Sample records for iaea trs-398 protocol

  1. Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international Codes of Practice

    NASA Astrophysics Data System (ADS)

    Andreo, Pedro; Saiful Huq, M.; Westermark, Mathias; Song, Haijun; Tilikidis, Aris; DeWerd, Larry; Shortt, Ken

    2002-09-01

    A new international Code of Practice for radiotherapy dosimetry co-sponsored by several international organizations has been published by the IAEA, TRS-398. It is based on standards of absorbed dose to water, whereas previous protocols (TRS-381 and TRS-277) were based on air kerma standards. To estimate the changes in beam calibration caused by the introduction of TRS-398, a detailed experimental comparison of the dose determination in reference conditions in high-energy photon and electron beams has been made using the different IAEA protocols. A summary of the formulation and reference conditions in the various Codes of Practice, as well as of their basic data, is presented first. Accurate measurements have been made in 25 photon and electron beams from 10 clinical accelerators using 12 different cylindrical and plane-parallel chambers, and dose ratios under different conditions of TRS-398 to the other protocols determined. A strict step-by-step checklist was followed by the two participating clinical institutions to ascertain that the resulting calculations agreed within tenths of a per cent. The maximum differences found between TRS-398 and the previous Codes of Practice TRS-277 (2nd edn) and TRS-381 are of the order of 1.5-2.0%. TRS-398 yields absorbed doses larger than the previous protocols, around 1.0% for photons (TRS-277) and for electrons (TRS-381 and TRS-277) when plane-parallel chambers are cross-calibrated. For the Markus chamber, results show a very large variation, although a fortuitous cancellation of the old stopping powers with the ND,w/NK ratios makes the overall discrepancy between TRS-398 and TRS-277 in this case smaller than for well-guarded plane-parallel chambers. Chambers of the Roos-type with a 60Co ND,w calibration yield the maximum discrepancy in absorbed dose, which varies between 1.0% and 1.5% for TRS-381 and between 1.5% and 2.0% for TRS-277. Photon beam calibrations using directly measured or calculated TPR20,10 from a percentage

  2. Comparison of AAPM Addendum to TG-51, IAEA TRS-398, and JSMP 12: Calibration of photon beams in water.

    PubMed

    Kinoshita, Naoki; Oguchi, Hiroshi; Nishimoto, Yasuhiro; Adachi, Toshiki; Shioura, Hiroki; Kimura, Hirohiko; Doi, Kunio

    2017-09-01

    The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recommendations given in AAPM TG-51 and the Addendum to TG-51, IAEA TRS-398, and JSMP 12. This study was performed using measurements with flattened photon beams with nominal energies of 6 and 10 MV. Three widely used ionization chambers with different compositions, Exradin A12, PTW 30013, and IBA FC65-P, were employed. Fully corrected charge readings obtained for the three chambers according to AAPM TG-51 and the Addendum to TG-51, which included the correction for the radiation beam profile (P rp ), showed variations of 0.2% and 0.3% at 6 and 10 MV, respectively, from the readings corresponding to IAEA TRS-398 and JSMP 12. The values for the beam quality conversion factor k Q obtained according to the three protocols agreed within 0.5%; the only exception was a 0.6% difference between the results obtained at 10 MV for Exradin A12 according to IAEA TRS-398 and AAPM TG-51 and the Addendum to TG-51. Consequently, the values for the absorbed dose to water obtained for the three protocols agreed within 0.4%; the only exception was a 0.6% difference between the values obtained at 10 MV for PTW 30013 according to AAPM TG-51 and the Addendum to TG-51, and JSMP 12. While the difference in the absorbed dose to water determined by the three protocols depends on the k Q and P rp values, the absorbed dose to water obtained according to the three protocols agrees within the relative uncertainties for the three protocols. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  3. Reference Dosimetry according to the New German Protocol DIN 6800-2 and Comparison with IAEA TRS 398 and AAPM TG 51*

    PubMed Central

    Zakaria, A; Schuette, W; Younan, C

    2011-01-01

    The preceding DIN 6800-2 (1997) protocol has been revised by a German task group and its latest version was published in March 2008 as the national standard dosimetry protocol DIN 6800-2 (2008 March). Since then, in Germany the determination of absorbed dose to water for high-energy photon and electron beams has to be performed according to this new German dosimetry protocol. The IAEA Code of Practice TRS 398 (2000) and the AAPM TG-51 are the two main protocols applied internationally. The new German version has widely adapted the methodology and dosimetric data of TRS-398. This paper investigates systematically the DIN 6800-2 protocol and compares it with the procedures and results obtained by using the international protocols. The investigation was performed with 6 MV and 18 MV photon beams as well as with electron beams from 5 MeV to 21 MeV. While only cylindrical chambers were used for photon beams, the measurements of electron beams were performed by using cylindrical and plane-parallel chambers. It was found that the discrepancies in the determination of absorbed dose to water among the three protocols were 0.23% for photon beams and 1.2% for electron beams. The determination of water absorbed dose was also checked by a national audit procedure using TLDs. The comparison between the measurements following the DIN 6800-2 protocol and the TLD audit-procedure confirmed a difference of less than 2%. The advantage of the new German protocol DIN 6800-2 lies in the renouncement on the cross calibration procedure as well as its clear presentation of formulas and parameters. In the past, the different protocols evoluted differently from time to time. Fortunately today, a good convergence has been obtained in concepts and methods. PMID:22287987

  4. Reference Dosimetry according to the New German Protocol DIN 6800-2 and Comparison with IAEA TRS 398 and AAPM TG 51.

    PubMed

    Zakaria, A; Schuette, W; Younan, C

    2011-04-01

    The preceding DIN 6800-2 (1997) protocol has been revised by a German task group and its latest version was published in March 2008 as the national standard dosimetry protocol DIN 6800-2 (2008 March). Since then, in Germany the determination of absorbed dose to water for high-energy photon and electron beams has to be performed according to this new German dosimetry protocol. The IAEA Code of Practice TRS 398 (2000) and the AAPM TG-51 are the two main protocols applied internationally. The new German version has widely adapted the methodology and dosimetric data of TRS-398. This paper investigates systematically the DIN 6800-2 protocol and compares it with the procedures and results obtained by using the international protocols. The investigation was performed with 6 MV and 18 MV photon beams as well as with electron beams from 5 MeV to 21 MeV. While only cylindrical chambers were used for photon beams, the measurements of electron beams were performed by using cylindrical and plane-parallel chambers. It was found that the discrepancies in the determination of absorbed dose to water among the three protocols were 0.23% for photon beams and 1.2% for electron beams. The determination of water absorbed dose was also checked by a national audit procedure using TLDs. The comparison between the measurements following the DIN 6800-2 protocol and the TLD audit-procedure confirmed a difference of less than 2%. The advantage of the new German protocol DIN 6800-2 lies in the renouncement on the cross calibration procedure as well as its clear presentation of formulas and parameters. In the past, the different protocols evoluted differently from time to time. Fortunately today, a good convergence has been obtained in concepts and methods.

  5. Comparison between the TRS-398 code of practice and the TG-51 dosimetry protocol for flattening filter free beams

    NASA Astrophysics Data System (ADS)

    Lye, J. E.; Butler, D. J.; Oliver, C. P.; Alves, A.; Lehmann, J.; Gibbons, F. P.; Williams, I. M.

    2016-07-01

    Dosimetry protocols for external beam radiotherapy currently in use, such as the IAEA TRS-398 and AAPM TG-51, were written for conventional linear accelerators. In these accelerators, a flattening filter is used to produce a beam which is uniform at water depths where the ionization chamber is used to measure the absorbed dose. Recently, clinical linacs have been implemented without the flattening filter, and published theoretical analysis suggested that with these beams a dosimetric error of order 0.6% could be expected for IAEA TRS-398, because the TPR20,10 beam quality index does not accurately predict the stopping power ratio (water to air) for the softer flattening-filter-free (FFF) beam spectra. We measured doses on eleven FFF linacs at 6 MV and 10 MV using both dosimetry protocols and found average differences of 0.2% or less. The expected shift due to stopping powers was not observed. We present Monte Carlo k Q calculations which show a much smaller difference between FFF and flattened beams than originally predicted. These results are explained by the inclusion of the added backscatter plates and build-up filters used in modern clinical FFF linacs, compared to a Monte Carlo model of an FFF linac in which the flattening filter is removed and no additional build-up or backscatter plate is added.

  6. Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams

    NASA Astrophysics Data System (ADS)

    Saiful Huq, M.; Andreo, Pedro; Song, Haijun

    2001-11-01

    The International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) have published new protocols for the calibration of radiotherapy beams. These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standards laboratory's reference quality beam. This paper compares the recommendations of the two protocols in two ways: (i) by analysing in detail the differences in the basic data included in the two protocols for photon and electron beam dosimetry and (ii) by performing measurements in clinical photon and electron beams and determining the absorbed dose to water following the recommendations of the two protocols. Measurements were made with two Farmer-type ionization chambers and three plane-parallel ionization chamber types in 6, 18 and 25 MV photon beams and 6, 8, 10, 12, 15 and 18 MeV electron beams. The Farmer-type chambers used were NE 2571 and PTW 30001, and the plane-parallel chambers were a Scanditronix-Wellhöfer NACP and Roos, and a PTW Markus chamber. For photon beams, the measured ratios TG-51/TRS-398 of absorbed dose to water Dw ranged between 0.997 and 1.001, with a mean value of 0.999. The ratios for the beam quality correction factors kQ were found to agree to within about +/-0.2% despite significant differences in the method of beam quality specification for photon beams and in the basic data entering into kQ. For electron beams, dose measurements were made using direct ND,w calibrations of cylindrical and plane-parallel chambers in a 60Co gamma-ray beam, as well as cross-calibrations of plane-parallel chambers in a high-energy electron beam. For the direct ND,w calibrations the ratios TG-51/TRS-398 of absorbed dose to water Dw were found to lie between 0.994 and 1.018 depending upon the chamber and electron beam energy used, with mean values of 0.996, 1.006, and 1.017, respectively, for the cylindrical, well-guarded and not well-guarded plane

  7. SU-E-T-204: Comparison of Absorbed-Dose to Water in High-Energy Photon Beams Based On Addendum AAPM TG-51, IAEA TRS-398, and JSMP 12

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinoshita, N; Kita, A; Yoshioka, C

    Purpose: Several clinical reference dosimetry protocols for absorbed-dose to water have recently been published: The American Association of Physicists in Medicine (AAPM) published an Addendum to the AAPM’s TG-51 (Addendum TG-51) in April 2014, and the Japan Society of Medical Physics (JSMP) published the Japan Society of Medical Physics 12 (JSMP12), a clinical reference dosimetry protocol, in September 2012. This investigation compared and evaluated the absorbed-dose to water of high-energy photon beams according to Addendum TG-51, International Atomic Energy Agency Technical Report Series No. 398 (TRS-398), and JSMP12. Methods: Differences in the respective beam quality conversion factors with Addendum TG-51,more » TRS-398, and JSMP12 were analyzed and the absorbed-dose to water using 6- and 10-MV photon beams was measured according to the protocols recommended in Addendum TG-51, TRS-398, and JSMP12. The measurements were conducted using two Farmer-type ionization chambers, Exradin A12 and PTW 30013. Results: The beam quality conversion factors for both the 6- and 10-MV photon beams with Addendum TG-51 were within 0.6%, in agreement with the beam quality conversion factors with TRS-398 and JSMP12. The Exradin A12 provided an absorbed-dose to water ratio from 1.003 to 1.006 with TRS-398 / Addendum TG-51 and from 1.004 to 1.005 with JSMP 12 / Addendum TG-51, whereas the PTW 30013 provided a ratio of 1.001 with TRS-398 / Addendum TG-51 and a range from 0.997 to 0.999 with JSMP 12 / Addendum TG-51. Conclusion: Despite differences in the beam quality conversion factor, no major differences were seen in the absorbed-dose to water with Addendum TG-51, TRS-398, and JSMP12. However, Addendum TG-51 provides the most recent data for beam quality conversion factors based on Monte Carlo simulation and greater detail for the measurement protocol. Therefore, the absorbed-dose to water measured with Addendum TG-51 is an estimate with less uncertainty.« less

  8. Absolute dose determination in high-energy electron beams: Comparison of IAEA dosimetry protocols

    PubMed Central

    Sathiyan, S.; Ravikumar, M.

    2008-01-01

    In this study, absorbed doses were measured and compared for high-energy electrons (6, 9, 12, 16, and 20 MeV) using International Atomic Energy Agency (IAEA), Technical Reports Series No. 277 (TRS), TRS 381, and TRS 398 dosimetry protocols. Absolute dose measurements were carried out using FC65-G Farmer chamber and Nordic Association of Clinical Physicists (NACP) parallel plate chamber with DOSE1 electrometer in WP1-D water phantom for reference field size of 15 × 15 cm2 at 100 cm source-to-surface distance. The results show that the difference between TRS 398 and TRS 381 was about 0.24% to 1.3% depending upon the energy, and the maximum difference between TRS 398 and TRS 277 was 1.5%. The use of cylindrical chamber in electron beam gives the maximum dose difference between the TRS 398 and TRS 277 in the order of 1.4% for energies above 10 MeV (R50 > 4 g/cm2). It was observed that the accuracy of dose estimation was better with the protocols based on the water calibration procedures, as no conversion quantities are involved for conversion of dose from air to water. The cross-calibration procedure of parallel plate chamber with high-energy electron beams is recommended as it avoids pwall correction factor entering into the determination of kQ,Qo. PMID:19893700

  9. A dosimetry study comparing NCS report-5, IAEA TRS-381, AAPM TG-51 and IAEA TRS-398 in three clinical electron beam energies

    NASA Astrophysics Data System (ADS)

    Palmans, Hugo; Nafaa, Laila; de Patoul, Nathalie; Denis, Jean-Marc; Tomsej, Milan; Vynckier, Stefaan

    2003-05-01

    New codes of practice for reference dosimetry in clinical high-energy photon and electron beams have been published recently, to replace the air kerma based codes of practice that have determined the dosimetry of these beams for the past twenty years. In the present work, we compared dosimetry based on the two most widespread absorbed dose based recommendations (AAPM TG-51 and IAEA TRS-398) with two air kerma based recommendations (NCS report-5 and IAEA TRS-381). Measurements were performed in three clinical electron beam energies using two NE2571-type cylindrical chambers, two Markus-type plane-parallel chambers and two NACP-02-type plane-parallel chambers. Dosimetry based on direct calibrations of all chambers in 60Co was investigated, as well as dosimetry based on cross-calibrations of plane-parallel chambers against a cylindrical chamber in a high-energy electron beam. Furthermore, 60Co perturbation factors for plane-parallel chambers were derived. It is shown that the use of 60Co calibration factors could result in deviations of more than 2% for plane-parallel chambers between the old and new codes of practice, whereas the use of cross-calibration factors, which is the first recommendation in the new codes, reduces the differences to less than 0.8% for all situations investigated here. The results thus show that neither the chamber-to-chamber variations, nor the obtained absolute dose values are significantly altered by changing from air kerma based dosimetry to absorbed dose based dosimetry when using calibration factors obtained from the Laboratory for Standard Dosimetry, Ghent, Belgium. The values of the 60Co perturbation factor for plane-parallel chambers (katt . km for the air kerma based and pwall for the absorbed dose based codes of practice) that are obtained from comparing the results based on 60Co calibrations and cross-calibrations are within the experimental uncertainties in agreement with the results from other investigators.

  10. Determination of absorbed dose to water for high-energy photon and electron beams-comparison of the standards DIN 6800-2 (1997), IAEA TRS 398 (2000) and DIN 6800-2 (2006).

    PubMed

    Zakaria, Golam Abu; Schuette, Wilhelm

    2007-01-01

    For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit.

  11. Determination of absorbed dose to water for high-energy photon and electron beams-comparison of the standards DIN 6800-2 (1997), IAEA TRS 398 (2000) and DIN 6800-2 (2006)

    PubMed Central

    Zakaria, Golam Abu; Schuette, Wilhelm

    2007-01-01

    For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit. PMID:21217912

  12. The calibration of a Scanditronix-Wellhöfer thimble chamber for photon dosimetry using the IAEA TRS 277 code of practice.

    PubMed

    Fourie, O L

    2004-03-01

    This note investigates the calibration of a Scanditronix-Wellhöfer type FC65-G ionisation chamber to be used in clinical photon dosimetry. The current Adaptation by the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) of the IAEA TRS 277 dosimetry protocol makes no provision for this type of chamber. The absorbed dose to air calibration coefficient ND was therefore calculated from the air kerma calibration coefficient NK using the formalism of the IAEA TRS 277 protocol and it is shown that the value of the correction factor kmkatt for the FC65-G chamber is identical to that of the NE 2571 chamber. ND was also determined experimentally from a cross calibration against an NE 2571 dosimetry. It was found that there is a good correspondence between the calculated and measured values. To establish to what extent the ACPSEM Adaptation can be used for the FC65-G chamber, values for the ratio of stopping powers in water and air (Sw,air)Q and the perturbation correction factor pQ were calculated using the TRS 277 protocol. From these results it is shown that over the range of beam qualities TPR20,10 = 0.59 to TPR20,10 = 0.78 the Adaptation can be used for the FC65-G chamber.

  13. Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.

    PubMed Central

    Henríquez, Francisco Cutanda

    2009-01-01

    Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS‐398 and AAPM TG‐51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison has been carried out for photon beams of nominal energies: 4 MV, 6 MV, 8 MV, 10 MV and 18 MV. An NE 2571 graphite ionization chamber was used in this study, cross‐calibrated against an NE 2611A Secondary Standard, calibrated in the National Physical Laboratory (NPL). Absolute dose in reference conditions was obtained using each of these three protocols including: beam quality indices, beam quality conversion factors both theoretical and NPL experimental ones, correction factors for influence quantities and absolute dose measurements. Each protocol recommendations have been strictly followed. Uncertainties have been obtained according to the ISO Guide to the Expression of Uncertainty in Measurement. Absorbed dose obtained according to all three protocols agree within experimental uncertainty. The largest difference between absolute dose results for two protocols is obtained for the highest energy: 0.7% between IPSM 1990 and IAEA TRS‐398 using theoretical beam quality conversion factors. PACS number: 87.55.tm

  14. The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams.

    PubMed

    Yoshiyama, Fumiaki; Araki, Fujio; Ono, Takeshi

    2010-07-01

    In this study, we calculated perturbation correction factors for cylindrical ionization chambers in high-energy photon beams by using Monte Carlo simulations. We modeled four Farmer-type cylindrical chambers with the EGSnrc/Cavity code and calculated the cavity or electron fluence correction factor, P (cav), the displacement correction factor, P (dis), the wall correction factor, P (wall), the stem correction factor, P (stem), the central electrode correction factor, P (cel), and the overall perturbation correction factor, P (Q). The calculated P (dis) values for PTW30010/30013 chambers were 0.9967 +/- 0.0017, 0.9983 +/- 0.0019, and 0.9980 +/- 0.0019, respectively, for (60)Co, 4 MV, and 10 MV photon beams. The value for a (60)Co beam was about 1.0% higher than the 0.988 value recommended by the IAEA TRS-398 protocol. The P (dis) values had a substantial discrepancy compared to those of IAEA TRS-398 and AAPM TG-51 at all photon energies. The P (wall) values were from 0.9994 +/- 0.0020 to 1.0031 +/- 0.0020 for PTW30010 and from 0.9961 +/- 0.0018 to 0.9991 +/- 0.0017 for PTW30011/30012, in the range of (60)Co-10 MV. The P (wall) values for PTW30011/30012 were around 0.3% lower than those of the IAEA TRS-398. Also, the chamber response with and without a 1 mm PMMA water-proofing sleeve agreed within their combined uncertainty. The calculated P (stem) values ranged from 0.9945 +/- 0.0014 to 0.9965 +/- 0.0014, but they are not considered in current dosimetry protocols. The values were no significant difference on beam qualities. P (cel) for a 1 mm aluminum electrode agreed within 0.3% with that of IAEA TRS-398. The overall perturbation factors agreed within 0.4% with those for IAEA TRS-398.

  15. Radionuclide transfer to fruit in the IAEA TRS No. 472

    NASA Astrophysics Data System (ADS)

    Carini, F.; Pellizzoni, M.; Giosuè, S.

    2012-04-01

    This paper describes the approach taken to present the information on fruits in the IAEA report TRS No. 472, supported by the IAEA-TECDOC-1616, which describes the key transfer processes, concepts and conceptual models regarded as important for dose assessment, as well as relevant parameters for modelling radionuclide transfer in fruits. Information relate to fruit plants grown in agricultural ecosystems of temperate regions. The relative significance of each pathway after release of radionuclides depends upon the radionuclide, the kind of crop, the stage of plant development and the season at time of deposition. Fruit intended as a component of the human diet is borne by plants that are heterogeneous in habits, and morphological and physiological traits. Information on radionuclides in fruit systems has therefore been rationalised by characterising plants in three groups: woody trees, shrubs, and herbaceous plants. Parameter values have been collected from open literature, conference proceedings, institutional reports, books and international databases. Data on root uptake are reported as transfer factor values related to fresh weight, being consumption data for fruits usually given in fresh weight.

  16. Beam quality corrections for parallel-plate ion chambers in electron reference dosimetry

    NASA Astrophysics Data System (ADS)

    Zink, K.; Wulff, J.

    2012-04-01

    Current dosimetry protocols (AAPM, IAEA, IPEM, DIN) recommend parallel-plate ionization chambers for dose measurements in clinical electron beams. This study presents detailed Monte Carlo simulations of beam quality correction factors for four different types of parallel-plate chambers: NACP-02, Markus, Advanced Markus and Roos. These chambers differ in constructive details which should have notable impact on the resulting perturbation corrections, hence on the beam quality corrections. The results reveal deviations to the recommended beam quality corrections given in the IAEA TRS-398 protocol in the range of 0%-2% depending on energy and chamber type. For well-guarded chambers, these deviations could be traced back to a non-unity and energy-dependent wall perturbation correction. In the case of the guardless Markus chamber, a nearly energy-independent beam quality correction is resulting as the effects of wall and cavity perturbation compensate each other. For this chamber, the deviations to the recommended values are the largest and may exceed 2%. From calculations of type-B uncertainties including effects due to uncertainties of the underlying cross-sectional data as well as uncertainties due to the chamber material composition and chamber geometry, the overall uncertainty of calculated beam quality correction factors was estimated to be <0.7%. Due to different chamber positioning recommendations given in the national and international dosimetry protocols, an additional uncertainty in the range of 0.2%-0.6% is present. According to the IAEA TRS-398 protocol, the uncertainty in clinical electron dosimetry using parallel-plate ion chambers is 1.7%. This study may help to reduce this uncertainty significantly.

  17. Experimental validation of beam quality correction factors for proton beams

    NASA Astrophysics Data System (ADS)

    Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor

    2015-04-01

    This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.

  18. 47 CFR 64.606 - Internet-based TRS provider and TRS program certification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false Internet-based TRS provider and TRS program... Services and Related Customer Premises Equipment for Persons With Disabilities § 64.606 Internet-based TRS... including notification in the Federal Register. (2) Internet-based TRS provider. Any entity desiring to...

  19. 47 CFR 64.606 - Internet-based TRS provider and TRS program certification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Internet-based TRS provider and TRS program... Services and Related Customer Premises Equipment for Persons With Disabilities § 64.606 Internet-based TRS... including notification in the Federal Register. (2) Internet-based TRS provider. Any entity desiring to...

  20. 47 CFR 64.606 - Internet-based TRS provider and TRS program certification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Internet-based TRS provider and TRS program... Services and Related Customer Premises Equipment for Persons With Disabilities § 64.606 Internet-based TRS... including notification in the Federal Register. (2) Internet-based TRS provider. Any entity desiring to...

  1. [Determination of absorbed dose to water for high energy photon and electron beams--comparison of different dosimetry protocols].

    PubMed

    Zakaria, Golam Abu; Schütte, Wilhelm

    2003-01-01

    The determination of absorbed dose to water for high-energy photon and electron beams is performed in Germany according to the dosimetry protocol DIN 6800-2 (1997). At an international level, the main protocols used are the AAPM dosimetry protocol TG-51 (1999) and the IAEA Code of Practice TRS-398 (2000). The present paper systematically compares these three dosimetry protocols, and identifies similarities and differences. The investigations were performed using 4 and 10 MV photon beams, as well as 6, 8, 9, 10, 12 and 14 MeV electron beams. Two cylindrical and two plane-parallel type chambers were used for measurements. In general, the discrepancies among the three protocols were 1.0% for photon beams and 1.6% for electron beams. Comparative measurements in the context of measurement technical control (MTK) with TLD showed a deviation of less than 1.3% between the measurements obtained according to protocols DIN 6800-2 and MTK (exceptions: 4 MV photons with 2.9% and 6 MeV electrons with 2.4%). While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using both cylindrical and plane-parallel chambers (the latter used after a cross-calibration to a cylindrical chamber, as required by the respective dosimetry protocols). Notably, unlike recommended in the corresponding protocols, we found out that cylindrical chambers can be used also for energies from 6 to 10 MeV.

  2. Absorbed dose to water based dosimetry versus air kerma based dosimetry for high-energy photon beams: an experimental study.

    PubMed

    Palmans, Hugo; Nafaa, Laila; De, Jans Jo; Gillis, Sofie; Hoornaert, Marie-Thérèse; Martens, Chantal; Piessens, Marleen; Thierens, Hubert; Van der Plaetsen, Ann; Vynckier, Stefaan

    2002-02-07

    In recent years, a change has been proposed from air kerma based reference dosimetry to absorbed dose based reference dosimetry for all radiotherapy beams of ionizing radiation. In this paper, a dosimetry study is presented in which absorbed dose based dosimetry using recently developed formalisms was compared with air kerma based dosimetry using older formalisms. Three ionization chambers of each of three different types were calibrated in terms of absorbed dose to water and air kerma and sent to five hospitals. There, reference dosimetry with all the chambers was performed in a total of eight high-energy clinical photon beams. The selected chamber types were the NE2571, the PTW-30004 and the Wellhöfer-FC65G (previously Wellhöfer-IC70). Having a graphite wall, they exhibit a stable volume and the presence of an aluminium electrode ensures the robustness of these chambers. The data were analysed with the most important recommendations for clinical dosimetry: IAEA TRS-398, AAPM TG-51, IAEA TRS-277, NCS report-2 (presently recommended in Belgium) and AAPM TG-21. The necessary conversion factors were taken from those protocols, or calculated using the data in the different protocols if data for a chamber type are lacking. Polarity corrections were within 0.1% for all chambers in all beams. Recombination corrections were consistent with theoretical predictions, did not vary within a chamber type and only slightly between different chamber types. The maximum chamber-to-chamber variations of the dose obtained with the different formalisms within the same chamber type were between 0.2% and 0.6% for the NE2571, between 0.2% and 0.6% for the PTW-30004 and 0.1% and 0.3% for the Wellhöfer-FC65G for the different beams. The absorbed dose results for the NE2571 and Wellhöfer-FC65G chambers were in good agreement for all beams and all formalisms. The PTW-30004 chambers gave a small but systematically higher result compared to the result for the NE2571 chambers (on the

  3. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com; Vijande, J.; García-Martínez, T.

    2015-08-15

    Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate ofmore » the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW

  4. TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seuntjens, J.

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  5. 47 CFR 64.611 - Internet-based TRS registration.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Internet-based TRS Numbering Directory any toll free number that has not been transferred to a subscription... 47 Telecommunication 3 2014-10-01 2014-10-01 false Internet-based TRS registration. 64.611 Section... Customer Premises Equipment for Persons With Disabilities § 64.611 Internet-based TRS registration. (a...

  6. 47 CFR 64.611 - Internet-based TRS registration.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... number assigned or issued to any Registered Internet-based TRS User. (e) Toll free numbers. A VRS or IP... effective date of this Order remove from the Internet-based TRS Numbering Directory any toll free number... 47 Telecommunication 3 2012-10-01 2012-10-01 false Internet-based TRS registration. 64.611 Section...

  7. 47 CFR 64.613 - Numbering directory for internet-based TRS users.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Numbering directory for internet-based TRS... for internet-based TRS users. (a) TRS Numbering Directory. (1) The TRS Numbering Directory shall contain records mapping the NANP telephone number of each Registered Internet-based TRS User to a unique...

  8. 47 CFR 64.613 - Numbering directory for Internet-based TRS users.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Numbering directory for Internet-based TRS... for Internet-based TRS users. (a) TRS Numbering Directory. (1) The TRS Numbering Directory shall contain records mapping the geographically appropriate NANP telephone number of each Registered Internet...

  9. 47 CFR 64.613 - Numbering directory for Internet-based TRS users.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Numbering directory for Internet-based TRS... for Internet-based TRS users. (a) TRS Numbering Directory. (1) The TRS Numbering Directory shall contain records mapping the geographically appropriate NANP telephone number of each Registered Internet...

  10. 47 CFR 64.613 - Numbering directory for Internet-based TRS users.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false Numbering directory for Internet-based TRS... for Internet-based TRS users. (a) TRS Numbering Directory. (1) The TRS Numbering Directory shall contain records mapping the geographically appropriate NANP telephone number of each Registered Internet...

  11. 47 CFR 64.606 - Internet-based TRS provider and TRS program certification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of Internet-based TRS to be provided (i.e., VRS, IP Relay, and/or IP captioned telephone relay... IP Relay providers certified under this section must notify the Commission of substantive changes in...

  12. TRS-80 at the Maine State Library.

    ERIC Educational Resources Information Center

    Wismer, Donald

    This report describes the applications and work flow of a TRS-80 microcomputer at the Maine State Library, and provides sample computer-generated records and programs used with the TRS-80. The machine was chosen for its price, availability, and compatibility with machines already in Maine's schools. It is used for mailing list management (with…

  13. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    NASA Astrophysics Data System (ADS)

    Lucero, J. F.; Rojas, J. I.

    2016-07-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient's entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  14. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt; Hope International, Guatemala; Rojas, J. I., E-mail: isaac.rojas@siglo21.cr

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  15. 47 CFR 64.615 - TRS User Registration Database and administrator.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false TRS User Registration Database and... Registration Database and administrator. (a) TRS User Registration Database. (1) VRS providers shall validate... Database on a per-call basis. Emergency 911 calls are excepted from this requirement. (i) Validation shall...

  16. 47 CFR 64.615 - TRS User Registration Database and administrator.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false TRS User Registration Database and... Registration Database and administrator. (a) TRS User Registration Database. (1) VRS providers shall validate... Database on a per-call basis. Emergency 911 calls are excepted from this requirement. (i) Validation shall...

  17. Relativity and the TRS-80.

    ERIC Educational Resources Information Center

    Levin, Sidney

    1984-01-01

    Presents the listing (TRS-80) for a computer program which derives the relativistic equation (employing as a model the concept of a moving clock which emits photons at regular intervals) and calculates transformations of time, mass, and length with increasing velocities (Einstein-Lorentz transformations). (JN)

  18. 40 CFR 60.283 - Standard for total reduced sulfur (TRS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for total reduced sulfur (TRS). 60.283 Section 60.283 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Pulp Mills § 60.283 Standard for total reduced sulfur (TRS). (a) On and after the date on which the...

  19. 40 CFR 60.283 - Standard for total reduced sulfur (TRS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for total reduced sulfur (TRS). 60.283 Section 60.283 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Pulp Mills § 60.283 Standard for total reduced sulfur (TRS). (a) On and after the date on which the...

  20. 40 CFR 60.283 - Standard for total reduced sulfur (TRS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standard for total reduced sulfur (TRS). 60.283 Section 60.283 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Pulp Mills § 60.283 Standard for total reduced sulfur (TRS). (a) On and after the date on which the...

  1. 40 CFR 60.283 - Standard for total reduced sulfur (TRS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standard for total reduced sulfur (TRS). 60.283 Section 60.283 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Pulp Mills § 60.283 Standard for total reduced sulfur (TRS). (a) On and after the date on which the...

  2. 47 CFR 64.6040 - Rates for Telecommunications Relay Service (TRS) calling.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 3 2014-10-01 2014-10-01 false Rates for Telecommunications Relay Service (TRS) calling. 64.6040 Section 64.6040 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON....6040 Rates for Telecommunications Relay Service (TRS) calling. No Provider shall levy or collect any...

  3. Calibration of helical tomotherapy machine using EPR/alanine dosimetry.

    PubMed

    Perichon, Nicolas; Garcia, Tristan; François, Pascal; Lourenço, Valérie; Lesven, Caroline; Bordy, Jean-Marc

    2011-03-01

    Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10 x 10 cm2 square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40 x 5 cm2 defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) 60Co-gamma-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference 60Co-gamma-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then

  4. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.

    PubMed

    Hourdakis, Constantine J; Boziari, A

    2008-04-01

    Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002--2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside +/-3% and 31% outside +/-5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and discussed in details. This quality audit proved to be a

  5. 40 CFR 60.283a - Standard for total reduced sulfur (TRS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standard for total reduced sulfur (TRS). 60.283a Section 60.283a Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... 23, 2013 § 60.283a Standard for total reduced sulfur (TRS). (a) On and after the date on which the...

  6. A test of the IAEA code of practice for absorbed dose determination in photon and electron beams

    NASA Astrophysics Data System (ADS)

    Leitner, Arnold; Tiefenboeck, Wilhelm; Witzani, Josef; Strachotinsky, Christian

    1990-12-01

    The IAEA (International Atomic Energy Agency) code of practice TRS 277 gives recommendations for absorbed dose determination in high energy photon and electron beams based on the use of ionization chambers calibrated in terms of exposure of air kerma. The scope of the work was to test the code for cobalt 60 gamma radiation and for several radiation qualities at four different types of electron accelerators and to compare the ionization chamber dosimetry with ferrous sulphate dosimetry. The results show agreement between the two methods within about one per cent for all the investigated qualities. In addition the response of the TLD capsules of the IAEA/WHO TL dosimetry service was determined.

  7. SPECTRAL CORRECTION FACTORS FOR CONVENTIONAL NEUTRON DOSE METERS USED IN HIGH-ENERGY NEUTRON ENVIRONMENTS-IMPROVED AND EXTENDED RESULTS BASED ON A COMPLETE SURVEY OF ALL NEUTRON SPECTRA IN IAEA-TRS-403.

    PubMed

    Oparaji, U; Tsai, Y H; Liu, Y C; Lee, K W; Patelli, E; Sheu, R J

    2017-06-01

    This paper presents improved and extended results of our previous study on corrections for conventional neutron dose meters used in environments with high-energy neutrons (En > 10 MeV). Conventional moderated-type neutron dose meters tend to underestimate the dose contribution of high-energy neutrons because of the opposite trends of dose conversion coefficients and detection efficiencies as the neutron energy increases. A practical correction scheme was proposed based on analysis of hundreds of neutron spectra in the IAEA-TRS-403 report. By comparing 252Cf-calibrated dose responses with reference values derived from fluence-to-dose conversion coefficients, this study provides recommendations for neutron field characterization and the corresponding dose correction factors. Further sensitivity studies confirm the appropriateness of the proposed scheme and indicate that (1) the spectral correction factors are nearly independent of the selection of three commonly used calibration sources: 252Cf, 241Am-Be and 239Pu-Be; (2) the derived correction factors for Bonner spheres of various sizes (6"-9") are similar in trend and (3) practical high-energy neutron indexes based on measurements can be established to facilitate the application of these correction factors in workplaces. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. 27 CFR 19.398 - Alcohol.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Alcohol. 19.398 Section 19.398 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE... Articles Bottling, Packaging, and Removal of Products § 19.398 Alcohol. (a) Containers. Subject to the...

  9. Determination of the Sensibility Factors for TLD-100 Powder on the Energy of X-Ray of 50, 250 kVp; 192Ir, 137Cs and 60Co

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loaiza, Sandra P.; Alvarez, Jose T.

    2006-09-08

    TLD-100 powder is calibrated in terms of absorbed dose to water Dw, using the protocols AAPM TG61, AAPM TG43 and IAEA-TRS 398, for the energy of RX 50, 250 kVp, 137Cs and 60Co respectively. The calibration curves, TLD Response R versus Dw, are fitted by weighted least square by a quadratic polynomials; which are validated with the lack of fit and the Anderson-Darling normality test. The slope of these curves corresponds to the sensibility factor: Fs R/DW, [Fs] = nC Gy-1. The expanded uncertainties U's for these factors are obtained from the ANOVA tables. Later, the Fs' values are interpolatedmore » using the effective energy hvefec for the 192Ir. The SSDL sent a set of capsules with powder TLD-100 for two Hospitals. These irradiated them a nominal dose of Dw = 2 Gy. The results determined at SSDL are: for the Hospital A the Dw is overestimated in order to 4.8% and the Hospital B underestimates it in the range from -1.4% to -17.5%.« less

  10. CPP-TRS(C): On using visual cognitive symbols to enhance communication effectiveness

    NASA Technical Reports Server (NTRS)

    Tonfoni, Graziella

    1994-01-01

    Communicative Positioning Program/Text Representation Systems (CPP-TRS) is a visual language based on a system of 12 canvasses, 10 signals and 14 symbols. CPP-TRS is based on the fact that every communication action is the result of a set of cognitive processes and the whole system is based on the concept that you can enhance communication by visually perceiving text. With a simple syntax, CPP-TRS is capable of representing meaning and intention as well as communication functions visually. Those are precisely invisible aspects of natural language that are most relevant to getting the global meaning of a text. CPP-TRS reinforces natural language in human machine interaction systems. It complements natural language by adding certain important elements that are not represented by natural language by itself. These include communication intention and function of the text expressed by the sender, as well as the role the reader is supposed to play. The communication intention and function of a text and the reader's role are invisible in natural language because neither specific words nor punctuation conveys them sufficiently and unambiguously; they are therefore non-transparent.

  11. 14 CFR 398.11 - Funding reductions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Funding reductions. 398.11 Section 398.11 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.11 Funding...

  12. 14 CFR 398.11 - Funding reductions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Funding reductions. 398.11 Section 398.11 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.11 Funding...

  13. 14 CFR 398.11 - Funding reductions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Funding reductions. 398.11 Section 398.11 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) POLICY STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.11 Funding...

  14. 14 CFR 398.3 - Specific airports.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Specific airports. 398.3 Section 398.3... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.3 Specific airports. (a) At an eligible place, essential air service may be specified as service to a particular airport...

  15. 14 CFR 398.3 - Specific airports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Specific airports. 398.3 Section 398.3... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.3 Specific airports. (a) At an eligible place, essential air service may be specified as service to a particular airport...

  16. 14 CFR 398.3 - Specific airports.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Specific airports. 398.3 Section 398.3... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.3 Specific airports. (a) At an eligible place, essential air service may be specified as service to a particular airport...

  17. 14 CFR 398.3 - Specific airports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Specific airports. 398.3 Section 398.3... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.3 Specific airports. (a) At an eligible place, essential air service may be specified as service to a particular airport...

  18. 14 CFR 398.3 - Specific airports.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Specific airports. 398.3 Section 398.3... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.3 Specific airports. (a) At an eligible place, essential air service may be specified as service to a particular airport...

  19. Human cytomegalovirus TRS1 protein associates with the 7-methylguanosine mRNA cap and facilitates translation.

    PubMed

    Ziehr, Benjamin; Lenarcic, Erik; Vincent, Heather A; Cecil, Chad; Garcia, Benjamin; Shenk, Thomas; Moorman, Nathaniel J

    2015-06-01

    Viruses rely on the host translation machinery for the synthesis of viral proteins. Human cells have evolved sensors that recognize viral RNAs and inhibit mRNA translation in order to limit virus replication. Understanding how viruses manipulate the host translation machinery to gain access to ribosomes and disable the antiviral response is therefore a critical aspect of the host/pathogen interface. In this study, we used a proteomics approach to identify human cytomegalovirus (HCMV) proteins that might contribute to viral mRNA translation. The HCMV TRS1 protein (pTRS1) associated with the 7-methylguanosine mRNA cap, increased the total level of protein synthesis, and colocalized with mRNAs undergoing translation initiation during infection. pTRS1 stimulated translation of a nonviral reporter gene and increased the translation of a reporter containing an HCMV 5' untranslated region (5'UTR) to a greater extent. The preferential effect of pTRS1 on translation of an mRNA containing a viral 5'UTR required the pTRS1 RNA and double-stranded RNA-dependent protein kinase (PKR)-binding domains, and was likely the result of PKR inhibition. However, pTRS1 also stimulated the total level of protein synthesis and translation directed by an HCMV 5'UTR in cells lacking PKR. Thus our results demonstrate that pTRS1 stimulates translation through both PKR-dependent and PKR-independent mechanisms. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Human cytomegalovirus TRS1 protein associates with the 7-methylguanosine mRNA cap and facilitates translation

    PubMed Central

    Ziehr, Benjamin; Lenarcic, Erik; Vincent, Heather A.; Cecil, Chad; Garcia, Benjamin; Shenk, Thomas; Moorman, Nathaniel J.

    2015-01-01

    Viruses rely on the host translation machinery for the synthesis of viral proteins. Human cells have evolved sensors that recognize viral RNAs and inhibit mRNA translation in order to limit virus replication. Understanding how viruses manipulate the host translation machinery to gain access to ribosomes and disable the antiviral response is therefore a critical aspect of the host:pathogen interface. In this study we used a proteomics approach to identify human cytomegalovirus (HCMV) proteins that might contribute to viral mRNA translation. The HCMV TRS1 protein (pTRS1) associated with the 7-methylguanosine (m7G) mRNA cap, increased the total level of protein synthesis, and co-localized with mRNAs undergoing translation initiation during infection. pTRS1 stimulated translation of a non-viral reporter gene and increased the translation of a reporter containing an HCMV 5’ untranslated region (5’UTR) to a greater extent. The preferential effect of pTRS1 on translation of an mRNA containing a viral 5’UTR required the pTRS1 RNA and PKR binding domains, and was likely the result of PKR inhibition. However pTRS1 also stimulated the total level of protein synthesis and translation directed by an HCMV 5’UTR in cells lacking PKR. Thus our results demonstrate that pTRS1 stimulates translation through both PKR-dependent and PKR-independent mechanisms. PMID:25894605

  1. 14 CFR 398.11 - Funding reductions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Funding reductions. 398.11 Section 398.11... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.11 Funding... the annual subsidy in effect as of July 1 of the prior fiscal year by the total origin-and-destination...

  2. 14 CFR 398.11 - Funding reductions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Funding reductions. 398.11 Section 398.11... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.11 Funding... the annual subsidy in effect as of July 1 of the prior fiscal year by the total origin-and-destination...

  3. Department of Energy Efforts to Promote Universal Adherence to the IAEA Additional Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killinger, Mark H.; Hansen, Linda H.; Kovacic, Don N.

    2009-10-06

    Entry-into-force of the U.S. Additional Protocol (AP) in January 2009 continues to demonstrate the ongoing commitment by the United States to promote universal adherence to the AP. The AP is a critical tool for improving the International Atomic Energy Agency’s (IAEA) capabilities to detect undeclared activities that indicate a clandestine nuclear weapons program. This is because States Parties are required to provide information about, and access to, nuclear fuel cycle activities beyond their traditional safeguards reporting requirements. As part of the U.S. AP Implementation Act and Senate Resolution of Ratification, the Administration is required to report annually to Congress onmore » measures taken to achieve the adoption of the AP in non-nuclear weapon states, as well as assistance to the IAEA to promote the effective implementation of APs in those states. A key U.S. effort in this area is being managed by the International Nuclear Safeguards and Engagement Program (INSEP) of the U.S. Department of Energy (DOE). Through new and existing bilateral cooperation agreements, INSEP has initiated technical assistance projects for AP implementation with selected non-weapon states. States with which INSEP is currently cooperating include Vietnam and Thailand, with Indonesia, Algeria, Morocco, and other countries as possible future collaborators in the area of AP implementation. The INSEP collaborative model begins with a joint assessment with our partners to identify specific needs they may have regarding entering the AP into force and any impediments to successful implementation. An action plan is then developed detailing and prioritizing the necessary joint activities. Such assistance may include: advice on developing legal frameworks and regulatory documents; workshops to promote understanding of AP requirements; training to determine possible declarable activities; assistance in developing a system to collect and submit declarations; performing industry

  4. SU-E-T-408: Determination of KQ,Q0-Factors From Water and Graphite Calorimetry in a 60 MeV Proton Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossomme, S; Renaud, J; Sarfehnia, A

    2014-06-01

    Purpose: To reduce the uncertainty of the beam quality correction factor k Q,Q0, for scattered proton beams (SPB). This factor is used in dosimetry protocols, to determine absorbed dose-to-water with ionization chambers. For the Roos plane parallel chambers (RPPICs), the IAEA TRS-398 protocol estimates k Q,Q0-factor to be 1.004(for a beam quality Rres=2 g.cm{sup 2}), with an uncertainty of 2.1%. Methods: A graphite calorimeter (GCal), a water calorimeter (WCal) and RPPICs were exposed, in a single experiment, to a 60 MeV non-modulated SPB. RPPICs were calibrated in terms of absorbed dose-to-water in a 20 MeV electron beam. The calibration coefficientmore » is traceable to NPL's absorbed dose standards. Chamber measurements were corrected for environmental conditions, recombination and polarity. The WCal corrections include heat loss, heat defect and vessel perturbation. The GCal corrections include heat loss and absorbed dose conversion. Except for heat loss correction and its uncertainty in the WCal system, all major corrections were included in the analysis. Other minor corrections, such as beam profile non-uniformity, are still to be evaluated. Experimental k Q,Q0-factors were derived by comparing the results obtained with both calorimeters and ionometry. Results: The absorbed dose-to-water from both calorimeters was found to be within 1.3% with an uncertainty of 1.2%. k Q,Q0-factor for a RPPIC was found to be 0.998 and 1.011, with a standard uncertainty of 1.4% and 0.9% when the dose is based on the GCal and the WCal, respectively. Conclusion: Results suggest the possibility to determine k Q,Q0-values for PPICs in SPB with a lower uncertainty than specified in the TRS-398 thereby helping to reduce uncertainty on absorbed dose-to-water. The agreement between calorimeters confirms the possibility to use GCal or WCal as primary standard in SPB. Because of the dose conversion, the use of GCal may lead to slightly higher uncertainty, but is, at present

  5. 14 CFR 398.7 - Timing of flights.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Timing of flights. 398.7 Section 398.7... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.7 Timing of flights. To qualify as essential air service, flights must depart at reasonable times, considering the needs...

  6. 14 CFR 398.7 - Timing of flights.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Timing of flights. 398.7 Section 398.7... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.7 Timing of flights. To qualify as essential air service, flights must depart at reasonable times, considering the needs...

  7. 14 CFR 398.9 - Load factor standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Load factor standards. 398.9 Section 398.9... STATEMENTS GUIDELINES FOR INDIVIDUAL DETERMINATIONS OF BASIC ESSENTIAL AIR SERVICE § 398.9 Load factor standards. The load factor standards used in this part may be raised for individual eligible places under...

  8. 49 CFR 398.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Definitions. 398.1 Section 398.1 Transportation....1 Definitions. (a) Migrant worker. “Migrant worker” means any individual proceeding to or returning... amended (29 U.S.C. 203(f)) or section 3121(g) of the Internal Revenue Code of 1954 (26 U.S.C. 3121(g)). (b...

  9. 78 FR 49693 - Speech-to-Speech and Internet Protocol (IP) Speech-to-Speech Telecommunications Relay Services...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-15

    ...] Speech-to-Speech and Internet Protocol (IP) Speech-to-Speech Telecommunications Relay Services...: This is a summary of the Commission's Speech-to-Speech and Internet Protocol (IP) Speech-to-Speech...), Internet Protocol Relay (IP Relay), and IP captioned telephone service (IP CTS) as compensable forms of TRS...

  10. Ambient TRS Study, Phase I, Pine Hill, Alabama, February 2001

    EPA Pesticide Factsheets

    Study that shows the findings of the first phase of an investigation to identify sources of TRS emission that have a ground level impact on the Weyerhaeuser's Pine Hill, Alabama pulp and paper complex.

  11. Ambient TRS Study, Phase II, Pine Hill, Alabama, April 2002

    EPA Pesticide Factsheets

    Study that shows the findings of the first phase of an investigation to identify sources of TRS emission that have a ground level impact on the Weyerhaeuser's Pine Hill, Alabama pulp and paper complex.

  12. REVIEW OF THE NEGOTIATION OF THE MODEL PROTOCOL ADDITIONAL TO THE AGREEMENT(S) BETWEEN STATE(S) AND THE INTERNATIONAL ATOMIC ENERGY AGENCY FOR THE APPLICATION OF SAFEGUARDS, INFCIRC/540 (Corrected) VOLUME II/III IAEA COMMITTEE 24, Major Issues Underlying the Model Additional Protocol (1996-1997).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, M.D.; Saum-Manning, L.; Houck, F.

    Volume I of this Review traces the origins of the Model Additional Protocol. It covers the period from 1991, when events in Iraq triggered an intensive review of the safeguards system, until 1996, when the IAEA Board of Governors established Committee 24 to negotiate a new protocol to safeguards agreement. The period from 1991-1996 set the stage for this negotiation and shaped its outcome in important ways. During this 5-year period, many proposals for strengthening safeguards were suggested and reviewed. Some proposals were dropped, for example, the suggestion by the IAEA Secretariat to verify certain imports, and others were refined.more » A rough consensus was established about the directions in which the international community wanted to go, and this was reflected in the draft of an additional protocol that was submitted to the IAEA Board of Governors on May 6, 1996 in document GOV/2863, Strengthening the Effectiveness and Improving the Efficiency of the Safeguards System - Proposals For Implementation Under Complementary Legal Authority, A Report by the Director General. This document ended with a recommendation that, 'the Board, through an appropriate mechanism, finalize the required legal instrument taking as a basis the draft protocol proposed by the Secretariat and the explanation of the measures contained in this document.'« less

  13. 50 CFR 665.398 - Management area.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false Management area. 665.398 Section 665.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Management area. The Mariana fishery management area is the EEZ seaward of Guam and CNMI with the inner...

  14. 50 CFR 665.398 - Management area.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 13 2014-10-01 2014-10-01 false Management area. 665.398 Section 665.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Management area. The Mariana fishery management area is the EEZ seaward of Guam and CNMI with the inner...

  15. 50 CFR 665.398 - Management area.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 13 2013-10-01 2013-10-01 false Management area. 665.398 Section 665.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Management area. The Mariana fishery management area is the EEZ seaward of Guam and CNMI with the inner...

  16. 50 CFR 665.398 - Management area.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Management area. 665.398 Section 665.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Management area. The Mariana fishery management area is the EEZ seaward of Guam and CNMI with the inner...

  17. 50 CFR 665.398 - Management area.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Management area. 665.398 Section 665.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Management area. The Mariana fishery management area is the EEZ seaward of Guam and CNMI with the inner...

  18. Software Descriptions. Micro-computers: Atari, Apple, PET, TRS-80.

    ERIC Educational Resources Information Center

    Olivero, James L.

    Each of the more than 200 educational software programs developed by both commercial and public domain sources which are described is intended for use with one of the four microcomputers most frequently used for instructional purposes--Atari, Apple, PET, and TRS-80. These descriptions are offered as a service for those who are just beginning to…

  19. 18 CFR 39.8 - Delegation to a Regional Entity.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Regional Entity. 39.8 Section 39.8 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... OF ELECTRIC RELIABILITY STANDARDS § 39.8 Delegation to a Regional Entity. (a) The Electric Reliability Organization may enter into an agreement to delegate authority to a Regional Entity for the...

  20. CREATION OF THE MODEL ADDITIONAL PROTOCOL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houck, F.; Rosenthal, M.; Wulf, N.

    In 1991, the international nuclear nonproliferation community was dismayed to discover that the implementation of safeguards by the International Atomic Energy Agency (IAEA) under its NPT INFCIRC/153 safeguards agreement with Iraq had failed to detect Iraq's nuclear weapon program. It was now clear that ensuring that states were fulfilling their obligations under the NPT would require not just detecting diversion but also the ability to detect undeclared materials and activities. To achieve this, the IAEA initiated what would turn out to be a five-year effort to reappraise the NPT safeguards system. The effort engaged the IAEA and its Member Statesmore » and led to agreement in 1997 on a new safeguards agreement, the Model Protocol Additional to the Agreement(s) between States and the International Atomic Energy Agency for the Application of Safeguards. The Model Protocol makes explicit that one IAEA goal is to provide assurance of the absence of undeclared nuclear material and activities. The Model Protocol requires an expanded declaration that identifies a State's nuclear potential, empowers the IAEA to raise questions about the correctness and completeness of the State's declaration, and, if needed, allows IAEA access to locations. The information required and the locations available for access are much broader than those provided for under INFCIRC/153. The negotiation was completed in quite a short time because it started with a relatively complete draft of an agreement prepared by the IAEA Secretariat. This paper describes how the Model Protocol was constructed and reviews key decisions that were made both during the five-year period and in the actual negotiation.« less

  1. 29 CFR 1910.381-1910.398 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 5 2011-07-01 2011-07-01 false [Reserved] 1910.381-1910.398 Section 1910.381-1910.398 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Electrical Safety Requirements for Special...

  2. 29 CFR 1910.381-1910.398 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false [Reserved] 1910.381-1910.398 Section 1910.381-1910.398 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Electrical Safety Requirements for Special...

  3. 40 CFR 60.398 - Innovative technology waivers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Innovative technology waivers. 60.398... Light Duty Truck Surface Coating Operations § 60.398 Innovative technology waivers. (a) General Motors... the emission limits in paragraph (a)(1)(ii)(A) of this section. (v) A technology development report...

  4. 40 CFR 60.398 - Innovative technology waivers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Innovative technology waivers. 60.398... Light Duty Truck Surface Coating Operations § 60.398 Innovative technology waivers. (a) General Motors... the emission limits in paragraph (a)(1)(ii)(A) of this section. (v) A technology development report...

  5. 40 CFR 60.398 - Innovative technology waivers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Innovative technology waivers. 60.398... Light Duty Truck Surface Coating Operations § 60.398 Innovative technology waivers. (a) General Motors... the emission limits in paragraph (a)(1)(ii)(A) of this section. (v) A technology development report...

  6. 14 CFR 398.5 - Frequency of flights.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Frequency of flights. 398.5 Section 398.5... flights. (a) Except in Alaska, at least two round trips each weekday and two round trips each weekend. (b...; (2) More flights are needed because the capacity available to the eligible place is being shared with...

  7. 14 CFR 398.5 - Frequency of flights.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Frequency of flights. 398.5 Section 398.5... flights. (a) Except in Alaska, at least two round trips each weekday and two round trips each weekend. (b...; (2) More flights are needed because the capacity available to the eligible place is being shared with...

  8. 14 CFR 398.5 - Frequency of flights.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Frequency of flights. 398.5 Section 398.5... flights. (a) Except in Alaska, at least two round trips each weekday and two round trips each weekend. (b...; (2) More flights are needed because the capacity available to the eligible place is being shared with...

  9. 14 CFR 398.5 - Frequency of flights.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Frequency of flights. 398.5 Section 398.5... flights. (a) Except in Alaska, at least two round trips each weekday and two round trips each weekend. (b...; (2) More flights are needed because the capacity available to the eligible place is being shared with...

  10. 47 CFR 52.34 - Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and from interconnected VoIP or Internet-based TRS providers. 52.34 Section 52.34 Telecommunication... Portability § 52.34 Obligations regarding local number porting to and from interconnected VoIP or Internet... customer's or a Registered Internet-based TRS User's valid number portability request, as it is defined in...

  11. 47 CFR 52.34 - Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and from interconnected VoIP or Internet-based TRS providers. 52.34 Section 52.34 Telecommunication... Portability § 52.34 Obligations regarding local number porting to and from interconnected VoIP or Internet... customer's or a Registered Internet-based TRS User's valid number portability request, as it is defined in...

  12. 47 CFR 52.34 - Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and from interconnected VoIP or Internet-based TRS providers. 52.34 Section 52.34 Telecommunication... Portability § 52.34 Obligations regarding local number porting to and from interconnected VoIP or Internet... customer's or a Registered Internet-based TRS User's valid number portability request, as it is defined in...

  13. 49 CFR 398.7 - Inspection and maintenance of motor vehicles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Inspection and maintenance of motor vehicles. 398.7 Section 398.7 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS TRANSPORTATION OF MIGRANT WORKERS § 398.7...

  14. 47 CFR 52.34 - Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and from interconnected VoIP or Internet-based TRS providers. 52.34 Section 52.34 Telecommunication... Portability § 52.34 Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS providers. (a) An interconnected VoIP or VRS or IP Relay provider must facilitate an end-user...

  15. 47 CFR 52.34 - Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and from interconnected VoIP or Internet-based TRS providers. 52.34 Section 52.34 Telecommunication... Portability § 52.34 Obligations regarding local number porting to and from interconnected VoIP or Internet-based TRS providers. (a) An interconnected VoIP or VRS or IP Relay provider must facilitate an end-user...

  16. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    NASA Astrophysics Data System (ADS)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  17. 14 CFR 398.8 - Number of intermediate stops.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Number of intermediate stops. 398.8 Section 398.8 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION... Number of intermediate stops. (a) Except in Alaska, no more than one intermediate stop is permitted in...

  18. 14 CFR 398.8 - Number of intermediate stops.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Number of intermediate stops. 398.8 Section 398.8 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION... Number of intermediate stops. (a) Except in Alaska, no more than one intermediate stop is permitted in...

  19. 50 CFR 660.398 - EFH Conservation Areas off the Coast of Oregon.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Oregon. 660.398 Section 660.398 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL... West Coast Groundfish Fisheries § 660.398 EFH Conservation Areas off the Coast of Oregon. Boundary line coordinates for EFH Conservation Areas off Oregon are provided in this § 660.398. Fishing activity that is...

  20. 49 CFR 398.4 - Driving of motor vehicles.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...

  1. 49 CFR 398.4 - Driving of motor vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...

  2. 49 CFR 398.4 - Driving of motor vehicles.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...

  3. 49 CFR 398.4 - Driving of motor vehicles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...

  4. 49 CFR 398.4 - Driving of motor vehicles.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...

  5. A new linear least squares method for T1 estimation from SPGR signals with multiple TRs

    NASA Astrophysics Data System (ADS)

    Chang, Lin-Ching; Koay, Cheng Guan; Basser, Peter J.; Pierpaoli, Carlo

    2009-02-01

    The longitudinal relaxation time, T1, can be estimated from two or more spoiled gradient recalled echo x (SPGR) images with two or more flip angles and one or more repetition times (TRs). The function relating signal intensity and the parameters are nonlinear; T1 maps can be computed from SPGR signals using nonlinear least squares regression. A widely-used linear method transforms the nonlinear model by assuming a fixed TR in SPGR images. This constraint is not desirable since multiple TRs are a clinically practical way to reduce the total acquisition time, to satisfy the required resolution, and/or to combine SPGR data acquired at different times. A new linear least squares method is proposed using the first order Taylor expansion. Monte Carlo simulations of SPGR experiments are used to evaluate the accuracy and precision of the estimated T1 from the proposed linear and the nonlinear methods. We show that the new linear least squares method provides T1 estimates comparable in both precision and accuracy to those from the nonlinear method, allowing multiple TRs and reducing computation time significantly.

  6. Evaluation of the Bess TRS-CA Using the Rasch Rating Scale Model

    ERIC Educational Resources Information Center

    DiStefano, Christine; Morgan, Grant B.

    2010-01-01

    This study examined the Behavioral and Emotional Screening System Teacher Rating System for Children and Adolescents (BESS TRS-CA; Kamphaus & Reynolds, 2007) screener using Rasch Rating Scale model (RSM) methodology to provide additional information about psychometric properties of items. Data from the Behavioral Assessment System for Children…

  7. Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.

    PubMed

    Pimpinella, M; Mihailescu, D; Guerra, A S; Laitano, R F

    2007-10-21

    Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-operative radiation therapy (IORT). The electron beam simulations were verified by comparing the measured dose distributions with the corresponding calculated distributions. As expected, a considerable difference was observed in the energy and angular distributions between the IORT beams studied in the present work and the electron beams produced by conventional accelerators for non-IORT applications. It was also found that significant differences exist between the IORT beams used in this work and other IORT beams with different collimation systems. For example, the contribution from the scattered electrons to the total dose was found to be up to 15% higher in the NOVAC7 beams. The water-to-air stopping power ratios of the IORT beams used in this work were calculated on the basis of the beam energy distributions obtained by the Monte Carlo simulations. These calculated stopping power ratios, s(w,air), were compared with the corresponding s(w,air) values recommended by the TRS-381 and TRS-398 IAEA dosimetry protocols in order to estimate the deviations between a dosimetry based on generic parameters and a dosimetry based on parameters specifically obtained for the actual IORT beams. The deviations in the s(w,air) values were found to be as large as up to about 1%. Therefore, we recommend that a preliminary analysis should always be made when dealing with IORT beams in order to assess to what extent the possible differences in the s(w,air) values have to be accounted for or may be neglected on the basis of the specific accuracy needed in clinical dosimetry.

  8. In modern linacs monitor units should be defined in water at 10 cm depth rather than at dmax.

    PubMed

    Van den Heuvel, Frank; Wu, Qiuwen; Cai, Jing

    2018-05-28

    Thanks to the widely adopted guidelines such as AAPM TG-51 1 and IAEA TRS-398 2 , linac calibration has become more consistent and accurate around the globe than previously. Modern linac photon beams are often calibrated in water at 10 cm depth, and configured such that 1 monitor unit (MU) corresponds to 1 cGy at the depth of maximum dose, (d max) . However, such configuration is not without limitations. Some think it is unnecessarily complex and prone to errors, and believe that defining MU at 10 cm is more appropriate. Others think that change of MU definition can cause confusion and possibly serious consequences without any real benefit. This is the premise debated in this month's Point/Counterpoint. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Dosimetry of Al2O3 optically stimulated luminescent dosimeter at high energy photons and electrons

    NASA Astrophysics Data System (ADS)

    Yusof, M. F. Mohd; Joohari, N. A.; Abdullah, R.; Shukor, N. S. Abd; Kadir, A. B. Abd; Isa, N. Mohd

    2018-01-01

    The linearity of Al2O3 OSL dosimeters (OSLD) were evaluated for dosimetry works in clinical photons and electrons. The measurements were made at a reference depth of Zref according to IAEA TRS 398:2000 codes of practice at 6 and 10 MV photons and 6 and 9 MeV electrons. The measured dose was compared to the thermoluminescence dosimeters (TLD) and ionization chamber commonly used for dosimetry works for higher energy photons and electrons. The results showed that the measured dose in OSL dosimeters were in good agreement with the reported by the ionization chamber in both high energy photons and electrons. A reproducibility test also reported excellent consistency of readings with the OSL at similar energy levels. The overall results confirmed the suitability of OSL dosimeters for dosimetry works involving high energy photons and electrons in radiotherapy.

  10. Methicillin-Resistant Staphylococcus aureus ST398 from Human Patients, Upper Austria

    PubMed Central

    Metz-Gercek, Sigrid; Mittermayer, Helmut

    2009-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) clonal type ST398 is usually associated with animals. We examined 1,098 confirmed MRSA samples from human patients and found that 21 were MRSA ST398. Most (16) patients were farmers. Increasing prevalence from 1.3% (2006) to 2.5% (2008) shows emergence of MRSA ST398 in humans in Austria. PMID:19402964

  11. Key process indicators of mortality in the implementation of protocol-driven therapy for severe sepsis.

    PubMed

    Wang, Jiun-Long; Chin, Chun-Shih; Chang, Ming-Chen; Yi, Chi-Yuan; Shih, Sou-Jen; Hsu, Jeng-Yuan; Wu, Chieh-Liang

    2009-10-01

    Severe sepsis and septic shock are life-threatening disorders. Integrating treatments into a bundle strategy has been proposed to facilitate timely resuscitation, but is difficult to implement. We implemented protocol-driven therapy for severe sepsis, and analyzed retrospectively the key process indicators of mortality in managing sepsis. Continuous quality improvement was begun to implement a tailored protocol-driven therapy for sepsis in a 24-bed respiratory intensive care unit (RICU) of Taichung Veterans General Hospital from January 2007 to February 2008. Patients, who were admitted to the RICU directly, or within 24 hours, were enrolled if they met the criteria for severe sepsis and septic shock. Disease severity [Acute Physiology and Chronic Health Evaluation (APACHE) II and lactate level], causes of sepsis, comorbidity and site of sepsis onset were recorded. Process-of-care indicators included resuscitation time (Tr-s), RICU bed availability (Ti-s) and the ratio of completing the elements of the protocol at 1, 2, 4 and 6 hours. The structure and process-of-care indicators reflated to mortality at 7 days after RICU admission and at RICU discharge were identified retrospectively. Eighty-six patients (mean age, 71 +/- 14 years, 72 men, 14 women, APACHE II, 25.0 +/- 7.0) were enrolled. APACHE II scores and lactate levels were higher for mortality than survival at 7 days after RICU admission (p < 0.01). For the process-of-care indicators, Ti-s (562.2 +/- 483.3 vs.1017.3 +/- 557.8 minutes, p = 0.03) and Tr-s (60.7 +/- 207.8 vs. 248.5 +/- 453.1 minutes, p = 0.07) were shorter for survival than mortality at 7 days after RICU admission. The logistic regression study showed that Tr-s was an important indicator. The ratio of completing the elements of protocols at 1, 2, 4 and 6 hours ranged from 70% to 90% and was not related to mortality. Protocol-driven therapy for sepsis was put into clinical practice. Early resuscitation and ICU bed availability were key process

  12. Methicillin-Resistant and -Susceptible Staphylococcus aureus Sequence Type 398 in Pigs and Humans

    PubMed Central

    van Belkum, Alex; Peeters, Justine K.; van Leeuwen, Willem B.; van Duijkeren, Engeline; Huijsdens, Xander W.; Spalburg, Emile; de Neeling, Albert J.; Verbrugh, Henri A.

    2008-01-01

    Methicillin-resistant Staphylococcus aureus sequence type 398 (ST398 MRSA) was identified in Dutch pigs and pig farmers. ST398 methicillin-susceptible S. aureus circulates among humans at low frequency (0.2%) but was isolated in 3 human cases of bacteremia (2.1%; p = 0.026). Although its natural host is probably porcine, ST398 MRSA likely causes infections in humans. PMID:18325267

  13. The design and dosimetric evaluation of tannin-based Rhizophora spp. particleboards as phantoms for high energy photons and electrons

    NASA Astrophysics Data System (ADS)

    Yusof, M. F. Mohd; Abdullah, R.; Tajuddin, A. A.; Hashim, R.; Bauk, S.; Hamid, P. N. K. Abd

    2018-01-01

    A set of phantom with an external dimension of 30 cm x 30 cm was constructed from tannin-based Rhizophora spp. particleboards similar to the solid water phantoms. The dosimetric characteristics of the particleboard phantoms were evaluated at high energy photons and electrons by measuring the beam output at 6 MV photons and 6 MeV electrons based on the IAEA TRS 398:2000 protocol. The tissue-phantom ratio (TPR20,10) was measured at 6 and 10 MV photons. The beam output calibration of the particleboards was in good agreement to water and solid water phantoms at 6 MV photons with percentage difference of 1.7 and 6.2% respectively. The beam output calibration of the tannin-based Rhizophora spp. particleboards at 6 MeV electrons on the other hand were in excellent agreement to water with percentage difference of 0.3. The percentage depth dose of tannin-based Rhizophora spp. particleboards were in agreement to water and solid water within 4.5% when measured using ionization chamber and EBT2 film. The electron beam parameters of R50, R80 and R90 at 6 MeV electrons also were in good agreement to water and solid water phantoms. The overall results had indicated the suitability of tannin-based Rhizophora spp. particleboards as water substitute phantom materials for high energy photons and electrons.

  14. 40 CFR 98.398 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... or delivered as undifferentiated product. Natural Gas Liquids (NGLs) for the purposes of reporting under this subpart means hydrocarbons that are separated from natural gas as liquids through the process... GREENHOUSE GAS REPORTING Suppliers of Petroleum Products § 98.398 Definitions. Except as specified in this...

  15. 47 CFR 64.606 - VRS and IP Relay provider and TRS program certification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false VRS and IP Relay provider and TRS program... Services and Related Customer Premises Equipment for Persons With Disabilities § 64.606 VRS and IP Relay... including notification in the Federal Register. (2) VRS and IP Relay provider. Any entity desiring to...

  16. SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorriaux, J; Lee, J; ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve

    2015-06-15

    Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combinemore » many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the

  17. 40 CFR 98.398 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GREENHOUSE GAS REPORTING Suppliers of Petroleum Products § 98.398 Definitions. All terms used in this subpart... MM-1 Table MM-1 to Subpart MM of Part 98—Default Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl) Column B:carbon share (% of mass) Column C...

  18. Rapid Differentiation between Livestock-Associated and Livestock-Independent Staphylococcus aureus CC398 Clades

    PubMed Central

    Larsen, Jesper; Soldanova, Katerina; Aziz, Maliha; Contente-Cuomo, Tania; Petersen, Andreas; Vandendriessche, Stien; Jiménez, Judy N.; Mammina, Caterina; van Belkum, Alex; Salmenlinna, Saara; Laurent, Frederic; Skov, Robert L.; Larsen, Anders R.; Andersen, Paal S.; Price, Lance B.

    2013-01-01

    Staphylococcus aureus clonal complex 398 (CC398) isolates cluster into two distinct phylogenetic clades based on single-nucleotide polymorphisms (SNPs) revealing a basal human clade and a more derived livestock clade. The scn and tet(M) genes are strongly associated with the human and the livestock clade, respectively, due to loss and acquisition of mobile genetic elements. We present canonical single-nucleotide polymorphism (canSNP) assays that differentiate the two major host-associated S. aureus CC398 clades and a duplex PCR assay for detection of scn and tet(M). The canSNP assays correctly placed 88 S. aureus CC398 isolates from a reference collection into the human and livestock clades and the duplex PCR assay correctly identified scn and tet(M). The assays were successfully applied to a geographically diverse collection of 272 human S. aureus CC398 isolates. The simple assays described here generate signals comparable to a whole-genome phylogeny for major clade assignment and are easily integrated into S. aureus CC398 surveillance programs and epidemiological studies. PMID:24244535

  19. 49 CFR 398.8 - Administration inspection of motor vehicles in operation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Administration inspection of motor vehicles in operation. 398.8 Section 398.8 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS TRANSPORTATION OF MIGRANT WORKERS ...

  20. 49 CFR 398.5 - Parts and accessories necessary for safe operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... inches of space between the backrests or between the edges of the opposite seats when face to face.... 398.5 Section 398.5 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL... vehicle, or cause or permit it to be operated, unless it is equipped in accordance with said requirements...

  1. Impact of age on the selection of nuclear cardiology stress protocols: The INCAPS (IAEA nuclear cardiology protocols) study.

    PubMed

    Al-Mallah, Mouaz H; Pascual, Thomas N B; Mercuri, Mathew; Vitola, João V; Karthikeyan, Ganesan; Better, Nathan; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    2018-05-15

    There is growing concern about radiation exposure from nuclear myocardial perfusion imaging (MPI), particularly among younger patients who are more prone to develop untoward effects of ionizing radiation, and hence US and European professional society guidelines recommend age as a consideration in weighing radiation risk from MPI. We aimed to determine how patient radiation doses from MPI vary across age groups in a large contemporary international cohort. Data were collected as part of a global cross-sectional study of centers performing MPI coordinated by the International Atomic Energy Agency (IAEA). Sites provided information on each MPI study completed during a single week in March-April 2013. We compared across age groups laboratory adherence to pre-specified radiation-related best practices, radiation effective dose (ED; a whole-body measure reflecting the amount of radiation to each organ and its relative sensitivity to radiation's deleterious effects), and the proportion of patients with ED ≤ 9 mSv, a target level specified in guidelines. Among 7911 patients undergoing MPI in 308 laboratories in 65 countries, mean ED was 10.0 ± 4.5 mSv with slightly higher exposure among younger age groups (trend p value < 0.001). There was no difference in the proportion of patients with ED ≤ 9 mSv across age groups, or in adherence to best practices based on the median age of patients in a laboratory. In contemporary nuclear cardiology practice, the age of the patient appears not to impact protocol selection and radiation dose, contrary to professional society guidelines. Copyright © 2018. Published by Elsevier B.V.

  2. SU-F-T-174: Patient-Specific Point Dose Measurement Using Fiber Optic Radiation Sensor Using Cerenkov Radiation for Proton Therapeutic Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Son, J; National Cancer Center, Goyang-si; Kim, M

    Purpose: A fiber-optic radiation sensor using Cerenkov radiation (FOCR) has been widely studied for use as a dosimeter for proton therapeutic beam. We developed the FOCR, and it applied to patient-specific point dose measurement in order to evaluate the effectiveness of the FOCR system for proton therapy QA. Methods: Calibration of FOCR was performed with an ionization chamber whose absolute doses were determined according to the IAEA TRS-398 protocol. To determine the calibration curve, the FOCR was irradiated perpendicularly to the proton beam at the 13 dose levels steps. We selected five actual patient treatment plans performed at proton therapymore » center and compared the resulting FOCR measurements with the ionization chamber measurements. Results: The Cerenkov light yield of the FOCR increases linearly with as the dose measured using the ionization chamber increases from 0 cGy to 500 cGy. The results indicate that the fitting curve is linear, suggesting that dose measurement based on the light yield of the FOCR is possible. The results of proton radiation dose QA performed using the FOCR for 10 proton fields and five patients are good agreement with an ionization chamber. Conclusion: We carried out the patient QA using the FOCR for proton therapeutic beam and evaluated the effectiveness of the FOCR as a proton therapy QA tool. Our results indicate that the FOCR is suitable for use in patient QA of clinical proton beams.« less

  3. On the p(dis) correction factor for cylindrical chambers.

    PubMed

    Andreo, Pedro

    2010-03-07

    The authors of a recent paper (Wang and Rogers 2009 Phys. Med. Biol. 54 1609) have used the Monte Carlo method to simulate the 'classical' experiment made more than 30 years ago by Johansson et al (1978 National and International Standardization of Radiation Dosimetry (Atlanta 1977) vol 2 (Vienna: IAEA) pp 243-70) on the displacement (or replacement) perturbation correction factor p(dis) for cylindrical chambers in 60Co and high-energy photon beams. They conclude that an 'unreasonable normalization at dmax' of the ionization chambers response led to incorrect results, and for the IAEA TRS-398 Code of Practice, which uses ratios of those results, 'the difference in the correction factors can lead to a beam calibration deviation of more than 0.5% for Farmer-like chambers'. The present work critically examines and questions some of the claims and generalized conclusions of the paper. It is demonstrated that for real, commercial Farmer-like chambers, the possible deviations in absorbed dose would be much smaller (typically 0.13%) than those stated by Wang and Rogers, making the impact of their proposed values negligible on practical high-energy photon dosimetry. Differences of the order of 0.4% would only appear at the upper extreme of the energies potentially available for clinical use (around 25 MV) and, because lower energies are more frequently used, the number of radiotherapy photon beams for which the deviations would be larger than say 0.2% is extremely small. This work also raises concerns on the proposed value of pdis for Farmer chambers at the reference quality of 60Co in relation to their impact on electron beam dosimetry, both for direct dose determination using these chambers and for the cross-calibration of plane-parallel chambers. The proposed increase of about 1% in p(dis) (compared with TRS-398) would lower the kQ factors and therefore Dw in electron beams by the same amount. This would yield a severe discrepancy with the current good agreement between

  4. LETTER TO THE EDITOR: On the pdis correction factor for cylindrical chambers

    NASA Astrophysics Data System (ADS)

    Andreo, Pedro

    2010-03-01

    The authors of a recent paper (Wang and Rogers 2009 Phys. Med. Biol. 54 1609) have used the Monte Carlo method to simulate the 'classical' experiment made more than 30 years ago by Johansson et al (1978 National and International Standardization of Radiation Dosimetry (Atlanta 1977) vol 2 (Vienna: IAEA) pp 243-70) on the displacement (or replacement) perturbation correction factor pdis for cylindrical chambers in 60Co and high-energy photon beams. They conclude that an 'unreasonable normalization at dmax' of the ionization chambers response led to incorrect results, and for the IAEA TRS-398 Code of Practice, which uses ratios of those results, 'the difference in the correction factors can lead to a beam calibration deviation of more than 0.5% for Farmer-like chambers'. The present work critically examines and questions some of the claims and generalized conclusions of the paper. It is demonstrated that for real, commercial Farmer-like chambers, the possible deviations in absorbed dose would be much smaller (typically 0.13%) than those stated by Wang and Rogers, making the impact of their proposed values negligible on practical high-energy photon dosimetry. Differences of the order of 0.4% would only appear at the upper extreme of the energies potentially available for clinical use (around 25 MV) and, because lower energies are more frequently used, the number of radiotherapy photon beams for which the deviations would be larger than say 0.2% is extremely small. This work also raises concerns on the proposed value of pdis for Farmer chambers at the reference quality of 60Co in relation to their impact on electron beam dosimetry, both for direct dose determination using these chambers and for the cross-calibration of plane-parallel chambers. The proposed increase of about 1% in pdis (compared with TRS-398) would lower the kQ factors and therefore Dw in electron beams by the same amount. This would yield a severe discrepancy with the current good agreement between

  5. Validating the BASC-TRS for Use with Children and Adolescents with an Educational Diagnosis of Autism

    ERIC Educational Resources Information Center

    Hass, Michael R.; Brown, Richard S.; Brady, John; Johnson, Danielle Boehm

    2012-01-01

    Accurate diagnosis and treatment planning for children with autism are a growing concern. This study sought to address two questions: (a) Which domains of the of the "Behavior Assessment System for Children" (2nd ed.) Teacher Rating Scales (BASC-TRS) are most effective in discriminating students diagnosed with higher functioning autism…

  6. Publications - GMC 398 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 398 Publication Details Title: Porosity and permeability, core sample photos from five Cook from five Cook Inlet basin wells: Deep Creek #1-RD, Foreland Channel State #1-A, Redoubt Unit #5A

  7. Identification of a Highly Transmissible Animal-Independent Staphylococcus aureus ST398 Clone with Distinct Genomic and Cell Adhesion Properties

    PubMed Central

    Uhlemann, Anne-Catrin; Porcella, Stephen F.; Trivedi, Sheetal; Sullivan, Sean B.; Hafer, Cory; Kennedy, Adam D.; Barbian, Kent D.; McCarthy, Alex J.; Street, Craig; Hirschberg, David L.; Lipkin, W. Ian; Lindsay, Jodi A.; DeLeo, Frank R.; Lowy, Franklin D.

    2012-01-01

    ABSTRACT A methicillin-resistant Staphylococcus aureus (MRSA) clone known as ST398 has emerged as a major cause of acute infections in individuals who have close contact with livestock. More recently, the emergence of an animal-independent ST398 methicillin-sensitive S. aureus (MSSA) clone has been documented in several countries. However, the limited surveillance of MSSA has precluded an accurate assessment of the global spread of ST398 and its clinical relevance. Here we provide evidence that ST398 is a frequent source of MSSA infections in northern Manhattan and is readily transmitted between individuals in households. This contrasts with the limited transmissibility of livestock-associated ST398 (LA-ST398) MRSA strains between humans. Our whole-genome sequence analysis revealed that the chromosome of the human-associated ST398 MSSA clone is smaller than that of the LA-ST398 MRSA reference strain S0385, due mainly to fewer mobile genetic elements (MGEs). In contrast, human ST398 MSSA isolates harbored the prophage φ3 and the human-specific immune evasion cluster (IEC) genes chp and scn. While most of the core genome was conserved between the human ST398 MSSA clone and S0385, these strains differed substantially in their repertoire and composition of intact adhesion genes. These genetic changes were associated with significantly enhanced adhesion of human ST398 MSSA isolates to human skin keratinocytes and keratin. We propose that the human ST398 MSSA clone can spread independent of animal contact using an optimized repertoire of MGEs and adhesion molecules adapted to transmission among humans. PMID:22375071

  8. Detection of livestock-associated meticillin-resistant Staphylococcus aureus CC398 in retail pork, United Kingdom, February 2015

    PubMed Central

    Hadjirin, N F; Lay, E M; Paterson, G K; Harrison, E M; Peacock, S J; Parkhill, J; Zadoks, R N

    2016-01-01

    Livestock-associated meticillin-resistant Staphylococcus aureus belonging to clonal complex 398 (LA-MRSA CC398) is an important cause of zoonotic infections in many countries. Here, we describe the isolation of LA-MRSA CC398 from retail meat samples of United Kingdom (UK) farm origin. Our findings indicate that this lineage is probably established in UK pig farms and demonstrate a potential pathway for the transmission of LA-MRSA CC398 from livestock to humans in the UK. PMID:26111237

  9. SU-E-T-146: Reference Dosimetry for Protons and Light-Ion Beams Based on Graphite Calorimetry.

    PubMed

    Rossomme, S; Palmans, H; Thomas, R; Lee, N; Bailey, M; Shipley, D; Al-Sulaiti, L; Cirrone, P; Romano, F; Kacperek, A; Bertrand, D; Vynckier, S

    2012-06-01

    The IAEA TRS-398 code of practice can be applied for the measurement of absorbed dose to water under reference conditions with an ionization chamber. For protons, the combined relative standard uncertainty on those measurements is less than 2% while for light-ion beams, it is considerably larger, i.e. 3.2%, mainly due to the higher uncertainty contributions for the water to air stopping power ration and the W air-value on the beam quality correction factors kQ,Q 0 . To decrease this uncertainty, a quantification of kQ,Q 0 is proposed using a primary standard level graphite calorimeter. This work includes numerical and experimental determinations of dose conversion factors to derive dose to water from graphite calorimetry. It also reports on the first experimental data obtained with the graphite calorimeter in proton, alpha and carbon ion beams. Firstly, the dose conversion has been calculated with by Geant4 Monte-Carlo simulations through the determination of the water to graphite stopping power ratio and the fluence correction factor. The latter factor was also derived by comparison of measured ionization curves in graphite and water. Secondly, kQ,Q 0 was obtained by comparison of the dose response of ionization chambers with that of the calorimeter. Stopping power ratios are found to vary by no more than 0.35% up to the Bragg peak, while fluence correction factors are shown to increase slightly above unity close to the Bragg peak. The comparison of the calorimeter with ionization chambers is currently under analysis. For the modulated proton beam, preliminary results on W air confirm the value recommended in TRS-398. Data in both the non-modulated proton and light-ion beams indicate higher values but further investigation of heat loss corrections is needed. The application of graphite calorimetry to proton, alpha and carbon ion beams has been demonstrated successfully. Other experimental campaigns will be held in 2012. This work is supported by the BioWin program

  10. Colonization and Transmission of Methicillin-Resistant Staphylococcus aureus ST398 in Nursery Piglets

    PubMed Central

    Vanderhaeghen, Wannes; Dewulf, Jeroen; Hermans, Katleen; Haesebrouck, Freddy; Butaye, Patrick

    2012-01-01

    A transmission experiment was performed to evaluate the spread of methicillin-resistant Staphylococcus aureus (MRSA) ST398 in nursery piglets. Reproduction ratios (R0) in three experimental groups were found to vary between 3.92 and 52.54, indicating that after introduction, MRSA ST398 will spread easily among weaned piglets, with a tendency to become established. PMID:22194292

  11. Assessment of ionization chamber correction factors in photon beams using a time saving strategy with PENELOPE code.

    PubMed

    Reis, C Q M; Nicolucci, P

    2016-02-01

    The purpose of this study was to investigate Monte Carlo-based perturbation and beam quality correction factors for ionization chambers in photon beams using a saving time strategy with PENELOPE code. Simulations for calculating absorbed doses to water using full spectra of photon beams impinging the whole water phantom and those using a phase-space file previously stored around the point of interest were performed and compared. The widely used NE2571 ionization chamber was modeled with PENELOPE using data from the literature in order to calculate absorbed doses to the air cavity of the chamber. Absorbed doses to water at reference depth were also calculated for providing the perturbation and beam quality correction factors for that chamber in high energy photon beams. Results obtained in this study show that simulations with phase-space files appropriately stored can be up to ten times shorter than using a full spectrum of photon beams in the input-file. Values of kQ and its components for the NE2571 ionization chamber showed good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Comparisons to kQ values published in current dosimetry protocols such as the AAPM TG-51 and IAEA TRS-398 showed maximum percentage differences of 0.1% and 0.6% respectively. The proposed strategy presented a significant efficiency gain and can be applied for a variety of ionization chambers and clinical photon beams. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krylova, T.

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  13. TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  14. TH-EF-204-06: Closing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borras, C.

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  15. TH-EF-204-01: Introduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cygler, J.

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  16. TH-EF-204-03: Determination of Small Field Output Factors, Advantages and Limitations of Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaque, J. Puxeu

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  17. TH-EF-204-05: Application of Small-Field Treatment: The Promises and Pitfalls of SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, E.

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment deliverymore » systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in

  18. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R. E., E-mail: drzymala@wustl.edu; Alvarez, P. E.; Bednarz, G.

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods:more » Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG

  19. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service.

    PubMed

    Jangda, Abdul Qadir; Hussein, Sherali

    2012-05-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility.

  20. 49 CFR 398.7 - Inspection and maintenance of motor vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REGULATIONS TRANSPORTATION OF MIGRANT WORKERS § 398.7 Inspection and maintenance of motor vehicles. Every... motor vehicles and their accessories subject to its control, to insure that such motor vehicles and...

  1. School Microware Reviews. Evaluations of Educational Software for Apple, PET, TRS-80, with Index to Evaluations in Other Publications.

    ERIC Educational Resources Information Center

    School Microware Reviews, 1981

    1981-01-01

    This document describes the operation and quality of pre-college instructional software sold for use on microcomputers. It also assists in locating other sources of similar information about instructional software. This edition is limited to programs for the Apple II, Commodore PET, and Radio Shack TRS-80 Model I. Fifty reviews of software…

  2. TU-G-BRD-04: A Round Robin Dosimetry Intercomparison of Gamma Stereotactic Radiosurgery Calibration Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drzymala, R; Alvarez, P; Bednarz, G

    2015-06-15

    Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula

  3. Tyrosine kinase inhibitor NVP-BGJ398 functionally improves FGFR3-related dwarfism in mouse model.

    PubMed

    Komla-Ebri, Davide; Dambroise, Emilie; Kramer, Ina; Benoist-Lasselin, Catherine; Kaci, Nabil; Le Gall, Cindy; Martin, Ludovic; Busca, Patricia; Barbault, Florent; Graus-Porta, Diana; Munnich, Arnold; Kneissel, Michaela; Di Rocco, Federico; Biosse-Duplan, Martin; Legeai-Mallet, Laurence

    2016-05-02

    Achondroplasia (ACH) is the most frequent form of dwarfism and is caused by gain-of-function mutations in the fibroblast growth factor receptor 3-encoding (FGFR3-encoding) gene. Although potential therapeutic strategies for ACH, which aim to reduce excessive FGFR3 activation, have emerged over many years, the use of tyrosine kinase inhibitor (TKI) to counteract FGFR3 hyperactivity has yet to be evaluated. Here, we have reported that the pan-FGFR TKI, NVP-BGJ398, reduces FGFR3 phosphorylation and corrects the abnormal femoral growth plate and calvaria in organ cultures from embryos of the Fgfr3Y367C/+ mouse model of ACH. Moreover, we demonstrated that a low dose of NVP-BGJ398, injected subcutaneously, was able to penetrate into the growth plate of Fgfr3Y367C/+ mice and modify its organization. Improvements to the axial and appendicular skeletons were noticeable after 10 days of treatment and were more extensive after 15 days of treatment that started from postnatal day 1. Low-dose NVP-BGJ398 treatment reduced intervertebral disc defects of lumbar vertebrae, loss of synchondroses, and foramen-magnum shape anomalies. NVP-BGJ398 inhibited FGFR3 downstream signaling pathways, including MAPK, SOX9, STAT1, and PLCγ, in the growth plates of Fgfr3Y367C/+ mice and in cultured chondrocyte models of ACH. Together, our data demonstrate that NVP-BGJ398 corrects pathological hallmarks of ACH and support TKIs as a potential therapeutic approach for ACH.

  4. Draft genome sequences of 14 swine associated LA-MRSA ST398 isolates from the U.S.

    USDA-ARS?s Scientific Manuscript database

    Livestock associated methicillin resistant Staphylococcus aureus (LA-MRSA) is part of the normal microbiota of swine. The initial and predominant swine associated LA-MRSA sequence type (ST) identified is ST398. Here, we present 14 draft genome sequence from LA-MRSA ST398 isolates found in the US....

  5. 25 CFR 1000.398 - May a Tribe/Consortium invest funds received under a self-governance agreement?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false May a Tribe/Consortium invest funds received under a self-governance agreement? 1000.398 Section 1000.398 Indians OFFICE OF THE ASSISTANT SECRETARY, INDIAN AFFAIRS... invest funds received under a self-governance agreement? Yes, self-governance funds may be invested if...

  6. 14 CFR 135.398 - Commuter category airplanes performance operating limitations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Commuter category airplanes performance... ON BOARD SUCH AIRCRAFT Airplane Performance Operating Limitations § 135.398 Commuter category airplanes performance operating limitations. (a) No person may operate a commuter category airplane unless...

  7. 14 CFR 135.398 - Commuter category airplanes performance operating limitations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Commuter category airplanes performance... ON BOARD SUCH AIRCRAFT Airplane Performance Operating Limitations § 135.398 Commuter category airplanes performance operating limitations. (a) No person may operate a commuter category airplane unless...

  8. 14 CFR 135.398 - Commuter category airplanes performance operating limitations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Commuter category airplanes performance... ON BOARD SUCH AIRCRAFT Airplane Performance Operating Limitations § 135.398 Commuter category airplanes performance operating limitations. (a) No person may operate a commuter category airplane unless...

  9. 398. Delineator Unknown Date Unknown STATE OF CALIFORNIA; DEPARTMENT OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    398. Delineator Unknown Date Unknown STATE OF CALIFORNIA; DEPARTMENT OF PUBLIC WORKS; SAN FRANCISCO - OAKLAND BAY BRIDGE; EAST BAY CROSSING; GENERAL PLAN; TOWER E-9; DRG. NO. 59 - San Francisco Oakland Bay Bridge, Spanning San Francisco Bay, San Francisco, San Francisco County, CA

  10. Tyrosine kinase inhibitor NVP-BGJ398 functionally improves FGFR3-related dwarfism in mouse model

    PubMed Central

    Dambroise, Emilie; Kramer, Ina; Benoist-Lasselin, Catherine; Kaci, Nabil; Le Gall, Cindy; Martin, Ludovic; Busca, Patricia; Barbault, Florent; Graus-Porta, Diana; Munnich, Arnold; Kneissel, Michaela; Di Rocco, Federico; Biosse-Duplan, Martin

    2016-01-01

    Achondroplasia (ACH) is the most frequent form of dwarfism and is caused by gain-of-function mutations in the fibroblast growth factor receptor 3–encoding (FGFR3-encoding) gene. Although potential therapeutic strategies for ACH, which aim to reduce excessive FGFR3 activation, have emerged over many years, the use of tyrosine kinase inhibitor (TKI) to counteract FGFR3 hyperactivity has yet to be evaluated. Here, we have reported that the pan-FGFR TKI, NVP-BGJ398, reduces FGFR3 phosphorylation and corrects the abnormal femoral growth plate and calvaria in organ cultures from embryos of the Fgfr3Y367C/+ mouse model of ACH. Moreover, we demonstrated that a low dose of NVP-BGJ398, injected subcutaneously, was able to penetrate into the growth plate of Fgfr3Y367C/+ mice and modify its organization. Improvements to the axial and appendicular skeletons were noticeable after 10 days of treatment and were more extensive after 15 days of treatment that started from postnatal day 1. Low-dose NVP-BGJ398 treatment reduced intervertebral disc defects of lumbar vertebrae, loss of synchondroses, and foramen-magnum shape anomalies. NVP-BGJ398 inhibited FGFR3 downstream signaling pathways, including MAPK, SOX9, STAT1, and PLCγ, in the growth plates of Fgfr3Y367C/+ mice and in cultured chondrocyte models of ACH. Together, our data demonstrate that NVP-BGJ398 corrects pathological hallmarks of ACH and support TKIs as a potential therapeutic approach for ACH. PMID:27064282

  11. Emergence of methicillin-resistant Staphylococcus aureus from clonal complex 398 with no livestock association in Brazil

    PubMed Central

    André, Egidio Domingos; Pereira, Renata Freire Alves; Snyder, Robert Eugene; Machado, Thamiris Santana; André, Lialyz Soares Pereira; Cardoso, Claudete Aparecida Araújo; Aguiar-Alves, Fábio

    2017-01-01

    CC398 is a livestock-associated Staphylococcus aureus. However, it has also been isolated from humans with no previous contact with livestock. A surveillance of methicillin-resistant S. aureus colonisation among children attending public day care centres and hospitals in Niterói and Rio de Janeiro, Brazil, between 2011 and 2013, resulted in the isolation of six cases of CC398 from individuals with no previous exposure to livestock. These isolates showed a high frequency of the erm(C) gene (4/6, 66.7%) with induced resistance to clindamycin, and a relatively high frequency of SEs and lukS/lukF genes. These results suggest the emergence of a non-LA-CC398 in Brazil. PMID:28902291

  12. The first case of Staphylococcus aureus ST398 causing bacteremia in an immunocompromised patient in Greece.

    PubMed

    Drougka, E; Foka, A; Marangos, M N; Liakopoulos, A; Makatsoris, T; Anastassiou, E D; Petinaki, E; Spiliopoulou, I

    2012-01-01

    We describe a case of catheter-related bloodstream infection, in a patient with colon cancer, caused by a methicillin-sensitive Staphylococcus aureus strain, nontypeable by pulsed field gel electrophoresis of SmaI macrorestriction fragment analysis, belonging to ST398. The patient recovered after daptomycin therapy. This is the first report that documents the emergence of ST398 in Greece.

  13. 13 CFR 120.398 - America's Recovery Capital (ARC) Loan Program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13 Business Credit and Assistance 1 2011-01-01 2011-01-01 false America's Recovery Capital (ARC... BUSINESS LOANS Special Purpose Loans America's Recovery Capital (business Stabilization) Loan Program-Arc Loan Program § 120.398 America's Recovery Capital (ARC) Loan Program. (a) Purpose. The purpose of the...

  14. 13 CFR 120.398 - America's Recovery Capital (ARC) Loan Program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 13 Business Credit and Assistance 1 2014-01-01 2014-01-01 false America's Recovery Capital (ARC... BUSINESS LOANS Special Purpose Loans America's Recovery Capital (business Stabilization) Loan Program-Arc Loan Program § 120.398 America's Recovery Capital (ARC) Loan Program. (a) Purpose. The purpose of the...

  15. 13 CFR 120.398 - America's Recovery Capital (ARC) Loan Program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 13 Business Credit and Assistance 1 2013-01-01 2013-01-01 false America's Recovery Capital (ARC... BUSINESS LOANS Special Purpose Loans America's Recovery Capital (business Stabilization) Loan Program-Arc Loan Program § 120.398 America's Recovery Capital (ARC) Loan Program. (a) Purpose. The purpose of the...

  16. 13 CFR 120.398 - America's Recovery Capital (ARC) Loan Program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 13 Business Credit and Assistance 1 2012-01-01 2012-01-01 false America's Recovery Capital (ARC... BUSINESS LOANS Special Purpose Loans America's Recovery Capital (business Stabilization) Loan Program-Arc Loan Program § 120.398 America's Recovery Capital (ARC) Loan Program. (a) Purpose. The purpose of the...

  17. Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam

    NASA Astrophysics Data System (ADS)

    Rossomme, S.; Hopfgartner, J.; Vynckier, S.; Palmans, H.

    2016-06-01

    To investigate the linear energy transfer (LET) dependence of the response of a PTW-60019 Freiburg microDiamond detector, its response was compared to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Results obtained with two different experimental setups are in agreement. As recommended by IAEA TRS-398, the response of the Markus chamber was corrected for temperature, pressure, polarity effects and ion recombination. No correction was applied to the response of the microDiamond detector. The ratio of the response of the Markus chamber to the response of the microDiamond is close to unity in the plateau region. In the Bragg peak region, a significant increase of the ratio is observed, which increases to 1.2 in the distal edge region. Results indicate a correlation between the under-response of the microDiamond detector and high LET values. The combined relative standard uncertainty of the results is estimated to be 2.38% in the plateau region and 12% in the distal edge region. These values are dominated by the uncertainty of alignment in the non-uniform beam and the uncertainty of range determination.

  18. Nuclear Cardiology Practices and Radiation Exposure in the Oceania Region: Results From the IAEA Nuclear Cardiology Protocols Study (INCAPS).

    PubMed

    Biswas, Sinjini; Better, Nathan; Pascual, Thomas N B; Mercuri, Mathew; Vitola, João V; Karthikeyan, Ganesan; Westcott, James; Alexánderson, Erick; Allam, Adel H; Al-Mallah, Mouaz H; Bom, Henry Hee-Seung; Bouyoucef, Salah E; Flotats, Albert; Jerome, Scott; Kaufman, Philip A; Lele, Vikram; Luxenburg, Osnat; Mahmarian, John J; Shaw, Leslee J; Underwood, S Richard; Rehani, Madan; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    2017-01-01

    There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  19. Recommended observational skills training for IAEA safeguards inspections. Final report: Recommended observational skills training for IAEA safeguards inspections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toquam, J.L.; Morris, F.A.

    This is the second of two reports prepared to assist the International Atomic Energy Agency (IAEA or Agency) in enhancing the effectiveness of its international safeguards inspections through inspector training in {open_quotes}Observational Skills{close_quotes}. The first (Phase 1) report was essentially exploratory. It defined Observational Skills broadly to include all appropriate cognitive, communications, and interpersonal techniques that have the potential to help IAEA safeguards inspectors function more effectively. It identified 10 specific Observational Skills components, analyzed their relevance to IAEA safeguards inspections, and reviewed a variety of inspection programs in the public and private sectors that provide training in one ormore » more of these components. The report concluded that while it should be possible to draw upon these other programs in developing Observational Skills training for IAEA inspectors, the approaches utilized in these programs will likely require significant adaption to support the specific job requirements, policies, and practices that define the IAEA inspector`s job. The overall objective of this second (Phase 2) report is to provide a basis for the actual design and delivery of Observational Skills training to IAEA inspectors. The more specific purposes of this report are to convey a fuller understanding of the potential application of Observational Skills to the inspector`s job, describe inspector perspectives on the relevance and importance of particular Observational Skills, identify the specific Observational Skill components that are most important and relevant to enhancing safeguards inspections, and make recommendations as to Observational Skills training for the IAEA`s consideration in further developing its Safeguards training program.« less

  20. Improving the quantity, quality and transparency of data used to derive radionuclide transfer parameters for animal products. 2. Cow milk.

    PubMed

    Howard, B J; Wells, C; Barnett, C L; Howard, D C

    2017-02-01

    Under the International Atomic Energy Agency (IAEA) MODARIA (Modelling and Data for Radiological Impact Assessments) Programme, there has been an initiative to improve the derivation, provenance and transparency of transfer parameter values for radionuclides from feed to animal products that are for human consumption. A description of the revised MODARIA 2016 cow milk dataset is described in this paper. As previously reported for the MODARIA goat milk dataset, quality control has led to the discounting of some references used in IAEA's Technical Report Series (TRS) report 472 (IAEA, 2010). The number of Concentration Ratio (CR) values has been considerably increased by (i) the inclusion of more literature from agricultural studies which particularly enhanced the stable isotope data of both CR and F m and (ii) by estimating dry matter intake from assumed liveweight. In TRS 472, the data for cow milk were 714 transfer coefficient (F m ) values and 254 CR values describing 31 elements and 26 elements respectively. In the MODARIA 2016 cow milk dataset, F m and CR values are now reported for 43 elements based upon 825 data values for F m and 824 for CR. The MODARIA 2016 cow milk dataset F m values are within an order of magnitude of those reported in TRS 472. Slightly bigger changes are seen in the CR values, but the increase in size of the dataset creates greater confidence in them. Data gaps that still remain are identified for elements with isotopes relevant to radiation protection. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Commissioning and comprehensive quality assurance of commercial 3D treatment planning system using IAEA Technical Report Series-430.

    PubMed

    Jamema, S V; Upreti, R R; Sharma, S; Deshpande, D D

    2008-09-01

    The purpose of this work is to report the results of commissioning and to establish a quality assurance (QA) program for commercial 3D treatment planning system (TPS) based on IAEA Technical Report Series 430. Eclipse v 7.3.10, (Varian Medical Systems, Palo Alto, CA, U.S.A.) TPS was commissioned for a Clinac 6EX (Varian Medical Systems, Palo Alto, CA, USA) linear accelerator. CT images of a phantom with various known in-homogeneities were acquired. The images were transferred to TPS and tested for various parameters related to patient data acquisition, anatomical modeling, plan evaluation and dose calculation. Dosimetric parameters including open, asymmetric and wedged shaped fields, oblique incidence, buildup region behavior and SSD dependence were evaluated. Representative clinical cases were tested for MU calculation and point doses. The maximum variation between the measured and the known CT numbers was 20 +/- 11.7 HU (1 SD). The results of all non-dosimetric tests were found within tolerance, however expansion at the sharp corners was found distorted. The accuracy of the DVH calculations depends on the grid size. TPS calculations of all the dosimetric parameters were in good agreement with the measured values, however for asymmetric open and wedged fields, few points were found out of tolerance. Smaller grid size calculation showed better agreement of dose calculation in the build-up region. Independent tests for MU calculation showed a variation within +/-2% (relative to planning system), meanwhile variation of 3.0% was observed when the central axis was blocked. The test results were in agreement with the tolerance specified by IAEA TRS 430. A subset of the commissioning tests has been identified as a baseline data for an ongoing QA program.

  2. Estimation of mean glandular dose for contrast enhanced digital mammography: factors for use with the UK, European and IAEA breast dosimetry protocols

    NASA Astrophysics Data System (ADS)

    Dance, D. R.; Young, K. C.

    2014-05-01

    The UK, European and IAEA protocols for breast dosimetry in mammography use tabulations of conversion factors, which relate measurements of incident air kerma to the mean glandular dose to the breast. To supplement the existing tabulations, a Monte Carlo computer program has been used to calculate conversion factors for the high-energy spectra used for contrast enhanced digital mammography. The calculations were made for the x-ray spectra from a tungsten target (tube voltage range 40-50 kV) filtered by 0.28, 0.30 and 0.32 mm of copper, and from molybdenum and rhodium targets (tube voltage range 40-49 kV), each filtered by 0.30 mm of copper. The g-factors for all of these spectra were plotted for each breast thickness as a function of half value layer (HVL) and were found to lie on smooth curves within 0.3%. These reflect the fact that the characteristic x-rays present in the spectra from molybdenum and rhodium are heavily filtered and all the spectra are essentially Bremsstrahlung. As a consequence, the s-factor previously used in the dosimetry protocols to adjust for different target/filter combinations can be taken as unity for all of the spectra considered. Tables of g-factors and c-factors are provided for breast thicknesses in the range 20-110 mm and HVLs in the range 2.4-3.6 mm of aluminium. The tables of c-factors are given for breast glandularities in the range 0.1%-100% and for typical glandularities for women in the age bands 40-49 and 50-64 attending the UK national breast screening programme.

  3. Impact of bacteriophage Saint3 carriage on the immune evasion capacity and hemolytic potential of Staphylococcus aureus CC398.

    PubMed

    Jung, Philipp; Abdelbary, Mohamed M H; Kraushaar, Britta; Fetsch, Alexandra; Geisel, Jürgen; Herrmann, Mathias; Witte, Wolfgang; Cuny, Christiane; Bischoff, Markus

    2017-02-01

    Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA) isolates of clonal complex 398 (CC398) are frequently found in Europe, and recent studies highlighted the importance of mobile genetic element (MGE) exchange for host adaptation of this lineage. Of note, one of the MGEs commonly found in human S. aureus isolates, the immune evasion cluster (IEC) harboring bacteriophage Saint3, is very rarely found in LA-MRSA CC398 isolates obtained from farm animals, but more frequently found in LA-MRSA CC398 that were retransmitted to humans. Here, we analyzed with a set of S. aureus CC398 isolates harboring/lacking φSaint3 how this MGE affects (i) phagocytosis of CC398 isolates by polymorphonuclear neutrophils (PMNs), and (ii) hemolysis of human and livestock-derived erythrocytes. Isolates lacking φSaint3 were more efficiently phagocytosed by human PMNs in whole blood phagocytosis assays than isolates harboring this bacteriophage, irrespective of their origin. Notably, a similar effect was observed when equine blood was utilized, but not detected with porcine blood. Integration of φSaint3 into LA-MRSA CC398 strains lacking this MGE confirmed these findings, as φSaint3-harboring recipients were again less efficiently ingested by PMNs in equine and human blood than their parental strains. Integration of φSaint3 strongly reduced the hemolytic potential of the culture supernatants against human-derived erythrocytes, and to a smaller extent also against porcine-derived erythrocytes, while φSaint3 integration only slightly affected the hemolytic capacities against equine-derived red blood cells. The significant protective effect of φSaint3 against phagocytosis by equine PMNs suggests that the host specificity of the IEC components might be broader than currently assumed. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Commercial Biocides Induce Transfer of Prophage Φ13 from Human Strains of Staphylococcus aureus to Livestock CC398.

    PubMed

    Tang, Yuanyue; Nielsen, Lene N; Hvitved, Annemette; Haaber, Jakob K; Wirtz, Christiane; Andersen, Paal S; Larsen, Jesper; Wolz, Christiane; Ingmer, Hanne

    2017-01-01

    Human strains of Staphylococcus aureus commonly carry the bacteriophage ΦSa3 that encodes immune evasion factors. Recently, this prophage has been found in livestock-associated, methicillin resistant S. aureus (MRSA) CC398 strains where it may promote human colonization. Here, we have addressed if exposure to biocidal products induces phage transfer, and find that during co-culture, Φ13 from strain 8325, belonging to ΦSa3 group, is induced and transferred from a human strain to LA-MRSA CC398 when exposed to sub-lethal concentrations of commercial biocides containing hydrogen peroxide. Integration of ΦSa3 in LA-MRSA CC398 occurs at multiple positions and the integration site influences the stability of the prophage. We did not observe integration in hlb encoding β-hemolysin that contains the preferred ΦSa3 attachment site in human strains, and we demonstrate that this is due to allelic variation in CC398 strains that disrupts the phage attachment site, but not the expression of β-hemolysin. Our results show that hydrogen peroxide present in biocidal products stimulate transfer of ΦSa3 from human to LA-MRSA CC398 strains and that in these strains prophage stability depends on the integration site. Knowledge of ΦSa3 transfer and stability between human and livestock strains may lead to new intervention measures directed at reducing human infection by LA-MRSA strains.

  5. Repeated administration of the monoamine reuptake inhibitor BTS 74 398 induces ipsilateral circling in the 6-hydroxydopamine lesioned rat without sensitizing motor behaviours.

    PubMed

    Lane, E L; Cheetham, S C; Jenner, P

    2005-01-01

    BTS 74 398 (1-[1-(3,4-dichlorophenyl)cyclobutyl]-2-(3-diaminethylaminopropylthio)ethanone monocitrate) is a monoamine reuptake inhibitor that reverses motor deficits in MPTP-treated (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) common marmosets without provoking established dyskinesia. However, it is not known whether BTS 74 398 primes the basal ganglia for dyskinesia induction. In this study, the ability of BTS 74 398 to sensitize 6-hydroxydopamine (6-OHDA)-lesioned rats for the production of abnormal motor behaviours and the induction of striatal DeltaFosB were determined in comparison with l-3,4-dihydroxyphenylalanine methyl ester (L-dopa). Acute administration of BTS 74 398 induced a dose-dependent ipsilateral circling response in unilaterally 6-OHDA-lesioned rats whereas L-dopa produced dose-dependent contraversive rotation. The ipsilateral circling response to BTS 74 398 did not alter during 21 days of administration. In contrast, L-dopa treatment for 21 days caused a marked increase in rotational response. Repeated administration of both L-dopa and BTS 74 398 increased general motor activity and stereotypic behaviour. In L-dopa-treated rats, orolingual, locomotive, forelimb and axial abnormal movements developed whereas BTS 74 398 produced only locomotion with a side bias but no other abnormal movements. Sensitization of circling responses and the development of abnormal movements in 6-OHDA-lesioned rats have been associated with the potential of dopaminergic drugs to induce dyskinesia. Furthermore, striatal DeltaFosB immunoreactivity, shown to correlate with dyskinesia induction, was increased by L-dopa but was unaffected by repeated BTS 74 398 administration. The lack of such changes following repeated BTS 74 398 treatment suggests that it may be an effective antiparkinsonian therapy that is unlikely to produce involuntary movements.

  6. 10 CFR 75.7 - Notification of IAEA safeguards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Notification of IAEA safeguards. 75.7 Section 75.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.7 Notification of IAEA safeguards. (a) The licensee must inform the NRC...

  7. 10 CFR 75.7 - Notification of IAEA safeguards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Notification of IAEA safeguards. 75.7 Section 75.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT General Provisions § 75.7 Notification of IAEA safeguards. (a) The licensee must inform the NRC...

  8. Commercial Biocides Induce Transfer of Prophage Φ13 from Human Strains of Staphylococcus aureus to Livestock CC398

    PubMed Central

    Tang, Yuanyue; Nielsen, Lene N.; Hvitved, Annemette; Haaber, Jakob K.; Wirtz, Christiane; Andersen, Paal S.; Larsen, Jesper; Wolz, Christiane; Ingmer, Hanne

    2017-01-01

    Human strains of Staphylococcus aureus commonly carry the bacteriophage ΦSa3 that encodes immune evasion factors. Recently, this prophage has been found in livestock-associated, methicillin resistant S. aureus (MRSA) CC398 strains where it may promote human colonization. Here, we have addressed if exposure to biocidal products induces phage transfer, and find that during co-culture, Φ13 from strain 8325, belonging to ΦSa3 group, is induced and transferred from a human strain to LA-MRSA CC398 when exposed to sub-lethal concentrations of commercial biocides containing hydrogen peroxide. Integration of ΦSa3 in LA-MRSA CC398 occurs at multiple positions and the integration site influences the stability of the prophage. We did not observe integration in hlb encoding β-hemolysin that contains the preferred ΦSa3 attachment site in human strains, and we demonstrate that this is due to allelic variation in CC398 strains that disrupts the phage attachment site, but not the expression of β-hemolysin. Our results show that hydrogen peroxide present in biocidal products stimulate transfer of ΦSa3 from human to LA-MRSA CC398 strains and that in these strains prophage stability depends on the integration site. Knowledge of ΦSa3 transfer and stability between human and livestock strains may lead to new intervention measures directed at reducing human infection by LA-MRSA strains. PMID:29270158

  9. Improving the Transparency of IAEA Safeguards Reporting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toomey, Christopher; Hayman, Aaron M.; Wyse, Evan T.

    2011-07-17

    In 2008, the Standing Advisory Group on Safeguards Implementation (SAGSI) indicated that the International Atomic Energy Agency's (IAEA) Safeguards Implementation Report (SIR) has not kept pace with the evolution of safeguards and provided the IAEA with a set of recommendations for improvement. The SIR is the primary mechanism for providing an overview of safeguards implementation in a given year and reporting on the annual safeguards findings and conclusions drawn by the Secretariat. As the IAEA transitions to State-level safeguards approaches, SIR reporting must adapt to reflect these evolutionary changes. This evolved report will better reflect the IAEA's transition to amore » more qualitative and information-driven approach, based upon State-as-a-whole considerations. This paper applies SAGSI's recommendations to the development of multiple models for an evolved SIR and finds that an SIR repurposed as a 'safeguards portal' could significantly enhance information delivery, clarity, and transparency. In addition, this paper finds that the 'portal concept' also appears to have value as a standardized information presentation and analysis platform for use by Country Officers, for continuity of knowledge purposes, and the IAEA Secretariat in the safeguards conclusion process. Accompanying this paper is a fully functional prototype of the 'portal' concept, built using commercial software and IAEA Annual Report data.« less

  10. NS-398, a selective COX-2 inhibitor, inhibits proliferation of IL-1{beta}-stimulated vascular smooth muscle cells by induction of {eta}{omicron}-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Hyoung Chul; Kim, Hee Sun; Lee, Kwang Youn

    2008-11-28

    We investigated whether NS-398, a selective inhibitor of COX-2, induces HO-1 in IL-1{beta}-stimulated vascular smooth muscle cells (VSMC). NS-398 reduced the production of PGE{sub 2} without modulation of expression of COX-2 in IL-1{beta}-stimulated VSMC. NS-398 increased HO-1 mRNA and protein in a dose-dependent manner, but inhibited proliferation of IL-1{beta}-stimulated VSMC. Furthermore, SnPPIX, a HO-1 inhibitor, reversed the effects of NS-398 on PGE{sub 2} production, suggesting that COX-2 activity can be affected by HO-1. Hemin, a HO-1 inducer, also reduced the production of PGE{sub 2} and proliferation of IL-1{beta}-stimulated VSMC. CORM-2, a CO-releasing molecule, but not bilirubin inhibited proliferation of IL-1{beta}-stimulatedmore » VSMC. NS-398 inhibited proliferation of IL-1{beta}-stimulated VSMC in a HbO{sub 2}-sensitive manner. In conclusion, NS-398 inhibits proliferation of IL-1{beta}-stimulated VSMC by HO-1-derived CO. Thus, NS-398 may facilitate the healing process of vessels in vascular inflammatory disorders such as atherosclerosis.« less

  11. Certified reference materials for radionuclides in Bikini Atoll sediment (IAEA-410) and Pacific Ocean sediment (IAEA-412).

    PubMed

    Pham, M K; van Beek, P; Carvalho, F P; Chamizo, E; Degering, D; Engeler, C; Gascó, C; Gurriaran, R; Hanley, O; Harms, A V; Herrmann, J; Hult, M; Ikeuchi, Y; Ilchmann, C; Kanisch, G; Kis-Benedek, G; Kloster, M; Laubenstein, M; Llaurado, M; Mas, J L; Nakano, M; Nielsen, S P; Osvath, I; Povinec, P P; Rieth, U; Schikowski, J; Smedley, P A; Suplinska, M; Sýkora, I; Tarjan, S; Varga, B; Vasileva, E; Zalewska, T; Zhou, W

    2016-03-01

    The preparation and characterization of certified reference materials (CRMs) for radionuclide content in sediments collected offshore of Bikini Atoll (IAEA-410) and in the open northwest Pacific Ocean (IAEA-412) are described and the results of the certification process are presented. The certified radionuclides include: (40)K, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (234)U, (238)U, (239)Pu, (239+240)Pu and (241)Am for IAEA-410 and (40)K, (137)Cs, (210)Pb ((210)Po), (226)Ra, (228)Ra, (228)Th, (232)Th, (235)U, (238)U, (239)Pu, (240)Pu and (239+240)Pu for IAEA-412. The CRMs can be used for quality assurance and quality control purposes in the analysis of radionuclides in sediments, for development and validation of analytical methods and for staff training. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. First detection of livestock-associated meticillin-resistant Staphylococcus aureus CC398 in bulk tank milk in the United Kingdom, January to July 2012

    PubMed Central

    Paterson, G K; Larsen, J; Harrison, E M; Larsen, A R; Morgan, F J; Peacock, S J; Parkhill, J; Zadoks, R N; Holmes, M A

    2013-01-01

    Livestock-associated meticillin-resistant Staphylococcus aureus belonging to clonal complex 398 (LA-MRSA CC398) is an important cause of zoonotic infections in several countries, but there is only a single published report of this lineage from the United Kingdom (UK). Here, we describe the isolation of LA-MRSA CC398 from bulk tank milk from five geographically dispersed farms in the UK. Our findings suggest that LA-MRSA CC398 is established in livestock in the UK. Awareness of the potential occupational risks and surveillance in other food-producing animal species should be promoted. PMID:23241232

  13. A Novel ESAT-6 Secretion System-Secreted Protein EsxX of Community-Associated Staphylococcus aureus Lineage ST398 Contributes to Immune Evasion and Virulence.

    PubMed

    Dai, Yingxin; Wang, Yanan; Liu, Qian; Gao, Qianqian; Lu, Huiying; Meng, Hongwei; Qin, Juanxiu; Hu, Mo; Li, Min

    2017-01-01

    The ESAT-6 secretion system (ESS) has been reported to contribute to the virulence and pathogenicity of several Staphylococcus aureus strains such as USA300 and Newman. However, the role of the ESS in community-associated S. aureus (CA-SA) lineage ST398 in China is not well understood. By comparing the ess locus of ST398 with the published S. aureus sequence in the NCBI database, we found one gene in the ess locus encoding a novel WXG superfamily protein that is highly conserved only in ST398. LC-MS/MS and Western blot analysis revealed that this protein is a novel secreted protein controlled by the ST398 ESS, and we named the protein EsxX. Although EsxX was not under the control of the accessory gene regulator like many other virulence factors and had no influence on several phenotypes of ST398, such as growth, hemolysis, and biofilm formation, it showed important impacts on immune evasion and virulence in ST398. An esxX deletion mutant led to significantly reduced resistance to neutrophil killing and decreased virulence in murine skin and blood infection models, indicating its essential contribution to the evasion of innate host defense and virulence to support the pathogenesis of ST398 infections. The function of this novel secreted protein EsxX might help us better understand the role of the ESS in the virulence and epidemic success of the CA-SA lineage ST398.

  14. IAEA support to medical physics in nuclear medicine.

    PubMed

    Meghzifene, Ahmed; Sgouros, George

    2013-05-01

    Through its programmatic efforts and its publications, the International Atomic Energy Agency (IAEA) has helped define the role and responsibilities of the nuclear medicine physicist in the practice of nuclear medicine. This paper describes the initiatives that the IAEA has undertaken to support medical physics in nuclear medicine. In 1984, the IAEA provided guidance on how to ensure that the equipment used for detecting, imaging, and quantifying radioactivity is functioning properly (Technical Document [TECDOC]-137, "Quality Control of Nuclear Medicine Instruments"). An updated version of IAEA-TECDOC-137 was issued in 1991 as IAEA-TECDOC-602, and this included new chapters on scanner-computer systems and single-photon emission computed tomography systems. Nuclear medicine physics was introduced as a part of a project on radiation imaging and radioactivity measurements in the 2002-2003 IAEA biennium program in Dosimetry and Medical Radiation Physics. Ten years later, IAEA activities in this field have expanded to cover quality assurance (QA) and quality control (QC) of nuclear medicine equipment, education and clinical training, professional recognition of the role of medical physicists in nuclear medicine physics, and finally, the coordination of research and development activities in internal dosimetry. As a result of these activities, the IAEA has received numerous requests to support the development and implementation of QA or QC programs for radioactivity measurements in nuclear medicine in many Member States. During the last 5 years, support was provided to 20 Member States through the IAEA's technical cooperation programme. The IAEA has also supported education and clinical training of medical physicists. This type of support has been essential for the development and expansion of the Medical Physics profession, especially in low- and middle-income countries. The need for basic as well as specialized clinical training in medical physics was identified as a

  15. RECRUITMENT OF U.S. CITIZENS FOR VACANCIES IN IAEA SAFEGUARDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PEPPER,S.E.; DECARO,D.; WILLIAMS,G.

    The International Atomic Energy Agency (IAEA) relies on its member states to assist with recruiting qualified individuals for positions within the IAEA's secretariat. It is important that persons within and outside the US nuclear and safeguards industries become aware of career opportunities available at the IAEA, and informed about important vacancies. The IAEA has established an impressive web page to advertise opportunities for employment. However, additional effort is necessary to ensure that there is sufficient awareness in the US of these opportunities, and assistance for persons interested in taking positions at the IAEA. In 1998, the Subgroup on Safeguards Technicalmore » Support (SSTS) approved a special task under the US Support Program to IAEA Safeguards (USSP) for improving US efforts to identify qualified candidates for vacancies in IAEA's Department of Safeguards. The International Safeguards Project Office (ISPO) developed a plan that includes increased advertising, development of a web page to support US recruitment efforts, feedback from the US Mission in Vienna, and interaction with other recruitment services provided by US professional organizations. The main purpose of this effort is to educate US citizens about opportunities at the IAEA so that qualified candidates can be identified for the IAEA's consideration.« less

  16. 10 CFR 75.12 - Communication of information to IAEA.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Communication of information to IAEA. 75.12 Section 75.12 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.12 Communication of information to IAEA. (a) Except as...

  17. 10 CFR 75.12 - Communication of information to IAEA.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Communication of information to IAEA. 75.12 Section 75.12 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.12 Communication of information to IAEA. (a) Except as...

  18. USSP-IAEA WORKSHOP ON ADVANCED SENSORS FOR SAFEGUARDS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PEPPER,S.; QUEIROLO, A.; ZENDEL, M.

    2007-11-13

    The IAEA Medium Term Strategy (2006-2011) defines a number of specific goals in respect to the IAEA's ability to provide assurances to the international community regarding the peaceful use of nuclear energy through States adherences to their respective non-proliferation treaty commitments. The IAEA has long used and still needs the best possible sensors to detect and measure nuclear material. The Department of Safeguards, recognizing the importance of safeguards-oriented R&D, especially targeting improved detection capabilities for undeclared facilities, materials and activities, initiated a number of activities in early 2005. The initiatives included letters to Member State Support Programs (MSSPs), personal contactsmore » with known technology holders, topical meetings, consultant reviews of safeguards technology, and special workshops to identify new and novel technologies and methodologies. In support of this objective, the United States Support Program to IAEA Safeguards hosted a workshop on ''Advanced Sensors for Safeguards'' in Santa Fe, New Mexico, from April 23-27, 2007. The Organizational Analysis Corporation, a U.S.-based management consulting firm, organized and facilitated the workshop. The workshop's goal was to help the IAEA identify and plan for new sensors for safeguards implementation. The workshop, which was attended by representatives of seven member states and international organizations, included presentations by technology holders and developers on new technologies thought to have relevance to international safeguards, but not yet in use by the IAEA. The presentations were followed by facilitated breakout sessions where the participants considered two scenarios typical of what IAEA inspectors might face in the field. One scenario focused on an enrichment plant; the other scenario focused on a research reactor. The participants brainstormed using the technologies presented by the participants and other technologies known to them to propose

  19. miR398 and miR395 are involved in response to SO2 stress in Arabidopsis thaliana.

    PubMed

    Li, Lihong; Yi, Huilan; Xue, Meizhao; Yi, Min

    2017-11-01

    Sulfur dioxide (SO 2 ) is a common air pollutant that has adverse effects on plants. MicroRNAs (miRNAs) are small noncoding RNA that play critical roles in plant development and stress response. In this study, we found that two miRNAs, miR398 and miR395, were differentially expressed in Arabidopsis shoots under SO 2 stress. The expression of miR398 was down-regulated, and the transcript levels of its target genes, Cu/Zn superoxide dismutases (CSD1 and CSD2), were increased during SO 2 exposure. The activity of superoxide dismutase (SOD), one of the major antioxidant enzymes, was enhanced with the increase in the CSD transcript level, suggesting an important role of miR398 in response to SO 2 -induced oxidative stress. Meanwhile, the expression of miR395 was increased, and the transcript levels of its target genes, ATP sulfurylases (APS3 and APS4) and a low-affinity sulfate transporter (SULTR2;1), were decreased in Arabidopsis shoots, showing that miR395 played important roles in the regulation of sulfate assimilation and translocation during SO 2 exposure. The content of glutathione (GSH), an important sulfur-containing antioxidant, was enhanced with the changes in sulfur metabolism in Arabidopsis shoots under SO 2 stress. These results showed that both miR398 and miR395 were involved in protecting plants from oxidative damage during SO 2 exposure. Many stress-responsive cis-elements were found in the promoter regions of MIR398 and MIR395, suggesting that these miRNAs might respond to various environmental conditions, including SO 2 stress. Overall, our study provides an insight into the regulatory roles of miRNAs in response to SO 2 stress in plants, and highlights the molecular mechanisms of plant adaptation to environmental stress.

  20. 49 CFR 398.6 - Hours of service of drivers; maximum driving time.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Hours of service of drivers; maximum driving time... REGULATIONS TRANSPORTATION OF MIGRANT WORKERS § 398.6 Hours of service of drivers; maximum driving time. No... or operate for more than 10 hours in the aggregate (excluding rest stops and stops for meals) in any...

  1. 49 CFR 398.6 - Hours of service of drivers; maximum driving time.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Hours of service of drivers; maximum driving time... REGULATIONS TRANSPORTATION OF MIGRANT WORKERS § 398.6 Hours of service of drivers; maximum driving time. No... or operate for more than 10 hours in the aggregate (excluding rest stops and stops for meals) in any...

  2. Improving Quality and Access to Radiation Therapy-An IAEA Perspective.

    PubMed

    Abdel-Wahab, May; Zubizarreta, Eduardo; Polo, Alfredo; Meghzifene, Ahmed

    2017-04-01

    The International Atomic Energy Agency (IAEA) has been involved in radiation therapy since soon after its creation in 1957. In response to the demands of Member States, the IAEA׳s activities relating to radiation therapy have focused on supporting low- and middle-income countries to set up radiation therapy facilities, expand the scope of treatments, or gradually transition to new technologies. In addition, the IAEA has been very active in providing internationally harmonized guidelines on clinical, dosimetry, medical physics, and safety aspects of radiation therapy. IAEA clinical research has provided evidence for treatment improvement as well as highly effective resource-sparing interventions. In the process, training of researchers occurs through this program. To provide this support, the IAEA works with its Member States and multiple partners worldwide through several mechanisms. In this article, we review the main activities conducted by the IAEA in support to radiation therapy. IAEA support has been crucial for achieving tangible results in many low- and middle-income countries. However, long-term sustainability of projects can present a challenge, especially when considering health budget constraints and the brain drain of skilled professionals. The need for support remains, with more than 90% of patients in low-income countries lacking access to radiotherapy. Thus, the IAEA is expected to continue its support and strengthen quality radiation therapy treatment of patients with cancer. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Prevalence of colonization by methicillin-resistant Staphylococcus aureus ST398 in pigs and pig farm workers in an area of Catalonia, Spain.

    PubMed

    Reynaga, Esteban; Navarro, Marian; Vilamala, Anna; Roure, Pere; Quintana, Manuel; Garcia-Nuñez, Marian; Figueras, Raül; Torres, Carmen; Lucchetti, Gianni; Sabrià, Miquel

    2016-11-28

    A livestock-associated clonal lineage (ST398) of methicillin-resistant Staphylococcus aureus (MRSA) has been identified causing colonization or infection in farm workers. The aim of the study was to analyze the prevalence of MRSA-ST398 colonization in pigs and in pig farmers in an area with a high pig population (Osona, Barcelona province, Catalonia, Spain). We performed a cross-sectional prevalence study in Osona (Catalonia, Spain), from June 2014 to June 2015. All pig farm workers from 83 farms were studied. Twenty of these farms were randomly selected for the study of both pigs and farmers: 9 fattening and 11 farrow-to-finish farms. All workers over the age of 18 who agreed to participate were included. Samples were analyzed to identify MRSA-ST398 and their spa type. Eighty-one of the 140 pig farm workers analyzed (57.9% (95% IC: 50.0-66.4%)) were MRSA-positive, all of them ST398. The mean number of years worked on farms was 17.5 ± 12.6 (range:1-50), without significant differences between positive and negative MRSA results (p = 0.763). Over 75% of MRSA-ST398 carriers worked on farms with more than 1250 pigs (p < 0.001). At least one worker tested positive for MRSA-ST398 on all 20 selected pig farms. Ninety-two (46.0% (95% IC: 39.0-53.0%)) of the nasal swabs from 200 pigs from these 20 farms were MRSA-positive, with 50.5% of sows and 41.4% of fattening pigs (p = 0.198) giving MRSA-positive results. All the isolates were tetracycline-resistant, and were identified as MRSA-ST398. The spa type identified most frequently was t011 (62%). Similar spa types and phenotypes of antibiotic resistance were identified in pigs and farmers of 19/20 tested farms. The prevalence of MRSA-ST398 among pig farm workers and pigs on farms in the studied region is very high, and the size of the farm seems to correlate with the frequency of colonization of farmers. The similar spa-types and phenotypes of resistance detected in pigs and workers in most of the farms

  4. 75 FR 26701 - Telecommunications Relay Services and Speech-to-Speech Services for Individuals With Hearing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-12

    ... Services (CTS), Internet Protocol (IP) CTS, IP Relay, and Video Relay Services (VRS), for the 2010-2011... comment on NECA's proposed compensation rates for TRS, STS, CTS, IP CTS, IP Relay, and VRS, for the 2010... interstate traditional TRS; $3.1566 for STS; $1.6951 for CTS and IP CTS; $1.2985 for IP Relay. Based on these...

  5. The monoamine reuptake inhibitor BTS 74 398 fails to evoke established dyskinesia but does not synergise with levodopa in MPTP-treated primates.

    PubMed

    Hansard, Matthew J; Smith, Lance A; Jackson, Michael J; Cheetham, Sharon C; Jenner, Peter

    2004-01-01

    Long-term treatment of Parkinson's disease (PD) with levodopa (L-dopa) induces dyskinesia that, once established, is provoked by each dose of L-dopa or a dopamine (DA) agonist. In contrast, monoamine reuptake inhibitors may reverse motor deficits in 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-treated primates without provoking established involuntary movements. We now examine whether the potent monoamine reuptake blocker BTS 74 398 induces established dyskinesia in MPTP-treated common marmosets primed previously with L-dopa and whether co-administration of BTS 74 398 with L-dopa potentiates motor behaviour and dyskinesia induced by acute L-dopa treatment. Administration of BTS 74 398 (2.5, 5.0, or 10.0 mg/kg, p.o.) in MPTP-treated common marmosets increased locomotor activity and reduced motor disability in a dose-related manner but did not provoke involuntary movements. BTS 74 398 (2.5, 5.0, or 10.0 mg/kg p.o.) co-administered with a threshold dose of L-dopa (2.5 mg/kg p.o.) did not evoke a motor response or induce dyskinesia. Similarly, concomitant administration of BTS 74 398 (5.0 mg/kg p.o.) with a submaximal L-dopa dose (12.5 mg/kg p.o.) did not potentiate the motor response produced by L-dopa alone and there was no alteration in the dyskinesia provoked by L-dopa challenge. BTS 74 398 reverses motor abnormalities in MPTP-treated marmosets without evoking established dyskinesia but no additive improvement occurs when administered in combination with L-dopa. The lack of synergy with L-dopa may suggest different sites of drug action. Copyright 2003 Movement Disorder Society

  6. IAEA Sampling Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, William H.

    2017-09-15

    The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.

  7. Methicillin resistant Staphylococcus aureus ST398 in veal calf farming: human MRSA carriage related with animal antimicrobial usage and farm hygiene.

    PubMed

    Graveland, Haitske; Wagenaar, Jaap A; Heesterbeek, Hans; Mevius, Dik; van Duijkeren, Engeline; Heederik, Dick

    2010-06-08

    Recently a specific MRSA sequence type, ST398, emerged in food production animals and farmers. Risk factors for carrying MRSA ST398 in both animals and humans have not been fully evaluated. In this cross-sectional study, we investigated factors associated with MRSA colonization in veal calves and humans working and living on these farms. A sample of 102 veal calf farms were randomly selected and visited from March 2007-February 2008. Participating farmers were asked to fill in a questionnaire (n = 390) to identify potential risk factors. A nasal swab was taken from each participant. Furthermore, nasal swabs were taken from calves (n = 2151). Swabs were analysed for MRSA by selective enrichment and suspected colonies were confirmed as MRSA by using slide coagulase test and PCR for presence of the mecA-gene. Spa types were identified and a random selection of each spa type was tested with ST398 specific PCR. The Sequence Type of non ST398 strains was determined. Data were analyzed using logistic regression analysis. Human MRSA carriage was strongly associated with intensity of animal contact and with the number of MRSA positive animals on the farm. Calves were more often carrier when treated with antibiotics, while farm hygiene was associated with a lower prevalence of MRSA. This is the first study showing direct associations between animal and human carriage of ST398. The direct associations between animal and human MRSA carriage and the association between MRSA and antimicrobial use in calves implicate prudent use of antibiotics in farm animals.

  8. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.

    PubMed

    Sánchez-Doblado, F; Andreo, P; Capote, R; Leal, A; Perucha, M; Arráns, R; Núñez, L; Mainegra, E; Lagares, J I; Carrasco, E

    2003-07-21

    Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s

  9. Frequent isolation of methicillin resistant Staphylococcus aureus (MRSA) ST398 among healthy pigs in Portugal.

    PubMed

    Conceição, Teresa; de Lencastre, Hermínia; Aires-de-Sousa, Marta

    2017-01-01

    Although livestock-associated ST398 methicillin-resistant Staphylococcus aureus (MRSA) has been widely reported in different geographic regions, MRSA carriage studies among healthy pigs in Portugal are very limited. In total, 101 swine nasal samples from two Portuguese farms were screened for MRSA. In addition five swine workers (including one veterinary and one engineer) and four household members were nasally screened. The isolates were characterized by spa typing, SCCmec typing and MLST. All isolates were tested for antimicrobial susceptibility, presence of mecA and mecC genes, and virulence determinants. MRSA prevalence in swine was 99% (100/101), 80% (4/5) in swine workers and 25% (1/4) in household members. All isolates belonged to ST398 distributed over two spa types-t011 (57%) and t108 (42%). SCCmec type V was present in most of the isolates (n = 95; 82%) while 21 isolates amplified the mecA gene only and were classified as nontypeable. The majority of the isolates were resistant to tetracycline (100%), clindamycin (97%), erythromycin (96%), chloramphenicol (84%) and gentamycin (69%). Notably, 12% showed resistance to quinupristin-dalfopristin (MICs 3-8 μg/mL). Beta-hemolysin (81%) and gamma-hemolysin (74%) were the unique virulence determinants detected. None of the isolates harboured PVL or mecC gene. This study showed a massive occurrence of ST398-MRSA in two independent swine farms, highlighting its establishment among healthy pigs in Portugal.

  10. Abstractness and emotionality values for 398 English words.

    PubMed

    Guido, Gianluigi; Provenzano, Maria Rosaria

    2004-06-01

    This study is aimed to replicate Vikis-Freibergs' classic study (1976) on the values of vividness for French words. Vividness resulted from the concreteness and the emotionality values of words, here defined, respectively, as referring to something that can be experienced through senses and that can arouse pleasant or unpleasant emotions. 398 English words were rated on two different scales, Abstractness and Emotionality, by a group of English native speakers and also by a group of Italian subjects who used English as a second language. Results show a low correlation between the concreteness and emotionality ratings in line with Vikis-Freibergs' previous study of French words (1976). A negative correlation between Abstractness and Emotionality was observed for British data but a slightly positive correlation for the Italian data.

  11. The Emergence and Spread of Multiple Livestock-Associated Clonal Complex 398 Methicillin-Resistant and Methicillin-Susceptible Staphylococcus aureus Strains among Animals and Humans in the Republic of Ireland, 2010–2014

    PubMed Central

    Brennan, Gráinne I.; Abbott, Yvonne; Burns, Aisling; Leonard, Finola; McManus, Brenda A.; O’Connell, Brian; Coleman, David C.; Shore, Anna C.

    2016-01-01

    Clonal complex (CC) 398 methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible S. aureus (MSSA) are associated with carriage and infection among animals and humans but only a single case of CC398 MRSA has been reported in the Republic of Ireland (ROI). The present study investigated the molecular epidemiology of CC398 MRSA (n = 22) and MSSA (n = 10) from animals and humans in the ROI from 2010–2014. Isolates underwent antimicrobial susceptibility testing, spa typing, DNA microarray profiling and PCR for CC398-associated resistance genes. All MRSA underwent SCCmec IV or V subtyping. Four distinct CC398-MRSA incidents were identified from (i) a man in a nursing home (spa type t011-SCCmec IVa, immune evasion complex (IEC) negative), (ii) a horse and veterinarian who had recently travelled to Belgium (t011-IVa, IEC positive), (iii) pigs (n = 9) and farm workers (n = 9) on two farms, one which had been restocked with German gilts and the other which was a finisher farm (t034-VT, IEC negative, 3/9 pigs; t011- VT, IEC negative, 6/9 pigs & 9/9 farm workers), and (iv) a child who had worked on a pig farm in the UK (t034-VT, IEC negative). Isolates also carried different combinations of multiple resistance genes including erm(A), erm(B), tet(K), tet(M) & tet(L), fexA, spc, dfrG, dfrK aacA-aphD and aadD further highlighting the presence of multiple CC398-MRSA strains. CC398 MSSA were recovered from pigs (n = 8) and humans (n = 2). CC398 MSSA transmission was identified among pigs but zoonotic transmission was not detected with animal and human isolates exhibiting clade-specific traits. This study highlights the importation and zoonotic spread of CC398 MRSA in the ROI and the spread of CC398 MSSA among pigs. Increased surveillance is warranted to prevent further CC398 MRSA importation and spread in a country that was considered CC398 MRSA free. PMID:26886749

  12. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dalaryd, Mårten, E-mail: Marten.Dalaryd@med.lu.se; Knöös, Tommy; Ceberg, Crister

    {sup -}/ρ){sub air}{sup water} for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR{sub 20,10}. Using the relationship in IAEA, TRS-398 resulted in a root mean square deviation (RMSD) of 0.0028 with a maximum deviation of 0.0043 (0.39%) from Monte Carlo calculated values. For all beams in this study, the RMSD between the proposed model and the Monte Carlo calculated values was 0.0006 with a maximum deviation of 0.0013 (0.1%). Using an earlier proposed relationship [Xiong and Rogers, Med. Phys. 35, 2104–2109 (2008)] between %dd(10){sub x} and (L{sup -}/ρ){sub air}{sup water} gave a RMSD of 0.0018 with a maximum deviation of 0.0029 (0.26%) for all beams in this study (compared to RMSD 0.0015 and a maximum deviation of 0.0048 (0.47%) for the relationship used in AAPM TG-51 published by Almond et al. [Med. Phys. 26, 1847–1870 (1999)]). Conclusions: Using TPR{sub 20,10} as a beam-quality specifier, for the flattening filter free beams used in this study, gave a maximum difference of 0.39% between (L{sup -}/ρ){sub air}{sup water} predicted using IAEA TRS-398 and Monte Carlo calculations. An additional parameter for determining (L{sup -}/ρ){sub air}{sup water} has been presented. This parameter is easy to measure; it requires only an additional dose measurement at 5 cm depth with SSD 95 cm, and provides information for accurate determination of the (L{sup -}/ρ){sub air}{sup water} ratio for beams both with and without a flattening filter at the investigated energies.« less

  13. Unusual presence of the immune evasion gene cluster in livestock-associated MRSA of lineage CC398 causing peridural and psoas abscesses in a poultry farmer.

    PubMed

    Pérez-Moreno, Mar Olga; Centelles-Serrano, María José; Nogales-López, Julio; Domenech-Spanedda, Marie France; Lozano, Carmen; Torres, Carmen

    2017-12-01

    To characterize a methicillin-resistant Staphylococcus aureus (MRSA) isolate responsible for an aggressive infection (peridural and psoas abscess secondary to haematogenous septic arthritis) in a poultry farmer. Molecular characterization was performed, including spa- and multilocus sequence typing of the isolate, assessment of its resistance phenotype and detection of tetracycline resistance and of virulence and immune evasion cluster (IEC) genes were performed. The MRSA isolate was tetracycline- and fluorquinolone-resistant, and was ascribed to CC398, spa-t1451. The isolate harboured tet(M) (distinctive of livestock-associated (LA) MRSA-CC398 clade) and IEC-type B system (characteristic of the methicillin-susceptible human lineage, but typically absent in LA-MRSA-CC398 strains), and lacked toxin-coding genes lukF/lukS-PV, tsst-1, eta and etb. IEC re-acquisition by LA-MRSA-CC398-LA strains is an unusual finding, but could constitute an emerging public health problem. It would represent an evolutionary step towards LA-MRSA-CC398's adaptation to human hosts, and might enhance its invasiveness and ability to be transmitted to humans. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Cloning and occurrence of czrC, a gene conferring cadmium and zinc resistance in methicillin-resistant Staphylococcus aureus CC398 isolates.

    PubMed

    Cavaco, L M; Hasman, H; Stegger, M; Andersen, P S; Skov, R; Fluit, A C; Ito, T; Aarestrup, F M

    2010-09-01

    We recently reported a phenotypic association between reduced susceptibility to zinc and methicillin resistance in Staphylococcus aureus CC398 isolates from Danish swine (F. M. Aarestrup, L. M. Cavaco, and H. Hasman, Vet. Microbiol. 142:455-457, 2009). The aim of this study was to identify the genetic determinant causing zinc resistance in CC398 and examine its prevalence in isolates of animal and human origin. Based on the sequence of the staphylococcal cassette chromosome mec (SCCmec) element from methicillin-resistant S. aureus (MRSA) CC398 strain SO385, a putative metal resistance gene was identified in strain 171 and cloned in S. aureus RN4220. Furthermore, 81 MRSA and 48 methicillin-susceptible S. aureus (MSSA) strains, isolated from pigs (31 and 28) and from humans (50 and 20) in Denmark, were tested for susceptibility to zinc chloride and for the presence of a putative resistance determinant, czrC, by PCR. The cloning of czrC confirmed that the zinc chloride and cadmium acetate MICs for isogenic constructs carrying this gene were increased compared to those for S. aureus RN4220. No difference in susceptibility to sodium arsenate, copper sulfate, or silver nitrate was observed. Seventy-four percent (n = 23) of the animal isolates and 48% (n = 24) of the human MRSA isolates of CC398 were resistant to zinc chloride and positive for czrC. All 48 MSSA strains from both human and pig origins were found to be susceptible to zinc chloride and negative for czrC. Our findings showed that czrC is encoding zinc and cadmium resistance in CC398 MRSA isolates, and that it is widespread both in humans and animals. Thus, resistance to heavy metals such as zinc and cadmium may play a role in the coselection of methicillin resistance in S. aureus.

  15. Extended Kd distributions for freshwater environment.

    PubMed

    Boyer, Patrick; Wells, Claire; Howard, Brenda

    2018-06-18

    Many of the freshwater K d values required for quantifying radionuclide transfer in the environment (e.g. ERICA Tool, Symbiose modelling platform) are either poorly reported in the literature or not available. To partially address this deficiency, Working Group 4 of the IAEA program MODARIA (2012-2015) has completed an update of the freshwater K d databases and K d distributions given in TRS 472 (IAEA, 2010). Over 2300 new values for 27 new elements were added to the dataset and 270 new K d values were added for the 25 elements already included in TRS 472 (IAEA, 2010). For 49 chemical elements, the K d values have been classified according to three solid-liquid exchange conditions (adsorption, desorption and field) as was previously carried out in TRS 472. Additionally, the K d values were classified into two environmental components (suspended and deposited sediments). Each combination (radionuclide x component x condition) was associated with log-normal distributions when there was at least ten K d values in the dataset and to a geometric mean when there was less than ten values. The enhanced K d dataset shows that K d values for suspended sediments are significantly higher than for deposited sediments and that the variability of K d distributions are higher for deposited than for suspended sediments. For suspended sediments in field conditions, the variability of K d distributions can be significantly reduced as a function of the suspended load that explains more than 50% of the variability of the K d datasets of U, Si, Mo, Pb, S, Se, Cd, Ca, B, K, Ra and Po. The distinction between adsorption and desorption conditions is justified for deterministic calculations because the geometric means are systematically greater in desorption conditions. Conversely, this distinction is less relevant for probabilistic calculations due to systematic overlapping between the K d distributions of these two conditions. Copyright © 2018. Published by Elsevier Ltd.

  16. Development of characterization protocol for mixed liquid radioactive waste classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zakaria, Norasalwa, E-mail: norasalwa@nuclearmalaysia.gov.my; Wafa, Syed Asraf; Wo, Yii Mei

    2015-04-29

    Mixed liquid organic waste generated from health-care and research activities containing tritium, carbon-14, and other radionuclides posed specific challenges in its management. Often, these wastes become legacy waste in many nuclear facilities and being considered as ‘problematic’ waste. One of the most important recommendations made by IAEA is to perform multistage processes aiming at declassification of the waste. At this moment, approximately 3000 bottles of mixed liquid waste, with estimated volume of 6000 litres are currently stored at the National Radioactive Waste Management Centre, Malaysia and some have been stored for more than 25 years. The aim of this studymore » is to develop a characterization protocol towards reclassification of these wastes. The characterization protocol entails waste identification, waste screening and segregation, and analytical radionuclides profiling using various analytical procedures including gross alpha/ gross beta, gamma spectrometry, and LSC method. The results obtained from the characterization protocol are used to establish criteria for speedy classification of the waste.« less

  17. International Scavenging for First Responder Guidance and Tools: IAEA Products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, W.; Berthelot, L.; Bachner, K.

    In fiscal years (FY) 2016 and 2017, with support from the U.S. Department of Homeland Security (DHS), Brookhaven National Laboratory (BNL) examined the International Atomic Energy Agency (IAEA) radiological emergency response and preparedness products (guidance and tools) to determine which of these products could be useful to U.S. first responders. The IAEA Incident and Emergency Centre (IEC), which is responsible for emergency preparedness and response, offers a range of tools and guidance documents for responders in recognizing, responding to, and recovering from radiation emergencies and incidents. In order to implement this project, BNL obtained all potentially relevant tools and productsmore » produced by the IAEA IEC and analyzed these materials to determine their relevance to first responders in the U.S. Subsequently, BNL organized and hosted a workshop at DHS National Urban Security Technology Laboratory (NUSTL) for U.S. first responders to examine and evaluate IAEA products to consider their applicability to the United States. This report documents and describes the First Responder Product Evaluation Workshop, and provides recommendations on potential steps the U.S. federal government could take to make IAEA guidance and tools useful to U.S. responders.« less

  18. 78 FR 76097 - Request for Comment on Petition Filed by Sprint Corporation for Reconsideration of Certain Rules...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... for Internet Protocol Captioned Telephone Service AGENCY: Federal Communications Commission. ACTION... Internet Protocol Captioned Telephone Service (IP CTS) in the IP CTS Reform Order. The Commission seeks... from the Interstate Telecommunications Relay Service Fund (TRS Fund) for minutes of use generated by...

  19. U.S. Additional Protocol Outreach Program-Tabletop Exercises to Implement the AP.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langner, D. C.; Thomas, K. E.; Smith, M. K.

    2005-01-01

    The Office of International Regimes and Agreement (NA-243) is the lead office in the Department of Energy (DOE) to assist DOE and National Nuclear Security Administration (NNSA) sites in the preparation of providing declarations on relevant civilian, nuclear fuel cycle-related research and development activities to the International Atomic Energy Agency (IAEA). This is in accordance to the implementation of the ''Protocol Additional to the AGreement between the United STates and the International Atomic Energy Agency for the Applications of Safeguards in the United States. In preparation for entry-into-force, NA-243 conducted two tabletop exercises under the Additional Protocol Outreach Program. Themore » first one, held in May 2004 at Los Alamos National Laboratory, focused on the factors important to protect national security assets and intellectual property. The other, held in August 2004 at the Idaho National Laboratory explored the level of detail or granularity for reporting declarable activities. Both tabletops invited participants from the national laboratories and DOE/NNSA organizations. Discussions were based around the process to identify potential declarable activities relating to the nuclear fuel cycle-related R and D projects from the Advanced Fuel Cycle Initiative program. The two tabletop exercises provided recommendations and conclusions that would be helpful to other DOE/NNSA locations for preparing for and reporting relevant and concise information to the IAEA under the Additional Protocol. This paper provides details on the events, discussions, observations, and lessons learned from both the LANL and INL tabletop exercises.« less

  20. Ambient temperature enhanced freezing tolerance of Chrysanthemum dichrum CdICE1 Arabidopsis via miR398.

    PubMed

    Chen, Yu; Jiang, Jiafu; Song, Aiping; Chen, Sumei; Shan, Hong; Luo, Huolin; Gu, Chunsun; Sun, Jing; Zhu, Lu; Fang, Weimin; Chen, Fadi

    2013-12-19

    ICE (Inducer of CBF Expression) family genes play an important role in the regulation of cold tolerance pathways. In an earlier study, we isolated the gene CdICE1 from Chrysanthemum dichrum and demonstrated that freezing tolerance was enhanced by CdICE1 overexpression. Therefore, we sought to determine the mechanism by which ICE1 family genes participate in freezing tolerance. Using EMSA (Electrophoretic Mobility Shift Assay) and yeast one-hybrid assays, we confirmed that CdICE1 binds specifically to the MYC element in the CdDREBa promoter and activates transcription. In addition, overexpression of CdICE1 enhanced Arabidopsis freezing tolerance after transition from 23°C to 4°C or 16°C. We found that after acclimation to 4°C, CdICE1, like Arabidopsis AtICE1, promoted expression of CBFs (CRT/DRE Binding Factor) and their genes downstream involved in freezing tolerance, including COR15a (Cold-Regulated 15a), COR6.6, and RD29a (Responsive to Dessication 29a). Interestingly, we observed that CdICE1-overexpressing plants experienced significant reduction in miR398. In addition, its target genes CSD1 (Copper/zinc Superoxide Dismutase 1) and CSD2 showed inducible expression under acclimation at 16°C, indicating that the miR398-CSD pathway was involved in the induction of freezing tolerance. Our data indicate that CdICE1-mediated freezing tolerance occurs via different pathways, involving either CBF or miR398, under acclimation at two different temperatures.

  1. Ambient temperature enhanced freezing tolerance of Chrysanthemum dichrum CdICE1 Arabidopsis via miR398

    PubMed Central

    2013-01-01

    Background ICE (Inducer of CBF Expression) family genes play an important role in the regulation of cold tolerance pathways. In an earlier study, we isolated the gene CdICE1 from Chrysanthemum dichrum and demonstrated that freezing tolerance was enhanced by CdICE1 overexpression. Therefore, we sought to determine the mechanism by which ICE1 family genes participate in freezing tolerance. Results Using EMSA (Electrophoretic Mobility Shift Assay) and yeast one-hybrid assays, we confirmed that CdICE1 binds specifically to the MYC element in the CdDREBa promoter and activates transcription. In addition, overexpression of CdICE1 enhanced Arabidopsis freezing tolerance after transition from 23°C to 4°C or 16°C. We found that after acclimation to 4°C, CdICE1, like Arabidopsis AtICE1, promoted expression of CBFs (CRT/DRE Binding Factor) and their genes downstream involved in freezing tolerance, including COR15a (Cold-Regulated 15a), COR6.6, and RD29a (Responsive to Dessication 29a). Interestingly, we observed that CdICE1-overexpressing plants experienced significant reduction in miR398. In addition, its target genes CSD1 (Copper/zinc Superoxide Dismutase 1) and CSD2 showed inducible expression under acclimation at 16°C, indicating that the miR398-CSD pathway was involved in the induction of freezing tolerance. Conclusions Our data indicate that CdICE1-mediated freezing tolerance occurs via different pathways, involving either CBF or miR398, under acclimation at two different temperatures. PMID:24350981

  2. Introduction of plasmid DNA into an ST398 livestock-associated methicillin-resistant Staphylococcus aureus strain

    USDA-ARS?s Scientific Manuscript database

    MRS926 is a livestock-associated methicillin-resistant Staphylococcus aureus (MRSA) strain of sequence type (ST) 398. In order to facilitate in vitro and in vivo studies of this strain, we sought to tag it with a fluorescent marker. We cloned a codon-optimized gene for TurboGFP into a shuttle vector...

  3. The clinical impact of livestock-associated methicillin-resistant Staphylococcus aureus of the clonal complex 398 for humans.

    PubMed

    Becker, Karsten; Ballhausen, Britta; Kahl, Barbara C; Köck, Robin

    2017-02-01

    In the past decade, livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA) strains in particular of the clonal complex (CC) 398 have emerged in many parts of the world especially in areas with a high density of pig farming. In those regions, farmworkers and other individuals with professional contact to livestock are very frequently colonized with LA-MRSA. These persons are the presumably source for LA-MRSA transmission to household members and other parts of the human population. Altogether, colonization and/or infection of these individuals lead to the introduction of LA-MRSA into hospitals and other healthcare facilities. Since LA-MRSA CC398 have been found to be specifically adapted to their animal hosts in terms of the equipment with virulence factors, their pathogenicity to human patients is a matter of debate with first reports about clinical cases. Meanwhile, case reports, case series and few studies have demonstrated the capability of LA-MRSA to cause all types of infections attributed to S. aureus in general including fatal courses. Human infections observed comprise e.g. bacteremia, pneumonia, osteomyelitis, endocarditis and many manifestations of skin and soft tissue infections. However, inpatients affected by MRSA CC398 generally show different demographic (e.g. younger, shorter length of hospital stay) and clinical characteristics (e.g. less severe complications) which may explain or at least contribute to a lower disease burden of LA-MRSA compared to other MRSA clonal lineages. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Efficacy of BGJ398, a Fibroblast Growth Factor Receptor 1-3 Inhibitor, in Patients with Previously Treated Advanced Urothelial Carcinoma with FGFR3 Alterations.

    PubMed

    Pal, Sumanta K; Rosenberg, Jonathan E; Hoffman-Censits, Jean H; Berger, Raanan; Quinn, David I; Galsky, Matthew D; Wolf, Juergen; Dittrich, Christian; Keam, Bhumsuk; Delord, Jean-Pierre; Schellens, Jan H M; Gravis, Gwenaelle; Medioni, Jacques; Maroto, Pablo; Sriuranpong, Virote; Charoentum, Chaiyut; Burris, Howard A; Grünwald, Viktor; Petrylak, Daniel; Vaishampayan, Ulka; Gez, Eliahu; De Giorgi, Ugo; Lee, Jae-Lyun; Voortman, Jens; Gupta, Sumati; Sharma, Sunil; Mortazavi, Amir; Vaughn, David J; Isaacs, Randi; Parker, Katie; Chen, Xueying; Yu, Kun; Porter, Dale; Graus Porta, Diana; Bajorin, Dean F

    2018-05-30

    BGJ398, a potent and selective pan-FGFR antagonist, was prospectively evaluated in patients with metastatic urothelial carcinoma bearing a diverse array of FGFR3 alterations. Patients ( N = 67) who were unable to receive platinum chemotherapy were enrolled. The majority (70.1%) had received two or more prior antineoplastic therapies. BGJ398 was administered orally at 125 mg/day on a 3 weeks on, 1 week off schedule until unacceptable toxicity or progression. The primary endpoint was the response rate. Among 67 patients treated, an overall response rate of 25.4% was observed and an additional 38.8% of patients had disease stabilization, translating to a disease control rate of 64.2%. The most common treatment-emergent toxicities were hyperphosphatemia, elevated creatinine, fatigue, constipation, and decreased appetite. Further examination of BGJ398 in this disease setting is warranted. SIGNIFICANCE: BJG398 is active in patients with alterations in FGFR3 , resulting in both reductions in tumor volume and stabilization of disease. Our data highlight putative mechanisms of resistance to the agent, which may be useful in following disease status. Cancer Discov; 8(7); 1-10. ©2018 AACR. ©2018 American Association for Cancer Research.

  5. RELAP5 posttest calculation of IAEA-SPE-4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petelin, S.; Mavko, B.; Parzer, I.

    The International Atomic Energy Agency`s Fourth Standard Problem Exercise (IAEA-SPE-4) was performed at the PMK-2 facility. The PMK-2 facility is designed to study processes following small- and medium-size breaks in the primary system and natural circulation in VVER-440 plants. The IAEA-SPE-4 experiment represents a cold-leg side small break, similar to the IAEA-SPE-2, with the exception of the high-pressure safety injection being unavailable, and the secondary side bleed and feed initiation. The break valve was located at the dead end of a vertical downcomer, which in fact simulates a break in the reactor vessel itself, and should be unlikely to happenmore » in a real nuclear power plant (NPP). Three different RELAP5 code versions were used for the transient simulation in order to assess the calculations with test results.« less

  6. 10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...

  7. 10 CFR 150.17a - Compliance with requirements of US/IAEA Safeguards Agreement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Compliance with requirements of US/IAEA Safeguards... Authority in Agreement States § 150.17a Compliance with requirements of US/IAEA Safeguards Agreement. (a... shall take other action as may be necessary to implement the US/IAEA Safeguards Agreement, as described...

  8. Complete genome sequence of livestock associated methicillin resistant Staphylococcus aureus ST398 isolated from swine in USA

    USDA-ARS?s Scientific Manuscript database

    Methicillin resistant Staphylococcus aureus colonizes and causes disease in many animal species. Livestock associated-MRSA isolates are represented by isolates of the sequence type 398. These isolates are considered to be livestock adapted. This report provides the complete genome of one swine assoc...

  9. 76 FR 18490 - Contributions to the Telecommunications Relay Service Fund

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-04

    ... voice over Internet Protocol (VoIP) service provider and each provider of non- interconnected VoIP... directs that within one year after the date of enactment of the CVAA, such VoIP providers shall... Fund (TRS Fund) by non-interconnected Voice over Internet Protocol (VoIP) service providers with...

  10. Refinement of Molecular Diagnostic Protocol of Auditory Neuropathy Spectrum Disorder

    PubMed Central

    Chang, Mun Young; Kim, Ah Reum; Kim, Nayoung K.D.; Lee, Chung; Park, Woong-Yang; Choi, Byung Yoon

    2015-01-01

    Abstract Auditory neuropathy spectrum disorder (ANSD) is a sensorineural hearing disorder caused by dysfunction of auditory neural conduction. ANSD has a heterogeneous etiology, including genetic factors; the response to cochlear implantation significantly varies depending on the etiology. The results of timely cochlear implantation for OTOF-related ANSD (DFNB9) have been reported to be good. Therefore, identifying the causative gene of ANSD, especially OTOF, is an important issue to rehabilitate these patients. Six sporadic ANSD subjects without anatomical abnormality of the cochlear nerve, including the 4 subjects that were previously reported to be without detectable OTOF mutation, were included. We performed targeted resequencing (TRS) of known deafness genes and multiphasic bioinformatics analyses of the data that ensured detection of capture failure and structural variations. Exclusion of SNP was also double checked. The TRS data previously obtained from 2 subjects were reanalyzed. Through this study, we detected 2 mutant alleles of OTOF from 5 (83.3%) of 6 ANSD subjects. All of the 5 subjects carried at least 1 mutant allele carrying p.R1939Q. This variant was categorized as a simple SNP (rs201326023) in the database and it resided in the exon with frequent capture failures, which previously led to exclusion of this variant from eligible candidacy mistakenly. In addition, we detected a structural variation within OTOF from a previously undiagnosed ANSD subject, which was the second structural variation reported in DFNB9 subjects to date. We identify a strong etiologic homogeneity of prelingual ANSD in case of the anatomically normal cochlear nerve in Koreans and now report DFNB9 as the single overwhelming cause. Multiphasic analysis of TRS data ensuring detection of capture failure and structural variations would be expected to reveal DFNB9 from a substantial portion of previously undiagnosed ANSD subjects in Koreans. Based on our results, we propose a novel

  11. Four Years of Practical Arrangements between IAEA and Moscow SIA 'Radon': Preliminary Results - 13061

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batyukhnova, O.G.; Karlina, O.K.; Neveikin, P.P.

    The International Education Training Centre (IETC) at Moscow State Unitary Enterprise Scientific and Industrial Association 'Radon' (SIA 'Radon'), in co-operation with the International Atomic Energy Agency (IAEA), has developed expertise and provided training to waste management personnel for the last 15 years. Since 1997, the educational system of the enterprise with the support of the IAEA has acquired an international character: more than 470 experts from 35 countries- IAEA Member States completed the professional development. Training is conducted at various thematic courses or fellowships for individual programs and seminars on IAEA technical projects. In June 2008 a direct agreement (Practicalmore » Arrangements) was signed between SIA 'Radon' and the IAEA on cooperation in the field of development of new technologies, expert's advice to IAEA Member States, and, in particular, the training of personnel in the field of radioactive waste management (RWM), which opens up new perspectives for fruitful cooperation of industry professionals. The paper summarizes the current experience of the SIA 'Radon' in the organization and implementation of the IAEA sponsored training and others events and outlines some of strategic educational elements, which IETC will continue to pursue in the coming years. (authors)« less

  12. Strengthening radiopharmacy practice in IAEA Member States.

    PubMed

    Duatti, Adriano; Bhonsle, Uday

    2013-05-01

    Radiopharmaceuticals are essential components of nuclear medicine procedures. Without radiopharmaceuticals nuclear medicine procedures cannot be performed. Therefore it could be said that 'No radiopharmaceutical-no nuclear medicine.' A good radiopharmacy practice supports nuclear medicine activities by producing radiopharmaceuticals that are safe and are of the required quality in a consistent way. As with any medicinal product, radiopharmaceuticals are required to be produced under carefully controlled conditions and are tested for their quality, prior to the administration to patients, using validated standard operating procedures. These procedures are based on the principles of Good Manufacturing Practice (GMP). The GMP principles are based on scientific knowledge and applicable regulatory requirements and guidance related to radiopharmaceutical productions and use. The International Atomic Energy Agency (IAEA) is committed to promote, in the Member States (MS), a rational and practical approach for the implementation of GMP for compounding or manufacturing of diagnostic or therapeutic radiopharmaceuticals. To pursue this goal the IAEA has developed various mechanisms and collaborations with individual experts in the field and with relevant national and international institutions or organizations. IAEA's activities in promoting radiopharmaceutical science include commissioning expert advice in the form of publications on radiopharmaceutical production, quality control and usage, producing technical guidance on production and regulatory aspects related to new radiopharmaceuticals, creating guidance documentation for self or internal audits of radiopharmaceutical production facilities, producing guidance on implementation of Quality Management System and GMP in radiopharmacy, assisting in creation of specific radiopharmaceutical monographs for the International Pharmacopoeia, and developing radiopharmacy-related human resource capabilities in MS through individual

  13. Fault displacement hazard assessment for nuclear installations based on IAEA safety standards

    NASA Astrophysics Data System (ADS)

    Fukushima, Y.

    2016-12-01

    In the IAEA Safety NS-R-3, surface fault displacement hazard assessment (FDHA) is required for the siting of nuclear installations. If any capable faults exist in the candidate site, IAEA recommends the consideration of alternative sites. However, due to the progress in palaeoseismological investigations, capable faults may be found in existing site. In such a case, IAEA recommends to evaluate the safety using probabilistic FDHA (PFDHA), which is an empirical approach based on still quite limited database. Therefore a basic and crucial improvement is to increase the database. In 2015, IAEA produced a TecDoc-1767 on Palaeoseismology as a reference for the identification of capable faults. Another IAEA Safety Report 85 on ground motion simulation based on fault rupture modelling provides an annex introducing recent PFDHAs and fault displacement simulation methodologies. The IAEA expanded the project of FDHA for the probabilistic approach and the physics based fault rupture modelling. The first approach needs a refinement of the empirical methods by building a world wide database, and the second approach needs to shift from kinematic to the dynamic scheme. Both approaches can complement each other, since simulated displacement can fill the gap of a sparse database and geological observations can be useful to calibrate the simulations. The IAEA already supported a workshop in October 2015 to discuss the existing databases with the aim of creating a common worldwide database. A consensus of a unified database was reached. The next milestone is to fill the database with as many fault rupture data sets as possible. Another IAEA work group had a WS in November 2015 to discuss the state-of-the-art PFDHA as well as simulation methodologies. Two groups jointed a consultancy meeting in February 2016, shared information, identified issues, discussed goals and outputs, and scheduled future meetings. Now we may aim at coordinating activities for the whole FDHA tasks jointly.

  14. Parameter-based estimation of CT dose index and image quality using an in-house android™-based software

    NASA Astrophysics Data System (ADS)

    Mubarok, S.; Lubis, L. E.; Pawiro, S. A.

    2016-03-01

    Compromise between radiation dose and image quality is essential in the use of CT imaging. CT dose index (CTDI) is currently the primary dosimetric formalisms in CT scan, while the low and high contrast resolutions are aspects indicating the image quality. This study was aimed to estimate CTDIvol and image quality measures through a range of exposure parameters variation. CTDI measurements were performed using PMMA (polymethyl methacrylate) phantom of 16 cm diameter, while the image quality test was conducted by using catphan ® 600. CTDI measurements were carried out according to IAEA TRS 457 protocol using axial scan mode, under varied parameters of tube voltage, collimation or slice thickness, and tube current. Image quality test was conducted accordingly under the same exposure parameters with CTDI measurements. An Android™ based software was also result of this study. The software was designed to estimate the value of CTDIvol with maximum difference compared to actual CTDIvol measurement of 8.97%. Image quality can also be estimated through CNR parameter with maximum difference to actual CNR measurement of 21.65%.

  15. Mla- and Rom1-mediated control of microRNA398 and chloroplast copper/zinc superoxide dismutase regulates cell death in response to the barley powdery mildew fungus.

    PubMed

    Xu, Weihui; Meng, Yan; Wise, Roger P

    2014-03-01

    • Barley (Hordeum vulgare L.) Mildew resistance locus a (Mla) confers allele-specific interactions with natural variants of the ascomycete fungus Blumeria graminis f. sp. hordei (Bgh), the causal agent of powdery mildew disease. Significant reprogramming of Mla-mediated gene expression occurs upon infection by this obligate biotrophic pathogen. • We utilized a proteomics-based approach, combined with barley mla, required for Mla12 resistance1 (rar1), and restoration of Mla resistance1 (rom1) mutants, to identify components of Mla-directed signaling. • Loss-of-function mutations in Mla and Rar1 both resulted in the reduced accumulation of chloroplast copper/zinc superoxide dismutase 1 (HvSOD1), whereas loss of function in Rom1 re-established HvSOD1 levels. In addition, both Mla and Rom1 negatively regulated hvu-microRNA398 (hvu-miR398), and up-regulation of miR398 was coupled to reduced HvSOD1 expression. Barley stripe mosaic virus (BSMV)-mediated over-expression of both barley and Arabidopsis miR398 repressed accumulation of HvSOD1, and BSMV-induced gene silencing of HvSod1 impeded Mla-triggered H₂O₂ and hypersensitive reaction (HR) at barley-Bgh interaction sites. • These data indicate that Mla- and Rom1-regulated hvu-miR398 represses HvSOD1 accumulation, influencing effector-induced HR in response to the powdery mildew fungus. No claim to original US Government works. New Phytologist © 2013 New Phytologist Trust.

  16. Strengthening IAEA Safeguards for Research Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reid, Bruce D.; Anzelon, George A.; Budlong-Sylvester, Kory

    During their December 10-11, 2013, workshop in Grenoble France, which focused on the history and future of safeguarding research reactors, the United States, France and the United Kingdom (UK) agreed to conduct a joint study exploring ways to strengthen the IAEA’s safeguards approach for declared research reactors. This decision was prompted by concerns about: 1) historical cases of non-compliance involving misuse (including the use of non-nuclear materials for production of neutron generators for weapons) and diversion that were discovered, in many cases, long after the violations took place and as part of broader pattern of undeclared activities in half amore » dozen countries; 2) the fact that, under the Safeguards Criteria, the IAEA inspects some reactors (e.g., those with power levels under 25 MWt) less than once per year; 3) the long-standing precedent of States using heavy water research reactors (HWRR) to produce plutonium for weapons programs; 4) the use of HEU fuel in some research reactors; and 5) various technical characteristics common to some types of research reactors that could provide an opportunity for potential proliferators to misuse the facility or divert material with low probability of detection by the IAEA. In some research reactors it is difficult to detect diversion or undeclared irradiation. In addition, infrastructure associated with research reactors could pose a safeguards challenge. To strengthen the effectiveness of safeguards at the State level, this paper advocates that the IAEA consider ways to focus additional attention and broaden its safeguards toolbox for research reactors. This increase in focus on the research reactors could begin with the recognition that the research reactor (of any size) could be a common path element on a large number of technically plausible pathways that must be considered when performing acquisition pathway analysis (APA) for developing a State Level Approach (SLA) and Annual Implementation Plan

  17. Training activities at FSUE 'RADON' and Lomonosov's Moscow state university under practical arrangements with IAEA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batyukhnova, O.G.; Karlina, O.K.; Neveykin, P.P.

    The International Education Training Centre (IETC) at Moscow Federal State Unitary Enterprise (FSUE) 'Radon', in co-operation with the International Atomic Energy Agency (IAEA), has developed expertise and provided training to waste management personnel for the last 15 years. Since 1997, the educational system of the enterprise with the support of the IAEA has acquired an international character: more than 470 experts from 35 countries - IAEA Member States completed the professional development. Training is conducted at various thematic courses or fellowships for individual programs and seminars on IAEA technical projects. In June 2008 a direct agreement (Practical Arrangements) has beenmore » signed between FSUE 'Radon' and the IAEA on cooperation in the field of development of new technologies, expert's advice to IAEA Member States, and, in particular, the training of personnel in the field of radioactive waste management (RWM), which opens up new perspectives for fruitful cooperation of industry professionals. A similar agreement - Practical Arrangements - has been signed between Lomonosov's MSU and the IAEA in 2012. In October 2012 a new IAEA two-weeks training course started at Lomonosov's MSU and FSUE 'Radon' in the framework of the Practical Agreements signed. Pre-disposal management of waste was the main topic of the courses. The paper summarizes the current experience of the FSUE 'Radon' in the organization and implementation of the IAEA sponsored training and others events and outlines some of strategic educational elements, which IETC will continue to pursue in the coming years. (authors)« less

  18. 77 FR 6094 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ....-International Atomic Energy Agency Additional Protocol. Under the U.S.-International Atomic Energy Agency (IAEA...-related activities to the IAEA and potentially provide access to IAEA inspectors for verification purposes. The U.S.-IAEA Additional Protocol permits the United States unilaterally to declare exclusions from...

  19. IAEA programs in empowering the nuclear medicine profession through online educational resources.

    PubMed

    Pascual, Thomas Nb; Dondi, Maurizio; Paez, Diana; Kashyap, Ravi; Nunez-Miller, Rodolfo

    2013-05-01

    The International Atomic Energy Agency's (IAEA) programme in human health aims to enhance the capabilities in Member States to address needs related to the prevention, diagnosis, and treatment of diseases through the application of nuclear techniques. It has the specific mission of fostering the application of nuclear medicine techniques as part of the clinical management of certain types of diseases. Attuned to the continuous evolution of this specialty as well as to the advancement and diversity of methods in delivering capacity building efforts in this digital age, the section of nuclear medicine of the IAEA has enhanced its program by incorporating online educational resources for nuclear medicine professionals into its repertoire of projects to further its commitment in addressing the needs of its Member States in the field of nuclear medicine. Through online educational resources such as the Human Health Campus website, e-learning modules, and scheduled interactive webinars, a validation of the commitment by the IAEA in addressing the needs of its Member States in the field of nuclear medicine is strengthened while utilizing the advanced internet and communications technology which is progressively becoming available worldwide. The Human Health Campus (www.humanhealth.iaea.org) is the online educational resources initiative of the Division of Human Health of the IAEA geared toward enhancing professional knowledge of health professionals in radiation medicine (nuclear medicine and diagnostic imaging, radiation oncology, and medical radiation physics), and nutrition. E-learning modules provide an interactive learning environment to its users while providing immediate feedback for each task accomplished. Webinars, unlike webcasts, offer the opportunity of enhanced interaction with the learners facilitated through slide shows where the presenter guides and engages the audience using video and live streaming. This paper explores the IAEA's available online

  20. Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations.

    PubMed

    Beigi, Manije; Afarande, Fatemeh; Ghiasi, Hosein

    2016-01-01

    The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator. High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. From designed door's thickness, the door designed by the MC simulation and Wu-McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained. Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations.

  1. Professor Glyn O. Phillip's legacy within the IAEA programme on radiation and tissue banking.

    PubMed

    Morales Pedraza, Jorge

    2017-08-19

    Professor Phillips began his involvement in the implementation of this important IAEA programme, insisting that there were advantages to be gained by using the ionizing radiation technique to sterilize human and animal tissues, based on the IAEA experience gained in the sterilization of medical products. The outcome of the implementation of the IAEA programme on radiation and tissue banking demonstrated that Professor Phillips was right in his opinion.

  2. Reducing the risks from radon indoors: an IAEA perspective.

    PubMed

    Boal, T; Colgan, P A

    2014-07-01

    The IAEA has a mandate to develop, in collaboration with other relevant international organisations, 'standards of safety for protection of health and minimisation of danger to life and property', and to provide for the application of these standards. The most recent edition of the International Basic Safety Standards includes, for the first time, requirements to protect the public from exposure due to radon indoors. As a result, the IAEA has already developed guidance material in line with accepted best international practice and an international programme to assist its Member States in identifying and addressing high radon concentrations in buildings is being prepared. This paper overviews the current situation around the world and summarises the management approach advocated by the IAEA. A number of important scientific and policy issues are identified and discussed from the point-of-view of how they may impact on national action plans and strategies. Finally, the assistance and support available through the Agency is described. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Assessment of Alternative Funding Mechanisms for the IAEA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toomey, Christopher; Wyse, Evan T.; Kurzrok, Andrew J.

    While the International Atomic Energy Agency (IAEA) has enjoyed substantial success and prestige in the international community, there is growing concern that global demographic trends, advances in technology and the trend towards austerity in Member State budgets will stretch the Agency’s resources to a point where it may no longer be possible to execute its multifaceted mission in its entirety. As part of an ongoing effort by the Next Generation Safeguards Initiative to evaluate the IAEA’s long-term budgetary concerns , this paper proposes a series of alternate funding mechanisms that have the potential to sustain the IAEA in the long-term,more » including endowment, charity, and fee-for-service funding models.« less

  4. Coordinated Research Projects of the IAEA Atomic and Molecular Data Unit

    NASA Astrophysics Data System (ADS)

    Braams, B. J.; Chung, H.-K.

    2011-05-01

    The IAEA Atomic and Molecular Data Unit is dedicated to the provision of databases for atomic, molecular and plasma-material interaction (AM/PMI) data that are relevant for nuclear fusion research. IAEA Coordinated Research Projects (CRPs) are the principal mechanism by which the Unit encourages data evaluation and the production of new data. Ongoing and planned CRPs on AM/PMI data are briefly described here.

  5. A bibliometric analysis on tobacco regulation investigators.

    PubMed

    Li, Dingcheng; Okamoto, Janet; Liu, Hongfang; Leischow, Scott

    2015-01-01

    To facilitate the implementation of the Family Smoking Prevention and Tobacco Control Act of 2009, the Federal Drug Agency (FDA) Center for Tobacco Products (CTP) has identified research priorities under the umbrella of tobacco regulatory science (TRS). As a newly integrated field, the current boundaries and landscape of TRS research are in need of definition. In this work, we conducted a bibliometric study of TRS research by applying author topic modeling (ATM) on MEDLINE citations published by currently-funded TRS principle investigators (PIs). We compared topics generated with ATM on dataset collected with TRS PIs and topics generated with ATM on dataset collected with a TRS keyword list. It is found that all those topics show a good alignment with FDA's funding protocols. More interestingly, we can see clear interactive relationships among PIs and between PIs and topics. Based on those interactions, we can discover how diverse each PI is, how productive they are, which topics are more popular and what main components each topic involves. Temporal trend analysis of key words shows the significant evaluation in four prime TRS areas. The results show that ATM can efficiently group articles into discriminative categories without any supervision. This indicates that we may incorporate ATM into author identification systems to infer the identity of an author of articles using topics generated by the model. It can also be useful to grantees and funding administrators in suggesting potential collaborators or identifying those that share common research interests for data harmonization or other purposes. The incorporation of temporal analysis can be employed to assess the change over time in TRS as new projects are funded and the extent to which new research reflects the funding priorities of the FDA.

  6. Developments in Assisting Countries in Implementing the IAEA Additional Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killinger, Mark H.; Hansen, Linda H.; Cain, Ronald A.

    In 2008, the U.S. Department of Energy (DOE) began assisting selected non-nuclear weapon states in planning and preparing for implementation of the International Atomic Energy Agency’s Additional Protocol (AP). Since then, the AP international implementation program has contributed to the substantial progress made by Vietnam, Thailand, Iraq, and Malaysia in preparing for entry-into-force of the AP. An overall engagement plan has been developed with components designed to train government AP implementing agencies, inform policy makers, conduct outreach to industry and universities, make AP reporting software available and useful, and plan a detailed approach for implementing the declaration and complementary accessmore » provisions of the AP. DOE recently began collaborating with Indonesia, which has already entered the AP into force, requiring a second method of engagement somewhat different from that taken with countries that have not entered the AP into force. The AP international implementation program, administered by the International Nuclear Safeguards and Engagement Program, is working more closely with DOE’s International Nonproliferation Export Control Program to ensure countries are aware of and prepared to implement the export/import provisions of the AP. As the AP implementation program matures and helps move countries closer to entry-into-force or improved AP implementation, it is identifying characteristics of a country’s “end-state” that indicate that DOE assistance is no longer required. The U.S. AP Implementation Act and Senate Resolution of Ratification require the Administration to report annually to Congress on measures taken to achieve the adoption of the AP in non-nuclear weapon states. DOE’s AP international implementation program is a significant part of these measures. This paper describes recent developments to increase the scope and effectiveness of the program.« less

  7. IAEA activities related to radiation biology and health effects of radiation.

    PubMed

    Wondergem, Jan; Rosenblatt, Eduardo

    2012-03-01

    The IAEA is involved in capacity building with regard to the radiobiological sciences in its member states through its technical cooperation programme. Research projects/programmes are normally carried out within the framework of coordinated research projects (CRPs). Under this programme, two CRPs have been approved which are relevant to nuclear/radiation accidents: (1) stem cell therapeutics to modify radiation-induced damage to normal tissue, and (2) strengthening biological dosimetry in IAEA member states.

  8. Methicillin-Resistant Staphylococcus aureus CC398 in Humans and Pigs in Norway: A "One Health" Perspective on Introduction and Transmission.

    PubMed

    Grøntvedt, Carl Andreas; Elstrøm, Petter; Stegger, Marc; Skov, Robert Leo; Skytt Andersen, Paal; Larssen, Kjersti Wik; Urdahl, Anne Margrete; Angen, Øystein; Larsen, Jesper; Åmdal, Solfrid; Løtvedt, Siri Margrete; Sunde, Marianne; Bjørnholt, Jørgen Vildershøj

    2016-12-01

     Emerging livestock-associated methicillin-resistant Staphylococcus aureus (MRSA) persist in livestock populations and represent a reservoir for transmission to humans. Understanding the routes of introduction and further transmission is crucial to control this threat to human health.  All reported cases of livestock-associated MRSA (CC398) in humans and pigs in Norway between 2008 and 2014 were included. Data were collected during an extensive outbreak investigation, including contact tracing and stringent surveillance. Whole-genome sequencing of isolates from all human cases and pig farms was performed to support and expand the epidemiological findings. The national strategy furthermore included a "search-and-destroy" policy at the pig farm level.  Three outbreak clusters were identified, including 26 pig farms, 2 slaughterhouses, and 36 humans. Primary introductions likely occurred by human transmission to 3 sow farms with secondary transmission to other pig farms, mainly through animal trade and to a lesser extent via humans or livestock trucks. All MRSA CC398 isolated from humans without an epidemiological link to the outbreaks were genetically distinct from isolates within the outbreak clusters indicating limited dissemination to the general population.  This study identified preventable routes of MRSA CC398 introduction and transmission: human occupational exposure, trade of pigs and livestock transport vehicles. These findings are essential for keeping pig populations MRSA free and, from a "One Health" perspective, preventing pig farms from becoming reservoirs for MRSA transmission to humans. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.

  9. Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations

    PubMed Central

    Beigi, Manije; Afarande, Fatemeh; Ghiasi, Hosein

    2016-01-01

    Aim The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator. Background High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. Materials and methods The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. Results From designed door's thickness, the door designed by the MC simulation and Wu–McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained. Conclusion Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations. PMID:26900357

  10. Methicillin-Resistant Staphylococcus aureus CC398 in Humans and Pigs in Norway: A “One Health” Perspective on Introduction and Transmission

    PubMed Central

    Grøntvedt, Carl Andreas; Elstrøm, Petter; Stegger, Marc; Skov, Robert Leo; Skytt Andersen, Paal; Larssen, Kjersti Wik; Urdahl, Anne Margrete; Angen, Øystein; Larsen, Jesper; Åmdal, Solfrid; Løtvedt, Siri Margrete; Sunde, Marianne; Bjørnholt, Jørgen Vildershøj

    2016-01-01

    Background. Emerging livestock-associated methicillin-resistant Staphylococcus aureus (MRSA) persist in livestock populations and represent a reservoir for transmission to humans. Understanding the routes of introduction and further transmission is crucial to control this threat to human health. Methods. All reported cases of livestock-associated MRSA (CC398) in humans and pigs in Norway between 2008 and 2014 were included. Data were collected during an extensive outbreak investigation, including contact tracing and stringent surveillance. Whole-genome sequencing of isolates from all human cases and pig farms was performed to support and expand the epidemiological findings. The national strategy furthermore included a “search-and-destroy” policy at the pig farm level. Results. Three outbreak clusters were identified, including 26 pig farms, 2 slaughterhouses, and 36 humans. Primary introductions likely occurred by human transmission to 3 sow farms with secondary transmission to other pig farms, mainly through animal trade and to a lesser extent via humans or livestock trucks. All MRSA CC398 isolated from humans without an epidemiological link to the outbreaks were genetically distinct from isolates within the outbreak clusters indicating limited dissemination to the general population. Conclusions. This study identified preventable routes of MRSA CC398 introduction and transmission: human occupational exposure, trade of pigs and livestock transport vehicles. These findings are essential for keeping pig populations MRSA free and, from a “One Health” perspective, preventing pig farms from becoming reservoirs for MRSA transmission to humans. PMID:27516381

  11. The IAEA neutron coincidence counting (INCC) and the DEMING least-squares fitting programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krick, M.S.; Harker, W.C.; Rinard, P.M.

    1998-12-01

    Two computer programs are described: (1) the INCC (IAEA or International Neutron Coincidence Counting) program and (2) the DEMING curve-fitting program. The INCC program is an IAEA version of the Los Alamos NCC (Neutron Coincidence Counting) code. The DEMING program is an upgrade of earlier Windows{reg_sign} and DOS codes with the same name. The versions described are INCC 3.00 and DEMING 1.11. The INCC and DEMING codes provide inspectors with the software support needed to perform calibration and verification measurements with all of the neutron coincidence counting systems used in IAEA inspections for the nondestructive assay of plutonium and uranium.

  12. Training of interventional cardiologists in radiation protection--the IAEA's initiatives.

    PubMed

    Rehani, Madan M

    2007-01-08

    The International Atomic Energy Agency (IAEA) has initiated a major international initiative to train interventional cardiologists in radiation protection as a part of its International Action Plan on the radiological protection of patients. A simple programme of two days' training has been developed, covering possible and observed radiation effects among patients and staff, international standards, dose management techniques, examples of good and bad practice and examples indicating prevention of possible injuries as a result of good practice of radiation protection. The training material is freely available on CD from the IAEA. The IAEA has conducted two events in 2004 and 2005 and number of events are planned in 2006. The survey conducted among the cardiologists participating in these programmes indicates that over 80% of them were attending such a structured programme on radiation protection for the first time. As the magnitude of X-ray usage in cardiology grows to match that in interventional radiology, the standards of training on radiation effects, radiation physics and radiation protection in interventional cardiology should also match those in interventional radiology.

  13. Striatal output markers do not alter in response to circling behaviour in 6-OHDA lesioned rats produced by acute or chronic administration of the monoamine uptake inhibitor BTS 74 398.

    PubMed

    Lane, E L; Cheetham, S; Jenner, P

    2008-01-01

    The monoamine uptake inhibitor BTS 74 398 induces ipsilateral circling in 6-hydroxydopamine (6-OHDA) lesioned rats without induction of abnormal motor behaviours associated with L-dopa administration. We examined whether this was reflected in the expression of peptide mRNA in the direct and indirect striatal output pathways.6-OHDA lesioning of the nigrostriatal pathway increased striatal expression of PPE-A mRNA and decreased levels of PPT mRNA with PPE-B mRNA expression remaining unchanged. Acute L-dopa administration normalised PPE-A mRNA and elevated PPT mRNA while PPE-B mRNA expression remained unchanged. Acute administration of BTS 74 398 did not alter striatal peptide mRNA levels. Following chronic treatment with L-dopa, PPE-A mRNA expression in the lesioned striatum continued to be normalised and PPT mRNA was increased compared to the intact side. PPE-B mRNA expression was also markedly increased relative to the non-lesioned striatum. Chronic BTS 74 398 administration did not alter mRNA expression in the 6-OHDA lesioned striatum although small increases in PPT mRNA expression in the intact and sham lesioned striatum were observed. The failure of BTS 74 398 to induce changes in striatal neuropeptide mRNA correlated with its failure to induce abnormal motor behaviours or behavioural sensitisation but does not explain how it produces a reversal of motor deficits. An action in another area of the brain appears likely and may explain the subsequent failure of BTS 74 398 and related compounds to exert anti-parkinsonian actions in man.

  14. Rise of CC398 Lineage of Staphylococcus aureus among Infective Endocarditis Isolates Revealed by Two Consecutive Population-Based Studies in France

    PubMed Central

    Tristan, Anne; Rasigade, Jean-Philippe; Ruizendaal, Esmée; Laurent, Frédéric; Bes, Michèle; Meugnier, Hélène; Lina, Gérard; Etienne, Jerome; Celard, Marie; Tattevin, Pierre; Monecke, Stefan; Le Moing, Vincent; Vandenesch, François

    2012-01-01

    Staphylococcus aureus isolates from two prospective studies on infective endocarditis (IE) conducted in 1999 and 2008 and isolated from non-IE bacteremia collected in 2006 were spa-typed and their virulence factors were analyzed with a microarray. Both populations were genetically diverse, with no virulence factors or genotypes significantly more associated with the IE isolates compared with the non-IE isolates. The population structure of the IE isolates did not change much between 1999 and 2008, with the exception of the appearance of CC398 methicillin-susceptible Staphylococcus aureus (MSSA) isolates responsible for 5.6% of all cases in 2008. In 1999, this lineage was responsible for no cases. The increasing prevalence of S. aureus in IE is apparently not the result of a major change in staphylococcal population structure over time, with the exception of the emerging CC398 MSSA lineage. PMID:23272091

  15. The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pepper S. E.; .; Worrall, L.

    2014-08-08

    The U.S. National Nuclear Security Administration’s Next Generation Safeguards Initiative, the U.S. Department of State, and the International Atomic Energy Agency (IAEA) organized a a workshop on the subject of ”Software Sustainability for Safeguards Instrumentation.” The workshop was held at the Vienna International Centre in Vienna, Austria, May 6-8, 2014. The workshop participants included software and hardware experts from national laboratories, industry, government, and IAEA member states who were specially selected by the workshop organizers based on their experience with software that is developed for the control and operation of safeguards instrumentation. The workshop included presentations, to orient the participantsmore » to the IAEA Department of Safeguards software activities related to instrumentation data collection and processing, and case studies that were designed to inspire discussion of software development, use, maintenance, and upgrades in breakout sessions and to result in recommendations for effective software practices and management. This report summarizes the results of the workshop.« less

  16. Contribution to fusion research from IAEA coordinated research projects and joint experiments

    NASA Astrophysics Data System (ADS)

    Gryaznevich, M.; Van Oost, G.; Stöckel, J.; Kamendje, R.; Kuteev, B. N.; Melnikov, A.; Popov, T.; Svoboda, V.; The IAEA CRP Teams

    2015-10-01

    The paper presents objectives and activities of IAEA Coordinated Research Projects ‘Conceptual development of steady-state compact fusion neutron sources’ and ‘Utilisation of a network of small magnetic confinement fusion devices for mainstream fusion research’. The background and main projects of the CRP on FNS are described in detail, as this is a new activity at IAEA. Recent activities of the second CRP, which continues activities of previous CRPs, are overviewed.

  17. Analysis of historical delta values for IAEA/LANL NDA training courses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, William; Santi, Peter; Swinhoe, Martyn

    2009-01-01

    The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector,more » the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.« less

  18. INF and IAEA: A comparative analysis of verification strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scheinman, L.; Kratzer, M.

    1992-07-01

    This is the final report of a study on the relevance and possible lessons of Intermediate Range Nuclear Force (INF) verification to the International Atomic Energy Agency (IAEA) international safeguards activities.

  19. 77 FR 2713 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ...) Package Title: U.S. Declaration under the Protocol Additional to the U.S.-IAEA Safeguards Agreement... Declaration to the International Atomic Energy Agency (IAEA) under Articles 2 and 3 of the Protocol Additional... performing activities at DOE Locations that would be declarable to the IAEA under the U.S. AP are affected by...

  20. The Combined Utility of a Brief Functional Measure and Performance-Based Screening Test for Case Finding of Cognitive Impairment in Primary Healthcare.

    PubMed

    Chan, Qun Lin; Shaik, Muhammad Amin; Xu, Jing; Xu, Xin; Chen, Christopher Li-Hsian; Dong, YanHong

    2016-04-01

    Use of a total risk score (TRS) based on vascular and sociodemographic risk factors has been recommended to identify patients at risk of cognitive impairment. Moreover, combining screening tests has been reported to improve positive predictive values (PPV) for case finding of cognitive impairment. We investigated the utility of the conjunctive combination of the informant-based AD8 and the performance-based National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN) 5-minute protocol for the detection of cognitive impairment, defined by a clinical dementia rating (CDR) score ≥0.5, in patients at risk of cognitive impairment (TRS ≥3). Participants were recruited from 2 primary healthcare centers in Singapore and received the AD8, Montreal Cognitive Assessment, Mini-Mental State Examination, CDR, and a formal neuropsychological test battery. The scores for NINDS-CSN 5-minute protocol were extracted from the Montreal Cognitive Assessment items. Area under the receiver operating characteristics curve analyses were conducted to determine the discriminant indices of the screening instruments, the conjunctive combination (ie, screened positive on both tests), and the compensatory combination (ie, screened positive in either of or both tests). A total of 309 participants were recruited of whom 78.7% (n = 243) had CDR = 0 and 21.3% (n = 66) had CDR ≥0.5. The conjunctive combination of AD8 and NINDS-CSN 5-minute protocol achieved excellent PPV and acceptable sensitivity (PPV 91.7%, sensitivity 73.3%). The conjunctive combination of the AD8 and NINDS-CSN 5-minute protocol is brief and accurate, and hence, suitable for case finding of cognitive impairment (CDR ≥0.5) in patients screened positive on the TRS in primary healthcare centers. Copyright © 2016. Published by Elsevier Inc.

  1. IAEA Nuclear Data Section: provision of atomic and nuclear databases for user applications.

    PubMed

    Humbert, Denis P; Nichols, Alan L; Schwerer, Otto

    2004-01-01

    The Nuclear Data Section (NDS) of the International Atomic Energy Agency (IAEA) provides a wide range of atomic and nuclear data services to scientists worldwide, with particular emphasis placed on the needs of developing countries. Highly focused Co-ordinated Research Projects and multinational data networks are sponsored under the auspices of the IAEA for the development and assembly of databases through the organised participation of specialists from Member States. More than 100 data libraries are readily available cost-free through the Internet, CD-ROM and other media. These databases are used in a wide range of applications, including fission- and fusion-energy, non-energy applications and basic research studies. Further information concerning the various services can be found through the web address of the IAEA Nuclear Data Section: and a mirror site at IPEN, Brazil that is maintained by NDS staff:.

  2. Calibrated sulfur isotope abundance ratios of three IAEA sulfur isotope reference materials and V-CDT with a reassessment of the atomic weight of sulfur

    NASA Astrophysics Data System (ADS)

    Ding, T.; Valkiers, S.; Kipphardt, H.; De Bièvre, P.; Taylor, P. D. P.; Gonfiantini, R.; Krouse, R.

    2001-08-01

    Calibrated values have been obtained for sulfur isotope abundance ratios of sulfur isotope reference materials distributed by the IAEA (Vienna). For the calibration of the measurements, a set of synthetic isotope mixtures were prepared gravimetrically from high purity Ag2S materials enriched in32S, 33S, and 34S. All materials were converted into SF6 gas and subsequently, their sulfur isotope ratios were measured on the SF5+ species using a special gas source mass spectrometer equipped with a molecular flow inlet system (IRMM's Avogadro II amount comparator). Values for the 32S/34S abundance ratios are 22.650 4(20), 22.142 4(20), and 23.393 3(17) for IAEA-S-1, IAEA-S-2, and IAEA-S-3, respectively. The calculated 32S/34S abundance ratio for V-CDT is 22.643 6(20), which is very close to the calibrated ratio obtained by Ding et al. (1999). In this way, the zero point of the VCDT scale is anchored firmly to the international system of units SI. The 32S/33S abundance ratios are 126.942(47), 125.473(55), 129.072(32), and 126.948(47) for IAEA-S-1, IAEA-S-2, IAEA-S-3, and V-CDT, respectively. In this way, the linearity of the V-CDT scale is improved over this range. The values of the sulfur molar mass for IAEA-S-1 and V-CDT were calculated to be 32.063 877(56) and 32.063 911(56), respectively, the values with the smallest combined uncertainty ever reported for the sulfur molar masses (atomic weights).

  3. Proficiency Testing as a tool to monitor consistency of measurements in the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meghzifene, Ahmed; Czap, Ladislav; Shortt, Ken

    2008-08-14

    The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) established a Network of Secondary Standards Dosimetry Laboratories (IAEA/WHO SSDL Network) in 1976. Through SSDLs designated by Member States, the Network provides a direct link of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM). Within this structure and through the proper calibration of field instruments, the SSDLs disseminate S.I. quantities and units.To ensure that the services provided by SSDL members to end-users follow internationally accepted standards, the IAEA has set up two different comparison programmes. Onemore » programme relies on the IAEA/WHO postal TLD service and the other uses comparisons of calibrated ionization chambers to help the SSDLs verify the integrity of their national standards and the procedures used for the transfer of the standards to the end-users. The IAEA comparisons include {sup 60}Co air kerma (N{sub K}) and absorbed dose to water (N{sub D,W}) coefficients. The results of the comparisons are confidential and are communicated only to the participants. This is to encourage participation of the laboratories and their full cooperation in the reconciliation of any discrepancy.This work describes the results of the IAEA programme comparing calibration coefficients for radiotherapy dosimetry, using ionization chambers. In this programme, ionization chambers that belong to the SSDLs are calibrated sequentially at the SSDL, at the IAEA, and again at the SSDL. As part of its own quality assurance programme, the IAEA has participated in several regional comparisons organized by Regional Metrology Organizations.The results of the IAEA comparison programme show that the majority of SSDLs are capable of providing calibrations that fall inside the acceptance level of 1.5% compared to the IAEA.« less

  4. Structural and electrochemical properties of the doped spinels Li 1.05M 0.02Mn 1.98O 3.98N 0.02 (M = Ga 3+, Al 3+, or Co 3+; N = S 2- or F -) for use as cathode material in lithium batteries

    NASA Astrophysics Data System (ADS)

    Amaral, Fábio A.; Bocchi, Nerilso; Brocenschi, Ricardo F.; Biaggio, Sonia R.; Rocha-Filho, Romeu C.

    The doped and milled spinels Li 1.05M 0.02Mn 1.98O 3.98N 0.02 (M = Ga 3+, Al 3+ or Co 3+; N = S 2- or F -) are studied aiming at obtaining an improved charge/discharge cycling performance. These spinels are prepared by a solid-state reaction among the precursors ɛ-MnO 2, LiOH, and the respective oxide/salt of the doping ions at 750 °C for 72 h and milled for 30 min. The obtained spinels are characterized by XRD, SEM, and determinations of the average manganese valence n. In the charge and discharge tests, the doped spinels present outstanding initial values of the specific discharge capacity C (117-126 mA h g -1), decreasing in the following order: C(Li 1.05Al 0.02Mn 1.98S 3.02O 3.98) > C(Li 1.05Al 0.02Mn 1.98F 3.02O 3.98) > C(Li 1.05Ga 0.02Mn 1.98S 3.02O 3.98) > C(Li 1.05Ga 0.02Mn 1.98F 3.02O 3.98) > C(Li 1.05Co 0.02Mn 1.98S 3.02O 3.98) > C(Li 1.05Co 0.02Mn 1.98F 3.02O 3.98). The doped spinel Li 1.05Ga 0.02Mn 1.98S 3.02O 3.98 presents an excellent electrochemical performance, with a low capacity loss even after 300 charge and discharge cycles (from 120 to 115 mA h g -1 or 4%).

  5. 47 CFR 64.613 - Numbering directory for Internet-based TRS users.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the user's Internet Protocol (IP) address. For each record associated with an IP Relay user, the URI... a VRS user's geographically appropriate NANP telephone number, the URI shall contain the IP address of the user's device. For each record associated with an IP Relay user's geographically appropriate...

  6. Livestock-associated Methicillin-Resistant Staphylococcus aureus Sequence Type 398 in Humans, Canada

    PubMed Central

    Golding, George R.; Bryden, Louis; Levett, Paul N.; McDonald, Ryan R.; Wong, Alice; Wylie, John; Graham, Morag R.; Tyler, Shaun; Van Domselaar, Gary; Simor, Andrew E.; Gravel, Denise

    2010-01-01

    Rates of colonization with livestock-associated methicillin-resistant Staphylococcus aureus (MRSA) sequence type 398 have been high for pigs and pig farmers in Canada, but prevalence rates for the general human population are unknown. In this study, 5 LA-MRSA isolates, 4 of which were obtained from skin and soft tissue infections, were identified from 3,687 tested MRSA isolates from persons in Manitoba and Saskatchewan, Canada. Further molecular characterization determined that these isolates all contained staphylococcal cassette chromosome (SCC) mecV, were negative for Panton-Valentine leukocidin, and were closely related by macrorestriction analysis with the restriction enzyme Cfr91. The complete DNA sequence of the SCCmec region from the isolate showed a novel subtype of SCCmecV harboring clustered regularly interspaced short palindromic repeats and associated genes. Although prevalence of livestock-associated MRSA seems to be low for the general population in Canada, recent emergence of infections resulting from this strain is of public health concern. PMID:20350371

  7. 76 FR 14662 - Notice of Public Information Collection(s) Being Reviewed by the Federal Communications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... (STS) based on the Multi-state Average Rate Structure (MARS) plan proposed by Hamilton Relay, Inc., (2... intrastate Internet-Protocol (IP) Captioned Telephone Service (IP CTS) based on the MARS plan, (3) a cost... with the MARS plan cost recovery methodology for compensation from the Fund. Specifically, TRS...

  8. The 1998 Australian external beam radiotherapy survey and IAEA/WHO TLD postal dose quality audit.

    PubMed

    Huntley, R; Izewska, J

    2000-03-01

    The results of an updated Australian survey of external beam radiotherapy centres are presented. Most of the centres provided most of the requested information. The relative caseloads of various linear accelerator photon and electron beams have not changed significantly since the previous survey in 1995. The mean age of Australian LINACs is 7.1 years and that of other radiotherapy machines is 14.7 years. Every Australian radiotherapy centre participated in a special run of the IAEA/WHO TLD postal dose quality audit program, which was provided for Australian centres by the IAEA and WHO in May 1998. The dose quoted by the centres was in nearly every case within 1.5% of the dose assessed by the IAEA. This is within the combined standard uncertainty of the IAEA TLD service (1.8%). The results confirm the accuracy and precision of radiotherapy dosimetry in Australia and the adequate dissemination of the Australian standards from ARL (now ARPANSA) to the centres. The Australian standards have recently been shown to agree with those of other countries to within 0.25% by comparison with the BIPM.

  9. The US Support Program to IAEA Safeguards Priority of Training and Human Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Queirolo,A.

    2008-06-13

    The U.S. Support Program to IAEA Safeguards (USSP) priority of training and human resources is aimed at providing the Department of Safeguards with an appropriate mixture of regular staff and extrabudgetary experts who are qualified to meet the IAEA's technical needs and to provide personnel with appropriate instruction to improve the technical basis and specific skills needed to perform their job functions. The equipment and methods used in inspection activities are unique, complex, and evolving. New and experienced safeguards inspectors need timely and effective training to perform required tasks and to learn new skills prescribed by new safeguards policies ormore » agreements. The role of the inspector has changed from that of strictly an accountant to include that of a detective. New safeguards procedures are being instituted, and therefore, experienced inspectors must be educated on these new procedures. The USSP also recognizes the need for training safeguards support staff, particularly those who maintain and service safeguards equipment (SGTS), and those who perform information collection and analysis (SGIM). The USSP is committed to supporting the IAEA with training to ensure the effectiveness of all staff members and will continue to offer its assistance in the development and delivery of basic, refresher, and advanced training courses. This paper will discuss the USSP ongoing support in the area of training and IAEA staffing.« less

  10. IAEA activities in the area of partitioning and transmutation

    NASA Astrophysics Data System (ADS)

    Stanculescu, Alexander

    2006-06-01

    Four major challenges are facing the long-term development of nuclear energy: improvement of the economic competitiveness, meeting increasingly stringent safety requirements, adhering to the criteria of sustainable development, and public acceptance. Meeting the sustainability criteria is the driving force behind the topic of this paper. In this context, sustainability has two aspects: natural resources and waste management. IAEA's activities in the area of Partitioning and Transmutation (P&T) are mostly in response to the latter. While not involving the large quantities of gaseous products and toxic solid wastes associated with fossil fuels, radioactive waste disposal is today's dominant public acceptance issue. In fact, small waste quantities permit a rigorous confinement strategy, and mined geological disposal is the strategy followed by some countries. Nevertheless, political opposition arguing that this does not yet constitute a safe disposal technology has largely stalled these efforts. One of the primary reasons cited is the long life of many of the radioisotopes generated from fission. This concern has led to increased R&D efforts to develop a technology aimed at reducing the amount and radio-toxicity of long-lived radioactive waste through transmutation in fission reactors or sub-critical systems. In the frame of the Project on Technology Advances in Fast Reactors and Accelerator-Driven Systems (ADS), the IAEA initiated a number of activities on utilization of plutonium and transmutation of long-lived radioactive waste, ADS, and deuterium-tritium plasma-driven sub-critical systems. The paper presents past accomplishments, current status and planned activities of this IAEA project.

  11. An IAEA multi-technique X-ray spectrometry endstation at Elettra Sincrotrone Trieste: benchmarking results and interdisciplinary applications.

    PubMed

    Karydas, Andreas Germanos; Czyzycki, Mateusz; Leani, Juan José; Migliori, Alessandro; Osan, Janos; Bogovac, Mladen; Wrobel, Pawel; Vakula, Nikita; Padilla-Alvarez, Roman; Menk, Ralf Hendrik; Gol, Maryam Ghahremani; Antonelli, Matias; Tiwari, Manoj K; Caliri, Claudia; Vogel-Mikuš, Katarina; Darby, Iain; Kaiser, Ralf Bernd

    2018-01-01

    The International Atomic Energy Agency (IAEA) jointly with the Elettra Sincrotrone Trieste (EST) operates a multipurpose X-ray spectrometry endstation at the X-ray Fluorescence beamline (10.1L). The facility has been available to external users since the beginning of 2015 through the peer-review process of EST. Using this collaboration framework, the IAEA supports and promotes synchrotron-radiation-based research and training activities for various research groups from the IAEA Member States, especially those who have limited previous experience and resources to access a synchrotron radiation facility. This paper aims to provide a broad overview about various analytical capabilities, intrinsic features and performance figures of the IAEA X-ray spectrometry endstation through the measured results. The IAEA-EST endstation works with monochromatic X-rays in the energy range 3.7-14 keV for the Elettra storage ring operating at 2.0 or 2.4 GeV electron energy. It offers a combination of different advanced analytical probes, e.g. X-ray reflectivity, X-ray absorption fine-structure measurements, grazing-incidence X-ray fluorescence measurements, using different excitation and detection geometries, and thereby supports a comprehensive characterization for different kinds of nanostructured and bulk materials.

  12. Testing the validity of the International Atomic Energy Agency (IAEA) safety culture model.

    PubMed

    López de Castro, Borja; Gracia, Francisco J; Peiró, José M; Pietrantoni, Luca; Hernández, Ana

    2013-11-01

    This paper takes the first steps to empirically validate the widely used model of safety culture of the International Atomic Energy Agency (IAEA), composed of five dimensions, further specified by 37 attributes. To do so, three independent and complementary studies are presented. First, 290 students serve to collect evidence about the face validity of the model. Second, 48 experts in organizational behavior judge its content validity. And third, 468 workers in a Spanish nuclear power plant help to reveal how closely the theoretical five-dimensional model can be replicated. Our findings suggest that several attributes of the model may not be related to their corresponding dimensions. According to our results, a one-dimensional structure fits the data better than the five dimensions proposed by the IAEA. Moreover, the IAEA model, as it stands, seems to have rather moderate content validity and low face validity. Practical implications for researchers and practitioners are included. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. A fatal infection caused by sequence type 398 methicillin-resistant Staphylococcus aureus carrying the Panton-Valentine leukocidin gene: A case report in Japan.

    PubMed

    Koyama, Hiroshi; Sanui, Masamitsu; Saga, Tomoo; Harada, Sohei; Ishii, Yoshikazu; Tateda, Kazuhiro; Lefor, Alan Kawarai

    2015-07-01

    Methicillin-resistant Staphylococcus aureus (MRSA) has now been recognized as a common pathogen in the community. Sequence type (ST) 398 MRSA is generally considered as an emerging zoonotic agent spreading among livestock and personnel who have direct contact with animals, mainly in Europe. A 37-year-old Chinese woman receiving steroid therapy for systemic lupus erythematosus with general fatigue and myalgia was brought to the emergency department in critical condition. Her condition deteriorated despite aggressive management and she died on day 7. Her blood culture revealed ST398 MRSA-SCCmec V with Panton-Valentine Leukocidin (PVL) gene. This is the first case report of a fatal infection caused by this lineage. According to the results of molecular analyses, the isolate from this particular patient's blood was genetically close to a lineage detected in China, and is less likely to be related to an animal-associated lineage. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Effects of indomethacin, NS-398 (a selective prostaglandin H synthase-2 inhibitor) and protein synthesis inhibitors on prostaglandin production by the guinea-pig placenta.

    PubMed

    Aitken, H; Poyser, N L

    2001-01-01

    The outputs of PGF(2 alpha), PGE2 and 6-keto-PGF(1 alpha)were similar from the day 22 guinea-pig placenta and sub-placenta in culture, except for PGE2 output from the sub-placenta which was lower. Between days 22 and 29 of pregnancy, the outputs of PGF(2 alpha), PGE2 and 6-keto-PGF(1 alpha)during the initial 2 h culture period increased 6.9-, 1.1- and 3.2-fold, respectively, from the placenta, and 2.1-, 1.4- and 2.2-fold, respectively, from the sub-placenta. Therefore, there was a relatively specific increase in PGF(2 alpha)production by the guinea-pig placenta between days 22 and 29 of pregnancy. The output of PGFM from the cultured placenta also increased between days 22 and 29, indicating that the increase in PGF(2 alpha)output was due to increased synthesis rather than to decreased metabolism. By comparing the amounts of prostaglandins produced by tissue homogenates during a 1 h incubation period, it appears that there is approximately a 2-fold increase in the amount of prostaglandin H synthase (PGHS) present in the guinea-pig placenta between days 22 and 29. NS-398 (a specific inhibitor of PGHS-2) and indomethacin (an inhibitor of both PGHS-1 and PGHS-2) both inhibited prostaglandin production by homogenates of day 22 and day 29 placenta. Indomethacin was more effective than NS-398, except for their actions on PGF(2 alpha)production by the day 29 placenta where indomethacin and NS-398 were equiactive. Indomethacin and NS-398 were both very effective at inhibiting the outputs of PGF(2 alpha), PGE2 and 6-keto-PGF(1 alpha)from the day 22 and day 29 placenta and sub-placenta in culture, indicating that prostaglandin production by the guinea-pig placenta and sub-placenta in culture is largely dependent upon the activity of PGHS-2. The high production of PGF(2 alpha)by the day 29 placenta is not dependent on the continual synthesis of fresh protein(s), as inhibitors of protein synthesis did not reduce PGF(2 alpha)output from the day 29 guinea-pig placenta in culture

  15. 75 FR 54040 - Telecommunications Relay Services and Speech-to-Speech Services for Individuals With Hearing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ... Services (TRS) mandatory minimum standards for Video Relay Service (VRS) and Internet Protocol Relay (IP... waivers for one year because the record demonstrates that it is technologically infeasible for VRS and IP... standards for VRS and IP Relay will expire on July 1, 2011, or until the Commission addresses pending...

  16. The Mailbox Computer System for the IAEA verification experiment on HEU downlending at the Portsmouth Gaseous Diffusion Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aronson, A.L.; Gordon, D.M.

    IN APRIL 1996, THE UNITED STATES (US) ADDED THE PORTSMOUTH GASEOUS DIFFUSION PLANT TO THE LIST OF FACILITIES ELIGIBLE FOR THE APPLICATION OF INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA) SAFEGUARDS. AT THAT TIME, THE US PROPOSED THAT THE IAEA CARRY OUT A ''VERIFICATION EXPERIMENT'' AT THE PLANT WITH RESPECT TO DOOWNBLENDING OF ABOUT 13 METRIC TONS OF HIGHLY ENRICHED URANIUM (HEU) IN THE FORM OF URANIUM HEXAFLUROIDE (UF6). DURING THE PERIOD DECEMBER 1997 THROUGH JULY 1998, THE IAEA CARRIED OUT THE REQUESTED VERIFICATION EXPERIMENT. THE VERIFICATION APPROACH USED FOR THIS EXPERIMENT INCLUDED, AMONG OTHER MEASURES, THE ENTRY OF PROCESS-OPERATIONAL DATA BYmore » THE FACILITY OPERATOR ON A NEAR-REAL-TIME BASIS INTO A ''MAILBOX'' COMPUTER LOCATED WITHIN A TAMPER-INDICATING ENCLOSURE SEALED BY THE IAEA.« less

  17. INF and IAEA: A comparative analysis of verification strategy. [Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scheinman, L.; Kratzer, M.

    1992-07-01

    This is the final report of a study on the relevance and possible lessons of Intermediate Range Nuclear Force (INF) verification to the International Atomic Energy Agency (IAEA) international safeguards activities.

  18. The impact of the International Atomic Energy Agency (IAEA) program on radiation and tissue banking in Argentina.

    PubMed

    Kairiyama, Eulogia; Morales Pedraza, Jorge

    2009-05-01

    Tissue banking activities in Argentina started in 1993. The regulatory and controlling national authority on organ, tissue and cells for transplantation activity is the National Unique Coordinating Central Institute for Ablation and Implant (INCUCAI). Three tissue banks were established under the IAEA program and nine other banks participated actively in the implementation of this program. As result of the implementation of the IAEA program in Argentina and the work done by the established tissue banks, more and more hospitals are now using, in a routine manner, radiation sterilised tissues processed by these banks. During the period 1992-2005, more than 21 016 tissues were produced and irradiated in the tissue banks participating in the IAEA program. Within the framework of the training component of the IAEA program, Argentina has been selected to host the Regional Training Centre for Latin American. In this centre, tissue bank operators and medical personal from Latin American countries were trained. Since 1999, Argentina has organised four regular regional training courses and two virtual regional training courses. More than twenty (20) tissue bank operators and medical personnel from Argentina were trained under the IAEA program in the six courses organised in the country. In general, ninety (96) tissue bank operators and medical personnel from eight Latin-American countries were trained in the Buenos Aires regional training centre. From Argentina 16 students graduated in these courses.

  19. Training in Tbilisi nuclear facility provides new sampling perspectives for IAEA inspectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brim, Cornelia P.

    2016-06-08

    Office of Nonproliferation and Arms Control- (NPAC-) sponsored training in a “cold” nuclear facility in Tbilisi, Georgia provides International Atomic Energy Agency (IAEA) inspectors with a new perspective on environmental sampling strategies. Sponsored by the Nuclear Safeguards program under the NPAC, Pacific Northwest National Laboratory (PNNL) experts have been conducting an annual weeklong class for IAEA inspectors in a closed nuclear facility since 2011. The Andronikashvili Institute of Physics and the Republic of Georgia collaborate with PNNL to provide the training, and the U.S. Department of State, the U.S. Embassy in Tbilisi and the U.S. Mission to International Organizations inmore » Vienna provide logistical support.« less

  20. A comparison of blood loss during the Halal slaughter of lambs following Traditional Religious Slaughter without stunning, Electric Head-Only Stunning and Post-Cut Electric Head-Only Stunning.

    PubMed

    Khalid, Rizvan; Knowles, Toby G; Wotton, Steve B

    2015-12-01

    Blood lost at exsanguination during the Halal slaughter of lambs was compared between the slaughter methods of Traditional Religious Slaughter without stunning (TRS), Electric Head-Only Stunning (EHOS) and Post-Cut Electric Head-Only Stunning (PCEHOS). Two protocols were examined, Experimental (80 lambs) and Commercial (360 lambs), assessing varying periods of animal orientation during the 4 min bleeding process (upright orientation before vertical hanging). Live-weight, blood weight (Experimental only), carcass weights and by-product weights were recorded. The Experimental protocol highlighted an increase in blood loss at 60s in EHOS and PCEHOS compared to TRS (P<0.001) but by 90 s there was no significant difference. A post-slaughter change in animal orientation from an upright to a vertical hanging position aided the amount of blood loss. The bleeding of lambs is largely completed by 2 min. There were no significant differences (P>0.05) in final blood loss between treatments. This research was undertaken to inform discussion on the merits of different slaughter methods compatible with Halal requirements. Copyright © 2015. Published by Elsevier Ltd.

  1. IAEA activities on atomic, molecular and plasma-material interaction data for fusion

    NASA Astrophysics Data System (ADS)

    Braams, Bastiaan J.; Chung, Hyun-Kyung

    2013-09-01

    The IAEA Atomic and Molecular Data Unit (http://www-amdis.iaea.org/) aims to provide internationally evaluated and recommended data for atomic, molecular and plasma-material interaction (A+M+PMI) processes in fusion research. The Unit organizes technical meetings and coordinates an A+M Data Centre Network (DCN) and a Code Centre Network (CCN). In addition the Unit organizes Coordinated Research Projects (CRPs), for which the objectives are mixed between development of new data and evaluation and recommendation of existing data. In the area of A+M data we are placing new emphasis in our meeting schedule on data evaluation and especially on uncertainties in calculated cross section data and the propagation of uncertainties through structure data and fundamental cross sections to effective rate coefficients. Following a recent meeting of the CCN it is intended to use electron scattering on Be, Ne and N2 as exemplars for study of uncertainties and uncertainty propagation in calculated data; this will be discussed further at the presentation. Please see http://www-amdis.iaea.org/CRP/ for more on our active and planned CRPs, which are concerned with atomic processes in core and edge plasma and with plasma interaction with beryllium-based surfaces and with irradiated tungsten.

  2. Trip report on IAEA Training Workshop on Implementation of Integrated Management Systems for Research Reactors (T3-TR-45496).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, Richard J.

    2013-11-01

    From 17-21 June 2013, Sandia National Laboratories, Technical Area-V (SNL TA-V) represented the United States Department of Energy/National Nuclear Security Administration (DOE/NNSA) at the International Atomic Energy Agency (IAEA) Training Workshop (T3-TR-45486). This report gives a breakdown of the IAEA regulatory structure for those unfamiliar, and the lessons learned and observations that apply to SNL TA-V that were obtained from the workshop. The Safety Report Series, IAEA workshop final report, and SNL TA-V presentation are included as attachments.

  3. Participation in proficiency test for tritium strontium and caesium isotopes in seawater 2015 (IAEA-RML-2015-02)

    NASA Astrophysics Data System (ADS)

    Visetpotjanakit, S.; Kaewpaluek, S.

    2017-06-01

    A proficiency test (PT) exercise has proposed by the International Atomic Energy Agency (IAEA) in the frame of the IAEA Technical Cooperation project RAS/7/021 “Marine benchmark study on the possible impact of the Fukushima radioactive releases in the Asia-Pacific Region for Caesium Determination in Sea Water” since 2012. In 2015 the exercise was referred to Proficiency Test for Tritium, Strontium and Caesium Isotopes in Seawater 2015 (IAEA-RML-2015-02) to analyse3H, 134Cs, 137Cs and90Sr in a seawater sample. OAP was one of the 17 laboratories from 15 countries from Asia-Pacific Region who joined the PT exercise. The aim of our participation was to validate our analytical performance for the accurate determination of radionuclides in seawater by developed methods of radiochemical analysis. OAP submitted results determining the concentration for the three elements i.e. 134Cs, 137Cs and90Sr in seawater to the IAEA. A critical review was made to check suitability of our methodology and the criteria for the accuracy, precision and trueness of our data. The results of both 134Cs and 137Cs passed all criteria which were assigned “Accepted” statuses. Whereas 90Sr analysis did not pass the accuracy test therefore it was considered as “Not accepted” Our results and all other participant results with critical comments were published in the IAEA proficiency test report.

  4. Dynamic of nasal colonization by methicillin-resistant Staphylococcus aureus ST398 and ST1 after mupirocin treatment in a family in close contact with pigs.

    PubMed

    Lozano, Carmen; Aspiroz, Carmen; Lasarte, Juan J; Gómez-Sanz, Elena; Zarazaga, Myriam; Torres, Carmen

    2011-01-01

    Nasal colonization by methicillin-resistant Staphylococcus aureus (MRSA) was evaluated after a mupirocin treatment in a family previously colonized by MRSA sequence type ST398 and ST1, who lived close to a pig farm. Eight nasal samples were swabbed from each of the four family members on different moments after mupirocin treatment. The efficacy of treatment was low in those family members who worked in the farm, and higher in the remaining two family members with sporadic contact with pigs. In addition, nasal and skin swabs from randomly selected pigs of the farm were taken. MRSA were detected in 33% of pigs tested. All MRSA isolates obtained were characterized by Staphylococcal-Cassette-Chromosome mec (SCCmec) determination, Multilocus-Sequence-Typing (MLST), spa- and agr-typing, Pulsed-field-gel-electrophoresis (PFGE), antimicrobial susceptibility, detection of antimicrobial resistance genes, and toxin gene profiling. Spa-types t011, t1255 and t1197 were detected in humans and animals, with indistinguishable PFGE patterns, suggesting animal to human MRSA transmission. Each spa-type was ascribed to a specific pulsotype. Spa-types t127 and t108 were only detected in MRSA isolates obtained from humans, and t012 only in those from animals. MRSA ST1-t127 isolates and some ST398-t011 and ST398-t1197 isolates presented a multiantimicrobial-resistance phenotype. None of them harbored lukF/lukS, tst, eta and etb virulence genes. This study showed that the efficacy of nasal MRSA decolonization in healthy people with very close contact with pigs is especially low. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Nuclear cardiology practices and radiation exposure in Africa: results from the IAEA Nuclear Cardiology Protocols Study (INCAPS).

    PubMed

    Bouyoucef, Salah E; Mercuri, Mathew; Pascual, Thomas N; Allam, Adel H; Vangu, Mboyo; Vitola, João V; Better, Nathan; Karthikeyan, Ganesan; Mahmarian, John J; Rehani, Madan M; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiation-associated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI.

  6. Nuclear cardiology practices and radiation exposure in Africa: results from the IAEA Nuclear Cardiology Protocols Study (INCAPS)

    PubMed Central

    Bouyoucef, Salah E; Mercuri, Mathew; Einstein, Andrew J; Pascual, Thomas NB; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Allam, Adel H; Vangu, Mboyo; Vitola, João V; Better, Nathan; Karthikeyan, Ganesan; Mahmarian, John J; Rehani, Madan M; Einstein, Andrew J

    2017-01-01

    Summary Objective: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiationassociated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. Methods: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. Results: to that of the rest of the world [9.1 (5.1–15.6) vs 10.3 mSv (6.8–12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0–16.3 mSv; p < 0.0001) and QI range was 4–8. Conclusion: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI. PMID:28906538

  7. Deterring Nuclear Proliferation: The Importance of IAEA Safeguards: A TEXTBOOK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, M.D.; Fishbone, L.G.; Gallini, L.

    2012-03-13

    Nuclear terrorism and nuclear proliferation are among the most pressing challenges to international peace and security that we face today. Iran and Syria remain in non-compliance with the safeguards requirements of the NPT, and the nuclear ambitions of North Korea remain unchecked. Despite these challenges, the NPT remains a cornerstone of the nuclear non-proliferation regime, and the safeguards implemented by the International Atomic Energy Agency (IAEA) under the NPT play a critical role in deterring nuclear proliferation.How do they work? Where did they come from? And what is their future? This book answers these questions. Anyone studying the field ofmore » nuclear non-proliferation will benefit from reading this book, and for anyone entering the field, the book will enable them to get a running start. Part I describes the foundations of the international safeguards system: its origins in the 1930s - when new discoveries in physics made it clear immediately that nuclear energy held both peril and promise - through the entry into force in 1970 of the NPT, which codified the role of IAEA safeguards as a means to verify states NPT commitments not to acquire nuclear weapons. Part II describes the NPT safeguards system, which is based on a model safeguards agreement developed specifically for the NPT, The Structure and Content of Agreements between the Agency and States required in connection with the Treaty on the Non-Proliferation of Nuclear Weapons, which has been published by the IAEA as INFCIRC/153. Part III describes events, especially in South Africa, the DPRK, and Iraq in the early 1990s, that triggered a transformation in the way in which safeguards were conceptualized and implemented.« less

  8. 76 FR 24854 - Proposed Information Collection; Comment Request; Additional Protocol Report Forms

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... States to submit declaration forms to the International Atomic Energy Agency (IAEA) on a number of... purposes, but also would be necessary elements for a nuclear weapons program. These forms provides the IAEA... and milling of nuclear materials; buildings on sites of facilities selected by the IAEA from the U.S...

  9. NOTE: Monte Carlo simulation of correction factors for IAEA TLD holders

    NASA Astrophysics Data System (ADS)

    Hultqvist, Martha; Fernández-Varea, José M.; Izewska, Joanna

    2010-03-01

    The IAEA standard thermoluminescent dosimeter (TLD) holder has been developed for the IAEA/WHO TLD postal dose program for audits of high-energy photon beams, and it is also employed by the ESTRO-QUALity assurance network (EQUAL) and several national TLD audit networks. Factors correcting for the influence of the holder on the TL signal under reference conditions have been calculated in the present work from Monte Carlo simulations with the PENELOPE code for 60Co γ-rays and 4, 6, 10, 15, 18 and 25 MV photon beams. The simulation results are around 0.2% smaller than measured factors reported in the literature, but well within the combined standard uncertainties. The present study supports the use of the experimentally obtained holder correction factors in the determination of the absorbed dose to water from the TL readings; the factors calculated by means of Monte Carlo simulations may be adopted for the cases where there are no measured data.

  10. Numerical modeling of the radionuclide water pathway with HYDRUS and comparison with the IAEA model of SR 44.

    PubMed

    Merk, Rainer

    2012-02-01

    This study depicts a theoretical experiment in which the radionuclide transport through the porous material of a landfill consisting of concrete rubble (e.g., from the decommissioning of nuclear power plants) and the subsequent migration through the vadose zone and aquifer to a model well is calculated by means of the software HYDRUS-1D (Simunek et al., 2008). The radionuclides originally contained within the rubble become dissolved due to leaching caused by infiltrated rainwater. The resulting well-water contamination (in Bq/L) is calculated numerically as a function of time and location and compared with the outcome of a simplified analytic model for the groundwater pathway published by the IAEA (2005). Identical model parameters are considered. The main objective of the present work is to evaluate the predictive capacity of the more simple IAEA model using HYDRUS-1D as a reference. For most of the radionuclides considered (e.g., ¹²⁹I, and ²³⁹Pu), results from applying the IAEA model were found to be comparable to results from the more elaborate HYDRUS modeling, provided the underlying parameter values are comparable. However, the IAEA model appears to underestimate the effects resulting from, for example, high nuclide mobility, short half-life, or short-term variations in the water infiltration. The present results indicate that the IAEA model is suited for screening calculations and general recommendation purposes. However, the analysis of a specific site should be accompanied by detailed HYDRUS computer simulations. In all models considered, the calculation outcome largely depends on the choice of the sorption parameter K(d). Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Efficacy of two types of palliative sedation therapy defined using intervention protocols: proportional vs. deep sedation.

    PubMed

    Imai, Kengo; Morita, Tatsuya; Yokomichi, Naosuke; Mori, Masanori; Naito, Akemi Shirado; Tsukuura, Hiroaki; Yamauchi, Toshihiro; Kawaguchi, Takashi; Fukuta, Kaori; Inoue, Satoshi

    2018-06-01

    This study investigated the effect of two types of palliative sedation defined using intervention protocols: proportional and deep sedation. We retrospectively analyzed prospectively recorded data of consecutive cancer patients who received the continuous infusion of midazolam in a palliative care unit. Attending physicians chose the sedation protocol based on each patient's wish, symptom severity, prognosis, and refractoriness of suffering. The primary endpoint was a treatment goal achievement at 4 h: in proportional sedation, the achievement of symptom relief (Support Team Assessment Schedule (STAS) ≤ 1) and absence of agitation (modified Richmond Agitation-Sedation Scale (RASS) ≤ 0) and in deep sedation, the achievement of deep sedation (RASS ≤ - 4). Secondary endpoints included mean scores of STAS and RASS, deep sedation as a result, and adverse events. Among 398 patients who died during the period, 32 received proportional and 18 received deep sedation. The treatment goal achievement rate was 68.8% (22/32, 95% confidence interval 52.7-84.9) in the proportional sedation group vs. 83.3% (15/18, 66.1-100) in the deep sedation group. STAS decreased from 3.8 to 0.8 with proportional sedation at 4 h vs. 3.7 to 0.3 with deep sedation; RASS decreased from + 1.2 to - 1.7 vs. + 1.4 to - 3.7, respectively. Deep sedation was needed as a result in 31.3% (10/32) of the proportional sedation group. No fatal events that were considered as probably or definitely related to the intervention occurred. The two types of intervention protocol well reflected the treatment intention and expected outcomes. Further, large-scale cohort studies are promising.

  12. The evolution and impact of the International Atomic Energy Agency (IAEA) program on radiation and tissue banking in Asia and the Pacific region.

    PubMed

    Morales Pedraza, Jorge; Phillips, Glyn O

    2009-05-01

    The Asia and the Pacific region was within the IAEA program on radiation and tissue banking, the most active region. Most of the tissue banks in the Asia and the Pacific region were developed during the late 1980s and 1990s. The initial number of tissue banks established or supported by the IAEA program in the framework of the RCA Agreement for Asia and the Pacific region was 18. At the end of 2006, the number of tissue banks participating, in one way or another in the IAEA program was 59. Since the beginning of the implementation of the IAEA program in Asia and the Pacific region 63,537 amnion and 44,282 bone allografts were produced and 57,683 amnion and 36,388 bone allografts were used. The main impact of the IAEA program in the region was the following: the establishment or consolidation of at least 59 tissue banks in 15 countries in the region (the IAEA supported directly 16 of these banks); the improvement on the quality and safety of tissues procured and produced in the region reaching international standards; the implementation of eight national projects, two regional projects and two interregional projects; the elaboration of International Standards, a Code of Practice and a Public Awareness Strategies and, the application of quality control and quality assurances programs in all participating tissue banks.

  13. Co-ordination of the International Network of Nuclear Structure and Decay Data Evaluators; Summary Report of an IAEA Technical Meeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abriola, D.; Tuli, J.

    The IAEA Nuclear Data Section convened the 18th meeting of the International Network of Nuclear Structure and Decay Data Evaluators at the IAEA Headquarters, Vienna, 23 to 27 March 2009. This meeting was attended by 22 scientists from 14 Member States, plus IAEA staff, concerned with the compilation, evaluation and dissemination of nuclear structure and decay data. A summary of the meeting, recommendations/conclusions, data centre reports, and various proposals considered, modified and agreed by the participants are contained within this document. The International Network of Nuclear Structure and Decay Data (NSDD) Evaluators holds biennial meetings under the auspices of themore » IAEA, and consists of evaluation groups and data service centres in several countries. This network has the objective of providing up-to-date nuclear structure and decay data for all known nuclides by evaluating all existing experimental data. Data resulting from this international evaluation collaboration is included in the Evaluated Nuclear Structure Data File (ENSDF) and published in the journals Nuclear Physics A and Nuclear Data Sheets (NDS).« less

  14. Combination of virtual screening protocol by in silico towards the discovery of novel 4-hydroxyphenylpyruvate dioxygenase inhibitors

    NASA Astrophysics Data System (ADS)

    Fu, Ying; Sun, Yi-Na; Yi, Ke-Han; Li, Ming-Qiang; Cao, Hai-Feng; Li, Jia-Zhong; Ye, Fei

    2018-02-01

    4-Hydroxyphenylpyruvate dioxygenase (EC 1.13.11.27, HPPD) is a potent new bleaching herbicide target. Therefore, in silico structure-based virtual screening was performed in order to speed up the identification of promising HPPD inhibitors. In this study, an integrated virtual screening protocol by combining 3D-pharmacophore model, molecular docking and molecular dynamics (MD) simulation was established to find novel HPPD inhibitors from four commercial databases. 3D-pharmacophore Hypo1 model was applied to efficiently narrow potential hits. The hit compounds were subsequently submitted to molecular docking studies, showing four compounds as potent inhibitor with the mechanism of the Fe(II) coordination and interaction with Phe360, Phe403 and Phe398. MD result demonstrated that nonpolar term of compound 3881 made great contributions to binding affinities. It showed an IC50 being 2.49 µM against AtHPPD in vitro. The results provided useful information for developing novel HPPD inhibitors, leading to further understanding of the interaction mechanism of HPPD inhibitors.

  15. A review of the International Atomic Energy Agency (IAEA) international standards for tissue banks.

    PubMed

    Morales Pedraza, Jorge; Lobo Gajiwala, Astrid; Martinez Pardo, María Esther

    2012-03-01

    The IAEA International Standards for Tissue Banks published in 2003 were based on the Standards then currently in use in the USA and the European Union, among others, and reflect the best practices associated with the operation of a tissue bank. They cover legal, ethical and regulatory controls as well as requirements and procedures from donor selection and tissue retrieval to processing and distribution of finished tissue for clinical use. The application of these standards allows tissue banks to operate with the current good tissue practice, thereby providing grafts of high quality that satisfy the national and international demand for safe and biologically useful grafts. The objective of this article is to review the IAEA Standards and recommend new topics that could improve the current version.

  16. Comparison of k Q factors measured with a water calorimeter in flattening filter free (FFF) and conventional flattening filter (cFF) photon beams

    NASA Astrophysics Data System (ADS)

    de Prez, Leon; de Pooter, Jacco; Jansen, Bartel; Perik, Thijs; Wittkämper, Frits

    2018-02-01

    Recently flattening filter free (FFF) beams became available for application in modern radiotherapy. There are several advantages of FFF beams over conventional flattening filtered (cFF) beams, however differences in beam spectra at the point of interest in a phantom potentially affect the ion chamber response. Beams are also non-uniform over the length of a typical reference ion chamber and recombination is usually larger. Despite several studies describing FFF beam characteristics, only a limited number of studies investigated their effect on k Q factors. Some of those studies predicted significant discrepancies in k Q factors (0.4% up to 1.0%) if TPR20,10 based codes of practice (CoPs) were to be used. This study addresses the question to which extent k Q factors, based on a TPR20,10 CoP, can be applied in clinical reference dosimetry. It is the first study that compares k Q factors measured directly with an absorbed dose to water primary standard in FFF-cFF pairs of clinical photon beams. This was done with a transportable water calorimeter described elsewhere. The measurements corrected for recombination and beam radial non-uniformity were performed in FFF-cFF beam pairs at 6 MV and 10 MV of an Elekta Versa HD for a selection of three different Farmer-type ion chambers (eight serial numbers). The ratio of measured k Q factors of the FFF-cFF beam pairs were compared with the TPR20,10 CoPs of the NCS and IAEA and the %dd(10) x CoP of the AAPM. For the TPR20,10 based CoPs differences less than 0.23% were found in k Q factors between the corresponding FFF-cFF beams with standard uncertainties smaller than 0.35%, while for the %dd(10) x these differences were smaller than 0.46% and within the expanded uncertainty of the measurements. Based on the measurements made with the equipment described in this study the authors conclude that the k Q factors provided by the NCS-18 and IAEA TRS-398 codes of practice can be applied for flattening filter free beams without

  17. On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams.

    PubMed

    Zink, K; Wulff, J

    2011-02-01

    In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p(wall) and P(cav)) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choice of the chamber's effective point of measurement. Recommendations concerning the positioning of parallel-plate ionization chambers in clinical electron beams are not the same for all current dosimetry protocols. The IAEA TRS-398 as well as the IPEM protocol and the German protocol DIN 6800-2 interpret the depth of measurement within the phantom as the water equivalent depth, i.e., the nonwater equivalence of the entrance window has to be accounted for by shifting the chamber by an amount deltaz. This positioning should ensure that the primary electrons traveling from the surface of the water phantom through the entrance window to the chamber's reference point sustain the same energy loss as the primary electrons in the undisturbed phantom. The objective of the present study is the determination of the shift deltaz for a NACP-02 chamber and the calculation of the resulting wall perturbation correction as a function of depth. Moreover, the contributions of the different chamber walls to the wall perturbation correction are identified. The dose and fluence within the NACP-02 chamber and a wall-less air cavity is calculated using the Monte Carlo code EGSnrc in a water phantom at different depths for different clinical electron beams. In order to determine the necessary shift to account for the nonwater equivalence of the entrance window, the chamber is shifted in steps deltaz around the depth of measurement. The optimal shift deltaz is determined from a comparison of the spectral fluence within the chamber and the bare cavity. The wall perturbation correction is calculated as the ratio

  18. First reporting of methicillin-resistant Staphylococcus aureus (MRSA) ST398 in an industrial rabbit holding and in farm-related people.

    PubMed

    Agnoletti, Fabrizio; Mazzolini, Elena; Bacchin, Cosetta; Bano, Luca; Berto, Giacomo; Rigoli, Roberto; Muffato, Giovanna; Coato, Paola; Tonon, Elena; Drigo, Ilenia

    2014-05-14

    Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA) has been described in food-producing animals and farm or slaughterhouse workers involved in the primary industrial production of swine, bovine and poultry. This communication describes the first case of LA-MRSA (ST398, spa types t034 and t5210) occurring in rabbits raised intensively for meat production and involving farm workers or their family members. In 2012-2013, in a study involving 40 rabbit industrial holdings in Italy, one farm was found to have rabbits colonized or infected with MRSA. Four farm workers and one of their relatives were found to be carrying MRSA. In this case holding, rabbits, people and the holding environment were further investigated and followed up by a second sampling five months later. MRSA was found in 48% (11/23) and 25% (15/59) of the rabbits carrying S. aureus at first and second samplings, respectively. Five months after first detection, some farm workers or family members were still MRSA carriers. Surface samples (2/10) and air samples (2/3) were contaminated with MRSA. Air samples yielded MRSA counts of 5 and 15CFU/m(3). MRSA from rabbits and people collected at first sampling were spa types t034 and t5210 belonging to ST398. The MRSA isolates from rabbits and persons tested at second sampling were t034 and t5210, but spa types t1190 and t2970 were also detected in MRSA isolates from rabbits. Tracing the epidemiological pattern earlier may prevent further spread of LA-MRSA in these food producing animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Funding for the 2ND IAEA technical meeting on fusion data processing, validation and analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greenwald, Martin

    The International Atomic Energy Agency (IAEA) will organize the second Technical Meeting on Fusion Da Processing, Validation and Analysis from 30 May to 02 June, 2017, in Cambridge, MA USA. The meeting w be hosted by the MIT Plasma Science and Fusion Center (PSFC). The objective of the meeting is to provide a platform where a set of topics relevant to fusion data processing, validation and analysis are discussed with the view of extrapolation needs to next step fusion devices such as ITER. The validation and analysis of experimental data obtained from diagnostics used to characterize fusion plasmas are crucialmore » for a knowledge based understanding of the physical processes governing the dynamics of these plasmas. The meeting will aim at fostering, in particular, discussions of research and development results that set out or underline trends observed in the current major fusion confinement devices. General information on the IAEA, including its mission and organization, can be found at the IAEA websit Uncertainty quantification (UQ) Model selection, validation, and verification (V&V) Probability theory and statistical analysis Inverse problems & equilibrium reconstru ction Integrated data analysis Real time data analysis Machine learning Signal/image proc essing & pattern recognition Experimental design and synthetic diagnostics Data management« less

  20. Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries.

    PubMed

    Lindner, Oliver; Pascual, Thomas N B; Mercuri, Mathew; Acampa, Wanda; Burchert, Wolfgang; Flotats, Albert; Kaufmann, Philipp A; Kitsiou, Anastasia; Knuuti, Juhani; Underwood, S Richard; Vitola, João V; Mahmarian, John J; Karthikeyan, Ganesan; Better, Nathan; Rehani, Madan M; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    2016-04-01

    Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the

  1. Telerobotic system performance measurement - Motivation and methods

    NASA Technical Reports Server (NTRS)

    Kondraske, George V.; Khoury, George J.

    1992-01-01

    A systems performance-based strategy for modeling and conducting experiments relevant to the design and performance characterization of telerobotic systems is described. A developmental testbed consisting of a distributed telerobotics network and initial efforts to implement the strategy described is presented. Consideration is given to the general systems performance theory (GSPT) to tackle human performance problems as a basis for: measurement of overall telerobotic system (TRS) performance; task decomposition; development of a generic TRS model; and the characterization of performance of subsystems comprising the generic model. GSPT employs a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented within the framework of a distributed telerobotics network as a testbed. Insight into the design of test protocols which elicit application-independent data is described.

  2. Analysis of IAEA Environmental Samples for Plutonium and Uranium by ICP/MS in Support Of International Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farmer, Orville T.; Olsen, Khris B.; Thomas, May-Lin P.

    2008-05-01

    A method for the separation and determination of total and isotopic uranium and plutonium by ICP-MS was developed for IAEA samples on cellulose-based media. Preparation of the IAEA samples involved a series of redox chemistries and separations using TRU® resin (Eichrom). The sample introduction system, an APEX nebulizer (Elemental Scientific, Inc), provided enhanced nebulization for a several-fold increase in sensitivity and reduction in background. Application of mass bias (ALPHA) correction factors greatly improved the precision of the data. By combining the enhancements of chemical separation, instrumentation and data processing, detection levels for uranium and plutonium approached high attogram levels.

  3. Reference dosimeter system of the iaea

    NASA Astrophysics Data System (ADS)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-09-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.

  4. Dosimetric properties of a proton beamline dedicated to the treatment of ocular disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.

    2014-01-15

    Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.

    Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong

  6. Secretary of Energy Steven Chu speaks to the 2009 IAEA General Conference delegation

    ScienceCinema

    Secretary Chu

    2017-12-09

    On Sept. 14, 2009, U.S. Secretary of Energy Steven Chu addressed the 2009 IAEA General Conference delegation. Chu is the first Cabinet official to discuss President Obama's nuclear security and nonproliferation agenda outside the United States since the President delivered his landmark speech in Prague in April 2009.

  7. Neuroimaging findings in treatment-resistant schizophrenia: a systematic review

    PubMed Central

    Nakajima, Shinichiro; Takeuchi, Hiroyoshi; Plitman, Eric; Fervaha, Gagan; Gerretsen, Philip; Caravaggio, Fernando; Chung, Jun Ku; Iwata, Yusuke; Remington, Gary; Graff-Guerrero, Ariel

    2015-01-01

    Background Recent developments in neuroimaging have advanced understanding biological mechanisms underlying schizophrenia. However, neuroimaging correlates of treatment-resistant schizophrenia (TRS) and superior effects of clozapine on TRS remain unclear. Methods Systematic search was performed to identify neuroimaging characteristics unique to TRS and ultra-resistant schizophrenia (i.e. clozapine-resistant [URS]), and clozapine's efficacy in TRS using Embase, Medline, and PsychInfo. Search terms included (schizophreni*) and (resistan* OR refractory OR clozapine) and (ASL OR CT OR DTI OR FMRI OR MRI OR MRS OR NIRS OR PET OR SPECT). Results 25 neuroimaging studies have investigated TRS and effects of clozapine. Only 5 studies have compared TRS and non-TRS, collectively providing no replicated neuroimaging finding specific to TRS. Studies comparing TRS and healthy controls suggest hypometabolism in the prefrontal cortex, hypermetabolism in the basal ganglia, and structural anomalies in the corpus callosum contribute to TRS. Clozapine may increase prefrontal hypoactivation in TRS although this was not related to clinical improvement; in contrast, evidence has suggested a link between clozapine efficacy and decreased metabolism in the basal ganglia and thalamus. Conclusion Existing literature does not elucidate neuroimaging correlates specific to TRS or URS, which, if present, might also shed light on clozapine's efficacy in TRS. This said, leads from other lines of investigation, including the glutamatergic system can prove useful in guiding future neuroimaging studies focused on, in particular, the frontocortical-basal ganglia-thalamic circuits. Critical to the success of this work will be precise subtyping of study subjects based on treatment response/nonresponse and the use of multimodal neuroimaging. PMID:25684554

  8. Cost-effectiveness analysis of an enteral nutrition protocol for children with common gastrointestinal diseases in China: good start but still a long way to go.

    PubMed

    Yang, Min; Chen, Pei-Yu; Gong, Si-Tang; Lyman, Beth; Geng, Lan-Lan; Liu, Li-Ying; Liang, Cui-Ping; Xu, Zhao-Hui; Li, Hui-Wen; Fang, Tie-Fu; Li, Ding-You

    2014-11-01

    A standard nutrition screening and enteral nutrition (EN) protocol was implemented in January 2012 in a tertiary children's center in China. The aims of the present study were to evaluate the cost-effectiveness of a standard EN protocol in hospitalized patients. A retrospective chart review was performed in the gastroenterology inpatient unit. We included all inpatient children requiring EN from January 1, 2010, to December 31, 2013, with common gastrointestinal (GI) diseases. Children from January 1, 2012, to December 31, 2013, served as the standard EN treatment group, and those from January 1, 2010, to December 31, 2011, were the control EN group. Pertinent patient information was collected. We also analyzed the length of hospital stay, cost of care, and in-hospital infection rates. The standard EN treatment group received more nasojejunal tube feedings. There was a tendency for the standard EN treatment group to receive more elemental and hydrolyzed protein formulas. Implementation of a standard EN protocol significantly reduced the time to initiate EN (32.38 ± 24.50 hours vs 18.76 ± 13.53 hours; P = .011) and the time to reach a targeted calorie goal (7.42 ± 3.98 days vs 5.06 ± 3.55 days; P = .023); length of hospital stay was shortened by 3.2 days after implementation of the standard EN protocol but did not reach statistical significance. However, the shortened length of hospital stay contributed to a significant reduction in the total cost of hospital care (13,164.12 ± 6722.95 Chinese yuan [CNY] vs 9814.96 ± 4592.91 CNY; P < .032). Implementation of a standard EN protocol resulted in early initiation of EN, shortened length of stay, and significantly reduced total cost of care in hospitalized children with common GI diseases. © 2014 American Society for Parenteral and Enteral Nutrition.

  9. Higher Order Aberrations after Femtosecond LASIK Flap Creation

    DTIC Science & Technology

    2016-03-03

    Capt. 59TRS. SGVT (59th CSPG/SGVU) FHW20 14006 1H PROTOCOL TITLE A R etrospect ive Com par ison of H igh er O rder A b errat ions Measured by Pcntacam...55 2. Do nor release r It is doc11111e11r wi r lw11r r lte prior collS l’llf r~/蛆 !SGl.JA. 6. If you have any questions. please call meal 2

  10. Evaluation of BGJ398, a Fibroblast Growth Factor Receptor 1-3 Kinase Inhibitor, in Patients With Advanced Solid Tumors Harboring Genetic Alterations in Fibroblast Growth Factor Receptors: Results of a Global Phase I, Dose-Escalation and Dose-Expansion Study.

    PubMed

    Nogova, Lucia; Sequist, Lecia V; Perez Garcia, Jose Manuel; Andre, Fabrice; Delord, Jean-Pierre; Hidalgo, Manuel; Schellens, Jan H M; Cassier, Philippe A; Camidge, D Ross; Schuler, Martin; Vaishampayan, Ulka; Burris, Howard; Tian, G Gary; Campone, Mario; Wainberg, Zev A; Lim, Wan-Teck; LoRusso, Patricia; Shapiro, Geoffrey I; Parker, Katie; Chen, Xueying; Choudhury, Somesh; Ringeisen, Francois; Graus-Porta, Diana; Porter, Dale; Isaacs, Randi; Buettner, Reinhard; Wolf, Jürgen

    2017-01-10

    Purpose This two-part, first-in-human study was initiated in patients with advanced solid tumors harboring genetic alterations in fibroblast growth factor receptors (FGFRs) to determine the maximum tolerated dose (MTD), the recommended phase II dose (RP2D), and the schedule, safety, pharmacokinetics, pharmacodynamics, and antitumor activity of oral BGJ398, a selective FGFR1-3 tyrosine kinase inhibitor. Patients and Methods Adult patients were treated with escalating dosages of BGJ398 5 to 150 mg once daily or 50 mg twice daily continuously in 28-day cycles. During expansion at the MTD, patients with FGFR1-amplified squamous cell non-small-cell lung cancer (sqNSCLC; arm 1) or other solid tumors with FGFR genetic alterations (mutations/amplifications/fusions) received BGJ398 daily on a continuous schedule (arm 2), or on a 3-weeks-on/1-week-off schedule (arm 3). Results Data in 132 patients from the escalation and expansion arms are reported (May 15, 2015, cutoff). The MTD, 125 mg daily, was determined on the basis of dose-limiting toxicities in four patients (100 mg, grade 3 aminotransferase elevations [n = 1]; 125 mg, hyperphosphatemia [n = 1]; 150 mg, grade 1 corneal toxicity [n = 1] and grade 3 aminotransferase elevations [n = 1]). Common adverse events in patients treated at the MTD (n = 57) included hyperphosphatemia (82.5%), constipation (50.9%), decreased appetite (45.6%), and stomatitis (45.6%). A similar safety profile was observed using the 3-weeks-on/1-week-off schedule (RP2D). However, adverse event-related dose adjustments/interruptions were less frequent with the 3-weeks-on/1-week-off (50.0%) versus the continuous (73.7%) schedule. Antitumor activity (seven partial responses [six confirmed]) was demonstrated with BGJ398 doses ≥ 100 mg in patients with FGFR1-amplified sqNSCLC and FGFR3-mutant bladder/urothelial cancer. Conclusion BGJ398 at the MTD/RP2D had a tolerable and manageable safety profile and showed antitumor activity in several tumor types

  11. Quality of radiotherapy services in post-Soviet countries: An IAEA survey.

    PubMed

    Rosenblatt, Eduardo; Fidarova, Elena; Ghosh, Sunita; Zubizarreta, Eduardo; Unterkirhere, Olga; Semikoz, Natalia; Sinaika, Valery; Kim, Viktor; Karamyan, Nerses; Isayev, Isa; Akbarov, Kamal; Lomidze, Darejan; Bondareva, Oksana; Tuzlucov, Piotr; Zardodkhonova, Manzura; Tkachev, Sergey; Kislyakova, Marina; Alimov, Jamshid; Pidlubna, Tetiana; Barton, Michael; Mackillop, William

    2018-04-25

    The quality of radiotherapy services in post-Soviet countries has not yet been studied following a formal methodology. The IAEA conducted a survey using two sets of validated radiation oncology quality indicators (ROIs). Eleven post-Soviet countries were assessed. A coordinator was designated for each country and acted as the liaison between the country and the IAEA. The methodology was a one-time cross-sectional survey using a 58-question tool in Russian. The questionnaire was based on two validated sets of ROIs: for radiotherapy centres, the indicators proposed by Cionini et al., and for data at the country level, the Australasian ROIs. The overall response ratio was 66.3%, but for the Russian Federation, it was 24%. Data were updated on radiotherapy infrastructure and equipment. 256 radiotherapy centres are operating 275 linear accelerators and 337 Cobalt-60 units. 61% of teletherapy machines are older than ten years. Analysis of ROIs revealed significant differences between these countries and radiotherapy practices in the West. Naming, task profile and education programmes of radiotherapy professionals are different than in the West. Most countries need modernization of their radiotherapy infrastructure coupled with adequate staffing numbers and updated education programmes focusing on evidence-based medicine, quality, and safety. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Elevated Temperature Deformation of Fe-39.8Al and Fe-15.6Mn-39.4Al

    NASA Technical Reports Server (NTRS)

    Whittenberger, J. Daniel

    2004-01-01

    The elevated temperature compressive properties of binary Fe-39.8 at % Al and Fe-15.6Mn-39.4Al have been measured between 1000 and 1300 K at strain rates between 10(exp 7) and 10(exp 3)/ s. Although the Mn addition to iron aluminide did not change the basic deformation characteristics, the Mn-modified alloy was slightly weaker. In the regime where deformation of FeAl occurs by a high stress exponent mechanism (n = 6), strength increases as the grain size decreases at least for diameters between approx. 200 and approx. 10 microns. Due to the limitation in the grain size-flow stress-temperature-strain rate database, the influence of further reductions of the grain size on strength is uncertain. Based on the appearance of subgrains in deformed iron aluminide, the comparison of grain diameters to expected subgrain sizes, and the grain size exponent and stress exponent calculated from deformation experiments, it is believed that grain size strengthening is the result of an artificial limitation on subgrain size as proposed by Sherby, Klundt and Miller.

  13. Towards a tactical nuclear weapons treaty? Is There a Role of IAEA Tools of Safeguards?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, Emily C.; Rowberry, Ariana N.; Fearey, Bryan L.

    2012-07-12

    In recent years, there is growing interest in formal negotiations on non-strategic or tactical nuclear weapons. With the negotiations of New START, there has been much speculation that a tactical nuclear weapons treaty should be included in the follow on to New START. This paper examines the current policy environment related to tactical weapons and some of the issues surrounding the definition of tactical nuclear weapons. We then map out the steps that would need to be taken in order to begin discussions on a tactical nuclear weapons treaty. These steps will review the potential role of the IAEA inmore » verification of a tactical nuclear weapons treaty. Specifically, does IAEA involvement in various arms control treaties serve as a useful roadmap on how to overcome some of the issues pertaining to a tactical nuclear weapons treaty?« less

  14. IAEA coordinated research project on thermal-hydraulics of Supercritical Water-Cooled Reactors (SCWRs)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, K.; Aksan, S. N.

    The Supercritical Water-Cooled Reactor (SCWR) is an innovative water-cooled reactor concept, which uses supercritical pressure water as reactor coolant. It has been attracting interest of many researchers in various countries mainly due to its benefits of high thermal efficiency and simple primary systems, resulting in low capital cost. The IAEA started in 2008 a Coordinated Research Project (CRP) on Thermal-Hydraulics of SCWRs as a forum to foster the exchange of technical information and international collaboration in research and development. This paper summarizes the activities and current status of the CRP, as well as major progress achieved to date. At present,more » 15 institutions closely collaborate in several tasks. Some organizations have been conducting thermal-hydraulics experiments and analysing the data, and others have been participating in code-to-test and/or code-to-code benchmark exercises. The expected outputs of the CRP are also discussed. Finally, the paper introduces several IAEA activities relating to or arising from the CRP. (authors)« less

  15. NGSI student activities in open source information analysis in support of the training program of the U.S. DOE laboratories for the entry into force of the additional protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandoval, M Analisa; Uribe, Eva C; Sandoval, Marisa N

    2009-01-01

    In 2008 a joint team from Los Alamos National Laboratory (LANL) and Brookhaven National Laboratory (BNL) consisting of specialists in training of IAEA inspectors in the use of complementary access activities formulated a training program to prepare the U.S. Doe laboratories for the entry into force of the Additional Protocol. As a major part of the support of the activity, LANL summer interns provided open source information analysis to the LANL-BNL mock inspection team. They were a part of the Next Generation Safeguards Initiative's (NGSI) summer intern program aimed at producing the next generation of safeguards specialists. This paper describesmore » how they used open source information to 'backstop' the LANL-BNL team's effort to construct meaningful Additional Protocol Complementary Access training scenarios for each of the three DOE laboratories, Lawrence Livermore National Laboratory, Idaho National Laboratory, and Oak Ridge National Laboratory.« less

  16. Rapid development of tissue bank achieved by International Atomic Energy Agency (IAEA) Tissue Banking Programme in China.

    PubMed

    Zhang, Yu-Min; Wang, Jian-Ru; Zhang, Nai-Li; Liu, Xiao-Ming; Zhou, Mo; Ma, Shao-Ying; Yang, Ting; Li, Bao-Xing

    2014-09-01

    Before 1986, the development of tissue banking in China has been slow and relatively uncoordinated. Under the support of International Atomic Energy Agency (IAEA), Tissue Banking in China experienced rapid development. In this period, China Institute for Radiation Protection tissue bank mastered systematic and modern tissue banking technique by IAEA training course and gradually developed the first regional tissue bank (Shanxi Provincial Tissue Bank, SPTB) to provide tissue allograft. Benefit from training course, SPTB promoted the development of tissue transplantation by ways of training, brochure, advertisement and meeting. Tissue allograft transplantation acquired recognition from clinic and supervision and administration from government. Quality system gradually is developing and perfecting. Tissue allograft transplantation and tissue bank are developing rapidly and healthy.

  17. [Nuclear energy and environment: review of the IAEA environmental projects].

    PubMed

    Fesenko, S; Fogt, G

    2012-01-01

    The review of the environmental projects of the International Atomic Energy Agency is presented. Basic IAEA documents intended to protect humans and the Environment are considered and their main features are discussed. Some challenging issues in the area of protection of the Environment and man, including the impact of nuclear facilities on the environment, radioactive waste management, and remediation of the areas affected by radiological accidents, nuclear testing and sites of nuclear facilities are also discussed. The need to maintain the existing knowledge in radioecology and protection of the environment is emphasised.

  18. Measurement of ²²⁶Ra in soil from oil field: advantages of γ-ray spectrometry and application to the IAEA-448 CRM.

    PubMed

    Ceccatelli, A; Katona, R; Kis-Benedek, G; Pitois, A

    2014-05-01

    The analytical performance of gamma-ray spectrometry for the measurement of (226)Ra in TENORM (Technically Enhanced Naturally Occurring Radioactive Material) soil was investigated by the IAEA. Fast results were obtained for characterization and certification of a new TENORM Certified Reference Material (CRM), identified as IAEA-448 (soil from oil field). The combined standard uncertainty of the gamma-ray spectrometry results is of the order of 2-3% for massic activity measurement values ranging from 16500 Bq kg(-1) to 21500 Bq kg(-1). Methodologies used for the production and certification of the IAEA-448 CRM are presented. Analytical results were confirmed by alpha spectrometry. The "t" test showed agreement between alpha and gamma results at 95% confidence level. © 2013 Published by Elsevier Ltd.

  19. The evolution and function of protein tandem repeats in plants.

    PubMed

    Schaper, Elke; Anisimova, Maria

    2015-04-01

    Sequence tandem repeats (TRs) are abundant in proteomes across all domains of life. For plants, little is known about their distribution or contribution to protein function. We exhaustively annotated TRs and studied the evolution of TR unit variations for all Ensembl plants. Using phylogenetic patterns of TR units, we detected conserved TRs with unit number and order preserved during evolution, and those TRs that have diverged via recent TR unit gains/losses. We correlated the mode of evolution of TRs to protein function. TR number was strongly correlated with proteome size, with about one-half of all TRs recognized as common protein domains. The majority of TRs have been highly conserved over long evolutionary distances, some since the separation of red algae and green plants c. 1.6 billion yr ago. Conversely, recurrent recent TR unit mutations were rare. Our results suggest that the first TRs by far predate the first plants, and that TR appearance is an ongoing process with similar rates across the plant kingdom. Interestingly, the few detected highly mutable TRs might provide a source of variation for rapid adaptation. In particular, such TRs are enriched in leucine-rich repeats (LRRs) commonly found in R genes, where TR unit gain/loss may facilitate resistance to emerging pathogens. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  20. Papers arising from IAEA Coordinated Research Project "Utilization of ion accelerators for studying and modelling of radiation induced defects in semiconductors and insulators" (F11016)

    NASA Astrophysics Data System (ADS)

    Vittone, Ettore; Breese, Mark; Simon, Aliz

    2016-04-01

    Within the International Atomic Energy Agency (IAEA) Department of Nuclear Sciences and Applications, activities are carried out to assist and advise IAEA Member States in assessing their needs for capacity building, research and development in nuclear sciences. Support is also provided to Member States' activities geared towards deriving benefits in fields such as (i) advanced materials for nuclear applications, (ii) application of accelerators and associated instrumentation, and (iii) nuclear, atomic and molecular data. One of the means that the IAEA uses to deliver its programme is Coordinated Research Projects (CRPs) which are very effective in stimulating international research and scientific interaction among the Member States.

  1. TU-AB-BRC-07: Efficiency of An IAEA Phase-Space Source for a Low Energy X-Ray Tube Using Egs++

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watson, PGF; Renaud, MA; Seuntjens, J

    Purpose: To extend the capability of the EGSnrc C++ class library (egs++) to write and read IAEA phase-space files as a particle source, and to assess the relative efficiency gain in dose calculation using an IAEA phase-space source for modelling a miniature low energy x-ray source. Methods: We created a new ausgab object to score particles exiting a user-defined geometry and write them to an IAEA phase-space file. A new particle source was created to read from IAEA phase-space data. With these tools, a phase-space file was generated for particles exiting a miniature 50 kVp x-ray tube (The INTRABEAM System,more » Carl Zeiss). The phase-space source was validated by comparing calculated PDDs with a full electron source simulation of the INTRABEAM. The dose calculation efficiency gain of the phase-space source was determined relative to the full simulation. The efficiency gain as a function of i) depth in water, and ii) job parallelization was investigated. Results: The phase-space and electron source PDDs were found to agree to 0.5% RMS, comparable to statistical uncertainties. The use of a phase-space source for the INTRABEAM led to a relative efficiency gain of greater than 20 over the full electron source simulation, with an increase of up to a factor of 196. The efficiency gain was found to decrease with depth in water, due to the influence of scattering. Job parallelization (across 2 to 256 cores) was not found to have any detrimental effect on efficiency gain. Conclusion: A set of tools has been developed for writing and reading IAEA phase-space files, which can be used with any egs++ user code. For simulation of a low energy x-ray tube, the use of a phase-space source was found to increase the relative dose calculation efficiency by factor of up to 196. The authors acknowledge partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant No. 432290).« less

  2. The NASA Scientific and Technical Information (STI) Program's Implementation of Open Archives Initiation (OAI) for Data Interoperability and Data Exchange

    NASA Technical Reports Server (NTRS)

    Rocker, JoAnne; Roncaglia, George J.; Heimerl, Lynn N.; Nelson, Michael L.

    2002-01-01

    Interoperability and data-exchange are critical for the survival of government information management programs. E-government initiatives are transforming the way the government interacts with the public. More information is to be made available through web-enabled technologies. Programs such as the NASA's Scientific and Technical Information (STI) Program Office are tasked to find more effective ways to disseminate information to the public. The NASA STI Program is an agency-wide program charged with gathering, organizing, storing, and disseminating NASA-produced information for research and public use. The program is investigating the use of a new protocol called the Open Archives Initiative (OAI) as a means to improve data interoperability and data collection. OAI promotes the use of the OAI harvesting protocol as a simple way for data sharing among repositories. In two separate initiatives, the STI Program is implementing OAI In collaboration with the Air Force, Department of Energy, and Old Dominion University, the NASA STI Program has funded research on implementing the OAI to exchange data between the three organizations. The second initiative is the deployment of OAI for the NASA technical report server (TRS) environment. The NASA TRS environment is comprised of distributed technical report servers with a centralized search interface. This paper focuses on the implementation of OAI to promote interoperability among diverse data repositories.

  3. Characterization of Livestock-Associated Methicillin-Resistant Staphylococcus aureus CC398 and mecC-positive CC130 from Zoo Animals in the United Kingdom.

    PubMed

    Bortolami, Alessio; Verin, Ranieri; Chantrey, Julian; Corrò, Michela; Ashpole, Ian; Lopez, Javier; Timofte, Dorina

    2017-10-01

    Little is known about the characteristics and diseases associated with methicillin-resistant Staphylococcus aureus (MRSA) in nondomestic animals. Four presumptive MRSA isolates, obtained from clinical (n = 3) and surveillance specimens (n = 1) from dwarf (Helogale parvula) and yellow mongooses (Cynictis penicillata) from a United Kingdom zoo, were analyzed by PCR for detection of mecA and mecC-mediated methicillin resistance, and virulence genes. Isolates were genotyped by multilocus sequence typing (MLST) and staphylococcal cassette chromosome mec (SCCmec) and spa sequence typing. Three isolates, obtained from the dwarf mongooses, carried mecA, tetK, and fexA resistance and virulence genes (icaA, icaD, and sec) and were typed to SCCmec IVa, spa type t899, and clonal complex (CC) 398. The fourth MRSA isolate, obtained from the femoral bone marrow of a yellow mongoose showing postmortem findings consistent with septicemia, carried mecC and was oxacillin/cefoxitin susceptible, when tested at 37°C but showed a characteristic MRSA susceptibility profile at 25°C ± 2°C. Furthermore, this isolate exhibited a different genetic background (SCCmecXI/t843/CC130) and had biofilm-associated genes (bap, icaA, and icaD) and tetK tetracycline resistance genes. This work describes the first isolation of livestock-associated MRSA CC398 from two zoo mongoose species where it was associated with both clinical disease and colonization, and the first isolation of mecC MRSA from a zoo species in the United Kingdom. Both reports highlight the potential for zoo species to act as reservoirs for these zoonotic agents.

  4. Seabed gamma-ray spectrometry: applications at IAEA-MEL.

    PubMed

    Osvath, I; Povinec, P P

    2001-01-01

    The technique of underwater gamma-ray spectrometry has been developed to complement or replace the traditional sampling-sample analysis approach for applications with space-time constraints, e.g. large areas of investigation, emergency response or long-term monitoring. IAEA-MEL has used both high-efficiency NaI(Tl) and high-resolution HPGe spectrometry to investigate contamination with anthropogenic radionuclides in a variety of marine environments. Surveys at the South Pacific nuclear test sites of Mururoa and Fangataufa have been used to guide sampling in areas of high contamination around ground zero points. In the Irish Sea offshore from the Sellafield nuclear reprocessing plant, a gamma-ray survey of seabed sediment was carried out to obtain estimates of the distribution and subsequently, for the inventory of 137Cs in the investigated area.

  5. International Conference on Advances in Radiation Oncology (ICARO): outcomes of an IAEA meeting.

    PubMed

    Salminen, Eeva K; Kiel, Krystyna; Ibbott, Geoffrey S; Joiner, Michael C; Rosenblatt, Eduardo; Zubizarreta, Eduardo; Wondergem, Jan; Meghzifene, Ahmed

    2011-02-04

    The IAEA held the International Conference on Advances in Radiation Oncology (ICARO) in Vienna on 27-29 April 2009. The Conference dealt with the issues and requirements posed by the transition from conventional radiotherapy to advanced modern technologies, including staffing, training, treatment planning and delivery, quality assurance (QA) and the optimal use of available resources. The current role of advanced technologies (defined as 3-dimensional and/or image guided treatment with photons or particles) in current clinical practice and future scenarios were discussed.ICARO was organized by the IAEA at the request of the Member States and co-sponsored and supported by other international organizations to assess advances in technologies in radiation oncology in the face of economic challenges that most countries confront. Participants submitted research contributions, which were reviewed by a scientific committee and presented via 46 lectures and 103 posters. There were 327 participants from 70 Member States as well as participants from industry and government. The ICARO meeting provided an independent forum for the interaction of participants from developed and developing countries on current and developing issues related to radiation oncology.

  6. CT protocol management: simplifying the process by using a master protocol concept.

    PubMed

    Szczykutowicz, Timothy P; Bour, Robert K; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N

    2015-07-08

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two-tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade-offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be

  7. CT protocol management: simplifying the process by using a master protocol concept

    PubMed Central

    Bour, Robert K.; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N.

    2015-01-01

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two‐tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade‐offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be

  8. Characterization of staphylococci in urban wastewater treatment plants in Spain, with detection of methicillin resistant Staphylococcus aureus ST398.

    PubMed

    Gómez, Paula; Lozano, Carmen; Benito, Daniel; Estepa, Vanesa; Tenorio, Carmen; Zarazaga, Myriam; Torres, Carmen

    2016-05-01

    The objective of this study was to determine the prevalence of Staphylococcus in urban wastewater treatment plants (UWTP) of La Rioja (Spain), and to characterize de obtained isolates. 16 wastewater samples (8 influent, 8 effluent) of six UWTPs were seeded on mannitol-salt-agar and oxacillin-resistance-screening-agar-base for staphylococci and methicillin-resistant Staphylococcus aureus recovery. Antimicrobial susceptibility profile was determined for 16 antibiotics and the presence of 35 antimicrobial resistance genes and 14 virulence genes by PCR. S. aureus was typed by spa, agr, and multilocus-sequence-typing, and the presence of immune-evasion-genes cluster was analyzed. Staphylococcus spp. were detected in 13 of 16 tested wastewater samples (81%), although the number of CFU/mL decreased after treatment. 40 staphylococci were recovered (1-5/sample), and 8 of them were identified as S. aureus being typed as (number of strains): spa-t011/agr-II/ST398 (1), spa-t002/agr-II/ST5 (2), spa-t3262/agr-II/ST5 (1), spa-t605/agr-II/ST126 (3), and spa-t878/agr-III/ST2849 (1). S. aureus ST398 strain was methicillin-resistant and showed a multidrug resistance phenotype. Virulence genes tst, etd, sea, sec, seg, sei, sem, sen, seo, and seu, were detected among S. aureus and only ST5 strains showed genes of immune evasion cluster. Thirty-two coagulase-negative Staphylococcus of 12 different species were recovered (number of strains): Staphylococcus equorum (7), Staphylococcus vitulinus (4), Staphylococcus lentus (4), Staphylococcus sciuri (4), Staphylococcus fleurettii (2), Staphylococcus haemolyticus (2), Staphylococcus hominis (2), Staphylococcus saprophyticus (2), Staphylococcus succinus (2), Staphylococcus capitis (1), Staphylococcus cohnii (1), and Staphylococcus epidermidis (1). Five presented a multidrug resistance phenotype. The following resistance and virulence genes were found: mecA, lnu(A), vga(A), tet(K), erm(C), msr(A)/(B), mph(C), tst, and sem. We found that

  9. Radiation processing techniques in remediation of pollutants, and the role of the IAEA in supporting capacity building in developing countries

    NASA Astrophysics Data System (ADS)

    Haji-Saeid, S. Mohammad.; Sampa, M. H.; Safrany, A.; Sabharwal, S.; Ramamoorthy, N.

    2012-08-01

    Radiation treatment, or a combination of radiation with conventional biological-chemical-physical processes, can help in the remediation of contaminated surfaces and in combating industrial chemical effluents and air pollution. The use of ionizing radiation as a powerful tool for inactivation of microbes is a valuable option to address likely threats from biohazard contamination that could be introduced either deliberately or inadvertently into areas where the public are exposed to, as well as for treatment of volatile organic compounds and similar hazardous chemical agents is an emerging development in tackling harmful pollutants. The role of the IAEA has been crucial both in supporting the development of local capabilities as well as in fostering international cooperation due to the multidisciplinary expertise required for achieving sustainable benefits. The IAEA is implementing Coordinated Research Projects, (CRP) thematic topical reviews of issues and challenges involved, and Technical Cooperation (TC) assistance in establishing and maintaining infrastructure in the MS. This paper will give an insight into the above mentioned IAEA activities, with examples of successes achieved through CRPs, as well as challenges on the road for broader dissemination of radiation processing technology for environmental remediation.

  10. Hybrid imaging worldwide-challenges and opportunities for the developing world: a report of a Technical Meeting organized by IAEA.

    PubMed

    Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Mariani, Guliano

    2013-05-01

    The growth in nuclear medicine, in the past decade, is largely due to hybrid imaging, specifically single-photon emission tomography-computed tomography (SPECT-CT) and positron emission tomography-computed tomography (PET-CT). Introduction and use of hybrid imaging has been growing at a fast pace. This has led to many challenges and opportunities to the personnel dealing with it. The International Atomic Energy Agency (IAEA) keeps a close watch on the trends in applications of nuclear techniques in health by many ways, including obtaining inputs from member states and professional societies. In 2012, a Technical Meeting on trends in hybrid imaging was organized by IAEA to understand the current status and trends of hybrid imaging using nuclear techniques, its role in clinical practice, and associated educational needs and challenges. Perspective of scientific societies and professionals from all the regions of the world was obtained. Heterogeneity in value, educational needs, and access was noted and the drivers of this heterogeneity were discussed. This article presents the key points shared during the technical meeting, focusing primarily on SPECT-CT and PET-CT, and shares the action plan for IAEA to deal with heterogeneity as suggested by the participants. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Do unliganded thyroid hormone receptors have physiological functions?

    PubMed

    Chassande, O

    2003-08-01

    Thyroid hormone (TH) is required for the development of vertebrates and exerts numerous homeostatic functions in adults. TH acts through nuclear receptors which control the transcription of target genes. Unliganded and liganded thyroid hormone receptors (TRs) have been shown to exert opposite effects on the transcription of target genes in vitro. However, the occurance of an aporeceptor activity in vivo and its potential physiological significance has not been clearly addressed. Several data generated using experimental hypothyroidism and thyrotoxicosis in wild type and TR knockout mice support the notion that apoTRs have an intrinsic activity in several tIssues. ApoTRs, and in particular TRalpha1, are predominant during the early stages of vertebrate development and must be turned into holoTRs for post-natal development to proceed normally. However, the absence of striking alterations of embryonic and fetal development in mice devoid of TRs indicates that apoTRs do not play a fundamental role. During development, as well as in adults, apoTRs rather appears as a system which increases the range of transcriptional responses to moderate variations of T3.

  12. Analyzing the effect of routing protocols on media access control protocols in radio networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, C. L.; Drozda, M.; Marathe, A.

    2002-01-01

    We study the effect of routing protocols on the performance of media access control (MAC) protocols in wireless radio networks. Three well known MAC protocols: 802.11, CSMA, and MACA are considered. Similarly three recently proposed routing protocols: AODV, DSR and LAR scheme 1 are considered. The experimental analysis was carried out using GloMoSim: a tool for simulating wireless networks. The main focus of our experiments was to study how the routing protocols affect the performance of the MAC protocols when the underlying network and traffic parameters are varied. The performance of the protocols was measured w.r.t. five important parameters: (i)more » number of received packets, (ii) average latency of each packet, (iii) throughput (iv) long term fairness and (v) number of control packets at the MAC layer level. Our results show that combinations of routing and MAC protocols yield varying performance under varying network topology and traffic situations. The result has an important implication; no combination of routing protocol and MAC protocol is the best over all situations. Also, the performance analysis of protocols at a given level in the protocol stack needs to be studied not locally in isolation but as a part of the complete protocol stack. A novel aspect of our work is the use of statistical technique, ANOVA (Analysis of Variance) to characterize the effect of routing protocols on MAC protocols. This technique is of independent interest and can be utilized in several other simulation and empirical studies.« less

  13. Dosimetric inter-institutional comparison in European radiotherapy centres: Results of IAEA supported treatment planning system audit.

    PubMed

    Gershkevitsh, Eduard; Pesznyak, Csilla; Petrovic, Borislava; Grezdo, Joseph; Chelminski, Krzysztof; do Carmo Lopes, Maria; Izewska, Joanna; Van Dyk, Jacob

    2014-05-01

    One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries - Estonia, Hungary, Latvia, Lithuania, Serbia, Slovakia, Poland and Portugal. The corresponding results are presented. The TPS audit reviews the dosimetry, treatment planning and radiotherapy delivery processes using the 'end-to-end' approach, i.e. following the pathway similar to that of the patient, through imaging, treatment planning and dose delivery. The audit is implemented at the national level with IAEA assistance. The national counterparts conduct the TPS audit at local radiotherapy centres through on-site visits. TPS calculated doses are compared with ion chamber measurements performed in an anthropomorphic phantom for eight test cases per algorithm/beam. A set of pre-defined agreement criteria is used to analyse the performance of TPSs. TPS audit was carried out in 60 radiotherapy centres. In total, 190 data sets (combination of algorithm and beam quality) have been collected and reviewed. Dosimetry problems requiring interventions were discovered in about 10% of datasets. In addition, suboptimal beam modelling in TPSs was discovered in a number of cases. The TPS audit project using the IAEA methodology has verified the treatment planning system calculations for 3D conformal radiotherapy in a group of radiotherapy centres in Europe. It contributed to achieving better understanding of the performance of TPSs and helped to resolve issues related to imaging, dosimetry and treatment planning.

  14. R-Matrix Codes for Charged-Particle Induced Reactions in the Resolved Resonance Region (3), Summary Report of an IAEA Consultants' Meeting IAEA Headquarters, Vienna, Austria, 28-30 June 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leeb, Helmut; Dimitriou, Paraskevi; Thompson, Ian

    A Consultants Meeting was held at the IAEA Headquarters, from 28 to 30 June 2017, to discuss the results of a test exercise that had been defined and assigned to all participants of the previous meeting held in December 2016. Five codes were used in this exercise: AMUR, AZURE2, RAC, SFRESCO and SAMMY. The results obtained from these codes were compared and further actions were proposed. Participants’ presentations and technical discussions, as well as proposed additional actions have been summarized in this report.

  15. Approach to training of personnel to manage radioactive wastes offered by education training Centre at Moscow Sia Radon under sponsorship of IAEA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batyukhnova, O.G.; Dmitriev, S.A.; Ojovan, M.I.

    The availability of qualified personnel is crucial to the licensing and efficient and safe operation of waste management facilities and for the improvement of the existing waste management practices. The countries with some degree of waste management activities are of special concerns, since their narrow waste management experience and personal capabilities may be a limiting factor to manage radioactive waste in a safe and technically optimal manner. The International Education Training Centre (IETC) at Moscow State Unitary Enterprise Scientific and Industrial Association 'Radon' (SIA 'Radon'), in co-operation with the International Atomic Energy Agency (IAEA), has developed expertise and provided trainingmore » to waste management personnel for the last 10 years. During this period, more than 300 specialists from 26 European and Asian countries, (mostly) sponsored by the IAEA, have increased their knowledge and skills in radioactive waste management. The current experience of the SIA 'Radon' in the organisation of the IAEA sponsored training is summarized and an outline of some strategic educational elements, which IETC will continue to pursue in the coming years, is provided. (authors)« less

  16. Evaluation of dose from kV cone-beam computed tomography during radiotherapy: a comparison of methodologies

    NASA Astrophysics Data System (ADS)

    Buckley, J.; Wilkinson, D.; Malaroda, A.; Metcalfe, P.

    2017-01-01

    Three alternative methodologies to the Computed-Tomography Dose Index for the evaluation of Cone-Beam Computed Tomography dose are compared, the Cone-Beam Dose Index, IAEA Human Health Report No. 5 recommended methodology and the AAPM Task Group 111 recommended methodology. The protocols were evaluated for Pelvis and Thorax scan modes on Varian® On-Board Imager and Truebeam kV XI imaging systems. The weighted planar average dose was highest for the AAPM methodology across all scans, with the CBDI being the second highest overall. A 17.96% and 1.14% decrease from the TG-111 protocol to the IAEA and CBDI protocols for the Pelvis mode and 18.15% and 13.10% decrease for the Thorax mode were observed for the XI system. For the OBI system, the variation was 16.46% and 7.14% for Pelvis mode and 15.93% to the CBDI protocol in Thorax mode respectively.

  17. TRStalker: an efficient heuristic for finding fuzzy tandem repeats.

    PubMed

    Pellegrini, Marco; Renda, M Elena; Vecchio, Alessio

    2010-06-15

    Genomes in higher eukaryotic organisms contain a substantial amount of repeated sequences. Tandem Repeats (TRs) constitute a large class of repetitive sequences that are originated via phenomena such as replication slippage and are characterized by close spatial contiguity. They play an important role in several molecular regulatory mechanisms, and also in several diseases (e.g. in the group of trinucleotide repeat disorders). While for TRs with a low or medium level of divergence the current methods are rather effective, the problem of detecting TRs with higher divergence (fuzzy TRs) is still open. The detection of fuzzy TRs is propaedeutic to enriching our view of their role in regulatory mechanisms and diseases. Fuzzy TRs are also important as tools to shed light on the evolutionary history of the genome, where higher divergence correlates with more remote duplication events. We have developed an algorithm (christened TRStalker) with the aim of detecting efficiently TRs that are hard to detect because of their inherent fuzziness, due to high levels of base substitutions, insertions and deletions. To attain this goal, we developed heuristics to solve a Steiner version of the problem for which the fuzziness is measured with respect to a motif string not necessarily present in the input string. This problem is akin to the 'generalized median string' that is known to be an NP-hard problem. Experiments with both synthetic and biological sequences demonstrate that our method performs better than current state of the art for fuzzy TRs and that the fuzzy TRs of the type we detect are indeed present in important biological sequences. TRStalker will be integrated in the web-based TRs Discovery Service (TReaDS) at bioalgo.iit.cnr.it. Supplementary data are available at Bioinformatics online.

  18. A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin

    PubMed Central

    Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim

    2015-01-01

    Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511

  19. Alternative parallel ring protocols

    NASA Technical Reports Server (NTRS)

    Mukkamala, R.; Foudriat, E. C.; Maly, Kurt J.; Kale, V.

    1990-01-01

    Communication protocols are know to influence the utilization and performance of communication network. The effect of two token ring protocols on a gigabit network with multiple ring structure is investigated. In the first protocol, a mode sends at most one message on receiving a token. In the second protocol, a mode sends all the waiting messages when a token is received. The behavior of these protocols is shown to be highly dependent on the number of rings as well as the load in the network.

  20. Communications protocol

    NASA Technical Reports Server (NTRS)

    Zhou, Xiaoming (Inventor); Baras, John S. (Inventor)

    2010-01-01

    The present invention relates to an improved communications protocol which increases the efficiency of transmission in return channels on a multi-channel slotted Alohas system by incorporating advanced error correction algorithms, selective retransmission protocols and the use of reserved channels to satisfy the retransmission requests.

  1. Radiation processing of natural polymers: The IAEA contribution

    NASA Astrophysics Data System (ADS)

    Haji-Saeid, Mohammad; Safrany, Agnes; Sampa, Maria Helena de O.; Ramamoorthy, Natesan

    2010-03-01

    Radiation processing offers a clean and additive-free method for preparation of value-added novel materials based on renewable, non-toxic, and biodegradable natural polymers. Crosslinked natural polymers can be used as hydrogel wound dressings, face cleaning cosmetic masks, adsorbents of toxins, and non-bedsore mats; while low molecular weight products show antibiotic, antioxidant, and plant-growth promoting properties. Recognizing the potential benefits that radiation technology can offer for processing of natural polymers into useful products, the IAEA implemented a coordinated research project (CRP) on "Development of Radiation-processed products of Natural Polymers for application in Agriculture, Healthcare, Industry and Environment". This CRP was launched at the end of 2007 with participation of 16 MS to help connecting radiation technology and end-users to derive enhanced benefits from these new value-added products of radiation-processed natural materials. In this paper the results of activities in participating MS related to this work will be presented.

  2. Reliable broadcast protocols

    NASA Technical Reports Server (NTRS)

    Joseph, T. A.; Birman, Kenneth P.

    1989-01-01

    A number of broadcast protocols that are reliable subject to a variety of ordering and delivery guarantees are considered. Developing applications that are distributed over a number of sites and/or must tolerate the failures of some of them becomes a considerably simpler task when such protocols are available for communication. Without such protocols the kinds of distributed applications that can reasonably be built will have a very limited scope. As the trend towards distribution and decentralization continues, it will not be surprising if reliable broadcast protocols have the same role in distributed operating systems of the future that message passing mechanisms have in the operating systems of today. On the other hand, the problems of engineering such a system remain large. For example, deciding which protocol is the most appropriate to use in a certain situation or how to balance the latency-communication-storage costs is not an easy question.

  3. 47 CFR 64.623 - Administrator requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... administrator of the TRS User Registration Database, the administrator of the VRS Access Technology Reference... parties with a vested interest in the outcome of TRS-related numbering administration and activities. (4) None of the administrator of the TRS User Registration Database, the administrator of the VRS Access...

  4. 47 CFR 64.623 - Administrator requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... administrator of the TRS User Registration Database, the administrator of the VRS Access Technology Reference... parties with a vested interest in the outcome of TRS-related numbering administration and activities. (4) None of the administrator of the TRS User Registration Database, the administrator of the VRS Access...

  5. Automating Security Protocol Analysis

    DTIC Science & Technology

    2004-03-01

    language that allows easy representation of pattern interaction. Using CSP, Lowe tests whether a protocol achieves authentication. In the case of...only to correctly code whatever protocol they intend to evaluate. The tool, OCaml 3.04 [1], translates the protocol into Horn clauses and then...model protocol transactions. One example of automated modeling software is Maude [19]. Maude was the intended language for this research, but Java

  6. WE-AB-213-04: IAEA Support to Medical Physics in Africa and Latin America: Achievements and Challenges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meghzifene, A.

    AAPM projects and collaborations in Africa Adam Shulman (AA-SC Chair) The African Affairs Subcommittee (AA-SC) of the AAPM will present a multi-institutional approach to medical physics support in Africa. Current work to increase the quality of care and level of safety for the medical physics practice in Senegal, Ghana, and Zimbabwe will be presented, along with preliminary projects in Nigeria and Botswana. Because the task of addressing the needs of medical physics in countries across Africa is larger than one entity can accomplish on its own, the AA-SC has taken the approach of joining forces with multiple organizations such asmore » Radiating Hope and TreatSafely (NGO’s), the IAEA, companies like BrainLab, Varian and Elekta, medical volunteers and academic institutions such as NYU and Washington University. Elements of current projects include: 1) Distance training and evaluation of the quality of contouring and treatment planning, teaching treatment planning and other subjects, and troubleshooting using modern telecommunications technology in Senegal, Ghana, and Zimbabwe; 2) Assistance in the transition from 2D to 3D in Senegal and Zimbabwe; 3) Assistance in the transition from 3D to IMRT using in-house compensators in Senegal; 4) Modernizing the cancer center in Senegal and increasing safety and; 5) Training on on 3D techniques in Ghana; 6) Assisting a teaching and training radiation oncology center to be built in Zimbabwe; 7) Working with the ISEP Program in Sub-Saharan Africa; 8) Creating instructional videos on linac commissioning; 9) Working on a possible collaboration to train physicists in Nigeria. Building on past achievements, the subcommittee seeks to make a larger impact on the continent, as the number and size of projects increases and more human resources become available. The State of Medical Physics Collaborations and Projects in Latin America Sandra Guzman (Peru) The lack of Medical Physicists (MP) in many Latin American (LA) countries leads

  7. DDN (Defense Data Network) Protocol Handbook. Volume 1. DoD Military Standard Protocols

    DTIC Science & Technology

    1985-12-01

    official Military Standard communication protocols in use on the DDN are included, as are several ARPANET (Advanced Research Projects Agency Network... research protocols which are currently in use, and some protocols currently undergoing review. Tutorial information and auxiliary documents are also...compatible with DoD needs, by researchers wishing to improve the protocols, and by impleroentors of local area networks (LANs) wishing their

  8. Influence of Psychosocial Factors and Habitual Behavior in Temporomandibular Disorder–Related Symptoms in a Working Population in Japan

    PubMed Central

    Nishiyama, Akira; Kino, Koji; Sugisaki, Masashi; Tsukagoshi, Kaori

    2012-01-01

    Background: The symptoms of temporomandibular disorders (TMD) are directly influenced by numerous factors, and it is thought that additional factors exert indirect influences. However, the relationships between TMD-related symptoms (TRS) and these contributing factors are largely unknown. Thus, the goal of the present study was to investigate influences on TRS in a working population by determining the prevalence of TRS, analyzing contributing factors, and determining their relative influences on TRS. Materials and Methods: The study subjects were 2203 adults who worked for a single company. Subjects completed a questionnaire assessing TRS, psychosocial factors (stress, anxiety, depressed mood, and chronic fatigue), tooth-contacting habit, and sleep bruxism-related morning symptoms, using a 5-point numeric rating scale. Our analysis proceeded in 2 phases. First, all variables of the descriptor were divided into parts by using an exploratory factor analysis. Second, this factorial structure was verified by using a confirmatory factor analysis with structural equation modeling. Results: Of 2203 employees, 362 reported experiencing TRS (16.4%). Structural equation modeling generated a final model with a goodness of fit index of 0.991, an adjusted goodness of fit index of 0.984, and a root mean square error of approximately 0.021. These indices indicate a strong structural model. The standardized path coefficients for “habitual behavioral factors and TRS,” “psychosocial factors and habitual behavioral factors,” “psychosocial factors and TRS,” and “gender and habitual behavior factors” were 0.48, 0.38, 0.14, and 0.18, respectively. Conclusions: Habitual behavioral factors exert a stronger effect on TRS than do psychosocial factors. PMID:23346261

  9. Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B. R.; Rogers, D. W. O.

    2010-11-15

    Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to amore » small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo

  10. Efficient decentralized consensus protocols

    NASA Technical Reports Server (NTRS)

    Lakshman, T. V.; Agrawala, A. K.

    1986-01-01

    Decentralized consensus protocols are characterized by successive rounds of message interchanges. Protocols which achieve a consensus in one round of message interchange require O(N-squared) messages, where N is the number of participants. In this paper, a communication scheme, based on finite projective planes, which requires only O(N sq rt N) messages for each round is presented. Using this communication scheme, decentralized consensus protocols which achieve a consensus within two rounds of message interchange are developed. The protocols are symmetric, and the communication scheme does not impose any hierarchical structure. The scheme is illustrated using blocking and nonblocking commit protocols, decentralized extrema finding, and computation of the sum function.

  11. 31 CFR 321.22 - Forwarding securities not payable by an agent.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... must follow. These instructions are available from a TRS Site or online at www.treasurydirect.gov. [77... TRS Site. The requests for payment on the securities should be properly certified. Any documentary... TRS Site in accordance with the rules in this part. The Bureau of the Fiscal Service provides agents...

  12. 47 CFR 64.5110 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... disclosing CPNI based on a customer-initiated telephone contact, TRS call, point-to-point call, online...) of this section. (c) Online access to CPNI. A TRS provider shall authenticate a customer without the... customer online access to CPNI related to his or her TRS account. Once authenticated, the customer may only...

  13. 47 CFR 64.5110 - Safeguards on the disclosure of customer proprietary network information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... disclosing CPNI based on a customer-initiated telephone contact, TRS call, point-to-point call, online...) of this section. (c) Online access to CPNI. A TRS provider shall authenticate a customer without the... customer online access to CPNI related to his or her TRS account. Once authenticated, the customer may only...

  14. Three dysconnectivity patterns in treatment-resistant schizophrenia patients and their unaffected siblings.

    PubMed

    Wang, Jicai; Cao, Hongbao; Liao, Yanhui; Liu, Weiqing; Tan, Liwen; Tang, Yanqing; Chen, Jindong; Xu, Xiufeng; Li, Haijun; Luo, Chunrong; Liu, Chunyu; Ries Merikangas, Kathleen; Calhoun, Vince; Tang, Jinsong; Shugart, Yin Yao; Chen, Xiaogang

    2015-01-01

    Among individuals diagnosed with schizophrenia, approximately 20%-33% are recognized as treatment-resistant schizophrenia (TRS) patients. These TRS patients suffer more severely from the disease but struggle to benefit from existing antipsychotic treatments. A few recent studies suggested that schizophrenia may be caused by impaired synaptic plasticity that manifests as functional dysconnectivity in the brain, however, few of those studies focused on the functional connectivity changes in the brains of TRS groups. In this study, we compared the whole brain connectivity variations in TRS patients, their unaffected siblings, and healthy controls. Connectivity network features between and within the 116 automated anatomical labeling (AAL) brain regions were calculated and compared using maps created with three contrasts: patient vs. control, patient vs. sibling, and sibling vs. To evaluate the predictive power of the selected features, we performed a multivariate classification approach. We also evaluated the influence of six important clinical measures (e.g. age, education level) on the connectivity features. This study identified abnormal significant connectivity changes of three patterns in TRS patients and their unaffected siblings: 1) 69 patient-specific connectivity (PCN); 2) 102 shared connectivity (SCN); and 3) 457 unshared connectivity (UCN). While the first two patterns were widely reported by previous non-TRS specific studies, we were among the first to report widespread significant connectivity differences between TRS patient groups and their healthy sibling groups. Observations of this study may provide new insights for the understanding of the neurophysiological mechanisms of TRS.

  15. Regional Seminars to Address Current Nuclear Export Control Issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killinger, Mark H.

    2002-07-01

    The control of nuclear-related exports, a critical component of the nonproliferation regime, is facing several opportunities and challenges. As countries sign and ratify the International Atomic Energy Agency's (IAEA) safeguards Additional Protocol (AP), they will begin to report far more export information, including exports of a list of items similar to the Nuclear Supplier Group's Trigger List that existed when the AP was developed in the mid-1990s. This positive development contrasts with challenges such as globalization, transshipments, and tracking of end-uses. Pacific Northwest National Laboratory is proposing that the US Department of Energy (DOE) develop regional seminars that address thesemore » types of issues related to export/import controls. The DOE seminars would be designed to supplement regional seminars sponsored by the IAEA and member states on topics related to the Additional Protocol (referred to as "IAEA seminars"). The topic of nuclear export/import controls is not thoroughly addressed in the IAEA seminars. The proposed DOE seminars would therefore have two objectives: familiarizing countries with the export/import provisions of the Additional Protocol, and addressing challenges such as those noted above. The seminars would be directed particularly at countries that have not ratified the AP, and at regions where export-related problems are particularly prevalent. The intent is to encourage governments to implement more effective nuclear export control systems that meet the challenges of the 21st century.« less

  16. Satellite Communications Using Commercial Protocols

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.; Griner, James H.; Dimond, Robert; Frantz, Brian D.; Kachmar, Brian; Shell, Dan

    2000-01-01

    NASA Glenn Research Center has been working with industry, academia, and other government agencies in assessing commercial communications protocols for satellite and space-based applications. In addition, NASA Glenn has been developing and advocating new satellite-friendly modifications to existing communications protocol standards. This paper summarizes recent research into the applicability of various commercial standard protocols for use over satellite and space- based communications networks as well as expectations for future protocol development. It serves as a reference point from which the detailed work can be readily accessed. Areas that will be addressed include asynchronous-transfer-mode quality of service; completed and ongoing work of the Internet Engineering Task Force; data-link-layer protocol development for unidirectional link routing; and protocols for aeronautical applications, including mobile Internet protocol routing for wireless/mobile hosts and the aeronautical telecommunications network protocol.

  17. [Application of target restoration space quantity and quantitative relation in precise esthetic prosthodontics].

    PubMed

    Haiyang, Yu; Tian, Luo

    2016-06-01

    Target restoration space (TRS) is the most precise space required for designing optimal prosthesis. TRS consists of an internal or external tooth space to confirm the esthetics and function of the final restoration. Therefore, assisted with quantitive analysis transfer, TRS quantitative analysis is a significant improvement for minimum tooth preparation. This article presents TRS quantity-related measurement, analysis, transfer, and internal relevance of three TR. classifications. Results reveal the close bond between precision and minimally invasive treatment. This study can be used to improve the comprehension and execution of precise esthetic prosthodontics.

  18. Mentoring for Success in Tobacco Regulatory Science: A Qualitative Study

    PubMed Central

    Russo, Abigail R.; Solis, Amy C.; Villanti, Andrea C.; Wipfli, Heather L.; Kern, Teresa T.; Lawley, Rachel K.; Collins, Lauren K.; Abudayyeh, Haneen S.; Chansky, Melanie C.; Glantz, Stanton A.; Samet, Jonathan M.; Benjamin, Emelia J.

    2017-01-01

    Objectives Our study explores the experiences of early career and senior scientists regarding mentorship and career trajectories in tobacco regulatory science (TRS). Methods We conducted 22 phone interviews with early career and senior tobacco regulatory scientists from July 2015 to January 2016. All interviews were conducted using a structured interview guide and analyzed using a thematic approach by 2 independent coders. Results TRS presents specific opportunities and challenges to scientists due to its focused goal of informing tobacco regulation. An understanding of US Food and Drug Administration (FDA) research priorities and how science can inform tobacco regulation are essential for effective mentorship in TRS. Careers in TRS can be pursued in various academic and non-academic professional roles; both offer the distinct ability to conduct science that impacts public policy. Early career and senior scientists identified the importance and challenge of providing broad training across the diverse disciplines of TRS. Conclusions Effective mentorship in TRS requires that mentors possess an in-depth understanding of the scientific, regulatory, and legislative processes inherent to tobacco regulatory policy-making. A training program for mentors specific to TRS has the potential to meet diverse professional needs of mentors and mentees aiming to impact tobacco policy. PMID:28758143

  19. The effect of pavement markings on driving behaviour in curves: a simulator study.

    PubMed

    Ariën, Caroline; Brijs, Kris; Vanroelen, Giovanni; Ceulemans, Wesley; Jongen, Ellen M M; Daniels, Stijn; Brijs, Tom; Wets, Geert

    2017-05-01

    This study investigates the effect of two pavement markings (transverse rumble strips (TRS) and a backward pointing herringbone pattern (HP)) on speed and lateral control in and nearby curves. Two real-world curves with strong indications of a safety problem were replicated as realistic as possible in the simulator. Results show that both speed and lateral control differ between the curves. These behavioural differences are probably due to curve-related dissimilarities with respect to geometric alignment, cross-sectional design and speed limit. TRS and HP both influenced mean speed and mean acceleration/deceleration but not lateral control. TRS generated an earlier and more stable speed reduction than HP which induced significant speed reductions along the curve. The TRS gives drivers more time to generate the right expectations about the upcoming curve. When accidents occur primarily near the curve entry, TRS is recommended. The HP has the potential to reduce accidents at the curve end. Practitioner Summary: Two pavement markings (transversal rumble strips and HP) nearby dangerous curves were investigated in the driving simulator. TRS generated an earlier and more stable speed reduction than HP which induced speed reductions along the curve. The TRS gives drivers more time to generate right expectations about the upcoming curve.

  20. Impulsivity of Noise due to Single Lightweight Vehicles Transit on Transverse Rumble Strip

    NASA Astrophysics Data System (ADS)

    Darus, N.; Haron, Z.; Yahya, K.; Halil, M. H. Abd; Norudin, W. M. A.; Othman, M. H.; Hezmi, M. A.

    2018-03-01

    Transverse Rumble Strips (TRS) acts as safety device that alert inattentive drivers from potential dangers. However, the noise produced due to TRS was reported as noise annoyance among the nearby residents lived adjacent to roadways. Thus, this paper investigates the impulsivity characteristic of noise due to single lightweight vehicles transit on TRS. The objectives of this study are to determine the increase of sound level and to evaluate the impulsivity of noise. Two TRS profiles namely middle overlapped (MO) and middle layer overlapped (MLO) were selected. Three types of single lightweight vehicles which include hatchback, sedan and multipurpose (MPV) were tested at speed of 30, 50 and 70km/h. The sound level was measured using sound level meter (SLM). Noise indices such as LAeq, LAIeqT, LAImax, LAFmax and LASmax were obtained from the measurement. This study considered the differences of LAImax - LAFmax > 2dBA, LAFmax - LAeq ≥ 10dBA, LAIeqT - LAeq ≥ 2dBA and LAImax - LASmax > 6dBA to evaluate the impulsivity of noise. It was found that TRS increased the sound level by at most of 6dBA. Furthermore, all single lightweight vehicles transit on TRS show significant impulsive characteristic. These results proved that TRS produce significant impact to the nearby residents.

  1. 31 CFR 321.22 - Forwarding securities not payable by an agent.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... These instructions are available from a TRS Site or online at www.treasurydirect.gov. [77 FR 16167, Mar... TRS Site. The requests for payment on the securities should be properly certified. Any documentary... TRS Site in accordance with the rules in this part. The Bureau of the Public Debt provides agents with...

  2. 31 CFR 321.22 - Forwarding securities not payable by an agent.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... These instructions are available from a TRS Site or online at www.treasurydirect.gov. [77 FR 16167, Mar... TRS Site. The requests for payment on the securities should be properly certified. Any documentary... TRS Site in accordance with the rules in this part. The Bureau of the Public Debt provides agents with...

  3. A Family of Quantum Protocols

    NASA Astrophysics Data System (ADS)

    Devetak, Igor; Harrow, Aram W.; Winter, Andreas

    2004-12-01

    We introduce three new quantum protocols involving noisy quantum channels and entangled states, and relate them operationally and conceptually with four well-known old protocols. Two of the new protocols (the mother and father) can generate the other five “child” protocols by direct application of teleportation and superdense coding, and can be derived in turn by making the old protocols “coherent.” This gives very simple proofs for two famous old protocols (the hashing inequality and quantum channel capacity) and provides the basis for optimal trade-off curves in several quantum information processing tasks.

  4. International contributions to IAEA-NEA heat transfer databases for supercritical fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leung, L. K. H.; Yamada, K.

    2012-07-01

    An IAEA Coordinated Research Project on 'Heat Transfer Behaviour and Thermohydraulics Code Testing for SCWRs' is being conducted to facilitate collaboration and interaction among participants from 15 organizations. While the project covers several key technology areas relevant to the development of SCWR concepts, it focuses mainly on the heat transfer aspect, which has been identified as the most challenging. Through the collaborating effort, large heat-transfer databases have been compiled for supercritical water and surrogate fluids in tubes, annuli, and bundle subassemblies of various orientations over a wide range of flow conditions. Assessments of several supercritical heat-transfer correlations were performed usingmore » the complied databases. The assessment results are presented. (authors)« less

  5. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    PubMed

    Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander

    2017-01-01

    Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  6. 21 CFR 58.120 - Protocol.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... FOR NONCLINICAL LABORATORY STUDIES Protocol for and Conduct of a Nonclinical Laboratory Study § 58.120 Protocol. (a) Each study shall have an approved written protocol that clearly indicates the objectives and all methods for the conduct of the study. The protocol shall contain, as applicable, the following...

  7. Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination.

    PubMed

    Parel, I; Cutti, A G; Kraszewski, A; Verni, G; Hillstrom, H; Kontaxis, A

    2014-03-01

    Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.

  8. Recapturing the Past with Digital Imaging

    ERIC Educational Resources Information Center

    Gronseth, Susie

    2008-01-01

    Theodore Roosevelt School (TRS) is surrounded by culture and history. Located on the grounds of the former Fort Apache Army Post, TRS serves sixth- through eighth-grade native students, primarily from the White Mountain Apache Tribe. Tradition and culture are so much a part of the TRS students' background of experiences that teachers at the school…

  9. Violence-related Versus Terror-related Stabbings: Significant Differences in Injury Characteristics.

    PubMed

    Rozenfeld, Michael; Givon, Adi; Peleg, Kobi

    2018-05-01

    To demonstrate the gap between injury epidemiology of terror-related stabbings (TRS) and non-terror-related intentional stabbings. Terror attacks with sharp instruments have multiplied recently, with many victims of these incidents presented to hospitals with penetrating injuries. Because most practical experience of surgeons with intentional stabbing injuries comes from treating victims of interpersonal violence, potential gaps in knowledge may exist if injuries from TRS significantly differ from interpersonal stabbings (IPS). A retrospective study of 1615 patients from intentional stabbing events recorded in the Israeli National Trauma Registry during the period of "Knife Intifada" (January 2013-March 2016). All stabbings were divided into TRS and IPS. The 2 categories were compared in terms of sustained injuries, utilization of hospital resources, and clinical outcomes. TRS patients were older, comprised more females and were ethnically homogenous. Most IPS incidents happened on weekdays and at night hours, whereas TRS events peaked midweek during morning and afternoon hours. TRS patients had more injuries of head, face, and neck, and severe head and neck injuries. IPS patients had more abdomen injuries; however, respective injuries in the TRS group were more severe. Greater injury severity of the TRS patients reflected on their higher hospital resources utilization and greater in-hospital mortality. Victims of terror stabbings are profoundly different in their characteristics, sustain injuries of a different profile and greater severity, require more hospital resources, and have worse off clinical outcomes, emphasizing the need of the healthcare systems to adjust itself appropriately to deal successfully with future terror attacks.

  10. PREFACE: 15th Latin American Workshop on Plasma Physics (LAWPP 2014) and 21st IAEA TM on Research Using Small Fusion Devices (RUSFD)

    NASA Astrophysics Data System (ADS)

    Iván Vargas-Blanco, V.; Herrera-Velázquez, J. Julio E.

    2015-03-01

    Written contributions from participants of the Joint 15th Latin American Workshop on Plasma Physics (LAWPP 2014) - 21st IAEA Technical Meeting on Research Using Small Fusion Devices (21st IAEA TM RUSFD). The International Advisory Committees of the 15th Latin American Workshop on Plasma Physics (LAWPP 2014) and the 21st IAEA TM on Research Using Small Fusion Devices (RUSFD), agreed to carry out together this Joint LAWPP 2014 - 21st RUSFD in San José, Costa Rica, on 27-31 January 2014. The Joint LAWPP 2014 - 21st RUSFD meeting, organized by the Instituto Tecnológico de Costa Rica, Universidad Nacional de Costa Rica, and Ad Astra Rocket Company in collaboration with the International Atomic Energy Agency (IAEA). The Latin American Workshop on Plasma Physics (LAWPP) is a series of events which has been held periodically since 1982, with the purpose of providing a forum in which the research of the Latin American plasma physics community can be displayed, as well as fostering collaborations among plasma scientists within the region and with researchers from the rest of the world. Recognized plasma scientists from developed countries are specially invited to the meeting to present the state of the art on several "hot" topics related to plasma physics. It is an open meeting, with an International Advisory Committee, in which the working language is English. It was firstly held in 1982 in Cambuquira, Brazil, followed by workshops in Medellín, Colombia (1985), Santiago de Chile, Chile (1988), Buenos Aires, Argentina (1990), Mexico City, Mexico (1992), Foz do Iguaçu, Brazil (1994, combined with the International Congress on Plasma Physics (ICPP)), Caracas, Venezuela (1997), Tandil, Argentina (1998), La Serena, Chile (2000), Sao Pedro, Brazil (2003), Mexico City, Mexico (2005), Caracas, Venezuela (2007), Santiago de Chile, Chile (2010, combined with the ICPP) and Mar de Plata, Argentina (2011). The 21st IAEA TM on Research Using Small Fusion Devices is an ideal forum for

  11. The central electrode correction factor for high-Z electrodes in small ionization chambers.

    PubMed

    Muir, B R; Rogers, D W O

    2011-02-01

    Recent Monte Carlo calculations of beam quality conversion factors for ion chambers that use high-Z electrodes [B. R. Muir and D. W. O. Rogers, Med. Phys. 37, 5939-5950 (2010)] have shown large deviations of kQ values from values calculated using the same techniques as the TG-51 and TRS-398 protocols. This report investigates the central electrode correction factor, Pcel, for these chambers. Ionization chambers are modeled and Pcel is calculated using the EGSnrc user code egs_chamber for three cases: in photon and electron beams under reference conditions; as a function of distance from an iridium-192 point source in a water phantom; and as a function of depth in a water phantom on which a 200 kVp x-ray source or 6 MV beam is incident. In photon beams, differences of up to 3% between Pcel calculations for a chamber with a high-Z electrode and those used by TG-51 for a 1 mm diameter aluminum electrode are observed. The central electrode correction factor for a given value of the beam quality specifier is different depending on the amount of filtration of the photon beam. However, in an unfiltered 6 MV beam, Pcel, varies by only 0.3% for a chamber with a high-Z electrode as the depth is varied from 1 to 20 cm in water. The difference between Pcel calculations for chambers with high-Z electrodes and TG-51 values for a chamber with an aluminum electrode is up to 0.45% in electron beams. The central electrode correction, which is roughly proportional to the chambers absorbed dose sensitivity, is found to be large and variable as a function of distance for chambers with high-Z and aluminum electrodes in low-energy photon fields. In this work, ionization chambers that employ high-Z electrodes have been shown to be problematic in various situations. For beam quality conversion factors, the ratio of Pcel in a beam quality Q to that in a Co-60 beam is required; for some chambers, kQ is significantly different from current dosimetry protocol values because of central

  12. In Vivo, Non-Invasive Characterization of Human Bone by Hybrid Broadband (600-1200 nm) Diffuse Optical and Correlation Spectroscopies.

    PubMed

    Konugolu Venkata Sekar, Sanathana; Pagliazzi, Marco; Negredo, Eugènia; Martelli, Fabrizio; Farina, Andrea; Dalla Mora, Alberto; Lindner, Claus; Farzam, Parisa; Pérez-Álvarez, Núria; Puig, Jordi; Taroni, Paola; Pifferi, Antonio; Durduran, Turgut

    2016-01-01

    Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600-1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care.

  13. A Simple XML Producer-Consumer Protocol

    NASA Technical Reports Server (NTRS)

    Smith, Warren; Gunter, Dan; Quesnel, Darcy

    2000-01-01

    This document describes a simple XML-based protocol that can be used for producers of events to communicate with consumers of events. The protocol described here is not meant to be the most efficient protocol, the most logical protocol, or the best protocol in any way. This protocol was defined quickly and it's intent is to give us a reasonable protocol that we can implement relatively easily and then use to gain experience in distributed event services. This experience will help us evaluate proposals for event representations, XML-based encoding of information, and communication protocols. The next section of this document describes how we represent events in this protocol and then defines the two events that we choose to use for our initial experiments. These definitions are made by example so that they are informal and easy to understand. The following section then proceeds to define the producer-consumer protocol we have agreed upon for our initial experiments.

  14. “Counterfactual” quantum protocols

    NASA Astrophysics Data System (ADS)

    Vaidman, L.

    2016-05-01

    The counterfactuality of recently proposed protocols is analyzed. A definition of “counterfactuality” is offered and it is argued that an interaction-free measurement (IFM) of the presence of an opaque object can be named “counterfactual”, while proposed “counterfactual” measurements of the absence of such objects are not counterfactual. The quantum key distribution protocols which rely only on measurements of the presence of the object are counterfactual, but quantum direct communication protocols are not. Therefore, the name “counterfactual” is not appropriate for recent “counterfactual” protocols which transfer quantum states by quantum direct communication.

  15. [Multidisciplinary protocol for computed tomography imaging and angiographic embolization of splenic injury due to trauma: assessment of pre-protocol and post-protocol outcomes].

    PubMed

    Koo, M; Sabaté, A; Magalló, P; García, M A; Domínguez, J; de Lama, M E; López, S

    2011-11-01

    To assess conservative treatment of splenic injury due to trauma, following a protocol for computed tomography (CT) and angiographic embolization. To quantify the predictive value of CT for detecting bleeding and need for embolization. The care protocol developed by the multidisciplinary team consisted of angiography with embolization of lesions revealed by contrast extravasation under CT as well as embolization of grade III-V injuries observed, or grade I-II injuries causing hemodynamic instability and/or need for blood transfusion. We collected data on demographic variables, injury severity score (ISS), angiographic findings, and injuries revealed by CT. Pre-protocol and post-protocol outcomes were compared. The sensitivity and specificity of CT findings were calculated for all patients who required angiographic embolization. Forty-four and 30 angiographies were performed in the pre- and post-protocol periods, respectively. The mean (SD) ISSs in the two periods were 25 (11) and 26 (12), respectively. A total of 24 (54%) embolizations were performed in the pre-protocol period and 28 (98%) after implementation of the protocol. Two and 7 embolizations involved the spleen in the 2 periods, respectively; abdominal laparotomies numbered 32 and 25, respectively, and 10 (31%) vs 4 (16%) splenectomies were performed. The specificity and sensitivity values for contrast extravasation found on CT and followed by embolization were 77.7% and 79.5%. The implementation of this multidisciplinary protocol using CT imaging and angiographic embolization led to a decrease in the number of splenectomies. The protocol allows us to take a more conservative treatment approach.

  16. Diagnostic accuracy of magnetic resonance imaging, transvaginal, and transrectal ultrasonography in deep infiltrating endometriosis

    PubMed Central

    Alborzi, Saeed; Rasekhi, Alireza; Shomali, Zahra; Madadi, Gooya; Alborzi, Mahshid; Kazemi, Mahboobeh; Hosseini Nohandani, Azam

    2018-01-01

    Abstract To determine the diagnostic accuracy of pelvic magnetic resonance imaging (MRI), transvaginal sonography (TVS), and transrectal sonography (TRS) in diagnosis of deep infiltrating endometriosis (DIE). This diagnostic accuracy study was conducted during a 2-year period including a total number of 317 patients with signs and symptoms of endometriosis. All the patients were evaluated by pelvic MRI, TVS, and TRS in the same center. The criterion standard was considered to be the laparoscopy and histopathologic examination. Of 317 patients being included in the present study, 252 tested positive for DIE. The sensitivity, specificity, positive predictive value, and negative predictive value of TVS was found to be 83.3%, 46.1%, 85.7%, and 41.6%, respectively. These variables were 80.5%, 18.6%, 79.3%, and 19.7% for TRS and 90.4%, 66.1%, 91.2%, and 64.1% for MRI, respectively. MRI had the highest accuracy (85.4%) when compared to TVS (75.7%) and TRS (67.8%). The sensitivity of TRS, TVS, and MRI in uterosacral ligament DIE was 82.8%, 70.9%, and 63.6%, respectively. On the contrary, specificity had a reverse trend, favoring MRI (93.9%, 92.8%, and 89.8% for TVS and TRS, respectively). The results of the present study demonstrated that TVS and TRS have appropriate diagnostic accuracy in diagnosis of DIE comparable to MRI. PMID:29465552

  17. A Unified Fault-Tolerance Protocol

    NASA Technical Reports Server (NTRS)

    Miner, Paul; Gedser, Alfons; Pike, Lee; Maddalon, Jeffrey

    2004-01-01

    Davies and Wakerly show that Byzantine fault tolerance can be achieved by a cascade of broadcasts and middle value select functions. We present an extension of the Davies and Wakerly protocol, the unified protocol, and its proof of correctness. We prove that it satisfies validity and agreement properties for communication of exact values. We then introduce bounded communication error into the model. Inexact communication is inherent for clock synchronization protocols. We prove that validity and agreement properties hold for inexact communication, and that exact communication is a special case. As a running example, we illustrate the unified protocol using the SPIDER family of fault-tolerant architectures. In particular we demonstrate that the SPIDER interactive consistency, distributed diagnosis, and clock synchronization protocols are instances of the unified protocol.

  18. Internet Protocol Transition Workbook

    DTIC Science & Technology

    1982-03-01

    U N C-* INTERNET PROTOCOL TRANSITION WORKBOOK March 1982 Network Information Canter SRI International Menlo Park, CA 94025 t tv l...Feinler Network Information Center SRI International Menlo Park. California 94025 (415) 859-3695 FEINLEROSRI-NIC (Online mail) [Page ii] I.7 Internet ...31 Postel. J., " Internet Control Message Protocol - DARPA Internet Program Protocol Specification." RFC 792, USC/ Information Sciences Institute

  19. Treatment algorithms and protocolized care.

    PubMed

    Morris, Alan H

    2003-06-01

    Excess information in complex ICU environments exceeds human decision-making limits and likely contributes to unnecessary variation in clinical care, increasing the likelihood of clinical errors. I reviewed recent critical care clinical trials searching for information about the impact of protocol use on clinically pertinent outcomes. Several recently published clinical trials illustrate the importance of distinguishing efficacy and effectiveness trials. One of these trials illustrates the danger of conducting effectiveness trials before the efficacy of an intervention is established. The trials also illustrate the importance of distinguishing guidelines and inadequately explicit protocols from adequately explicit protocols. Only adequately explicit protocols contain enough detail to lead different clinicians to the same decision when faced with the same clinical scenario. Differences between guidelines and protocols are important. Guidelines lack detail and provide general guidance that requires clinicians to fill in many gaps. Computerized or paper-based protocols are detailed and, when used for complex clinical ICU problems, can generate patient-specific, evidence-based therapy instructions that can be carried out by different clinicians with almost no interclinician variability. Individualization of patient therapy can be preserved by these protocols when they are driven by individual patient data. Explicit decision-support tools (eg, guidelines and protocols) have favorable effects on clinician and patient outcomes and can reduce the variation in clinical practice. Guidelines and protocols that aid ICU decision makers should be more widely distributed.

  20. Comment on "flexible protocol for quantum private query based on B92 protocol"

    NASA Astrophysics Data System (ADS)

    Chang, Yan; Zhang, Shi-Bin; Zhu, Jing-Min

    2017-03-01

    In a recent paper (Quantum Inf Process 13:805-813, 2014), a flexible quantum private query (QPQ) protocol based on B92 protocol is presented. Here we point out that the B92-based QPQ protocol is insecure in database security when the channel has loss, that is, the user (Alice) will know more records in Bob's database compared with she has bought.

  1. Culturally sensitive and universal measure of resilience for Japanese populations: Tachikawa Resilience Scale in comparison with Resilience Scale 14-item version.

    PubMed

    Nishi, Daisuke; Uehara, Ritei; Yoshikawa, Eisho; Sato, Goro; Ito, Masaya; Matsuoka, Yutaka

    2013-04-01

    Although scales specific to resilience are available and widely used, qualities of resilience could be culturally sensitive. This study aimed to develop a concise scale of resilience for Japanese populations, and compare its validity to that of the Resilience Scale 14-item version (RS-14), one of the most widely used scales for measuring resilience. The Tachikawa Resilience Scale (TRS) was developed on the basis of data obtained from unstructured interviews with Japanese motor vehicle accident survivors without psychiatric disorder. The reliability and validity of the TRS and RS-14 were then examined in cross-sectional studies performed with 523 company workers and 140 psychiatric outpatients. The TRS and RS-14 were negatively correlated with depressive symptoms in company workers and psychiatric outpatients and with anxiety in psychiatric outpatients, and were positively correlated with social support in company workers. Internal consistency and test-retest reliability of the TRS were high. Construct validity of the TRS was equivalent to that of the RS-14 in company workers, and higher than that of the RS-14 in psychiatric outpatients. The reliability and validity of the TRS and RS-14 in Japanese company workers and patients with psychiatric disorders were acceptable. The validity of the TRS was equivalent to or better than that of the RS-14. Although the TRS cannot be regarded as an established scale due to a lack of theoretical rationale, the results of this study suggest that scales measuring resilience that cover cultural aspects might be more relevant in given populations. © 2013 The Authors. Psychiatry and Clinical Neurosciences © 2013 Japanese Society of Psychiatry and Neurology.

  2. Problematic protocols: An overview of medical research protocols not approved by the LUMC medical ethics review committee.

    PubMed

    Tersmette, Derek Gideon; Engberts, Dirk Peter

    2017-01-01

    The Committee for Medical Ethics (CME) of Leiden University Medical Center (LUMC) was established as the first medical ethics reviewing committee (MREC) in the Netherlands. In the period 2000-2010 the CME received 2,162 protocols for review. Some of these protocols were never approved. Until now, there has existed neither an overview of these failed protocols nor an overview of the reasons for their failure. This report draws on data from the digital database, the physical archives, and the minutes of the meetings of the CME. Additional information has been obtained from the Central Committee on Research involving Human Subjects (CCRH) and survey-based research. Protocols were itemized based on characteristic features and their reviewing procedures were analyzed. In total, 1,952 out of 2,162 research protocols submitted during 2000-2010 (90.3%) were approved by the CME; 210 of 2,162 protocols (9.7%) were not approved. Of these 210 protocols, 177 failed due to reasons not related to CME reviewing. In 15 cases CME reviewing led to protocol failure, while another 10 protocols were rejected outright. Eight of the 210 submitted protocols without approval had been conducted prior to submission. In the aforementioned period, little protocol failure occurred. For the most part, protocol failure was caused by problems that are not CME related. This type of failure has several identifiable factors, none of which have anything to do with the ethical reviewing procedure by the CME. A mere 1.2% of protocols failed due to ethical review. Unacceptable burden and risks to the subject and an inadequate methodology are the most common reasons for this CME-related protocol failure.

  3. Microcomputer Nurse-Practitioner Protocols

    PubMed Central

    Way, Anthony B.; Rowley, Blair A.; White, Melanie A.

    1982-01-01

    We have developed a set of protocols on a microcomputer to assist in the management of a geographically isolated nurse practitioner. If a mid-level practitioner is supervised by a physician, some system is needed to ensure that approved care is being provided. The currently available paper-based protocols do not adequately serve all the needs for training, auditing, and record keeping. Conversely, adequate systems based on large computers are not feasible for small clinics. We have therefore developed a microcomputer-based system of protocols for a small rural nurse-practitioner's clinic. Our programs are designed for direct use by the practitioners while the patient is in the clinic. The user is given immediate feedback about any errors. The supervisor is later provided with a summary of the protocol uses and errors, and a copy of any erroneous records. The system appears to be easy to use by the nurse practitioner. The protocols are quickly learned and auditing is facilitated.

  4. Protocols — EDRN Public Portal

    Cancer.gov

    EDRN investigators protocols. The following is a list of the EDRN protocols that have been captured and curated. Additional information will be added as it is available. Contact information is provided as part of the detail for each protocol.

  5. Leveraging National Healthcare Reform to Improve Army National Guard Readiness

    DTIC Science & Technology

    2010-03-01

    Specifically, monitoring Soldier use of TRICARE Reserve Select (TRS) to meet the health insurance mandate and changing the TRS benefit by developing...TRS benefit by developing incentives for healthy behaviors and eliminating cost sharing for preventive services, will help control health care costs...amount of heath care gained relative to the amount spent) can improve readiness while controlling cost growth. 50 In 2008, health care expenditures

  6. A Report on IAEA/RCA C7-RAS 6/061-004 Training Course in Chiba, Japan in 2014

    PubMed Central

    Kosuda, Shigeru; Saga, Tsuneo; Paez, Diana

    2015-01-01

    The C7-RAS 6/061-004 training course by the International Atomic Energy Agency/Regional Cooperative Agreement (IAEA/RCA) was held in Chiba in 2014. The syllabus, pre- and post-course evaluations, and survey questionnaire results were assembled in this course. The post-course evaluation, including 32 questions similar to the pre-course evaluation, was performed right after the end of the final educational lecture. The mean score showed an improvement, with the score rising from 57.0 points at the beginning to 66.5 points at the end. Among 22 trainees, the greatest score was in a higher range, with an improvement from 82 points at the beginning to 88 points at the end. The grading distribution, with regard to the training course, was as follows: excellent (68.2%), good (31.8%), average (0%), fair (0%), and poor (0%). This report on the training course, held in Chiba in 2014, will contribute to the future global plans of IAEA/RCA. Continuous training courses in member states are required to decrease the present disparities in the knowledge level, instrumentation, and human resources.

  7. Using semantics for representing experimental protocols.

    PubMed

    Giraldo, Olga; García, Alexander; López, Federico; Corcho, Oscar

    2017-11-13

    An experimental protocol is a sequence of tasks and operations executed to perform experimental research in biological and biomedical areas, e.g. biology, genetics, immunology, neurosciences, virology. Protocols often include references to equipment, reagents, descriptions of critical steps, troubleshooting and tips, as well as any other information that researchers deem important for facilitating the reusability of the protocol. Although experimental protocols are central to reproducibility, the descriptions are often cursory. There is the need for a unified framework with respect to the syntactic structure and the semantics for representing experimental protocols. In this paper we present "SMART Protocols ontology", an ontology for representing experimental protocols. Our ontology represents the protocol as a workflow with domain specific knowledge embedded within a document. We also present the S ample I nstrument R eagent O bjective (SIRO) model, which represents the minimal common information shared across experimental protocols. SIRO was conceived in the same realm as the Patient Intervention Comparison Outcome (PICO) model that supports search, retrieval and classification purposes in evidence based medicine. We evaluate our approach against a set of competency questions modeled as SPARQL queries and processed against a set of published and unpublished protocols modeled with the SP Ontology and the SIRO model. Our approach makes it possible to answer queries such as Which protocols use tumor tissue as a sample. Improving reporting structures for experimental protocols requires collective efforts from authors, peer reviewers, editors and funding bodies. The SP Ontology is a contribution towards this goal. We build upon previous experiences and bringing together the view of researchers managing protocols in their laboratory work. Website: https://smartprotocols.github.io/ .

  8. Development of independent MU/treatment time verification algorithm for non-IMRT treatment planning: A clinical experience

    NASA Astrophysics Data System (ADS)

    Tatli, Hamza; Yucel, Derya; Yilmaz, Sercan; Fayda, Merdan

    2018-02-01

    The aim of this study is to develop an algorithm for independent MU/treatment time (TT) verification for non-IMRT treatment plans, as a part of QA program to ensure treatment delivery accuracy. Two radiotherapy delivery units and their treatment planning systems (TPS) were commissioned in Liv Hospital Radiation Medicine Center, Tbilisi, Georgia. Beam data were collected according to vendors' collection guidelines, and AAPM reports recommendations, and processed by Microsoft Excel during in-house algorithm development. The algorithm is designed and optimized for calculating SSD and SAD treatment plans, based on AAPM TG114 dose calculation recommendations, coded and embedded in MS Excel spreadsheet, as a preliminary verification algorithm (VA). Treatment verification plans were created by TPSs based on IAEA TRS 430 recommendations, also calculated by VA, and point measurements were collected by solid water phantom, and compared. Study showed that, in-house VA can be used for non-IMRT plans MU/TT verifications.

  9. Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinshaw, J. Louis, E-mail: jhinshaw@uwhealth.or; Littrup, Peter J.; Durick, Nathan

    2010-12-15

    The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols.more » Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different from the double freeze-thaw protocol (mean diameter: 1.67 {+-} 0.41 cm vs. 1.66 {+-} 0.21 cm, P = 0.77; area: 2.1 {+-} 0.48 cm{sup 2} vs. 1.99 {+-} 0.62 cm{sup 2}, P = 0.7; and circularity: 0.95 {+-} 0.04 vs. 0.96 {+-} 0.03, P = 0.62, respectively). This study suggests that there may be several advantages of a triple freeze-thaw protocol for pulmonary cryoablation, including earlier identification of the imaging findings associated with the ablation, the promise of a shorter procedure time or larger zones of ablation, and theoretically, more effective cytotoxicity related to the additional freeze-thaw cycle.« less

  10. Progress and status of the IAEA coordinated research project: production of Mo-99 using LEU fission or neutron activation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldman, Ira N.; Adelfang, Pablo; Ramamoorthy, Natesan

    2008-07-15

    Since late 2004, the IAEA has developed and implemented a Coordinated Research Project (CRP) to assist countries interested in initiating indigenous, small-scale production of Mo-99 to meet local nuclear medicine requirements. The objective of the CRP is to provide interested countries with access to non-proprietary technologies and methods to produce Mo-99 using LEU foil or LEU mini-plate targets, or for the utilization of n,gamma neutron activation, e.g. through the use of gel generators. The project has made further progress since the RERTR 2006 meeting, with a Technical Workshop on Operational Aspects of Mo99 Production held 28-30 November 2006 in Viennamore » and the Second Research Coordination Meeting held in Bucharest, Romania 16-20 April 2007. The paper describes activities carried out as noted above, and as well as the provision of LEU foils to a number of participants, and the progress by a number of groups in preparing for LEU target assembly and disassembly, irradiation, chemical processing, and waste management. The participants' progress in particular on thermal hydraulics computations required for using LEU targets is notable, as also the progress in gel generator plant operations in India and Kazakhstan. Poland has joined as a new research agreement holder and an application by Egypt to be a contract holder is undergoing internal review in the IAEA and is expected to be approved. The IAEA has also participated in several open meetings of the U.S. National Academy of Sciences Study on Producing Medical Radioisotopes without HEU, which will also be discussed in the paper. (author)« less

  11. FTP Extensions for Variable Protocol Specification

    NASA Technical Reports Server (NTRS)

    Allman, Mark; Ostermann, Shawn

    2000-01-01

    The specification for the File Transfer Protocol (FTP) assumes that the underlying network protocols use a 32-bit network address and a 16-bit transport address (specifically IP version 4 and TCP). With the deployment of version 6 of the Internet Protocol, network addresses will no longer be 32-bits. This paper species extensions to FTP that will allow the protocol to work over a variety of network and transport protocols.

  12. Experiences using IAEA Code of practice for radiation sterilization of tissue allografts: Validation and routine control

    NASA Astrophysics Data System (ADS)

    Hilmy, N.; Febrida, A.; Basril, A.

    2007-11-01

    Problems of tissue allografts in using International Standard (ISO) 11137 for validation of radiation sterilization dose (RSD) are limited and low numbers of uniform samples per production batch, those are products obtained from one donor. Allograft is a graft transplanted between two different individuals of the same species. The minimum number of uniform samples needed for verification dose (VD) experiment at the selected sterility assurance level (SAL) per production batch according to the IAEA Code is 20, i.e., 10 for bio-burden determination and the remaining 10 for sterilization test. Three methods of the IAEA Code have been used for validation of RSD, i.e., method A1 that is a modification of method 1 of ISO 11137:1995, method B (ISO 13409:1996), and method C (AAMI TIR 27:2001). This paper describes VD experiments using uniform products obtained from one cadaver donor, i.e., cancellous bones, demineralized bone powders and amnion grafts from one life donor. Results of the verification dose experiments show that RSD is 15.4 kGy for cancellous and demineralized bone grafts and 19.2 kGy for amnion grafts according to method A1 and 25 kGy according to methods B and C.

  13. Evaluation of a new tension relief system for securing wound closure: A single-centre, Chinese cohort study

    PubMed Central

    Huahui, Zhang; Dan, Xue; Hongfei, Jiang; Hang, Hu; Chunmao, Han; Haitao, Ren; Jianxin, Yu; Zhiping, Tao

    2016-01-01

    BACKGROUND Wounds that have been closed under excessive tension, and skin defects that cannot be closed primarily, pose a daily challenge for the reconstructive surgeon. OBJECTIVE To evaluate a new tension relief system (TRS) device for skin stretching and secure wound closure. METHODS From September 2013 to March 2014, a consecutive series of 41 Chinese patients with 43 wounds were enrolled for application of 50 cycles of TRS therapy. TRS was used for two main clinical applications: closure of a variety of surgical/traumatic wounds; and securing wound closure after high-tension suture closure. Basic information and details regarding this therapy and its complications were recorded. Follow-up visits were conducted three to six months after wound closure. RESULTS Mean residual wound width decreased approximately 20% every two days during cycles of TRS therapy. Infection was the most common complication (five cases). Other complications included dehiscence (two cases) and pressure ulcer (one case). At the six-month follow-up visit, (21 wounds in 20 patients), both the extent of healing and the scar were acceptable. DISCUSSION There are no absolute contraindications to TRS therapy. The authors have formulated instructions for the prevention and treatment of the most common complications. CONCLUSIONS The results demonstrate that TRS therapy is a simple, effective method for primary closure of difficult wounds, and large skin and soft-tissue defects. Larger randomized studies are required to further evaluate of the effectiveness, indications, complications and cost effectiveness of this innovative TRS therapy. PMID:28439506

  14. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  15. Comparison of results of cycles treated with modified mild protocol and short protocol for ovarian stimulation.

    PubMed

    Coelho, F; Aguiar, L F; Cunha, G S P; Cardinot, N; Lucena, E

    2014-01-01

    The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate.

  16. Splenium microstructure is related to two dimensions of reading skill.

    PubMed

    Frye, Richard E; Hasan, Khader; Xue, Lian; Strickland, David; Malmberg, Benjamin; Liederman, Jacqueline; Papanicolaou, Andrew

    2008-10-29

    Inconsistent differences in the corpus callosum (CC) structure between dyslexic readers (DRs) and typical readers (TRs) have been reported. We examine differences in CC splenium microstructure and the association of splenium microstructure with reading-related skills. Nine DRs and 18 TRs completed a reading skills battery and diffusion tensor imaging. DRs had higher splenium fractional anisotropy (FA) and axial diffusivity (LA) as compared with TRs. Retrieval of orthographic information from the language lexicon was negatively associated with FA and LA within both reading groups. Phonological awareness was positively associated with splenium FA and LA in TRs but not DRs. This study suggests two white matter pathways that may be differentially associated with reading skills in the CC splenium.

  17. 21 CFR 312.30 - Protocol amendments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (b) Changes in a protocol. (1) A sponsor shall submit a protocol amendment describing any change in a Phase 1 protocol that significantly affects the safety of subjects or any change in a Phase 2 or 3... forth the provisions under which new protocols may be submitted and changes in previously submitted...

  18. 21 CFR 312.30 - Protocol amendments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (b) Changes in a protocol. (1) A sponsor shall submit a protocol amendment describing any change in a Phase 1 protocol that significantly affects the safety of subjects or any change in a Phase 2 or 3... forth the provisions under which new protocols may be submitted and changes in previously submitted...

  19. Modeling the costs and benefits of temporary recommendations for poliovirus exporting countries to vaccinate international travelers.

    PubMed

    Duintjer Tebbens, Radboud J; Thompson, Kimberly M

    2017-07-05

    Recognizing that infectious agents readily cross international borders, the International Health Regulations Emergency Committee issues Temporary Recommendations (TRs) that include vaccination of travelers from countries affected by public health emergencies, including serotype 1 wild polioviruses (WPV1s). This analysis estimates the costs and benefits of TRs implemented by countries with reported WPV1 during 2014-2016 while accounting for numerous uncertainties. We estimate the TR costs based on programmatic data and prior economic analyses and TR benefits by simulating potential WPV1 outbreaks in the absence of the TRs using the rate and extent of WPV1 importation outbreaks per reported WPV1 case during 2004-2013 and the number of reported WPV1 cases that occurred in countries with active TRs. The benefits of TRs outweigh the costs in 77% of model iterations, resulting in expected incremental net economic benefits of $210 million. Inclusion of indirect costs increases the costs by 13%, the expected savings from prevented outbreaks by 4%, and the expected incremental net benefits by 3%. Despite the considerable costs of implementing TRs, this study provides health and economic justification for these investments in the context of managing a disease in advanced stages of its global eradication. Copyright © 2017 The Auhors. Published by Elsevier Ltd.. All rights reserved.

  20. Quarantine and protocol

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The purpose of the Orbiting Quarantine Facility is to provide maximum protection of the terrestrial biosphere by ensuring that the returned Martian samples are safe to bring to Earth. The protocol designed to detect the presence of biologically active agents in the Martian soil is described. The protocol determines one of two things about the sample: (1) that it is free from nonterrestrial life forms and can be sent to a terrestrial containment facility where extensive chemical, biochemical, geological, and physical investigations can be conducted; or (2) that it exhibits "biological effects" of the type that dictate second order testing. The quarantine protocol is designed to be conducted on a small portion of the returned sample, leaving the bulk of the sample undisturbed for study on Earth.

  1. An Evaluation of Protocol Enhancing Proxies and File Transport Protocols for Satellite Communication

    NASA Technical Reports Server (NTRS)

    Finch, Patrick Eugene; Sullivan, Donald; Ivancic, William D.

    2012-01-01

    NASA is utilizing Global Hawk aircraft in high-altitude, long-duration Earth science missions. Communications with the onboard research equipment and sensors (the science payload) is via Ku-Band radio utilizing satellites in geostationary orbits. All payload communications use standard Internet Protocols and routing, and much of the data to be transferred is comprised of very large files. The science community is interested in fully utilizing these communication links to retrieve data as quickly and reliably as possible. A test bed was developed at NASA Ames to evaluate modern transport protocols as well as Protocol Enhancing Proxies (PEPs) to determine what tools best fit the needs of the science community. This paper describes the test bed used, the protocols, the PEPs that were evaluated, the particular tests performed and the results and conclusions.

  2. Market Research Survey of Commercial Off-The-Shelf (COTS) Portable MS Systems for IAEA Safeguards Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Garret L.; Hager, George J.; Barinaga, Charles J.

    2013-02-01

    This report summarizes the results for the market research survey of mass spectrometers that are deemed pertinent to International Atomic Energy Agency (IAEA) needs and strategic objectives. The focus of the report is on MS instruments that represent currently available (or soon to be) commercial off-the shelf (COTS) technology and weigh less than 400 pounds. A compilation of all available MS instruments (36 COTS and 2 R&D) is presented, along with pertinent information regarding each instrument.

  3. Comparison of Results of Cycles Treated with Modified Mild Protocol and Short Protocol for Ovarian Stimulation

    PubMed Central

    Aguiar, L. F.; Cunha, G. S. P.; Cardinot, N.; Lucena, E.

    2014-01-01

    The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate. PMID:25763398

  4. Protocols for Automated Protist Analysis

    DTIC Science & Technology

    2011-12-01

    Report No: CG-D-14-13 Protocols for Automated Protist Analysis December 2011 Distribution Statement A: Approved for public...release; distribution is unlimited. Protocols for Automated Protist Analysis ii UNCLAS//Public | CG-926 RDC | B. Nelson, et al. | Public...Director United States Coast Guard Research & Development Center 1 Chelsea Street New London, CT 06320 Protocols for Automated Protist Analysis

  5. Minor physical anomalies and craniofacial measures in patients with treatment-resistant schizophrenia.

    PubMed

    Lin, A-S; Chang, S-S; Lin, S-H; Peng, Y-C; Hwu, H-G; Chen, W J

    2015-07-01

    Schizophrenia patients have higher rates of minor physical anomalies (MPAs) than controls, particularly in the craniofacial region; this difference lends support to the neurodevelopmental model of schizophrenia. Whether MPAs are associated with treatment response in schizophrenia remains unknown. The aim of this case-control study was to investigate whether more MPAs and specific quantitative craniofacial features in patients with schizophrenia are associated with operationally defined treatment resistance. A comprehensive scale, consisting of both qualitatively measured MPAs and quantitative measurements of the head and face, was applied in 108 patients with treatment-resistant schizophrenia (TRS) and in 104 non-TRS patients. Treatment resistance was determined according to the criteria proposed by Conley & Kelly (2001; Biological Psychiatry 50, 898-911). Our results revealed that patients with TRS had higher MPA scores in the mouth region than non-TRS patients, and the two groups also differed in four quantitative measurements (facial width, lower facial height, facial height, and length of the philtrum), after controlling for multiple comparisons using the false discovery rate. Among these dysmorphological measurements, three MPA item types (mouth MPA score, facial width, and lower facial height) and earlier disease onset were further demonstrated to have good discriminant validity in distinguishing TRS from non-TRS patients in a multivariable logistic regression analysis, with an area under the curve of 0.84 and a generalized R 2 of 0.32. These findings suggest that certain MPAs and craniofacial features may serve as useful markers for identifying TRS at early stages of the illness.

  6. Inverse association between urbanicity and treatment resistance in schizophrenia.

    PubMed

    Wimberley, Theresa; Pedersen, Carsten B; MacCabe, James H; Støvring, Henrik; Astrup, Aske; Sørensen, Holger J; Horsdal, Henriette T; Mortensen, Preben B; Gasse, Christiane

    2016-07-01

    Living in a larger city is associated with increased risk of schizophrenia; and world-wide, consistent evidence shows that the higher the degree of urbanicity the higher the risk of schizophrenia. However, the association between urbanicity and treatment-resistant schizophrenia (TRS) as a more severe form of schizophrenia or separate entity of schizophrenia has not been fully explored yet. We aimed to investigate the association between urbanicity and incidence of TRS. A large Danish population-based cohort of all individuals with a first schizophrenia diagnosis after 1996 was followed until 2013 applying survival analysis techniques. TRS was assessed using a treatment-based proxy, defined as the earliest observed instance of either clozapine initiation or hospital admission due to schizophrenia after having received two prior antipsychotic monotherapy trials of adequate duration. Among the 13,349 schizophrenia patients, 17.3% experienced TRS during follow-up (median follow-up: 7years, inter-quartile range: 3-12years). The 5-year risk of TRS ranged from 10.5% in the capital area to 17.6% in the rural areas. Compared with individuals with schizophrenia residing in the capital area, hazard ratios were 1.44 (1.31-1.59) for provincial areas and 1.60 (1.43-1.79) for rural areas. Higher rates of TRS were found in less urbanized areas. The different direction of urban-rural differences regarding TRS and schizophrenia risk may indicate urban-rural systematic differences in treatment practices, or different urban-rural aetiologic types of schizophrenia. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. 47 CFR 6.17 - Informal complaints; form and content.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...., letter, facsimile transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette... transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette recording, braille; or...

  8. 47 CFR 6.17 - Informal complaints; form and content.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...., letter, facsimile transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette... transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette recording, braille; or...

  9. 47 CFR 6.17 - Informal complaints; form and content.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...., letter, facsimile transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette... transmission, telephone (voice/TRS/TTY), Internet e-mail, ASCII text, audio-cassette recording, braille; or...

  10. GENERIC VERIFICATION PROTOCOL: DISTRIBUTED GENERATION AND COMBINED HEAT AND POWER FIELD TESTING PROTOCOL

    EPA Science Inventory

    This report is a generic verification protocol by which EPA’s Environmental Technology Verification program tests newly developed equipment for distributed generation of electric power, usually micro-turbine generators and internal combustion engine generators. The protocol will ...

  11. Objective and automated protocols for the evaluation of biomedical search engines using No Title Evaluation protocols.

    PubMed

    Campagne, Fabien

    2008-02-29

    The evaluation of information retrieval techniques has traditionally relied on human judges to determine which documents are relevant to a query and which are not. This protocol is used in the Text Retrieval Evaluation Conference (TREC), organized annually for the past 15 years, to support the unbiased evaluation of novel information retrieval approaches. The TREC Genomics Track has recently been introduced to measure the performance of information retrieval for biomedical applications. We describe two protocols for evaluating biomedical information retrieval techniques without human relevance judgments. We call these protocols No Title Evaluation (NT Evaluation). The first protocol measures performance for focused searches, where only one relevant document exists for each query. The second protocol measures performance for queries expected to have potentially many relevant documents per query (high-recall searches). Both protocols take advantage of the clear separation of titles and abstracts found in Medline. We compare the performance obtained with these evaluation protocols to results obtained by reusing the relevance judgments produced in the 2004 and 2005 TREC Genomics Track and observe significant correlations between performance rankings generated by our approach and TREC. Spearman's correlation coefficients in the range of 0.79-0.92 are observed comparing bpref measured with NT Evaluation or with TREC evaluations. For comparison, coefficients in the range 0.86-0.94 can be observed when evaluating the same set of methods with data from two independent TREC Genomics Track evaluations. We discuss the advantages of NT Evaluation over the TRels and the data fusion evaluation protocols introduced recently. Our results suggest that the NT Evaluation protocols described here could be used to optimize some search engine parameters before human evaluation. Further research is needed to determine if NT Evaluation or variants of these protocols can fully substitute

  12. Protocol Coordinator | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID), Clinical Center (CC), National Institute of Heart, Lung and Blood Institute (NHLBI), National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), National Center for Advancing Translational Sciences (NCATS), National Institute of Neurological Disorders and Stroke (NINDS), and the National Institute of Mental Health (NIMH). Since its inception in 2001, CMRP’s ability to provide rapid responses, high-quality solutions, and to recruit and retain experts with a variety of backgrounds to meet the growing research portfolios of NCI, NIAID, CC, NHLBI, NIAMS, NCATS, NINDS, and NIMH has led to the considerable expansion of the program and its repertoire of support services. CMRP’s support services are strategically aligned with the program’s mission to provide comprehensive, dedicated support to assist National Institutes of Health researchers in providing the highest quality of clinical research in compliance with applicable regulations and guidelines, maintaining data integrity, and protecting human subjects. For the scientific advancement of clinical research, CMRP services include comprehensive clinical trials, regulatory, pharmacovigilance, protocol navigation and development, and programmatic and project management support for facilitating the conduct of 400+ Phase I, II, and III domestic and international trials on a yearly basis. These trials investigate the prevention, diagnosis, treatment of, and therapies for cancer, influenza, HIV, and other infectious diseases and viruses such as hepatitis C, tuberculosis, malaria, and Ebola virus; heart, lung, and

  13. Quantum Tomography Protocols with Positivity are Compressed Sensing Protocols (Open Access)

    DTIC Science & Technology

    2015-12-08

    ARTICLE OPEN Quantum tomography protocols with positivity are compressed sensing protocols Amir Kalev1, Robert L Kosut2 and Ivan H Deutsch1...Characterising complex quantum systems is a vital task in quantum information science. Quantum tomography, the standard tool used for this purpose, uses a well...designed measurement record to reconstruct quantum states and processes. It is, however, notoriously inefficient. Recently, the classical signal

  14. A kind of universal quantum secret sharing protocol

    NASA Astrophysics Data System (ADS)

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-01

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.

  15. A kind of universal quantum secret sharing protocol.

    PubMed

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-12

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.

  16. A kind of universal quantum secret sharing protocol

    PubMed Central

    Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian

    2017-01-01

    Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix. PMID:28079109

  17. [Computerized clinical protocol for occlusion].

    PubMed

    Salsench, J; Ferrer, J; Nogueras, J

    1988-11-01

    In making a protocol it is necessary that all members of the team who are going to collect information have the same unity of criterion about the different variables that compose it. The drawing up of this document is as much or more necessary than the protocol itself. In this work we all data collected in the protocol and we give the explanations of each concept.

  18. Families of quantum fingerprinting protocols

    NASA Astrophysics Data System (ADS)

    Lovitz, Benjamin; Lütkenhaus, Norbert

    2018-03-01

    We introduce several families of quantum fingerprinting protocols to evaluate the equality function on two n -bit strings in the simultaneous message passing model. The original quantum fingerprinting protocol uses a tensor product of a small number of O (logn ) -qubit high-dimensional signals [H. Buhrman et al., Phys. Rev. Lett. 87, 167902 (2001), 10.1103/PhysRevLett.87.167902], whereas a recently proposed optical protocol uses a tensor product of O (n ) single-qubit signals, while maintaining the O (logn ) information leakage of the original protocol [J. M. Arazola and N. Lütkenhaus, Phys. Rev. A 89, 062305 (2014), 10.1103/PhysRevA.89.062305]. We find a family of protocols which interpolate between the original and optical protocols while maintaining the O (logn ) information leakage, thus demonstrating a tradeoff between the number of signals sent and the dimension of each signal. There has been interest in experimental realization of the recently proposed optical protocol using coherent states [F. Xu et al., Nat. Commun. 6, 8735 (2015), 10.1038/ncomms9735; J.-Y. Guan et al., Phys. Rev. Lett. 116, 240502 (2016), 10.1103/PhysRevLett.116.240502], but as the required number of laser pulses grows linearly with the input size n , eventual challenges for the long-time stability of experimental setups arise. We find a coherent state protocol which reduces the number of signals by a factor 1/2 while also reducing the information leakage. Our reduction makes use of a simple modulation scheme in optical phase space, and we find that more complex modulation schemes are not advantageous. Using a similar technique, we improve a recently proposed coherent state protocol for evaluating the Euclidean distance between two real unit vectors [N. Kumar et al., Phys. Rev. A 95, 032337 (2017), 10.1103/PhysRevA.95.032337] by reducing the number of signals by a factor 1/2 and also reducing the information leakage.

  19. Effectiveness of oxaliplatin desensitization protocols.

    PubMed

    Cortijo-Cascajares, Susana; Nacle-López, Inmaculada; García-Escobar, Ignacio; Aguilella-Vizcaíno, María José; Herreros-de-Tejada, Alberto; Cortés-Funes Castro, Hernán; Calleja-Hernández, Miguel-Ángel

    2013-03-01

    Hypersensitivity reaction (HSR) to antineoplastic drugs can force doctors to stop treatment and seek other alternatives. These alternatives may be less effective, not as well tolerated and/or more expensive. Another option is to use desensitization protocols that induce a temporary state of tolerance by gradually administering small quantities of the antineoplastic drug until the therapeutic dosage is reached. The aim of this study is to assess the effectiveness of oxaliplatin desensitization protocols. A retrospective observational study was carried out between January 2006 and May 2011. The inclusion criteria were patients undergoing chemotherapy treatment with oxaliplatin who had developed an HSR to the drug and who were candidates for continuing the treatment using a desensitization protocol. The patients' clinical records were reviewed and variables were gathered relating to the patient, the treatment, the HSR, and the desensitization protocol administered. The data were analysed using version 18.0 of the statistics program SPSS. A total of 53 desensitization protocols were administered to 21 patients. In 89 % of these cases, no new reactions occurred while the drug was being administered. New reactions of mild severity only occurred in 11 % of cases, and none of these reactions were severe enough for treatment to be stopped. All patients were able to complete the desensitization protocol. This study confirms that oxaliplatin desensitization protocols are safe and effective and allow patients to continue with the treatment that initially caused an HSR.

  20. Strengthened IAEA Safeguards-Imagery Analysis: Geospatial Tools for Nonproliferation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pabian, Frank V

    2012-08-14

    This slide presentation focuses on the growing role and importance of imagery analysis for IAEA safeguards applications and how commercial satellite imagery, together with the newly available geospatial tools, can be used to promote 'all-source synergy.' As additional sources of openly available information, satellite imagery in conjunction with the geospatial tools can be used to significantly augment and enhance existing information gathering techniques, procedures, and analyses in the remote detection and assessment of nonproliferation relevant activities, facilities, and programs. Foremost of the geospatial tools are the 'Digital Virtual Globes' (i.e., GoogleEarth, Virtual Earth, etc.) that are far better than previouslymore » used simple 2-D plan-view line drawings for visualization of known and suspected facilities of interest which can be critical to: (1) Site familiarization and true geospatial context awareness; (2) Pre-inspection planning; (3) Onsite orientation and navigation; (4) Post-inspection reporting; (5) Site monitoring over time for changes; (6) Verification of states site declarations and for input to State Evaluation reports; and (7) A common basis for discussions among all interested parties (Member States). Additionally, as an 'open-source', such virtual globes can also provide a new, essentially free, means to conduct broad area search for undeclared nuclear sites and activities - either alleged through open source leads; identified on internet BLOGS and WIKI Layers, with input from a 'free' cadre of global browsers and/or by knowledgeable local citizens (a.k.a.: 'crowdsourcing'), that can include ground photos and maps; or by other initiatives based on existing information and in-house country knowledge. They also provide a means to acquire ground photography taken by locals, hobbyists, and tourists of the surrounding locales that can be useful in identifying and discriminating between relevant and non-relevant facilities and their

  1. Developing family planning nurse practitioner protocols.

    PubMed

    Hawkins, J W; Roberto, D

    1984-01-01

    This article focuses on the process of development of protocols for family planning nurse practitioners. A rationale for the use of protocols, a definition of the types and examples, and the pros and cons of practice with protocols are presented. A how-to description for the development process follows, including methods and a suggested tool for critique and evaluation. The aim of the article is to assist nurse practitioners in developing protocols for their practice.

  2. Protocol Coordinator | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID), Clinical Center (CC), National Institute of Heart, Lung and Blood Institute (NHLBI), National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), National Center for Advancing Translational Sciences (NCATS), National Institute of Neurological Disorders and Stroke (NINDS), and the National Institute of Mental Health (NIMH). Since its inception in 2001, CMRP’s ability to provide rapid responses, high-quality solutions, and to recruit and retain experts with a variety of backgrounds to meet the growing research portfolios of NCI, NIAID, CC, NHLBI, NIAMS, NCATS, NINDS, and NIMH has led to the considerable expansion of the program and its repertoire of support services. CMRP’s support services are strategically aligned with the program’s mission to provide comprehensive, dedicated support to assist National Institutes of Health researchers in providing the highest quality of clinical research in compliance with applicable regulations and guidelines, maintaining data integrity, and protecting human subjects. For the scientific advancement of clinical research, CMRP services include comprehensive clinical trials, regulatory, pharmacovigilance, protocol navigation and development, and programmatic and project management support for facilitating the conduct of 400+ Phase I, II, and III domestic and international trials on a yearly basis. These trials investigate the prevention, diagnosis, treatment of, and therapies for cancer, influenza, HIV, and other infectious diseases and viruses such as hepatitis C, tuberculosis, malaria, and Ebola virus; heart, lung, and

  3. IAEA Co-ordinated Research Project: update of X-ray and gamma-ray decay data standards for detector calibration and other applications.

    PubMed

    Nichols, Alan L

    2004-01-01

    A Co-ordinated Research Project (CRP) was established in 1998 by the IAEA Nuclear Data Section (Update of X-ray and gamma-ray Decay Data Standards for Detector Calibration and Other Applications), in order to improve further the recommended decay data used to undertake efficiency calibrations of gamma-ray detectors. Participants in this CRP reviewed and modified the list of radionuclides most suited for detector efficiency calibration, and also considered the decay-data needs for safeguards, waste management, dosimetry, nuclear medicine, material analysis and environmental monitoring. Overall, 62 radionuclides were selected for decay-data evaluation, along with four parent-daughter combinations and two natural decay chains. gamma-ray emissions from specific nuclear reactions were also included to extend the calibrant energy well beyond 10 MeV. A significant number of these decay-data evaluations have been completed, and an IAEA-TECDOC report and database are in the process of being assembled for planned completion by the end of 2003.

  4. In Vivo, Non-Invasive Characterization of Human Bone by Hybrid Broadband (600-1200 nm) Diffuse Optical and Correlation Spectroscopies

    PubMed Central

    Pagliazzi, Marco; Negredo, Eugènia; Martelli, Fabrizio; Farina, Andrea; Dalla Mora, Alberto; Lindner, Claus; Farzam, Parisa; Pérez-Álvarez, Núria; Puig, Jordi; Taroni, Paola; Pifferi, Antonio; Durduran, Turgut

    2016-01-01

    Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care. PMID:27997565

  5. National Sample Assessment Protocols

    ERIC Educational Resources Information Center

    Ministerial Council on Education, Employment, Training and Youth Affairs (NJ1), 2012

    2012-01-01

    These protocols represent a working guide for planning and implementing national sample assessments in connection with the national Key Performance Measures (KPMs). The protocols are intended for agencies involved in planning or conducting national sample assessments and personnel responsible for administering associated tenders or contracts,…

  6. On the status of IAEA delta-13C stable isotope reference materials.

    NASA Astrophysics Data System (ADS)

    Assonov, Sergey; Groening, Manfred; Fajgelj, Ales

    2016-04-01

    For practical reasons all isotope measurements are performed on relative scales realized through the use of international, scale-defining primary standards. In fact these standards were materials (artefacts, similar to prototypes of meter and kg) selected based on their properties. The VPDB delta-13C scale is realised via two highest-level reference materials NBS19 and LSVEC, the first defining the scale and the second aimed to normalise lab-to-lab calibrations. These two reference materials (RMs) have been maintained and distributed by IAEA and NIST. The priority task is to maintain these primary RMs at the required uncertainty level, thus ensuring the long-term scale consistency. The second task is to introduce replacements when needed (currently for exhausted NBS19, work in progress). The next is to produce a family of lower level RMs (secondary, tertiary) addressing needs of various applications (with different delta values, in different physical-chemical forms) and their needs for the uncertainty; these RMs should be traceable to the highest level RMs. Presently three is a need for a range of RMs addressing existing and newly emerging analytical techniques (e.g. optical isotopic analysers) in form of calibrated CO2 gases with different delta-13C values. All that implies creating a family of delta-13C stable isotope reference materials. Presently IAEA works on replacement for NBS19 and planning new RMs. Besides, we found that LSVEC (introduced as second anchor for the VPDB scale in 2006) demonstrate a considerable scatter of its delta-13C value which implies a potential bias of the property value and increased value uncertainty which may conflict with uncertainty requirements for atmospheric monitoring. That is not compatible with the status of LSVEC, and therefore it should be replaced as soon as possible. The presentation will give an overview of the current status, the strategic plan of developments and the near future steps.

  7. Phase Transition in Protocols Minimizing Work Fluctuations

    NASA Astrophysics Data System (ADS)

    Solon, Alexandre P.; Horowitz, Jordan M.

    2018-05-01

    For two canonical examples of driven mesoscopic systems—a harmonically trapped Brownian particle and a quantum dot—we numerically determine the finite-time protocols that optimize the compromise between the standard deviation and the mean of the dissipated work. In the case of the oscillator, we observe a collection of protocols that smoothly trade off between average work and its fluctuations. However, for the quantum dot, we find that as we shift the weight of our optimization objective from average work to work standard deviation, there is an analog of a first-order phase transition in protocol space: two distinct protocols exchange global optimality with mixed protocols akin to phase coexistence. As a result, the two types of protocols possess qualitatively different properties and remain distinct even in the infinite duration limit: optimal-work-fluctuation protocols never coalesce with the minimal-work protocols, which therefore never become quasistatic.

  8. Training set optimization under population structure in genomic selection.

    PubMed

    Isidro, Julio; Jannink, Jean-Luc; Akdemir, Deniz; Poland, Jesse; Heslot, Nicolas; Sorrells, Mark E

    2015-01-01

    Population structure must be evaluated before optimization of the training set population. Maximizing the phenotypic variance captured by the training set is important for optimal performance. The optimization of the training set (TRS) in genomic selection has received much interest in both animal and plant breeding, because it is critical to the accuracy of the prediction models. In this study, five different TRS sampling algorithms, stratified sampling, mean of the coefficient of determination (CDmean), mean of predictor error variance (PEVmean), stratified CDmean (StratCDmean) and random sampling, were evaluated for prediction accuracy in the presence of different levels of population structure. In the presence of population structure, the most phenotypic variation captured by a sampling method in the TRS is desirable. The wheat dataset showed mild population structure, and CDmean and stratified CDmean methods showed the highest accuracies for all the traits except for test weight and heading date. The rice dataset had strong population structure and the approach based on stratified sampling showed the highest accuracies for all traits. In general, CDmean minimized the relationship between genotypes in the TRS, maximizing the relationship between TRS and the test set. This makes it suitable as an optimization criterion for long-term selection. Our results indicated that the best selection criterion used to optimize the TRS seems to depend on the interaction of trait architecture and population structure.

  9. A Security Analysis of the 802.11s Wireless Mesh Network Routing Protocol and Its Secure Routing Protocols

    PubMed Central

    Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo

    2013-01-01

    Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP. PMID:24002231

  10. A security analysis of the 802.11s wireless mesh network routing protocol and its secure routing protocols.

    PubMed

    Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo

    2013-09-02

    Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP.

  11. In-memory interconnect protocol configuration registers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Kevin Y.; Roberts, David A.

    Systems, apparatuses, and methods for moving the interconnect protocol configuration registers into the main memory space of a node. The region of memory used for storing the interconnect protocol configuration registers may also be made cacheable to reduce the latency of accesses to the interconnect protocol configuration registers. Interconnect protocol configuration registers which are used during a startup routine may be prefetched into the host's cache to make the startup routine more efficient. The interconnect protocol configuration registers for various interconnect protocols may include one or more of device capability tables, memory-side statistics (e.g., to support two-level memory data mappingmore » decisions), advanced memory and interconnect features such as repair resources and routing tables, prefetching hints, error correcting code (ECC) bits, lists of device capabilities, set and store base address, capability, device ID, status, configuration, capabilities, and other settings.« less

  12. Physical Therapy Protocols for Arthroscopic Bankart Repair.

    PubMed

    DeFroda, Steven F; Mehta, Nabil; Owens, Brett D

    Outcomes after arthroscopic Bankart repair can be highly dependent on compliance and participation in physical therapy. Additionally, there are many variations in physician-recommended physical therapy protocols. The rehabilitation protocols of academic orthopaedic surgery departments vary widely despite the presence of consensus protocols. Descriptive epidemiology study. Level 3. Web-based arthroscopic Bankart rehabilitation protocols available online from Accreditation Council for Graduate Medical Education (ACGME)-accredited orthopaedic surgery programs were included for review. Individual protocols were reviewed to evaluate for the presence or absence of recommended therapies, goals for completion of ranges of motion, functional milestones, exercise start times, and recommended time to return to sport. Thirty protocols from 27 (16.4%) total institutions were identified out of 164 eligible for review. Overall, 9 (30%) protocols recommended an initial period of strict immobilization. Variability existed between the recommended time periods for sling immobilization (mean, 4.8 ± 1.8 weeks). The types of exercises and their start dates were also inconsistent. Goals to full passive range of motion (mean, 9.2 ± 2.8 weeks) and full active range of motion (mean, 12.2 ± 2.8 weeks) were consistent with other published protocols; however, wide ranges existed within the reviewed protocols as a whole. Only 10 protocols (33.3%) included a timeline for return to sport, and only 3 (10%) gave an estimate for return to game competition. Variation also existed when compared with the American Society of Shoulder and Elbow Therapists' (ASSET) consensus protocol. Rehabilitation protocols after arthroscopic Bankart repair were found to be highly variable. They also varied with regard to published consensus protocols. This discrepancy may lead to confusion among therapists and patients. This study highlights the importance of attending surgeons being very clear and specific with

  13. The Network Protocol Analysis Technique in Snort

    NASA Astrophysics Data System (ADS)

    Wu, Qing-Xiu

    Network protocol analysis is a network sniffer to capture data for further analysis and understanding of the technical means necessary packets. Network sniffing is intercepted by packet assembly binary format of the original message content. In order to obtain the information contained. Required based on TCP / IP protocol stack protocol specification. Again to restore the data packets at protocol format and content in each protocol layer. Actual data transferred, as well as the application tier.

  14. Spacelab system analysis: The modified free access protocol: An access protocol for communication systems with periodic and Poisson traffic

    NASA Technical Reports Server (NTRS)

    Ingels, Frank; Owens, John; Daniel, Steven

    1989-01-01

    The protocol definition and terminal hardware for the modified free access protocol, a communications protocol similar to Ethernet, are developed. A MFA protocol simulator and a CSMA/CD math model are also developed. The protocol is tailored to communication systems where the total traffic may be divided into scheduled traffic and Poisson traffic. The scheduled traffic should occur on a periodic basis but may occur after a given event such as a request for data from a large number of stations. The Poisson traffic will include alarms and other random traffic. The purpose of the protocol is to guarantee that scheduled packets will be delivered without collision. This is required in many control and data collection systems. The protocol uses standard Ethernet hardware and software requiring minimum modifications to an existing system. The modification to the protocol only affects the Ethernet transmission privileges and does not effect the Ethernet receiver.

  15. Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies.

    PubMed

    Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S; Thwaites, David I; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar

    2016-07-01

    The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP 'Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques' was conducted in 2009-2012 as an extension of previously developed audit programs. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing

  16. Incorporating ethical principles into clinical research protocols: a tool for protocol writers and ethics committees

    PubMed Central

    Li, Rebecca H; Wacholtz, Mary C; Barnes, Mark; Boggs, Liam; Callery-D'Amico, Susan; Davis, Amy; Digilova, Alla; Forster, David; Heffernan, Kate; Luthin, Maeve; Lynch, Holly Fernandez; McNair, Lindsay; Miller, Jennifer E; Murphy, Jacquelyn; Van Campen, Luann; Wilenzick, Mark; Wolf, Delia; Woolston, Cris; Aldinger, Carmen; Bierer, Barbara E

    2016-01-01

    A novel Protocol Ethics Tool Kit (‘Ethics Tool Kit’) has been developed by a multi-stakeholder group of the Multi-Regional Clinical Trials Center of Brigham and Women's Hospital and Harvard. The purpose of the Ethics Tool Kit is to facilitate effective recognition, consideration and deliberation of critical ethical issues in clinical trial protocols. The Ethics Tool Kit may be used by investigators and sponsors to develop a dedicated Ethics Section within a protocol to improve the consistency and transparency between clinical trial protocols and research ethics committee reviews. It may also streamline ethics review and may facilitate and expedite the review process by anticipating the concerns of ethics committee reviewers. Specific attention was given to issues arising in multinational settings. With the use of this Tool Kit, researchers have the opportunity to address critical research ethics issues proactively, potentially speeding the time and easing the process to final protocol approval. PMID:26811365

  17. Publication trends of study protocols in rehabilitation.

    PubMed

    Jesus, Tiago S; Colquhoun, Heather L

    2017-09-04

    Growing evidence points for the need to publish study protocols in the health field. To observe whether the growing interest in publishing study protocols in the broader health field has been translated into increased publications of rehabilitation study protocols. Observational study using publication data and its indexation in PubMed. Not applicable. Not applicable. PubMed was searched with appropriate combinations of Medical Subject Headings up to December 2014. The effective presence of study protocols was manually screened. Regression models analyzed the yearly growth of publications. Two-sample Z-tests analyzed whether the proportion of Systematic Reviews (SRs) and Randomized Controlled Trials (RCTs) among study protocols differed from that of the same designs for the broader rehabilitation research. Up to December 2014, 746 publications of rehabilitation study protocols were identified, with an exponential growth since 2005 (r2=0.981; p<0.001). RCT protocols were the most common among rehabilitation study protocols (83%), while RCTs were significantly more prevalent among study protocols than among the broader rehabilitation research (83% vs. 35.8%; p<0.001). For SRs, the picture was reversed: significantly less common among study protocols (2.8% vs. 9.3%; p<0.001). Funding was more often reported by rehabilitation study protocols than the broader rehabilitation research (90% vs. 53.1%; p<0.001). Rehabilitation journals published a significantly lower share of rehabilitation study protocols than they did for the broader rehabilitation research (1.8% vs.16.7%; p<0.001). Identifying the reasons for these discrepancies and reverting unwarranted disparities (e.g. low rate of publication for rehabilitation SR protocols) are likely new avenues for rehabilitation research and its publication. SRs, particularly those aggregating RCT results, are considered the best standard of evidence to guide rehabilitation clinical practice; however, that standard can be improved

  18. Orbitally Tuned C and N Isotopic Records of Aptian Oceanic Anoxic Event1a in Northeastern Mexico and Deep Sea Drilling Project Site 398, North Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Montanez, I. P.; Li, Y.; Osleger, D. A.; Bralower, T. J.

    2006-12-01

    High-resolution and expanded records of early Aptian Oceanic Anoxic Event (OAE) 1a (120 Ma) were recovered from outer shelf and slope deposits from the Sierra Madre Oriental of northeast Mexico and from hemipelagic deposits at Deep Sea Drilling Project Site 398 on Vigo Seamount in the North Atlantic Ocean. OAE1a is recognized in these deposits by minor increases in organic carbon content (up to 2 wt%) and widely-recognized, characteristic δ13Corg and δ13Ccarb variations that record significant changes in global carbon cycling. Here we present continuous dm-scale records of grain size distributions, wt% TOC and carbonate, C/N ratios, and C and N isotopes for these stratigraphically-expanded sections. Our high-resolution rock magnetic study of the same stratigraphic intervals establishes orbital timescales for OAE1a at these sites. The highly expanded records reveal significantly more structure in isotopic and TOC variation throughout OAE1a than contemporaneous condensed deep-sea records. Our data define an initial prominent negative excursion followed by repeated and short-lived (103 to 104 yr) fluctuations and a final interval of near invariant δ13Ccarb and δ13Corg values. Elevated TOC, a significant increase in C/N ratios from background marine values, rapid shifts in C and N isotopic compositions and sustained decoupling of δ13Corg and δ15Norg occur throughout the interval of short- lived isotopic fluctuations. Anhysteretic remanent magnetization (ARM) measurements were used as proxies for terrigenous influx during OAE1a. Spectral analyses of ARM depth series reveal dominant cycles with wavelength ratios resembling those of modern orbital periodicities, implying that orbital variations may have modulated depositional processes. These orbitally tuned geochemical proxy records indicate that the Aptian deposits from northeastern Mexican and Site 398 on Vigo Seamount hold promise for refining phase relationships between geochemical and isotopic proxies

  19. In silico toxicology protocols.

    PubMed

    Myatt, Glenn J; Ahlberg, Ernst; Akahori, Yumi; Allen, David; Amberg, Alexander; Anger, Lennart T; Aptula, Aynur; Auerbach, Scott; Beilke, Lisa; Bellion, Phillip; Benigni, Romualdo; Bercu, Joel; Booth, Ewan D; Bower, Dave; Brigo, Alessandro; Burden, Natalie; Cammerer, Zoryana; Cronin, Mark T D; Cross, Kevin P; Custer, Laura; Dettwiler, Magdalena; Dobo, Krista; Ford, Kevin A; Fortin, Marie C; Gad-McDonald, Samantha E; Gellatly, Nichola; Gervais, Véronique; Glover, Kyle P; Glowienke, Susanne; Van Gompel, Jacky; Gutsell, Steve; Hardy, Barry; Harvey, James S; Hillegass, Jedd; Honma, Masamitsu; Hsieh, Jui-Hua; Hsu, Chia-Wen; Hughes, Kathy; Johnson, Candice; Jolly, Robert; Jones, David; Kemper, Ray; Kenyon, Michelle O; Kim, Marlene T; Kruhlak, Naomi L; Kulkarni, Sunil A; Kümmerer, Klaus; Leavitt, Penny; Majer, Bernhard; Masten, Scott; Miller, Scott; Moser, Janet; Mumtaz, Moiz; Muster, Wolfgang; Neilson, Louise; Oprea, Tudor I; Patlewicz, Grace; Paulino, Alexandre; Lo Piparo, Elena; Powley, Mark; Quigley, Donald P; Reddy, M Vijayaraj; Richarz, Andrea-Nicole; Ruiz, Patricia; Schilter, Benoit; Serafimova, Rositsa; Simpson, Wendy; Stavitskaya, Lidiya; Stidl, Reinhard; Suarez-Rodriguez, Diana; Szabo, David T; Teasdale, Andrew; Trejo-Martin, Alejandra; Valentin, Jean-Pierre; Vuorinen, Anna; Wall, Brian A; Watts, Pete; White, Angela T; Wichard, Joerg; Witt, Kristine L; Woolley, Adam; Woolley, David; Zwickl, Craig; Hasselgren, Catrin

    2018-07-01

    The present publication surveys several applications of in silico (i.e., computational) toxicology approaches across different industries and institutions. It highlights the need to develop standardized protocols when conducting toxicity-related predictions. This contribution articulates the information needed for protocols to support in silico predictions for major toxicological endpoints of concern (e.g., genetic toxicity, carcinogenicity, acute toxicity, reproductive toxicity, developmental toxicity) across several industries and regulatory bodies. Such novel in silico toxicology (IST) protocols, when fully developed and implemented, will ensure in silico toxicological assessments are performed and evaluated in a consistent, reproducible, and well-documented manner across industries and regulatory bodies to support wider uptake and acceptance of the approaches. The development of IST protocols is an initiative developed through a collaboration among an international consortium to reflect the state-of-the-art in in silico toxicology for hazard identification and characterization. A general outline for describing the development of such protocols is included and it is based on in silico predictions and/or available experimental data for a defined series of relevant toxicological effects or mechanisms. The publication presents a novel approach for determining the reliability of in silico predictions alongside experimental data. In addition, we discuss how to determine the level of confidence in the assessment based on the relevance and reliability of the information. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  20. The Decremental Protocol as an Alternative Protocol to Measure Maximal Oxygen Consumption in Athletes.

    PubMed

    Taylor, Katrina; Seegmiller, Jeffrey; Vella, Chantal A

    2016-11-01

    To determine whether a decremental protocol could elicit a higher maximal oxygen consumption (VO 2 max) than an incremental protocol in trained participants. A secondary aim was to examine whether cardiac-output (Q) and stroke-volume (SV) responses differed between decremental and incremental protocols in this sample. Nineteen runners/triathletes were randomized to either the decremental or incremental group. All participants completed an initial incremental VO 2 max test on a treadmill, followed by a verification phase. The incremental group completed 2 further incremental tests. The decremental group completed a second VO 2 max test using the decremental protocol, based on their verification phase. The decremental group then completed a final incremental test. During each test, VO 2 , ventilation, and heart rate were measured, and cardiac variables were estimated with thoracic bioimpedance. Repeated-measures analysis of variance was conducted with an alpha level set at .05. There were no significant main effects for group (P = .37) or interaction (P = .10) over time (P = .45). VO 2 max was similar between the incremental (57.29 ± 8.94 mL · kg -1 · min -1 ) and decremental (60.82 ± 8.49 mL · kg -1 · min -1 ) groups over time. Furthermore, Q and SV were similar between the incremental (Q 22.72 ± 5.85 L/min, SV 119.64 ± 33.02 mL/beat) and decremental groups (Q 20.36 ± 4.59 L/min, SV 109.03 ± 24.27 mL/beat) across all 3 trials. The findings suggest that the decremental protocol does not elicit higher VO 2 max than an incremental protocol but may be used as an alternative protocol to measure VO 2 max in runners and triathletes.

  1. 70 FR 69562 - Office of Environmental Information; Request for Comment and Request for Information on System...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2005-11-16

    ... Reference System (TRS) [see http://www.epa.gov/trs ] in order to better support future semantic Web needs... creation of glossaries for Web pages and documents, a common vocabulary for search engines, and in the...

  2. Instructor Handbook for the Protocol Modules on Classroom Management. Utah Protocol Materials Project.

    ERIC Educational Resources Information Center

    Langer, Philip; Borg, Walter R.

    This handbook is designed to acquaint the teacher educator with the training materials in classroom management prepared by the Utah State University Protocol Training Project. It deals with the protocol materials generally and with each module specifically, and includes the following sections: (a) an introduction to and rationale for protocol…

  3. Standards for Environmental Measurement Using GIS: Toward a Protocol for Protocols.

    PubMed

    Forsyth, Ann; Schmitz, Kathryn H; Oakes, Michael; Zimmerman, Jason; Koepp, Joel

    2006-02-01

    Interdisciplinary research regarding how the built environment influences physical activity has recently increased. Many research projects conducted jointly by public health and environmental design professionals are using geographic information systems (GIS) to objectively measure the built environment. Numerous methodological issues remain, however, and environmental measurements have not been well documented with accepted, common definitions of valid, reliable variables. This paper proposes how to create and document standardized definitions for measures of environmental variables using GIS with the ultimate goal of developing reliable, valid measures. Inherent problems with software and data that hamper environmental measurement can be offset by protocols combining clear conceptual bases with detailed measurement instructions. Examples demonstrate how protocols can more clearly translate concepts into specific measurement. This paper provides a model for developing protocols to allow high quality comparative research on relationships between the environment and physical activity and other outcomes of public health interest.

  4. 21 CFR 1301.18 - Research protocols.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 9 2014-04-01 2014-04-01 false Research protocols. 1301.18 Section 1301.18 Food..., DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Registration § 1301.18 Research protocols. (a) A protocol to conduct research with controlled substances listed in Schedule I shall be in the following form...

  5. 21 CFR 1301.18 - Research protocols.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Research protocols. 1301.18 Section 1301.18 Food..., DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Registration § 1301.18 Research protocols. (a) A protocol to conduct research with controlled substances listed in Schedule I shall be in the following form...

  6. 21 CFR 1301.18 - Research protocols.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Research protocols. 1301.18 Section 1301.18 Food..., DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Registration § 1301.18 Research protocols. (a) A protocol to conduct research with controlled substances listed in Schedule I shall be in the following form...

  7. 21 CFR 1301.18 - Research protocols.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 9 2013-04-01 2013-04-01 false Research protocols. 1301.18 Section 1301.18 Food..., DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Registration § 1301.18 Research protocols. (a) A protocol to conduct research with controlled substances listed in Schedule I shall be in the following form...

  8. 21 CFR 1301.18 - Research protocols.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 9 2012-04-01 2012-04-01 false Research protocols. 1301.18 Section 1301.18 Food..., DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Registration § 1301.18 Research protocols. (a) A protocol to conduct research with controlled substances listed in Schedule I shall be in the following form...

  9. Short Review on Quantum Key Distribution Protocols.

    PubMed

    Giampouris, Dimitris

    2017-01-01

    Cryptographic protocols and mechanisms are widely investigated under the notion of quantum computing. Quantum cryptography offers particular advantages over classical ones, whereas in some cases established protocols have to be revisited in order to maintain their functionality. The purpose of this paper is to provide the basic definitions and review the most important theoretical advancements concerning the BB84 and E91 protocols. It also aims to offer a summary on some key developments on the field of quantum key distribution, closely related with the two aforementioned protocols. The main goal of this study is to provide the necessary background information along with a thorough review on the theoretical aspects of QKD, concentrating on specific protocols. The BB84 and E91 protocols have been chosen because most other protocols are similar to these, a fact that makes them important for the general understanding of how the QKD mechanism functions.

  10. Prosthesis Prescription Protocol of the Arm (PPP-Arm): The implementation of a national prosthesis prescription protocol.

    PubMed

    Wijdenes, Paula; Brouwers, Michael; van der Sluis, Corry K

    2018-02-01

    In order to create more uniformity in the prescription of upper limb prostheses by Dutch rehabilitation teams, the development and implementation of a Prosthesis Prescription Protocol of the upper limb (PPP-Arm) was initiated. The aim was to create a national digital protocol to structure, underpin, and evaluate the prescription of upper limb prostheses for clients with acquired or congenital arm defects. Prosthesis Prescription Protocol of the Arm (PPP-Arm) was developed on the basis of the International Classification of Functioning and consisted of several layers. All stakeholders (rehabilitation teams, orthopedic workshops, patients, and insurance companies) were involved in development and implementation. A national project coordinator and knowledge brokers in each team were essential for the project. PPP-Arm was successfully developed and implemented in nine Dutch rehabilitation teams. The protocol improved team collaboration, structure, and completeness of prosthesis prescriptions and treatment uniformity and might be interesting for other countries as well. Clinical relevance A national protocol to prescribe upper limb prostheses can be helpful to create uniformity in treatment of patients with upper limb defects. Such a protocol improves quality of care for all patients in the country.

  11. An in silico method to identify computer-based protocols worthy of clinical study: An insulin infusion protocol use case

    PubMed Central

    Wong, Anthony F; Pielmeier, Ulrike; Haug, Peter J; Andreassen, Steen

    2016-01-01

    Objective Develop an efficient non-clinical method for identifying promising computer-based protocols for clinical study. An in silico comparison can provide information that informs the decision to proceed to a clinical trial. The authors compared two existing computer-based insulin infusion protocols: eProtocol-insulin from Utah, USA, and Glucosafe from Denmark. Materials and Methods The authors used eProtocol-insulin to manage intensive care unit (ICU) hyperglycemia with intravenous (IV) insulin from 2004 to 2010. Recommendations accepted by the bedside clinicians directly link the subsequent blood glucose values to eProtocol-insulin recommendations and provide a unique clinical database. The authors retrospectively compared in silico 18 984 eProtocol-insulin continuous IV insulin infusion rate recommendations from 408 ICU patients with those of Glucosafe, the candidate computer-based protocol. The subsequent blood glucose measurement value (low, on target, high) was used to identify if the insulin recommendation was too high, on target, or too low. Results Glucosafe consistently provided more favorable continuous IV insulin infusion rate recommendations than eProtocol-insulin for on target (64% of comparisons), low (80% of comparisons), or high (70% of comparisons) blood glucose. Aggregated eProtocol-insulin and Glucosafe continuous IV insulin infusion rates were clinically similar though statistically significantly different (Wilcoxon signed rank test P = .01). In contrast, when stratified by low, on target, or high subsequent blood glucose measurement, insulin infusion rates from eProtocol-insulin and Glucosafe were statistically significantly different (Wilcoxon signed rank test, P < .001), and clinically different. Discussion This in silico comparison appears to be an efficient nonclinical method for identifying promising computer-based protocols. Conclusion Preclinical in silico comparison analytical framework allows rapid and inexpensive

  12. Incorporating ethical principles into clinical research protocols: a tool for protocol writers and ethics committees.

    PubMed

    Li, Rebecca H; Wacholtz, Mary C; Barnes, Mark; Boggs, Liam; Callery-D'Amico, Susan; Davis, Amy; Digilova, Alla; Forster, David; Heffernan, Kate; Luthin, Maeve; Lynch, Holly Fernandez; McNair, Lindsay; Miller, Jennifer E; Murphy, Jacquelyn; Van Campen, Luann; Wilenzick, Mark; Wolf, Delia; Woolston, Cris; Aldinger, Carmen; Bierer, Barbara E

    2016-04-01

    A novel Protocol Ethics Tool Kit ('Ethics Tool Kit') has been developed by a multi-stakeholder group of the Multi-Regional Clinical Trials Center of Brigham and Women's Hospital and Harvard. The purpose of the Ethics Tool Kit is to facilitate effective recognition, consideration and deliberation of critical ethical issues in clinical trial protocols. The Ethics Tool Kit may be used by investigators and sponsors to develop a dedicated Ethics Section within a protocol to improve the consistency and transparency between clinical trial protocols and research ethics committee reviews. It may also streamline ethics review and may facilitate and expedite the review process by anticipating the concerns of ethics committee reviewers. Specific attention was given to issues arising in multinational settings. With the use of this Tool Kit, researchers have the opportunity to address critical research ethics issues proactively, potentially speeding the time and easing the process to final protocol approval. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Nonblocking and orphan free message logging protocols

    NASA Technical Reports Server (NTRS)

    Alvisi, Lorenzo; Hoppe, Bruce; Marzullo, Keith

    1992-01-01

    Currently existing message logging protocols demonstrate a classic pessimistic vs. optimistic tradeoff. We show that the optimistic-pessimistic tradeoff is not inherent to the problem of message logging. We construct a message-logging protocol that has the positive features of both optimistic and pessimistic protocol: our protocol prevents orphans and allows simple failure recovery; however, it requires no blocking in failure-free runs. Furthermore, this protocol does not introduce any additional message overhead as compared to one implemented for a system in which messages may be lost but processes do not crash.

  14. Nonblocking and orphan free message logging protocols

    NASA Astrophysics Data System (ADS)

    Alvisi, Lorenzo; Hoppe, Bruce; Marzullo, Keith

    1992-12-01

    Currently existing message logging protocols demonstrate a classic pessimistic vs. optimistic tradeoff. We show that the optimistic-pessimistic tradeoff is not inherent to the problem of message logging. We construct a message-logging protocol that has the positive features of both optimistic and pessimistic protocol: our protocol prevents orphans and allows simple failure recovery; however, it requires no blocking in failure-free runs. Furthermore, this protocol does not introduce any additional message overhead as compared to one implemented for a system in which messages may be lost but processes do not crash.

  15. The Quantum Steganography Protocol via Quantum Noisy Channels

    NASA Astrophysics Data System (ADS)

    Wei, Zhan-Hong; Chen, Xiu-Bo; Niu, Xin-Xin; Yang, Yi-Xian

    2015-08-01

    As a promising branch of quantum information hiding, Quantum steganography aims to transmit secret messages covertly in public quantum channels. But due to environment noise and decoherence, quantum states easily decay and change. Therefore, it is very meaningful to make a quantum information hiding protocol apply to quantum noisy channels. In this paper, we make the further research on a quantum steganography protocol for quantum noisy channels. The paper proved that the protocol can apply to transmit secret message covertly in quantum noisy channels, and explicity showed quantum steganography protocol. In the protocol, without publishing the cover data, legal receivers can extract the secret message with a certain probability, which make the protocol have a good secrecy. Moreover, our protocol owns the independent security, and can be used in general quantum communications. The communication, which happen in our protocol, do not need entangled states, so our protocol can be used without the limitation of entanglement resource. More importantly, the protocol apply to quantum noisy channels, and can be used widely in the future quantum communication.

  16. A comparative study of 129I content in environmental standard materials IAEA-375, NIST SRM 4354 and NIST SRM 4357 by Thermal Ionization Mass Spectrometry and Accelerator Mass Spectrometry.

    PubMed

    Olson, John; Adamic, Mary; Snyder, Darin; Brookhart, Jacob; Hahn, Paula; Watrous, Matthew

    2017-08-01

    Iodine environmental measurements have consistently been validated in the literature using the standard material IAEA-375, soil collected approximately 160 miles northeast of Chernobyl, which is currently the only soil/sediment material with a certified 129 I activity. IAEA-375 has not been available for purchase since approximately 2010. Two other standard materials that are available (NIST SRM 4354, freshwater lake sediment and NIST SRM 4357, ocean sediment) have certified activities for a variety of radionuclides but not for 129 I. This paper reports a comparison of TIMS and AMS data for all three standards. Copyright © 2017. Published by Elsevier Ltd.

  17. The Effectiveness of Bacteriophages against Methicillin-Resistant Staphylococcus aureus ST398 Nasal Colonization in Pigs.

    PubMed

    Verstappen, Koen M; Tulinski, Pawel; Duim, Birgitta; Fluit, Ad C; Carney, Jennifer; van Nes, Arie; Wagenaar, Jaap A

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important colonizer in animals and an opportunistic pathogen in humans. In humans, MRSA can cause infections that might be difficult to treat because of antimicrobial resistance. The use of bacteriophages has been suggested as a potential approach for the control of MRSA colonization to minimize the-often occupational-exposure of humans. The aim of this study was to assess the efficacy of bacteriophage treatment on porcine nasal colonization with MRSA in vitro, in vivo, and ex vivo. The effectiveness of a bacteriophage combination of phage K*710 and P68 was assessed in vitro by incubating them with MRSA V0608892/1 (ST398) measuring the OD600 hourly. To study the in vivo effect, bacteriophages were administered in a gel developed for human application, which contain 109 plaque-forming units (pfu)/mL (K and P68 in a 19.25:1 ratio) for 5 days to piglets (N = 8) that were experimentally colonized with the MRSA strain. Eight piglets experimentally colonized were used as a negative control. The MRSA strain was also used to colonize porcine nasal mucosa explants and bacteriophages were applied to assess the ex vivo efficacy of treatment. Bacteriophages were effective in vitro. In vivo, sixteen piglets were colonized with MRSA but the number of CFU recovered after the application of the bacteriophages in 8 piglets was not reduced compared to the control animals (approx. 105 CFU/swab). In the ex vivo model, 108 CFU were used to establish colonization with MRSA; a reduction of colonization was not observed after application of bacteriophages. However, application of mupirocin both in vivo and ex vivo resulted in a near eradication of MRSA. i) The MRSA strain was killed in the presence of the bacteriophages phage K*710 and P68 in vitro. ii) Bacteriophages did not reduce porcine nasal colonization in vivo or ex vivo. Physiological in vivo and ex vivo conditions may explain these observations. Efficacy in the ex vivo

  18. The Effectiveness of Bacteriophages against Methicillin-Resistant Staphylococcus aureus ST398 Nasal Colonization in Pigs

    PubMed Central

    Duim, Birgitta; Fluit, Ad C; Carney, Jennifer; van Nes, Arie; Wagenaar, Jaap A

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important colonizer in animals and an opportunistic pathogen in humans. In humans, MRSA can cause infections that might be difficult to treat because of antimicrobial resistance. The use of bacteriophages has been suggested as a potential approach for the control of MRSA colonization to minimize the—often occupational—exposure of humans. The aim of this study was to assess the efficacy of bacteriophage treatment on porcine nasal colonization with MRSA in vitro, in vivo, and ex vivo. The effectiveness of a bacteriophage combination of phage K*710 and P68 was assessed in vitro by incubating them with MRSA V0608892/1 (ST398) measuring the OD600 hourly. To study the in vivo effect, bacteriophages were administered in a gel developed for human application, which contain 109 plaque-forming units (pfu)/mL (K and P68 in a 19.25:1 ratio) for 5 days to piglets (N = 8) that were experimentally colonized with the MRSA strain. Eight piglets experimentally colonized were used as a negative control. The MRSA strain was also used to colonize porcine nasal mucosa explants and bacteriophages were applied to assess the ex vivo efficacy of treatment. Bacteriophages were effective in vitro. In vivo, sixteen piglets were colonized with MRSA but the number of CFU recovered after the application of the bacteriophages in 8 piglets was not reduced compared to the control animals (approx. 105 CFU/swab). In the ex vivo model, 108 CFU were used to establish colonization with MRSA; a reduction of colonization was not observed after application of bacteriophages. However, application of mupirocin both in vivo and ex vivo resulted in a near eradication of MRSA. In conclusion: i) The MRSA strain was killed in the presence of the bacteriophages phage K*710 and P68 in vitro. ii) Bacteriophages did not reduce porcine nasal colonization in vivo or ex vivo. Physiological in vivo and ex vivo conditions may explain these observations. Efficacy

  19. Development of an HPV Educational Protocol for Adolescents

    PubMed Central

    Wetzel, Caitlin; Tissot, Abbigail; Kollar, Linda M.; Hillard, Paula A.; Stone, Rachel; Kahn, Jessica A.

    2007-01-01

    Study Objectives To develop an educational protocol about HPV and Pap tests for adolescents, to evaluate the protocol for understandability and clarity, and to evaluate the protocol for its effectiveness in increasing knowledge about HPV. Design In phase 1, investigators and adolescents developed the protocol. In phase 2, adolescents evaluated the protocol qualitatively, investigators evaluated its effectiveness in increasing HPV knowledge in a sample of adolescents, and the protocol was revised. In phase 3, investigators evaluated the effectiveness of the revised protocol in an additional adolescent sample. Setting Urban, hospital-based teen health center. Participants A total of 252 adolescent girls and boys in the three study phases. Main Outcome Measures Pre- and post-protocol knowledge about HPV, measured using a 10- or 11-item scale. Results Scores on the HPV knowledge scale increased significantly (p<.0001) among adolescents who participated in phases 2 and 3 after they received the protocol. Initial differences in scores based on race, insurance type and condom use were not noted post-protocol. Conclusion The protocol significantly increased knowledge scores about HPV in this population, regardless of sociodemographic characteristics and risk behaviors. Effective, developmentally appropriate educational protocols about HPV and Pap tests are particularly important in clinical settings as cervical cancer screening guidelines evolve, HPV DNA testing is integrated into screening protocols, and HPV vaccines become available. In-depth, one-on-one education about HPV may also prevent adverse psychosocial responses and promote healthy sexual and Pap screening behaviors in adolescents with abnormal HPV or Pap test results. Synopsis The investigators developed an educational protocol about HPV and Pap tests and evaluated its effectiveness in increasing knowledge about HPV among adolescents. PMID:17868894

  20. Systems-level analysis of cell-specific AQP2 gene expression in renal collecting duct.

    PubMed

    Yu, Ming-Jiun; Miller, R Lance; Uawithya, Panapat; Rinschen, Markus M; Khositseth, Sookkasem; Braucht, Drew W W; Chou, Chung-Lin; Pisitkun, Trairak; Nelson, Raoul D; Knepper, Mark A

    2009-02-17

    We used a systems biology-based approach to investigate the basis of cell-specific expression of the water channel aquaporin-2 (AQP2) in the renal collecting duct. Computational analysis of the 5'-flanking region of the AQP2 gene (Genomatix) revealed 2 conserved clusters of putative transcriptional regulator (TR) binding elements (BEs) centered at -513 bp (corresponding to the SF1, NFAT, and FKHD TR families) and -224 bp (corresponding to the AP2, SRF, CREB, GATA, and HOX TR families). Three other conserved motifs corresponded to the ETS, EBOX, and RXR TR families. To identify TRs that potentially bind to these BEs, we carried out mRNA profiling (Affymetrix) in mouse mpkCCDc14 collecting duct cells, revealing expression of 25 TRs that are also expressed in native inner medullary collecting duct. One showed a significant positive correlation with AQP2 mRNA abundance among mpkCCD subclones (Ets1), and 2 showed a significant negative correlation (Elf1 and an orphan nuclear receptor Nr1h2). Transcriptomic profiling in native proximal tubules (PT), medullary thick ascending limbs (MTAL), and IMCDs from kidney identified 14 TRs (including Ets1 and HoxD3) expressed in the IMCD but not PT or MTAL (candidate AQP2 enhancer roles), and 5 TRs (including HoxA5, HoxA9 and HoxA10) expressed in PT and MTAL but not in IMCD (candidate AQP2 repressor roles). In luciferase reporter assays, overexpression of 3 ETS family TRs transactivated the mouse proximal AQP2 promoter. The results implicate ETS family TRs in cell-specific expression of AQP2 and point to HOX, RXR, CREB and GATA family TRs as playing likely additional roles.

  1. A Simple XML Producer-Consumer Protocol

    NASA Technical Reports Server (NTRS)

    Smith, Warren; Gunter, Dan; Quesnel, Darcy; Biegel, Bryan (Technical Monitor)

    2001-01-01

    There are many different projects from government, academia, and industry that provide services for delivering events in distributed environments. The problem with these event services is that they are not general enough to support all uses and they speak different protocols so that they cannot interoperate. We require such interoperability when we, for example, wish to analyze the performance of an application in a distributed environment. Such an analysis might require performance information from the application, computer systems, networks, and scientific instruments. In this work we propose and evaluate a standard XML-based protocol for the transmission of events in distributed systems. One recent trend in government and academic research is the development and deployment of computational grids. Computational grids are large-scale distributed systems that typically consist of high-performance compute, storage, and networking resources. Examples of such computational grids are the DOE Science Grid, the NASA Information Power Grid (IPG), and the NSF Partnerships for Advanced Computing Infrastructure (PACIs). The major effort to deploy these grids is in the area of developing the software services to allow users to execute applications on these large and diverse sets of resources. These services include security, execution of remote applications, managing remote data, access to information about resources and services, and so on. There are several toolkits for providing these services such as Globus, Legion, and Condor. As part of these efforts to develop computational grids, the Global Grid Forum is working to standardize the protocols and APIs used by various grid services. This standardization will allow interoperability between the client and server software of the toolkits that are providing the grid services. The goal of the Performance Working Group of the Grid Forum is to standardize protocols and representations related to the storage and distribution of

  2. Three-step semiquantum secure direct communication protocol

    NASA Astrophysics Data System (ADS)

    Zou, XiangFu; Qiu, DaoWen

    2014-09-01

    Quantum secure direct communication is the direct communication of secret messages without need for establishing a shared secret key first. In the existing schemes, quantum secure direct communication is possible only when both parties are quantum. In this paper, we construct a three-step semiquantum secure direct communication (SQSDC) protocol based on single photon sources in which the sender Alice is classical. In a semiquantum protocol, a person is termed classical if he (she) can measure, prepare and send quantum states only with the fixed orthogonal quantum basis {|0>, |1>}. The security of the proposed SQSDC protocol is guaranteed by the complete robustness of semiquantum key distribution protocols and the unconditional security of classical one-time pad encryption. Therefore, the proposed SQSDC protocol is also completely robust. Complete robustness indicates that nonzero information acquired by an eavesdropper Eve on the secret message implies the nonzero probability that the legitimate participants can find errors on the bits tested by this protocol. In the proposed protocol, we suggest a method to check Eves disturbing in the doves returning phase such that Alice does not need to announce publicly any position or their coded bits value after the photons transmission is completed. Moreover, the proposed SQSDC protocol can be implemented with the existing techniques. Compared with many quantum secure direct communication protocols, the proposed SQSDC protocol has two merits: firstly the sender only needs classical capabilities; secondly to check Eves disturbing after the transmission of quantum states, no additional classical information is needed.

  3. EXACT2: the semantics of biomedical protocols

    PubMed Central

    2014-01-01

    Background The reliability and reproducibility of experimental procedures is a cornerstone of scientific practice. There is a pressing technological need for the better representation of biomedical protocols to enable other agents (human or machine) to better reproduce results. A framework that ensures that all information required for the replication of experimental protocols is essential to achieve reproducibility. Methods We have developed the ontology EXACT2 (EXperimental ACTions) that is designed to capture the full semantics of biomedical protocols required for their reproducibility. To construct EXACT2 we manually inspected hundreds of published and commercial biomedical protocols from several areas of biomedicine. After establishing a clear pattern for extracting the required information we utilized text-mining tools to translate the protocols into a machine amenable format. We have verified the utility of EXACT2 through the successful processing of previously 'unseen' (not used for the construction of EXACT2) protocols. Results The paper reports on a fundamentally new version EXACT2 that supports the semantically-defined representation of biomedical protocols. The ability of EXACT2 to capture the semantics of biomedical procedures was verified through a text mining use case. In this EXACT2 is used as a reference model for text mining tools to identify terms pertinent to experimental actions, and their properties, in biomedical protocols expressed in natural language. An EXACT2-based framework for the translation of biomedical protocols to a machine amenable format is proposed. Conclusions The EXACT2 ontology is sufficient to record, in a machine processable form, the essential information about biomedical protocols. EXACT2 defines explicit semantics of experimental actions, and can be used by various computer applications. It can serve as a reference model for for the translation of biomedical protocols in natural language into a semantically

  4. ESA Venus Entry Probe Study

    NASA Technical Reports Server (NTRS)

    vandenBerg, M. L.; Falkner, P.; Phipps, A.; Underwood, J. C.; Lingard, J. S.; Moorhouse, J.; Kraft, S.; Peacock, A.

    2005-01-01

    The Venus Entry Probe is one of ESA s Technology Reference Studies (TRS). The purpose of the Technology Reference Studies is to provide a focus for the development of strategically important technologies that are of likely relevance for future scientific missions. The aim of the Venus Entry Probe TRS is to study approaches for low cost in-situ exploration of Venus and other planetary bodies with a significant atmosphere. In this paper, the mission objectives and an outline of the mission concept of the Venus Entry Probe TRS are presented.

  5. Validated System for Centralized Grading of Retinopathy of Prematurity: Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) Study.

    PubMed

    Daniel, Ebenezer; Quinn, Graham E; Hildebrand, P Lloyd; Ells, Anna; Hubbard, G Baker; Capone, Antonio; Martin, E Revell; Ostroff, Candace P; Smith, Eli; Pistilli, Maxwell; Ying, Gui-Shuang

    2015-06-01

    Measurable competence derived from comprehensive and advanced training in grading digital images is critical in studies using a reading center to evaluate retinal fundus images from infants at risk for retinopathy of prematurity (ROP). Details of certification for nonphysician trained readers (TRs) have not yet been described. To describe a centralized system for grading ROP digital images by TRs in the Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) Study. Multicenter observational cohort study conducted from July 1, 2010, to June 30, 2014. The TRs were trained by experienced ROP specialists and certified to detect ROP morphology in digital retinal images under supervision of an ophthalmologist reading center director. An ROP reading center was developed with standard hardware, secure Internet access, and customized image viewing software with an electronic grading form. A detailed protocol for grading was developed. Based on results of TR gradings, a computerized algorithm determined whether referral-warranted ROP (RW-ROP; defined as presence of plus disease, zone I ROP, and stage 3 or worse ROP) was present in digital images from infants with birth weight less than 1251 g enrolled from May 25, 2011, through October 31, 2013. Independent double grading was done by the TRs with adjudication of discrepant fields performed by the reading center director. Digital retinal images. Intragrader and intergrader variability and monitoring for temporal drift. Four TRs underwent rigorous training and certification. A total of 5520 image sets were double graded, with 24.5% requiring adjudication for at least 1 component of RW-ROP. For individual RW-ROP components, the adjudication rate was 3.9% for plus disease, 12.4% for zone I ROP, and 16.9% for stage 3 or worse ROP. The weighted κ for intergrader agreement (n = 80 image sets) was 0.72 (95% CI, 0.52-0.93) for RW-ROP, 0.57 (95% CI, 0.37-0.77) for plus disease, 0.43 (95% CI, 0

  6. MR efficiency using automated MRI-desktop eProtocol

    NASA Astrophysics Data System (ADS)

    Gao, Fei; Xu, Yanzhe; Panda, Anshuman; Zhang, Min; Hanson, James; Su, Congzhe; Wu, Teresa; Pavlicek, William; James, Judy R.

    2017-03-01

    MRI protocols are instruction sheets that radiology technologists use in routine clinical practice for guidance (e.g., slice position, acquisition parameters etc.). In Mayo Clinic Arizona (MCA), there are over 900 MR protocols (ranging across neuro, body, cardiac, breast etc.) which makes maintaining and updating the protocol instructions a labor intensive effort. The task is even more challenging given different vendors (Siemens, GE etc.). This is a universal problem faced by all the hospitals and/or medical research institutions. To increase the efficiency of the MR practice, we designed and implemented a web-based platform (eProtocol) to automate the management of MRI protocols. It is built upon a database that automatically extracts protocol information from DICOM compliant images and provides a user-friendly interface to the technologists to create, edit and update the protocols. Advanced operations such as protocol migrations from scanner to scanner and capability to upload Multimedia content were also implemented. To the best of our knowledge, eProtocol is the first MR protocol automated management tool used clinically. It is expected that this platform will significantly improve the radiology operations efficiency including better image quality and exam consistency, fewer repeat examinations and less acquisition errors. These protocols instructions will be readily available to the technologists during scans. In addition, this web-based platform can be extended to other imaging modalities such as CT, Mammography, and Interventional Radiology and different vendors for imaging protocol management.

  7. SPP: A data base processor data communications protocol

    NASA Technical Reports Server (NTRS)

    Fishwick, P. A.

    1983-01-01

    The design and implementation of a data communications protocol for the Intel Data Base Processor (DBP) is defined. The protocol is termed SPP (Service Port Protocol) since it enables data transfer between the host computer and the DBP service port. The protocol implementation is extensible in that it is explicitly layered and the protocol functionality is hierarchically organized. Extensive trace and performance capabilities have been supplied with the protocol software to permit optional efficient monitoring of the data transfer between the host and the Intel data base processor. Machine independence was considered to be an important attribute during the design and implementation of SPP. The protocol source is fully commented and is included in Appendix A of this report.

  8. THE MASTER PROTOCOL CONCEPT

    PubMed Central

    Allegra, Carmen J.

    2015-01-01

    During the past decade, biomedical technologies have undergone an explosive evolution---from the publication of the first complete human genome in 2003, after more than a decade of effort and at a cost of hundreds of millions of dollars---to the present time, where a complete genomic sequence can be available in less than a day and at a small fraction of the cost of the original sequence. The widespread availability of next generation genomic sequencing has opened the door to the development of precision oncology. The need to test multiple new targeted agents both alone and in combination with other targeted therapies, as well as classic cytotoxic agents, demand the development of novel therapeutic platforms (particularly Master Protocols) capable of efficiently and effectively testing multiple targeted agents or targeted therapeutic strategies in relatively small patient subpopulations. Here, we describe the Master Protocol concept, with a focus on the expected gains and complexities of the use of this design. An overview of Master Protocols currently active or in development is provided along with a more extensive discussion of the Lung Master Protocol (Lung-MAP study). PMID:26433553

  9. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill.

    PubMed

    Lichtenstein, Daniel A

    2015-06-01

    This review article describes two protocols adapted from lung ultrasound: the bedside lung ultrasound in emergency (BLUE)-protocol for the immediate diagnosis of acute respiratory failure and the fluid administration limited by lung sonography (FALLS)-protocol for the management of acute circulatory failure. These applications require the mastery of 10 signs indicating normal lung surface (bat sign, lung sliding, A-lines), pleural effusions (quad and sinusoid sign), lung consolidations (fractal and tissue-like sign), interstitial syndrome (lung rockets), and pneumothorax (stratosphere sign and the lung point). These signs have been assessed in adults, with diagnostic accuracies ranging from 90% to 100%, allowing consideration of ultrasound as a reasonable bedside gold standard. In the BLUE-protocol, profiles have been designed for the main diseases (pneumonia, congestive heart failure, COPD, asthma, pulmonary embolism, pneumothorax), with an accuracy > 90%. In the FALLS-protocol, the change from A-lines to lung rockets appears at a threshold of 18 mm Hg of pulmonary artery occlusion pressure, providing a direct biomarker of clinical volemia. The FALLS-protocol sequentially rules out obstructive, then cardiogenic, then hypovolemic shock for expediting the diagnosis of distributive (usually septic) shock. These applications can be done using simple grayscale machines and one microconvex probe suitable for the whole body. Lung ultrasound is a multifaceted tool also useful for decreasing radiation doses (of interest in neonates where the lung signatures are similar to those in adults), from ARDS to trauma management, and from ICUs to points of care. If done in suitable centers, training is the least of the limitations for making use of this kind of visual medicine.

  10. SU-E-T-665: Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldelaijan, S; Alzorkany, F; Moftah, B

    2015-06-15

    Purpose: Depending on the useful dose range in which radiochromic films operate, number of different radiochromic film models have been designed. The impact of different film models on quenching effect for percent depth dose (PDD) measurements in proton beams has been investigated. Methods: Calibrated PTW Markus ionization chamber was used to measure PDD and beam output for 26.5 MeV protons produced by CS30 cyclotron. An aluminum cylinder was added in front of the beam exit serving as a radiation shutter. The measured signal was normalized to a monitor chamber reading and subsequently scaled by ratio of water-to-air stopping powers atmore » given depth, while the effective depth of measurements was scaled by ratios of material-to-water physical densities and CSDA ranges. Output was measured in water at 2.1 mm reference-depth in the plateau upstream from the Bragg peak. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water. Three radiochromic film models (EBT, EBT3 and HD-V2) were calibrated within Lexan phantom positioned at the same water-equivalent depth. Thicknesses of films sensitive layers were 34 µm, 30 µm and 8 µm, respectively. Small film pieces (1 x 2 cm{sup 2}) were positioned within polyethylene phantom along the beam central axis with an angulation of 5° for PDD measurements. Results: While the output of the proton beam was found to be around 7 Gy/sec, the actual value of the output per monitor chamber reading (2.32 Gy/nC) was used for reference-dose irradiations during film calibration. Dose ratios at the Bragg peak relative to the reference-depth were 3.88, 2.52, 2.19, and 2.02 for the Markus chamber, HD-V2, EBT3, and EBT film models, respectively. Conclusion: Results at hand suggest that quenching effect is reduced when a radiochromic film model with smaller sensitive layer thickness is used for PDD measurements in proton beams. David Lewis is the owner of RCF Consulting, LLC.« less

  11. Quantum-key-distribution protocol with pseudorandom bases

    NASA Astrophysics Data System (ADS)

    Trushechkin, A. S.; Tregubov, P. A.; Kiktenko, E. O.; Kurochkin, Y. V.; Fedorov, A. K.

    2018-01-01

    Quantum key distribution (QKD) offers a way for establishing information-theoretical secure communications. An important part of QKD technology is a high-quality random number generator for the quantum-state preparation and for post-processing procedures. In this work, we consider a class of prepare-and-measure QKD protocols, utilizing additional pseudorandomness in the preparation of quantum states. We study one of such protocols and analyze its security against the intercept-resend attack. We demonstrate that, for single-photon sources, the considered protocol gives better secret key rates than the BB84 and the asymmetric BB84 protocols. However, the protocol strongly requires single-photon sources.

  12. Databases and coordinated research projects at the IAEA on atomic processes in plasmas

    NASA Astrophysics Data System (ADS)

    Braams, Bastiaan J.; Chung, Hyun-Kyung

    2012-05-01

    The Atomic and Molecular Data Unit at the IAEA works with a network of national data centres to encourage and coordinate production and dissemination of fundamental data for atomic, molecular and plasma-material interaction (A+M/PMI) processes that are relevant to the realization of fusion energy. The Unit maintains numerical and bibliographical databases and has started a Wiki-style knowledge base. The Unit also contributes to A+M database interface standards and provides a search engine that offers a common interface to multiple numerical A+M/PMI databases. Coordinated Research Projects (CRPs) bring together fusion energy researchers and atomic, molecular and surface physicists for joint work towards the development of new data and new methods. The databases and current CRPs on A+M/PMI processes are briefly described here.

  13. Databases and coordinated research projects at the IAEA on atomic processes in plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braams, Bastiaan J.; Chung, Hyun-Kyung

    2012-05-25

    The Atomic and Molecular Data Unit at the IAEA works with a network of national data centres to encourage and coordinate production and dissemination of fundamental data for atomic, molecular and plasma-material interaction (A+M/PMI) processes that are relevant to the realization of fusion energy. The Unit maintains numerical and bibliographical databases and has started a Wiki-style knowledge base. The Unit also contributes to A+M database interface standards and provides a search engine that offers a common interface to multiple numerical A+M/PMI databases. Coordinated Research Projects (CRPs) bring together fusion energy researchers and atomic, molecular and surface physicists for joint workmore » towards the development of new data and new methods. The databases and current CRPs on A+M/PMI processes are briefly described here.« less

  14. Reliable multicast protocol specifications protocol operations

    NASA Technical Reports Server (NTRS)

    Callahan, John R.; Montgomery, Todd; Whetten, Brian

    1995-01-01

    This appendix contains the complete state tables for Reliable Multicast Protocol (RMP) Normal Operation, Multi-RPC Extensions, Membership Change Extensions, and Reformation Extensions. First the event types are presented. Afterwards, each RMP operation state, normal and extended, is presented individually and its events shown. Events in the RMP specification are one of several things: (1) arriving packets, (2) expired alarms, (3) user events, (4) exceptional conditions.

  15. Cognitive Protocol Stack Design

    DTIC Science & Technology

    2015-12-30

    SECURITY CLASSIFICATION OF: In the ARO “ Cognitive Protocol Stack Design" project we proposed cognitive networking solutions published in international...areas related to cognitive networking, opening also new lines of research that was not possible to forecast at the beginning of the project. In a...Distribution Unlimited Final Report: Cognitive Protocol Stack Design The views, opinions and/or findings contained in this report are those of the author(s

  16. Detecting Hidden Communications Protocols

    DTIC Science & Technology

    2013-02-11

    Protocols FA9550-09-1-0173 Richard R Brooks Clemson University PO Box 340915 Clemson, SC 29634-0915 Air Force Office of Scientific Research/RSL 875...two botnet detection methods: centralized botnet traffic detection using HMMs and probabilistic context-free grammars (PCFGs) for centralized and...final report for the Detecting Hidden Communications Protocols AFOSR grant with R. R. Brooks form Clemson University as PI. The work funded by the

  17. Training tissue bank operators: the International Atomic Energy Agency (IAEA)/National University of Singapore (NUS) 10 years of experience.

    PubMed

    Nather, A; Phillips, G O; Morales Pedraza, Jorge; Lee, Chris C W

    2009-05-01

    National University of Singapore (NUS) was appointed by IAEA to become IAEA/NUS Regional Training Centre (RTC) for Asia and the Pacific region in September 1996. The Government of Singapore (represented by the Ministry of Environment) with the National Science and Technology Board as the funding agency awarded a grant of S$225,500 to build a new purpose-built tissue bank to be the Regional Training Centre. National University Hospital provided a space of 2,000 square feet for this purpose. The first Diploma Course was launched on 3 November 1997 with 17 candidates with the first NUS Diploma Examination being held in October 1998. Between November 1997 and April 2007, a total of nine courses were conducted by RTC with a total of 180 tissue bank operators, 133 from Asia and the Pacific region (13 countries including 2 from Iran), 14 from Africa (Algeria, Egypt, Libya, Egypt, South Africa and Zambia), 6 from Latin America (Brazil, Chile, Cuba, Peru and Uruguay), 9 from Europe (Greece, Slovakia, Poland, Ukraine) and 2 from Australia. The last batch (ninth batch) involved twenty students registered in April 2007 and will be due to sit for the terminal examination only in April 2008.

  18. A new marine sediment certified reference material (CRM) for the determination of persistent organic contaminants: IAEA-459.

    PubMed

    Tolosa, Imma; Cassi, Roberto; Huertas, David

    2018-04-11

    A new marine sediment certified reference material (IAEA 459) with very low concentrations (μg kg -1 ) for a variety of persistent organic contaminants (POPs) listed by the Stockholm Convention, as well as other POPs and priority substances (PSs) listed in many environmental monitoring programs was developed by the IAEA. The sediment material was collected from the Ham River estuary in South Korea, and the assigned final values were derived from robust statistics on the results provided by selected laboratories which demonstrated technical and quality competence, following the guidance given in ISO Guide 35. The robust mean of the laboratory means was assigned as certified values, for those compounds where the assigned value was derived from at least five datasets and its relative expanded uncertainty was less than 40% of the assigned value (most of the values ranging from 8 to 20%). All the datasets were derived from at least two different analytical techniques which have allowed the assignment of certified concentrations for 22 polychlorinated biphenyl (PCB) congeners, 6 organochlorinated (OC) pesticides, 5 polybrominated diphenyl ethers (PBDEs), and 18 polycyclic aromatic hydrocarbon (PAHs). Mass fractions of compounds that did not fulfill the criteria of certification are considered information values, which include 29 PAHs, 11 PCBs, 16 OC pesticides, and 5 PBDEs. The extensive characterization and associated uncertainties at concentration levels close to the marine sediment quality guidelines will make CRM 459 a valuable matrix reference material for use in marine environmental monitoring programs.

  19. Game-theoretic perspective of Ping-Pong protocol

    NASA Astrophysics Data System (ADS)

    Kaur, Hargeet; Kumar, Atul

    2018-01-01

    We analyse Ping-Pong protocol from the point of view of a game. The analysis helps us in understanding the different strategies of a sender and an eavesdropper to gain the maximum payoff in the game. The study presented here characterizes strategies that lead to different Nash equilibriums. We further demonstrate the condition for Pareto optimality depending on the parameters used in the game. Moreover, we also analysed LM05 protocol and compared it with PP protocol from the point of view of a generic two-way QKD game with or without entanglement. Our results provide a deeper understanding of general two-way QKD protocols in terms of the security and payoffs of different stakeholders in the protocol.

  20. Space Wire Upper Layer Protocols

    NASA Technical Reports Server (NTRS)

    Rakow, Glenn; Schnurr, Richard; Gilley, Daniel; Parkes, Steve

    2004-01-01

    This viewgraph presentation addresses efforts to provide a streamlined approach for developing SpaceWire Upper layer protocols which allows industry to drive standardized communication solutions for real projects. The presentation proposes a simple packet header that will allow flexibility in implementing a diverse range of protocols.

  1. Protocol for a Delay-Tolerant Data-Communication Network

    NASA Technical Reports Server (NTRS)

    Torgerson, Jordan; Hooke, Adrian; Burleigh, Scott; Fall, Kevin

    2004-01-01

    As its name partly indicates, the Delay-Tolerant Networking (DTN) Bundle Protocol is a protocol for delay-tolerant transmission of data via communication networks. This protocol was conceived as a result of studies of how to adapt Internet protocols so that Internet-like services could be provided across interplanetary distances in support of deep-space exploration. The protocol, and software to implement the protocol, is being developed in collaboration among experts at NASA's Jet Propulsion Laboratory and other institutions. No current Internet protocols can accommodate long transmission delay times or intermittent link connectivity. The DTN Bundle Protocol represents a departure from the standard Internet assumption that a continuous path is available from a host computer to a client computer: It provides for routing of data through networks that may be disjointed and may be characterized by long transmission delays. In addition to networks that include deepspace communication links, examples of such networks include terrestrial ones within which branches are temporarily disconnected. The protocol is based partly on the definition of a message-based overlay above the transport layers of the networks on which it is hosted.

  2. 40 CFR 766.14 - Contents of protocols.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Contents of protocols. 766.14 Section 766.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT DIBENZO-PARA-DIOXINS/DIBENZOFURANS General Provisions § 766.14 Contents of protocols. Protocols...

  3. Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies

    PubMed Central

    Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S.; Thwaites, David I.; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar

    2016-01-01

    Abstract The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP ‘Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques’ was conducted in 2009–2012 as an extension of previously developed audit programs. Material and methods. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. Results. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Discussion. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these

  4. Post-upgrade testing on a radiotherapy oncology information system with an embedded record and verify system following the IAEA Human Health Report No. 7 recommendations.

    PubMed

    Nyathi, Thulani; Colyer, Christopher; Bhardwaj, Anup Kumar; Rijken, James; Morton, Jason

    2016-06-01

    Record and verify (R&V) systems have proven that their application in radiotherapy clinics leads to a significant reduction in mis-treatments of patients. The purpose of this technical note is to share our experience of acceptance testing, commissioning and setting up a quality assurance programme for the MOSAIQ® oncology information system and R&V system after upgrading from software version 2.41 to 2.6 in a multi-vendor, multi-site environment. Testing was guided primarily by the IAEA Human Report No. 7 recommendations, but complemented by other departmental workflow specific tests. To the best of our knowledge, this is the first time successful implementation of the IAEA Human Health Report Series No. 7 recommendations have been reported in the literature. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Toilet Phobia and Toilet Refusal In Children.

    PubMed

    Wagner, Catharina; Niemczyk, Justine; von Gontard, Alexander

    2017-01-01

    Objective: Toilet refusal syndrome (TRS) is a common disorder in toddlers, defined by use of diapers and refusal of toilet for defecation, while toilet phobia (TP) is a rare disorder in which toilets are avoided completely. Both disorders have not been described systematically in children, yet. Therefore, the aim was to present typical case vignettes illustrating different clinical presentations of TP and TRS. Methods: 5 typical cases were selected from all patients presented at a specialized outpatient clinic for incontinence at a tertiary university hospital during the last 3 years. Results: The first case is a girl with incontinence and no behavioral comorbidities, for whom treatment was more complicated than expected because of her TP. Second, a boy with an IQ on the border to mild intellectual disability will be presented, who revealed phobias regarding the toilet. Case 3 is exemplary for a group of patients with TRS, who also have ODD and show oppositional behavior in different situations. Cases 4 and 5 show "classical" TRS with constipation following painful defecation. Similarities and differences of TRS and TP, the current state of research, diagnostic and management recommendations are presented in detail. Conclusion: TRS in preschool children is a common condition, associated with high rates of constipation and behavioral problems. In contrast, TP is rarer and harder to recognize for pediatricians, but is often accompanied with somatic and behavioral problems, as well. Although there is a paucity of studies on these pediatric disorders, pediatricians should keep them in mind. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Validation of an algorithm-based definition of treatment resistance in patients with schizophrenia.

    PubMed

    Ajnakina, Olesya; Horsdal, Henriette Thisted; Lally, John; MacCabe, James H; Murray, Robin M; Gasse, Christiane; Wimberley, Theresa

    2018-02-19

    Large-scale pharmacoepidemiological research on treatment resistance relies on accurate identification of people with treatment-resistant schizophrenia (TRS) based on data that are retrievable from administrative registers. This is usually approached by operationalising clinical treatment guidelines by using prescription and hospital admission information. We examined the accuracy of an algorithm-based definition of TRS based on clozapine prescription and/or meeting algorithm-based eligibility criteria for clozapine against a gold standard definition using case notes. We additionally validated a definition entirely based on clozapine prescription. 139 schizophrenia patients aged 18-65years were followed for a mean of 5years after first presentation to psychiatric services in South-London, UK. The diagnostic accuracy of the algorithm-based measure against the gold standard was measured with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of 45 (32.4%) schizophrenia patients met the criteria for the gold standard definition of TRS; applying the algorithm-based definition to the same cohort led to 44 (31.7%) patients fulfilling criteria for TRS with sensitivity, specificity, PPV and NPV of 62.2%, 83.0%, 63.6% and 82.1%, respectively. The definition based on lifetime clozapine prescription had sensitivity, specificity, PPV and NPV of 40.0%, 94.7%, 78.3% and 76.7%, respectively. Although a perfect definition of TRS cannot be derived from available prescription and hospital registers, these results indicate that researchers can confidently use registries to identify individuals with TRS for research and clinical practices. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Distillers by-product cattle diets enhance reduced sulfur gas fluxes from feedlot soils and manures

    USDA-ARS?s Scientific Manuscript database

    Total reduced sulfur (TRS) emissions from animal feeding operations are a concern with increased feeding of high-sulfur distillers by-products. Three feeding trials were conducted to evaluate feeding wet distillers grain plus solubles (WDGS) on TRS fluxes. Fresh manure was collected three times duri...

  8. Probability Distributions over Cryptographic Protocols

    DTIC Science & Technology

    2009-06-01

    Artificial Immune Algorithm . . . . . . . . . . . . . . . . . . . 9 3 Design Decisions 11 3.1 Common Ground...creation algorithm for unbounded distribution . . . . . . . 24 4.2 Message creation algorithm for unbounded naive distribution . . . . 24 4.3 Protocol...creation algorithm for intended-run distributions . . . . . . 26 4.4 Protocol and message creation algorithm for realistic distribution . . 32 ix THIS

  9. Performance of a capillary propellant management device with hydrazine

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.

    1979-01-01

    The propellant management device that was successfully used in the Viking Orbiter spacecraft was selected for the main propulsion system of the Teleoperator Retrieval System (TRS). Due to differences in the missions and different propellants, the operation of this sheet metal vane device required reverification for the TRS application. An analytical investigation was performed considering the adverse acceleration environment and the high contract angle of the hydrazine propellant. Drop tower tests demonstrated that the device would provide propellant acquisition while the TRS was docked with Skylab, but its operation would have to be supplemented through propellant settling when free-flying.

  10. Routing Protocols in Wireless Sensor Networks

    PubMed Central

    Villalba, Luis Javier García; Orozco, Ana Lucila Sandoval; Cabrera, Alicia Triviño; Abbas, Cláudia Jacy Barenco

    2009-01-01

    The applications of wireless sensor networks comprise a wide variety of scenarios. In most of them, the network is composed of a significant number of nodes deployed in an extensive area in which not all nodes are directly connected. Then, the data exchange is supported by multihop communications. Routing protocols are in charge of discovering and maintaining the routes in the network. However, the appropriateness of a particular routing protocol mainly depends on the capabilities of the nodes and on the application requirements. This paper presents a review of the main routing protocols proposed for wireless sensor networks. Additionally, the paper includes the efforts carried out by Spanish universities on developing optimization techniques in the area of routing protocols for wireless sensor networks. PMID:22291515

  11. Technical Analysis of SSP-21 Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bromberger, S.

    As part of the California Energy Systems for the Twenty-First Century (CES-21) program, in December 2016 San Diego Gas and Electric (SDG&E) contracted with Lawrence Livermore National Laboratory (LLNL) to perform an independent verification and validation (IV&V) of a white paper describing their Secure SCADA Protocol for the Twenty-First Century (SSP-21) in order to analyze the effectiveness and propriety of cryptographic protocol use within the SSP-21 specification. SSP-21 is designed to use cryptographic protocols to provide (optional) encryption, authentication, and nonrepudiation, among other capabilities. The cryptographic protocols to be used reflect current industry standards; future versions of SSP-21 will usemore » other advanced technologies to provide a subset of security services.« less

  12. Routing protocols in wireless sensor networks.

    PubMed

    Villalba, Luis Javier García; Orozco, Ana Lucila Sandoval; Cabrera, Alicia Triviño; Abbas, Cláudia Jacy Barenco

    2009-01-01

    The applications of wireless sensor networks comprise a wide variety of scenarios. In most of them, the network is composed of a significant number of nodes deployed in an extensive area in which not all nodes are directly connected. Then, the data exchange is supported by multihop communications. Routing protocols are in charge of discovering and maintaining the routes in the network. However, the appropriateness of a particular routing protocol mainly depends on the capabilities of the nodes and on the application requirements. This paper presents a review of the main routing protocols proposed for wireless sensor networks. Additionally, the paper includes the efforts carried out by Spanish universities on developing optimization techniques in the area of routing protocols for wireless sensor networks.

  13. Distribution of thyroid hormone and thyrotropin receptors in reproductive tissues of adult female rabbits.

    PubMed

    Rodríguez-Castelán, Julia; Anaya-Hernández, Arely; Méndez-Tepepa, Maribel; Martínez-Gómez, Margarita; Castelán, Francisco; Cuevas-Romero, Estela

    2017-02-01

    Thyroid dysfunctions are related to anovulation, miscarriages, and infertility in women and laboratory animals. Mechanisms associated with these effects are unknown, although indirect or direct actions of thyroid hormones and thyrotropin could be assumed. The present study aimed to identify the distribution of thyroid hormones (TRs) and thyrotropin (TSHR) receptors in reproductive organs of female rabbits. Ovary of virgin and pregnant rabbits, as well as the oviduct, uterus, and vagina of virgin rabbits were excised, histologically processed, and cut. Slices from these organs were used for immunohistochemical studies for TRα1-2, TRß1, and TSHR. The presence of TRs and TSHR was found in the primordial, primary, secondary, tertiary, and Graafian follicles of virgin rabbits, as well as in the corpora lutea, corpora albicans, and wall of hemorrhagic cysts of pregnant rabbits. Oviductal regions (fimbria-infundibulum, ampulla, isthmus, and utero-tubal junction), uterus (endometrium and myometrium), and vagina (abdominal, pelvic, and perineal portions) of virgin rabbits showed anti-TRs and anti-TSHR immunoreactivity. Additionally, the distal urethra, paravaginal ganglia, levator ani and iliococcygeus muscles, dorsal nerve and body of the clitoris, perigenital skin, and prostate had TRs and TSHR. The wide presence of TRs and TSHR in female reproductive organs suggests varied effects of thyroid hormones and thyrotropin in reproduction.

  14. Mars Communication Protocols

    NASA Technical Reports Server (NTRS)

    Kazz, G. J.; Greenberg, E.

    2000-01-01

    Over the next decade, international plans and commitments are underway to develop an infrastructure at Mars to support future exploration of the red planet. The purpose of this infrastructure is to provide reliable global communication and navigation coverage for on-approach, landed, roving, and in-flight assets at Mars. The claim is that this infrastructure will: 1) eliminate the need of these assets to carry Direct to Earth (DTE) communications equipment, 2) significantly increase data return and connectivity, 3) enable small mission exploration of Mars without DTE equipment, 4) provide precision navigation i.e., 10 to 100m position resolution, 5) supply timing reference accurate to 10ms. This paper in particular focuses on two CCSDS recommendations for that infrastructure: CCSDS Proximity-1 Space Link Protocol and CCSDS File Delivery Protocol (CFDP). A key aspect of Mars exploration will be the ability of future missions to interoperate. These protocols establish a framework for interoperability by providing standard communication, navigation, and timing services. In addition, these services include strategies to recover gracefully from communication interruptions and interference while ensuring backward compatibility with previous missions from previous phases of exploration.

  15. A Survey on Underwater Acoustic Sensor Network Routing Protocols.

    PubMed

    Li, Ning; Martínez, José-Fernán; Meneses Chaus, Juan Manuel; Eckert, Martina

    2016-03-22

    Underwater acoustic sensor networks (UASNs) have become more and more important in ocean exploration applications, such as ocean monitoring, pollution detection, ocean resource management, underwater device maintenance, etc. In underwater acoustic sensor networks, since the routing protocol guarantees reliable and effective data transmission from the source node to the destination node, routing protocol design is an attractive topic for researchers. There are many routing algorithms have been proposed in recent years. To present the current state of development of UASN routing protocols, we review herein the UASN routing protocol designs reported in recent years. In this paper, all the routing protocols have been classified into different groups according to their characteristics and routing algorithms, such as the non-cross-layer design routing protocol, the traditional cross-layer design routing protocol, and the intelligent algorithm based routing protocol. This is also the first paper that introduces intelligent algorithm-based UASN routing protocols. In addition, in this paper, we investigate the development trends of UASN routing protocols, which can provide researchers with clear and direct insights for further research.

  16. A Survey on Underwater Acoustic Sensor Network Routing Protocols

    PubMed Central

    Li, Ning; Martínez, José-Fernán; Meneses Chaus, Juan Manuel; Eckert, Martina

    2016-01-01

    Underwater acoustic sensor networks (UASNs) have become more and more important in ocean exploration applications, such as ocean monitoring, pollution detection, ocean resource management, underwater device maintenance, etc. In underwater acoustic sensor networks, since the routing protocol guarantees reliable and effective data transmission from the source node to the destination node, routing protocol design is an attractive topic for researchers. There are many routing algorithms have been proposed in recent years. To present the current state of development of UASN routing protocols, we review herein the UASN routing protocol designs reported in recent years. In this paper, all the routing protocols have been classified into different groups according to their characteristics and routing algorithms, such as the non-cross-layer design routing protocol, the traditional cross-layer design routing protocol, and the intelligent algorithm based routing protocol. This is also the first paper that introduces intelligent algorithm-based UASN routing protocols. In addition, in this paper, we investigate the development trends of UASN routing protocols, which can provide researchers with clear and direct insights for further research. PMID:27011193

  17. Protocols for second-generation business satellites systems

    NASA Astrophysics Data System (ADS)

    Evans, B. G.; Coakley, F. P.; El Amin, M. H. M.

    The paper discusses the nature and mix of traffic in business satellite systems and describes the limitations on the protocol imposed by the differing impairments of speech, video, and data. A simple TDMA system protocol is presented which meets the requirements of mixed-service operation. The efficiency of the protocol together with implications for allocation, scheduling and synchronisation are discussed. Future-generation satellites will probably use on-board processing. Some initial work on protocols that make use of on-board processing and the implications for satellite and earth-station equipment are presented.

  18. Processing Protocol for Soil Samples Potentially ...

    EPA Pesticide Factsheets

    Method Operating Procedures This protocol describes the processing steps for 45 g and 9 g soil samples potentially contaminated with Bacillus anthracis spores. The protocol is designed to separate and concentrate the spores from bulk soil down to a pellet that can be used for further analysis. Soil extraction solution and mechanical shaking are used to disrupt soil particle aggregates and to aid in the separation of spores from soil particles. Soil samples are washed twice with soil extraction solution to maximize recovery. Differential centrifugation is used to separate spores from the majority of the soil material. The 45 g protocol has been demonstrated by two laboratories using both loamy and sandy soil types. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol would be robust enough to use at multiple laboratories while achieving comparable recoveries. The 45 g protocol has demonstrated a matrix limit of detection at 14 spores/gram of soil for loamy and sandy soils.

  19. Internet Protocol Implementation Guide.

    DTIC Science & Technology

    1982-08-01

    RD-R153 624 INTERNET PROTOCOL IMPLEMENTATION GIDE(U) SRI 1/2 INTERNATIONAL MENLO PARK CA NETWORK INFORMATION CENTER AUG 82 DCA2e-83-C-8e25 N... INTERNET PROTOCOL S IMPLEMENTATION GUIDE August 1982 DTICFL. !.ECTE .-" MAY 1 31985 ;z B Q.. Network Information Center SRI International Menlo Park...this is more information than the receiving Internet * module needs. The specified procedure is to take the return route recorded in the first

  20. MANAGING UNCERTAINTIES ASSOCIATED WITH RADIOACTIVE WASTE DISPOSAL: TASK GROUP 4 OF THE IAEA PRISM PROJECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seitz, R.

    2011-03-02

    It is widely recognized that the results of safety assessment calculations provide an important contribution to the safety arguments for a disposal facility, but cannot in themselves adequately demonstrate the safety of the disposal system. The safety assessment and a broader range of arguments and activities need to be considered holistically to justify radioactive waste disposal at any particular site. Many programs are therefore moving towards the production of what has become known as a Safety Case, which includes all of the different activities that are conducted to demonstrate the safety of a disposal concept. Recognizing the growing interest inmore » the concept of a Safety Case, the International Atomic Energy Agency (IAEA) is undertaking an intercomparison and harmonization project called PRISM (Practical Illustration and use of the Safety Case Concept in the Management of Near-surface Disposal). The PRISM project is organized into four Task Groups that address key aspects of the Safety Case concept: Task Group 1 - Understanding the Safety Case; Task Group 2 - Disposal facility design; Task Group 3 - Managing waste acceptance; and Task Group 4 - Managing uncertainty. This paper addresses the work of Task Group 4, which is investigating approaches for managing the uncertainties associated with near-surface disposal of radioactive waste and their consideration in the context of the Safety Case. Emphasis is placed on identifying a wide variety of approaches that can and have been used to manage different types of uncertainties, especially non-quantitative approaches that have not received as much attention in previous IAEA projects. This paper includes discussions of the current results of work on the task on managing uncertainty, including: the different circumstances being considered, the sources/types of uncertainties being addressed and some initial proposals for approaches that can be used to manage different types of uncertainties.« less

  1. The Xpress Transfer Protocol (XTP): A tutorial (expanded version)

    NASA Technical Reports Server (NTRS)

    Sanders, Robert M.; Weaver, Alfred C.

    1990-01-01

    The Xpress Transfer Protocol (XTP) is a reliable, real-time, light weight transfer layer protocol. Current transport layer protocols such as DoD's Transmission Control Protocol (TCP) and ISO's Transport Protocol (TP) were not designed for the next generation of high speed, interconnected reliable networks such as fiber distributed data interface (FDDI) and the gigabit/second wide area networks. Unlike all previous transport layer protocols, XTP is being designed to be implemented in hardware as a VLSI chip set. By streamlining the protocol, combining the transport and network layers and utilizing the increased speed and parallelization possible with a VLSI implementation, XTP will be able to provide the end-to-end data transmission rates demanded in high speed networks without compromising reliability and functionality. This paper describes the operation of the XTP protocol and in particular, its error, flow and rate control; inter-networking addressing mechanisms; and multicast support features, as defined in the XTP Protocol Definition Revision 3.4.

  2. Development of a facility for high-precision irradiation of cells with carbon ions.

    PubMed

    van Goethem, Marc-Jan; Niemantsverdriet, Maarten; Brandenburg, Sytze; Langendijk, Johannes A; Coppes, Robert P; van Luijk, Peter

    2011-01-01

    Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed +/-1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell

  3. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prez, L de; Pooter, J de; Jansen, B

    2016-06-15

    Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with amore » new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence

  4. Protocol for Communication Networking for Formation Flying

    NASA Technical Reports Server (NTRS)

    Jennings, Esther; Okino, Clayton; Gao, Jay; Clare, Loren

    2009-01-01

    An application-layer protocol and a network architecture have been proposed for data communications among multiple autonomous spacecraft that are required to fly in a precise formation in order to perform scientific observations. The protocol could also be applied to other autonomous vehicles operating in formation, including robotic aircraft, robotic land vehicles, and robotic underwater vehicles. A group of spacecraft or other vehicles to which the protocol applies could be characterized as a precision-formation- flying (PFF) network, and each vehicle could be characterized as a node in the PFF network. In order to support precise formation flying, it would be necessary to establish a corresponding communication network, through which the vehicles could exchange position and orientation data and formation-control commands. The communication network must enable communication during early phases of a mission, when little positional knowledge is available. Particularly during early mission phases, the distances among vehicles may be so large that communication could be achieved only by relaying across multiple links. The large distances and need for omnidirectional coverage would limit communication links to operation at low bandwidth during these mission phases. Once the vehicles were in formation and distances were shorter, the communication network would be required to provide high-bandwidth, low-jitter service to support tight formation-control loops. The proposed protocol and architecture, intended to satisfy the aforementioned and other requirements, are based on a standard layered-reference-model concept. The proposed application protocol would be used in conjunction with conventional network, data-link, and physical-layer protocols. The proposed protocol includes the ubiquitous Institute of Electrical and Electronics Engineers (IEEE) 802.11 medium access control (MAC) protocol to be used in the datalink layer. In addition to its widespread and proven use in

  5. Coordinated expression and regulation of deiodinases and thyroid hormone receptors during metamorphosis in the Japanese flounder (Paralichthys olivaceus).

    PubMed

    Yu, Jie; Fu, Yuanshuai; Shi, Zhiyi

    2017-04-01

    In vertebrates, thyroid hormone receptors (TRs) and deiodinases are essential for developmental events driven by the thyroid hormones (THs). However, the significance of deiodinases during the metamorphosis of the Japanese flounder (Paralichthys olivaceus) remains unclear. Moreover, regulation and response of the TRs and deiodinases to THs in this fish are poorly understood. Therefore, we detected the expression patterns of THs, deiodinases, and TRs in drug-treated larvae and untreated larvae of P. olivaceus by using enzyme-linked immunosorbent assay and quantitative real-time PCR during P. olivaceus metamorphosis. To further understand the roles of these elements, a rescue assay was performed. Our results show the importance of THs, TRs, and deiodinases in flatfish metamorphosis. Our results also confirm that D1 and D2 activate THs and D3 plays the opposite and complementary role. Moreover, we demonstrated that both TRα and TRβ have important but different roles during P. olivaceus metamorphosis.

  6. Achieving stable remission with maintenance electroconvulsive therapy in a patient with treatment-resistant schizophrenia

    PubMed Central

    Moeller, Sebastian; Kalkwarf, Neele; Lücke, Caroline; Ortiz, Diana; Jahn, Sonja; Först, Christiane; Braun, Niclas; Philipsen, Alexandra; Müller, Helge H.O.

    2017-01-01

    Abstract Rationale: Up to one third of all schizophrenic patients are classified as having treatment-resistant schizophrenia (TRS). This subgroup faces remarkable medical and psychosocial damages, and pharmacotherapy is often limited due to nonresponse and/or side effects. Maintenance electroconvulsive therapy (M-ECT) might be effective in TRS. Patient concerns: We present a case of a 26-year-old male patient with a TRS. Diagnoses: He received a treatment series of ECT sessions and a course of 24 M-ECTs. Interventions: The entire treatment was tolerated without significant side effects. Outcomes: Moreover, the Psychotic Symptom Rating Scale (PSYRATS) scores for both positive and negative symptoms decreased and remained stable over the course of M-ECT. Lessons: Because of the remarkable improvement in the negative and positive symptom clusters, we propose systematic examinations in the field of M-ECT in TRS patients. These studies should integrate long-term outcome and tolerance measurements, gaining insight into the optimal duration of treatment for this indication. PMID:29310360

  7. Achieving stable remission with maintenance electroconvulsive therapy in a patient with treatment-resistant schizophrenia: A case report.

    PubMed

    Moeller, Sebastian; Kalkwarf, Neele; Lücke, Caroline; Ortiz, Diana; Jahn, Sonja; Först, Christiane; Braun, Niclas; Philipsen, Alexandra; Müller, Helge H O

    2017-12-01

    Up to one third of all schizophrenic patients are classified as having treatment-resistant schizophrenia (TRS). This subgroup faces remarkable medical and psychosocial damages, and pharmacotherapy is often limited due to nonresponse and/or side effects. Maintenance electroconvulsive therapy (M-ECT) might be effective in TRS. We present a case of a 26-year-old male patient with a TRS. He received a treatment series of ECT sessions and a course of 24 M-ECTs. The entire treatment was tolerated without significant side effects. Moreover, the Psychotic Symptom Rating Scale (PSYRATS) scores for both positive and negative symptoms decreased and remained stable over the course of M-ECT. Because of the remarkable improvement in the negative and positive symptom clusters, we propose systematic examinations in the field of M-ECT in TRS patients. These studies should integrate long-term outcome and tolerance measurements, gaining insight into the optimal duration of treatment for this indication.

  8. REVIEW OF THE NEGOTIATION OF THE MODEL PROTOCOL ADDITIONAL TO THE AGREEMENT(S) BETWEEN STATE(S) AND THE INTERNATIONAL ATOMIC ENERGY AGENCY FOR THE APPLICATION OF SAFEGUARDS,INFCIRC/540 (Corrected) VOLUME I/III SETTING THE STAGE: 1991-1996.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, M.D.; Saum-Manning, L.; Houck, F.

    Events in Iraq at the beginning of the 1990s demonstrated that the safeguards system of the International Atomic Energy Agency (IAEA) needed to be improved. It had failed, after all, to detect Iraq's clandestine nuclear weapon program even though some of Iraq's's activities had been pursued at inspected facilities in buildings adjacent to ones being inspected by the IAEA. Although there were aspects of the implementation of safeguards where the IAEA needed to improve, the primary limitations were considered to be part of the safeguards system itself. That system was based on the Nuclear Nonproliferation Treaty of 1970, to whichmore » Iraq was a party, and implemented on the basis of a model NPT safeguards agreement, published by the IAEA 1972 as INFCIRC/153 (corrected). The agreement calls for states to accept and for the IAEA to apply safeguards to all nuclear material in the state. Iraq was a party to such an agreement, but it violated the agreement by concealing nuclear material and other nuclear activities from the IAEA. Although the IAEA was inspecting in Iraq, it was hindered by aspects of the agreement that essentially limited its access to points in declared facilities and provided the IAEA with little information about nuclear activities anywhere else in Iraq. As a result, a major review of the NPT safeguards system was initiated by its Director General and Member States with the objective of finding the best means to enable the IAEA to detect both diversions from declared stocks and any undeclared nuclear material or activities in the state. Significant improvements that could be made within existing legal authority were taken quickly, most importantly a change in 1992 in how and when and what design information would be reported to the IAEA. During 1991-1996, the IAEA pursued intensive study, legal and technical analysis, and field trials and held numerous consultations with Member States. The Board of Governors discussed the issue of strengthening

  9. A Self-Stabilizing Synchronization Protocol for Arbitrary Digraphs

    NASA Technical Reports Server (NTRS)

    Malekpour, Mahyar R.

    2011-01-01

    This paper presents a self-stabilizing distributed clock synchronization protocol in the absence of faults in the system. It is focused on the distributed clock synchronization of an arbitrary, non-partitioned digraph ranging from fully connected to 1-connected networks of nodes while allowing for differences in the network elements. This protocol does not rely on assumptions about the initial state of the system, other than the presence of at least one node, and no central clock or a centrally generated signal, pulse, or message is used. Nodes are anonymous, i.e., they do not have unique identities. There is no theoretical limit on the maximum number of participating nodes. The only constraint on the behavior of the node is that the interactions with other nodes are restricted to defined links and interfaces. This protocol deterministically converges within a time bound that is a linear function of the self-stabilization period. We present an outline of a deductive proof of the correctness of the protocol. A bounded model of the protocol was mechanically verified for a variety of topologies. Results of the mechanical proof of the correctness of the protocol are provided. The model checking results have verified the correctness of the protocol as they apply to the networks with unidirectional and bidirectional links. In addition, the results confirm the claims of determinism and linear convergence. As a result, we conjecture that the protocol solves the general case of this problem. We also present several variations of the protocol and discuss that this synchronization protocol is indeed an emergent system.

  10. Mars Sample Handling Protocol Workshop Series: Workshop 4

    NASA Technical Reports Server (NTRS)

    Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)

    2001-01-01

    In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol

  11. Quantum key distribution protocol based on contextuality monogamy

    NASA Astrophysics Data System (ADS)

    Singh, Jaskaran; Bharti, Kishor; Arvind

    2017-06-01

    The security of quantum key distribution (QKD) protocols hinges upon features of physical systems that are uniquely quantum in nature. We explore the role of quantumness, as qualified by quantum contextuality, in a QKD scheme. A QKD protocol based on the Klyachko-Can-Binicioğlu-Shumovsky (KCBS) contextuality scenario using a three-level quantum system is presented. We explicitly show the unconditional security of the protocol by a generalized contextuality monogamy relationship based on the no-disturbance principle. This protocol provides a new framework for QKD which has conceptual and practical advantages over other protocols.

  12. Survey of protocols for the manual segmentation of the hippocampus: preparatory steps towards a joint EADC-ADNI harmonized protocol.

    PubMed

    Boccardi, Marina; Ganzola, Rossana; Bocchetta, Martina; Pievani, Michela; Redolfi, Alberto; Bartzokis, George; Camicioli, Richard; Csernansky, John G; de Leon, Mony J; deToledo-Morrell, Leyla; Killiany, Ronald J; Lehéricy, Stéphane; Pantel, Johannes; Pruessner, Jens C; Soininen, H; Watson, Craig; Duchesne, Simon; Jack, Clifford R; Frisoni, Giovanni B

    2011-01-01

    Manual segmentation from magnetic resonance imaging (MR) is the gold standard for evaluating hippocampal atrophy in Alzheimer's disease (AD). Nonetheless, different segmentation protocols provide up to 2.5-fold volume differences. Here we surveyed the most frequently used segmentation protocols in the AD literature as a preliminary step for international harmonization. The anatomical landmarks (anteriormost and posteriormost slices, superior, inferior, medial, and lateral borders) were identified from 12 published protocols for hippocampal manual segmentation ([Abbreviation] first author, publication year: [B] Bartzokis, 1998; [C] Convit, 1997; [dTM] deToledo-Morrell, 2004; [H] Haller, 1997; [J] Jack, 1994; [K] Killiany, 1993; [L] Lehericy, 1994; [M] Malykhin, 2007; [Pa] Pantel, 2000; [Pr] Pruessner, 2000; [S] Soininen, 1994; [W] Watson, 1992). The hippocampi of one healthy control and one AD patient taken from the 1.5T MR ADNI database were segmented by a single rater according to each protocol. The accuracy of the protocols' interpretation and translation into practice was checked with lead authors of protocols through individual interactive web conferences. Semantically harmonized landmarks and differences were then extracted, regarding: (a) the posteriormost slice, protocol [B] being the most restrictive, and [H, M, Pa, Pr, S] the most inclusive; (b) inclusion [C, dTM, J, L, M, Pr, W] or exclusion [B, H, K, Pa, S] of alveus/fimbria; (c) separation from the parahippocampal gyrus, [C] being the most restrictive, [B, dTM, H, J, Pa, S] the most inclusive. There were no substantial differences in the definition of the anteriormost slice. This survey will allow us to operationalize differences among protocols into tracing units, measure their impact on the repeatability and diagnostic accuracy of manual hippocampal segmentation, and finally develop a harmonized protocol.

  13. Simplified dispatch-assisted CPR instructions outperform standard protocol.

    PubMed

    Dias, J A; Brown, T B; Saini, D; Shah, R C; Cofield, S S; Waterbor, J W; Funkhouser, E; Terndrup, T E

    2007-01-01

    Dispatch-assisted chest compressions only CPR (CC-CPR) has gained widespread acceptance, and recent research suggests that increasing the proportion of compression time during CPR may increase survival from out-of-hospital cardiac arrest. We created a simplified CC-CPR protocol to reduce time to start chest compressions and to increase the proportion of time spent delivering chest compressions. This simplified protocol was compared to a published protocol, Medical Priority Dispatch System (MPDS) Version 11.2, recommended by the National Academies of Emergency Dispatch. Subjects were randomized to the MPDS v11.2 protocol or a simplified protocol. Data was recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions for both protocols. Outcomes included chest compression rate, depth, hand position, full release, overall proportion of compressions without error, time to start of CPR and total hands-off chest time. Proportions were analyzed by Wilcoxon's Rank Sum tests and time variables with Welch ANOVA and Wilcoxon's Rank Sum test. All tests used a two-sided alpha-level of 0.05. One hundred and seventeen subjects were randomized prospectively, 58 to the standard protocol and 59 to the simplified protocol. The average age of subjects in both groups was 25 years old. For both groups, the compression rate was equivalent (104 simplified versus 94 MPDS, p = 0.13), as was the proportion with total release (1.0 simplified versus 1.0 MPDS, p = 0.09). The proportion to the correct depth was greater in the simplified protocol (0.31 versus 0.03, p < 0.01), as was the proportion of compressions done without error (0.05 versus 0.0, p = 0.16). Time to start of chest compressions and total hands-off chest time were better in the simplified protocol (start time 60.9s versus 78.6s, p < 0.0001; hands-off chest time 69 s versus 95 s, p < 0.0001). The proportion with correct hand

  14. Nuclear and isotopic techniques applied to supporting nutritional studies in East Asia and Pacific Countries: IAEA's contributions over 20 years.

    PubMed

    Kim, Seong-Ai; Miranda-da-Cruz, B; Mokhtar, Najat; Iyengar, Venkatesh

    2004-01-01

    The world's scientific community has recognized that isotopic techniques play a vital role in monitoring the effectiveness of nutrition intervention by providing precise data on absorption, bioavailablity and interaction of various micronutrients in a cost effective manner. The International Atomic Energy Agency (IAEA) has been supporting many such health related studies in Member States from developing countries using nuclear and isotopic methods for over 20 years. This report documents the Agency's support for a variety of projects in East Asia and Pacific countries to assess body composition, total energy expenditure, nutrient intake, osteoporosis, infection, vitamin and mineral bioavailability as well as food composition. The IAEA spent a total of 10,302,356 US dollars through Coordinated Research Projects (CRP) and Technical Cooperation Projects (TCP) over the past 20 years. Out of this only 2,732,802, US dollars or 26.5% was used by the East Asia and Pacific countries. While the participation of East Asia and Pacific countries was strong in CRPs and moderate in regional TCPs, they did not participate in national TCPs at all. The non-participation under national TCPs is a serious deficiency when compared with Latin American and African regions and therefore, more participation from the East Asia and Pacific countries in national TCPs is strongly encouraged in the future.

  15. Training set optimization under population structure in genomic selection

    USDA-ARS?s Scientific Manuscript database

    The optimization of the training set (TRS) in genomic selection (GS) has received much interest in both animal and plant breeding, because it is critical to the accuracy of the prediction models. In this study, five different TRS sampling algorithms, stratified sampling, mean of the Coefficient of D...

  16. 77 FR 75894 - Telecommunications Relay Services and Speech-to-Speech Services for Individuals With Hearing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... Individuals With Hearing and Speech Disabilities; E911 Requirements for IP-Enabled Service Providers AGENCY... no uniform numbering system for iTRS services; some iTRS users were reached via an IP address, while...-digit number and his IP address, making it relatively traceable (unlike conventional PSTN spoofing...

  17. Meeting the challenges of global nuclear medicine technologist training in the 21st century: the IAEA Distance Assisted Training (DAT) program.

    PubMed

    Patterson, Heather E; Nunez, Margarita; Philotheou, Geraldine M; Hutton, Brian F

    2013-05-01

    Many countries have made significant investments in nuclear medicine (NM) technology with the acquisition of modern equipment and establishment of facilities, however, often appropriate training is not considered as part of these investments. Training for NM professionals is continually evolving, with a need to meet changing requirements in the workforce. Even places where established higher education courses are available, these do not necessarily cater to the practical component of training and the ever-changing technology that is central to medical imaging. The continuing advances in NM technology and growth of applications in quantitative clinical assessment place increases the pressure on technologists to learn and practice new techniques. Not only is training to understand new concepts limited but often there is inadequate training in the basics of NM and this can be a major constraint to the effective use of the evolving technology. Developing appropriate training programs for the broader international NM community is one of the goals of the International Atomic Energy Agency (IAEA). A particularly successful and relevant development has been the program on 'distance assisted training (DAT) for NM professionals'. The development of DAT was initiated in the 1990s through Australian Government funding, administered under auspices of the IAEA through its Regional Cooperative Agreement, involving most countries in Asia that are Member States of the IAEA. The project has resulted in the development of a set of training modules which are designed for use under direct supervision in the workplace, delivered through means of distance-learning. The program has undergone several revisions and peer reviews with the current version providing a comprehensive training package that is now available online. DAT has been utilized widely in Asia or the Pacific region, Latin America, and parts of Africa and Europe. Currently there are approximately 1000 registered participants

  18. Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    PubMed Central

    Einstein, Andrew J.; Pascual, Thomas N. B.; Mercuri, Mathew; Karthikeyan, Ganesan; Vitola, João V.; Mahmarian, John J.; Better, Nathan; Bouyoucef, Salah E.; Hee-Seung Bom, Henry; Lele, Vikram; Magboo, V. Peter C.; Alexánderson, Erick; Allam, Adel H.; Al-Mallah, Mouaz H.; Flotats, Albert; Jerome, Scott; Kaufmann, Philipp A.; Luxenburg, Osnat; Shaw, Leslee J.; Underwood, S. Richard; Rehani, Madan M.; Kashyap, Ravi; Paez, Diana; Dondi, Maurizio

    2015-01-01

    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing ‘best practices’ worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March–April 2013. Eight ‘best practices’ relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more ‘best practices’ had lower EDs. Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally. PMID:25898845

  19. Considerations Related To Human Intrusion In The Context Of Disposal Of Radioactive Waste-The IAEA HIDRA Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seitz, Roger; Kumano, Yumiko; Bailey, Lucy

    2014-01-09

    The principal approaches for management of radioactive waste are commonly termed ‘delay and decay’, ‘concentrate and contain’ and ‘dilute and disperse’. Containing the waste and isolating it from the human environment, by burying it, is considered to increase safety and is generally accepted as the preferred approach for managing radioactive waste. However, this approach results in concentrated sources of radioactive waste contained in one location, which can pose hazards should the facility be disrupted by human action in the future. The International Commission on Radiological Protection (ICRP), International Atomic Energy Agency (IAEA), and Organization for Economic Cooperation and Development/Nuclear Energymore » Agency (OECD/NEA) agree that some form of inadvertent human intrusion (HI) needs to be considered to address the potential consequences in the case of loss of institutional control and loss of memory of the disposal facility. Requirements are reflected in national regulations governing radioactive waste disposal. However, in practice, these requirements are often different from country to country, which is then reflected in the actual implementation of HI as part of a safety case. The IAEA project on HI in the context of Disposal of RadioActive waste (HIDRA) has been started to identify potential areas for improved consistency in consideration of HI. The expected outcome is to provide recommendations on how to address human actions in the safety case in the future, and how the safety case may be used to demonstrate robustness and optimize siting, design and waste acceptance criteria within the context of a safety case.« less

  20. Energy-Aware RFID Anti-Collision Protocol.

    PubMed

    Arjona, Laura; Simon, Hugo Landaluce; Ruiz, Asier Perallos

    2018-06-11

    The growing interest in mobile devices is transforming wireless identification technologies. Mobile and battery-powered Radio Frequency Identification (RFID) readers, such as hand readers and smart phones, are are becoming increasingly attractive. These RFID readers require energy-efficient anti-collision protocols to minimize the tag collisions and to expand the reader's battery life. Furthermore, there is an increasing interest in RFID sensor networks with a growing number of RFID sensor tags. Thus, RFID application developers must be mindful of tag anti-collision protocols. Energy-efficient protocols involve a low reader energy consumption per tag. This work presents a thorough study of the reader energy consumption per tag and analyzes the main factor that affects this metric: the frame size update strategy. Using the conclusion of this analysis, the anti-collision protocol Energy-Aware Slotted Aloha (EASA) is presented to decrease the energy consumption per tag. The frame size update strategy of EASA is configured to minimize the energy consumption per tag. As a result, EASA presents an energy-aware frame. The performance of the proposed protocol is evaluated and compared with several state of the art Aloha-based anti-collision protocols based on the current RFID standard. Simulation results show that EASA, with an average of 15 mJ consumed per tag identified, achieves a 6% average improvement in the energy consumption per tag in relation to the strategies of the comparison.