Hasselberg, Michael J; McMahon, James; Parker, Kathy
2013-01-01
Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.
Ways to measure body temperature in the field.
Langer, Franz; Fietz, Joanna
2014-05-01
Body temperature (Tb) represents one of the key parameters in ecophysiological studies with focus on energy saving strategies. In this study we therefore comparatively evaluated the usefulness of two types of temperature-sensitive passive transponders (LifeChips and IPTT-300) and one data logger (iButton, DS1922L) mounted onto a collar to measure Tb in the field. First we tested the accuracy of all three devices in a water bath with water temperature ranging from 0 to 40°C. Second, we evaluated the usefulness of the LifeChips and the modified iButtons for measuring Tb of small heterothermic mammals under field conditions. For this work we subcutaneously implanted 14 male edible dormice (Glis glis) with transponders, and equipped another 14 males with data loggers to simultaneously record Tb and oxygen consumption with a portable oxygen analyzer (Oxbox). In one individual we recorded Tb with both devices and analyzed recorded Tb patterns. LifeChips are able to measure temperature within the smallest range from 25 to 40°C with an accuracy of 0.07±0.12°C. IPTT-300 transponders measured temperature between 10 and 40°C, but accuracy decreased considerably at values below 30°C, with maximal deviations of nearly 7°C. An individual calibration of each transponder is therefore needed, before using it at low Tbs. The accuracy of the data logger was comparatively good (0.12±0.25°C) and stable over the whole temperature range tested (0-40°C). In all three devices, the repeatability of measurements was high. LifeChip transponders as well as modified iButtons measured Tb reliably under field conditions. Simultaneous Tb-recordings in one edible dormouse with an implanted LifeChip and a collar-mounted iButton revealed that values of both measurements were closely correlated. Taken together, we conclude that implanted temperature-sensitive transponders represent an appropriate and largely non-invasive method to measure Tb also under field conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Further miniaturisation of the Thermochron iButton to create a thermal bio-logger weighing 0.3 g.
Virens, Josef; Cree, Alison
2018-06-05
Thermochron iButtons are commonly used by thermal biologists to continuously measure body temperature from animals. However, if unmodified, these devices are of a size that limits their use with very small animals. To allow iButtons to be used to study smaller species, methods to miniaturise them by 61% have been previously described. We present a method to reduce iButton mass by a further 71%. The modified devices have a shorter battery life, but the minimum size of vertebrates able to carry the devices is reduced from 28.9 g to 6.6 g, if the arbitrary, yet widely cited, maximum of 5% body mass for attached devices is adhered to. We demonstrate the application of our method by recording surface temperatures of captive and wild skinks and show that captive cockroaches weighing 0.8 g are also able to carry the device. We believe this to be the first time that temperature data have been recorded from an insect in this way. © 2018. Published by The Company of Biologists Ltd.
Monitoring the Temperature of Tree Seedlings With the Thermochron iButton Data Logger
David S. Gasvoda; Richard W. Tinus; Karen E. Burr; Andy Trent
2002-01-01
Tracking the temperature of tree seedlings from the nursery to the planting site can be the key to evaluating possible physiological causes of morality after seedlings are planted. Seedlings enter and leave nursery storage with easily documented levels of cold hardiness, root growth potential, and general stress tolerance (Burr 1990: Ritchie and Tanaka 1990). The...
Brabyn, Lars; Zawar-Reza, Peyman; Stichbury, Glen; Cary, Craig; Storey, Bryan; Laughlin, Daniel C; Katurji, Marwan
2014-04-01
The McMurdo Dry Valleys of Antarctica are the largest snow/ice-free regions on this vast continent, comprising 1% of the land mass. Due to harsh environmental conditions, the valleys are bereft of any vegetation. Land surface temperature is a key determinate of microclimate and a driver for sensible and latent heat fluxes of the surface. The Dry Valleys have been the focus of ecological studies as they arguably provide the simplest trophic structure suitable for modelling. In this paper, we employ a validation method for land surface temperatures obtained from Landsat 7 ETM + imagery and compared with in situ land surface temperature data collected from four transects totalling 45 iButtons. A single meteorological station was used to obtain a better understanding of daily and seasonal cycles in land surface temperatures. Results show a good agreement between the iButton and the Landsat 7 ETM + product for clear sky cases. We conclude that Landsat 7 ETM + derived land surface temperatures can be used at broad spatial scales for ecological and meteorological research.
Adam, D; Johnston, S D; Beard, L; Nicholson, V; Lisle, A; Gaughan, J; Larkin, R; Theilemann, P; Mckinnon, A; Ellis, W
2016-01-01
Under predicted climate change scenarios, koala distribution in Australia is expected to be adversely affected. Recent studies have attempted to identify suitable habitat, based on models of bioclimatic regions, but to more accurately reflect the thermal tolerance and behavioural adaptations of the various regional populations, the koala's response to periods of heat stress will need to be investigated at the individual animal level. To explore the safety and suitability of temperature-sensitive intra-abdominal implants for monitoring core body temperature in the koala. A temperature-sensitive radio transmitter and thermal iButton data-logger, waxed together as a package, were surgically implanted into the abdominal cavity of four captive koalas. In one animal the implant was tethered and in the other three, it was left free-floating. After 3 months, the implants were removed and all four koalas recovered without complications. The tethering of the package in the one koala resulted in minor inflammation and adhesion, so this practice was subsequently abandoned. The free-floating deployments were complication-free and revealed a diurnal body temperature rhythm, with daily ranges of 0.4-2.8°C. The minimum recorded body temperature was 34.2°C and the maximum was 37.7°C. The difference in the readings obtained from the transmitters and iButtons never exceeded 0.3°C. The suitability of the surgical approach was confirmed, from both the animal welfare and data collection points of view. © 2016 Australian Veterinary Association.
Pascual-Alonso, M; Miranda-de la Lama, G C; Aguayo-Ulloa, L; Villarroel, M; Mitchell, M; María, G A
2017-06-01
The study was conducted to evaluate the thermophysiological, haematological, biochemical and behavioural stress responses of sheep transported on road. A total of 44 Chamarita breed adult ewes were randomly allotted to one of two groups, one control group (untransported) and transported group (journey of 4 h), and blood stress indicators were measured 1 day before transport and at four time points post-transport (0, 4 and 24 h). Thermophysiological profiles of ewes were measured by temperature buttons (iButton Thermochron ® ) and placed in intravaginal sponges. Direct observations, with a combination of scan and behaviour sampling, were carried out to collect information on individual behaviour and the time it took the ewes to drink water, eat and rest after returning to their pen respectively. Transported ewes lost approximately 1 kg live weight compared to controls and had higher body temperatures until 12 h post-transport. Cortisol, glucose, non-esterified fatty acid (NEFA) concentrations as well as the neutrophil-lymphocyte ratio (N/L) and other physiological indicators were higher immediately after unloading in transported ewes but mostly returned to normal after 4 h, with complete recovery after 24 h. Behavioural analysis post-transport demonstrated that transported ewes chose to eat before drinking and spent less time resting than controls in the first 3 h after unloading. The study demonstrates that transportation even under short-journey conditions induced behavioural, physiological and thermophysiological responses indicative of the induction of significant stress, leading to live weight shrinkage that may jeopardize farmer's incomes. Finally, results of this study validated the use of iButton Thermochron ® data loggers for monitoring the stress response during transport. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.
Thermocron iButton and iBBat temperature dataloggers emit ultrasound.
Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H
2009-10-01
Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.
Martinez-Tellez, Borja; Sanchez-Delgado, Guillermo; Acosta, Francisco M; Alcantara, Juan M A; Boon, Mariëtte R; Rensen, Patrick C N; Ruiz, Jonatan R
2017-09-05
Cold exposure is necessary to activate human brown adipose tissue (BAT), resulting in heat production. Skin temperature is an indirect measure to monitor the body's reaction to cold. The aim of this research was to study whether the most used equations to estimate parameters of skin temperature in BAT-human studies measure the same values of temperature in young lean men (n = 11: 23.4 ± 0.5 years, fat mass: 19.9 ± 1.2%). Skin temperature was measured with 26 ibuttons at 1-minute intervals in warm and cold room conditions. We used 12 equations to estimate parameters of mean, proximal, and distal skin temperature as well as skin temperature gradients. Data were analysed with Temperatus software. Significant differences were found across equations to measure the same parameters of skin temperature in warm and cold room conditions, hampering comparison across studies. Based on these findings, we suggest to use a set of 14 ibuttons at anatomical positions reported by ISO STANDARD 9886:2004 plus five ibuttons placed on the right supraclavicular fossa, right middle clavicular bone, right middle upper forearm, right top of forefinger, and right upper chest.
Jang, Tae-Won; Kim, Hyunjoo; Kang, Suk-Hoon; Choo, Sang-Hyo; Lee, In-Seok; Choi, Kyung-Hwa
2017-09-24
Background : Human body temperature varies with circadian rhythm. To determine the effect of shift work on the circadian rhythm of the distal-skin temperature, wrist temperatures were measured. Methods : Wrist-skin temperatures were measured by an iButton ® Temperature Logger. It was measured every 3 min for two and eight consecutive working days in the day and shift workers, respectively. Mesor, amplitude, and acrophase were measured by Cosinor analysis. Results : The shift-worker amplitude dropped significantly as the night shift progressed (0.92 to 0.85 °C), dropped further during rest (0.69 °C), and rose during the morning-shift days (0.82 °C). Day workers still had higher amplitudes (0.93 °C) than the morning-shift workers. The acrophase was delayed during the four night-shift days, then advanced during rest days and the morning-shift days. Nevertheless, the morning-shift worker acrophase was still significantly delayed compared to the day workers (08:03 a.m. vs. 04:11 a.m.). Conclusions : The further reduction of wrist-temperature amplitude during rest after the night shift may be due to the signal circadian rhythm disruption. Reduced amplitudes have been reported to be associated with intolerance to shift work. The findings of our study may help to design the most desirable schedule for shift workers.
Ghirlando, Rodolfo; Balbo, Andrea; Piszczek, Grzegorz; Brown, Patrick H; Lewis, Marc S; Brautigam, Chad A; Schuck, Peter; Zhao, Huaying
2013-09-01
Sedimentation velocity (SV) is a method based on first principles that provides a precise hydrodynamic characterization of macromolecules in solution. Due to recent improvements in data analysis, the accuracy of experimental SV data emerges as a limiting factor in its interpretation. Our goal was to unravel the sources of experimental error and develop improved calibration procedures. We implemented the use of a Thermochron iButton temperature logger to directly measure the temperature of a spinning rotor and detected deviations that can translate into an error of as much as 10% in the sedimentation coefficient. We further designed a precision mask with equidistant markers to correct for instrumental errors in the radial calibration that were observed to span a range of 8.6%. The need for an independent time calibration emerged with use of the current data acquisition software (Zhao et al., Anal. Biochem., 437 (2013) 104-108), and we now show that smaller but significant time errors of up to 2% also occur with earlier versions. After application of these calibration corrections, the sedimentation coefficients obtained from 11 instruments displayed a significantly reduced standard deviation of approximately 0.7%. This study demonstrates the need for external calibration procedures and regular control experiments with a sedimentation coefficient standard. Published by Elsevier Inc.
A simple method to predict body temperature of small reptiles from environmental temperature.
Vickers, Mathew; Schwarzkopf, Lin
2016-05-01
To study behavioral thermoregulation, it is useful to use thermal sensors and physical models to collect environmental temperatures that are used to predict organism body temperature. Many techniques involve expensive or numerous types of sensors (cast copper models, or temperature, humidity, radiation, and wind speed sensors) to collect the microhabitat data necessary to predict body temperatures. Expense and diversity of requisite sensors can limit sampling resolution and accessibility of these methods. We compare body temperature predictions of small lizards from iButtons, DS18B20 sensors, and simple copper models, in both laboratory and natural conditions. Our aim was to develop an inexpensive yet accurate method for body temperature prediction. Either method was applicable given appropriate parameterization of the heat transfer equation used. The simplest and cheapest method was DS18B20 sensors attached to a small recording computer. There was little if any deficit in precision or accuracy compared to other published methods. We show how the heat transfer equation can be parameterized, and it can also be used to predict body temperature from historically collected data, allowing strong comparisons between current and previous environmental temperatures using the most modern techniques. Our simple method uses very cheap sensors and loggers to extensively sample habitat temperature, improving our understanding of microhabitat structure and thermal variability with respect to small ectotherms. While our method was quite precise, we feel any potential loss in accuracy is offset by the increase in sample resolution, important as it is increasingly apparent that, particularly for small ectotherms, habitat thermal heterogeneity is the strongest influence on transient body temperature.
NASA Astrophysics Data System (ADS)
Zuvela-Aloise, Maja; Weyss, Gernot; Aloise, Giulliano; Mifka, Boris; Löffelmann, Philemon; Hollosi, Brigitta; Nemec, Johana; Vucetic, Visnja
2014-05-01
In the recent years there has been a strong interest in exploring the potential of low-cost measurement devices as alternative source of meteorological monitoring data, especially in the urban areas where high-density observations become crucial for appropriate heat load assessment. One of the simple, but efficient approaches for gathering large amount of spatial data is through mobile measurement campaigns in which the sensors are attached to driving vehicles. However, non-standardized data collecting procedure, instrument quality, their response-time and design, variable device ventilation and radiation protection influence the reliability of the gathered data. We investigate what accuracy can be expected from the data collected through low-cost mobile measurements and whether the achieved quality of the data is sufficient for validation of the state-of-the-art local-scale climate models. We tested 5 types of temperature sensors and data loggers: Maxim iButton, Lascar EL-USB-2-LCD+ and Onset HOBO UX100-003 as market available devices and self-designed solar powered Arduino-based data loggers combined with the AOSONG AM2315 and Sensirion SHT21 temperature and humidity sensors. The devices were calibrated and tested in stationary mode at the Austrian Weather Service showing accuracy between 0.1°C and 0.8°C, which was mostly within the device specification range. In mobile mode, the best response-time was found for self-designed device with Arduino-based data logger and Sensirion SHT21 sensor. However, the device lacks the mechanical robustness and should be further improved for broad-range applications. We organized 4 measurement tours: two taking place in urban environment (Vienna, Austria in July 2011 and July 2013) and two in countryside with complex terrain of Mid-Adriatic islands (Hvar and Korcula, Croatia in August 2013). Measurements were taken on clear-sky, dry and hot days. We combined multiple devices attached to bicycle and cars with different radiation protection. Duration of each measurement tour lasted approximately 2 hours covering the distances in radius of about 10-30 km, logging the air temperature and geographical positioning in intervals of 1-5 seconds. The collected data were aggregated on a 100 m horizontal resolution grid and compared with the local-scale climate modelling simulations with the urban climate model MUKLIMO3 initialized with the atmospheric conditions for a given day. Both measurement and modelling results show similar features for distinct local climate zones (built-up area, near water environment, forest, parks, agricultural area, etc). The spatial gradients in temperature can be assigned to different orographical and land use characteristics. Even if many ambiguities remain in both modelling and the measurement approach, the collected data provide useful information for local-scale heat assessment and can serve as a base to increase the model reliability, especially in areas with low data coverage.
Ad hoc instrumentation methods in ecological studies produce highly biased temperature measurements
Terando, Adam J.; Youngsteadt, Elsa; Meineke, Emily K.; Prado, Sara G.
2017-01-01
In light of global climate change, ecological studies increasingly address effects of temperature on organisms and ecosystems. To measure air temperature at biologically relevant scales in the field, ecologists often use small, portable temperature sensors. Sensors must be shielded from solar radiation to provide accurate temperature measurements, but our review of 18 years of ecological literature indicates that shielding practices vary across studies (when reported at all), and that ecologists often invent and construct ad hoc radiation shields without testing their efficacy. We performed two field experiments to examine the accuracy of temperature observations from three commonly used portable data loggers (HOBO Pro, HOBO Pendant, and iButton hygrochron) housed in manufactured Gill shields or ad hoc, custom‐fabricated shields constructed from everyday materials such as plastic cups. We installed this sensor array (five replicates of 11 sensor‐shield combinations) at weather stations located in open and forested sites. HOBO Pro sensors with Gill shields were the most accurate devices, with a mean absolute error of 0.2°C relative to weather stations at each site. Error in ad hoc shield treatments ranged from 0.8 to 3.0°C, with the largest errors at the open site. We then deployed one replicate of each sensor‐shield combination at five sites that varied in the amount of urban impervious surface cover, which presents a further shielding challenge. Bias in sensors paired with ad hoc shields increased by up to 0.7°C for every 10% increase in impervious surface. Our results indicate that, due to variable shielding practices, the ecological literature likely includes highly biased temperature data that cannot be compared directly across studies. If left unaddressed, these errors will hinder efforts to predict biological responses to climate change. We call for greater standardization in how temperature data are recorded in the field, handled in analyses, and reported in publications.
Optimising crime scene temperature collection for forensic entomology casework.
Hofer, Ines M J; Hart, Andrew J; Martín-Vega, Daniel; Hall, Martin J R
2017-01-01
The value of minimum post-mortem interval (minPMI) estimations in suspicious death investigations from insect evidence using temperature modelling is indisputable. In order to investigate the reliability of the collected temperature data used for modelling minPMI, it is necessary to study the effects of data logger location on the accuracy and precision of measurements. Digital data logging devices are the most commonly used temperature measuring devices in forensic entomology, however, the relationship between ambient temperatures (measured by loggers) and body temperatures has been little studied. The placement of loggers in this study in three locations (two outdoors, one indoors) had measurable effects when compared with actual body temperature measurements (simulated with pig heads), some more significant than others depending on season, exposure to the environment and logger location. Overall, the study demonstrated the complexity of the question of optimal logger placement at a crime scene and the potential impact of inaccurate temperature data on minPMI estimations, showing the importance of further research in this area and development of a standard protocol. Initial recommendations are provided for data logger placement (within a Stevenson Screen where practical), situations to avoid (e.g. placement of logger in front of windows when measuring indoor temperatures), and a baseline for further research into producing standard guidelines for logger placement, to increase the accuracy of minPMI estimations and, thereby, the reliability of forensic entomology evidence in court. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Spatial-temporal analysis of building surface temperatures in Hung Hom
NASA Astrophysics Data System (ADS)
Zeng, Ying; Shen, Yueqian
2015-12-01
This thesis presents a study on spatial-temporal analysis of building surface temperatures in Hung Hom. Observations were collected from Aug 2013 to Oct 2013 at a 30-min interval, using iButton sensors (N=20) covering twelve locations in Hung Hom. And thermal images were captured in PolyU from 05 Aug 2013 to 06 Aug 2013. A linear regression model of iButton and thermal records is established to calibrate temperature data. A 3D modeling system is developed based on Visual Studio 2010 development platform, using ArcEngine10.0 component, Microsoft Access 2010 database and C# programming language. The system realizes processing data, spatial analysis, compound query and 3D face temperature rendering and so on. After statistical analyses, building face azimuths are found to have a statistically significant relationship with sun azimuths at peak time. And seasonal building temperature changing also corresponds to the sun angle and sun azimuth variations. Building materials are found to have a significant effect on building surface temperatures. Buildings with lower albedo materials tend to have higher temperatures and larger thermal conductivity material have significant diurnal variations. For the geographical locations, the peripheral faces of campus have higher temperatures than the inner faces during day time and buildings located at the southeast are cooler than the western. Furthermore, human activity is found to have a strong relationship with building surface temperatures through weekday and weekend comparison.
Zornoza-Moreno, Matilde; Fuentes-Hernández, Silvia; Sánchez-Solis, Manuel; Rol, María Ángeles; Larqué, Elvira; Madrid, Juan Antonio
2011-05-01
The authors developed a method useful for home measurement of temperature, activity, and sleep rhythms in infants under normal-living conditions during their first 6 mos of life. In addition, parametric and nonparametric tests for assessing circadian system maturation in these infants were compared. Anthropometric parameters plus ankle skin temperature and activity were evaluated in 10 infants by means of two data loggers, Termochron iButton (DS1291H, Maxim Integrated Products, Sunnyvale, CA) for temperature and HOBO Pendant G (Hobo Pendant G Acceleration, UA-004-64, Onset Computer Corporation, Bourne, MA) for motor activity, located in special baby socks specifically designed for the study. Skin temperature and motor activity were recorded over 3 consecutive days at 15 days, 1, 3, and 6 mos of age. Circadian rhythms of skin temperature and motor activity appeared at 3 mos in most babies. Mean skin temperature decreased significantly by 3 mos of life relative to previous measurements (p = .0001), whereas mean activity continued to increase during the first 6 mos. For most of the parameters analyzed, statistically significant changes occurred at 3-6 mos relative to 0.5-1 mo of age. Major differences were found using nonparametric tests. Intradaily variability in motor activity decreased significantly at 6 mos of age relative to previous measurements, and followed a similar trend for temperature; interdaily stability increased significantly at 6 mos of age relative to previous measurements for both variables; relative amplitude increased significantly at 6 mos for temperature and at 3 mos for activity, both with respect to previous measurements. A high degree of correlation was found between chronobiological parametric and nonparametric tests for mean and mesor and also for relative amplitude versus the cosinor-derived amplitude. However, the correlation between parametric and nonparametric equivalent indices (acrophase and midpoint of M5, interdaily stability and Rayleigh test, or intradaily variability and P(1)/P(ultradian)) despite being significant, was lower for both temperature and activity. The circadian function index (CFI index), based on the integrated variable temperature-activity, increased gradually with age and was statistically significant at 6 mos of age. At 6 mos, 90% of the infants' rest period coincided with the standard sleep period of their parents, defined from 23:00 to 07:00 h (dichotomic index I < O; when I < O = 100%, there is a complete coincidence between infant nocturnal rest period and the standard rest period), whereas at 15 days of life the coincidence was only 75%. The combination of thermometry and actimetry using data loggers placed in infants' socks is a reliable method for assessing both variables and also sleep rhythms in infants under ambulatory conditions, with minimal disturbance. Using this methodological approach, circadian rhythms of skin temperature and motor activity appeared by 3 mos in most babies. Nonparametric tests provided more reliable information than cosinor analysis for circadian rhythm assessment in infants.
Andrew D. George; Frank R. Thompson; John. Faaborg
2015-01-01
A spatial mismatch exists between regional climate models and conditions experienced by individual organisms. We demonstrate an approach to downscaling air temperatures for site-level studies using airborne LiDAR data and remote microclimate loggers. In 2012-2013, we established a temperature logger network in the forested region of central Missouri, USA, and obtained...
Use of Thermochrons in the Classroom
ERIC Educational Resources Information Center
Avard, Margaret Marie
2010-01-01
Preservice elementary education students often do not have a good feel for the process of science. Many may be acquainted with the steps of the scientific method but have never been through the scientific process. An exercise was designed using temperature-logging iButtons (Thermochrons) to improve knowledge of and familiarity with the process of…
Measuring stream temperature with digital data loggers: a user's guide
Jason Dunham; Gwynne Chandler; Bruce Rieman; Don Martin
2005-01-01
Digital data loggers (thermographs) are among the most widespread instruments in use for monitoring physical conditions in aquatic ecosystems. The intent of this protocol is to provide guidelines for selecting and programming data loggers, sampling water temperatures in the field, data screening and analysis, and data archiving.
Goldhawk, C; Crowe, T; González, L A; Janzen, E; Kastelic, J; Pajor, E; Schwartzkopf-Genswein, K
2014-09-01
Measuring animal-level conditions during transit provides information regarding the true risk of environmental challenges to cattle welfare during transportation. However, due to constraints on placing loggers at the animal level, there is a need to identify appropriate proxy locations. The objective was to evaluate 8 distributions of ceiling-level loggers in the deck and belly compartments of pot-belly trailers for assessing animal-level temperature and humidity during 5 to 18 h commercial transportation of feeder cattle. Ambient conditions during transportation ranged from 3.6 to 45.2°C (20.3 ± 7.61°C, mean ± SD). When considering the entire journey, average differences between ceiling and animal-level temperatures were similar among logger layouts (P > 0.05). The uncertainty in the difference in temperature and humidity between locations was high relative to the magnitude of the difference between animal- and ceiling-level conditions. Single-logger layouts required larger adjustments to predict animal-level conditions within either compartment, during either the entire journey or when the trailer was stationary (P < 0.05). Within certain logger layouts, there were small but significant differences in the ability of regression equations to predict animal-level conditions that were associated with cattle weight and available space relative to body size. Furthermore, evaluation of logger layouts based solely on the entire journey without consideration of stationary periods did not adequately capture variability in layout performance. In conclusion, to adequately monitor animal-level temperature and humidity, 10 loggers distributed throughout the compartment was recommended over single-logger layouts within both the deck and belly compartments of pot-belly trailers transporting feeder cattle in warm weather.
Application of vaginal temperature measurement in bitches.
Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W
2012-12-01
Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.
Supraclavicular skin temperature as a measure of 18F-FDG uptake by BAT in human subjects.
Boon, Mariëtte R; Bakker, Leontine E H; van der Linden, Rianne A D; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J; van Marken Lichtenbelt, Wouter D; Jazet, Ingrid M; Rensen, Patrick C N
2014-01-01
Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current 'gold standard' for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. NTR 2473.
Monitoring stream temperatures—A guide for non-specialists
Heck, Michael P.; Schultz, Luke D.; Hockman-Wert, David; Dinger, Eric C.; Dunham, Jason B.
2018-04-19
Executive SummaryWater temperature influences most physical and biological processes in streams, and along with streamflows is a major driver of ecosystem processes. Collecting data to measure water temperature is therefore imperative, and relatively straightforward. Several protocols exist for collecting stream temperature data, but these are frequently directed towards specialists. This document was developed to address the need for a protocol intended for non-specialists (non-aquatic) staff. It provides specific step-by-step procedures on (1) how to launch data loggers, (2) check the factory calibration of data loggers prior to field use, (3) how to install data loggers in streams for year-round monitoring, (4) how to download and retrieve data loggers from the field, and (5) how to input project data into organizational databases.
Niphargus: a silicon band-gap sensor temperature logger for high-precision environmental monitoring
NASA Astrophysics Data System (ADS)
Burlet, Christian; Vanbrabant, Yves; Piessens, Kris; Welkenhuysen, Kris; Verheyden, Sophie
2014-05-01
A temperature logger, called 'Niphargus', was developed at the Geological Survey of Belgium to monitor temperature of local natural processes with sensitivity of the order of a few hundredths of degrees to monitor temperature variability in open air, caves, soils and rivers. The newly developed instrument uses a state-of-the-art band-gap silicon temperature sensor with digital output. This sensor reduces the risk of drift associated with thermistor-based sensing devices, especially in humid environments. The Niphargus is designed to be highly reliable, low-cost and powered by a single lithium cell with up to several years autonomy depending on the sampling rate and environmental conditions. The Niphargus was evaluated in an ice point bath experiment in terms of temperature accuracy and thermal inertia. The small size and low power consumption of the logger allow its use in difficult accessible environments, e.g. caves and space-constrained applications, inside a rock in a water stream. In both cases, the loggers have proven to be reliable and accurate devices. For example, spectral analysis of the temperature signal in the Han caves (Belgium) allowed detection and isolation of a 0.005° C amplitude day-night periodic signal in the temperature curve. PIC Figure 1: a Niphargus logger in its standard size. SMD components side. Photo credit: W. Miseur
Kartoğlu, Umit; Nelaj, Erida; Maire, Denis
2010-05-28
This intervention study was conducted in Albania to establish the superiority of the Fridge-tag (30-day electronic refrigerator temperature logger) against thermometers. Intervention sites used Fridge-tag and a modified temperature control record sheet, while control sites continued with their routine operation with thermometers. All refrigerators in both groups were equipped with downloadable electronic data loggers to record temperatures for reference. Focus group sessions were conducted with involved staff to discuss temperature monitoring, Fridge-tag use and its user-friendliness. Significant discrepancies were observed between thermometer readings and the electronic data loggers in control sites, while all alarms from Fridge-tag were confirmed in the intervention group. Thermometers are not sufficient to monitor temperatures in refrigerators since they miss the great majority of low and high alarms. Fridge-tag has proven to be an effective tool in providing health workers with the information they need to take the necessary actions when there are refrigerator temperature variations. (c) 2010 Elsevier Ltd. All rights reserved.
Carnley, Mark V.
2015-01-01
The Pressure Water Level Data Logger manufactured by Infinities USA, Inc., was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility for conformance with the manufacturer’s stated accuracy specifications for measuring pressure throughout the device’s operating temperature range and with the USGS accuracy requirements for water-level measurements. The Pressure Water Level Data Logger (Infinities Logger) is a submersible, sealed, water-level sensing device with an operating pressure range of 0 to 11.5 feet of water over a temperature range of −18 to 49 degrees Celsius. For the pressure range tested, the manufacturer’s accuracy specification of 0.1 percent of full scale pressure equals an accuracy of ±0.138 inch of water. Three Infinities Loggers were evaluated, and the testing procedures followed and results obtained are described in this report. On the basis of the test results, the device is poorly compensated for temperature. For the three Infinities Loggers, the mean pressure differences varied from –4.04 to 5.32 inches of water and were not within the manufacturer’s accuracy specification for pressure measurements made within the temperature-compensated range. The device did not meet the manufacturer’s stated accuracy specifications for pressure within its temperature-compensated operating range of –18 to 49 degrees Celsius or the USGS accuracy requirements of no more than 0.12 inch of water (0.01 foot of water) or 0.10 percent of reading, whichever is larger. The USGS accuracy requirements are routinely examined and reported when instruments are evaluated at the Hydrologic Instrumentation Facility. The estimated combined measurement uncertainty for the pressure cycling test was ±0.139 inch of water, and for temperature, the cycling test was ±0.127 inch of water for the three Infinities Loggers.
NASA Astrophysics Data System (ADS)
Price, J.; Liff, H.; Lakshmi, V.
2012-12-01
Temperature is considered to be one of the most important physical factors in determining organismal distribution and physiological performance of species in rocky intertidal ecosystems, especially the growth and survival of mussels. However, little is known about the spatial and temporal patterns of temperature in intertidal ecosystems or how those patterns affect intertidal mussel species because of limitations in data collection. We collected in situ temperature at Strawberry Hill, Oregon USA using mussel loggers embedded among the intertidal mussel species, Mytilus californianus. Remotely sensed surface temperatures were used in conjunction with in situ weather and ocean data to determine if remotely sensed surface temperatures can be used as a predictor for changes in the body temperature of a rocky intertidal mussel species. The data used in this study was collected between January 2003 and December 2010. The mussel logger temperatures were compared to in situ weather data collected from a local weather station, ocean data collected from a NOAA buoy, and remotely sensed surface temperatures collected from NASA's sun-synchronous Moderate Resolution Imaging Spectroradiometer aboard the Earth Observing System Aqua and EOS Terra satellites. Daily surface temperatures were collected from four pixel locations which included two sea surface temperature (SST) locations and two land surface temperature (LST) locations. One of the land pixels was chosen to represent the intertidal surface temperature (IST) because it was located within the intertidal zone. As expected, all surface temperatures collected via satellite were significantly correlated to each other and the associated in situ temperatures. Examination of temperatures from the off-shore NOAA buoy and the weather station provide evidence that remotely sensed temperatures were similar to in situ temperature data and explain more variability in mussel logger temperatures than the in situ temperatures. Our results suggest that temperatures (surface temperature and air temperature) are similar across larger spatial scales even when the type of data collection is different. Mussel logger temperatures were strongly correlated to SSTs and were not significantly different than SSTs. Sea surface temperature collected during the Aqua overpass explained 67.1% of the variation in mean monthly mussel logger temperature. When SST, LST, and IST were taken into consideration, nearly 73% of the variation in mussel logger temperature was explained. While in situ monthly air temperature and water temperature explained only 28-33% of the variation in mussel logger temperature. Our results suggests that remotely sensed surface temperatures are reliable and important measurements that can be used to better understand the effects temperature may have on intertidal mussel species in Strawberry Hill, Oregon. Remotely sensed surface temperature could act as a relative indicator of change and may be used to predict general habitat trends and drivers that could directly affect organism body temperature.
da Cunha, Antonio Ribeiro
2015-05-01
This study aimed to assess measurements of temperature and relative humidity obtained with HOBO a data logger, under various conditions of exposure to solar radiation, comparing them with those obtained through the use of a temperature/relative humidity probe and a copper-constantan thermocouple psychrometer, which are considered the standards for obtaining such measurements. Data were collected over a 6-day period (from 25 March to 1 April, 2010), during which the equipment was monitored continuously and simultaneously. We employed the following combinations of equipment and conditions: a HOBO data logger in full sunlight; a HOBO data logger shielded within a white plastic cup with windows for air circulation; a HOBO data logger shielded within a gill-type shelter (multi-plate prototype plastic); a copper-constantan thermocouple psychrometer exposed to natural ventilation and protected from sunlight; and a temperature/relative humidity probe under a commercial, multi-plate radiation shield. Comparisons between the measurements obtained with the various devices were made on the basis of statistical indicators: linear regression, with coefficient of determination; index of agreement; maximum absolute error; and mean absolute error. The prototype multi-plate shelter (gill-type) used in order to protect the HOBO data logger was found to provide the best protection against the effects of solar radiation on measurements of temperature and relative humidity. The precision and accuracy of a device that measures temperature and relative humidity depend on an efficient shelter that minimizes the interference caused by solar radiation, thereby avoiding erroneous analysis of the data obtained.
NASA Astrophysics Data System (ADS)
Gillman, M. A.; Lamoureux, S. F.; Lafrenière, M. J.
2017-09-01
The Stream Temperature, Intermittency, and Conductivity (STIC) electrical conductivity (EC) logger as presented by Chapin et al. (2014) serves as an inexpensive (˜50 USD) means to assess relative EC in freshwater environments. This communication demonstrates the calibration of the STIC logger for quantifying EC, and provides examples from a month long field deployment in the High Arctic. Calibration models followed multiple nonlinear regression and produced calibration curves with high coefficient of determination values (R2 = 0.995 - 0.998; n = 5). Percent error of mean predicted specific conductance at 25°C (SpC) to known SpC ranged in magnitude from -0.6% to 13% (mean = -1.4%), and mean absolute percent error (MAPE) ranged from 2.1% to 13% (mean = 5.3%). Across all tested loggers we found good accuracy and precision, with both error metrics increasing with increasing SpC values. During 10, month-long field deployments, there were no logger failures and full data recovery was achieved. Point SpC measurements at the location of STIC loggers recorded via a more expensive commercial electrical conductivity logger followed similar trends to STIC SpC records, with 1:1.05 and 1:1.08 relationships between the STIC and commercial logger SpC values. These results demonstrate that STIC loggers calibrated to quantify EC are an economical means to increase the spatiotemporal resolution of water quality investigations.
Mountain Permafrost in the Yukon Territory, Canada: Mapping and Modelling
NASA Astrophysics Data System (ADS)
Lewkowicz, A. G.; Bonnaventure, P.; Schultz, E.; Etzelmuller, B.
2006-12-01
The distribution and characteristics of mountain permafrost in North America are poorly known compared to lowland permafrost, and predictions of climatic change impacts are therefore subject to a higher degree of uncertainty. Recent DC resistivity soundings in association with borehole temperature information in the Yukon Territory, show the wide range of permafrost conditions that can exist at sites separated by short distances. To provide baseline information for future modelling, efforts are underway to produce a detailed map of permafrost probability in the mountains of the southern half of the Yukon Territory (60-65°N), an area greater than 200 x 103km2. The methodology is based on the Basal Temperature of Snow (BTS) technique, first developed in the European Alps. Ground surface temperatures measured at the base of snow > 80 cm thick in late winter are an indicator of permafrost presence or absence. We have used this method successfully in three study areas of about 200 km2: first, Wolf Creek basin near Whitehorse (Lewkowicz and Ednie, 2004) and now the western side of the Ruby Range adjacent to Kluane Lake, and the Haines Summit area in northwestern British Columbia. In each area, (1) we installed miniature temperature loggers at the ground surface and in the air to check on the timing of the BTS measurements; (2) we measured BTS values in the elevation zone across which permafrost was expected to become widespread; (3) we modelled the BTS spatial field using elevation (from a 30 m DEM) and potential incoming solar radiation (PISR) as the independent variables; and (4) we used logistic regression to compare the modelled BTS values with pit observations made in late-summer of the presence or absence of frozen ground. Both elevation and PISR were significant in the Wolf Creek and Ruby Range sites which have relatively continental climates and fall within the Upper Yukon-Stikine Basin climatic region (Wahl et al., 1987). For the Haines Summit area, however, PISR was not significant, likely reflecting the much more maritime climate of this area and the frequent fogs that are present. More than 50 new air and ground temperature monitoring stations were installed in spring 2006 as the first step to extend the modelling to the remaining mountainous parts of the Yukon Territory. We selected sites within the four climatic regions encompassing discontinuous permafrost that we had not previously sampled: the Faro area (Central Yukon Basin region, extensive discontinuous zone), Johnson's Crossing (Pelly-Cassiar Mountains region, sporadic discontinuous zone), Sa Dena Hes mine (Liard Basin region, extensive discontinuous zone) and the Keno area (Ogilvie-Mackenzie Mountains region, extensive discontinuous zone). Each of the stations is equipped to measure air temperature, ground surface temperature, ground temperature at a depth of 1 m (to evaluate the thermal offset), and snow depth (interpreted from I-button miniature loggers installed on a stake). These measurements will not only be used for permafrost modelling but will generate a unique data-set of air and ground surface temperatures which will be employed to investigate the frequency of air temperature inversions, their relation to topography and their effect on permafrost. The first complete monthly results (July 2006) demonstrate the expected wide variability in air and ground surface temperatures at both regional and local scales that makes modelling mountain permafrost so challenging.
Chapin, Thomas; Todd, Andrew S.; Zeigler, Matthew P.
2014-01-01
Water temperature and streamflow intermittency are critical parameters influencing aquatic ecosystem health. Low-cost temperature loggers have made continuous water temperature monitoring relatively simple but determining streamflow timing and intermittency using temperature data alone requires significant and subjective data interpretation. Electrical resistance (ER) sensors have recently been developed to overcome the major limitations of temperature-based methods for the assessment of streamflow intermittency. This technical note introduces the STIC (Stream Temperature, Intermittency, and Conductivity logger); a robust, low-cost, simple to build instrument that provides long-duration, high-resolution monitoring of both relative conductivity (RC) and temperature. Simultaneously collected temperature and RC data provide unambiguous water temperature and streamflow intermittency information that is crucial for monitoring aquatic ecosystem health and assessing regulatory compliance. With proper calibration, the STIC relative conductivity data can be used to monitor specific conductivity.
NASA Astrophysics Data System (ADS)
Anderson, T.; Jencso, K. G.; Hoylman, Z. H.; Hu, J.
2015-12-01
Characterizing the mechanisms that lead to differences in forest ecosystem productivity across complex terrain remains a challenge. This difficulty can be partially attributed to the cost of installing networks of proprietary data loggers that monitor differences in the biophysical factors contributing to tree growth. Here, we describe the development and initial application of a network of open source data loggers. These data loggers are based on the Arduino platform, but were refined into a custom printed circuit board (PCB). This reduced the cost and complexity of the data loggers, which made them cheap to reproduce and reliable enough to withstand the harsh environmental conditions experienced in Ecohydrology studies. We demonstrate the utility of these loggers for high frequency, spatially-distributed measurements of sap-flux, stem growth, relative humidity, temperature, and soil water content across 36 landscape positions in the Lubrecht Experimental Forest, MT, USA. This new data logging technology made it possible to develop a spatially distributed monitoring network within the constraints of our research budget and may provide new insights into factors affecting forest productivity across complex terrain.
Supraclavicular Skin Temperature as a Measure of 18F-FDG Uptake by BAT in Human Subjects
van der Linden, Rianne A. D.; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J.; van Marken Lichtenbelt, Wouter D.
2014-01-01
Background Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current ‘gold standard’ for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. Subjects/Methods BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Results Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Conclusions Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. Trial Registration NTR 2473 PMID:24922545
Bach, Aaron J E; Stewart, Ian B; Disher, Alice E; Costello, Joseph T
2015-01-01
Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Mean skin temperature ([Formula: see text]) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). [Formula: see text] was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Bland-Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of [Formula: see text] found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring [Formula: see text] in the presence of, or following, metabolic and environmental induced heat stress.
NASA Astrophysics Data System (ADS)
2012-07-01
WE RECOMMEND Data logger Fourier NOVA LINK: data logging and analysis To Engineer is Human Engineering: essays and insights Soap, Science, & Flat-Screen TVs People, politics, business and science overlap uLog sensors and sensor adapter A new addition to the LogIT range offers simplicity and ease of use WORTH A LOOK Imagined Worlds Socio-scientific predictions for the future Mini light data logger and mini temperature data logger Small-scale equipment for schools SensorLab Plus LogIT's supporting software, with extra features HANDLE WITH CARE CAXE110P PICAXE-18M2 data logger Data logger 'on view' but disappoints Engineering: A Very Short Introduction A broad-brush treatment fails to satisfy WEB WATCH Two very different websites for students: advanced physics questions answered and a more general BBC science resource
Methods for accurate cold-chain temperature monitoring using digital data-logger thermometers
NASA Astrophysics Data System (ADS)
Chojnacky, M. J.; Miller, W. M.; Strouse, G. F.
2013-09-01
Complete and accurate records of vaccine temperature history are vital to preserving drug potency and patient safety. However, previously published vaccine storage and handling guidelines have failed to indicate a need for continuous temperature monitoring in vaccine storage refrigerators. We evaluated the performance of seven digital data logger models as candidates for continuous temperature monitoring of refrigerated vaccines, based on the following criteria: out-of-box performance and compliance with manufacturer accuracy specifications over the range of use; measurement stability over extended, continuous use; proper setup in a vaccine storage refrigerator so that measurements reflect liquid vaccine temperatures; and practical methods for end-user validation and establishing metrological traceability. Data loggers were tested using ice melting point checks and by comparison to calibrated thermocouples to characterize performance over 0 °C to 10 °C. We also monitored logger performance in a study designed to replicate the range of vaccine storage and environmental conditions encountered at provider offices. Based on the results of this study, the Centers for Disease Control released new guidelines on proper methods for storage, handling, and temperature monitoring of vaccines for participants in its federally-funded Vaccines for Children Program. Improved temperature monitoring practices will ultimately decrease waste from damaged vaccines, improve consumer confidence, and increase effective inoculation rates.
NASA Astrophysics Data System (ADS)
Rao, Amar P.
The Davis-Schrimpf Seep Field is a cluster of about 50 transtension-related geothermal seeps in the Imperial Valley, southeastern California. Five temperature time-series were collected from four features and compared to one another, against prior time-series, and to local seismicity. Loggers placed in separate vents within one seep returned moderate anti-correlation. Vents may selectively clog and unclog. Clogging frequencies explaining the observed level of negative correlation were given. Loggers placed in the same vent produced 87-92% positive correlation. It is therefore likely that the vast majority of temperature data measured with loggers possesses meaningful accuracy. Loggers placed in separate seeps exhibited correlation close to or greater than the statistically significant 60% threshold. I propose two lineaments provide a hydraulic connection between these seeps. Two Mw>3.0 earthquake swarms, including one Mw>4.0 event, within 24 kilometers showed possible linkage with >5 degree Celsius temperature perturbations. Seepage warmed 14.5-36.8 degrees Celsius over 5-7 years.
Full-Scale Accelerated Pavement Testing of Warm-Mix Asphalt (WMA) for Airfield Pavements
2014-01-01
software and Pavement Engineering Utility (PSEVEN) were used 50 ft 65 ft 130 ft 24 ft Item 3 Sasobit ® Item 4 Evotherm 3G Item 1 HMA... Evotherm 3G Air Top Mid-depth Bottom Target temperature = 109 ºF ERDC/GSL TR-14-3 25 The target pavement temperature for this study was 109 ºF, and it is...the locations of the I-buttons and their layout in relation to the vents. 90 95 100 105 110 115 120 HMA Foamed Asphalt Sasobit Evotherm 3G Av er ag e
NASA Astrophysics Data System (ADS)
van de Ven, C.; Weiss, S. B.
2009-12-01
Most climate models are expressed at regional scales, with resolutions on the scales of kilometers. When used for ecological modeling, these climate models help explain only broad-scale trends, such as latitudinal and upslope migration of plants. However, more refined ecological models require down-scaled climate data at ecologically relevant spatial scales, and the goal of this presentation is to demonstrate robust downscaling methods. For example, in the White Mountains, eastern California, tree species, including bristlecone pine (Pinus longaeva) are seen moving not just upslope, but also sideways across aspects, and downslope into areas characterized by cold air drainage. Macroclimate in the White Mountains is semi-arid, residing in the rain shadow of the Sierra Nevada. Macroclimate is modified by mesoscale effects of mountain ranges, where climate becomes wetter and colder with elevation, the temperature decreasing according to the regionally and temporally-specific lapse rate. Local topography further modifies climate, where slope angle, aspect, and topographic position further impact the temperature at a given site. Finally, plants experience extremely localized microclimate, where surrounding vegetation provide differing degrees of shade. We measured and modeled topoclimate across the White Mountains using iButton Thermochron temperature data loggers during late summer in 2006 and 2008, and have documented effects of microclimatic temperature differences between sites in the open and shaded by shrubs. Starting with PRISM 800m data, we derived mesoscale lapse rates. Then, we calculated temperature differentials between each Thermochron and a long-term weather station in the middle of the range at Crooked Creek Valley. We modeled month-specific minimum temperature differentials by regressing the Thermochron-weather station minimum temperature differentials with various topographic parameters. Topographic position, the absolute value of topographic position, and slope combined to provide a very close fit (r2>0.9) to measured inversions of >8°C. Although topoclimatic maximum temperature models have been more elusive, regressions with degree hours greater than zero (DH>0) have been modeled with September insolation and slope (r2=0.7). In paired experiments, Thermochrons also recorded the temperature differences between the environment under sagebrush (Artemisia tridentata) and in the open, with an average minimum temperature difference of 2.1°C, and maximum temperature difference of 4.5°C. When we incorporate hourly weather station data, the strength of the inversion is weakened by wind, higher relative humidity, and cloudiness. This hierarchical modeling provides a template for downscaling climate and weather to ecologically relevant scales.
Development open source microcontroller based temperature data logger
NASA Astrophysics Data System (ADS)
Abdullah, M. H.; Che Ghani, S. A.; Zaulkafilai, Z.; Tajuddin, S. N.
2017-10-01
This article discusses the development stages in designing, prototyping, testing and deploying a portable open source microcontroller based temperature data logger for use in rough industrial environment. The 5V powered prototype of data logger is equipped with open source Arduino microcontroller for integrating multiple thermocouple sensors with their module, secure digital (SD) card storage, liquid crystal display (LCD), real time clock and electronic enclosure made of acrylic. The program for the function of the datalogger is programmed so that 8 readings from the thermocouples can be acquired within 3 s interval and displayed on the LCD simultaneously. The recorded temperature readings at four different points on both hydrodistillation show similar profile pattern and highest yield of extracted oil was achieved on hydrodistillation 2 at 0.004%. From the obtained results, this study achieved the objective of developing an inexpensive, portable and robust eight channels temperature measuring module with capabilities to monitor and store real time data.
McColloster, Patrick; Vallbona, Carlos
2011-01-01
We conducted the first US study using graphic-output temperature data loggers in quantifying cold chain failure. Fifty-four vaccine refrigerators of a county outpatient health system were studied. Forty-eight percent maintained temperatures of 2°C to 8°C and 24% had protracted periods of temperatures less than 0°C. The correlation between the percentage of refrigerators with freezing temperatures and the pertussis rate for each health region was r = 0.76. The findings suggest that improper vaccine storage may have contributed to recent increases in pertussis rates.
A Temperature-Monitoring Vaginal Ring for Measuring Adherence
Boyd, Peter; Desjardins, Delphine; Kumar, Sandeep; Fetherston, Susan M.; Le-Grand, Roger; Dereuddre-Bosquet, Nathalie; Helgadóttir, Berglind; Bjarnason, Ásgeir; Narasimhan, Manjula; Malcolm, R. Karl
2015-01-01
Background Product adherence is a pivotal issue in the development of effective vaginal microbicides to reduce sexual transmission of HIV. To date, the six Phase III studies of vaginal gel products have relied primarily on self-reporting of adherence. Accurate and reliable methods for monitoring user adherence to microbicide-releasing vaginal rings have yet to be established. Methods A silicone elastomer vaginal ring prototype containing an embedded, miniature temperature logger has been developed and tested in vitro and in cynomolgus macaques for its potential to continuously monitor environmental temperature and accurately determine episodes of ring insertion and removal. Results In vitro studies demonstrated that DST nano-T temperature loggers encapsulated in medical grade silicone elastomer were able to accurately and continuously measure environmental temperature. The devices responded quickly to temperature changes despite being embedded in different thickness of silicone elastomer. Prototype vaginal rings measured higher temperatures compared with a subcutaneously implanted device, showed high sensitivity to diurnal fluctuations in vaginal temperature, and accurately detected periods of ring removal when tested in macaques. Conclusions Vaginal rings containing embedded temperature loggers may be useful in the assessment of product adherence in late-stage clinical trials. PMID:25965956
Design of an accurate wireless data logger for vibration analysis with Android interface.
Blanco, J R; Menéndez, J; Ferrero, F J; Campo, J C; Valledor, M
2016-12-01
In this work a new accurate wireless data logger using the Android interface was developed to monitor vibrations at low-cost. The new data logger is completely autonomous and extremely reduced in size. This instrument enables data collection wirelessly and the ability to display it on any tablet or smartphone with operating system Android. The prototype allows the monitoring of any industrial system with minimal investment in material and installation costs. The data logger is capable of making 12.8 kSPS enough to sample up to 5 kHz signals. The basic specification of the data logger includes a high resolution 1-axis piezoelectric accelerometer with a working range of ±30 G. In addition to the acceleration measurements, temperature can also be recorded. The data logger was tested during a 6-month period in industrial environments. The details of the specific hardware and software design are described. The proposed technology can be easily transferred to many other areas of industrial monitoring.
Nelson, Eric D; Huang, Henry
2011-03-01
The utility of temperature/humidity data loggers are evaluated as a low-cost approach to enrich practical understanding of the actual time dependent humidity that a pharmaceutical product is exposed to. While this approach is found to have significant utility in general, small systematic biases in the measurements due to the presence of the data logger are observed. Taking these biases into account enables more productive extrapolation of measured time/humidity profiles. © 2011 American Association of Pharmaceutical Scientists
Bach, Aaron J. E.; Stewart, Ian B.; Disher, Alice E.; Costello, Joseph T.
2015-01-01
Purpose Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Methods Mean skin temperature (T-sk) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). T-sk was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Results Bland–Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of T-sk found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. Conclusions These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring T-sk in the presence of, or following, metabolic and environmental induced heat stress. PMID:25659140
MISSE 1 and 2 Tray Temperature Measurements
NASA Technical Reports Server (NTRS)
Harvey, Gale A.; Kinard, William H.
2006-01-01
The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.
Prediction of parturition in bitches utilizing continuous vaginal temperature measurement.
Geiser, B; Burfeind, O; Heuwieser, W; Arlt, S
2014-02-01
The objective of this study was to determine sensitivity and specificity of a body temperature decline in bitches to predict parturition. Temperature loggers were placed into the vaginal cavity of 16 pregnant bitches on day 56-61 after estimated ovulation or first mating. This measurement technique has been validated previously and enabled continuous sampling of body temperature. The temperature loggers were expelled from the vagina before delivery of the first pup. The computed values for specificity (77-92%) were higher than sensitivity (53-69%), indicating a more precise prognosis of parturition not occurring. In conclusion, our findings may assist interpreting vaginal temperature measurements in order to predict parturition in bitches. © 2013 Blackwell Verlag GmbH.
Ethernet based data logger for gaseous detectors
NASA Astrophysics Data System (ADS)
Swain, S.; Sahu, P. K.; Sahu, S. K.
2018-05-01
A data logger is designed to monitor and record ambient parameters such as temperature, pressure and relative humidity along with gas flow rate as a function of time. These parameters are required for understanding the characteristics of gas-filled detectors such as Gas Electron Multiplier (GEM) and Multi-Wire Proportional Counter (MWPC). The data logger has different microcontrollers and has been interfaced to an ethernet port with a local LCD unit for displaying all measured parameters. In this article, the explanation of the data logger design, hardware, and software description of the master microcontroller and the DAQ system along with LabVIEW interface client program have been presented. We have implemented this device with GEM detector and displayed few preliminary results as a function of above parameters.
VAB Temperature and Humidity Study
NASA Technical Reports Server (NTRS)
Lane, John E.; Youngquist, Robert C.; Muktarian, Edward; Nurge, Mark A.
2014-01-01
In 2012, 17 data loggers were placed in the VAB to measure temperature and humidity at 10-minute intervals over a one-year period. In 2013, the data loggers were replaced with an upgraded model and slight adjustments to their locations were made to reduce direct solar heating effects. The data acquired by the data loggers was compared to temperature data provided by three wind towers located around the building. It was found that the VAB acts as a large thermal filter, delaying and reducing the thermal oscillations occurring outside of the building. This filtering is typically more pronounced at higher locations in the building, probably because these locations have less thermal connection with the outside. We surmise that the lower elevations respond more to outside temperature variations because of air flow through the doors. Temperatures inside the VAB rarely exceed outdoor temperatures, only doing so when measurements are made directly on a surface with connection to the outside (such as a door or wall) or when solar radiation falls directly on the sensor. A thermal model is presented to yield approximate filter response times for various locations in the building. Appendix A contains historical thermal and humidity data from 1994 to 2009.
Calculation of air movement in ice caves by using the CalcFlow method
NASA Astrophysics Data System (ADS)
Meyer, Christiane; Pflitsch, Andreas; Maggi, Valter
2017-04-01
We present a method to determine the air flow regime within ice caves by temperature loggers. Technical capabilities of conducting airflow measurements are restricted by the availability of energy at the ice cave study sites throughout the year. Though the knowledge of the airflow regime is a prerequisite for the understanding of the cave climate. By cross-correlating different time series of air temperature measurements inside a cave, we define the travel time of the air between the loggers, which corresponds to the time shift of best correlation, and use this result to derive the airflow speed. Then we estimate the temperature biases and scale factors for the temperature variations observed by the different loggers by a least squares adjustment. As quality control for bias and scale we use the formal errors of the estimation process. For the calculated airflow speed quality criteria are developed by use of a simulation study. Furthermore we will apply the method to temperature measurements in the static ice cave Schellenberger Eishöhle (Germany). In the end we show how the method can be used as an advanced filter for the separation of different signal contents of the temperature measurements.
Miller, Thomas D; Maxwell, Andrew J; Lindquist, Thomas D; Requard, Jake
2013-01-01
To determine the cooling effect of generic insulated shipping containers in ambient and high-temperature environments. Twenty-seven shipping containers were packed with wet ice according to industry standards. The ice in each container was weighed. Ambient temperatures were recorded by data loggers affixed to the exterior. Internal temperatures were recorded by data loggers packed inside the containers, for as long as the data loggers remained at ≤8°C. The cooling effect, or minutes per gram of ice a data logger maintained a temperature of ≤8°C, was calculated using linear regression; 8 similar containers were subjected to elevated summer temperatures. Small, medium, and large containers held mean masses of wet ice of 685, 1929, and 4439 g, respectively. The linear regression equation for grams of ice to duration of time at ≤8°C was y = 0.1994x + 385.13 for small containers, y = 0.1854x + 1273.3 for medium, and y = 0.5892x + 1410.3 for large containers, resulting in a cooling effect of 25.1 hours for small, 58.9 hours for medium, and 85.7 hours for large containers at ambient temperature. The duration of cooling effect in the summer profile group was consistent with that of the ambient temperature group. All of the container sizes successfully maintained proper cooling when packed with the appropriate grams of wet ice for the needed time interval. This study validates current practice for the shipment of corneal tissue in inexpensive, generic containers that can maintain effective cooling for the duration required for local, national, and international shipment.
Is propensity to obesity associated with the diurnal pattern of core body temperature?
Hynd, P I; Czerwinski, V H; McWhorter, T J
2014-02-01
Obesity affects more than half a billion people worldwide, but the underlying causes remain unresolved. It has been proposed that propensity to obesity may be associated with differences between individuals in metabolic efficiency and in the energy used for homeothermy. It has also been suggested that obese-prone individuals differ in their responsiveness to circadian rhythms. We investigated both these hypotheses by measuring the core body temperature at regular and frequent intervals over a diurnal cycle, using indigestible temperature loggers in two breeds of canines known to differ in propensity to obesity, but prior to divergence in fatness. Greyhounds (obesity-resistant) and Labradors (obesity-prone) were fed indigestible temperature loggers. Gastrointestinal temperature was recorded at 10-min intervals for the period of transit of the logger. Diet, body condition score, activity level and environment were similar for both groups. Energy digestibility was also measured. The mean core body temperature in obesity-resistant dogs (38.27 °C) was slightly higher (P<0.001) than in obesity-prone dogs (38.18 °C) and the former had a greater variation (P<0.001) in 24h circadian core temperature. There were no differences in diet digestibility. Canines differing in propensity to obesity, but prior to its onset, differed little in mean core temperature, supporting similar findings in already-obese and lean humans. Obese-prone dogs were less variable in daily core temperature fluctuations, suggestive of a degree of circadian decoupling.
Schüller, Laura K; Heuwieser, Wolfgang
2016-08-01
The objectives of this study were to examine heat stress conditions at cow level and to investigate the relationship to the climate conditions at 5 different stationary locations inside a dairy barn. In addition, we compared the climate conditions at cow level between primiparous and multiparous cows for a period of 1 week after regrouping. The temperature-humidity index (THI) differed significantly between all stationary loggers. The lowest THI was measured at the window logger in the experimental stall and the highest THI was measured at the central logger in the experimental stall. The THI at the mobile cow loggers was 2·33 THI points higher than at the stationary loggers. Furthermore, the mean daily THI was higher at the mobile cow loggers than at the stationary loggers on all experimental days. The THI in the experimental pen was 0·44 THI points lower when the experimental cow group was located inside the milking parlour. The THI measured at the mobile cow loggers was 1·63 THI points higher when the experimental cow group was located inside the milking parlour. However, there was no significant difference for all climate variables between primiparous and multiparous cows. These results indicate, there is a wide range of climate conditions inside a dairy barn and especially areas with a great distance to a fresh air supply have an increased risk for the occurrence of heat stress conditions. Furthermore, the heat stress conditions are even higher at cow level and cows not only influence their climatic environment, but also generate microclimates within different locations inside the barn. Therefore climate conditions should be obtained at cow level to evaluate the heat stress conditions that dairy cows are actually exposed to.
Carter, Stephen P.; Bearhop, Stuart; Harrison, Xavier A.; Dall, Sasha R. X.; McDonald, Robbie A.; Delahay, Richard J.
2012-01-01
Knowledge of the way in which animals interact through social networks can help to address questions surrounding the ecological and evolutionary consequences of social organisation, and to understand and manage the spread of infectious diseases. Automated proximity loggers are increasingly being used to record interactions between animals, but the accuracy and reliability of the collected data remain largely un-assessed. Here we use laboratory and observational field data to assess the performance of these devices fitted to a herd of 32 beef cattle (Bos taurus) and nine groups of badgers (Meles meles, n = 77) living in the surrounding woods. The distances at which loggers detected each other were found to decrease over time, potentially related to diminishing battery power that may be a function of temperature. Loggers were highly accurate in recording the identification of contacted conspecifics, but less reliable at determining contact duration. There was a tendency for extended interactions to be recorded as a series of shorter contacts. We show how data can be manipulated to correct this discrepancy and accurately reflect observed interaction patterns by combining records between any two loggers that occur within a 1 to 2 minute amalgamation window, and then removing any remaining 1 second records. We make universally applicable recommendations for the effective use of proximity loggers, to improve the validity of data arising from future studies. PMID:22745704
Helmuth, Brian; Choi, Francis; Matzelle, Allison; Torossian, Jessica L.; Morello, Scott L.; Mislan, K.A.S.; Yamane, Lauren; Strickland, Denise; Szathmary, P. Lauren; Gilman, Sarah E.; Tockstein, Alyson; Hilbish, Thomas J.; Burrows, Michael T.; Power, Anne Marie; Gosling, Elizabeth; Mieszkowska, Nova; Harley, Christopher D.G.; Nishizaki, Michael; Carrington, Emily; Menge, Bruce; Petes, Laura; Foley, Melissa M.; Johnson, Angela; Poole, Megan; Noble, Mae M.; Richmond, Erin L.; Robart, Matt; Robinson, Jonathan; Sapp, Jerod; Sones, Jackie; Broitman, Bernardo R.; Denny, Mark W.; Mach, Katharine J.; Miller, Luke P.; O’Donnell, Michael; Ross, Philip; Hofmann, Gretchen E.; Zippay, Mackenzie; Blanchette, Carol; Macfarlan, J.A.; Carpizo-Ituarte, Eugenio; Ruttenberg, Benjamin; Peña Mejía, Carlos E.; McQuaid, Christopher D.; Lathlean, Justin; Monaco, Cristián J.; Nicastro, Katy R.; Zardi, Gerardo
2016-01-01
At a proximal level, the physiological impacts of global climate change on ectothermic organisms are manifest as changes in body temperatures. Especially for plants and animals exposed to direct solar radiation, body temperatures can be substantially different from air temperatures. We deployed biomimetic sensors that approximate the thermal characteristics of intertidal mussels at 71 sites worldwide, from 1998-present. Loggers recorded temperatures at 10–30 min intervals nearly continuously at multiple intertidal elevations. Comparisons against direct measurements of mussel tissue temperature indicated errors of ~2.0–2.5 °C, during daily fluctuations that often exceeded 15°–20 °C. Geographic patterns in thermal stress based on biomimetic logger measurements were generally far more complex than anticipated based only on ‘habitat-level’ measurements of air or sea surface temperature. This unique data set provides an opportunity to link physiological measurements with spatially- and temporally-explicit field observations of body temperature. PMID:27727238
NASA Astrophysics Data System (ADS)
Helmuth, Brian; Choi, Francis; Matzelle, Allison; Torossian, Jessica L.; Morello, Scott L.; Mislan, K. A. S.; Yamane, Lauren; Strickland, Denise; Szathmary, P. Lauren; Gilman, Sarah E.; Tockstein, Alyson; Hilbish, Thomas J.; Burrows, Michael T.; Power, Anne Marie; Gosling, Elizabeth; Mieszkowska, Nova; Harley, Christopher D. G.; Nishizaki, Michael; Carrington, Emily; Menge, Bruce; Petes, Laura; Foley, Melissa M.; Johnson, Angela; Poole, Megan; Noble, Mae M.; Richmond, Erin L.; Robart, Matt; Robinson, Jonathan; Sapp, Jerod; Sones, Jackie; Broitman, Bernardo R.; Denny, Mark W.; Mach, Katharine J.; Miller, Luke P.; O'Donnell, Michael; Ross, Philip; Hofmann, Gretchen E.; Zippay, Mackenzie; Blanchette, Carol; Macfarlan, J. A.; Carpizo-Ituarte, Eugenio; Ruttenberg, Benjamin; Peña Mejía, Carlos E.; McQuaid, Christopher D.; Lathlean, Justin; Monaco, Cristián J.; Nicastro, Katy R.; Zardi, Gerardo
2016-10-01
At a proximal level, the physiological impacts of global climate change on ectothermic organisms are manifest as changes in body temperatures. Especially for plants and animals exposed to direct solar radiation, body temperatures can be substantially different from air temperatures. We deployed biomimetic sensors that approximate the thermal characteristics of intertidal mussels at 71 sites worldwide, from 1998-present. Loggers recorded temperatures at 10-30 min intervals nearly continuously at multiple intertidal elevations. Comparisons against direct measurements of mussel tissue temperature indicated errors of ~2.0-2.5 °C, during daily fluctuations that often exceeded 15°-20 °C. Geographic patterns in thermal stress based on biomimetic logger measurements were generally far more complex than anticipated based only on ‘habitat-level’ measurements of air or sea surface temperature. This unique data set provides an opportunity to link physiological measurements with spatially- and temporally-explicit field observations of body temperature.
Zacour, Brian M; Pandey, Preetanshu; Subramanian, Ganeshkumar; Gao, Julia Z; Nikfar, Faranak
2014-06-01
The objective of this study was to determine the impact that the micro-environment, as measured by PyroButton data loggers, experienced by tablets during the pan coating unit operation had on the layer adhesion of bilayer tablets in open storage conditions. A full factorial design of experiments (DOE) with three center points was conducted to study the impact of final tablet hardness, film coating spray rate and film coating exhaust temperature on the delamination tendencies of bilayer tablets. PyroButton data loggers were placed (fixed) at various locations in a pan coater and were also allowed to freely move with the tablet bed to measure the micro-environmental temperature and humidity conditions of the tablet bed. The variance in the measured micro-environment via PyroButton data loggers accounted for 75% of the variance in the delamination tendencies of bilayer tablets on storage (R(2 )= 0.75). A survival analysis suggested that tablet hardness and coating spray rate significantly impacted the delamination tendencies of the bilayer tablets under open storage conditions. The coating exhaust temperature did not show good correlation with the tablets' propensity to crack indicating that it was not representative of the coating micro-environment. Models created using data obtained from the PyroButton data loggers outperformed models created using primary DOE factors in the prediction of bilayer tablet strength, especially upon equipment or scale transfers. The coating micro-environment experienced by tablets during the pan coating unit operation significantly impacts the strength of the bilayer interface of tablets on storage.
Real-time Remote Data Online For Norris Geyser Basin in Yellowstone National Park
NASA Astrophysics Data System (ADS)
Perry, J. E.; Lowenstern, J. B.; Clor, L.; Cervelli, P. F.; Allen, S. T.; Heasler, H.; Moloney, T.
2010-12-01
Perry, John, Lowenstern, Jacob, Cervelli, Peter, Clor, Laura, Heasler, Henry, Allen, Scott, Moloney, Tim During June 2010, ten 900MHz wireless temperature data loggers (nodes) were installed around the Norris Geyser Basin to monitor geothermal features, streams and soil temperatures. The loggers can provide near real-time updates on temperature variations within 0.2 deg C due to hydrothermal discharges or subsurface fluid migration. Each sensor node is programmed to measure the temperature every two minutes and automatically upload data to the base station computer daily. The hardware consists of a waterproof case containing an M5 logger (made by Marathon Products, Inc.®) with internal memory, lithium D-cell batteries and a 900 MHz, 1-W-transceiver and 5 meter long Teflon-coated probe with a thermistor sensor. Tethered stub or panel antennas are oriented to optimize signal strength to the base station near the Norris Museum. A 0.61 meter-long base-station antenna located 10m high provides signal to the furthest node over 850 meters away with most being “line-of-sight”. A 20-meter coaxial cable and lightning grounding wire connects the base-station antenna to an Ethernet-radio connected to the YNP local-area network. A server located 26-km north at Mammoth Hot Springs requests data at regular intervals (normally daily), archives the information, and then sends it to the USGS for further archiving and internet distribution. During periods of unusual hydrothermal behavior, data can be requested as needed, and it is possible to set user-programmable alarm limits for notification. The RF network is designed to monitor changes from three different sub-basins at Norris (Gray Lakes, Steamboat-Echinus and Porcelain Basin), the main Tantalus Creek drainage, and five individual thermal features (Constant, Porkchop, Steamboat and Echinus Geysers, and Opalescent Spring). The logger installed in Nuphar Lake provides ambient temperatures controlled solely by local meteorological conditions. Soil temperature is measured near Vixen Geyser. The system will permit land managers, scientists and the public to keep track of changes to the hydrothermal system, including geyser eruptions, periodic basin-wide disturbances, or fluid-release events that may accompany or follow seismic activity.
A note on the collection and cleaning of water temperature data
Colin Sowder; E. Ashley Steel
2012-01-01
Inexpensive remote temperature data loggers have allowed for a dramatic increase of data describing water temperature regimes. This data is used in understanding the ecological functioning of natural riverine systems and in quantifying changes in these systems. However, an increase in the quantity of yearly temperature data necessitates complex data management,...
NASA Astrophysics Data System (ADS)
Nagendra, U.; Peterson, C.
2013-12-01
Forest disturbances such as tornadoes are expected to raise soil temperatures and increase soil respiration. Opening canopy gaps allows solar radiation to heat the forest floor, and damaged plant roots provide fuel for decomposition. Patches of disturbed forest can range from low severity (some defoliation, broken branches) to high severity (uprooted or snapped trees). Disturbance severity affects plant population and community processes, such as regeneration mode, species diversity, and community structure. We expect disturbance severity to also affect ecosystem processes such as soil respiration. Severe disturbances cause more distinct, and often larger, canopy gaps than mild disturbances, and damage more standing biomass, both above- and below-ground. We would expect these larger gaps and greater litter amounts to increase soil temperature and respiration in more severely disturbed forest patches. In April 2011, a moderate (EF-3) tornado damaged portions of the Chattahoochee National Forest in NE Georgia, USA. Our lab has been characterizing the damage and regeneration in sections of the forest since summer 2011. In Spring 2013, we installed 4 iButton temperature sensors in each of 14 plots across a range of disturbance severity (for a total of 56 sensors). Severity was determined by percent of initial tree basal area downed by the tornado, and ranged from 8% to 100% basal area down. The iButtons monitored soil temperature at a depth of 5 cm every hour for 85 days. In July 2013, integrated 24-hour soil respiration was measured at the same locations using soda lime absorption in sealed PVC collars. Soil temperature at 5 cm averaged 12.66 °C. Contrary to expectations, average daily temperatures did not increase with greater plot damage severity (R2 = 0.001). Daily variation was only slightly higher in plots of very high severity. Overall, soil temperatures appeared to have returned to pre-disturbance temperatures more quickly than expected. Results for upcoming months will be presented at the meeting. Soil respiration was relatively high in all plots (4.49 +/-1.19 g C m-2 hr-1). Contrary to expectations, respiration did not vary significantly with plot damage severity (R2 = 0.0676). The temperature and respiration data together suggest potentially rapid ecosystem recovery after these types of wind disturbances. The flush of understory growth in open patches may insulate the forest floor from solar radiation, even though the forest canopy is still open. These unexpected preliminary results may indicate that ecosystem processes in southern forests are more resilient to disturbances than previously thought. Although forests become carbon sinks immediately after disturbances, they may return to carbon neutral or sink status relatively quickly, given the right circumstances.
Inexpensive Open-Source Data Logging in the Field
NASA Astrophysics Data System (ADS)
Wickert, A. D.
2013-12-01
I present a general-purpose open-source field-capable data logger, which provides a mechanism to develop dense networks of inexpensive environmental sensors. This data logger was developed as a low-power variant of the Arduino open-source development system, and is named the ALog ("Arduino Logger") BottleLogger (it is slim enough to fit inside a Nalgene water bottle) version 1.0. It features an integrated high-precision real-time clock, SD card slot for high-volume data storage, and integrated power switching. The ALog can interface with sensors via six analog/digital pins, two digital pins, and one digital interrupt pin that can read event-based inputs, such as those from a tipping-bucket rain gauge. We have successfully tested the ALog BottleLogger with ultrasonic rangefinders (for water stage and snow accumulation and melt), temperature sensors, tipping-bucket rain gauges, soil moisture and water potential sensors, resistance-based tools to measure frost heave, and cameras that it triggers based on events. The source code for the ALog, including functions to interface with a a range of commercially-available sensors, is provided as an Arduino C++ library with example implementations. All schematics, circuit board layouts, and source code files are open-source and freely available under GNU GPL v3.0 and Creative Commons Attribution-ShareAlike 3.0 Unported licenses. Through this work, we hope to foster a community-driven movement to collect field environmental data on a budget that permits citizen-scientists and researchers from low-income countries to collect the same high-quality data as researchers in wealthy countries. These data can provide information about global change to managers, governments, scientists, and interested citizens worldwide. Watertight box with ALog BottleLogger data logger on the left and battery pack with 3 D cells on the right. Data can be collected for 3-5 years on one set of batteries.
Development of Thermal Radiation Experiments Kit Based on Data Logger for Physics Learning Media
NASA Astrophysics Data System (ADS)
Permana, H.; Iswanto, B. H.
2018-04-01
Thermal Radiation Experiments Kit (TREK) based on data logger for physics learning media was developed. TREK will be used as a learning medium on the subject of Temperature and Heat to explain the concept of emissivity of a material in grade XI so that it can add variations of experiments which are commonly done such as thermal expansion, transfer of thermal energy (conduction, convection, and radiation), and specific heat capacity. DHT11 sensor is used to measure temperature and microcontroller Arduino-uno used as data logger. The object tested are in the form of coated glass thin films and aluminum with different colors. TREK comes with a user manual and student worksheet (LKS) to make it easier for teachers and students to use. TREK was developed using the ADDIE Development Model (Analyze, Design, Development, Implementation, and Evaluation). And validated by experts, physics teachers, and students. Validation instrument is a questionnaire with a five-item Likert response scale with reviewed aspect coverage: appropriate content and concepts, design, and user friendly. The results showed that TREK was excellent (experts 88.13%, science teachers 95.68%, and students 85.77%).
Physical characterization of intertidal estuarine plant habitats over time may reveal distribution-limiting thresholds. Temperature data from loggers embedded in sediment in transects crossing Zostera marina and Z. japonica habitats in lower Yaquina Bay, Oregon display signific...
Shaffer, Scott A.; Clatterbuck, Corey A.; Kelsey, Emma C.; Naiman, Alex D.; Young, Lindsay C.; VanderWerf, Eric A.; Warzybok, Pete; Bradley, Russell; Jahncke, Jaime; Bower, Geoff C.
2014-01-01
Egg turning is unique to birds and critical for embryonic development in most avian species. Technology that can measure changes in egg orientation and temperature at fine temporal scales (1 Hz) was neither readily available nor small enough to fit into artificial eggs until recently. Here we show the utility of novel miniature data loggers equipped with 3-axis (i.e., triaxial) accelerometers, magnetometers, and a temperature thermistor to study egg turning behavior in free-ranging birds. Artificial eggs containing egg loggers were deployed in the nests of three seabird species for 1–7 days of continuous monitoring. These species (1) turned their eggs more frequently (up to 6.5 turns h−1) than previously reported for other species, but angular changes were often small (1–10° most common), (2) displayed similar mean turning rates (ca. 2 turns h−1) despite major differences in reproductive ecology, and (3) demonstrated distinct diurnal cycling in egg temperatures that varied between 1.4 and 2.4°C. These novel egg loggers revealed high-resolution, three-dimensional egg turning behavior heretofore never measured in wild birds. This new form of biotechnology has broad applicability for addressing fundamental questions in avian breeding ecology, life history, and development, and can be used as a tool to monitor birds that are sensitive to disturbance while breeding. PMID:24887441
1992-10-01
MSFC Test Engineer performing a functional test on the TES. The TES can be operated as a refrigerator, with a minimum set point temperature of 4.0 degrees C, or as an incubator, with a maximum set point temperature 40.0 degrees C of the set point. The TES can be set to maintain a constant temperature or programmed to change temperature settings over time, internal temperature recorded by a date logger.
NASA Astrophysics Data System (ADS)
Lee, Raymond W.; Robert, Katleen; Matabos, Marjolaine; Bates, Amanda E.; Juniper, S. Kim
2015-12-01
A significant focus of hydrothermal vent ecological studies has been to understand how species cope with various stressors through physiological tolerance and biochemical resistance. Yet, the environmental conditions experienced by vent species have not been well characterized. This objective requires continuous observations over time intervals that can capture environmental variability at scales that are relevant to animals. We used autonomous temperature logger arrays (four roughly parallel linear arrays of 12 loggers spaced every 10-12 cm) to study spatial and temporal variations in the thermal regime experienced by hydrothermal vent macrofauna at a diffuse flow vent. Hourly temperatures were recorded over eight months from 2010 to 2011 at Grotto vent in the Main Endeavour vent field on the Juan de Fuca Ridge, a focus area of the Ocean Networks Canada cabled observatory. The conspicuous animal assemblages in video footage contained Ridgeia piscesae tubeworms, gastropods (primarily Lepetodrilus fucensis), and polychaetes (polynoid scaleworms and the palm worm Paralvinella palmiformis). Two dimensional spatial gradients in temperature were generally stable over the deployment period. The average temperature recorded by all arrays, and in some individual loggers, revealed distinctive fluctuations in temperature that often corresponded with the tidal cycle. We postulate that this may be related to changes in bottom currents or fluctuations in vent discharge. A marked transient temperature increase lasting over a period of days was observed in April 2011. While the distributions and behavior of Juan de Fuca Ridge vent invertebrates may be partially constrained by environmental temperature and temperature tolerance, except for the one transient high-temperature event, observed fluid temperatures were generally similar to the thermal preferences for some species, and typically well below lethal temperatures for all species. Average temperatures of the four arrays ranged from 4.1 to 11.0 °C during the deployment, indicating that on an hourly timescale the temperature conditions in this tubeworm community were fairly moderate and stable. The generality of these findings and behavioral responses of vent organisms to predictable rhythmicity and non-periodic temperature shifts are areas for further investigation.
NASA Astrophysics Data System (ADS)
Ropert-Coudert, Yan; Knott, Nathan; Chiaradia, André; Kato, Akiko
2007-02-01
It is crucial in any bio-logging study to establish the potential effect that attachment of loggers may have on the animal. This ensures that the behaviour monitored by the loggers has a biological relevance, as well as for ethical reasons. Evaluation of the effects of externally attached loggers shows that they increase the drag of swimming animals and increase their energy expenditure. Nevertheless, little research has been done on the effects of size or position of such loggers. In this study, we tested whether the size (i.e. large: 4.9% versus small: 3.4% of the bird's frontal area) or the place of attachment (middle versus lower back) affected the diving behaviour of male and female little penguins ( Eudyptula minor). The positioning of the data logger on the middle or lower section of little penguins' back had little, if no effect, on the diving variables measured in this study. Size of the loggers, however, had strong effects. Birds with large loggers made shorter dives and reached shallower depths than those with small loggers. In addition, birds with large loggers made more dives probably to compensate for the extra cost of carrying a large logger. The measured variables also differed between the sexes, with males diving deeper and longer than females. Logger size had a sex-specific effect on the trip duration and descent speed, with males equipped with large loggers staying longer at sea than those with small loggers, and females with large loggers descending faster than those with small loggers. From our results, it appears that effects of logger position do not exist or are very small in comparison with the effects of logger size. The results of the current study indicate that the effects of size of loggers be evaluated more commonly in bio-logging research into the diving activity of free-ranging birds.
Characterisation of regional skin temperatures in recreational surfers wearing a 2-mm wetsuit.
Corona, Luis J; Simmons, Grant H; Nessler, Jeff A; Newcomer, Sean C
2018-05-01
The purpose of this study was to investigate skin temperatures across surfers' bodies while wearing a wetsuit during recreational surfing. Forty-six male recreational surfers participated in this study. Participants were instrumented with eight wireless iButton thermal sensors for the measurement of skin temperature, a Polar RCX5 heart rate monitor and a 2-mm full wetsuit. Following instrumentation, participants were instructed to engage in recreational surfing activities as normal. Significant differences (p < 0.001) in skin temperature (T sk ) were found across the body while wearing a wetsuit during recreational surfing. In addition, regional skin temperature changed across the session for several regions of the body (p < 0.001), and the magnitude of these changes varied significantly between regions. We show for the first time that significant differences exist in skin temperature across the body while wearing a wetsuit during a typical recreational surfing session. These findings may have implications for future wetsuit design. Practitioner Summary: This study investigated the impact of wearing a wetsuit during recreational surfing on regional skin temperatures. Results from this study suggest that skin temperatures differ significantly across the body while wearing a 2-mm wetsuit during recreational surfing. These findings may have implications for future wetsuit design.
Functional Test on (TES) Thermal Enclosure System
NASA Technical Reports Server (NTRS)
1992-01-01
MSFC Test Engineer performing a functional test on the TES. The TES can be operated as a refrigerator, with a minimum set point temperature of 4.0 degrees C, or as an incubator, with a maximum set point temperature 40.0 degrees C of the set point. The TES can be set to maintain a constant temperature or programmed to change temperature settings over time, internal temperature recorded by a date logger.
Weatherbee, Courtney R.; Pechal, Jennifer L.; Stamper, Trevor; Benbow, M. Eric
2017-01-01
Common forensic entomology practice has been to collect the largest Diptera larvae from a scene and use published developmental data, with temperature data from the nearest weather station, to estimate larval development time and post-colonization intervals (PCIs). To evaluate the accuracy of PCI estimates among Calliphoridae species and spatially distinct temperature sources, larval communities and ambient air temperature were collected at replicate swine carcasses (N = 6) throughout decomposition. Expected accumulated degree hours (ADH) associated with Cochliomyia macellaria and Phormia regina third instars (presence and length) were calculated using published developmental data sets. Actual ADH ranges were calculated using temperatures recorded from multiple sources at varying distances (0.90 m–7.61 km) from the study carcasses: individual temperature loggers at each carcass, a local weather station, and a regional weather station. Third instars greatly varied in length and abundance. The expected ADH range for each species successfully encompassed the average actual ADH for each temperature source, but overall under-represented the range. For both calliphorid species, weather station data were associated with more accurate PCI estimates than temperature loggers associated with each carcass. These results provide an important step towards improving entomological evidence collection and analysis techniques, and developing forensic error rates. PMID:28375172
NASA Astrophysics Data System (ADS)
Bennett, K. E.; Cherry, J. E.; Hiemstra, C. A.; Bolton, W. R.
2013-12-01
Interior sub-Arctic Alaskan snow cover is rapidly changing and requires further study for correct parameterization in physically based models. This project undertook field studies during the 2013 snow melt season to capture snow depth, snow temperature profiles, and snow cover extent to compare with observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor at four different sites underlain by discontinuous permafrost. The 2013 melt season, which turned out to be the latest snow melt period on record, was monitored using manual field measurements (SWE, snow depth data collection), iButtons to record temperature of the snow pack, GoPro cameras to capture time lapse of the snow melt, and low level orthoimagery collected at ~1500 m using a Navion L17a plane mounted with a Nikon D3s camera. Sites were selected across a range of landscape conditions, including a north facing black spruce hill slope, a south facing birch forest, an open tundra site, and a high alpine meadow. Initial results from the adjacent north and south facing sites indicate a highly sensitive system where snow cover melts over just a few days, illustrating the importance of high resolution temporal data capture at these locations. Field observations, iButtons and GoPro cameras show that the MODIS data captures the melt conditions at the south and the north site with accuracy (2.5% and 6.5% snow cover fraction present on date of melt, respectively), but MODIS data for the north site is less variable around the melt period, owing to open conditions and sparse tree cover. However, due to the rapid melt rate trajectory, shifting the melt date estimate by a day results in a doubling of the snow cover fraction estimate observed by MODIS. This information can assist in approximating uncertainty associated with remote sensing data that is being used to populate hydrologic and snow models (the Sacramento Soil Moisture Accounting model, coupled with SNOW-17, and the Variable Infiltration Capacity hydrologic model) and provide greater understanding of error and resultant model sensitivities associated with regional observations of snow cover across the sub-Arctic boreal landscape.
Merello, Paloma; García-Diego, Fernando-Juan; Zarzo, Manuel
2012-11-28
Ariadne's house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.
Gungle, Bruce
2006-01-01
Frequency, timing, and duration of streamflow were monitored in 20 ephemeral-stream channels across the Sierra Vista Subwatershed of the Upper San Pedro Basin, southeastern Arizona, during an 18-month period. One channel (Walnut Gulch) had Agricultural Research Service streamflow-gaging stations in place. The sediments of the remaining 19 ephemeral-stream channels were instrumented with multiple temperature loggers along the channel lengths. A thermograph-interpretation technique was developed in order to determine frequency, timing, and duration of streamflow in these channels. Streamflow onset was characterized by exceedance of a critical minimum drop in temperature within the channel sediments during any 15-minute interval, whereas streamflow cessation was identified by the local temperature minimum that immediately followed the critical temperature drop. All data for the 18-month period from December 1, 2000, to May 31, 2002, were analyzed in terms of monsoon (June 1 to September 19) and nonmonsoon (September 20 to May 31) periods. Nonmonsoon precipitation during the 2000-2002 study period (excludes October and November 2000) was 82 percent and 39 percent of the 30-year average, respectively, whereas monsoon precipitation during 2001 was 99 percent of the 30-year average. Ephemeral streamflow was detected at least once during the monitoring period at 87 percent of the monitoring sites (45 of the 52 sites that returned useful data; includes 4 streamflow-gaging stations). The summer monsoon period accounted for 82 percent of all streamflow events by number and 71 percent of all events by total streamflow duration. Nonmonsoon streamflow events peaked in number, total streamflow duration, and mean streamflow duration midway between the Huachuca Mountains and the San Pedro River on the west side of the subwatershed. These three streamflow parameters dropped off sharply about 10 kilometers from the mountain front. The number and total duration of nonmonsoon streamflows on the east side of the subwatershed trended downward with increased distance from the mountain fronts. Monsoon streamflow events were more evenly distributed across the subwatershed than nonmonsoon events, and the number and duration of streamflows generally trended upward with distance from the mountain fronts. Additional years of data are needed to determine whether these patterns are consistent year to year, or were due to randomness in the spatial distribution of precipitation. Streamflows in three ephemeral-stream channels were analyzed in detail. More than two-thirds of the streamflow events detected in each of these channels occurred at no more than one monitoring site along the channel length. In only one of the three channels-Garden Canyon-was a streamflow event detected at all logger sites along its length. Five temperature loggers provided data from urbanized areas, and these loggers detected streamflow more than 50 percent more often and of a duration nearly three times greater than did temperature loggers across the rural parts of the subwatershed. Because historical records do not indicate that more precipitation occurs in the urbanized area than in the rural areas, the increased frequency of flow detection in the urban area is attributed to an increase in runoff from the impervious surfaces throughout the urbanized area.
Time Series Analysis of Water Level and Temperature in the St Louis River Estuary
Pressure and temperature loggers were deployed at 9 sites in the St Louis River estuary between 6/23 10/31 2011. A reference sensor was place on the shore to correct pressure data. Sensors were paced at <1 m depth in Allouez Bay, Superior Bay, near Hearding Island, WLSSD Bay, th...
Comparison of Vertical Soundings and Sidewall Air Temperature Measurements in a Small Alpine Basin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteman, Charles D.; Eisenbach, Stefan; Pospichal, Bernhard
2004-11-01
Tethered balloon soundings from two sites on the floor of a 1-km diameter limestone sinkhole in the Eastern Alps are compared with pseudo-vertical temperature ‘soundings’ from three lines of temperature data loggers on the basin’s northwest, southwest and southeast sidewalls. Under stable nighttime conditions with low background winds, the pseudo-vertical profiles from all three lines were good proxies for free air temperature soundings over the basin center, with a mean nighttime cold temperature bias of about 0.4°C and a standard deviation of 0.4°C. Cold biases were highest in the upper basin where relatively warm air subsides to replace air thatmore » spills out of the basin through the lowest altitude saddle. On a windy night, standard deviations increased to 1 - 2°C. After sunrise, the varying exposures of the data loggers to sunlight made the pseudo-vertical profiles less useful as proxies for free air soundings. The good correspondence between sidewall and free air temperatures during high static stability conditions suggests that sidewall soundings will prove useful in monitoring temperatures and vertical temperature gradients in the sinkhole. The sidewall soundings can produce more frequent profiles at less cost than tethersondes or rawinsondes, and provide valuable advantages for some types of meteorological analyses.« less
Vegetation placement for summer built surface temperature moderation in an urban microclimate.
Millward, Andrew A; Torchia, Melissa; Laursen, Andrew E; Rothman, Lorne D
2014-06-01
Urban vegetation can mitigate increases in summer air temperature by reducing the solar gain received by buildings. To quantify the temperature-moderating influence of city trees and vine-covered buildings, a total of 13 pairs of temperature loggers were installed on the surfaces of eight buildings in downtown Toronto, Canada, for 6 months during the summer of 2008. One logger in each pair was shaded by vegetation while the other measured built surface temperature in full sunlight. We investigated the temperature-moderating benefits of solitary mature trees, clusters of trees, and perennial vines using a linear-mixed model and a multiple regression analysis of degree hour difference. We then assessed the temperature-moderating effect of leaf area, plant size and proximity to building, and plant location relative to solar path. During a period of high solar intensity, we measured an average temperature differential of 11.7 °C, with as many as 10-12 h of sustained cooler built surface temperatures. Vegetation on the west-facing aspect of built structures provided the greatest temperature moderation, with maximum benefit (peak temperature difference) occurring late in the afternoon. Large mature trees growing within 5 m of buildings showed the greatest ability to moderate built surface temperature, with those growing in clusters delivering limited additional benefit compared with isolated trees. Perennial vines proved as effective as trees at moderating rise in built surface temperature to the south and west sides of buildings, providing an attractive alternative to shade trees where soil volume and space are limited.
Vegetation Placement for Summer Built Surface Temperature Moderation in an Urban Microclimate
NASA Astrophysics Data System (ADS)
Millward, Andrew A.; Torchia, Melissa; Laursen, Andrew E.; Rothman, Lorne D.
2014-06-01
Urban vegetation can mitigate increases in summer air temperature by reducing the solar gain received by buildings. To quantify the temperature-moderating influence of city trees and vine-covered buildings, a total of 13 pairs of temperature loggers were installed on the surfaces of eight buildings in downtown Toronto, Canada, for 6 months during the summer of 2008. One logger in each pair was shaded by vegetation while the other measured built surface temperature in full sunlight. We investigated the temperature-moderating benefits of solitary mature trees, clusters of trees, and perennial vines using a linear-mixed model and a multiple regression analysis of degree hour difference. We then assessed the temperature-moderating effect of leaf area, plant size and proximity to building, and plant location relative to solar path. During a period of high solar intensity, we measured an average temperature differential of 11.7 °C, with as many as 10-12 h of sustained cooler built surface temperatures. Vegetation on the west-facing aspect of built structures provided the greatest temperature moderation, with maximum benefit (peak temperature difference) occurring late in the afternoon. Large mature trees growing within 5 m of buildings showed the greatest ability to moderate built surface temperature, with those growing in clusters delivering limited additional benefit compared with isolated trees. Perennial vines proved as effective as trees at moderating rise in built surface temperature to the south and west sides of buildings, providing an attractive alternative to shade trees where soil volume and space are limited.
A new data logger for integrated geophysical monitoring
NASA Astrophysics Data System (ADS)
Orazi, Massimo; Peluso, Rosario; Caputo, Antonio; Giudicepietro, Flora; Martini, Marcello
2015-04-01
GILDA digital recorder is a data logger developed at Osservatorio Vesuviano (INGV). It provides excellent data quality with low power consumption and low production cost. It is widely used in the multi-parametric monitoring networks of Neapolitan volcanoes and Stromboli volcano. We have improved the characteristics of GILDA recorder to realize a robust user-oriented acquisition system for integrated geophysical monitoring. We have designed and implemented new capabilities concerning the use of the low rate channels to get data of environmental parameters of the station. We also improved the stand-alone version of the data logger. This version can be particularly useful for scientific experiments and to rapidly upgrade permanent monitoring networks. Furthermore, the local storage can be used as back-up for the monitoring systems in continuous transmission, in case of failure of the transmission system. Some firmware changes have been made in order to improve the performance of the instrument. In particular, the low rate acquisition channels were conditioned to acquire internal parameters of the recorder such as the temperature and voltage. A prototype of the new version of the logger is currently installed at Campi Flegrei for a experimental application. Our experiment is aimed at testing the new version of GILDA data logger in multi-board configuration for multiparametric acquisitions. A second objective of the experiment is the comparison of the recorded data with geochemical data acquired by a multiparametric geochemical station to investigate possible correlations between seismic and geochemical parameters. The target site of the experiment is "Bocca Grande" fumarole in Solfatara volcano. By exploiting the modularity of GILDA, for the experiment has been realized an acquisition system based on three dataloggers for a total of 12 available channels. One of GILDA recorders is the Master and the other two are Slaves. The Master is responsible for the initial configuration of the GPS receiver for timing data. The two data loggers configured in slave mode await the end of the initial configuration and then receive the GPS timing data and PPS from the Master. This allows you to use one GPS receiver and optimize power consumption. The whole system is configured to continuously transmit data via WiFi and to locally store data.
Frederick A. Bierlmaler; Arthur McKee
1989-01-01
This report describes the primary meteorological station at the H.J. Andrews Experimental Forest (elev. 426 m, lat. 44°15' N., long. 122°10' W.) in the Willamette National Forest, the automatic digital data logger, sensors, and data-processing procedures used in measuring air temperature, dewpoint temperature, windspeed, precipitation, and solar radiation....
Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa.
Naicker, Nisha; Teare, June; Balakrishna, Yusentha; Wright, Caradee Yael; Mathee, Angela
2017-11-18
Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb) from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types ( p < 0.0001). Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.
Development and testing of a tensiologger: a tensiometer with a built-in datalogger
NASA Astrophysics Data System (ADS)
Tuts, Valentijn; Ronchi, Benedicta; Diels, Jan
2014-05-01
Water-filled tensiometers are widely used for measuring matric potential in the range between 0 and approximately -90kPa in soils. When placed in variably-saturated soil horizons, they correctly measure the pressure head both in unsaturated and saturated conditions. Modern tensiometers consist of a porous ceramic cup filled with water that is connected to a pressure transducer. Tensiometers are commercially available in different models, and can be logged with data loggers. Logging requires either cabling to connect the tensiometers to a data logger, or a wireless connection. Cables hamper field operations and can be unpractical because of the distances involved. Commercially available systems with wireless data communication with a central datalogger do not come cheap. We therefore developed a simple water-filled tensiometer with a build-in datalogger, which we called a tensiologger. The tensiologger is assembled using a porous ceramic cup (Al2O3 sinter material with bubble point > 15 bar, UMS GmbH Munich, Germany) filled with degassed demineralised water for transferring the pressure head to the pressure transducer. This cup is screwed onto a small housing with a capsulated logger circuit consisting of a pressure transducer, a temperature sensor for temperature measurement and for temperature correction of the pressure transducer, a memory for 32k measurements, and a microcontroller for logging the data. This loggercircuit is screwed onto an extension tube of 25 mm diameter that contains a replaceable battery and an optical interface at the top (extending from the soil surface). The data can be retrieved from the logger by means of a readout unit that is placed over the optical interface. This readout unit is connected to a USB port of a portable PC with logger software developed in Visual Basic. The cost of all parts including the printed circuit board is 220€ (excluding labour cost for making screw connections and assembling). The tensiologger was tested over a 8-month period at a grassland site in Blegny, Belgium. We installed tensiologgers at three different locations along a slope and at 15, 45, and 75 cm depth. At the lowest topographic location, we measured groundwater levels with a diver, which allowed us to know when soil is saturated. During or after rainfall events, tension peaks were detected at all depths with a little retardation along the profile, and positive pressure head values were measured as the soil became saturated. Higher on the slope, where drilling problems impede piezometer installation, positive tensions were measured sporadically at 75 cm and 45 cm depth. In dry periods, air bubbles developed in the cups of the shallow tensiologgers, and so cups had to be refilled with degassed water.
2012-01-01
Background Ariadne’s house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Results Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. Conclusions The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments. PMID:23190798
A preliminary evaluation of a reusable digital sterilization indicator prototype.
Puttaiah, R; Griggs, J; D'Onofrio, M
2014-09-01
Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles in an autoclave. In this study, the final batch of the DS1922F prototype data logger was found to be robust in withstanding the challenge of 600 autoclave cycles, with a mean lifetime of more than 450 cycles, multiple times more than prescribed number of cycles. Instrument reprocessing is among the important aspects of infection control. While stringent procedures are followed in instrument reprocessing within the clinic in assuring patient safety, regular use of sterilization process indicators and periodic biological validation of the sterilizer's performance is necessary. Chemical indicators for use in Autoclaves provide information on whether the particular cycle's parameters were achieved but do not provide at what specific point in time or temperature the failure occurred. Data loggers and associated reader software as the tested prototype in this evaluation (DS1922F), are designed to provide continuous information on time and temperature of the prescribed cycle. Data loggers provide immediate information on the process as opposed to Biological Indicators that take from days to a week in obtaining a confirmatory result. Further, many countries do not have the sterilization monitoring service infrastructure to meet the demands of the end users. In the absence of sterilization monitoring services, use of digital data loggers for each sterilization cycle is more pragmatic.
Armstrong, Jonathan B.; Ward, Eric J.; Schindler, Daniel E.; Lisi, Peter J.
2016-01-01
As climate change increases maximal water temperatures, behavioural thermoregulation may be crucial for the persistence of coldwater fishes, such as salmonids. Although myriad studies have documented behavioural thermoregulation in southern populations of salmonids, few if any have explored this phenomenon in northern populations, which are less likely to have an evolutionary history of heat stress, yet are predicted to experience substantial warming. Here, we treated a rare heat wave as a natural experiment to test whether wild sockeye salmon (Oncorhynchus nerka) at the northern extent of their primary range (60° latitude) can thermoregulate in response to abnormally high thermal conditions. We tagged adult sockeye salmon with temperature loggers as they staged in a lake epilimnion prior to spawning in small cold streams (n = 40 recovered loggers). As lake surface temperatures warmed to physiologically suboptimal levels (15–20°C), sockeye salmon thermoregulated by moving to tributary plumes or the lake metalimnion. A regression of fish body temperature against lake surface temperature indicated that fish moved to cooler waters when the epilimnion temperature exceeded ~12°C. A bioenergetics model suggested that the observed behaviour reduced daily metabolic costs by as much as ~50% during the warmest conditions (18–20°C). These results provide rare evidence of cool-seeking thermoregulation at the poleward extent of a species range, emphasizing the potential ubiquity of maximal temperature constraints and the functional significance of thermal heterogeneity for buffering poikilotherms from climate change. PMID:27729980
Unmanned Aerial System Aids Dry-season Stream Temperature Sensing
NASA Astrophysics Data System (ADS)
Chung, M.; Detweiler, C.; Higgins, J.; Ore, J. P.; Dralle, D.; Thompson, S. E.
2016-12-01
In freshwater ecosystems, temperature affects biogeochemistry and ecology, and is thus a primary physical determinant of habitat quality. Measuring temperatures in spatially heterogeneous water bodies poses a serious challenge to researchers due to constraints associated with currently available methods: in situ loggers record temporally continuous temperature measurements but are limited to discrete spatial locations, while distributed temperature and remote sensing provide fine-resolution spatial measurements that are restricted to only two-dimensions (i.e. streambed and surface, respectively). Using a commercially available quadcopter equipped with a 6m cable and temperature-pressure sensor system, we measured stream temperatures at two confluences at the South Fork Eel River, where cold water inputs from the tributary to the mainstem create thermal refugia for juvenile salmonids during the dry season. As a mobile sensing platform, unmanned aerial systems (UAS) can facilitate quick and repeated sampling with minimal disturbance to the ecosystem, and their datasets can be interpolated to create a three-dimensional thermal map of a water body. The UAS-derived data was compared to data from in situ data loggers to evaluate whether the UAS is better able to capture fine-scale temperature dynamics at each confluence. The UAS has inherent limitations defined by battery life and flight times, as well as operational constraints related to maneuverability under wind and streamflow conditions. However, the platform is able to serve as an additional field tool for researchers to capture complex thermal structures in water bodies.
Temperature estimation for the most upper part of magmatic chamber of the Elbrus volcano
NASA Astrophysics Data System (ADS)
Likhodeev, Dmitry
2013-04-01
The results of theoretical and experimental studies on thermal processes in the Elbrus volcanic center and adjacent territories are presented. Distributed temperature measurements on the Elbrus volcano and near the Maloye Azau glacier by means of temperature data loggers («High Capacity Temperature Loggers iButton» and «Rejim-avtomat-termo-10-100») have been performed. The comparative time series analysis is provided. On the basis of the Geophysical Observatory in Northern Caucasus, in the laboratory located some 20 km from the Elbrus volcano in the tunnel at a depth of 4 km the array of temperature sensors has been deployed. Results of continuous observations over variations of underground temperatures, including pin-point measurements in the vicinity of sources of carbonaceous mineral waters are presented and discussed. Temperature estimations for the most upper part of the shallow magmatic chamber of the of the Elbrus volcano were obtained on the basis of experimental measurements in the 180-meter deep borehole drilled through the glacier on the western plateau of Mount Elbrus. The estimations of deep temperatures have confirmed the possibility of existence of the magmatic chamber at depths of 0-1 km below sea level. At the same time the magnitudes of local heat flux were identified with enhanced precision. Thus, the original scientific results provide significant extension to our knowledge on possible resumption of volcanic activity in the vicinity of Mount Elbrus.
Information needs for increasing log transport efficiency
Timothy P. McDonald; Steven E. Taylor; Robert B. Rummer; Jorge Valenzuela
2001-01-01
Three methods of dispatching trucks to loggers were tested using a log transport simulation model: random allocation, fixed assignment of trucks to loggers, and dispatch based on knowledge of the current status of trucks and loggers within the system. This 'informed' dispatch algorithm attempted to minimize the difference in time between when a logger would...
ERIC Educational Resources Information Center
Barrett, Scott M.; Bolding, M. Chad; Munsell, John F.
2012-01-01
Virginia's SHARP logger program is a Cooperative Extension program currently providing training to over 1,500 loggers, foresters, and others. We conducted a mail survey of SHARP loggers to characterize program participants, assess programming needs, and evaluate program effectiveness. Results indicate a diverse group of participants in terms of…
Fuel supply structure of wood-fired power plants in the Northeast: Loggers' perspectives
Neil K. Huyler; Neil K. Huyler
1989-01-01
A study of loggers' perceptions of the impact of large biomass demand centers on the forest resource base in the Northeast indicated that most loggers strongly believe that the post-harvest stand has improved. However, the impact of whole-tree chipping on the forest resource base was not made clear from the loggers' survey.
INFLUENCE OF RESIDENTIAL HVAC DUTY CYCLE ON INDOOR AIR QUALITY
Measurements of duty cycle, the fraction of time the heating and cooling (HVAC) system was operating, were made in homes during the spring season of the RTP Particulate Matter Panel Study and the Tampa Asthmatic Children's Study. A temperature sensor/logger placed on an outlet...
NASA Astrophysics Data System (ADS)
Webb, Mathew A.; Hall, Andrew; Kidd, Darren; Minansy, Budiman
2016-05-01
Assessment of local spatial climatic variability is important in the planning of planting locations for horticultural crops. This study investigated three regression-based calibration methods (i.e. traditional versus two optimized methods) to relate short-term 12-month data series from 170 temperature loggers and 4 weather station sites with data series from nearby long-term Australian Bureau of Meteorology climate stations. The techniques trialled to interpolate climatic temperature variables, such as frost risk, growing degree days (GDDs) and chill hours, were regression kriging (RK), regression trees (RTs) and random forests (RFs). All three calibration methods produced accurate results, with the RK-based calibration method delivering the most accurate validation measures: coefficients of determination ( R 2) of 0.92, 0.97 and 0.95 and root-mean-square errors of 1.30, 0.80 and 1.31 °C, for daily minimum, daily maximum and hourly temperatures, respectively. Compared with the traditional method of calibration using direct linear regression between short-term and long-term stations, the RK-based calibration method improved R 2 and reduced root-mean-square error (RMSE) by at least 5 % and 0.47 °C for daily minimum temperature, 1 % and 0.23 °C for daily maximum temperature and 3 % and 0.33 °C for hourly temperature. Spatial modelling indicated insignificant differences between the interpolation methods, with the RK technique tending to be the slightly better method due to the high degree of spatial autocorrelation between logger sites.
Klose, T; Borchert, H-H; Pruss, A; Roth, W-K; Bohnen, H R; Putzker, M
2010-07-01
The German Armed Forces Blood Service in Koblenz supplies red blood cell concentrates (RBCs) to military and civilian institutions at home and to field hospitals during peacekeeping operations abroad. During long-distance transport, blood products can be exposed to extreme environmental conditions or inappropriate handling, which may compromise product quality. Different active and passive cooling systems, cooling elements, packaging material and data loggers were examined in a climate chamber. A number of techniques for measuring temperature were investigated in order to preserve the blood products' quality during transport, including some field tests with multiparametric data recording. Any kind of active cooling systems, conventional cooling elements and customary packaging material, as well as temperature-sensitive labels, minimum-maximum thermometers and intra-product measurement were found to be unsuitable for military requirement. The best results were obtained when the passively cooling RCB 25 transport box (Dometic) was used together with latent heat/cold storage elements (deltaT) and Junior data loggers (Escort). The elaborated protocol allows temperatures to be maintained between 2 and 6 degrees C as required by European guidelines for at least 36 h each and between 1 and 10 degrees C as required by German guidelines for at least 48 or 64 h at ambient temperatures between -10 and 40 degrees C. Preliminary results indicate that care must be taken concerning additional factors such as air pressure variation or vibration.
Measurements of duty cycle , the fraction of time the heating and cooling (HVAC) system was operating, were made in each participant's home during the spring season of the RTP Particulate Matter Panel Study. A miniature temperature sensor/data logger combination placed on the ...
Soil moisture and plant canopy temperature sensing for irrigation application in cotton
USDA-ARS?s Scientific Manuscript database
A wireless sensor network was deployed in a cotton field to monitor soil water status for irrigation. The network included two systems, a Decagon system and a microcontroller-based system. The Decagon system consists of soil volumetric water-content sensors, wireless data loggers, and a central data...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunter, Dan; Lee, Jason; Stoufer, Martin
2003-03-28
The NetLogger Toolkit is designed to monitor, under actual operating conditions, the behavior of all the elements of the application-to-application communication path in order to determine exactly where time is spent within a complex system Using NetLogger, distnbuted application components are modified to produce timestamped logs of "interesting" events at all the critical points of the distributed system Events from each component are correlated, which allov^ one to characterize the performance of all aspects of the system and network in detail. The NetLogger Toolkit itself consists of four components an API and library of functions to simplify the generation ofmore » application-level event logs, a set of tools for collecting and sorting log files, an event archive system, and a tool for visualization and analysis of the log files In order to instrument an application to produce event logs, the application developer inserts calls to the NetLogger API at all the critical points in the code, then links the application with the NetLogger library All the tools in the NetLogger Toolkit share a common log format, and assume the existence of accurate and synchronized system clocks NetLogger messages can be logged using an easy-to-read text based format based on the lETF-proposed ULM format, or a binary format that can still be used through the same API but that is several times faster and smaller, with performance comparable or better than binary message formats such as MPI, XDR, SDDF-Binary, and PBIO. The NetLogger binary format is both highly efficient and self-describing, thus optimized for the dynamic message construction and parsing of application instrumentation. NetLogger includes an "activation" API that allows NetLogger logging to be turned on, off, or modified by changing an external file This IS useful for activating logging in daemons/services (e g GndFTP server). The NetLogger reliability API provides the ability to specify backup logging locations and penodically try to reconnect broken TCP pipe. A typical use for this is to store data on local disk while net is down. An event archiver can log one or more incoming NetLogger streams to a local disk file (netlogd) or to a mySQL database (netarchd). We have found exploratory, visual analysis of the log event data to be the most useful means of determining the causes of performance anomalies The NetLogger Visualization tool, niv, has been developed to provide a flexible and interactive graphical representation of system-level and application-level events.« less
Vierling, Kerri T; Lorenz, Teresa J; Cunningham, Patrick; Potterf, Kelsi
2018-04-01
Tree cavities provide critical roosting and breeding sites for multiple species, and thermal environments in these cavities are important to understand. Our objectives were to (1) describe thermal characteristics in cavities between June 3 and August 9, 2014, and (2) investigate the environmental factors that influence cavity temperatures. We placed iButtons in 84 different cavities in ponderosa pine (Pinus ponderosa) forests in central Washington, and took hourly measurements for at least 8 days in each cavity. Temperatures above 40 °C are generally lethal to developing avian embryos, and ~ 18% of the cavities had internal temperatures of ≥ 40 °C for at least 1 h of each day. We modeled daily maximum cavity temperature, the amplitude of daily cavity temperatures, and the difference between the mean internal cavity and mean ambient temperatures as a function of several environmental variables. These variables included canopy cover, tree diameter at cavity height, cavity volume, entrance area, the hardness of the cavity body, the hardness of the cavity sill (which is the wood below the cavity entrance which forms the barrier between the cavity and the external environment), and sill width. Ambient temperature had the largest effect size for maximum cavity temperature and amplitude. Larger trees with harder sills may provide more thermally stable cavity environments, and decayed sills were positively associated with maximum cavity temperatures. Summer temperatures are projected to increase in this region, and additional research is needed to determine how the thermal environments of cavities will influence species occupancy, breeding, and survival.
NASA Astrophysics Data System (ADS)
Vierling, Kerri T.; Lorenz, Teresa J.; Cunningham, Patrick; Potterf, Kelsi
2017-11-01
Tree cavities provide critical roosting and breeding sites for multiple species, and thermal environments in these cavities are important to understand. Our objectives were to (1) describe thermal characteristics in cavities between June 3 and August 9, 2014, and (2) investigate the environmental factors that influence cavity temperatures. We placed iButtons in 84 different cavities in ponderosa pine (Pinus ponderosa) forests in central Washington, and took hourly measurements for at least 8 days in each cavity. Temperatures above 40 °C are generally lethal to developing avian embryos, and 18% of the cavities had internal temperatures of ≥ 40 °C for at least 1 h of each day. We modeled daily maximum cavity temperature, the amplitude of daily cavity temperatures, and the difference between the mean internal cavity and mean ambient temperatures as a function of several environmental variables. These variables included canopy cover, tree diameter at cavity height, cavity volume, entrance area, the hardness of the cavity body, the hardness of the cavity sill (which is the wood below the cavity entrance which forms the barrier between the cavity and the external environment), and sill width. Ambient temperature had the largest effect size for maximum cavity temperature and amplitude. Larger trees with harder sills may provide more thermally stable cavity environments, and decayed sills were positively associated with maximum cavity temperatures. Summer temperatures are projected to increase in this region, and additional research is needed to determine how the thermal environments of cavities will influence species occupancy, breeding, and survival.
Reuter, R R; Carroll, J A; Hulbert, L E; Dailey, J W; Galyean, M L
2010-10-01
A device was developed to monitor rectal temperature automatically in cattle for application in research settings. Compared with manual measurement of rectal temperature, this device decreases labor and time requirements and allows data collection without the influence of animal handling or restraint. The device consists of a custom-fabricated aluminum tail harness that supports an indwelling rectal temperature data logger. Materials cost approximately US $300 per unit, and units are completely reusable. Use of this device would increase the conditions under which accurate rectal temperature measurements can be obtained in experiments with cattle.
Ludynia, Katrin; Dehnhard, Nina; Poisbleau, Maud; Demongin, Laurent; Masello, Juan F.; Quillfeldt, Petra
2012-01-01
Logger technology has revolutionised our knowledge of the behaviour and physiology of free-living animals but handling and logger attachments may have negative effects on the behaviour of the animals and their welfare. We studied southern rockhopper penguin (Eudyptes chrysocome) females during the guard stage in three consecutive breeding seasons (2008/09−2010/11) to evaluate the effects of handling and logger attachment on foraging trip duration, dive behaviour and physiological parameters. Smaller dive loggers (TDRs) were used in 2010/11 for comparison to larger GPS data loggers used in all three seasons and we included two categories of control birds: handled controls and PIT control birds that were previously marked with passive integrative transponders (PITs), but which had not been handled during this study. Increased foraging trip duration was only observed in GPS birds during 2010/11, the breeding season in which we also found GPS birds foraging further away from the colony and travelling longer distances. Compared to previous breeding seasons, 2010/11 may have been a period with less favourable environmental conditions, which would enhance the impact of logger attachments. A comparison between GPS and TDR birds showed a significant difference in dive depth frequencies with birds carrying larger GPS data loggers diving shallower. Mean and maximum dive depths were similar between GPS and TDR birds. We measured little impact of logger attachments on physiological parameters (corticosterone, protein, triglyceride levels and leucocyte counts). Overall, handling and short-term logger attachments (1–3 days) showed limited impact on the behaviour and physiology of the birds but care must be taken with the size of data loggers on diving seabirds. Increased drag may alter their diving behaviour substantially, thus constraining them in their ability to catch prey. Results obtained in this study indicate that data recorded may also not represent their normal dive behaviour. PMID:23185623
Ground surface thermal regime of rock glaciers in the High Tatra Mts., Slovakia
NASA Astrophysics Data System (ADS)
Uxa, Tomáš; Mida, Peter
2017-04-01
Numerous lobate- or tongue-shaped debris accumulations, mostly interpreted as rock glaciers, have recently been recognized in the High Tatra Mts., Slovakia (49˚ 10' N, 20˚ 08' E). These prominent landforms arise due to creep of voluminous debris-ice mixtures, and as such they are excellent indicators of present or past permafrost existence. Hence rock glaciers are extensively utilized to model the distribution of permafrost in mountain areas. However, commonly applied rules of thumb may not be entirely indicative to discriminate particularly between the inactive (permafrost in disequilibrium with present climate) and relict (without permafrost) rock glaciers, which may substantially complicate permafrost modelling. Accordingly, the information about their thermal state is essential to calibrate and validate regional permafrost models. Limited ground temperature data have been, however, available from the High Tatra Mts. to date and therefore, we bring the updated and enhanced results from the thermal investigations of eleven rock glaciers located in the Slavkovská dolina and Veľká Studená dolina valleys at elevations between 1832 and 2090 m asl. Ground surface temperature (GST) has been continuously monitored at seven rock glaciers between October 2014 and September 2016 using nine Minikin Tie (EMS Brno Inc.) and iButton DS1922L (Maxim Integrated Inc.) loggers with an accuracy of ±0.2 and ±0.5 ˚ C, respectively. In addition, the bottom temperature of snow (BTS) was measured at 306 locations during spring of 2015 and 2016 to map potential permafrost occurrence within all the surveyed rock glaciers and in their immediate surroundings. Mean annual ground surface temperature (MAGST) of the rock glaciers ranged between -1.3 ˚ C and +2.6 ˚ C and averaged +1.0 ˚ C and +0.8 ˚ C in 2014-2015 and 2015-2016, respectively. Two sites continually showed negative MAGST and two other sites were below +0.5 ˚ C and +1.0 ˚ C, respectively. This strongly contrasts with mean annual air temperature (MAAT), which averaged +2.3 ˚ C in both years (estimated from nearby Lomnický štít station using a lapse rate of 6.5 ˚ C/km). Accordingly, GSTs showed negative surface offset (MAGST-MAAT) of -1.3 ˚ C and -1.5 ˚ C in 2014-2015 and 2015-2016, respectively. At the coldest sites, the surface offset regularly reached values well below -2 ˚ C and dropped up to -3.3 ˚ C. GSTs recorded prior to the onset of snow melting (i.e. BTS) averaged -3.8 ˚ C and -3.2 ˚ C in spring of 2015 and 2016, respectively, and varied between -5.8 ˚ C and -1.6 ˚ C. One-time BTS values showed the average of -2.8 ˚ C, but relatively high short-distance heterogeneity of BTS values, ranging between -8.3 ˚ C and 0.0 ˚ C, was encountered across the rock-glacier surfaces. The results suggest that permafrost occurrence is probable or possible in a total of ten rock glaciers, while its absence is probable only in one of the investigated landforms. We classify the latter form as relict and other two rock glaciers are suggested to be in inactive/relict state. Six rock glaciers are believed to be inactive and two even active/inactive. In most cases, however, permafrost likely occurs in a form of isolated patches or discontinuously and presumably degrades under present climate conditions.
The design of a microprocessor-based data logger
Leap, K.J.; Dedini, L.A.
1982-01-01
The design of a microprocessor-based data logger, which collects and digitizes analog voltage signals from a continuous-measuring instrumentation system and transmits serial data to a magnetic tape recorder, is discussed. The data logger was assembled from commercially-available components and can be user-programmed for greater flexibility. A description of the data logger hardware and software designs, general operating instructions, the microprocessor program listing, and electrical schematic diagrams are presented.
Data-Logger Interface And Test Controller
NASA Technical Reports Server (NTRS)
Burch, Donnie R.
1995-01-01
Data-logger interface and test controller developed to enable automation of tests in conjunction with data-acquisition functions performed by data loggers that have output-switching capabilities. Includes relay logic circuits that remain deenergized until out-of-tolerance condition on any data channel discovered. Designed to be connected to Fluke model 2286A (or equivalent) data-logger system, which features 3 control channels with 6 data inputs per channel. Includes elapsed-time counter that keeps track of power outages.
Schultz, Luke; Heck, Michael; Hockman-Wert, David; Allai, T; Wengerd, Seth J.; Cook, NA; Dunham, Jason B.
2017-01-01
We studied how drought and an associated stressor, wildfire, influenced stream flow permanence and thermal regimes in a Great Basin stream network. We quantified these responses by collecting information with a spatially extensive network of data loggers. To understand the effects of wildfire specifically, we used data from 4 additional sites that were installed prior to a 2012 fire that burned nearly the entire watershed. Within the sampled network 73 reaches were classified as perennial, yet only 51 contained surface water during logger installation in 2014. Among the sites with pre-fire temperature data, we observed 2–4 °C increases in maximum daily stream temperature relative to an unburned control in the month following the fire; effects (elevated up to 6.6 °C) appeared to persist for at least one year. When observed August mean temperatures in 2015 (the peak of regionally severe drought) were compared to those predicted by a regional stream temperature model, we observed deviations of −2.1°-3.5°. The model under-predicted and over-predicted August mean by > 1 °C in 54% and 10% of sites, respectively, and deviance from predicted was negatively associated with elevation. Combined drought and post-fire conditions appeared to greatly restrict thermally-suitable habitat for Lahontan cutthroat trout (Oncorhynchus clarkii henshawi).
Encourage student learning of hydraulic matters by the use of Arduino platform
NASA Astrophysics Data System (ADS)
Rodriguez Sinobas, Leonor; Granja García, Javier; Sánchez Calvo, Raúl
2014-05-01
Arduino is an open-source electronics prototyping platform based on flexible, easy-to-use hardware and software. It's intended for several purposes to anyone interested in creating interactive objects or environments. The hydraulic matters teach at the Agricultural Engineering School at the Technical University of Madrid deal with practical issues regarding the measurement of variables such as pressure, discharge, temperature and soil water content. Most of the data loggers available in the market for these variables at expensive and not always affordable. On the other hand, current students are eager to manage new technological devices thus, their skills could be oriented not only to the application of an electronic platform as Arduino to build low cost data loggers for different purposes, but to encourage their learning in the hydraulic matters improving their self esteem
George, Scott D.; Baldigo, Barry P.; Smith, Martyn J.; Mckeown, Donald M; Faulringer, Jason
2016-01-01
Water temperature is a key component of aquatic ecosystems because it plays a pivotal role in determining the suitability of stream and river habitat to most freshwater fish species. Continuous temperature loggers and airborne thermal infrared (TIR) remote sensing were used to assess temporal and spatial temperature patterns on the Upper Schoharie Creek and West Kill in the Catskill Mountains, New York, USA. Specific objectives were to characterize (1) contemporary thermal conditions, (2) temporal and spatial variations in stressful water temperatures, and (3) the availability of thermal refuges. In-stream loggers collected data from October 2010 to October 2012 and showed summer water temperatures exceeded the 1-day and 7-day thermal tolerance limits for trout survival at five of the seven study sites during both summers. Results of the 7 August 2012 TIR indicated there was little thermal refuge at the time of the flight. About 690,170 m2 of water surface area were mapped on the Upper Schoharie, yet only 0.009% (59 m2) was more than 1.0 °C below the median water surface temperature (BMT) at the thalweg and no areas were more than 2.0 °C BMT. On the West Kill, 79,098 m2 were mapped and 0.085% (67 m2) and 0.018% (14 m2) were BMT by 1 and 2 °C, respectively. These results indicate that summer temperatures in the majority of the study area are stressful for trout and may adversely affect growth and survival. Validation studies are needed to confirm the expectation that resident trout are in poor condition or absent from the downstream portion of the study area during warm-water periods.
Controlling sediment collection with data loggers
Rand E. Eads
1991-01-01
Abstract - The proliferation of commercial non-programmable data loggers in the past five years has done little to increase sediment sampling efficiency in remote locations. Recent advances in microelectronics have encouraged the development of commercial, low-power, programmable data loggers at reasonable cost. Although some facets of hydrologic data collection may...
Assessing safety awareness and knowledge and behavioral change among West Virginia loggers
Helmkamp, J; Bell, J; Lundstrom, W; Ramprasad, J; Haque, A
2004-01-01
Objective: To determine if a video used during logger training influences safety attitude, knowledge, and workplace habits. Method: From April 2002 to October 2003, loggers receiving training through the West Virginia Division of Forestry were given a new safety module. This consisted of a pre-training survey, viewing video, brief introduction to field safety guide, and an immediate post-training survey. Six months after training, loggers were contacted by telephone to assess workplace behavioral changes. Results: 1197 loggers attended 80 training sessions and completed surveys; 21% were contacted at follow up. Pre-training surveys indicated that half said "accidents" were part of the job and had experienced a "close call" in their work. An overwhelming majority felt that safety management and periodic meetings were important. Over 75% indicated they would not take risks in order to make a profit. Several statistically significant improvements were noted in safety knowledge after viewing the video: logger's location in relation to the tree stump during fatal incidents and the pictorial identification of an overloaded truck and the safest cutting notch. At follow up, many of the loggers said they related to the real life victim stories portrayed in the video. Further, the field guide served as a quick and easy reference and taught them valuable tips on safe cutting and felling. Conclusions: Significant changes in safety knowledge and attitude among certified loggers resulted from viewing the video during training. Subsequent use of the video and field guide at the worksite encouraged positive change in self reported work habits and practices. PMID:15314051
The Gem Infrasound Logger and Custom-Built Instrumentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Jacob F.; Johnson, Jeffrey B.; Bowman, Daniel C.
Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensorsmore » and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.« less
The Gem Infrasound Logger and Custom-Built Instrumentation
Anderson, Jacob F.; Johnson, Jeffrey B.; Bowman, Daniel C.; ...
2017-11-22
Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensorsmore » and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.« less
Spatial and temporal variability of canopy microclimate in a Sierra Nevada riparian forest
T. Rambo; M. North
2008-01-01
Past riparian microclimate studies have measured changes horizontally from streams, but not vertically through the forest canopy. We recorded temperature and relative humidity for a year along a two-dimensional grid of 24 data-loggers arrayed up to 40 m height in four trees 2 - 30 m slope distance from a perennial second order stream in...
Operating manual for the RRL 8 channel data logger
NASA Technical Reports Server (NTRS)
Paluch, E. J.; Shelton, J. D.; Gardner, C. S.
1979-01-01
A data collection device which takes measurements from external sensors at user specified time intervals is described. Three sensor ports are dedicated to temperature, air pressure, and dew point. Five general purpose sensor ports are provided. The user specifies when the measurements are recorded as well as when the information is read or stored in a minicomputer or a paper tape.
Morley, Simon A; Martin, Stephanie M; Day, Robert W; Ericson, Jess; Lai, Chien-Houng; Lamare, Miles; Tan, Koh-Siang; Thorne, Michael A S; Peck, Lloyd S
2012-01-01
The thermal reaction norms of 4 closely related intertidal Nacellid limpets, Antarctic (Nacella concinna), New Zealand (Cellana ornata), Australia (C. tramoserica) and Singapore (C. radiata), were compared across environments with different temperature magnitude, variability and predictability, to test their relative vulnerability to different scales of climate warming. Lethal limits were measured alongside a newly developed metric of "duration tenacity", which was tested at different temperatures to calculate the thermal reaction norm of limpet adductor muscle fatigue. Except in C. tramoserica which had a wide optimum range with two break points, duration tenacity did not follow a typical aerobic capacity curve but was best described by a single break point at an optimum temperature. Thermal reaction norms were shifted to warmer temperatures in warmer environments; the optimum temperature for tenacity (T(opt)) increased from 1.0°C (N. concinna) to 14.3°C (C. ornata) to 18.0°C (an average for the optimum range of C. tramoserica) to 27.6°C (C. radiata). The temperature limits for duration tenacity of the 4 species were most consistently correlated with both maximum sea surface temperature and summer maximum in situ habitat logger temperature. Tropical C. radiata, which lives in the least variable and most predictable environment, generally had the lowest warming tolerance and thermal safety margin (WT and TSM; respectively the thermal buffer of CT(max) and T(opt) over habitat temperature). However, the two temperate species, C. ornata and C. tramoserica, which live in a variable and seasonally unpredictable microhabitat, had the lowest TSM relative to in situ logger temperature. N. concinna which lives in the most variable, but seasonally predictable microhabitat, generally had the highest TSMs. Intertidal animals live at the highly variable interface between terrestrial and marine biomes and even small changes in the magnitude and predictability of their environment could markedly influence their future distributions.
Morley, Simon A.; Martin, Stephanie M.; Day, Robert W.; Ericson, Jess; Lai, Chien-Houng; Lamare, Miles; Tan, Koh-Siang; Thorne, Michael A. S.; Peck, Lloyd S.
2012-01-01
The thermal reaction norms of 4 closely related intertidal Nacellid limpets, Antarctic (Nacella concinna), New Zealand (Cellana ornata), Australia (C. tramoserica) and Singapore (C. radiata), were compared across environments with different temperature magnitude, variability and predictability, to test their relative vulnerability to different scales of climate warming. Lethal limits were measured alongside a newly developed metric of “duration tenacity”, which was tested at different temperatures to calculate the thermal reaction norm of limpet adductor muscle fatigue. Except in C. tramoserica which had a wide optimum range with two break points, duration tenacity did not follow a typical aerobic capacity curve but was best described by a single break point at an optimum temperature. Thermal reaction norms were shifted to warmer temperatures in warmer environments; the optimum temperature for tenacity (Topt) increased from 1.0°C (N. concinna) to 14.3°C (C. ornata) to 18.0°C (an average for the optimum range of C. tramoserica) to 27.6°C (C. radiata). The temperature limits for duration tenacity of the 4 species were most consistently correlated with both maximum sea surface temperature and summer maximum in situ habitat logger temperature. Tropical C. radiata, which lives in the least variable and most predictable environment, generally had the lowest warming tolerance and thermal safety margin (WT and TSM; respectively the thermal buffer of CTmax and Topt over habitat temperature). However, the two temperate species, C. ornata and C. tramoserica, which live in a variable and seasonally unpredictable microhabitat, had the lowest TSM relative to in situ logger temperature. N. concinna which lives in the most variable, but seasonally predictable microhabitat, generally had the highest TSMs. Intertidal animals live at the highly variable interface between terrestrial and marine biomes and even small changes in the magnitude and predictability of their environment could markedly influence their future distributions. PMID:23285194
NASA Astrophysics Data System (ADS)
Scotch, C.; Murgulet, D.; Hay, R.
2012-12-01
This study utilizes a multidisciplinary approach to better analyze the extent to which groundwater and surface water interact in the Oso Creek water shed of South Texas using temperature data, electrical resistivity and numerical modeling methods. The three primary objectives of this study are to: (1) identify primary areas of streambed groundwater-surface water interaction using temperature time series and resistivity soundings; (2) improve understanding of solute flow and groundwater, surface water, and sediment interaction in a semiarid, urban coastal area; (3) improve our understanding of groundwater contribution to contaminant transport and discharge to the bays and estuaries and ultimately the Gulf of Mexico. Temperature data was acquired over a one year period, using temperature loggers, from June 11, 2009 to May 18, 2010 at 15-minute intervals from 17 monitoring sites along Oso Creek and its tributaries. Each monitoring site consisted of 4 temperature loggers equally vertically spaced from the stream surface down to a depth of one meter. Furthermore, groundwater temperatures and water levels were collected from wells adjacent to the temperature monitoring sites. In order to fulfill the objectives of this study, existing hydrogeologic, stratigraphic, and other ancillary data are being integrated into a finite difference model developed using the USGS VS2DT software for the Oso Creek Watershed. The model will be calibrated using existing temperature and water level data and a resistivity component will also be added to assure accuracy of the model and temperature data by helping to identify varying lithologies and water conductivities. Compiling a time-series of temperature data and incorporating available hydrostratigraphic, geomorphologic and water level data will enable the development of a comprehensive database. This database is necessary to develop the detailed flow model that will enable an understanding of the extent of groundwater surface water interaction and their associated flow regimes.
A Data-Based Console Logger for Mission Operations Team Coordination
NASA Technical Reports Server (NTRS)
Thronesbery, Carroll; Malin, Jane T.; Jenks, Kenneth; Overland, David; Oliver, Patrick; Zhang, Jiajie; Gong, Yang; Zhang, Tao
2005-01-01
Concepts and prototypes1,2 are discussed for a data-based console logger (D-Logger) to meet new challenges for coordination among flight controllers arising from new exploration mission concepts. The challenges include communication delays, increased crew autonomy, multiple concurrent missions, reduced-size flight support teams that include multidisciplinary flight controllers during quiescent periods, and migrating some flight support activities to flight controller offices. A spiral development approach has been adopted, making simple, but useful functions available early and adding more extensive support later. Evaluations have guided the development of the D-Logger from the beginning and continue to provide valuable user influence about upcoming requirements. D-Logger is part of a suite of tools designed to support future operations personnel and crew. While these tools can be used independently, when used together, they provide yet another level of support by interacting with one another. Recommendations are offered for the development of similar projects.
New York Urban Hydro-Meteorological Testbed (NY-uHMT)
NASA Astrophysics Data System (ADS)
Norouzi, H.; Bah, A.
2017-12-01
It is well known that heat waves kill more persons, on average, than any other extreme weather event in the United States. New York City experiences much adversity due to inclement weather. Exploring climate variation in New Yorker City will help scientists and local government to detect and forecast extreme weather hazards and gather more localized temperature data within the five boroughs. Ground based weather stations are widely used to provide real time data to the public to prevent disasters. The New York urban Hydro-meteorological Testbed (NY-uHMT) is a hydro meteorological network that is used to investigate climate change in the New York City area. It is composed of twenty autonomous weather stations that will gather information on air temperature, relative humidity, rainfall and soil moisture properties around the densely populated NYC area. For each station, the data is stored on a Campbell Scientific CR200x data logger and can be accessed remotely using the LoggerNet software, or by direct connection using an RS-232 cable. Real-time weather data is acquired every fifteen minutes. The data is then periodically sampled and graphed through MATLAB code to be broadcasted on the uHMT website and is available at no charge to the public. We anticipate the results will show that the temperature, humidity, precipitation and soil moisture will vary from location to location depending on the magnitude of urbanization to the area.
BOREAS TE-6 1994 Soil and Air Temperatures in the NSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Curd, Shelaine (Editor); Norman, John; Wilson, Tim
2000-01-01
The BOREAS TE-6 team collected several data sets to examine the influence of vegetation, climate, and their interactions on the major carbon fluxes for boreal forest species. This data set contains measurements of the air temperature at a single height and soil temperature at several depths in the NSA from 25-May to 08-Oct- 1994. Chromel-Constantan thermocouple wires run by a miniprogrammable data logger (Model 21X, Campbell Scientific, Inc., Logan, UT) provided direct measurements of temperature. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distrobuted Activity Archive Center (DAAC).
Yanshu Li; Daowei Zhang
2010-01-01
A framework was developed to estimate the welfare incidence of the 1996 U.S.-Canada Softwood Lumber Agreement among producers in two-processing-stage markets--timberland owners, loggers, and lumber manufacturers--in the U.S. South. Timberland owners are the largest beneficiary whereas lumber manufacturers are the second and loggers the least. Empirically, without...
Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers
Lee, Y.; Bok, J. D.; Lee, H. J.; Lee, H. G.; Kim, D.; Lee, I.; Kang, S. K.; Choi, Y. J.
2016-01-01
Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean±standard deviation [SD], 37.1°C to 37.36°C±0.91°C to 1.02°C). STs are 1.39°C to 1.65°C lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below 36.5°C or 37°C, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below 36.5°C or 37°C resulting in a much improved mean±SD of 37.6°C±0.64°C or 37.8°C±0.55°C, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck. PMID:26732455
A simple method for in situ monitoring of water temperature in substrates used by spawning salmonids
Zimmerman, Christian E.; Finn, James E.
2012-01-01
Interstitial water temperature within spawning habitats of salmonids may differ from surface-water temperature depending on intragravel flow paths, geomorphic setting, or presence of groundwater. Because survival and developmental timing of salmon are partly controlled by temperature, monitoring temperature within gravels used by spawning salmonids is required to adequately describe the environment experienced by incubating eggs and embryos. Here we describe a simple method of deploying electronic data loggers within gravel substrates with minimal alteration of the natural gravel structure and composition. Using data collected in spawning sites used by summer and fall chum salmon Oncorhynchus keta from two streams within the Yukon River watershed, we compare contrasting thermal regimes to demonstrate the utility of this method.
Teaching Science with Technology
NASA Astrophysics Data System (ADS)
Gornostaeva, Svetlana
2015-04-01
This is a short introduction about me, description of different teaching methods, which is used in my teaching practice of Geography, biology and GIS systems education. The main part is tell about practical lesson with lab Vernier. My name is Svetlana Gornostaeva. I am a geography, biology and GIS systems teacher in Tallinn Mustjõe Gymnasium (www.mjg.ee) and private school Garant (http://www.erakoolgarant.ee/). In my teaching practice I do all to show that science courses are very important, interesting, and do not difficult. I use differentiated instruction methods also consider individual needs. At lessons is used different active teaching methods such as individual work of various levels of difficulty, team works, creative tasks, interactive exercises, excursions, role-playing games, meeting with experts. On my lessons I use visual aids (maps, a collection of rocks and minerals, herbarium, posters, Vernier data logger). My favorite teaching methods are excursions, meeting with experts and practical lesson with lab Vernier. A small part of my job demonstrate my poster. In the next abstract I want to bring a one practical work with Vernier which I do with my students, when we teach a theme "Atmosphere and climate". OUTDOOR LEARNING. SUBJECT "ATMOSPHERE AND CLIMATE". WEATHER OBSERVATIONS WITH VERNIER DATA LOGGER. The aim: students teach to use Vernier data logger and measure climatic parameters such as: temperature, humidity, atmospheric pressure, solar radiation, ultraviolet light radiation, wind speed. In working process pupils also teach work together, observe natural processes, analyze. Children are working by small groups, 4-5 in each group. Every one should personally measure all parameters and put numbers into the table. After it group observe cloudiness, analyze table and give conclusion "Is at this moment dominates cyclone or anticyclone ?". Children really like this kind of job. Vernier data logger it is really fantastic tool. It is mobile lab. This system give possibilities to easy and fast observe nature process in dynamic. Vernier puts easy-to-use data loggers, sensors, experiments and graphing/analysis software into the hands of students, helping educators develop the next generation of scientists and engineers. You also can do a bit fun with Vernier. For instance, children, who finished their job faster with anemometer can give answer to the question : whom lungs are bigger?" or with thermometer give answer to the question : who has the hottest hands?". Also with thermometer children can draw a rabbit or a mountain. I convinced that Vernier data logger with sensors should be in each school. SUMMARY Personally I am young teacher and do not have a lot of work experience, but I really like my work and do all to share my skills to my students.
Worldwide Research, Worldwide Participation: Web-Based Test Logger
NASA Technical Reports Server (NTRS)
Clark, David A.
1998-01-01
Thanks to the World Wide Web, a new paradigm has been born. ESCORT (steady state data system) facilities can now be configured to use a Web-based test logger, enabling worldwide participation in tests. NASA Lewis Research Center's new Web-based test logger for ESCORT automatically writes selected test and facility parameters to a browser and allows researchers to insert comments. All data can be viewed in real time via Internet connections, so anyone with a Web browser and the correct URL (universal resource locator, or Web address) can interactively participate. As the test proceeds and ESCORT data are taken, Web browsers connected to the logger are updated automatically. The use of this logger has demonstrated several benefits. First, researchers are free from manual data entry and are able to focus more on the tests. Second, research logs can be printed in report format immediately after (or during) a test. And finally, all test information is readily available to an international public.
A Custom Data Logger for Real-Time Remote Field Data Collections
2017-03-01
ERDC/CHL CHETN-VI-46 March 2017 Approved for public release; distribution is unlimited. A Custom Data Logger for Real- Time Remote Field Data...Field Research Facility (FRF), for remote real- time data collections. This custom data logger is compact and energy efficient but has the same...INTRODUCTION: Real- time data collections offer many advantages: 1. Instrument failures can be rapidly detected and repaired, thereby minimizing
Progress on Component Evaluation for Nuclear Explosion Monitoring
2008-09-01
one data logger, Geotech Smart24. For the infrasound sensors tested, the test results allow us to conclude that both sensors had sufficiently quiet...a lower frequency than expected. Sandia was also asked to evaluate the Geotech Smart24 data logger for qualification as a replacement to the Geotech ...results of using 26-bit quantization. Characterization Geotech Smart24 Data-Logger with Active Fortezza Crypto Card Data Signing Over the spring
Increase of child car seat temperature in cars parked in the outpatient parking lot.
Sugimura, Tetsu; Suzue, Junji; Kamada, Makoto; Ozaki, Yukiko; Tananari, Yoshifumi; Maeno, Yasuki; Ito, Shinichi; Nishino, Hiroshi; Kakimoto, Noriko; Yamakawa, Rumi
2011-12-01
A guideline for the safe use of child car seats (CS) was published by the Japan Pediatric Society in 2008. There have been few studies of the increase of temperature of a CS in parked cars. The aim of this study was to determine the change in the temperature of the CS in cars parked in full sun. The temperature of CS was measured during summer (July and August) in 2006, 2007, and 2008. The CS used in this study (n= 50) were for children (≤ 6 years old) who were taken by car to Sugimura Children's Medical Clinic. Temperatures were only measured on sunny days. Measurements were performed from 09.00 to 17.00 hours. Thermochron (Thermochron i-Button: G type, Maxim Integrated Products, CA, USA) was used to measure the temperatures. The maximum temperatures of CS were compared in time at the clinic, taking into consideration seat colors, and car colors. Of the 50 cars, three cars were excluded due to being in the shade while the temperature was measured. A total of 47 cars were used for this study. The temperature of the CS ranged from 38.0 to 65.5°C (47.8 ± 5.8°C). Eighteen CS (38.3%) reached a temperature of 50°C or above. The maximum temperature of the 13.00-15.00-hours group was significantly higher than that of the 09.00-11.00-hours group (P= 0.035). The CS temperatures in the black car group were significantly higher than those of the white car group (P= 0.013). CS may become very hot while a car is parked in sun, especially if the car and the CS are black, so the CS should be cooled before a young child is placed in it. Guardians of small children should be aware of this risk. © 2011 The Authors. Pediatrics International © 2011 Japan Pediatric Society.
Arismendi, Ivan; Dunham, Jason B.; Heck, Michael; Schultz, Luke; Hockman-Wert, David
2017-01-01
Intermittent and ephemeral streams represent more than half of the length of the global river network. Dryland freshwater ecosystems are especially vulnerable to changes in human-related water uses as well as shifts in terrestrial climates. Yet, the description and quantification of patterns of flow permanence in these systems is challenging mostly due to difficulties in instrumentation. Here, we took advantage of existing stream temperature datasets in dryland streams in the northwest Great Basin desert, USA, to extract critical information on climate-sensitive patterns of flow permanence. We used a signal detection technique, Hidden Markov Models (HMMs), to extract information from daily time series of stream temperature to diagnose patterns of stream drying. Specifically, we applied HMMs to time series of daily standard deviation (SD) of stream temperature (i.e., dry stream channels typically display highly variable daily temperature records compared to wet stream channels) between April and August (2015–2016). We used information from paired stream and air temperature data loggers as well as co-located stream temperature data loggers with electrical resistors as confirmatory sources of the timing of stream drying. We expanded our approach to an entire stream network to illustrate the utility of the method to detect patterns of flow permanence over a broader spatial extent. We successfully identified and separated signals characteristic of wet and dry stream conditions and their shifts over time. Most of our study sites within the entire stream network exhibited a single state over the entire season (80%), but a portion of them showed one or more shifts among states (17%). We provide recommendations to use this approach based on a series of simple steps. Our findings illustrate a successful method that can be used to rigorously quantify flow permanence regimes in streams using existing records of stream temperature.
NASA Astrophysics Data System (ADS)
Salvador-Franch, Ferran; Salvà-Catarineu, Montserrat; Oliva, Marc; Gómez-Ortiz, Antonio
2016-04-01
Glaciers shaped the headwaters and valley floors in the Eastern Pyrenees during the Last Glaciation at elevations above 2100-2200 m. Since the deglaciation of these areas, periglacial processes have generated a wide range of periglacial landforms, such as rock glaciers, patterned ground and debris slopes. The role of soil temperatures is decisive for the degree of activity of periglacial processes: cryoturbation, solifluction, frost weathering, etc. Nowadays, periglacial processes in the Eastern Pyrenees are driven by a seasonal frozen layer extending 5-7 months. In general, at 2100 m the seasonal frost reaches 20 cm depth, while at 2700 m reaches 50 cm depth. However, soil temperatures, and thus, periglacial processes are strongly controlled by the large interannual variability of the snow cover. With the purpose of understanding the rhythm and intensity of soil freezing/thawing in 2003 we set up several monitoring sites along a vertical transect from the valley floors (1100 m) to the high plateaus (2700 m) across the southern slope of the Puigpedrós massif (2914 m), in the Eastern Pyrenees. The monitoring of soil temperatures has been conducted from 2003 to 2015 in different periglacial landforms using UTL and Hobo loggers. These loggers were installed at depths of 5, 20 and 50 cm at five sites: Calmquerdós (2730 m), Malniu (2230 m), La Feixa (2150 m), Meranges (1600 m) and Das (1097 m). Air temperatures used as reference come from two automatic stations of the Catalan Meteorological Survey in Malniu and Das, and with two loggers installed in La Feixa and Meranges. No permafrost regime was detected in none of the sites. Data shows evidence of the control of snow cover on the depth of the frozen layer and on the number of freeze-thaw cycles. Air temperatures at 2000-2200 m show a mean of 150 freeze-thaw cycles per year. In La Feixa, with very thin snow cover, only 67 cycles are recorded at 5 cm depth and 5 cycles at 50 cm depth. In Malniu, located at a higher elevation showing a thicker and longer snow cover, only 17 freeze-thaw cycles per year are recorded at 5 cm depth, with no cycles recorded at 50 cm depth. Soils remain unfrozen during years with a very thick snow cover. The snow cover is also largely conditioned by the microtopography and exposure to the dominant winds. These factors condition the distribution, duration and intensity of the frozen ground and, thus, determine the intensity of periglacial processes in these areas.
NASA Astrophysics Data System (ADS)
Salvador-Franch, Ferran; Salvà-Catarineu, Montserrat; Oliva, Marc; Gómez-Ortiz, Antonio
2015-04-01
During the Last Glaciation glaciers shaped the headwaters and valley floors in the Eastern Pyrenees above 2100-2200 m. Since the deglaciation of these high mountain environments, periglacial processes have generated rock glaciers, patterned ground and debris slopes. The role of soil temperatures is decisive regarding the contemporary activity of several processes: cryoturbation, solifluction, frost weathering, etc. Nowadays, periglacial processes are driven by a seasonal frozen layer extending 4-5 months. At 2100 m the seasonal frost reaches 20 cm depth, while at 2700 m reaches 50 cm depth. However, soil temperatures, and thus, periglacial processes are strongly controlled by the large interannual variability of the snow cover. With the purpose of understanding the rhythm and intensity of soil freezing/thawing we have set up several monitoring sites along a vertical transect from the high plateaus (2700 m) to the valley floors (1100 m) across the southern slope of the Puigpedrós massif (2914 m), in the Eastern Pyrenees. The monitoring of soil temperatures extends from 2003 to 2014. TinyTalk, UTL and Hobo loggers have been used in this study. These loggers were installed at depths of -5, -20 and -50 cm at five sites: Calmquerdós (2730 m), Malniu (2230 m), La Feixa (2150 m), Meranges (1600 m) and Das (1097 m). Air temperatures used as reference come from two automatic stations of the Catalan Meteorological Survey (Malniu, Das) as well as from two loggers installed in La Feixa and Meranges. Data shows the control of snow cover on the depth of the frozen layer and on the number of freeze-thaw cycles. Air temperatures at 2000-2200 m show a mean of 150 freeze-thaw cycles per year. In La Feixa, with very thin snow cover, only 67 cycles are recorded at 5 cm depth and 5 cycles at 50 cm depth. In Malniu, located at a higher elevation showing a thicker and longer snow cover, only 17 freeze-thaw cycles per year are recorded at 5 cm depth, with no cycles recorded at 50 cm depth. Soils remain unfrozen during years with a very thick snow cover. The snow cover is also largely conditioned by the microtopography and exposure to the dominant winds. These factors condition the distribution, duration and intensity of the frozen ground and, thus, determine the intensity of periglacial processes in these areas.
López-Luna, Marco A; Hidalgo-Mihart, Mircea G; Aguirre-León, Gustavo; González-Ramón, Mariana Del C; Rangel-Mendoza, Judith A
2015-01-01
Incubation temperature is an important aspect in terms of biological performance among crocodiles, and several controlled experiments have demonstrated a significant relationship between incubation temperature, success in hatching and survival of hatchlings. However, a few studies have tested these relationships in the wild. The objective of this study was to determine the relationship of nest characteristics and environment (hatch year, nest basal area and height, clutch size, distance to shore line, and vegetation cover), to incubation temperature and hatching success among Morelet's crocodile (Crocodylus moreletii). The study was carried out during the nesting seasons of Morelet's crocodile, from 2007 to 2009 in the Laguna de Las Ilusiones, an urban lake located in Villahermosa, Tabasco, Mexico. We physically characterized 18 nests and inserted a temperature data logger in each nest chamber. At the end of the nesting season and prior to hatching, we recovered the crocodile eggs and data loggers and calculated hatching success, under laboratory conditions. We related the environmental variables of the nest with the mean and fluctuation (standard deviation) of nest temperature, using linear models. We also related the environmental variables affecting the nest, to mean nest temperature and fluctuation in incubation temperature and to hatching success, using linear models. Although we found differences in incubation temperature between nests, mean incubation temperature did not differ between years, but there were differences in nest thermal fluctuation between years. The mean incubation temperature for 11 nests (61.1%) was lower than the suggested Female-Male pivotal temperature (producing 50% of each sex) for this species, and all hatchlings obtained were males. There were no differences in clutch size between years, but hatching success varied. Our study indicates that hatching success depends on certain environmental variables and nest conditions to which the eggs are subjected, including season, nest size and clutch size. We also discuss the importance of the fluctuation of incubation temperature on hatching success and sex determination. Copyright © 2015 Elsevier Ltd. All rights reserved.
High-Altitude Hydration System
NASA Technical Reports Server (NTRS)
Parazynski, Scott E.; Orndoff, Evelyne; Bue, Grant C.; Schaefbauer, Mark E.; Urban, Kase
2010-01-01
Three methods are being developed for keeping water from freezing during high-altitude climbs so that mountaineers can remain hydrated. Three strategies have been developed. At the time of this reporting two needed to be tested in the field and one was conceptual. The first method is Passive Thermal Control Using Aerogels. This involves mounting the fluid reservoir of the climber s canteen to an inner layer of clothing for better heat retention. For the field test, bottles were mounted to the inner fleece layer of clothing, and then aerogel insulation was placed on the outside of the bottle, and circumferentially around the drink straw. When climbers need to drink, they can pull up the insulated straw from underneath the down suit, take a sip, and then put it back into the relative warmth of the suit. For the field test, a data logger assessed the temperatures of the water reservoir, as well as near the tip of the drink straw. The second method is Passive Thermal Control with Copper-Shielded Drink Straw and Aerogels, also mounted to inner layers of clothing for better heat retention. Braided wire emanates from the inside of the fleece jacket layer, and continues up and around the drink straw in order to use body heat to keep the system-critical drink straw warm enough to keep water in the liquid state. For the field test, a data logger will be used to compare this with the above concept. The third, and still conceptual, method is Active Thermal Control with Microcontroller. If the above methods do not work, microcontrollers and tape heaters have been identified that could keep the drink straw warm even under extremely cold conditions. Power requirements are not yet determined because the thermal environment inside the down suit relative to the external environment has not been established. A data logger will be used to track both the external and internal temperatures of the suit on a summit day.
Uetera, Yushi; Shigematsu, Hiroshi; Baba, Zenzou; Kumada, Naohito; Kawamura, Kunio
2003-01-01
Recently, the wireless thermologger system was developed. It consists of a wireless logger and the attached computer system. The wireless logger has a wireless structure and can be placed anywhere in the sterilizer chamber for thermometry. In the present study, thermal evaluations were performed twice using the wireless thermologger system in the sterilizer chamber of the prevacuum autoclave unequipped with sensor ports when it failed to pass the Bowie-Dick test and underwent mechanical repairs. Thermometry was performed when the Bowie-Dick test cycle was operated. The heat up time was measured in the range of 120.0-134.0 degrees C. The F0 value was calculated with the reference temperature at 121.0 degrees C and Z value at 10 degrees C when the sterilization temperature was over 120.0 degrees C. The first thermal evaluation was performed after three air-leaking points were repaired along with the replacement of the vacuum pump and the thermosensor. It revealed that the heat-up time was 4 min and 42 s and the F0 value was 137.5. After the temperature control systems were adjusted using the process calibrator in the prevacuum autoclave, the second thermal evaluation revealed that the heat up time was 2 mins 1 s and the F0 value was 102.7. The present study suggests that the wireless thermologger system is useful in the management of the autoclave unequipped with sensor ports when it undergoes mechanical repairs.
Inexpensive, Low Power, Open-Source Data Logging hardware development
NASA Astrophysics Data System (ADS)
Sandell, C. T.; Schulz, B.; Wickert, A. D.
2017-12-01
Over the past six years, we have developed a suite of open-source, low-cost, and lightweight data loggers for scientific research. These loggers employ the popular and easy-to-use Arduino programming environment, but consist of custom hardware optimized for field research. They may be connected to a broad and expanding range of off-the-shelf sensors, with software support built in directly to the "ALog" library. Three main models exist: The ALog (for Autonomous or Arduino Logger) is the extreme low-power model for years-long deployments with only primary AA or D batteries. The ALog shield is a stripped-down ALog that nests with a standard Arduino board for prototyping or education. The TLog (for Telemetering Logger) contains an embedded radio with 500 m range and a GPS for communications and precision timekeeping. This enables meshed networks of loggers that can send their data back to an internet-connected "home base" logger for near-real-time field data retrieval. All boards feature feature a high-precision clock, full size SD card slot for high-volume data storage, large screw terminals to connect sensors, interrupts, SPI and I2C communication capability, and 3.3V/5V power outputs. The ALog and TLog have fourteen 16-bit analog inputs with a precision voltage reference for precise analog measurements. Their components are rated -40 to +85 degrees C, and they have been tested in harsh field conditions. These low-cost and open-source data loggers have enabled our research group to collect field data across North and South America on a limited budget, support student projects, and build toward better future scientific data systems.
Wright, Richard L.; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam
2015-01-01
We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments. PMID:26101886
Wright, Richard L; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam
2015-01-01
We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, p<0.01) and 172% greater use within 2 minutes of the use of the water vessel (t(36)=3.51, p = 0.001). We conclude that the loggers were capable of detecting changes in the rates of hand washing with soap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments.
The effect of thermal variance on the phenotype of marine turtle offspring.
Horne, C R; Fuller, W J; Godley, B J; Rhodes, K A; Snape, R; Stokes, K L; Broderick, A C
2014-01-01
Temperature can have a profound effect on the phenotype of reptilian offspring, yet the bulk of current research considers the effects of constant incubation temperatures on offspring morphology, with few studies examining the natural thermal variance that occurs in the wild. Over two consecutive nesting seasons, we placed temperature data loggers in 57 naturally incubating clutches of loggerhead sea turtles Caretta caretta and found that greater diel thermal variance during incubation significantly reduced offspring mass, potentially reducing survival of hatchlings during their journey from the nest to offshore waters and beyond. With predicted scenarios of climate change, behavioral plasticity in nest site selection may be key for the survival of ectothermic species, particularly those with temperature-dependent sex determination.
Asynchronous emergence by loggerhead turtle (Caretta caretta) hatchlings
NASA Astrophysics Data System (ADS)
Houghton, J. D. R.; Hays, G. C.
2001-03-01
For many decades it has been accepted that marine turtle hatchlings from the same nest generally emerge from the sand together. However, for loggerhead turtles (Caretta caretta) nesting on the Greek Island of Kefalonia, a more asynchronous pattern of emergence has been documented. By placing temperature loggers at the top and bottom of nests laid on Kefalonia during 1998, we examined whether this asynchronous emergence was related to the thermal conditions within nests. Pronounced thermal variation existed not only between, but also within, individual nests. These within-nest temperature differences were related to the patterns of hatchling emergence, with hatchlings from nests displaying large thermal ranges emerging over a longer time-scale than those characterised by more uniform temperatures.
Environmental Fluctuations in Forward Scatter and Reverberation
2014-09-30
Experiment 2013 (TREX13) was carried out in ~20 m deep water off Panama City, FL [1]. The Marine Physical Laboratory ( MPL ) participated at-sea aboard the...Sharp). In addition, 16 self-recording temperature loggers were attached to two of the VLAs. Source tows and stations were carried out by MPL on 22...Reverberation Experiment 2013 (TREX13): MPL Trip Report,” Marine Physical Laboratory, Scripps Institution of Oceanography, 13 July 2013 (2013). [3
Robert B. Rummer
1997-01-01
Logging is facing a world of change. A logger?s niche can be defined by terrain, climate, location, timber and product, local government, Federal government, landowners, and mills. The author offers strategies for survival and successful competition.
NASA Astrophysics Data System (ADS)
Stutsel, B.; Callow, J. N.
2017-12-01
Radiant frost events, particularly those during the reproductive stage of winter cereal growth, cost growers millions of dollars in lost yield. Whilst synoptic drivers of frost and factors influencing temperature variation at the landscape scale are relatively well understood, there is a lack of knowledge surrounding small-scale temperature dynamics within paddocks and plot trials. Other work has also suggested a potential significant temperature gradient (several degrees) vertically from ground to canopy, but this is poorly constrained experimentally. Subtle changes in temperature are important as frost damage generally occurs in a very narrow temperature range (-2 to -5°C). Once a variety's damage threshold is reached, a 1°C difference in minimum temperature can increase damage from 10 to 90%. This study applies Distributed Temperature Sensing (DTS) using fibre optics to understand how minimum temperature evolves during a radiant frost. DTS assesses the difference in attenuation of Raman scattering of a light pulse travelling along a fibre optic cable to measure temperature. A bend insensitive multimode fibre was deployed in a double ended duplex configuration as a "fence" run through four times of sowing at a trial site in the Western Australian Wheatbelt. The fibre optic fence was 160m long and 800mm tall with the fibre optic cable spaced 100mm apart vertically, and calibrated in ambient water ( 10 to 15oC) and a chilled glycol ( -8 to-10 oC) baths. The temperature measurements had a spatial resolution of 0.65m and temporal resolution of 60s, providing 2,215 measurements every minute. The results of this study inform our understanding of the subtle temperature changes from the soil to canopy, providing new insight into how to place traditional temperature loggers to monitor frost damage. It also addresses questions of within-trial temperature variability, and provides an example of how novel techniques such as DTS can be used to improve the way temperature (frost) is incorporated in crop damage models. This data set provided by DTS allows a level of detail that is not possible to record with traditional temperature loggers and shows how this emerging technology can be applied to agricultural applications. This research was supported by the Grains Research and Development Corporation National Frost Initiative.
Mor-Bell Logger: Skidding Case Study
Bryce J. Stokes; Jerry L. Koger; Frank J. Pickle
1983-01-01
A production equation was developed for the Mor-Bell logger for skidding while thinning a loblolly pine plantation. Production and costs for skidding and iron gate delimbing were determined for a range of operating conditions.
NASA Astrophysics Data System (ADS)
Wallage, A. L.; Gaughan, J. B.; Lisle, A. T.; Beard, L.; Collins, C. W.; Johnston, S. D.
2017-07-01
Synchronous and continuous measurement of body (BT) and scrotal temperature (ST) without adverse welfare or behavioural interference is essential for understanding thermoregulation of the bull testis. This study compared three technologies for their efficacy for long-term measurement of the relationship between BT and ST by means of (1) temperature sensitive radio transmitters (RT), (2) data loggers (DL) and (3) infrared imaging (IRI). After an initial pilot study on two bulls to establish a surgical protocol, RTs and DLs were implanted into the flank and mid-scrotum of six Wagyu bulls for between 29 and 49 days. RT frequencies were scanned every 15 min, whilst DLs logged every 30 min. Infrared imaging of the body (flank) and scrotum of each bull was recorded hourly for one 24-h period and compared to RT and DL data. After a series of subsequent heat stress studies, bulls were castrated and testicular tissue samples processed for evidence of histopathology. Radio transmitters were less reliable than DLs; RTs lost >11 % of data, whilst 11 of the 12 DLs had 0 % data loss. IRI was only interpretable in 35.8 % of images recorded. Pearson correlations between DL and RT were strong for both BT ( r > 0.94, P < 0.001) and ST ( r > 0.80, P < 0.001). Surgery produced temporary minor inflammation and scrotal hematoma in two animals post-surgery. Whilst scar tissue was observed at all surgical sutured sites when bulls were castrated, there was no evidence of testicular adhesion and normal active spermatogenesis was observed in six of the eight implanted testicles. There was no significant correlation of IRI with either DL or RT. We conclude that DLs provided to be a reliable continuous source of data for synchronous measurement of BT and ST.
NASA Astrophysics Data System (ADS)
Warren, K.; Eppes, M.-C.; Swami, S.; Garbini, J.; Putkonen, J.
2013-11-01
The rates and processes that lead to non-tectonic rock fracture on Earth's surface are widely debated but poorly understood. Few, if any, studies have made the direct observations of rock fracturing under natural conditions that are necessary to directly address this problem. An instrumentation design that enables concurrent high spatial and temporal monitoring resolution of (1) diurnal environmental conditions of a natural boulder and its surroundings in addition to (2) the fracturing of that boulder under natural full-sun exposure is described herein. The surface of a fluvially transported granite boulder was instrumented with (1) six acoustic emission (AE) sensors that record micro-crack associated, elastic wave-generated activity within the three-dimensional space of the boulder, (2) eight rectangular rosette foil strain gages to measure surface strain, (3) eight thermocouples to measure surface temperature, and (4) one surface moisture sensor. Additionally, a soil moisture probe and a full weather station that measures ambient temperature, relative humidity, wind speed, wind direction, barometric pressure, insolation, and precipitation were installed adjacent to the test boulder. AE activity was continuously monitored by one logger while all other variables were acquired by a separate logger every 60 s. The protocols associated with the instrumentation, data acquisition, and analysis are discussed in detail. During the first four months, the deployed boulder experienced almost 12 000 AE events, the majority of which occur in the afternoon when temperatures are decreasing. This paper presents preliminary data that illustrates data validity and typical patterns and behaviors observed. This system offers the potential to (1) obtain an unprecedented record of the natural conditions under which rocks fracture and (2) decipher the mechanical processes that lead to rock fracture at a variety of temporal scales under a range of natural conditions.
NASA Astrophysics Data System (ADS)
Warren, K.; Eppes, M.-C.; Swami, S.; Garbini, J.; Putkonen, J.
2013-07-01
The rates and processes that lead to non-tectonic rock fracture on the Earth's surface are widely debated but poorly understood. Few, if any, studies have made the direct observations of rock fracturing under natural conditions that are necessary to directly address this problem. An instrumentation design that enables concurrent high spatial and temporal monitoring resolution of (1) diurnal environmental conditions of a natural boulder and its surroundings in addition to (2) the fracturing of that boulder under natural full-sun exposure is described herein. The surface of a fluvially transported granite boulder was instrumented with (1) six acoustic emission (AE) sensors that record micro-crack associated, elastic wave-generated activity within the three-dimensional space of the boulder, (2) eight rectangular rosette foil strain gages to measure surface strain, (3) eight thermocouples to measure surface temperature, and (4) one surface moisture sensor. Additionally, a soil moisture probe and a full weather station that measures ambient temperature, relative humidity, wind speed, wind direction, barometric pressure, insolation, and precipitation were installed adjacent to the test boulder. AE activity was continuously monitored by one logger while all other variables were acquired by a separate logger every 60 s. The protocols associated with the instrumentation, data acquisition, and analyses are discussed in detail. During the first four months, the deployed boulder experienced almost 12 000 AE events, the majority of which occur in the afternoon when temperatures are decreasing. This paper presents preliminary data that illustrates data validity and typical patterns and behaviors observed. This system offers the potential to (1) obtain an unprecedented record of the natural conditions under which rocks fracture and (2) decipher the mechanical processes that lead to rock fracture at a variety of temporal scales under a range of natural conditions.
Salas-Morales, Silvia H; Meave, Jorge A; Trejo, Irma
2015-12-01
Globally, climate is a fundamental driver of plant species' geographical distributions, yet we still lack a good understanding of climatic variation on tropical mountains and its consequences for elevational floristic patterns. In a seasonally dry region of southern Mexico, we analysed meteorological patterns along a large elevational gradient (0-3670 m a.s.l.) and examined their relationship with changes in floristic richness. Meteorological patterns were characterised using two data sources. First, climatic information was extracted from cartography and records from a few existing meteorological stations. Additionally, air temperature and humidity were recorded hourly during 1 year with data loggers, at sites representing 200-m elevation increments. Floristic information was extracted from a database containing 10,124 records of plant collections, and organized in 200-m elevational belts. Climatic charts distinguished three climate types along the gradient, all with marked rainfall seasonality, but these bore little correspondence with the information obtained with the data loggers. Mean annual air temperature decreased with increasing elevation (lapse rate of 0.542 °C 100 m(-1)). Thermal oscillation was minimum around 1400 m and increased towards both extremes of the gradient. Relative humidity opposed this pattern, with maxima between 800 and 1800 m, decreasing towards the highest elevations. An analysis of temperature frequency distributions revealed meteorological features undetectable from the annual or monthly means of this variable; despite an overall gradual transition of the proportions of time recorded at different temperatures, some changes did not conform to this pattern. The first discontinuity occurred between 1000-1200 m, where dominant temperatures shifted abruptly; also noticeable was an abrupt increase of the proportion of time elapsed at 0.1-10 °C between 2400 and 2600 m. Air temperature appears to be the most influential climatic factor driving elevational variation of plant species richness in this region.
Data logger technologies for manual wheelchairs: A scoping review.
Routhier, François; Lettre, Josiane; Miller, William C; Borisoff, Jaimie F; Keetch, Kate; Mitchell, Ian M; Research Team, CanWheel
2018-01-01
In recent years, studies have increasingly employed data logger technologies to record objective driving and physiological characteristics of manual wheelchair users. However, the technologies used offer significant differences in characteristics, such as measured outcomes, ease of use, and level of burden. In order to identify and describe the extent of published research activity that relies on data logger technologies for manual wheelchair users, we performed a scoping review of the scientific and gray literature. Five databases were searched: Medline, Compendex, CINAHL, EMBASE, and Google Scholar. The 119 retained papers document a wide variety of logging devices and sensing technologies measuring a range of outcomes. The most commonly used technologies were accelerometers installed on the user (18.8%), odometers installed on the wheelchair (12.4%), accelerometers installed on the wheelchair (9.7%), and heart monitors (9.7%). Not surprisingly, the most reported outcomes were distance, mobility events, heart rate, speed/velocity, acceleration, and driving time. With decreasing costs and technological improvements, data loggers are likely to have future widespread clinical (and even personal) use. Future research may be needed to assess the usefulness of different outcomes and to develop methods more appropriate to wheelchair users in order to optimize the practicality of wheelchair data loggers.
The effect of spiked boots on logger safety, productivity and workload.
Kirk, P; Parker, R
1994-04-01
Analysis of 1657 lost-time logging accidents in the New Zealand logging industry (1985-1991) indicates that 17.5% were as a result of slips, trips and falls and a total of 2870 days were lost. Most (56%) of these slipping, tripping and falling accidents occurred in the felling and delimbing phase of the logging operation, where 37% of the workforce are employed. In an attempt to reduce the number of slipping injuries to loggers employed in felling and delimbing, a study of the effectiveness of spike-soled (caulk) boots was undertaken. Four loggers were intensively observed at work, by continuous time-study methods, while wearing their conventional rubber-soled boots and then spike-soled boots. The number of slips, work methods used, physiological workload and productivity were compared for loggers wearing the two footwear types. Results indicated that spike-soled boots were associated with a significant reduction in the frequency of slips and had no adverse effect on work methods, physiological workload or productivity. Spike-soled boots are now being promoted for use by loggers in New Zealand as a simple method to reduce slipping, tripping and falling accidents.
Walker, Robert; Arima, Eugenio; Messina, Joe; Soares-Filho, Britaldo; Perz, Stephen; Vergara, Dante; Sales, Marcio; Pereira, Ritaumaria; Castro, Williams
2013-01-01
This article addresses the spatial decision-making of loggers and implications for forest fragmentation in the Amazon basin. It provides a behavioral explanation for fragmentation by modeling how loggers build road networks, typically abandoned upon removal of hardwoods. Logging road networks provide access to land, and the settlers who take advantage of them clear fields and pastures that accentuate their spatial signatures. In shaping agricultural activities, these networks organize emergent patterns of forest fragmentation, even though the loggers move elsewhere. The goal of the article is to explicate how loggers shape their road networks, in order to theoretically explain an important type of forest fragmentation found in the Amazon basin, particularly in Brazil. This is accomplished by adapting graph theory to represent the spatial decision-making of loggers, and by implementing computational algorithms that build graphs interpretable as logging road networks. The economic behavior of loggers is conceptualized as a profit maximization problem, and translated into spatial decision-making by establishing a formal correspondence between mathematical graphs and road networks. New computational approaches, adapted from operations research, are used to construct graphs and simulate spatial decision-making as a function of discount rates, land tenure, and topographic constraints. The algorithms employed bracket a range of behavioral settings appropriate for areas of terras de volutas, public lands that have not been set aside for environmental protection, indigenous peoples, or colonization. The simulation target sites are located in or near so-called Terra do Meio, once a major logging frontier in the lower Amazon Basin. Simulation networks are compared to empirical ones identified by remote sensing and then used to draw inferences about factors influencing the spatial behavior of loggers. Results overall suggest that Amazonia's logging road networks induce more fragmentation than necessary to access fixed quantities of wood. The paper concludes by considering implications of the approach and findings for Brazil's move to a system of concession logging.
Beddows, Patricia A; Mallon, Edward K
2018-02-09
A low-cost data logging platform is presented that provides long-term operation in remote or submerged environments. Three premade "breakout boards" from the open-source Arduino ecosystem are assembled into the core of the data logger. Power optimization techniques are presented which extend the operational life of this module-based design to >1 year on three alkaline AA batteries. Robust underwater housings are constructed for these loggers using PVC fittings. Both the logging platform and the enclosures, are easy to build and modify without specialized tools or a significant background in electronics. This combination turns the Cave Pearl data logger into a generalized prototyping system and this design flexibility is demonstrated with two field studies recording drip rates in a cave and water flow in a flooded cave system. This paper describes a complete DIY solution, suitable for a wide range of challenging deployment conditions.
Mallon, Edward K.
2018-01-01
A low-cost data logging platform is presented that provides long-term operation in remote or submerged environments. Three premade “breakout boards” from the open-source Arduino ecosystem are assembled into the core of the data logger. Power optimization techniques are presented which extend the operational life of this module-based design to >1 year on three alkaline AA batteries. Robust underwater housings are constructed for these loggers using PVC fittings. Both the logging platform and the enclosures, are easy to build and modify without specialized tools or a significant background in electronics. This combination turns the Cave Pearl data logger into a generalized prototyping system and this design flexibility is demonstrated with two field studies recording drip rates in a cave and water flow in a flooded cave system. This paper describes a complete DIY solution, suitable for a wide range of challenging deployment conditions. PMID:29425185
Environmental Fluctuations in Forward Scatter and Reverberation
2015-09-30
TREX13) was carried out in ~20 m deep water off Panama City, FL [1]. The Marine Physical Laboratory ( MPL ) participated at-sea aboard the R/V Walton...addition, 16 self-recording temperature loggers were attached to two of the VLAs. Source tows and stations were carried out by MPL on 22-24 April 2013...TREX13): MPL Trip Report,” Marine Physical Laboratory, Scripps Institution of Oceanography, 13 July 2013 (2013). [3] W.S. Hodgkiss, D.E. Ensberg, and
NASA Technical Reports Server (NTRS)
1996-01-01
The Technology Transfer Office at Stennis Space Center worked with a pie company owner to develop an inexpensive container that would protect pies and keep them in a near frozen condition for shipping in 48 hours. A NASA engineer made a thermal barrier envelope from a metalized mylar called 'space blanket material,' developed during the Apollo era. The envelope protects the pies from heat transfer. Pictured, a NASA engineer removes the temperature logger from a pecan pie shipped to him in a prototype envelope.
Acquisition of Ice-Tethered Profilers with Velocity (ITP-V) Instruments for Future Arctic Studies
2016-11-15
instrument that measures sea water temperature and salinity versus depth, the ITP-V adds a multi-axis acoustic -travel-time current meter and...housing capped by an ultra-high-molecular-weight polyethylene dome. The electronics case sits within a foam body designed to provide buoyancy for...then transmits them by satellite to a logger computer at WHO I. The ITP-V instruments add a multi-axis acoustic -travel-time current meter and
Assessing and enhancing the utility of low-cost activity and location sensors for exposure studies.
Asimina, Stamatelopoulou; Chapizanis, D; Karakitsios, S; Kontoroupis, P; Asimakopoulos, D N; Maggos, T; Sarigiannis, D
2018-02-20
Nowadays, the advancement of mobile technology in conjunction with the introduction of the concept of exposome has provided new dynamics to the exposure studies. Since the addressing of health outcomes related to environmental stressors is crucial, the improvement of exposure assessment methodology is of paramount importance. Towards this aim, a pilot study was carried out in the two major cities of Greece (Athens, Thessaloniki), investigating the applicability of commercially available fitness monitors and the Moves App for tracking people's location and activities, as well as for predicting the type of the encountered location, using advanced modeling techniques. Within the frame of the study, 21 individuals were using the Fitbit Flex activity tracker, a temperature logger, and the application Moves App on their smartphones. For the validation of the above equipment, participants were also carrying an Actigraph (activity sensor) and a GPS device. The data collected from Fitbit Flex, the temperature logger, and the GPS (speed) were used as input parameters in an Artificial Neural Network (ANN) model for predicting the type of location. Analysis of the data showed that the Moves App tends to underestimate the daily steps counts in comparison with Fitbit Flex and Actigraph, respectively, while Moves App predicted the movement trajectory of an individual with reasonable accuracy, compared to a dedicated GPS. Finally, the encountered location was successfully predicted by the ANN in most of the cases.
Qin, Chunfu; Bu, Dengpan; Sun, Peng; Zhao, Xiaowei; Zhang, Peihua; Wang, Jiaqi
2017-02-01
The objective of this study was to evaluate the effect of two different forage types on rumen fermentation parameters and profiles using a wireless data logger. Eight lactating cows were randomly assigned to one of two dietary treatments with a low forage diet with corn straw (CS) or a high forage diet with mixed forage (MF) as the forage source, respectively. Dietary physically effective neutral detergent fiber (peNDF) content was 11.3% greater in CS. Dry matter intake and milk fatty acid content decreased upon CS (P < 0.05). Ruminal pH, temperature and oxidation reduction potential (ORP) were monitored for 14 weeks. The CS group had significantly higher pH but lower temperature and ORP compared to MF (P < 0.01). With the CS diet regime, pH at the time before morning feeding, rumination and post-ingestion were significantly higher than those in the MF group (P < 0.05). However, times with the ruminal pH below 6.0 and 5.8 were significantly reduced (P < 0.05), whereas ruminal pH below 5.6 tended to be lower (P = 0.07). The results indicated that rumen fermentation parameters were affected by forage types and dietary peNDF content might be predominant in ruminal pH regulation. © 2016 Japanese Society of Animal Science.
Joyce, Elizabeth M.; Sillett, T. Scott; Holmes, Richard T.
2001-01-01
Quantifying incubation patterns has often involved long observation periods in the field, video cameras, or the use of other electronic devices that sometimes require the partial destruction of clutches and insertion of artificial eggs. In this study, we used an inexpensive, nondestructive method involving temperature probes combined with data loggers to examine the incubation rhythm of female Black-throated Blue Warblers (Dendroica caerulescens). The method provided detailed records of on–off patterns for females for selected 24-h periods during incubation. Female warblers spent an average (±SE) of 64.0% of daylight hours incubating in bouts lasting 20.5 ± 1.5 min and made 2.4 ± 0.1 departures from the nest/h on trips that lasted 10.6 ± 0.7 min. Incubation bouts were longer and females spent more time incubating per hour in the mornings and late afternoons than at mid-day. Older females had longer incubation bouts and tended to have shorter incubation periods than did yearling females, suggesting that experienced individuals were more effective incubators. Because of its ease of use and because nests with probes were not depredated at a higher rate than controls, we suggest that the temperature probe/data logger method is an efficient and effective way to quantify incubation rhythms for open-cup nesting birds.
Validation of triaxial accelerometers to measure the lying behaviour of adult domestic horses.
DuBois, C; Zakrajsek, E; Haley, D B; Merkies, K
2015-01-01
Examining the characteristics of an animal's lying behaviour, such as frequency and duration of lying bouts, has become increasingly relevant for animal welfare research. Triaxial accelerometers have the advantage of being able to continuously monitor an animal's standing and lying behaviour without relying on live observations or video recordings. Multiple models of accelerometers have been validated for use in monitoring dairy cattle; however, no units have been validated for use in equines. This study tested Onset Pendant G data loggers attached to the hind limb of each of two mature Standardbred horses for a period of 5 days. Data loggers were set to record their position every 20 s. Horses were monitored via live observations during the day and by video recordings during the night to compare activity against accelerometer data. All lying events occurred overnight (three to five lying bouts per horse per night). Data collected from the loggers was converted and edited using a macro program to calculate the number of bouts and the length of time each animal spent lying down by hour and by day. A paired t-test showed no significant difference between the video observations and the output from the data loggers (P=0.301). The data loggers did not distinguish standing hipshot from standing square. Predictability, sensitivity, and specificity were all >99%. This study has validated the use of Onset Pendant G data loggers to determine the frequency and duration of standing and lying bouts in adult horses when set to sample and register readings at 20 s intervals.
Cuesta-Frau, David; Varela, Manuel; Aboy, Mateo; Miró-Martínez, Pau
2009-01-01
We describe a device for dual channel body temperature monitoring. The device can operate as a real time monitor or as a data logger, and has Bluetooth capabilities to enable for wireless data download to the computer used for data analysis. The proposed device is capable of sampling temperature at a rate of 1 sample per minute with a resolution of 0.01 °C . The internal memory allows for stand-alone data logging of up to 10 days. The device has a battery life of 50 hours in continuous real-time mode. In addition to describing the proposed device in detail, we report the results of a statistical analysis conducted to assess its accuracy and reproducibility. PMID:22408473
Cuesta-Frau, David; Varela, Manuel; Aboy, Mateo; Miró-Martínez, Pau
2009-01-01
We describe a device for dual channel body temperature monitoring. The device can operate as a real time monitor or as a data logger, and has Bluetooth capabilities to enable for wireless data download to the computer used for data analysis. The proposed device is capable of sampling temperature at a rate of 1 sample per minute with a resolution of 0.01 °C . The internal memory allows for stand-alone data logging of up to 10 days. The device has a battery life of 50 hours in continuous real-time mode. In addition to describing the proposed device in detail, we report the results of a statistical analysis conducted to assess its accuracy and reproducibility.
Evaluating the effectiveness of a logger safety training program.
Bell, Jennifer L; Grushecky, Shawn T
2006-01-01
Logger safety training programs are rarely, if ever, evaluated as to their effectiveness in reducing injuries. Workers' compensation claim rates were used to evaluate the effectiveness of a logger safety training program, the West Virginia Loggers' Safety Initiative (LSI). There was no claim rate decline detected in the majority (67%) of companies that participated in all 4 years of the LSI. Furthermore, their rate did not differ from the rest of the WV logging industry that did not participate in the LSI. Worker turnover was significantly related to claim rates; companies with higher turnover of employees had higher claim rates. Companies using feller bunchers to harvest trees at least part of the time had a significantly lower claim rate than companies not using them. Companies that had more inspections per year had lower claim rates. High injury rates persist even in companies that receive safety training; high employee turnover may affect the efficacy of training programs. The logging industry should be encouraged to facilitate the mechanization of logging tasks, to address barriers to employee retention, and to increase the number of in-the-field performance monitoring inspections. Impact on industry There are many states whose logger safety programs include only about 4-8 hours of safe work practices training. These states may look to West Virginia's expanded training program (the LSI) as a model for their own programs. However, the LSI training may not be reaching loggers due to the delay in administering training to new employees and high levels of employee turnover. Regardless of training status, loggers' claim rates decline significantly the longer they work for a company. It may be that high injury rates in the state of West Virginia would be best addressed by finding ways to encourage and facilitate companies to become more mechanized in their harvesting practices, and to increase employee tenure. Increasing the number of yearly performance inspections may also be a venue to reduce claim rates. Future research could investigate in better detail the working conditions of West Virginia loggers and identify barriers to job tenure, particularly for workers whose primary job task is chainsaw operation. A larger-scale study of the effect of performance monitoring inspections on claim rates is also warranted.
Microchip transponder thermometry for monitoring core body temperature of antelope during capture.
Rey, Benjamin; Fuller, Andrea; Hetem, Robyn S; Lease, Hilary M; Mitchell, Duncan; Meyer, Leith C R
2016-01-01
Hyperthermia is described as the major cause of morbidity and mortality associated with capture, immobilization and restraint of wild animals. Therefore, accurately determining the core body temperature of wild animals during capture is crucial for monitoring hyperthermia and the efficacy of cooling procedures. We investigated if microchip thermometry can accurately reflect core body temperature changes during capture and cooling interventions in the springbok (Antidorcas marsupialis), a medium-sized antelope. Subcutaneous temperature measured with a temperature-sensitive microchip was a weak predictor of core body temperature measured by temperature-sensitive data loggers in the abdominal cavity (R(2)=0.32, bias >2 °C). Temperature-sensitive microchips in the gluteus muscle, however, provided an accurate estimate of core body temperature (R(2)=0.76, bias=0.012 °C). Microchips inserted into muscle therefore provide a convenient and accurate method to measure body temperature continuously in captured antelope, allowing detection of hyperthermia and the efficacy of cooling procedures. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pohl, A; Heuwieser, W; Burfeind, O
2014-07-01
The objective of this study was to evaluate whether milk temperature (MT) measured by automatic milking system (AMS) is a reliable indicator of body temperature of dairy cows and whether cows with fever could be detected. Data loggers (Minilog 8, Vemco Ltd., Halifax, NS, Canada) measuring body temperature were inserted for 7 ± 1 d into the vaginal cavity of 31 dairy cows and programmed to take 1 reading/min. Milk temperature was recorded at each milking event by the AMS, and values from the vaginal loggers were paired with the corresponding MT. The correlation (r) between vaginal temperature (VT) and MT was 0.52. Vaginal temperature was higher (39.1 ± 0.4°C) than MT (38.6 ± 0.7°C) with a mean difference of 0.5 ± 0.6°C. The ability of MT to identify cows with fever was assessed using 2 approaches. In the first approach, VT could indicate fever at any time of the day, whereas MT could display fever only during the milking events of a given day. Different definitions of fever based on thresholds of VT and duration exceeding these thresholds were constructed. Different thresholds of MT were tested to distinguish between cows with and without fever. The combination of 39.0°C as a threshold for MT and 39.5°C for at least 2h/d as a threshold for VT resulted in the highest combination of sensitivity (0.65) and specificity (0.65). In the second approach, we evaluated whether MT could identify cows with fever at a given milking event. A threshold of MT >38.7°C delivered the best combination of sensitivity (0.77) and specificity (0.66) when fever was defined as VT ≥39.5°C. Therefore, MT measured by AMS can be indicative of fever in dairy cows to a limited extent. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Effects of N-acetylcysteine and imipramine in a model of acute rhythm disruption in BALB/c mice.
Pilz, Luísa K; Trojan, Yasmine; Quiles, Caroline L; Benvenutti, Radharani; Melo, Gabriela; Levandovski, Rosa; Hidalgo, Maria Paz L; Elisabetsky, Elaine
2015-03-01
Circadian rhythm disturbances are among the risk factors for depression, but specific animal models are lacking. This study aimed to characterize the effects of acute rhythm disruption in mice and investigate the effects of imipramine and N-acetylcysteine (NAC) on rhythm disruption-induced changes. Mice were exposed to 12:12-hour followed by 10:10-hour light:dark cycles (LD); under the latter, mice were treated with saline, imipramine or NAC. Rhythms of rest/activity and temperature were assessed with actigraphs and iButtons, respectively. Hole-board and social preference tests were performed at the beginning of the experiment and again at the 8th 10:10 LD, when plasma corticosterone and IL-6 levels were also assessed. Actograms showed that the 10:10 LD schedule prevents the entrainment of temperature and activity rhythms for at least 13 cycles. Subsequent light regimen change activity and temperature amplitudes showed similar patterns of decline followed by recovery attempts. During the 10:10 LD schedule, activity and temperature amplitudes were significantly decreased (paired t test), an effect exacerbated by imipramine (ANOVA/SNK). The 10:10 LD schedule increased anxiety (paired t test), an effect prevented by NAC (30 mg/kg). This study identified mild but significant behavioral changes at specific time points after light regimen change. We suggest that if repeated overtime, these subtle changes may contribute to lasting behavioral disturbancess relevant to anxiety and mood disorders. Data suggest that imipramine may contribute to sustained rhythm disturbances, while NAC appears to prevent rhythm disruption-induced anxiety. Associations between sleep/circadian disturbances and the recurrence of depressive episodes underscore the relevance of potential drug-induced maintenance of disturbed rhythms.
A shower before bedtime may improve the sleep onset latency of youth soccer players.
Whitworth-Turner, Craig; Di Michele, Rocco; Muir, Ian; Gregson, Warren; Drust, Barry
2017-10-01
During the competitive season, soccer players are likely exposed to numerous factors that may disrupt the process of sleep. The current investigation looked to evaluate a practical sleep hygiene strategy (10-min showering at ∼40°C before lights out), within a group of 11 youth soccer players in comparison to normal sleeping conditions (control). Each condition consisted of three days within a randomised crossover trial design. Sleep information was collected using a commercial wireless bedside sleep monitor. Measures of skin temperature were evaluated using iButton skin thermistors to establish both distal and proximal skin temperatures and distal to proximal gradient. The shower intervention elevated distal skin temperature by 1.1°C (95% CI: 0.1-2.1°C, p = .04) on average prior to lights out. The elevation in distal temperature was also present during the first 30-min following lights out (1.0°C, 95% CI: 0.4-1.6°C, p < .01). The distal to proximal gradient also showed a significant effect between the conditions within the first 30-min after lights out (0.7°C, 95% CI: 0.3-1.2°C, p < .01). On average the sleep latency of the youth soccer players was -7-min lower (95% CI: -13 to -2 min, p < .01) and sleep efficiency +2% higher (95% CI: 1-3%; p < .01) in the shower condition. These findings demonstrate that a warm shower performed before lights out may offer a practical strategy to promote thermoregulatory changes that may advance sleep onset latency and improve sleep efficiency in athletes.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
... purchase of three hundred acoustic leak detection sensors/loggers (``loggers'') and one fully programmable... and one programmable radio transceiver (Model: Gutermann Zonescan 820) on the basis that there are no...
AcquiControl: Seismic Data Logger Control via iPhone
NASA Astrophysics Data System (ADS)
Golden, S.; Horkley, B.
2010-12-01
Seismic stations are often placed in remote areas, accessible only a few times per year. A typical stand-alone seismic station consists of the seismometer and a data logger, which records the data to attached disk drives or flash memory for later collection by a field crew. Even if the station uses telemetry, maintenance visits may be minimized but rarely entirely avoided. During station visits, field personnel use laptops or handheld devices to control the data logger and seismometer, check their status, and adjust their configuration if necessary. The efficiency and reliability of these on-site quality control tasks has a significant impact on the overall performance of seismic field operations. One widespread seismic data logger is the RT130 by REFTEK Inc., which is traditionally controlled through REFTEK proprietary software designed to run on Palm compatible devices. While this software functions well, compatible Palm handhelds went out of production and are getting hard to find. Also we felt, that its user interface still offered room for improvement. Therefore, we developed a new RT130 control application, named AcquiControl, which runs on Apple’s iPhone or iPod Touch, and features a redesigned, user-friendly interface. The Palm handheld communicates with the data logger through a serial cable. While this is technically also possible with the iPhone or iPod Touch, the production and licensing costs for the required custom cable so far kept us from further pursuing this path. Instead, AcquiControl makes use of the wireless networking capabilities inherent to any iPhone or iPod Touch. To wirelessly connect to an RT130 data logger, we use a wireless-to-serial “dongle” manufactured by Serialio.com, which attaches directly to the data logger’s serial port. First experiments with this setup have shown, that it is actually more convenient to use than a directly attached serial cable, especially during less than ideal environmental conditions such as present while working in the rain. AcquiControl offers a third-party alternative to interface with RT130 data loggers in the field. Currently it covers most frequently used capabilities of the older Palm software through equivalent features, with plans to add more as needed. Beyond that, the application could be easily adapted to support other data loggers than the RT130, possibly even by other manufacturers. This would give users a more uniform interface regardless of data logger model, which could become an advantage during mixed-equipment campaigns. Also, the same software could be expanded to allow the direct input of various field notes, which could be downloaded together with automatically logged configuration data to ease the preparation of seismic metadata or the building of a project-central seismic database.
Allen, J D; Hall, L W; Collier, R J; Smith, J F
2015-01-01
Cattle show several responses to heat load, including spending more time standing. Little is known about what benefit this may provide for the animals. Data from 3 separate cooling management trials were analyzed to investigate the relationship between behavioral patterns in lactating dairy cows experiencing mild to moderate heat stress and their body temperature. Cows (n=157) were each fitted with a leg data logger that measured position and an intravaginal data logger that measures core body temperature (CBT). Ambient conditions were also collected. All data were standardized to 5-min intervals, and information was divided into several categories: when standing and lying bouts were initiated and the continuance of each bout (7,963 lying and 6,276 standing bouts). In one location, cows were continuously subjected to heat-stress levels according to temperature-humidity index (THI) range (THI≥72). The THI range for the other 2 locations was below and above a heat-stress threshold of 72 THI. Overall and regardless of period of day, cows stood up at greater CBT compared with continuing to stand or switching to a lying position. In contrast, cows lay down at lower CBT compared with continuing to lie or switching to a standing position, and lying bouts lasted longer when cows had lower CBT. Standing bouts also lasted longer when cattle had greater CBT, and they were less likely to lie down (less than 50% of lying bouts initiated) when their body temperature was over 38.8°C. Also, cow standing behavior was affected once THI reached 68. Increasing CBT decreased lying duration and increased standing duration. A CBT of 38.93°C marked a 50% likelihood a cow would be standing. This is the first physiological evidence that standing may help cool cows and provides insight into a communally observed behavioral response to heat. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
A novel design for sap flux data acquisition in large research plots using open source components
NASA Astrophysics Data System (ADS)
Hawthorne, D. A.; Oishi, A. C.
2017-12-01
Sap flux sensors are a widely-used tool for estimating in-situ, tree-level transpiration rates. These probes are installed in the stems of multiple trees within a study area and are typically left in place throughout the year. Sensors vary in their design and theory of operation, but all require electrical power for a heating element and produce at least one analog signal that must be digitized for storage. There are two topologies traditionally adopted to energize these sensors and gather the data from them. In one, a single data logger and power source are used. Dedicated cables radiate out from the logger to supply power to each of the probes and retrieve analog signals. In the other layout, a standalone data logger is located at each monitored tree. Batteries must then be distributed throughout the plot to service these loggers. We present a hybrid solution based on industrial control systems that employs a central data logger and battery, but co-locates digitizing hardware with the sensors at each tree. Each hardware node is able to communicate and share power over wire links with neighboring nodes. The resulting network provides a fault-tolerant path between the logger and each sensor. The approach is optimized to limit disturbance of the study plot, protect signal integrity and to enhance system reliability. This open-source implementation is built on the Arduino micro-controller system and employs RS485 and Modbus communications protocols. It is supported by laptop based management software coded in Python. The system is designed to be readily fabricated and programmed by non-experts. It works with a variety of sap-flux measurement techniques and it is able to interface to additional environmental sensors.
Students' Perceived Heat-Health Symptoms Increased with Warmer Classroom Temperatures.
Bidassey-Manilal, Shalin; Wright, Caradee Y; Engelbrecht, Jacobus C; Albers, Patricia N; Garland, Rebecca M; Matooane, Mamopeli
2016-06-07
Temperatures in Africa are expected to increase by the end of the century. Heat-related health impacts and perceived health symptoms are potentially a problem, especially in public schools with limited resources. Students (n = 252) aged ~14-18 years from eight high schools completed an hourly heat-health symptom log over 5 days. Data loggers measured indoor classroom temperatures. A high proportion of students felt tired (97.2%), had low concentration (96.8%) and felt sleepy (94.1%) during at least one hour on any day. There were statistically significant correlations, when controlling for school cluster effect and time of day, between indoor temperatures ≥32 °C and students who felt tired and found it hard to breathe. Consistently higher indoor classroom temperatures were observed in classrooms constructed of prefabricated asbestos sheeting with corrugated iron roof and converted shipping container compared to brick classrooms. Longitudinal studies in multiple seasons and different classroom building types are needed.
Improving vaccination cold chain in the general practice setting.
Page, Sue L; Earnest, Arul; Birden, Hudson; Deaker, Rachelle; Clark, Chris
2008-10-01
This study compared temperature control in different types of vaccine storing refrigerators in general practice and tested knowledge of general practice staff in vaccine storage requirements. Temperature data loggers were set to serially record the temperature within vaccine refrigerators in 28 general practices, recording at 12 minute intervals over a period of 10 days on each occasion. A survey of vaccine storage knowledge and records of divisions of general practice immunisation contacts were also obtained. There was a significant relationship between type of refrigerator and optimal temperature, with the odds ratio for bar style refrigerator being 0.005 (95% CI: 0.001-0.044) compared to the purpose built vaccine refrigerators. Score on a survey of vaccine storage was also positively associated with optimal storage temperature. General practices that invest in purpose built vaccine refrigerators will achieve standards of vaccine cold chain maintenance significantly more reliably than can be achieved through regular cold chain monitoring and practice supports.
Atheull, Adolphe Nfotabong; Din, Ndongo; Longonje, Simon N; Koedam, Nico; Dahdouh-Guebas, Farid
2009-11-17
Worldwide there is growing research interest in the ethnobiology of mangrove forests. Notwithstanding that, little information has been published about ethnobiology of mangrove forests in Cameroon. The aims of this study were a) to analyze the harvesting methods and the local selling of mangrove wood products by loggers in the vicinity of Wouri estuary and b) to investigate the patterns of subsistence uses of mangrove wood products around the Douala-Edea reserve. Semi-structured interviews were conducted with 120 active mangrove loggers in 23 Douala wood markets and 103 households located in three villages (Mbiako, Yoyo I and Yoyo II) close to Douala-Edea reserve. In each of the three densely populated villages, every second household was chosen for sampling while in all markets, mangrove loggers were chosen randomly. In addition, log diameters were measured in each market using a wooden foldable tape measure. A post hoc analysis (Newman-Keuls test) was performed in order to detect the common wood class diameter sold in the Douala wood markets. The analysis of the loggers' survey data has shown that large logs of Rhizophora with diameter greater than 40 cm were common in the Douala wood markets and were more closely associated with loggers who used chainsaws. In addition to the general mangroves wood products selling, the analysis on a subsistence level (households' survey) suggests the local population's dependence on mangroves, with multiple uses of Rhizophora racemosa Meyer, R. harrisonii Leechman, Avicennia germinans L. Stearn., Laguncularia racemosa Gaertn. f. and Conocarpus erectus L. timbers for furniture, fences, smoking fish, and fuelwood. Finally, Nypa fruticans (Thunb.) Wurmb. leaves were used as thatching material for house walls and roofs. Our findings revealed that big logs of Rhizophora were commonly sold by the loggers. A majority of loggers (60%) reported that mangrove marketed wood constitute a principal source of income. Most of the villagers (85.83%) often depend on mangroves for subsistence needs and for them there is no substitute for mangrove wood. Therefore, more efforts should be undertaken at the national level to implement conservation, management and sustainable use of these coastal forests.
2009-01-01
Background Worldwide there is growing research interest in the ethnobiology of mangrove forests. Notwithstanding that, little information has been published about ethnobiology of mangrove forests in Cameroon. The aims of this study were a) to analyze the harvesting methods and the local selling of mangrove wood products by loggers in the vicinity of Wouri estuary and b) to investigate the patterns of subsistence uses of mangrove wood products around the Douala-Edea reserve. Methods Semi-structured interviews were conducted with 120 active mangrove loggers in 23 Douala wood markets and 103 households located in three villages (Mbiako, Yoyo I and Yoyo II) close to Douala-Edea reserve. In each of the three densely populated villages, every second household was chosen for sampling while in all markets, mangrove loggers were chosen randomly. In addition, log diameters were measured in each market using a wooden foldable tape measure. A post hoc analysis (Newman-Keuls test) was performed in order to detect the common wood class diameter sold in the Douala wood markets. Results The analysis of the loggers' survey data has shown that large logs of Rhizophora with diameter greater than 40 cm were common in the Douala wood markets and were more closely associated with loggers who used chainsaws. In addition to the general mangroves wood products selling, the analysis on a subsistence level (households' survey) suggests the local population's dependence on mangroves, with multiple uses of Rhizophora racemosa Meyer, R. harrisonii Leechman, Avicennia germinans L. Stearn., Laguncularia racemosa Gaertn. f. and Conocarpus erectus L. timbers for furniture, fences, smoking fish, and fuelwood. Finally, Nypa fruticans (Thunb.) Wurmb. leaves were used as thatching material for house walls and roofs. Conclusion Our findings revealed that big logs of Rhizophora were commonly sold by the loggers. A majority of loggers (60%) reported that mangrove marketed wood constitute a principal source of income. Most of the villagers (85.83%) often depend on mangroves for subsistence needs and for them there is no substitute for mangrove wood. Therefore, more efforts should be undertaken at the national level to implement conservation, management and sustainable use of these coastal forests. PMID:19919680
Skin temperature response to a liquid meal intake is different in men than in women.
Martinez-Tellez, Borja; Ortiz-Alvarez, Lourdes; Sanchez-Delgado, Guillermo; Xu, Huiwen; Acosta, Francisco M; Merchan-Ramirez, Elisa; Muñoz-Hernandez, Victoria; Martinez-Avila, Wendy D; Contreras-Gomez, Miguel A; Gil, Angel; Labayen, Idoia; Ruiz, Jonatan R
2018-06-02
The thermic effect of food (TEF) refers to the increase of the metabolic rate and body temperature in response to a single meal. To date, most of the studies have focused to determine the TEF in terms of energy expenditure, but little is known about which is the response in terms of skin temperature. The aim of this study was to analyze whether the thermic effect of food (TEF) on the skin temperature with a standardized and individualized liquid meal test is different in young adult men than in young adult women. A total of 104 young adults (36 men and 68 women, age: 18-25 years old) consumed a standardized and individualized liquid meal (energy intake: 50% of measured basal metabolic rate, 50% carbohydrates, 35% fat, 15% protein). The skin temperature was measured by means of 17 iButtons during 3 h and 20 min. The mean, proximal, distal, and supraclavicular skin temperature, as well as the peripheral gradient, were determined as a proxy of a peripheral vasoconstriction. The participants reported the thermal sensation of the whole body, clavicular, feet, and hands zones. The body composition was measured by dual X-ray absorptiometry. The overall, mean, proximal, and supraclavicular skin temperature significantly increased after the meal intake (all P < 0.05 vs. the baseline temperature). There was a postprandial peripheral vasoconstriction right after the meal intake and over the first hour and a peripheral vasodilatation during the second and third hour. Women had a higher increase in all skin temperature parameters in comparison to men (all, P < 0.05), whereas there were no sex differences in the proximal skin temperature (P = 0.279). The pattern of thermal sensation was similar between sexes, but women always felt colder than men. All of the results persisted after adjusting the analyses for body composition or menstrual cycle. A standardized and individualized liquid meal test increases the skin temperature in young adults, being the thermic effect higher in women than in men. Copyright © 2018 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
NASA Technical Reports Server (NTRS)
Jovic, Srboljub
2015-01-01
This document provides the software design description for the two core software components, the LVC Gateway, the LVC Gateway Toolbox, and two participants, the LVC Gateway Data Logger and the SAA Processor (SaaProc).
Krawczel, P D; Klaiber, L M; Thibeau, S S; Dann, H M
2012-08-01
Assessing feeding behavior is important in understanding the effects of nutrition and management on the well-being of dairy cows. Historically, collection of these data from cows fed with a Calan Broadbent Feeding System (American Calan Inc., Northwood, NH) required the labor-intensive practices of direct observation or video review. The objective of this study was to evaluate the agreement between the output of a HOBO change-of-state data logger (Onset Computer Corp., Bourne, MA), mounted to the door shell and latch plate, and video data summarized with continuous sampling. Data (number of feed bin visits per day and feeding time in minutes per day) were recorded with both methods from 26 lactating cows and 10 nonlactating cows for 3 d per cow (n=108). The agreement of the data logger and video methods was evaluated using the REG procedure of SAS to compare the mean response of the methods against the difference between the methods. The maximum allowable difference (MAD) was set at ±3 for bin visits and ±20 min for feeding time. Ranges for feed bin visits (2 to 140 per d) and feeding time (28 to 267 min/d) were established from video data. Using the complete data set, agreement was partially established between the data logger and video methods for feed bin visits, but not established for feeding time. The complete data set generated by the data logger was screened to remove visits of a duration ≤3 s, reflecting a cow unable to enter a feed bin (representing 7% of all data) and ≥5,400 s, reflecting a failure of the data logger to align properly with its corresponding magnetic field (representing <1% of all data). Using the resulting screened data set, agreement was established for feed bin visits and feeding time. For bin visits, 4% of the data was beyond the MAD. For feeding time, 3% of the data was beyond the MAD and 74% of the data was ±1 min. The insignificant P-value, low coefficient of determination, and concentration of the data within the MAD indicate the agreement of the change-of-state data logger and video data. This suggests the usage of a change-of-state data logger to assess the feeding behavior of cows feeding from a Calan Broadbent Feeding System is appropriate. Use of the screening criteria for data analysis is recommended. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Clinicians’ and researchers’ perspectives on manual wheelchair data loggers
Routhier, François; Lettre, Josiane; Miller, William C.; Borisoff, Jaimie F.; Keetch, Kate; Mitchell, Ian M.
2017-01-01
Recent studies have employed data loggers to record a wide range of, sometimes differing, objective outcomes associated with the use of manual wheelchairs. To identify which outcomes are broadly perceived to be the most important to measure when objectively documenting manual wheelchair use, a cross-sectional survey was conducted with groups of researchers and clinicians in the field of wheeled mobility. We also surveyed the challenges these groups experienced when using data loggers. The survey was informed by a previous scoping review of the scientific and gray literature. Seventy-four people, with various academic and professional backgrounds, completed the survey: 57 researchers (77.0%) and 17 clinicians (23.0%). Regarding the importance they attributed to commonly measured outcomes, the most highly rated outcome identified by both groups was “distance traveled.” There were significant differences between the groups’ perspectives in rating and ranking the importance of “pressure-relief activities”, “seat pressure” and “acceleration.” In terms of challenges or barriers associated with the use of data loggers for monitoring manual wheelchair use, it appears that researchers and clinicians have relatively similar needs and preferences. However, only clinicians reported that the time they wanted to, or could, allocate to review recorded information was a potential hardship. Our hope is that these results will help further development and increase the functionality and applicability of data loggers for manual wheelchairs in research and clinical contexts. PMID:28202382
Inexistence of permafrost at the top of the Veleta peak (Sierra Nevada)
NASA Astrophysics Data System (ADS)
Gómez-Ortiz, Antonio; Salvador-Franch, Ferran; Salvà-Catarineu, Montserrat; Oliva, Marc; Palacios, David; Tanarro, Luis Miguel; Schulte, Lothar
2014-05-01
Several deep drillings wew carried out along a latitudinal transect from Svalbard (78°N) to Sierra Nevada (37°N, Spain) within the project Permafrost and Climate Change in Europe (PACE). In this abstract we discuss the data corresponding to the drilling existing at the top of the Veleta peak, at an altitude of 3380 m. This drilling reach a depth of 114.5 m depth, although we analyze here the data of the first 60 m depth. UTL-1 loggers were installed at depths of 0.2, 0.6, 1.2, 2.6, 4, 7, 10, 13, 15, 20 and 60 m. The observation period spans from 2002 to 2013 with data being taken every 2 h. The most surficial loggersrecorded the largest annual temperature oscillations, reaching 22.6°C at 20 cm. Down to 10 m depth the annual temperature amplitude is still remarkable and seasonal temperature changes are even observed at depths of 15 to 20 m. Below this level the temperature remains constant. The logger installed at 60 m depth recorded small temperature changes between 2006 and 2009, oscillating between 2.38 and 2.61ºC. Since January 2010 the temperatures stabilized at 2.61°C. However, this slight temperature increase must be framed within the margin of instrumentation error of the devices. Data shows evidence of the inexistence ofpermanent negative temperatures at depth. In contrast to what happens in the nearby Veleta cirque floor (3100 m), where marginal permafrost conditions have been recorded, in the Veleta peak (3380 m) data points to the absence of a permafrost regime. This may be due to several factors: a) The existence of permafrost in the Veletacirque is directly related to the presence of fossil glacier ice corresponding to a glacier that existed there during the Little Ice Age. b ) The early melting of snow cover in the Veleta peak due to wind effect and incidence of solar radiation condition the absence of permafrost conditions at the summitin contrast to the Veleta cirquefloor, where the longer persistence of snow favours the presence of continuous negative temperatures. c) The topographical setting of the Veleta peak favours a major incidence of radiation through therock walls,conditioning higher temperatures.
Williams, C.T.; Sheriff, M.J.; Schmutz, J.A.; Kohl, F.; Toien, O.; Buck, C.L.; Barnes, B.M.
2011-01-01
Precise measures of phenology are critical to understanding how animals organize their annual cycles and how individuals and populations respond to climate-induced changes in physical and ecological stressors. We show that patterns of core body temperature (T b) can be used to precisely determine the timing of key seasonal events including hibernation, mating and parturition, and immergence and emergence from the hibernacula in free-living arctic ground squirrels (Urocitellus parryii). Using temperature loggers that recorded T b every 20 min for up to 18 months, we monitored core T b from three females that subsequently gave birth in captivity and from 66 female and 57 male ground squirrels free-living in the northern foothills of the Brooks Range Alaska. In addition, dates of emergence from hibernation were visually confirmed for four free-living male squirrels. Average T b in captive females decreased by 0.5–1.0°C during gestation and abruptly increased by 1–1.5°C on the day of parturition. In free-living females, similar shifts in T b were observed in 78% (n = 9) of yearlings and 94% (n = 31) of adults; females without the shift are assumed not to have given birth. Three of four ground squirrels for which dates of emergence from hibernation were visually confirmed did not exhibit obvious diurnal rhythms in T b until they first emerged onto the surface when T b patterns became diurnal. In free-living males undergoing reproductive maturation, this pre-emergence euthermic interval averaged 20.4 days (n = 56). T b-loggers represent a cost-effective and logistically feasible method to precisely investigate the phenology of reproduction and hibernation in ground squirrels.
Loggers' Views on Training After Attending a Three-Day Educational Program.
ERIC Educational Resources Information Center
Reeb, James E.
1996-01-01
Surveyed 120 loggers who attended a 3-day educational program on first aid and adult cardiopulmonary resuscitation, forest ecology and silviculture, woods safety, and small business management. Results indicate that the training was worthwhile to the participants and they would be willing to attend additional training. (JRH)
BOREAS RSS-17 Stem, Soil, and Air Temperature Data
NASA Technical Reports Server (NTRS)
Zimmerman, Reiner; McDonald, Kyle C.; Way, JoBea; Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Smith, David E. (Technical Monitor)
2000-01-01
The BOREAS RSS-17 team collected several data sets in support of its research in monitoring and analyzing environmental and phenological states using radar data. This data set consists of tree bole and soil temperature measurements from various BOREAS flux tower sites. Temperatures were measured with thermistors implanted in the hydroconductive tissue of the trunks of several trees at each site and at various depths in the soil. Data were stored on a data logger at intervals of either 1 or 2 hours. The majority of the data were acquired between early 1994 and early 1995. The primary product of this data set is the diurnal stem temperature measurements acquired for selected trees at five BOREAS tower sites. The data are provided in tabular ASCII format. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
Turbidity threshold sampling for suspended sediment load estimation
Jack Lewis; Rand Eads
2001-01-01
Abstract - The paper discusses an automated procedure for measuring turbidity and sampling suspended sediment. The basic equipment consists of a programmable data logger, an in situ turbidimeter, a pumping sampler, and a stage-measuring device. The data logger program employs turbidity to govern sample collection during each transport event. Mounting configurations and...
Characteristics of West Virginia loggers during economically difficult times
Ben Spong; Jinxing Wang; David Summerfield
2011-01-01
West Virginia licensed loggers have been surveyed over the years regarding their business, operational, and personal characteristics. An update of this study was completed in 2009 to illustrate the impacts of the current economic conditions on the forestry and forest products industries. Additionally, this survey will help demonstrate the preparedness of the logging...
A portable system for characterizing wildland fire behavior
Bret Butler; D. Jimenez; J. Forthofer; K. Shannon; Paul Sopko
2010-01-01
A field deployable system for quantifying energy and mass transport in wildland fires is described. The system consists of two enclosures: The first is a sensor/data logger combination package that allows characterization of convective/radiant energy transport in fires. This package contains batteries, a programmable data logger, sensors, and other electronics. The...
One Year of Data of Scimpi Borehole Measurements
NASA Astrophysics Data System (ADS)
Insua, T. L.; Moran, K.; Kulin, I.; Farrington, S.; Newman, J. B.; Riedel, M.; Scherwath, M.; Heesemann, M.; Pirenne, B.; Iturrino, G. J.; Masterson, W.; Furman, C.
2014-12-01
The Simple Cabled Instrument for Measuring Parameters In-Situ (SCIMPI) is a new subseafloor observatory designed to study dynamic processes in the subseabed using a simple and low-cost approach compared to a Circulation Obviation Retrofit Kit (CORK). SCIMPI was successfully installed at the Integrated Ocean Drilling Program (IODP) Site U1416 during IODP Expedition 341S in May 2013. SCIMPI is designed to measure pore pressure, temperature and electrical resistivity over time in a borehole. The first SCIMPI prototype comprises nine modules joined in a single array by flexible cables. Multiple floats keep the system taut against a sinker bar weight located on SCIMPI and resting on the bottom of the borehole. All the modules record temperature and electrical resistivity, and three are also equipped with pressure sensors. Currently, SCIMPI operates as an autonomous instrument with a data logger that is recovered using an ROV. The second recovery of the SCIMPI data logger took place during the Ocean Networks Canada maintenance cruise, Wiring the Abyss 2014, on May 25th, 2014. The pressure sensor data show a stable trend in which tidal effects are observed in through the one year deployment. The temperature measurements in all the modules became stable over time with smaller variations over the last several months. The only temperature sensor differing from this trend is the shallowest, located at 8 meters below seafloor. This module shows a sudden spike of ~20°C that on April 5th, 2014, an event that was repeated several times from April 25th until recovery of modules. The electrical resistivity sensors show variations over time that could be related to gas hydrate dynamics at the Site. Interpretation of these data is speculative at this time but borehole-sealing processes as well as the formation of gas hydrate are potential processes influencing the recordings. SCIMPI will soon be connected to Ocean Networks Canada's NEPTUNE observatory at Clayoquot Slope node to provide real-time data from this subseafloor observatory.
First direct evidence of long-distance seasonal movements and hibernation in a migratory bat
Weller, Theodore J.; Castle, Kevin T.; Liechti, Felix; Hein, Cris D.; Schirmacher, Michael R.; Cryan, Paul M.
2016-01-01
Understanding of migration in small bats has been constrained by limitations of techniques that were labor-intensive, provided coarse levels of resolution, or were limited to population-level inferences. Knowledge of movements and behaviors of individual bats have been unknowable because of limitations in size of tracking devices and methods to attach them for long periods. We used sutures to attach miniature global positioning system (GPS) tags and data loggers that recorded light levels, activity, and temperature to male hoary bats (Lasiurus cinereus). Results from recovered GPS tags illustrated profound differences among movement patterns by individuals, including one that completed a >1000 km round-trip journey during October 2014. Data loggers allowed us to record sub-hourly patterns of activity and torpor use, in one case over a period of 224 days that spanned an entire winter. In this latter bat, we documented 5 torpor bouts that lasted ≥16 days and a flightless period that lasted 40 nights. These first uses of miniature tags on small bats allowed us to discover that male hoary bats can make multi-directional movements during the migratory season and sometimes hibernate for an entire winter.
Turning a $10 Computer into a Powerful DIY Data Logger
NASA Astrophysics Data System (ADS)
Schilperoort, B.
2017-12-01
Due the rapid advance of consumer electronics, much more powerful and cheaper options are available for DIY projects. The $10 `Raspberry Pi Zero W' computer, with abilities like WiFi, Bluetooth, HDMI video output, and a large cheap memory, can be used for data logging purposes. The computer has a range of input and output pins on the board, with which virtually every type of digital sensor communication is possible. With an extra component, analog measurements can also be made. An extra option is the addition of a camera, which can be connected straight to the board. However, due to the relatively high power consumption (0.5 - 0.7 Watt), the `Zero W' is not optimal for off-the-grid locations. For ease of use, the collected data can be downloaded over a local WiFi network using your smartphone or a laptop. No extra software or skills are needed, it is as simple as visiting a webpage and pressing download, making data collection a quick and easy task. With simple step by step instructions you can set up your own data logger, to collect data from sensors ranging from simple temperature and water level measurements, to sonic anemometers.
Clinicians' and Researchers' Perspectives on Manual Wheelchair Data Loggers.
Routhier, François; Lettre, Josiane; Miller, William C; Borisoff, Jaimie F; Keetch, Kate; Mitchell, Ian M
2017-07-01
Recent studies have used data loggers to record a wide range of, sometimes differing, objective outcomes associated with the use of manual wheelchairs. To identify which outcomes are broadly perceived to be the most important to measure when objectively documenting manual wheelchair use, a cross-sectional survey was conducted with groups of researchers and clinicians in the field of wheeled mobility. We also surveyed the challenges these groups experienced when using data loggers. The survey was informed by a previous scoping review of the scientific and gray literature. Seventy-four people with various academic and professional backgrounds completed the survey: 57 researchers (77.0%) and 17 clinicians (23.0%). Regarding the importance they attributed to commonly measured outcomes, the most highly rated outcome identified by both groups was "distance traveled." There were significant differences between the groups' perspectives in rating and ranking the importance of "pressure-relief activities," "seat pressure," and "acceleration." In terms of challenges or barriers associated with the use of data loggers for monitoring manual wheelchair use, it appears that researchers and clinicians have relatively similar needs and preferences. However, only clinicians reported that the time they wanted to, or could, allocate to review recorded information was a potential hardship. Our hope is that these results will help further development and increase the functionality and applicability of data loggers for manual wheelchairs in research and clinical contexts. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Dadgar, S; Lee, E S; Leer, T L V; Burlinguette, N; Classen, H L; Crowe, T G; Shand, P J
2010-05-01
This study investigated the effect of microclimate temperature during preslaughter transportation on chicken meat quality. Ninety broilers per load of 2,900 were monitored individually during 3 to 4 h of preslaughter transport in an actively ventilated trailer. Six transport test runs were conducted at average ambient temperatures of -27, -22, -17, -5, +4, and +11 degrees C. Birds were classified into 4 groups based upon the temperatures recorded in their immediate surroundings as follows: -16 to 0, 0 to 10, 10 to 20, and 20 to 30 degrees C. Internal body temperatures of the birds were recorded using Thermocron DS1922L iButtons. Birds were slaughtered in a commercial facility and meat quality of the chilled carcasses was evaluated by determination of pH, color, drip loss, thaw loss, cook loss, shear force, water-binding capacity, and pellet cook yield of the pectoralis major muscle. The breast meat from birds exposed to temperatures below 0 degrees C showed a significantly higher (P < 0.05) ultimate pH. Breast meat from birds exposed to temperatures below 0 degrees C showed significantly higher (P < 0.05) ultimate pH, a* value, water-binding capacity, and pellet cook yield and a significantly lower L* compared with breast meat of birds exposed to temperatures above 0 degrees C. The average core body temperatures were significantly lower (P < 0.05) during transport for birds exposed to temperatures below 0 degrees C compared with those exposed to temperatures between 0 and 10 degrees C. The latter birds had significantly lower (P < 0.05) core body temperatures compared with those exposed to temperatures above 10 degrees C. Thaw loss was significantly higher (P < 0.05) for breast meat of birds exposed to temperatures above 20 degrees C during transportation. There was no significant trend for b* value, drip loss, cook loss, or shear values based on environment temperature immediately surrounding the birds. Exposure to temperatures below 0 degrees C increased the incidence of dark, firm, and dry breast meat and decreased the incidence of pale, soft, and exudative breast meat. These results demonstrate that preslaughter transport may influence breast meat quality characteristics of broiler chicken.
Comfort in High-Performance Homes in a Hot-Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, A.; Beach, R.
2016-01-01
IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature alsomore » was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees Fahrenheit for 5% of the time.« less
Present and future thermal environments available to Sharp-tailed Grouse in an intact grassland.
Raynor, Edward J; Powell, Larkin A; Schacht, Walter H
2018-01-01
Better understanding animal ecology in terms of thermal habitat use has become a focus of ecological studies, in large part due to the predicted temperature increases associated with global climate change. To further our knowledge on how ground-nesting endotherms respond to thermal landscapes, we examined the thermal ecology of Sharp-tailed Grouse (Tympanuchus phasianellus) during the nesting period. We measured site-specific iButton temperatures (TiB) and vegetation characteristics at nest sites, nearby random sites, and landscape sites to assess thermal patterns at scales relevant to nesting birds. We asked if microhabitat vegetation characteristics at nest sites matched the characteristics that directed macrohabitat nest-site selection. Grouse selected sites sheltered by dense vegetation for nesting that moderated TiB on average up to 2.7°C more than available landscape sites. Successful nests were positioned in a way that reduced exposure to thermal extremes by as much as 4°C relative to failed nests with an overall mean daytime difference (±SE) of 0.4 ±0.03°C. We found that macrohabitat nest-site selection was guided by dense vegetation cover and minimal bare ground as also seen at the microhabitat scale. Global climate projections for 2080 suggest that TiB at nest sites may approach temperatures currently avoided on the landscape, emphasizing a need for future conservation plans that acknowledge fine-scale thermal space in climate change scenarios. These data show that features of grassland landscapes can buffer organisms from unfavorable microclimatic conditions and highlight how thermal heterogeneity at the individual-level can drive decisions guiding nest site selection.
Present and future thermal environments available to Sharp-tailed Grouse in an intact grassland
Powell, Larkin A.; Schacht, Walter H.
2018-01-01
Better understanding animal ecology in terms of thermal habitat use has become a focus of ecological studies, in large part due to the predicted temperature increases associated with global climate change. To further our knowledge on how ground-nesting endotherms respond to thermal landscapes, we examined the thermal ecology of Sharp-tailed Grouse (Tympanuchus phasianellus) during the nesting period. We measured site-specific iButton temperatures (TiB) and vegetation characteristics at nest sites, nearby random sites, and landscape sites to assess thermal patterns at scales relevant to nesting birds. We asked if microhabitat vegetation characteristics at nest sites matched the characteristics that directed macrohabitat nest-site selection. Grouse selected sites sheltered by dense vegetation for nesting that moderated TiB on average up to 2.7°C more than available landscape sites. Successful nests were positioned in a way that reduced exposure to thermal extremes by as much as 4°C relative to failed nests with an overall mean daytime difference (±SE) of 0.4 ±0.03°C. We found that macrohabitat nest-site selection was guided by dense vegetation cover and minimal bare ground as also seen at the microhabitat scale. Global climate projections for 2080 suggest that TiB at nest sites may approach temperatures currently avoided on the landscape, emphasizing a need for future conservation plans that acknowledge fine-scale thermal space in climate change scenarios. These data show that features of grassland landscapes can buffer organisms from unfavorable microclimatic conditions and highlight how thermal heterogeneity at the individual-level can drive decisions guiding nest site selection. PMID:29415080
NASA Astrophysics Data System (ADS)
Kuras, E. R.; Hondula, D. M.; Brown-Saracino, J.
2015-10-01
Urban environmental health hazards, including exposure to extreme heat, have become increasingly important to understand in light of ongoing climate change and urbanization. In cities, neighborhoods are often considered a homogenous and appropriate unit with which to assess heat risk. This manuscript presents results from a pilot study examining the variability of individually experienced temperatures (IETs) within a single urban neighborhood. In July 2013, 23 research participants were recruited from the South End neighborhood of Boston and equipped with Thermochron iButtons that measured the air temperatures surrounding individuals as they went about their daily lives. IETs were measured during a heat wave period (July 17-20), which included 2 days with excessive heat warnings and 1 day with a heat advisory, as well as a reference period (July 20-23) in which temperatures were below seasonal averages. IETs were not homogeneous during the heat wave period; mean IETs were significantly different between participants ( p < 0.001). The majority of participants recorded IETs significantly lower than outdoor ambient temperatures (OATs), and on average, the mean IET was 3.7 °C below the mean OAT. Compared with IETs during the reference period, IETs during the heat wave period were 1.0 °C higher. More than half of participants did not experience statistically different temperatures between the two test periods, despite the fact that the mean OAT was 6.5 °C higher during the heat wave period. The IET data collected for this sample and study period suggest that (1) heterogeneity in individual heat exposure exists within this neighborhood and that (2) outdoor temperatures misrepresent the mean experienced temperatures during a heat wave period. Individual differences in attributes (gender, race, socioeconomic status, etc.), behaviors (schedules, preferences, lifestyle, etc.), and access to resources are overlooked determinants of heat exposure and should be better integrated with group- and neighborhood-level characteristics. Understanding IETs for the population at large may lead to innovative advances in heat-health intervention and mitigation strategies.
Working safely in summertime heat
Robert B. Rummer
1997-01-01
As logging operations continue in the hotter months of he year, the safety hazard of heat stress appears. Loggers are particularly at risk, because the combination of hard physical work and outdoor conditions puts high demands on the body. While loggers rarely die from heat stress, they may suffer heat illness symptoms ranging from the discomfort of heat rash to nausea...
The Role of Communicative Feedback in Successful Water Conservation Programs
ERIC Educational Resources Information Center
Tom, Gail; Tauchus, Gail; Williams, Jared; Tong, Stephanie
2011-01-01
The Sacramento County Water Agency has made available 2 water conservation programs to its customers. The Data Logger Program attaches the Meter Master Model 100 EL data logger to the customer's water meter for 1 week and provides a detailed report of water usage from each fixture. The Water Wise House Call Program provides findings and…
ERIC Educational Resources Information Center
Tosa, Sachiko; Martin, Fred
2010-01-01
This study examined how a professional development program which incorporates the use of electronic data-loggers could impact on science teachers' attitudes towards inquiry-based teaching. The participants were 28 science or technology teachers who attended workshops offered in the United States and Japan. The professional development program…
Mapping Topoclimate and Microclimate in the Monarch Butterfly Biosphere Reserve, Mexico
NASA Astrophysics Data System (ADS)
Weiss, S. B.
2006-12-01
Overwintering monarch butterflies in Mexico select areas of the high elevation Oyamel fir -pine forest providing a canopy that protects them from extremes of cold, heat, sun, and wind. These exacting microclimatic conditions are found in relatively small areas of forest with appropriate topography and canopy cover. The major goal of this investigation is to map topoclimatic and microclimatic conditions within the Monarch Butterfly Biosphere Reserve by combining temperature monitoring (iButton Thermochrons), hemispherical canopy photography, multiple regression, and GIS modeling. Temperature measurements included base weather stations and arrays of Thermochrons (on the north-side of trees at 2m height) across local topographic and canopy cover gradients. Topoclimatic models of minimum temperatures included topographic position, slope, and elevation, and predicted that thermal belts on slopes and cold air drainage into canyons create local minimum temperature gradients of 2°C. Topoclimatic models of maximum temperatures models included elevation, topographic position, and relative solar exposure, with local gradients of 3°C. These models, which are independent of forest canopy structure, were then projected across the entire region. Forest canopy structure, including direct and diffuse solar radiation, was assessed with hemispherical photography at each Thermochron site. Canopy cover affected minimum temperatures primarily on the calmest, coldest nights. Maximum temperatures were predicted by direct radiation below the canopy. Fine- scale grids (25 m spacing) at three overwintering sites characterized effects of canopy gaps and edges on temperature and wind exposure. The effects of temperature variation were considered for lipid loss rates, ability to take flight, and freezing mortality. Lipid loss rates were estimated by measured hourly temperatures. Many of the closed canopy sites allowed for substantial lipid reserves at the end of the season (March 15), but increases in average temperature could effectively deplete lipids by that time. The large influence of canopy cover on daytime maximum temperatures demonstrates that forest thinning directly reduces habitat suitability. Monarchs' flight behavior under warmer conditions suggests that daytime temperatures drive the dynamics of monarch distribution within colonies. Thinning also decreases nighttime minimum temperatures, and increases wind exposure. These results create a basis for quantitative understanding of the combinations of topography and forest structure that provide high quality overwintering habitat.
222Rn variations in Mystery Cave, Minnesota
Lively, R.S.; Krafthefer, B.C.
1995-01-01
222Rn concentrations and meteorological parameters were measured at 4- h intervals over a 2-y period in Mystery Cave, southeastern Minnesota. Continuous radon monitors and meteorological sensors connected to data loggers were installed at several locations along commercial tour routes. 222Rn concentrations ranged as high as 25 kBq m-3 in summer and 20 kBq m-3 in winter. Average winter concentrations were lower than summer by at least a factor of two. Seasonal radon variations were correlative with outside air temperatures. During the winter, radon concentrations were observed to fluctuate periodically by factors of 20 or more in under 24 h. Both the long- and short-term variations are correlative with temperature- induced mixing of cave air with surface air.
Brünnich's guillemots (Uria lomvia) maintain high temperature in the body core during dives.
Niizuma, Yasuaki; Gabrielsen, Geir W; Sato, Katsufumi; Watanuki, Yutaka; Naito, Yasuhiko
2007-06-01
A major challenge for diving birds, reptiles, and mammals is regulating body temperature while conserving oxygen through a reduction in metabolic processes. To gain insight into how these needs are met, we measured dive depth and body temperatures at the core or periphery between the skin and abdominal muscles simultaneously in freely diving Brünnich's guillemots (Uria lomvia), an arctic seabird, using an implantable data logger (16-mm diameter, 50-mm length, 14-g mass, Little Leonardo Ltd., Tokyo). Guillemots exhibited increased body core temperatures, but decreased peripheral temperatures, during diving. Heat conservation within the body core appeared to result from the combined effect of peripheral vasoconstriction and a high wing beat frequency that generates heat. Conversely, the observed tissue hypothermia in the periphery should reduce metabolic processes as well as heat loss to the water. These physiological effects are likely one of the key physiological adaptations that makes guillemots to perform as an efficient predator in arctic waters.
Students’ Perceived Heat-Health Symptoms Increased with Warmer Classroom Temperatures
Bidassey-Manilal, Shalin; Wright, Caradee Y.; Engelbrecht, Jacobus C.; Albers, Patricia N.; Garland, Rebecca M.; Matooane, Mamopeli
2016-01-01
Temperatures in Africa are expected to increase by the end of the century. Heat-related health impacts and perceived health symptoms are potentially a problem, especially in public schools with limited resources. Students (n = 252) aged ~14–18 years from eight high schools completed an hourly heat-health symptom log over 5 days. Data loggers measured indoor classroom temperatures. A high proportion of students felt tired (97.2%), had low concentration (96.8%) and felt sleepy (94.1%) during at least one hour on any day. There were statistically significant correlations, when controlling for school cluster effect and time of day, between indoor temperatures ≥32 °C and students who felt tired and found it hard to breathe. Consistently higher indoor classroom temperatures were observed in classrooms constructed of prefabricated asbestos sheeting with corrugated iron roof and converted shipping container compared to brick classrooms. Longitudinal studies in multiple seasons and different classroom building types are needed. PMID:27338423
Measuring and mapping rock wall permafrost across Norway
NASA Astrophysics Data System (ADS)
Magnin, Florence; Etzelmuller, Bernd; Hilger, Paula; Westermann, Sebastian; Isaksen, Ketil; Hermans, Reginald
2017-04-01
The investigation of rock wall permafrost is of high relevance for geohazards assessment and for understanding cold-climate landscape evolution since its changes over time can cause slope instability and trigger rock falls. The destabilization of steep slopes is a serious threat to human activities and lives in Norway, especially because most of rock walls lie directly above houses, infrastructures and large water bodies with potential of high-energy displacement waves. Rock wall permafrost has been investigated since the early 2010s in alpine massifs of western Norway thanks to the CryoLINK project (2008-2011). The CryoWALL project (2015-2019) aims at extending this preliminary study to the nation-wide scale. It consists in systematic measurements of rock surface temperature (RST) in order model and to map the spatial distribution of rock wall permafrost. In between August 2015 and August 2016, 20 RST loggers (Geoprecision mini data loggers, accuracy ± 0.1°C, precision 0.01°C, sensors PT1000) were installed at 10 cm depth of 7 selected sites. These loggers are distributed along a latitudinal transect (from 60°50'N to 69°46'N), cover various elevations and sun-exposures, and are completed by 4 other loggers installed in Jotunheimen in 2009 and 2010. The RST time series are used for (a) characterizing the distribution of rock wall permafrost across Norway, (b) running steady-state and transient numerical models of rock wall permafrost at selected sites, and to (c) calibrate a general linear regression model that will be used to (d) predict the spatial distribution of rock wall permafrost at the national scale. In this communication we will introduce the RST measurement installations and sites, as well as the first RST records that encompass 6 years of continuous measurements in Jotunheimen, and 1 year of record for 13 other loggers. The preliminary analysis shows that RST differs by 3°C between N and S faces in Southern Norway, with mean annual RST as low as -1.9°C at 1700 m a.s.l in a N face (Nordfjord, Sogn of Fjordane) during the measurement year which was about 0.8°C above normal (1981-2010). In Northern Norway, the RST difference between N and S faces is rather around 1.5°C due to the midnight sun and polar night effects, inducing similar RST in both aspects during December, January, May and June. Negative mean annual RST is found as low as 1200 m a.s.l in S-exposed faces (Kåfjorden, Troms) during the measurement year which was 1.1°C above normal in this area. The ice and snow coating the rock faces during winter appears as a significant warming factor that can raise the mean annual RST up to at least 1°C compared to bare rock conditions. This first data set is shown to be of high relevance for predictive modelling.
Production and Costs of the Chambers Delimbinator in First Thinning of Pine Plantations
Scott T. Mooney; Kevin D. Boston; W. Dale Greene
2000-01-01
Production and quality measures were collected and analyzed for a new chain-flail delimbing machine, Chambers Delimbinator, on two operations in central and southwestern Georgia. The first operation, Logger A, used two skidders and one loader while the second operation, Logger B, used two skidder and two loaders. Lobber B with the lower cycle time and larger piece...
Potential for shared log transport services
Tim McDonald; Steve Taylor; Jorge Valenzuela
2001-01-01
A simulation model of a log transport logistics network was developed. The model could be structured to either share truck capacity among a group of loggers, or to assign a fixed number of trucks to individual loggers. Another variation of the model allowed the use of a staging yard to set out loaded trailers and deliver them to destinations using dedicated shuttle...
An inexpensive and reliable monitoring station design for use with lightweight, compact data loggers
Ronald S., Jr. Zalesny; Adam H. Wiese; Edmund O. Bauer; William L., Jr. Headlee; Richard B. Hall; A. Assibi Mahama; Jill A. Zalesny
2007-01-01
We designed, constructed, and field-tested an inexpensive and reliable monitoring station that can be used with lightweight, compact data loggers. We feel this design, improved three times over 6 yr, could benefit anyone in nursery or field settings interested in acquiring environmental data. We provide step-by-step instructions on the construction of the monitoring...
Environmental Heat Stress Among Young Working Women: A Pilot Study.
Rahman, Juma; Fakhruddin, S H M; Rahman, A K M Fazlur; Halim, M A
Heat waves are increasing significantly in frequency and severity and threaten the health and income of outdoor workers. Pregnant women workers are particularly at risk due to their delicate physiological systems and accountabilities to future generations. Animal and human studies propose that elevated body temperatures during pregnancy can induce adverse pregnancy outcomes. To measure the change in internal body temperature (Tcore) in young working women before, after, and during work (both outdoor and indoor) on hot humid days and relate threshold temperature to the upshot adverse effects of pregnancy (teratogenicity and related miscarriage). Tympanic temperatures were measured using infrared ear thermometers and workplace temperatures were collected using Lascar Data Logger. Brief exploratory interviews were conducted to gather qualitative data, and content analysis was also carried out. Body temperatures were found elevated among outdoor women workers compared with that of indoor women workers. The present study found that outdoor work during pregnancy in hot, humid days might increase body temperature up to levels that could induce fetal destruction or anomaly. Copyright © 2016 Icahn School of Medicine at Mount Sinai. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.
2017-04-01
Groundwater thermally enhanced by the Urban Heat Island effect can be utilised by ground source heating systems (GSHSs). However, the near subsurface is subject to seasonal temperature variation reflected in shallow groundwater that can differ by several degrees throughout the year. To sustainably manage the near surface thermal resource an understanding of factors which control variation in groundwater temperature and how these are transmitted through the aquifer is needed. We show that even in relatively small urban areas (Cardiff, U.K., situated on a shallow gravel aquifer) the Zone of Seasonal Fluctuation (ZSF) can vary in depth by 8m. GSHSs are more efficient if they are sited below the ZSF, where temperatures are more stable. In Spring 2014, 48 groundwater monitoring boreholes were profiled at a 1m resolution to measure groundwater temperature across Cardiff. These were reprofiled that Autumn and compared to the Spring temperatures, defining the ZSF. The average depth to the base of the ZSF was 9.5mbgl but ranged from 7.1-15.5mbgl. The amplitude of the differences between Spring and Autumn temperatures also varied. To better understand the high spatial variability 60 boreholes were instrumented with in situ temperature loggers, recording at half-hourly intervals. The first year's data revealed the amplitudes of temperature variation within boreholes with loggers at similar depths were not always consistent. It was also noted that lag times between air temperature and groundwater temperature were not uniform across the sites. The data also showed that where gravels occurred at shallower depths the ZSF tended to be shallower and lag times shorter. The wide spatial variability of the ZSF may be partially explained by differing landuse. Those boreholes in open, grassed areas showed a deeper ZSF than those in built-up areas but built-up areas generally showed the greatest variation between Spring and Autumn temperature profiles, suggesting heat loss from buildings and underground infrastructure plays a part. Natural and anthropogenic factors affecting spatial and temporal groundwater temperatures, either separately or in combination, that have been considered in this study include landuse, depth, lithology/lithostratigraphy, material properties, hydrogeological setting, thermal conductivity, buried infrastructure, land surface temperature, weather effects and solar radiation. This study shows that urban groundwater temperatures can vary greatly across a small area, which has implications for the successful development, and long-term performance of open- and closed-loop GSHSs, and the environmental regulation of these systems. Key to the effective wide-scale use of GSHSs is an understanding of the hydrogeological setting, chiefly how heat is transferred across the aquifer. This study attempts to provide insight into an array of factors which determine heat transfer in the ZSF.
Identify the dominant variables to predict stream water temperature
NASA Astrophysics Data System (ADS)
Chien, H.; Flagler, J.
2016-12-01
Stream water temperature is a critical variable controlling water quality and the health of aquatic ecosystems. Accurate prediction of water temperature and the assessment of the impacts of environmental variables on water temperature variation are critical for water resources management, particularly in the context of water quality and aquatic ecosystem sustainability. The objective of this study is to measure stream water temperature and air temperature and to examine the importance of streamflow on stream water temperature prediction. The measured stream water temperature and air temperature will be used to test two hypotheses: 1) streamflow is a relatively more important factor than air temperature in regulating water temperature, and 2) by combining air temperature and streamflow data stream water temperature can be more accurately estimated. Water and air temperature data loggers are placed at two USGS stream gauge stations #01362357and #01362370, located in the upper Esopus Creek watershed in Phonecia, NY. The ARIMA (autoregressive integrated moving average) time series model is used to analyze the measured water temperature data, identify the dominant environmental variables, and predict the water temperature with identified dominant variable. The preliminary results show that streamflow is not a significant variable in predicting stream water temperature at both USGS gauge stations. Daily mean air temperature is sufficient to predict stream water temperature at this site scale.
Mitchell, Diane C; Castro, Javier; Armitage, Tracey L; Vega-Arroyo, Alondra J; Moyce, Sally C; Tancredi, Daniel J; Bennett, Deborah H; Jones, James H; Kjellstrom, Tord; Schenker, Marc B
2017-07-01
The California heat illness prevention study (CHIPS) devised methodology and collected physiological data to assess heat related illness (HRI) risk in Latino farmworkers. Bilingual researchers monitored HRI across a workshift, recording core temperature, work rate (metabolic equivalents [METs]), and heart rate at minute intervals. Hydration status was assessed by changes in weight and blood osmolality. Personal data loggers and a weather station measured exposure to heat. Interviewer administered questionnaires were used to collect demographic and occupational information. California farmworkers (n = 588) were assessed. Acceptable quality data was obtained from 80% of participants (core temperature) to 100% of participants (weight change). Workers (8.3%) experienced a core body temperature more than or equal to 38.5 °C and 11.8% experienced dehydration (lost more than 1.5% of body weight). Methodology is presented for the first comprehensive physiological assessment of HRI risk in California farmworkers.
Boriboonsomsin, Kanok; Durbin, Thomas; Scora, George; Johnson, Kent; Sandez, Daniel; Vu, Alexander; Jiang, Yu; Burnette, Andrew; Yoon, Seungju; Collins, John; Dai, Zhen; Fulper, Carl; Kishan, Sandeep; Sabisch, Michael; Jackson, Doug
2018-06-01
Real-world vehicle and engine activity data were collected from 90 heavy-duty vehicles in California, United States, most of which have engine model year 2010 or newer and are equipped with selective catalytic reduction (SCR). The 90 vehicles represent 19 different groups defined by a combination of vocational use and geographic region. The data were collected using advanced data loggers that recorded vehicle speed, position (latitude and longitude), and more than 170 engine and aftertreatment parameters (including engine load and exhaust temperature) at the frequency of one Hz. This article presents plots of real-world exhaust temperature and engine load distributions for the 19 vehicle groups. In each plot, both frequency distribution and cumulative frequency distribution are shown. These distributions are generated using the aggregated data from all vehicle samples in each group.
Forin-Wiart, Marie-Amélie; Hubert, Pauline; Sirguey, Pascal; Poulle, Marie-Lazarine
2015-01-01
Recently developed low-cost Global Positioning System (GPS) data loggers are promising tools for wildlife research because of their affordability for low-budget projects and ability to simultaneously track a greater number of individuals compared with expensive built-in wildlife GPS. However, the reliability of these devices must be carefully examined because they were not developed to track wildlife. This study aimed to assess the performance and accuracy of commercially available GPS data loggers for the first time using the same methods applied to test built-in wildlife GPS. The effects of antenna position, fix interval and habitat on the fix-success rate (FSR) and location error (LE) of CatLog data loggers were investigated in stationary tests, whereas the effects of animal movements on these errors were investigated in motion tests. The units operated well and presented consistent performance and accuracy over time in stationary tests, and the FSR was good for all antenna positions and fix intervals. However, the LE was affected by the GPS antenna and fix interval. Furthermore, completely or partially obstructed habitats reduced the FSR by up to 80% in households and increased the LE. Movement across habitats had no effect on the FSR, whereas forest habitat influenced the LE. Finally, the mean FSR (0.90 ± 0.26) and LE (15.4 ± 10.1 m) values from low-cost GPS data loggers were comparable to those of built-in wildlife GPS collars (71.6% of fixes with LE < 10 m for motion tests), thus confirming their suitability for use in wildlife studies. PMID:26086958
NASA Astrophysics Data System (ADS)
Hut, Rolf; Bogaard, Thom
2017-04-01
Throwing something in a river and seeing how fast it floats downstream is the first thing that every hydrologists does when encountering a new river. Using a collection of floats allows estimation of gauge surface water velocity and dispersion characteristics. To use floats over long (hundreds of kilometers) stretches of river requires either a crew that keeps an eye on the floats (labor intensive) or having high-tech floats that upload their location on regular intervals, such that they can be retrieved at the end of the experiment. GPS floats with communication units have been custom build by scientists before. Connecting GPS units to GSM modems used to require deep knowledge on micro-electronics and network protocols. In this work we present a version that is build using only off-the-shelf electronics that require no deep knowledge of either micro electronics nor network protocols. The new cellular enabled Particle Electron development board made it possible to connect a Sparkfun OpenLog (SD-card based logger) to a GPS tracker with no soldering and little programming. Because scientist can program the device themselves, settings like sample time can be adapted to the needs of specific experiments and additional sensors can be easily added. When writing GPS location every minute to SD and reporting every fifteen minutes online, our logger can run for three days on a single 2200 mAh LiPo battery (provided with the Particle Electron). Cost of components for our logger is less than 150. The durability of our GPS loggers will be tested during a field campaign at the end of January 2017 where 15 floats will float down the Irrawaddy river over a length of more than 200 km, during two days.
Kunkle, Gerald A.
2016-05-04
The procedures followed and the results obtained from the testing are described in this publication. The device met most of the manufacturer’s stated specifications. An exception was power consumption, which was about 10 percent above the manufacturer’s specifications. It was also observed that enabling WiFi doubles the Storm 3’s power consumption. In addition, several logging errors were made by two units during deployment testing, but it could not be determined whether these errors were the fault of the Storm or of an attached sensor.
Badia-Melis, Ricardo; Ruiz-Garcia, Luis; Garcia-Hierro, Javier; Villalba, Jose I Robla
2015-02-26
Every day, millions of tons of temperature-sensitive goods are produced, transported, stored or distributed worldwide, thus making their temperature and humidity control essential. Quality control and monitoring of goods during the cold chain is an increasing concern for producers, suppliers, logistic decision makers and consumers. In this paper we present the results of a combination of RFID and WSN devices in a set of studies performed in three commercial wholesale chambers of 1848 m3 with different set points and products. Up to 90 semi-passive RFID temperature loggers were installed simultaneously together with seven motes, during one week in each chamber. 3D temperature mapping charts were obtained and also the psychrometric data model from ASABE was implemented for the calculation of enthalpy changes and the absolute water content of air. Thus thank to the feedback of data, between RFID and WSN it is possible to estimate energy consumption in the cold room, water loss from the products and detect any condensation over the stored commodities.
Badia-Melis, Ricardo; Ruiz-Garcia, Luis; Garcia-Hierro, Javier; Villalba, Jose I. Robla
2015-01-01
Every day, millions of tons of temperature-sensitive goods are produced, transported, stored or distributed worldwide, thus making their temperature and humidity control essential. Quality control and monitoring of goods during the cold chain is an increasing concern for producers, suppliers, logistic decision makers and consumers. In this paper we present the results of a combination of RFID and WSN devices in a set of studies performed in three commercial wholesale chambers of 1848 m3 with different set points and products. Up to 90 semi-passive RFID temperature loggers were installed simultaneously together with seven motes, during one week in each chamber. 3D temperature mapping charts were obtained and also the psychrometric data model from ASABE was implemented for the calculation of enthalpy changes and the absolute water content of air. Thus thank to the feedback of data, between RFID and WSN it is possible to estimate energy consumption in the cold room, water loss from the products and detect any condensation over the stored commodities. PMID:25730482
Impacts of land use and land cover on surface and air temperature in urban landscapes
NASA Astrophysics Data System (ADS)
Crum, S.; Jenerette, D.
2015-12-01
Accelerating urbanization affects regional climate as the result of changing land cover and land use (LCLU). Urban land cover composition may provide valuable insight into relationships among urbanization, air, and land-surface temperature (Ta and LST, respectively). Climate may alter these relationships, where hotter climates experience larger LULC effects. To address these hypotheses we examined links between Ta, LST, LCLU, and vegetation across an urban coastal to desert climate gradient in southern California, USA. Using surface temperature radiometers, continuously measuring LST on standardized asphalt, concrete, and turf grass surfaces across the climate gradient, we found a 7.2°C and 4.6°C temperature decrease from asphalt to vegetated cover in the coast and desert, respectively. There is 131% more temporal variation in asphalt than turf grass surfaces, but 37% less temporal variation in concrete than turf grass. For concrete and turf grass surfaces, temporal variation in temperature increased from coast to desert. Using ground-based thermal imagery, measuring LST for 24 h sequences over citrus orchard and industrial use locations, we found a 14.5°C temperature decrease from industrial to orchard land use types (38.4°C and 23.9°C, respectively). Additionally, industrial land use types have 209% more spatial variation than orchard (CV=0.20 and 0.09, respectively). Using a network of 300 Ta (iButton) sensors mounted in city street trees throughout the region and hyperspectral imagery data we found urban vegetation greenness, measured using the normalized difference vegetation index (NDVI), was negatively correlated to Ta at night across the climate gradient. Contrasting previous findings, the closest coupling between NDVI and Ta is at the coast from 0000 h to 0800 h (highest r2 = 0.6, P < 0.05) while relationships at the desert are weaker (highest r2 = 0.38, P < 0.05). These findings indicate that vegetation cover in urbanized regions of southern California, USA decrease Ta and LST and spatial variation in LST, while built surfaces and land uses have the opposite effect. Furthermore these relationships are regulated by regional climate patterns, with decreases in Ta and LST being strongest in the coastal sub-region.
Floating Probe Assembly for Measuring Temperature of Water
NASA Technical Reports Server (NTRS)
Stewart, Randy; Ruffin, Clyde
2002-01-01
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (=71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in.(=1.9 cm) thick and 2.5 in. (=6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger.
Floating Probe Assembly for Measuring Temperature of Water
NASA Technical Reports Server (NTRS)
Selinsky, T.; Stewart, Randy; Ruffin, Clyde
2002-01-01
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (approx. = 71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in. (approx. = 1.9 cm) thick and 2.5 in. (approx. = 6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger. This work was done by Randy
Energy balance measurements over a small reservoir in Ghana's Upper East Region
NASA Astrophysics Data System (ADS)
van de Giesen, Nick; Ohene Annor, Frank
2013-04-01
Near the small village of Binaba (10.778927 deg N, 0.464859 deg E), a small irrigation reservoir has been instrumented to measure different parts of the energy balance of this water body. Instruments were placed on, or attached to, a spar platform. This platform consisted of a long PVC pipe, the spar, which is closed at the bottom. On the PVC pipe rests an aluminum frame platform that carries instrumentation and solar power panel. In turn, the platform rests partially on a large inflated tire. At the bottom of the PVC pipe, lead weights and batteries were placed to ensure a very low point of gravity to minimize wave impact on the platform movement. The tire ensures a large second moment of the water plane. The combination of large second momentum of the water plane and small displacement, ensures a high placement of the metacenter. The distance between the point of gravity and the metacenter is relatively long and the weight is large due to the weights and batteries. This ensures that the eigenfrequency of the platform is very low. On the platform, we fixed a WindMaster Pro (sonic anemometer for 3D wind speed and air temperature to perform eddy covariance measurements of sensible heat flux), a NR Lite (net radiometer), and air temperature and relative humidity sensors. Water temperature at different depths was measured with a string of TidbiT's (waterproof temperature sensors and loggers). The platform had a wind vane and the spar could turn freely around its anchor cable to ensure that the anemometer always faced upwind. A compass in the logger completed this setup. First results suggest, as expected, that the sensible heat flux is relatively small with on average 20 W/m2 over the course of a day. Sensible heat flux peaked around midnight at 35 W/m2, when the warm water warmed up the air from the colder surrounding land. The dynamics of heat storage during the daytime and longwave radiation during the night time, are important to calculate the latent heat flux.
Optimal Configuration and Deployment of Software on Multi-Core Processing Architectures
2008-07-01
between the event generating threads and the collector thread is implemented through semaphores . The Perseus data logger is designed to minimize the...performance counters (through the PAPI API) and opens up access to the shared memory logger through a semaphore and Remote Procedure Call (RPC) buffer... synchronization events. Using this rich data, the TMAM is able to output all of the information necessary to identify precisely which pairs of thread
Monitoring of a 1 kWp Solar Photovoltaic System
NASA Astrophysics Data System (ADS)
Malek, M. F.; Zainuddin, H.; Rejab, S. N. M.; Shaari, S. N.; Shaari, S.; Omar, A. M.; Rusop, M.
2009-06-01
A 1 kWp `stand alone' PV system consists of 4 module (2 BP SX75U module and 2 BP 275F module), inverter, 2 thermocouple, 3 voltage sensor, 3 current sensor, 4 battery and data logger (Data Taker DT80) has been set up. This research involve nine parameters which are irradiance (Ia), ambient temperature (Tamb), module temperature (Tmod), module voltage (Vmod), battery voltage (Vbat), load voltage (Vload), module current (Imod), battery current (Ibat) and load current (Iload). All parameters were measured using the equipments and sensors that connected directly to data logger (Data Taker DT80) to interpret and show the data on computer using the Delogger sofware. The data then was transferred into the computer and analyzed using the Deview and Microsoft Excel software to determine the performance indices for the stand alone PV system. From the analysis a few performance indices were determined. The range of daily solar irradiation is between 2.20 kWhm-2 to 4.00 kWhm-2, while the range of total global irradiation is between 5.76 kWh to 10.48 kWh. For daily total energy yield, the range is between 0.23 kWh d-1 to 0.28 kWh d-1. The range for clearness index is between 0.49% to 0.89%. The range for final yield is between 0.77 kWh d-1 kWp-1 to 0.93 kWhd-1 kWp-1 while the range of array efficiency is between 2.53% to 4.65%. Lastly, the range of the performance ratio is between 22.08% to 40.58%.
A spatiotemporal analysis of hydrological patterns based on a wireless sensor network system
NASA Astrophysics Data System (ADS)
Plaza, F.; Slater, T. A.; Zhong, X.; Li, Y.; Liang, Y.; Liang, X.
2017-12-01
Understanding complicated spatiotemporal patterns of eco-hydrological variables at a small scale plays a profound role in improving predictability of high resolution distributed hydrological models. However, accurate and continuous monitoring of these complex patterns has become one of the main challenges in the environmental sciences. Wireless sensor networks (WSNs) have emerged as one of the most widespread potential solutions to achieve this. This study presents a spatiotemporal analysis of hydrological patterns (e.g., soil moisture, soil water potential, soil temperature and transpiration) based on observational data collected from a dense multi-hop wireless sensor network (WSN) in a steep-forested testbed located in Southwestern Pennsylvania, USA. At this WSN testbed with an approximate area of 3000 m2, environmental variables are collected from over 240 sensors that are connected to more than 100 heterogeneous motes. The sensors include the soil moisture of EC-5, soil temperature and soil water potential of MPS-1 and MPS-2, and sap flow sensors constructed in house. The motes consist of MICAz, IRIS and TelosB. In addition, several data loggers have been installed along the site to provide a comparative reference to the WSN measurements for the purpose of checking the WSN data quality. The edaphic properties monitored by the WSN sensors show strong agreement with the data logger measurements. Moreover, sap flow measurements, scaled to tree stand transpiration, are found to be reasonable. This study also investigates the feasibility and roles that these sensor measurements play in improving the performance of high-resolution distributed hydrological models. In particular, we explore this using a modified version of the Distributed Hydrological Soil Vegetation Model (DHSVM).
NASA Astrophysics Data System (ADS)
Chien, H.; McGlinn, L.
2017-12-01
The upper Esopus Creek and its tributary streams located in the Catskill Mountain region of New York State provide habitats for cold-adapted aquatic species. However, ongoing global warming may change the stream water temperature within a watershed and disturb the persistence of coldwater habitats. Characterizing thermal regimes within the upper Esopus Creek watershed is important to provide information of thermally suitable habitats for aquatic species. The objectives of this study are to measure stream water temperature and map thermal variability among tributaries to the Esopus Creek and within Esopus Creek. These objectives will be achieved by measuring stream water temperature for at least two years. More than 100 water temperature data loggers have been placed in the upper Esopus Creek and their tributaries to collect 30-minute interval water temperatures. With the measured water temperature, we will use spatial interpolation in ArcGIS to create weekly and monthly water temperature surface maps to evaluate the thermal variation over time and space within the upper Esopus Creek watershed. We will characterize responsiveness of water temperature in tributary streams to air temperature as well. This information of spatial and temporal variation of stream water temperature will assist stream managers with prioritizing management practices that maintain or enhance connectivity of thermally suitable habitats in high priority areas.
Thomas, Ellen M; Chapman, Benjamin; Jaykus, Lee-Ann; Phister, Trevor
2014-09-01
Contaminated fresh produce has been increasingly identified as a cause of foodborne illnesses. Because of concerns about pathogen growth on these food items at retail, the 2009 U.S. Food and Drug Administration Food Code established that cut leafy greens (lettuce, spinach, spring mix, cabbage, arugula, and kale) must have time and temperature controls for safety and hence should be kept at refrigerated temperatures (5°C or lower). The purpose of this study was to determine the temperature profiles of cut leafy greens in single-serving clamshell containers provided as part of the North Carolina School Lunch Program and to compare the two policies that North Carolina has in place to control the temperature of these products (the 3-day rule and time in lieu of temperature). Temperatures were recorded with data loggers in 24 schools during a 3-day period. In all cases, substantial temperature variability was found for these products, including temperatures above 5°C for at least 1 h on each of the 3 days. In some cases, temperatures reached above 5°C for more than 3 h throughout the serving time. The results demonstrate the importance of developing a protocol for continuous temperature monitoring of leafy greens served in school lunch programs.
Wills, C A; Beaupre, S J
2000-01-01
Most reptiles maintain their body temperatures within normal functional ranges through behavioral thermoregulation. Under some circumstances, thermoregulation may be a time-consuming activity, and thermoregulatory needs may impose significant constraints on the activities of ectotherms. A necessary (but not sufficient) condition for demonstrating thermoregulation is a difference between observed body temperature distributions and available operative temperature distributions. We examined operative and body temperature distributions of the timber rattlesnake (Crotalus horridus) for evidence of thermoregulation. Specifically, we compared the distribution of available operative temperatures in the environment to snake body temperatures during August and September. Operative temperatures were measured using 48 physical models that were randomly deployed in the environment and connected to a Campbell CR-21X data logger. Body temperatures (n=1,803) were recorded from 12 radiotagged snakes using temperature-sensitive telemetry. Separate randomization tests were conducted for each hour of day within each month. Actual body temperature distributions differed significantly from operative temperature distributions at most time points considered. Thus, C. horridus exhibits a necessary (but not sufficient) condition for demonstrating thermoregulation. However, unlike some desert ectotherms, we found no compelling evidence for thermal constraints on surface activity. Randomization may prove to be a powerful technique for drawing inferences about thermoregulation without reliance on studies of laboratory thermal preference.
Body temperature stability achieved by the large body mass of sea turtles.
Sato, Katsufumi
2014-10-15
To investigate the thermal characteristics of large reptiles living in water, temperature data were continuously recorded from 16 free-ranging loggerhead turtles, Caretta caretta, during internesting periods using data loggers. Core body temperatures were 0.7-1.7°C higher than ambient water temperatures and were kept relatively constant. Unsteady numerical simulations using a spherical thermodynamic model provided mechanistic explanations for these phenomena, and the body temperature responses to fluctuating water temperature can be simply explained by a large body mass with a constant thermal diffusivity and a heat production rate rather than physiological thermoregulation. By contrast, body temperatures increased 2.6-5.1°C in 107-152 min during their emergences to nest on land. The estimated heat production rates on land were 7.4-10.5 times the calculated values in the sea. The theoretical prediction that temperature difference between body and water temperatures would increase according to the body size was confirmed by empirical data recorded from several species of sea turtles. Comparing previously reported data, the internesting intervals of leatherback, green and loggerhead turtles were shorter when the body temperatures were higher. Sea turtles seem to benefit from a passive thermoregulatory strategy, which depends primarily on the physical attributes of their large body masses. © 2014. Published by The Company of Biologists Ltd.
2013-06-14
CAPE CANAVERAL, Fla. –Outredgeous red romaine lettuce plants grow inside in a prototype VEGGIE flight pillow. The bellows of the hardware have been lowered to better observe the plants. A small temperature and relative humidity data logger is placed between the pillows small white box, central. U.S. astronauts living and working aboard the International Space Station are going to receive a newly developed Vegetable Production System VEGGIE. VEGGIE is set to launch aboard SpaceX's Dragon capsule on NASA's third Commercial Resupply Services mission targeted to launch Dec. 9 from Space Launch Complex 40 at Cape Canaveral Air Force Station in Florida. Photo credit: NASA/Gioia Massa
Advanced instrumentation for research in diving and hyperbaric medicine.
Sieber, Arne; L'Abbate, Antonio; Kuch, Benjamin; Wagner, Matthias; Benassi, Antonio; Passera, Mirko; Bedini, Remo
2010-01-01
Improving the safety of diving and increasing knowledge about the adaptation of the human body to underwater and hyperbaric environment require specifically developed underwater instrumentation for physiological measurements. In fact, none of the routine clinical devices for health control is suitable for in-water and/or under-pressure operation. The present paper addresses novel technological acquisitions and the development of three dedicated devices: * an underwater data logger for recording O2 saturation (reflective pulsoxymetry), two-channel ECG, depth and temperature; * an underwater blood pressure meter based on the oscillometric method; and * an underwater echography system. Moreover, examples of recordings are presented and discussed.
Morris, Gail; Conner, L Mike
2017-01-01
Global positioning system (GPS) technologies have improved the ability of researchers to monitor wildlife; however, use of these technologies is often limited by monetary costs. Some researchers have begun to use commercially available GPS loggers as a less expensive means of tracking wildlife, but data regarding performance of these devices are limited. We tested a commercially available GPS logger (i-gotU GT-120) by placing loggers at ground control points with locations known to < 30 cm. In a preliminary investigation, we collected locations every 15 minutes for several days to estimate location error (LE) and circular error probable (CEP). Using similar methods, we then investigated the influence of cover on LE, CEP, and fix success rate (FSR) by constructing cover over ground control points. We found mean LE was < 10 m and mean 50% CEP was < 7 m. FSR was not significantly influenced by cover and in all treatments remained near 100%. Cover had a minor but significant effect on LE. Denser cover was associated with higher mean LE, but the difference in LE between the no cover and highest cover treatments was only 2.2 m. Finally, the most commonly used commercially available devices provide a measure of estimated horizontal position error (EHPE) which potentially may be used to filter inaccurate locations. Using data combined from the preliminary and cover investigations, we modeled LE as a function of EHPE and number of satellites. We found support for use of both EHPE and number of satellites in predicting LE; however, use of EHPE to filter inaccurate locations resulted in the loss of many locations with low error in return for only modest improvements in LE. Even without filtering, the accuracy of the logger was likely sufficient for studies which can accept average location errors of approximately 10 m.
Understanding perceptions of stakeholder groups about Forestry Best Management Practices in Georgia.
Tumpach, Chantal; Dwivedi, Puneet; Izlar, Robert; Cook, Chase
2018-05-01
Forestry Best Management Practices (BMPs) are critical in ensuring sustainable forest management in the United States because of their effectiveness in protecting water quality, reducing soil erosion, maintaining riparian habitat, and sustaining site productivity. The success of forestry BMPs depends heavily on coordination among primary stakeholder groups. It is important to understand perceptions of such groups for a successful forest policy formulation. We used the SWOT-AHP (Strengths, Weaknesses, Opportunities, and Threats analysis with the Analytical Hierarchy Process) framework to assess perceptions of three stakeholder groups (loggers, landowners, agency foresters) about forestry BMPs in Georgia, the largest roundwood producing state in the United States. The agency and logger stakeholder groups gave the highest priority to improved reputation under the strength category, whereas the landowner stakeholder group perceived sustainable forestry as the highest priority under the same category. Lack of landowner education was the highest priority under the weakness category for landowner and agency stakeholder groups, whereas the logger stakeholder group selected lack of trained personnel as the highest priority under the same category. Agency and landowner stakeholder groups gave the highest priority to training and education while loggers indicated maintenance of forest-based environmental benefits as their highest priority under the opportunity category. Finally, landowners and agency stakeholder groups perceived more regulations and restrictions as most significant in the threat category whereas the logger stakeholder group was most concerned about the insufficient accounting of cost sharing under the same category. Overall, selected stakeholder groups recognize the importance of forestry BMPs and had positive perceptions about them. A collaborative approach based on continuous feedback can streamline expectations of stakeholder groups about forestry BMPs in Georgia and several other states that are interested in maintaining high compliance rate of forestry BMPs for ensuring sustainable forest management. Copyright © 2018 Elsevier Ltd. All rights reserved.
Soil surface temperatures reveal moderation of the urban heat island effect by trees and shrubs
Edmondson, J. L.; Stott, I.; Davies, Z. G.; Gaston, K. J.; Leake, J. R.
2016-01-01
Urban areas are major contributors to air pollution and climate change, causing impacts on human health that are amplified by the microclimatological effects of buildings and grey infrastructure through the urban heat island (UHI) effect. Urban greenspaces may be important in reducing surface temperature extremes, but their effects have not been investigated at a city-wide scale. Across a mid-sized UK city we buried temperature loggers at the surface of greenspace soils at 100 sites, stratified by proximity to city centre, vegetation cover and land-use. Mean daily soil surface temperature over 11 months increased by 0.6 °C over the 5 km from the city outskirts to the centre. Trees and shrubs in non-domestic greenspace reduced mean maximum daily soil surface temperatures in the summer by 5.7 °C compared to herbaceous vegetation, but tended to maintain slightly higher temperatures in winter. Trees in domestic gardens, which tend to be smaller, were less effective at reducing summer soil surface temperatures. Our findings reveal that the UHI effects soil temperatures at a city-wide scale, and that in their moderating urban soil surface temperature extremes, trees and shrubs may help to reduce the adverse impacts of urbanization on microclimate, soil processes and human health. PMID:27641002
Soil surface temperatures reveal moderation of the urban heat island effect by trees and shrubs.
Edmondson, J L; Stott, I; Davies, Z G; Gaston, K J; Leake, J R
2016-09-19
Urban areas are major contributors to air pollution and climate change, causing impacts on human health that are amplified by the microclimatological effects of buildings and grey infrastructure through the urban heat island (UHI) effect. Urban greenspaces may be important in reducing surface temperature extremes, but their effects have not been investigated at a city-wide scale. Across a mid-sized UK city we buried temperature loggers at the surface of greenspace soils at 100 sites, stratified by proximity to city centre, vegetation cover and land-use. Mean daily soil surface temperature over 11 months increased by 0.6 °C over the 5 km from the city outskirts to the centre. Trees and shrubs in non-domestic greenspace reduced mean maximum daily soil surface temperatures in the summer by 5.7 °C compared to herbaceous vegetation, but tended to maintain slightly higher temperatures in winter. Trees in domestic gardens, which tend to be smaller, were less effective at reducing summer soil surface temperatures. Our findings reveal that the UHI effects soil temperatures at a city-wide scale, and that in their moderating urban soil surface temperature extremes, trees and shrubs may help to reduce the adverse impacts of urbanization on microclimate, soil processes and human health.
Soil surface temperatures reveal moderation of the urban heat island effect by trees and shrubs
NASA Astrophysics Data System (ADS)
Edmondson, J. L.; Stott, I.; Davies, Z. G.; Gaston, K. J.; Leake, J. R.
2016-09-01
Urban areas are major contributors to air pollution and climate change, causing impacts on human health that are amplified by the microclimatological effects of buildings and grey infrastructure through the urban heat island (UHI) effect. Urban greenspaces may be important in reducing surface temperature extremes, but their effects have not been investigated at a city-wide scale. Across a mid-sized UK city we buried temperature loggers at the surface of greenspace soils at 100 sites, stratified by proximity to city centre, vegetation cover and land-use. Mean daily soil surface temperature over 11 months increased by 0.6 °C over the 5 km from the city outskirts to the centre. Trees and shrubs in non-domestic greenspace reduced mean maximum daily soil surface temperatures in the summer by 5.7 °C compared to herbaceous vegetation, but tended to maintain slightly higher temperatures in winter. Trees in domestic gardens, which tend to be smaller, were less effective at reducing summer soil surface temperatures. Our findings reveal that the UHI effects soil temperatures at a city-wide scale, and that in their moderating urban soil surface temperature extremes, trees and shrubs may help to reduce the adverse impacts of urbanization on microclimate, soil processes and human health.
Ground-based thermal imaging of stream surface temperatures: Technique and evaluation
Bonar, Scott A.; Petre, Sally J.
2015-01-01
We evaluated a ground-based handheld thermal imaging system for measuring water temperatures using data from eight southwestern USA streams and rivers. We found handheld thermal imagers could provide considerably more spatial information on water temperature (for our unit one image = 19,600 individual temperature measurements) than traditional methods could supply without a prohibitive amount of effort. Furthermore, they could provide measurements of stream surface temperature almost instantaneously compared with most traditional handheld thermometers (e.g., >20 s/reading). Spatial temperature analysis is important for measurement of subtle temperature differences across waterways, and identification of warm and cold groundwater inputs. Handheld thermal imaging is less expensive and equipment intensive than airborne thermal imaging methods and is useful under riparian canopies. Disadvantages of handheld thermal imagers include their current higher expense than thermometers, their susceptibility to interference when used incorrectly, and their slightly lower accuracy than traditional temperature measurement methods. Thermal imagers can only measure surface temperature, but this usually corresponds to subsurface temperatures in well-mixed streams and rivers. Using thermal imaging in select applications, such as where spatial investigations of water temperature are needed, or in conjunction with stationary temperature data loggers or handheld electronic or liquid-in-glass thermometers to characterize stream temperatures by both time and space, could provide valuable information on stream temperature dynamics. These tools will become increasingly important to fisheries biologists as costs continue to decline.
An Analysis of Mimosa pudica Leaves Movement by Using LoggerPro Software
NASA Astrophysics Data System (ADS)
Sugito; Susilo; Handayani, L.; Marwoto, P.
2016-08-01
The unique phenomena of Mimosa pudica are the closing and opening movements of its leaves when they got a stimulus. By using certain software, these movements can be drawn into graphic that can be analysed. The LoggerPro provides facilities needed to analyse recorded videos of the plant's reaction to stimulus. Then, through the resulted graph, analysis of some variables can be carried out. The result showed that the plant's movement fits an equation of y = mx + c.
Fine Scale Baleen Whale Behavior Observed Via Tagging Over Daily Time Scales
2014-09-30
During late fall 2013 and winter 2014, I built a data logger for the optical plankton counter ( OPC ) to facilitate its continued use on the NOAA Ship...Gordon Gunter. This ship has very long (> 5 km) of conducting sea cable, and we had communication issues with the OPC with the manufacturers...telemetry system over this long sea cable. To solve this problem, I adapted an existing data logger to provide power and log data from the OPC locally on
Sitting in the sun: Nest microhabitat affects incubation temperatures in seabirds.
Hart, Lorinda A; Downs, Colleen T; Brown, Mark
2016-08-01
During incubation parent birds are committed to a nest site and endure a range of ambient conditions while regulating egg temperatures. Using artificial eggs containing temperature loggers alongside ambient temperature (Ta) controls, incubation profiles were determined for four tropical seabird species at different nest site locations. Camera traps were used for ad-hoc behavioural incubation observations. Eggs experienced a range of temperatures during incubation and varied significantly between species and in some cases between different microhabitats within a species. Such variation has important consequences in the phenotypic expression of both physical and physiological traits of chicks, and ultimately species fitness. Exposed nest sites were more strongly correlated to Tas. Camera traps highlighted different incubation strategies employed by these species that could be related to trade-offs in predator defence, feeding habits, and temperature regulation of eggs. This study provides evidence that species with similar breeding habits could be affected by environmental stressors in similar ways and that the differences shown in nest site selection could negate some of these effects. We propose that habitats providing suitable nest microclimates will become increasingly important for the successful breeding of seabird species, particularly under predicted climate change scenarios. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cox, Marisa H.; Hatch, Christine
2003-01-01
Temperature, water level elevation, stage height, and river discharge data for this report were collected in and adjacent to the Russian River from Hopland to Guerneville, CA over a four-year period from 1998 to 2002 to establish baselines for long-term water quality, water supply and habitat. Data files presented in this report were collected by the USGS and the Sonoma County Water Agency's Engineering Resource and Planning, and Natural Resource Divisions. Temperature data were collected in single-channel submersible microloggers or temperature data were collected simultaneously with water-elevation data in dual-channel down-hole data loggers. Stream stage and streamflow data were collected at USGS stream gaging stations located near Hopland, Healdsburg, and Guerneville over a 130 km reach of the Russian River. During the period of record stream flow ranged from 3 to 1458 m3/s. Stream temperature ranged from 8 to 29 oC while groundwater temperature ranged from 10 to 38 oC. Stream stage varied 5 m seasonly, while ground-water level varied 19 m over the same time scale.
Harrison, Brittany; Stern, Lily; Chung, Philip; Etemadi, Mozziyar; Kwiat, Dillon; Roy, Shuvo; Harrison, Michael R; Martinez-Ferro, Marcelo
2016-04-01
Patient compliance is a crucial determinant of outcomes in treatments involving medical braces, such as dynamic compression therapy for pectus carinatum (PC). We performed a pilot study to assess a novel, wireless, real-time monitoring system (MyPectus) to address noncompliance. Eight patients (10-16years old) with moderately severe PC deformities underwent bracing. Each patient received a data logger device inserted in the compression brace to sense temperature and pressure. The data were transmitted via Bluetooth 4.0 to an iOS smartphone app, then synced to cloud-based storage, and presented to the clinician on a web-based dashboard. Patients received points for brace usage on the app throughout the 4-week study, and completed a survey to capture patient-reported usage patterns. In all 8 patients, the data logger sensed and recorded data, which connected through all MyPectus system components. There were occasional lapses in data collection because of technical difficulties, such as limited storage capacity. Patients reported positive feedback regarding points. The components of the MyPectus system recorded, stored, and provided data to patients and clinicians. The MyPectus system will inform clinicians about issues related to noncompliance: discrepancy between patient-reported and sensor-reported data regarding brace usage; real-time, actionable information; and patient motivation. Copyright © 2015 Elsevier Inc. All rights reserved.
Ortiz-Tudela, Elisabet; Martinez-Nicolas, Antonio; Albares, Javier; Segarra, Francesc; Campos, Manuel; Estivill, Eduard; Rol, Maria Angeles; Madrid, Juan Antonio
2014-03-14
An integrated variable based on the combination of wrist Temperature, motor Activity and body Position (TAP) was previously developed at our laboratory to evaluate the functioning of the circadian system and sleep-wake rhythm under ambulatory conditions. However, the reliability of TAP needed to be validated with polysomnography (PSG). 22 subjects suffering from sleep disorders were monitored for one night with a temperature sensor (iButton), an actimeter (HOBO) and exploratory PSG. Mean waveforms, sensitivity (SE), specificity (SP), agreement rates (AR) and comparisons between TAP and sleep stages were studied. The TAP variable was optimized for SE, SP and AR with respect to each individual variable (SE: 92%; SP: 78%; AR: 86%). These results improved upon estimates previously published for actigraphy. Furthermore, TAP values tended to decrease as sleep depth increased, reaching the lowest point at phase 3. Finally, TAP estimates for sleep latency (SL: 37±9 min), total sleep time (TST: 367±13 min), sleep efficiency (SE: 86.8±1.9%) and number of awakenings (NA>5 min: 3.3±.4) were not significantly different from those obtained with PSG (SL: 29±4 min; SE: 89.9±1.8%; NA>5 min: 2.3±.4), despite the heterogeneity of the sleep pathologies monitored. The TAP variable is a novel measurement for evaluating circadian system status and sleep-wake rhythms with a level of reliability better to that of actigraphy. Furthermore, it allows the evaluation of a patient's sleep-wake rhythm in his/her normal home environment, and at a much lower cost than PSG. Future studies in specific pathologies would verify the relevance of TAP in those conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
George, W D; Godfrey, R W; Ketring, R C; Vinson, M C; Willard, S T
2014-11-01
Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.
Taylor, Gregory T.; Ackerman, Joshua T.; Shaffer, Scott A.
2018-01-01
Egg turning behavior is an important determinant of egg hatchability, but it remains relatively understudied. Here, we examined egg turning rates and egg temperatures in Forster’s terns (Sterna forsteri). We used artificial eggs containing a data logger with a 3-D accelerometer, a magnetometer, and a temperature thermistor to monitor parental incubation behavior of 131 tern nests. Overall, adults turned their eggs an average (±SD) of 3.8 ± 0.8 turns h-1, which is nearly two times higher than that of other seabirds. Egg turning rates increased with nest initiation date. We also examined egg turning rates and egg temperatures in relation to egg mercury contamination. Mercury contamination has been shown to be associated with reduced egg hatchability, and we hypothesized that mercury may decrease egg hatchability via altered egg turning behavior by parents. Despite the high variability in egg turning rates among individuals, the rate of egg turning was not related to mercury concentrations in sibling eggs. These findings highlight the need for further study concerning the potential determinants of egg turning behavior.
Understanding lizard's microhabitat use based on a mechanistic model of behavioral thermoregulation
NASA Astrophysics Data System (ADS)
Fei, Teng; Venus, Valentijn; Toxopeus, Bert; Skidmore, Andrew K.; Schlerf, Martin; Liu, Yaolin; van Overdijk, Sjef; Bian, Meng
2008-12-01
Lizards are an "excellent group of organisms" to examine the habitat and microhabitat use mainly because their ecology and physiology is well studied. Due to their behavioral body temperature regulation, the thermal environment is especially linked with their habitat use. In this study, for mapping and understanding lizard's distribution at microhabitat scale, an individual of Timon Lepidus was kept and monitored in a terrarium (245×120×115cm) in which sand, rocks, burrows, hatching chambers, UV-lamps, fog generators and heating devices were placed to simulate its natural habitat. Optical cameras, thermal cameras and other data loggers were fixed and recording the lizard's body temperature, ground surface temperature, air temperature, radiation and other important environmental parameters. By analysis the data collected, we propose a Cellular Automata (CA) model by which the movement of lizards is simulated and translated into their distribution. This paper explores the capabilities of applying GIS techniques to thermoregulatory activity studies in a microhabitat-scale. We conclude that microhabitat use of lizards can be explained in some degree by the rule based CA model.
Taylor, Gregory T; Ackerman, Joshua T; Shaffer, Scott A
2018-01-01
Egg turning behavior is an important determinant of egg hatchability, but it remains relatively understudied. Here, we examined egg turning rates and egg temperatures in Forster's terns (Sterna forsteri). We used artificial eggs containing a data logger with a 3-D accelerometer, a magnetometer, and a temperature thermistor to monitor parental incubation behavior of 131 tern nests. Overall, adults turned their eggs an average (±SD) of 3.8 ± 0.8 turns h-1, which is nearly two times higher than that of other seabirds. Egg turning rates increased with nest initiation date. We also examined egg turning rates and egg temperatures in relation to egg mercury contamination. Mercury contamination has been shown to be associated with reduced egg hatchability, and we hypothesized that mercury may decrease egg hatchability via altered egg turning behavior by parents. Despite the high variability in egg turning rates among individuals, the rate of egg turning was not related to mercury concentrations in sibling eggs. These findings highlight the need for further study concerning the potential determinants of egg turning behavior.
Ackerman, Joshua T.; Shaffer, Scott A.
2018-01-01
Egg turning behavior is an important determinant of egg hatchability, but it remains relatively understudied. Here, we examined egg turning rates and egg temperatures in Forster’s terns (Sterna forsteri). We used artificial eggs containing a data logger with a 3-D accelerometer, a magnetometer, and a temperature thermistor to monitor parental incubation behavior of 131 tern nests. Overall, adults turned their eggs an average (±SD) of 3.8 ± 0.8 turns h-1, which is nearly two times higher than that of other seabirds. Egg turning rates increased with nest initiation date. We also examined egg turning rates and egg temperatures in relation to egg mercury contamination. Mercury contamination has been shown to be associated with reduced egg hatchability, and we hypothesized that mercury may decrease egg hatchability via altered egg turning behavior by parents. Despite the high variability in egg turning rates among individuals, the rate of egg turning was not related to mercury concentrations in sibling eggs. These findings highlight the need for further study concerning the potential determinants of egg turning behavior. PMID:29447185
Wireless monitoring of highways
NASA Astrophysics Data System (ADS)
Bennett, Richard; Hayes-Gill, Barrie; Crowe, John A.; Armitage, Robert; Rodgers, Dale; Hendroff, Adrian
1999-05-01
Electronic hardware has been developed to telemetrically transmit temperature and strain measurements from within a public highway in the UK. These measurements provide an important health check for monitoring fatigue damage in pavements. Previous attempts at measuring strain and temperature have required lengths of cable to be installed in the highway. The installation of these cables is both expensive and damaging to the pavement and provides potentially unreliable electrical connections. The new systems consist of a retrofitted instrumented asphalt core which is bonded into the pavement structure. The core contains all the electronics necessary to record two temperatures and two strains. An analogue front end provides signal conditioning which is digitized and passed to microcontroller for endcoding. From there the data is transmitted via a low power radio link to a receiver and data logger positioned by the side of the road. The system has an in-situ operating life of 6 months on AA alkaline batteries. Results are presented of power management and fault tolerant radio protocol techniques, long term temperature variations, dynamic strain measurements within the highway, and RF transmission capabilities through a layer of asphalt.
NASA Astrophysics Data System (ADS)
Weiss, S. B.; Bunn, A. G.; Tran, T. J.; Bruening, J. M.; Salzer, M. W.; Hughes, M. K.
2016-12-01
The interpretation of ring-width patterns in high elevation Great Basin bristlecone pine is hampered by the presence of sharp ecophysiological gradients that can lead to mixed growth signals depending on topographic setting of individual trees. We have identified a temperature threshold near the upper forest border above which trees are limited more strongly by temperature, and below which trees tend to be moisture limited. We combined temperature loggers and GIS modeling at a scale of tens of meters to examine trees with different limiting factors. We found that the dual-signal patterns in radial growth can be partially explained by the topoclimate setting of individual trees, with trees in locations where growing season mean temperatures below about 7.4°C to 8°C were more strongly associated with temperature variability than with moisture availability. Using this threshold we show that it is possible to build both temperature and drought reconstructions over the common era from bristlecone pine near the alpine treeline. While our findings might allow for a better physiological understanding of bristlecone pine growth, they also raise questions about the interpretation of temperature reconstructions given the threshold nature of the growth response and the dynamic nature of the treeline ecotone over past millennia.
A portable data-logging system for industrial hygiene personal chlorine monitoring.
Langhorst, M L; Illes, S P
1986-02-01
The combination of suitable portable sensors or instruments with small microprocessor-based data-logger units has made it possible to obtain detailed monitoring data for many health and environmental applications. Following data acquisition in field use, the logged data may be transferred to a desk-top personal computer for complete flexibility in manipulation of data and formating of results. A system has been assembled from commercial components and demonstrated for chlorine personal monitoring applications. The system consists of personal chlorine sensors, a Metrosonics data-logger and reader unit, and an Apple II Plus personal computer. The computer software was developed to handle sensor calibration, data evaluation and reduction, report formating and long-term storage of raw data on a disk. This system makes it possible to generate time-concentration profiles, evaluate dose above a threshold, quantitate short-term excursions and summarize time-weighted average (TWA) results. Field data from plant trials demonstrated feasibility of use, ruggedness and reliability. No significant differences were found between the time-weighted average chlorine concentrations determined by the sensor/logger system and two other methods: the sulfamic acid bubbler reference method and the 3M Poroplastic diffusional dosimeter. The sensor/data-logger system, however, provided far more information than the other two methods in terms of peak excursions, TWAs and exposure doses. For industrial hygiene applications, the system allows better definition of employee exposures, particularly for chemicals with acute as well as chronic health effects.(ABSTRACT TRUNCATED AT 250 WORDS)
Open Source Hardware for DIY Environmental Sensing
NASA Astrophysics Data System (ADS)
Aufdenkampe, A. K.; Hicks, S. D.; Damiano, S. G.; Montgomery, D. S.
2014-12-01
The Arduino open source electronics platform has been very popular within the DIY (Do It Yourself) community for several years, and it is now providing environmental science researchers with an inexpensive alternative to commercial data logging and transmission hardware. Here we present the designs for our latest series of custom Arduino-based dataloggers, which include wireless communication options like self-meshing radio networks and cellular phone modules. The main Arduino board uses a custom interface board to connect to various research-grade sensors to take readings of turbidity, dissolved oxygen, water depth and conductivity, soil moisture, solar radiation, and other parameters. Sensors with SDI-12 communications can be directly interfaced to the logger using our open Arduino-SDI-12 software library (https://github.com/StroudCenter/Arduino-SDI-12). Different deployment options are shown, like rugged enclosures to house the loggers and rigs for mounting the sensors in both fresh water and marine environments. After the data has been collected and transmitted by the logger, the data is received by a mySQL-PHP stack running on a web server that can be accessed from anywhere in the world. Once there, the data can be visualized on web pages or served though REST requests and Water One Flow (WOF) services. Since one of the main benefits of using open source hardware is the easy collaboration between users, we are introducing a new web platform for discussion and sharing of ideas and plans for hardware and software designs used with DIY environmental sensors and data loggers.
Romón, Pedro; Aparicio, Domitila; Palacios, Francisco; Iturrondobeitia, Juan Carlos; Hance, Thierry
2017-01-01
Abstract Concentrations of four monoterpenes were determined in needles of Pinus radiata (D.Don) (Pinales: Pinaceae) trees that were attacked or nonattacked by Tomicus piniperda (L.) (Coleoptera: Scolytinae). Compounds were identified and quantified by gas chromatography–mass spectrometry. The mean ambient temperature was obtained using climate-recording data loggers. The effect of limonene on field aggregation was also evaluated at three limonene release rates using Lindgren attractant-baited traps and trap logs. Attacked trees produced less α-pinene in March, July, and November than nonattacked trees, less β-pinene in July and November, and less limonene from May to November. Limonene reduced the attraction of T. piniperda to attractant-baited traps and trap logs. Results were linked to better responses to high temperatures, with respect to terpene contents, by the nonattacked trees after the spring attack. PMID:29117373
Hepatitis B vaccine freezing in the Indonesian cold chain: evidence and solutions.
Nelson, Carib M; Wibisono, Hariadi; Purwanto, Hary; Mansyur, Isa; Moniaga, Vanda; Widjaya, Anton
2004-02-01
To document and characterize freezing temperatures in the Indonesian vaccine cold chain and to evaluate the feasibility of changes designed to reduce the occurrence of freezing. Data loggers were used to measure temperatures of shipments of hepatitis B vaccine from manufacturer to point of use. Baseline conditions and three intervention phases were monitored. During each of the intervention phases, vaccines were removed progressively from the standard 2-8 degrees C cold chain. Freezing temperatures were recorded in 75% of baseline shipments. The highest rates of freezing occurred during transport from province to district, storage in district-level ice-lined refrigerators, and storage in refrigerators in health centres. Interventions reduced freezing, without excessive heat exposure. Inadvertent freezing of freeze-sensitive vaccines is widespread in Indonesia. Simple strategies exist to reduce freezing - for example, selective transport and storage of vaccines at ambient temperatures. The use of vaccine vial monitors reduces the risk associated with heat-damaged vaccines in these scenarios. Policy changes that allow limited storage of freeze-sensitive vaccines at temperatures >2-8 degrees C would enable flexible vaccine distribution strategies that could reduce vaccine freezing, reduce costs, and increase capacity.
Monitoring of soil and air-rock temperatures in the Western Massif of the Picos de Europa (Spain)
NASA Astrophysics Data System (ADS)
Ruiz-Fernández, Jesús; Vieira, Gonçalo; García, Cristina
2013-04-01
In this paper we study the ground thermal regime and air-rock interface in the Western Massif of the Picos de Europa (Cantabrian Range, Spain). This calcareous massif is highly affected by karstification processes. Quaternary glaciers, fluvio-torrential processes and present-day periglacial processes also contribute to explain the landforms present in this massif. Up to 9 dataloggers were installed during 6 years in different sites in terms of altitude, orientation, slope and geomorpolohical setting recording temperatures every two hours. The number of freeze-thaw cycles in the soil(between 0 and 16) was controlled by the depth of the snow cover. The temperatures in the interface rock-air showed between 30-60 cycles, reaching 119 and 130 during the year 2007-2008. Extreme minimum temperatures in the soil oscillate between 0.3 and -6.3, while in the rocky walls the loggers recorded temperatures between -7.3 and -14.3°C. Monitoring of soil temperatures around the ice patch - the only one in the massif today - resulted in slightly negative mean annual temperatures. These conditions may reveal the existence of sporadic permafrost on debris that cover the ice patch. Both the buried ice and the permafrost are in disequilibrium with the current environmental conditions of the massif.
MacRae, Braid A; Rossi, Rene Michel; Psikuta, Agnes; Spengler, Christina M; Annaheim, Simon
2018-06-05
Locally increasing evaporative resistance is one mechanism by which contact skin temperature (Tsk) sensors and their attachments may disturb the temperature of the skin site being measured. We aimed to determine the extent to which an obstruction of evaporation affects local Tsk during exercise-induced sweating and how this compares to the Tsk measured using a conventional contact Tsk sensor. Twelve adult males each completed one experimental session (~24°C, ~46 % relative humidity; RH) involving seated rest and exercise (cycle ergometer). Air velocity was ~0.5 m·s-1 during rest and ~1 m·s-1 during exercise. Tsk of the right posterolateral forearm was measured using fine-wire thermocouples (0.125 mm diameter; chosen for minimal sensor-related disturbance) under two concurrent experimental conditions: uncovered or directly covered by a moisture-impermeable matte-black aluminium foil (thickness 0.08 mm, area 15 mm x 22 mm). The adjacent Tsk was also measured using an iButton attached with a nonwoven medical tape. Changes in next-to-skin absolute vapour pressure were used to estimate the onset of sweating. During exercise, covered thermocouple temperatures were consistently warmer than those uncovered. These differences were small before the onset of sweating (0.1°C, p=0.16), but increased thereafter (0.6 and 1.0°C by minutes 15 and 30 of exercise, respectively; p≤0.03). For change scores from baseline rest, the iButton-measured Tsk was as much as 0.7°C warmer than uncovered and -0.4°C cooler than covered thermocouples during sweating, but differences were not statistically supported and with wide 95% limits of agreement (up to ±3.1°C). When delineated, a small obstruction of evaporation itself caused an overestimation of Tsk during exercise although, while demonstrable, these effects were less clear in the context of using a conventional contact Tsk sensor and attachment. © 2018 Institute of Physics and Engineering in Medicine.
Experimental urban heat island research of Norilsk city in northern Russia in the polar night
NASA Astrophysics Data System (ADS)
Varentsov, Mikhail; Konstantinov, Pavel; Repina, Irina; Samsonov, Timofey; Baklanov, Alexander
2014-05-01
Growing socioeconomic activity in Arctic zone and prospective of planning and building new settlements and cities in this region requires better understanding of the urban-caused microclimatic features and their behavior in the conditions of arctic and sub-arctic climate. The most important of these features is well-known urban heat island (UHI) effect, because in high latitudes it could mitigate severe climatic conditions within urban areas and provide the economy of fuel for house heating. The UHI effect is quietly good investigated and described for the cities in low and moderate latitudes (Oke, 1987), but there is significant lack of knowledge about UHI of the cities over the Polar Circle and especially about its behavior during the polar night, while anthropogenic heat is the only source of energy to form heat island. In this study, we consider the results of experimental research of the UHI of Norilsk - the second biggest city over the Polar Circle, which were obtained during the expedition of Russian Geographic Society in December 2013, practically around the middle of the polar night. Field measurements in Norilsk included installation of three automatic weather stations (AWS) and the net of small temperature sensors (iButton) in the city and surrounding landscape and also car-based temperature sounding of the city with AWS. The influence of the relief and stratification was filtered by using the data of MTP-5 microwave temperature profiler. Analysis of the collected data showed the existence of significant UHI with the difference between city center and surrounding landscape up to 6 °C. The dependence of UHI power and shape on the synoptic conditions were analyzed for several typical synoptic situations, which were observed during the expedition, and the negative correlation of the UHI power with air temperature was determined. The reported study was supported by Russian Geographic Society, research projects No. 69/2013-H7 and 27/2013-H3. References: 1.Oke, Timothy R. Boundary layer climates - 2nd ed. Publisher, London: Routledge. 1987
Predicting the Spatial Variability of Fuel Moisture Content in Mountainous Eucalyptus Forests
NASA Astrophysics Data System (ADS)
Sheridan, G. J.; Nyman, P.; Lane, P. N. J.; Metzen, D.
2014-12-01
In steep mountainous landscapes, topographic aspect can play a significant role in small-scale (ie. scales in the order of 10's ha) variability in surface fuel moisture. Experimental sites for monitoring microclimate variables and moisture content in litter and in near-surface soils were established at a control site and on four contrasting aspects (north, south, east and west) in southeast Australia. At each of the four microclimate sites sensors are arranged to measure the soil moisture (2 replicates), surface fuel moisture at 2.5cm depth (12 replicates), precipitation throughfall (3 replicates), radiation (3 replicates), and screen level relative humidity, air temperature, leaf wetness, and wind speed (1 replicate of each). Temperature and relative humidity are also measured within the dead fine surface fuel using Ibutton's (4 replicates). All measurements are logged continuously at 15 min intervals. The moisture content of the surface fuel is estimated using a novel method involving high-replication of low-cost continuous soil moisture sensors placed at the centre of a 5cm deep sample of fine dead surface fuel, referred to here as "litter-packs". The litter-packs were constructed from fuels collected from the area surrounding the microclimate site. The initial results show the moisture regime on the forest floor was highly sensitive to the incoming shortwave radiation, which was up to 6 times higher in the north-facing (equatorial) slopes due to slope orientation and the sparse vegetation compared to vegetation on the south-facing (polar facing) slopes. Differences in shortwave radiation resulted in peak temperatures within the litter that were up to 2 times higher on the equatorial-facing site than those on the polar-facing site. For instance, on a day in November 2013 with maximum open air temperature of 35o C, the temperatures within the litter layer at the north-facing and south-facing sites were 54o C and 32o C, respectively, despite air temperature at the two sites differing by less than 2o C. The minimum gravimetric water content in the litter layer on the same day was 21% on the equatorial-facing slope and 85% on the polar-facing slope. The experimental data has been used to calibrate a topographic downscaling algorithm, yielding estimates of surface fuel moisture at 20m resolution.
NASA Astrophysics Data System (ADS)
Soto-López, Carlos D.; Meixner, Thomas; Ferré, Ty P. A.
2011-12-01
From its inception in the mid-1960s, the use of temperature time series (thermographs) to estimate vertical fluxes has found increasing use in the hydrologic community. Beginning in 2000, researchers have examined the impacts of measurement and parameter uncertainty on the estimates of vertical fluxes. To date, the effects of temperature measurement discretization (resolution), a characteristic of all digital temperature loggers, on the determination of vertical fluxes has not been considered. In this technical note we expand the analysis of recently published work to include the effects of temperature measurement resolution on estimates of vertical fluxes using temperature amplitude and phase shift information. We show that errors in thermal front velocity estimation introduced by discretizing thermographs differ when amplitude or phase shift data are used to estimate vertical fluxes. We also show that under similar circumstances sensor resolution limits the range over which vertical velocities are accurately reproduced more than uncertainty in temperature measurements, uncertainty in sensor separation distance, and uncertainty in the thermal diffusivity combined. These effects represent the baseline error present and thus the best-case scenario when discrete temperature measurements are used to infer vertical fluxes. The errors associated with measurement resolution can be minimized by using the highest-resolution sensors available. But thoughtful experimental design could allow users to select the most cost-effective temperature sensors to fit their measurement needs.
Hill, T M; Bateman, H G; Suarez-Mena, F X; Dennis, T S; Schlotterbeck, R L
2016-11-01
Extensive measurements of calf body temperature are limited in the literature. In this study, body temperatures were collected by taping a data logger to the skin over the tail vein opposing the rectum of Holstein calves between 4 and 60d of age during 3 different periods of the summer and fall. The summer period was separated into moderate (21-33°C average low to high) and hot (25-37°C) periods, whereas the fall exhibited cool (11-19°C) ambient temperatures. Tail temperatures were compared in a mixed model ANOVA using ambient temperature, age of calf, and time of day (10-min increments) as fixed effects and calf as a random effect. Measures within calf were modeled as repeated effects of type autoregressive 1. Calf temperature increased 0.0325°C (±0.00035) per 1°C increase in ambient temperature. Body temperature varied in a distinct, diurnal pattern with time of day, with body temperatures being lowest around 0800h and highest between 1700 and 2200h. During periods of hot weather, the highest calf temperature was later in the day (~2200h). Calf minimum, maximum, and average body temperatures were all higher in hot than in moderate periods and higher in moderate than in cool periods. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
A comparison in Colorado of three methods to monitor breeding amphibians
Corn, P.S.; Muths, E.; Iko, W.M.
2000-01-01
We surveyed amphibians at 4 montane and 2 plains lentic sites in northern Colorado using 3 techniques: standardized call surveys, automated recording devices (frog-loggers), and intensive surveys including capture-recapture techniques. Amphibians were observed at 5 sites. Species richness varied from 0 to 4 species at each site. Richness scores, the sums of species richness among sites, were similar among methods: 8 for call surveys, 10 for frog-loggers, and 11 for intensive surveys (9 if the non-vocal salamander Ambystoma tigrinum is excluded). The frog-logger at 1 site recorded Spea bombifrons which was not active during the times when call and intensive surveys were conducted. Relative abundance scores from call surveys failed to reflect a relatively large population of Bufo woodhousii at 1 site and only weakly differentiated among different-sized populations of Pseudacris maculata at 3 other sites. For extensive applications, call surveys have the lowest costs and fewest requirements for highly trained personnel. However, for a variety of reasons, call surveys cannot be used with equal effectiveness in all parts of North America.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HUBER, J.H.
An Enraf Densitometer is installed on tank 241-AY-102. The Densitometer will frequently be tasked to obtain and log density profiles. The activity can be effected a number of ways. Enraf Incorporated provides a software package called ''Logger18'' to its customers for the purpose of in-shop testing of their gauges. Logger18 is capable of accepting an input file which can direct the gauge to obtain a density profile for a given tank level and bottom limit. Logger18 is a complex, DOS based program which will require trained technicians and/or tank farm entries to obtain the data. ALARA considerations have prompted themore » development of a more user-friendly, computer-based interface to the Enraf densitometers. This document records the plan by which this new Enraf data acquisition software will be developed, reviewed, verified, and released. This plan applies to the development and implementation of a one-time-use software program, which will be called ''Enraf Control Panel.'' The software will be primarily used for remote operation of Enraf Densitometers for the purpose of obtaining and logging tank product density profiles.« less
Esteban, Nicole; Laloë, Jacques-Olivier; Mortimer, Jeanne A.; Guzman, Antenor N.; Hays, Graeme C.
2016-01-01
Sand temperatures at nest depths and implications for hatchling sex ratios of hawksbill turtles (Eretmochelys imbricata) and green turtles (Chelonia mydas) nesting in the Chagos Archipelago, Indian Ocean are reported and compared to similar measurements at rookeries in the Atlantic and Caribbean. During 2012–2014, temperature loggers were buried at depths and in beach zones representative of turtle nesting sites. Data collected for 12,546 days revealed seasonal and spatial patterns of sand temperature. Depth effects were minimal, perhaps modulated by shade from vegetation. Coolest and warmest temperatures were recorded in the sites heavily shaded in vegetation during the austral winter and in sites partially shaded in vegetation during summer respectively. Overall, sand temperatures were relatively cool during the nesting seasons of both species which would likely produce fairly balanced hatchling sex ratios of 53% and 63% male hatchlings, respectively, for hawksbill and green turtles. This result contrasts with the predominantly high female skew reported for offspring at most rookeries around the globe and highlights how local beach characteristics can drive incubation temperatures. Our evidence suggests that sites characterized by heavy shade associated with intact natural vegetation are likely to provide conditions suitable for male hatchling production in a warming world. PMID:26832230
NASA Astrophysics Data System (ADS)
Esteban, Nicole; Laloë, Jacques-Olivier; Mortimer, Jeanne A.; Guzman, Antenor N.; Hays, Graeme C.
2016-02-01
Sand temperatures at nest depths and implications for hatchling sex ratios of hawksbill turtles (Eretmochelys imbricata) and green turtles (Chelonia mydas) nesting in the Chagos Archipelago, Indian Ocean are reported and compared to similar measurements at rookeries in the Atlantic and Caribbean. During 2012-2014, temperature loggers were buried at depths and in beach zones representative of turtle nesting sites. Data collected for 12,546 days revealed seasonal and spatial patterns of sand temperature. Depth effects were minimal, perhaps modulated by shade from vegetation. Coolest and warmest temperatures were recorded in the sites heavily shaded in vegetation during the austral winter and in sites partially shaded in vegetation during summer respectively. Overall, sand temperatures were relatively cool during the nesting seasons of both species which would likely produce fairly balanced hatchling sex ratios of 53% and 63% male hatchlings, respectively, for hawksbill and green turtles. This result contrasts with the predominantly high female skew reported for offspring at most rookeries around the globe and highlights how local beach characteristics can drive incubation temperatures. Our evidence suggests that sites characterized by heavy shade associated with intact natural vegetation are likely to provide conditions suitable for male hatchling production in a warming world.
Reneerkens, Jeroen; Grond, Kirsten; Schekkerman, Hans; Tulp, Ingrid; Piersma, Theunis
2011-01-01
Birds breeding in cold environments regularly have to interrupt incubation to forage, causing a trade-off between two mutually exclusive behaviours. Earlier studies showed that uniparental Arctic sandpipers overall spend less time incubating their eggs than biparental species, but interspecific differences in size and ecology were potential confounding factors. This study reports on a within-species comparison of breeding schedules and metal egg temperatures in uni- and biparental sanderlings (Calidris alba) in Northeast Greenland in relation to ambient temperature. We recorded incubation schedules with nest temperature loggers in 34 sanderling clutches (13 uniparentals, 21 biparentals). The temperature of a metal egg placed within the clutch of 17 incubating birds (6 uniparentals, 9 biparentals) was measured as an indicator of the heat put into eggs. Recess frequency, recess duration and total recess time were higher in uniparentals than in biparentals and positively correlated with ambient temperatures in uniparentals only. Uniparental sanderlings maintained significantly higher metal egg temperatures during incubation than biparentals (1.4°C difference on average). Our results suggest that uniparental sanderlings compensate for the lower nest attendance, which may prolong the duration of the incubation period and negatively affect the condition of the hatchlings, by maintaining a higher heat flux into the eggs. PMID:21347377
Esteban, Nicole; Laloë, Jacques-Olivier; Mortimer, Jeanne A; Guzman, Antenor N; Hays, Graeme C
2016-02-02
Sand temperatures at nest depths and implications for hatchling sex ratios of hawksbill turtles (Eretmochelys imbricata) and green turtles (Chelonia mydas) nesting in the Chagos Archipelago, Indian Ocean are reported and compared to similar measurements at rookeries in the Atlantic and Caribbean. During 2012-2014, temperature loggers were buried at depths and in beach zones representative of turtle nesting sites. Data collected for 12,546 days revealed seasonal and spatial patterns of sand temperature. Depth effects were minimal, perhaps modulated by shade from vegetation. Coolest and warmest temperatures were recorded in the sites heavily shaded in vegetation during the austral winter and in sites partially shaded in vegetation during summer respectively. Overall, sand temperatures were relatively cool during the nesting seasons of both species which would likely produce fairly balanced hatchling sex ratios of 53% and 63% male hatchlings, respectively, for hawksbill and green turtles. This result contrasts with the predominantly high female skew reported for offspring at most rookeries around the globe and highlights how local beach characteristics can drive incubation temperatures. Our evidence suggests that sites characterized by heavy shade associated with intact natural vegetation are likely to provide conditions suitable for male hatchling production in a warming world.
Pierce, H.A.; Murray, J.B.
2009-01-01
The International Continental Scientific Drilling Program (ICDP) and the U.S. Geological Survey (USGS) drilled three core holes to a composite depth of 1766 m within the moat of the Chesapeake Bay impact structure. Core recovery rates from the drilling were high (??90%), but problems with core hole collapse limited the geophysical downhole logging to natural-gamma and temperature logs. To supplement the downhole logs, ??5% of the Chesapeake Bay impact structure cores was processed through the USGS GeoTek multisensor core logger (MSCL) located in Menlo Park, California. The measured physical properties included core thickness (cm), density (g cm-3), P-wave velocity (m s-1), P-wave amplitude (%), magnetic susceptibility (cgs), and resistivity (ohm-m). Fractional porosity was a secondary calculated property. The MSCL data-sampling interval for all core sections was 1 cm longitudinally. Photos of each MSCL sampled core section were imbedded with the physical property data for direct comparison. These data have been used in seismic, geologic, thermal history, magnetic, and gravity models of the Chesapeake Bay impact structure. Each physical property curve has a unique signature when viewed over the full depth of the Chesapeake Bay impact structure core holes. Variations in the measured properties reflect differences in pre-impact target-rock lithologies and spatial variations in impact-related deformation during late-stage crater collapse and ocean resurge. ?? 2009 The Geological Society of America.
Maloney, Shane K; Mitchell, Duncan; Blache, Dominique
2007-03-01
The degree of variability in the temperature difference between the brain and carotid arterial blood is greater than expected from the presumed tight coupling between brain heat production and brain blood flow. In animals with a carotid rete, some of that variability arises in the rete. Using thermometric data loggers in five sheep, we have measured the temperature of arterial blood before it enters the carotid rete and after it has perfused the carotid rete, as well as hypothalamic temperature, every 2 min for between 6 and 12 days. The sheep were conscious, unrestrained, and maintained at an ambient temperature of 20-22 degrees C. On average, carotid arterial blood and brain temperatures were the same, with a decrease in blood temperature of 0.35 degrees C across the rete and then an increase in temperature of the same magnitude between blood leaving the rete and the brain. Rete cooling of arterial blood took place at temperatures below the threshold for selective brain cooling. All of the variability in the temperature difference between carotid artery and brain was attributable statistically to variability in the temperature difference across the rete. The temperature difference between arterial blood leaving the rete and the brain varied from -0.1 to 0.9 degrees C. Some of this variability was related to a thermal inertia of the brain, but the majority we attribute to instability in the relationship between brain blood flow and brain heat production.
Coupled oscillators: interesting experiments for high school students
NASA Astrophysics Data System (ADS)
Kodejška, Č.; Lepil, O.; Sedláčková, H.
2018-07-01
This work deals with the experimental demonstration of coupled oscillators using simple tools in the form of mechanical coupled pendulums, magnetically coupled elastic strings or electromagnetic oscillators. For the evaluation of results the data logger Lab Quest Vernier and video analysis in the Tracker program were used. In the first part of this work, coupled mechanical oscillators of different types are shown and the data analysis by the Tracker or Vernier Logger Pro programs. The second part describes a measurement using two LC circuits with inductively or capacitive coupled electromagnetic oscillators and the obtained experimental results.
The results of studies of temperature fields in the Elbrus volcanic center
NASA Astrophysics Data System (ADS)
Likhodeev, D. V.
2012-04-01
The results of theoretical and experimental studies on thermal processes in the Elbrus volcanic center and adjacent territories are presented. Distributed temperature measurements on the Elbrus volcano and in the Northern-Caucasus Geophysical Observatory have been performed. Series of measurements were also performed with an aid from autonomous systems for temperature («High Capacity Temperature Loggers iButton» and «Rejim-avtomat-termo-10-100») monitoring in the mountain lake located near the Maloye Azau glacier. The comparative analysis of the results for different years is provided. On the basis of the Geophysical Observatory in Northern Caucasus, in the laboratory located some 20 km from the Elbrus volcano in the tunnel at a depth of 4 km the array of temperature sensors has been deployed. Results of continuous observations over variations of underground temperatures, including pin-point measurements in the vicinity of sources of carbonaceous mineral waters are presented and discussed. Based on the results of temperature measurements in the 180-meter deep borehole drilled in the ice cap on the western plateau of the Elbrus volcano the theoretical estimations of possible deep temperatures and heat flux values have been obtained and corresponded to the proposed location of the peripheral magma chamber. Thus, the original scientific results provide significant extension to our knowledge on possible resumption of volcanic activity in the vicinity of Mount Elbrus.
Le Goff, Thierry; Braven, Jim; Ebdon, Les; Chilcottt, Neil P; Scholefield, David; Wood, John W
2002-04-01
A field evaluation of a novel nitrate-ion selective electrode (ISE) was undertaken by continuous immersion over a period of 5 months in agricultural drainage weirs. The nitrate sensor N,N,N-triallyl leucine betaine was covalently attached to polystyrene-block-polybutadiene-block-polystyrene (SBS) using a free radical initiated co-polymerisation, to produce a rubbery membrane which was incorporated into a commercially available electrode body. A measurement unit was constructed comprising the nitrate-ISEs, a reference electrode and a temperature probe connected through a pre-amplifier to a data-logger and battery supply. A temperature correction algorithm was developed to accomodate the temperature changes encountered in the drainage weirs. The nitrate results obtained with the ISEs at hourly intervals compared very favourably (R2 = 0.99) with those obtained with laboratory automated chemical determinations made on contemporaneous samples of drainage in a concentration range 0.47-16 ppm nitrate-N. The ISEs did not require re-calibration and no deterioration in performance or fouling of the membrane surface was observed over four months of deployment.
Task-dependent cold stress during expeditions in Antarctic environments.
Morris, Drew M; Pilcher, June J; Powell, Robert B
2017-01-01
This study seeks to understand the degree of body cooling, cold perception and physical discomfort during Antarctic tour excursions. Eight experienced expedition leaders across three Antarctic cruise voyages were monitored during occupational tasks: kayaking, snorkelling and zodiac outings. Subjective cold perception and discomfort were recorded using a thermal comfort assessment and skin temperature was recorded using a portable data logger. Indoor cabin temperature and outdoor temperature with wind velocity were used as measures of environmental stress. Physical activity level and clothing insulation were estimated using previous literature. Tour leaders experienced a 6°C (2°C wind chill) environment for an average of 6 hours each day. Leaders involved in kayaking reported feeling colder and more uncomfortable than other leaders, but zodiac leaders showed greater skin temperature cooling. Occupational experience did not predict body cooling or cold stress perception. These findings indicate that occupational cold stress varies by activity and measurement methodology. The current study effectively used objective and subjective measures of cold-stress to identify factors which can contribute to risk in the Antarctic tourism industry. Results suggest that the type of activity may moderate risk of hypothermia, but not discomfort, potentially putting individuals at risk for cognitive related mistakes and cold injuries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fishbaugher, M. J.
1985-05-01
The decreasing cost of microcomputers along with improvements in power metering circuitry have changed the way in which electrical energy use is monitored. Although utilities still rely on kilowatt-hour (kWh) meters for billing purposes, a microcomputer-based monitoring system is used when greater temporal and end-use resolution is desired. Because these types of monitoring systems will be used increasingly in large-scale conservation and end-use studies, it is important that their performance be analyzed to determine their accuracy. A co-instrumentation test was devised in which two such microcomputer-based monitoring systems made simultaneous measurements of electrical end-uses in two commercial buildings. The analysismore » of the co-instrumentation data aids in the evaluation of microcomputer-based monitoring systems used for end-use measurements. Separate and independent data loggers were used to measure the same loads simultaneously. In addition to these two systems, a utility billing meter measured the total energy use in each building during the co-instrumentation test. The utility's meters provided a relatively accurate standard by which the performance of both loggers could be judged. The comparison between the SCL and PNL microcomputer-based loggers has shown that power measurement techniques directly affect system performance. The co-instrumentation test has shown that there are certain standards that a monitoring system must meet if it is to perform well. First, it is essential to calibrate a microcomputer-based logger against a known standard load before the system is installed. Second, a microcomputer-based system must have some way of accounting for power factors. Recent advances in power metering circuitry have made it relatively easy to apply these power factors automatically in real time.« less
Kim, Hyunjoo; Kang, Suk-Hoon; Choo, Sang-Hyo; Lee, In-Seok; Choi, Kyung-Hwa
2017-01-01
Background: Human body temperature varies with circadian rhythm. To determine the effect of shift work on the circadian rhythm of the distal-skin temperature, wrist temperatures were measured. Methods: Wrist-skin temperatures were measured by an iButton® Temperature Logger. It was measured every 3 min for two and eight consecutive working days in the day and shift workers, respectively. Mesor, amplitude, and acrophase were measured by Cosinor analysis. Results: The shift-worker amplitude dropped significantly as the night shift progressed (0.92 to 0.85 °C), dropped further during rest (0.69 °C), and rose during the morning-shift days (0.82 °C). Day workers still had higher amplitudes (0.93 °C) than the morning-shift workers. The acrophase was delayed during the four night-shift days, then advanced during rest days and the morning-shift days. Nevertheless, the morning-shift worker acrophase was still significantly delayed compared to the day workers (08:03 a.m. vs. 04:11 a.m.). Conclusions: The further reduction of wrist-temperature amplitude during rest after the night shift may be due to the signal circadian rhythm disruption. Reduced amplitudes have been reported to be associated with intolerance to shift work. The findings of our study may help to design the most desirable schedule for shift workers. PMID:28946653
Maloney, Shane K; Fuller, Andrea; Meyer, Leith C R; Kamerman, Peter R; Mitchell, Graham; Mitchell, Duncan
2011-06-01
Using implanted temperature loggers, we measured core body temperature in nine western grey kangaroos every 5 min for 24 to 98 days in spring and summer. Body temperature was highest at night and decreased rapidly early in the morning, reaching a nadir at 10:00 h, after ambient temperature and solar radiation had begun to increase. On hotter days, the minimum morning body temperature was lower than on cooler days, decreasing from a mean of 36.2°C in the spring to 34.0°C in the summer. This effect correlated better with the time of the year than with proximate thermal stressors, suggesting that either season itself or some factor correlated with season, such as food availability, caused the change. Water saving has been proposed as a selective advantage of heterothermy in other large mammals, but in kangaroos the water savings would have been small and not required in a reserve with permanent standing water. We calculate that the lower core temperature could provide energy savings of nearly 7%. It is likely that the heterothermy that we observed on hot days results either from decreased energy intake during the dry season or from a seasonal pattern entrained in the kangaroos that presumably has been selected for because of decreased energy availability during the dry season.
Constantz, James E.; Stonestrom, David A.; Stewart, Amy E.; Niswonger, Richard G.; Smith, Tyson R.
2001-01-01
Spatial and temporal patterns in streamflow are rarely monitored for ephemeral streams. Flashy, erosive streamflows common in ephemeral channels create a series of operational and maintenance problems, which makes it impractical to deploy a series of gaging stations along ephemeral channels. Streambed temperature is a robust and inexpensive parameter to monitor remotely, leading to the possibility of analyzing temperature patterns to estimate streamflow frequency and duration along ephemeral channels. A simulation model was utilized to examine various atmospheric and hydrological upper boundary conditions compared with a series of hypothetical temperature‐monitoring depths within the streambed. Simulation results indicate that streamflow events were distinguished from changing atmospheric conditions with greater certainty using temperatures at shallow depths (e.g., 10–20 cm) as opposed to the streambed surface. Three ephemeral streams in the American Southwest were instrumented to monitor streambed temperature for determining the accuracy of using this approach to ascertain the long‐term temporal and spatial extent of streamflow along each stream channel. Streambed temperature data were collected at the surface or at shallow depth along each stream channel, using thermistors encased in waterproof, single‐channel data loggers tethered to anchors in the channel. On the basis of comparisons with site information, such as direct field observations and upstream flow records, diurnal temperature variations successfully detected the presence and duration of streamflow for all sites.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator regulator with a battery back-up power supply and microprocessor control system is also described. PMID:24442209
Vaccine refrigeration: thinking outside of the box.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator with a battery back-up power supply and microprocessor control system is also described.
Satellite Validation: A Project to Create a Data-Logging System to Monitor Lake Tahoe
NASA Technical Reports Server (NTRS)
Roy, Rudy A.
2005-01-01
Flying aboard the satellite Terra, the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is an imaging instrument used to acquire detailed maps of Earth's surface temperature, elevation, emissivity, and reflectance. An automated site consisting of four buoys was established 6 years ago at Lake Tahoe for the validation of ASTERS thermal infrared data. Using Campbell CR23X Dataloggers, a replacement system to be deployed on a buoy was designed and constructed for the measurement of the lake's temperature profile, surrounding air temperature, humidity, wind direction and speed, net radiation, and surface skin temperature. Each Campbell Datalogger has been programmed to control, power, and monitor 14 different temperature sensors, a JPL-built radiometer, and an RM Young 32500 meteorological station. The logger communicates with the radiometer and meteorological station through a Campbell SDM-SIO4 RS232 serial interface, sending polling commands, and receiving filtered data back from the sensors. This data is then cataloged and sent back across a cellular modem network every hour to JPL. Each instrument is wired via a panel constructed with 18 individual plugs that allow for simple installation and expansion. Data sent back from the system are analyzed at JPL, where they are used to calibrate ASTER data.
NASA Astrophysics Data System (ADS)
Clark, J. F.; Becker, T.; Johnson, T. A.
2013-12-01
Recycling wastewater for potable and nonpotable use by artificially recharging aquifers is a decades-old but increasingly popular practice. Natural attenuation processes in the subsurface, known as soil aquifer treatment (SAT), purify recycled water during recharge and subsequent groundwater flow. Travel time criteria are often used to regulate managed aquifer recharge (MAR) operations. California state draft regulations currently gives preference to groundwater tracers to quantify underground residence time, with a target retention time of >6 months from infiltration to drinking water extraction for surface spreading projects using tertiary treated wastewater (less time may be possible if full advanced treated water is utilized). In the past sulfur hexafluoride, a very strong greenhouse gas, has been the principle deliberate tracer for this work. However, its emission has recently become regulated in California and new tracers are needed. Here, two prospective tracers are evaluated: boron-10 (B-10), the least abundant boron isotope, and heat (with recharging water naturally warmed at the sewage treatment plants and in surface-spreading basins). An additional deliberate tracer, bromide (Br), which is a well-studied conservative tracer, was released as a control. Tracer injection occurred at the San Gabriel Spreading Grounds research test basin in Los Angeles County, CA, USA. The basin was constructed and characterized by the US Geological Survey in the mid-1990s. Recycled wastewater was piped directly to this basin at a known rate (about 1.5 m3/day). Down gradient from the test basin are nine high quality monitoring wells in a line that extends from the center of the basin to 150 m down gradient. All of the wells were equipped with temperature loggers that recorded groundwater temperatures every hour with an accuracy of one thousandth of a degree. The pre-experiment expected arrival times ranged from less than one day to six months. Arrival of Br was always coincident or preceded the B-10 arrival, reflecting retardation of B-10 presumably due to exchange with clay surfaces. B-10/Br travel time ratios determined from the center of mass range from 1 to 1.4. Temperature time series were developed from data loggers. The 1.5° C diurnal temperature variation observed in the spreading pond was only apparent at one well that is screen about 3 m below the pond bottom. At the other wells, we observed temperature increases over a period of days to weeks. Basic analysis of temperature profiles yields a reliable estimate of the underground residence time; heat flow travel times are in good agreement with those derived from the geochemical tracers.
Dahlqvist, Camilla; Hansson, Gert-Åke; Forsman, Mikael
2016-07-01
Repetitive work and work in constrained postures are risk factors for developing musculoskeletal disorders. Low-cost, user-friendly technical methods to quantify these risks are needed. The aims were to validate inclination angles and velocities of one model of the new generation of accelerometers with integrated data loggers against a previously validated one, and to compare meaurements when using a plain reference posture with that of a standardized one. All mean (n = 12 subjects) angular RMS-differences in 4 work tasks and 4 body parts were <2.5° and all mean median angular velocity differences <5.0 °/s. The mean correlation between the inclination signal-pairs was 0.996. This model of the new generation of triaxial accelerometers proved to be comparable to the validated accelerometer using a data logger. This makes it well-suited, for both researchers and practitioners, to measure postures and movements during work. Further work is needed for validation of the plain reference posture for upper arms. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Lavrukova, O S; Popov, V L; Lyabzina, S N; Sidorova, N A; Prikhod'ko, A N
The objective of the present work was to study dynamics of the temperature of a corpse of an experimental animal (a pig) between the moment of death till complete skeletization, The porcine corpse weighing approximately 100 kg was placed in the bilberry spruce forest in the southern part of the Karelian Republic. Variations in the temperature of the corpse were measured with the use of the EClrerk-USB-2Pt logger (an autonomous register of temperature) along with those of the environmental (the air and the soil) temperature during 86 days in the period from June till September. It was shown that the temperature of the corpse first decreased but began to increase thereafter due to the enhancement of the biological activity of microorganisms. It is concluded that putrefactive decomposition of the corpse does not always suggest the necessity to discontinue the measurement of its temperature. The forensic medical examination of a corrupted corpse should take into consideration the possibility of an increase of its temperature in the course of time because it may be a source of a mistake when estimating prescription of death coming. The problem of postmortem rise in the temperature of a corpse undergoing putrefactive decomposition needs a thorough theoretical interpretation with a view to promoting the practical application of the proposed method with due regard for the difference in the environmental conditions in various climatographical regions of the Russian Federation.
NASA Astrophysics Data System (ADS)
McDermott, Frank; Phillips, Dominika
2017-04-01
The conventional view that hydrological inputs (e.g. drip-water degassing) comprise the dominant source of cave air CO2 has been challenged by recent studies that emphasise the importance of direct advection of gaseous CO2from above and beneath cave voids (e.g. 'soil air' and 'ground air'). A better understanding of CO2 gas budgets in caves is important, not only for the correct interpretation of δ13C values and 14C activity data in speleothems, but also for an understanding of the wider role of karst in the global carbon cycle as a source or sink of atmospheric CO2. This study presents new results from a combined air-temperature and CO2 monitoring programme at a small multi-chamber cave in SE Ireland (Ballynamintra cave, Co. Waterford), building on an earlier study at this cave (Baldini et al., 2006). Episodic, low-amplitude but temporally coherent diurnal-scale cave air temperature fluctuations detected almost simultaneously by a series of temperature loggers within the cave were used to detect air mass advection. The sequence and pattern of temperature fluctuations at different locations within the cave enabled the identification of discrete air-inflow and air-outflow events. These diurnal-scale events occur episodically throughout the year in the winter/ spring and summer/autumn temperature ventilation regimes of the cave. Importantly, changes in cave air pCO2 values recorded by an infra-red logger located in the inner chamber a few metres from the back of the cave occur contemporaneously with the air-mass displacement events, and are consistent with direct advection of CO2-rich soil air via fractures in the subjacent cave roof and walls. In the winter regime, episodic diurnal-scale air outflow events draw CO2-rich air over the logger, resulting in short-lived pulses of air, typically containing c. 0.7% CO2 (by volume), several times the ambient cave air CO2 values at this site. Similar events occur during the summer/autumn thermal regime, but these reach higher CO2values (1-1.2%), similar to those measured previously in the overlying soil. Overall, the data confirm an important role for soil and/or ground air sources at this cave and indicate that the episodic CO2 inputs are not controlled by drip-water inputs,. Some recent studies have additionally argued that advected 'ground-air' is not only an important constituent of cave air, but also an important source of carbon in speleothems. This claim is critically evaluated here using 14C activity measurements from actively growing zero-age soda-straw stalactites from the small inner chamber of the cave where the CO2 monitoring was carried out. Surprisingly, soda-straws collected from within a few metres of each other in this inner chamber exhibit quite different 14C activities (93-101 pMC), and are not identical as might be expected if complete carbon isotope exchange had occurred between the dissolved inorganic carbon and the cave atmosphere. The reasons for this will be discussed, drawing on the results of published kinetic models for degassing and isotope exchange. Overall, it is concluded that while the CO2 budget of the air in Ballynamintra cave is dominated by directly advected soil air, water transported dissolved inorganic carbon (DIC) likely remains an important carbon source for its speleothems. Baldini, J.U.L., Baldini, L.M., McDermott, F. and Clipson, N. (2006) Carbon dioxide sources, sinks, and spatial variability in shallow temperate zone caves: evidence from Ballynamintra Cave, Ireland. Journal of Cave and Karst Studies, 68, 4-11.
Romón, Pedro; Aparicio, Domitila; Palacios, Francisco; Iturrondobeitia, Juan Carlos; Hance, Thierry; Goldarazena, Arturo
2017-09-01
Concentrations of four monoterpenes were determined in needles of Pinus radiata (D.Don) (Pinales: Pinaceae) trees that were attacked or nonattacked by Tomicus piniperda (L.) (Coleoptera: Scolytinae). Compounds were identified and quantified by gas chromatography-mass spectrometry. The mean ambient temperature was obtained using climate-recording data loggers. The effect of limonene on field aggregation was also evaluated at three limonene release rates using Lindgren attractant-baited traps and trap logs. Attacked trees produced less α-pinene in March, July, and November than nonattacked trees, less β-pinene in July and November, and less limonene from May to November. Limonene reduced the attraction of T. piniperda to attractant-baited traps and trap logs. Results were linked to better responses to high temperatures, with respect to terpene contents, by the nonattacked trees after the spring attack. © The Author 2017. Published by Oxford University Press on behalf of Entomological Society of America.
NASA Astrophysics Data System (ADS)
Lydersen, Christian; Nøst, Ole Anders; Lovell, Phil; McConnell, Bernie J.; Gammelsrød, Tor; Hunter, Colin; Fedak, Michael A.; Kovacs, Kit M.
2002-12-01
In this study we report results from satellite-linked conductivity-temperature-depth (CTD) loggers that were deployed on wild, free-ranging white whales to study the oceanographic structure of an Arctic fjord, Storfjorden, Svalbard. The whales dove to the bottom of the fjord routinely during the study and occupied areas with up to 90% ice-cover, where performance of conventional ship-based CTD-casts would have been difficult. During the initial period of freezing in the fjord, over a period of approximately 2 weeks, 540 CTD profiles were successfully transmitted. The data indicate that Storfjorden has a substantial inflow of warm North Atlantic Water; this is contrary to conventional wisdom that has suggested that it contains only cold Arctic water. This study confirms that marine-mammal-based CTDs have enormous potential for cost-effective, future oceanographic studies; many different marine mammal species target oceanographic discontinuities for foraging and thus may be good `adaptive samplers' that naturally seek areas of high oceanographic interest.
Temperature rise during polymerization of different cavity liners and composite resins
Karatas, Ozcan; Turel, Verda; Bayindir, Yusuf Ziya
2015-01-01
Objective: The purpose of this study was to evaluate the thermal insulating properties of different light curing cavity liners and composite resins during light emitting diode (LED) curing. Materials and Methods: Sixty-four dentin discs, 1 mm thick and 8 mm in diameter, were prepared. Specimens were divided into four groups. Calcium hydroxide (Ca[OH]2), resin-modified glass ionomer cement, flowable composite and adhesive systems were applied to dentin discs according to the manufacturers’ instructions. The rise in temperature during polymerization with a LED curing unit (LCU) was measured using a K-type thermocouple connected to a data logger. Subsequently, all specimens were randomly divided into one of two groups. A silorane-based composite resin and a methacrylate-based composite resin were applied to the specimens. Temperature rise during polymerization of composite resins with LCU were then measured again. Data were analyzed using one-way ANOVA and post hoc Tukey analyses. Results: There were significant differences in temperature rise among the liners, adhesives, and composite resins (P < 0.05). Silorane-based composite resin exhibited significantly greater temperature rises than methacrylate-based resin (P < 0.05). The smallest temperature rises were observed in Ca(OH)2 specimens. Conclusion: Thermal insulating properties of different restorative materials are important factors in pulp health. Bonding agents alone are not sufficient to protect pulp from thermal stimuli throughout curing. PMID:26751112
Sakatani, Miki; Balboula, Ahmed Z; Yamanaka, Kenichi; Takahashi, Masashi
2012-05-01
This study investigated the effect of summer heat environment on estrous cycles and blood antioxidant levels in Japanese Black cows. A total of 13 non-lactating Japanese Black cows (summer: 9, winter: 4) were examined. Body temperature was measured rectally and intravaginally using a thermometer and data logger, respectively. Estrous behavior was monitored using a radiotelemetric pedometer that recorded walking activity. Rectal temperatures were higher during summer than winter (P<0.001). There was an acute increase in vaginal temperature at the onset of estrus during winter but such an increase was not observed during summer. Walking activity during estrus decreased dramatically in the summer compared to the winter. Duration of estrous cycle was longer in summer (23.4 days, P<0.05) than winter (21.5 days), and the subsequent rise in progesterone concentrations following estrus tended to be delayed in summer. The level of thiobarbituric acid reactive substances (TBARS) in peripheral blood cells was higher during summer (P<0.05), while the levels of superoixde dismutase (SOD), glutathione peroxidase (GPx) and glutathione were lower (P<0.05). These results indicate that high ambient temperature during summer increases both body temperature and oxidative stress, and also reduces signs of estrus in Japanese Black cows. © 2011 The Authors. Animal Science Journal © 2011 Japanese Society of Animal Science.
Kitamura, Tomomi; Bouakhasith, Viraneth; Phounphenghack, Kongxay; Pathammavong, Chansay; Xeuatvongsa, Anonh; Norizuki, Masataro; Okabayashi, Hironori; Mori, Yoshio; Machida, Munehito; Hachiya, Masahiko
2018-04-27
All childhood vaccines, except the oral polio vaccine, should be kept at 2-8 °C, since the vaccine potency can be damaged by heat or freezing temperature. A temperature monitoring study conducted in 2008-2009 reported challenges in cold chain management from the provincial level downwards. The present cross-sectional pilot study aimed to assess the current status of the cold chain in two provinces (Saravan and Xayabouly) of Lao People's Democratic Republic between March-April 2016. Two types of temperature data loggers recorded the temperatures and the proportions of time exposed to < 0 or > 8 °C were calculated. The temperature remained within the appropriate range in the central and provincial storages. However, the vaccines were frequently exposed to > 8 °C in Saravan and < 0 °C in Xayabouly in the district storage. Vaccines were exposed to > 8 °C during the transportation in Saravan and to both > 8 and < 0 °C in Xayabouly. Thus, challenges in managing the cold chain in the district storage and during transportation remain, despite improvements at the provincial storage. A detailed up-to-date nationwide analysis of the current situation of the cold chain is warranted to identify the most appropriate intervention to tackle the remaining challenges.
NASA Astrophysics Data System (ADS)
Domínguez-Villar, David; Cukrov, Neven; Krklec, Kristina
2018-06-01
Although temperature is a nonconservative tracer, it often provides useful information to understand hydrological processes. This study explores the potential of temperature to characterize the hydrological dynamics of a submarine spring and its coastal karst aquifer in Krka Estuary (Croatia). The estuary is well stratified and its water column has a clear thermocline. A network of loggers was designed to monitor the temperature along vertical profiles in the estuary and the coastal aquifer, taking advantage of an anchialine cave that enabled access to the subterranean estuary. The location of the thermocline in the groundwater, which defines the upper boundary of the saline intrusion, depends on (1) the recharge of the aquifer via infiltration of precipitation, (2) the evolution of the thermocline in the estuary, and (3) the tidal oscillations. The sources of water flowing though the anchialine cave were identified: brackish water from the estuary above the thermocline, saline water from the estuary below the thermocline, and freshwater from infiltrated precipitation. A conceptual model is described that characterizes the hydrological dynamics of this coastal aquifer and its interactions with the estuary. Thus, at least for some hydrological settings, temperature is a valid tracer to characterize the main hydrological processes. The measurement of temperature is inexpensive compared to other (conservative) tracers. Therefore, for those hydrological settings that have water masses with distinct temperatures, the use of temperature as a tracer to establish conceptual models of the hydrological dynamics is encouraged.
NASA Astrophysics Data System (ADS)
Vitasse, Yann; Klein, Geoffrey; Kirchner, James W.; Rebetez, Martine
2017-11-01
Some of the world's valleys are famous for having particularly cold microclimates. The La Brevine valley, in the Swiss Jura Mountains, holds the record for the lowest temperature ever measured in an inhabited location in Switzerland. We studied cold air pools (CAPs) in this valley during the winter of 2014-2015 using 44 temperature data loggers distributed between 1033 and 1293 m asl. Our goals were to (i) describe the climatic conditions under which CAPs form in the valley, (ii) examine the spatial configuration and the temperature structure of the CAPs and (iii) quantify how often temperature inversions occur in winter using long-term series of temperature from the valley floor. Our results show that CAPs occurred every second night, on average, during the winter of 2014-2015 and were typically formed under cloudless, windless and high-pressure conditions. Strong temperature inversions up to 28 °C were detected between the valley floor and the surrounding hills. The spatial temperature structure of the CAPs varies among the different inversion days, with the upper boundary of the cold pool generally situated at about 1150 m asl. Although mean temperatures have increased in this area over the period 1960-2015 in connection with climate change, the occurrences of extreme cold temperatures did not decrease in winter and are highly correlated with the North Atlantic Oscillation and the East Atlantic indices. This suggests that CAPs in sheltered valleys are largely decoupled from the free atmosphere temperature and will likely continue to occur in the next decades under warmer conditions.
Wright, Caradee Y.; Street, Renée A.; Cele, Nokulunga; Kunene, Zamantimande; Balakrishna, Yusentha; Albers, Patricia N.; Mathee, Angela
2017-01-01
Increased temperatures affect human health and vulnerable groups including infants, children, the elderly and people with pre-existing diseases. In the southern African region climate models predict increases in ambient temperature twice that of the global average temperature increase. Poor ventilation and lack of air conditioning in primary health care clinics, where duration of waiting time may be as long as several hours, pose a possible threat to patients seeking primary health care. Drawing on information measured by temperature loggers installed in eight clinics in Giyani, Limpopo Province of South Africa, we were able to determine indoor temperatures of waiting rooms in eight rural primary health care facilities. Mean monthly temperature measurements inside the clinics were warmer during the summer months of December, January and February, and cooler during the autumn months of March, April and May. The highest mean monthly temperature of 31.4 ± 2.7 °C was recorded in one clinic during February 2016. Maximum daily indoor clinic temperatures exceeded 38 °C in some clinics. Indoor temperatures were compared to ambient (outdoor) temperatures and the mean difference between the two showed clinic waiting room temperatures were higher by 2–4 °C on average. Apparent temperature (AT) incorporating relative humidity readings made in the clinics showed ‘realfeel’ temperatures were >4 °C higher than measured indoor temperature, suggesting a feeling of ‘stuffiness’ and discomfort may have been experienced in the waiting room areas. During typical clinic operational hours of 8h00 to 16h00, mean ATs fell into temperature ranges associated with heat–health impact warning categories of ‘caution’ and ‘extreme caution’. PMID:28067816
Wright, Caradee Y; Street, Renée A; Cele, Nokulunga; Kunene, Zamantimande; Balakrishna, Yusentha; Albers, Patricia N; Mathee, Angela
2017-01-06
Increased temperatures affect human health and vulnerable groups including infants, children, the elderly and people with pre-existing diseases. In the southern African region climate models predict increases in ambient temperature twice that of the global average temperature increase. Poor ventilation and lack of air conditioning in primary health care clinics, where duration of waiting time may be as long as several hours, pose a possible threat to patients seeking primary health care. Drawing on information measured by temperature loggers installed in eight clinics in Giyani, Limpopo Province of South Africa, we were able to determine indoor temperatures of waiting rooms in eight rural primary health care facilities. Mean monthly temperature measurements inside the clinics were warmer during the summer months of December, January and February, and cooler during the autumn months of March, April and May. The highest mean monthly temperature of 31.4 ± 2.7 °C was recorded in one clinic during February 2016. Maximum daily indoor clinic temperatures exceeded 38 °C in some clinics. Indoor temperatures were compared to ambient (outdoor) temperatures and the mean difference between the two showed clinic waiting room temperatures were higher by 2-4 °C on average. Apparent temperature (AT) incorporating relative humidity readings made in the clinics showed 'realfeel' temperatures were >4 °C higher than measured indoor temperature, suggesting a feeling of 'stuffiness' and discomfort may have been experienced in the waiting room areas. During typical clinic operational hours of 8h00 to 16h00, mean ATs fell into temperature ranges associated with heat-health impact warning categories of 'caution' and 'extreme caution'.
NASA Astrophysics Data System (ADS)
Blake, Sarah; Jones, Alan G.; Henry, Tiernan
2015-04-01
Irish warm springs are one of a set of several target types that are being evaluated for their geothermal energy potential during the course of the island-wide assessment of the geothermal energy potential of Ireland under the IRETHERM project (www.iretherm.ie). Forty-two warm springs and warm shallow groundwater occurrences have been recorded in Ireland; water temperatures in the springs (approx. 12-25 °C) are elevated with respect to average Irish groundwater temperatures (10-11 °C). This study focuses on warm springs in east-central Ireland found in the Carboniferous limestone of the Dublin Basin. A combination of geophysical methods (controlled source electromagnetics (CSEM) and audio-magnetotellurics (AMT)) and hydrochemical analyses (including time-lapse temperature and electrical conductivity measurements) have been utilised at several of the springs to determine the source of the heated waters at depth and the nature of the geological structures that deliver the warm waters to the surface. Using the example of St. Gorman's Well, Co. Meath, we show how the combination of these different methods of investigation and the interpretation of these various data sets enables us to better understand the physical and chemical variability of the spring through time. This will provide the basis for an assessment of the source of these thermal waters as a potential geothermal energy reservoir and will allow for more precise characterisation of the groundwater resource. We present subsurface models derived from new geophysical data collected at St. Gorman's Well in 2013. This high-resolution AMT survey consisted of a grid of 40 soundings recorded at approximately 200 m intervals centred on the spring. The aim of the survey was to image directly any (electrically conductive) fluid conduit systems that may be associated with the springs and to provide an understanding of the observed association of the Irish warm springs with major structural lineaments, such as the NE-SW Caledonian structural trend which dominates Irish geology. Seasonal hydrochemical sampling of six warm spring locations commenced in July 2013. Data loggers installed at each location measured temperature and electrical conductivity (15-minute sampling intervals) throughout the sampling period (July 2013 - early 2015). The hydrochemical results and the data from the logger at St. Gorman's Well are examined here in conjunction with regional rainfall and available hydrogeological information in order to establish the nature of the relationship between the hydrological cycle and fluctuations in the hydrochemistry of the spring.
Smith, J F; Bradford, B J; Harner, J P; Potts, J C; Allen, J D; Overton, M W; Ortiz, X A; Collier, R J
2016-02-01
A trial was performed to assess the effect of evaporative pads on core body temperature (CBT) and lying behavior of lactating Holstein cows housed in cross-ventilated freestall facilities in a humid environment. This trial was undertaken in 2 barns equipped with (EP) or without (NP) evaporative pads. Each facility had 4 pens, 1 baffle/pen, and a nominal width of 122 m. Stocking density was higher (123.4 vs. 113.1%) and freestalls were slightly shorter (2.3 vs. 2.4 m) and narrower (1.16 vs. 1.21 m) in EP compared with NP barns. In each pen, lying behavior of 20 cows was monitored using electronic data loggers that recorded at 1-min intervals. A subset (n=14) of these cows within each pen were also fitted with temperature loggers attached to blank controlled intravaginal drug release devices to determine CBT every 5 min. Ambient conditions were collected every 15 min. Individual cow lying duration and lying bouts were assessed for each cow, as well as time spent standing and CBT within the following categories: CBT <38.6°C, and CBT >38.6, >38.9, >39.2, >39.4, and >39.7°C. These variables were analyzed using pen as the experimental unit, with cow and day as additional random effects. The average maximum ambient conditions over the 9 d were 25°C and 78.74% relative humidity. No differences were observed in lying duration and number of lying bouts over the 9-d period, with overall means of 696±31 min/d and 12.6±0.5 bouts/d. The EP cows spent 170 min/d longer with a CBT <38.6°C and 107 min/d less with CBT >39.2°C than did NP cows. Cooling with evaporative pads tended to increase time spent lying with a CBT >8.6°C and lying bouts/d for EP cows versus NP cows. Results from this trial show that even under mild heat stress, evaporative cooling in cross-ventilated facilities can decrease CBT and tended to increase lying time. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Croghan, Danny; Van Loon, Anne; Bradley, Chris; Sadler, Jon; Hannnah, David
2017-04-01
Studies relating rainfall events to river water quality are frequently hindered by the lack of high resolution rainfall data. Local studies are particularly vulnerable due to the spatial variability of precipitation, whilst studies in urban environments require precipitation data at high spatial and temporal resolutions. The use of point-source data makes identifying causal effects of storms on water quality problematic and can lead to erroneous interpretations. High spatial and temporal resolution rainfall radar data offers great potential to address these issues. Here we use rainfall radar data with a 1km spatial resolution and 5 minute temporal resolution sourced from the UK Met Office Nimrod system to study the effects of storm events on water temperature (WTemp) in Birmingham, UK. 28 WTemp loggers were placed over 3 catchments on a rural-urban land use gradient to identify trends in WTemp during extreme events within urban environments. Using GIS, the catchment associated with each logger was estimated, and 5 min. rainfall totals and intensities were produced for each sub-catchment. Comparisons of rainfall radar data to meteorological stations in the same grid cell revealed the high accuracy of rainfall radar data in our catchments (<5% difference for studied months). The rainfall radar data revealed substantial differences in rainfall quantity between the three adjacent catchments. The most urban catchment generally received more rainfall, with this effect greatest in the highest intensity storms, suggesting the possibility of urban heat island effects on precipitation dynamics within the catchment. Rainfall radar data provided more accurate sub-catchment rainfall totals allowing better modelled estimates of storm flow, whilst spatial fluctuations in both discharge and WTemp can be simply related to precipitation intensity. Storm flow inputs for each sub-catchment were estimated and linked to changes in WTemp. WTemp showed substantial fluctuations (>1 °C) over short durations (<30 minutes) during storm events in urbanised sub-catchments, however WTemp recovery times were more prolonged. Use of the rainfall radar data allowed increased accuracy in estimates of storm flow timings and rainfall quantities at each sub-catchment, from which the impact of storm flow on WTemp could be quantified. We are currently using the radar data to derive thresholds for rainfall amount and intensity at which these storm deviations occur for each logger, from which the relative effects of land use and other catchment characteristics in each sub-catchment can be assessed. Our use of the rainfall radar data calls into question the validity of using station based data for small scale studies, particularly in urban areas, with high variation apparent in rainfall intensity both spatially and temporally. Variation was particularly high within the heavily urbanised catchment. For water quality studies, high resolution rainfall radar can be implemented to increase the reliability of interpretations of the response of water quality variables to storm water inputs in urban catchments.
Near-surface temperature lapse rates in a mountainous catchment in the Chilean Andes
NASA Astrophysics Data System (ADS)
Ayala; Schauwecker, S.; Pellicciotti, F.; McPhee, J. P.
2011-12-01
In mountainous areas, and in the Chilean Andes in particular, the irregular and sparse distribution of recording stations resolves insufficiently the variability of climatic factors such as precipitation, temperature and relative humidity. Assumptions about air temperature variability in space and time have a strong effect on the performance of hydrologic models that represent snow processes such as accumulation and ablation. These processes have large diurnal variations, and assumptions that average over longer time periods (days, weeks or months) may reduce the predictive capacity of these models under different climatic conditions from those for which they were calibrated. They also introduce large uncertainties when such models are used to predict processes with strong subdiurnal variability such as snowmelt dynamics. In many applications and modeling exercises, temperature is assumed to decrease linearly with elevation, using the free-air moist adiabatic lapse rate (MALR: 0.0065°C/m). Little evidence is provided for this assumption, however, and recent studies have shown that use of lapse rates that are uniform in space and constant in time is not appropriate. To explore the validity of this approach, near-surface (2 m) lapse rates were calculated and analyzed at different temporal resolution, based on a new data set of spatially distributed temperature sensors setup in a high elevation catchment of the dry Andes of Central Chile (approx. 33°S). Five minutes temperature data were collected between January 2011 and April 2011 in the Ojos de Agua catchment, using two Automatic Weather Stations (AWSs) and 13 T-loggers (Hobo H8 Pro Temp with external data logger), ranging in altitude from 2230 to 3590 m.s.l.. The entire catchment was snow free during our experiment. We use this unique data set to understand the main controls over temperature variability in time and space, and test whether lapse rates can be used to describe the spatial variations of air temperature in a high elevation catchment. Our main result is that the assumption of a MALR is appropriate to describe the average variability of temperature over the entire measurement period (and possibly for daily scales), but that hourly near-surface lapse rates vary considerably and can deviate strongly from the MALR. This diurnal variability in lapse rates is associated with changes in wind direction and variations in wind velocity. Shallow lapse rates, in particular, occur during the morning, in correspondence to low wind speeds and change in wind direction from katabatic wind to valley wind and are associated with a weaker correlation between air temperature and elevation, while steeper lapse rates (meaning by this that temperature decreases more with elevation) closer to the MALR are typical of the afternoon hours from 13.00 on (and correspond to high wind speed), and are representative of a more linear dependency between air temperature and elevation. The steepest LRs, however, occur in the evening at 20.00-21.00, when wind velocity drops again and wind direction changes from valley wind to katabatic wind. It is clear that the wind regime is the main controls on LRs variability, and it is important to validate these findings with data sets from a second season.
Agha, Mickey; Price, Steven J; Nowakowski, A Justin; Augustine, Ben; Todd, Brian D
2017-04-20
Emerging infectious diseases cause population declines in many ectotherms, with outbreaks frequently punctuated by periods of mass mortality. It remains unclear, however, whether thermoregulation by ectotherms and variation in environmental temperature is associated with mortality risk and disease progression, especially in wild populations. Here, we examined environmental and body temperatures of free-ranging eastern box turtles Terrapene carolina during a mass die-off coincident with upper respiratory disease. We recorded deaths of 17 turtles that showed clinical signs of upper respiratory disease among 76 adult turtles encountered in Berea, Kentucky (USA), in 2014. Of the 17 mortalities, 11 occurred approximately 14 d after mean environmental temperature dropped 2.5 SD below the 3 mo mean. Partial genomic sequencing of the major capsid protein from 1 sick turtle identified a ranavirus isolate similar to frog virus 3. Turtles that lacked clinical signs of disease had significantly higher body temperatures (23°C) than sick turtles (21°C) during the mass mortality, but sick turtles that survived and recovered eventually warmed (measured by temperature loggers). Finally, there was a significant negative effect of daily environmental temperature deviation from the 3 mo mean on survival, suggesting that rapid decreases in environmental temperature were correlated with mortality. Our results point to a potential role for environmental temperature variation and body temperature in disease progression and mortality risk of eastern box turtles affected by upper respiratory disease. Given our findings, it is possible that colder or more variable environmental temperatures and an inability to effectively thermoregulate are associated with poorer disease outcomes in eastern box turtles.
An automated digital imaging system for environmental monitoring applications
Bogle, Rian; Velasco, Miguel; Vogel, John
2013-01-01
Recent improvements in the affordability and availability of high-resolution digital cameras, data loggers, embedded computers, and radio/cellular modems have advanced the development of sophisticated automated systems for remote imaging. Researchers have successfully placed and operated automated digital cameras in remote locations and in extremes of temperature and humidity, ranging from the islands of the South Pacific to the Mojave Desert and the Grand Canyon. With the integration of environmental sensors, these automated systems are able to respond to local conditions and modify their imaging regimes as needed. In this report we describe in detail the design of one type of automated imaging system developed by our group. It is easily replicated, low-cost, highly robust, and is a stand-alone automated camera designed to be placed in remote locations, without wireless connectivity.
Smart guidewires for smooth navigation in neurovascular intervention
NASA Astrophysics Data System (ADS)
Chen, Yanfei; Barry, Matthew M.; Shayan, Mahdis; Jankowitz, Brian T.; Duan, Xinjie; Robertson, Anne M.; Chyu, Minking K.; Chun, Youngjae
2015-04-01
A smart guidewire using nitinol materials was designed, manufactured and evaluated the device functionality, such as bending performance, trackability, thermal effects, and thrombogenic response. Two types of nitinol material were partially used to enhance the guidewire trackability. A proposed smart guidewire system uses either one- or two-way shape-memory alloy nitinol (1W-SMA, 2W-SMA) wires (0.015, 381µm nitinol wire). Bending stiffness was measured using in vitro test system, which contains the NI USB-9162 data logger and LabView Signal Express 2010. Temperature distribution and displacement were evaluated via recording a 60Hz movie using a SC325 camera. Hemocompatibility was evaluated by scanning electron microscopy after one heating cycle of nitinol under the Na-citrate porcine whole blood circulation. A smart guidewire showed 30 degrees bending after applying or disconnecting electrical current. While the temperature of the nitinol wires increased more than 70 °C, the surrounding temperature with the commercially available catheter coverings showed below human body temperature showing 30 ̴ 33 °C. There was no significant platelet attachment or blood coagulation when the guidewire operates. Novel smart guidewires have been developed using shape memory alloy nitinol, which may represent a novel alternative to typical commercially available guidewires for interventional procedures.
Task-dependent cold stress during expeditions in Antarctic environments
Morris, Drew M.; Pilcher, June J.; Powell, Robert B.
2017-01-01
ABSTRACT This study seeks to understand the degree of body cooling, cold perception and physical discomfort during Antarctic tour excursions. Eight experienced expedition leaders across three Antarctic cruise voyages were monitored during occupational tasks: kayaking, snorkelling and zodiac outings. Subjective cold perception and discomfort were recorded using a thermal comfort assessment and skin temperature was recorded using a portable data logger. Indoor cabin temperature and outdoor temperature with wind velocity were used as measures of environmental stress. Physical activity level and clothing insulation were estimated using previous literature. Tour leaders experienced a 6°C (2°C wind chill) environment for an average of 6 hours each day. Leaders involved in kayaking reported feeling colder and more uncomfortable than other leaders, but zodiac leaders showed greater skin temperature cooling. Occupational experience did not predict body cooling or cold stress perception. These findings indicate that occupational cold stress varies by activity and measurement methodology. The current study effectively used objective and subjective measures of cold-stress to identify factors which can contribute to risk in the Antarctic tourism industry. Results suggest that the type of activity may moderate risk of hypothermia, but not discomfort, potentially putting individuals at risk for cognitive related mistakes and cold injuries. PMID:28990466
Changes in dive profiles as an indicator of feeding success in king and Adélie penguins
NASA Astrophysics Data System (ADS)
Bost, C. A.; Handrich, Y.; Butler, P. J.; Fahlman, A.; Halsey, L. G.; Woakes, A. J.; Ropert-Coudert, Y.
2007-02-01
Determining when and how deep avian divers feed remains a challenge despite technical advances. Systems that record oesophageal temperature are able to determine rate of prey ingestion with a high level of accuracy but technical problems still remain to be solved. Here we examine the validity of using changes in depth profiles to infer feeding activity in free-ranging penguins, as more accessible proxies of their feeding success. We used oesophageal temperature loggers with fast temperature sensors, deployed in tandem with time-depth recorders, on king and Adélie penguins. In the king penguin, a high correspondence was found between the number of ingestions recorded per dive and the number of wiggles during the bottom and the ascent part of the dives. In the Adélie penguins, which feed on smaller prey, the number of large temperature drops was linearly related to the number of undulations per dive. The analysis of change in depth profiles from high-resolution time-depth recorders can provide key information to enhance the study of feeding rate and foraging success of these predators. Such potential is especially relevant in the context of using Southern marine top predators to study change in availability of marine resources.
Theisinger, Ole; Berg, W; Dausmann, K H
2017-08-01
Physiological or behavioural adjustments are a prerequisite for ectotherms to cope with different thermal environments. One of the world's steepest environmental gradients in temperature and precipitation can be found in southeastern Madagascar. This unique gradient allowed us to study the compensation of thermal constraints in the heliothermic lizard Oplurus quadrimaculatus on a very small geographic scale. The lizard occurs from hot spiny forest to intermediate gallery and transitional forest to cooler rain forest and we investigated whether these habitat differences are compensated behaviourally or physiologically. To study activity skin temperature (as proxy for body temperature) and the activity time of lizards, we attached temperature loggers to individuals in three different habitats. In addition, we calculated field resting costs from field resting metabolic rate to compare energy expenditure along the environmental gradient. We found no variation in activity skin temperature, despite significant differences in operative environmental temperature among habitats. However, daily activity time and field resting costs were reduced by 35% and 28% in the cool rain forest compared to the hot spiny forest. Our study shows that O. quadrimaculatus relies on behavioural mechanisms rather than physiological adjustments to compensate thermal differences between habitats. Furthermore, its foraging activity in open, sun exposed habitats facilitates such a highly effective thermoregulation that cold operative temperature, not energetically expensive heat, presents a greater challenge for these lizards despite living in a hot environment. Copyright © 2017. Published by Elsevier Ltd.
Development of autonomous gamma dose logger for environmental monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jisha, N. V.; Krishnakumar, D. N.; Surya Prakash, G.
2012-03-15
Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system ismore » totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.« less
Phillips, Nathan; Bond, Barbara J.
1999-07-01
To record photosynthetically active radiation (PAR) simultaneously at a number of points throughout a forest canopy, we developed a simple, inexpensive (< $10 US) current-to-voltage converter that processes the current generated by a photodiode radiation sensor to a voltage range that is recordable with a miniature data logger. The converter, which weighs less than 75 g and has a volume of only 100 cm(3), is built around an ultra-low power OP-90 precision operational amplifier, which consumes less than 0.5 mA at 9 V when converting the output of a Li-Cor LI-190SA quantum sensor exposed to photosynthetically active radiation (PAR) of 2500 &mgr;mol m(-2) s(-1) or only 5 &mgr;A in low light. A small 9-V battery thus powers the amplifier for more than 1000 h of continuous operation. Correlations between photometer readings and voltage output from the current-to-voltage converter were high and linear at both high and low PAR. Sixteen Li-Cor LI-190SA quantum sensors each equipped with current-to-voltage converters and connected to a miniature data logger were deployed in the upper branches of a Panamanian tropical rainforest canopy. Each unit performed reliably during a one- or two-week evaluation.
Development of autonomous gamma dose logger for environmental monitoring
NASA Astrophysics Data System (ADS)
Jisha, N. V.; Krishnakumar, D. N.; Surya Prakash, G.; Kumari, Anju; Baskaran, R.; Venkatraman, B.
2012-03-01
Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify 41Ar, proving its utility for real-time plume tracking and source term estimation.
Does behavioural thermoregulation underlie seasonal movements in Lake Erie walleye?
Raby, Graham D.; Vandergoot, Christopher; Hayden, Todd A.; Faust, Matthew D.; Kraus, Richard T.; Dettmers, John M.; Cooke, Steven J.; Zhao, Yingming; Fisk, Aaron T.; Krueger, Charles C.
2018-01-01
Thermoregulation is presumed to be a widespread determinant of behaviour in fishes, but has not often been investigated as a mechanism shaping long-distance migrations. We used acoustic telemetry and animal-borne thermal loggers to test the hypothesis that seasonal migration in adult walleye (Sander vitreus) in Lake Erie is size- and (or) sex-specific and related to behavioural thermoregulation. Female walleye migrated out of the warm, shallow western basin earlier than did males and were 1.8 times more likely to be detected on acoustic receivers in the deeper and cooler eastern basin. The few fish that remained in the western basin were restricted to a smaller range of higher temperatures (≥20 °C) than those that migrated to the central and eastern basins (∼16–21 °C). However, temperature records from walleye in the central basin were nearly indistinguishable from those in the eastern basin, suggesting thermal preferences alone could not explain migration to the eastern basin. As such, our effort to understand the mechanisms that cause migratory behaviours has generated mixed evidence on the role of temperature and that factors like foraging opportunities may have synergistic roles in the migration.
Pakhare, Abhijit P; Bali, Surya; Pawar, Radhakishan B; Lokhande, Ganesh S
2014-01-01
India was certified polio free on 27 March 2014. Supplementary immunization activities, in the form of national immunization days, is one of the core strategies for eradication, where oral polio vaccine is administered to children aged under 5 years throughout the country. Oral polio vaccine is heat sensitive and requires maintenance of a stringent cold chain. Therefore, vaccine carriers with ice packs are used in the Pulse Polio Immunization (PPI) programme. This study assessed whether the cold chain is maintained during National Immunization Day in Beed district. A cross-sectional study was conducted at six randomly selected booths, one each from six primary health centres in Georai block of Beed district in Maharashtra. Electronic data loggers, configured to measure half-hourly temperatures, were kept in vaccine carriers throughout the day of PPI. The vaccine carrier temperature was below 8 °C at all six booths; minimum temperature recorded was -9.5 °C, while the maximum was 4.5 °C. The vaccine vial monitor did not reach discard point in any booth. A vaccine carrier with four ice packs very effectively maintains the cold chain required for oral polio vaccine.
NASA Astrophysics Data System (ADS)
Karan, S.; Sebok, E.; Engesgaard, P. K.
2016-12-01
For identifying groundwater seepage locations in small streams within a headwater catchment, we present a method expanding on the linear regression of air and stream temperatures. Thus, by measuring the temperatures in dual-depth; in the stream column and at the streambed-water interface (SWI), we apply metrics from linear regression analysis of temperatures between air/stream and air/SWI (linear regression slope, intercept and coefficient of determination), and the daily mean temperatures (temperature variance and the average difference between the minimum and maximum daily temperatures). Our study show that using metrics from single-depth stream temperature measurements only are not sufficient to identify substantial groundwater seepage locations within a headwater stream. Conversely, comparing the metrics from dual-depth temperatures show significant differences so that at groundwater seepage locations, temperatures at the SWI, merely explain 43-75 % of the variation opposed to ≥91 % at the corresponding stream column temperatures. The figure showing a box-plot of the variation in daily mean temperature depict that at several locations there is great variation in the range the upper and lower loggers due to groundwater seepage. In general, the linear regression show that at these locations at the SWI, the slopes (<0.25) and intercepts (>6.5oC) are substantially lower and higher, while the mean diel amplitudes (<0.98oC) are decreased compared to remaining locations. The dual-depth approach was applied in a post-glacial fluvial setting, where metrics analyses overall corresponded to field measurements of groundwater fluxes deduced from vertical streambed temperatures and stream flow accretions. Thus, we propose a method reliably identifying groundwater seepage locations along streambed in such settings.
Hetem, Robyn Sheila; Strauss, Willem Maartin; Fick, Linda Gayle; Maloney, Shane Kevin; Meyer, Leith Carl Rodney; Shobrak, Mohammed; Fuller, Andrea; Mitchell, Duncan
2010-10-01
Heterothermy, a variability in body temperature beyond the limits of homeothermy, has been advanced as a key adaptation of Arabian oryx (Oryx leucoryx) to their arid-zone life. We measured body temperature using implanted data loggers, for a 1-year period, in five oryx free-living in the deserts of Saudi Arabia. As predicted for adaptive heterothermy, during hot months compared to cooler months, not only were maximum daily body temperatures higher (41.1 ± 0.3 vs. 39.7 ± 0.1°C, P = 0.0002) but minimum daily body temperatures also were lower (36.1 ± 0.3 vs. 36.8 ± 0.2°C, P = 0.04), resulting in a larger daily amplitude of the body temperature rhythm (5.0 ± 0.5 vs. 2.9 ± 0.2°C, P = 0.0007), while mean daily body temperature rose by only 0.4°C. The maximum daily amplitude of the body temperature rhythm reached 7.7°C for two of our oryx during the hot-dry period, the largest amplitude ever recorded for a large mammal. Body temperature variability was influenced not only by ambient temperature but also water availability, with oryx displaying larger daily amplitudes of the body temperature rhythm during warm-dry months compared to warm-wet months (3.6 ± 0.6 vs. 2.3 ± 0.3°C, P = 0.005), even though ambient temperatures were the same. Free-living Arabian oryx therefore employ heterothermy greater than that recorded in any other large mammal, but water limitation, rather than high ambient temperature, seems to be the primary driver of this heterothermy.
LaZerte, Stefanie E; Reudink, Matthew W; Otter, Ken A; Kusack, Jackson; Bailey, Jacob M; Woolverton, Austin; Paetkau, Mark; de Jong, Adriaan; Hill, David J
2017-10-01
Radio frequency identification (RFID) provides a simple and inexpensive approach for examining the movements of tagged animals, which can provide information on species behavior and ecology, such as habitat/resource use and social interactions. In addition, tracking animal movements is appealing to naturalists, citizen scientists, and the general public and thus represents a tool for public engagement in science and science education. Although a useful tool, the large amount of data collected using RFID may quickly become overwhelming. Here, we present an R package (feedr) we have developed for loading, transforming, and visualizing time-stamped, georeferenced data, such as RFID data collected from static logger stations. Using our package, data can be transformed from raw RFID data to visits, presence (regular detections by a logger over time), movements between loggers, displacements, and activity patterns. In addition, we provide several conversion functions to allow users to format data for use in functions from other complementary R packages. Data can also be visualized through static or interactive maps or as animations over time. To increase accessibility, data can be transformed and visualized either through R directly, or through the companion site: http://animalnexus.ca, an online, user-friendly, R-based Shiny Web application. This system can be used by professional and citizen scientists alike to view and study animal movements. We have designed this package to be flexible and to be able to handle data collected from other stationary sources (e.g., hair traps, static very high frequency (VHF) telemetry loggers, observations of marked individuals in colonies or staging sites), and we hope this framework will become a meeting point for science, education, and community awareness of the movements of animals. We aim to inspire citizen engagement while simultaneously enabling robust scientific analysis.
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp.
Kahvecioglu, Firdevs; Tosun, Gül; Ülker, Hayriye Esra
2016-01-01
Objectives . To measure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Methods . Nonretentive class I cavities were prepared in extracted primary and permanent molars. Glass carbomer (GC) was placed in the cavity and set at 60°C for 60 sn using a special thermocure lamp. Resin-modified glass ionomer (RMGIC) and polyacid-modified composite resin (PMCR) were placed in the cavities and polymerized with an LED curing unit. Temperature increases during setting reactions were measured with a J-type thermocouple wire connected to a data logger. Data were examined using two-way analysis of variance and Tukey's honestly significant difference tests. Results . The use of GC resulted in temperature changes of 5.17 ± 0.92°C and 5.32 ± 0.90°C in primary and permanent teeth, respectively ( p > 0.05). Temperature increases were greatest in the GC group, differing significantly from those in the PMCR group ( p < 0.05). Conclusion . Temperature increases during polymerization and setting reactions of the materials were below the critical value in all groups. No difference was observed between primary and permanent teeth, regardless of the material used.
Hall, L. Embere; Chalfoun, Anna D.; Beever, Erik; Loosen, Anne E.
2016-01-01
BackgroundContemporary climate change is affecting nearly all biomes, causing shifts in animal distributions, phenology, and persistence. Favorable microclimates may buffer organisms against rapid changes in climate, thereby allowing time for populations to adapt. The degree to which microclimates facilitate the local persistence of climate-sensitive species, however, is largely an open question. We addressed the importance of microrefuges in mammalian thermal specialists, using the American pika (Ochotona princeps) as a model organism. Pikas are sensitive to ambient temperatures, and are active year-round in the alpine where conditions are highly variable. We tested four hypotheses about the relationship between microrefuges and pika occurrence: 1) Local-habitat Hypothesis (local-habitat conditions are paramount, regardless of microrefuge); 2) Surface-temperature Hypothesis (surrounding temperatures, unmoderated by microrefuge, best predict occurrence); 3) Interstitial-temperature Hypothesis (temperatures within microrefuges best predict occurrence), and 4) Microrefuge Hypothesis (the degree to which microrefuges moderate the surrounding temperature facilitates occurrence, regardless of other habitat characteristics). We examined pika occurrence at 146 sites across an elevational gradient. We quantified pika presence, physiographic habitat characteristics and forage availability at each site, and deployed paired temperature loggers at a subset of sites to measure surface and subterranean temperatures.ResultsWe found strong support for the Microrefuge Hypothesis. Pikas were more likely to occur at sites where the subsurface environment substantially moderated surface temperatures, especially during the warm season. Microrefugium was the strongest predictor of pika occurrence, independent of other critical habitat characteristics, such as forage availability.ConclusionsBy modulating surface temperatures, microrefuges may strongly influence where temperature-limited animals persist in rapidly warming environments. As climate change continues to manifest, efforts to understand the changing dynamics of animal-habitat relationships will be enhanced by considering the quality of microrefuges.
NASA Astrophysics Data System (ADS)
Anderson, V. J.; Shanahan, T. M.; Saylor, J.; Horton, B. K.
2012-12-01
Recently, the distribution of branched GDGT's (glycerol dialkyl glycerol tetraethers) has been proposed as a proxy for temperature and pH in soils via the MBT/CBT index, and has been used to reconstruct past temperature variations in a number of settings ranging from marine sediments to loess deposits and paleosols. However, empirical calibrations of the MBT/CBT index against temperature show significant scatter, leading to uncertainties as large as ±2 degrees C . In this study we seek to add to and improve upon the existing soil calibration using a new set of samples spanning a large elevation (and temperature) gradient in the Eastern Cordillera of Colombia. At each site we buried temperature loggers to constrain the diurnal and seasonal temperature experienced by each soil sample. Located only 5 degrees north of the equator, our sites experience a very small seasonal temperature variation - most sites display an annual range of less than 4 degrees C. In addition, the pH of all of the soils is almost invariant across the transect, with the vast majority of samples having pH's between 4 and 5. This dataset represents a "best-case" scenario - small variations in seasonal temperature, pH, and well-constrained instrumental data - which allow us to examine the brGDGT-temperature relationship in the absence of major confounding factors such as seasonality and soil chemistry. Interestingly, the relationship between temperature and the MBT/CBT index is not improved using this dataset, suggesting that these factors are not the cause of the anomalous scatter in the calibration dataset. However, we find that using other parameterizations for the regression equation instead of the MBT and CBT indices, the errors in our temperature estimates are significantly reduced.
Development of software for geodynamic processes monitoring system
NASA Astrophysics Data System (ADS)
Kabanov, M. M.; Kapustin, S. N.; Gordeev, V. F.; Botygin, I. A.; Tartakovsky, V. A.
2017-11-01
This article justifies the usage of natural pulsed electromagnetic Earth's noises logging method for mapping anomalies of strain-stress state of Earth's crust. The methods and technologies for gathering, processing and systematization of data gathered by ground multi-channel geophysical loggers for monitoring geomagnetic situation have been experimentally tested, and software had been developed. The data was consolidated in a network storage and can be accessed without using any specialized client software. The article proposes ways to distinguish global and regional small-scale time-space variations of Earth's natural electromagnetic field. For research purposes, the software provides a way to export data for any given period of time for any loggers and displays measurement data charts for selected set of stations.
Hydrothermal disturbances at the Norris Geyser Basin, Yellowstone National Park (USA) in 2003
NASA Astrophysics Data System (ADS)
Lowenstern, J. B.; Heasler, H.; Smith, R. B.
2003-12-01
The Norris Geyser Basin in north-central Yellowstone National Park (YNP) experienced a series of notable changes during 2003, including formation of new hot springs and fumaroles, renewed activity of dormant geysers and elevated ground temperatures. This abstract provides a short synopsis of the new hydrothermal activity. In 2000, Yellowstone's tallest geyser, Steamboat, erupted after a dormant period of nearly 9 years. It erupted twice in 2002 and then again on 26 March and 27 April 2003. Surges in flux of thermal water preceding the eruptions (preplay) were recorded by a couplet of temperature data loggers placed in the outlet stream. The data indicated pulses of water flow with 1 and ~3 day intervals. On 10 July 2003, a new thermal feature was reported just west of Nymph Lake, ~ 3.5 km northwest of the Norris Museum. A linear series of vigorous fumaroles, about 75 m long had formed in a forested area, ~ 200 m up a hill on the lake's west shore. Fine particles of rock and mineral fragments coated nearby vegetation. Fumarole temperatures were around the local boiling temperature of water (92° C). After two months, somewhat reduced steam emission was accompanied by discharge of ~ 3-10 gallons per minute of near-neutral thermal water. Trees within 4 meters of the lineament were dead and were being slowly combusted. Porkchop Geyser in Norris' Back Basin had been dormant since it exploded in 1989, littering the nearby area with boulders up to over 1 m in diameter. Since that time, its water had remained well below the boiling temperature of water. From 1 April through 1 July `03, the temperature of waters in Porkchop's vent increased continuously from 67° to 88° C. Each Summer, Norris' Back Basin experiences an "annual disturbance" where individual hot springs and geysers typically show anomalous boiling, and have measurable increases in turbidity, acidity and SO4/Cl ratios. The disturbance has been linked to depressurization of the hydrothermal system as the hydrostatic pressure of the snowmelt-fed groundwater table wanes each summer. This year, the "Norris disturbance" is estimated to have begun on 11 July 2003,when pronounced changes were noted, including thermal pools that were boiled to dryness (e.g., Pearl Geyser), creating fumaroles. Porkchop Geyser erupted for the first time since 1989 on 16 July. New mud pots formed along the Back Basin Trail and increased ground temperatures were noted over an 500 x 300 m area. Park staff noted temperatures up to 94° C at 1 cm beneath the ground surface in areas that were previously cool. Vegetation in the area immediately died and began to break down due to the high temperatures. Yellowstone National Park closed the Back Basin Trail to all visitor travel on 22 July 2003. During the first week of August 2003, the Yellowstone Volcano Observatory installed a temporary monitoring network in the Norris Geyser Basin. University of Utah staff, with equipment and personnel made available by IRIS, UNAVCO, USGS and YNP, installed seven broadband seismometers and five continuous GPS receivers. In addition, YNP deployed a series of temperature data-loggers to record changes in flow from thermal features within the Norris Back Basin. The network is intended to identify ground motions associated with fluid flow within the geyser basin that may accompany eruptions of geysers, boiling episodes or events precursory to hydrothermal explosions. The monitoring network will remain operational for between four and twelve weeks.
Hetem, Robyn S; Mitchell, Duncan; de Witt, Brenda A; Fick, Linda G; Maloney, Shane K; Meyer, Leith C R; Fuller, Andrea
2018-05-31
As one of the few felids that is predominantly diurnal, cheetahs (Acinonyx jubatus Von Schreber, 1775) can be exposed to high heat loads in their natural habitat. Little is known about long-term patterns of body temperature and activity (including hunting) in cheetahs because long-term concurrent measurements of body temperature and activity never have been reported for cheetahs, or indeed for any free-living felid. We report here body temperature and locomotor activity measured with implanted data loggers over seven months in five free-living cheetahs in Namibia. Air temperature ranged from a maximum of 39ºC in summer to -2ºC in winter. Cheetahs had higher (∼0.4 ºC) maximum 24h body temperatures, later acrophase (∼1 h), with larger fluctuations in the range of the 24h body temperature rhythm (∼0.4 ºC) during a hot-dry period than during a cool-dry period, but maintained homeothermy irrespective of the climatic conditions. As ambient temperatures increased, the cheetahs shifted from a diurnal to a crepuscular activity pattern, with reduced activity between 9:00 and 15:00 and increased nocturnal activity. The timing of hunts followed the general pattern of activity; the cheetahs hunted when they were on the move. Cheetahs hunted if an opportunity presented itself, on occasion they hunted in the midday heat or in total darkness (new moon). Biologging revealed insights into cheetah biology that are not accessible by traditional observer-based techniques. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Tagliarolo, Morgana; McQuaid, Christopher D.
2016-01-01
Attempts to predict the response of species to long-term environmental change are generally based on extrapolations from laboratory experiments that inevitably simplify the complex interacting effects that occur in the field. We recorded heart rates of two genetic lineages of the brown mussel Perna perna over a full tidal cycle in-situ at two different sites in order to evaluate the cardiac responses of the two genetic lineages present on the South African coast to temperature and the immersion/emersion cycle. “Robomussel” temperature loggers were used to monitor thermal conditions at the two sites over one year. Comparison with live animals showed that robomussels provided a good estimate of mussel body temperatures. A significant difference in estimated body temperatures was observed between the sites and the results showed that, under natural conditions, temperatures regularly approach or exceed the thermal limits of P. perna identified in the laboratory. The two P. perna lineages showed similar tidal and diel patterns of heart rate, with higher cardiac activity during daytime immersion and minimal values during daytime emersion. Comparison of the heart rates measured in the field with data previously measured in the laboratory indicates that laboratory results seriously underestimate heart rate activity, by as much as 75%, especially during immersion. Unexpectedly, field estimates of body temperatures indicated an ability to tolerate temperatures considered lethal on the basis of laboratory measurements. This suggests that the interaction of abiotic conditions in the field does not necessarily raise vulnerability to high temperatures. PMID:26840775
Thermal fluctuation within nests and predicted sex ratio of Morelet's Crocodile.
Escobedo-Galván, Armando H; López-Luna, Marco A; Cupul-Magaña, Fabio G
2016-05-01
Understanding the interplay between thermal variations and sex ratio in reptiles with temperature-dependent sex determination is the first step for developing long-term conservation strategies. In case of crocodilians, the information is fragmentary and insufficient for establishing a general framework to consider how thermal fluctuation influence sex determination under natural conditions. The main goal of this study was to analyze thermal variation in nests of Crocodylus moreletii and to discuss the potential implications for predicting offspring sex ratio. The study was carried out at the Centro de Estudios Tecnológicos del Mar N° 2 and at the Sistemas Productivos Cocodrilo, Campeche, Mexico. Data was collected in the nesting season of Morelet's Crocodiles during three consecutive seasons (2007-2009). Thermal fluctuations for multiple areas of the nest chamber were registered by data loggers. We calculate the constant temperature equivalent based on thermal profiles among nests to assess whether there are differences between the nest temperature and its equivalent to constant temperature. We observed that mean nest temperature was only different among nests, while daily thermal fluctuations vary depending on the depth position within the nest chamber, years and nests. The constant temperature equivalent was different among and within nests, but not among survey years. We observed differences between constant temperature equivalent and mean nest temperature both at the top and in the middle of the nest cavities, but were not significantly different at the bottom of nest cavities. Our results enable examine and discuss the relevance of daily thermal fluctuations to predict sex ratio of the Morelet's Crocodile. Copyright © 2016 Elsevier Ltd. All rights reserved.
Deforestation: risk of sex ratio distortion in hawksbill sea turtles.
Kamel, Stephanie Jill; Mrosovsky, N
2006-06-01
Phenotypic sex in sea turtles is determined by nest incubation temperatures, with warmer temperatures producing females and cooler temperatures producing males. The common finding of highly skewed female-biased hatchling sex ratios in sea turtle populations could have serious repercussions for the long-term survival of these species and prompted us to examine the thermal profile of a relatively pristine hawksbill nesting beach in Guadeloupe, French West Indies. Data loggers placed at nest depth revealed that temperatures in the forested areas were significantly cooler than temperatures in the more open, deforested areas. Using these temperatures as a predictor of sex ratio, we were able to assess the relative contributions of the different beach zones to the primary sex ratio: significantly more males were likely to be produced in the forested areas. Coastal forests are therefore important male-producing areas for the hawksbill sea turtle, and this has urgent conservation implications. On Guadeloupe, as on many Caribbean islands, deforestation rates are high and show few signs of slowing, as there is continual pressure to develop beachfront areas. The destruction of coastal forest could have serious consequences both in terms of local nesting behavior and of regional demography through the effects on population sex ratios. Human alterations to nesting habitat in other reptile taxa have been shown to modify the thermal properties of nest sites in ways that can disrupt their ecology by allowing parasite transmission, increasing vulnerability to climate change, or rendering existing habitat unsuitable.
Using UAVs to Conduct Student-led Research Projects
NASA Astrophysics Data System (ADS)
Olds, S. E.; Lewis, P. M., Jr.
2016-12-01
Recreational drones can inspire students to initiate research projects. These "toys" have a low cost (<$100), low weight (< 250 g, so do not require FAA registration), and an ability to carry small instrument packages, making them an ideal platform for conducting innovative investigations. This session describes an initiative by the Federation of Earth Science Information Partners (ESIP) Education Committee to compile and distribute a free e-book that will encourage learners to use drones for science investigations. Our goal is to inspire learners to use UAVs to carry scientific instruments and/or capture imagery to conduct local-scale investigations. Experiments such as discovering their vehicle's maximum payload help learners understand what sensors they can use (or build) to conduct research. The e-book will encourage learners to practice UAV civility and safety through a pre-flight checklist and flying guidelines, and to consider science objectives and flight team roles in performing investigations. Activities also advocate for robust data and metadata-collection practices. Suggested activities encompass repeat photography investigations as well as engineering design skills such as designing a camera mount to obtain nadir or oblique imagery. Learners can also move to more sophisticated research using photogrammetric skills such as taking overlapping photographs to create 3D structure from motion (SfM) models. To encourage the use of onboard sensors, the team worked with an engineer to build a 33-gram prototype environmental logger called SABEL (Shelley [Olds] and Bob [Ellis]'s Environmental Logger). Assembled on an Arduino board, SABEL collects temperature, humidity, and GPS position. This presentation will provide examples of student-led investigations, instructions for building the SABEL sensor package, and the status of the new e-book compilation of student-focused activities using recreational drones to pursue science, math, engineering, and technology research investigations.
Williams, Paul D; Paixão, Gustavo
2018-04-19
Livestock vaccines (LV) are often stored on-farm, in a refrigerator (fridge), prior to use and little is documented about the storage conditions during this period. As the quality of a vaccine can be impaired by storage at an incorrect temperature, the present study aimed to evaluate the on-farm performance of farm fridges to maintain the correct storage temperature. From January to August 2014, temperature data loggers were placed on selected farms fridges used to store LV (n = 20) in South-West England. Temperature recording data was available from 17 of the 20 farms. Fifty-nine percent of farm fridges had at least one temperature recording above 8 °C, 53% had at least one recording below 2 °C and 41% at or below 0 °C. Internal fridge temperatures attained 24 °C and dropped to - 12 °C as an absolute maximum and minimum respectively. Fridges tested spent an average of 16% of the total time recorded above 8 °C. Time of the year significantly influenced the percentage of time above 8 °C. External and internal temperatures were found to be positively correlated (p < 0.001). Statistical significant differences in internal and external temperatures were found between March and August. The majority of fridges in this study would have failed to keep any stored LV within the recommended storage temperature range. If LV are going to be stored on-farm prior to use, then urgent improvements in this part of the cold-chain are required in order to insure vaccine efficacy is not compromised.
Finke, G R; Bozinovic, F; Navarrete, S A
2009-01-01
Developing mechanistic models to predict an organism's body temperature facilitates the study of physiological stresses caused by extreme climatic conditions the species might have faced in the past or making predictions about changes to come in the near future. Because the models combine empirical observation of different climatic variables with essential morphological attributes of the species, it is possible to examine specific aspects of predicted climatic changes. Here, we develop a model for the competitively dominant intertidal mussel Perumytilus purpuratus that estimates body temperature on the basis of meteorological and tidal data with an average difference (+/-SE) of 0.410 degrees +/- 0.0315 degrees C in comparison with a field-deployed temperature logger. Modeled body temperatures of P. purpuratus in central Chile regularly exceeded 30 degrees C in summer months, and values as high as 38 degrees C were found. These results suggest that the temperatures reached by mussels in the intertidal zone in central Chile are not sufficiently high to induce significant mortality on adults of this species; however, because body temperatures >40 degrees C can be lethal for this species, sublethal effects on physiological performance warrant further investigation. Body temperatures of mussels increased sigmoidally with increasing tidal height. Body temperatures of individuals from approximately 70% of the tidal range leveled off and did not increase any further with increasing tidal height. Finally, body size played an important role in determining body temperature. A hypothetical 5-cm-long mussel (only 1 cm longer than mussels found in nature) did reach potentially lethal body temperatures, suggesting that the biophysical environment may play a role in limiting the size of this small species.
NASA Astrophysics Data System (ADS)
Bird, B. M.; Devitt, D.
2012-12-01
Cold air drainage flows are a naturally occurring physical process of mountain systems. Plant communities that exist in cold air drainage basins respond to these localized cold air trends, and have been shown to be decoupled from larger global climate weather systems. The assumption that air temperature decreases with altitude is violated within these systems and climate model results based on this assumption would ultimately be inaccurate. In arid regions, high radiation loads lead to significant long wave radiation being emitted from the ground later in the day. As incoming radiation ceases, the surface very quickly loses energy through radiative processes, leading to surface inversions and enhanced cold air drainage opportunities. This study is being conducted in the Mojave desert on Sheep Mountain located between sites 3 and 4 of the NSF EPSCoR network. Monitoring of cold air drainage was initiated in September of 2011within a narrow ravine located between the 2164 and 2350 meter elevation. We have installed 25 towers (5 towers per location situated at the central low point in a ravine and at equal distances up the sides of the ravine on both the N and S facing slopes) to assess air temperatures from 0.1 meters to a height of 3 meters at 25m intervals. Our goal is to better understand the connection between cold air movement and plant physiological response. The species monitored in this study include: Pinus ponderosa (common name: Ponderosa Pine), Pinus pinyon (Pinyon Pine), Juniperus osteosperma (Utah juniper), Cercocarpus intricatus (Mountain Mahogany) and Symphoricarpos (snowberry). Hourly air temperature measurements within the wash are being captured from 100 ibuttons placed within PVC solar radiation shields. We are also developing a modeling approach to assess the three dimensional movement of cold air over time by incorporating wind vectors captured from 5 2D sonic anemometers. Wind velocities will be paired with air temperatures to better understand the thermal dynamics of cold air drainage. Granier probes were installed in the five test species to monitor transpirational flow relative to cold air movement. Mid day soil - plant - water measurements are also being taken on a monthly basis during the growing season at all locations. Measurements include: leaf xylem water potential, stomata conductance, chlorophyll index readings, canopy minus ambient temperatures and surface soil moisture contents. To date the monitoring system has revealed cold air drainage occurring during periods of every month. We will report the physiological response of the five plant species, with emphasis on assessing the linkages with cold air movement.
NASA Astrophysics Data System (ADS)
Garthe, Stefan; Montevecchi, William A.; Davoren, Gail K.
2007-02-01
We applied data loggers (temperature-depth and GPS-temperature-depth) on individual birds in combination with dietary sampling and a vessel survey of prey availability to assess the foraging behaviour of northern gannets ( Sula bassana, Linnaeus 1758) in a low-Arctic ecosystem in the NW Atlantic. We demonstrate that the gannets foraged almost exclusively on inshore and coastal aggregations of capelin. There was a strong correspondence between the distributions of capelin and foraging gannets, and gannets exhibited persistence in successive foraging trips to the same foraging areas. The diving activity of gannets was highest during the early morning and evening, when capelin are known to be primarily available in the upper water column. Most of the gannets dive depths were less than 5 m. Flight speeds recorded by GPS were 9% higher than those estimated by previous methods and were shown to benefit from tail wind. This study shows how a combination of ship-based surveys and individually tagged birds can help understanding predator-prey intersection in a three-dimensional space in the marine environment.
Godfrey, A; Culhane, K M; Lyons, G M
2007-10-01
The aim of this study was to assess the accuracy of the 'activPAL Professional' physical activity logger by comparing its output to that of a proven discrete accelerometer-based activity monitor during extended measurements on healthy subjects while performing activities of daily living (ADL). Ten healthy adults, with unrestricted mobility, wore both the activPAL and the discrete dual accelerometer (Analog Devices ADXL202)-based activity monitor that recorded in synchronization with each other. The accelerometer derived data were then compared to that generated by the activPAL and a complete statistical and error analysis was performed using a Matlab program. This program determined trunk and thigh inclination angles to distinguish between sitting/lying, standing and stepping for the discrete accelerometer device and amount of time spent on each activity. Analysis was performed on a second-by-second basis and then categorized at 15s intervals in direct comparison with the activPAL generated data. Of the total time monitored (approximately 60 h) the detection accuracies for static and dynamic activities were approximately 98%. In a population of healthy adults, the data obtained from the activPAL Professional physical activity logger for both static and dynamic activities showed a close match to a proven discrete accelerometer data with an offset of approximately 2% between the two systems.
On the frequency response of a Wenglor particle-counting system for aeolian transport measurements
NASA Astrophysics Data System (ADS)
Bauer, Bernard O.; Davidson-Arnott, Robin G. D.; Hilton, Michael J.; Fraser, Douglas
2018-06-01
A commonly deployed particle-counting system for aeolian saltation flux, consisting of a Wenglor fork sensor and an Onset Hobo Pulse Input Adapter linked to an Onset Hobo Energy Logger Pro data logger, was tested for frequency response. The Wenglor fork sensor is an optical gate device that has very fast switching capacity that can accommodate the time of flight of saltating sand particles through the sensing volume with the exception of very fine sand or silt and very quickly moving particles. The Pulse Input Adapter, in contrast, imposes limitations on the frequency response of the system. The manufacturer of the pulse adapter specifies an upper limit of 120 Hz, although bench tests with an electronic pulse generator indicate that the frequency response of the Pulse Input Adapter, in isolation, is excellent up to 3000 Hz, with only small error (less than 1.6%) due to under-counting during data transfer intervals. A mechanical test of the integrated system (fork sensor, pulse input adapter, and data logger) demonstrates excellent performance up to about 700 Hz (less than 2% error), but significant under-counting above 1000 Hz for unknown reasons. This specific particle-counting system therefore has a frequency response that is well suited for investigation of the dynamics of aeolian saltation as typically encountered in most field conditions on coastal beaches with the exception of extreme wind events and very small particle sizes.
Design and Deployment of a General Purpose, Open Source LoRa to Wi-Fi Hub and Data Logger
NASA Astrophysics Data System (ADS)
DeBell, T. C.; Udell, C.; Kwon, M.; Selker, J. S.; Lopez Alcala, J. M.
2017-12-01
Methods and technologies facilitating internet connectivity and near-real-time status updates for in site environmental sensor data are of increasing interest in Earth Science. However, Open Source, Do-It-Yourself technologies that enable plug and play functionality for web-connected sensors and devices remain largely inaccessible for typical researchers in our community. The Openly Published Environmental Sensing Lab at Oregon State University (OPEnS Lab) constructed an Open Source 900 MHz Long Range Radio (LoRa) receiver hub with SD card data logger, Ethernet and Wi-Fi shield, and 3D printed enclosure that dynamically uploads transmissions from multiple wirelessly-connected environmental sensing devices. Data transmissions may be received from devices up to 20km away. The hub time-stamps, saves to SD card, and uploads all transmissions to a Google Drive spreadsheet to be accessed in near-real-time by researchers and GeoVisualization applications (such as Arc GIS) for access, visualization, and analysis. This research expands the possibilities of scientific observation of our Earth, transforming the technology, methods, and culture by combining open-source development and cutting edge technology. This poster details our methods and evaluates the application of using 3D printing, Arduino Integrated Development Environment (IDE), Adafruit's Open-Hardware Feather development boards, and the WIZNET5500 Ethernet shield for designing this open-source, general purpose LoRa to Wi-Fi data logger.
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
Vatland, Shane J.; Gresswell, Robert E.; Poole, Geoffrey C.
2015-01-01
Accurately quantifying stream thermal regimes can be challenging because stream temperatures are often spatially and temporally heterogeneous. In this study, we present a novel modeling framework that combines stream temperature data sets that are continuous in either space or time. Specifically, we merged the fine spatial resolution of thermal infrared (TIR) imagery with hourly data from 10 stationary temperature loggers in a 100 km portion of the Big Hole River, MT, USA. This combination allowed us to estimate summer thermal conditions at a relatively fine spatial resolution (every 100 m of stream length) over a large extent of stream (100 km of stream) during during the warmest part of the summer. Rigorous evaluation, including internal validation, external validation with spatially continuous instream temperature measurements collected from a Langrangian frame of reference, and sensitivity analyses, suggests the model was capable of accurately estimating longitudinal patterns in summer stream temperatures for this system Results revealed considerable spatial and temporal heterogeneity in summer stream temperatures and highlighted the value of assessing thermal regimes at relatively fine spatial and temporal scales. Preserving spatial and temporal variability and structure in abiotic stream data provides a critical foundation for understanding the dynamic, multiscale habitat needs of mobile stream organisms. Similarly, enhanced understanding of spatial and temporal variation in dynamic water quality attributes, including temporal sequence and spatial arrangement, can guide strategic placement of monitoring equipment that will subsequently capture variation in environmental conditions directly pertinent to research and management objectives.
NASA Astrophysics Data System (ADS)
Gordeev, V. F.; Malyshkov, S. Yu.; Botygin, I. A.; Sherstnev, V. S.; Sherstneva, A. I.
2017-11-01
The general trend of modern ecological geophysics is changing priorities towards rapid assessment, management and prediction of ecological and engineering soil stability as well as developing brand new geophysical technologies. The article describes researches conducted by using multi-canal geophysical logger MGR-01 (developed by IMCES SB RAS), which allows to measure flux density of very low-frequency electromagnetic radiation. It is shown that natural pulsed electromagnetic fields of the earthen lithosphere can be a source of new information on Earth's crust and processes in it, including earthquakes. The device is intended for logging electromagnetic processes in Earth's crust, geophysical exploration, finding structural and lithological inhomogeneities, monitoring the geodynamic movement of Earth's crust, express assessment of seismic hazards. The data is gathered automatically from observation point network in Siberia
Flight experience with lightweight, low-power miniaturized instrumentation systems
NASA Technical Reports Server (NTRS)
Hamory, Philip J.; Murray, James E.
1992-01-01
Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this paper is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. The paper will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. The paper also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. Finally, future plans for these systems will be discussed.
NASA Astrophysics Data System (ADS)
Yamamoto, Masa-yuki; Kakinami, Yoshihiro; Kono, Hiroki
In Japan, the high altitude balloon for scientific observation has been continuously launched by JAXA. The balloon has a possibility to reach 50 km altitude without tight environmental condition for onboard equipments, operating with a cost lower than sounding rockets, however, development of the large-scale scientific observation balloons by university laboratories is still difficult. Being coupled with recent improvement of semiconductor sensors, laboratory-basis balloon experiments using small weather balloons has been becoming easily in these years. Owing to an advantage of wide land fields in continental regions, the launch of such small balloons has become to be carried out many times especially in continental countries (e.g. Near Space Ventures, Inc., 2013). Although the balloon is very small as its diameter of 6 feet, excluding its extra buoyancy and the weight of the balloon itself, it is expected that about 2 kg loading capacity is remained for payloads to send it up to about 35 km altitude. However, operation of such balloons in Japan is not in general because precise prediction of a landing area of the payload is difficult, thus high-risk situation for balloon releases is remained. In this study, we aim to achieve practical engineering experiments of weather balloons in Japan to be used for scientific observation within university laboratory level as an educational context. Here we report an approach of developing many devices for a small tethered balloon currently in progress. We evaluated an accuracy of altitude measurement by using a laboratory developed altitude data logger system that consists of a GPS-module and a barometric altimeter. Diameter of the balloon was about 1.4 m. Being fulfilled with about 1440 L helium, it produced buoyancy of about 15.7 N. Taking into account of total weight including the mooring equipments, available payload mass becomes to be about 1100 g. Applying an advantage of a 3D printer of FDM (Fused Deposition Modeling) method with a 3DCAD design software, we designed and manufactured a camera-platform type antenna rotator that automatically track the balloon direction based on the received GPS data as a balloon operation system on ground with automatic controlling software for the tracking system. In order to develop a future telemetry system onboard a small weather balloon, we have performed an onboard data logger system. In this presentation, system configuration of the automatic tracking system will be introduced more in detail. The telemetry system onboard the small balloon is currently under development. We have a plan to send the measured GPS coordinates, temperature, pressure, and humidity data detected by the onboard sensors to ground. A monitoring camera, a 3-axes accelerometer, geomagnetic azimuth measurement, and power monitoring were added to the developed data logger system. The acquired data will be stored in an SD card aboard as well as transmitted to the ground. Using a vacuum chamber with a pressure sensors and a constant-temperature reservoir in laboratory, environmental tests were operated. In this presentation, introducing the data obtained through the development of a prototype balloon system, our recent results and problems will be discussed.
Temperature rises during application of Er:YAG laser under different primary dentin thicknesses.
Hubbezoglu, Ihsan; Unal, Murat; Zan, Recai; Hurmuzlu, Feridun
2013-05-01
The present study investigated the effects of the Er:YAG laser's different pulse repetition rates on temperature rise under various primary dentin thicknesses. The Er:YAG laser can be used for restorative approaches in clinics and is used to treat dental caries. There are some reports that explain the temperature rise effect of the Er:YAG laser. Recently, the Er:YAG laser has been found to play an important role in temperature rises during the application on dentin. Caries-free primary mandibular molars were prepared to obtain dentin discs with 0.5, 1, 1.5, and 2 mm thicknesses (n=10). These discs were placed between the Teflon mold cylinders of a temperature test apparatus. We preferred three pulse repetition rates of 10, 15, and 20 Hz with an energy density of 12.7 J/cm2 and a 230 μs pulse duration. All dentin discs were irradiated for 30 sec by the Er:YAG laser. Temperature rises were recorded using an L-type thermocouple and universal data loggers/scanners (E-680, Elimko Co., Turkey). Data were analyzed by two-way ANOVA and Tukey tests. Whereas the lowest temperature rise (0.44±0.09 °C) was measured from a 10 Hz pulse repetition rate at a dentin thickness of 2 mm, the highest temperature rise (3.86±0.43 °C) was measured from a 20 Hz pulse repetition rate at a 0.5 mm dentin thickness. Temperature rise did not reach critical value for pulpal injury in any primary dentin thicknesses irradiated by a high repetition rate of the Er:YAG laser.
Ogle, G D; Abdullah, M; Mason, D; Januszewski, A S; Besançon, S
2016-11-01
Insulin loses potency when stored at high temperatures. Various clay pots part-filled with water, and other evaporative cooling devices, are used in less-resourced countries when home refrigeration is unavailable. This study examined the cooling efficacy of such devices. Thirteen devices used in Sudan, Ethiopia, Tanzania, Mali, India, Pakistan and Haiti (10 clay pots, a goat skin, a vegetable gourd and a bucket filled with wet sand), and two identical commercially manufactured cooling wallets were compared. Devices were maintained according to local instructions. Internal and ambient temperature and ambient humidity were measured by electronic loggers every 5 min in Khartoum (88 h), and, for the two Malian pots, in Bamako (84 h). Cooling efficacy was assessed by average absolute temperature difference (internal vs. ambient), and % maximal possible evaporative cooling (allowing for humidity). During the study period, mean ambient temperature and humidity were 31.0°C and 32.0% in Khartoum and 32.9°C and 39.8% in Bamako. All devices reduced the temperature (P < 0.001) with a mean (sd) reduction from 2.7 ± 0.5°C to 8.3 ± 1.0°C, depending on the device. When expressed as % maximal cooling, device efficacy ranged from 20.5% to 71.3%. On cluster analysis, the most efficacious devices were the goat skin, two clay pots (from Ethiopia and Sudan) and the suspended cooling wallet. Low-cost devices used in less-resourced countries reduce storage temperatures. With more efficacious devices, average temperatures at or close to standard room temperature (20-25°C) can be achieved, even in hot climates. All devices are more efficacious at lower humidity. Further studies are needed on insulin stability to determine when these devices are necessary. © 2016 Diabetes UK.
Temperature Rise on the Plugger Surface of 2 Commercially Available Gutta-percha Heating Devices.
Dimopoulos, Fotis; Dervenis, Konstantinos; Gogos, Christos; Lambrianidis, Theodoros
2017-11-01
The objective of this study was to examine the temperature rise on the plugger surface of 2 commercially available gutta-percha heating devices: the System B (Kerr Dental, Amersfoort, The Netherlands) and the System B Cordless Pack Unit (Kerr Dental). Temperature changes were recorded by a Thermocouple Data Logger device (Pico Technology Ltd, St Neots, UK) and 2 thermocouples: the first to record the temperature on the plugger surface in an isolated polytetrafluoroethylene system and the second to record the base temperature of the environment. The gutta-percha heating devices studied were System B with F, FM, M, and ML pluggers set at the "use" position, "touch" mode, temperature of 200°C, and a power setting of 10 and the System B Cordless Pack Unit with the FM plugger set at low power. Two variables were extracted from the collected temperature data: the temperature on the plugger surface 10 seconds after activating each gutta-percha heating device (θ 10 ) and the time required to reach 60°C (t 60 ). The differences between the pluggers over those 2 variables were investigated using analysis of variance and the Tukey B test for post hoc comparisons (P < .05). The mean θ 10 for all pluggers ranged between 73°C and 87°C. The mean t 60 for all pluggers ranged between 1.3 and 3.3 seconds. No clinically significant differences between the pluggers were observed. The gutta-percha heating devices tested achieve maximum temperatures lower than 94°C and are capable of gutta-percha phase transformation within approximately 4 seconds of activation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Comfort in High-Performance Homes in a Hot-Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, A.; Beach, R.
2016-01-22
"9IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature alsomore » was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees F for 5% of the time. For 80% of the time, the rooms in each house were within 4 degrees F of each other. Additionally, the impact of system runtime on comfort is discussed. Finally, measurements made at the thermostat were used to better understand the occupant operation of each cooling system's thermostat setpoint. Builders were questioned on their perceived impact of offering a comfort and performance guarantee. Their feedback, which generally indicates a positive perception, has been summarized in the report.« less
Brinkhoff, James; Hornbuckle, John; Dowling, Thomas
2017-12-26
Multisensor capacitance probes (MCPs) have traditionally been used for soil moisture monitoring and irrigation scheduling. This paper presents a new application of these probes, namely the simultaneous monitoring of ponded water level, soil moisture, and temperature profile, conditions which are particularly important for rice crops in temperate growing regions and for rice grown with prolonged periods of drying. WiFi-based loggers are used to concurrently collect the data from the MCPs and ultrasonic distance sensors (giving an independent reading of water depth). Models are fit to MCP water depth vs volumetric water content (VWC) characteristics from laboratory measurements, variability from probe-to-probe is assessed, and the methodology is verified using measurements from a rice field throughout a growing season. The root-mean-squared error of the water depth calculated from MCP VWC over the rice growing season was 6.6 mm. MCPs are used to simultaneously monitor ponded water depth, soil moisture content when ponded water is drained, and temperatures in root, water, crop and ambient zones. The insulation effect of ponded water against cold-temperature effects is demonstrated with low and high water levels. The developed approach offers advantages in gaining the full soil-plant-atmosphere continuum in a single robust sensor.
Microprocessors: Laboratory Simulation of Industrial Control Applications.
ERIC Educational Resources Information Center
Gedeon, David V.
1981-01-01
Describes a course to make technical managers more aware of computer technology and how data loggers, programmable controllers, and larger computer systems interact in a hierarchical configuration of manufacturing process control. (SK)
Climate change at upper treeline: How do trees on the edge react to increasing temperatures?
NASA Astrophysics Data System (ADS)
Jochner, Matthias; Bugmann, Harald; Nötzli, Magdalena; Bigler, Christof
2017-04-01
Treeline ecotones are thought to be particularly sensitive to climate warming, and an alteration of their growth conditions may have important implications for the ecosystem services they supply in mountain regions. We use a novel approach to quantify effects of a changing climate on tree growth, using case studies in the European Alps. We compiled tree-ring data from almost 600 trees of four species at treeline in three climate regions of Switzerland. Temperature loggers installed along transects provided data for a precise interpolation of temperatures experienced by the sampled trees. To assess the influence of temperature on annual growth, we used linear mixed-effects models, allowing us to quantify effect sizes and to account for between-tree growth variability. After removing biological growth trends, we isolated temporal trends of ring-width indices. Furthermore, we fitted non-linear regression models to radial growth rates of individual years with temperature and tree age as predicting covariates for a fine-scale investigation of the temperature dependency of tree growth. For all species, climate-growth linear mixed-effects models indicated strong positive responses of ring-width indices to temperature in early summer and previous year's autumn, featuring considerable between-tree variability. All species showed positive ring-width index trends at treeline but different interactions with elevation: Larix decidua exhibited a declining ring-width index trend with decreasing elevation, whereas Picea abies, Pinus cembra and Pinus mugo showed increasing and/or stable trends. Not only reflected our findings the effects of ameliorated growth conditions, they might have also revealed suspected negative and positive feedbacks of climate change on growth, and increased the knowledge about the functional form and parameterization of the temperature dependency of tree growth.
NASA Astrophysics Data System (ADS)
Angel, E.; Ortega, S.; Gonzalez-Duque, D.; Ruiz-Carrascal, D.
2016-12-01
Geothermal energy production depends on the difference between air temperature and the geothermal fluid temperature. The latter remains approximately constant over time, so the power generation varies according to local atmospheric conditions. Projected changes in near-surface air temperatures in the upper levels of the tropical belt are likely to exceed the projected temperature anomalies across many other latitudes, which implies that geothermal plants located in these regions may be affected, reducing their energy output. This study focuses on a hypothetical geothermal power plant, located in the headwaters of the Claro River watershed, a key high-altitude basin in Los Nevados Natural Park, on the El Ruiz-Tolima volcanic massif, in the Colombian Central Andes, a region with a known geothermal potential. Four different Atmospheric General Circulation Models where used to project temperature anomalies for the 2040-2069 prospective period. Their simulation outputs were merged in a differentially-weighted multi-model ensemble, whose weighting factors were defined according to the capability of individual models to reproduce ground truth data from a set of digital data-loggers installed in the basin since 2008 and from weather stations gathering climatic variables since the early 50s. Projected anomalies were computed for each of the Representative Concentration Pathways defined by the IPCC Fifth Assessment Report in the studied region. These climate change projections indicate that air temperatures will likely reach positive anomalies in the range +1.27 ºC to +3.47 ºC, with a mean value of +2.18 ºC. Under these conditions, the annual energy output declines roughly 1% per each degree of increase in near-surface temperature. These results must be taken into account in geothermal project evaluations in the region.
Westhoff, Jacob T.; Paukert, Craig P.
2014-01-01
Climate change is predicted to increase water temperatures in many lotic systems, but little is known about how changes in air temperature affect lotic systems heavily influenced by groundwater. Our objectives were to document spatial variation in temperature for spring-fed Ozark streams in Southern Missouri USA, create a spatially explicit model of mean daily water temperature, and use downscaled climate models to predict the number of days meeting suitable stream temperature for three aquatic species of concern to conservation and management. Longitudinal temperature transects and stationary temperature loggers were used in the Current and Jacks Fork Rivers during 2012 to determine spatial and temporal variability of water temperature. Groundwater spring influence affected river water temperatures in both winter and summer, but springs that contributed less than 5% of the main stem discharge did not affect river temperatures beyond a few hundred meters downstream. A multiple regression model using variables related to season, mean daily air temperature, and a spatial influence factor (metric to account for groundwater influence) was a strong predictor of mean daily water temperature (r2 = 0.98; RMSE = 0.82). Data from two downscaled climate simulations under the A2 emissions scenario were used to predict daily water temperatures for time steps of 1995, 2040, 2060, and 2080. By 2080, peak numbers of optimal growth temperature days for smallmouth bass are expected to shift to areas with more spring influence, largemouth bass are expected to experience more optimal growth days (21 – 317% increase) regardless of spring influence, and Ozark hellbenders may experience a reduction in the number of optimal growth days in areas with the highest spring influence. Our results provide a framework for assessing fine-scale (10 s m) thermal heterogeneity and predict shifts in thermal conditions at the watershed and reach scale. PMID:25356982
Hetem, Robyn S; de Witt, Brenda A; Fick, Linda G; Fuller, Andrea; Kerley, Graham I H; Meyer, Leith C R; Mitchell, Duncan; Maloney, Shane K
2009-03-01
Using intra-abdominal miniature data loggers, we measured core body temperature in female springbok (Antidorcas marsupialis) of three colour morphs (black, normal and white), free-living in the Karoo, South Africa, for one year. During winter, white springbok displayed lower daily minimum body temperatures (37.4+/-0.5 degrees C), than both black (38.1+/-0.3 degrees C) and normal (38.0+/-0.6 degrees C) springbok. During spring, black springbok displayed higher daily maximum body temperatures (40.7+/-0.1 degrees C) than both white (40.2+/-0.2 degrees C) and normal (40.2+/-0.2 degrees C) springbok. These high maximum body temperatures were associated with larger daily amplitudes of nychthemeral rhythm of body temperature (2.0+/-0.2 degrees C), than that of white (1.6+/-0.1 degrees C) and normal (1.7+/-0.2 degrees C) springbok. Biophysical properties of sample springbok pelts were consistent with these patterns, as the black springbok pelt showed lower reflectance in the visible spectral range, and higher heat load from simulated solar radiation, than did the pelts of the other two springbok. Black springbok had lower diurnal activity in winter, consistent with them having to forage less because their metabolic cost of homeothermy was lower, but were disadvantaged in hot periods. White springbok, by contrast, were more protected from solar heat load, but potentially less able to meet the energy cost of homeothermy in winter. Thus energy considerations may underlie the rarity of the springbok colour morphs.
76 FR 44306 - Endangered Species; File No. 16146
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-25
.... Of the 160, 20 also would be tagged with satellite tags and data loggers (epoxy attachments) and acoustic transmitters (epoxy or drill carapace and attach with wire). All 20 would not necessarily be...
Diving Simulation concerning Adélie Penguin
NASA Astrophysics Data System (ADS)
Ito, Shinichiro; Harada, Masanori
Penguins are sea birds that swim using lift and drag forces by flapping their wings like other birds. Although diving data can be obtained using a micro-data logger which has improved in recent years, all the necessary diving conditions for analysis cannot be acquired. In order to determine all these hard-to-get conditions, the posture and lift and drag forces of penguins were theoretically calculated by the technique used in the analysis of the optimal flight path of aircrafts. In this calculation, the actual depth and speed of the dive of an Adélie penguin (Pygoscelis adeliae) were utilized. Then, the calculation result and experimental data were compared, and found to be in good agreement. Thus, it is fully possible to determine the actual conditions of dive by this calculation, even those that cannot be acquired using a data logger.
de Jong, Carol; Field, Hume; Tagtag, Anson; Hughes, Tom; Dechmann, Dina; Jayme, Sarah; Epstein, Jonathan H; Epstein, Jonathan; Smith, Craig; Santos, Imelda; Catbagan, Davinio; Lim, Mundita; Benigno, Carolyn; Daszak, Peter; Newman, Scott
2013-01-01
Species of Old World fruit-bats (family Pteropodidae) have been identified as the natural hosts of a number of novel and highly pathogenic viruses threatening livestock and human health. We used GPS data loggers to record the nocturnal foraging movements of Acerodon jubatus, the Golden-crowned flying fox in the Philippines to better understand the landscape utilisation of this iconic species, with the dual objectives of pre-empting disease emergence and supporting conservation management. Data loggers were deployed on eight of 54 A. jubatus (two males and six females) captured near Subic Bay on the Philippine island of Luzon between 22 November and 2 December 2010. Bodyweight ranged from 730 g to 1002 g, translating to a weight burden of 3-4% of bodyweight. Six of the eight loggers yielded useful data over 2-10 days, showing variability in the nature and range of individual bat movements. The majority of foraging locations were in closed forest and most were remote from evident human activity. Forty-six discrete foraging locations and five previously unrecorded roost locations were identified. Our findings indicate that foraging is not a random event, with the majority of bats exhibiting repetitious foraging movements night-to-night, that apparently intact forest provides the primary foraging resource, and that known roost locations substantially underestimate the true number (and location) of roosts. Our initial findings support policy and decision-making across perspectives including landscape management, species conservation, and potentially disease emergence.
Castle, Kevin T.; Weller, Theodore J.; Cryan, Paul M.; Hein, Cris D.; Schirmacher, Michael R.
2015-01-01
1. Determining the detailed movements of individual animals often requires them to carry tracking devices, but tracking broad-scale movement of small bats (< 30g) has been limited by transmitter technology and long-term attachment methods. This limitation inhibits our understanding of bat dispersal and migration, particularly in the context of emerging conservation issues like fatalities at wind turbines and diseases. 2. We tested a novel method of attaching lightweight global positioning system (GPS) tags and geolocating data loggers to small bats. We used monofilament, synthetic, absorbable sutures to secure GPS tags and data loggers to the skin of anesthetized big brown bats (Eptesicus fuscus) in Colorado and hoary bats (Lasiurus cinereus) in California. 3. GPS tags and data loggers were sutured to 17 bats in this study. Three tagged bats were recaptured seven months after initial deployment, with tags still attached; none of these bats showed ill effects from the tag. No severe injuries were apparent upon recapture of 6 additional bats that carried tags up to 26 days after attachment, however one of the bats exhibited skin chafing. 4. Use of absorbable sutures to affix small tracking devices seems to be a safe, effective method for studying movements of bats over multiple months, although additional testing is warranted. This new attachment method has the potential to quickly advance our understanding of small bats, particularly as more-sophisticated miniature tracking devices (e.g., satellite tags) become available.
Castle, Kevin T; Weller, Theodore J; Cryan, Paul M; Hein, Cris D; Schirmacher, Michael R
2015-07-01
Determining the detailed movements of individual animals often requires them to carry tracking devices, but tracking broad-scale movement of small bats (<30 g) has been limited by transmitter technology and long-term attachment methods. This limitation inhibits our understanding of bat dispersal and migration, particularly in the context of emerging conservation issues such as fatalities at wind turbines and diseases. We tested a novel method of attaching lightweight global positioning system (GPS) tags and geolocating data loggers to small bats. We used monofilament, synthetic, absorbable sutures to secure GPS tags and data loggers to the skin of anesthetized big brown bats (Eptesicus fuscus) in Colorado and hoary bats (Lasiurus cinereus) in California. GPS tags and data loggers were sutured to 17 bats in this study. Three tagged bats were recaptured 7 months after initial deployment, with tags still attached; none of these bats showed ill effects from the tag. No severe injuries were apparent upon recapture of 6 additional bats that carried tags up to 26 days after attachment; however, one of the bats exhibited skin chafing. Use of absorbable sutures to affix small tracking devices seems to be a safe, effective method for studying movements of bats over multiple months, although additional testing is warranted. This new attachment method has the potential to quickly advance our understanding of small bats, particularly as more sophisticated miniature tracking devices (e.g., satellite tags) become available.
UAV Applications in Hydrology: A Case Study in Gökova Basin, Muğla, Turkey
NASA Astrophysics Data System (ADS)
Kurtulus, B.; Sağır, Ç.; Erdem, G.; Avşar; Kurtuluş, D. F.; Tunca, E.; Le Coz, M.; Razack, M.
2016-12-01
Adopting new technologies to hydrogeological studies is quite seldom at the present time. In the near future, successfully applications of Unmanned Air Vehicle (UAV) and small data logging system will be expected to show positive impact by encouraging the innovative designs and uses of these systems to monitor hydrosystem changes in local-to-regional ecosystems. Understanding of hydrosystem using these devices and the prediction of global/local change impacts on it has one of the highest scientific and socio-economic importance in Mediterranean zone. This study is a part of an ERANETMED project title as "Groundwater Resilience to Climate Change and High Pressure within an IWRM Approach". The main aim is to use of different types of drone and loggers equipped with visible/multispectral/thermal cameras for monitoring karstic springs, lakes, rivers etc... The advantages of this study are the ease of field data acquiring, fast and safe measurement process without making any harm to karstic springs by using hazardous materials and implement hi-tech instruments in hydrogeology studies. Therefore, in this study producing high resolution spatial and temporal hydrodynamic and physicochemical data of karst springs are collected by using drone and loggers. The preliminary results of drone images, logger data analysis and the possible application use of drones in hydrogeology domain will be presented in this study. In this regard, we would like to thank TUBITAK & ERANETMED (Project No: 115Y843) and the project members.
NASA Astrophysics Data System (ADS)
Bates, Alan
2015-12-01
Instruments or digital meters with data values visible on a seven-segment display can easily be found in the physics lab. Examples include multimeters, sound level meters, Geiger-Müller counters and electromagnetic field meters, where the display is used to show numerical data. Such instruments, without the ability to connect to computers or data loggers, can measure and display data at a particular instant in time. The user should be present to read the display and to record the data. Unlike these digital meters, the sensor-data logger system has the advantage of automatically measuring and recording data at selectable sample rates over a desired sample time. The process of adding data logging features to a digital meter with a seven-segment display can be achieved with Seven Segment Optical Character Recognition (SSOCR) software. One might ask, why not just purchase a field meter with data logging features? They are relatively inexpensive, reliable, available online, and can be delivered within a few days. But then there is the challenge of making your own instrument, the excitement of implementing a design, the pleasure of experiencing an entire process from concept to product, and the satisfaction of avoiding costs by taking advantage of available technology. This experiment makes use of an electromagnetic field meter with a seven-segment liquid crystal display to measure background electromagnetic field intensity. Images of the meter display are automatically captured with a camera and analyzed using SSOCR to produce a text file containing meter display values.
The `Chocolate Experiment' - A Demonstration of Radiation Absorption by Different Colored Surfaces
NASA Astrophysics Data System (ADS)
Fung, Dennis
2015-12-01
In the typical "cookbook" experiment comparing the radiation absorption rates of different colored surfaces, students' hands are commonly used as a measurement instrument to demonstrate that dull black and silvery surfaces are good and poor absorbers of radiation, respectively. However, college students are often skeptical about using their bare hands in this experiment because they learned in early science lessons that skin is not a reliable detector of heat transfer. Moreover, when the experiment is conducted in a school laboratory, it is often difficult for students to perceive the slight differences in heat transfer on the dull black and silvery aluminum leaves attached to their hands. Rather than replacing students' bare hands with such sophisticated apparatus as a data logger and temperature probe, I suggest using a simple (and delicious!) low-cost instrument, i.e., chocolate, which simply melts when it receives radiation.
Experimental study of efficiency of solar panel by phase change material cooling
NASA Astrophysics Data System (ADS)
Wei, Nicholas Tan Jian; Nan, Wong Jian; Guiping, Cheng
2017-07-01
The dependence of efficiency of photovoltaic panels on their temperature during operation is a major concern for developers and users. In this paper, a phase change material (PCM) cooling system was designed for a 60W mono-crystalline solar panel. Tealights candle was selected as the cooling medium. The solar irradiance was recorded using Kipp & Zonen CMP3 pyranometer and Meteon data logger. Temperature distribution on the surface of solar panel, output voltage and output current of solar panel were measured. The average irradiance throughout data collection was found to be 705W/m2 and highest irradiance was 1100 W/m2. The average solar panel temperature was 43.6°C and a maximum temperature of 53°C was at the center of solar panel. Results showed that average power output and efficiency of the solar panel were 44.4W and 15%, respectively. It was found that the higher the solar irradiance, the lower the efficiency of solar panel and the higher the temperature and power output of solar panel. This is due to the fact that high irradiance results in high power input and high solar panel temperature. But high PV panel temperature reduces its power output. Therefore, the increase of power input outweighs that of power output, which leads to the decrease of efficiency of solar panel with the increase of solar irradiance. Compared with solar panel without cooling, the power output and efficiency of solar panel did not increase with PCM cooling. It indicates that Tealights candle as PCM cooling is not efficient in improving the efficiency of solar panel in this study.
Thermal effects of Ho: YAG laser lithotripsy: real-time evaluation in an in vitro model.
Hein, Simon; Petzold, Ralf; Schoenthaler, Martin; Wetterauer, Ulrich; Miernik, Arkadiusz
2018-04-24
To evaluate the thermal effect of Ho:YAG laser lithotripsy in a standardized in vitro model via real-time temperature measurement. Our model comprised a 20 ml test tube simulating the renal pelvis that was immersed in a 37 °C water bath. Two different laser fibers [FlexiFib (15-45 W), RigiFib 1000 (45-100 W), LISA laser products OHG, Katlenburg-Lindau, Germany] were placed in the test tube. An Ho:YAG 100 W laser was used in all experiments (LISA). Each experiment involved 120 s of continuous laser application, and was repeated five times. Different laser settings (high vs. low frequency, high vs. low energy, and long vs. short pulse duration), irrigation rates (0 up to 100 ml/min, realized by several pumps), and human calcium oxalate stone samples were analyzed. Temperature data were acquired by a real-time data logger with thermocouples (PICO Technology, Cambridgeshire, UK). Real-time measurements were assessed using MatLab ® . Laser application with no irrigation results in a rapid increase in temperature up to ∆28 K, rising to 68 °C at 100 W. Low irrigation rates yield significantly higher temperature outcomes. Higher irrigation rates result immediately in a lower temperature rise. High irrigation rates of 100 ml/min result in a temperature rise of 5 K at the highest laser power setting (100 W). Ho:YAG laser lithotripsy might be safe provided that there is sufficient irrigation. However, high power and low irrigation resulted in potentially tissue-damaging temperatures. Laser devices should, therefore, always be applied in conjunction with continuous, closely monitored irrigation whenever performing Ho:YAG laser lithotripsy.
Spatial Characteristics of Small Green Spaces' Mitigating Effects on Microscopic Urban Heat Islands
NASA Astrophysics Data System (ADS)
Park, J.; Lee, D. K.; Jeong, W.; Kim, J. H.; Huh, K. Y.
2015-12-01
The purpose of the study is to find small greens' disposition, types and sizes to reduce air temperature effectively in urban blocks. The research sites were six high developed blocks in Seoul, Korea. Air temperature was measured with mobile loggers in clear daytime during summer, from August to September, at screen level. Also the measurement repeated over three times a day during three days by walking and circulating around the experimental blocks and the control blocks at the same time. By analyzing spatial characteristics, the averaged air temperatures were classified with three spaces, sunny spaces, building-shaded spaces and small green spaces by using Kruskal-Wallis Test; and small green spaces in 6 blocks were classified into their outward forms, polygonal or linear and single or mixed. The polygonal and mixed types of small green spaces mitigated averaged air temperature of each block which they belonged with a simple linear regression model with adjusted R2 = 0.90**. As the area and volume of these types increased, the effect of air temperature reduction (ΔT; Air temperature difference between sunny space and green space in a block) also increased in a linear relationship. The experimental range of this research is 100m2 ~ 2,000m2 of area, and 1,000m3 ~ 10,000m3 of volume of small green space. As a result, more than 300m2 and 2,300m3 of polygonal green spaces with mixed vegetation is required to lower 1°C; 650m2 and 5,000m3 of them to lower 2°C; about 2,000m2 and about 10,000m3 of them to lower 4°C air temperature reduction in an urban block.
Core-temperature sensor ingestion timing and measurement variability.
Domitrovich, Joseph W; Cuddy, John S; Ruby, Brent C
2010-01-01
Telemetric core-temperature monitoring is becoming more widely used as a noninvasive means of monitoring core temperature during athletic events. To determine the effects of sensor ingestion timing on serial measures of core temperature during continuous exercise. Crossover study. Outdoor dirt track at an average ambient temperature of 4.4°C ± 4.1°C and relative humidity of 74.1% ± 11.0%. Seven healthy, active participants (3 men, 4 women; age = 27.0 ± 7.5 years, height = 172.9 ± 6.8 cm, body mass = 67.5 ± 6.1 kg, percentage body fat = 12.7% ± 6.9%, peak oxygen uptake [Vo(2peak)] = 54.4 ± 6.9 mL•kg⁻¹•min⁻¹) completed the study. Participants completed a 45-minute exercise trial at approximately 70% Vo(2peak). They consumed core-temperature sensors at 24 hours (P1) and 40 minutes (P2) before exercise. Core temperature was recorded continuously (1-minute intervals) using a wireless data logger worn by the participants. All data were analyzed using a 2-way repeated-measures analysis of variance (trial × time), Pearson product moment correlation, and Bland-Altman plot. Fifteen comparisons were made between P1 and P2. The main effect of time indicated an increase in core temperature compared with the initial temperature. However, we did not find a main effect for trial or a trial × time interaction, indicating no differences in core temperature between the sensors (P1 = 38.3°C ± 0.2°C, P2 = 38.3°C ± 0.4°C). We found no differences in the temperature recordings between the 2 sensors. These results suggest that assumed sensor location (upper or lower gastrointestinal tract) does not appreciably alter the transmission of reliable and repeatable measures of core temperature during continuous running in the cold.
NASA Astrophysics Data System (ADS)
Godin, E.; Fortier, D.
2011-12-01
Thermo-erosion gullies often develop in ice-wedge polygons terrace and contribute to the dynamic evolution of the periglacial landscape. When snowmelt surface run-off concentrated into streams and water tracks infiltrate frost cracks, advective heat flow and convective thermal transfer from water to the ice-wedge ice enable the rapid development of tunnels and gullies in the permafrost (Fortier et al. 2007). Fine scale monitoring of the physical interaction between flowing water and ice rich permafrost had already been studied in a context of thermal erosion of a large river banks in Russia (Costard et al. 2003). Ice wedge polygons thermo-erosion process leading to gullying remains to be physically modelled and quantified. The present paper focus on the fine scale monitoring of thermo-erosion physical parameters both in the field and in laboratory. The physical model in laboratory was elaborated using a fixed block of ice monitored by a linear voltage differential transducer (LVDT) and temperature sensors connected to a logger. A water container with controlled discharge and temperature provided the fluid which flowed over the ice through a hose. Water discharge (Q), water temperature (Tw), ice melting temperature (Ti) and ice ablation rate (Ar) were measured. In laboratory, water at 281 Kelvin (K) flowing on the ice (Ti 273 K) made the ice melt at a rate Ar of 0.002 m min-1, under a continuous discharge of ≈ 8 x 10-7 m3 s-1. In the field, a small channel was dug between a stream and an exposed ice-wedge in a pre-existing active gully, where in 2010 large quantities of near zero snowmelt run-off water contributed to several meters of ice wedge ablation and gully development. Screws were fastened into the ice and a ruler was used to measure the ablation rate every minute. The surface temperature of the ice wedge was monitored with thermocouples connected to a logger to obtain the condition of the ice boundary layer. Discharge and water temperature were measured in the excavated channel just before the water got in contact with the ice surface. The field experiment where flowing water at Tw = 277 K, Ti = 273 K with a water discharge of 0.01 m3 s-1 resulted in a measured Ar of 0.01 to 0.02 m min-1. Water discharge and temperature difference between water and the melting ice were fundamental to ice ablation rate. The recent climate warming in the Canadian High Arctic will likely strongly contribute to the interaction and importance of the thermo-erosion and gullying processes in the High Arctic. Combined factors such as earlier or faster snowmelt, precipitation changes during the summer and positive feedback effects will probably increase the hydrological input to gullies and therefore enhance their development by thermo-erosion. Costard F. et al. 2003. Fluvial thermal erosion investigations along a rapidly eroding river bank: Application to the Lena River (central Siberia). Earth Surface Processes and Landforms 28: 1349-1359. Fortier D. et al. 2007. Observation of rapid drainage system development by thermal erosion of ice wedges on Bylot island, Canadian Arctic Archipelago. Permafrost and Periglacial Processes 18: 229-243.
NASA Astrophysics Data System (ADS)
Held, A. A.; Steduto, P.; Orgaz, F.; Matista, A.; Hsiao, T. C.
1990-12-01
This paper describes a Bowen ratio/energy balance (BREB) system which, in conjunction with an infra-red gas analyzer (IRGA), is referred to as BREB+ and is used to estimate evapotranspiration ( ET) and net CO2 flux ( NCF) over crop canopies. The system is composed of a net radiometer, soil heat flux plates, two psychrometers based on platinum resistance thermometers (PRT), bridge circuits to measure resistances, an IRGA, air pumps and switching valves, and a data logger. The psychrometers are triple shielded and aspirated, and with aspiration also between the two inner shields. High resistance (1 000 ohm) PRT's are used for dry and wet bulbs to minimize errors due to wiring and connector resistances. A high (55 K ohm) fixed resistance serves as one arm of the resistance bridge to ensure linearity in output signals. To minimize gaps in data, to allow measurements at short (e.g., 5 min) intervals, and to simplify operation, the psychrometers were fixed at their upper and lower position over the crop and not alternated. Instead, the PRT's, connected to the bridge circuit and the data logger, were carefully calibrated together. Field tests using a common air source showed appartent effects of the local environment around each psychrometer on the temperatures measured. ET rates estimated with the BREB system were compared to those measured with large lysimeters. Daily totals agreed within 5%. There was a tendency, however, for the lysimeter measurements to lag behind the BREB measurements. Daily patterns of NCF estimated with the BREB+ system are consistent with expectations from theories and data in the literature. Side-by-side comparisons with a stirred Mylar canopy chamber showed similar NCF patterns. On the other hand, discrepancies between the results of the two methods were quite marked in the morning or afternoon on certain dates. Part of the discrepancies may be attributed to inaccuracies in the psychrometric temperature measurements. Other possible causes include the highly artificial air turbulence in the canopy chamber and possible associated stomatal response. More work is necessary to identify conclusively the causes. In spite of these uncertainties, the BREB+ technique appears well suited for the automated and simultaneous tracking of photosynthetic performance and water economy of crops in their virtually undisturbed natural environment.
Exploring Quadratic Functions with Logger "Pro"
ERIC Educational Resources Information Center
Pope, Derek
2018-01-01
The author shares the lesson that he used to introduce the quadratic unit to students in an extended second-year algebra class, demonstrate why it was appropriate for his struggling learners, and discuss possible future modifications to this lesson.
Fabrication of the Appalachian Thinner
Cleveland J. Biller
1982-01-01
The Appalachian Thinner, a prototype cable yarder, has proven capable of harvesting timber on steep slopes. Details of the fabrication of the prototype yarder are presented. An Appalachian Thinner can be built economically in a typical logger's repair shop.
Iowa Saw-Log Production and Sawmill Industry, 1969
James E. Blyth
1972-01-01
Iowa loggers harvested nearly 47 million board feet of saw logs in 1969. Leading species were soft maple, elm, red oak, and cottonwood. Three-fifths of the wood residue generated at 63 Iowa sawmills was not used.
A portable smoking pattern recorder.
Creighton, D E; Noble, M J; Whewell, R T
1979-01-01
An instrument has been developed which can be used to record the smoking patterns of human smokers in almost any location. The smoker is required to smoke the cigarette through an orifice plate cigarette holder connected to the recorder. The smoking pattern data are recorded onto a standard audio cassette as pressure and flow signals together with timing impulses and speech. The instrument is battery powered and can be built into a small brief case. The four channels of data are decoded on a separate instrument, which uses the timing signals to synchronise a data logger, thus making the whole system independent of tape speed errors. The speech channel is used to identify the smoker, cigarette, location, etc. Comparisons have been made of the performance of the portable recorder and a laboratory smoking analyser and data logger. It was found that data decoded from the portable recorder are generally within 1% of the values recorded directly on the laboratory instrument.
NASA Astrophysics Data System (ADS)
Timi, Purnota Hannan; Shermin, Saima; Rahman, Asifur
2017-06-01
Flight data recorder is one of the most important sources of flight data in event of aviation disaster which records a wide range of flight parameters including altitude, airspeed, heading etc. and also helps monitoring and analyzing aircraft performance. Cockpit voice recorder records radio microphone transmissions and sounds in the cockpit. These devices help to find out and understand the root causes of aircraft crashes and help building better aircraft systems and technical solutions to prevent similar type of crashes in future, which lead to improvement in safety of aircrafts and passengers. There are other devices also which enhance the aircraft safety and assists in emergency or catastrophic situations. This paper discusses the concept of Flight Data Recorder (FDR), Cockpit Voice Recorder (CVR), Underwater Locator Beacon (ULB), Data logger and flarm-collision avoidance system for aircraft and their applications in aviation.
Data-acquisition system for environmental monitoring aboard a twin-engined aircraft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tichler, J.; Bernstein, H.; Brown, R.M.
A number of experimental platforms have been used in support of the Multistate Atmospheric Power Production Study (MAP3S) and the Coastal Meteorology programs at Brookhaven National Laboratory. These platforms include a twin-engine Britten Norman Islander aircraft, a motorized van, a variety of boats and temporary enclosures set up in the field. Each platform carried a data logger consisting of a multiplexer, an analog to digital (A/D) converter and a four track endless loop magnetic tape for data storage. In recent years it has become increasingly evident that the data loggers in use were no longer adequate. Since the aircraft providedmore » the most constraints on the data acquisition system as well as being the most important research platform, a data system was designed for that platform with the secondary goal that the system would serve as a prototype for systems to be used on other platforms.« less
Extreme Events in Urban Streams Leading to Extreme Temperatures in Birmingham, UK
NASA Astrophysics Data System (ADS)
Rangecroft, S.; Croghan, D.; Van Loon, A.; Sadler, J. P.; Hannah, D. M.
2016-12-01
Extreme flows and high water temperature events act as critical stressors on the ecological health of rivers. Urban headwater streams are considered particularly vulnerable to the effects of these extreme events. Despite this, such catchments remain poorly characterised and the effect of differences in land use is rarely quantified, especially in relation to water temperature. Thus a key research gap has emerged in understanding the patterns of water temperature during extreme events within contrasting urban, headwater catchments. We studied the headwaters of two bordering urban catchments of contrasting land use within Birmingham, UK. To characterise response to extreme events, precipitation and flow were analysed for the period of 1970-2016. To analyse the effects of extreme events on water temperature, 10 temperature loggers recording at 15 minute intervals were placed within each catchment covering a range of land use for the period May 2016 - present. During peak over threshold flood events higher average peaks were observed in the less urbanised catchment; however highest maximum flow peaks took place in the more densely urbanised catchment. Very similar average drought durations were observed between the two catchments with average flow drought durations of 27 days in the most urbanised catchment, and 29 in the less urbanised catchment. Flashier water temperature regimes were observed within the more urbanised catchment and increases of up to 5 degrees were apparent within 30 minutes during certain storms at the most upstream sites. Only in the most extreme events did the more densely urban stream appear more susceptible to both extreme high flows and extreme water temperature events, possibly resultant from overland flow emerging as the dominant flow pathway during intense precipitation events. Water temperature surges tended to be highly spatially variable indicating the importance of local land use. During smaller events, water temperature was less changeable and spatially variable, suggesting that overland flow may not the dominant flow pathway in such events. During drought events, the effect of catchment land use on water temperature was less apparent.
NASA Astrophysics Data System (ADS)
Jaapar, Mohd Fahimee; Jajuli, Rosliza; Mispan, Muhamad Radzali; Ghani, Idris Abd
2018-04-01
A study to investigate the foraging behavior of Heterotrigona itama (Cockerell, 1918) was conducted on three colonies between January 2016 and June 2016. A digital single-lens reflex (DSLR) with macro lens attached, and action camera (SJCAM) was used to record foraging behavior of H. itama in its colonies for 5 min per hour between 0800 to 1700 h for a day per 6 months. In addition, three data loggers (Watchdog B100 2K) has been installed adjacent to the observation nest for collect temperature and humidity in the study areas. Result showed that the numbers of return foragers was significantly different from January to June also with outgoing forager. The returning forager between hours showed significant different from 8 am to 5 pm also for outgoing forager. The ideal temperature related to foraging behavior for H. itama was 29°C to 32 °C Our finding also, helps to guide researcher to expand the knowledge in foraging behavior by stingless bee as well as encouraging more small farmers to start rearing at least for their own consumption. In addition, these findings also guide the farmers to manage their chemical toxic inside the meliponiculture.
Drone and Worker Brood Microclimates Are Regulated Differentially in Honey Bees, Apis mellifera.
Li, Zhiyong; Huang, Zachary Y; Sharma, Dhruv B; Xue, Yunbo; Wang, Zhi; Ren, Bingzhong
2016-01-01
Honey bee (Apis mellifera) drones and workers show differences in morphology, physiology, and behavior. Because the functions of drones are more related to colony reproduction, and those of workers relate to both survival and reproduction, we hypothesize that the microclimate for worker brood is more precisely regulated than that of drone brood. We assessed temperature and relative humidity (RH) inside honey bee colonies for both drone and worker brood throughout the three-stage development period, using digital HOBO® Data Loggers. The major findings of this study are that 1) both drone and worker castes show the highest temperature for eggs, followed by larvae and then pupae; 2) temperature in drones are maintained at higher precision (smaller variance) in drone eggs and larvae, but at a lower precision in pupae than the corresponding stages of workers; 3) RH regulation showed higher variance in drone than workers across all brood stages; and 4) RH regulation seems largely due to regulation by workers, as the contribution from empty honey combs are much smaller compared to that from adult workers. We conclude that honey bee colonies maintain both temperature and humidity actively; that the microclimate for sealed drone brood is less precisely regulated than worker brood; and that combs with honey contribute very little to the increase of RH in honey bee colonies. These findings increase our understanding of microclimate regulation in honey bees and may have implications for beekeeping practices.
Drone and Worker Brood Microclimates Are Regulated Differentially in Honey Bees, Apis mellifera
Li, Zhiyong; Huang, Zachary Y.; Sharma, Dhruv B.; Xue, Yunbo; Wang, Zhi; Ren, Bingzhong
2016-01-01
Background Honey bee (Apis mellifera) drones and workers show differences in morphology, physiology, and behavior. Because the functions of drones are more related to colony reproduction, and those of workers relate to both survival and reproduction, we hypothesize that the microclimate for worker brood is more precisely regulated than that of drone brood. Methodology/Principal Findings We assessed temperature and relative humidity (RH) inside honey bee colonies for both drone and worker brood throughout the three-stage development period, using digital HOBO® Data Loggers. The major findings of this study are that 1) both drone and worker castes show the highest temperature for eggs, followed by larvae and then pupae; 2) temperature in drones are maintained at higher precision (smaller variance) in drone eggs and larvae, but at a lower precision in pupae than the corresponding stages of workers; 3) RH regulation showed higher variance in drone than workers across all brood stages; and 4) RH regulation seems largely due to regulation by workers, as the contribution from empty honey combs are much smaller compared to that from adult workers. Conclusions/Significance We conclude that honey bee colonies maintain both temperature and humidity actively; that the microclimate for sealed drone brood is less precisely regulated than worker brood; and that combs with honey contribute very little to the increase of RH in honey bee colonies. These findings increase our understanding of microclimate regulation in honey bees and may have implications for beekeeping practices. PMID:26882104
Cooling performance and evaluation of automotive refrigeration system for a passenger car
NASA Astrophysics Data System (ADS)
Prajitno, Deendarlianto, Majid, Akmal Irfan; Mardani, Mahardeka Dhias; Wicaksono, Wendi; Kamal, Samsul; Purwanto, Teguh Pudji; Fauzun
2016-06-01
A new design of automotive refrigeration system for a passenger car was proposed. To ensure less energy consumption and optimal thermal comfort, the performance of the system were evaluated. This current research was aimed to evaluate the refrigeration characteristics of the system for several types of cooling load. In this present study, a four-passenger wagon car with 1500 cc gasoline engine that equipped by a belt driven compressor (BDC) was used as the tested vehicle. To represent the tropical condition, a set of lamps and wind sources are installed around the vehicle. The blower capacity inside a car is varied from 0.015 m/s to 0.027 m/s and the compressor speed is varied at variable 820, 1400, and 2100 rpm at a set temperature of 22°C. A set of thermocouples that combined by data logger were used to measure the temperature distribution. The system uses R-134a as the refrigerant. In order to determine the cooling capacity of the vehicle, two conditions were presented: without passengers and full load conditions. As the results, cooling capacity from any possible heating sources and transient characteristics of temperature in both systems for the cabin, engine, compressor, and condenser are presented in this work. As the load increases, the outlet temperature of evaporator also increases due to the increase of condensed air. This phenomenon also causes the increase of compressor work and compression ratio which associated to the addition of specific volume in compressor inlet.
NASA Astrophysics Data System (ADS)
Lydersen, Christian; Anders Nøst, Ole; Kovacs, Kit M.; Fedak, Mike A.
2004-05-01
Free-living ringed seals ( N=11) equipped with satellite-relayed data loggers (SRDLs) with incorporated oceanographic-quality temperature sensors were used to collect data from a large sector of the northern Barents Sea during the autumn and early winter. A total of 2346 temperature profiles were collected over a 4-month period from Norwegian and Russian arctic waters in areas that were at times 90-100% ice-covered. Temperature distributions at different depths from northeastern parts of Svalbard, Norway show warm North Atlantic water (NAW) flowing along the continental slope and gradually cooling at all depths as it flows eastwards. The data suggest that most of the cooling takes place west of 30°E. Vertical temperature profiles from the area between Svalbard and Franz Josef Land, Russia show how the surface water cools during freeze-up and demonstrate a warm water flow, which is probably NAW, coming in from the north through a deep trench west of Franz Josef Land. Global oceanographic and climate models require improved oceanographic databases from crucial areas where important hydrological phenomena occur. Such areas in arctic waters are often inaccessible during winter and logistically difficult to reach even in summer. The present study demonstrates how large amounts of oceanographic information can be collected and retrieved in a cost-efficient manner using ice-associated marine mammals as carrier of oceanographic sampling equipment. In addition to the oceanographic value of the data collected by marine mammals in this manner, a vast amount of information regarding the habitat of these animals is concomitantly sampled.
NASA Astrophysics Data System (ADS)
Gomez, A. M.; McDonald, K. C.; Shein, K. A.; Devries, S. L.; Armstrong, R.; Carlo, M.
2017-12-01
The third global coral bleaching event, which began in mid-2014, is a major environmental stressor that has been causing significant documented damage to coral reefs in all tropical ocean basins. This worldwide phenomenon is the longest and largest coral bleaching event on record and now finally appears to be ending. During this event, some coral colonies proved to be more resilient to increased ocean temperatures while others bleached severely. This research investigates the spatial and temporal variability of bleaching stress on coral reefs in La Parguera, Puerto Rico, and Southeastern Florida to help further understand the role of temperature and light in coral bleaching. We examine the microclimate within two coral reef systems, using in situ collections of temperature and light data from data loggers deployed throughout Cayo Enrique and Cayo Mario in La Parguera, and Lauderdale-By-The-Sea in FLorida. The in situ measurements are compared to NOAA Coral Reef Watch's 5-km sea surface temperature data as well as to the associated Light Stress Damage Product. Research outcomes include statistical analyses of in situ measurements with satellite datasets supporting enhanced interpretation of satellite-based SST and light products, and ecological niche modeling to assess where corals could potentially survive under future climate conditions. Additional understanding of the microclimate encompassing coral reefs and improved satellite SST and light data will ultimately help coral reef ecosystem managers and policy makers in prioritizing resources toward the monitoring and protection of coral reef ecosystems.
Towards a Community Environmental Observation Network
NASA Astrophysics Data System (ADS)
Mertl, Stefan; Lettenbichler, Anton
2014-05-01
The Community Environmental Observation Network (CEON) is dedicated to the development of a free sensor network to collect and distribute environmental data (e.g. ground shaking, climate parameters). The data collection will be done with contributions from citizens, research institutions and public authorities like communities or schools. This will lead to a large freely available data base which can be used for public information, research, the arts,..... To start a free sensor network, the most important step is to provide easy access to free data collection and -distribution tools. The initial aims of the project CEON are dedicated to the development of these tools. A high quality data logger based on open hardware and free software is developed and a software suite of already existing free software for near-real time data communication and data distribution over the Internet will be assembled. Foremost, the development focuses on the collection of data related to the deformation of the earth (such as ground shaking, surface displacement of mass movements and glaciers) and the collection of climate data. The extent to other measurements will be considered in the design. The data logger is built using open hardware prototyping platforms like BeagleBone Black and Arduino. Main features of the data logger are: a 24Bit analog-to-digital converter; a GPS module for time reference and positioning; wireless mesh networking using Optimized Link State Routing; near real-time data transmission and communication; and near real-time differential GNSS positioning using the RTKLIB software. The project CEON is supported by the Internet Foundation Austria (IPA) within the NetIdee 2013 call.
Wildlife contact analysis: Emerging methods, questions, and challenges
Cross, Paul C.; Creech, Tyler G.; Ebinger, Michael R.; Heisey, Dennis M.; Irvine, Kathryn M.; Creel, Scott
2012-01-01
Recent technological advances, such as proximity loggers, allow researchers to collect complete interaction histories, day and night, among sampled individuals over several months to years. Social network analyses are an obvious approach to analyzing interaction data because of their flexibility for fitting many different social structures as well as the ability to assess both direct contacts and indirect associations via intermediaries. For many network properties, however, it is not clear whether estimates based upon a sample of the network are reflective of the entire network. In wildlife applications, networks may be poorly sampled and boundary effects will be common. We present an alternative approach that utilizes a hierarchical modeling framework to assess the individual, dyadic, and environmental factors contributing to variation in the interaction rates and allows us to estimate the underlying process variation in each. In a disease control context, this approach will allow managers to focus efforts on those types of individuals and environments that contribute the most toward super-spreading events. We account for the sampling distribution of proximity loggers and the non-independence of contacts among groups by only using contact data within a group during days when the group membership of proximity loggers was known. This allows us to separate the two mechanisms responsible for a pair not contacting one another: they were not in the same group or they were in the same group but did not come within the specified contact distance. We illustrate our approach with an example dataset of female elk from northwestern Wyoming and conclude with a number of important future research directions.
O'Neill, C J; Bishop-Hurley, G J; Williams, P J; Reid, D J; Swain, D L
2014-12-10
Reproductive efficiency is an important determinant of profitable cattle breeding systems and the success of assisted reproductive techniques (ART) in wildlife conservation programs. Methods of estrous detection used in intensive beef and dairy cattle systems lack accuracy and remain the single biggest issue for improvement of reproductive rates and such methods are not practical for either large-scale extensive beef cattle enterprises or free-living mammalian species. Recent developments in UHF (ultra high frequency) proximity logger telemetry devices have been used to provide a continuous pair-wise measure of associations between individual animals for both livestock and wildlife. The objective of this study was to explore the potential of using UHF telemetry to identify the reproductive cycle phenotype in terms of intensity and duration of estrus. The study was conducted using Belmont Red (interbred Africander Brahman Hereford-Shorthorn) cattle grazing irrigated pasture on Belmont Research Station, northeastern Australia. The cow-bull associations from three groups of cows each with one bull were recorded over a 7-week breeding season and the stage of estrus was identified using ultrasonography. Telemetry data from bull and cows, collected over 4 8-day logger deployments, were log transformed and analyzed by ANOVA. Both the number and duration of bull-cow affiliations were significantly (P<0.001) greater in estrous cows compared to anestrus cows. These results support the development of the UHF technology as a hands-off and noninvasive means of gathering socio-sexual information on both wildlife and livestock for reproductive management. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., including farmers, ranchers, loggers, agricultural harvesters and fishermen, that engage in the production or harvesting of an agricultural product. Producers may or may not own the land or other production..., value of production, increased diversification of industry, higher labor force participation rates...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., including farmers, ranchers, loggers, agricultural harvesters and fishermen, that engage in the production or harvesting of an agricultural product. Producers may or may not own the land or other production..., value of production, increased diversification of industry, higher labor force participation rates...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., including farmers, ranchers, loggers, agricultural harvesters and fishermen, that engage in the production or harvesting of an agricultural product. Producers may or may not own the land or other production..., value of production, increased diversification of industry, higher labor force participation rates...
NASA Technical Reports Server (NTRS)
1994-01-01
This video presents two examples of NASA Technology Transfer. The first is a Downhole Video Logger, which uses remote sensing technology to help in mining. The second example is the use of satellite image processing technology to enhance ultrasound images taken during pregnancy.
USDA-ARS?s Scientific Manuscript database
This application was designed for farmers, agriculture researchers, and gardeners. The application includes a calculator, a data logger, and a GPS mapping function. It was designed for vegetable farming but can be used for open field applications. The calculator solves for the amount of pesticide,...
Hardwood thinning opportunities in the Lake States.
John A. Sturos
1986-01-01
The symposium presents and discusses new information on the hardwood resource, silviculture, harvesting, economics, and product potential from hardwood thinnings in the Lake States. Included are forest management perspectives from the logger, private industry, and state and federal forest managers.
Prediction of parturition in Holstein dairy cattle using electronic data loggers.
Titler, M; Maquivar, M G; Bas, S; Rajala-Schultz, P J; Gordon, E; McCullough, K; Federico, P; Schuenemann, G M
2015-08-01
The objective of the present study was to assess the effect of parturition on behavioral activity [steps, standing time, lying time, lying bouts (LB), and duration of LB] 4 d before calving using electronic data loggers. Animals (n=132) from 3 herds were housed in similar freestall barns using a prepartum pen 21 d before the expected calving date and were moved into a contiguous individual maternity pen for parturition. Electronic data loggers were placed on a hind leg of prepartum heifers (heifers, n=33) and cows (cows, n=99) at 7±3 d before the expected calving date and removed at 14±3 d in milk. Calving ease (scale 1-4), parity, calving date and time, and stillbirth (born dead or died within 24h) were recorded. The number of steps (no./d), standing time (min/d), lying time (min/d), number of LB (no./d), and duration of LB (min/b) were recorded. Data were analyzed using MIXED procedures of SAS, adjusting for the herd effect. Only cows experiencing unassisted births (calving ease=1) were included in the study. An activity index was developed to predict calving time. Heifers and cows with unassisted births had significantly higher number of steps and longer standing time, decreased lying time, and more LB of shorter duration 24h before calving compared with d -4, -3, and -2. Additionally, the number of LB increased as both heifers and cows approached labor starting on d -2 and peaked at the day of calving. The time since the activity index increased over 50% to parturition did not differ between heifers and cows, and the activity index revealed the shift in activity on average 6h 14min (range from 2h to 14h 15min) before calf birth. This study provided evidence that heifers and cows approaching parturition showed a similar, but distinct, behavioral pattern that can be observed on average 6h before calf birth. The potential benefits of electronic data loggers as predictors of parturition along with proactive management practices should improve the overall survival and welfare of both the dam and calf. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Development of a Wireless Network of Temperature Sensors for Yellowstone National Park (USA)
NASA Astrophysics Data System (ADS)
Munday, D. A.; Hutter, T.; Minolli, M.; Obraczka, K.; Manduchi, R.; Petersen, S.; Lowenstern, J. B.; Heasler, H.
2007-12-01
Temperature sensors deployed at Yellowstone clearly document that thermal features can vary in temperature on a variety of timescales and show regional correlations unrelated to meteorological variables such as air temperature. Yellowstone National Park (YNP) staff currently measures temperatures at over 40 thermal features and streams within the park, utilizing USGS stream gaging stations and portable data loggers deployed in geyser basins. The latter measure temperature every 1 to 15 minutes, and the data are physically downloaded after about 30 days. Installation of a wireless sensor network would: 1) save considerable time and effort in data retrieval, 2) minimize lost data due to equipment failure, and 3) provide a means to monitor thermal perturbations in near-real time. To meet this need, we developed a wireless sensor network capable of in-situ monitoring of air and water temperature. Temperature sensors are dispersed as nodes that communicate among themselves and through relays to a single base-station linked to the Internet. The small, weatherproof sensors operate unattended for over six months at temperatures as low as -40°C. Each uses an ultra-low-power Texas Instruments' MSP430 microcontroller and an SD card as mass storage. They are powered by 15Ah, 3.6 v, inert Li-ion batteries and transmit data via 900MHz radio modules with a 1-km range. The initial prototype consists of 4 nodes, and is designed to scale with additional nodes for finer spatial resolution and broader coverage. Temperature measurements are asynchronous from node to node, with intervals as frequent as 30 seconds. Data are stored internally to withstand temporary communication failures; underlying intelligent software is capable of re-routing data through alternative nodes to the base station and a MySQL data archiving system. We also developed a Google-Maps-based, front-end that displays the data, recent trends and sensor locations. The system was tested in the Santa Cruz Mountains and will be used at Yellowstone National Park during Fall 2007.
Mitchell, Duncan; Fuller, Andrea; Maloney, Shane K
2009-05-01
Other than the hominin lineage, baboons are the diurnally active primates that have colonized the arid plains of Africa most successfully. While the hominin lineage adopted bipedalism before colonizing the open, dry plains, baboons retained a quadrupedal mode of locomotion. Because bipedalism has been considered to reduce the thermoregulatory stress of inhabiting open dry plains, we investigated how baboons cope with thermal loads and water restriction. Using implanted data loggers, we measured abdominal temperature every 5 min in six unrestrained baboons while they were exposed to simulated desert conditions (15 degrees C at night rising to 35 degrees C during the day, with and without extra radiant heating), or an ambient temperature of 22 degrees C. At 22 degrees C, core temperature averaged 37.9 degrees C and cycled nychthemerally by 1.7 degrees C. Mean, minimum, and maximum daily core temperatures in euhydrated baboons in the simulated desert environments did not differ from the temperatures displayed in the 22 degrees C environment, even when radiant heating was applied. At 22 degrees C, restricting water intake did not affect core temperature. During the desert simulations, maximum core temperature increased significantly on each day of water deprivation, with the highest temperatures (>40 degrees C) on the third day in the simulation that included radiant heat. When drinking water heated to 38 degrees C was returned, core temperature decreased rapidly to a level lower than normal for that time of day. We conclude that baboons with access to water can maintain homeothermy in the face of high air temperatures and radiant heat loads, but that a lack of access to drinking water poses a major threat to baboon homeothermy. We speculate that any competitive thermoregulatory advantage of bipedalism in early hominins was related to coping with water shortage in hot environments, and that their freed hands might have enabled them to transport enough water to avoid dangerous hyperthermia.
Modeling shade tree use by beef cattle as a function of black globe temperature and time of day
NASA Astrophysics Data System (ADS)
Foust, Amanda M.; Headlee, William L.
2017-12-01
Increasing temperatures associated with global climate change threaten to disrupt agricultural systems such as beef production, yet relatively little is known about the use of natural tree shade to mitigate the negative effects of heat stress on beef cattle. In this study, we evaluated how temperature and time of day influenced the utilization of tree shade in relation to coloration, orientation, and behavior of beef cattle in a pasture system. Temperatures in shade and direct sunlight were measured using black globe temperature (BGT) data loggers. Time-lapse images from game cameras were used to obtain counts of shade usage, coloration, orientation, and behavior of cattle throughout the daytime hours. In general, we found that shade utilization and most of the predominating orientations and behaviors differed significantly ( P < 0.05) by both time of day (Hour) and BGT in direct sunlight (BGTsun), while interactions between these two effects (Hour × BGTsun) were often nonsignificant. The mean percentage of the herd using shade was highest in mid-morning (87-96%) and early afternoon (97%), but also increased with BGTsun regardless of the time of day; these trends were similar for both dark- and light-colored cattle. Lying down was the dominant behavior exhibited in the shade, while foraging was the most prevalent behavior in the sun. When herd shade usage was lowest in mid- to late-afternoon (<1%) we also observed an increase in the use of heat-mitigating orientations in the sun (37-47%). We discuss some practical implications of these results, including the potential use of temperature thresholds to interpret cattle behaviors and shade usage.
Modeling shade tree use by beef cattle as a function of black globe temperature and time of day.
Foust, Amanda M; Headlee, William L
2017-12-01
Increasing temperatures associated with global climate change threaten to disrupt agricultural systems such as beef production, yet relatively little is known about the use of natural tree shade to mitigate the negative effects of heat stress on beef cattle. In this study, we evaluated how temperature and time of day influenced the utilization of tree shade in relation to coloration, orientation, and behavior of beef cattle in a pasture system. Temperatures in shade and direct sunlight were measured using black globe temperature (BGT) data loggers. Time-lapse images from game cameras were used to obtain counts of shade usage, coloration, orientation, and behavior of cattle throughout the daytime hours. In general, we found that shade utilization and most of the predominating orientations and behaviors differed significantly (P < 0.05) by both time of day (Hour) and BGT in direct sunlight (BGT sun ), while interactions between these two effects (Hour × BGT sun ) were often nonsignificant. The mean percentage of the herd using shade was highest in mid-morning (87-96%) and early afternoon (97%), but also increased with BGT sun regardless of the time of day; these trends were similar for both dark- and light-colored cattle. Lying down was the dominant behavior exhibited in the shade, while foraging was the most prevalent behavior in the sun. When herd shade usage was lowest in mid- to late-afternoon (<1%) we also observed an increase in the use of heat-mitigating orientations in the sun (37-47%). We discuss some practical implications of these results, including the potential use of temperature thresholds to interpret cattle behaviors and shade usage.
Ramirez-Arcos, Sandra; Mastronardi, Cherie; Perkins, Heather; Kou, Yuntong; Turner, Tracey; Mastronardi, Emily; Hansen, Adele; Yi, Qi-Long; McLaughlin, Natasha; Kahwash, Eiad; Lin, Yulia; Acker, Jason
2013-04-01
A 30-minute rule was established to limit red blood cell (RBC) exposure to uncontrolled temperatures during storage and transportation. Also, RBC units issued for transfusion should not remain at room temperature (RT) for more than 4 hours (4-hour rule). This study was aimed at determining if single or multiple RT exposures affect RBC quality and/or promote bacterial growth. Growth and RT exposure experiments were performed in RBCs inoculated with Serratia liquefaciens and Serratia marcescens. RBCs were exposed once to RT for 5 hours (S. liquefaciens) or five times to RT for 30 minutes (S. marcescens) with periodic sampling for bacterial counts. Noncontaminated units were exposed to RT once (5 hr) or five times (30 min each) and sampled to measure in vitro quality variables. RBC core temperature was monitored using mock units with temperature loggers. Growth and RT exposure experiments were repeated three and at least six times, respectively. Statistical analysis was done using mixed-model analysis. RBC core temperature ranged from 7.3 to 11.6°C during 30-minute RT exposures and the time to reach 10°C varied from 22 to 55 minutes during 5-hour RT exposures. RBC quality was preserved after single or multiple RT exposures. Increased growth of S. liquefaciens was only observed after 2 hours of continuous RT exposure. S. marcescens concentration increased significantly in multiple-exposed units compared to the controls but did not reach clinically important levels. Single or multiple RT exposures did not affect RBC quality but slightly promoted bacterial growth in contaminated units. The clinical significance of these results remains unclear and needs further investigation. © 2012 American Association of Blood Banks.
Kuffner, Ilsa B.; Roberts, Kelsey E.; Flannery, Jennifer A.; Morrison, Jennifer M.; Richey, Julie
2017-01-01
Massive corals provide a useful archive of environmental variability, but careful testing of geochemical proxies in corals is necessary to validate the relationship between each proxy and environmental parameter throughout the full range of conditions experienced by the recording organisms. Here we use samples from a coral-growth study to test the hypothesis that Sr/Ca in the coral Siderastrea siderea accurately records sea-surface temperature (SST) in the subtropics (Florida, USA) along 350 km of reef tract. We test calcification rate, measured via buoyant weight, and linear extension (LE) rate, estimated with Alizarin Red-S staining, as predictors of variance in the Sr/Ca records of 39 individual S. siderea corals grown at four outer-reef locations next to in-situ temperature loggers during two, year-long periods. We found that corals with calcification rates < 1.7 mg cm−2 d−1 or < 1.7 mm yr−1 LE returned spuriously high Sr/Ca values, leading to a cold-bias in Sr/Ca-based SST estimates. The threshold-type response curves suggest that extension rate can be used as a quality-control indicator during sample and drill-path selection when using long cores for SST paleoreconstruction. For our corals that passed this quality control step, the Sr/Ca-SST proxy performed well in estimating mean annual temperature across three sites spanning 350 km of the Florida reef tract. However, there was some evidence that extreme temperature stress in 2010 (cold snap) and 2011 (SST above coral-bleaching threshold) may have caused the corals not to record the temperature extremes. Known stress events could be avoided during modern calibrations of paleoproxies.
Curtis, A K; Scharf, B; Eichen, P A; Spiers, D E
2017-01-01
Heat stress in feedlot cattle is known to reduce their performance. The challenge comes in determining reliable predictors of current and near-future changes in thermal status and performance. A 42-d study, using crossbred (Bos taurus) steers was conducted during summer months (July through August) to identify best environmental determinants of rumen temperature (T rumen ) and feed intake (FI) in feedlot cattle with access to shade. A further goal was to define the relationship between T rumen and FI. Shade coverage was approximately 50%, and all animals were provided standard feedlot diets and water ad libitum. Intraruminal telemetric boluses recorded T rumen several times each hour. Ear tags, telemetrically connected to a feed monitoring system, provided FI data using RFID technology. Data loggers recorded ambient conditions in sun and shade, along with black globe temperature. Regression analyses identified daylight black globe and air temperatures in shade, with one hour delays, as the best predictors of T rumen . Prediction of FI was much less reliable. Unexpectedly, T rumen was not superior to ambient variables in predicting FI. Maximum daily temperature humidity index, calculated using BG in sun with a 5-d lag, was the best significant predictor of FI. These results indicate for feedlot cattle that although air temperature alone in the shade may be the best predictor of T rumen in the heat, black globe temperature in the sun may be a better determinant of feed intake over time. Additional studies are needed to verify the delayed FI response which seems unusually long. Copyright © 2016 Elsevier Ltd. All rights reserved.
Streicher, S; Lutermann, H; Bennett, N C; Bertelsen, M F; Mohammed, O B; Manger, P R; Scantlebury, M; Ismael, K; Alagaili, A N
2017-01-01
Heterothermy, the ability to allow body temperature (Tb) to fluctuate, has been proposed as an adaptive mechanism that enables large ungulates to cope with the high environmental temperatures and lack of free water experienced in arid environments. By storing heat during the daytime and dissipating it during the night, arid-adapted ungulates may reduce evaporative water loss and conserve water. Adaptive heterothermy in large ungulates should be particularly pronounced in hot environments with severely limited access to free water. In the current study we investigated the effects of environmental temperature (ambient, Ta and soil, Ts) and water stress on the Tb of wild, free-ranging Arabian oryx (Oryx leucoryx) in two different sites in Saudi Arabia, Mahazat as-Sayd (MS) and Uruq Bani Ma'arid (UBM). Using implanted data loggers wet took continuous Tb readings every 10 minutes for an entire calendar year and determined the Tb amplitude as well as the heterothermy index (HI). Both differed significantly between sites but contrary to our expectations they were greater in MS despite its lower environmental temperatures and higher rainfall. This may be partially attributable to a higher activity in an unfamiliar environment for translocated animals in UBM. As expected Tb amplitude and HI were greatest during summer. Only minor sex differences were apparent that may be attributable to sex-specific investment into reproduction (e.g. male-male competition) during rut. Our results suggest that the degree of heterothermy is not only driven by extrinsic factors (e.g. environmental temperatures and water availability), but may also be affected by intrinsic factors (e.g. sex and/or behaviour).
Lutermann, H.; Bennett, N. C.; Bertelsen, M. F.; Mohammed, O. B.; Manger, P. R.; Scantlebury, M.; Ismael, K.; Alagaili, A. N.
2017-01-01
Heterothermy, the ability to allow body temperature (Tb) to fluctuate, has been proposed as an adaptive mechanism that enables large ungulates to cope with the high environmental temperatures and lack of free water experienced in arid environments. By storing heat during the daytime and dissipating it during the night, arid-adapted ungulates may reduce evaporative water loss and conserve water. Adaptive heterothermy in large ungulates should be particularly pronounced in hot environments with severely limited access to free water. In the current study we investigated the effects of environmental temperature (ambient, Ta and soil, Ts) and water stress on the Tb of wild, free-ranging Arabian oryx (Oryx leucoryx) in two different sites in Saudi Arabia, Mahazat as-Sayd (MS) and Uruq Bani Ma’arid (UBM). Using implanted data loggers wet took continuous Tb readings every 10 minutes for an entire calendar year and determined the Tb amplitude as well as the heterothermy index (HI). Both differed significantly between sites but contrary to our expectations they were greater in MS despite its lower environmental temperatures and higher rainfall. This may be partially attributable to a higher activity in an unfamiliar environment for translocated animals in UBM. As expected Tb amplitude and HI were greatest during summer. Only minor sex differences were apparent that may be attributable to sex-specific investment into reproduction (e.g. male-male competition) during rut. Our results suggest that the degree of heterothermy is not only driven by extrinsic factors (e.g. environmental temperatures and water availability), but may also be affected by intrinsic factors (e.g. sex and/or behaviour). PMID:28854247
Autonomous Ice Mass Balance Buoys for Seasonal Sea Ice
NASA Astrophysics Data System (ADS)
Whitlock, J. D.; Planck, C.; Perovich, D. K.; Parno, J. T.; Elder, B. C.; Richter-Menge, J.; Polashenski, C. M.
2017-12-01
The ice mass-balance represents the integration of all surface and ocean heat fluxes and attributing the impact of these forcing fluxes on the ice cover can be accomplished by increasing temporal and spatial measurements. Mass balance information can be used to understand the ongoing changes in the Arctic sea ice cover and to improve predictions of future ice conditions. Thinner seasonal ice in the Arctic necessitates the deployment of Autonomous Ice Mass Balance buoys (IMB's) capable of long-term, in situ data collection in both ice and open ocean. Seasonal IMB's (SIMB's) are free floating IMB's that allow data collection in thick ice, thin ice, during times of transition, and even open water. The newest generation of SIMB aims to increase the number of reliable IMB's in the Arctic by leveraging inexpensive commercial-grade instrumentation when combined with specially developed monitoring hardware. Monitoring tasks are handled by a custom, expandable data logger that provides low-cost flexibility for integrating a large range of instrumentation. The SIMB features ultrasonic sensors for direct measurement of both snow depth and ice thickness and a digital temperature chain (DTC) for temperature measurements every 2cm through both snow and ice. Air temperature and pressure, along with GPS data complete the Arctic picture. Additionally, the new SIMB is more compact to maximize deployment opportunities from multiple types of platforms.
Cold-induced mortality of invasive Burmese pythons in south Florida
Mazzotti, Frank J.; Cherkiss, Michael S.; Hart, Kristen M.; Snow, Ray W.; Rochford, Michael R.; Dorcas, Michael E.; Reed, Robert N.
2011-01-01
A recent record cold spell in southern Florida (2–11 January 2010) provided an opportunity to evaluate responses of an established population of Burmese pythons (Python molurus bivittatus) to a prolonged period of unusually cold weather. We observed behavior, characterized thermal biology, determined fate of radio-telemetered (n = 10) and non-telemetered (n = 104) Burmese pythons, and analyzed habitat and environmental conditions experienced by pythons during and after a historic cold spell. Telemetered pythons had been implanted with radio-transmitters and temperature-recording data loggers prior to the cold snap. Only one of 10 telemetered pythons survived the cold snap, whereas 59 of 99 (60%) non-telemetered pythons for which we determined fate survived. Body temperatures of eight dead telemetered pythons fluctuated regularly prior to 9 January 2010, then declined substantially during the cold period (9–11 January) and exhibited no further evidence of active thermoregulation indicating they were likely dead. Unusually cold temperatures in January 2010 were clearly associated with mortality of Burmese pythons in the Everglades. Some radio-telemetered pythons appeared to exhibit maladaptive behavior during the cold spell, including attempting to bask instead of retreating to sheltered refugia. We discuss implications of our findings for persistence and spread of introduced Burmese pythons in the United States and for maximizing their rate of removal.
NASA Astrophysics Data System (ADS)
Chow, Winston; Ho, Dawn
2016-04-01
In numerous cities, measurements of urban warmth in most urban heat island (UHI) studies are generally constrained towards surface or near-surface (<2 m above surface level) levels across horizontal variations in land use and land cover. However, there has been hitherto limited attention towards the measurement of vertical temperature profiles extending from the urban surface, urban canopy layer through to the urban boundary layer. Knowledge of these profiles, through (a.) how they vary over different local urban morphologies, and (b.) develop with respect to synoptic meteorological conditions, are important towards several aspects of UHI research; these include validating modelling urban canopy lapse rate profiles or estimating the growth of urban plumes. In this novel study, we utilised temperature sensor-loggers attached onto remote controlled aerial quadcopter platforms to measure urban temperature profiles up to 100 m above ground level in Singapore, which is a rapidly urbanizing major tropical metropolis. Three different land use/land cover categories were sampled; a high-rise residential estate, a university campus, and an urban park/green-space. Sorties were flown repeatedly at four different times - sunrise, noon, sunset and midnight. Initial results indicate significant variations in intra-site stability and inversion development between the urban canopy and boundary layers. These profiles are also temporally dynamic, depending on the time of day and larger-scale weather conditions.
Characteristics of sediment discharge in the subarctic Yukon River, Alaska
Chikita, K.A.; Kemnitz, R.; Kumai, R.
2002-01-01
The characteristics of sediment discharge in the Yukon River, Alaska were investigated by monitoring water discharge, water turbidity and water temperature. The river-transported sediment, 90 wt.% or more, consists of silt and clay (grain size ??? 62.5 ??m), which probably originated in the glacier-covered mountains mostly in the Alaska Range. For early June to late August 1999, we continuously measured water turbidity and temperature near the estuary and in the middle of Yukon River by using self-recording turbidimeters and temperature data loggers. The water turbidity (ppm) was converted to suspended sediment concentration (SSC; mg/l) of river water, using a relation between simultaneous turbidity and SSC at each of the two sites, and then, the suspended sediment discharge, approximately equal to water discharge times SSC, was numerically obtained every 1 or 2 h. It should be noted that the sediment discharge in the Yukon River is controlled by SSC rather than water discharge. As a result, a peak sediment discharge occurred in mid or late August by local sediment runoffs due to glacier-melt (or glacier-melt plus rainfall), while a peak water discharge was produced by snowmelt in late June or early July. Application of the "extended Shields diagram" indicates that almost all the river-transported sediments are under complete suspension. ?? 2002 Elsevier Science B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Grillo, Barbara; Braitenberg, Carla; Nagy, Ildikó; Devoti, Roberto; Zuliani, David; Fabris, Paolo
2018-04-01
Ten years' geodetic observations (2006-2016) in a natural cave of the Cansiglio Plateau (Bus de la Genziana), a limestone karstic area in northeastern Italy, are discussed. The area is of medium-high seismic risk: a strong earthquake in 1936 below the plateau (M m = 6.2) and the 1976 disastrous Friuli earthquake (M m = 6.5) are recent events. At the foothills of the karstic massif, three springs emerge, with average flow from 5 to 10 m3/s, and which are the sources of a river. The tiltmeter station is set in a natural cavity that is part of a karstic system. From March 2013, a multiparametric logger (temperature, stage, electrical conductivity) was installed in the siphon at the bottom of the cave to discover the underground hydrodynamics. The tilt records include signals induced by hydrologic and tectonic effects. The tiltmeter signals have a clear correlation to the rainfall, the discharge series of the river and the data recorded by multiparametric loggers. Additionally, the data of a permanent GPS station located on the southern slopes of the Cansiglio Massif (CANV) show also a clear correspondence with the river level. The fast water infiltration into the epikarst, closely related to daily rainfall, is distinguished in the tilt records from the characteristic time evolution of the karstic springs, which have an impulsive level increase with successive exponential decay. It demonstrates the usefulness of geodetic measurements to reveal the hydrological response of the karst. One outcome of the work is that the tiltmeters can be used as proxies for the presence of flow channels and the pressure that builds up due to the water flow. With 10 years of data, a new multidisciplinary frontier was opened between the geodetic studies and the karstic hydrogeology to obtain a more complete geologic description of the karst plateau.
Sterling, Jeremy T; Springer, Alan M.; Iverson, Sara J.; Johnson, Shawn P.; Pelland, Noel A.; Johnson, Devin S.; Lea, Mary-Anne; Bond, Nicholas A.
2014-01-01
Adult male and female northern fur seals (Callorhinus ursinus) are sexually segregated in different regions of the North Pacific Ocean and Bering Sea during their winter migration. Explanations for this involve interplay between physiology, predator-prey dynamics, and ecosystem characteristics, however possible mechanisms lack empirical support. To investigate factors influencing the winter ecology of both sexes, we deployed five satellite-linked conductivity, temperature, and depth data loggers on adult males, and six satellite-linked depth data loggers and four satellite transmitters on adult females from St. Paul Island (Bering Sea, Alaska, USA) in October 2009. Males and females migrated to different regions of the North Pacific Ocean: males wintered in the Bering Sea and northern North Pacific Ocean, while females migrated to the Gulf of Alaska and California Current. Horizontal and vertical movement behaviors of both sexes were influenced by wind speed, season, light (sun and moon), and the ecosystem they occupied, although the expression of the behaviors differed between sexes. Male dive depths were aligned with the depth of the mixed layer during daylight periods and we suspect this was the case for females upon their arrival to the California Current. We suggest that females, because of their smaller size and physiological limitations, must avoid severe winters typical of the northern North Pacific Ocean and Bering Sea and migrate long distances to areas of more benign environmental conditions and where prey is shallower and more accessible. In contrast, males can better tolerate often extreme winter ocean conditions and exploit prey at depth because of their greater size and physiological capabilities. We believe these contrasting winter behaviors 1) are a consequence of evolutionary selection for large size in males, important to the acquisition and defense of territories against rivals during the breeding season, and 2) ease environmental/physiological constraints imposed on smaller females. PMID:24722344
NASA Astrophysics Data System (ADS)
Grillo, Barbara; Braitenberg, Carla; Nagy, Ildikó; Devoti, Roberto; Zuliani, David; Fabris, Paolo
2018-05-01
Ten years' geodetic observations (2006-2016) in a natural cave of the Cansiglio Plateau (Bus de la Genziana), a limestone karstic area in northeastern Italy, are discussed. The area is of medium-high seismic risk: a strong earthquake in 1936 below the plateau ( M m = 6.2) and the 1976 disastrous Friuli earthquake ( M m = 6.5) are recent events. At the foothills of the karstic massif, three springs emerge, with average flow from 5 to 10 m3/s, and which are the sources of a river. The tiltmeter station is set in a natural cavity that is part of a karstic system. From March 2013, a multiparametric logger (temperature, stage, electrical conductivity) was installed in the siphon at the bottom of the cave to discover the underground hydrodynamics. The tilt records include signals induced by hydrologic and tectonic effects. The tiltmeter signals have a clear correlation to the rainfall, the discharge series of the river and the data recorded by multiparametric loggers. Additionally, the data of a permanent GPS station located on the southern slopes of the Cansiglio Massif (CANV) show also a clear correspondence with the river level. The fast water infiltration into the epikarst, closely related to daily rainfall, is distinguished in the tilt records from the characteristic time evolution of the karstic springs, which have an impulsive level increase with successive exponential decay. It demonstrates the usefulness of geodetic measurements to reveal the hydrological response of the karst. One outcome of the work is that the tiltmeters can be used as proxies for the presence of flow channels and the pressure that builds up due to the water flow. With 10 years of data, a new multidisciplinary frontier was opened between the geodetic studies and the karstic hydrogeology to obtain a more complete geologic description of the karst plateau.
NASA Astrophysics Data System (ADS)
Olds, S. E.; Mooney, M. E.; Dahlman, L. E.
2016-12-01
Recreational drones, also known as unmanned aerial vehicles (UAVs), provide an ideal platform for engaging students in science, technology, engineering, and math (STEM) investigations for science fair projects, after-school clubs, and in-class activities. UAVs are very popular (estimate of >1 million received as gifts this past year), relatively inexpensive (<$100), weigh less than 250g (don't require FAA registration), are modifiable, and can carry small instrument packages. Seeing the world from above can stimulate curiosity and give students a reason to engage in the Next Generation Science Standards (NGSS) process of science and engineering practices by designing and carrying out their own investigations. Using drones to facilitate experiments, students also participate in engineering design: they may choose off-the-shelf sensors or build DIY sensors to carry on their UAVs. Leveraging the learning potential of UAVs, the Federation of Earth Science Information Partners (ESIP) Education Committee has been developing an e-book of learning activities and investigation suggestions for secondary education students. The freely available download incorporates UAV civility and safety through a pre-flight checklist and flying guidelines, suggests science and flight team roles, and advocates robust data and metadata-collection practices. The ESIP team also worked with an engineer to build a 33-gram prototype environmental logger called SABEL (Shelley (Olds) and Bob's Environmental Logger). SABEL collects temperature, humidity, and GPS position assembled on an Arduino board. This presentation will elaborate upon the year-long process of working with educators via webinars and a 1-day workshop at the 2016 ESIP summer meeting and beyond. It will also provide examples of student-led investigations, instructions for building the SABEL sensor package, insights gleaned from workshop feedback - and - the status of the new e-book compilation of student-focused activities using recreational drones to pursue STEM investigations!
Sterling, Jeremy T; Springer, Alan M; Iverson, Sara J; Johnson, Shawn P; Pelland, Noel A; Johnson, Devin S; Lea, Mary-Anne; Bond, Nicholas A
2014-01-01
Adult male and female northern fur seals (Callorhinus ursinus) are sexually segregated in different regions of the North Pacific Ocean and Bering Sea during their winter migration. Explanations for this involve interplay between physiology, predator-prey dynamics, and ecosystem characteristics, however possible mechanisms lack empirical support. To investigate factors influencing the winter ecology of both sexes, we deployed five satellite-linked conductivity, temperature, and depth data loggers on adult males, and six satellite-linked depth data loggers and four satellite transmitters on adult females from St. Paul Island (Bering Sea, Alaska, USA) in October 2009. Males and females migrated to different regions of the North Pacific Ocean: males wintered in the Bering Sea and northern North Pacific Ocean, while females migrated to the Gulf of Alaska and California Current. Horizontal and vertical movement behaviors of both sexes were influenced by wind speed, season, light (sun and moon), and the ecosystem they occupied, although the expression of the behaviors differed between sexes. Male dive depths were aligned with the depth of the mixed layer during daylight periods and we suspect this was the case for females upon their arrival to the California Current. We suggest that females, because of their smaller size and physiological limitations, must avoid severe winters typical of the northern North Pacific Ocean and Bering Sea and migrate long distances to areas of more benign environmental conditions and where prey is shallower and more accessible. In contrast, males can better tolerate often extreme winter ocean conditions and exploit prey at depth because of their greater size and physiological capabilities. We believe these contrasting winter behaviors 1) are a consequence of evolutionary selection for large size in males, important to the acquisition and defense of territories against rivals during the breeding season, and 2) ease environmental/physiological constraints imposed on smaller females.
Cosmic-Ray Moisture Probe on North Slope of Alaska Field Campaign Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desilets, Darin
2016-06-15
In September of 2014 a wide-area snow monitoring device was installed at the U.S. Department of Energy (DOE)’s Barrow, Alaska Atmospheric Radiation Measurement (ARM) Climate Research Facility site. The device is special in that it uses measurements of cosmic-ray neutrons as a proxy for snow water equivalent (SWE) depth. A unique characteristic of the technology is that it integrates over a wide area (as much as 40 ha), in contrast to conventional ground-based technologies, which essentially give point samples. Conventional point-scale technologies are problematic in the Arctic, both because extreme weather conditions are taxing on equipment, and because point measurementsmore » can fail to accurately characterize the average SWE over a larger area, even when excellent precision is obtained. The sensor installed in Barrow is, by far, the northernmost of a constellation of sites that makeup the U.S. COsmic ray Soil Moisture Observing System (COSMOS). The sensor is used for SWE measurements in winter and soil moisture measurements in summer. The ability of this type of sensor to operate in the Arctic had not been verified until now. The cosmic-ray sensor was installed on a tripod located approximately 150 m south of the ARM User Facility (Figure 1), and within boundaries of land managed by the ARM Facility. The sensor consists of both “bare” and “moderated” channels, where the moderated channel is the primary output used to calculate SWE. A QDL2100 data logger with pressure sensor was located inside of the User Facility, and a Campbell CS215 temperature and humidity sensor was attached to a rail on the upper deck of the User Facility, to enable near-real-time absolute humidity corrections to the data. The cosmic-ray sensors are connected to the data logger using an armored Cat5e cable that lies on top of the tundra. Data are retrieved hourly via Iridium satellite link.« less
Body temperature and respiratory dynamics in un-shaded beef cattle
NASA Astrophysics Data System (ADS)
Gaughan, J. B.; Mader, T. L.
2014-09-01
In this study body temperature (BT, °C) and panting score (PS, 0-4.5; where 0 = no panting/no stress and 4.5 = catastrophic stress) data were obtained from 30 Angus steers housed outside over 120 days Steers were implanted with a BT transmitter on day -31, BT was recorded at 30-min intervals to a data logger and downloaded each day to a database. The cattle were housed in ten outdoor un-shaded pens with an earthen floor, eight of which had a pen floor area of 144 m2 (three transmitter steers plus five non-transmitter steers; 18 m2/steer) and two had an area of 168 m2 (three transmitter steers and six non-transmitter steers; 18.7 m2/steer). Only data from the transmitter steers were used in this study. The PS of the steers was obtained daily (± 15 min) at 0600 hours (AM), 1200 hours (MD) and 1600 hours (PM). At the same times climate variables (ambient temperature, black globe temperature, solar radiation, relative humidity, wind speed and rainfall) were obtained from an on-site weather station. PS observations were made from outside the pens so as not to influence cattle responses. The two closest BT values to the time when PS was obtained were downloaded retrospectively from a logger and averaged. A total of 8,352 observations were used to generate second order polynomial response curves: (AM) y = 39.08 + 0.009 x + 0.137 x 2 ( R 2 = 0.94; P < 0.001) (MD) y = 39.09 + 0.914 x - 0.080 x 2 ( R 2 = 0.89; P < 0.001) and (PM) y = 39.52 + 0.790 x - 0.068 x 2 ( R 2 = 0.83; P < 0.001) where y = BT (°C) and x PS. These data suggest that PS is a good indicator of body temperature. The BT at MD corresponded to slightly lower PS compared with PM, e.g., for PS 1; BT at MD = 39.1 ± 0.05 °C whereas BT at PM = 39.5 ± 0.05 °C. However during AM, BT was lower ( P < 0.05) at PS 1, 2 and 2.5 compared with MD and PM. For example, when PS was 2.5 the BT at AM was 40.2 ± 0.04 °C, at MD it was 40.9 ± 0.04 °C and at PM BT was 41.1 ± 0.04 °C. When PS was 0 the BT at AM and MD were similar. The AM response curve suggests animals attempt to increase heat dissipation during the cooler AM period relative to MD and PM. Morning observation of cattle (before feeding) are crucial for effective heat load management especially on days when high heat load is expected. The MD and PM observations provide a good indication of the impact of high environmental heat load on cattle. Differences in PS between AM and PM observations suggest that more research is needed to determine the effect of night time conditions on BT, PS and overall respiratory dynamics of cattle during periods of hot weather.
Feasibility of Bluetooth Data as a Surrogate Measure of Vehicle Operations
DOT National Transportation Integrated Search
2012-10-01
This research was designed as proof-of-concept study to investigate how Bluetooth data loggers can be used to collect vehicle : operational data over traditional vehicle counting methods. The reliability test included mapping areas for five antenna o...
Folksongs: Magic in Your Classroom.
ERIC Educational Resources Information Center
Seidman, Laurence I.
1985-01-01
Folksongs can be used with all students at all grade levels. Teacher guidelines are provided and three musical themes--whaling in New England, the California Gold Rush, and loggers and lumbering--are used to illustrate how to use folksongs in the classroom. (RM)
Fine resolution 3D temperature fields off Kerguelen from instrumented penguins
NASA Astrophysics Data System (ADS)
Charrassin, Jean-Benoît; Park, Young-Hyang; Le Maho, Yvon; Bost, Charles-André
2004-12-01
The use of diving animals as autonomous vectors of oceanographic instruments is rapidly increasing, because this approach yields cost-efficient new information and can be used in previously poorly sampled areas. However, methods for analyzing the collected data are still under development. In particular, difficulties may arise from the heterogeneous data distribution linked to animals' behavior. Here we show how raw temperature data collected by penguin-borne loggers were transformed to a regular gridded dataset that provided new information on the local circulation off Kerguelen. A total of 16 king penguins ( Aptenodytes patagonicus) were equipped with satellite-positioning transmitters and with temperature-time-depth recorders (TTDRs) to record dive depth and sea temperature. The penguins' foraging trips recorded during five summers ranged from 140 to 600 km from the colony and 11,000 dives >100 m were recorded. Temperature measurements recorded during diving were used to produce detailed 3D temperature fields of the area (0-200 m). The data treatment included dive location, determination of the vertical profile for each dive, averaging and gridding of those profiles onto 0.1°×0.1° cells, and optimal interpolation in both the horizontal and vertical using an objective analysis. Horizontal fields of temperature at the surface and 100 m are presented, as well as a vertical section along the main foraging direction of the penguins. Compared to conventional temperature databases (Levitus World Ocean Atlas and historical stations available in the area), the 3D temperature fields collected from penguins are extremely finely resolved, by one order finer. Although TTDRs were less accurate than conventional instruments, such a high spatial resolution of penguin-derived data provided unprecedented detailed information on the upper level circulation pattern east of Kerguelen, as well as the iron-enrichment mechanism leading to a high primary production over the Kerguelen Plateau.
Hetem, Robyn Sheila; Strauss, Willem Maartin; Fick, Linda Gayle; Maloney, Shane Kevin; Meyer, Leith Carl Rodney; Shobrak, Mohammed; Fuller, Andrea; Mitchell, Duncan
2012-04-01
Heterothermy, a variability in body temperature beyond the normal limits of homeothermy, is widely viewed as a key adaptation of arid-adapted ungulates. However, desert ungulates with a small body mass, i.e. a relatively large surface area-to-volume ratio and a small thermal inertia, are theoretically less likely to employ adaptive heterothermy than are larger ungulates. We measured body temperature and activity patterns, using implanted data loggers, in free-ranging Arabian oryx (Oryx leucoryx, ±70 kg) and the smaller Arabian sand gazelle (Gazella subgutturosa marica, ±15 kg) inhabiting the same Arabian desert environment, at the same time. Compared to oryx, sand gazelle had higher mean daily body temperatures (F(1,6) = 47.3, P = 0.0005), higher minimum daily body temperatures (F(1,6) = 42.6, P = 0.0006) and higher maximum daily body temperatures (F(1,6) = 11.0, P = 0.02). Despite these differences, both species responded similarly to changes in environmental conditions. As predicted for adaptive heterothermy, maximum daily body temperature increased (F(1,6) = 84.0, P < 0.0001), minimum daily body temperature decreased (F(1,6) = 92.2, P < 0.0001), and daily body temperature amplitude increased (F(1,6) = 97.6, P < 0.0001) as conditions got progressively hotter and drier. There were no species differences in activity levels, however, both gazelle and oryx showed a biphasic or crepuscular rhythm during the warm wet season but shifted to a more nocturnal rhythm during the hot dry season. Activity was attenuated during the heat of the day at times when both species selected cool microclimates. These two species of Arabian ungulates employ heterothermy, cathemerality and shade seeking very similarly to survive the extreme, arid conditions of Arabian deserts, despite their size difference.
MELIFT - A new device for accurate measurements in a snow rich environment
NASA Astrophysics Data System (ADS)
Dorninger, M.
2012-04-01
A deep snow pack, remote locations, no external power supply and very low temperatures are often the main ingredients when it comes to the deployment of meteorological stations in mountainous terrain. The accurate position of the sensor related to the snow surface is normally not known. A new device called METLIFT overcomes the problems. WMO recommends a height between 1.2 m and 2 m above ground level for the measurement of air temperature and humidity. The height above ground level is specified to take care of the possible strong vertical temperature and humidity gradients at the lowest layers in the atmosphere. Especially in snow rich and remote locations it may be hardly possible to follow this advice. Therefore most of the meteorological stations in mountainous terrain are situated at mountain tops where strong winds will blow off the snow or in valleys where a daily inspection of the sensors is possible. In other unpopulated mountainous areas, e.g. basins, plateaus, the distance of the sensor to the snow surface is not known or the sensor will be snow-covered. A new device was developed to guarantee the sensor height above surface within the WMO limits in harsh and remote environments. An ultrasonic snow height sensor measures the distance to the snow surface. If it exceeds certain limits due to snow accumulation or snow melt the lift adapts its height accordingly. The prototype of METLIFT has been installed in Lower Austria at an altitude of 1000m. The lift is 6 m high and can pull out for another 4 m. Sensor arms are mounted every meter to allow the connection of additional sensors or to measure a profile of a certain parameter of the lowest 5 m above surface. Sensors can be added easily since cable wiring is provided to each sensor arm. Horizontal winds are measured at 7 m height above surface. METLIFT is independent of external power supply. Three lead gel accumulators recharged by three solar panels provide the energy necessary for the sensors, the data loggers, the data transmission components and for the electromotor to lift the system. METLIFT is energy optimised to keep the energy consumption at low levels. The components of the lift device consist of a 12V electromotor with a worm gear with a transmission rate of 2856:1. This means that the lift moves extremely slow. The data logger can be programmed via the GSM connection from remote locations, the data flow is also conducted via this connection. First results of the winter campaign 2011/2012 will be presented at the conference.
NASA Astrophysics Data System (ADS)
Cristea, N. C.; Burges, S. J.
2004-12-01
The stream water spatial and temporal temperature patterns of the Wenatchee River, WA are assessed based on temperature data recorded by instream data loggers in the dry season of 2002 and thermal infrared imagery from August 16th 2002. To gain insights into the possible thermal behavior of the river, the stream temperature model Qual2K (Chapra and Pelletier, 2003) is extended beyond its calibration (10-16 August 2002) and confirmation (9-11 September 2002) periods for use with different meteorological, shade and flow conditions. The temperature longitudinal profile of the Wenatchee River is influenced by the temperature regime in Lake Wenatchee, the source of the Wenatchee River. Model simulations performed at 7-day average with 2-year return period flow conditions show that the potential (maximum average across all reaches) temperature (the temperature that would occur under natural conditions) is about 19.8 deg. C. For the 7-day average with 10-year return period flow conditions the potential temperature increases to about 21.2 deg. C. The simulation results show that under normal flow and meteorological conditions the water temperature exceeds the current water quality standards. Model simulations performed under the 7-day average with 10-year return period flow conditions and a climate change scenario show that the average potential temperature across all reaches can increase by as much as 1.3 deg. C compared to the case where climate change impact is not taken into account. Thermal infrared (TIR) derived stream temperature data were useful for describing spatial distribution patterns of the Wenatchee River water temperature. The TIR and visible band images are effective tools to map cold water refugia for fish and to detect regions that can be improved for fish survival. The images collected during the TIR survey and the TIR derived stream temperature longitudinal profile helps pinpoint additional instream monitoring locations that avoid regions of backwater, cool or warm pockets or regions affected by tributary influence, that are inappropriate for stream temperature monitoring. Groundwater input is difficult to detect from the TIR images in the case of a relatively large river such the Wenatchee River.
"Artificial intelligence" at streamgaging stations
R. B. Thomas
1985-01-01
Two types of problems are related to collecting hydrologic data at stream gaging stations. One includes the technical/logistical questions associated with measuring and transferring data for processing. Effort spent on these problems ranges from improving devices for sensing data to using electronic data loggers.
Broell, Franziska; Burnell, Celene; Taggart, Christopher T
2016-03-01
Animal-borne data loggers allow movement, associated behaviours and energy expenditure in fish to be quantified without direct observations. As with any tagging, tags that are attached externally may adversely affect fish behaviour, swimming efficiency and survival. We report on free-swimming wild Atlantic cod (Gadus morhua) held in a large mesocosm that exhibited distinctly aberrant rotational swimming (scouring) when externally tagged with accelerometer data loggers. To quantify the phenomenon, the cod were tagged with two sizes of loggers (18 and 6 g; <2% body mass) that measured tri-axial acceleration at 50 Hz. An automated algorithm, based on body angular rotation, was designed to extract the scouring movements from the acceleration signal (98% accuracy). The algorithm also identified the frequency pattern and associated energy expenditure of scouring in relation to tag load (% body weight). The average per cent time spent scouring (5%) was independent of tag load. The vector of the dynamic body acceleration (VeDBA), used as a proxy for energy expenditure, increased with tag load (r(2)=0.51), and suggests that fish with large tags spent more energy when scouring than fish with small tags. The information allowed us to determine potential detrimental effects of an external tag on fish behaviour and how these effects may be mitigated by tag size. The algorithm can potentially identify similar rotational movements associated with spawning, courtship, feeding and parasite-load shedding in the wild. The results infer a more careful interpretation of data derived from external tags and the careful consideration of tag type, drag, buoyancy and placement, as well as animal buoyancy and species. © 2016. Published by The Company of Biologists Ltd.
Creative Uses of Custom Electronics for Environmental Monitoring
NASA Astrophysics Data System (ADS)
Hicks, S.; Aufdenkampe, A. K.; Montgomery, D. S.
2012-12-01
The ability to build custom electronic devices specifically suited to a unique task has gotten easier and cheaper, thanks to the recent popularity of open source electronics platforms like Arduino. Using Arduino-based processor boards, we have been creating a variety of helpful devices to perform functions that would have been too expensive to implement with standard methods and commercial hardware. The Christina River Basin CZO is currently operating dozens of homemade dataloggers that are connected to different types of environmental sensors. Most of these Arduino loggers have been deployed for over a year, so our experiences with them and their sensors have taught us a lot about the reliability and accuracy of both the loggers and the sensors. Some loggers also have the capability for wireless radio or ethernet data transmission for reporting live data to web sites for instant graphing or archiving. Other Arduino devices have the ability to be controlled remotely through web sites or telephones, making it easy to remotely trigger sample pumps or valves. The open-source nature of Arduino means collaboration is easy because the circuit schematics and source code for programming the boards can be shared between users. And because Arduino devices are easy to use and program, we developed an interface board that allows educators to easily connect a variety of inexpensive environmental sensors to an Arduino board. Then the students can write and upload simple programs to interact with the sensors, making it a very effective tool for teaching electronics and environmental science at the same time. The flexibility and capability of electronics prototyping platforms like Arduino mean these simple boards can cheaply and effectively perform a countless number of tasks for projects in environmental science and education.
Shipboard Analytical Capabilities on the Renovated JOIDES Resolution, IODP Riserless Drilling Vessel
NASA Astrophysics Data System (ADS)
Blum, P.; Foster, P.; Houpt, D.; Bennight, C.; Brandt, L.; Cobine, T.; Crawford, W.; Fackler, D.; Fujine, K.; Hastedt, M.; Hornbacher, D.; Mateo, Z.; Moortgat, E.; Vasilyev, M.; Vasilyeva, Y.; Zeliadt, S.; Zhao, J.
2008-12-01
The JOIDES Resolution (JR) has conducted 121 scientific drilling expeditions during the Ocean Drilling Program (ODP) and the first phase of the Integrated Ocean Drilling Program (IODP) (1983-2006). The vessel and scientific systems have just completed an NSF-sponsored renovation (2005-2008). Shipboard analytical systems have been upgraded, within funding constraints imposed by market driven vessel conversion cost increases, to include: (1) enhanced shipboard analytical services including instruments and software for sampling and the capture of chemistry, physical properties, and geological data; (2) new data management capabilities built around a laboratory information management system (LIMS), digital asset management system, and web services; (3) operations data services with enhanced access to navigation and rig instrumentation data; and (4) a combination of commercial and home-made user applications for workflow- specific data extractions, generic and customized data reporting, and data visualization within a shipboard production environment. The instrumented data capture systems include a new set of core loggers for rapid and non-destructive acquisition of images and other physical properties data from drill cores. Line-scan imaging and natural gamma ray loggers capture data at unprecedented quality due to new and innovative designs. Many instruments used to characterize chemical compounds of rocks, sediments, and interstitial fluids were upgraded with the latest technology. The shipboard analytical environment features a new and innovative framework (DESCinfo) and application (DESClogik) for capturing descriptive and interpretive data from geological sub-domains such as sedimentology, petrology, paleontology, structural geology, stratigraphy, etc. This system fills a long-standing gap by providing a global database, controlled vocabularies and taxa name lists with version control, a highly configurable spreadsheet environment for data capture, and visualization of context data collected with the shipboard core loggers and other instruments.
Levin, Iris I.; Zonana, David M.; Burt, John M.; Safran, Rebecca J.
2015-01-01
Proximity logging is a new tool for understanding social behavior as it allows for accurate quantification of social networks. We report results from field calibration and deployment tests of miniaturized proximity tags (Encounternet), digital transceivers that log encounters between tagged individuals. We examined radio signal behavior in relation to tag attachment (tag, tag on bird, tag on saline-filled balloon) to understand how radio signal strength is affected by the tag mounting technique used for calibration tests. We investigated inter-tag and inter-receiver station variability, and in each calibration test we accounted for the effects of antennae orientation. Additionally, we used data from a live deployment on breeding barn swallows (Hirundo rustica erythrogaster) to analyze the quality of the logs, including reciprocal agreement in dyadic logs. We evaluated the impact (in terms of mass changes) of tag attachment on the birds. We were able to statistically distinguish between RSSI values associated with different close-proximity (<5m) tag-tag distances regardless of antennae orientation. Inter-tag variability was low, but we did find significant inter-receiver station variability. Reciprocal agreement of dyadic logs was high and social networks were constructed from proximity tag logs based on two different RSSI thresholds. There was no evidence of significant mass loss in the time birds were wearing tags. We conclude that proximity loggers are accurate and effective for quantifying social behavior. However, because RSSI and distance cannot be perfectly resolved, data from proximity loggers are most appropriate for comparing networks based on specific RSSI thresholds. The Encounternet system is flexible and customizable, and tags are now light enough for use on small animals (<50g). PMID:26348329
Ellis, M; Manandhar, N; Shakya, U; Manandhar, D S; Fawdry, A; Costello, A M
1996-07-01
To describe the pattern of hypothermia and cold stress after delivery among a normal neonatal population in Nepal; to provide practical advice for improving thermal care in a resource limited maternity hospital. The principal government funded maternity hospital in Kathmandu, Nepal, with an annual delivery rate of 15,000 (constituting 40% of all Kathmandu Valley deliveries), severe resource limitations (annual budget Pounds 250,000), and a cold winter climate provided the setting. Thirty five healthy term neonates not requiring special care were enrolled for study within 90 minutes of birth. Continuous ambulatory temperature monitoring, using microthermistor skin probes for forehead and axilla, a flexible rectal probe, and a black ball probe placed next to the infant for ambient temperature, was carried out. All probes were connected to a compact battery powered Squirrel Memory Logger, giving a temperature reading to 0.2 degree C at five minute intervals for 24 hours. Severity and duration of hypothermia, using cutoff values of core temperature less than 36 degrees C, 34 degrees C, and 32 degrees C; and cold stress, using cutoff values of skin-core (forehead-axilla) temperature difference greater than 3 degrees C and 4 degrees C were the main outcome measures. Twenty four hour mean ambient temperatures were generally lower than the WHO recommended level of 25 degrees C (median 22.3 degrees C, range 15.1-27.5 degrees C). Postnatal hypothermia was prolonged, with axillary core temperatures only reaching 36 degrees C after a mean of 6.4 hours (range 0-21.1; SD 4.6). There was persistent and increasing cold stress over the first 24 hours with the core-skin (axillary-forehead) temperature gap exceeding 3 degrees C for more than half of the first 24 hours. Continuous ambulatory recording identifies weak links in the "warm chain" for neonates. The severity and duration of thermal problems was greater than expected even in a hospital setting where some of the WHO recommendations had already been implemented.
Rebaudo, François; Faye, Emile; Dangles, Olivier
2016-01-01
A large body of literature has recently recognized the role of microclimates in controlling the physiology and ecology of species, yet the relevance of fine-scale climatic data for modeling species performance and distribution remains a matter of debate. Using a 6-year monitoring of three potato moth species, major crop pests in the tropical Andes, we asked whether the spatiotemporal resolution of temperature data affect the predictions of models of moth performance and distribution. For this, we used three different climatic data sets: (i) the WorldClim dataset (global dataset), (ii) air temperature recorded using data loggers (weather station dataset), and (iii) air crop canopy temperature (microclimate dataset). We developed a statistical procedure to calibrate all datasets to monthly and yearly variation in temperatures, while keeping both spatial and temporal variances (air monthly temperature at 1 km² for the WorldClim dataset, air hourly temperature for the weather station, and air minute temperature over 250 m radius disks for the microclimate dataset). Then, we computed pest performances based on these three datasets. Results for temperature ranging from 9 to 11°C revealed discrepancies in the simulation outputs in both survival and development rates depending on the spatiotemporal resolution of the temperature dataset. Temperature and simulated pest performances were then combined into multiple linear regression models to compare predicted vs. field data. We used an additional set of study sites to test the ability of the results of our model to be extrapolated over larger scales. Results showed that the model implemented with microclimatic data best predicted observed pest abundances for our study sites, but was less accurate than the global dataset model when performed at larger scales. Our simulations therefore stress the importance to consider different temperature datasets depending on the issue to be solved in order to accurately predict species abundances. In conclusion, keeping in mind that the mismatch between the size of organisms and the scale at which climate data are collected and modeled remains a key issue, temperature dataset selection should be balanced by the desired output spatiotemporal scale for better predicting pest dynamics and developing efficient pest management strategies.
Rebaudo, François; Faye, Emile; Dangles, Olivier
2016-01-01
A large body of literature has recently recognized the role of microclimates in controlling the physiology and ecology of species, yet the relevance of fine-scale climatic data for modeling species performance and distribution remains a matter of debate. Using a 6-year monitoring of three potato moth species, major crop pests in the tropical Andes, we asked whether the spatiotemporal resolution of temperature data affect the predictions of models of moth performance and distribution. For this, we used three different climatic data sets: (i) the WorldClim dataset (global dataset), (ii) air temperature recorded using data loggers (weather station dataset), and (iii) air crop canopy temperature (microclimate dataset). We developed a statistical procedure to calibrate all datasets to monthly and yearly variation in temperatures, while keeping both spatial and temporal variances (air monthly temperature at 1 km² for the WorldClim dataset, air hourly temperature for the weather station, and air minute temperature over 250 m radius disks for the microclimate dataset). Then, we computed pest performances based on these three datasets. Results for temperature ranging from 9 to 11°C revealed discrepancies in the simulation outputs in both survival and development rates depending on the spatiotemporal resolution of the temperature dataset. Temperature and simulated pest performances were then combined into multiple linear regression models to compare predicted vs. field data. We used an additional set of study sites to test the ability of the results of our model to be extrapolated over larger scales. Results showed that the model implemented with microclimatic data best predicted observed pest abundances for our study sites, but was less accurate than the global dataset model when performed at larger scales. Our simulations therefore stress the importance to consider different temperature datasets depending on the issue to be solved in order to accurately predict species abundances. In conclusion, keeping in mind that the mismatch between the size of organisms and the scale at which climate data are collected and modeled remains a key issue, temperature dataset selection should be balanced by the desired output spatiotemporal scale for better predicting pest dynamics and developing efficient pest management strategies. PMID:27148077
Tax tips for forest landowners for the 2008 tax year
Linda Wang; John L. Greene
2009-01-01
This article summarizes key federal income tax provisions for forestland owners, foresters, loggers, forest product businesses, and tax practioners, and is current as of October 1, 2008. Consult your tax and legal professionals for advice on your particular tax situation.
ERIC Educational Resources Information Center
Daniels, Elva S.
1983-01-01
A teaching unit uses the songs of sailors, loggers, coal miners, and other workers to illustrate how the United States was built in the nineteenth century. Words and music for seven songs are given, along with classroom activities to help children understand occupations and industries during that time. (PP)
Monitoring tools of COMPASS experiment at CERN
NASA Astrophysics Data System (ADS)
Bodlak, M.; Frolov, V.; Huber, S.; Jary, V.; Konorov, I.; Levit, D.; Novy, J.; Salac, R.; Tomsa, J.; Virius, M.
2015-12-01
This paper briefly introduces the data acquisition system of the COMPASS experiment and is mainly focused on the part that is responsible for the monitoring of the nodes in the whole newly developed data acquisition system of this experiment. The COMPASS is a high energy particle experiment with a fixed target located at the SPS of the CERN laboratory in Geneva, Switzerland. The hardware of the data acquisition system has been upgraded to use FPGA cards that are responsible for data multiplexing and event building. The software counterpart of the system includes several processes deployed in heterogenous network environment. There are two processes, namely Message Logger and Message Browser, taking care of monitoring. These tools handle messages generated by nodes in the system. While Message Logger collects and saves messages to the database, the Message Browser serves as a graphical interface over the database containing these messages. For better performance, certain database optimizations have been used. Lastly, results of performance tests are presented.
The NASA rocky mountain space grant high altitude research balloon project
NASA Astrophysics Data System (ADS)
Moore, R. G.; Espy, P.
1994-02-01
A group of U.S. universities, under the auspices of NASA's Space Grant College and Fellowship Program, has initiated a super-pressure balloon research project to measure ozone column density in the atmosphere above 20 kilometers, together with stratospheric circulation between 20 km and 40 km, over the continental U.S.A. Data from a balloon-borne ultraviolet spectrometer, together with time, altitude, latitude and longitude information from a Global Positioning System receiver, are recorded at ten-minute intervals during daytime hours in an on-board solid-state data logger. Coded messages are transmitted nightly from selected amateur radio ground stations to a receiver in the balloon gondola to command the transmission of packet radio bursts from the data logger to the ground stations, for relay to a central data collection and analysis facility at Utah State University. Discussions are under way with radio amateurs and members of the international scientific balloon community regarding extension of flights to cover the earth's northern hemisphere.
The NASA rocky moutain space grant high altitude research balloon project
NASA Astrophysics Data System (ADS)
Moore, R. G.; Espy, P.
1994-02-01
A group of U.S. universities, under the auspices of NASA's Space Grant College and Fellowship Program, has initiated a super-pressure balloon research project to measure ozone column density in the atmosphere above 20 kilometers, together with stratospheric circulation between 20 km and 40 km, over the continental U.S.A. Data from a balloon-borne ultraviolet spectrometer, together with time, altitude, latitude and longitude information from a Global Positioning System reciever, are recorded at ten-minute intervals during daytime hours in an on-board solid-state data logger. Coded messages are transmitted nightly from selected amateur radio ground stations to a receiver in the balloon gondola to command transmission of packet radio bursts from the data logger to the ground stations, for relay to a central data collection and analysis facility at Utah State University. Discussions are under way with radio amateurs and members of the international scientific balloon community regarding extension of flights to cover the earth's northern hemisphere.
Enstipp, Manfred R; Bost, Charles-André; Le Bohec, Céline; Bost, Caroline; Le Maho, Yvon; Weimerskirch, Henri; Handrich, Yves
2017-07-15
Little is known about the early life at sea of marine top predators, like deep-diving king penguins ( Aptenodytes patagonicus ), although this dispersal phase is probably a critical phase in their life. Apart from finding favourable foraging sites, they have to develop effective prey search patterns as well as physiological capacities that enable them to capture sufficient prey to meet their energetic needs. To investigate the ontogeny of their thermoregulatory responses at sea, we implanted 30 juvenile king penguins and 8 adult breeders with a small data logger that recorded pressure and subcutaneous temperature continuously for up to 2.5 years. We found important changes in the development of peripheral temperature patterns of foraging juvenile king penguins throughout their first year at sea. Peripheral temperature during foraging bouts fell to increasingly lower levels during the first 6 months at sea, after which it stabilized. Most importantly, these changes re-occurred during their second year at sea, after birds had fasted for ∼4 weeks on land during their second moult. Furthermore, similar peripheral temperature patterns were also present in adult birds during foraging trips throughout their breeding cycle. We suggest that rather than being a simple consequence of concurrent changes in dive effort or an indication of a physiological maturation process, these seasonal temperature changes mainly reflect differences in thermal insulation. Heat loss estimates for juveniles at sea were initially high but declined to approximately half after ∼6 months at sea, suggesting that juvenile king penguins face a strong energetic challenge during their early oceanic existence. © 2017. Published by The Company of Biologists Ltd.
Testing the fidelity of the Sr/Ca proxy in recording ocean temperature in a western Atlantic coral
NASA Astrophysics Data System (ADS)
Kuffner, I. B.; Roberts, K.; Flannery, J. A.; Richey, J. N.; Morrison, J. M.
2017-12-01
Massive corals provide a useful archive of environmental variability, but careful testing of geochemical proxies in corals is necessary to validate the relationship between each proxy and environmental parameter throughout the full range of conditions experienced by the recording organisms. Here we use samples from a field-based coral-growth study to test the hypothesis that Sr/Ca in the coral Siderastrea siderea accurately records sea-surface temperature (SST) in the subtropics (Florida, USA) along 350 km of reef tract. We test calcification rate, measured via buoyant weight, and linear extension (LE) rate, estimated with Alizarin Red-S staining, as predictors of variance in the Sr/Ca records of 39 individual S. siderea corals grown at four outer-reef locations next to in-situ temperature loggers during two, year-long periods. We found that corals with calcification rates less than 1.7 mg cm-2 d-1 or LE rates less than 1.7 mm yr-1 returned spuriously high Sr/Ca values, leading to a cold bias in Sr/Ca-based SST estimates. The threshold-type response curves suggest that LE rate can be used as a quality-control indicator during sample and microdrill-path selection when using long cores for SST paleoreconstruction. For our corals that passed this quality control step, the Sr/Ca-SST proxy performed well in estimating mean annual SST across three sites spanning 350 km of the Florida reef tract. However, there was some evidence that extreme temperature stress in 2010 (cold snap) and 2011 (SST above coral-bleaching threshold) may have caused the corals not to record the temperature extremes. Known stress events could be avoided during modern calibrations of paleoproxies.
Estradiol alters body temperature regulation in the female mouse.
Krajewski-Hall, Sally J; Blackmore, Elise M; McMinn, Jessi R; Rance, Naomi E
2018-01-01
Hot flushes are due to estrogen withdrawal and characterized by the episodic activation of heat dissipation effectors. Recent studies (in humans and rats) have implicated neurokinin 3 (NK 3 ) receptor signaling in the genesis of hot flushes. Although transgenic mice are increasingly used for biomedical research, there is limited information on how 17β-estradiol and NK 3 receptor signaling alters thermoregulation in the mouse. In this study, a method was developed to measure tail skin temperature (T SKIN ) using a small data-logger attached to the surface of the tail, which, when combined with a telemetry probe for core temperature (T CORE ), allowed us to monitor thermoregulation in freely-moving mice over long durations. We report that estradiol treatment of ovariectomized mice reduced T CORE during the light phase (but not the dark phase) while having no effect on T SKIN or activity. Estradiol also lowered T CORE in mice exposed to ambient temperatures ranging from 20 to 36°C. Unlike previous studies in the rat, estradiol treatment of ovariectomized mice did not reduce T SKIN during the dark phase. Subcutaneous injections of an NK 3 receptor agonist (senktide) in ovariectomized mice caused an acute increase in T SKIN and a reduction in T CORE , consistent with the activation of heat dissipation effectors. These changes were reduced by estradiol, suggesting that estradiol lowers the sensitivity of central thermoregulatory pathways to NK 3 receptor activation. Overall, we show that estradiol treatment of ovariectomized mice decreases T CORE during the light phase, reduces the thermoregulatory effects of senktide and modulates thermoregulation differently than previously described in the rat.
Ernst, Anne G.; Baldigo, Barry P.; Calef, Fred J.; Freehafer, Douglas A.; Kremens, Robert L.
2015-10-09
The locations and sizes of potential cold-water refuges for trout were examined in 2005 along a 27-kilometer segment of the Indian and Hudson Rivers in northern New York to evaluate the extent of refuges, the effects of routine flow releases from an impoundment, and how these refuges and releases might influence trout survival in reaches that otherwise would be thermally stressed. This river segment supports small populations of brook trout (Salvelinus fontinalis), brown trout (Salmo trutta), and rainbow trout (Oncorhynchus mykiss) and also receives regular releases of reservoir-surface waters to support rafting during the summer, when water temperatures in both the reservoir and the river frequently exceed thermal thresholds for trout survival. Airborne thermal infrared imaging was supplemented with continuous, in-stream temperature loggers to identify potential refuges that may be associated with tributary inflows or groundwater seeps and to define the extent to which the release flows decrease the size of existing refuges. In general, the release flows overwhelmed the refuge areas and greatly decreased the size and number of the areas. Mean water temperatures were unaffected by the releases, but small-scale heterogeneity was diminished. At a larger scale, water temperatures in the upper and lower segments of the reach were consistently warmer than in the middle segment, even during passage of release waters. The inability of remote thermal infrared images to consistently distinguish land from water (in shaded areas) and to detect groundwater seeps (away from the shallow edges of the stream) limited data analysis and the ability to identify potential thermal refuge areas.
Twining, Brian V.; Rattray, Gordon W.
2016-11-02
The Camas National Wildlife Refuge (Refuge) in eastern Idaho, established in 1937, contains wetlands, ponds, and wet meadows that are essential resting and feeding habitat for migratory birds and nesting habitat for waterfowl. Initially, natural sources of water supported these habitats. However, during the past few decades, climate change and changes in surrounding land use have altered and reduced natural groundwater and surface water inflows such that the wetlands, ponds, and wet meadows are now maintained through water management and groundwater pumping. These water management activities have proven to be inefficient and costly, prompting the Refuge to develop alternative water management options that are more efficient and less expensive. The U.S. Geological Survey, in cooperation with the U.S. Fish and Wildlife Service, is studying the hydrogeology at the Refuge to provide information for developing alternative water management options.The hydrogeologic studies at the Refuge included characterizing the type, distribution, and hydraulic conductivity of surficial sediments and measuring water levels and temperatures in monitoring wells. Four monitoring wells and seven soil probe coreholes were drilled at the Refuge. Seven water level and temperature data loggers were installed in the wells and water levels and temperatures were continuously recorded from November 2014 to June 2016. Sediment cores were collected from the coreholes and sediment type and distribution were characterized from drillers’ notes, geophysical logs, corehole samples, and particle grain-size analysis. The hydraulic conductivities of sediments were estimated using the measured average grain size and the assumed textural maturity of the sediment, and ranged from about 20 to 290 feet per day.
Extreme Marine Warming Across Tropical Australia During Austral Summer 2015-2016
NASA Astrophysics Data System (ADS)
Benthuysen, Jessica A.; Oliver, Eric C. J.; Feng, Ming; Marshall, Andrew G.
2018-02-01
During austral summer 2015-2016, prolonged extreme ocean warming events, known as marine heatwaves (MHWs), occurred in the waters around tropical Australia. MHWs arose first in the southeast tropical Indian Ocean in November 2015, emerging progressively east until March 2016, when all waters from the North West Shelf to the Coral Sea were affected. The MHW maximum intensity tended to occur in March, coinciding with the timing of the maximum sea surface temperature (SST). Large areas were in a MHW state for 3-4 months continuously with maximum intensities over 2°C. In 2016, the Indonesian-Australian Basin and areas including the Timor Sea and Kimberley shelf experienced the longest and most intense MHW from remotely sensed SST dating back to 1982. In situ temperature data from temperature loggers at coastal sites revealed a consistent picture, with MHWs appearing from west to east and peaking in March 2016. Temperature data from moorings, an Argo float, and Slocum gliders showed the extent of warming with depth. The events occurred during a strong El Niño and weakened monsoon activity, enhanced by the extended suppressed phase of the Madden-Julian Oscillation. Reduced cloud cover in January and February 2016 led to positive air-sea heat flux anomalies into the ocean, predominantly due to the shortwave radiation contribution with a smaller additional contribution from the latent heat flux anomalies. A data-assimilating ocean model showed regional changes in the upper ocean circulation and a change in summer surface mixed layer depths and barrier layer thicknesses consistent with past El Niño events.
Design and realization of an automatic weather station at island
NASA Astrophysics Data System (ADS)
Chen, Yong-hua; Li, Si-ren
2011-10-01
In this paper, the design and development of an automatic weather station monitoring is described. The proposed system consists of a set of sensors for measuring meteorological parameters (temperature, wind speed & direction, rain fall, visibility, etc.). To increase the reliability of the system, wind speed & direction are measured redundantly with duplicate sensors. The sensor signals are collected by the data logger CR1000 at several analog and digital inputs. The CR1000 and the sensors form a completely autonomous system which works with the other systems installed in the container. Communication with the master PC is accomplished over the method of Code Division Multiple Access (CDMA) with the Compact Caimore6550P CDMA DTU. The data are finally stored in tables on the CPU as well as on the CF-Card. The weather station was built as an efficient autonomous system which operates with the other systems to provide the required data for a fully automatic measurement system.
NASA Astrophysics Data System (ADS)
Misra, R. K.; Padhi, J.; Payero, J. O.
2011-08-01
SummaryWe used twelve load cells (20 kg capacity) in a mini-lysimeter system to measure evapotranspiration simultaneously from twelve plants growing in separate pots in a glasshouse. A data logger combined with a multiplexer was used to connect all load cells with the full-bridge excitation mode to acquire load-cell signal. Each load cell was calibrated using fixed load within the range of 0-0.8 times the full load capacity of load cells. Performance of all load cells was assessed on the basis of signal settling time, excitation compensation, hysteresis and temperature. Final calibration of load cells included statistical consideration of these effects to allow prediction of lysimeter weights and evapotranspiration over short-time intervals for improved accuracy and sustained performance. Analysis of the costs for the mini-lysimeter system indicates that evapotranspiration can be measured economically at a reasonable accuracy and sufficient resolution with robust method of load-cell calibration.
Seasonal and diel patterns in cetacean use and foraging at a potential marine renewable energy site.
Nuuttila, Hanna K; Bertelli, Chiara M; Mendzil, Anouska; Dearle, Nessa
2018-04-01
Marine renewable energy (MRE) developments often coincide with sites frequented by small cetaceans. To understand habitat use and assess potential impact from development, echolocation clicks were recorded with acoustic click loggers (C-PODs) in Swansea Bay, Wales (UK). General Additive Models (GAMs) were applied to assess the effects of covariates including month, hour, tidal range and temperature. Analysis of inter-click intervals allowed the identification of potential foraging events as well as patterns of presence and absence. Data revealed year-round presence of porpoise, with distinct seasonal and diel patterns. Occasional acoustic encounters of dolphins were also recorded. This study provides further evidence of the need for assessing temporal trends in cetacean presence and habitat use in areas considered for development. These findings could assist MRE companies to monitor and mitigate against disturbance from construction, operation and decommissioning activities by avoiding times when porpoise presence and foraging activity is highest in the area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Szymański, Marcin; Morshed, Kamal; Mills, Robert P
2007-01-01
The aim of the study was to assess the effect of CO(2) laser on stapes prostheses and measure the heat transmission to the vestibule in experiment model. CO(2) laser was applied on two types of prostheses with power settings (2 and 6W; 0.05 s). Transmission of heat to the 'vestibule' was measured using type K thermocouple and DC-80 data logger during application of the laser on prostheses using a training model of temporal bone. Application of the laser on stainless steel prosthesis did not have any effect on the structure of the prosthesis. The use of the laser on the fluoroplastic-wire piston caused melting and produced holes in the piston. Greater temperature rises occurred with stainless steel than with the fluoroplastic-wire piston. Application of CO(2) laser on stainless steel pistons with 6W can produce inner ear trauma. The use of the laser on fluoroplastic-wire piston is not likely to irritate the inner ear.
Characterising meso-marine ecosystems of the North Pacific
NASA Astrophysics Data System (ADS)
Batten, Sonia D.; David Hyrenbach, K.; Sydeman, William J.; Morgan, Ken H.; Henry, Michael F.; Yen, Peggy P. Y.; Welch, David W.
2006-02-01
To delineate mesoscale variability in marine ecosystems of the subarctic North Pacific and identify "hotspots" of biological activity, we conducted contemporaneous surveys of plankton and avifaunal communites in 2000-2003. Plankton samples were collected with a continuous plankton recorder (CPR) towed by a commercial vessel while a trained observer recorded marine bird distributions using strip-transect techniques. Near- and sub-surface physical oceanographic properties and productivity patterns were measured using a temperature data logger and satellite-derived chlorophyll a concentrations. We identified 10 distinct biological communities across the North Pacific, which we refer to as 'meso-marine ecosystems' (MME). We examined the characteristics of MME over multiple years to assess temporal persistence. MME were associated with different bathymetric domains and current systems. MME differed in the overall abundance and species composition of their fauna and, therefore, almost certainly in productivity. Regular monitoring of the spatial and temporal variability of MME will enhance our ability to detect and understand coupled climate-ecosystem responses, and, in turn, help guide ecosystem-based fisheries and wildlife management.
Brief Communication: A low-cost Arduino®-based wire extensometer for earth flow monitoring
NASA Astrophysics Data System (ADS)
Guerriero, Luigi; Guerriero, Giovanni; Grelle, Gerardo; Guadagno, Francesco M.; Revellino, Paola
2017-06-01
Continuous monitoring of earth flow displacement is essential for the understanding of the dynamic of the process, its ongoing evolution and designing mitigation measures. Despite its importance, it is not always applied due to its expense and the need for integration with additional sensors to monitor factors controlling movement. To overcome these problems, we developed and tested a low-cost Arduino-based wire-rail extensometer integrating a data logger, a power system and multiple digital and analog inputs. The system is equipped with a high-precision position transducer that in the test configuration offers a measuring range of 1023 mm and an associated accuracy of ±1 mm, and integrates an operating temperature sensor that should allow potential thermal drift that typically affects this kind of systems to be identified and corrected. A field test, conducted at the Pietrafitta earth flow where additional monitoring systems had been installed, indicates a high reliability of the measurement and a high monitoring stability without visible thermal drift.
Subglacial discharges create fluctuating foraging hotspots for sea birds in tidewater glacier bays.
Urbanski, Jacek Andrzej; Stempniewicz, Lech; Węsławski, Jan Marcin; Dragańska-Deja, Katarzyna; Wochna, Agnieszka; Goc, Michał; Iliszko, Lech
2017-03-07
Although the processes occurring at the front of an ice face in tidewater glacier bays still await thorough investigation, their importance to the rapidly changing polar environment is spurring a considerable research effort. Glacier melting, sediment delivery and the formation of seabird foraging hotspots are governed by subglacial discharges of meltwater. We have combined the results of tracking black-legged kittiwakes Rissa tridactyla equipped with GPS loggers, analyses of satellite images and in situ measurements of water temperature, salinity and turbidity in order to examine the magnitude and variability of such hotspots in the context of glacier bay hydrology. Small though these hotspots are in size, foraging in them appears to be highly intensive. They come into existence only if the subglacial discharge reaches the surface, if the entrainment velocity at a conduit is high and if there is sufficient macroplankton in the entrainment layer. The position and type of subglacial discharges may fluctuate in time and space, thereby influencing glacier bay hydrology and the occurrence of foraging hotspots.
NASA Astrophysics Data System (ADS)
Waltham, Nathan J.; Sheaves, Marcus
2017-09-01
Understanding acute hyperthermic exposure risk to animals, including fish in tropical estuaries, is increasingly necessary under future climate change. To examine this hypothesis, fish (upper water column species - glassfish, Ambassis vachellii; river mullet, Chelon subviridis; diamond scale mullet, Ellochelon vaigiensis; and ponyfish, Leiognathus equulus; and lower water bottom dwelling species - whiting Sillago analis) were caught in an artificial tidal lake in tropical north Queensland (Australia), and transported to a laboratory tank to acclimate (3wks). After acclimation, fish (between 10 and 17 individuals each time) were transferred to a temperature ramping experimental tank, where a thermoline increased (2.5 °C/hr; which is the average summer water temperature increasing rate measured in the urban lakes) tank water temperature to establish threshold points where each fish species lost equilibrium (defined here as Acute Effect Temperature; AET). The coolest AET among all species was 33.1 °C (S. analis), while the highest was 39.9 °C (A. vachellii). High frequency loggers were deployed (November and March representing Austral summer) in the same urban lake where fish were sourced, to measure continuous (20min) surface (0.15 m) and bottom (0.1 m) temperature to derive thermal frequency curves to examine how often lake temperatures exceed AET thresholds. For most fish species examined, water temperature that could be lethal were exceeded at the surface, but rarely, if ever, at the bottom waters suggesting deep, cooler, water provides thermal refugia for fish. An energy-balance model was used to estimate daily mean lake water temperature with good accuracy (±1 °C; R2 = 0.91, modelled vs lake measured temperature). The model was used to predict climate change effects on lake water temperature, and the exceedance of thermal threshold change. A 2.3 °C climate warming (based on 2100 local climate prediction) raised lake water temperature by 1.3 °C. However, small as this increase might seem, it led to a doubling of time that water temperatures were in excess of AET thresholds at the surface, but also the bottom waters that presently provide thermal refugia for fish.
Abdo, David A; Bellchambers, Lynda M; Evans, Scott N
2012-01-01
Coral reefs face increasing pressures particularly when on the edge of their distributions. The Houtman Abrolhos Islands (Abrolhos) are the southernmost coral reef system in the Indian Ocean, and one of the highest latitude reefs in the world. These reefs have a unique mix of tropical and temperate marine fauna and flora and support 184 species of coral, dominated by Acropora species. A significant La Niña event during 2011 produced anomalous conditions of increased temperature along the whole Western Australian coastline, producing the first-recorded widespread bleaching of corals at the Abrolhos. We examined long term trends in the marine climate at the Abrolhos using historical sea surface temperature data (HadISST data set) from 1900-2011. In addition in situ water temperature data for the Abrolhos (from data loggers installed in 2008, across four island groups) were used to determine temperature exposure profiles. Coupled with the results of coral cover surveys conducted annually since 2007; we calculated bleaching thresholds for monitoring sites across the four Abrolhos groups. In situ temperature data revealed maximum daily water temperatures reached 29.54°C in March 2011 which is 4.2°C above mean maximum daily temperatures (2008-2010). The level of bleaching varied across sites with an average of ∼12% of corals bleached. Mortality was high, with a mean ∼50% following the 2011 bleaching event. Prior to 2011, summer temperatures reached a mean (across all monitoring sites) of 25.1°C for 2.5 days. However, in 2011 temperatures reached a mean of 28.1°C for 3.3 days. Longer term trends (1900-2011) showed mean annual sea surface temperatures increase by 0.01°C per annum. Long-term temperature data along with short-term peaks in 2011, outline the potential for corals to be exposed to more frequent bleaching risk with consequences for this high latitude coral reef system at the edge of its distribution.
Improving the Traceability of Meteorological Measurements at Automatic Weather Stations in Thailand
NASA Astrophysics Data System (ADS)
Keawprasert, T.; Sinhaneti, T.; Phuuntharo, P.; Phanakulwijit, S.; Nimsamer, A.
2017-08-01
A joint project between the National Institute of Metrology Thailand (NIMT) and the Thai Meteorology Department (TMD) was established for improving the traceability of meteorology measurements at automatic weather stations (AWSs) in Thailand. The project aimed to improve traceability of air temperature, relative humidity and atmospheric pressure by implementing on-site calibration facilities and developing of new calibration procedures. First, new portable calibration facilities for air temperature, humidity and pressure were set up as working standard of the TMD. A portable humidity calibrator was applied as a uniform and stable source for calibration of thermo-hygrometers. A dew-point hygrometer was employed as reference hygrometer and a platinum resistance thermometer (PRT) traceable to NIMT was used as reference thermometer. The uniformity and stability in both temperature and relative humidity were characterized at NIMT. A transportable pressure calibrator was used for calibration of air pressure sensor. The estimate overall uncertainty of the calibration setup is 0.2 K for air temperature, 1.0 % for relative humidity and 0.2 hPa for atmospheric pressure, respectively. Second, on-site calibration procedures were developed and four AWSs in the central part and the northern of Thailand were chosen as pilot stations for on-site calibration using the new calibration setups and developed calibration procedures. At each station, the calibration was done at the minimum temperature, average temperature and maximum temperature of the year, for air temperature, 20 %, 55 % and 90 % for relative humidity at the average air temperature of that station and at a one-year statistics pressure range for atmospheric pressure at ambient temperature. Additional in-field uncertainty contributions such as the temperature dependence on relative humidity measurement were evaluated and included in the overall uncertainty budget. Preliminary calibration results showed that using a separate PRT probe at these AWSs would be recommended for improving the accuracy of air temperature measurement. In case of relative humidity measurement, the data logger software is needed to be upgraded for achieving higher accuracy of less than 3 %. For atmospheric pressure measurement, a higher accuracy barometer traceable to NIMT could be used to reduce the calibration uncertainty to below 0.2 hPa.
DOT National Transportation Integrated Search
2017-01-01
New traffic signal controllers, which have advanced data collection abilities, offer better information about the response of traffic signal timings to traffic flows. However, traffic engineers need more than raw data. The controllers must be set up ...
29 CFR 780.203 - Performance of operations on a farm but not by the farmer.
Code of Federal Regulations, 2010 CFR
2010-07-01
... on a farm undertaken on behalf of the farmer or on behalf of the buyer of the logs or the resulting lumber by a contract logger or sawmill owner are not within the scope of agriculture unless it can be...
DOT National Transportation Integrated Search
2017-01-01
The arterial traffic signal performance measures were not used to their fullest potential in the past. The development of traffic signal controllers with event-based, high-resolution data logging capabilities enabled the advances in derivation and vi...
Improving Attachments of Non-Invasive (Type III) Electronic Data Loggers to Cetaceans
2011-09-30
Micro texturing of the suction cup to reduced leakage: Objective: Use microtexturing to create a superhydrophobic barrier between the lip and the...surface area of a solid, thereby amplifying the natural hydrophobicity of a surface. Superhydrophobicity is created by interfacial tension forces that
ERIC Educational Resources Information Center
Killam, Alice Dow
1994-01-01
A former teacher reminisces about her teaching experiences during the 1920s in a rural school along the Aroostook River in Wade, Maine. Each year, when the boat carrying the cook for loggers upriver arrived, she and her students went aboard and received a special treat of warm molasses cake. (LP)
ERIC Educational Resources Information Center
Miles, Donna
2001-01-01
In response to high numbers of preventable fatal accidents in the logging industry, the Occupational Safety and Health Administration (OSHA) developed a week-long logger safety training program that includes hands-on learning of safety techniques in the woods. Reaching small operators has been challenging; outreach initiatives in Maine, North…
USDA-ARS?s Scientific Manuscript database
Micrometeorological methods and ecosystem-scale energy and mass flux density measurements have become increasingly important in soil, agricultural, and environmental sciences. For many scientists without formal training in atmospheric science, these techniques are relatively inaccessible. Eddy cov...
Wireless sensor network for irrigation application in cotton
USDA-ARS?s Scientific Manuscript database
A wireless sensor network was deployed in a cotton field to monitor soil water status for irrigation. The network included two systems, a Decagon system and a microcontroller-based system. The Decagon system consists of soil volumetric water-content sensors, wireless data loggers, and a central data...
NASA Astrophysics Data System (ADS)
Kawai, J.; Miyamoto, M.; Kawabata, M.; Nosé, M.; Haruta, Y.; Uehara, G.
2017-08-01
We characterized a low temperature superconducting quantum interference device (SQUID) magnetometer system developed for high-sensitivity geomagnetic field measurement, and demonstrated the detection of weak geomagnetic signals. The SQUID magnetometer system is comprised of three-axis SQUID magnetometers housed in a glass fiber reinforced plastic cryostat, readout electronics with flux locked loop (FLL), a 24-bit data logger with a global positioning system and batteries. The system noise was approximately 0.2 pT √Hz- 1/2 in the 1-50 Hz frequency range. This performance was determined by including the thermal noise and the shielding effect of the copper shield, which covered the SQUID magnetometers to eliminate high-frequency interference. The temperature drift of the system was ˜0.8 pT °C- 1 in an FLL operation. The system operated for a month using 33 l liquid helium. Using this system, we performed the measurements of geomagnetic field in the open-air, far away from the city. The system could detect weak geomagnetic signals such as the Schumann resonance with sixth harmonics, and the ionospheric Alfvén resonance appearing at night, for the north-south and east-west components of the geomagnetic field. We confirm that the system was capable of high-sensitivity measurement of the weak geomagnetic activities.
Ghirlando, Rodolfo; Balbo, Andrea; Piszczek, Grzegorz; Brown, Patrick H.; Lewis, Marc S.; Brautigam, Chad A.; Schuck, Peter; Zhao, Huaying
2013-01-01
Sedimentation velocity (SV) is a method based on first-principles that provides a precise hydrodynamic characterization of macromolecules in solution. Due to recent improvements in data analysis, the accuracy of experimental SV data emerges as a limiting factor in its interpretation. Our goal was to unravel the sources of experimental error and develop improved calibration procedures. We implemented the use of a Thermochron iButton® temperature logger to directly measure the temperature of a spinning rotor, and detected deviations that can translate into an error of as much as 10% in the sedimentation coefficient. We further designed a precision mask with equidistant markers to correct for instrumental errors in the radial calibration, which were observed to span a range of 8.6%. The need for an independent time calibration emerged with use of the current data acquisition software (Zhao et al., doi 10.1016/j.ab.2013.02.011) and we now show that smaller but significant time errors of up to 2% also occur with earlier versions. After application of these calibration corrections, the sedimentation coefficients obtained from eleven instruments displayed a significantly reduced standard deviation of ∼ 0.7 %. This study demonstrates the need for external calibration procedures and regular control experiments with a sedimentation coefficient standard. PMID:23711724
[Validation of cold chain during distribution of parenteral nutrition].
Tuan, Federico; Perone, Virginia; Verdini, Rocio; Pell, Maria Betina; Traverso, Maria Luz
2015-09-01
this study aims to demonstrate the suitability of the process used to condition the extemporaneous mixtures of parenteral nutrition for distribution, considering the objective of preserving the cold chain during transport until it reaches the patient, necessary to ensure stability, effectiveness and safety of these mixtures. concurrent validation, design and implementation of a protocol for evaluating the process of packaging and distribution of MNPE developed by a pharmaceutical laboratory. Running tests, according to predefined acceptance criteria. It is performed twice, in summer and on routes that require longer transfer time. Evaluation of conservation of temperature by monitoring the internal temperature values of each type of packaging, recorded by data loggers calibrated equipment. the different tests meet the established criteria. The collected data ensure the maintenance of the cold chain for longer than the transfer time to the most distant points. this study establishes the suitability of the processes to maintaining the cold chain for transfer from the laboratory to the patient pharmacist. Whereas the breaking of cold chain can cause changes of compatibility and stability of parenteral nutrition and failures nutritional support, this study contributes to patient safety, one of the relevant dimensions of quality of care the health. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Local- and landscape-scale land cover affects microclimate and water use in urban gardens.
Lin, Brenda B; Egerer, Monika H; Liere, Heidi; Jha, Shalene; Bichier, Peter; Philpott, Stacy M
2018-01-01
Urban gardens in Central California are highly vulnerable to the effects of climate change, experiencing both extended high heat periods as well as water restrictions because of severe drought conditions. This puts these critical community-based food production systems at risk as California is expected to experience increasing weather extremes. In agricultural systems, increased vegetation complexity, such as greater structure or biodiversity, can increase the resilience of food production systems from climate fluctuations. We test this theory in 15 urban gardens across California's Central Coast. Local- and landscape-scale measures of ground, vegetation, and land cover were collected in and around each garden, while climate loggers recorded temperatures in each garden in 30min increments. Multivariate analyses, using county as a random factor, show that both local- and landscape-scale factors were important. All factors were significant predictors of mean temperature. Tallest vegetation, tree/shrub species richness, grass cover, mulch cover, and landscape level agricultural cover were cooling factors; in contrast, garden size, garden age, rock cover, herbaceous species richness, and landscape level urban cover were warming factors. Results were similar for the maximum temperature analysis except that agriculture land cover and herbaceous species richness were not significant predictors of maximum temperature. Analysis of gardener watering behavior to observed temperatures shows that garden microclimate was significantly related to the number of minutes watered as well as the number of liters of water used per watering event. Thus gardeners seem to respond to garden microclimate in their watering behavior even though this behavior is most probably motivated by a range of other factors such as water regulations and time availability. This research shows that local management of ground cover and vegetation can reduce mean and maximum temperatures in gardens, and the reduced temperatures may influence watering behavior of gardeners. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
In Search for Diffuse Hydrothermal Venting at North Pond, Western Flank of the Mid-Atlantic-Ridge
NASA Astrophysics Data System (ADS)
Villinger, H. W.; Becker, K.; Hulme, S.; Kaul, N. E.; Müller, P.; Wheat, C. G.
2015-12-01
We present results from temperature measurements made with a ROV temperature lance in sediments deposited on the slopes of abyssal hills and small basins surrounding North Pond. North Pond is a ~8x15 km large sediment basin located on ~7 Ma year old crust west of the Mid-Atlantic Ridge at 23°N. Data were collected with the ROV Jason II during cruise MSM37 on the German RV Maria S. Merian in April 2014. The temperature lance consists of a 60 cm long stainless steel tube (o.d. 12 mm) housing 8 thermistors with a spacing of 80 mm, resulting in an active length of 56 cm. Data are logged with an 8-channel data logger (XR-420-T8, RBR, Ottawa) and transmitted online to the control van of the ROV. Data reduction and temperature gradient calculation is done according to the HFRED algorithm (Villinger & Davis, 1987). 90 sites in total were visited, 88 gave good data for temperature gradient calculation. Calculated gradients are usually of good to very good quality. The gradients vary between less than 20 to more than 1000 mK/m reflecting the very heterogeneous distribution of geothermal heat flow. The expected conductive lithospheric heat flow for North Pond is ~190 mW/m2 (geothermal gradient of ~190 mK/m with a thermal conductivity of 1 W/Km). The highest temperature gradients are measured in places where temperature ~50 cm below the sediment-water boundary exceeds bottom water temperature by ~0.5 K . These high temperature gradients may reflect local hydrothermal circulation within the pillow lavas, however no focused discharge was detected. The analysis of temperature measurements made with the ROV-mounted CTD shows clearly detectable bottom water temperature anomalies. We infer that they are either caused by hydrothermal discharge through the thin sediment cover or through unsedimented pillow basalts nearby. Hydrothermal circulation in a North-Pond-like environment appears to be diffuse in nature, hence very difficult if not impossible to detect and to quantify.
Remote sensing as a tool to analyse lizards behaviour
NASA Astrophysics Data System (ADS)
Dos Santos, Remi; Teodoro, Ana C.; Carretero, Miguel; Sillero, Neftalí
2016-10-01
Although the spatial context is expected to be a major influence in the interactions among organisms and their environment, it is commonly ignored in ecological studies. This study is part of an investigation on home ranges and their influence in the escape behaviour of Iberian lizards. Fieldwork was conducted inside a 400 m2 mesocosm, using three acclimatized adult male individuals. In order to perform analyses at this local scale, tools with high spatial accuracy are needed. A total of 3016 GPS points were recorded and processed into a Digital Elevation Model (DEM), with a pixel resolution of 2 cm. Then, 1156 aerial photos were taken and processed to create an orthophoto. A refuge map, containing possible locations for retreats was generated with supervised image classification algorithms, obtaining four classes (refuges, vegetation, bare soil and organic soil). Furthermore, 50 data-loggers were randomly placed, recording evenly through the area temperature and humidity every 15'. After a month of recording, all environmental variables were interpolated using Kriging. The study area presented an irregular elevation. The humidity varied according to the topography and the temperature presented a West-East pattern. Both variables are of paramount importance for lizard activity and performance. In a predation risk scenario, a lizard located in a temperature close to its thermal optimum will be able to escape more efficiently. Integration of such ecologically relevant elements in a spatial context exemplifies how remote sensing tools can contribute to improve inference in behavioural ecology.
Ecohydrology of a Sphagnum peatland in transitional climate - an interdysciplinary study
NASA Astrophysics Data System (ADS)
Słowińska, S.; Słowiński, M.; Lamentowicz, M.; Skrzypek, G.
2012-04-01
Sphagnum peatlands of the Central Europe are regarded as the valuable and endangered habitats. Their existence depends on the complex climatic, hydrological, topographical and botanical conditions. Good understanding of peatlands' ecohydrology is crucial for the appropriate environmental management. Our long-term ecological study is focused on a poor fen located in Northern Poland - a unique floristic nature reserve and Nature 2000 area. Main aims of the research were to: a) understand an influence of the temperature and precipitation on the ground water, b) explain an impact of the local climate and the groundwater table level on testate amoebae communities, Sphagnum mosses growth and stable carbon, nitrogen and oxygen isotope compositions, c) use the neo- ecological data for the quantitative palaeoecological reconstructions. We have been conducting the monitoring of the growth of Sphagnum mosses in five plots. Vegetation was sampled three times during the growing season for the stable isotope and testate amoebae analyses (July, September and December 2009). Temperature of the air and acrotelm, air humidity, precipitation and groundwater table were recorded using automatic data loggers. Our research confirmed that even small fluctuation of temperature, precipitation and annual distribution of precipitation have a very strong impact on the hydrology of the peatland. Testate amoeba communities and stable isotopes from Sphagnum clearly indicated the hydrological response of the mire in the different parts of the peatland. The next step is a detailed seasonal study supported by the manipulative warming experiment.
NASA Astrophysics Data System (ADS)
Jin, Rui; kang, Jian
2017-04-01
Wireless Sensor Networks are recognized as one of most important near-surface components of GEOSS (Global Earth Observation System of Systems), with flourish development of low-cost, robust and integrated data loggers and sensors. A nested eco-hydrological wireless sensor network (EHWSN) was installed in the up- and middle-reaches of the Heihe River Basin, operated to obtain multi-scale observation of soil moisture, soil temperature and land surface temperature from 2012 till now. The spatial distribution of EHWSN was optimally designed based on the geo-statistical theory, with the aim to capture the spatial variations and temporal dynamics of soil moisture and soil temperature, and to produce ground truth at grid scale for validating the related remote sensing products and model simulation in the heterogeneous land surface. In terms of upscaling research, we have developed a set of method to aggregate multi-point WSN observations to grid scale ( 1km), including regression kriging estimation to utilize multi-resource remote sensing auxiliary information, block kriging with homogeneous measurement errors, and bayesian-based upscaling algorithm that utilizes MODIS-derived apparent thermal inertia. All the EHWSN observation are organized as datasets to be freely published at http://westdc.westgis.ac.cn/hiwater. EHWSN integrates distributed observation nodes to achieve an automated, intelligent and remote-controllable network that provides superior integrated, standardized and automated observation capabilities for hydrological and ecological processes research at the basin scale.
To better characterize the relationships between both adjacent hydrology/ precipitation and nutrient processing with groundwater level fluctuations, continuous water level data are being collected across three dominant wetland types, each with varied landscape characteristics. Th...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
Modeling and Simulation Network Data Standards
2011-09-30
COMBATXXI Movement Logger Data Output Dictionary. Field # Geocentric Coordinates (GCC) Heading Geodetic Coordinates (GDC) Heading Universal...B-8 Field # Geocentric Coordinates (GCC) Heading Geodetic Coordinates (GDC) Heading Universal Transverse Mercator (UTM) Heading...FKSM Fort Knox Supplemental Material FM field manual GCC geocentric coordinates GDC geodetic coordinates GIG global information grid
Signal processing techniques were applied to high-resolution time series data obtained from conductivity loggers placed upstream and downstream of a wastewater treatment facility along a river. Data was collected over 14-60 days, and several seasons. The power spectral densit...
Pressure-Height Properties of Water with Automated Data Collection
ERIC Educational Resources Information Center
Bates, Alan
2013-01-01
Instrumentation available for teachers and students has changed considerably during the last 20 years. The data logger-sensor system has the advantage of taking reliable measurements over time with suitable sample rates. This experiment is not an open-ended investigation but an opportunity to explore the established relationship between the…
Forestry BMP Implementation Costs for Virginia
R.M. Shaffer; H.L. Haney; E.G. Worrell; W.M. Aust
1998-01-01
Forestry Best Management Practices (BMPs) are operational techniques used to protect water quality during timber harvesting operations. The implementation cost of BMPs is important to loggers, forest landowners, and the forest industry. This study provides an estimate of BMP implementation cost on a per harvested acre basis for the coastal plain, Piedmont, and...
RELATIONSHIPS BETWEEN HABITAT ARRANGEMENT AND JUVENILE WINTER FLOUNDER DENSITY IN NARRAGANSETT BAY
We used aerial photography in conjunction with a 1-m beam trawl attached to a videocamera with GPS overwrite and a YSI water quality logger to quantify fish densities and characterize habitats in Narragansett Bay and in Rhode Island's coastal lagoons. We compared fish counts fro...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
Improving Attachments of Non-Invasive (Type III) Electronic Data Loggers to Cetaceans
2014-09-30
the assessment tag impact on animal health and well-being. Specifically, we are working to develop methods that will enable the accurate estimates...currently not available for any marine mammal, about animal health and activity has the potential to revolutionize how animals are cared for in these
Maya Traditional Knowledge: Preserving Forests in Guatemala.
ERIC Educational Resources Information Center
Bernstein, Jacob
1996-01-01
In the mountains of western Guatemala, Maya K'iche communities draw on extensive indigenous knowledge of the local ecosystem to manage sections of forest allocated as community responsibility for generations. Supported by spiritual beliefs, community elders seek to guide the use and preservation of the forest despite illegal loggers, corrupt…
Cost of wetland protection using a Christy cable yarder
Chris B. LeDoux; John E. Baumgras; Edwin S. Miyata
1990-01-01
Forest managers, loggers, land-use planners, and other decision makers need an understanding of estimating the cost of protecting wetlands using cable logging systems to harvest timber products. Results suggest that protection costs can range from $245 to $490 per acre depending on the degree of protection desired.
Dennis P. Bradley; Frank E. Biltonen
1973-01-01
Describes the productivity of selected aspen pulpwood loggers in northern Minnesota. The most important factors affecting productivity were the ratio of harvested trees per acre to total trees per acre, harvested volume per acre, and the spacing of nonharvested trees
Primary forest products industry and industrial roundwood production, Michigan, 1969.
James E. Blyth; Allen H. Boelter
1971-01-01
Michigan loggers cut 173.8 million cubic feet of industrial roundwood products in 1969. Ninety percent was pulpwood and saw logs. Production is shifting from softwoods to hardwoods. The number of active primary wood-using mills declined rapidly from 1954 to 1969, but production per mill has expanded.
Cost of wetland protection using cable logging systems
Chris B. LeDoux; John E. Baumgras
1990-01-01
Forest managers, loggers, land-use planners, and other decision makers need an understanding of estimating the cost of protecting wetlands using cable logging systems to harvest timber products. Results suggest that protection costs can range from $244.75 to $489.50 per acre depending on the degree of protection desired.
40 CFR 49.4165 - Control equipment requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., except for § 60.18(c)(2) and (f)(2) for those utility flares operated with an electronically controlled...) Equipped with one of the following: (A) A continuous burning pilot flame. (B) An electronically controlled... electronically controlled automatic igniter, such as a chart recorder, data logger or similar devices; (vi...
40 CFR 49.4165 - Control equipment requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., except for § 60.18(c)(2) and (f)(2) for those utility flares operated with an electronically controlled...) Equipped with one of the following: (A) A continuous burning pilot flame. (B) An electronically controlled... electronically controlled automatic igniter, such as a chart recorder, data logger or similar devices; (vi...
Wireless sensor network for monitoring soil moisture and weather conditions
USDA-ARS?s Scientific Manuscript database
A wireless sensor network (WSN) was developed and deployed in three fields to monitor soil water status and collect weather data for irrigation scheduling. The WSN consists of soil-water sensors, weather sensors, wireless data loggers, and a wireless modem. Soil-water sensors were installed at three...
Body temperature and respiratory dynamics in un-shaded beef cattle.
Gaughan, J B; Mader, T L
2014-09-01
In this study body temperature (BT, °C) and panting score (PS, 0-4.5; where 0 = no panting/no stress and 4.5 = catastrophic stress) data were obtained from 30 Angus steers housed outside over 120 days Steers were implanted with a BT transmitter on day -31, BT was recorded at 30-min intervals to a data logger and downloaded each day to a database. The cattle were housed in ten outdoor un-shaded pens with an earthen floor, eight of which had a pen floor area of 144 m2 (three transmitter steers plus five non-transmitter steers; 18 m2/steer) and two had an area of 168 m2 (three transmitter steers and six non-transmitter steers; 18.7 m2/steer). Only data from the transmitter steers were used in this study. The PS of the steers was obtained daily (± 15 min) at 0600 hours (AM), 1200 hours (MD) and 1600 hours (PM). At the same times climate variables (ambient temperature, black globe temperature, solar radiation, relative humidity, wind speed and rainfall) were obtained from an on-site weather station. PS observations were made from outside the pens so as not to influence cattle responses. The two closest BT values to the time when PS was obtained were downloaded retrospectively from a logger and averaged. A total of 8,352 observations were used to generate second order polynomial response curves: (AM) y = 39.08 + 0.009 x + 0.137x2 (R2 = 0.94; P < 0.001) (MD) y = 39.09 + 0.914x − 0.080x2 (R2 = 0.89; P < 0.001) and (PM) y = 39.52 + 0.790x − 0.068x2 (R2 = 0.83; P < 0.001) where y = BT (°C) and x PS. These data suggest that PS is a good indicator of body temperature. The BT at MD corresponded to slightly lower PS compared with PM, e.g., for PS 1; BT at MD = 39.1 ± 0.05 °C whereas BT at PM = 39.5 ± 0.05 °C. However during AM, BT was lower (P < 0.05) at PS 1, 2 and 2.5 compared with MD and PM. For example, when PS was 2.5 the BT at AM was 40.2 ± 0.04 °C, at MD it was 40.9 ± 0.04 °C and at PM BT was 41.1 ± 0.04 °C. When PS was 0 the BT at AM and MD were similar. The AM response curve suggests animals attempt to increase heat dissipation during the cooler AM period relative to MD and PM. Morning observation of cattle (before feeding) are crucial for effective heat load management especially on days when high heat load is expected. The MD and PM observations provide a good indication of the impact of high environmental heat load on cattle. Differences in PS between AM and PM observations suggest that more research is needed to determine the effect of night time conditions on BT, PS and overall respiratory dynamics of cattle during periods of hot weather.
Identifying the dominant thermal controls in a small salmonid-bearing creek with DTS and LDCA
NASA Astrophysics Data System (ADS)
Hatch, C. E.; Boughton, D. A.; Mora, E.
2012-12-01
Temperature has long been used as an indicator of ecosystem health and suitability for aquatic species, particularly in sensitive areas crucial to the persistence of declining fish populations. In addition, the EPA may soon implement TMDLs for stream temperatures throughout the U.S. Typically, stream temperature surveys have long duration but only at point locations, limiting the precision of efforts to predict stream temperatures or understand broader climate linkages. Specifically, single temperature loggers give no insight into the spatial heterogeneity of thermal conditions often exploited by biota. Distributed Temperature Sensing (DTS) provides temperature data at high spatial and temporal resolution up to 5-km in length, allowing for detailed assessment of a creek's heat budget. Rather than calculating a detailed energy balance from a single site or using a statistical approach, here we describe a hybrid method that uses Least Dependent Component Analysis (LDCA) capable of taking advantage of DTS data density in time and space. The method identifies distinct thermal components in the stream's heat budget, using only temperature data and an algorithm based on mutual information that "unmixes" signals in the temperature data. These signals can be interpreted as sets of heat-flux elements sharing coordinated (non-independent) dynamics, both simplifying the number of heat budget components as well as the number thermally forcing stream temperatures. Comparing these components to meteorological data and fluvial system structure allowed us to relate the groups back to causal heating and cooling mechanisms, which can be tested directly with targeted heat-budget studies. We applied this method to a small, arid-land creek, and found that a minimum of three distinct components were necessary to describe the thermal heterogeneity of a 1-km reach. We could also estimate a spatial response profile of each component, yielding insight into possible links between stream geomorphology and function. This method shows promise to aid with siting and defining detailed heat-budget studies, determining the dimensionality of heat budgets in natural streams, and more broadly for associating thermal components to fluvial structure and processes.
NASA Astrophysics Data System (ADS)
Masaki, Y.; Nozaki, T.; Saruhashi, T.; Kyo, M.; Sakurai, N.; Yokoyama, T.; Akiyama, K.; Watanabe, M.; Kumagai, H.; Maeda, L.; Kinoshita, M.
2017-12-01
The middle Okinawa Trough, located along the Ryukyu- arc on the margin of the East China Sea, has several active hydrothermal fields. From February to March 2016, Cruise CK16-01 by D/V Chikyu targeted the Iheya-North Knoll and southern flank of the Iheya Minor Ridge to comprehend sub-seafloor geological structure and polymetallic sulfide mineralization. In this cruise, we installed two Kuroko cultivation apparatuses equipped with P/T sensors, flowmeter and load cell to monitor pressure, temperature and flow rate of hydrothermal fluid discharged from the artificial hydrothermal vent together with weight of hydrothermal precipitate. During Cruise KR16-17 in January 2017, two cultivation cells with sensor loggers were successfully recovered by ROV Kaiko MK-IV and R/V Kairei. We report these physical sensor data obtained by more than 10 months monitoring at two deep-sea artificial hydrothermal vents through many first and challenging operations.Hole C9017B at southern flank of the Iheya Minor Ridge (water depth of 1,500 mbsl), fluid temperature was constant ca. 75 ºC for 5 months from the beginning of monitoring. Then temperature gradually decrease to be 40 ºC. In November 2016, temperature and pressure suddenly dropped and quickly recovered due to the disturbance of subseafloor hydrology, induced by another drilling operation at Hole C9017A which is 10.8 meters northeastward from Hole C9017B during Cruise CK16-05. Temperature data exhibit conspicuous periodic 12.4hour cycles and this is attributable to oceanic tidal response. The amplitude of temperature variations increased along with decline of the temperature variations increased along with decline of the temperature. The average flow rate was 67 L/min for 9 hours from the onset of monitoring.Hole C9024A at the Iheya-North Knoll (water depth of 1,050 msl), the maximum temperature reached 308 ºC, which is similar to the maximum value of 311 ºC obtained from the ROV thermometer. The average flow rate was 289 L/min for 8 days from onset of monitoring.
De Jong, Grant D; Hoback, W Wyatt; Higley, Leon G
2011-01-01
Often carrion decomposition studies are conducted using a single carcass or a few carcasses sampled repeatedly through time to reveal trends in succession community composition. Measurements of biomass and other abiotic parameters (e.g., temperature) are often collected on the same carcasses but are rarely a focal point of the studies. This study investigated the effects that repeated sampling during experiments have on the decomposition of carrion, measured as both gross biomass (carcass plus fauna) and net biomass (carcass only), on carcasses disturbed on every visit (with weighing only or also with the collection of fauna) and on carcasses disturbed only once. Each trial lasted at least 21 days, with samples taken in triplicate. Rat carcasses used in this study were placed in the field on the same day and either weighed on every visit or ignored until a given day. Internal and ambient air temperatures were recorded on each carcass at the time of sampling and on undisturbed carcasses using temperature loggers. The presence of succession fauna did not result in significant biomass loss on most days; however, there were individual days early in decomposition (days 3 through 6) when the succession fauna comprised a large portion of the gross biomass. With the exception of biomass loss by the emigration of maggots on days 4 and 5, neither repeated weighing of the carcasses nor repeated weighing and faunal sampling of the carcasses statistically affected the rate of biomass loss. Internal temperatures of carcasses sampled repeatedly were frequently 2-5°C lower than those that had not been disturbed, and ambient temperatures differed significantly depending on the location of measurement device. Results indicate that methods used historically for biomass loss determination in experimental forensic entomology studies are adequate, but further refinements to experimental methodology are desirable. © 2010 American Academy of Forensic Sciences.
Bimodal Distribution of Geyser Preplay Eruptions: Lone Star Geyser, Yellowstone National Park
NASA Astrophysics Data System (ADS)
Namiki, A.; Hurwitz, S.; Murphy, F.; Manga, M.
2014-12-01
Geyser eruption intervals are determined by rates of water and heat discharge into shallow subsurface reservoirs and the conduit. In some geysers, small amounts of water discharge prior to a main eruption ('Preplay') can affect eruption intervals. Water discharge during preplay reduces the hydrostatic pressure, which in turn, induces boiling of water that is at, or near the critical temperature. Ascending steam slugs from depth can also lead to shorter eruption intervals (Namiki et al., 2014). In April 2014, we carried a five day experiment at Lone Star Geyser, Yellowstone National Park. Eruptions and their preplays were recorded with an infrared sensor that measured temperature variations immediately above the geyser cone (3.4~m high), temperature loggers that measured water temperature at the base of the cone and in the outflow channels, and visual observations. At Lone Star Geyser, during the preplay phase of the eruption, mainly liquid water is erupted, whereas the main phase of the eruption begins with the liquid-water dominated eruption and turns into the steam discharge. The temperature rise in an outflow channel indicates the occurrence of preplays and initiation of the main eruption. The acquired data suggests that the preplay patterns of Lone Star Geyser are vigorous and complex, consistent with previous observations (Karlstrom et al., 2013). Our new observations reveal two typical styles: 1) vigorous preplays with few events (<5) and long intervals (>20~minutes) that last approximately 40~minutes, and 2) less vigorous preplays that include several events (>5) with short intervals (few minutes), and continue approximately for one hour. Probability distributions of preplay durations show two peaks indicating the bimodal activity. The bimodality of Lone Star preplays may be a result of subtle change of temperature distribution in a convecting reservoir which has been observed in laboratory experiments (Toramaru and Maeda, 2013).
The Inverse-Square Law with Data Loggers
ERIC Educational Resources Information Center
Bates, Alan
2013-01-01
The inverse-square law for the intensity of light received at a distance from a light source has been verified using various experimental techniques. Typical measurements involve a manual variation of the distance between a light source and a light sensor, usually by sliding the sensor or source along a bench, measuring the source-sensor distance…
Educational Electrical Appliance Power Meter and Logger
ERIC Educational Resources Information Center
Nunn, John
2013-01-01
The principles behind two different designs of inductive power meter are presented. They both make use of the microphone input of a computer which, together with a custom-written program, can record the instantaneous power of a domestic electrical appliance. The device can be built quickly and can be calibrated with reference to a known power…
Logging roads and log decks for wildlife habitat
William H. Healy
1989-01-01
Roads are essential to manage and use forest land. They can improve wildlife habitat and provide recreational opportunities. But roads are often controversial because they have so many different users-loggers, hikers, hunters, and off-road-vehicle drivers. Benefits to wildlife can be maximized and user conflicts minimized by careful planning and design. Decisions about...
Physiological and psychological impacts of extended work hours in logging operations
Dana Mitchell; Tom Gallagher
2007-01-01
A study was initiated in 2006 to develop an understanding of the considerations of using extended work hours in the logging industry in the southeastern United States. Through semistructured interviews, it was obvious that loggers were individually creating ways of successfully implementing extended working hours without understanding the impacts that extended working...
Skateboard/Longboard Speedometer Project
ERIC Educational Resources Information Center
Hare, Jonathan
2012-01-01
A simple, low-cost infrared LED speedometer is described that can be fitted to a skateboard, longboard or even a bicycle to measure speed. Notes on building, setting up and calibration are given. When used with a low-cost data logger, continuous measurements of speed can be made while out and about. The device forms an interesting science club…
Signal processing techniques were applied to high-resolution time series data obtained from conductivity loggers placed upstream and downstream of an oil and gas wastewater treatment facility along a river. Data was collected over 14-60 days. The power spectral density was us...
Conditioned Pupil Disposition, Autonomy, and Effective Use of ICT in Science Classrooms.
ERIC Educational Resources Information Center
Rodrigues, Susan
2003-01-01
Data from three projects (a CD-ROM of the periodic table, video animation on CD ROM, and data loggers) show how conditioned dispositions affect information/communications technology use. The projects demonstrate how students have been conditioned to work mindlessly in science classrooms, following the path of least cognitive demand and avoiding…
Using a Digital Video Camera to Study Motion
ERIC Educational Resources Information Center
Abisdris, Gil; Phaneuf, Alain
2007-01-01
To illustrate how a digital video camera can be used to analyze various types of motion, this simple activity analyzes the motion and measures the acceleration due to gravity of a basketball in free fall. Although many excellent commercially available data loggers and software can accomplish this task, this activity requires almost no financial…
Chris B. LeDoux
2006-01-01
Forest landowners, managers, loggers, land-use planners, and other decision/policy makers need to understand the opportunity cost associated with different levels of allowable management and required/voluntary protection in streamside management zones (SMZs). Four different logging technologies, two mature hardwood stands, three levels of streamside zone protection,...
Use of expert systems for integrated silvicultural planning
Chris B. LeDoux
1997-01-01
The use of silvicultural treatments in hardwood stands presents opportunities for increasing the growth and yield of quality sawtimber and enhancing the suitability of the site for use by numerous species of wildlife. Planners, loggers, and managers must consider multiple aspects of the ecosystem when making silvicultural decisions. In this paper we demonstrate an...
Coupled Oscillators: Interesting Experiments for High School Students
ERIC Educational Resources Information Center
Kodejška, C.; Lepil, O.; Sedlácková, H.
2018-01-01
This work deals with the experimental demonstration of coupled oscillators using simple tools in the form of mechanical coupled pendulums, magnetically coupled elastic strings or electromagnetic oscillators. For the evaluation of results the data logger Lab Quest Vernier and video analysis in the Tracker program were used. In the first part of…
ERIC Educational Resources Information Center
Bates, Alan
2015-01-01
Instruments or digital meters with data values visible on a seven-segment display can easily be found in the physics lab. Examples include multimeters, sound level meters, Geiger-Müller counters and electromagnetic field meters, where the display is used to show numerical data. Such instruments, without the ability to connect to computers or data…
Improving Attachments of Non-Invasive (Type III) Electronic Data Loggers to Cetaceans
2013-09-30
logged using a netbook and USB analog to digital converter. Initial testing of the SSSCup was conducted on a common dolphin (Delphinus delphis) cadaver...cell and five pressure sensors (four to measure internal cup pressure and one for atmospheric pressure). Sensor data are logged using a netbook and
Solving wood chip transport problems with computer simulation.
Dennis P. Bradley; Sharon A. Winsauer
1976-01-01
Efficient chip transport operations are difficult to achieve due to frequent and often unpredictable changes in distance to market, chipping rate, time spent at the mill, and equipment costs. This paper describes a computer simulation model that allows a logger to design an efficient transport system in response to these changing factors.
Implementation guide for turbidity threshold sampling: principles, procedures, and analysis
Jack Lewis; Rand Eads
2009-01-01
Turbidity Threshold Sampling uses real-time turbidity and river stage information to automatically collect water quality samples for estimating suspended sediment loads. The system uses a programmable data logger in conjunction with a stage measurement device, a turbidity sensor, and a pumping sampler. Specialized software enables the user to control the sampling...
Hardwood log supply: a broader perspective
Iris Montague; Adri Andersch; Jan Wiedenbeck; Urs Buehlmann
2015-01-01
At regional and state meetings we talk with others in our business about the problems we face: log exports, log quality, log markets, logger shortages, cash flow problems, the weather. These are familiar talking points and real and persistent problems. But what is the relative importance of these problems for log procurement in different regions of...
Technoeconomic analysis of conventional logging systems operating from stump to landing
Raymond L. Sarles; William G. Luppold; William G. Luppold
1986-01-01
Analyzes technical and economic factors for six conventional logging systems suitable for operation in eastern forests. Discusses financial risks and business implications for loggers investing in high-production, state-of-the-art logging systems. Provides logging contractors with information useful as a preliminary guide for selection of equipment and systems....
Changes in the Logging Labor Force
Charles H. Wolf; Jean W. Nolley
1977-01-01
Employment in the logging industry dropped 28 percent between 1950 and 1970, while output of industrial roundwood increased 31 percent. Today's loggers are older, better educated, and more skilled. A large proportion are self-employed, many work less than a full year, and a substantial number have incomes below the poverty level. Mechanization of timber harvesting...