic imaging of serotonin 5-HT/sub 2/ receptors in the mammalian cortex.« less

  10. Photoacoustic imaging of prostate brachytherapy seeds with transurethral light delivery

    NASA Astrophysics Data System (ADS)

    Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.

    2014-03-01

    We present a novel approach to photoacoustic imaging of prostate brachytherapy seeds utilizing an existing urinary catheter for transurethral light delivery. Two canine prostates were surgically implanted with brachyther- apy seeds under transrectal ultrasound guidance. One prostate was excised shortly after euthanasia and fixed in gelatin. The second prostate was imaged in the native tissue environment shortly after euthanasia. A urinary catheter was inserted in the urethra of each prostate. A 1-mm core diameter optical fiber coupled to a 1064 nm Nd:YAG laser was inserted into the urinary catheter. Light from the fiber was either directed mostly parallel to the fiber axis (i.e. end-fire fire) or mostly 90° to the fiber axis (i.e. side-fire fiber). An Ultrasonix SonixTouch scanner, transrectal ultrasound probe with curvilinear (BPC8-4) and linear (BPL9-5) arrays, and DAQ unit were utilized for synchronized laser light emission and photoacoustic signal acquisition. The implanted brachytherapy seeds were visualized at radial distances of 6-16 mm from the catheter. Multiple brachytherapy seeds were si- multaneously visualized with each array of the transrectal probe using both delay-and-sum (DAS) and short-lag spatial coherence (SLSC) beamforming. This work is the first to demonstrate the feasibility of photoacoustic imaging of prostate brachytherapy seeds using a transurethral light delivery method.

  11. Improvement of kink characteristic of proton-implanted VCSEL with ITO overcoating

    NASA Astrophysics Data System (ADS)

    Lai, Fang-I.; Chang, Ya-Hsien; Laih, Li-Hong; Kuo, Hao-chung; Wang, S. C.

    2004-06-01

    Proton implanted VCSEL has been demonstrated with good reliability and decent modulation speed up to 1.25 Gb/s. However, kinks in current vs light output (L-I) has been always an issue in the gain-guided proton implant VCSEL. The kink related jitter and noise performance made it difficult to meet 2.5 Gb/s (OC-48) requirement. The kinks in L-I curve can be attributed to non-uniform carrier distribution induced non-uniform gain distribution within emission area. In this paper, the effects of a Ti/ITO transparent over-coating on the proton-implanted AlGaAs/GaAs VCSELs (15um diameter aperture) are investigated. The kinks distribution in L-I characteristics from a 2 inch wafer is greatly improved compared to conventional process. These VCSELs exhibit nearly kink-free L-I output performance with threshold currents ~3 mA, and the slope efficiencies ~ 0.25 W/A. The near-field emission patterns suggest the Ti/ITO over-coating facilitates the current spreading and uniform carrier distribution of the top VCSEL contact thus enhancing the laser performance. Finally, we performed high speed modulation measurement. The eye diagram of proton-implanted VCSELs with Ti/ITO transparent over-coating operating at 2.125 Gb/s with 10mA bias and 9dB extinction ratio shows very clean eye with jitter less than 35 ps.

  12. Is cone beam computed tomography accurate for postoperative evaluation of implants? An in vitro study.

    PubMed

    Vidor, Michele Machado; Liedke, Gabriela Salatino; Fontana, Mathias Pante; da Silveira, Heraldo Luis Dias; Arus, Nadia Assein; Lemos, André; Vizzotto, Mariana Boessio

    2017-11-01

    The aim of this study was to evaluate the accuracy of cone beam computed tomography (CBCT) for evaluation of the bone-implant interface in comparison with periapical radiography. Titanium implants were inserted in 74 bovine rib blocks in intimate contact with bone walls and with a gap of 0.125 mm (simulating failure in the osseointegration process). Periapical radiographs were taken with conventional film, and CBCT scans were acquired with i-CAT (0.2 mm and 0.125 mm voxel) and Kodak (0.2 mm and 0.076 mm voxel) units. Three examiners evaluated the images using a 5-point scale. Diagnostic accuracy was analyzed through sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) with 95% confidence intervals (CIs). Intra- and interexaminer agreements were analyzed through Kendall's concordance test. Intra- and interexaminer agreements showed satisfactory results. The greatest accuracy was observed with conventional radiography (AUC = 0.963; CI 95% = 0.891-0.993). I-CAT 0.125-mm images showed good accuracy (AUC = 0.885; CI 95% = 0.790-0.947), with no significant difference compared with conventional radiography. Kodak images had high specificity and low sensitivity, presenting more false-negative results. Conventional radiography showed the highest accuracy for assessment of the bone-implant interface. However, CBCT (i-CAT; 0.125-mm voxel), if available or if performed for preoperative assessment of another implant site, may provide similar accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. An NTCP Analysis of Urethral Complications from Low Doserate Mono- and Bi-Radionuclide Brachytherapy.

    PubMed

    Nuttens, V E; Nahum, A E; Lucas, S

    2011-01-01

    Urethral NTCP has been determined for three prostates implanted with seeds based on (125)I (145 Gy), (103)Pd (125 Gy), (131)Cs (115 Gy), (103)Pd-(125)I (145 Gy), or (103)Pd-(131)Cs (115 Gy or 130 Gy). First, DU(20), meaning that 20% of the urhral volume receive a dose of at least DU(20), is converted into an I-125 LDR equivalent DU(20) in order to use the urethral NTCP model. Second, the propagation of uncertainties through the steps in the NTCP calculation was assessed in order to identify the parameters responsible for large data uncertainties. Two sets of radiobiological parameters were studied. The NTCP results all fall in the 19%-23% range and are associated with large uncertainties, making the comparison difficult. Depending on the dataset chosen, the ranking of NTCP values among the six seed implants studied changes. Moreover, the large uncertainties on the fitting parameters of the urethral NTCP model result in large uncertainty on the NTCP value. In conclusion, the use of NTCP model for permanent brachytherapy is feasible but it is essential that the uncertainties on the parameters in the model be reduced.

  14. iNOS Activity Modulates Inflammation, Angiogenesis, and Tissue Fibrosis in Polyether-Polyurethane Synthetic Implants

    PubMed Central

    Cassini-Vieira, Puebla; Araújo, Fernanda Assis; da Costa Dias, Filipi Leles; Russo, Remo Castro; Andrade, Silvia Passos; Teixeira, Mauro Martins; Barcelos, Luciola Silva

    2015-01-01

    There is considerable interest in implantation techniques and scaffolds for tissue engineering and, for safety and biocompatibility reasons, inflammation, angiogenesis, and fibrosis need to be determined. The contribution of inducible nitric oxide synthase (iNOS) in the regulation of the foreign body reaction induced by subcutaneous implantation of a synthetic matrix was never investigated. Here, we examined the role of iNOS in angiogenesis, inflammation, and collagen deposition induced by polyether-polyurethane synthetic implants, using mice with targeted disruption of the iNOS gene (iNOS−/−) and wild-type (WT) mice. The hemoglobin content and number of vessels were decreased in the implants of iNOS−/− mice compared to WT mice 14 days after implantation. VEGF levels were also reduced in the implants of iNOS−/− mice. In contrast, the iNOS−/− implants exhibited an increased neutrophil and macrophage infiltration. However, no alterations were observed in levels of CXCL1 and CCL2, chemokines related to neutrophil and macrophage migration, respectively. Furthermore, the implants of iNOS−/− mice showed boosted collagen deposition. These data suggest that iNOS activity controls inflammation, angiogenesis, and fibrogenesis in polyether-polyurethane synthetic implants and that lack of iNOS expression increases foreign body reaction to implants in mice. PMID:26106257

  15. iNOS Activity Modulates Inflammation, Angiogenesis, and Tissue Fibrosis in Polyether-Polyurethane Synthetic Implants.

    PubMed

    Cassini-Vieira, Puebla; Araújo, Fernanda Assis; da Costa Dias, Filipi Leles; Russo, Remo Castro; Andrade, Silvia Passos; Teixeira, Mauro Martins; Barcelos, Luciola Silva

    2015-01-01

    There is considerable interest in implantation techniques and scaffolds for tissue engineering and, for safety and biocompatibility reasons, inflammation, angiogenesis, and fibrosis need to be determined. The contribution of inducible nitric oxide synthase (iNOS) in the regulation of the foreign body reaction induced by subcutaneous implantation of a synthetic matrix was never investigated. Here, we examined the role of iNOS in angiogenesis, inflammation, and collagen deposition induced by polyether-polyurethane synthetic implants, using mice with targeted disruption of the iNOS gene (iNOS(-/-)) and wild-type (WT) mice. The hemoglobin content and number of vessels were decreased in the implants of iNOS(-/-) mice compared to WT mice 14 days after implantation. VEGF levels were also reduced in the implants of iNOS(-/-) mice. In contrast, the iNOS(-/-) implants exhibited an increased neutrophil and macrophage infiltration. However, no alterations were observed in levels of CXCL1 and CCL2, chemokines related to neutrophil and macrophage migration, respectively. Furthermore, the implants of iNOS(-/-) mice showed boosted collagen deposition. These data suggest that iNOS activity controls inflammation, angiogenesis, and fibrogenesis in polyether-polyurethane synthetic implants and that lack of iNOS expression increases foreign body reaction to implants in mice.

  16. SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheung, J; Cunha, J; Sudhyadhom, A

    Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from themore » MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received

  17. p-( sup 125 I)iodoclonidine is a partial agonist at the alpha 2-adrenergic receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerhardt, M.A.; Wade, S.M.; Neubig, R.R.

    1990-08-01

    The binding properties of p-(125I)iodoclonidine (( 125I)PIC) to human platelet membranes and the functional characteristics of PIC are reported. (125I)PIC bound rapidly and reversibly to platelet membranes, with a first-order association rate constant (kon) at room temperature of 8.0 +/- 2.7 x 10(6) M-1 sec-1 and a dissociation rate constant (koff) of 2.0 +/- 0.8 x 10(-3) sec-1. Scatchard plots of specific (125I)PIC binding (0.1-5 nM) were linear, with a Kd of 1.2 +/- 0.1 nM. (125I)PIC bound to the same number of high affinity sites as the alpha 2-adrenergic receptor (alpha 2-AR) full agonist (3H) bromoxidine (UK14,304), which representedmore » approximately 40% of the sites bound by the antagonist (3H)yohimbine. Guanosine 5'-(beta, gamma-imido)triphosphate greatly reduced the amount of (125I)PIC bound (greater than 80%), without changing the Kd of the residual binding. In competition experiments, the alpha 2-AR-selective ligands yohimbine, bromoxidine, oxymetazoline, clonidine, p-aminoclonidine, (-)-epinephrine, and idazoxan all had Ki values in the low nanomolar range, whereas prazosin, propranolol, and serotonin yielded Ki values in the micromolar range. Epinephrine competition for (125I)PIC binding was stereoselective. Competition for (3H)bromoxidine binding by PIC gave a Ki of 1.0 nM (nH = 1.0), whereas competition for (3H)yohimbine could be resolved into high and low affinity components, with Ki values of 3.7 and 84 nM, respectively. PIC had minimal agonist activity in inhibiting adenylate cyclase in platelet membranes, but it potentiated platelet aggregation induced by ADP with an EC50 of 1.5 microM. PIC also inhibited epinephrine-induced aggregation, with an IC50 of 5.1 microM. Thus, PIC behaves as a partial agonist in a human platelet aggregation assay. (125I)PIC binds to the alpha 2B-AR in NG-10815 cell membranes with a Kd of 0.5 +/- 0.1 nM.« less

  18. A technical evaluation of the Nucletron FIRST system: conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations.

    PubMed

    Rivard, Mark J; Evans, Dee-Ann Radford; Kay, Ian

    2005-01-01

    The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dose-rate brachytherapy seed remote afterloader (the seedSelectron), (2) utilizes 3D image reconstruction acquired from electromechanically controlled, nonstepping rotation of the ultrasound probe, (3) integrates the control of a remote afterloader with electromechanical control of the ultrasound probe for integrating the clinical procedure into a single system, and (4) automates the transfer of planning information and seed delivery to improve quality assurance and radiation safety. This automated delivery system is specifically intended to address reproducibility and accuracy of seed positioning during implantation. The FIRST computer system includes two software environments: SPOT PRO and seedSelectron; both are used to facilitate treatment planning and brachytherapy seed implantation from beginning to completion of the entire procedure. In addition to these features, the system is reported to meet certain product specifications for seed delivery positioning accuracy and reproducibility, seed calibration accuracy and reliability, and brachytherapy dosimetry calculations. Consequently, a technical evaluation of the FIRST system was performed to determine adherence to manufacturer specifications and to the American Association of Physicists in Medicine (AAPM) Task Group Reports 43, 53, 56, 59, and 64 and recommendations of the American Brachytherapy Society (ABS). The United States Nuclear Regulatory Commission (NRC) has recently added Licensing Guidance for the seedSelectron system under 10 CFR 35.1000. Adherence to licensing guidance is made by referencing applicable AAPM

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muryn, J; Wilkinson, D

    Purpose: The purpose of this work is to evaluate a method for confirming source strength of I-125 seeds in a bulk assay while maintaining sterility and time efficiency. Methods: The I-125 seeds used in this study (STM 1251, Bard Brachytherapy, Inc.) were available as loose seeds or linked in 3, 4, or 5 seed configurations. A third party 10% assay (NIST traceable) is provided. Source strengths ranging from 0.395 to 0.504 U were available for this study. A stand was built out of aluminum to hold an exposure meter (Inovision (Fluke) 451P) at 25 cm above the I-125 sources tomore » measure the exposure rate. Three different seed configurations were measured: loose, linked, and loaded needles (Bard FastFil Seed Implant Needle). The measurements were made in an operating room, and a sterile sheet was used under the non-sterile aluminum stand. Seeds and needles were placed in a sterile tray. Results: One hundred forty-two loose seeds in 5 batches (0.395, 0.395, 0.409, 0.444, 0.444 U/seed) and 902 seeds in 7 batches containing various strands (0.444, 0.444,.0444, 0.466, 0.466, 0.504, 0.504 U/seed) were measured. The average exposure rate per unit activity was measured to be 0.593 mR per hr per U with a standard deviation of 0.016. The Result for loaded needles was 0.261 mR per hr per U with a standard deviation of 0.014. Once the apparatus is set up, measurements of 180 linked sources as supplied in the Bard package requires only a few minutes. Conclusion: The proposed method can confirm the activity of a batch of loose or stranded I-125 seeds within a range of 5%.« less

  20. Use of 2-(/sup 125/I)iodomelatonin to characterize melatonin binding sites in chicken retina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubocovich, M.L.; Takahashi, J.S.

    2-(/sup 125/I)Iodomelatonin binds with high affinity to a site possessing the pharmacological characteristics of a melatonin receptor in chicken retinal membranes. The specific binding of 2-(/sup 125/I)iodomelatonin is stable, saturable, and reversible. Saturation experiments indicated that 2-(/sup 125/I)iodomelatonin labeled a single class of sites with an affinity constant (Kd) of 434 +/- 56 pM and a total number of binding sites (Bmax) of 74.0 +/- 13.6 fmol/mg of protein. The affinity constant obtained from kinetic analysis was in close agreement with that obtained in saturation experiments. Competition experiments showed a monophasic reduction of 2-(/sup 125/I)iodomelatonin binding with a pharmacological ordermore » of indole amine affinities characteristic of a melatonin receptor: 2-iodomelatonin greater than 6-chloromelatonin greater than or equal to melatonin greater than or equal to 6,7-dichloro-2-methylmelatonin greater than 6-hydroxymelatonin greater than or equal to 6-methoxymelatonin much greater than N-acetyltryptamine greater than N-acetyl-5-hydroxytryptamine greater than 5-methoxytryptamine greater than 5-hydroxytryptamine (inactive). The affinities of these melatonin analogs in competing for 2-(/sup 125/I)iodomelatonin binding sites were correlated closely with their potencies for inhibition of the calcium-dependent release of (3H)dopamine from chicken and rabbit retinas, indicating association of the binding site with a functional response regulated by melatonin. The results indicate that 2-(/sup 125/I)iodomelatonin is a selective, high-affinity radioligand for the identification and characterization of melatonin receptor sites.« less

  1. [125I]Iodo-ASEM, a specific in vivo radioligand for α7-nAChR

    PubMed Central

    Gao, Yongjun; Mease, Ronnie C.; Olson, Thao T.; Kellar, Kenneth J.; Dannals, Robert F.; Pomper, Martin G.; Horti, Andrew G.

    2014-01-01

    [125I]Iodo-ASEM, a new radioligand with high affinity and selectivity for α7-nAChRs (Ki = 0.5 nM; α7/α4β2 = 3,414), has been synthesized in radiochemical yield of 33 ± 6% from the corresponding di-butyltriazene derivative and at high specific radioactivity (1,600 Ci/mmol; 59.2 MBq/μmol). [125I]Iodo-ASEM readily entered the brains of normal CD-1 mice and specifically and selectively labeled cerebral α7-nAChRs. [125I]iodo-ASEM is a new useful tool for studying α7-nAChR. PMID:25687449

  2. SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hueso-Gonzalez, F; Vijande, J; Ballester, F

    Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43),more » ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of

  3. [Radiolabelling and assay of Chinese agkistrodon acutus venom with carrier-free Na 125I].

    PubMed

    Gong, Y; Deng, C; Li, S; Li, L; Guan, J

    1995-03-01

    Chinese agkistroden acutus venom (CAAV) was radiolabelled with carrier-free Na 125I by the method of Iodogen. The specific activity and radiochemical purity for radiolabelled products were 4236.5 x 10(10) Bq/mmol and 98%, respectively. Each CAAV molecule carried 0.52 125I atom. Physical and chemical characterization of radiolabelled CAAV was similar to unradiolabelled CAAV. Binding analysis showed that 125I-CAAV was bound to platelet in a saturable manner. Binding sites per platelet were 13,255 +/- 6292/platelet. The dissociation constant (Kd) was 3.2 +/- 0.69 x 10(-10) mol/L. These results are similar to binding sites of other snake venom on platelet. The investigation showed that radiolabelled CAAV made by our laboratory was useful for radioligand binding assay.

  4. Measurement of /sup 125/I-low density lipoprotein uptake in selected tissues of the squirrel monkey by quantitative autoradiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tompkins, R.G.; Schnitzer, J.J.; Yarmush, M.L.

    1988-09-01

    A recently developed technique of absolute quantitative light microscopic autoradiography of /sup 125/I-labeled proteins in biologic specimens was used to measure /sup 125/I-low density lipoprotein (/sup 125/I-LDL) concentration levels in various tissues of the squirrel monkey after 30 minutes of in vivo LDL circulation. Liver and adrenal cortex exhibited high /sup 125/I-LDL concentrations, presumably because of binding to specific cell surface receptors and/or internalization in vascular beds with high permeability to LDL. High tissue concentrations of LDL were associated with the zona fasciculata and reticularis of the adrenal cortex and the interstitial cells of Leydig in the testis; significantly lowermore » levels of /sup 125/I-LDL were observed in the adrenal medulla, the zona glomerulosa, and germinal centers of the testis. Contrary to previous reports, low /sup 125/I-LDL concentrations were observed throughout the gastrointestinal tract and in lymph nodes. In addition, multiple arterial intramural focal areas of high /sup 125/I-LDL concentrations were identified in arteries supplying the adrenal gland, lymph node, small bowel, and liver.« less

  5. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy.

    PubMed

    Haworth, Annette; Mears, Christopher; Betts, John M; Reynolds, Hayley M; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A

    2016-01-07

    Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The 'biological optimisation' considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.

  6. A radiobiology-based inverse treatment planning method for optimisation of permanent l-125 prostate implants in focal brachytherapy

    NASA Astrophysics Data System (ADS)

    Haworth, Annette; Mears, Christopher; Betts, John M.; Reynolds, Hayley M.; Tack, Guido; Leo, Kevin; Williams, Scott; Ebert, Martin A.

    2016-01-01

    Treatment plans for ten patients, initially treated with a conventional approach to low dose-rate brachytherapy (LDR, 145 Gy to entire prostate), were compared with plans for the same patients created with an inverse-optimisation planning process utilising a biologically-based objective. The ‘biological optimisation’ considered a non-uniform distribution of tumour cell density through the prostate based on known and expected locations of the tumour. Using dose planning-objectives derived from our previous biological-model validation study, the volume of the urethra receiving 125% of the conventional prescription (145 Gy) was reduced from a median value of 64% to less than 8% whilst maintaining high values of TCP. On average, the number of planned seeds was reduced from 85 to less than 75. The robustness of plans to random seed displacements needs to be carefully considered when using contemporary seed placement techniques. We conclude that an inverse planning approach to LDR treatments, based on a biological objective, has the potential to maintain high rates of tumour control whilst minimising dose to healthy tissue. In future, the radiobiological model will be informed using multi-parametric MRI to provide a personalised medicine approach.

  7. Dose Escalation to the Dominant Intraprostatic Lesion Defined by Sextant Biopsy in a Permanent Prostate I-125 Implant: A Prospective Comparative Toxicity Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaudet, Marc; Vigneault, Eric; Aubin, Sylviane

    2010-05-01

    Purpose: Using real-time intraoperative inverse-planned permanent seed prostate implant (RTIOP/PSI), multiple core biopsy maps, and three-dimensional ultrasound guidance, we planned a boost volume (BV) within the prostate to which hyperdosage was delivered selectively. The aim of this study was to investigate the potential negative effects of such a procedure. Methods and Materials: Patients treated with RTIOP/PSI for localized prostate cancer with topographic biopsy results received an intraprostatic boost (boost group [BG]). They were compared with patients treated with a standard plan (reference group [RG]). Plans were generated using a simulated annealing inverse planning algorithm. Prospectively recorded urinary, rectal, and sexualmore » toxicities and dosimetric parameters were compared between groups. Results: The study included 120 patients treated with boost technique who were compared with 70 patients treated with a standard plan. Boost technique did not significantly change the number of seeds (55.1/RG vs. 53.6/BG). The intraoperative prostate V150 was slightly higher in BG (75.2/RG vs. 77.2/BG, p = 0.039). Urethra V100, urethra D90, and rectal D50 were significantly lower in the BG. No significant differences were seen in acute or late urinary, rectal, or sexual toxicities. Conclusions: Because there were no differences between the groups in acute and late toxicities, we believe that BV can be planned and delivered to the dominant intraprostatic lesion without increasing toxicity. It is too soon to say whether a boost technique will ultimately increase local control.« less

  8. Long-Term Results of Brachytherapy With Temporary Iodine-125 Seeds in Children With Low-Grade Gliomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korinthenberg, Rudolf, E-mail: rudolf.korinthenberg@uniklinik-freiburg.d; Neuburger, Daniela; Trippel, Michael

    Purpose: To retrospectively review the results of temporary I-125 brachytherapy in 94 children and adolescents with low-grade glioma. Methods and Materials: Treatment was performed in progressive tumors roughly spherical in shape with a diameter of up to 5 cm, including 79 astrocytomas, 5 oligodendrogliomas, 4 oligoastrocytomas, 1 ependymoma, and 5 other tumors. Location was suprasellar/chiasmal in 44, thalamic/basal ganglia in 18, hemispheric in 15, midbrain/pineal region in 13, and lower brainstem in 3. Initially, 8% of patients were free of symptoms, 47% were symptomatic but not disabled, and 30% were slightly, 6% moderately, and 3% severely disabled. Results: 5- andmore » 10-year survival was 97% and 92%. The response to I-125 brachytherapy over the long term was estimated after a median observation period of 38.4 (range, 6.4-171.0) months. At that time, 4 patients were in complete, 27 in partial, and 18 in objective remission; 15 showed stable and 30 progressive tumors. Treatment results did not correlate with age, sex, histology, tumor size, location, or demarcation of the tumor. Secondary treatment became necessary in 36 patients, including 19 who underwent repeated I-125 brachytherapy. At final follow-up, the number of symptom-free patients had risen to 21%. Thirty-eight percent showed symptoms without functional impairment, 19% were slightly and 11% moderately disabled, and only 4% were severely disabled. Conclusions: Response rates similar to those of conventional radiotherapy or chemotherapy can be anticipated with I-125 brachytherapy in tumors of the appropriate size and shape. We believe it to be a useful contribution to the treatment of low-grade gliomas in children.« less

  9. Specific uptake, dissociation, and degradation of /sup 125/I-labeled insulin in isolated turtle (Chrysemys dorbigni) thyroid glands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marques, M.; da Silva, R.S.; Turyn, D.

    1985-11-01

    Thyroid glands from turtles (Chrysemys dorbigni) pretreated with potassium iodide were incubated with /sup 125/I-insulin in the presence or absence of unlabeled insulin, in order to study its specific uptake. At 24 degrees, the specific uptake reached a plateau at 180 min of incubation. The dose of bovine insulin that inhibited 50% of the /sup 125/I-insulin uptake was 2 micrograms/ml of incubation medium. Most of the radioactive material (71%) extracted from the gland, after 30 min incubation with /sup 125/I-insulin, eluted in the same position as labeled insulin on Sephadex G-50. Only 24% eluted in the salt position. After 240more » min incubation, increased amount of radioactivity appeared in the Na/sup 125/I position. When bovine insulin was added together with the labeled hormone, a substantial reduction of radioactivity was observed in the insulin and Na/sup 125/I elution positions. Dissociation studies were performed at 6 degrees in glands preincubated with /sup 125/I-insulin either at 24 or 6 degrees. The percentage of trichloroacetic acid (TCA)-soluble radioactive material in the dissociation medium increased with incubation time at both temperatures. However, the degradation activity was lower at 6 than at 24 degrees. The addition of bovine insulin to the incubation buffer containing /sup 125/I-insulin reduced the radioactive degradation products in the dissociated medium. Chloroquine or bacitracin inhibited the degradation activity. Incubation of thyroid glands with /sup 125/I-hGH or /sup 125/I-BSA showed values of uptake, dissociation, and degradation similar to those experiments in which an excess of bovine insulin was added together with the labeled hormone. Thus, by multiple criteria, such as specific uptake, dissociation, and degradation, the presence of insulin-binding sites in the turtle thyroid gland may be suggested.« less

  10. Dosimetric variations in permanent breast seed implant due to patient arm position.

    PubMed

    Watt, Elizabeth; Husain, Siraj; Sia, Michael; Brown, Derek; Long, Karen; Meyer, Tyler

    2015-01-01

    Planning and delivery for permanent breast seed implant (PBSI) are performed with the ipsilateral arm raised; however, changes in implant geometry can be expected because of healing and anatomical motion as the patient resumes her daily activities. The purpose of this study is to quantify the effect of ipsilateral arm position on postplan dosimetry. Twelve patients treated at the Tom Baker Cancer Centre were included in this study. Patients underwent two postimplant CT scans on the day of implant (Day 0) and two scans approximately 8 weeks later (Day 60). One scan at each time was taken with the ipsilateral arm raised, recreating the planning scan position, and the other with both arms down in a relaxed position beside the body, recreating a more realistic postimplant arm position. Postplans were completed on all four scans using deformable image registration (MIM Maestro). On the Day 0 scan, the V200 for the evaluation planning target volume was significantly increased in the arm-down position compared with the arm-up position. Lung, rib, and chest wall dose were significantly reduced at both time points. Left anterior descending coronary artery, heart, and skin dose showed no significant differences at either time point. Although some dosimetric indices show significant differences between the arm-up and arm-down positions, the magnitude of these differences is small and the values remain indicative of implant quality. Despite the delivery of the majority of dose with the arm down, it is reasonable to use CT scans taken in the arm-up position for postplanning. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Synthesis and evaluation of [125I]I-TSA as a brain nicotinic acetylcholine receptor alpha7 subtype imaging agent.

    PubMed

    Ogawa, Mikako; Tatsumi, Ryo; Fujio, Masakazu; Katayama, Jiro; Magata, Yasuhiro

    2006-04-01

    Some in vitro investigations have suggested that the nicotinic acetylcholine receptor (nAChR) alpha7 subtype is implicated in Alzheimer's disease, schizophrenia and others. Recently, we developed (R)-3'-(5-bromothiophen-2-yl)spiro[1-azabicyclo[2.2.2]octane-3,5'-[1',3']oxazolidin]-2'-one (Br-TSA), which has a high affinity and selectivity for alpha7 nAChRs. Therefore we synthesized (R)-3'-(5-[125I]iodothiophen-2-yl)spiro[1-azabicyclo[2.2.2]octane-3,5'-[1',3']oxazolidin]-2'-one ([125I]I-TSA) and evaluated its potential for the in vivo detection of alpha7 nAChR in brain. In vitro binding affinity of I-TSA was measured in rat brain homogenates. Radioiodination was accomplished by a Br-I exchange reaction. Biodistribution studies were undertaken in mice by tail vein injection of [(125)I]I-TSA. In vivo receptor blocking studies were carried out by treating mice with methyllycaconitine (MLA; 5 nmol/5 mul, i.c.v.) or nonradioactive I-TSA (50 micromol/kg, i.v.). I-TSA exhibited a high affinity and selectivity for the alpha7 nAChR (K(i) for alpha7 nAChR = 0.54 nM). Initial uptake in the brain was high (4.42 %dose/g at 5 min), and the clearance of radioactivity was relatively slow in the hippocampus (alpha7 nAChR-rich region) and was rather rapid in the cerebellum (alpha7 nAChR poor region). The hippocampus to cerebellum uptake ratio was 0.9 at 5 min postinjection, but it was increased to 1.8 at 60 min postinjection. Although the effect was not statistically significant, administration of I-TSA and MLA decreased the accumulation of radioactivity in hippocampus. Despite its high affinity and selectivity, [125I]I-TSA does not appear to be a suitable tracer for in vivo alpha7 nAChR receptor imaging studies due to its high nonspecific binding. Further structural optimization is needed.

  12. /sup 125/I interstitial implants in the RIF-1 murine flank tumor: an animal model for brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, M.; Gutin, P.H.; Weaver, D.A.

    1982-09-01

    The development of a model for interstitial brachytherapy that uses high-activity, removable /sup 125/I sources in the RIF-1 murine flank tumor is reported. Experimental end points are clonogenic cell and tumor regrowth delay assays. For the clonogenic cell assay, interestitial radiation is delivered at total doses of 500-10,000 rad at dose rates of 0.9-2.7 rad/min to cells in annuli of tissue in the tumor. Dose-survival curves are characterized by an initial shoulder followed by a straight (exponential) portion, with D/sub 0/ similar to that of the curve obtained by external irradiation of the RIF-1 tumor in a self-contained cesium irradiatormore » at similar dose rates. Tumor regrowth curves have been obtained for minimum tumor doses of 500-5000 rad; marked tumor regression has been observed with minimum tumor doses as low as 2000 rad, but results are not as reproducible as the results obtained with the clonogenic cell assay.« less

  13. Synthesis of 4-(3'-[125I]iodoanilino)-6,7-dialkoxyquinazolines:radiolabeled epidermal growth factor receptor tyrosine kinaseinhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, John K.; Negash, Kitaw; Hanrahan, Stephen M.

    1999-10-25

    The preparation of two radioiodinated analogs of theepidermal growth factor receptor tyrosine kinase (EGFrTK) inhibitorPD153035(4-(3'-bromoanilino)-6,7-dimethoxyquinazoline) are reportedherein. The two analogs,4-(3'-[125I]iodoanilino)-6,7-dimethoxyquinazoline and4-(3'-[125I]iodoanilino)-6,7-diethoxyquinazoline, were synthesizedviaiododestannylation of the corresponding4-(3'-trimethylstannylanilino)-6,7-dialkoxyquinazolines to form thedesired I-125 labeled products in good yield and high radiochemicalpurity (>99 percent).

  14. An experimental palladium-103 seed (OptiSeed{sup exp}) in a biocompatible polymer without a gold marker: Characterization of dosimetric parameters including the interseed effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abboud, F.; Scalliet, P.; Vynckier, S.

    Permanent implantation of {sup 125}I (iodine) or {sup 103}Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast implant, similar to that used in the treatment of prostate cancer, has been proposed by [N. Jansen et al., Int. J. Radiat. Oncol. Biol. Phys. 67, 1052-1058 (2007)] with encouraging results. The presence of artifacts from the metallic seeds, however, can disturb follow-up imaging. The development of plastic seeds has reduced thesemore » artifacts. This paper presents a feasibility study of the advantages of palladium-103 seeds, encapsulated with a biocompatible polymer, for future clinical applications, and on the effect of the gold marker on the dosimetric characteristics of such seeds. Experimental palladium seeds, OptiSeed{sup exp}, were manufactured by International Brachytherapy (IBt), Seneffe, Belgium, from a biocompatible polymer, including the marker. Apart from the absence of a gold marker, the studied seed has an identical design to the OptiSeed{sup 103}[Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)]. Polymer encapsulation was preferred by IBt in order to reduce the quantity of radioactive material needed for a given dose rate and to reduce the anisotropy of the radiation field around the seed. In addition, this design is intended to decrease the interseed effects that can occur as a result of the marker and the encapsulation. Dosimetric measurements were performed using LiF thermoluminescent dosimeters (1 mm{sup 3}) in solid water phantoms (WT1). Measured data were compared to Monte Carlo simulated data in solid water using the MCNP code, version 4C. Updated cross sections [Med. Phys. 30, 701-711 (2003)] were used. As the measured and calculated data were in agreement, Monte Carlo calculations were

  15. Prostate Brachytherapy Seed Reconstruction with Gaussian Blurring and Optimal Coverage Cost

    PubMed Central

    Lee, Junghoon; Liu, Xiaofeng; Jain, Ameet K.; Song, Danny Y.; Burdette, E. Clif; Prince, Jerry L.; Fichtinger, Gabor

    2009-01-01

    Intraoperative dosimetry in prostate brachytherapy requires localization of the implanted radioactive seeds. A tomosynthesis-based seed reconstruction method is proposed. A three-dimensional volume is reconstructed from Gaussian-blurred projection images and candidate seed locations are computed from the reconstructed volume. A false positive seed removal process, formulated as an optimal coverage problem, iteratively removes “ghost” seeds that are created by tomosynthesis reconstruction. In an effort to minimize pose errors that are common in conventional C-arms, initial pose parameter estimates are iteratively corrected by using the detected candidate seeds as fiducials, which automatically “focuses” the collected images and improves successive reconstructed volumes. Simulation results imply that the implanted seed locations can be estimated with a detection rate of ≥ 97.9% and ≥ 99.3% from three and four images, respectively, when the C-arm is calibrated and the pose of the C-arm is known. The algorithm was also validated on phantom data sets successfully localizing the implanted seeds from four or five images. In a Phase-1 clinical trial, we were able to localize the implanted seeds from five intraoperative fluoroscopy images with 98.8% (STD=1.6) overall detection rate. PMID:19605321

  16. Effects of Heparin and ε-Aminocaproic Acid in Dogs on Plasmin- 125I Generation in Response to Urokinase Injections and Venous Injury

    PubMed Central

    Takeda, Y.; Parkhill, T. R.; Nakabayashi, M.

    1972-01-01

    The isotopic method described previously for quantification of plasmin- 125I by disc gel electrophoresis was modified by inclusion of euglobulin precipitation to expand its applicability to plasmas containing low radioactivity of plasmin- 125I and plasminogen- 125I. It was found that the euglobulin precipitation method precipitates 72.4±2.1 (sd)% of both plasmin- 125I and plasminogen- 125I. Using this method and plasminogen- 125I as a tracer, studies were first made of the effects of heparin and ε-aminocaproic acid in dogs on plasmin- 125I generation in responese to a single injection of urokinase and to venous injury; second, of the effects of venous occlusion and thrombosis on plasmin- 125I generation; and third, in vitro studies of plasminogen- 125I affinity to fibrin and its activation in blood clots. The venous injury was produced by the damage of venous endothelium by an injection of 90% phenol and the thrombosis by a thrombin injection into an occluded vein. Heparin and ε-aminocaproic acid under the present experimental conditions inhibited about 78 and 100%, respectively of plasmin- 125I generation by the urokinase injection. Similar inhibitory effects of heparin and ε-aminocaproic acid were observed on plasmin- 125I generation in response to venous injury. The venous occlusion caused a small degree of plasmin- 125I generation, but thrombin thrombosis did not seem to stimulate the generation of plasmin- 125I. The in vitro studies showed that plasminogen- 125I does not have a specific affinity to fibrin and is incorporated into blood clots in approximately equal concentrations as those in serum during clotting processes, and that blood clots per se do not stimulate plasmin- 125I generation. These results suggest that injured veins release considerable amounts of vascular plasminogen activators into circulation and that these play an important role in thrombus dissolution in vivo. PMID:4262519

  17. delta 9-(16 alpha-/sup 125/I)iodo-19-nortestosterone: a gamma-emitting photoaffinity label for the progesterone receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, D.J.; Bullock, D.W.; Hoyte, R.M.

    1988-05-01

    We have synthesized 16 alpha-iodo-4,9-estradien-17 beta-ol-3-one (delta 9-16 alpha-iodo-19-nortestosterone (delta 9-INT)) labeled with 125I (delta 9-(16 alpha-125I)INT) to provide a new gamma-emitting photoaffinity ligand for the progesterone receptor that has many advantages over the currently available (3H)R5020. We have characterized the interaction of delta 9-(16 alpha-125I)INT with the rabbit uterine progesterone receptor and have demonstrated the usefulness of this compound for studies of receptor structure. The binding of 2 nM (3H)progesterone to receptor in rabbit uterine cytosol was specifically competed for by 19-nortestosterone, 16 alpha-iodo-19-nortestosterone, and delta 9-INT. Scatchard analysis demonstrated that delta 9-(16 alpha-125I)INT and (3H)progesterone estimated the samemore » number of binding sites in rabbit uterine cytosol, with a Kd for delta 9-(16 alpha-125I)INT of about 2.7 nM. The binding of delta 9-(16 alpha-125I)INT was inhibited by both progesterone and R5020, whereas testosterone, estradiol, and 5 alpha-dihydrotestosterone were ineffective. In cytosol, delta 9-(16 alpha-125I)INT covalently labeled the same mol wt receptor forms as (3H)R5020. Although the efficiency of cross-linking was similar for (3H)R5020 (3%) and delta 9-(16 alpha-125I)INT (4%), the radioactivity was 10-fold greater due to the higher specific activity of delta 9-(16 alpha-125I)INT and the lack of sample quench. The use of delta 9-(16 alpha-125I)INT greatly increases the sensitivity and efficiency of the photoaffinity labeling technique; it will provide a valuable tool for further studies of the progesterone receptor, allowing the detection of receptor in dilute cytosol after gel electrophoresis under denaturing conditions.« less

  18. [125I]-GR231118: a high affinity radioligand to investigate neuropeptide Y Y1 and Y4 receptors

    PubMed Central

    Dumont, Yvan; Quirion, Rémi

    2000-01-01

    GR231118 (also known as 1229U91 and GW1229), a purported Y1 antagonist and Y4 agonist was radiolabelled using the chloramine T method. [125I]-GR231118 binding reached equilibrium within 10 min at room temperature and remained stable for at least 4 h. Saturation binding experiments showed that [125I]-GR231118 binds with very high affinity (Kd of 0.09–0.24 nM) in transfected HEK293 cells with the rat Y1 and Y4 receptor cDNA and in rat brain membrane homogenates. No specific binding sites could be detected in HEK293 cells transfected with the rat Y2 or Y5 receptor cDNA demonstrating the absence of significant affinity of GR231118 for these two receptor classes. Competition binding experiments revealed that specific [125I]-GR231118 binding in rat brain homogenates is most similar to that observed in HEK293 cells transfected with the rat Y1, but not rat Y4, receptor cDNA. Autoradiographic studies demonstrated that [125I]-GR231118 binding sites were fully inhibited by the Y1 antagonist BIBO3304 in most areas of the rat brain. Interestingly, high percentage of [125I]-GR231118/BIBO3304-insensitive binding sites were detected in few areas. These [125I]-GR231118/BIBO3304-insensitive binding sites likely represent labelling to the Y4 receptor subtype. In summary, [125I]-GR231118 is a new radiolabelled probe to investigate the Y1 and Y4 receptors; its major advantage being its high affinity. Using highly selective Y1 antagonists such as BIBO3304 or BIBP3226 it is possible to block the binding of [125I]-GR231118 to the Y1 receptor allowing for the characterization and visualization of the purported Y4 subtype. PMID:10694200

  19. Development of a high specific activity radioligand, /sup 125/I-LSD, and its application to the study of serotonin receptors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadan, M.J.

    /sup 125/I-Labeled receptor ligands can be synthesized with specific activities exceeding 2000 Ci/mmol, making them nearly 70-fold more sensitive in receptor site assays than (mono) tritiated ligands. We have synthesized and characterized /sup 125/I-lysergic acid diethylamide (/sup 125/I-LSD), the first radioiodinated ligand for serotonin receptor studies. The introduction of /sup 125/I at the 2 position of LSD increased both the affinity and selectivity of this compound for serotonin 5-HT/sub 2/ receptors in rat cortex. The high specific activity of /sup 125/I-LSD and its high ratio of specific to nonspecific binding make this ligand especially useful for autoradiographic studies of serotoninmore » receptor distribution. We have found that /sup 125/I-LSD binds with high affinity to a class of serotonin receptors in the CNS of the marine mollusk Aplysia californica.« less

  20. DNA-incorporated 125I induces more than one double-strand break per decay in mammalian cells.

    PubMed

    Elmroth, Kecke; Stenerlöw, Bo

    2005-04-01

    The Auger-electron emitter 125I releases cascades of 20 electrons per decay that deposit a great amount of local energy, and for DNA-incorporated 125I, approximately one DNA double-strand break (DSB) is produced close to the decay site. To investigate the potential of 125I to induce additional DSBs within adjacent chromatin structures in mammalian cells, we applied DNA fragment-size analysis based on pulsed-field gel electrophoresis (PFGE) of hamster V79-379A cells exposed to DNA-incorporated 125IdU. After accumulation of decays at -70 degrees C in the presence of 10% DMSO, there was a non-random distribution of DNA fragments with an excess of fragments <0.5 Mbp and the measured yield was 1.6 DSBs/decay. However, since these experiments were performed under high scavenging conditions (DMSO) that reduce indirect effects, the yield in cells exposed to 125IdU under physiological conditions would most likely be even higher. In contrast, using a conventional low-resolution assay without measurement of smaller DNA fragments, the yield was close to one DSB/decay. We conclude that a large fraction of the DSBs induced by DNA-incorporated 125I are nonrandomly distributed and that significantly more than one DSB/decay is induced in an intact cell. Thus, in addition to DSBs produced close to the decay site, DSBs may also be induced within neighboring chromatin fibers, releasing smaller DNA fragments that are not detected by conventional DSB assays.

  1. Gene expression profiles in promoted-growth rice seedlings that germinated from the seeds implanted by low-energy N+ beam

    PubMed Central

    Ya, Huiyuan; Chen, Qiufang; Wang, Weidong; Chen, Wanguang; Qin, Guangyong; Jiao, Zhen

    2012-01-01

    The stimulation effect that some beneficial agronomic qualities have exhibited in present-generation plants have also been observed due to ion implantation on plants. However, there is relatively little knowledge regarding the molecular mechanism of the stimulation effects of ion-beam implantation. In order to extend our current knowledge about the functional genes related to this stimulation effect, we have reported a comprehensive microarray analysis of the transcriptome features of the promoted-growth rice seedlings germinating from seeds implanted by a low-energy N+ beam. The results showed that 351 up-regulated transcripts and 470 down-regulated transcripts, including signaling proteins, kinases, plant hormones, transposable elements, transcription factors, non-coding protein RNA (including miRNA), secondary metabolites, resistance proteins, peroxidase and chromatin modification, are all involved in the stimulating effects of ion-beam implantation. The divergences of the functional catalog between the vacuum and ion implantation suggest that ion implantation is the principle cause of the ion-beam implantation biological effects, and revealed the complex molecular networks required to adapt to ion-beam implantation stress in plants, including enhanced transposition of transposable elements, promoted ABA biosynthesis and changes in chromatin modification. Our data will extend the current understanding of the molecular mechanisms and gene regulation of stimulation effects. Further research on the candidates reported in this study should provide new insights into the molecular mechanisms of biological effects induced by ion-beam implantation. PMID:22843621

  2. A Systematic Review and Head-to-Head Meta-Analysis of Outcomes following Direct-to-Implant versus Conventional Two-Stage Implant Reconstruction.

    PubMed

    Basta, Marten N; Gerety, Patrick A; Serletti, Joseph M; Kovach, Stephen J; Fischer, John P

    2015-12-01

    Innovative approaches to reconstruction have ushered in an era of breast reconstruction in which direct-to-implant procedures can provide an immediately reconstructed breast. Balancing the benefits against its technical challenges is vital. The authors evaluated the safety and efficacy of using direct-to-implant versus conventional two-stage reconstruction through a systematic meta-analysis. A literature search identified all articles published after 1999 involving prosthetic-based breast reconstruction as a two-stage tissue expander/implant or direct-to-implant technique. The primary outcomes of interest, including implant loss, capsular contracture, reoperation, and infection, were analyzed by means of head-to-head meta-analysis. Thirteen studies involving 5216 breast reconstructions were included. The average patient age was 47.2 ± 1.0 years, the average body mass index was 24.9 ± 0.8 mg/k2, and the average follow-up was 40.8 months. Wound infection, seroma, and capsular contracture risk were similar between groups. However, direct-to-implant reconstruction was associated with a higher risk for skin flap necrosis (OR, 1.43; p = 0.01; I2 = 51 percent) and reoperation (OR, 1.25; p = 0.04; I2 = 43 percent). Ultimately, the risk for implant loss was nearly two-fold higher with direct-to-implant reconstruction compared with tissue expander/implant reconstruction (OR, 1.87; p = 0.04; I2 = 33 percent). Although direct-to-implant and two-stage tissue expander/implant reconstruction are successful approaches, this meta-analysis demonstrates significantly greater risk of flap necrosis and implant failure with direct-to-implant reconstruction. The authors' findings suggest that the critical component of patient selection is judgment of mastectomy flap tissue quality. These findings can enhance the risk counseling process and highlight the need for additional investigations to optimize outcomes.

  3. Practical considerations for maximizing heat production in a novel thermobrachytherapy seed prototype

    PubMed Central

    Gautam, Bhoj; Warrell, Gregory; Shvydka, Diana; Subramanian, Manny; Ishmael Parsai, E.

    2014-01-01

    Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulating thermal properties. Methods: The new seed's geometry is based on the standard BEST Model 2301 125I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni–Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50 °C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni–Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni–Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and CT images

  4. Practical considerations for maximizing heat production in a novel thermobrachytherapy seed prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gautam, Bhoj; Warrell, Gregory; Shvydka, Diana

    2014-02-15

    Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulatingmore » thermal properties. Methods: The new seed's geometry is based on the standard BEST Model 2301{sup 125}I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni–Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50 °C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni–Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni–Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and

  5. Practical considerations for maximizing heat production in a novel thermobrachytherapy seed prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gautam, Bhoj; Warrell, Gregory; Shvydka, Diana

    Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulatingmore » thermal properties. Methods: The new seed's geometry is based on the standard BEST Model 2301{sup 125}I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni–Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50 °C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni–Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni–Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and

  6. SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elzibak, A; Fatemi-Ardekani, A; Soliman, A

    Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/more » TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best

  7. Enhanced EJ Cell Killing of (125)I Radiation by Combining with Cytosine Deaminase Gene Therapy Regulated by Synthetic Radio-Responsive Promoter.

    PubMed

    Li, Ling; Zhang, Chun-li; Kang, Lei; Wang, Rong-Fu; Yan, Ping; Zhao, Qian; Yin, Lei; Guo, Feng-qin

    2015-10-01

    To investigate the enhancing effect of radionuclide therapy by the therapeutic gene placed under the control of radio-responsive promoter. The recombinant lentivirus E8-codA-GFP, including a synthetic radiation-sensitive promoter E8, cytosine deaminase (CD) gene, and green fluorescent protein gene, was constructed. The gene expression activated by (125)I radiation was assessed by observation of green fluorescence. The ability of converting 5-fluorocytosine (5-FC) to 5-fluorourial (5-FU) by CD enzyme was assessed by high-performance liquid chromatography. The viability of the infected cells exposed to (125)I in the presence of 5-FC was determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and the infected cells exposed to (125)I alone served as negative control and 5-FU as positive control. The recombinant lentiviral vector was constructed successfully. On exposure of infected cells to (125)I, green fluorescence can be observed and 5-FU can be detected. MTT assay showed that the survival rate for infected cells treated with (125)I was lower compared with the (125)I control group, but higher than the positive control group. The synthetic promoter E8 can induce the expression of downstream CD gene under (125)I radiation, and the tumor killing effect of (125)I can be enhanced by combining CD gene therapy with radiosensitive promoter.

  8. Effects of methoxyflurane anesthesia on the pharmacokinetics of 125I-IAZA in Sprague-Dawley rats.

    PubMed

    Stypinski, D; Wiebe, L I; Tam, Y K; Mercer, J R; McEwan, A J

    1999-11-01

    Effects of methoxyflurane anesthesia on the pharmacokinetics of intravenous 125I-IAZA in rats are reported. No significant differences in t(1/2alpha), t(1/2beta), V(SS), and ClTB for total radioactivity (125I-IAZA and metabolites) were observed between the anesthetized (Group 1, n = 4) and nonanesthetized (Group 2, n = 3) animals. For 125I-IAZA, ClTB increased from 646 +/- 52 mL/h/kg to 2250 +/- 351 mL/h/kg and t(1/2beta) decreased from 97.7 +/- 17.5 min to 35.6 +/- 5.4 min, for Groups 1 and 2, respectively. There were no differences in V(SS) or t(1/2alpha) between the two groups. These findings support literature reports of anesthetic effects on xenobiotic pharmacokinetics, and indicate a need for caution in the evaluation of preclinical imaging studies in which animals are immobilized with anesthetics.

  9. Comparison of cyclosporine determinations in whole blood by three different methods. HPLC, /sup 125/I RIA and /sup 3/H RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, W.Y.; Lipsey, A.I.; Cheng, M.H.

    1987-04-01

    The authors have analyzed and compared the cyclosporine concentrations in whole blood specimens from pediatric renal transplant patients using three different methods: high-performance liquid chromatography (HPLC) (5u C18 reverse-phase column), /sup 3/H radioimmunoassay (RIA), and /sup 125/I RIA (substituted /sup 3/H-tracer in Sandoz Kit with /sup 125/I tracer. Results obtained by the /sup 125/I RIA correlated well with results obtained by the /sup 3/H RIA. Both RIA methods had similar correlation with the HPLC method. The /sup 125/I RIA method showed higher sensitivity and greater precision than the /sup 3/H RIA method. The authors conclude that the /sup 125/I RIAmore » method can be used for cyclosporine determination in whole blood specimens. The use of the /sup 125/I RIA provides a simple and rapid method with higher counting efficiency and less background quenching than the /sup 3/H RIA method, which requires cumbersome liquid scintillation counting procedures.« less

  10. Dosimetric parameters of three new solid core I‐125 brachytherapy sources

    PubMed Central

    Solberg, Timothy D.; DeMarco, John J.; Hugo, Geoffrey; Wallace, Robert E.

    2002-01-01

    Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of I125 has been adsorbed, encased within a titanium housing. The PharmaSeed BT‐125 source manufactured by Syncor is available in silver or palladium core configurations while the ADVANTAGE source from IsoAid has silver only. Dosimetric properties, including the dose rate constant, radial dose function, and anisotropy characteristics were determined according to the TG‐43 protocol. Additionally, the geometry function was calculated exactly using Monte Carlo and compared with both the point and line source approximations. The 1999 NIST standard was followed in determining air kerma strength. Dose rate constants were calculated to be 0.955±0.005,0.967±0.005, and 0.962±0.005 cGyh−1U−1 for the PharmaSeed BT‐125‐1, BT‐125‐2, and ADVANTAGE sources, respectively. TLD measurements were in excellent agreement with Monte Carlo calculations. Radial dose function, g(r), calculated to a distance of 10 cm, and anisotropy function F(r, θ), calculated for radii from 0.5 to 7.0 cm, were similar among all source configurations. Anisotropy constants, ϕ¯an, were calculated to be 0.941, 0.944, and 0.960 for the three sources, respectively. All dosimetric parameters were found to be in close agreement with previously published data for similar source configurations. The MCNP Monte Carlo code appears to be ideally suited to low energy dosimetry applications. PACS number(s): 87.53.–j PMID:11958652

  11. Multilayer cell-seeded polymer nanofiber constructs for soft-tissue reconstruction.

    PubMed

    Barker, Daniel A; Bowers, Daniel T; Hughley, Brian; Chance, Elizabeth W; Klembczyk, Kevin J; Brayman, Kenneth L; Park, Stephen S; Botchwey, Edward A

    2013-09-01

    Cell seeding throughout the thickness of a nanofiber construct allows for patient-specific implant alternatives with long-lasting effects, earlier integration, and reduced inflammation when compared with traditional implants. Cell seeding may improve implant integration with host tissue; however, the effect of cell seeding on thick nanofiber constructs has not been studied. To use a novel cell-preseeded nanofiber tissue engineering technique to create a 3-dimensional biocompatible implant alternative to decellularized extracellular matrix. Animal study with mammalian cell culture to study tissue engineered scaffolds. Academic research laboratory. Thirty-six Sprague-Dawley rats. The rats each received 4 implant types. The grafts included rat primary (enhanced green fluorescent protein-positive [eGFP+]) fibroblast-seeded polycaprolactone (PCL)/collagen nanofiber scaffold, PCL/collagen cell-free nanofiber scaffold, acellular human cadaveric dermis (AlloDerm), and acellular porcine dermis (ENDURAGen). Rats were monitored postoperatively and received enrofloxacin in the drinking water for 4 days prophylactically and buprenorphine (0.2-0.5 mg/kg administered subcutaneously twice a day postoperatively for pain for 48 hours). The viability of NIH/3T3 fibroblasts cultured on PCL electrospun nanofibers was evaluated using fluorescence microscopy. Soft-tissue remodeling was examined histologically and with novel ex vivo volume determinations of implants using micro-computed tomography of cell-seeded implants relative to nanofibers without cells and commonly used dermal grafts of porcine and human origin (ENDURAGen and AlloDerm, respectively). The fate and distribution of eGFP+ seeded donor fibroblasts were assessed using immunohistochemistry. Fibroblasts migrated across nanofiber layers within 12 hours and remained viable on a single layer for up to 14 days. Scanning electron microscopy confirmed a nanoscale structure with a mean (SD) diameter of 158 (72) nm. Low extrusion

  12. Identification of the glucose transporter in mammalian cell membranes using an /sup 125/(I)-forskolin photoaffinity label

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruoho, A.; Wadzinski, B.; Shanahan, M.

    1987-05-01

    The glucose transporter has been identified in a variety of mammlian cell membranes using a carrier-free photoactivatable radioiodinated derivative of forskolin, 3-iodo-4-azidophenethylamido-7-0-succinyldeacetyl-forskolin, (I-125)IAPS-Fsk, at 1-10 nM. The membranes which have been photolabeled with (I-125)IAPS-Fsk are: rat cardiac sarcolemmal membranes, rat cortex and cerebellum synaptic membranes, human placental membranes, and wild type S49 lymphoma cell membranes. The glucose transporter in rat cardiac sarcolemmal membranes and rat cortex and cerebellum synaptic membranes was determined to be 45 kDa by SDS-PAGE. Photolysis of human placental membranes and S49 lymphoma membranes with (I-125)IAPS-Fsk followed by SDS-PAGE indicated specific derivatization of a broad band (45-55more » kDa) in placental membranes and a narrower band (45 kDa) in the S49 lymphoma membranes. Digestion of the (I-125)IPAS-Fsk labelled placental and S49 lymphoma membranes with endo-B-galactosidase showed a reduction in the apparent molecular weight of the radiolabelled band to 40 kDa. Trypsinization of labelled placental and lymphoma membranes produced an 18 kDa radiolabelled proteolytic fragment. (I-125)IAPS-Fsk is a highly effective probe for identifying low levels of glucose transporters in mammalian tissues.« less

  13. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash

    2014-02-15

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescriptionmore » doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged

  14. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescriptionmore » doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged

  15. Monte Carlo Determination of Dosimetric Parameters of a New (125)I Brachytherapy Source According to AAPM TG-43 (U1) Protocol.

    PubMed

    Baghani, Hamid Reza; Lohrabian, Vahid; Aghamiri, Mahmoud Reza; Robatjazi, Mostafa

    2016-03-01

    (125)I is one of the important sources frequently used in brachytherapy. Up to now, several different commercial models of this source type have been introduced to the clinical radiation oncology applications. Recently, a new source model, IrSeed-125, has been added to this list. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43 (U1) protocol using Monte Carlo simulation. The dosimetric characteristics of Ir-125 including dose rate constant, radial dose function, 2D anisotropy function and 1D anisotropy function were determined inside liquid water using MCNPX code and compared to those of other commercially available iodine sources. The dose rate constant of this new source was found to be 0.983+0.015 cGyh-1U-1 that was in good agreement with the TLD measured data (0.965 cGyh-1U-1). The 1D anisotropy function at 3, 5, and 7 cm radial distances were obtained as 0.954, 0.953 and 0.959, respectively. The results of this study showed that the dosimetric characteristics of this new brachytherapy source are comparable with those of other commercially available sources. Furthermore, the simulated parameters were in accordance with the previously measured ones. Therefore, the Monte Carlo calculated dosimetric parameters could be employed to obtain the dose distribution around this new brachytherapy source based on TG-43 (U1) protocol.

  16. Monte Carlo study of a new I‐125 brachytherapy prototype seed with a ceramic radionuclide carrier and radiographic marker

    PubMed Central

    Paixão, Lucas; Santos, Ana Maria M.; dos Santos, Adriano Márcio; Grynberg, Suely Epsztein

    2012-01-01

    In prostate cancer treatment, there is an increasing interest in the permanent radioactive seeds implant technique. Currently, in Brazil, the seeds are imported with high prices, which prohibit their use in public hospitals. A ceramic matrix that can be used as a radioisotope carrier and radiographic marker was developed at our institution. The ceramic matrix is distinguished by the characteristic of maintaining the radioactive material uniformly distributed in its surface. In this work, Monte Carlo simulations were performed in order to assess the dose distributions generated by this prototype seed model, with the ceramic matrix encapsulated in titanium, in the same way as the commercial 6711 seed. The obtained data was assessed, as described in the TG‐43U1 report by the American Association of Physicists in Medicine, for two seed models: (1) the most used model 6711 source — for validation and comparison, and (2) for the prototype model with the ceramic matrix. The dosimetric parameters dose rate constant, Λ, radial dose function, gL(r), and anisotropy function, F(r,θ), were derived from simulations by the Monte Carlo method using the MCNP5 code. A Λ 0.992 (±2.33%) cGyh−1U−1 was found for the prototype model. In comparison with the 6711 model, a lower dose fall‐off on transverse axis was found, as well as a lower dose anisotropy for the radius r= 0.25 cm. In general, for all distances, the prototype seed model presents a slightly larger anisotropy between 0° ≤ Θ < 50° and anisotropy similar to the 6711 model for Θ ≥ 50°. The dosimetric characteristics of the prototype model presented in this study suggest that its use is feasible. Because of the model's characteristics, seeds of lower specific activity iodine might be necessary which, on the other hand, would help to reduce costs. However, it has to be emphasized that the proposed source is a prototype, and the required (AAPM prerequisites) experimental study and tolerance

  17. Complementary genetic and genomic approaches help characterize the linkage group I seed protein QTL in soybean

    PubMed Central

    2010-01-01

    Background The nutritional and economic value of many crops is effectively a function of seed protein and oil content. Insight into the genetic and molecular control mechanisms involved in the deposition of these constituents in the developing seed is needed to guide crop improvement. A quantitative trait locus (QTL) on Linkage Group I (LG I) of soybean (Glycine max (L.) Merrill) has a striking effect on seed protein content. Results A soybean near-isogenic line (NIL) pair contrasting in seed protein and differing in an introgressed genomic segment containing the LG I protein QTL was used as a resource to demarcate the QTL region and to study variation in transcript abundance in developing seed. The LG I QTL region was delineated to less than 8.4 Mbp of genomic sequence on chromosome 20. Using Affymetrix® Soy GeneChip and high-throughput Illumina® whole transcriptome sequencing platforms, 13 genes displaying significant seed transcript accumulation differences between NILs were identified that mapped to the 8.4 Mbp LG I protein QTL region. Conclusions This study identifies gene candidates at the LG I protein QTL for potential involvement in the regulation of protein content in the soybean seed. The results demonstrate the power of complementary approaches to characterize contrasting NILs and provide genome-wide transcriptome insight towards understanding seed biology and the soybean genome. PMID:20199683

  18. The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia

    NASA Astrophysics Data System (ADS)

    Wurdiyanto, G.; Candra, H.

    2016-03-01

    The standardization of radioactive sources (125I, 131I, 99mTc and 18F) to calibrate the nuclear medicine equipment had been carried out in PTKMR-BATAN. This is necessary because the radioactive sources used in the field of nuclear medicine has a very short half-life in other that to obtain a quality measurement results require special treatment. Besides that, the use of nuclear medicine techniques in Indonesia develop rapidly. All the radioactive sources were prepared by gravimetric methods. Standardization of 125I has been carried out by photon- photon coincidence methods, while the others have been carried out by gamma spectrometry methods. The standar sources are used to calibrate a Capintec CRC-7BT radionuclide calibrator. The results shows that calibration factor for Capintec CRC-7BT dose calibrator is 1,03; 1,02; 1,06; and 1,04 for 125I, 131I, 99mTc and 18F respectively, by about 5 to 6% of the expanded uncertainties.

  19. Clinical implementation of stereotaxic brain implant optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenow, U.F.; Wojcicka, J.B.

    1991-03-01

    This optimization method for stereotaxic brain implants is based on seed/strand configurations of the basic type developed for the National Cancer Institute (NCI) atlas of regular brain implants. Irregular target volume shapes are determined from delineation in a stack of contrast enhanced computed tomography scans. The neurosurgeon may then select up to ten directions, or entry points, of surgical approach of which the program finds the optimal one under the criterion of smallest target volume diameter. Target volume cross sections are then reconstructed in 5-mm-spaced planes perpendicular to the implantation direction defined by the entry point and the target volumemore » center. This information is used to define a closed line in an implant cross section along which peripheral seed strands are positioned and which has now an irregular shape. Optimization points are defined opposite peripheral seeds on the target volume surface to which the treatment dose rate is prescribed. Three different optimization algorithms are available: linear least-squares programming, quadratic programming with constraints, and a simplex method. The optimization routine is implemented into a commercial treatment planning system. It generates coordinate and source strength information of the optimized seed configurations for further dose rate distribution calculation with the treatment planning system, and also the coordinate settings for the stereotaxic Brown-Roberts-Wells (BRW) implantation device.« less

  20. Distribution of sup 125 I-neurotensin binding sites in human forebrain: Comparison with the localization of acetylcholinesterase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szigethy, E.; Quirion, R.; Beaudet, A.

    1990-07-22

    The distribution of 125I-neurotensin binding sites was compared with that of acetylcholinesterase reactivity in the human basal forebrain by using combined light microscopic radioautography/histochemistry. High 125I-neurotensin binding densities were observed in the bed nucleus of the stria terminalis, islands of Calleja, claustrum, olfactory tubercle, and central nucleus of the amygdala; lower levels were seen in the caudate, putamen, medial septum, diagonal band nucleus, and nucleus basalis of Meynert. Adjacent sections processed for cholinesterase histochemistry demonstrated a regional overlap between the distribution of labeled neurotensin binding sites and that of intense acetylcholinesterase staining in all of the above regions, except inmore » the bed nucleus of the stria terminalis, claustrum, and central amygdaloid nucleus, where dense 125I-neurotensin labeling was detected over areas containing only weak to moderate cholinesterase staining. At higher magnification, 125I-neurotensin-labeled binding sites in the islands of Calleja, supraoptic nucleus of the hypothalamus, medial septum, diagonal band nucleus, and nucleus basalis of Meynert were selectively associated with neuronal perikarya found to be cholinesterase-positive in adjacent sections. Moderate 125I-neurotensin binding was also apparent over the cholinesterase-reactive neuropil of these latter three regions. These data suggest that neurotensin (NT) may directly influence the activity of magnocellular cholinergic neurons in the human basal forebrain, and may be involved in the physiopathology of dementing disorders such as Alzheimer's disease, in which these neurons have been shown to be affected.« less

  1. 32 CFR 37.125 - May I award or administer TIAs if I am authorized to award or administer other assistance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false May I award or administer TIAs if I am... INVESTMENT AGREEMENTS General § 37.125 May I award or administer TIAs if I am authorized to award or administer other assistance instruments? (a) You must have specific authorization to award or administer TIAs...

  2. High affinity binding of 125I-neurotensin to dispersed cells from chicken liver and brain.

    PubMed

    Mitra, S P; Carraway, R E

    1997-01-01

    Dispersed cells from chicken brain and liver were found to possess cell surface binding sites for 125I-neurotensin (125I-NT). Scatchard analyses indicated the presence of high affinity (K4, 25-80 pM) and low affinity (Kd, 250-450 pM) components in adult tissues. Binding capacity was reduced 25-40% by incubation with pertussis toxin. Ontogenetic studies indicated that NT receptor capacity increased approximately 20-fold from the embryonic stage to adult. Cross-linking of 125I-NT to intact cells labeled one major band (52 kDa, > or = 90%) and two minor bands (40 and 90 kDa, < or = 10%) which could represent distinct NT-receptors or one receptor partly degraded or cross-linked to G-protein(s). The binding of 125I-NT to dispersed cells was enhanced by reduction with dithoithreitol and suppressed by alkylation with N-ethyl-maleimide (NEM), maleimidocaproic acid (MCA) and p-chloromercuribenzenesulfonate (PCMBS). Since MCA and PCMBS do not permeate cells, this suggests that the sulfhydryl group(s) critical to binding are located within the NT receptor itself. Preincubation of cells with NT prior to treatment with NEM diminished its inhibitory effect, suggesting that the critical SH-group(s) were within the NT binding pocket or were protected by an allosteric effect. These results suggest that one or more of the nine cysteine residues in the NT receptor is involved in the NT binding reaction.

  3. Characterization of the [125I]-neurokinin A binding site in the circular muscle of human colon

    PubMed Central

    Warner, Fiona J; Comis, Alfio; Miller, Robert C; Burcher, Elizabeth

    1999-01-01

    Neurokinin A (NKA) is a potent contractile agonist of human colon circular muscle. These responses are mediated predominantly through tachykinin NK2 receptors. In the present study, the NK2 receptor radioligand [125I]-NKA has been used to characterize binding sites in this tissue, using tachykinin agonists and antagonists. 125INKA labelled a single, high affinity binding site. Specific binding (95% of total binding) of [125I]-NKA was saturable (KD 0.47±0.05 nM), of high capacity (Bmax 2.1±0.1 fmol mg−1 wet weight tissue) and reversible (kinetically derived KD 0.36±0.07 nM). The rank order of agonists competing for the [125I]-NKA binding site was neuropeptide γ (NPγ)≥NKA≥[Lys5,MeLeu9,Nle10]NKA (4–10) (NK2 agonist)>>substance P (SP)>neurokinin B (NKB)≥[Pro9]SP (NK1 agonist)>>senktide (NK3 agonist), indicating binding to an NK2 site. The nonpeptide selective NK2 antagonist SR48968 showed higher affinity for the [125I]-NKA site than selective peptide NK2 antagonists. The rank order of potency for NK2 antagonists was SR48968≥MEN11420>GR94800≥MEN10627>MEN10376≥R396. The NK1 antagonist SR140333 was a weak competitor. The competition curve for SP could be resolved into two sites. When experiments were repeated in the presence of SR140333 (0.1 μM), the curve for SP became monophasic and showed a significant shift to the right, whereas curves to NKA and NKB were unaffected. In conclusion, binding of the radioligand [125I]-NKA to membranes from circular muscle is predominantly to the NK2 receptor. There may be a small component of binding to the NK1 receptor. The NK2 receptor mediates circular muscle contraction, whereas the role of the NK1 receptor in circular muscle is unclear. PMID:10455255

  4. Strength estimation of a moving 125Iodine source during implantation in brachytherapy: application to linked sources.

    PubMed

    Tanaka, Kenichi; Endo, Satoru; Tateoka, Kunihiko; Asanuma, Osamu; Hori, Masakazu; Takagi, Masaru; Bengua, Gerard; Kamo, Ken-Ichi; Sato, Kaori; Takeda, Hiromitsu; Hareyama, Masato; Sakata, Koh-Ichi; Takada, Jun

    2014-11-01

    This study sought to demonstrate the feasibility of estimating the source strength during implantation in brachytherapy. The requirement for measuring the strengths of the linked sources was investigated. The utilized sources were (125)I with air kerma strengths of 8.38-8.63 U (μGy m(2) h(-1)). Measurements were performed with a plastic scintillator (80 mm × 50 mm × 20 mm in thickness). For a source-to-source distance of 10.5 mm and at source speeds of up to 200 mm s(-1), a counting time of 10 ms and a detector-to-needle distance of 5 mm were found to be the appropriate measurement conditions. The combined standard uncertainty (CSU) with the coverage factor of 1 (k = 1) was ∼15% when using a grid to decrease the interference by the neighboring sources. Without the grid, the CSU (k = 1) was ∼5%, and an 8% overestimation due to the neighboring sources was found to potentially cause additional uncertainty. In order to improve the accuracy in estimating source strength, it is recommended that the measurment conditions should be optimized by considering the tradeoff between the overestimation due to the neighboring sources and the intensity of the measured value, which influences the random error. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  5. Ultrasonographic markers and preoperative CA-125 to distinguish between borderline ovarian tumors and stage I ovarian cancer.

    PubMed

    Zacharakis, Dimitrios; Thomakos, Nikolaos; Biliatis, Ioannis; Rodolakis, Alexandros; Simou, Maria; Daskalakis, Georgios; Bamias, Aris; Antsaklis, Aris

    2013-03-01

    Preoperative evaluation of ovarian masses has become increasingly important for optimal planning of treatment. The aim of this study was to assess the role of preoperative serum cancer antigen 125 (CA-125) levels in correlation with ultrasonographic features in order to distinguish between borderline ovarian tumors (BOTs) and stage I epithelial ovarian carcinoma (EOC). Retrospective study. Tertiary University Hospital. We reviewed all women with BOTs and stage I EOC from January 2000 to December 2010. Data from 165 women (66 BOTs and 99 stage I EOC) were analyzed. Multivariable logistic regression with stepwise selection of variables was used to determine which clinical variables, ultrasound features and CA-125 level were independently associated with invasiveness. Utility of ultrasonographic markers and CA-125 in the preoperative differential diagnosis between BOTs and stage I EOC. Women with CA-125 > 100 IU mL(-1) had almost three times greater likelihood of belonging in the EOC group [odds ratio (OR) 3.02; confidence interval (CI) 95%: 1.13-8.12]. Furthermore, the presence of large solid component (≥20% of the tumor comprised of solid components) was associated with 4.25 times greater odds of it to representing ovarian cancer rather than a BOT (OR 4.25; 95% CI: 2.05-8.82). In contrast, the presence of papillary projections was associated with a 73% lower likelihood of EOC (OR 0.27; 95% CI: 0.13-0.58). Preoperative CA-125 > 100 IU mL(-1) combined with the presence of a large solid component and the absence of papillary projections seems to improve the discriminative ability in favor of stage I EOC. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica © 2012 Nordic Federation of Societies of Obstetrics and Gynecology.

  6. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test.

    PubMed

    Ramos Verri, Fellippo; Santiago Junior, Joel Ferreira; de Faria Almeida, Daniel Augusto; de Oliveira, Guilherme Bérgamo Brandão; de Souza Batista, Victor Eduardo; Marques Honório, Heitor; Noritomi, Pedro Yoshito; Pellizzer, Eduardo Piza

    2015-01-02

    The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p<0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p>0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p<0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p<0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Increased (/sup 125/I)trypsin-binding in serum from cystic fibrosis patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, K.L.; Frates, R.C. Jr.; Sheikholislam, B.M.

    1982-01-01

    The capacities of normal and cystic fibrosis (CF) sera to bind to exogenous human (/sup 125/I)trypsin were compared. Sera from eight older CF patients bound significantly more exogenous human (/sup 125/I)trypsin than did sera from eight normal subjects (p less than 0.001). Disregarding the increased trypsin-binding (TB) of CF sera, serum immunoreactive trypsinogen (SIRT) levels were not detectable in these eight older CF patients. However, when SIRT levels were corrected for TB, four CF patients had normal SIRT concentrations and four had low but detectable SIRT levels. As compared to five normal newborns' sera, serum from a newborn with CFmore » had normal TB and the SIRT levels were very high. In conclusion, increased TB in CF serum lowers results of SIRT assays. Therefore, unless SIRT levels are corrected for TB, results obtained from currently available SIRT kits may be invalid.« less

  8. The Value of Serum CA125 in the Diagnosis of Borderline Tumors of the Ovary: A Subanalysis of the Prospective Multicenter ROBOT Study.

    PubMed

    Fotopoulou, Christina; Sehouli, Jalid; Ewald-Riegler, Nina; de Gregorio, Nikolaus; Reuss, Alexander; Richter, Rolf; Mahner, Sven; Kommoss, Friedrich; Schmalfeldt, Barbara; Fehm, Tanja; Hanker, Lars; Wimberger, Pauline; Canzler, Ulrich; Pfisterer, Jacobus; Kommoss, Stefan; Hauptmann, Steffen; du Bois, Andreas

    2015-09-01

    The value of the serum tumor marker CA125 in borderline tumors of the ovary (BOTs) is not well defined, with unclear benefit in both diagnosis and follow-up. The aim of the present project was to identify the predictive value of CA125 for stage and relapse. CA125 data were extracted from the ROBOT multicenter study of patients with BOT treated between 1998 and 2008 in 24 German centers. While patients' data were retrieved retrospectively from hospital records and clinical tumor registries, follow-up and independent central pathology review were performed prospectively. We identified 127 patients from the ROBOT database fulfilling the eligibility criterion of available CA125 at initial diagnosis. Eighty-three (65.3%) patients had increased CA125 levels (>35 U/L). Of the patients, 85.0% presented with serous and 13.4% with mucinous BOT histology, whereas 29.9% had stage I disease. Fifteen (11.8%) patients experienced a relapse. Multivariate analysis identified raised CA125, young age, and serous histology as independent predictors of peritoneal implants of any type at initial presentation. Raised CA125 at initial diagnosis was, however, not an independent predictor of future relapse. Elevated CA125 seems to be associated with the presence of peritoneal implants of any type at initial diagnosis of serous BOT, but failed to have any independent predictive value on future relapse. Prospective multicenter studies are warranted to evaluate CA125 measurements in the follow-up management of BOT.

  9. Synthesis and evaluation of C-11, F-18 and I-125 small molecule radioligands for detecting oxytocin receptors

    PubMed Central

    Smith, Aaron L.; Freeman, Sara M.; Stehouwer, Jeffery S.; Inoue, Kiyoshi; Voll, Ronald J.; Young, Larry J.; Goodman, Mark M.

    2013-01-01

    Compounds 1–4 were synthesized and investigated for selectivity and potency for the oxytocin receptor (OTR) to determine their viability as radioactive ligands. Binding assays determined 1–4 to have high binding affinity for both the human and rodent OTR and also have high selectivity for the human OTR over human vasopressin V1a receptors (V1aR). Inadequate selectivity for OTR over V1aR was found for rodent receptors in all four compounds. The radioactive (C-11, F-18, and I-125) derivatives of 1–4 were synthesized and investigated for use as autoradiography and positron emission tomography (PET) ligands. Receptor autoradiography performed with [125I]1 and [125I]2 on rodent brain slices provided the first small molecule radioligand images of the OTR and V1aR. Biodistribution studies determined [125I]1 and [125I]2 were adequate for in vivo peripheral investigations, but not for central investigations due to low uptake within the brain. A biodistribution study with [18F]3 suggested brain uptake occurred slowly over time. PET imaging studies with [18F]3 and [11C]4 using a rat model provided insufficient uptake in the brain over a 90 and 45 min scan times respectively to merit further investigations in non-human primates. PMID:22425346

  10. Report on the Clinical Outcomes of Permanent Breast Seed Implant for Early-Stage Breast Cancers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pignol, Jean-Philippe, E-mail: j.p.pignol@erasmusmc.nl; Radiation Oncology Department, Erasmus Medical Center Cancer Institute, Rotterdam; Caudrelier, Jean-Michel

    Purpose: Permanent breast seed implant is an accelerated partial breast irradiation technique realizing the insertion of {sup 103}Pd seeds in the seroma after lumpectomy. We report the 5-year efficacy and tolerance for a cohort, pooling patients from 3 clinical trials. Methods and Materials: The trials accrued postmenopausal patients with infiltrating ductal carcinoma or ductal carcinoma in situ ≤3 cm and clear surgical margins, who were node negative, and had a planning target volume <120 cm{sup 3}. The outcomes included overall and disease-free survival and local and contralateral recurrence at 5 years. The true local recurrence rate was compared using 2-tailed paired t testsmore » for estimates calculated using the Tufts University ipsilateral breast tumor recurrence and Memorial Sloan Kettering ductal carcinoma in situ nomograms. Results: The cohort included 134 patients, and the observed local recurrence rate at a median follow-up period of 63 months was 1.2% ± 1.2%, similar to the estimate for whole breast irradiation (P=.23), significantly better than for surgery alone (relative risk 0.27; P<.001), and significantly lower than contralateral recurrence (relative risk 0.33; P<.001). The 5-year overall survival rate was 97.4% ± 1.9%, and the disease-free survival rate was 96.4% ± 2.1%. At 2 months, 42% of the patients had erythema, 20% induration, and 16% moist desquamation. The rate of mainly grade 1 telangiectasia was 22.4% at 2 years and 24% at 5 years. The rate of asymptomatic induration was 23% at 2 years and 40% at 5 years. Conclusions: The 5-year data suggest that permanent breast seed implantation is a safe accelerated partial breast irradiation option after lumpectomy for early-stage breast cancer with a tolerance profile similar to that of whole breast irradiation.« less

  11. Transperineal implantation of gold fiducial markers (gold seeds) for prostate image-guided radiation therapy: a feasible technique associated with a low risk of complications.

    PubMed

    Saad, Akram; Goldstein, Jeffrey; Lawrence, Yaacov Richard; Weiss, Ilana; Saad, Rasha; Spieler, Benjamin; Symon, Zvi

    2015-12-01

    The purpose is to describe the method, safety and efficacy of transperineal gold seed placement for image-guided radiation therapy. An ethics committee approved database was used to review records of consecutive patients from October 2008 through December 2013, who underwent transperineal implantation of three gold markers into the prostate using staged local anaesthesia and transrectal ultrasound. Seeds were counted on radiographs from CT simulation, first treatment and last treatment. Retention and use of at least three markers for kV/kV matching was considered a successful implant. A visual analogue scale (VAS) pain assessment was performed. SAS was used for data analysis. Fiducial marker placement was successful for kV/kV matching in 556/581 patients (95.7%). The procedure was aborted due to pain in two patients. Additional sedation during the procedure was required in two patients. Complications include urinary infections (2 patients, <0.5%) and transient haematuria (2 patients, <0.5%). There were no recorded calls requesting additional pain medication or delays in radiation due to complications. The number of seeds identified at simulation: 4 (2 patients), 3 (554 patients), 2 (21 patients), 1 (1 patient), 0 (1 patient). One patient with three seeds and two patients with <2 seeds had cone beam CT instead of kV/kV imaging for image guidance. No seeds were lost after simulation. The mean visual analogue pain score associated with transperineal gold seed insertion met patients' expectations (respectively 4.1 vs. 4.4 P = 0.19). Outpatient transperineal insertion of fiducials avoids the rectum, is effective, convenient, well tolerated and has few side effects.

  12. 2-(/sup 125/I)iodomelatonin binding sites in hamster brain membranes: pharmacological characteristics and regional distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, M.J.; Takahashi, J.S.; Dubocovich, M.L.

    1988-05-01

    Studies in a variety of seasonally breeding mammals have shown that melatonin mediates photoperiodic effects on reproduction. Relatively little is known, however, about the site(s) or mechanisms of action of this hormone for inducing reproductive effects. Although binding sites for (3H)melatonin have been reported previously in bovine, rat, and hamster brain, the pharmacological selectivity of these sites was never demonstrated. In the present study, we have characterized binding sites for a new radioligand, 2-(125I)iodomelatonin, in brains from a photoperiodic species, the Syrian hamster. 2-(125I)Iodomelatonin labels a high affinity binding site in hamster brain membranes. Specific binding of 2-(125I)iodomelatonin is rapid,more » stable, saturable, and reversible. Saturation studies demonstrated that 2-(125I)iodomelatonin binds to a single class of sites with an affinity constant (Kd) of 3.3 +/- 0.5 nM and a total binding capacity (Bmax) of 110.2 +/- 13.4 fmol/mg protein (n = 4). The Kd value determined from kinetic analysis (3.1 +/- 0.9 nM; n = 5) was very similar to that obtained from saturation experiments. Competition experiments showed that the relative order of potency of a variety of indoles for inhibition of 2-(125I)iodomelatonin binding site to hamster brain membranes was as follows: 6-chloromelatonin greater than or equal to 2-iodomelatonin greater than N-acetylserotonin greater than or equal to 6-methoxymelatonin greater than or equal to melatonin greater than 6-hydroxymelatonin greater than or equal to 6,7-dichloro-2-methylmelatonin greater than 5-methoxytryptophol greater than 5-methoxytryptamine greater than or equal to 5-methoxy-N,N-dimethyltryptamine greater than N-acetyltryptamine greater than serotonin greater than 5-methoxyindole (inactive).« less

  13. Quantifying spatial variability of AgI cloud seeding benefits and Ag enrichments in snow

    NASA Astrophysics Data System (ADS)

    Fisher, J.; Benner, S. G.; Lytle, M. L.; Kunkel, M. L.; Blestrud, D.; Holbrook, V. P.; Parkinson, S.; Edwards, R.

    2016-12-01

    Glaciogenic cloud seeding is an important scientific technology for enhancing water resources across in the Western United States. Cloud seeding enriches super cooled liquid water layers with plumes of silver iodide (AgI), an artificial ice nuclei. Recent studies using target-control regression analysis and modeling estimate glaciogenic cloud seeding increases snow precipitation between 3-15% annually. However, the efficacy of cloud seeding programs is difficult to assess using weather models and statistics alone. This study will supplement precipitation enhancement statistics and Weather Research and Forecasting (WRF) model outputs with ultra-trace chemistry. Combining precipitation enhancement estimates with trace chemistry data (to estimate AgI plume targeting accuracy) may provide a more robust analysis. Precipitation enhancement from the 2016 water year will be modeled two ways. First, by using double-mass curve. Annual SNOTEL data of the cumulative SWE in unseeded areas and cumulative SWE in seeded areas will be compared before, and after, the cloud seeding program's initiation in 2003. Any change in the double-mass curve's slope after 2003 may be attributed to cloud seeding. Second, WRF model estimates of precipitation will be compared to the observed precipitation at SNOTEL sites. The difference between observed and modeled precipitation in AgI seeded regions may also be attributed to cloud seeding (assuming modeled and observed data are comparable at unseeded SNOTEL stations). Ultra-trace snow chemistry data from the 2016 winter season will be used to validate whether estimated precipitation increases are positively correlated with the mass of silver in the snowpack.

  14. [Orgasm after curietherapy with permanent iodine-125 radioimplants for localized prostate cancer].

    PubMed

    Delaunay, B; Delannes, M; Salloum, A; Delavierre, D; Wagner, F; Jonca, F; Thoulouzan, M; Plante, P; Bachaud, J-M; Soulie, M; Huyghe, E

    2011-12-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy (125I permanent implantation), 241 (89%), mean age of 65 (43-80), participated in a mailed survey about sexual function after a mean time of 36 months (9-70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P=0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P=0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P=0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; P<0.001) after brachytherapy. Sixty patients (30.3%) experienced often/sometimes painful ejaculation 12.9% (n=31) before implantation (P=0.0001). Most of the patients treated by prostate brachytherapy conserved orgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  15. MicroRNA-125 family members exert a similar role in the regulation of murine hematopoiesis.

    PubMed

    Wojtowicz, Edyta E; Walasek, Marta A; Broekhuis, Mathilde J C; Weersing, Ellen; Ritsema, Martha; Ausema, Albertina; Bystrykh, Leonid V; de Haan, Gerald

    2014-10-01

    MicroRNAs (miRNAs) are crucial for proper functioning of hematopoietic stem and progenitor cells (HSPCs). Members of the miRNA-125 family (consisting of miR-125a, miR-125b1, and miR-125b2) are known to confer a proliferative advantage on cells upon overexpression, to decrease the rate of apoptosis by targeting proapoptotic genes, and to promote differentiation toward the myeloid lineage in mice. However, many distinct biological effects of the three miR-125 species have been reported as well. In the current study, we set out to assess whether the three miRNA-125s that carry identical seed sequences could be functionally different. Our data show that overexpression of each of the three miR-125 family members preserves HSPCs in a primitive state in vitro, results in a competitive advantage upon serial transplantation, and promotes skewing toward the myeloid lineage. All miR-125 family members decreased the pool of phenotypically defined Lin(-)Sca(+)Kit(+)CD48(-)CD150(+) long-term hematopoietic stem cells, simultaneously increasing the self-renewal activity upon secondary transplantation. The downregulation of miR-125s in hematopoietic stem cells abolishes these effects and impairs long-term contribution to blood cell production. The introduction of a point mutation within the miRNA-125 seed sequence abolishes all abovementioned effects and leads to the restoration of normal hematopoiesis. Our results show that all miR-125 family members are similar in function, they likely operate in a seed-sequence-dependent manner, and they induce a highly comparable hematopoietic phenotype. Copyright © 2014 ISEH - International Society for Experimental Hematology. Published by Elsevier Inc. All rights reserved.

  16. A novel MSC-seeded triphasic construct for the repair of osteochondral defects.

    PubMed

    Marquass, B; Somerson, J S; Hepp, P; Aigner, T; Schwan, S; Bader, A; Josten, C; Zscharnack, M; Schulz, R M

    2010-12-01

    Mesenchymal stem cells (MSC) are increasingly replacing chondrocytes in tissue engineering based research for treatment of osteochondral defects. The aim of this work was to determine whether repair of critical-size chronic osteochondral defects in an ovine model using MSC-seeded triphasic constructs would show results comparable to osteochondral autografting (OATS). Triphasic implants were engineered using a beta-tricalcium phosphate osseous phase, an intermediate activated plasma phase, and a collagen I hydrogel chondral phase. Autologous MSCs were used to seed the implants, with chondrogenic predifferentiation of the cells used in the cartilage phase. Osteochondral defects of 4.0 mm diameter were created bilaterally in ovine knees (n = 10). Six weeks later, half of the lesions were treated with OATS and half with triphasic constructs. The knees were dissected at 6 or 12 months. With the chosen study design we were not able to demonstrate significant differences between the histological scores of both groups. Subcategory analysis of O'Driscoll scores showed superior cartilage bonding in the 6-month triphasic group compared to the autograft group. The 12-month autograft group showed superior cartilage matrix morphology compared to the 12-month triphasic group. Macroscopic and biomechanical analysis showed no significant differences at 12 months. Autologous MSC-seeded triphasic implants showed comparable repair quality to osteochondral autografts in terms of histology and biomechanical testing. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Intravenous bolus of 125I labeled meglumine diatrizoate. Early extravascular distribution.

    PubMed

    Dean, P B; Kormano, M

    1977-05-01

    A mixture of 125I labeled meglumine diatrizoate and 131I labeled human serum albumin was injected into the femoral vein of 26 anesthetized male rats. Measurements of the activities in cardiac blood and in different tissues of the lower extremity and in the testis were performed at time intervals ranging from 5 s to 5 min after injection. The determination of tissue uptake and distribution volumes of diatrizoate showed widely differing accumulation of contrast medium. Over 50 per cent of the intravenous bolus of diatrizoate was extravascular at 40 s.

  18. Calculation of DNA strand breaks due to direct and indirect effects of Auger electrons from incorporated 123I and 125I radionuclides using the Geant4 computer code.

    PubMed

    Raisali, Gholamreza; Mirzakhanian, Lalageh; Masoudi, Seyed Farhad; Semsarha, Farid

    2013-01-01

    In this work the number of DNA single-strand breaks (SSB) and double-strand breaks (DSB) due to direct and indirect effects of Auger electrons from incorporated (123)I and (125)I have been calculated by using the Geant4-DNA toolkit. We have performed and compared the calculations for several cases: (125)I versus (123)I, source positions and direct versus indirect breaks to study the capability of the Geant4-DNA in calculations of DNA damage yields. Two different simple geometries of a 41 base pair of B-DNA have been simulated. The location of (123)I has been considered to be in (123)IdUrd and three different locations for (125)I. The results showed that the simpler geometry is sufficient for direct break calculations while indirect damage yield is more sensitive to the helical shape of DNA. For (123)I Auger electrons, the average number of DSB due to the direct hits is almost twice the DSB due to the indirect hits. Furthermore, a comparison between the average number of SSB or DSB caused by Auger electrons of (125)I and (123)I in (125)IdUrd and (123)IdUrd shows that (125)I is 1.5 times more effective than (123)I per decay. The results are in reasonable agreement with previous experimental and theoretical results which shows the applicability of the Geant-DNA toolkit in nanodosimetry calculations which benefits from the open-source accessibility with the advantage that the DNA models used in this work enable us to save the computational time. Also, the results showed that the simpler geometry is suitable for direct break calculations, while for the indirect damage yield, the more precise model is preferred.

  19. 40 CFR 1039.125 - What maintenance instructions must I give to buyers?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... disqualify those engines from in-use testing or deny a warranty claim. Do not take these maintenance steps... specified special maintenance steps to address engine operation that is not atypical, or that the... ENGINES Emission Standards and Related Requirements § 1039.125 What maintenance instructions must I give...

  20. Preferential reduction of binding of sup 125 I-iodopindolol to beta-1 adrenoceptors in the amygdala of rat after antidepressant treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ordway, G.A.; Gambarana, C.; Tejani-Butt, S.M.

    1991-05-01

    This study utilized quantitative receptor autoradiography to examine the effects of repeated administration of antidepressants to rats on the binding of the beta adrenoceptor antagonist, {sup 125}I-iodopindolol ({sup 125}I-IPIN) to either beta-1 or beta-2 adrenoceptors in various regions of brain. Antidepressants were selected to represent various chemical and pharmacological classes including tricyclic compounds (desipramine and protriptyline), monoamine oxidase inhibitors (clorgyline, phenelzine and tranylcypromine), atypical antidepressants (mianserin and trazodone) and selective inhibitors of the uptake of serotonin (citalopram and sertraline). Additionally, rats were treated with various psychotropic drugs that lack antidepressant efficacy (cocaine, deprenyl, diazepam and haloperidol). Repeated treatment of ratsmore » with desipramine, protriptyline, clorgyline, phenelzine, tranylcypromine or mianserin reduced the binding of {sup 125}I-IPIN to beta-1 adrenoceptors in many brain areas. Only in the basolateral and lateral nuclei of the amygdala did all six of these antidepressants significantly reduce {sup 125}I-IPIN binding to beta-1 adrenoceptors. In these amygdaloid nuclei, the magnitude of the reduction in the binding of {sup 125}I-IPIN caused by each of these drugs was comparable to or greater than the reduction in binding produced in any other region of brain. Reductions of binding of {sup 125}I-IPIN after antidepressant treatments were not consistently observed in the cortex, the area of brain examined most often in homogenate binding studies. Only the monoamine oxidase inhibitors caused reductions in the binding of {sup 125}I-IPIN to beta-2 adrenoceptors, and this effect was generally localized to the amygdala and hypothalamus.« less

  1. The time-dependent distribution of 125I-asialo-orosomucoid-horseradish peroxidase and 131I-immunoglobulin A among three endosomal subfractions isolated from rat liver.

    PubMed Central

    Kennedy, G; Cooper, C

    1988-01-01

    Three discrete endosomal fractions showing a time-dependent uptake of radioactive ligand were partially purified from rat liver. The 3,3'-diaminobenzidine (DAB)-induced density-shift protocol of Courtoy, Quintart & Baudhuin [(1984) J. Cell Biol. 98, 870-876] was used to study the distribution among these three endosomal fractions of two ligands with different intracellular destinations. Rats received both 125I-asialo-orosomucoid-horseradish peroxidase (125I-ASOR-HRP) and 131I-dIgA simultaneously by intraportal injection. The liver was fractionated at various times after injection, the three ligand-containing endosomal fractions (A, B and C) were separated and each was subjected separately to the DAB-induced density-shift procedure in which only vesicles containing 125I-ASOR-HRP are increased in density. Information on whether 131I-dIgA was co-localized or segregated from 125I-ASOR-HRP was obtained. The two ligands in the A fraction were partly segregated and partly co-localized, and this distribution appeared to be relatively unchanged with time. The two ligands in the B fraction were co-localized at all times studied. We have tentatively identified the B fraction as a compartment in which vesicle fusion has occurred. The two ligands in the C fraction were also partly co-localized and partly segregated, but the 131I-dIgA became increasingly segregated with time. This represents the first report of the purification of an endosomal subfraction specifically involved in the accumulation of multiple ligands. Images Fig. 7. PMID:3421920

  2. Prevention of deep vein thrombosis and pulmonary embolism. [/sup 125/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Quesne, L.P.

    1978-03-01

    The development of the /sup 125/I-fibrinogen technic in the diagnosis of postoperative deep vein thrombosis provides a valuable tool for the study of the condition itself and of the efficacy of prophylactic measures. These measures may be divided into two groups: the antistasis regimes and the antithrombotic regimes. Published reports based on the /sup 125/I-fibrinogen technic are critically reviewed. Although many regimes cause a significant diminution in the incidence of isotopically detected deep vein thrombosis, 90% of which are confined to the calf, this does not necessarily imply a similar diminution in the incidence of major pulmonary emboli, most ofmore » which arise from thrombi in the proximal segment of the lower limb veins. The origin of these proximal thrombi, with particular reference to their relationship to calf thrombi, is discussed. The reported studies of the influence of antithrombotic regimes on the incidence of pulmonary embolism are reviewed. It is concluded that a reduction in the incidence of isotopically detected deep vein thrombosis is probably accompanied by a significant reduction in the incidence of major pulmonary embolism, but further studies are required.« less

  3. Sub-Micrometer Au@PDA-125 I Particles as Theranostic Embolism Beads for Radiosensitization and SPECT/CT Monitoring.

    PubMed

    Sun, Gaofeng; Wang, Tao; Li, Xiao; Li, Danni; Peng, Ye; Wang, Xiaoke; Jia, Guorong; Su, Weiwei; Cheng, Chao; Yang, Jian; Zuo, Changjing

    2018-05-29

    Au nanoparticles (3.8 ± 0.6 nm) are assembled to sub-micrometer Au particles (186.3 ± 20.4 nm) and covered with adhesive polydopamine (PDA) as embolism beads (198.8 ± 23.2 nm). Radioactive iodine-125 is labeled to Au@PDA to introduce the function of intra-irradiation. For the therapeutic effects of Au@PDA- 125 I, Au particles sensitize the radiation to MHCC97H hepatoma cells and tumor-bearing mice. At the cellular level, after being treated with a relatively low-dose (5 Gy) γ-ray, Au-sensitized radiotherapy (RT) leads to an immediate increase of intracellular reactive oxygen species, accompanying with an increase of cell apoptosis. Due to the intra-irradiation, self-healing of RT-leaded DNA double-strand breakage is suppressed, inducing a further increase of cell apoptosis after RT treatment. Likewise, 3 cycles of sensitized RT leads to a valid control of tumor volume growth, but Au@PDA- 125 I has no harm or radioactive residual on or in the radiosensitive organs, including the thyroid, heart, lungs, liver, and spleen. Additionally, photons emitted from 125 I and high X-ray absorption of the Au element makes the beads suitable for single photon emission computed tomography/computed tomography (SPECT/CT) imaging. Therefore, as theranostic embolism beads, Au@PDA- 125 I can both enhance the therapeutic effects of external RT, and provide a real-time SPECT/CT monitoring of therapeutic time window. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Effects of hypothyroidism on vascular /sup 125/I-albumin permeation and blood flow in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tilton, R.G.; Pugliese, G.; Chang, K.

    1989-05-01

    Effects of hypothyroidism on vascular 125I-albumin permeation and on blood flow were assessed in multiple tissues of male Sprague-Dawley rats rendered hypothyroid by dietary supplementation with 0.5% (wt/wt) 2-thiouracil or by thyroidectomy. In both thiouracil-treated and thyroidectomized rats, body weights, kidney weight, arterial blood pressure, and pulse rate were decreased significantly v age-matched controls. After 10 to 12 weeks of thiouracil treatment, 125I-albumin permeation was increased significantly in the kidney, aorta, eye (anterior uvea, choroid, retina), skin, and new granulation tissue, remained unchanged in brain, sciatic nerve, and heart, and was decreased in forelimb skeletal muscle. A similar pattern wasmore » observed in thyroidectomized rats, except that increases in 125I-albumin permeation for all tissues were smaller than those observed in thiouracil-treated rats, and 125I-albumin permeation in retina did not differ from controls. In both thiouracil-treated and thyroidectomized rats, changes in blood flow (assessed with 15-microns, 85Sr-labeled microspheres) relative to the decrease in arterial blood pressure were indicative of a decrease in regional vascular resistance except in the choroid and in the kidney, in which vascular resistance was increased significantly. Glomerular filtration rate was decreased, but filtration fraction and urinary excretion of albumin remained unchanged by thiouracil treatment and thyroidectomy. These results indicate that vascular hemodynamics and endothelial cell barrier functional integrity are modulated in many different tissues by the thyroid. In view of the correspondence of hypothyroid- and diabetes-induced vascular permeability changes, these results raise the possibility that altered thyroid function in diabetes may play a role in the pathogenesis of diabetic vascular disease.« less

  5. [High non-specific binding of the beta(1) -selective radioligand 2-(125)I-ICI-H].

    PubMed

    Riemann, B; Law, M P; Kopka, K; Wagner, St; Luthra, S; Pike, V W; Neumann, J; Kirchhefer, U; Schmitz, W; Schober, O; Schäfers, M

    2003-08-01

    As results of cardiac biopsies suggest, myocardial beta(1) -adrenoceptor density is reduced in patients with chronic heart failure. However, changes in cardiac beta(2)-adrenoceptors vary. With suitable radiopharmaceuticals single photon emission computed tomography (SPECT) and positron emission tomography (PET) offer the opportunity to assess beta-adrenoceptors non-invasively. Among the novel racemic analogues of the established beta(1)-selective adrenoceptor antagonist ICI 89.406 the iodinated 2-I-ICI-H showed high affinity and selectivity to beta(1)-adrenoceptors in murine ventricular membranes. The aim of this study was its evaluation as a putative sub-type selective beta(1)-adrenergic radioligand in cardiac imaging. Competition studies in vitro and in vivo were used to investigate the kinetics of 2-I-ICI-H binding to cardiac beta-adrenoceptors in mice and rats. In addition, the radiosynthesis of 2-(125)I-ICI-H from the silylated precursor 2-SiMe(3)-ICI-H was established. The specific activity was 80 GBq/ micro mol, the radiochemical yield ranged from 70 to 80%. The unlabelled compound 2-I-ICI-H showed high beta(1)-selectivity and -affinity in the in vitro competition studies. In vivo biodistribution studies apparently showed low affinity to cardiac beta-adrenoceptors. The radiolabelled counterpart 2-(125)I-ICI-H showed a high degree of non-specific binding in vitro and no specific binding to cardiac beta(1)-adrenoceptors in vivo. Because of its high non-specific binding 2-(125)I-ICI-H is no suitable radiotracer for imaging in vivo.

  6. Effectiveness of anticancer drugs determined in nude mice inoculated with (/sup 125/I)5-iodo-2'-deoxyuridine-prelabeled human melanoma cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockshin, A.; Giovanella, B.C.; Vardeman, D.M.

    1985-04-01

    Anticancer drugs were tested on NIH-2 nude mice inoculated ip with BRO human melanoma cells, which are rapidly lethal for these hosts. Criteria for drug activity were a) increased host survival and b) an increased rate of radioactivity loss from mice bearing BRO cells prelabeled with (/sup 125/I)5-iodo-2'-deoxyuridine. Diphtheria toxin, which is selectively toxic to human cells compared to mouse cells, prolonged host survival and accelerated /sup 125/I elimination in a dose-dependent manner. Drugs that increased the rate of /sup 125/I loss compared to the rate of untreated mice also prolonged the lives of treated mice. With one exception, drugsmore » that did not accelerate /sup 125/I elimination had little or no effect on the length of survival.« less

  7. Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thaker, Nikhil G.; Kudchadker, Rajat J.; Swanson, David A.

    2014-11-01

    Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ({sup 125}I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parametersmore » were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB.« less

  8. Rectourethral fistula following LDR brachytherapy.

    PubMed

    Borchers, Holger; Pinkawa, Michael; Donner, Andreas; Wolter, Timm P; Pallua, Norbert; Eble, Michael J; Jakse, Gerhard

    2009-01-01

    Modern LDR brachytherapy has drastically reduced rectal toxicity and decreased the occurrence of rectourethral fistulas to <0.5% of patients. Therefore, symptoms of late-onset sequelae are often ignored initially. These fistulas cause severe patient morbidity and require interdisciplinary treatment. We report on the occurrence and management of a rectourethral fistula which occurred 4 years after (125)I seed implantation. Copyright 2009 S. Karger AG, Basel.

  9. Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies.

    PubMed

    Beck, P; Nicholas, H

    1975-03-01

    1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as

  10. 40 CFR 125.138 - As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... offshore oil and gas extraction facility, must I keep records and report? 125.138 Section 125.138... Intake Structures for New Offshore Oil and Gas Extraction Facilities Under Section 316(b) of the Act § 125.138 As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

  11. 40 CFR 125.138 - As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... offshore oil and gas extraction facility, must I keep records and report? 125.138 Section 125.138... Intake Structures for New Offshore Oil and Gas Extraction Facilities Under Section 316(b) of the Act § 125.138 As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

  12. 40 CFR 125.138 - As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... offshore oil and gas extraction facility, must I keep records and report? 125.138 Section 125.138... Intake Structures for New Offshore Oil and Gas Extraction Facilities Under Section 316(b) of the Act § 125.138 As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

  13. 40 CFR 125.138 - As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... offshore oil and gas extraction facility, must I keep records and report? 125.138 Section 125.138... Intake Structures for New Offshore Oil and Gas Extraction Facilities Under Section 316(b) of the Act § 125.138 As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

  14. 40 CFR 125.138 - As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... offshore oil and gas extraction facility, must I keep records and report? 125.138 Section 125.138... Intake Structures for New Offshore Oil and Gas Extraction Facilities Under Section 316(b) of the Act § 125.138 As an owner or operator of a new offshore oil and gas extraction facility, must I keep records...

  15. Binding and degradation of 125I-gastrin by plasma membranes from homogenized rat gastric mucosa.

    PubMed

    Kleveland, P M; Waldum, H L

    1986-06-01

    Binding of 125I-gastrin to the 270-30,000 g fraction from homogenized rat oxyntic mucosa was studied. 'Specific' binding was calculated by subtracting the binding at excess cold gastrin from the binding with labelled gastrin (250 pM) only. At 30 degrees C specific binding rose rapidly to a short-lived maximum before falling gradually, whereas at 15 degrees C and 0 degree C specific binding rose gradually to a higher plateau level. The reduced binding at 30 degrees C could be caused by degradation of either the tracer or the binding site or by a combination of these two events. Degradation of 125I-gastrin was evaluated by trichloroacetic acid (TCA) precipitation, fast protein liquid chromatography, and binding to a gastrin antibody (immunoreactivity). The effect of incubation on the binding site was evaluated by preincubation of the homogenate fraction before adding gastrin. In separate studies, the proteolytic activity of the homogenate fraction was studied by TCA precipitation of radioactive casein. Different enzyme inhibitors tested were virtually ineffective in preventing gastrin and casein degradation. Only lowering the incubation temperature to 15 degrees C or lower could prevent this degradation. The reduced and transient binding of 125I-gastrin at 30 degrees C most probably reflects tracer degradation. Accordingly, the gastrin binding experiments were performed at 15 degrees C. Only homogenates from the oxyntic area of the stomach bound 125I-gastrin specifically and with a Kd of 0.8 nM (Scatchard analysis). However, micromolar concentrations of unlabelled gastrin were required to inhibit half maximal binding of the tracer. The tracer binding was unaffected by secretin, slightly reduced by a CCK-9 analogue, and more markedly reduced by pentagastrin.

  16. Retention of 125I-labeled recombinant human bone morphogenetic protein-2 by biphasic calcium phosphate or a composite sponge in a rabbit posterolateral spine arthrodesis model.

    PubMed

    Louis-Ugbo, John; Kim, Hak-Sun; Boden, Scott D; Mayr, Matthew T; Li, Ronald C; Seeherman, Howard; D'Augusta, Darren; Blake, Cara; Jiao, Aiping; Peckham, Steve

    2002-09-01

    The purpose of this study was to characterize the retention kinetics of recombinant human bone morphogenetic protein-2 (rhBMP-2) applied to two calcium-based delivery matrices. Biphasic calcium phosphate (BCP) and a composite containing BCP in an absorbable collagen sponge (BCP/ACS) were evaluated using a spinal fusion model in rabbits. rhBMP-2 labeled with radioactive iodine (125I) was used as a tracer to assess in vivo retention of rhBMP-2 in the presence of these materials (nine animals per material studied). Over a 36 day study period, animals were assessed for the following: percent administered dose retained at the implant site as measured by scintigraphic imaging (counting) with a gamma camera (all animals), radiography of the implant site (all animals), radioactivity in blood and plasma (all animals), and radioactivity in the urine and feces (three animals for each material). Radioactivity data were corrected for the decay of 125I and the attenuation between the implant in vivo and the gamma camera. Differences observed between the two materials for the area under the retention vs. time profile (AUC; 988%*day for BCP vs. 1070%*day for BCP/ACS, p = 0.57) and the mean residence time (MRT; 10.2 days for BCP vs. 7.6 days for BCP/ACS, p = 0.06) were not statistically significant. Initial retention/incorporation of rhBMP-2 was slightly higher for rhBMP-2/BCP/ACS than for rhBMP-2/BCP (96.8% vs. 86.0%, p < 0.05). Animals receiving rhBMP-2/BCP showed a longer terminal retention half-life (t1/2) than did those receiving rhBMP-2/BCP/ACS (7.5 vs. 4.5 days, p < 0.05). The urinary radioactivity recovery data supported the data obtained by scintigraphy. Over the 36 day collection period, essentially complete recovery of radioactivity (dose) in urine was observed for rhBMP-2/BCP and rhBMP-2/BCP/ACS and the majority of the radioactivity (approximately 95%) was soluble in trichloroacetic acid, suggesting extensive catabolism of rhBMP-2 before renal excretion. Fecal recovery

  17. Binding of /sup 125/I-hCG to rainbow trout (Salmo gairdneri) testis in vitro. [Human Chorionic Gonadotropin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlaghecke, R.

    1983-02-01

    Homogenates of maturing rainbow trout testes show specific binding sites for /sup 125/I-labeled hCG (. /sup 125/I-labeled hCG). The binding is competitively inhibited by unlabeled hCG and by a hypophyseal extract of rainbow trout. It could be demonstrated that the tissue /sup 125/I-hCG binding specificity is restricted to the gonadal preparation. The trout testis was characterized by determining affinity and capacity from Scatchard plot analysis giving a high constant of dissociation Kd 3.65 x 10(-10)/M and a low binding capacity of 0.88 x 10(-15) M/mg tissue. The test system is markedly dependent on temperature, incubation-time, and pH. The maximum bindingmore » was found at 37 degrees during 2 hr of incubation in a buffer of pH 7.5.« less

  18. Intra-arterial bolus of 125I labeled meglumine diatrizoate. Early extravascular distribution.

    PubMed

    Dean, P B; Kormano, M

    1977-07-01

    A mixture of 125I labeled meglumine diatrizoate and 131I labeled human serum albumin was injected into the lower abdominal aorta of 30 anesthetized, laparotomized male rats. Measurements of the activities in cardiac blood and in different tissues of the hindlimbs and tests were perfomed at six time intervals ranging from 5 seconds to 2 minutes after injection, the determine early uptake and distribution volumes of diatrizoate. Concentrations and distribution volumes were initially much greater than values obtained after intravenous injection, but these differences had considerably decreased or disappeared by 2 minutes.

  19. Radioactive seed migration following parotid gland interstitial brachytherapy.

    PubMed

    Fan, Yi; Huang, Ming-Wei; Zhao, Yi-Jiao; Gao, Hong; Zhang, Jian-Guo

    To evaluate the incidence and associated factors of pulmonary seed migration after parotid brachytherapy using a novel migrated seed detection technique. Patients diagnosed with parotid cancer who underwent permanent parotid brachytherapy from January 2006 to December 2011 were reviewed retrospectively. Head and neck CT scans and chest X-rays were evaluated during routine follow-up. Mimics software and Geomagic Studio software were used for seed reconstruction and migrated seed detection from the original implanted region, respectively. Postimplant dosimetry analysis was performed after seeds migration if the seeds were still in their emitting count. Adverse clinical sequelae from seed embolization to the lung were documented. The radioactive seed implants were identified on chest X-rays in 6 patients. The incidence rate of seed migration in 321 parotid brachytherapy patients was 1.87% (6/321) and that of individual seed migration was 0.04% (6/15218 seeds). All migrated seeds were originally from the retromandibular region. No adverse dosimetric consequences were found in the target region. Pulmonary symptoms were not reported by any patient in this study. In our patient set, migration of radioactive seeds with an initial radioactivity of 0.6-0.7 mCi to the chest following parotid brachytherapy was rare. Late migration of a single seed from the central target region did not affect the dosimetry significantly, and patients did not have severe short-term complications. This study proposed a novel technique to localize the anatomical origin of the migrated seeds during brachytherapy. Our evidence suggested that placement of seeds adjacent to blood vessels was associated with an increased likelihood of seed migration to the lungs. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Why do dental implants fail? Part I.

    PubMed

    el Askary, A S; Meffert, R M; Griffin, T

    1999-01-01

    Many factors are attributed to failure of the dental implant, either directly or indirectly. The focus of this article is to define the causation of dental implant failure, as well as to present an evaluation of the implant literature regarding etiology, classification, management, and treatment of implant failures. This article will highlight the initial signs of implant failure with a view of some clinical cases in terms of classification and degrees of implant failure. Finally, a dental implant failure checklist is formulated to guide the practitioner in defining the cause of implant failure, be it infective or noninfective, and to establish percentages and frequency of occurrence. The checklist applies to all implant systems and will help to determine the factors responsible for causation and the repair procedures, whether they are at the surgical or restorative phases. The definition of implant failure is set forth in terms of ailing, failing, failed, and surviving implants, and the appropriate treatments and dispositions are outlined.

  1. Autoradiographic analysis of binding sites for sup 125 I-Bolton-Hunter-substance P in the human eye

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kieselbach, G.F.; Ragaut, R.; Knaus, H.G.

    1990-07-01

    Substance P is known to exert potent effects in peripheral tissues, and is thought to be important for ocular function. The mechanism of action of substance P in the human eye is not known. As a basis for biochemical characterization specific binding of {sup 125}I-Bolton-Hunter-substance P was demonstrated in the human eye using autoradiographic methods. Biochemical characterization on slide-mounted tissue preparations showed that binding was saturable with a KD of 0.27 +/- 0.1 nmol/l. Specific binding occurred at comparable autoradiographic densities to both human retina and choroid. Substance P and its carboxyterminal fragment, substance P(3-11), were shown to be highlymore » potent in binding competition experiments against {sup 125}I-Bolton-Hunter-substance P. Similar concentrations of substance P(1-9), neurokinin A and neurokinin B failed to significantly alter specific binding of {sup 125}I-Bolton-Hunter-substance P. The results indicate expression of high affinity substance P binding sites in human retina and choroid.« less

  2. Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

    PubMed

    Zhang, Guobin; Sun, Qiyuan; Jiang, Shan; Yang, Zhiyong; Ma, Xiaodong; Jiang, Haisong

    2017-11-01

    Postimplant validation is an indispensable part in the brachytherapy technique. It provides the necessary feedback to ensure the quality of operation. The ability to pick implanted seed relates directly to the accuracy of validation. To address it, an automatic approach is proposed for picking implanted brachytherapy seeds in 3D CT images. In order to pick seed configuration (location and orientation) efficiently, the approach starts with the segmentation of seed from CT images using a thresholding filter which based on gray-level histogram. Through the process of filtering and denoising, the touching seed and single seed are classified. The true novelty of this approach is found in the application of the canny edge detection and improved concave points matching algorithm to separate touching seeds. Through the computation of image moments, the seed configuration can be determined efficiently. Finally, two different experiments are designed to verify the performance of the proposed approach: (1) physical phantom with 60 model seeds, and (2) patient data with 16 cases. Through assessment of validated results by a medical physicist, the proposed method exhibited promising results. Experiment on phantom demonstrates that the error of seed location and orientation is within ([Formula: see text]) mm and ([Formula: see text])[Formula: see text], respectively. In addition, the most seed location and orientation error is controlled within 0.8 mm and 3.5[Formula: see text] in all cases, respectively. The average process time of seed picking is 8.7 s per 100 seeds. In this paper, an automatic, efficient and robust approach, performed on CT images, is proposed to determine the implanted seed location as well as orientation in a 3D workspace. Through the experiments with phantom and patient data, this approach also successfully exhibits good performance.

  3. Expression levels of the innate response gene RIG-I and its regulators RNF125 and TRIM25 in HIV-1-infected adult and pediatric individuals.

    PubMed

    Britto, Alan M A; Amoedo, Nívea D; Pezzuto, Paula; Afonso, Adriana O; Martínez, Ana M B; Silveira, Jussara; Sion, Fernando S; Machado, Elizabeth S; Soares, Marcelo A; Giannini, Ana L M

    2013-07-31

    TLRs (Toll-like receptors) and RLRs (RIG-I-like receptors) mediate innate immune responses by detecting microorganism invasion. RIG-I activation results in the production of interferon (IFN) type 1 and IFN responsive genes (ISGs). As the ubiquitin ligases RNF125 and TRIM25 are involved in regulating RIG-I function, our aim was to assess whether the levels of these three genes vary between healthy and HIV-infected individuals and whether these levels are related to disease progression. Gene expression analyses for RIG-I, RNF125, and TRIM25 were performed for HIV-infected adults and the children's peripheral blood mononuclear cells (PBMCs). Reverse transcription-quantitative PCRs (RT-qPCRs) were performed in order to quantify the expression levels of RIG-I, RNF125 and TRIM25 from PBMCs purified from control or HIV-infected individuals. Controls express higher levels of the three genes when compared to HIV-infected patients. These expressions are clearly distinct between healthy and progressors, and are reproduced in adults and children. In controls, RNF125 is the highest expressed gene, whereas in progressors, RIG-I is either the highest expressed gene or is expressed similarly to RNF125 and TRIM25. A pattern of expression of RIG-I, RNF125, and TRIM25 genes in HIV patients is evident. The high expression of RNF125 in healthy individuals reflects the importance of keeping RIG-I function off, inhibiting unnecessary IFN production. Consistent with this assumption, RNF125 levels are lower in HIV patients and importantly, the RNF125/RIG-I ratio is lower in patients who progress to AIDS. Our results might help to predict disease progression and unveil the role of poorly characterized host genes during HIV infection.

  4. Ganglioside inhibition of sup 125 I-plasmin binding to colorectal carcinoma cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liepkalns, V.A.; Burtin, M.C.; Correc, P.

    1990-01-01

    The pre-incubation of human colorectal carcinoma cells SW 1116 with 25 to 100 uM purified gangliosides resulted in 35-60% inhibition of specific {sup 125}I-plasmin binding to the cell surface. After 5 to 6 days in culture, tumor cells were pre-incubated at 4 degrees for 1 to 4 h followed by post-incubation with {sup 125}I-plasmin by techniques previously described. At 25 uM the capacity for inhibition of plasmin binding was GT1b greater than GQ1b greater than or equal to GD1a greater than GM1 less than or equal to GgOse 4Cer. Thus a terminal sialyl moiety appears to be necessary (p lessmore » than 0.05) although exogenous N-acetyl neuraminic acid was ineffective (p greater than 0.05), indicating a role for the lipid portion of the ganglioside. Other (glyco)lipids such as sphingosine, fucolipid H-1 and sulfatide were without significant effect. The inhibition could not be reversed by the presence of 10 mM Ca+2, EDTA, pre-treatment of the cell with carboxypeptidase or pretreatment of plasmin with neuraminidases. The inhibition was however reversed by post-incubation in control medium without exogenous ganglioside. Cell counts determined prior to, and after ganglioside incubation showed that the effect was not due to cell death or detachment from the culture surface. The dissociation constant for {sup 125}I-plasmin binding was 5.6 x 10(-8) M (700,000 sites/cell), but in the presence of trisialoganglioside (GT1b), Scatchard plots suggested diversification of binding sites with 280,000 sites/cell at Kd 2.6 x 10(-8) M and 820,000 sites/cell at Kd 2.1 x 10(-7) M. Another interpretation of the Scatchard plot in the presence of ganglioside was that the glycolipid imposed negative cooperativity on plasmin binding to the cell surface. These results suggest that certain gangliosides can affect tumor cell invasiveness by altering protease binding to the cell surface.« less

  5. /sup 125/I iothalamate an ideal marker for glomerular filtration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Odlind, B.; Haellgren, R.S.; Sohtell, M.

    1985-01-01

    The triiodinated angiographic contrast medium, iothalamate (usually labelled /sup 125/I), has been used extensively as a marker for glomerular filtration. The authors have studied the renal handling of /sup 125/I iothalamate (IOT) in vivo and in vitro in several species. In renal cortical slices from chicken, rabbit, rat, and monkey, the tissue-to-medium ratio of IOT was twice that of /sup 51/Cr-EDTA (EDTA) at 37 degrees C; a difference that was abolished at 0 degree C and markedly reduced by added o-iodohippurate or iodipamide. In five chickens the steady-state renal clearance of IOT (CIOT) was twice that of EDTA (CEDTA) ormore » /sup 3/H inulin (C1); a difference that was abolished by administration of 100 mg/kg/hr of novobiocin, an organic anion transport inhibitor. CEDTA was similar to C1 before as well as after transport inhibition. Utilizing the Sperber technique the mean apparent tubular excretion fraction (ATEF) of IOT was 8%, while that of EDTA was 1%. After novobiocin coinfusion (new steady-state) ATEFIOT was significantly reduced and not different from that of EDTA (-1%). In the same animals the total urinary recovery of IOT was 84 and 57% before and after novobiocin, respectively, while corresponding values for EDTA was unchanged by the inhibitor. In seven rats the renal extraction of IOT was reduced from 29 to 17% by coinfusion of probenecid (5 mg/kg/hr). Corresponding extractions were 82 to 34% and 22% (unchanged) for PAH and EDTA, respectively.« less

  6. Health-Related Quality of Life up to Six Years After {sup 125}I Brachytherapy for Early-Stage Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roeloffzen, Ellen M.A., E-mail: E.M.A.Roeloffzen@UMCUtrecht.n; Lips, Irene M.; Gellekom, Marion P.R. van

    2010-03-15

    Purpose: Health-related quality of life (HRQOL) after prostate brachytherapy has been extensively described in published reports but hardly any long-term data are available. The aim of the present study was to prospectively assess long-term HRQOL 6 years after {sup 125}I prostate brachytherapy. Methods and Materials: A total of 127 patients treated with {sup 125}I brachytherapy for early-stage prostate cancer between December 2000 and June 2003 completed a HRQOL questionnaire at five time-points: before treatment and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Researchmore » and Treatment of Cancer core questionnaire (EORTCQLQ-C30), and the tumor-specific EORTC prostate cancer module (EORTC-PR25). A change in a score of >=10 points was considered clinically relevant. Results: Overall, the HRQOL at 6 years after {sup 125}I prostate brachytherapy did not significantly differ from baseline. Although a statistically significant deterioration in HRQOL at 6 years was seen for urinary symptoms, bowel symptoms, pain, physical functioning, and sexual activity (p <.01), most changes were not clinically relevant. A statistically significant improvement at 6 years was seen for mental health, emotional functioning, and insomnia (p <.01). The only clinically relevant changes were seen for emotional functioning and sexual activity. Conclusion: This is the first study presenting prospective HRQOL data up to 6 years after {sup 125}I prostate brachytherapy. HRQOL scores returned to approximately baseline values at 1 year and remained stable up to 6 years after treatment. {sup 125}I prostate brachytherapy did not adversely affect patients' long-term HRQOL.« less

  7. Immediate direct-to-implant breast reconstruction using anatomical implants.

    PubMed

    Kim, Sung-Eun; Jung, Dong-Woo; Chung, Kyu-Jin; Lee, Jun Ho; Kim, Tae Gon; Kim, Yong-Ha; Lee, Soo Jung; Kang, Su Hwan; Choi, Jung Eun

    2014-09-01

    In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  8. Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy.

    PubMed

    Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y

    2001-05-01

    In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.

  9. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  10. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  11. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  12. 40 CFR 125.137 - As an owner or operator of a new offshore oil and gas extraction facility, must I perform...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... offshore oil and gas extraction facility, must I perform monitoring? 125.137 Section 125.137 Protection of... operator of a new offshore oil and gas extraction facility, must I perform monitoring? As an owner or operator of a new offshore oil and gas extraction facility, you will be required to perform monitoring to...

  13. Optimal matching for prostate brachytherapy seed localization with dimension reduction.

    PubMed

    Lee, Junghoon; Labat, Christian; Jain, Ameet K; Song, Danny Y; Burdette, Everette C; Fichtinger, Gabor; Prince, Jerry L

    2009-01-01

    In prostate brachytherapy, x-ray fluoroscopy has been used for intra-operative dosimetry to provide qualitative assessment of implant quality. More recent developments have made possible 3D localization of the implanted radioactive seeds. This is usually modeled as an assignment problem and solved by resolving the correspondence of seeds. It is, however, NP-hard, and the problem is even harder in practice due to the significant number of hidden seeds. In this paper, we propose an algorithm that can find an optimal solution from multiple projection images with hidden seeds. It solves an equivalent problem with reduced dimensional complexity, thus allowing us to find an optimal solution in polynomial time. Simulation results show the robustness of the algorithm. It was validated on 5 phantom and 18 patient datasets, successfully localizing the seeds with detection rate of > or = 97.6% and reconstruction error of < or = 1.2 mm. This is considered to be clinically excellent performance.

  14. Preoperative HE4 and ROMA values do not improve the CA125 diagnostic value for borderline tumors of the ovary (BOT) - a study of the TOC Consortium.

    PubMed

    Braicu, Elena Ioana; Van Gorp, Toon; Nassir, Mani; Richter, Rolf; Chekerov, Radoslav; Gasimli, Khayal; Timmerman, Dirk; Vergote, Ignace; Sehouli, Jalid

    2014-01-01

    Borderline tumors of the ovary (BOT) are a distinct entity of ovarian tumors, characterized by lack of stromal invasion. Recent studies postulated that the presence of invasive implants, incomplete staging, fertility sparing surgery and residual tumor after surgery are major prognostic factors for BOT. There are no biomarkers that can predict BOT or the presence of invasive implants. The aim of our study was to assess the value of CA125 and HE4 alone, or within ROMA score for detecting BOT, and for predicting the presence of invasive implants. Retrospective, monocentric study on 167 women diagnosed with BOT or benign ovarian masses. Serum HE4, CA125 levels and ROMA were assessed preoperatively. Due to low number of BOT with invasive implants, we performed an unmatched analysis (consecutive patients) and a matched analysis (according to age and histology) to compare BOT with invasive implants, BOT without invasive implants and benign disease. There were no significant differences in the HE4 and CA125 expressions in the three groups of patients (p = 0.984 and p = 0.141, respectively). The ROC analysis showed that CA125 alone is superior to ROMA and HE4 in discriminating patients with BOT with invasive implants from patients with benign diseases and BOT without invasive implants. A newly established score, ROMABOT, did not perform better than ROMA. The analysis of the matched groups revealed similar results as the analysis of all samples. Both HE4 and CA125 are not reliable biomarkers for the diagnosis of BOT or for predicting the presence of invasive implants.

  15. Radioiodination and preclinical evaluation of 4-benzyl-1-(3-[125I]-iodobenzylsulfonyl)piperidine as a breast tumor imaging tracer in mouse.

    PubMed

    Sadeghzadeh, Masoud; Alirezapour, Behrouz; Charkhlooie, Ghorban Ali; Baghery, Maryam Keshavarz; Khorouti, Amir

    2017-05-01

    4-Benzyl-1-(3-iodobenzylsulfonyl)piperidine, 4-B-IBSP, has shown high-binding affinity to both sigma (σ) receptors in our previous work. In current study, radiolabeling and preclinical evaluation of 4-benzyl-1-(3-[ 125 I]-iodobenzylsulfonyl)piperidine, 4-B-[ 125 I]IBSP, in human ductal breast carcinoma (T47D) cells and in breast adenocarcinoma-bearing BALB/c mice are described. Radioiodination of this new σ ligand was performed by a palladium-catalyzed stannylation approach followed by oxidative iododestannylation reaction using Iodo-Gen. Competition-binding assays for binding of 4-B-[ 125 I]IBSP to guinea pig brain membranes and to T47D cells were performed with known σ ligands. The selectivity and binding characteristics (B max and K d ) were analyzed. In vitro stability and in vivo blood metabolism studies were also evaluated. Moreover, biodistribution studies were performed in normal and into the tumor-bearing mice at interval time points post-injection (p.i.). Both in vitro and in vivo blockade experiments were done in the presence of the σ receptors blocking agents. Radioiodinated ligand was obtained in high yield and high specific activity. The σ inhibition constants (K i , nM) for 4-(3-iodobenzyl)-1-(benzylsulfonyl)piperazine (4-IBBSPz), (+)-pentazocine, haloperidol, DTG, and 4-B-IBSP were 1.37 ± 0.19, 3.90 ± 0.77, 2.69 ± 0.33, 30.62 ± 2.01, and 0.61 ± 0.05, respectively. 4-B-[ 125 I]IBSP bound to σ receptor sites preferably to very high-affinity binding sites on T47D cells. The radioligand showed acceptable in vitro and in vivo stabilities in the blood pool. However, in vivo biodistribution studies in normal Swiss albino mice revealed fast clearance of 4-B-[ 125 I]IBSP from blood and the other normal organs. Biodistribution experiments of 4-B-[ 125 I]IBSP in breast adenocarcinoma tumor-bearing BALB/c mice showed a relatively high tumor uptake at 30 min p.i. (4.13 ± 0.95) that reaches to 1.57 ± 0.24 even after 240

  16. Influence of source batch S{sub K} dispersion on dosimetry for prostate cancer treatment with permanent implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuñez-Cumplido, E., E-mail: ejnc-mccg@hotmail.com; Hernandez-Armas, J.; Perez-Calatayud, J.

    2015-08-15

    Purpose: In clinical practice, specific air kerma strength (S{sub K}) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with {sup 125}I and {sup 103}Pd sources; in fact, commercial TPS provide only one S{sub K} input value for all implanted sources and the certified shipment average is typically used. However, the value for S{sub K} is dispersed: this dispersion is not only due to the manufacturing process and variation between different source batches but also due to the classification of sources into different classes according to their S{sub K} values. The purpose of this work is tomore » examine the impact of S{sub K} dispersion on typical implant parameters that are used to evaluate the dose volume histogram (DVH) for both planning target volume (PTV) and organs at risk (OARs). Methods: The authors have developed a new algorithm to compute dose distributions with different S{sub K} values for each source. Three different prostate volumes (20, 30, and 40 cm{sup 3}) were considered and two typical commercial sources of different radionuclides were used. Using a conventional TPS, clinically accepted calculations were made for {sup 125}I sources; for the palladium, typical implants were simulated. To assess the many different possible S{sub K} values for each source belonging to a class, the authors assigned an S{sub K} value to each source in a randomized process 1000 times for each source and volume. All the dose distributions generated for each set of simulations were assessed through the DVH distributions comparing with dose distributions obtained using a uniform S{sub K} value for all the implanted sources. The authors analyzed several dose coverage (V{sub 100} and D{sub 90}) and overdosage parameters for prostate and PTV and also the limiting and overdosage parameters for OARs, urethra and rectum. Results: The parameters analyzed followed a Gaussian distribution for the entire set of computed dosimetries. PTV and

  17. Evaluating the Phoenix definition of biochemical failure after (125)I prostate brachytherapy: Can PSA kinetics distinguish PSA failures from PSA bounces?

    PubMed

    Thompson, Anna; Keyes, Mira; Pickles, Tom; Palma, David; Moravan, Veronika; Spadinger, Ingrid; Lapointe, Vincent; Morris, W James

    2010-10-01

    To evaluate the prostate-specific antigen (PSA) kinetics of PSA failure (PSAf) and PSA bounce (PSAb) after permanent (125)I prostate brachytherapy (PB). The study included 1,006 consecutive low and "low tier" intermediate-risk patients treated with (125)I PB, with a potential minimum follow-up of 4 years. Patients who met the Phoenix definition of biochemical failure (nadir + 2 ng/mL(-1)) were identified. If the PSA subsequently fell to ≤0.5 ng/mL(-1)without intervention, this was considered a PSAb. All others were scored as true PSAf. Patient, tumor and dosimetric characteristics were compared between groups using the chi-square test and analysis of variance to evaluate factors associated with PSAf or PSAb. Median follow-up was 54 months. Of the 1,006 men, 57 patients triggered the Phoenix definition of PSA failure, 32 (56%) were true PSAf, and 25 PSAb (44%). The median time to trigger nadir + 2 was 20.6 months (range, 6-36) vs. 49 mo (range, 12-83) for PSAb vs. PSAf groups (p < 0.001). The PSAb patients were significantly younger (p < 0.0001), had shorter time to reach the nadir (median 6 vs. 11.5 months, p = 0.001) and had a shorter PSA doubling time (p = 0.05). Men younger than age 70 who trigger nadir +2 PSA failure within 38 months of implant have an 80% likelihood of having PSAb and 20% chance of PSAf. With adequate follow-up, 44% of PSA failures by the Phoenix definition in our cohort were found to be benign PSA bounces. Our study reinforces the need for adequate follow-up when reporting PB PSA outcomes, to ensure accurate estimates of treatment efficacy and to avoid unnecessary secondary interventions. 2010. Published by Elsevier Inc. All rights reserved.

  18. Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration

    PubMed Central

    KarimAghaloo, Z.; Abolmaesumi, P.; Ahmidi, N.; Chen, T.K.; Gobbi, D. G.; Fichtinger, G.

    2010-01-01

    In prostate brachytherapy, a transrectal ultrasound (TRUS) will show the prostate boundary but not all the implanted seeds, while fluoroscopy will show all the seeds clearly but not the boundary. We propose an intensity-based registration between TRUS images and the implant reconstructed from uoroscopy as a means of achieving accurate intra-operative dosimetry. The TRUS images are first filtered and compounded, and then registered to the uoroscopy model via mutual information. A training phantom was implanted with 48 seeds and imaged. Various ultrasound filtering techniques were analyzed, and the best results were achieved with the Bayesian combination of adaptive thresholding, phase congruency, and compensation for the non-uniform ultrasound beam profile in the elevation and lateral directions. The average registration error between corresponding seeds relative to the ground truth was 0.78 mm. The effect of false positives and false negatives in ultrasound were investigated by masking true seeds in the uoroscopy volume or adding false seeds. The registration error remained below 1.01 mm when the false positive rate was 31%, and 0.96 mm when the false negative rate was 31%. This fully automated method delivers excellent registration accuracy and robustness in phantom studies, and promises to demonstrate clinically adequate performance on human data as well. Keywords: Prostate brachytherapy, Ultrasound, Fluoroscopy, Registration. PMID:21152376

  19. Experimental Acquisitions with ^125I on a Small Animal SPECT Device*

    NASA Astrophysics Data System (ADS)

    Knott, Kevin; Welsh, Robert E.; Bradley, Eric L.; Saha, Margaret S.; Kross, Brian; Majewski, Stan; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randolph

    2001-04-01

    We have performed single photon emission computed tomography (SPECT) studies on a small animal scanning system for which the detector employed position sensitive phototubes (125 mm dia. Hamamatsu R3292 and 18 x 18 mm Hamamatsu M-64) coupled to pixelated scintillators CsI(Tl) and CsI(Na) Phantom acquisitions were used to investigate the effects of angular sampling and scan time on reconstructed image quality and noise. Results from these studies will be described and extended to in vivo studies with small animals. *Supported in part by the Thomas F. and Kate Miller Jeffress Trust, the Department of Energy, The American Diabetes Association, The National Science Foundation, the Howard Hughes Foundation and the Virginia Commonwealth Health Research Board.

  20. Correlation of 125I-LSD autoradiographic labeling with serotonin voltage clamp responses in Aplysia neurons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, M.L.; Kadan, M.J.; Hartig, P.R.

    Autoradiographic receptor binding studies using 125I-LSD (2-(125I)lysergic acid diethyamide) revealed intense labelling on the soma of a symmetrically located pair of cells in the abdominal ganglion of Aplysia californica. This binding was blocked by micromolar concentrations of serotonin and lower concentrations of the serotonergic antagonists, cyproheptadine and mianserin. Electrophysiological investigation of responses to serotonin of neurons in the left upper quadrant, where one of the labeled neurons is located, revealed a range of serotonin responses. Cells L3 and L6 have a K+ conductance increase in response to serotonin that is not blocked by cyproheptadine or mianserin. Cells L2 and L4more » have a biphasic response to serotonin: a Na+ conductance increase, which can be blocked by cyproheptadine and mianserin, followed by a voltage dependent Ca2+ conductance which is blocked by Co2+ but not the serotonergic antagonists. Cell L1, and its symmetrical pair, R1, have in addition to the Na+ and Ca2+ responses observed in L2 and L4, a Cl- conductance increase blocked by LSD, cyproheptadine and mianserin. LSD had little effect on the other responses. The authors conclude that the symmetrically located cells L1 and R1 have a Cl- channel linked to a cyproheptadine- and mianserin-sensitive serotonin receptor that is selectively labelled by 125I-LSD. This receptor has many properties in common with the mammalian serotonin 1C receptor.« less

  1. Etude microdosimetrique de l'influence des materiaux sur l'efficacite biologique d'une source d'iode-125

    NASA Astrophysics Data System (ADS)

    Taschereau, Richard

    Cette these concerne les implants permanents pour la prostate. Les isotopes employes, le 103Pd et l'125I, semblent produire les memes resultats cliniques: le premier a cause d'une radiation plus efficace et le second a cause de sa demi-vie plus longue. La recherche utilise le cadre theorique de la microdosimetrie et des simulations Monte Carlo. Elle propose d'employer le spectre d'ejection dans le calcul de l'efficacite; ce changement fait passer l'efficacite relative du 103Pd de 10% a 5%. Elle montre ensuite qu'il est possible d'ameliorer l'efficacite de la radiation de 125I par l'exploitation des rayons X caracteristiques de la capsule. Une source amelioree faite de molybdene et d'yttrium est donnee en exemple. Elle procure une radiation de 5--7% plus efficace, ce qui surclasse les deux sources existantes. Les applications ne se limitent pas au traitement de la prostate; le traitement du melanome oculaire et la curietherapie endovasculaire pourraient en beneficier.

  2. Characterization of an Mg-implanted GaN p-i-n Diode

    DTIC Science & Technology

    2016-03-31

    unintentionally doped GaN layer was grown by metal organic chemical vapor deposition (MOCVD) on a n+ Ga -face c-oriented GaN substrate. The as-grown MOCVD film...their proper lattice sites. In the case of Mg implanted GaN , the Mg must replace Ga to result in p-type material. In many other semiconductor...Characterization of an Mg-implanted GaN p-i-n Diode Travis J. Anderson, Jordan D. Greenlee, Boris N. Feigelson, Karl D. Hobart, and Francis J

  3. SU-F-T-09: In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Therriault-Proulx, F; Bruno, T; Beddar, S

    Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading.more » A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.« less

  4. Consistent individual differences in seed disperser quality in a seed-eating fish.

    PubMed

    Pollux, Bart J A

    2017-01-01

    Animal-mediated seed dispersal (zoochory) is considered to be an important mechanism regulating biological processes at larger spatial scales. To date, intra-specific variation in seed disperser quality within seed-dispersing animals has not been studied. Here, I employed seed feeding trials to quantify individual differences in disperser quality within the common carp (Cyprinus carpio) using seeds of two aquatic plants: unbranched bur-reed (Sparganium emersum, Sparganiaceae) and arrowhead (Sagittaria sagittifolia, Alismataceae). I found substantial variation among carp individuals in their propensity to ingest seeds and their ability to digest them, resulting in up to 31-fold differences in the probability of seed dispersal. In addition, there were significant differences in the time that seeds are retained in their digestive systems, generating a twofold difference in the maximum distance over which they can potentially disperse seeds. I propose that seed-eating animal species consist of individuals that display continuous variation in disperser quality, with at one end of the continuum individuals that are likely to eat seeds, pass them unharmed through their digestive tract and transport them over large distances to new locations (i.e. high-quality seed dispersers) and at the other end individuals that rarely eat seeds, destroy most of the ones they ingest and transport the few surviving seeds over relatively short distances (low-quality seed dispersers). Although individual differences in seed dispersal quality could be the result of a variety of factors, these results underline the ecological and evolutionary potential of such variation for both plants and animals.

  5. SU-G-IeP1-01: A Novel MRI Post-Processing Algorithm for Visualization of the Prostate LDR Brachytherapy Seeds and Calcifications Based On B0 Field Inhomogeneity Correction and Hough Transform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nosrati, R; Sunnybrook Health Sciences Centre, Toronto, Ontario; Soliman, A

    Purpose: This study aims at developing an MRI-only workflow for post-implant dosimetry of the prostate LDR brachytherapy seeds. The specific goal here is to develop a post-processing algorithm to produce positive contrast for the seeds and prostatic calcifications and differentiate between them on MR images. Methods: An agar-based phantom incorporating four dummy seeds (I-125) and five calcifications of different sizes (from sheep cortical bone) was constructed. Seeds were placed arbitrarily in the coronal plane. The phantom was scanned with 3T Philips Achieva MR scanner using an 8-channel head coil array. Multi-echo turbo spin echo (ME-TSE) and multi-echo gradient recalled echomore » (ME-GRE) sequences were acquired. Due to minimal susceptibility artifacts around seeds, ME-GRE sequence (flip angle=15; TR/TE=20/2.3/2.3; resolution=0.7×0.7×2mm3) was further processed.The induced field inhomogeneity due to the presence of titaniumencapsulated seeds was corrected using a B0 field map. B0 map was calculated using the ME-GRE sequence by calculating the phase difference at two different echo times. Initially, the product of the first echo and B0 map was calculated. The features corresponding to the seeds were then extracted in three steps: 1) the edge pixels were isolated using “Prewitt” operator; 2) the Hough transform was employed to detect ellipses approximately matching the dimensions of the seeds and 3) at the position and orientation of the detected ellipses an ellipse was drawn on the B0-corrected image. Results: The proposed B0-correction process produced positive contrast for the seeds and calcifications. The Hough transform based on Prewitt edge operator successfully identified all the seeds according to their ellipsoidal shape and dimensions in the edge image. Conclusion: The proposed post-processing algorithm successfully visualized the seeds and calcifications with positive contrast and differentiates between them according to their shapes. Further

  6. New design of experiment combined with UV-Vis spectroscopy for extraction and estimation of polyphenols from Basil seeds, Red seeds, Sesame seeds and Ajwan seeds

    NASA Astrophysics Data System (ADS)

    Mabood, Fazal; Gilani, Syed Abdullah; Hussain, Javid; Alshidani, Sulaiman; Alghawi, Said; Albroumi, Mohammed; Alameri, Saif; Jabeen, Farah; Hussain, Zahid; Al-Harrasi, Ahmed; Al Abri, Zahra K. M.; Farooq, Saima; Naureen, Zakira; Hamaed, Ahmad; Rasul Jan, M.; Shah, Jasmin

    2017-05-01

    New experimental designs for the extraction of polyphenols from different seeds including Basil seed, Red seed, Sesame seeds and Ajwan seeds were investigated. Four variables the concentration and volume of methanol and NaOH solutions as well as the temperature and time of extraction were varied to see their effect on total phenol extraction. The temperature was varied in the range from 25 °C to 200 °C while the time in the range from 30 to 200 minutes. Response surface methodology was used to optimize the extraction parameters. The estimation of polyphenols was measured through phenols reduction UV-Vis spectroscopic method of phosphotungstic-phosphomolybdic acids (Folin-Ciocalteu's reagent). Calibration curve was made by using tannic acid as a polyphenols standard in the concentration range from 0.1 to 10 ppm. The regression line obtained shows the value of correlation coefficient i.e. R = 0.930 and Root mean square error of cross validation (RMSEC) value of 0.0654. The Basil seeds were found containing the highest amount of total phenols i.e. 785.76 mg/100 g. While the Sesame seeds having the least amount i.e. 33.08 mg/100 g. The Ajwan seeds and the Red seeds are containing the medium amounts i.e. 379 mg/100 g and 220.54 mg/100 g respectively.

  7. New design of experiment combined with UV-Vis spectroscopy for extraction and estimation of polyphenols from Basil seeds, Red seeds, Sesame seeds and Ajwan seeds.

    PubMed

    Mabood, Fazal; Gilani, Syed Abdullah; Hussain, Javid; Alshidani, Sulaiman; Alghawi, Said; Albroumi, Mohammed; Alameri, Saif; Jabeen, Farah; Hussain, Zahid; Al-Harrasi, Ahmed; Al Abri, Zahra K M; Farooq, Saima; Naureen, Zakira; Hamaed, Ahmad; Rasul Jan, M; Shah, Jasmin

    2017-05-05

    New experimental designs for the extraction of polyphenols from different seeds including Basil seed, Red seed, Sesame seeds and Ajwan seeds were investigated. Four variables the concentration and volume of methanol and NaOH solutions as well as the temperature and time of extraction were varied to see their effect on total phenol extraction. The temperature was varied in the range from 25°C to 200°C while the time in the range from 30 to 200minutes. Response surface methodology was used to optimize the extraction parameters. The estimation of polyphenols was measured through phenols reduction UV-Vis spectroscopic method of phosphotungstic-phosphomolybdic acids (Folin-Ciocalteu's reagent). Calibration curve was made by using tannic acid as a polyphenols standard in the concentration range from 0.1 to 10ppm. The regression line obtained shows the value of correlation coefficient i.e. R=0.930 and Root mean square error of cross validation (RMSEC) value of 0.0654. The Basil seeds were found containing the highest amount of total phenols i.e. 785.76mg/100g. While the Sesame seeds having the least amount i.e. 33.08mg/100g. The Ajwan seeds and the Red seeds are containing the medium amounts i.e. 379mg/100g and 220.54mg/100g respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Estimation of Rapidly Exchangeable Cellular Thyroxine from the Plasma Disappearance Curves of Simultaneously Administered Thyroxine-131I and Albumin-125I*

    PubMed Central

    Oppenheimer, Jack H.; Bernstein, Gerald; Hasen, Julian

    1967-01-01

    A mathematical analysis of the plasma disappearance curves of simultaneously injected thyroxine-131I and albumin-125I allows the development of simple formulas for estimating the pool size and transfer kinetics of rapidly exchangeable intracellular thyroxine in man. Evidence is presented that the early distribution kinetics of albumin-125I can be used to represent the expansion of the thyroxine-131I-plasma protein complex into the extracellular compartment. Calculations indicate that approximately 37% of total body extrathyroidal thyroxine is within such exchangeable tissue stores. The average cellular clearance of thyroxine is 42.7 ml per minute, a value far in excess of the metabolic clearance of this hormone. Results of external measurements over the hepatic area and studies involving hepatic biopsies indicate that the liver is an important but probably not the exclusive component of the intracellular compartment. The partition of thyroxine between cellular and extracellular compartments is determined by the balance of tissue and plasma protein binding factors. The fractional transfer constants are inversely related to the strength of binding of each compartment and directly proportional to the permeability characteristic of the hypothetical membrane separating compartments. Appropriate numerical values for these factors are assigned. An increased fractional entrance of thyroxine-131I into the cellular compartment was noted in a patient with congenital decrease in the maximal binding capacity of thyroxine-binding globulin and in three patients after the infusion of 5,5-diphenylhydantoin. Decreased intracellular space and impaired permeability characteristics were observed in five patients with hepatic disease. Studies of the rate of entrance of thyroxine-131I and albumin-125I into the pleural effusion of a patient with congestive heart failure suggested that transcapillary passage of thyroxine independent of its binding protein is not a predominant factor in the

  9. Binding and internalization in vivo of (/sup 125/I)hCG in Leydig cells of the rat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermo, L.; Lalli, M.

    1988-01-01

    The present study was performed to demonstrate the binding, mode of uptake, pathway and fate of iodinated human chorionic gonadotropin ((/sup 125/I)hCG) by Leydig cells in vivo using electron microscope radioautography. Following a single injection of (/sup 125/I)hCG into the interstitial space of the testis, the animals were fixed by perfusion with glutaraldehyde at 20 minutes, 1, 3, 6 and 24 hours. The electron microscope radioautographs demonstrated a prominent and qualitatively similar binding of the labeled hCG on the microvillar processes of the Leydig cells at 20 minutes, 1, 3, and 6 hours. The specificity of the (/sup 125/I)hCG bindingmore » was determined by injecting a 100-fold excess of unlabeled hormone concurrently with the labeled hormone. Under these conditions, the surface, including the microvillar processes of Leydig cells, was virtually unlabeled, indicating that the binding was specific and receptor-mediated. In animals injected with labeled hCG and sacrificed 20 minutes later, silver grains were also seen overlying the limiting membrane of large, uncoated surface invaginations and large subsurface vacuoles with an electron-lucent content referred to as endosomes. A radioautographic reaction was also seen within multivesicular bodies with a pale stained matrix. At 1 hour, silver grains appeared over dense multivesicular bodies and occasionally over secondary lysosomes, in addition to the structures mentioned above, while at 3 and 6 hours, an increasing number of secondary lysosomes became labeled. At 24 hours, binding of (/sup 125/I)hCG to the microvillar processes of Leydig cells persisted but was diminished, although a few endosomes, multivesicular bodies and secondary lysosomes still showed a radioautographic reaction. No membranous tubules that were seen in close proximity to, or in continuity with, endosomes and multivesicular bodies were observed to be labeled at any time interval.« less

  10. Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds.

    PubMed

    Altschuler, M D; Kassaee, A

    1997-02-01

    To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an 'NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use 'local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good 'global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.

  11. Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds

    NASA Astrophysics Data System (ADS)

    Altschuler, Martin D.; Kassaee, Alireza

    1997-02-01

    To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an `NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use `local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good `global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.

  12. Decreased fractional urinary calcium excretion and serum 1,25-dihydroxyvitamin D and IGF-I levels in preeclampsia.

    PubMed

    Halhali, Ali; Díaz, Lorenza; Avila, Euclides; Ariza, Ana Carolina; Garabédian, Michèle; Larrea, Fernando

    2007-03-01

    During preeclampsia several alterations of calcium metabolism have been described, the most common of them is hypocalciuria, which pathophysiology is still unclear. In order to assess the contribution of calciotropic hormones to urinary calcium excretion, a cross-sectional study was done including 26 preeclamptic Mexican women (PE group) and 26 normotensive control pregnant women (NT group). Total and fractional urinary calcium excretion were significantly lower (P<0.0001) in the PE group than in the NT group (82+/-7 versus 171+/-7 mg/24h and 0.62+/-0.38 versus 1.38+/-0.71%, respectively), without significant differences in creatinine clearance, urinary sodium excretion and phosphate tubular reabsorption. In addition, serum 1,25-(OH)(2)D and IGF-I levels were significantly (P<0.05) lower in the PE than in NT group (43+/-9 versus 50+/-9 pg/mL and 195+/-67 versus 293+/-105 ng/mL, respectively), without significant differences in serum PTH levels. In the NT group, association analysis showed that total and fractional urinary calcium excretions positively correlated with serum levels of 1,25-(OH)(2)D (P<0.01) and IGF-I (P<0.001). In the PE group, total urinary calcium excretion positively correlated only with serum 1,25-(OH)(2)D (P<0.05). In conclusion, the results obtained in this study confirm that PE is associated with hypocalciuria and suggest that 1,25-(OH)(2)D and/or IGF-I may be involved in the regulation of urinary calcium excretion.

  13. 40 CFR 125.98 - As the Director, what must I do to comply with the requirements of this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false As the Director, what must I do to comply with the requirements of this subpart? 125.98 Section 125.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Requirements...

  14. 40 CFR 125.89 - As the Director, what must I do to comply with the requirements of this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false As the Director, what must I do to comply with the requirements of this subpart? 125.89 Section 125.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Requirements...

  15. Synaptosomal binding of 125I-labelled daboiatoxin, a new PLA2 neurotoxin from the venom of Daboia russelli siamensis.

    PubMed

    Maung-Maung-Thwin; Gopalakrishnakone, P; Yuen, R; Tan, C H

    1996-02-01

    Daboiatoxin (DbTx), the PLA2 neurotoxin from Daboia russelli siamensis venom, was shown to bind specifically and saturably to rat cerebrocortical synaptosomes and synaptic membrane fragments. Two families of binding sites were detected by equilibrium binding analysis in the presence and absence of Ca2+. Scatchard analysis of biphasic plateaus revealed Kdl 5 nM and Bmax1, 6 pmoles/mg protein, and Kd2 80 nM and Bmax2 20 pmoles/mg protein, respectively, for the high- and low-affinity binding sites. The binding of 125I-DbTx to synaptosomes did not show marked dependence on Ca2+, Mg2+, Co2+ and Sr2+. Native DbTx was the only strong competitor to 125I-DbTx synaptosomal binding (IC50 12.5 nM, KI 5.5 nM). Two other crotalid PLA2 neurotoxins, crotoxin CB and mojave toxin basic subunit, and nontoxic C. Atrox PLA2 enzyme, were relatively weaker inhibitors, while two viperid PLA2 neurotoxins, ammodytoxin A and VRV PL V, were very weak inhibitors. Crotoxin CA was a poor inhibitor even at microM concentrations, whereas no inhibitory effect at all was observed with crotoxin CACB, ammodytoxin C, VRV PL VIIIa, taipoxin, beta-bungarotoxin, or with PLA2 enzymes from N. naja venom, E. schistosa venom, bee venom and porcine pancreas. All other pharmacologically active ligands examined (epinephrine, norepinephrine, histamine, choline, dopamine, serotonin, GABA, naloxone, WB-4101, atropine, hexamethonium and alpha-bun-garotoxin) also failed to interfere with 125I-DbTx binding. As those competitors that showed partial inhibition were effective only at microM concentration range compared to the Kd (5 nM) of 125I-DbTx synaptosomal binding, DbTx could well recognize a different neuronal binding site. Rabbit anti-DbTx polyclonal antisera completely blocked the specific binding. When a range of Ca2+ and K+ channels modulators were examined, Ca2+ channel blockers (omega-conotoxins GVIA and MVIIC, taicatoxin, calciseptine and nitrendiprene) did not affect the binding even at high concentrations

  16. Early fixation of cobalt-chromium based alloy surgical implants to bone using a tissue-engineering approach.

    PubMed

    Ogawa, Munehiro; Tohma, Yasuaki; Ohgushi, Hajime; Takakura, Yoshinori; Tanaka, Yasuhito

    2012-01-01

    To establish the methods of demonstrating early fixation of metal implants to bone, one side of a Cobalt-Chromium (CoCr) based alloy implant surface was seeded with rabbit marrow mesenchymal cells and the other side was left unseeded. The mesenchymal cells were further cultured in the presence of ascorbic acid, β-glycerophosphate and dexamethasone, resulting in the appearance of osteoblasts and bone matrix on the implant surface. Thus, we succeeded in generating tissue-engineered bone on one side of the CoCr implant. The CoCr implants were then implanted in rabbit bone defects. Three weeks after the implantation, evaluations of mechanical test, undecalcified histological section and electron microscope analysis were performed. Histological and electron microscope images of the tissue engineered surface exhibited abundant new bone formation. However, newly formed bone tissue was difficult to detect on the side without cell seeding. In the mechanical test, the mean values of pull-out forces were 77.15 N and 44.94 N for the tissue-engineered and non-cell-seeded surfaces, respectively. These findings indicate early bone fixation of the tissue-engineered CoCr surface just three weeks after implantation.

  17. Early Fixation of Cobalt-Chromium Based Alloy Surgical Implants to Bone Using a Tissue-engineering Approach

    PubMed Central

    Ogawa, Munehiro; Tohma, Yasuaki; Ohgushi, Hajime; Takakura, Yoshinori; Tanaka, Yasuhito

    2012-01-01

    To establish the methods of demonstrating early fixation of metal implants to bone, one side of a Cobalt-Chromium (CoCr) based alloy implant surface was seeded with rabbit marrow mesenchymal cells and the other side was left unseeded. The mesenchymal cells were further cultured in the presence of ascorbic acid, β-glycerophosphate and dexamethasone, resulting in the appearance of osteoblasts and bone matrix on the implant surface. Thus, we succeeded in generating tissue-engineered bone on one side of the CoCr implant. The CoCr implants were then implanted in rabbit bone defects. Three weeks after the implantation, evaluations of mechanical test, undecalcified histological section and electron microscope analysis were performed. Histological and electron microscope images of the tissue engineered surface exhibited abundant new bone formation. However, newly formed bone tissue was difficult to detect on the side without cell seeding. In the mechanical test, the mean values of pull-out forces were 77.15 N and 44.94 N for the tissue-engineered and non-cell-seeded surfaces, respectively. These findings indicate early bone fixation of the tissue-engineered CoCr surface just three weeks after implantation. PMID:22754313

  18. Distribution in Rats Internal Organs of Intraperitoneally Given 125I-Labeled Heptapeptide [2-8]-Leucopyrokinin ([2-8]-LPK), a Truncated Analog of Insect Neuropeptide Leucopyrokinin.

    PubMed

    Ryszka, Florian; Dolińska, Barbara; Suszka-Świtek, Aleksandra; Rykaczewska-Czerwińska, Monika; Konopińska, Danuta; Kuczer, Mariola; Plech, Andrzej

    2015-01-01

    It was previously found that synthetic, insect-derived octapeptide leucopyrokinin (LPK) applied directly into the lateral brain ventricle induced a significant antinociceptive effect in rats. Its synthetic truncated analog heptapeptide [2-8]-leucopyrokinin displayed a stronger antinociceptive effect in comparison to native LPK. Moreover it was previously found a high accumulation of these both 125I-labeled peptides in adrenals, as well as in hypothalamus and in hippocampus of rats brain. The aim of the present study was to assess the distribution of 125I-labeled [2-8]-leucopyrokinin in rats' internal organs an in several parts of the brain after peripheral - intraperitoneal (i.p.) administration. The study was performed on male Wistar rats. A synthetic [2-8]-leucopyrokinin ([2-8]-LPK) was iodinated with Na125I. On the day of experiment a solution of 125I-[2-8]-LPK was i.p. injected and the next after 1 and 24 h animals were sacrificed by decapitation. Radioactivity levels in samples of parts of the brain and of internal organs were determined by counter Gamma Auto Count. A uniform, low accumulation 125I-[2-8]-LPK was found in evaluated samples of the brain and in internal organs. The results of the present study indicate a weak penetration into the brain and internal organs of intraperitoneally applied 125I-[2-8]-LPK in rats and correspond with previously determined weak biological effects of i.p. injected LPK and [2-8]-LPK.

  19. 40 CFR 125.82 - When must I comply with this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...? 125.82 Section 125.82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Requirements Applicable to Cooling Water Intake Structures for New Facilities Under Section 316(b) of the Act § 125.82...

  20. 40 CFR 125.82 - When must I comply with this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? 125.82 Section 125.82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS CRITERIA AND STANDARDS FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Requirements Applicable to Cooling Water Intake Structures for New Facilities Under Section 316(b) of the Act § 125.82...

  1. Effect of pollen load size and source (self, outcross) on seed and fruit production in highbush blueberry cv. 'Bluecrop' (VACCINIUM CORYMBOSUM; Ericaceae).

    PubMed

    Dogterom, M H; Winston, M L; Mukai, A

    2000-11-01

    Reproductive fitness of a plant is ultimately determined by both number and quality of seed offspring. This is determined by sexual selection of pollen microspores and ovules during pollination and fertilization. These processes may include pollen competition and seed abortion, which reduce the number of microspores and ovules available for final seed production. Thus, even an excess of pollen microspores to ovules does not result in fertile seeds equal to ovule number. We investigated pollen requirements of highbush blueberry (Vaccinium corymbosum cultivar 'Bluecrop') for maximal seed production and how fertile seed number translates into fruit quality, since fruit quality would ultimately determine the dispersal of its offspring. We demonstrate that individual blueberry flowers with a mean of 106 ovules reach their maximum fruit set and mass and minimum time to ripen when 125 outcross pollen tetrads pollinate a flower, compared to 10 or 25. Three hundred tetrads resulted in the increase of fertile seeds, but did not result in a further increase of fruit mass or fruit set, or decrease in time to ripen. We also examined the effect of pure and mixed loads of self and outcross pollen (25 and 125 tetrads), and found no differences in fertile seed number, fruit mass, or percentage fruit set when pollen loads were either 25 self or outcross pollen tetrads, although number of days to ripen was significantly shorter by 8 d with 25 outcross tetrads. When the pollen load of 125 tetrads consisted of self or a 50:50 mixture of self and outcross pollen, fruit mass, days to ripen, and percentage fruit set were not different from loads of 125 outcross pollen. In addition, a pollen load of 25 outcross tetrads resulted in fertile seed number and fruit quality in between that of 25 self, and 125 self, 125 mixed, or 125 outcross tetrads. Large, small, and flat seed types were identified, and only large seeds (length = 1.7 mm) were fertile. These results improve our understanding of

  2. Biomechanical behavior of 2-implant-and single-implant-retained mandibular overdentures with conventional or mini implants.

    PubMed

    Pisani, Marina Xavier; Presotto, Anna Gabriella Camacho; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo; Kemmoku, Daniel Takanori; Del Bel Cury, Altair Antoninha

    2018-04-24

    The use of single or mini dental implants to retain mandibular overdentures is still questionable. The purpose of this finite element analysis (FEA) study was to investigate the biomechanical behavior of 2- and single-implant-retained mandibular overdentures with conventional or mini implants. Four 3-dimensional (3D) finite element models were constructed with the following designs of mandibular overdentures: 2 (group 2-C) and single (group 1-C) conventional external hexagon implants with ball or O-ring attachment and 2 (group 2-M) and single (group 1-M) 1-piece mini implants. A 150-N axial load was applied bilaterally and simultaneously on the first molar. Overdenture displacement, von Mises equivalent stress (implants and/or prosthetic components), and maximum principal stresses (peri-implant bone) were recorded numerically and then color-coded and compared among the groups. The overdenture displacement (in mm) was higher for the 1-M (0.16) and 2-M (0.17) groups when compared with 1-C (0.09) and 2-C (0.08). Irrespective of the type of implant, the single-implant groups presented higher values of stress (in MPa) on the implants than did the 2-implant groups (1-C=52.53; 1-M=2.95; 2-C=34.66; 2-M=2.37), ball attachment (1-C=201.33; 2-C=159.06), housing or O-ring (1-C=125.01; 1-M=1.96; 2-C=88.84; 2-M=1.27), and peri-implant cortical bone (1-C=19.37; 1-M=1.47; 2-C=15.70; 2-M=1.06). The mini implant overdentures presented lower stress values on the implants, housing or O-ring, and peri-implant bone than did the conventional implant overdentures, regardless of the number of implants. The 2-implant-retained overdentures exhibited lower stresses than the single- implant-retained overdentures, irrespective of the type of implant. The mini implants demonstrated higher overdenture displacement and lower stresses than did conventional implant overdentures for single- and 2-implant-retained overdentures. Copyright © 2018 Editorial Council for the Journal of Prosthetic

  3. Dosimetric comparison between model 9011 and 6711 sources in prostate implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hualin, E-mail: zhang248@iupui.edu; Arizona Oncology Services, Phoenix, AZ; Beyer, David

    2013-07-01

    The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by sidemore » in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.« less

  4. Intraoperative Localisation of Impalpable Breast Lesions Utilising the ROLLIS Technique Following Peritumoral 99mTc-colloid Sentinel Node Lymphoscintigraphy.

    PubMed

    Hung, Te-Jui; Burrage, John; Bourke, Anita; Taylor, Donna

    2017-08-24

    Ultrasound or stereotactic guided hook-wire localisation has been the standard-of-care for the pre-surgical localisation of impalpable breast lesions, which account for approximately a third of all breast cancer. Radioguided occult lesion localisation using I-125 seeds (ROLLIS) is a relatively new technique for guiding surgical excision of impalpable breast lesions, and is a promising alternative to the traditional hook-wire method. When combined with Tc-99m labelled colloid for sentinel node mapping in clinically indicated cases, there has been uncertainty regarding whether the downscatter of Tc-99m into the I-125 energy spectrum could adversely affect the intra-operative detection of the I-125 seed, especially pertaining to a peritumoral injection. To evaluate the percentage contribution of downscattered activity from Tc-99m into the I-125 energy spectrum in simulated intra-operative resections of an I-125 seed following different sentinel node injection techniques. Two scenarios were simulated using breast phantoms with lean chicken breast. The first scenario, with a 2cm distance between the Tc-99m injection site and the I-125 seed, simulated a periareolar ipsiquadrant injection with the subdermal or intradermal technique. The second scenario simulated a peritumoral injection technique with the Tc-99m bolus and an I-125 seed at the same site. Count rates were acquired with a hand-held gamma probe, and the percentage contribution of downscattered Tc-99m gamma photons to the I-125 energy window was calculated. In scenarios one and two, downscattered Tc-99m activity contributed 0.5% and 33% respectively to the detected count rate in the I-125 energy window. In both scenarios, the I-125 seed was successfully localised and removed using the gamma probe. There is no significant contribution of downscattered activity associated with a peritumoral injection of Tc-99m to adversely affect the accurate intra-operative localisation of an I- 125 seed. Copyright© Bentham

  5. Comparison of the ANSI, RSD, KKH, and BRMD thyroid-neck phantoms for 125I thyroid monitoring.

    PubMed

    Kramer, G H; Olender, G; Vlahovich, S; Hauck, B M; Meyerhof, D P

    1996-03-01

    The Human Monitoring Laboratory, which acts as the Canadian National Calibration Reference Centre for In Vivo Monitoring, has determined the performance characteristics of four thyroid phantoms for 125I thyroid monitoring. The phantoms were a phantom built to the specifications of the American National Standards Institute Standard N44.3; the phantom available from Radiology Support Devices; the phantom available from Kyoto Kagaku Hyohon; the phantom manufactured by the Human Monitoring Laboratory and known as the BRMD phantom. The counting efficiencies of the phantoms for 125I were measured at different phantom-to-detector distances. The anthropomorphic characteristics of the phantoms have been compared with the average man parameters. It was concluded that the BRMD, American National Standards Institute, and Radiology Support Devices phantoms have the same performance characteristics when the neck-to-detector distances are greater than 12 cm and all phantoms are essentially equivalent at 30 cm or more. The Kyoto Kagaku Hyohon phantom showed lower counting efficiencies at phantom-to-detector distances less than 30 cm. This was attributed to the design of the phantom. This study has also shown that the phantom need not be highly anthropomorphic provided the calibration is not performed at short neck-detector distances. Indeed, it might be possible to use t simple point source of 125I placed behind a 1.5 cm block of lucite at neck detector distances of 12 cm or more.

  6. Development of self-anchoring bone implants. I. Processing and material characterization.

    PubMed

    Abusafieh, A; Siegler, S; Kalidindi, S R

    1997-01-01

    We recently designed and produced a family of new swelling-type materials that are potentially capable of self-fixation in bone. These materials are designed to absorb body fluids and swell by small amounts, which will allow the implants made from these materials to achieve self-fixation by an expansion-fit mechanism. The developed material system is essentially a crosslinked random copolymer based on poly (methyl methacrylate-acrylic acid). For potential structural (load-bearing) bioimplant applications, we reinforced this copolymer with AS-4 carbon and Kevlar 49 fibers. The details of processing these materials and the steps involved in optimizing their microstructures are presented in this article. A set of mechanical tests were performed on these materials in both dry and swollen conditions to measure their moduli and yield strengths. In the dry state, the copolymers were found to exhibit Young's moduli in the range of 3 to 4 GPa and yield strengths in the range of 70 to 85 MPa. The reinforced composites exhibited moduli in the range of 15 to 65 GPa and yield strengths in the range of 125 to 500 MPa. Upon controlling the volumetric swelling in these materials to be less than about 10%, the loss in mechanical properties was found to be less than about 30%. These hygromechanical properties are well suited for self-anchoring bone implant applications.

  7. Dose escalation in permanent brachytherapy for prostate cancer: dosimetric and biological considerations

    NASA Astrophysics Data System (ADS)

    Li, X. Allen; Wang, Jian Z.; Stewart, Robert D.; Di Biase, Steven J.

    2003-09-01

    No prospective dose escalation study for prostate brachytherapy (PB) with permanent implants has been reported. In this work, we have performed a dosimetric and biological analysis to explore the implications of dose escalation in PB using 125I and 103Pd implants. The concept of equivalent uniform dose (EUD), proposed originally for external-beam radiotherapy (EBRT), is applied to low dose rate brachytherapy. For a given 125I or 103Pd PB, the EUD for tumour that corresponds to a dose distribution delivered by EBRT is calculated based on the linear quadratic model. The EUD calculation is based on the dose volume histogram (DVH) obtained retrospectively from representative actual patient data. Tumour control probabilities (TCPs) are also determined in order to compare the relative effectiveness of different dose levels. The EUD for normal tissue is computed using the Lyman model. A commercial inverse treatment planning algorithm is used to investigate the feasibility of escalating the dose to prostate with acceptable dose increases in the rectum and urethra. The dosimetric calculation is performed for five representative patients with different prostate sizes. A series of PB dose levels are considered for each patient using 125I and 103Pd seeds. It is found that the PB prescribed doses (minimum peripheral dose) that give an equivalent EBRT dose of 64.8, 70.2, 75.6 and 81 Gy with a fraction size of 1.8 Gy are 129, 139, 150 and 161 Gy for 125I and 103, 112, 122 and 132 Gy for 103Pd implants, respectively. Estimates of the EUD and TCP for a series of possible prescribed dose levels (e.g., 145, 160, 170 and 180 Gy for 125I and 125, 135, 145 and 155 for 103Pd implants) are tabulated. The EUD calculation was found to depend strongly on DVHs and radiobiological parameters. The dosimetric calculations suggest that the dose to prostate can be escalated without a substantial increase in both rectal and urethral dose. For example, increasing the PB prescribed dose from 145 to

  8. Implantation of programmable infusion pumps for insulin delivery in type I diabetic patients.

    PubMed

    Walter, H; Günther, A; Kronski, D; Flaschenträger, T; Mehnert, H

    1989-06-01

    Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.

  9. Auger-electron cascades, charge potential and microdosimetry of iodine-125.

    PubMed

    Booz, J; Paretzke, H G; Pomplun, E; Olko, P

    1987-01-01

    This paper is a contribution to the microdosimetry of I-125. It shows microdosimetric spectra of individual and average disintegrations of I-125 for various target sizes and gives evidence for the relative contributions of energy-deposition events of low and high LET. It further presents information on the relative efficiencies of Auger-electrons and multiple charges in terms of local energy deposition, e.g. to model targets of DNA, and discusses their radiobiological implications, e.g. the microdosimetric understanding of the different efficiencies of specific and random incorporations of I-125. When I-125 is specifically incorporated into DNA, most of the energy deposition events are very large, e.g. above 40 keV/micron for a simulated target volume of 20 nm diameter, regardless of the number and energy of Auger electrons emitted. Therefore it is not necessary, for the discussion of the radiobiological implications, to distinguish between different classes of disintegrations. For unspecific, homogeneous incorporation of I-125 somewhere into tissue, about 20% of the dose to critical targets of 25 nm diameter is made up by disintegrations that happen to occur within these targets. When assuming that other critical targets and target structures can be neglected, this part of the dose will be equally effective as in the case of specific incorporation of I-125 into such target models. In addition, there are the normal, low-LET radiation effects from the other, 80% large fraction of the dose. With this information, for the biological systems and end points for which a short section of the elemental chromatine fiber can be taken as the relevant critical target, it is shown that the expected D37 value for homogeneous unspecific incorporation of I-125 can be estimated when the D37 for specific incorporation in DNA is known. For an example calculation, the estimated D37-value for nonspecific, homogeneous incorporation of I-125 would be about half as effective as

  10. Determination and analysis of site-specific 125I decay-induced DNA double-strand break end-group structures.

    PubMed

    Datta, Kamal; Weinfeld, Michael; Neumann, Ronald D; Winters, Thomas A

    2007-02-01

    End groups contribute to the structural complexity of radiation-induced DNA double-strand breaks (DSBs). As such, end-group structures may affect a cell's ability to repair DSBs. The 3'-end groups of strand breaks caused by gamma radiation, or oxidative processes, under oxygenated aqueous conditions have been shown to be distributed primarily between 3'-phosphoglycolate and 3'-phosphate, with 5'-phosphate ends in both cases. In this study, end groups of the high-LET-like DSBs caused by 125I decay were investigated. Site-specific DNA double-strand breaks were produced in plasmid pTC27 in the presence or absence of 2 M DMSO by 125I-labeled triplex-forming oligonucleotide targeting. End-group structure was assessed enzymatically as a function of the DSB end to serve as a substrate for ligation and various forms of end labeling. Using this approach, we have demonstrated 3'-hydroxyl (3'-OH) and 3'-phosphate (3'-P) end groups and 5'-ends (> or = 42%) terminated by phosphate. A 32P postlabeling assay failed to detect 3'-phosphoglycolate in a restriction fragment terminated by the 125I-induced DNA double-strand break, and this is likely due to restricted oxygen diffusion during irradiation as a frozen aqueous solution. Even so, end-group structure and relative distribution varied as a function of the free radical scavenging capacity of the irradiation buffer.

  11. WE-AB-BRA-12: Post-Implant Dosimetry in Prostate Brachytherapy by X-Ray and MRI Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S; Song, D; Lee, J

    Purpose: For post-implant dosimetric assessment after prostate brachytherapy, CT-MR fusion approach has been advocated due to the superior accuracy on both seeds localization and soft tissue delineation. However, CT deposits additional radiation to the patient, and seed identification in CT requires manual review and correction. In this study, we propose an accurate, low-dose, and cost-effective post-implant dosimetry approach based on X-ray and MRI. Methods: Implanted seeds are reconstructed using only three X-ray fluoroscopy images by solving a combinatorial optimization problem. The reconstructed seeds are then registered to MR images using an intensity-based points-to-volume registration. MR images are first pre-processed bymore » geometric and Gaussian filtering, yielding smooth candidate seed-only images. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine followed by local deformable registrations. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. Results: We tested our algorithm on twenty patient data sets. For quantitative evaluation, we obtained ground truth seed positions by fusing the post-implant CT-MR images. Seeds were semi-automatically extracted from CT and manually corrected and then registered to the MR images. Target registration error (TRE) was computed by measuring the Euclidean distances from the ground truth to the closest registered X-ray seeds. The overall TREs (mean±standard deviation in mm) are 1.6±1.1 (affine) and 1.3±0.8 (affine+deformable). The overall computation takes less than 1 minute. Conclusion: It has been reported that the CT-based seed localization error is ∼1.6mm and the seed localization uncertainty of 2mm results in less than 5% deviation of

  12. An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect.

    PubMed

    Abboud, F; Scalliet, P; Vynckier, S

    2008-12-01

    Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast implant, similar to that used in the treatment of prostate cancer, has been proposed by [N. Jansen et al., Int. J. Radiat. Oncol. Biol. Phys. 67, 1052-1058 (2007)] with encouraging results. The presence of artifacts from the metallic seeds, however, can disturb follow-up imaging. The development of plastic seeds has reduced these artifacts. This paper presents a feasibility study of the advantages of palladium-103 seeds, encapsulated with a biocompatible polymer, for future clinical applications, and on the effect of the gold marker on the dosimetric characteristics of such seeds. Experimental palladium seeds, OptiSeedexp, were manufactured by International Brachytherapy (IBt), Seneffe, Belgium, from a biocompatible polymer, including the marker. Apart from the absence of a gold marker, the studied seed has an identical design to the OptiSeed103 [Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)]. Polymer encapsulation was preferred by IBt in order to reduce the quantity of radioactive material needed for a given dose rate and to reduce the anisotropy of the radiation field around the seed. In addition, this design is intended to decrease the interseed effects that can occur as a result of the marker and the encapsulation. Dosimetric measurements were performed using LiF thermoluminescent dosimeters (1 mm3) in solid water phantoms (WT1). Measured data were compared to Monte Carlo simulated data in solid water using the MCNP code, version 4C. Updated cross sections [Med. Phys. 30, 701-711 (2003)] were used. As the measured and calculated data were in agreement, Monte Carlo calculations were then performed in liquid water to

  13. SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narayana, V; McLaughlin, P; University of Michigan, Ann Arbor, MI

    Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mmmore » expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.« less

  14. Impact of the newly arrived seed-predating beetle Specularius impressithorax (Coleoptera: Chrysomelidae: Bruchinae) in Hawai'i

    USGS Publications Warehouse

    Medeiros, A.C.; Von Allmen, E.; Fukada, M.; Samuelson, A.; Lau, T.

    2008-01-01

    Prior to 2001, seed predation was virtually absent in the endemic Wiliwili Erythrina sandwicensis (Fabaceae: Degener), dominant tree species of lower-elevation Hawaiian dryland forests. The African bruchine chrysomelid Specularius impressithorax (Pic) (Coleoptera: Chrysomelidae: Bruchinae) was first detected in Hawai'i in 2001 and became established on all main islands within the next two years. The mode of entry for this invasive Erythrina seed predator into Hawai'i is unknown, but likely occurred with the importation of trinket jewelry from Africa containing characteristically brightly-colored Erythrina seeds. The initial establishment of this insect likely occurred on a non-native host, the widely cultivated coral tree E. variegata. Within three years of its first record, S. impressithorax accounted for 77.4% mean seed crop loss in 12 populations of Wiliwili on six main Hawaiian islands. Specularius impressithorax, dispersed through international commerce and established via E. variegata, has become a threat to a unique Hawaiian forest type and may threaten other Erythrina, especially New World representatives.

  15. Dose reduction in LDR brachytherapy by implanted prostate gold fiducial markers.

    PubMed

    Landry, Guillaume; Reniers, Brigitte; Lutgens, Ludy; Murrer, Lars; Afsharpour, Hossein; de Haas-Kock, Danielle; Visser, Peter; van Gils, Francis; Verhaegen, Frank

    2012-03-01

    The dosimetric impact of gold fiducial markers (FM) implanted prior to external beam radiotherapy of prostate cancer on low dose rate (LDR) brachytherapy seed implants performed in the context of combined therapy was investigated. A virtual water phantom was designed containing a single FM. Single and multi source scenarios were investigated by performing Monte Carlo dose calculations, along with the influence of varying orientation and distance of the FM with respect to the sources. Three prostate cancer patients treated with LDR brachytherapy for a recurrence following external beam radiotherapy with implanted FM were studied as surrogate cases to combined therapy. FM and brachytherapy seeds were identified on post implant CT scans and Monte Carlo dose calculations were performed with and without FM. The dosimetric impact of the FM was evaluated by quantifying the amplitude of dose shadows and the volume of cold spots. D(90) was reported based on the post implant CT prostate contour. Large shadows are observed in the single source-FM scenarios. As expected from geometric considerations, the shadows are dependent on source-FM distance and orientation. Large dose reductions are observed at the distal side of FM, while at the proximal side a dose enhancement is observed. In multisource scenarios, the importance of shadows appears mitigated, although FM at the periphery of the seed distribution caused underdosage (seed implant dose distributions. Therefore, reduced tumor control could be expected from FM implanted in tumors, although our results are too limited to draw conclusions

  16. The study of two barley Type I-like MADS-box genes as potential targets of epigenetic regulation during seed development

    PubMed Central

    2012-01-01

    Background MADS-box genes constitute a large family of transcription factors functioning as key regulators of many processes during plant vegetative and reproductive development. Type II MADS-box genes have been intensively investigated and are mostly involved in vegetative and flowering development. A growing number of studies of Type I MADS-box genes in Arabidopsis, have assigned crucial roles for these genes in gamete and seed development and have demonstrated that a number of Type I MADS-box genes are epigenetically regulated by DNA methylation and histone modifications. However, reports on agronomically important cereals such as barley and wheat are scarce. Results Here we report the identification and characterization of two Type I-like MADS-box genes, from barley (Hordeum vulgare), a monocot cereal crop of high agronomic importance. Protein sequence and phylogenetic analysis showed that the putative proteins are related to Type I MADS-box proteins, and classified them in a distinct cereal clade. Significant differences in gene expression among seed developmental stages and between barley cultivars with varying seed size were revealed for both genes. One of these genes was shown to be induced by the seed development- and stress-related hormones ABA and JA whereas in situ hybridizations localized the other gene to specific endosperm sub-compartments. The genomic organization of the latter has high conservation with the cereal Type I-like MADS-box homologues and the chromosomal position of both genes is close to markers associated with seed quality traits. DNA methylation differences are present in the upstream and downstream regulatory regions of the barley Type I-like MADS-box genes in two different developmental stages and in response to ABA treatment which may be associated with gene expression differences. Conclusions Two barley MADS-box genes were studied that are related to Type I MADS-box genes. Differential expression in different seed developmental

  17. Measurement of the intensity ratio of Auger and conversion electrons for the electron capture decay of 125I.

    PubMed

    Alotiby, M; Greguric, I; Kibédi, T; Lee, B Q; Roberts, M; Stuchbery, A E; Tee, Pi; Tornyi, T; Vos, M

    2018-03-21

    Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of 125 I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. Our results indicate that for 125 I the calculations based on rates from the Evaluated Atomic Data Library underestimate the K Auger yields by 20%.

  18. Measurement of the intensity ratio of Auger and conversion electrons for the electron capture decay of 125I

    NASA Astrophysics Data System (ADS)

    Alotiby, M.; Greguric, I.; Kibédi, T.; Lee, B. Q.; Roberts, M.; Stuchbery, A. E.; Tee, Pi; Tornyi, T.; Vos, M.

    2018-03-01

    Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of 125I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. Our results indicate that for 125I the calculations based on rates from the Evaluated Atomic Data Library underestimate the K Auger yields by 20%.

  19. iPad2(R) use in patients with implantable cardioverter defibrillators causes electromagnetic interference: the EMIT Study.

    PubMed

    Kozik, Teri M; Chien, Gianna; Connolly, Therese F; Grewal, Gurinder S; Liang, David; Chien, Walter

    2014-04-10

    Over 140 million iPads(®) have been sold worldwide. The iPad2(®), with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life-threatening situations in patients. The goal of this study was to determine whether the iPad2(®) can cause electromagnetic interference in patients with implantable cardioverter defibrillators. Twenty-seven patients with implantable cardioverter defibrillators were studied. The iPad2(®) was held at reading distance and placed directly over the device with cellular data capability activated and deactivated. The manufacturers/models of devices and the patients' body mass index were noted. The presence of electromagnetic interference was detected by using a programmer supplied by each manufacturer. Magnet mode with suspension of anti-tachycardia therapy was triggered in 9 (33%) patients. All occurred when the iPad2(®) was placed directly over the device. The cellular data status did not cause interference and no noise or oversensing was noted. There was no significant difference between the mean body mass index of the groups with or without interference. The iPad2(®) can trigger magnet mode in implantable cardioverter defibrillators when laid directly over the device. This is potentially dangerous if patients should develop life-threatening arrhythmias at the same time. As new electronic products that use magnets are produced, the potential risk to patients with implantable defibrillators needs to be addressed.

  20. Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds.

    PubMed

    Torres Del Río, J; Tornero-López, A M; Guirado, D; Pérez-Calatayud, J; Lallena, A M

    2017-06-01

    To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. The effect of overestimation observed in the chamber responses once they are corrected for the standard pressure and temperature may represent a non-negligible ∼4% overestimation in high altitude cities as ours (700m AMSL). This overestimation behaves linearly with the air density in all cases analyzed. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Automated seed localization from CT datasets of the prostate.

    PubMed

    Brinkmann, D H; Kline, R W

    1998-09-01

    With the increasing utilization of permanent brachytherapy implants for treating carcinoma of the prostate, the importance of accurate post-treatment dose calculation also increases for assessing patient outcome and planning future treatments. An automatic method for seed localization of permanent brachytherapy implants, using CT datasets of the prostate, has been developed and tested on a phantom using an actual patient planned seed distribution. This method was also compared to results with the three-film technique for three patient datasets. The automatic method is as accurate or more accurate than the three film technique for 1 mm, 3 mm, and 5 mm contiguous CT slices, and eliminates the inter- and intra-observer variability of the manual methods. The automated method improves the localization of brachytherapy seeds while reducing the time required for the user to input information, and is demonstrated to be less operator dependent, less time consuming, and potentially more accurate than the three-film technique.

  2. A Monte Carlo study of I-125 prostate brachytherapy with gold nanoparticles: dose enhancement with simultaneous rectal dose sparing via radiation shielding.

    PubMed

    Brivio, D; Nguyen, P L; Sajo, E; Ngwa, W; Zygmanski, P

    2017-03-07

    We investigate via Monte Carlo simulations a new 125 I brachytherapy treatment technique for high-risk prostate cancer patients via injection of Au nanoparticle (AuNP) directly into the prostate. The purpose of using the nanoparticles is to increase the therapeutic index via two synergistic effects: enhanced energy deposition within the prostate and simultaneous shielding of organs at risk from radiation escaping from the prostate. Both uniform and non-uniform concentrations of AuNP are studied. The latter are modeled considering the possibility of AuNP diffusion after the injection using brachy needles. We study two extreme cases of coaxial AuNP concentrations: centered on brachy needles and centered half-way between them. Assuming uniform distribution of 30 mg g -1 of AuNP within the prostate, we obtain a dose enhancement larger than a factor of 2 to the prostate. Non-uniform concentration of AuNP ranging from 10 mg g -1 and 66 mg g -1 were studied. The higher the concentration in a given region of the prostate the greater is the enhancement therein. We obtain the highest dose enhancement when the brachytherapy needles are coincident with AuNP injection needles but, at the same time, the regions in the tail are colder (average dose ratio of 0.7). The best enhancement uniformity is obtained with the seeds in the tail of the AuNP distribution. In both uniform and non-uniform cases the urethra and rectum receive less than 1/3 dose compared to an analog treatment without AuNP. Remarkably, employing AuNP not only significantly increases dose to the target but also decreases dose to the neighboring rectum and even urethra, which is embedded within the prostate. These are mutually interdependent effects as more enhancement leads to more shielding and vice-versa. Caution must be paid since cold spot or hot spots may be created if the AuNP concentration versus seed position is not properly distributed respect to the seed locations.

  3. A Monte Carlo study of I-125 prostate brachytherapy with gold nanoparticles: dose enhancement with simultaneous rectal dose sparing via radiation shielding

    NASA Astrophysics Data System (ADS)

    Brivio, D.; Nguyen, P. L.; Sajo, E.; Ngwa, W.; Zygmanski, P.

    2017-03-01

    We investigate via Monte Carlo simulations a new 125I brachytherapy treatment technique for high-risk prostate cancer patients via injection of Au nanoparticle (AuNP) directly into the prostate. The purpose of using the nanoparticles is to increase the therapeutic index via two synergistic effects: enhanced energy deposition within the prostate and simultaneous shielding of organs at risk from radiation escaping from the prostate. Both uniform and non-uniform concentrations of AuNP are studied. The latter are modeled considering the possibility of AuNP diffusion after the injection using brachy needles. We study two extreme cases of coaxial AuNP concentrations: centered on brachy needles and centered half-way between them. Assuming uniform distribution of 30 mg g-1 of AuNP within the prostate, we obtain a dose enhancement larger than a factor of 2 to the prostate. Non-uniform concentration of AuNP ranging from 10 mg g-1 and 66 mg g-1 were studied. The higher the concentration in a given region of the prostate the greater is the enhancement therein. We obtain the highest dose enhancement when the brachytherapy needles are coincident with AuNP injection needles but, at the same time, the regions in the tail are colder (average dose ratio of 0.7). The best enhancement uniformity is obtained with the seeds in the tail of the AuNP distribution. In both uniform and non-uniform cases the urethra and rectum receive less than 1/3 dose compared to an analog treatment without AuNP. Remarkably, employing AuNP not only significantly increases dose to the target but also decreases dose to the neighboring rectum and even urethra, which is embedded within the prostate. These are mutually interdependent effects as more enhancement leads to more shielding and vice-versa. Caution must be paid since cold spot or hot spots may be created if the AuNP concentration versus seed position is not properly distributed respect to the seed locations.

  4. TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin

    PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission ratemore » and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.« less

  5. Micro-cutting of silicon implanted with hydrogen and post-implantation thermal treatment

    NASA Astrophysics Data System (ADS)

    Jelenković, Emil V.; To, Suet; Sundaravel, B.; Xiao, Gaobo; Huang, Hu

    2016-07-01

    It was reported that non-amorphizing implantation by hydrogen has a potential in improving silicon machining. Post-implantation high-temperature treatment will affect implantation-induced damage, which can have impact on silicon machining. In this article, a relation of a thermal annealing of hydrogen implanted in silicon to micro-cutting experiment is investigated. Hydrogen ions were implanted into 4″ silicon wafers with 175 keV, 150 keV, 125 keV and doses of 2 × 1016 cm-2, 2 × 1016 cm-2 and 3 × 1016 cm-2, respectively. In this way, low hydrogen atom-low defect concentration was created in the region less than ~0.8 μm deep and high hydrogen atom-high defect concentration was obtained at silicon depth of ~0.8-1.5 μm. The post-implantation annealing was carried out at 300 and 400 °C in nitrogen for 1 h. Physical and electrical properties of implanted and annealed samples were characterized by secondary ion mass spectroscopy (SIMS), X-ray diffraction (XRD), Rutherford backscattering (RBS) and nanoindentation. Plunge cutting experiment was carried out in <110> and <100> silicon crystal direction. The critical depth of cut and cutting force were monitored and found to be influenced by the annealing. The limits of hydrogen implantation annealing contribution to the cutting characteristics of silicon are discussed in light of implantation process and redistribution of hydrogen and defects generation during annealing process.

  6. Deuterium permeation behaviors in tungsten implanted with nitrogen

    NASA Astrophysics Data System (ADS)

    Liang, Chuan-hui; Wang, Dongping; Jin, Wei; Lou, Yuanfu; Wang, Wei; Ye, Xiaoqiu; Chen, Chang-an; Liu, Kezhao; Xu, Haiyan; Wang, Xiaoying; Kleyn, Aart W.

    2018-07-01

    Surface modification of tungsten due to the cooling species nitrogen seeded in the divertor region, i.e., by nitrogen ion implantation or re-deposition, is considered to affect the permeation behavior of H isotopes. This work focuses on the effect of nitrogen ion implantation into tungsten (W-N) on the deuterium gas-driven permeation behavior. For comparison, both permeation in tungsten implanted with W ion (W-W) and without implantation (pristine W) are studied. These three samples were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray photo-electron spectroscopy (XPS). The SEM results revealed that the W-W sample has various voids on the surface, and the W-N sample has a rough surface with pretty fine microstructures. These are different from the pristine W sample with a smooth and compact surface. The XRD patterns show the disappearance of crystallinity on both W-W and W-N sample surfaces. It indicates that the ion implantation process results in an almost complete conversion from crystalline to amorphous in the sample surfaces. The sputter-depth profiling XPS spectra show that the implanted nitrogen prefers to form a 140 nm thick tungsten nitride layer. In permeation experiments, it was found that the D permeability is temperature dependent. Interestingly, the W-N sample presented a lower D permeability than the W-W sample, but higher than the pristine W sample. Such behavior implies that tungsten nitride acts as a permeation barrier, while defects created by ions implantation can promote permeability. The possible permeation mechanism correlated with sample surface composition and microstructure is consequently discussed in this work.

  7. Highly Increased 125I-JR11 Antagonist Binding In Vitro Reveals Novel Indications for sst2 Targeting in Human Cancers.

    PubMed

    Reubi, Jean Claude; Waser, Beatrice; Mäcke, Helmut; Rivier, Jean

    2017-02-01

    There is recent in vitro and in vivo evidence that somatostatin receptor subtype 2 (sst 2 ) antagonists are better tools to target neuroendocrine tumors (NETs) than sst 2 agonists. Indeed, antagonists bind to a greater number of sst 2 sites than agonists. Whether sst 2 antagonists could be used successfully to target non-NETs, expressing low sst 2 density, is unknown. Here, we compare quantitatively 125 I-JR11 sst 2 antagonist binding in vitro with that of the sst 2 agonist 125 I-Tyr 3 -octreotide in large varieties of non-NET and NET. In vitro receptor autoradiography was performed with 125 I-JR11 and 125 I-Tyr 3 -octreotide in cancers from prostate, breast, colon, kidney, thyroid, and lymphoid tissues as well as NETs as reference. In general, 125 I-JR11 binds to many more sst 2 sites than 125 I-Tyr 3 -octreotide. In 13 breast cancers, 8 had a low binding (mean density, 844 ± 168 dpm/mg of tissue) with the agonist whereas 12 had a high binding (mean density, 4,447 ± 1,128 dpm/mg of tissue) with the antagonist. All 12 renal cell cancers showed a low binding of sst 2 with the agonist (mean density, 348 ± 49 dpm/mg of tissue) whereas all cases had a high sst 2 binding with the antagonist (mean density, 3,777 ± 582 dpm/mg of tissue). One of 5 medullary thyroid cancers was positive with the agonist, whereas 5 of 5 were positive with the antagonist. In 15 non-Hodgkin lymphomas, many more sst 2 sites were labeled with the antagonist than with the agonist. In 14 prostate cancers, none had sst 2 binding with the agonist and only 4 had a weak binding with the antagonist. None of 17 colon cancers showed sst 2 sites with the agonist, and only 3 cases were weakly positive with the antagonist. In the various tumor types, adjacent sst 2 -expressing tissues such as vessels, lymphocytes, nerves, mucosa, or stroma were more strongly labeled with the antagonist than with the agonist. The reference NET cases, incubated with a smaller amount of tracer, were also found to have many

  8. Mutagenic and lethal effects of (5-/sup 125/I)lodo-2'-deoxyuridine incorporated into DNA of mammalian cells, and their RBEs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyazaki, N.; Fujiwara, Y.

    1981-12-01

    Decay of /sup 125/I unifilarly incorporated as 5-iodo-2'-deoxyuridine (IdUrd) into DNA of V79 Chinese hamster cells was approximately an order of magnitude more effective in inducing both 6-thioguanine-resistant mutation and cell inactivation than external X rays under equivalent conditions. RBEs of mutation and killing induced by /sup 125/I decays, compared with 170-kVp X rays of low LET, were approx. = 11 for mutation (ratio of the induction rate in frequency/rad = 11.3 X 10/sup -7/ (/sup 125/I)/100 X 10/sup -7/ (X rays at -79/sup o/C)) and approx. = 10 for cell inactivation (D/sub 0/ ratio = 505 rad (X raysmore » at -79/sup o/C)/52 rad (/sup 125/I)). These RBE values may well exceed the reported maximum values for high-LET radiation in the LET range of 80-110 keV/..mu..m, suggesting that the Auger effect is different from the high-LET radiation effect alone. Thus these biological consequences arise not only from radiation effects of Auger electrons on the immediate vicinity in DNA, but also from the nonionogenic effect through charge transfer processes. In addition, higher inductions of mutation and killing by external X rays in unifilarly IdUrd-substituted cells than in ordinal cells were observed, suggesting a possible involvement of X-ray-induced Auger phenomenon in iodine in DNA.« less

  9. Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program.

    PubMed

    Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco

    Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce

  10. Tritiated-nicotine- and /sup 125/I-alpha-bungarotoxin-labeled nicotinic receptors in the interpeduncular nucleus of rats. II. Effects of habenular destruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clarke, P.B.; Hamill, G.S.; Nadi, N.S.

    1986-09-15

    The cholinergic innervation of the interpeduncular nucleus (IPN) is wholly extrinsic and is greatly attenuated by bilateral habenular destruction. We describe changes in the labeling of putative nicotinic receptors within this nucleus at 3, 5, or 11 days after bilateral habenular lesions. Adjacent tissue sections of the rat IPN were utilized for /sup 3/H-nicotine and /sup 125/I-alpha-bungarotoxin (/sup 125/I-BTX) receptor autoradiography. Compared to sham-operated controls, habenular destruction significantly reduced autoradiographic /sup 3/H-nicotine labeling in rostral (-25%), intermediate (-13%), and lateral subnuclei (-36%). Labeling in the central subnucleus was unchanged. Loss of labeling was maximal at the shortest survival time (3more » days) and did not change thereafter. In order to establish whether this loss was due to a reduction in the number or the affinity of /sup 3/H-nicotine-binding sites, a membrane assay was performed on microdissected IPN tissue from rats that had received surgery 3 days previously. Bilateral habenular lesions produced a 35% reduction of high-affinity /sup 3/H-nicotine-binding sites, with no change in binding affinity. Bilateral habenular lesions reduced /sup 125/I-BTX labeling in the intermediate subnuclei, and a slight increase occurred in the rostral subnucleus. In the lateral subnuclei, /sup 125/I-BTX labeling was significantly reduced (27%) at 3 days but not at later survival times. In view of the known synaptic morphology of the habenulointerpeduncular tract, it is concluded that a subpopulation of /sup 3/H-nicotine binding sites within the IPN is located on afferent axons and/or terminals. This subpopulation, located within rostral, intermediate, and lateral subnuclei, may correspond to presynaptic nicotinic cholinergic receptors. Sites that bind /sup 125/I-BTX may include a presynaptic subpopulation located in the lateral and possibly the intermediate subnuclei.« less

  11. Simple, rapid /sup 125/I-labeled cyclosporine double antibody/polyethylene glycol radioimmunoassay used in a pediatric cardiac transplant program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berk, L.S.; Webb, G.; Imperio, N.C.

    1986-01-01

    We modified the Sandoz cyclosporine radioimmunoassay because of our need for frequent clinical monitoring of cyclosporine drug levels in allo- and xenograft pediatric cardiac transplant patients. With application of a commercially available (/sup 125/I)cyclosporine label in place of (/sup 3/H)cyclosporine and a second antibody/polyethylene glycol (PEG) method of separation in place of charcoal separation, we simplified and enhanced the speed and precision of assay performance. Studies of 140 whole blood samples comparing this new method to the (/sup 3/H)cyclosporine radioimmunoassay (RIA) method of Berk and colleagues yielded a coefficient of correlation of 0.96 (p less than 0.00001) with means ofmore » 626 and 667 ng/ml for (/sup 3/H)RIA and (/sup 125/I)RIA, respectively, and a regression equation of y = 28 + 1.02x. The major advantages are that total assay time is reduced to approximately 1 h; (/sup 125/I)cyclosporine label is used, avoiding the problems associated with liquid scintillation counting; and precision is enhanced by separating bound and free fractions with second antibody/PEG. These modifications should provide for greater ease of assay performance and improved clinical utility of cyclosporine monitoring not only in the pediatric but also in the adult transplant patient.« less

  12. SU-E-T-338: Ultrastable PRNA 3WJ Nanoparticles as Potential I-125 and C-131 Carriers for Targeted Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, W; Li, H; Guo, P

    2014-06-01

    Purpose: To study the feasibility of using the pRNA 3WJ nanoparticles to carry I-125 or Cs-131 to target and treat cancer. As the first step, we investigated the stabilities of pRNA 3WJ nanoparticles that are essential for cancer targeting and treatment in this study. Methods: The thermodynamic stability of assembled RNA 3WJ nanoparticles was studied using the TGGE system. The nanoparticles were irradiated with I-125 or Cs-131 radioactive sources that were immersed in the RNA nanoparticle/DNA structure sample liquid contained in a small vial. The irradiation of the RNA samples was performed for different time periods and doses. The purposemore » was to distinguish the effects of radiation on DNA and RNA structures. Unradiated samples were used as control. Results: RNA nanoparticles were formed by mixing three pieces of oligos, 3WJa, 3WJb, and 3WJc at 1:1:1 molar ratio. Figure 4 demonstrates that 2′-F modified 3WJ nanoparticles remained stable at temperatures as high as 66.8 ± 2°C, and exhibited melting temperatures of 71 ± 2°C. The radiation stability test was performed with I- 125 and Cs-131 irradiation. Several DNA structures including plasmids were included as control. The first test introduced I-125 and a low dose of 1 Gy to both RNA and DNA samples, but no change was observed. When the dose was increased to 30 Gy, DNA was damaged while RNA remained unchanged. Three tests were also conducted with Cs-131 with 7 Gy, 21 Gy, 30 Gy, and 89 Gy, and the results were similar to those with I-125. Conclusion: pRNA 3WJ nanoparticles are able to form efficiently by onepot self-assembly. They remained stable at high temperatures and high therapeutic doses over a long time. These unique features suggest that RNA 3WJ nanoparticles have the potential to be used for targeted radiation therapy for cancer treatment.« less

  13. Antibacterial activity of anthraquinone from cassia seed on spiced pig head

    NASA Astrophysics Data System (ADS)

    Xu, L. Y.; Li, X.; Cui, Y. Q.; Pang, M. X.; Wang, F.; Qi, J. H.

    2018-01-01

    [Objective] To optimize the extraction of anthraquinone from cassia seed by ultrasonic extraction and its antibacterial activity. [Method] The influences of different extraction time and ethanol concentration, on anthraquinone content were evaluated by a single factor experiment. And anthraquinone content was determined by ultraviolet spectrophotometry. The bacteriostasis of anthraquinone on spiced pig head’s common putrefying bacteria: Staphylococcus, Serratieae, Bacillus, Proteus and the minimal inhibitory concentration (MIC) were studied by oxford plate assay system. [Result] The best extraction time was 30 minutes and the best ethanol concentration was 80%. The antibacterial activity of the cassia seed anthraquinone on Staphylococcus Aureus, Bacillus Proteus is obviously, the minimum inhibitory concentrations were 0.125 g/mL, 0.125 g/mL, 1 g/mL respectively and no inhibitory effect on Serratieae. [Conclusions] The anthraquinones from Cassia seed can inhibit a part of spoilage bacteria in spiced pig heads.

  14. Edema and Seed Displacements Affect Intraoperative Permanent Prostate Brachytherapy Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westendorp, Hendrik, E-mail: r.westendorp@radiotherapiegroep.nl; Nuver, Tonnis T.; Department of Radiation Oncology, Radiotherapiegroep Behandellocatie Deventer, Deventer

    Purpose: We sought to identify the intraoperative displacement patterns of seeds and to evaluate the correlation of intraoperative dosimetry with day 30 for permanent prostate brachytherapy. Methods and Materials: We analyzed the data from 699 patients. Intraoperative dosimetry was acquired using transrectal ultrasonography (TRUS) and C-arm cone beam computed tomography (CBCT). Intraoperative dosimetry (minimal dose to 40%-95% of the volume [D{sub 40}-D{sub 95}]) was compared with the day 30 dosimetry for both modalities. An additional edema-compensating comparison was performed for D{sub 90}. Stranded seeds were linked between TRUS and CBCT using an automatic and fast linking procedure. Displacement patterns weremore » analyzed for each seed implantation location. Results: On average, an intraoperative (TRUS to CBCT) D{sub 90} decline of 10.6% ± 7.4% was observed. Intraoperative CBCT D{sub 90} showed a greater correlation (R{sup 2} = 0.33) with respect to Day 30 than did TRUS (R{sup 2} = 0.17). Compensating for edema, the correlation increased to 0.41 for CBCT and 0.38 for TRUS. The mean absolute intraoperative seed displacement was 3.9 ± 2.0 mm. The largest seed displacements were observed near the rectal wall. The central and posterior seeds showed less caudal displacement than lateral and anterior seeds. Seeds that were implanted closer to the base showed more divergence than seeds close to the apex. Conclusions: Intraoperative CBCT D{sub 90} showed a greater correlation with the day 30 dosimetry than intraoperative TRUS. Edema seemed to cause most of the systematic difference between the intraoperative and day 30 dosimetry. Seeds near the rectal wall showed the most displacement, comparing TRUS and CBCT, probably because of TRUS probe–induced prostate deformation.« less

  15. Computational and Experimental Evaluations of a Novel Thermo-Brachytherapy Seed for Treatment of Solid Tumors

    NASA Astrophysics Data System (ADS)

    Warrell, Gregory R.

    Hyperthermia has long been known as a radiation therapy sensitizer of high potential; however successful delivery of this modality and integrating it with radiation have often proved technically difficult. We present the dual-modality thermobrachytherapy (TB) seed, based on the ubiquitous low dose-rate (LDR) brachytherapy permanent implant, as a simple and effective combination of hyperthermia and radiation therapy. Heat is generated from a ferromagnetic or ferrimagnetic core within the seed, which produces Joule heating by eddy currents. A strategically-selected Curie temperature provides thermal self-regulation. In order to obtain a uniform and sufficiently high temperature distribution, additional hyperthermia-only (HT-only) seeds are proposed to be used in vacant spots within the needles used to implant the TB seeds; this permits a high seed density without the use of additional needles. Experimental and computational studies were done both to optimize the design of the TB and HT-only seeds and to quantitatively assess their ability to heat and irradiate defined, patient-specific targets. Experiments were performed with seed-sized ferromagnetic samples in tissue-mimicking phantoms heated by an industrial induction heater. The magnetic and thermal properties of the seeds were studied computationally in the finite element analysis (FEA) solver COMSOL Multiphysics, modelling realistic patient-specific seed distributions. These distributions were derived from LDR permanent prostate implants previously conducted at our institution; various modifications of the seeds' design were studied. The calculated temperature distributions were analyzed by generating temperature-volume histograms, which were used to quantify coverage and temperature homogeneity for a range of blood perfusion rates, as well as for a range of seed Curie temperatures and thermal power production rates. The impact of the interseed attenuation and scatter (ISA) effect on radiation dose distributions

  16. Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Colleen A., E-mail: clawton@mcw.edu; Hunt, Daniel; Lee, W. Robert

    2011-09-01

    Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to themore » prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design

  17. RNA Nanoparticles Derived from Three-Way Junction of Phi29 Motor pRNA Are Resistant to I-125 and Cs-131 Radiation

    PubMed Central

    Li, Hui; Rychahou, Piotr G.; Cui, Zheng; Pi, Fengmei; Evers, B. Mark; Shu, Dan

    2015-01-01

    Radiation reagents that specifically target tumors are in high demand for the treatment of cancer. The emerging field of RNA nanotechnology might provide new opportunities for targeted radiation therapy. This study investigates whether chemically modified RNA nanoparticles derived from the packaging RNA (pRNA) three-way junction (3WJ) of phi29 DNA-packaging motor are resistant to potent I-125 and Cs-131 radiation, which is a prerequisite for utilizing these RNA nanoparticles as carriers for targeted radiation therapy. pRNA 3WJ nanoparticles were constructed and characterized, and the stability of these nanoparticles under I-125 and Cs-131 irradiation with clinically relevant doses was examined. RNA nanoparticles derived from the pRNA 3WJ targeted tumors specifically and they were stable under irradiation of I-125 and Cs-131 with clinically relevant doses ranging from 1 to 90 Gy over a significantly long time up to 20 days, while control plasmid DNA was damaged at 20 Gy or higher. PMID:26017686

  18. DWDM-PON at 25 GHz channel spacing based on ASE injection seeding.

    PubMed

    Kim, Joon-Young; Moon, Sang-Rok; Yoo, Sang-Hwa; Lee, Chang-Hee

    2012-12-10

    We demonstrate a 25 GHz-channel-spaced DWDM-PON based on ASE injection seeding. A 60 km transmission at 1.25 Gb/s per channel is available with a 2nd generation FEC. The major limiting factor is the optical back reflection induced penalty. Thus a high gain reflective modulator and/or relocation of the seed light increase the transmission length. We demonstrated 90 km transmission with relocated seed light to remote node.

  19. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    PubMed

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  20. The effects of metallic implants on electroporation therapies: feasibility of irreversible electroporation for brachytherapy salvage.

    PubMed

    Neal, Robert E; Smith, Ryan L; Kavnoudias, Helen; Rosenfeldt, Franklin; Ou, Ruchong; Mclean, Catriona A; Davalos, Rafael V; Thomson, Kenneth R

    2013-12-01

    Electroporation-based therapies deliver brief electric pulses into a targeted volume to destabilize cellular membranes. Nonthermal irreversible electroporation (IRE) provides focal ablation with effects dependent on the electric field distribution, which changes in heterogeneous environments. It should be determined if highly conductive metallic implants in targeted regions, such as radiotherapy brachytherapy seeds in prostate tissue, will alter treatment outcomes. Theoretical and experimental models determine the impact of prostate brachytherapy seeds on IRE treatments. This study delivered IRE pulses in nonanimal, as well as in ex vivo and in vivo tissue, with and in the absence of expired radiotherapy seeds. Electrical current was measured and lesion dimensions were examined macroscopically and with magnetic resonance imaging. Finite-element treatment simulations predicted the effects of brachytherapy seeds in the targeted region on electrical current, electric field, and temperature distributions. There was no significant difference in electrical behavior in tissue containing a grid of expired radiotherapy seeds relative to those without seeds for nonanimal, ex vivo, and in vivo experiments (all p > 0.1). Numerical simulations predict no significant alteration of electric field or thermal effects (all p > 0.1). Histology showed cellular necrosis in the region near the electrodes and seeds within the ablation region; however, there were no seeds beyond the ablation margins. This study suggests that electroporation therapies can be implemented in regions containing small metallic implants without significant changes to electrical and thermal effects relative to use in tissue without the implants. This supports the ability to use IRE as a salvage therapy option for brachytherapy.

  1. Glucosinolate pattern in Isatis tinctoria and I. indigotica seeds.

    PubMed

    Mohn, Tobias; Hamburger, Matthias

    2008-06-01

    The glucosinolate patterns in seeds of five ISATIS TINCTORIA and two ISATIS INDIGOTICA accessions were assessed with a recently developed and validated LC-MS assay for direct analysis of glucosinolates without prior desulfatation. Glucosinolate peaks were identified with in-source fragmentation and detection of the sulfate anion ( M/Z = 97), and by MS/MS experiments. The glucosinolate patterns of the seeds showed characteristic differences compared to leaves. Glucoisatisin and epiglucoisatisin were diagnostic of seed samples. Qualitative and quantitative differences in glucosinolate patterns between both ISATIS species were found for seed samples, enabling a differentiation of the two medicinal plants at the level of seed material.

  2. Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golshan, Maryam, E-mail: maryam.golshan@bccancer.bc.ca; Spadinger, Ingrid; Chng, Nick

    2016-06-15

    Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of amore » flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry

  3. Numerical simulation of airborne cloud seeding over Greece, using a convective cloud model

    NASA Astrophysics Data System (ADS)

    Spiridonov, Vlado; Karacostas, Theodore; Bampzelis, Dimitrios; Pytharoulis, Ioannis

    2015-02-01

    An extensive work has been done by the Department of Meteorology and Climatology at Aristotle University of Thessaloniki and others using a three-dimensional cloud resolving model to simulate AgI seeding by aircraft of three distinct hailstorm cases occurred over Greece in period 2007-2009. The seeding criterion for silver iodide glaciogenic seeding from air is based on the beneficial competition mechanism. According to thermodynamic analysis and classification proposed by Marwitz (1972a, b, and c) and based on their structural and evolutionary properties we classified them in three groups as singlecell, multicell and supercell hailstorms. The seeding optimization for each selected case is conducted by analysis of the thermodynamic characteristics of the meteorological environment as well as radar reflectivity fields observed by the state of the art Thunderstorm Identification, Tracking, Analysis and Nowcasting (TITAN) software applied in the Greek National Hail Suppression Program (GNHSP). Results of this comprehensive study have shown positive effects with respect to hailfall decrease after successful seeding as our primarily objective. All three cases have illustrated 15-20% decrease in accumulated hailfall at the ground Seeded clouds have exhibited earlier development of precipitation and slight dynamical enhancement of the updraft and rainfall increase of ~10- 12.5%. The results have emphasized a strong interaction between cloud dynamics and microphysics, especially the subgrid scale processes that have impact on agent transport and diffusion in a complex environment. Comparisons between modelled and observed radar reflectivity also show a relatively good agreement. Simulated cloud seeding follows the operational aircraft seeding for hail suppression. The ability of silver-iodide particles to act as ice nuclei has been used to perform airborne cloud seeding, under controlled conditions of temperature and humidity. The seeding effects depend upon applying the

  4. HCG-. beta. -subunit radioimmunoassay: potential error in HCG measurement related to choice of labeled antigen. [/sup 125/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyrey, L.; Hammond, C.B.

    1976-05-15

    Antiserum generated against the hormone-specific ..beta..-subunit of hCG was used with different labeled antigens to measure circulating hCG in patients having trophoblastic disease. When /sup 125/I-hCG..beta.. served as the labeled antigen, a small number of patient sera failed to show parallelism with the second IS-hCG reference and erroneous estimates of hormone concentrations were obtained. Replacement of the /sup 125/I-hCG..beta.. with labeled hCG corrected the nonparallelism exhibited by these samples. Inhibition curves obtained with purified hCG and hCG..beta.. suggested that both the nonparallelism and its correction with the change in labeled antigen would be consistent with the possibility that this assaymore » aberration may result from the presence of free hCG..beta.. in these sera. (auth)« less

  5. Evaluation of new iodinated acridine derivatives for targeted radionuclide therapy of melanoma using 125I, an Auger electron emitter.

    PubMed

    Gardette, Maryline; Papon, Janine; Bonnet, Mathilde; Desbois, Nicolas; Labarre, Pierre; Wu, Ting-Dee; Miot-Noirault, Elisabeth; Madelmont, Jean-Claude; Guerquin-Kern, Jean-Luc; Chezal, Jean-Michel; Moins, Nicole

    2011-12-01

    The increasing incidence of melanoma and the lack of effective therapy on the disseminated form have led to an urgent need for new specific therapies. Several iodobenzamides or analogs are known to possess specific affinity for melanoma tissue. New heteroaromatic derivatives have been designed with a cytotoxic moiety and termed DNA intercalating agents. These compounds could be applied in targeted radionuclide therapy using (125)I, which emits Auger electrons and gives high-energy, localized irradiation. Two iodinated acridine derivatives have been reported to present an in vivo kinetic profile conducive to application in targeted radionuclide therapy. The aim of the present study was to perform a preclinical evaluation of these compounds. The DNA intercalating property was confirmed for both compounds. After radiolabeling with (125)I, the two compounds induced in vitro a significant radiotoxicity to B16F0 melanoma cells. Nevertheless, the acridine compound appeared more radiotoxic than the acridone compound. While cellular uptake was similar for both compounds, SIMS analysis and in vitro protocol showed a stronger affinity for melanin with acridone derivative, which was able to induce a predominant scavenging process in the melanosome and restrict access to the nucleus. In conclusion, the acridine derivative with a higher nuclear localization appeared a better candidate for application in targeted radionuclide therapy using (125)I.

  6. Effect of 1,25-dihydroxyvitamin D3 on plasma concentrations of calcium-binding protein in normal and rachitic (vitamin D-dependent rickets type I) pigs.

    PubMed

    Maunder, E M; Pillay, A V; Care, A D

    1987-10-01

    An i.v. injection of calcitriol (1,25-(OH)2D3) had no effect within 2.5 h on plasma concentrations of calbindin-D9K (vitamin D-induced calcium-binding protein; CaBP) in hypocalcaemic pigs with inherited vitamin D-dependent rickets type I or in their normocalcaemic siblings or half-siblings. Three days later the plasma concentration of CaBP had doubled in the hypocalcaemic pigs, but was unaltered in the normocalcaemic siblings and half-siblings. Following daily i.v. injections of 1,25-(OH)2D3 for a further 5 days (days 4-8) plasma concentrations of CaBP increased in both the hypocalcaemic (days 4-8) and normocalcaemic (day 8) pigs, the effect being more rapid and greater in the hypocalcaemic 1,25-(OH)2D3-deficient animals. An i.v. injection of 1,25-(OH)2D3 to pure Yucatan pigs also had no effect on plasma concentrations of CaBP within 1.5 h, but in the following 1 h there was some indication of an increase in plasma CaBP levels. In contrast to the normal pigs, insulin-induced hypoglycaemia did not lead to a peak in plasma CaBP concentrations in the hypocalcaemic pigs. There was also no change in the plasma concentrations of 1,25-(OH)2D3 associated with the peak in plasma CaBP following insulin-induced hypoglycaemia in normocalcaemic pigs. These results suggest that changes in plasma concentrations of 1,25-(OH)2D3 are not directly involved in mediating the increase in plasma CaBP which follows hypoglycaemia induced by insulin in normal pigs, although 1,25-(OH)2D3 probably plays a permissive role.

  7. [Breast reconstruction: autologous tissue versus implant].

    PubMed

    Plogmeier, K; Handstein, S; Schneider, W

    1998-01-01

    Modified radical mastectomy remains the standard for treatment of breast cancer. Women faced with the diagnosis of breast cancer often find it difficult to cope with the arousing emotions. Fear of death or cancer recurrence and a perceived loss of femininity often coexists with the desire for a return to normality and wholeness. For women seeking breast reconstruction various techniques have been developed. Two different ways for breast reconstruction have become a standard. One way is the reconstruction by tissue expansion or transposing locally available tissue with the use of implants. The other way is the reconstruction of the breast without using any implants with the Latissimus dorsi flap or the TRAM flap. We performed 291 breast reconstructions. In 125 women available tissue and an implant was used. The Latissimus dorsi flap was used in 57 cases and 109 TRAM flaps either pedicled or as a microvascular flap were performed. Using expanders we found a perforation of the device in 2 cases. After using implants there were capsular contracture in 2 cases and in 1 case we had an infection. Using autologous tissue we had 2 partial flap necrosis, 4 hematomas, and 4 prolonged healings. There was no complete flap necrosis. Breast reconstruction using autologous tissue i.e. the TRAM flap is supposed to be a standard technique. Microsurgical transplantation of the TRAM flap shows almost no morbidity of the donor site area. Autologous tissue follows the changes of the body like weight gain or reduction to a certain extend and shows neither capsular contracture nor other implant associated side effects. Women get the impression that the TRAM flap is like soft tissue to the touch and not like a foreign body. The aesthetic results were in all cases superior sometimes needing minor secondary correction and mostly shaping of the nippel-areola complex. All patients were pleased with the result.

  8. Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography.

    PubMed

    Razavi, Touraj; Palmer, Richard M; Davies, Jonathan; Wilson, Ron; Palmer, Paul J

    2010-07-01

    To assess the accuracy of measuring the cortical bone thickness adjacent to dental implants using two cone beam computed tomography (CBCT) systems. Ten 4 x 11 mm Astra Tech implants were placed at varying distances from the cortical bone in two prepared bovine ribs. Both ribs were scanned in a reproducible position using two different CBCT scanners. Ten examiners each carried out four measurements on all 10 implants using the two CBCT systems: vertical distance between the top of the implant and the alveolar crest (IT-AC), and thickness of the cortical bone from the outer surface of the implant threads at 3, 6 and 9 mm from the top of the implant. Ground sections were prepared and bone thickness was measured using a light microscope and a graticule to give a gold standard (GS) measurement. The examiner's measurements were significantly different between CBCT systems for the vertical and thickness dimensions (P<0.001) while measuring the cortical bone thickness between 0.3 and 3.7 mm. Within that range, i-CAT NG measurements were consistently underestimated in comparison with the GS. Accuitomo 3D60 FPD measurements closely approximated the GS, except when cortical bone thickness was <0.8 mm. The mean percentage errors from the GS at 3, 6 and 9 mm measurement levels were 68%, 28% and 18%, respectively, for i-CAT NG and 23%, 5% and 6%, respectively, for Accuitomo 3D60 FPD. Within the limitations of this study, it was concluded that i-CAT NG (voxel size 0.3) may not produce sufficient resolution of the thin cortical bone adjacent to dental implants and, therefore, the measurements may not be accurate; whereas, Accuitomo 3D60 FPD (voxel size 0.125) may produce better resolution and more accurate measurement of the thin bone.

  9. The behavior of the radar parameters of cumulonimbus clouds during cloud seeding with AgI

    NASA Astrophysics Data System (ADS)

    Vujović, D.; Protić, M.

    2017-06-01

    Deep convection yielding severe weather phenomena (hail, flash floods, thunder) is frequent in Serbia during the warmer part of the year, i.e. April to September. As an effort to mitigate any potential damage to material goods, agricultural crops and vegetation from larger hailstones, cloud seeding is performed. In this paper, we analyzed 29 severe hailstorms seeded by silver iodide. From these, we chose five intense summer thunderstorm cells to analyze in detail the influence of silver-iodide cloud seeding on the radar parameters. Four of them were seeded and one was not. We also used data from firing stations (hail fall occurrence, the size of the hailstones). The most sensitive radar parameter in seeding was the height where maximum reflectivity in the cloud was observed. Its cascade appeared in every case of seeding, but was absent from the non-seeded case. In the case of the supercell, increase and decrease of the height where maximum reflectivity in the cloud was observed occurred in almost regular intervals, 12 to 15 min. The most inert parameter in seeding was maximum radar reflectivity. It changed one to two dBz during one cycle. The height of the top of the cloud and the height of the zone exhibiting enhanced radar echo both had similar behavior. It seems that both increased after seeding due to a dynamic effect: upward currents increasing due to the release of latent heat during the freezing of supercooled droplets. Mean values of the height where maximum reflectivity in the cloud was observed, the height of the top of the cloud and the height of the zone exhibiting enhanced radar echo during seeded period were greater than during unseeded period in 75.9%, 72.4% and 79.3% cases, respectively. This is because the values of the chosen storm parameters were higher when the seeding started, and then those values decreased after the seeded was conducted.

  10. Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy

    NASA Astrophysics Data System (ADS)

    Park, Seyoun; Song, Danny Y.; Lee, Junghoon

    2016-03-01

    Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.

  11. The Effects of Metallic Implants on Electroporation Therapies: Feasibility of Irreversible Electroporation for Brachytherapy Salvage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neal, Robert E., E-mail: robert.neal@alfred.org.au; Smith, Ryan L., E-mail: ryan.smith@wbrc.org.au; Kavnoudias, Helen, E-mail: H.Kavnoudias@alfred.org.au

    2013-12-15

    Purpose: Electroporation-based therapies deliver brief electric pulses into a targeted volume to destabilize cellular membranes. Nonthermal irreversible electroporation (IRE) provides focal ablation with effects dependent on the electric field distribution, which changes in heterogeneous environments. It should be determined if highly conductive metallic implants in targeted regions, such as radiotherapy brachytherapy seeds in prostate tissue, will alter treatment outcomes. Theoretical and experimental models determine the impact of prostate brachytherapy seeds on IRE treatments. Materials and Methods: This study delivered IRE pulses in nonanimal, as well as in ex vivo and in vivo tissue, with and in the absence of expiredmore » radiotherapy seeds. Electrical current was measured and lesion dimensions were examined macroscopically and with magnetic resonance imaging. Finite-element treatment simulations predicted the effects of brachytherapy seeds in the targeted region on electrical current, electric field, and temperature distributions. Results: There was no significant difference in electrical behavior in tissue containing a grid of expired radiotherapy seeds relative to those without seeds for nonanimal, ex vivo, and in vivo experiments (all p > 0.1). Numerical simulations predict no significant alteration of electric field or thermal effects (all p > 0.1). Histology showed cellular necrosis in the region near the electrodes and seeds within the ablation region; however, there were no seeds beyond the ablation margins. Conclusion: This study suggests that electroporation therapies can be implemented in regions containing small metallic implants without significant changes to electrical and thermal effects relative to use in tissue without the implants. This supports the ability to use IRE as a salvage therapy option for brachytherapy.« less

  12. A Stem Cell-Seeded Nanofibrous Scaffold for Auditory Nerve Replacement

    DTIC Science & Technology

    2015-10-01

    guinea pigs . Initial results show improved electrically-evoked auditory brainstem responses in cell-seeded implants compared to control, cell-free...scaffold’s conduit, but the IAM of the guinea pig and limits imposed by the surgical approach make this difficult. Alternatives are being pursued...transplantation of the seeded nanofibrous scaffold Task 13. Group 1: Pilot deafening. Confirm efficacy of ß-bungarotoxin in guinea pig and time point of

  13. Toward angiogenesis of implanted bio-artificial liver using scaffolds with type I collagen and adipose tissue-derived stem cells

    PubMed Central

    Lee, Jae Geun; Bak, Seon Young; Nahm, Ji Hae; Lee, Sang Woo; Min, Seon Ok

    2015-01-01

    Backgrounds/Aims Stem cell therapies for liver disease are being studied by many researchers worldwide, but scientific evidence to demonstrate the endocrinologic effects of implanted cells is insufficient, and it is unknown whether implanted cells can function as liver cells. Achieving angiogenesis, arguably the most important characteristic of the liver, is known to be quite difficult, and no practical attempts have been made to achieve this outcome. We carried out this study to observe the possibility of angiogenesis of implanted bio-artificial liver using scaffolds. Methods This study used adipose tissue-derived stem cells that were collected from adult patients with liver diseases with conditions similar to the liver parenchyma. Specifically, microfilaments were used to create an artificial membrane and maintain the structure of an artificial organ. After scratching the stomach surface of severe combined immunocompromised (SCID) mice (n=4), artificial scaffolds with adipose tissue-derived stem cells and type I collagen were implanted. Expression levels of angiogenesis markers including vascular endothelial growth factor (VEGF), CD34, and CD105 were immunohistochemically assessed after 30 days. Results Grossly, the artificial scaffolds showed adhesion to the stomach and surrounding organs; however, there was no evidence of angiogenesis within the scaffolds; and VEGF, CD34, and CD105 expressions were not detected after 30 days. Conclusions Although implantation of cells into artificial scaffolds did not facilitate angiogenesis, the artificial scaffolds made with type I collagen helped maintain implanted cells, and surrounding tissue reactions were rare. Our findings indicate that type I collagen artificial scaffolds can be considered as a possible implantable biomaterial. PMID:26155277

  14. Toward angiogenesis of implanted bio-artificial liver using scaffolds with type I collagen and adipose tissue-derived stem cells.

    PubMed

    Lee, Jae Geun; Bak, Seon Young; Nahm, Ji Hae; Lee, Sang Woo; Min, Seon Ok; Kim, Kyung Sik

    2015-05-01

    Stem cell therapies for liver disease are being studied by many researchers worldwide, but scientific evidence to demonstrate the endocrinologic effects of implanted cells is insufficient, and it is unknown whether implanted cells can function as liver cells. Achieving angiogenesis, arguably the most important characteristic of the liver, is known to be quite difficult, and no practical attempts have been made to achieve this outcome. We carried out this study to observe the possibility of angiogenesis of implanted bio-artificial liver using scaffolds. This study used adipose tissue-derived stem cells that were collected from adult patients with liver diseases with conditions similar to the liver parenchyma. Specifically, microfilaments were used to create an artificial membrane and maintain the structure of an artificial organ. After scratching the stomach surface of severe combined immunocompromised (SCID) mice (n=4), artificial scaffolds with adipose tissue-derived stem cells and type I collagen were implanted. Expression levels of angiogenesis markers including vascular endothelial growth factor (VEGF), CD34, and CD105 were immunohistochemically assessed after 30 days. Grossly, the artificial scaffolds showed adhesion to the stomach and surrounding organs; however, there was no evidence of angiogenesis within the scaffolds; and VEGF, CD34, and CD105 expressions were not detected after 30 days. Although implantation of cells into artificial scaffolds did not facilitate angiogenesis, the artificial scaffolds made with type I collagen helped maintain implanted cells, and surrounding tissue reactions were rare. Our findings indicate that type I collagen artificial scaffolds can be considered as a possible implantable biomaterial.

  15. Scatter Hoarding of Seeds Confers Survival Advantages and Disadvantages to Large-Seeded Tropical Plants at Different Life Stages

    PubMed Central

    Kuprewicz, Erin K.

    2015-01-01

    Scatter hoarding of seeds by animals contributes significantly to forest-level processes, including plant recruitment and forest community composition. However, the potential positive and negative effects of caching on seed survival, germination success, and seedling survival have rarely been assessed through experimental studies. Here, I tested the hypothesis that seed burial mimicking caches made by scatter hoarding Central American agoutis (Dasyprocta punctate) enhances seed survival, germination, and growth by protecting seeds from seed predators and providing favorable microhabitats for germination. In a series of experiments, I used simulated agouti seed caches to assess how hoarding affects seed predation by ground-dwelling invertebrates and vertebrates for four plant species. I tracked germination and seedling growth of intact and beetle-infested seeds and, using exclosures, monitored the effects of mammals on seedling survival through time. All experiments were conducted over three years in a lowland wet forest in Costa Rica. The majority of hoarded palm seeds escaped predation by both invertebrates and vertebrates while exposed seeds suffered high levels of infestation and removal. Hoarding had no effect on infestation rates of D. panamensis, but burial negatively affected germination success by preventing endocarp dehiscence. Non-infested palm seeds had higher germination success and produced larger seedlings than infested seeds. Seedlings of A. alatum and I. deltoidea suffered high mortality by seed-eating mammals. Hoarding protected most seeds from predators and enhanced germination success (except for D. panamensis) and seedling growth, although mammals killed many seedlings of two plant species; all seedling deaths were due to seed removal from the plant base. Using experimental caches, this study shows that scatter hoarding is beneficial to most seeds and may positively affect plant propagation in tropical forests, although tradeoffs in seed

  16. A one-pot radioiodination of aryl amines via stable diazonium salts: preparation of 125I-imaging agents.

    PubMed

    Sloan, Nikki L; Luthra, Sajinder K; McRobbie, Graeme; Pimlott, Sally L; Sutherland, Andrew

    2017-10-05

    An operationally simple, one-pot, two-step tandem procedure that allows the incorporation of radioactive iodine into aryl amines via stable diazonium salts is described. The mild conditions are tolerant of various functional groups and substitution patterns, allowing late-stage, rapid access to a wide range of 125 I-labelled aryl compounds and SPECT radiotracers.

  17. Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

    PubMed

    Pokhrel, Damodar; Murphy, Martin J; Todor, Dorin A; Weiss, Elisabeth; Williamson, Jeffrey F

    2010-09-01

    To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four 103Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. For the phantom study, seed localization error is (0.58 +/- 0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/ iteration on a 1 GHz processor. The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate approximately 1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

  18. Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.

    2010-09-15

    Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selectedmore » from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.« less

  19. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of thesemore » selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.« less

  20. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    PubMed

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  1. Evaluation of the Coat-A-Count sup 125 I fentanyl RIA: Comparison of sup 12 5I RIA and GC/MS-SIM for quantification of fentanyl in case urine specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watts, V.W.; Caplan, Y.H.

    The Coat-A-Count solid phase {sup 125}I Fentanyl Radioimmunoassay was evaluated with respect to linearity and precision using equine urine fortified with fentanyl and then compared with a gas chromatographic/mass spectrometric method for quantification of fentanyl in urine. The RIA assay was found to be linear over the urine fentanyl concentration range of 0.25 to 7.5 ng/mL and precise with coefficients of variation (CV) ranging from 9.6 to 19.3%. The RIA calibrators, ranging in fentanyl concentrations from 0.25 to 7.5 ng/mL, and controls, at mean fentanyl concentrations of 0.46 and 1.32 ng/mL, were compared by both the RIA and GC/MS methods.more » The cross-reactivity with the {sup 125}I RIA test was determined for the fentanyl metabolites, norfentanyl and hydroxyfentanyl, and found to be 5% and 35%, respectively. The illicit fentanyl analogs were found to show significant cross-reactivity, ranging from 20 to 100%. The {sup 125}I RIA was compared to GC/MS quantifications of fentanyl in 35 positive and 20 negative case urine specimens.« less

  2. Dexamethasone effects on (/sup 125/I)albumin distribution in experimental RG-2 gliomas and adjacent brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakagawa, H.; Groothuis, D.R.; Owens, E.S.

    1987-12-01

    A total of 72 RG-2 transplanted gliomas were studied in 58 rats at three time points (1, 30, 240 min) after intravenous injection of (/sup 125/I)radioiodinated serum albumin ((/sup 125/I)RISA). The animals were divided into two groups: a control group that received no treatment and a second group that was treated with five doses of 1.5 mg/kg of dexamethasone over 2.5 days. Local tissue concentrations of (/sup 125/I)RISA were measured with quantitative autoradiography based on morphological features of the tumors and used to calculate the tissue distribution space. Two models were used to analyze the data. A two compartment modelmore » yielded estimates of local blood-to-tissue influx constants (K1), lower limit extracellular volumes (Ve), and plasma vascular volumes (Vp) in different tumor regions. Treatment with dexamethasone consistently reduced the RISA distribution space in the RG-2 tumors; the reduction in Ve was statistically significant in almost all tumor regions: whole tumor Ve (mean +/- SE) was reduced from 0.14 +/- 0.02 ml g-1 in control animals to 0.08 +/- 0.01 ml g-1 in dexamethasone treated animals. K1 and Vp were also decreased in all tumor regions after treatment with dexamethasone (whole tumor K1 decreased from 2.36 +/- 0.89 to 0.83 +/- 0.29 microliter g-1 min-1 and Vp decreased slightly from 0.016 +/- 0.013 to 0.010 +/- 0.005 ml g-1 after dexamethasone treatment), but these changes were not statistically significant. A comparison of the tumor influx constants in control animals and the aqueous diffusion constants of two different size molecules (RISA and aminoisobutyric acid) suggests that the ''pores'' across RG-2 capillaries are large and may not restrict the free diffusion of RISA (estimated minimum pore diameter greater than 36 nm) and that the total pore area is approximately 6.2 X 10(-5) cm2 g-1 in RG-2 tumor tissue.« less

  3. Distribution of Non-AT1, Non-AT2 Binding of 125I-Sarcosine1, Isoleucine8 Angiotensin II in Neurolysin Knockout Mouse Brains

    PubMed Central

    Speth, Robert C.; Carrera, Eduardo J.; Bretón, Catalina; Linares, Andrea; Gonzalez-Reiley, Luz; Swindle, Jamala D.; Santos, Kira L.; Schadock, Ines; Bader, Michael; Karamyan, Vardan T.

    2014-01-01

    The recent identification of a novel binding site for angiotensin (Ang) II as the peptidase neurolysin (E.C. 3.4.24.16) has implications for the renin-angiotensin system (RAS). This report describes the distribution of specific binding of 125I-Sarcosine1, Isoleucine8 Ang II (125I-SI Ang II) in neurolysin knockout mouse brains compared to wild-type mouse brains using quantitative receptor autoradiography. In the presence of p-chloromercuribenzoic acid (PCMB), which unmasks the novel binding site, widespread distribution of specific (3 µM Ang II displaceable) 125I-SI Ang II binding in 32 mouse brain regions was observed. Highest levels of binding >700 fmol/g initial wet weight were seen in hypothalamic, thalamic and septal regions, while the lowest level of binding <300 fmol/g initial wet weight was in the mediolateral medulla. 125I-SI Ang II binding was substantially higher by an average of 85% in wild-type mouse brains compared to neurolysin knockout brains, suggesting the presence of an additional non-AT1, non-AT2, non-neurolysin Ang II binding site in the mouse brain. Binding of 125I-SI Ang II to neurolysin in the presence of PCMB was highest in hypothalamic and ventral cortical brain regions, but broadly distributed across all regions surveyed. Non-AT1, non-AT2, non-neurolysin binding was also highest in the hypothalamus but had a different distribution than neurolysin. There was a significant reduction in AT2 receptor binding in the neurolysin knockout brain and a trend towards decreased AT1 receptor binding. In the neurolysin knockout brains, the size of the lateral ventricles was increased by 56% and the size of the mid forebrain (−2.72 to +1.48 relative to Bregma) was increased by 12%. These results confirm the identity of neurolysin as a novel Ang II binding site, suggesting that neurolysin may play a significant role in opposing the pathophysiological actions of the brain RAS and influencing brain morphology. PMID:25147932

  4. Insecticide seed treatments for sugarbeet

    USDA-ARS?s Scientific Manuscript database

    Pest feeding and vectoring of viruses cause serious problems in sugarbeet production worldwide. In order to ameliorate pest and disease problems on sugarbeet, two seed treatments, Poncho Beta (60 g a.i. clothianidin + 8 g a.i. beta-cyfluthrin/100,000 seed) and Cruiser Tef (60 g a.i. thiamethoxam + 8...

  5. Follitropin receptors in rat testis. Characterization with enzymatically 125I-labeled human follitropin.

    PubMed

    Ketelslegers, J M; Catt, K J

    1978-07-03

    The interaction between enzymatically radioiodinated human follitropin and the follitropin receptors in testis homogenate was investigated in immature and adult rats. The 125I-labeled human follitropin exhibited high binding activity with specific binding of up to 17% in the presence of an excess of testis homogenate. Approx. 50% of the bound hormone could be eluted at pH 5, and the receptor purified tracer exhibited a 3.6-fold increase in binding activity when compared with the original tracer preparation. Quantitative analysis of equilibrium binding data was performed with corrections for the measured specific activity and maximum binding activity of the tracer hormone. The equilibrium association constants (Ka) determined 24 degrees C were not significantly different in immature and adult rat testis, and the mean value for Ka was 3.9 . 10(9) M-1. At 37 degrees C, the Ka value obtained using immature rat testis was 1.3 . 10(10) M-1. The association of 125I-labeled human follitropin with immature rat testis homogenate was time and temperature dependent. In the presence of an excess of unlabeled hormone, 30--60% of the preformed hormone . receptor complex was dissociated after 24 h incubation. A specific and sensitive radioligand-receptor assay for follitropin was developed using immature rat testis homogenate. The minimum detectable dose of purified human follitropin was 0.6 ng, and human urinary and pituitary follitropin, ovine follitropin and pregnant mare serum gonadotropin reacted in the assay with equivalent slopes. The potencies of highly purified pregnent mare serum gonadotropin and highly purified human follitropin were similar in the radioligand-receptor assay, consistent with the follitropin bioactivity of the equine gonadotropin.

  6. Evaluation of inductively heated ferromagnetic alloy implants for therapeutic interstitial hyperthermia.

    PubMed

    Paulus, J A; Richardson, J S; Tucker, R D; Park, J B

    1996-04-01

    Ferromagnetic alloys heated by magnetic induction have been investigated as interstitial hyperthermia delivery implants for over a decade, utilizing low Curie temperatures to provide thermal self-regulation. The minimally invasive method is attractive for fractionated thermal treatment of tumors which are not easily heated by focused microwave or ultrasound techniques. Past analyses of ferromagnetic seeds by other authors depict poor experimental correlation with theoretical heating predictions. Improvements in computer hardware and commercially available finite element analysis software have simplified the analysis of inductively heated thermal seeds considerably. This manuscript examines end effects of finite length implants and nonlinear magnetic material properties to account for previous inconsistencies. Two alloys, Ni-28 wt% Cu (NiCu) and Pd-6.15 wt% Co (PdCo), were used for comparison of theoretical and experimental calorimetric results. Length to diameter (L/d) ratios of over 20 for cylindrical seeds are necessary for minimization of end effects. Magnetic properties tested for alloys of NiCu and PdCo illustrate considerable nonlinearity of these materials in field strength ranges used for induction heating. Field strength dependent magnetic permeabilities and calorimetric data illustrate that more detailed material information must be included to accurately estimate induction power loss for these implants.

  7. Review of the poster "Dosimetric comparison of gamma knife radiosurgery vs. 125I plaque brachytherapy in a cohort of choroidal melanomas".

    PubMed

    Odell, Kelly R

    2009-01-01

    Historically, treatment for choroidal melanomas was surgical enucleation. Currently, treatment methods such as stereotactic radiosurgery and brachytherapy are being used to spare the eye. The poster "Dosimetric Comparison of Gamma Knife Radiosurgery vs. I-125 Plaque Brachytherapy in a Cohort of Choroidal Melanomas" presented at ASTRO 2007 by Anderson et al. provides a comparison of these methods. The dose to disk, fovea and lens in 29 patients from a simulated I-125 treatment and a delivered Gamma Knife radiosurgery was compared. Thirty Gy was prescribed to the 50% Isodose line in the radiosurgery and 85 Gy was prescribed to the apex of the tumor in the I-125 simulation. It was found that the Gamma Knife spares the disk better in 59% of the tumors, including those >or=6.5 mm in height; spares the fovea better in 69% of the tumors, including those >or=5.5 mm; and spares lens better in only 30% of the tumors, with no distinction in size. Tumor location was not taken into account for this study, which could explain the variations in smaller tumors. For larger tumors, gamma knife will protect most organs at risk more effectively. This study shows how a tumor's parameters can be used in selecting treatment modality.

  8. Effects of age and clustered hypoxia on [(125)I] substance P binding to neurotachykinin-1 receptors in brainstem of developing swine.

    PubMed

    Rodier, M E; Laferrière, A; Moss, I R

    2001-03-29

    This work focused on the postnatal development of substance P-bound neurotachykinin-1 (NK-1) receptors in the porcine brainstem using 2-3-, 6-11-, 16-18-, and 21-28-day-old piglets versus adult, and on alterations in these receptors after single and six-daily repeated clustered hypoxia using 6-11- and 21-28-day-old piglets. NK-1 receptor localization and densities were determined by quantitative autoradiography using mono-iodinated Bolton-Hunter substance P ([(125)I]BHSP). Slide-mounted brainstem sections, incubated in [(125)I]BHSP and then exposed to film, have shown [(125)I]BHSP binding throughout many brainstem nuclei and tracts, including the ambigual/periambigual (nAmb), dorsal motor vagal (dmnv), gigantocellular (nGC), hypoglossal (nHyp), medial parabrachial (nPBM), lateral reticular (nRL), raphe magnus (nRMg), raphe obscurus (nROb) and solitary tract (nTS) nuclei. NK-1 receptor densities decreased with age. As compared to normoxia, NK-1 receptor densities increased significantly after the six-daily hypoxia protocol in nAmb, dmnv, nHyp, nRL, nRMg, nROb, and nTS of both the young and older age groups. This increase may represent receptor upregulation as an adaptation to repeated hypoxia.

  9. 31 CFR 1.25 - Accounting of disclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Accounting of disclosures. 1.25... Privacy Act § 1.25 Accounting of disclosures. (a) Accounting of certain disclosures. Each component, with respect to each system of records under its control, shall: (1) Keep an accurate accounting of: (i) The...

  10. Experimental and theoretical studies of implant assisted magnetic drug targeting

    NASA Astrophysics Data System (ADS)

    Aviles, Misael O.

    One way to achieve drug targeting in the body is to incorporate magnetic nanoparticles into drug carriers and then retain them at the site using an externally applied magnetic field. This process is referred to as magnetic drug targeting (MDT). However, the main limitation of MDT is that an externally applied magnetic field alone may not be able to retain a sufficient number of magnetic drug carrier particles (MDCPs) to justify its use. Such a limitation might not exist when high gradient magnetic separation (HGMS) principles are applied to assist MDT by means of ferromagnetic implants. It was hypothesized that an Implant Assisted -- MDT (IA-MDT) system would increase the retention of the MDCPs at a target site where an implant had been previously located, since the magnetic forces are produced internally. With this in mind, the overall objective of this work was to demonstrate the feasibility of an IA-MDT system through mathematical modeling and in vitro experimentation. The mathematical models were developed and used to demonstrate the behavior and limitations of IA-MDT, and the in vitro experiments were designed and used to validate the models and to further elucidate the important parameters that affect the performance of the system. IA-MDT was studied with three plausible implants, ferromagnetic stents, seed particles, and wires. All implants were studied theoretically and experimentally using flow through systems with polymer particles containing magnetite nanoparticles as MDCPs. In the stent studies, a wire coil or mesh was simply placed in a flow field and the capture of the MDCPs was studied. In the other cases, a porous polymer matrix was used as a surrogate capillary tissue scaffold to study the capture of the MDCPs using wires or particle seeds as the implant, with the seeds either fixed within the polymer matrix or captured prior to capturing the MDCPs. An in vitro heart tissue perfusion model was also used to study the use of stents. In general, all

  11. Developing Implantable Neuroprosthetics: a New Model in Pig

    PubMed Central

    Yin, Ming; Aceros, Juan; Agha, Naubahar; Minxha, Juri; Komar, Jacob; Patterson, William; Bull, Christopher; Nurmikko, Arto

    2014-01-01

    A new model has been established in the domestic pig for neural prosthetic device development and testing. To this end, we report on a complete neural prosthetic developmental system using a wireless sensor as the implant, a pig as the animal model, and a novel data acquisition paradigm for actuator control. A new type of stereotactic frame with clinically-inspired fixations pins that place the pig brain in standard surgical plane was developed and tested with success during the implantation of the microsystem. The microsystem implanted was an ultralow power (12.5mW) 16-channel intracortical/epicranial device transmitting broadband (40kS/s) data over a wireless infrared telemetric link. Pigs were implanted and neural data was collected over a period of 5 weeks, clearly showing single unit spiking activity. PMID:22254977

  12. Developing implantable neuroprosthetics: a new model in pig.

    PubMed

    Borton, David; Yin, Ming; Aceros, Juan; Agha, Naubahar; Minxha, Juri; Komar, Jacob; Patterson, William; Bull, Christopher; Nurmikko, Arto

    2011-01-01

    A new model has been established in the domestic pig for neural prosthetic device development and testing. To this end, we report on a complete neural prosthetic developmental system using a wireless sensor as the implant, a pig as the animal model, and a novel data acquisition paradigm for actuator control. A new type of stereotactic frame with clinically-inspired fixations pins that place the pig brain in standard surgical plane was developed and tested with success during the implantation of the microsystem. The microsystem implanted was an ultra-low power (12.5 mW) 16-channel intracortical/epicranial device transmitting broadband (40 kS/s) data over a wireless infrared telemetric link. Pigs were implanted and neural data was collected over a period of 5 weeks, clearly showing single unit spiking activity.

  13. Method for the simultaneous preparation of radon-211, xenon-125, xenon-123, astatine-211, iodine-125 and iodine-123

    DOEpatents

    Mirzadeh, S.; Lambrecht, R.M.

    1985-07-01

    The invention relates to a practical method for commercially producing radiopharmaceutical activities and, more particularly, relates to a method for the preparation of about equal amount of Radon-211 (/sup 211/Rn) and Xenon-125 (/sup 125/Xe) including a one-step chemical procedure following an irradiation procedure in which a selected target of Thorium (/sup 232/Th) or Uranium (/sup 238/U) is irradiated. The disclosed method is also effective for the preparation in a one-step chemical procedure of substantially equal amounts of high purity /sup 123/I and /sup 211/At. In one preferred arrangement of the invention almost equal quantities of /sup 211/Rn and /sup 125/Xe are prepared using a onestep chemical procedure in which a suitably irradiated fertile target material, such as thorium-232 or uranium-238, is treated to extract those radionuclides from it. In the same one-step chemical procedure about equal quantities of /sup 211/At and /sup 123/I are prepared and stored for subsequent use. In a modified arrangement of the method of the invention, it is practiced to separate and store about equal amounts of only /sup 211/Rn and /sup 125/Xe, while preventing the extraction or storage of the radionuclides /sup 211/At and /sup 123/I.

  14. ERRATUM: In vivo evaluation of a neural stem cell-seeded prosthesis In vivo evaluation of a neural stem cell-seeded prosthesis

    NASA Astrophysics Data System (ADS)

    Purcell, E. K.; Seymour, J. P.; Yandamuri, S.; Kipke, D. R.

    2009-08-01

    In the published article, an error was made in figure 5. Specifically, the three-month, NSC-seeded image is a duplicate of the six-week image, and the one-day, probe alone image is a duplicate of the three-month image. The corrected figure is reproduced below. Figure 5 Figure 5. Glial encapsulation of each probe condition over the 3 month time course. Ox-42 labeled microglia and GFAP labeled astrocytes are shown. Images are taken from probes implanted in the same animal at each time point. NSC seeding was associated with reduced non-neuronal density at 1 day post-implantation in comparison to alginate coated probes and at the 1 week time point in comparison to untreated probes (P < 0.001). Glial activation is at its overall peak 1 week after insertion. A thin encapsulation layer surrounds probes at the 6 week and 3 month time points, with NSC-seeded probes having the greatest surrounding non-neuronal density P < 0.001). Interestingly, microglia appeared to have a ramified, or `surveilling', morphology surrounding a neural stem cell-alginate probe initially, whereas activated cells with an amoeboid structure were found near an alginate probe in the same hemisphere of one animal (left panels).

  15. Receptors for VIP and PACAP in guinea pig cerebral cortex: effects on cyclic AMP synthesis and characterization by 125I-VIP binding.

    PubMed

    Zawilska, Jolanta B; Dejda, Agnieszka; Niewiadomski, Pawel; Gozes, Illana; Nowak, Jerzy Z

    2005-01-01

    Receptors for vasoactive intestinal peptide (VIP) and pituitary adenylate cyclase-activating polypeptide (PACAP) in guinea pig cerebral cortex were characterized by (1) radioreceptor binding of 125I-labeled VIP (human/rat/porcine), and (2) cyclic AMP (cAMP) formation. Saturation analysis of 125I-VIP binding to membranes of guinea pig cerebral cortex resulted in a linear Scatchard plot, suggesting the presence of a single class of high-affinity receptor-binding sites, with a Kd of 0.63 nM and a B(max) of 77 fmol/mg protein. Various peptides from the PACAP/VIP/secretin family displaced the specific binding of 125I-VIP to guinea pig cerebrum with the relative rank order of potency: chicken VIP (cVIP) > or = PACAP38 approximately PACAP27 approximately guinea pig VIP (gpVIP) > or = mammalian (human/rat/porcine) VIP (mVIP) > peptide histidine-methionine (PHM) > peptide histidine-isoleucine (PHI) > secretin. Analysis of the competition curves revealed displacement of 125I-VIP from high- and lower-affinity binding sites, with IC50 values in the picomolar and the nanomolar range, respectively. About 70% of the specific 125I-VIP-binding sites in guinea pig cerebral cortex were sensitive to Gpp(NH)p, a nonhydrolyzable analog of GTP. Pituitary adenylate cyclase-activating polypeptide 38 (PACAP38), PACAP27, cVIP, gpVIP, mVIP, PHM, and PHI stimulated cAMP production in [3H]adenine-prelabeled slices of guinea pig cerebral cortex in a concentration-dependent manner. Of the tested peptides, the most effective were PACAP38 and PACAP27, which at a 1 microM concentration produced a 17- to 19-fold rise in cAMP synthesis, increasing the nucleotide production to approx 11% conversion above the control value. The three forms of VIP (cVIP, mVIP, and gpVIP) at the highest concentration used, i.e., 3 microM, produced net increases in cAMP production in the range of 8-9% conversion, whereas 5 microM PHM and PHI, by, respectively, 6.7% and 4.9% conversion. It is concluded that cerebral cortex

  16. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    PubMed

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p < .0001), clinician (p < .0001), and their interaction (p < .0001). The Tukey's multiple comparison test showed significant differences in RFA for the clinician group I/II (p = .015) and highly significant (p < .0001) between I/III and II/III. The P-implants presented (for I, II, and III) mean ISQ values 31.25/49.18/68.17 and the T-implants showed higher ISQ values, 70.15/62.08/68.98, respectively. Clinicians I and II did not show extreme differences for T-implants (p = .016). In contrast, clinician III achieved high ISQ values using P- and T-implants following the exact surgical protocol based on the manufacturer guidelines. T-implants

  17. Sino-implant (II) - a levonorgestrel-releasing two-rod implant: systematic review of the randomized controlled trials

    PubMed Central

    Steiner, Markus J.; Lopez, Laureen M.; Grimes, David A.; Cheng, Linan; Shelton, Jim; Trussell, James; Farley, Timothy M.M.; Dorflinger, Laneta

    2013-01-01

    Background Sino-implant (II) is a subdermal contraceptive implant manufactured in China. This two-rod levonorgestrel-releasing implant has the same amount of active ingredient (150 mg levonorgestrel) and mechanism of action as the widely available contraceptive implant Jadelle. We examined randomized controlled trials of Sino-implant (II) for effectiveness and side effects. Study design We searched electronic databases for studies of Sino-implant (II), and then restricted our review to randomized controlled trials. The primary outcome of this review was pregnancy. Results Four randomized trials with a total of 15,943 women assigned to Sino-implant (II) had first-year probabilities of pregnancy ranging from 0.0% to 0.1%. Cumulative probabilities of pregnancy during the four years of the product's approved duration of use were 0.9% and 1.06% in the two trials that presented date for four-year use. Five-year cumulative probabilities of pregnancy ranged from 0.7% to 2.1%. In one trial, the cumulative probability of pregnancy more than doubled during the fifth year (from 0.9% to 2.1%), which may be why the implant is approved for four years of use in China. Five-year cumulative probabilities of discontinuation due to menstrual problems ranged from 12.5% to 15.5% for Sino-implant (II). Conclusions Sino-implant (II) is one of the most effective contraceptives available today. These available clinical data, combined with independent laboratory testing, and the knowledge that 7 million women have used this method since 1994, support the safety and effectiveness of Sino-implant (II). The lower cost of Sino-implant (II) compared with other subdermal implants could improve access to implants in resource-constrained settings. PMID:20159174

  18. JcTI-I: a novel trypsin inhibitor from Jatropha curcas seed cake with potential for bacterial infection treatment.

    PubMed

    Costa, Helen P S; Oliveira, Jose T A; Sousa, Daniele O B; Morais, Janne K S; Moreno, Frederico B; Monteiro-Moreira, Ana Cristina O; Viegas, Ricardo A; Vasconcelos, Ilka M

    2014-01-01

    Jatropha curcas seed cake is a low-value by-product resulting from biodiesel production. The seed cake is highly toxic, but it has great potential for biotechnology applications as it is a repository of biomolecules that could be important in agriculture, medicine, and industry. To explore this potential, a novel trypsin inhibitor called JcTI-I was purified by fractionation of the crude extract with trichloroacetic acid (2.5%, v/v) followed by affinity chromatography (Trypsin-Sepharose 4B) and molecular exclusion (Sephacryl S-200). Non-reducing sodium dodecyl sulfate-polyacrylamide gel electrophoresis and gel filtration showed that JcTI-I has approximately 20.0~kDa. Mass spectrometry analysis revealed that the intact molecular mass of JcTI-I is 10.252~kDa. Moreover, JcTI-I is a glycoprotein with 6.4% (m/m) carbohydrates, pI of 6.6, N-terminal sequence similarity around 60% to plant albumins and high stability to heat, pH, and salinity. JcTI-I presented antibacterial activity against the human pathogenic bacteria Salmonella enterica subspecies enterica serovar choleraesuis and Staphylococcus aureus, with minimum inhibitory concentration less than 5~μg/mL. Furthermore, JcTI-I did have inhibitory activity against the serine proteases from the tested bacteria. Otherwise, no hemolytic activity of human erythrocytes and signs of acute toxicity to mice were observed for JcTI-I. The results demonstrate the benefits of J. curcas seed cake as a source of trypsin inhibitor with potential for biotechnological application as a new antimicrobial agent against human pathogenic bacteria.

  19. JcTI-I: a novel trypsin inhibitor from Jatropha curcas seed cake with potential for bacterial infection treatment

    PubMed Central

    Costa, Helen P. S.; Oliveira, Jose T. A.; Sousa, Daniele O. B.; Morais, Janne K. S.; Moreno, Frederico B.; Monteiro-Moreira, Ana Cristina O.; Viegas, Ricardo A.; Vasconcelos, Ilka M.

    2014-01-01

    Jatropha curcas seed cake is a low-value by-product resulting from biodiesel production. The seed cake is highly toxic, but it has great potential for biotechnology applications as it is a repository of biomolecules that could be important in agriculture, medicine, and industry. To explore this potential, a novel trypsin inhibitor called JcTI-I was purified by fractionation of the crude extract with trichloroacetic acid (2.5%, v/v) followed by affinity chromatography (Trypsin-Sepharose 4B) and molecular exclusion (Sephacryl S-200). Non-reducing sodium dodecyl sulfate-polyacrylamide gel electrophoresis and gel filtration showed that JcTI-I has approximately 20.0~kDa. Mass spectrometry analysis revealed that the intact molecular mass of JcTI-I is 10.252~kDa. Moreover, JcTI-I is a glycoprotein with 6.4% (m/m) carbohydrates, pI of 6.6, N-terminal sequence similarity around 60% to plant albumins and high stability to heat, pH, and salinity. JcTI-I presented antibacterial activity against the human pathogenic bacteria Salmonella enterica subspecies enterica serovar choleraesuis and Staphylococcus aureus, with minimum inhibitory concentration less than 5~μg/mL. Furthermore, JcTI-I did have inhibitory activity against the serine proteases from the tested bacteria. Otherwise, no hemolytic activity of human erythrocytes and signs of acute toxicity to mice were observed for JcTI-I. The results demonstrate the benefits of J. curcas seed cake as a source of trypsin inhibitor with potential for biotechnological application as a new antimicrobial agent against human pathogenic bacteria. PMID:24523715

  20. Demonstration of a forward iterative method to reconstruct brachytherapy seed configurations from x-ray projections

    NASA Astrophysics Data System (ADS)

    Murphy, Martin J.; Todor, Dorin A.

    2005-06-01

    By monitoring brachytherapy seed placement and determining the actual configuration of the seeds in vivo, one can optimize the treatment plan during the process of implantation. Two or more radiographic images from different viewpoints can in principle allow one to reconstruct the configuration of implanted seeds uniquely. However, the reconstruction problem is complicated by several factors: (1) the seeds can overlap and cluster in the images; (2) the images can have distortion that varies with viewpoint when a C-arm fluoroscope is used; (3) there can be uncertainty in the imaging viewpoints; (4) the angular separation of the imaging viewpoints can be small owing to physical space constraints; (5) there can be inconsistency in the number of seeds detected in the images; and (6) the patient can move while being imaged. We propose and conceptually demonstrate a novel reconstruction method that handles all of these complications and uncertainties in a unified process. The method represents the three-dimensional seed and camera configurations as parametrized models that are adjusted iteratively to conform to the observed radiographic images. The morphed model seed configuration that best reproduces the appearance of the seeds in the radiographs is the best estimate of the actual seed configuration. All of the information needed to establish both the seed configuration and the camera model is derived from the seed images without resort to external calibration fixtures. Furthermore, by comparing overall image content rather than individual seed coordinates, the process avoids the need to establish correspondence between seed identities in the several images. The method has been shown to work robustly in simulation tests that simultaneously allow for unknown individual seed positions, uncertainties in the imaging viewpoints and variable image distortion.

  1. Contagious seed dispersal beneath heterospecific fruiting trees and its consequences.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwit, Charles; Levey, Douglas, J.; Greenberg, Cathyrn, H.

    2004-05-03

    Kwit, Charles, D.J. Levey and Cathryn H. Greenberg. 2004. Contagious seed dispersal beneath heterospecific fruiting trees and its consequences. Oikos. 107:303-308 A n hypothesized advantage of seed dispersal is avoidance of high per capita mortality (i.e. density-dependent mortality) associated with dense populations of seeds and seedlings beneath parent trees. This hypothesis, inherent in nearly all seed dispersal studies, assumes that density effects are species-specific. Yet because many tree species exhibit overlapping fruiting phenologies and share dispersers, seeds may be deposited preferentially under synchronously fruiting heterospecific trees, another location where they may be particularly vulnerable to mortality, in this case bymore » generalist seed predators. We demonstrate that frugivores disperse higher densities of Cornus florida seeds under fruiting (female) I lex opaca trees than under non-fruiting (male) I lex trees in temperate hardwood forest settings in South Carolina, U SA . To determine if density of Cornus and/or I lex seeds influences survivorship of dispersed Cornus seeds, we followed the fates of experimentally dispersed Cornus seeds in neighborhoods of differing, manipulated background densities of Cornus and I lex seeds. We found that the probability of predation on dispersed Cornus seeds was a function of both Cornus and I lex background seed densities. H igher densities of I lex seeds negatively affected Cornus seed survivorship, and this was particularly evident as background densities of dispersed Cornus seeds increased. These results illustrate the importance of viewing seed dispersal and predation in a community context, as the pattern and intensity of density-dependent mortality may not be solely a function of conspecific densities.« less

  2. The possible protective role of pumpkin seed oil in an animal model of acid aspiration pneumonia: Light and electron microscopic study.

    PubMed

    Omar, Nesreen Moustafa; Sarhan, Nahla Reda

    2017-03-01

    Aspiration pneumonitis is a common problem occurring in many clinical disorders. Pumpkin seed oil (PO) is a rich source of antioxidants. This work aimed to assess the effect of PO on the lung histopathological changes induced by acid aspiration. Forty male albino rats assigned to four groups were used. Rats of control group were instilled intratracheally with normal saline 2mL/kg. HCL group instilled with 2mL/kg of HCL 0.1N, pH 1.25. PO group received pumpkin seed oil (PO) orally (∼1375mg/kgbw/day) for 7days. HCL+PO group instilled with 2mL/kg of HCL 0.1N, pH 1.25 and received PO at the same dose of PO group. Lung tissue samples were processed for light, electron microscopic and immunohistochemical study using anti inducible NO synthase (iNOS). The lung of HCL group demonstrated thickened interalveolar septa, inflammatory cell infiltration and significant increase in the area percent of collagenous fibers and immune expression of iNOS. Ultra structurally, disrupted alveolocapillay membrane, degenerated type II pneumocytes and plentiful alveolar macrophages were evident. PO administration partially attenuated these histological and ultra structural alterations and reduced iNOS immune-expression in lung tissue. In conclusion, PO has a protective effect against HCL aspiration lung injury most probably through its antioxidant activity. Copyright © 2017 Elsevier GmbH. All rights reserved.

  3. Time Course of Peri-Implant Bone Regeneration around Loaded and Unloaded Implants in a Rat Model

    PubMed Central

    Jariwala, Shailly H.; Wee, Hwabok; Roush, Evan P.; Whitcomb, Tiffany L.; Murter, Christopher; Kozlansky, Gery; Lakhtakia, Akhlesh; Kunselman, Allen R.; Donahue, Henry J.; Armstrong, April D.; Lewis, Gregory S.

    2018-01-01

    The time-course of cancellous bone regeneration surrounding mechanically loaded implants affects implant fixation, and is relevant to determining optimal rehabilitation protocols following orthopaedic surgeries. We investigated the influence of controlled mechanical loading of titanium-coated polyether-ether ketone (PEEK) implants on osseointegration using time-lapsed, non-invasive, in vivo micro-computed tomography (micro-CT) scans. Implants were inserted into proximal tibial metaphyses of both limbs of eight female Sprague-Dawley rats. External cyclic loading (60 μm or 100 μm displacement, 1 Hz, 60 seconds) was applied every other day for 14 days to one implant in each rat, while implants in contralateral limbs served as the unloaded controls. Hind limbs were imaged with high-resolution micro-CT (12.5 μm voxel size) at 2, 5, 9, and 12 days post-surgery. Trabecular changes over time were detected by 3D image registration allowing for measurements of bone-formation rate (BFR) and bone-resorption rate (BRR). At day 9, mean %BV/TV for loaded and unloaded limbs were 35.5 ± 10.0 % and 37.2 ± 10.0 %, respectively, and demonstrated significant increases in bone volume compared to day 2. BRR increased significantly after day 9. No significant differences between bone volumes, BFR, and BRR were detected due to implant loading. Although not reaching significance (p = 0.16), an average 119 % increase in pull-out strength was measured in the loaded implants. PMID:27381807

  4. Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: A pilot ex vivo study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehrmohammadi, Mohammad; Kinnick, Randall R.; Fatemi, Mostafa, E-mail: fatemi.mostafa@mayo.edu

    2014-09-15

    Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped withmore » a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that

  5. Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: A pilot ex vivo study

    PubMed Central

    Mehrmohammadi, Mohammad; Alizad, Azra; Kinnick, Randall R.; Davis, Brian J.; Fatemi, Mostafa

    2014-01-01

    Purpose: Effective permanent prostate brachytherapy (PPB) requires precise placement of radioactive seeds in and around the prostate. The impetus for this research is to examine a new ultrasound-based imaging modality, vibro-acoustography (VA), which may serve to provide a high rate of PPB seed detection while also effecting enhanced prostate imaging. The authors investigate the ability of VA, implemented on a clinical ultrasound (US) scanner and equipped with a quasi-2D (Q2D) array US transducer, to detect and localize PPB seeds in excised prostate specimens. Methods: Nonradioactive brachytherapy seeds were implanted into four excised cadaver prostates. A clinical US scanner equipped with a Q2D array US transducer was customized to acquire both US and C-scan VA images at various depths. The VA images were then used to detect and localize the implanted seeds in prostate tissue. To validate the VA results, computed tomography (CT) images of the same tissue samples were obtained to serve as the reference by which to evaluate the performance of VA in PPB seed detection. Results: The results indicate that VA is capable of accurately identifying the presence and distribution of PPB seeds with a high imaging contrast. Moreover, a large ratio of the PPB seeds implanted into prostate tissue samples could be detected through acquired VA images. Using CT-based seed identification as the standard, VA was capable of detecting 74%–92% of the implanted seeds. Additionally, the angular independency of VA in detecting PPB seeds was demonstrated through a well-controlled phantom experiment. Conclusions: Q2DVA detected a substantial portion of the seeds by using a 2D array US transducer in excised prostate tissue specimens. While VA has inherent advantages associated with conventional US imaging, it has the additional advantage of permitting detection of PPB seeds independent of their orientation. These results suggest the potential of VA as a method for PPB imaging that

  6. Drug Delivery: Enabling Technology for Drug Discovery and Development. iPRECIO® Micro Infusion Pump: Programmable, Refillable, and Implantable

    PubMed Central

    Tan, Tsung; Watts, Stephanie W.; Davis, Robert Patrick

    2011-01-01

    Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic, and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO® use in Japan, United States, and Europe with iPRECIO® as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO® applications are described in detail with references to the original work where the implantable, refillable, and programmable benefits are demonstrated with their different end-points. PMID:21863140

  7. SU-E-T-55: Biological Equivalent Dose (BED) Comparison Between Permanent Interstitial Brachytherapy and Conventional External Beam Radiotherapy for Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, X; Rahimian, J; Cosmatos, H

    2014-06-01

    Purpose: The goal of this research is to calculate and compare the Biological Equivalent Dose (BED) between permanent prostate Iodine-125 implant brachytherapy as monotherapy with the BED of conventional external beam radiation therapy (EBRT). Methods: A retrospective study of 605 patients treated with Iodine-125 seed implant was performed in which physician A treated 274 patients and physician B treated 331 patients. All the Brachytherapy treatment plans were created using VariSeed 8 planning system. The Iodine-125 seed source activities and loading patterns varied slightly between the two physicians. The prescription dose is 145 Gy to PTV for each patient. The BEDmore » and Tumor Control Probability (TCP) were calculated based on the TG 137 formulas. The BED for conventional EBRT of the prostate given in our institution in 2Gy per fraction for 38 fractions was calculated and compared. Results: Physician A treated 274 patients with an average BED of 123.92±0.87 Gy and an average TCP of 99.20%; Physician B treated 331 patients with an average BED of 124.87±1.12 Gy and an average TCP of 99.30%. There are no statistically significant differences (T-Test) between the BED and TCP values calculated for these two group patients.The BED of the patients undergoing conventional EBRT is calculated to be 126.92Gy. The BED of the patients treated with permanent implant brachytherapy and EBRT are comparable. Our BED and TCP values are higher than the reported values by TG 137 due to higher Iodine-125 seed activity used in our institution. Conclusion: We calculated the BED,a surrogate of the biological response to a permanent prostate brachytherapy using TG 137 formulas and recommendation. The TCP of better than 99% is calculated for these patients. A clinical outcome study of these patients correlating the BED and TCP values with PSA and Gleason Levels as well as patient survival is warranted.« less

  8. Myrmecochory and short-term seed fate in Rhamnus alaternus: Ant species and seed characteristics

    NASA Astrophysics Data System (ADS)

    Bas, J. M.; Oliveras, J.; Gómez, C.

    2009-05-01

    Benefits conferred on plants in ant-mediated seed dispersal mutualisms (myrmecochory) depend on the fate of transported seeds. We studied the effects of elaiosome presence, seed size and seed treatment (with and without passage through a bird's digestive tract) on short-term seed fate in Rhamnus alaternus. In our study, we define short-term seed, or initial, seed fate, as the location where ants release the seeds after ant contact with it. The elaiosomes had the most influence on short-term fate, i.e. whether or not seeds were transported to the nest. The workers usually transported big seeds more often than small ones, but small ants did not transport large seeds. Effect of seed size on transport depended on the ant species and on the treatment of the seed (manual extraction simulating a direct fall from the parent plant vs. bird deposition corresponding to preliminary primary dispersal). Probability of removal of elaiosome-bearing seeds to the nest by Aphaenogaster senilis increased with increasing seed weight.

  9. 21 CFR 14.125 - Procedures of TEPRSSC.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Procedures of TEPRSSC. 14.125 Section 14.125 Food...) The agenda and other material to be considered at any meeting will be sent to members whenever... members are present from each group specified in 21 U.S.C. 360kk(f)(1)(A) and in § 14.127(a), i.e...

  10. 21 CFR 14.125 - Procedures of TEPRSSC.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Procedures of TEPRSSC. 14.125 Section 14.125 Food...) The agenda and other material to be considered at any meeting will be sent to members whenever... members are present from each group specified in 21 U.S.C. 360kk(f)(1)(A) and in § 14.127(a), i.e...

  11. In vivo magnetic resonance imaging of type I collagen scaffold in rat: improving visualization of bladder and subcutaneous implants.

    PubMed

    Sun, Yi; Geutjes, Paul; Oosterwijk, Egbert; Heerschap, Arend

    2014-12-01

    Noninvasive monitoring of implanted scaffolds is important to understand their behavior and role in tissue engineering, in particular to follow their degradation and interaction with host tissue. Magnetic resonance imaging (MRI) is well suited for this goal, but its application is often hampered by the low contrast of scaffolds that are prepared from biomaterials such as type I collagen. The aim of this study was to test iron oxide particles incorporation in improving their MRI contrasts, and to follow their degradation and tissue interactions. Scaffolds with and without iron oxide particles were implanted either subcutaneously or on the bladder of rats. At predetermined time points, in vivo MRI were obtained and tissues were then harvested for histology analysis and transmission electron microscopy. The result showed that the incorporation of iron oxide particles improved MRI contrast of the implants, providing information on their location, shapes, and degradation. Second, the host tissue reaction to the type I collagen implants could be observed in both MRI and histology. Finally, MRI also revealed that the degradation and host tissue reaction of iron particles-loaded scaffolds differed between subcutaneous and bladder implantation, which was substantiated by histology.

  12. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, T; Wang, J; Frank, S

    Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGRmore » sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR

  13. Production of specific antisera for radioimmunoassay of human luteinizing hormone (LH) in the presence of human chorionic gonadotropin (hCG). [/sup 125/I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thorell, J.I.; Jeppsson, S.; Holmstrom, B.

    1976-09-01

    A specific radioimmunoassay for LH, which measures plasma LH in the presence of human chorionic gonadotropin (hCG) is described. Rabbits were immunized with highly purified native LH. One of the antisera with a difference in its reactivity against LH and hCG was further purified by affinity chromatography on a column with hCG coupled to Sepharose 4B. The adsorbed antiserum and /sup 125/I-LH was used in a double antibody assay. The LH standard (MRC/68/40) efficiently inhibited the binding of /sup 125/I-LH, and the standard curve showed a sensitivity of 0.5 ng/ml in the sample. hCG up to 10,000 ng/ml did notmore » inhibit the binding of /sup 125/I-LH. The plasma level of LH in pregnant women in the first trimester was low (1.3 +- 0.1 ng/ml). When LH was measured in fertile or menopausal women with or without stimulation with LH/FSH releasing hormone (LH-RH)/sup x/ the results agreed to those found with our conventional LH-assay based on antiserum against hCG.« less

  14. Implantable cardiac arrhythmia devices--part I: pacemakers.

    PubMed

    Kusumoto, Fred M; Goldschlager, Nora

    2006-05-01

    Implantable cardiac devices have become firmly entrenched as important therapeutic tools for a variety of cardiac conditions. The first part of this two-part review will discuss the contemporary use and follow-up of pacemakers, while the second part will address the use of implantable cardioverter defibrillators and implantable loop recorders. Pacemakers are the only available treatment for symptomatic bradycardia not due to reversible causes. Large randomized studies have demonstrated a small but statistically significant reduction in atrial fibrillation associated with pacing modes that maintain atrioventricular synchrony. In contrast, pacing mode appears to have a less dramatic effect in patients with atrioventricular block. Cardiac resynchronization with specialized left ventricular leads has been shown to reduce symptoms and improve survival in patients with symptomatic heart failure, systolic dysfunction, and widened QRS complexes. For all patients, careful follow-up is necessary to ensure optimal therapeutic benefit of pacing systems.

  15. Antibacterial Activity of Pharbitin, Isolated from the Seeds of Pharbitis nil, against Various Plant Pathogenic Bacteria.

    PubMed

    Nguyen, Hoa Thi; Yu, Nan Hee; Park, Ae Ran; Park, Hae Woong; Kim, In Seon; Kim, Jin-Cheol

    2017-10-28

    This study aimed to isolate and characterize antibacterial metabolites from Pharbitis nil seeds and investigate their antibacterial activity against various plant pathogenic bacteria. The methanol extract of P. nil seeds showed the strongest activity against Xanthomonas arboricola pv. pruni (Xap) with a minimum inhibition concentration (MIC) value of 250 μg/ml. Among the three solvent layers obtained from the methanol extract of P. nil seeds, only the butanol layer displayed the activity with an MIC value of 125 μg/ml against Xap. An antibacterial fraction was obtained from P. nil seeds by repeated column chromatography and identified as pharbitin, a crude resin glycoside, by instrumental analysis. The antibacterial activity of pharbitin was tested in vitro against 14 phytopathogenic bacteria, and it was found to inhibit Ralstonia solanacearum and four Xanthomonas species. The minimum inhibitory concentration values against the five bacteria were 125-500 μg/ml for the n-butanol layer and 31.25-125 μg/ml for pharbitin. In a detached peach leaf assay, it effectively suppressed the development of bacterial leaf spot, with a control value of 87.5% at 500 μg/ml. In addition, pharbitin strongly reduced the development of bacterial wilt on tomato seedlings by 97.4% at 250 μg/ml, 7 days after inoculation. These findings suggest that the crude extract of P. nil seeds can be used as an alternative biopesticide for the control of plant diseases caused by R. solanacearum and Xanthomonas spp. This is the first report on the antibacterial activity of pharbitin against phytopathogenic bacteria.

  16. Method of electroplating a conversion electron emitting source on implant

    DOEpatents

    Srivastava, Suresh C [Setauket, NY; Gonzales, Gilbert R [New York, NY; Adzic, Radoslav [East Setauket, NY; Meinken, George E [Middle Island, NY

    2012-02-14

    Methods for preparing an implant coated with a conversion electron emitting source (CEES) are disclosed. The typical method includes cleaning the surface of the implant; placing the implant in an activating solution comprising hydrochloric acid to activate the surface; reducing the surface by H.sub.2 evolution in H.sub.2SO.sub.4 solution; and placing the implant in an electroplating solution that includes ions of the CEES, HCl, H.sub.2SO.sub.4, and resorcinol, gelatin, or a combination thereof. Alternatively, before tin plating, a seed layer is formed on the surface. The electroplated CEES coating can be further protected and stabilized by annealing in a heated oven, by passivation, or by being covered with a protective film. The invention also relates to a holding device for holding an implant, wherein the device selectively prevents electrodeposition on the portions of the implant contacting the device.

  17. Quantitative autoradiography of the binding sites for ( sup 125 I) iodoglyburide, a novel high-affinity ligand for ATP-sensitive potassium channels in rat brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gehlert, D.R.; Gackenheimer, S.L.; Mais, D.E.

    1991-05-01

    We have developed a high specific activity ligand for localization of ATP-sensitive potassium channels in the brain. When brain sections were incubated with ({sup 125}I)iodoglyburide (N-(2-((((cyclohexylamino)carbonyl)amino)sulfonyl)ethyl)-5-{sup 125}I-2- methoxybenzamide), the ligand bound to a single site with a KD of 495 pM and a maximum binding site density of 176 fmol/mg of tissue. Glyburide was the most potent inhibitor of specific ({sup 125}I)iodoglyburide binding to rat forebrain sections whereas iodoglyburide and glipizide were slightly less potent. The binding was also sensitive to ATP which completely inhibited binding at concentrations of 10 mM. Autoradiographic localization of ({sup 125}I)iodoglyburide binding indicated a broadmore » distribution of the ATP-sensitive potassium channel in the brain. The highest levels of binding were seen in the globus pallidus and ventral pallidum followed by the septohippocampal nucleus, anterior pituitary, the CA2 and CA3 region of the hippocampus, ventral pallidum, the molecular layer of the cerebellum and substantia nigra zona reticulata. The hilus and dorsal subiculum of the hippocampus, molecular layer of the dentate gyrus, cerebral cortex, lateral olfactory tract nucleus, olfactory tubercle and the zona incerta contained relatively high levels of binding. A lower level of binding (approximately 3- to 4-fold) was found throughout the remainder of the brain. These results indicate that the ATP-sensitive potassium channel has a broad presence in the rat brain and that a few select brain regions are enriched in this subtype of neuronal potassium channels.« less

  18. Alternative to radical surgery for cancer of the prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathes, G.L.; Page, R.C.

    1978-08-01

    We have used the technique of retropubic implantation of /sup 125/I seeds, as introduced by Whitmore and associates in 1972, in 12 selected patients with prostatic cancer. Morbidity has been minimal, and the tumor has been effectively controlled. This technique delivers more radiation and has fewer side effects than external cobalt irradiation, and it should be offered to the patient as an effective alternative to radical prostatectomy. It is best suited for patients with stage A, stage B, or small stage C lesions who have negative bone scans. Edema of the penis follows the lymphadenectomy but gradually subsides.

  19. Selective inhibition by dactinomycin of NANC sensory bronchoconstriction and [125I]NKA binding due to NK-2 receptor antagonism.

    PubMed

    Lou, Y P; Delay-Goyet, P; Lundberg, J M

    1992-03-01

    In the present study, dactinomycin (10(-5) M) inhibited the non-adrenergic, non-cholinergic bronchoconstriction upon antidromic vagal nerve stimulation (1 Hz for 1 min) in the isolated perfused guinea-pig lung by 84%. The release of calcitonin gene-related peptide was unchanged, however, suggesting a postjunctional action. Dactinomycin (10(-5), 5 x 10(-5) M) also reduced non-adrenergic non-cholinergic bronchial contractions (maximally by 75%) induced by electrical field stimulation or capsaicin, while the cholinergic component and non-adrenergic non-cholinergic relaxation remained intact. The neurokinin-2 receptor antagonist L-659,877 (10(-6) M) had a similar effect as dactinomycin, inhibiting the non-adrenergic non-cholinergic bronchial contractions by 69%, while the neurokinin-1 receptor antagonist CP-96,345 (10(-6) M) had no effect. The bronchoconstriction evoked by neurokinin A, the selective neurokinin-2 receptor agonist Nle10neurokinin A (4-10) and capsaicin was markedly inhibited by dactinomycin while the contraction induced by substance P (SP), the selective neurokinin-1 receptor agonist Sar9Met(O2)11SP, endothelin-1 and acetylcholine was not affected. In autoradiographic experiments on guinea-pig lung, [125I]neurokinin A-labelled sections showed dense binding in the bronchial smooth muscle layer. Dactinomycin inhibited the specific binding of [125I]neurokinin A in a concentration-dependent manner (IC50 = 6.3 x 10(-6) M) and 66% of [125I]neurokinin A total binding was inhibited by 10(-4) M dactinomycin. In the rat colon, [125I]neurokinin A binding to neurokinin-2 sites on circular smooth muscle was inhibited by dactinomycin with an IC50 value of 7.9 x 10(-6) M. Dactinomycin failed to reduce increased nerve-evoked contractions or those caused by Nle10neurokinin A (4-10) per se in the rat vas deferens, which are considered to be mediated by neurokinin-2 receptor activation. In the rat portal vein, dactinomycin did not influence the contractions caused by the

  20. Pre-dispersal predation effect on seed packaging strategies and seed viability.

    PubMed

    DeSoto, Lucía; Tutor, David; Torices, Rubén; Rodríguez-Echeverría, Susana; Nabais, Cristina

    2016-01-01

    An increased understanding of intraspecific seed packaging (i.e. seed size/number strategy) variation across different environments may improve current knowledge of the ecological forces that drive seed evolution in plants. In particular, pre-dispersal seed predation may influence seed packaging strategies, triggering a reduction of the resources allocated to undamaged seeds within the preyed fruits. Assessing plant reactions to pre-dispersal seed predation is crucial to a better understanding of predation effects, but the response of plants to arthropod attacks remains unexplored. We have assessed the effect of cone predation on the size and viability of undamaged seeds in populations of Juniperus thurifera with contrasting seed packaging strategies, namely, North African populations with single-large-seeded cones and South European populations with multi-small-seeded cones. Our results show that the incidence of predation was lower on the single-large-seeded African cones than on the multi-small-seeded European ones. Seeds from non-preyed cones were also larger and had a higher germination success than uneaten seeds from preyed cones, but only in populations with multi-seeded cones and in cones attacked by Trisetacus sp., suggesting a differential plastic response to predation. It is possible that pre-dispersal seed predation has been a strong selective pressure in European populations with high cone predation rates, being a process which maintains multi-small-seeded cones and empty seeds as a strategy to save some seeds from predation. Conversely, pre-dispersal predation might not have a strong effect in the African populations with single-large-seeded cones characterized by seed germination and filling rates higher than those in the European populations. Our results indicate that differences in pre-dispersal seed predators and predation levels may affect both selection on and intraspecific variation in seed packaging.

  1. A simple ion implanter for material modifications in agriculture and gemmology

    NASA Astrophysics Data System (ADS)

    Singkarat, S.; Wijaikhum, A.; Suwannakachorn, D.; Tippawan, U.; Intarasiri, S.; Bootkul, D.; Phanchaisri, B.; Techarung, J.; Rhodes, M. W.; Suwankosum, R.; Rattanarin, S.; Yu, L. D.

    2015-12-01

    In our efforts in developing ion beam technology for novel applications in biology and gemmology, an economic simple compact ion implanter especially for the purpose was constructed. The designing of the machine was aimed at providing our users with a simple, economic, user friendly, convenient and easily operateable ion implanter for ion implantation of biological living materials and gemstones for biotechnological applications and modification of gemstones, which would eventually contribute to the national agriculture, biomedicine and gem-industry developments. The machine was in a vertical setup so that the samples could be placed horizontally and even without fixing; in a non-mass-analyzing ion implanter style using mixed molecular and atomic nitrogen (N) ions so that material modifications could be more effective; equipped with a focusing/defocusing lens and an X-Y beam scanner so that a broad beam could be possible; and also equipped with a relatively small target chamber so that living biological samples could survive from the vacuum period during ion implantation. To save equipment materials and costs, most of the components of the machine were taken from decommissioned ion beam facilities. The maximum accelerating voltage of the accelerator was 100 kV, ideally necessary for crop mutation induction and gem modification by ion beams from our experience. N-ion implantation of local rice seeds and cut gemstones was carried out. Various phenotype changes of grown rice from the ion-implanted seeds and improvements in gemmological quality of the ion-bombarded gemstones were observed. The success in development of such a low-cost and simple-structured ion implanter provides developing countries with a model of utilizing our limited resources to develop novel accelerator-based technologies and applications.

  2. Effect of cell-seeded hydroxyapatite scaffolds on rabbit radius bone regeneration.

    PubMed

    Rathbone, C R; Guda, T; Singleton, B M; Oh, D S; Appleford, M R; Ong, J L; Wenke, J C

    2014-05-01

    Highly porous hydroxyapatite (HA) scaffolds were developed as bone graft substitutes using a template coating process, characterized, and seeded with bone marrow-derived mesenchymal stem cells (BMSCs). To test the hypothesis that cell-seeded HA scaffolds improve bone regeneration, HA scaffolds without cell seeding (HA-empty), HA scaffolds with 1.5 × 10(4) BMSCs (HA-low), and HA scaffolds with 1.5 × 10(6) BMSCs (HA-high) were implanted in a 10-mm rabbit radius segmental defect model for 4 and 8 weeks. Three different fluorochromes were administered at 2, 4, and 6 weeks after implantation to identify differences in temporal bone growth patterns. It was observed from fluorescence histomorphometry analyses that an increased rate of bone infiltration occurred from 0 to 2 weeks (p < 0.05) of implantation for the HA-high group (2.9 ± 0.5 mm) as compared with HA-empty (1.8 ± 0.8 mm) and HA-low (1.3 ± 0.2 mm) groups. No significant differences in bone formation within the scaffold or callus formation was observed between all groups after 4 weeks, with a significant increase in bone regenerated for all groups from 4 to 8 weeks (28.4% across groups). Although there was no difference in bone formation within scaffolds, callus formation was significantly higher in HA-empty scaffolds (100.9 ± 14.1 mm(3) ) when compared with HA-low (57.8 ± 7.3 mm(3) ; p ≤ 0.003) and HA-high (69.2 ± 10.4 mm(3) ; p ≤ 0.02) after 8 weeks. These data highlight the need for a better understanding of the parameters critical to the success of cell-seeded HA scaffolds for bone regeneration. Copyright © 2013 Wiley Periodicals, Inc.

  3. Accomplishments of the Oak Ridge National Laboratory Seed Money program

    DOE R&D Accomplishments Database

    1986-09-01

    In 1974, a modest program for funding new, innovative research was initiated at ORNL. It was called the "Seed Money" program and has become part of a larger program, called Exploratory R and D, which is being carried out at all DOE national laboratories. This report highlights 12 accomplishments of the Seed Money Program: nickel aluminide, ion implantation, laser annealing, burn meter, Legionnaires' disease, whole-body radiation counter, the ANFLOW system, genetics and molecular biology, high-voltage equipment, microcalorimeter, positron probe, and atom science. (DLC)

  4. Customized ultra-high-power toric intraocular lens implantation for pellucid marginal degeneration and cataract.

    PubMed

    Luck, Jonathan

    2010-07-01

    I report a case of pellucid marginal degeneration (PMD) with cataract that was successfully treated with implantation of an ultra-high-power customized bitoric AT.Comfort 646TLC intraocular lens (IOL). The preoperative uncorrected distance visual acuity (UDVA) was 6/120 and the corrected distance visual acuity (CDVA), 6/24 with 10.9 diopters (D) of keratometric astigmatism on Scheimpflug imaging. After implantation of an IOL with -0.5 +16.0 x 170, the UDVA was 6/9 with a manifest refraction of +0.25 +1.25 x 150 and the CDVA, 6/6(-1). No surgical complications or postoperative problems occurred, and the patient was very satisfied with the outcome. A longer follow-up is required to confirm this favorable clinical result. The author has no financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Preparation of (125)I-ricin suitable as a probe for the autoradiographic localization of toxin binding sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doebler, J.A.; Mayer, T.W.; Traub, R.K.

    1993-05-13

    The long term objectives of this research are to identify cellular binding sites for ricin and examine its organ distribution in mice following aerosol inhalation exposure. Preliminary studies relating to the synthesis and evaluation of (125 I)-ricin as an autoradiographic probe have been conducted. Non-radioactive (I)-ricin prepared using the Iodogen method was found to be non-toxic both in vivo and in vitro. Lactose was then added to the Iodogen reaction medium to block galactose-binding site associated tyrosines in an attempt to retain toxicity. However, this did not prevent iodination-induced loss of biological potency. We then switched to the lactoperoxidase methodmore » of iodination, which yielded an (I)-ricin preparation with toxicity comparable to that of native toxin.« less

  6. THE USE OF I$sup 125$ LABELED DIIODOFLUORESCEIN IN THE DETECTION OF HUMAN INTRAOCULAR NEOPLASMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goren, S.B.; Newell, E.W.; Brizel, H.E.

    The new method which is described is believed to be superior to the usual method for detection of intraocular tumors using P/sup 32/. Because of the limited penetration of beta rays, the use of P/sup 32/ imposes relatively strict geometric restrictions and its usefulness in posterior-segment tumors is limited. The patient receives a single intravenous injection of 5.0 mu c/kg body weight of diiodofluorescein-I/sup 125/, the specific activity of which is 17 mg/mc. External counting over each closed eye is carried out with a hand scintillation counter 1, 5, 8, and 24 hr after injection. Ocular counts are performed bymore » resting the window of the counter against the closed lids; the cavernous sinus is measured by placing the counter just above the bridge of the nose. ln the 17 patients studied, eyes with neoplasms contained at least 23% more radioactivity after 8 hr than did the healthy eye. Control eyes, not containing neoplasms (idiopathic retinal detachment, retinoschisis, benign nevus, macular degeneration, phthisis bulbi, absolute glaucoma), showed less than a 13% differential. One false negative test was obtained, a patient with a metastatic bronchogenic adenocarcinoma to the choroid; no false positives were seen. Diiodofluorescein labeled with I/sup 131/ has been widely used as a diagnostic aid in suspected intracranial neoplasms. However, since the gamma rays of I/sup 131/ have a half-value layer in tissue of 6.9 cm, it has not been helpful in ocular disease; the gamma rays arising from the cavernous sinus interfere with accurate counting of intraocular radiation. I/sup 125/ decays by a complicated scheme, the most important as far as ocular studies are concerned being soft photons of 27.3 and 35.4 kev energies. It has a half-value layer in tissue of 1.9 to 2.5 cm. Therefore, it is feasible to measure radiation of the posterior globe with only minimal interference from radiation arising in the brain sinuses. Its half-life of 60 days results in a greatly

  7. Comparison of whole body and tissue blood volumes in rainbow trout (Salmo gairdneri) with 125I bovine serum albumin and 51Cr-erythrocyte tracers

    USGS Publications Warehouse

    Gingerich, W.H.; Pityer, R.A.

    1989-01-01

    Total, packed cell and, plasma volume estimates were made for the whole body and selected tissues of rainbow trout by the simultaneous injection of radiolabelled trout erythrocyte (51Cr-RBC) and radioiodinated bovine serum albumin (125I-BSA) tracers. Blood volumes were estimated with both markers separately by the tracer-hematocrit method and as the combination of the 51Cr-RBC packed cell and 125I-BSA plasma volumes. Mean whole body blood volume was significantly less when calculated from the 51Cr-RBC tracer data (3.52±0.78 ml/100 g; ±SD) than when calculated with the 125I-BSA tracer (5.06±0.86 ml/100 g) or as the sum of the two volumes combined (4.49±0.60 ml/100 g). The whole body hematocrit (28±5%), estimated as the quotient of the 51Cr-RBC volume divided by the sum of the 125I-BSA and the 51Cr-RBC volumes, also was significantly less than the dorsal aortic microhematocrit (36±4%). Estimates of total blood volumes in most tissues were significantly smaller when calculated from the51Cr-RBC data than when calculated by the other two methods. Tissue blood volumes were greatest in highly vascularized and well perfused tissues and least in poorly vascularized tissues. The relative degree of vascularization among tissues generally remained the same regardless of whether the red cell or the plasma tracer was used to calculated blood volume. It is not clear whether the expanded plasma volume is the result of the distribution of erythrocyte-poor blood into the secondary circulation or the result of extravascular exchange of plasma proteins.

  8. 49 CFR 571.125 - Standard No. 125; Warning devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 125; Warning devices. 571.125 Section... Motor Vehicle Safety Standards § 571.125 Standard No. 125; Warning devices. S1. Scope. This standard... affixed to both faces of the warning device. Alternatively, a dual purpose orange fluorescent and red...

  9. 49 CFR 571.125 - Standard No. 125; Warning devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Standard No. 125; Warning devices. 571.125 Section... Motor Vehicle Safety Standards § 571.125 Standard No. 125; Warning devices. S1. Scope. This standard... affixed to both faces of the warning device. Alternatively, a dual purpose orange fluorescent and red...

  10. 49 CFR 571.125 - Standard No. 125; Warning devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 125; Warning devices. 571.125 Section... Motor Vehicle Safety Standards § 571.125 Standard No. 125; Warning devices. S1. Scope. This standard... affixed to both faces of the warning device. Alternatively, a dual purpose orange fluorescent and red...

  11. 49 CFR 571.125 - Standard No. 125; Warning devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Standard No. 125; Warning devices. 571.125 Section... Motor Vehicle Safety Standards § 571.125 Standard No. 125; Warning devices. S1. Scope. This standard... affixed to both faces of the warning device. Alternatively, a dual purpose orange fluorescent and red...

  12. 49 CFR 571.125 - Standard No. 125; Warning devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 125; Warning devices. 571.125 Section... Motor Vehicle Safety Standards § 571.125 Standard No. 125; Warning devices. S1. Scope. This standard... affixed to both faces of the warning device. Alternatively, a dual purpose orange fluorescent and red...

  13. Influence of bone marrow-derived mesenchymal stem cells pre-implantation differentiation approach on periodontal regeneration in vivo.

    PubMed

    Cai, Xinjie; Yang, Fang; Yan, Xiangzhen; Yang, Wanxun; Yu, Na; Oortgiesen, Daniel A W; Wang, Yining; Jansen, John A; Walboomers, X Frank

    2015-04-01

    The implantation of bone marrow-derived mesenchymal stem cells (MSCs) has previously been shown successful to achieve periodontal regeneration. However, the preferred pre-implantation differentiation strategy (e.g. maintenance of stemness, osteogenic or chondrogenic induction) to obtain optimal periodontal regeneration is still unknown. This in vivo study explored which differentiation approach is most suitable for periodontal regeneration. Mesenchymal stem cells were obtained from Fischer rats and seeded onto poly(lactic-co-glycolic acid)/poly(ɛ-caprolactone) electrospun scaffolds, and then pre-cultured under different in vitro conditions: (i) retention of multilineage differentiation potential; (ii) osteogenic differentiation approach; and (iii) chondrogenic differentiation approach. Subsequently, the cell-scaffold constructs were implanted into experimental periodontal defects of Fischer rats, with empty scaffolds as controls. After 6 weeks of implantation, histomorphometrical analyses were applied to evaluate the regenerated periodontal tissues. The chondrogenic differentiation approach showed regeneration of alveolar bone and ligament tissues. The retention of multilineage differentiation potential supported only ligament regeneration, while the osteogenic differentiation approach boosted alveolar bone regeneration. Chondrogenic differentiation of MSCs before implantation is a useful strategy for regeneration of alveolar bone and periodontal ligament, in the currently used rat model. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Preparation of graphene on Cu foils by ion implantation with negative carbon clusters

    NASA Astrophysics Data System (ADS)

    Li, Hui; Shang, Yan-Xia; Zhang, Zao-Di; Wang, Ze-Song; Zhang, Rui; Fu, De-Jun

    2015-01-01

    We report on few-layer graphene synthesized on Cu foils by ion implantation using negative carbon cluster ions, followed by annealing at 950 °C in vacuum. Raman spectroscopy reveals IG/I2D values varying from 1.55 to 2.38 depending on energy and dose of the cluster ions, indicating formation of multilayer graphene. The measurements show that the samples with more graphene layers have fewer defects. This is interpreted by graphene growth seeded by the first layers formed via outward diffusion of C from the Cu foil, though nonlinear damage and smoothing effects also play a role. Cluster ion implantation overcomes the solubility limit of carbon in Cu, providing a technique for multilayer graphene synthesis. Project supported by the National Natural Science Foundation of China (Grant Nos. 11105100, 11205116, and 11375135) and the State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, China (Grant No. AWJ-M13-03).

  15. Radioimmunoanalysis of delta-9-THC in blood by means of an /sup 125/I tracer. [Delta-9-Tetrahydrocannabinol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, S.M.; McBay, A.J.; Reisner, H.M.

    A radioimmunoassay for delta-9-THC in plasma, whole blood, or hemolyzed blood specimens has been presented. Samples and standards were diluted with methanol and centrifuged. An aliquot of the supernatant fluid was incubated with RIA buffer, /sup 125/I-labeled delta-8-THC and rabbit anti-THC serum. Solid phase goat anti-rabbit immunoglobulins were added to separate bound from free THC. After centrifugation the supernatant fluid was aspirated and the radioactivity of the precipitate was counted in a gamma counter. The concentration of THC was calculated from a standard curve using the logit-log transformation of the average counts of duplicate tubes. The assay had several advantages.more » Methanol dilution gave better results than direct analysis. The /sup 125/I-labeled THC had high specific activity and could be counted in a gamma counter. The immunological separation of antibody-bound THC from free THC was better than separation techniques using ammonium sulfate and activated charcoal. THC was determined in 0.1 ml of sample with a sensitivity of 1.5 ng/ml in plasma and 3.0 ng/ml in hemolyzed blood.« less

  16. Etravirine: R165335, TMC 125, TMC-125, TMC125.

    PubMed

    2006-01-01

    phase IIb dose-finding study (TMC125 C223) in Europe, Canada and the US found etravirine significantly reduced the HIV viral load in a subset of heavily treatment-experienced patients. Tibotec discontinued a single exploratory open-label phase II trial (TMC 125-C227) of etravirine in November 2005. The discontinuation was a result of 12-week data, which demonstrated a difference in the proportion of patients achieving or maintaining undetectable viral load in favour of the control group, who were receiving protease inhibitor-based treatment. There were no safety concerns and the discontinuation had no effect on phase III registration trials. Phase IIa clinical trials of etravirine for the treatment of HIV infections, initiated in November 2001, have been completed. Tibotec has conducted a phase I trial (TMC125-C157 study) evaluating etravirine + didanosine among healthy volunteers in Belgium; trial results have been presented.

  17. Seed Anatomy and Water Uptake in Relation to Seed Dormancy in Opuntia tomentosa (Cactaceae, Opuntioideae)

    PubMed Central

    Orozco-Segovia, A.; Márquez-Guzmán, J.; Sánchez-Coronado, M. E.; Gamboa de Buen, A.; Baskin, J. M.; Baskin, C. C.

    2007-01-01

    Background and Aims There is considerable confusion in the literature concerning impermeability of seeds with ‘hard’ seed coats, because the ability to take up (imbibe) water has not been tested in most of them. Seeds of Opuntia tomentosa were reported recently to have a water-impermeable seed coat sensu lato (i.e. physical dormancy), in combination with physiological dormancy. However, physical dormancy is not known to occur in Cactaceae. Therefore, the aim of this study was to determine if seeds of O. tomentosa are water-permeable or water-impermeable, i.e. if they have physical dormancy. Methods The micromorphology of the seed coat and associated structures were characterized by SEM and light microscopy. Permeability of the seed-covering layers was assessed by an increase in mass of seeds on a wet substrate and by dye-tracking and uptake of tritiated water by intact versus scarified seeds. Key Results A germination valve and a water channel are formed in the hilum–micropyle region during dehydration and ageing in seeds of O. tomentosa. The funicular envelope undoubtedly plays a role in germination of Opuntia seeds via restriction of water uptake and mechanical resistance to expansion of the embryo. However, seeds do not exhibit any of three features characteristic of those with physical dormancy. Thus, they do not have a water-impermeable layer(s) of palisade cells (macrosclereids) or a water gap sensu stricto and they imbibe water without the seed coat being disrupted. Conclusions Although dormancy in seeds of this species can be broken by scarification, they have physiological dormancy only. Further, based on information in the literature, it is concluded that it is unlikely that any species of Opuntia has physical dormancy. This is the first integrative study of the anatomy, dynamics of water uptake and dormancy in seeds of Cactaceae subfamily Opuntioideae. PMID:17298989

  18. Repair of traumatic skeletal muscle injury with bone-marrow-derived mesenchymal stem cells seeded on extracellular matrix.

    PubMed

    Merritt, Edward K; Cannon, Megan V; Hammers, David W; Le, Long N; Gokhale, Rohit; Sarathy, Apurva; Song, Tae J; Tierney, Matthew T; Suggs, Laura J; Walters, Thomas J; Farrar, Roger P

    2010-09-01

    Skeletal muscle injury resulting in tissue loss poses unique challenges for surgical repair. Despite the regenerative potential of skeletal muscle, if a significant amount of tissue is lost, skeletal myofibers will not grow to fill the injured area completely. Prior work in our lab has shown the potential to fill the void with an extracellular matrix (ECM) scaffold, resulting in restoration of morphology, but not functional recovery. To improve the functional outcome of the injured muscle, a muscle-derived ECM was implanted into a 1 x 1 cm(2), full-thickness defect in the lateral gastrocnemius (LGAS) of Lewis rats. Seven days later, bone-marrow-derived mesenchymal stem cells (MSCs) were injected directly into the implanted ECM. Partial functional recovery occurred over the course of 42 days when the LGAS was repaired with an MSC-seeded ECM producing 85.4 +/- 3.6% of the contralateral LGAS. This was significantly higher than earlier recovery time points (p < 0.05). The specific tension returned to 94 +/- 9% of the contralateral limb. The implanted MSC-seeded ECM had more blood vessels and regenerating skeletal myofibers than the ECM without cells (p < 0.05). The data suggest that the repair of a skeletal muscle defect injury by the implantation of a muscle-derived ECM seeded with MSCs can improve functional recovery after 42 days.

  19. MRI/TRUS data fusion for prostate brachytherapy. Preliminary results.

    PubMed

    Reynier, Christophe; Troccaz, Jocelyne; Fourneret, Philippe; Dusserre, André; Gay-Jeune, Cécile; Descotes, Jean-Luc; Bolla, Michel; Giraud, Jean-Yves

    2004-06-01

    Prostate brachytherapy involves implanting radioactive seeds (I125 for instance) permanently in the gland for the treatment of localized prostate cancers, e.g., cT1c-T2a N0 M0 with good prognostic factors. Treatment planning and seed implanting are most often based on the intensive use of transrectal ultrasound (TRUS) imaging. This is not easy because prostate visualization is difficult in this imaging modality particularly as regards the apex of the gland and from an intra- and interobserver variability standpoint. Radioactive seeds are implanted inside open interventional MR machines in some centers. Since MRI was shown to be sensitive and specific for prostate imaging whilst open MR is prohibitive for most centers and makes surgical procedures very complex, this work suggests bringing the MR virtually in the operating room with MRI/TRUS data fusion. This involves providing the physician with bi-modality images (TRUS plus MRI) intended to improve treatment planning from the data registration stage. The paper describes the method developed and implemented in the PROCUR system. Results are reported for a phantom and first series of patients. Phantom experiments helped characterize the accuracy of the process. Patient experiments have shown that using MRI data linked with TRUS data improves TRUS image segmentation especially regarding the apex and base of the prostate. This may significantly modify prostate volume definition and have an impact on treatment planning.

  20. CA-125 AUC as a predictor for epithelial ovarian cancer relapse.

    PubMed

    Mano, António; Falcão, Amílcar; Godinho, Isabel; Santos, Jorge; Leitão, Fátima; de Oliveira, Carlos; Caramona, Margarida

    2008-01-01

    The aim of the present work was to evaluate the usefulness of CA-125 normalized in time area under the curve (CA-125 AUC) to signalise epithelial ovarian cancer relapse. Data from a hundred and eleven patients were submitted to two different approaches based on CA-125 AUC increase values to predict patient relapse. In Criterion A total CA-125 AUC normalized in time value (AUC(i)) was compared with the immediately previous one (AUC(i-1)) using the formulae AUC(i) > or = F * AUC(i-1) (several F values were tested) to find the appropriate close related increment associated to patient relapse. In Criterion B total CA-125 AUC normalised in time was calculated and several cut-off values were correlated with patient relapse prediction capacity. In Criterion A the best accuracy was achieved with a factor (F) of 1.25 (increment of 25% from the previous status), while in Criterion B the best accuracies were achieved with cut-offs of 25, 50, 75 and 100 IU/mL. The mean lead time to relapse achieved with Criterion A was 181 days, while with Criterion B they were, respectively, 131, 111, 63 and 11 days. Based on our results we believe that conjugation and sequential application of both criteria in patient relapse detection should be highly advisable. CA-125 AUC rapid burst in asymptomatic patients should be firstly evaluated using Criterion A with a high accuracy (0.85) and with a substantial mean lead time to relapse (181 days). If a negative answer was obtained then Criterion B should performed to confirm the absence of relapse.

  1. Nutritional prognostic scores in patients with hilar cholangiocarcinoma treated by percutaneous transhepatic biliary stenting combined with 125I seed intracavitary irradiation: A retrospective observational study.

    PubMed

    Cui, Peiyuan; Pang, Qing; Wang, Yong; Qian, Zhen; Hu, Xiaosi; Wang, Wei; Li, Zongkuang; Zhou, Lei; Man, Zhongran; Yang, Song; Jin, Hao; Liu, Huichun

    2018-06-01

    We mainly aimed to preliminarily explore the prognostic values of nutrition-based prognostic scores in patients with advanced hilar cholangiocarcinoma (HCCA).We retrospectively analyzed 73 cases of HCCA, who underwent percutaneous transhepatic biliary stenting (PTBS) combined with I seed intracavitary irradiation from November 2012 to April 2017 in our department. The postoperative changes of total bilirubin (TBIL), direct bilirubin (DBIL), alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and albumin (ALB) were observed. The preoperative clinical data were collected to calculate the nutrition-based scores, including controlling nutritional status (CONUT), C-reactive protein/albumin ratio (CAR), and prognostic nutritional index (PNI). Kaplan-Meier curve and Cox regression model were used for overall survival (OS) analyses.The serum levels of TBIL, DBIL, ALT, AST, and ALP significantly reduced, and ALB significantly increased at 1 month and 3 months postoperatively. The median survival time of the cohort was 12 months and the 1-year survival rate was 53.1%. Univariate analysis revealed that the statistically significant factors related to OS were CA19-9, TBIL, ALB, CONUT, and PNI. Multivariate analysis further identified CA19-9, CONUT, and PNI as independent prognostic factors.Nutrition-based prognostic scores, CONUT and PNI in particular, can be used as predictors of survival in unresectable HCCA.

  2. Neointimal hyperplasia on a cell-seeded polytetrafluoroethylene graft is promoted by transfer of tissue plasminogen activator gene and inhibited by transfer of nitric oxide synthase gene.

    PubMed

    Yu, Hong; Dai, Wangde; Yang, Zhe; Romaguera, Rita L; Kirkman, Paul; Rowe, Vincent L

    2005-01-01

    The objective of this study was to examine the effect of tissue plasminogen activator (tPA) and endothelial nitric oxide synthase (eNOS) on thrombosis and neointimal hyperplasia on a polytetrafluoroethylene (PTFE) graft seeded with smooth muscle cells (SMCs). SMCs retrovirally transduced with tPA and eNOS genes were seeded on PTFE grafts and then implanted into the infrarenal rabbit aorta. Thrombosis and neointimal hyperplasia on the grafts were examined after 30 and 100 days of implantation. At 30 days of implantation, thrombus was observed on the luminal surface of both unseeded and SMC seeded control grafts, whereas grafts seeded with SMCs secreting tPA were nearly free of thrombus. At 100 days, the neointima on grafts seeded with tPA transduced SMCs was significantly thicker (925 +/- 150 microm, n = 5) than neointima on the other grafts (range, 132 to 374 microm; P < .001). Neointima thickness on grafts seeded with eNOS transduced SMCs (154 +/- 27 microm) was similar to that of unseeded grafts (132 +/- 16 microm, P > .05); both were thinner than those on grafts seeded with SMCs transduced with only lacZ gene (287 +/- 35 microm). The ratio of seeded cells in the neointima was significantly higher on SMC/tPA grafts (46% +/- 8%) than SMC/NOS grafts (21% +/- 6%, P < .05), indicating tPA transduced cells proliferated more than eNOS transduced cells. Engineered tPA expression in seeded SMCs causes significantly more neointimal hyperplasia, despite the favorable inhibition of luminal thrombus. eNOS expression in the seeded cells inhibits neointimal hyperplasia.

  3. Experience with a commercial preparation of 125I-labelled human albumin for study of albumin metabolism

    PubMed Central

    Ballantyne, Fiona C.; Fleck, A.

    1973-01-01

    Evaluation of a commercial preparation of 125I-labelled albumin for use in the study of albumin metabolism is described. In eight subjects with normal albumin metabolism the proportion of the dose of radioiodide excreted was stable throughout a period of 17 days, indicating that there was no excessive denaturation of the iodinated albumin. Characteristics of albumin metabolism—pool sizes, catabolic rate, etc—were in agreement with currently accepted normal values. It is concluded that this preparation of iodinated albumin is suitable for metabolic use. PMID:4727059

  4. Chemical composition and antimicrobial activity of the essential oil of apricot seed.

    PubMed

    Lee, Hyun-Hee; Ahn, Jeong-Hyun; Kwon, Ae-Ran; Lee, Eun Sook; Kwak, Jin-Hwan; Min, Yu-Hong

    2014-12-01

    In traditional oriental medicine, apricot (Prunus armeniaca L.) seed has been used to treat skin diseases such as furuncle, acne vulgaris and dandruff, as well as coughing, asthma and constipation. This study describes the phytochemical profile and antimicrobial potential of the essential oil obtained from apricot seeds (Armeniacae Semen). The essential oil isolated by hydrodistillation was analysed by gas chromatography-mass spectroscopy. Benzaldehyde (90.6%), mandelonitrile (5.2%) and benzoic acid (4.1%) were identified. Disc diffusion, agar dilution and gaseous contact methods were performed to determine the antimicrobial activity against 16 bacteria and two yeast species. The minimum inhibitory concentrations ranged from 250 to 4000, 500 to 2000 and 250 to 1000 µg/mL for Gram-positive bacteria, Gram-negative bacteria and yeast strains, respectively. The minimum inhibitory doses by gaseous contact ranged from 12.5 to 50, 12.5 to 50 and 3.13 to 12.5 mg/L air for Gram-positive bacteria, Gram-negative bacteria and yeast strains, respectively. The essential oil exhibited a variable degree of antimicrobial activity against a range of bacteria and yeasts tested. Copyright © 2014 John Wiley & Sons, Ltd.

  5. A comparison of postimplant dosimetry for {sup 103}Pd versus {sup 131}Cs seeds on a retrospective series of PBSI patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ravi, Ananth; Keller, Brian M.; Pignol, Jean-Philippe

    2011-11-15

    Purpose: Permanent breast seed implantation (PBSI) is an accelerated partial breast irradiation technique performed using stranded {sup 103}Pd radioactive seeds (average energy of 21 keV, 16.97 day half-life). Since 2004, {sup 131}Cs brachytherapy sources have become clinically available. The {sup 131}Cs radionuclide has a higher energy (average energy of 30 keV) and a shorter half-life (9.7 days) than {sup 103}Pd. The purpose of this study was to determine whether or not there are dosimetric benefits to using {sup 131}Cs brachytherapy seeds for PBSI. Methods: The prescribed dose for PBSI using {sup 103}Pd is 90 Gy, which was adjusted for {supmore » 131}Cs implants to account for the shorter half-life. A retrospective cohort of 30 patients, who have already undergone a {sup 103}Pd implant, was used for this study. The treatments were planned using the Variseed treatment planning system. The air kerma strength of the {sup 131}Cs seeds was adjusted in all preimplantation treatment plans so that the V{sub 100} (the volume within the target that receives 100% or more of the prescribed dose) were equivalent at time of implantation. Two month follow-up CT scans were available for all 30 patients and each patient was reevaluated using {sup 131}Cs seeds. The postimplant dosimetric parameters were compared using a two tailed t-test. Results: The prescribed dose for {sup 131}Cs was calculated to be 77 Gy; this dose would have the same biological effect as a PBSI implant with {sup 103}Pd of 90 Gy. The activities of the {sup 131}Cs sources were adjusted to an average of 2.2 {+-} 0.8 U for {sup 131}Cs compared to 2.5 {+-} 1.1 U for {sup 103}Pd in order to get an equivalent V{sub 100} as the {sup 103}Pd preimplants. While the use of {sup 131}Cs significantly reduces the preimplant V{sub 200} (the volume within the target that receives 200% or more of the prescribed dose) compared to {sup 103}Pd by 13.5 {+-} 9.0%, the reduction observed on the 2 month postimplant plan was 12

  6. Vibro-acoustography with 1.75D ultrasound array transducer for detection and localization of permanent prostate brachytherapy seeds: ex vivo study

    NASA Astrophysics Data System (ADS)

    Mehrmohammadi, Mohammad; Alizad, Azra; Kinnick, Randall R.; Davis, Brian J.; Fatemi, Mostafa

    2013-03-01

    Effective brachytherapy procedures require precise placement of radioactive seeds in the prostate. Currently, transrectal ultrasound (TRUS) imaging is one of the main intraoperative imaging modalities to assist physicians in placement of brachytherapy seeds. However, the seed detection rate with TRUS is poor mainly because ultrasound imaging is highly sensitive to variations in seed orientation. The purpose of this study is to investigate the abilities of a new acoustic radiation force imaging modality, vibro-acoustography (VA), equipped with a 1.75D array transducer and implemented on a customized clinical ultrasound scanner, to image and localize brachytherapy seeds in prostatic tissue. To perform experiments, excised cadaver prostate specimens were implanted with dummy brachytherapy seeds, and embedded in tissue mimicking gel to simulate the properties of the surrounding soft tissues. The samples were scanned using the VA system and the resulting VA signals were used to reconstruct VA images at several depths inside the tissue. To further evaluate the performance of VA in detecting seeds, X-ray computed tomography (CT) images of the same tissue sample, were obtained and used as a gold-standard to compare the number of seeds detected by the two methods. Our results indicate that VA is capable of imaging of brachytherapy seeds with accuracy and high contrast, and can detect a large percentage of the seeds implanted within the tissue samples.

  7. Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

    PubMed

    Pokhrel, Damodar; Murphy, Martin J; Todor, Dorin A; Weiss, Elisabeth; Williamson, Jeffrey F

    2011-01-01

    To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 degrees, respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78 +/- 0.57) mm or less. The theta and phi angle errors were found to be (5.7 +/- 4.9) degrees and (6.0 +/- 4.1) degrees, respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 degrees compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. This work describes a novel, accurate, and completely automatic method for reconstructing seed orientations, as well as

  8. Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.

    2011-01-15

    Purpose: To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. Methods: The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations weremore » performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. Results: In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 deg., respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78{+-}0.57) mm or less. The {theta} and {phi} angle errors were found to be (5.7{+-}4.9) deg. and (6.0{+-}4.1) deg., respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 deg. compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. Conclusions: This work describes a novel, accurate, and completely automatic method for

  9. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    PubMed Central

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor

    2011-01-01

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use. PMID:21992346

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Zhongmin, E-mail: wzm0722@hotmail.com; Huang Xunbo, E-mail: huangxunbo0722@hotmail.com; Cao Jun, E-mail: caojun88888@hotmail.com

    Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consentmore » was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.« less

  11. The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources.

    PubMed

    Landry, Guillaume; Reniers, Brigitte; Pignol, Jean-Philippe; Beaulieu, Luc; Verhaegen, Frank

    2011-03-01

    The goal of this work is to compare D(m,m) (radiation transported in medium; dose scored in medium) and D(w,m) (radiation transported in medium; dose scored in water) obtained from Monte Carlo (MC) simulations for a subset of human tissues of interest in low energy photon brachytherapy. Using low dose rate seeds and an electronic brachytherapy source (EBS), the authors quantify the large cavity theory conversion factors required. The authors also assess whether ap plying large cavity theory utilizing the sources' initial photon spectra and average photon energy induces errors related to spatial spectral variations. First, ideal spherical geometries were investigated, followed by clinical brachytherapy LDR seed implants for breast and prostate cancer patients. Two types of dose calculations are performed with the GEANT4 MC code. (1) For several human tissues, dose profiles are obtained in spherical geometries centered on four types of low energy brachytherapy sources: 125I, 103Pd, and 131Cs seeds, as well as an EBS operating at 50 kV. Ratios of D(w,m) over D(m,m) are evaluated in the 0-6 cm range. In addition to mean tissue composition, compositions corresponding to one standard deviation from the mean are also studied. (2) Four clinical breast (using 103Pd) and prostate (using 125I) brachytherapy seed implants are considered. MC dose calculations are performed based on postimplant CT scans using prostate and breast tissue compositions. PTV D90 values are compared for D(w,m) and D(m,m). (1) Differences (D(w,m)/D(m,m)-1) of -3% to 70% are observed for the investigated tissues. For a given tissue, D(w,m)/D(m,m) is similar for all sources within 4% and does not vary more than 2% with distance due to very moderate spectral shifts. Variations of tissue composition about the assumed mean composition influence the conversion factors up to 38%. (2) The ratio of D90(w,m) over D90(m,m) for clinical implants matches D(w,m)/D(m,m) at 1 cm from the single point sources, Given

  12. Strong association between a splice mutation (IVS12+5G{r_arrow}A) and haplotype 6 in hereditary tyrosinemia type I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanguay, R.M.; St-Louis, M.; Gibson, K.

    1994-09-01

    Hereditary tyrosinemia type I (HT I; McKusick 276700) is a severe inborn error of tyrosine catabolism pathway caused by a deficiency of fumarylacetoacetate hydrolase (FAH). The highest frequency reported is the one in Saguenay-Lac St-Jean (Quebec, Canada) where 1:1,846 births are affected. The FAH gene has been cloned and several mutations have been described. Allele specific oligonucleotide (ASO) hybridization was used to examine the frequency of a splice (IVS12-5G{r_arrow}A) mutation recently reported and RFLP analysis was done to identify haplotypes related to HT I. The splice mutation was found on 45/50 alleles (90%) in patients from SLSJ and 12/66 (18%)more » alleles from patients world-wide. All 25 patients from the SLSJ region were positive with 20 being homozygous, indicating that this mutation is the major cause of HT I in French Canada. Of these 25 patients, 96% were positive for one haplotype called no 6 which is these 25 patients, 96% were positive for one haplotype called no 6 which is identified by TaqI, RsaI, BglII, MspI and KpnI digestions. These data show a really strong association between the mutation (IVS12+5G{r_arrow}A) and haplotype 6. Among our patients from around the world, {approximately}52% were positive for haplotype 6 indicating its strong relation with HT I. These results provide the rationale for DNA-based carrier testing for HT I in the F-C population at risk as well as in HT I patients in general.« less

  13. Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy.

    PubMed

    Sutherland, J G H; Miksys, N; Furutani, K M; Thomson, R M

    2014-01-01

    To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for (125)I, (103)Pd, and (131)Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed

  14. Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, J. G. H.; Miksys, N.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca

    2014-01-15

    Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxelmore » and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue

  15. Mustard seed meal mixtures: management of Meloidogyne incognita on pepper and potential phytotoxicity

    PubMed Central

    Zasada, Inga A.; Orisajo, Samuel B.; Morra, Matthew J.

    2011-01-01

    Meals produced when oil is extracted from seeds in the Brassicaceae have been shown to suppress weeds and soilborne pathogens. These seed meals are commonly used individually as soil amendments; the goal of this research was to evaluate seed meal mixes of Brassica juncea (Bj) and Sinapis alba (Sa) against Meloidogyne incognita. Seed meals from Bj ‘Pacific Gold’ and Sa ‘IdaGold’ were tested alone and in combinations to determine rates and application times that would suppress M. incognita on pepper (Capsicum annuum) without phytotoxicity. Rates of soil application (% w/w) for the phytotoxicity study were: 0.5 Sa, 0.2 Bj, 0.25 Sa + 0.25 Bj, 0.375 Sa + 0.125 Bj, 0.125 Sa + 0.375 Bj, and 0, applied 0 – 5 weeks before transplant. Overall, 0.2% Bj was the least toxic meal to pepper seedlings. By comparison, 0.5% S. alba seed meal did not reduce lettuce (Lactuca sativa) seed germination at week 0, but all seed meal treatments containing B. juncea prevented or significantly reduced germination at week 0. The seed meals did not affect lettuce seed germination at weeks 1-5, but hypocotyl growth was reduced by all except 0.2% Bj at weeks 1, 4 and 5. Brassica juncea and Sa meals were tested for M. incognita suppression at 0.2, 0.15, 0.1 and 0.05%; mixtures were 0.1% Sa + 0.1% Bj, 0.15% Sa + 0.05% Bj, and 0.05% Sa + 0.15% Bj. All treatments were applied 2 weeks before transplant. The 0.2% Bj and 0.05% Sa + 0.15% Bj treatments overall had the longest shoots and highest fresh weights. Eggs per g root were lowest with 0.1 – 0.2% Bj amendments and the seed meal mixtures. The results indicate that Bj and some Bj + Sa mixtures can be applied close to transplant to suppress M. incognita populations on pepper; consequently, a seed meal mixture could be selected to provide activity against more than one pest or pathogen. For pepper, care should be taken in formulating mixtures so that Sa rates are low compared to Bj. PMID:22791910

  16. Correlation of cytotoxicity with elimination of iodine-125 from nude mice inoculated with prelabeled human melanoma cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockshin, A.; Giovanella, B.C.; Quian, C.

    1984-08-01

    BRO human melanoma cells were prelabeled in vitro with (125I)5-iodo-2'-deoxyuridine ((125I)IdUrd) and inoculated into NIH-II nude mice ip, im, sc, or iv. Saline or diphtheria toxin (DT), which is selectively toxic to human cells compared to those of mice, was injected, and the loss of 125I from the animals was monitored daily with a whole-body gamma scintillation detector. For most of the inoculation sites DT accelerated the rate of 125I excretion and in all cases was cytotoxic for the inoculated cells as determined by host survival or measurement of visible tumor growth. Differences between the rates of 125I loss formore » DT-treated mice compared to untreated mice were most evident for cells inoculated ip or im. These results indicate that (125I)IdUrd prelabeling of human tumor cells inoculated in nude mice offers a rapid method for determination of cytotoxicity in vivo.« less

  17. The Recent Revolution in the Design and Manufacture of Cranial Implants: Modern Advancements and Future Directions

    PubMed Central

    Bonda, David J.; Manjila, Sunil; Selman, Warren R.; Dean, David

    2015-01-01

    Large format (i.e., > 25 cm2) cranioplasty is a challenging procedure not only from a cosmesis standpoint, but also in terms of ensuring that the patient's brain will be well-protected from direct trauma. Until recently, when a patient's own cranial flap was unavailable, these goals were unattainable. Recent advances in implant Computer Aided Design and 3-D printing are leveraging other advances in regenerative medicine. It is now possible to 3-D-print patient-specific implants from a variety of polymer, ceramic, or metal components. A skull template may be used to design the external shape of an implant that will become well integrated in the skull, while also providing beneficial distribution of mechanical force distribution in the event of trauma. Furthermore, an internal pore geometry can be utilized to facilitate the seeding of banked allograft cells. Implants may be cultured in a bioreactor along with recombinant growth factors to produce implants coated with bone progenitor cells and extracellular matrix that appear to the body as a graft, albeit a tissue-engineered graft. The growth factors would be left behind in the bioreactor and the graft would resorb as new host bone invades the space and is remodeled into strong bone. As we describe in this review, such advancements will lead to optimal replacement of cranial defects that are both patient-specific and regenerative. PMID:26171578

  18. Optimized cell survival and seeding efficiency for craniofacial tissue engineering using clinical stem cell therapy.

    PubMed

    Rajan, Archana; Eubanks, Emily; Edwards, Sean; Aronovich, Sharon; Travan, Suncica; Rudek, Ivan; Wang, Feng; Lanis, Alejandro; Kaigler, Darnell

    2014-12-01

    Traumatic injuries involving the face are very common, yet the clinical management of the resulting craniofacial deficiencies is challenging. These injuries are commonly associated with missing teeth, for which replacement is compromised due to inadequate jawbone support. Using cell therapy, we report the upper jaw reconstruction of a patient who lost teeth and 75% of the supporting jawbone following injury. A mixed population of bone marrow-derived autologous stem and progenitor cells was seeded onto β-tricalcium phosphate (β-TCP), which served as a scaffold to deliver cells directly to the defect. Conditions (temperature, incubation time) to achieve the highest cell survival and seeding efficiency were optimized. Four months after cell therapy, cone beam computed tomography and a bone biopsy were performed, and oral implants were placed to support an engineered dental prosthesis. Cell seeding efficiency (>81%) of the β-TCP and survival during the seeding process (94%) were highest when cells were incubated with β-TCP for 30 minutes, regardless of incubation temperature; however, at 1 hour, cell survival was highest when incubated at 4°C. Clinical, radiographic, and histological analyses confirmed that by 4 months, the cell therapy regenerated 80% of the original jawbone deficiency with vascularized, mineralized bone sufficient to stably place oral implants. Functional and aesthetic rehabilitation of the patient was successfully completed with installation of a dental prosthesis 6 months following implant placement. This proof-of-concept clinical report used an evidence-based approach for the cell transplantation protocol used and is the first to describe a cell therapy for craniofacial trauma reconstruction. ©AlphaMed Press.

  19. 40 CFR 125.59 - General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... modification by supplying to EPA the results of studies and monitoring performed in accordance with § 125.63..., regulations (44 FR 34784) may revise their applications one time following a tentative decision to propose...)(2)(i); and (2) Other applicants may revise their applications one time following a tentative...

  20. 40 CFR 125.59 - General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... modification by supplying to EPA the results of studies and monitoring performed in accordance with § 125.63..., regulations (44 FR 34784) may revise their applications one time following a tentative decision to propose...)(2)(i); and (2) Other applicants may revise their applications one time following a tentative...

  1. 40 CFR 125.59 - General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... modification by supplying to EPA the results of studies and monitoring performed in accordance with § 125.63..., regulations (44 FR 34784) may revise their applications one time following a tentative decision to propose...)(2)(i); and (2) Other applicants may revise their applications one time following a tentative...

  2. 40 CFR 125.59 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... modification by supplying to EPA the results of studies and monitoring performed in accordance with § 125.63..., regulations (44 FR 34784) may revise their applications one time following a tentative decision to propose...)(2)(i); and (2) Other applicants may revise their applications one time following a tentative...

  3. 40 CFR 125.59 - General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... modification by supplying to EPA the results of studies and monitoring performed in accordance with § 125.63..., regulations (44 FR 34784) may revise their applications one time following a tentative decision to propose...)(2)(i); and (2) Other applicants may revise their applications one time following a tentative...

  4. Apricot and other seed stones: amygdalin content and the potential to obtain antioxidant, angiotensin I converting enzyme inhibitor and hypocholesterolemic peptides.

    PubMed

    García, M C; González-García, E; Vásquez-Villanueva, R; Marina, M L

    2016-11-09

    Stones from olives and Prunus genus fruits are cheap and sustainable sources of proteins and could be potential sources of bioactive peptides. The main limitation to the use of these seeds is the presence of amygdalin. This work proposes to determine amygdalin in olive and Prunus seeds and in protein isolates obtained from them. Moreover, antioxidant, angiotensin I converting enzyme (ACE) inhibitor, and hypocholesterolemic properties will be evaluated in hydrolysates obtained from these seeds. Despite some seeds contained amygdalin, all protein isolates were free of this substance. Two different procedures to obtain bioactive peptides from protein isolates were examined: gastrointestinal digestion and processing with Alcalase, Flavourzyme or Thermolysin. Higher antioxidant, ACE inhibitor and hypocholesterolemic activities were observed when proteins were processed with Alcalase, Flavourzyme or Thermolysin. The highest antioxidant and ACE inhibitor capacities were observed for the Prunus genus seed hydrolysates while the highest capacity to reduce micellar cholesterol solubility was observed for the apricot and olive seed hydrolysates.

  5. The Influence of the Crown-Implant Ratio on the Crestal Bone Level and Implant Secondary Stability: 36-Month Clinical Study.

    PubMed

    Hadzik, Jakub; Krawiec, Maciej; Sławecki, Konstanty; Kunert-Keil, Christiane; Dominiak, Marzena; Gedrange, Tomasz

    2018-01-01

    When the era of dental implantology began, the pioneers defined some gold standards used in dental prosthetics treatment for implant-supported restorations. Referring to traditional prosthetics, it was taken for granted that the length of an implant placed in the alveolar bone (the equivalent of the root) should exceed the length of the superstructure. The aim of the study was to determine whether implant length and the crown-to-implant ( C / I ) ratio influence implant stability and the loss of the surrounding marginal bone and whether short implants can be used instead of sinus augmentation procedures. The patients participating in the study ( n = 30) had one single tooth implant, a short (OsseoSpeed™ L6 Ø4 mm, Implants) or a regular implant (OsseoSpeed L11 and L13 Ø4 mm, DENTSPLY Implants), placed in the maxilla. The evaluation was based on clinical and radiological examination. The crown-to-implant ratio was determined by dividing the length of the crown together with the abutment by the length of the implant placed crestally. Mean crown-to-implant ratios were calculated separately for each group and its correlation with the MBL (marginal bone loss) and stability was assessed. The authors compared the correlation between the C / I ratio values, MBL, and secondary implant stability. Positive results in terms of primary and secondary stability were achieved with both (short and conventional) implants. The MBL was low for short and conventional implants being 0.34 ± 0.24 mm and 0.22 ± 0.46 mm, respectively. No significant correlation was found between the C / I ratio and secondary stability as well as the C / I ratio and the marginal bone loss. Short implants can be successfully used to support single crowns. The study has revealed no significant differences in the clinical performance of prosthetic restorations supported by short implants. Clinical trial registration number is NCT03471000.

  6. Implant-buccal plate distance as diagnostic parameter: a prospective cohort study on implant placement in fresh extraction sockets.

    PubMed

    Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo

    2013-12-01

    The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP <4 mm), only the peri-implant gap was grafted during the surgical phase (internal grafting [IG]), whereas group B (I-BP ≥ 4 mm) received both internal and external grafting (IEG). Master casts of the sites, made before implant placement and after 1 year of loading, were optically scanned. A computerized analysis of the contour changes at the involved sites was performed by superimposing the scanned models. A total of 20 patients (eight males and 12 females) were recruited, and 20 non-submerged implants were placed in fresh extraction sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.

  7. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

    PubMed

    Rocci, A; Calcaterra, R; DI Girolamo, M; Rocci, M; Rocci, C; Baggi, L

    2015-01-01

    Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. No statistical significance differences were found among the mean percentage of BIC of Group I - type A were 66,51% versus 49,96% in Group I - type B, as well as among the mean percentage of BIC of Group II - type A were 43.7% versus 60.02% in Group II - type B. Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface.

  8. [Clinical Trial to Test the iFuse Implant System® in Patients with Sacroiliac Joint Syndrome: One Year Results].

    PubMed

    Bornemann, R; Pflugmacher, R; Webler, M; Koch, E M W; Dengler, J; Wirtz, D C; Frey, S P

    2016-12-01

    Background: This study reports one year post-operative monitoring of the efficacy and safety of iFuse Implant System® in patients with sacroiliac joint syndrome. Material and Methods: After 6 months of inadequate conservative treatment, patients with properly proven ISG syndrome were selected for surgery. The iFuse implants had a triangular profile and coating of porous titanium plasma spray and were used in the minimally invasive procedures. The procedure was performed under general anaesthesia and fluoroscopic control. In each case, three implants were placed. Results: 24 patients (22 f; 92 %; 54.9 ± 14 years) participated in the study. The operations were performed in 11 patients (46 %) on the left and in 13 patients (54 %) on the right. The mean operative time was 42.4 minutes (95 % CI: 35.6-49.3). The reduction in pain intensity on the VAS scale was 58 ± 11 mm (68 ± 7 %). The Oswestry score showed a median decrease of 44 percentage points (57 %). After 12 months, 15 patients (63 %) reported that they were taking no more painkillers. Conclusion: The minimally invasive treatment of patients with sacroiliac joint syndrome using the iFuse Implant System leads to significant analgesic effects over the period of one year; it also contributes significantly to improving the functioning of the patient. Georg Thieme Verlag KG Stuttgart · New York.

  9. Electromagnetic semi-implantable hearing device: phase I. Clinical trials.

    PubMed

    McGee, T M; Kartush, J M; Heide, J C; Bojrab, D I; Clemis, J D; Kulick, K C

    1991-04-01

    Conventional hearing aids have improved significantly in recent years; however, amplification of sound within the external auditory canal creates a number of intrinsic problems, including acoustic feedback and the need for a tight ear mold to increase usable gain. Nonacoustic alternatives which could obviate these encumbrances have not become practical due to inefficient coupling (piezoelectric techniques) or unfeasible power requirements (electromagnetic techniques). Recent technical advances, however, prompted a major clinical investigation of a new electromagnetic, semi-implantable hearing device. This study presents the details of clinical phase I, in which an electromagnetic driver was coupled with a target magnet temporarily affixed onto the lateral surface of the malleus of six hearing aid users with sensorineural losses. The results indicate that the electromagnetic hearing device provides sufficient gain and output characteristics to benefit individuals with sensorineural hearing loss. Significant improvements compared to conventional hearing aids were noted in pure-tone testing and, to a lesser degree, in speech discrimination. Subjective responses were quite favorable, indicating that the electromagnetic hearing device 1. produces no acoustic feedback; 2. works well in noisy environments; and 3. provides a more quiet, natural sound than patients' conventional hearing aids. These favorable results led to phase II of the project, in which patients with surgically amendable mixed hearing losses were implanted with the target magnet incorporated within a hydroxyapatite ossicular prosthesis. The results of this second-stage investigation were also encouraging and will be reported separately.

  10. Phase I Trial of Adenovirus-Mediated IL-12 Gene Transduction in Patients with Recurrent Locally Advanced Prostate Cancer Following Therapy

    DTIC Science & Technology

    2005-10-01

    salvage seed implant, cryotherapy ) or who have a rising PSA while on hormone therapy for locally advanced prostate cancer are as follows: a. A...Gene Transduction in Patients with Recurrent Locally Advanced Prostate Cancer Following Therapy PRINCIPAL INVESTIGATOR: Simon J. Hall, MD...CONTRACT NUMBER Phase I Trial of Adenovirus-Mediated IL-12 Gene Transduction in Patients with Recurrent Locally Advanced Prostate Cancer Following

  11. Dose Constraint for Minimizing Grade 2 Rectal Bleeding Following Brachytherapy Combined With External Beam Radiotherapy for Localized Prostate Cancer: Rectal Dose-Volume Histogram Analysis of 457 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiraishi, Yutaka; Yorozu, Atsunori; Ohashi, Toshio, E-mail: ohashi@rad.med.keio.ac.jp

    2011-11-01

    Purpose: To determine the rectal tolerance to Grade 2 rectal bleeding after I-125 seed brachytherapy combined with external beam radiotherapy (EBRT), based on the rectal dose-volume histogram. Methods and Materials: A total of 458 consecutive patients with stages T1 to T3 prostate cancer received combined modality treatment consisting of I-125 seed implantation followed by EBRT to the prostate and seminal vesicles. The prescribed doses of brachytherapy and EBRT were 100 Gy and 45 Gy in 25 fractions, respectively. The rectal dosimetric factors were analyzed for rectal volumes receiving >100 Gy and >150 Gy (R100 and R150) during brachytherapy and formore » rectal volumes receiving >30 Gy to 40 Gy (V30-V40) during EBRT therapy in 373 patients for whom datasets were available. The patients were followed from 21 to 72 months (median, 45 months) after the I-125 seed implantation. Results: Forty-four patients (9.7%) developed Grade 2 rectal bleeding. On multivariate analysis, age (p = 0.014), R100 (p = 0.002), and V30 (p = 0.001) were identified as risk factors for Grade 2 rectal bleeding. The rectal bleeding rate increased as the R100 increased: 5.0% (2/40 patients) for 0 ml; 7.5% (20/267 patients) for >0 to 0.5 ml; 11.0% (11/100 patients) for >0.5 to 1 ml; 17.9% (5/28 patients) for >1 to 1.5 ml; and 27.3% (6/22 patients) for >1.5 ml (p = 0.014). Grade 2 rectal bleeding developed in 6.4% (12/188) of patients with a V30 {<=}35% and in 14.1% (26/185) of patients with a V30 >35% (p = 0.02). When these dose-volume parameters were considered in combination, the Grade 2 rectal bleeding rate was 4.2% (5/120 patients) for a R100 {<=}0.5 ml and a V30 {<=}35%, whereas it was 22.4% (13/58 patients) for R100 of >0.5 ml and V30 of >35%. Conclusion: The risk of rectal bleeding was found to be significantly volume-dependent in patients with prostate cancer who received combined modality treatment. Rectal dose-volume analysis is a practical method for predicting the risk of

  12. Selective down-regulation of [(125)I]Y0-alpha-conotoxin MII binding in rat mesostriatal dopamine pathway following continuous infusion of nicotine.

    PubMed

    Mugnaini, M; Garzotti, M; Sartori, I; Pilla, M; Repeto, P; Heidbreder, C A; Tessari, M

    2006-01-01

    Prolonged exposure to nicotine, as occurs in smokers, results in up-regulation of all the neuronal nicotinic acetylcholine receptor subtypes studied so far, the only differences residing in the extent and time course of the up-regulation. alpha6beta2*-Nicotinic acetylcholine receptors are selectively enriched in the mesostriatal dopaminergic system and may play a crucial role in nicotine dependence. Here we show that chronic nicotine treatment (3mg/kg/day for two weeks, via s.c. osmotic minipumps) caused a significant decrease (36% on average) in the binding of [(125)I]Y(0)-alpha-conotoxin MII (a selective ligand for alpha6beta2*-nicotinic acetylcholine receptors in this system) to all the five regions of the rat dopaminergic pathway analyzed in this study. After one week of withdrawal, binding was still lower than control in striatal terminal regions (namely the caudate putamen and the accumbens shell and core). In somatodendritic regions (the ventral tegmental area and the substantia nigra) the decrease was significant at the end of the treatment and recovered within one day of withdrawal. This effect was not due to displacement of [(125)I]Y(0)-alpha-conotoxin MII binding by residual nicotine. In fact the binding was not changed by 565 ng/g nicotine (obtained with a single injection of nicotine), a concentration much higher than that found in the brain of rats chronically treated with nicotine (240 ng/g). In addition, consistent with previous studies reporting an up-regulation of other subtypes of nicotinic acetylcholine receptors, we found that nicotine exposure significantly increased (40% on average) the binding of [(125)I]epibatidine (a non-selective agonist at most neuronal heteromeric nicotinic acetylcholine receptors) in three up to five regions containing only alpha-conotoxin MII-insensitive [(125)I]epibatidine binding sites, namely the primary motor, somatosensory and auditory cortices. In conclusion, this work is the first to demonstrate that alpha6beta

  13. 76 FR 31790 - Federal Seed Act Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... nomenclature of many of the kinds of agricultural and vegetable seeds listed in Sec. Sec. 201.2(h) and 201.2(i... regulations for determining pure seed and inert matter for 18 grass seed kinds. The change will require pure... also require seeds of these 18 grass kinds to be classified as inert matter if the caryopsis...

  14. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study

    PubMed Central

    ROCCI, A.; CALCATERRA, R.; DI GIROLAMO, M.; ROCCI, M.; ROCCI, C.; BAGGI, L.

    2015-01-01

    SUMMARY Objective Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. Material and method The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. Results No statistical significance differences were found among the mean percentage of BIC of Group I – type A were 66,51% versus 49,96% in Group I – type B, as well as among the mean percentage of BIC of Group II – type A were 43.7% versus 60.02% in Group II – type B. Conclusions Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface. PMID:28042421

  15. Super-hard cubic BN layer formation by nitrogen ion implantation

    NASA Astrophysics Data System (ADS)

    Komarov, F. F.; Pilko, V. V.; Yakushev, V. A.; Tishkov, V. S.

    1994-11-01

    Microcrystalline and amorphous boron thin films were implanted with nitrogen ions at energies from 25 to 125 keV and with doses from 2 × 10 17 to 1 × 10 18 at.cm 2 at temperatures below 200°C. The structure of boron nitride phases after ion implantation, formation of phases and phase transformations were investigated by TEM and TED methods. The cubic boron nitride phase is revealed. The microhardness of the formed films was satisfactorily explained in terms of chemical compound formation by polyenergetic ion implantation. The influence of the copper impurity on the formation of the cubic boron nitride phase is demonstrated. It has also been shown that low concentrations of copper promote cubic BN boundary formation.

  16. Stimulation of in vivo hepatic uptake and in vitro hepatic binding of (/sup 125/I)2-lodo-3,7,8-trichlorodibenzo-p-dioxin by the administration of agonist for the Ah receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poland, A.; Teitelbaum, P.; Glover, E.

    1989-07-01

    (125I)2-lodo-3,7,8-trichlorodibenzo-p-dioxin ((125I)Cl3DpD), a radiolabeled, isosteric, analogue of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), was synthesized and used to study in vivo tissue localization and in vivo tissue binding. Twenty-four hours after the administration of a tracer dose (1 X 10(-10) mol/kg) of (125I) Cl3DpD to C57BL/6J mice, the hepatic concentration of radioactivity was 1-2% of the administered dose, whereas in mice pretreated with TCDD (1 X 10(-7) mol/kg), the hepatic accumulation of radiolabel was 25-30% of that administered. Liver homogenate from TCDD-treated mice bound 4 to 10 times more (125I)Cl3DpD than homogenate from control mice. The enhancement of in vivo uptake and in vitromore » tissue binding of (125I)Cl3DpD by TCDD administration was confined to liver and was not observed in other tissues examined, kidney, lung, spleen, small intestines, and muscle. The administration of TCDD to C57BL/6J mice produces dose-related stimulation of in vivo hepatic uptake of (125I)Cl3DpD, binding of radioligand to liver homogenate, and hepatic aryl hydrocarbon hydroxylase activity, with the dose for half-maximal stimulation, ED50, varying from 1.5 to 4.0 x 10(-9) mol/kg. In congenic C57BL/6J (Ahd/Ahd) mice, which express the lower affinity Ah receptor, the ED50 values for all three responses were shifted to approximately 10-fold higher doses. 3,3',4,4',5,5'-Hexabromobiphenyl, a weak agonist for the Ah receptor produced a dose-related stimulation of these three responses in C57BL/6J mice (ED50 values of approximately 5 X 10(-7) mol/kg), but was without effect in C57BL/6J (Ahd/Ahd) mice. Stimulation of vivo hepatic uptake and in vitro liver homogenate binding of (125I)Cl3DpD was produced by administration of Ah agonists, such as 2,3,7,8-tetrachlorodibenzofuran and beta-naphthoflavone, but inactive congeners and other compounds that do not act via the Ah receptor.« less

  17. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.

    PubMed

    Husser, Oliver; Kessler, Thorsten; Burgdorf, Christof; Templin, Christian; Pellegrini, Costanza; Schneider, Simon; Kasel, Albert Markus; Kastrati, Adnan; Schunkert, Heribert; Hengstenberg, Christian

    2016-02-01

    Transcatheter aortic valve implantation is increasingly used in patients with aortic stenosis. Post-procedural intraventricular conduction abnormalities and permanent pacemaker implantations remain a serious concern. Recently, the Edwards SAPIEN 3 prosthesis has replaced the SAPIEN XT. We sought to determine the incidences of new-onset intraventricular conduction abnormalities and permanent pacemaker implantations by comparing the 2 devices. We analyzed the last consecutive 103 patients undergoing transcatheter aortic valve implantation with SAPIEN XT before SAPIEN 3 was used in the next 105 patients. To analyze permanent pacemaker implantations and new-onset intraventricular conduction abnormalities, patients with these conditions at baseline were excluded. Electrocardiograms were recorded at baseline, after the procedure, and before discharge. SAPIEN 3 was associated with higher device success (100% vs 92%; P=.005) and less paravalvular leakage (0% vs 7%; P<.001). The incidence of permanent pacemaker implantations was 12.6% (23 of 183) with no difference between the 2 groups (SAPIEN 3: 12.5% [12 of 96] vs SAPIEN XT: 12.6% [11 of 87]; P=.99). SAPIEN 3 was associated with a higher rate of new-onset intraventricular conduction abnormalities (49% vs 27%; P=.007) due to a higher rate of fascicular blocks (17% vs 5%; P=.021). There was no statistically significant difference in transient (29% [20 of 69] vs persistent 19% [12 of 64]; P=.168) left bundle branch blocks (28% [19 of 69] vs 17% [11 of 64]; P=.154) when SAPIEN 3 was compared with SAPIEN XT. We found a trend toward a higher rate of new-onset intraventricular conduction abnormalities with SAPIEN 3 compared with SAPIEN XT, although this did not result in a higher permanent pacemaker implantation rate. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Control of Insects in Slash Pine Cones with Trunk Implantations of Bidrin® Systemic Insecticide - First-Year Results

    Treesearch

    Edward P. Merkel

    1969-01-01

    Initial experiments with the implantation of the systemic insecticide Bidrin® into the trunks of slash pines in a seed production area resulted in various degrees of control of coneworms, Dioryctria spp., and the pine seed-worm, Laspeyresia anaronjada Miller, depending on dosage rates and time of application. When applied in early...

  19. The Bidirectional Transfer and Fetal Vascular Pressure Changes Due to the Presence of 125 I-Labeled Inhibin A in the ex-vivo Human Placental Model

    PubMed Central

    Ghetie, Victor

    2003-01-01

    Objective: The purpose of this study was to investigate the transport of inhibin A and to determine its effects on fetal vascular pressure at elevated levels in the human placenta using 125I -labeled synthetic glycoprotein. Methods: Synthetic inhibinAwas prepared and was shown to be consistent with the natural form by high-pressure liquid chromatography (HPLC) and molecular weight determination by gas-chromatography mass spectrometry. The standardized Na125I process yielded 125I -labeled inhibin A with a radioactivity of 106 cpm/μg. This compound was placed in the human placenta in maternal–fetal and fetal–maternal studies using antipyrine and 14C -labeled inulin as controls to determine the bidirectional transfer of the compound. Results: Maternal–fetal and fetal–maternal clearance indices were 0.045± 0.003 and 0, respectively. In eight placentas there was no evidence of vascular pressure changes due to the presence of up to 5000 pg of inhibin A. Conclusions: There is minimal maternal–fetal transfer and no detectable fetal–maternal transfer in normotensive and pregnancy-induced hypertensive placentas. In addition, there are no pressure changes in the fetal vascular system due to the clinically significant levels of inhibin A. PMID:14627215

  20. The perspective effects of various seed coating substances on rice seed variety Khao DAWK Mali 105 storability I: the case study of physiological properties.

    PubMed

    Thobunluepop, P; Pawelzik, E; Vearasilp, S

    2008-10-01

    This study aimed to evaluate the perspective changes of several physiological performances of rice seeds cv. KDML 105 which were coated with various seed coating substances [chemical fungicide, captan (CA) and biological coating polymers; chitosan-lignosulphonate polymer (CL) and eugenol incorporated into chitosan-lignosulphonate polymer (E + CL)] during storage (12 months). CA significantly increased seed moisture content and seed water activity through out the storage period. The qualities and viability of the seeds were seriously declined by this treatment. Moreover, CA inhibited the shoot and root development, seedling dry weight accumulation, delayed the seed germination and seedling growth rate. CA treated seeds were susceptible to stress conditions that declined the seed germination potential under cold, high moisture and temperature stress conditions. Nevertheless, CL and E + CL coating polymer could maintain seed storability, which significantly improved seed germination and seedling performances. These improvements were attributed to maintain the nutritive reserve and dehydrogenase activity in seeds. Moreover, the biological seed treatment stimulated the embryo growth and so speeding up the seedling emergence when compared untreated seeds.

  1. Spontaneous progression of peri-implantitis at different types of implants. An experimental study in dogs. I: clinical and radiographic observations.

    PubMed

    Albouy, Jean-Pierre; Abrahamsson, Ingemar; Persson, Leif G; Berglundh, Tord

    2008-10-01

    The aim of the present study was to analyze tissue reactions to plaque formation following ligature removal at commercially available implants exposed to experimental peri-implantitis. Six Labrador dogs about 1 year old were used. All mandibular premolars and the three anterior premolars in both sides of the maxilla were extracted. After 3 months four implants representing four different implant systems with different surface characteristics--implant group A (turned), B (TiOblast), C (sandblasted acid-etched; SLA) and D (TiUnite)--were placed in a randomized order in the right side of the mandible. Three months after implant installation experimental peri-implantitis was initiated by placement of ligatures in a submarginal position and plaque accumulation. At week 12, when about 40-50% of the supporting bone was lost, the ligatures were removed. During the subsequent 24-week period plaque accumulation continued. Radiographic and clinical examinations were performed during the 'active breakdown' period (plaque accumulation and ligatures) and the plaque accumulation period after ligature removal. The experiment was terminated at week 36. The bone loss that took place during the 'active breakdown' period varied between 3.5 and 4.6 mm. The additional bone loss that occurred during the plaque accumulation period after ligature removal was 1.84 (A), 1.72 (B), 1.55 (C) and 2.78 mm (D). Spontaneous progression of experimentally induced peri-implantitis occurred at implants with different geometry and surface characteristics. Progression was most pronounced at implants of type D (TiUnite surface).

  2. MicroRNA-125b protects against myocardial ischaemia/reperfusion injury via targeting p53-mediated apoptotic signalling and TRAF6

    PubMed Central

    Wang, Xiaohui; Ha, Tuanzhu; Zou, Jianghuan; Ren, Danyang; Liu, Li; Zhang, Xia; Kalbfleisch, John; Gao, Xiang; Williams, David; Li, Chuanfu

    2014-01-01

    Aims The present study examined the role of microRNA-125b (miR-125b) in myocardial ischaemia/reperfusion (I/R) injury. We constructed lentivirus-expressing miR-125b (LmiR-125b) and developed transgenic mice with overexpression of miR-125b. Methods and results LmiR-125b was transfected into mouse hearts through the right common carotid artery. Lentivirus vector (LmiR-Con) served as vector control. Untreated mice served as I/R control. Sham operation served as sham control. Seven days after transfection, the hearts were subjected to ischaemia (45 min) followed by reperfusion (4 h). Myocardial infarct size was analysed by 2,3,5-triphenyltetrazolium chloride staining. In separate experiments, hearts were subjected to ischaemia (45 min) followed by reperfusion for up to 7 days. Cardiac function was measured by echocardiography before, as well as 3 and 7 days after myocardial I/R. Increased expression of miR-125b significantly decreased I/R-induced myocardial infarct size by 60% and prevented I/R-induced decreases in ejection fraction (EF%) and fractional shortening (%FS). Transgenic mice with overexpression of miR-125b also showed the protection against myocardial I/R injury. Increased expression of miR-125b attenuated I/R-induced myocardial apoptosis and caspase-3/7 and -8 activities. Western blot showed that increased expression of miR-125b suppresses p53 and Bak1 expression in the myocardium. In addition, transfection of LmiR-125b decreased the levels of TNF receptor-associated factor 6 (TRAF6) and prevented I/R-induced NF-κB activation. Conclusion miR-125 protects the myocardium from I/R injury by preventing p53-mediated apoptotic signalling and suppressing TRAF6-mediated NF-κB activation. PMID:24576954

  3. Can Stable Isotope combined with Trace Element Analysis distinguish between pure and g.g.A. (protected geographical indication, P.G.I.) certified Pumpkin Seed Oils?

    NASA Astrophysics Data System (ADS)

    Meier-Augenstein, Wolfram; Kemp, Helen; Midwood, Andy

    2013-04-01

    Styrian Pumpkin Seed Oil is a premium single seed vegetable oil that is uniquely linked to the geographic region of Styria where it is grown and produced. In 1996, the strong regional ties of this typical Styrian speciality were recognised by the EU-Commission who declared "Styrian Pumpkin Seed Oil P.G.I." as a Protected Geographical Indication (article 5 VO(EWG) Nr. 2081/92). In 1998, more than 2,000 domestic pumpkin seed producers and 30 oil mills formed an association of Styrian pumpkin seed oil producers, which is now called the "Gemeinschaft Steirisches Kürbiskernöl g.g.A.". This producers' association was formed in order to protect the regionality and the high quality of Styrian Pumpkin Seed Oil P.G.I. Procedures implemented by this producers' association document every step in the process from pumpkin seeds to seed crushing in oil mills and finally bottling of Styrian Pumpkin Seed Oil P.G.I., keeping a contiguous record of all production steps including annual harvest amounts. This permits full traceability of every bottle of Styrian Pumpkin Seed Oil P.G.I from harvest to the finished, bottled products found on the shelf of delis and even supermarkets. Despite these efforts of the producers' association, there have been repeated claims of g.g.A. (P.G.I.) certified bottles of Styrian Pumpkin Seed Oil (PSO) having been analysed independently and shown to contain either mixtures of Styrian and non-Styrian PSO or no Styrian PSO at all. Since keeping records of annual harvest amounts of pumpkin seeds would make it very difficult for an "over-production" by mixing or substitution of alien PSO's to go unnoticed, we formed the hypothesis that the red-flagged bottles could have been counterfeits containing alien PSO with bottles sporting fake g.g.A. seals and fake serial numbers. An alternative hypothesis was that the chosen method of detection of allegedly misrepresented g.g.A. Styrian PSO resulted in a high number of false negatives thus incorrectly rejecting

  4. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.

    PubMed

    Quek, H C; Tan, Keson B; Nicholls, Jack I

    2008-01-01

    Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level

  5. Urethral toxicity after LDR brachytherapy: experience in Japan.

    PubMed

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer.

    PubMed

    Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-01-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D90 of 34Gy in 8.5Gy per fraction, and 145Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2Gy per fraction, EQD2) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The Dmean (EQD2) of rectum decreased 22.36Gy in HDR and 17.01Gy in LDR from 30.24Gy in VMAT, respectively. The Dmean (EQD2) of bladder decreased 6.91Gy in HDR and 2.53Gy in LDR from 13.46Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD2) was 80.26, 70.23, and 104.91Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  7. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR andmore » LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.« less

  8. SEEDS Moving Group Status Update

    NASA Technical Reports Server (NTRS)

    McElwain, Michael

    2011-01-01

    I will summarize the current status of the SEEDS Moving Group category and describe the importance of this sub-sample for the entire SEEDS survey. This presentation will include analysis of the sensitivity for the Moving Groups with general a comparison to other the other sub-categories. I will discuss the future impact of the Subaru SCExAO system for these targets and the advantage of using a specialized integral field spectrograph. Finally, I will present the impact of a pupil grid mask in order to produce fiducial spots in the focal plane that can be used for both photometry and astrometry.

  9. Effect of Ar Ion Beam Implantation on Morphological and Physiological Characteristics of Liquorice (Glycyrrhiza uralensis Fisch) Under Short-Term Artificial Drought Conditions

    NASA Astrophysics Data System (ADS)

    Zhang, Xiangsheng; Wu, Lijun; Yu, Lixiang; Wei, Shenglin; Liu, Jingnan; Yu, Zengliang

    2007-04-01

    Ar+ ion beam with low energy of 30 keV was implanted into liquorice (Glycyrrhiza uralensis Fisch) seeds at the doses of 0, 600, 900 and 1200 × (2.6 × 1013) ions/cm2, respectively. The seeds were sowed in pots and after one month the plants were subjected to different drought conditions for two months. Then the plants' morphological and physiological characteristics, anti-oxidation enzymes and levels of endogenous hormones were investigated. The results showed that ion implantation at a proper dose can greatly enhance the liquorice seedlings' resistance against drought stress.

  10. Contagious Deposition of Seeds in Spider Monkeys' Sleeping Trees Limits Effective Seed Dispersal in Fragmented Landscapes

    PubMed Central

    González-Zamora, Arturo; Arroyo-Rodríguez, Víctor; Escobar, Federico; Rös, Matthias; Oyama, Ken; Ibarra-Manríquez, Guillermo; Stoner, Kathryn E.; Chapman, Colin A.

    2014-01-01

    The repeated use of sleeping sites by frugivorous vertebrates promotes the deposition and aggregation of copious amounts of seeds in these sites. This spatially contagious pattern of seed deposition has key implications for seed dispersal, particularly because such patterns can persist through recruitment. Assessing the seed rain patterns in sleeping sites thus represents a fundamental step in understanding the spatial structure and regeneration of plant assemblages. We evaluated the seed rain produced by spider monkeys (Ateles geoffroyi) in latrines located beneath 60 sleeping trees in two continuous forest sites (CFS) and three forest fragments (FF) in the Lacandona rainforest, Mexico. We tested for differences among latrines, among sites, and between forest conditions in the abundance, diversity (α-, β- and, γ-components) and evenness of seed assemblages. We recorded 45,919 seeds ≥5 mm (in length) from 68 species. The abundance of seeds was 1.7 times higher in FF than in CFS, particularly because of the dominance of a few plant species. As a consequence, community evenness tended to be lower within FF. β-diversity of common and dominant species was two times greater among FF than between CFS. Although mean α-diversity per latrine did not differ among sites, the greater β-diversity among latrines in CFS increased γ-diversity in these sites, particularly when considering common and dominant species. Our results support the hypothesis that fruit scarcity in FF can ‘force’ spider monkeys to deplete the available fruit patches more intensively than in CFS. This feeding strategy can limit the effectiveness of spider monkeys as seed dispersers in FF, because (i) it can limit the number of seed dispersers visiting such fruit patches; (ii) it increases seed dispersal limitation; and (iii) it can contribute to the floristic homogenization (i.e., reduced β-diversity among latrines) in fragmented landscapes. PMID:24586705

  11. Autoradiographic evidence for two classes of mu opioid binding sites in rat brain using (/sup 125/I)FK33824

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothman, R.B.; Jacobson, A.E.; Rice, K.C.

    1987-11-01

    Previous studies demonstrated that pretreatment of brain membranes with the irreversible mu antagonist, beta-funaltrexamine (beta-FNA), partially eliminated mu binding sites (25,35), consistent with the existence of two mu binding sites distinguished by beta-FNA. This paper tests the hypothesis that the FNA-sensitive and FNA-insensitive mu binding sites have different anatomical distributions in rat brain. Prior to autoradiographic visualization of mu binding sites, (/sup 3/H)oxymorphone, (/sup 3/H)D-ala2-MePhe4, Gly-ol5-enkephalin (DAGO), and (/sup 125/I)D-ala2-Me-Phe4-met(o)-ol)enkephalin (FK33824) were shown to selectively label mu binding sites using slide mounted sections of molded minced rat brain. As found using membranes, beta-FNA eliminated only a portion of mu bindingmore » sites. Autoradiographic visualization of mu binding sites using the mu-selective ligand (/sup 125/I)FK33824 in control and FNA-treated sections of rat brain demonstrated that the proportion of mu binding sites sensitive to beta-FNA varied across regions of the brain, particularly the dorsal thalamus, ventrobasal complex and the hypothalamus, providing anatomical data supporting the existence of two classes of mu binding sites in rat brain.« less

  12. Implantation of Vascular Grafts Lined with Genetically Modified Endothelial Cells

    NASA Astrophysics Data System (ADS)

    Wilson, James M.; Birinyi, Louis K.; Salomon, Robert N.; Libby, Peter; Callow, Allan D.; Mulligan, Richard C.

    1989-06-01

    The possibility of using the vascular endothelial cell as a target for gene replacement therapy was explored. Recombinant retroviruses were used to transduce the lacZ gene into endothelial cells harvested from mongrel dogs. Prosthetic vascular grafts seeded with the genetically modified cells were implanted as carotid interposition grafts into the dogs from which the original cells were harvested. Analysis of the graft 5 weeks after implantation revealed genetically modified endothelial cells lining the luminal surface of the graft. This technology could be used in the treatment of atherosclerosis disease and the design of new drug delivery systems.

  13. Recruitment of host's progenitor cells to sites of human amniotic fluid stem cells implantation.

    PubMed

    Mirabella, Teodelinda; Poggi, Alessandro; Scaranari, Monica; Mogni, Massimo; Lituania, Mario; Baldo, Chiara; Cancedda, Ranieri; Gentili, Chiara

    2011-06-01

    The amniotic fluid is a new source of multipotent stem cells with a therapeutic potential for human diseases. Cultured at low cell density, human amniotic fluid stem cells (hAFSCs) were still able to generate colony-forming unit-fibroblast (CFU-F) after 60 doublings, thus confirming their staminal nature. Moreover, after extensive in vitro cell expansion hAFSCs maintained a stable karyotype. The expression of genes, such as SSEA-4, SOX2 and OCT3/4 was confirmed at early and later culture stage. Also, hAFSCs showed bright expression of mesenchymal lineage markers and immunoregulatory properties. hAFSCs, seeded onto hydroxyapatite scaffolds and subcutaneously implanted in nude mice, played a pivotal role in mounting a response resulting in the recruitment of host's progenitor cells forming tissues of mesodermal origin such as fat, muscle, fibrous tissue and immature bone. Implanted hAFSCs migrated from the scaffold to the skin overlying implant site but not to other organs. Given their in vivo: (i) recruitment of host progenitor cells, (ii) homing towards injured sites and (iii) multipotentiality in tissue repair, hAFSCs are a very appealing reserve of stem cells potentially useful for clinical application in regenerative medicine. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1983-07-15

    The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. EX) 1473 MrION Of" I POV GS IS O&SOLETE...10 Clinical Examples of Baboon Dental Implants . . . . . . . . . . . 12 Histologic Analysis of the Bone-Implant Interface . . . . . . . . 16...Aluminum Oxide Dental Implant . . . . . . . . . . 2 Figure 2. Clinical Photograph of A29 and A30 in Baboon 469 at Necropsy

  15. Lotus seed epicarp extract as potential antioxidant and anti-obesity additive in Chinese Cantonese Sausage.

    PubMed

    Qi, Suijian; Zhou, Delong

    2013-02-01

    The antioxidative activities of a lotus seed epicarp extract in different concentrations (6.25, 12.5, 25, 50 and 100 μg.mL(-1)) in pork homogenates representative of Chinese Cantonese Sausage were evaluated using three methods: thiobarbituric acid-reactive substances (TBARS) values, peroxide values (POVs) and acid values (AVs). Also the cytotoxic and anti-obesity effects of the lotus seed epicarp extracts were evaluated using an in vitro 3T3-L1 preadipocyte cell model. Results showed that the lotus seed epicarp extracts were non-toxic and effective in inhibiting preadipocyte differentiation. Supplementation of pork homogenate with lotus seed epicarp extracts was effective in retarding lipid oxidation. Moreover, the antioxidative and preadipocyte differentiation inhibition effects of the lotus seed epicarp extracts were dose-dependent. Thus, the lotus seed epicarp extract might be a good candidate as an antioxidant and anti-obesity natural additive in Chinese Cantonese Sausage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Real-time photoacoustic imaging of prostate brachytherapy seeds using a clinical ultrasound system.

    PubMed

    Kuo, Nathanael; Kang, Hyun Jae; Song, Danny Y; Kang, Jin U; Boctor, Emad M

    2012-06-01

    Prostate brachytherapy is a popular prostate cancer treatment option that involves the permanent implantation of radioactive seeds into the prostate. However, contemporary brachytherapy procedure is limited by the lack of an imaging system that can provide real-time seed-position feedback. While many other imaging systems have been proposed, photoacoustic imaging has emerged as a potential ideal modality to address this need, since it could easily be incorporated into the current ultrasound system used in the operating room. We present such a photoacoustic imaging system built around a clinical ultrasound system to achieve the task of visualizing and localizing seeds. We performed several experiments to analyze the effects of various parameters on the appearance of brachytherapy seeds in photoacoustic images. We also imaged multiple seeds in an ex vivo dog prostate phantom to demonstrate the possibility of using this system in a clinical setting. Although still in its infancy, these initial results of a photoacoustic imaging system for the application of prostate brachytherapy seed localization are highly promising.

  17. Seed source, seed traits, and frugivore habits: Implications for dispersal quality of two sympatric primates.

    PubMed

    Benítez-Malvido, Julieta; González-Di Pierro, Ana Ma; Lombera, Rafael; Guillén, Susana; Estrada, Alejandro

    2014-06-01

    • Premise of the study: Frugivore selection of fruits and treatment of seeds together with seed deposition site are crucial for the population dynamics of vertebrate-dispersed plants. However, frugivore species may influence dispersal quality differently even when feeding on the same fruit species and, while animals disperse some seeds, others simply fall beneath the parent plant.• Methods: In southern Mexico, we investigated to see if within-species seed traits (i.e., length, width, weight, and volume) and germination success differed according to seed source. For five tropical tree species we obtained ingested seeds from two sources, howler monkey (Alouatta pigra) and spider monkey (Ateles geoffroyi) feces; and noningested seeds from two sources, the ground and tree crowns (with predispersed seeds used as control).• Key results: A principal components' analysis showed that traits of seeds ingested by howler monkeys differed from other sources while seeds ingested by spider monkeys were similar to noningested seeds. Howlers consumed on average the larger seeds in Ampelocera hottlei, Brosimum lactescens, and Dialium guianense. Both primate species consumed the smaller seeds in Spondias mombin, while no seed trait differences among seed sources were found in Spondias radlkoferi. For all five tree species, germination rate was greatest for seeds ingested by howler monkeys.• Conclusions: For the studied plant species, seed ingestion by howler monkeys confers higher dispersal quality than ingestion by spider monkeys or nondispersal. Dispersal services of both primate species, however, are not redundant and may contribute to germination heterogeneity within plant populations in tropical forests. © 2014 Botanical Society of America, Inc.

  18. Implants for elderly patients.

    PubMed

    Schimmel, Martin; Müller, Frauke; Suter, Valérie; Buser, Daniel

    2017-02-01

    In the developed world, the large birth cohorts of the so-called baby boomer generation have arrived in medical and dental practices. Often, elderly patients are 'young-old' baby boomers in whom partial edentulism is the predominant indication for implant therapy. However, the generation 85+ years of age represents a new challenge for the dental profession, as their lives are frequently dominated by dependency, multimorbidity and frailty. In geriatric implant dentistry, treatment planning is highly individualized, as interindividual differences become more pronounced with age. Nevertheless, there are four typical indications for implant therapy: (i) avoidance of removable partial prostheses; (ii) preservation of existing removable partial prostheses; (iii) stabilization of Kennedy Class I removable partial prostheses; and (iv) stabilization of complete prostheses. From a surgical point of view, two very important aspects must be considered when planning implant surgery in elderly patients: first, the consistent strive to minimize morbidity; and, second, the fact that coexisting medical risk factors are significantly more common in elderly patients. Modern three-dimensional cone beam computed tomography imaging is often indicated in order to plan minimally invasive implant surgery. Computer-assisted implant surgery might allow flapless implant surgery, which offers a low level of postoperative morbidity and a minimal risk of postsurgical bleeding. Short and reduced-diameter implants are now utilized much more often than a decade ago. Two-stage surgical procedures should be avoided in elderly patients. Implant restorations for elderly patients should be designed so that they can be modified to become low-maintenance prostheses, or even be removed, as a strategy to facilitate oral hygiene and comfort in the final stage of life. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    PubMed

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  20. MicroRNA-125b protects against myocardial ischaemia/reperfusion injury via targeting p53-mediated apoptotic signalling and TRAF6.

    PubMed

    Wang, Xiaohui; Ha, Tuanzhu; Zou, Jianghuan; Ren, Danyang; Liu, Li; Zhang, Xia; Kalbfleisch, John; Gao, Xiang; Williams, David; Li, Chuanfu

    2014-06-01

    The present study examined the role of microRNA-125b (miR-125b) in myocardial ischaemia/reperfusion (I/R) injury. We constructed lentivirus-expressing miR-125b (LmiR-125b) and developed transgenic mice with overexpression of miR-125b. LmiR-125b was transfected into mouse hearts through the right common carotid artery. Lentivirus vector (LmiR-Con) served as vector control. Untreated mice served as I/R control. Sham operation served as sham control. Seven days after transfection, the hearts were subjected to ischaemia (45 min) followed by reperfusion (4 h). Myocardial infarct size was analysed by 2,3,5-triphenyltetrazolium chloride staining. In separate experiments, hearts were subjected to ischaemia (45 min) followed by reperfusion for up to 7 days. Cardiac function was measured by echocardiography before, as well as 3 and 7 days after myocardial I/R. Increased expression of miR-125b significantly decreased I/R-induced myocardial infarct size by 60% and prevented I/R-induced decreases in ejection fraction (EF%) and fractional shortening (%FS). Transgenic mice with overexpression of miR-125b also showed the protection against myocardial I/R injury. Increased expression of miR-125b attenuated I/R-induced myocardial apoptosis and caspase-3/7 and -8 activities. Western blot showed that increased expression of miR-125b suppresses p53 and Bak1 expression in the myocardium. In addition, transfection of LmiR-125b decreased the levels of TNF receptor-associated factor 6 (TRAF6) and prevented I/R-induced NF-κB activation. miR-125 protects the myocardium from I/R injury by preventing p53-mediated apoptotic signalling and suppressing TRAF6-mediated NF-κB activation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  1. The potential of the second sight system bionic eye implant for partial sight restoration.

    PubMed

    Luo, Yvonne Hsu-Lin; Fukushige, Eka; Da Cruz, Lyndon

    2016-07-01

    Second Sight System bionic eye implant, a commercially available visual prosthesis developed by Second Sight Medical Products, has been implanted in over 125 patients with outer retinal dystrophies such as retinitis pigmentosa. The system has gained regulatory approval in both the USA and Europe, and aims to restore vision by electrical stimulation of the nerve cells of the inner retina. In this review, we present the safety profile of this implant from the international clinical trial and discuss the nature and levels of improvement in visual function achieved by patients implanted with the system. Expert commentary: Future developments for the system will be explored following the discussion of the current usefulness of the device, its limitation as and the areas in which further development is necessary.

  2. Poster — Thur Eve — 41: Considerations for Patients with Permanently Implant Radioactive Sources Requiring Unrelated Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basran, P. S; Beckham, WA; Baxter, P

    Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patientmore » and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.« less

  3. Corridors cause differential seed predation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrock, John L.; Damschen, Ellen I.

    2005-06-01

    Orrock, John, L., and Ellen I. Damschen. 2005. Corridors cause differential seed predation. Ecol. Apps. 15(3):793-798. Abstract. Corridors that connect disjunct populations are heavily debated in conservation, largely because the effects of corridors have rarely been evaluated by replicated, large-scale studies. Using large-scale experimental landscapes, we found that, in addition to documented positive effects, corridors also have negative impacts on bird-dispersed plants by affecting seed predation, and that overall predation is a function of the seeds primary consumer (rodents or arthropods). Both large-seeded Prunus serotina and small-seeded Rubus allegheniensis experienced greater predation in connected patches. However, P. serotina experienced significantlymore » less seed predation compared to R. allegheniensis in unconnected patches, due to decreased impacts of rodent seed predators on this large-seeded species. Viewed in light of previous evidence that corridors have beneficial impacts by increasing pollination and seed dispersal, this work demonstrates that corridors may have both positive and negative effects for the same plant species at different life stages. Moreover, these effects may differentially affect plant species within the same community: seeds primarily consumed by rodents suffer less predation in unconnected patches. By shifting the impact of rodent and arthropod seed predators, corridors constructed for plant conservation could lead to shifts in the seed bank.« less

  4. Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses

    PubMed Central

    Sohn, Byoung-Sup; Heo, Seong-Joo; Koak, Jai-Young; Kim, Seong-Kyun

    2011-01-01

    PURPOSE This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS The mean strain values (MSV) for the working sides were 151.83 µε, 176.23 µε, and 131.07 µε for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 µε, 72.64 µε, and 98.93 µε for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01). PMID:21503186

  5. SU-F-T-02: Estimation of Radiobiological Doses (BED and EQD2) of Single Fraction Electronic Brachytherapy That Equivalent to I-125 Eye Plaque: By Using Linear-Quadratic and Universal Survival Curve Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Y; Waldron, T; Pennington, E

    Purpose: To test the radiobiological impact of hypofractionated choroidal melanoma brachytherapy, we calculated single fraction equivalent doses (SFED) of the tumor that equivalent to 85 Gy of I125-BT for 20 patients. Corresponding organs-at-risks (OARs) doses were estimated. Methods: Twenty patients treated with I125-BT were retrospectively examined. The tumor SFED values were calculated from tumor BED using a conventional linear-quadratic (L-Q) model and an universal survival curve (USC). The opposite retina (α/β = 2.58), macula (2.58), optic disc (1.75), and lens (1.2) were examined. The % doses of OARs over tumor doses were assumed to be the same as for amore » single fraction delivery. The OAR SFED values were converted into BED and equivalent dose in 2 Gy fraction (EQD2) by using both L-Q and USC models, then compared to I125-BT. Results: The USC-based BED and EQD2 doses of the macula, optic disc, and the lens were on average 118 ± 46% (p < 0.0527), 126 ± 43% (p < 0.0354), and 112 ± 32% (p < 0.0265) higher than those of I125-BT, respectively. The BED and EQD2 doses of the opposite retina were 52 ± 9% lower than I125-BT. The tumor SFED values were 25.2 ± 3.3 Gy and 29.1 ± 2.5 Gy when using USC and LQ models which can be delivered within 1 hour. All BED and EQD2 values using L-Q model were significantly larger when compared to the USC model (p < 0.0274) due to its large single fraction size (> 14 Gy). Conclusion: The estimated single fraction doses were feasible to be delivered within 1 hour using a high dose rate source such as electronic brachytherapy (eBT). However, the estimated OAR doses using eBT were 112 ∼ 118% higher than when using the I125-BT technique. Continued exploration of alternative dose rate or fractionation schedules should be followed.« less

  6. Factors constraining the benefit to speech understanding of combining information from low-frequency hearing and a cochlear implant.

    PubMed

    Dorman, Michael F; Cook, Sarah; Spahr, Anthony; Zhang, Ting; Loiselle, Louise; Schramm, David; Whittingham, JoAnne; Gifford, Rene

    2015-04-01

    Many studies have documented the benefits to speech understanding when cochlear implant (CI) patients can access low-frequency acoustic information from the ear opposite the implant. In this study we assessed the role of three factors in determining the magnitude of bimodal benefit - (i) the level of CI-only performance, (ii) the magnitude of the hearing loss in the ear with low-frequency acoustic hearing and (iii) the type of test material. The patients had low-frequency PTAs (average of 125, 250 and 500 Hz) varying over a large range (<30 dB HL to >70 dB HL) in the ear contralateral to the implant. The patients were tested with (i) CNC words presented in quiet (n = 105) (ii) AzBio sentences presented in quiet (n = 102), (iii) AzBio sentences in noise at +10 dB signal-to-noise ratio (SNR) (n = 69), and (iv) AzBio sentences at +5 dB SNR (n = 64). We find maximum bimodal benefit when (i) CI scores are less than 60 percent correct, (ii) hearing loss is less than 60 dB HL in low-frequencies and (iii) the test material is sentences presented against a noise background. When these criteria are met, some bimodal patients can gain 40-60 percentage points in performance relative to performance with a CI. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Increased hs-CRP and decreased 1,25-dihydroxyvitamin D are associated with increased left ventricle lead threshold.

    PubMed

    Gözübüyük, Gökhan; Koç, Mevlüt; Kaypaklı, Onur; Şahin, Durmuş Yıldıray

    2016-11-01

    There are not enough data about threshold changes in patients with CRT. In this study, we aimed to investigate frequency of significant threshold increase of left ventricle lead and to determine clinical, demographic, medical and laboratory parameters that associated with threshold increase in CRT implanted patients. We included CRT implanted 200 patients (124 males, 76 females; mean age 65.8 ± 10.3 years) to this study. Basal and third month LV R wave amplitude, electrode impedance, and threshold values were recorded. Threshold increase was accepted as ≥0.1 V and significant increase as >1 V. Patients were divided into two groups: increased threshold and non-increased threshold for LV lead. Number of patients with increased LV threshold was 68 (37.6 %). Furthermore, 8 % of patients had severe increase (≥1 V) in LV threshold. We observed that serum levels of hs-CRP and 1,25 (OH)2 vitamin D were independently associated with increased LV threshold. We showed that 1 mg/dl increase in hs-CRP and the 1 mg/dl decrease in vitamin D are associated with 25.3 and 4.5 % increase in the odds of increased LV threshold, respectively. Increased hs-CRP and decreased 1,25 (OH)2 vitamin D are the strongest predictors of increased LV lead thresholds. We suggest that hs-CRP and 1,25 (OH)2 vitamin D may be used as markers to predict and follow the patients with increased thresholds. It may be useful to finalize CRT procedure with more appropriate basal threshold in patients with high serum hs-CRP and low 1,25 (OH)2 vitamin D levels.

  8. Detection and correction of patient movement in prostate brachytherapy seed reconstruction

    NASA Astrophysics Data System (ADS)

    Lam, Steve T.; Cho, Paul S.; Marks, Robert J., II; Narayanan, Sreeram

    2005-05-01

    Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be determined. However, when local anaesthesia is used for prostate brachytherapy, the patient movement during fluoroscopy image capture becomes a practical problem. If uncorrected, the errors introduced by patient motion between image captures would cause seed mismatches. Subsequently, the seed reconstruction algorithm would either fail to reconstruct or yield erroneous results. We have developed an algorithm that permits detection and correction of patient movement that may occur between fluoroscopy image captures. The patient movement is decomposed into translational shifts along the tabletop and rotation about an axis perpendicular to the tabletop. The property of spatial invariance of the co-planar imaging geometry is used for lateral movement correction. Cranio-caudal movement is corrected by analysing the perspective invariance along the x-ray axis. Rotation is estimated by an iterative method. The method can detect and correct for the range of patient movement commonly seen in the clinical environment. The algorithm has been implemented for routine clinical use as the preprocessing step for seed reconstruction.

  9. Use of subdermal contraceptive implants in a community-based family planning program. Experience after two years.

    PubMed

    Mittelmark, M B; Hansen, W B; Shiferaw, B; Bradham, D D

    1995-10-01

    In North Carolina, the Rutherford County Family Planning Council obtained funds from a special grant for levonorgestrel implants for women not eligible for medical assistance benefits. The Council approved the following approaches to promoting responsible sexual behavior and preventing unwanted pregnancy: creation of an interagency council to monitor the program, education in the schools on responsible sexual behavior, establishment of an information-sharing network for social service agencies, and expanded, low-cost or free family planning services. During 1992-1993, clinicians at the county health department and in private practices inserted implants in 287 women aged 13-37 living mainly in Rutherford County but also in McDowell and Polk counties. A survey was also conducted in the public high school to obtain self-assessment and information about family planning from female adolescents. Age distribution of the acceptors of the contraceptive implants was 40% for 13-19 year olds (the initiative's target group), 34% for 21-25 year olds, and 32% for 18-20 year olds (32%). The two-year insertion rate for women aged 10-19 was 17.3/1000 compared to 20.8/1000 for women aged 20-29. The implantation rate was greatest among 18-25 year olds and lowest among women aged 26 and older. The method of payment for implantation was medical assistance in 69% of cases and a philanthropic foundation for women not eligible for medical assistance in 29% of cases. 8% had the implants removed during the study period. The leading reason for removal was psychological distress (25%), followed by headaches (20.8%), desire to conceive (16.7%), bleeding (12.5%), and medical contraindication (12.5%). The interval between implantation and removal ranged from less than 3 months to more than 12 months. 2.3% of the female high school students used implants. Among the 596 students who were sexually active, 4.2% used implants, 1.85% used a diaphragm, 27.5% used condoms, and 15% used oral

  10. Influence of implant inclination associated with mandibular class I removable partial denture.

    PubMed

    de Freitas Santos, Ciandrus Moraes; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos; de Moraes, Sandra Lúcia Dantas; Falcón-Antenucci, Rosse Mary

    2011-03-01

    The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.

  11. [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

    PubMed

    Beckmann, J; Steinert, A; Zilkens, C; Zeh, A; Schnurr, C; Schmitt-Sody, M; Gebauer, M

    2016-04-01

    Knee arthroplasty is a successful standard procedure in orthopedic surgery; however, approximately 20 % of patients are dissatisfied with the clinical results as they suffer pain and can no longer achieve the presurgery level of activity. According to the literature the reasons are inexact fitting of the prosthesis or too few anatomically formed implants resulting in less physiological kinematics of the knee joint. Reducing the number of dissatisfied patients and the corresponding number of revisions is an important goal considering the increasing need for artificial joints. In this context, patient-specific knee implants are an obvious alternative to conventional implants. For the first time implants are now matched to the individual bone and not vice versa to achieve the best possible individual situation and geometry and more structures (e.g. ligaments and bone) are preserved or only those structures are replaced which were actually destroyed by arthrosis. According to the authors view, this represents an optimal and pioneering addition to conventional implants. Patient-specific implants and the instruments needed for correct alignment and fitting can be manufactured by virtual 3D reconstruction and 3D printing based on computed tomography (CT) scans. The portfolio covers medial as well as lateral unicondylar implants, medial as well as lateral bicompartmental implants (femorotibial and patellofemoral compartments) and cruciate ligament-preserving as well as cruciate ligament-substituting total knee replacements; however, it must be explicitly emphasized that the literature is sparse and no long-term data are available.

  12. Preventive Effect of Three Pomegranate (Punica granatum L.) Seeds Fractions on Cerulein-Induced Acute Pancreatitis in Mice

    PubMed Central

    Minaiyan, Mohsen; Zolfaghari, Behzd; Taheri, Diana; Gomarian, Mahdi

    2014-01-01

    Background: Acute pancreatitis (AP) refers to afflicted inflammation of pancreas with unfavorable adverse effects and developed multiple organ failures. Unfortunately, there is not a certain therapeutic method for this disease. Oxidative stress has a serious role in the pathogenesis of AP. Thus, decreasing of oxidative stress may prevent induction and progression of AP. Punica granatum L. has been extensively used in traditional medicine and possesses various active biological elements. Due to antioxidant and anti-inflammatory properties of pomegranate, it could be considered as a good candidate alternative medicine with beneficial effects on AP. In this study, we decided to study the protective effect of three fractions of pomegranate seeds on cerulein-induced AP. Methods: AP was induced in male Syrian mice by five intraperitoneal (i.p.) injection of cerulein (50 μg/kg) with 1 h intervals. Treatments with pomegranate freeze-dried powder (PFDP) and hydroalcoholic pomegranate seeds extract (PSE) at doses of 125, 250, 500 mg/kg (i.p.) were started 30 min before pancreatitis induction. Pomegranate seed oil fraction (PSOF) was orally administered (50, 100, 200 μL/kg) and continued for 10 days. Pancreatic tissue was evaluated for histopathological parameters and pancreatic myeloperoxidase (MPO) activity as well as lipase and amylase levels were measured in plasma. Results: The higher doses of three fractions (250 and 500 mg/kg for PFDP and PSE and doses of 100, 200 μL/kg for PSOF) significantly reduced amylase and lipase activity in serum (at least P < 0.01), pancreatic MPO activity (P < 0.001), edema, leukocyte infiltration and vacuolization in comparison to the control group (P < 0.05). Conclusions: These results propose that pomegranate seeds fractions can prevent and/or treat the AP. PMID:24829726

  13. Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation

    PubMed Central

    Amoush, Ahmad; Wilkinson, Douglas A.

    2015-01-01

    This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantage  125I seeds. In addition, the dosimetry parameters Λ, gL(r), and F(r,θ) were calculated for the IsoAid Advantage model IAI‐125125I seed and benchmarked against published data. Bebig Plaque Simulator (PS) v5.74 was used to calculate the central axis dose based on the AAPM Updated Task Group 43 (TG‐43U1) dose formalism. The calculated central axis dose from MC and PS was then compared. When the MC dosimetry parameters for the IsoAid Advantage  125I seed were compared with the consensus values, Λ agreed with the consensus value to within 2.3%. However, much larger differences were found between MC calculated gL(r) and F(r,θ) and the consensus values. The differences between MC‐calculated dosimetry parameters are much smaller when compared with recently published data. The differences between the calculated central axis absolute dose from MC and PS ranged from 5% to 10% for distances between 1 and 12 mm from the outer scleral surface. When the dosimetry parameters for the  125I seed from this study were used in PS, the calculated absolute central axis dose differences were reduced by 2.3% from depths of 4 to 12 mm from the outer scleral surface. We conclude that PS adequately models the central dose profile of this plaque using its defaults for the IsoAid model IAI‐125 at distances of 1 to 7 mm from the outer scleral surface. However, improved dose accuracy can be obtained by using updated dosimetry parameters for the IsoAid model IAI‐125125I seed. PACS number: 87.55.K‐ PMID:26699577

  14. Soil moisture and fungi affect seed survival in California grassland annual plants.

    PubMed

    Mordecai, Erin A

    2012-01-01

    Survival of seeds in the seed bank is important for the population dynamics of many plant species, yet the environmental factors that control seed survival at a landscape level remain poorly understood. These factors may include soil moisture, vegetation cover, soil type, and soil pathogens. Because many soil fungi respond to moisture and host species, fungi may mediate environmental drivers of seed survival. Here, I measure patterns of seed survival in California annual grassland plants across 15 species in three experiments. First, I surveyed seed survival for eight species at 18 grasslands and coastal sage scrub sites ranging across coastal and inland Santa Barbara County, California. Species differed in seed survival, and soil moisture and geographic location had the strongest influence on survival. Grasslands had higher survival than coastal sage scrub sites for some species. Second, I used a fungicide addition and exotic grass thatch removal experiment in the field to tease apart the relative impact of fungi, thatch, and their interaction in an invaded grassland. Seed survival was lower in the winter (wet season) than in the summer (dry season), but fungicide improved winter survival. Seed survival varied between species but did not depend on thatch. Third, I manipulated water and fungicide in the laboratory to directly examine the relationship between water, fungi, and survival. Seed survival declined from dry to single watered to continuously watered treatments. Fungicide slightly improved seed survival when seeds were watered once but not continually. Together, these experiments demonstrate an important role of soil moisture, potentially mediated by fungal pathogens, in driving seed survival.

  15. Interferon-τ increases BoLA-I for implantation during early pregnancy in dairy cows.

    PubMed

    Zhu, Zhe; Li, Binbin; Wu, Yue; Wang, Xiao; Deng, GanZhen

    2017-11-10

    Interferon-τ (IFN-τ) signals pregnancy recognition in ruminants. We investigated the effects of IFN-τ produced by embryo trophoblastic cells (ETCs) on expression of bovine leukocyte antigen-I (BoLA-I), a bovine analogue of human MHC-I, in endometrial luminal epithelial cells (EECs) during early pregnancy in dairy cows. Expression of IFN-τ and BoLA-I was increased in endometrial tissues during early pregnancy. Expression of the anti-inflammatory cytokine IL-10 was increased in endometrial tissues, while expression of the pro-inflammatory cytokine IL-6 was decreased, indicating immunosuppression. Progesterone increased IFN-τ expression in EECs. IFN-τ increased p-STAT1 and p-STAT3 levels in EECs, but reduced TRAF3 levels. In addition, IFN-τ increased expression of BoLA-I and IL-10, but decreased expression of IL-6 in EECs. These results indicate that IFN-τ enables stable implantation in dairy cows by increasing expression of BoLA-I, and by immunosuppression mediated by increased IL-10 and decreased IL-6 expression.

  16. Interferon-τ increases BoLA-I for implantation during early pregnancy in dairy cows

    PubMed Central

    Zhu, Zhe; Li, Binbin; Wu, Yue; Wang, Xiao; Deng, GanZhen

    2017-01-01

    Interferon-τ (IFN-τ) signals pregnancy recognition in ruminants. We investigated the effects of IFN-τ produced by embryo trophoblastic cells (ETCs) on expression of bovine leukocyte antigen-I (BoLA-I), a bovine analogue of human MHC-I, in endometrial luminal epithelial cells (EECs) during early pregnancy in dairy cows. Expression of IFN-τ and BoLA-I was increased in endometrial tissues during early pregnancy. Expression of the anti-inflammatory cytokine IL-10 was increased in endometrial tissues, while expression of the pro-inflammatory cytokine IL-6 was decreased, indicating immunosuppression. Progesterone increased IFN-τ expression in EECs. IFN-τ increased p-STAT1 and p-STAT3 levels in EECs, but reduced TRAF3 levels. In addition, IFN-τ increased expression of BoLA-I and IL-10, but decreased expression of IL-6 in EECs. These results indicate that IFN-τ enables stable implantation in dairy cows by increasing expression of BoLA-I, and by immunosuppression mediated by increased IL-10 and decreased IL-6 expression. PMID:29221114

  17. Hip and knee effects after implantation of a drop foot stimulator.

    PubMed

    Yao, Daiwei; Lahner, Matthias; Jakubowitz, Eike; Thomann, Anna; Ettinger, Sarah; Noll, Yvonne; Stukenborg-Colsman, Christina; Daniilidis, Kiriakos

    2017-01-01

    An active ankle dorsiflexion is essential for a proper gait pattern. If there is a failure of the foot lifting, considerable impairments occur. The therapeutic effect of an implantable peroneus nerve stimulator (iPNS) for the ankle dorsiflexion is already approved by recent studies. However, possible affection for knee and hip motion after implantation of an iPNS is not well described. The objective of this retrospective study was to examine with a patient cohort whether the use of iPNS induces a lower-extremity flexion withdrawal response in the form of an increased knee and hip flexion during swing phase. Eighteen subjects (12 m/6 w) treated with an iPNS (ActiGait®, Otto Bock, Duderstadt, Germany) were examined in knee and hip motion by gait analysis with motion capture system (Vicon Motion System Ltd®, Oxford, UK) and Plug-in-Gait model after a mean follow up from 12.5 months. The data were evaluated and compared in activated and deactivated iPNS. Only little changes could be documented, as a slight average improvement in peak knee flexion during stand phase from 1.0° to 2.5° and peak hip flexion in stance from 3.1° to 2.1° In contrast, peak knee flexion during swing appeared similar (25.3° to 25.7°) same as peak hip flexion during swing. In comparison with the healthy extremity, a more symmetric course of the knee flexion during stand phase could be shown. No statistical significant improvements or changes in hip and knee joint could be shown in this study. Only a more symmetric knee flexion during stand phase and a less hip flexion during stand phase might be hints for a positive affection of iPNS for knee and hip joint. It seems that the positive effect of iPNS is only based on the improvement in ankle dorsiflexion according to the recent literature.

  18. EMISSION OF VOLATILE COMPOUNDS BY SEEDS UNDER DIFFERENT ENVIRONMENTAL CONDITIONS

    EPA Science Inventory

    Small mammals locate buried wet seeds more efficiently than buried dry seeds. This may be attributable to emission of volatile compounds by the seeds. To test this hypothesis I measured emission of volatile compounds from seeds of three plant species (Pinus contorta, Purshia tr...

  19. [Infrared spectroscopic study on the component and vigor analysis of Cistanche deserticola seeds].

    PubMed

    Xu, Rong; Sun, Su-Qin; Chen, Jun; Chen, Shi-Lin; Zhou, Feng

    2009-01-01

    Comparative study of the different parts of cistanche deserticola seeds and their changes after different processing were examined by Fourier transform infrared spectroscopy spectra (FTIR). The results of the analysis showed that components in the cistanche deserticola seeds were abundant, which contained characteristic absorption peaks of protein, fat and carbohydrate. As well, pectin and aromatic compound can be also found in the seeds. However, the components were different in different parts of cistanche deserticola seeds. The characteristic absorption peak intensities of fat at 2,926, 1,746, 1,161 and 721 cm(-1) were the strongest in the seed kernels. However, the seed coats mainly consisted of carbohydrate and pectin, which were showed at 1,054 cm(-1). The contents of protein and carbohydrate were decreased distinctly in the moldy and dead seeds after processing. The characteristic absorption peak intensity ratio of protein to fat (I1,630/I1,745 ) was all higher than 1.05 in the live seeds. The characteristic absorption peak intensity ratio of amido link I of protein to fat (11,653/I1,745) in the dead seed kernels of the cistanche deserticola was decreased from 0.31 to 0. 23, which was 25.8% less than that in vital seed kernels. The results suggest that FTIR not only can be used in fast comprehensive analysis of seed components, but also can be used in the seed vigor analysis, seed longevity determination and seed quality evaluation.

  20. Brachytherapy in early prostate cancer--early experience.

    PubMed

    Jose, B O; Bailen, J L; Albrink, F H; Steinbock, G S; Cornett, M S; Benson, D C; Schmied, W K; Medley, R N; Spanos, W J; Paris, K J; Koerner, P D; Gatenby, R A; Wilson, D L; Meyer, R

    1999-01-01

    Use of brachytherapy with radioactive seeds in the management of early prostate cancer is commonly used in the United States. The early experience has been reported from the prostate treatment centers in Seattle for the last 10 years. In this manuscript we are reporting our early experience of 150 radioactive seed implantations in early stage prostate cancer using either Iodine 125 or Palladium 103 seeds. The average age of the patient is 66 years and the median Gleason score is 5.4 with a median PSA of 6. A brief description of the evolution of the treatment of prostate cancer as well as the preparation for the seed implantation using the volume study with ultrasound of the prostate, pubic arch study using CT scan of the pelvis and the complete planning using the treatment planning computers are discussed. We also have described the current technique which is used in our experience based on the Seattle guidelines. We plan a follow-up report with the results of the studies with longer follow-up.