Brain Perfusion and Arterial Blood Flow Velocity During Prolonged Body Tilting.
Montero, David; Rauber, Sven
2016-08-01
It remains unknown whether brain perfusion is preserved and mirrored by middle cerebral blood flow velocity (MCA BFV) during prolonged changes in body posture. Herein, we examined the impact of sustained (180 min) 30° head-up (HUT) and head-down (HDT) tilt on brain perfusion, as determined by MCA BFV and blood flow in the extracranial arteries. In 10 healthy male subjects, arterial diameters, BFVs, and blood flows were determined in the left internal carotid (ICA) and vertebral (VA) arteries using duplex Doppler ultrasound in supine rest, and 5, 20, 60, 120, and 180 min following 30° HUT and HDT. MCA BFV was recorded throughout with transcranial Doppler ultrasound. ICA as well as VA diameters and blood flows were unaltered during HUT. Likewise, brain blood flow and MCA BFV were preserved with HUT. In the HDT protocol, ICA and VA diameters were gradually increased, although ICA, VA, and brain blood flows were preserved. MCA BFV was progressively reduced during HDT. In addition, MCA BFV was positively associated with ICA BFV (β = 0.9) and negatively associated with ICA diameter (β = -125.5). MCA BFV was positively associated with brain blood flow during HUT (β = 0.2) but not HDT. Brain perfusion is preserved whereas MCA BFV is progressively decreased and associated with extracranial arterial BFV during sustained 30° HDT. Therefore, MCA BFV may not be a surrogate of brain perfusion in conditions including prolonged HDT. Montero D, Rauber S. Brain perfusion and arterial blood flow velocity during prolonged body tilting. Aerosp Med Hum Perform. 2016; 87(8):682-687.
Arkuszewski, M; Krejza, J; Chen, R; Kwiatkowski, J L; Ichord, R; Zimmerman, R; Ohene-Frempong, K; Desiderio, L; Melhem, E R
2011-09-01
TCD screening is widely used to identify children with SCD at high risk of stroke. Those with high mean flow velocities in major brain arteries have increased risk of stroke. Thus, our aim was to establish reference values of interhemispheric differences and ratios of blood flow Doppler parameters in the tICA, MCA, and ACA as determined by conventional TCD in children with sickle cell anemia. Reference limits of blood flow parameters were established on the basis of a consecutive cohort of 56 children (mean age, 100 ± 40 months; range, 29-180 months; 30 females) free of neurologic deficits and intracranial stenosis detectable by MRA, with blood flow velocities <170 cm/s by conventional TCD. Reference limits were estimated by using tolerance intervals, within which are included with a probability of .90 of all possible data values from 95% of a population. Average peak systolic velocities were significantly higher in the right hemisphere in the MCA and ACA (185 ± 28 cm/s versus 179 ± 27 and 152 ± 30 cm/s versus 143 ± 34 cm/s respectively). Reference limits for left-to-right differences in the mean flow velocities were the following: -43 to 33 cm/s for the MCA; -49 to 38 cm/s for the ACA, and -38 to 34 cm/s for the tICA, respectively. Respective reference limits for left-to-right velocity ratios were the following: 0.72 to 1.25 cm/s for the MCA; 0.62 to 1.39 cm/s for the ACA, and 0.69 to 1.27 cm/s for the tICA. Flow velocities in major arteries were inversely related to age and Hct or Hgb. The study provides reference intervals of TCD flow velocities and their interhemispheric differences and ratios that may be helpful in identification of intracranial arterial stenosis in children with SCD undergoing sonographic screening for stroke prevention.
Ultrasonic Doppler measurement of renal artery blood flow
NASA Technical Reports Server (NTRS)
Freund, W. R.; Beaver, W. L.; Meindl, J. D.
1976-01-01
Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.
Li, Le; Ke, Zheng; Tong, Kai Yu; Ying, Michael
2010-04-01
Ischemic stroke is typically characterized by the disruption of cerebral blood flow. This study aimed to consecutively evaluate the cerebral blood flow changes in a focal ischemia rat model during the occlusion-reperfusion procedure and along the recovery stage after stroke. In 12 Sprague Dawley (SD) rats, a middle cerebral artery occlusion/reperfusion (MCAo/r) surgery was conducted, which combines a permanent occlusion of the right common carotid artery (CCA), external carotid artery (ECA) and a transient occlusion of the right internal carotid artery (ICA) and middle cerebral artery (MCA) with a monofilament introduced from the proximal ICA towards the distal right ICA then removed after 90 min. Blood flow velocity (BFV) from the concerned arteries were measured using ultrasonography (13-4 MHz) at the basal stage before the surgery, after the reperfusion stage and during the post-stroke status. At reperfusion stage and after, BFV increased significantly in the left ICA and in the basilar artery (BA) (starting from post-24 h, p < 0.05 vs. basal). Moreover, BFV were reversed in the distal right ICA and reflow was recorded in the right MCA. Time-average maximum BFV in the right MCA at reperfusion and post-stroke 24-96 h was decreased significantly (p < 0.05 vs. basal). The reversed flow in the right ICA was enabled by the settlement of the collateral supply through the circle of Willis which consisted in higher BFV in the opposite ICA and in the BA still 24 h, although the proximal right ICA remain occluded. Ultrasound measurement of BFV helps to provide information on the redistribution of the blood flow supply after the onset of stroke. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Laser Doppler anemometer signal processing for blood flow velocity measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borozdova, M A; Fedosov, I V; Tuchin, V V
A new method for analysing the signal in a laser Doppler anemometer based on the differential scheme is proposed, which provides the flow velocity measurement in strongly scattering liquids, particularly, blood. A laser Doppler anemometer intended for measuring the absolute blood flow velocity in animal and human near-surface arterioles and venules is developed. The laser Doppler anemometer signal structure is experimentally studied for measuring the flow velocity in optically inhomogeneous media, such as blood and suspensions of scattering particles. The results of measuring the whole and diluted blood flow velocity in channels with a rectangular cross section are presented. (lasermore » applications and other topics in quantum electronics)« less
Separation of Doppler radar-based respiratory signatures.
Lee, Yee Siong; Pathirana, Pubudu N; Evans, Robin J; Steinfort, Christopher L
2016-08-01
Respiration detection using microwave Doppler radar has attracted significant interest primarily due to its unobtrusive form of measurement. With less preparation in comparison with attaching physical sensors on the body or wearing special clothing, Doppler radar for respiration detection and monitoring is particularly useful for long-term monitoring applications such as sleep studies (i.e. sleep apnoea, SIDS). However, motion artefacts and interference from multiple sources limit the widespread use and the scope of potential applications of this technique. Utilising the recent advances in independent component analysis (ICA) and multiple antenna configuration schemes, this work investigates the feasibility of decomposing respiratory signatures into each subject from the Doppler-based measurements. Experimental results demonstrated that FastICA is capable of separating two distinct respiratory signatures from two subjects adjacent to each other even in the presence of apnoea. In each test scenario, the separated respiratory patterns correlate closely to the reference respiration strap readings. The effectiveness of FastICA in dealing with the mixed Doppler radar respiration signals confirms its applicability in healthcare applications, especially in long-term home-based monitoring as it usually involves at least two people in the same environment (i.e. two people sleeping next to each other). Further, the use of FastICA to separate involuntary movements such as the arm swing from the respiratory signatures of a single subject was explored in a multiple antenna environment. The separated respiratory signal indeed demonstrated a high correlation with the measurements made by a respiratory strap used currently in clinical settings.
Raisis, A L; Young, L E; Taylor, P M; Walsh, K P; Lekeux, P
2000-03-01
To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. 6 healthy adult horses. Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measure relative microvascular perfusion at a single site in the semimembranosus muscles. Phenylephrine or dobutamine was then administered to decrease or increase femoral arterial blood flow, and changes in blood flow and microvascular perfusion were recorded. Administration of phenylephrine resulted in significant decreases in femoral arterial and venous blood flows and cardiac output and significant increases in mean aortic blood pressure, systemic vascular resistance, and PCV. Administration of dobutamine resulted in significant increases in femoral arterial blood flow, mean aortic blood pressure, and PCV. Significant changes in microvascular perfusion were not detected. Results suggest that Doppler ultrasonography and single-fiber LDF can be used to study blood flows in the hind limbs of anesthetized horses. However, further studies are required to determine why changes in femoral arterial blood flows were not associated with changes in microvascular perfusion.
Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia.
Yoon, M J; Lee, S J; Kim, E; Park, S H
2012-01-01
To examine whether Doppler ultrasound can detect changes in pulpal blood flow after infiltration anaesthesia. Changes in pulpal blood flow in maxillary central incisor teeth of 18 patients (mean age 26.7 years, 13 men, five women) after infiltration anaesthesia were examined. Before infiltration anaesthesia, the pulpal blood flow was measured using Doppler ultrasound. A local anaesthetic solution containing 2% lidocaine with 1:80,000 epinephrine was injected into the submucosa above the experimental tooth. The Doppler ultrasound test was carried out at 5, 10, 20, 30, 45 and 60 min after infiltration. The parameters were Vas (maximum linear velocity, cm s(-1) ), Vam (average linear velocity, cm s(-1) ) and Vakd (minimum linear velocity, cm s(-1) ), which are indicators of the level of blood flow. The mixed procedure at the 95% confidence interval was used to examine the changes in pulpal blood flow after the injection. The linear velocity profiles (Vas, Vam, and Vakd) decreased sharply 5 min after anaesthesia and then reduced continuously for 30 min. The maximum degree of blood flow reduction in Vas, Vam and Vakd was 58%, 83% and 82%, respectively. After 30 min, the linear velocities increased gradually. The Vam returned to the pre-anaesthesia state at 60 minutes but the Vas and Vakd did not recover completely. Doppler ultrasound can detect changes in pulpal blood flow after infiltration anaesthesia. In the future, Doppler ultrasound can be used as a tool for measuring pulpal blood flow. © 2011 International Endodontic Journal.
[The use of intraoperative Doppler ultrasound in endoscopic transsphenoidal surgery].
Sharipov, O I; Kutin, M A; Kalinin, P L; Fomichev, D V; Lukshin, V A; Kurnosov, A B
2016-01-01
Doppler ultrasound (DUS) has been widely used in neurosurgical practice to diagnose various cerebrovascular diseases. This technique is used in transsphenoidal surgery to identify the localization of intracranial arteries when making an approach or during tumor resection. To identify the cavernous segment of the internal carotid artery (ICA) and/or basilar artery during endoscopic transsphenoidal surgery, we used a combined device on the basis of a click line curette («Karl Storz») and a 16 MHz Doppler probe (Lassamed). The technique was used in 51 patients during both standard transsphenoidal surgery (23 cases) and transsphenoidal tumor resection through an extended approach (28 cases). Doppler ultrasound was used in different situations: to determine a trajectory of the endonasal transsphenoidal approach in the absence of the normal anatomical landmarks (16 cases), to define the limits of safe resection of a tumor located in the laterosellar region (7), and to implement an extended transsphenoidal endoscopic approach (28). Intraoperative Doppler ultrasound enabled identification of the cavernous segment of the internal carotid artery in 45 cases and the basilar artery in 2 cases; a blood vessel was not found in 4 cases. Injury to the cavernous segment of the internal carotid artery was observed only in 1 case. The use of the described combined device in transsphenoidal surgery turned Doppler ultrasound into an important and useful technique for visualization of the ICA within the tumor stroma as well as in the case of the changed skull base anatomy. Its use facilitates manipulations in a deep and narrow wound and enables inspection of the entire surface of the operative field in various planes, thereby surgery becomes safer due to the possibility of maximum investigation of the operative field.
Blind ICA detection based on second-order cone programming for MC-CDMA systems
NASA Astrophysics Data System (ADS)
Jen, Chih-Wei; Jou, Shyh-Jye
2014-12-01
The multicarrier code division multiple access (MC-CDMA) technique has received considerable interest for its potential application to future wireless communication systems due to its high data rate. A common problem regarding the blind multiuser detectors used in MC-CDMA systems is that they are extremely sensitive to the complex channel environment. Besides, the perturbation of colored noise may negatively affect the performance of the system. In this paper, a new coherent detection method will be proposed, which utilizes the modified fast independent component analysis (FastICA) algorithm, based on approximate negentropy maximization that is subject to the second-order cone programming (SOCP) constraint. The aim of the proposed coherent detection is to provide robustness against small-to-medium channel estimation mismatch (CEM) that may arise from channel frequency response estimation error in the MC-CDMA system, which is modulated by downlink binary phase-shift keying (BPSK) under colored noise. Noncoherent demodulation schemes are preferable to coherent demodulation schemes, as the latter are difficult to implement over time-varying fading channels. Differential phase-shift keying (DPSK) is therefore the natural choice for an alternative modulation scheme. Furthermore, the new blind differential SOCP-based ICA (SOCP-ICA) detection without channel estimation and compensation will be proposed to combat Doppler spread caused by time-varying fading channels in the DPSK-modulated MC-CDMA system under colored noise. In this paper, numerical simulations are used to illustrate the robustness of the proposed blind coherent SOCP-ICA detector against small-to-medium CEM and to emphasize the advantage of the blind differential SOCP-ICA detector in overcoming Doppler spread.
Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
NASA Astrophysics Data System (ADS)
Adair, Henry S., III
1998-07-01
Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.
Developments in laser Doppler blood perfusion monitoring
NASA Astrophysics Data System (ADS)
Leahy, Martin J.; de Mul, Frits F. M.; Nilsson, Gert E.; Maniewski, Roman; Liebert, Adam
2003-03-01
This paper reviews the development and use of laser Doppler perfusion monitors and imagers. Despite their great success and almost universal applicability in microcirculation research, they have had great difficulty in converting to widespread clinical application. The enormous interest in microvascular blood perfusion coupled with the 'ease of use' of the technique has led to 2000+ publications citing its use. However, useful results can only be achieved with an understanding of the basic principles of the instrumentation and its application in the various clinical disciplines. The basic technical background is explored and definitions of blood perfusion and laser Doppler perfusion are established. The calibration method is then described together with potential routes to standardisation. A guide to the limitations in application of the technique gives the user a clear indication of what can be achieved in new studies as well as possible inadequacy in some published investigations. Finally some clinical applications have found acceptability and these will be explored.
Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli.
Moehring, Mark A; Spencer, Merrill P
2002-01-01
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm spacing was configured to display Doppler signal power, colored red and blue for directionality, in an M-mode format. The spectrogram from a user-selected depth was displayed simultaneously. This system was then explored on healthy subjects and patients presenting with varying cerebrovascular pathology. PMD facilitated window location and alignment of the US beam to view blood flow from multiple vessels simultaneously, without sound or spectral clues. Microemboli appeared as characteristic sloping high-power tracks in the PMD image. Power M-mode Doppler is a new paradigm facilitating vessel location, diagnosis, monitoring and microembolus detection.
Kim, Dohyun; Park, Sung-Ho
2016-11-01
Recently, Doppler ultrasound has been used for the measurement of pulpal blood flow in human teeth. However, the reliability of this method has not been verified. In this study, we developed a model to simulate arteriole blood flow within the dental pulp by using microfluidics. This arteriole simulator, or flow phantom, was used to determine the reliability of measurements obtained by using a Doppler ultrasound device. A microfluidic chip was fabricated by using the soft lithography technique, and blood-mimicking fluid was pumped through the channel by a microfluidic system. A Doppler ultrasound device was used for the measurement of flow velocity. The peak, mean, and minimal flow velocities obtained from the phantom and the Doppler ultrasound device were compared by using linear regression analysis and Pearson correlation coefficient. Bland-Altman analyses were performed to evaluate the velocity differences between the flow generated by the phantom and the flow measurements made with the Doppler ultrasound device. The microfluidic system was able to generate the flow profiles as intended, and the fluid flow could be monitored and controlled by the software program. There were excellent linear correlations between the peak, mean, and minimal flow velocities of the phantom and those of the Doppler ultrasound device (r = 0.94-0.996, P < .001). However, the velocities were overestimated by the Doppler ultrasound device. This phantom provides opportunities for research and education involving the Doppler ultrasound technique in dentistry. Although Doppler ultrasound can be an effective tool for the measurement of pulpal blood flow velocity, it is essential to validate and calibrate the device before clinical use. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Reif, Roberto; Zhi, Zhongwei; Dziennis, Suzan; Nuttall, Alfred L; Wang, Ruikang K
2013-10-01
In this work we determined the contributions of loud sound exposure (LSE) on cochlear blood flow (CoBF) in an in vivo anesthetized mouse model. A broadband noise system (20 kHz bandwidth) with an intensity of 119 dB SPL, was used for a period of one hour to produce a loud sound stimulus. Two techniques were used to study the changes in blood flow, a Doppler optical microangiography (DOMAG) system; which can measure the blood flow within individual cochlear vessels, and a laser Doppler flowmetry (LDF) system; which averages the blood flow within a volume (a hemisphere of ~1.5 mm radius) of tissue. Both systems determined that the blood flow within the cochlea is reduced due to the LSE stimulation.
In vivo photoacoustic tomography of total blood flow and Doppler angle
NASA Astrophysics Data System (ADS)
Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2012-02-01
As two hallmarks of cancer, angiogenesis and hypermetabolism are closely related to increased blood flow. Volumetric blood flow measurement is important to understanding the tumor microenvironment and developing new means to treat cancer. Current photoacoustic blood flow estimation methods focus on either the axial or transverse component of the flow vector. Here, we propose a method to compute the total flow speed and Doppler angle by combining the axial and transverse flow measurements. Both the components are measured in M-mode. Collating the A-lines side by side yields a 2D matrix. The columns are Hilbert transformed to compare the phases for the computation of the axial flow. The rows are Fourier transformed to quantify the bandwidth for the computation of the transverse flow. From the axial and transverse flow components, the total flow speed and Doppler angle can be derived. The method has been verified by flowing bovine blood in a plastic tube at various speeds from 0 to 7.5 mm/s and at Doppler angles from 30 to 330°. The measurement error for total flow speed was experimentally determined to be less than 0.3 mm/s; for the Doppler angle, it was less than 15°. In addition, the method was tested in vivo on a mouse ear. The advantage of this method is simplicity: No system modification or additional data acquisition is required to use our existing system. We believe that the proposed method has the potential to be used for cancer angiogenesis and hypermetabolism imaging.
Blood flow velocity measurement by endovascular Doppler optical coherence tomography
NASA Astrophysics Data System (ADS)
Sun, Cuiru; Nolte, Felix; Vuong, Barry; Cheng, Kyle H. Y.; Lee, Kenneth K. C.; Standish, Beau A.; Courtney, Brian; Marotta, Tom R.; Yang, Victor X. D.
2013-03-01
Blood flow velocity and volumetric flow measurements are important parameters for assessment of the severity of stenosis and the outcome of interventional therapy. However, feasibility of intravascular flow measurement using a rotational catheter based phase resolved Doppler optical coherence tomography (DOCT) is difficult. Motion artefacts induced by the rotating optical imaging catheter, and the radially dependent noise background of measured Doppler signals are the main challenges encountered. In this study, a custom-made data acquisition system and developed algorithms to remove non-uniform rotational distortion (NURD) induced phase shift artefact by tracking the phase shift observed on catheter sheath. The flow velocity is calculated from Doppler shift obtained by Kasai autocorrelation after motion artefact removal. Blood flow velocity profiles in porcine carotid arteries in vivo were obtained at 100 frames/s with 500 A-lines/frame and DOCT images were taken at 20 frames/s with 2500 A-lines/frame. Time-varying velocity profiles were obtained at an artery branch. Furthermore, the identification of a vein adjacent to the catheterized vessel based on the color Doppler signal was also observed. The absolute measurement of intravascular flow using a rotating fiber catheter can provide insights to different stages of interventional treatment of stenosis in carotid artery.
Color Doppler ultrasound evaluation of testicular blood flow in stallions.
Pozor, M A; McDonnell, S M
2004-04-01
The objectives of this study were to evaluate the potential use of color Doppler ultrasound to characterize blood flow to the stallion testis, and to establish reference values for Doppler measures of blood flow in the testicular artery of the stallion. Both testes from each of 52 horses were examined using a pulsed-wave color Doppler ultrasound with a sector array 5/7.5 MHz transducer with a 1mm gate setting. Peak systolic velocity (PSV), end diastolic velocity (EDV), resistive index (RI), and pulsatility index (PI) of the testicular artery were measured in each of two locations, the convoluted aspect (spermatic cord) and the marginal aspect of the artery (on the epididymal edge of testis). We found that: (1) all measures were obtainable; (2) except for EDV, the majority of the measures were higher at the cord location than at the marginal aspect of the artery (P < 0.05); and (3) measures for left and right testes were similar (P > 0.10). Resulting measures from 41 of these stallions (82 testes) that appeared free of testicular pathology provide useful reference values for clinical evaluation. Evaluation of 11 cases with testicular pathology suggested further investigation of possible effects of these various conditions on testicular blood flow and testicular function.
Ultrasonic Doppler measurement of renal artery blood flow
NASA Technical Reports Server (NTRS)
1974-01-01
Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.
3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.
Provost, Jean; Papadacci, Clement; Demene, Charlie; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu
2015-08-01
Ultrafast Doppler imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D ultrafast ultrasound imaging, a technique that can produce thousands of ultrasound volumes per second, based on a 3-D plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that noninvasive 3-D ultrafast power Doppler, pulsed Doppler, and color Doppler imaging can be used to perform imaging of blood vessels in humans when using coherent compounding of 3-D tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D ultrafast imaging. Using a 32 × 32, 3-MHz matrix phased array (Vermon, Tours, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. The proof of principle of 3-D ultrafast power Doppler imaging was first performed by imaging Tygon tubes of various diameters, and in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D color and pulsed Doppler imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer.
Carotid duplex ultrasound and transcranial Doppler findings in commercial divers and pilots.
Dormanesh, Banafshe; Vosoughi, Kia; Akhoundi, Fahimeh H; Mehrpour, Masoud; Fereshtehnejad, Seyed-Mohammad; Esmaeili, Setareh; Sabet, Azin Shafiee
2016-12-01
The risky working environments of divers and pilots, and the possible role of extreme ambient pressure in carotid stenosis, make ischemic stroke an important occupational concern among these professionals. In this study, we aimed to evaluate the association of being exposed to hyperbaric or hypobaric conditions with carotid artery stenosis by comparing common carotid intima-media thickness (CCIMT) and blood flow velocities of cerebral arteries in divers and pilots using carotid duplex ultrasound (CDUS) and transcranial Doppler (TCD). CDUS and transtemporal TCD were performed in 29 divers, 36 pilots and 30 control participants. Medical history, blood pressure, lipid profile and blood sugar were recorded to control the previously well-known risk factors of atherosclerosis. Findings of the CDUS and TCD [including: CCIMT and blood flow velocities of internal carotid artery (ICA), common carotid artery (CCA), and middle cerebral artery (MCA)] of divers and pilots were compared with those of the control group using regression analysis models. Both right and left side CCIMT were significantly higher in divers (P < 0.05) and pilots (P < 0.05) in comparison with the control group. Carotid index [peak systolic velocity (PSV) of ICA/PSV of CCA) of divers and pilots were also higher than the control group. TCD findings were not significantly different between divers, pilots, and the control group. Increased CCIMT and carotid index in diver and pilot groups appear to be suggestive of accelerated atherosclerosis of carotid artery in these occupational groups.
The effect of blood acceleration on the ultrasound power Doppler spectrum
NASA Astrophysics Data System (ADS)
Matchenko, O. S.; Barannik, E. A.
2017-09-01
The purpose of the present work was to study the influence of blood acceleration and time window length on the power Doppler spectrum for Gaussian ultrasound beams. The work has been carried out on the basis of continuum model of the ultrasound scattering from inhomogeneities in fluid flow. Correlation function of fluctuations has been considered for uniformly accelerated scatterers, and the resulting power Doppler spectra have been calculated. It is shown that within the initial phase of systole uniformly accelerated slow blood flow in pulmonary artery and aorta tends to make the correlation function about 4.89 and 7.83 times wider, respectively, than the sensitivity function of typical probing system. Given peak flow velocities, the sensitivity function becomes, vice versa, about 4.34 and 3.84 times wider, respectively, then the correlation function. In these limiting cases, the resulting spectra can be considered as Gaussian. The optimal time window duration decreases with increasing acceleration of blood flow and equals to 11.62 and 7.54 ms for pulmonary artery and aorta, respectively. The width of the resulting power Doppler spectrum is shown to be defined mostly by the wave vector of the incident field, the duration of signal and the acceleration of scatterers in the case of low flow velocities. In the opposite case geometrical properties of probing field and the average velocity itself are more essential. In the sense of signal-noise ratio, the optimal duration of time window can be found. Abovementioned results may contribute to the improved techniques of Doppler ultrasound diagnostics of cardiovascular system.
Huang, Chih-Chung; Lee, Po-Yang; Chen, Pay-Yu; Liu, Ting-Yu
2012-01-01
Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications. © 2012 IEEE
gpICA: A Novel Nonlinear ICA Algorithm Using Geometric Linearization
NASA Astrophysics Data System (ADS)
Nguyen, Thang Viet; Patra, Jagdish Chandra; Emmanuel, Sabu
2006-12-01
A new geometric approach for nonlinear independent component analysis (ICA) is presented in this paper. Nonlinear environment is modeled by the popular post nonlinear (PNL) scheme. To eliminate the nonlinearity in the observed signals, a novel linearizing method named as geometric post nonlinear ICA (gpICA) is introduced. Thereafter, a basic linear ICA is applied on these linearized signals to estimate the unknown sources. The proposed method is motivated by the fact that in a multidimensional space, a nonlinear mixture is represented by a nonlinear surface while a linear mixture is represented by a plane, a special form of the surface. Therefore, by geometrically transforming the surface representing a nonlinear mixture into a plane, the mixture can be linearized. Through simulations on different data sets, superior performance of gpICA algorithm has been shown with respect to other algorithms.
Transdural doppler ultrasonography monitors cerebral blood flow changes in relation to motor tasks.
Hatanaka, Nobuhiko; Tokuno, Hironobu; Nambu, Atsushi; Takada, Masahiko
2009-04-01
Monitoring changes in cerebral blood flow in association with neuronal activity has widely been used to evaluate various brain functions. However, current techniques do not directly measure blood flow changes in specified blood vessels. The present study identified arterioles within the cerebral cortex by echoencephalography and color Doppler imaging, and then measured blood flow velocity (BFV) changes in pulsed-wave Doppler mode. We applied this "transdural Doppler ultrasonography (TDD)" to examine BFV changes in the cortical motor-related areas of monkeys during the performance of unimanual (right or left) and bimanual key-press tasks. BFV in the primary motor cortex (MI) was increased in response to contralateral movement. In each of the unimanual and bimanual tasks, bimodal BFV increases related to both the instruction signal and the movement were observed in the supplementary motor area (SMA). Such BFV changes in the SMA were prominent during the early stage of task training and gradually decreased with improvements in task performance, leaving those in the MI unchanged. Moreover, BFV changes in the SMA depended on task difficulty. The present results indicate that TDD is useful for evaluating regional brain functions.
Wang, Yimin; Fawzi, Amani; Tan, Ou; Gil-Flamer, John; Huang, David
2010-01-01
We present human retinal blood flow investigation for diabetic patients using Doppler Fourier domain optical coherence tomography (FD-OCT). The scanning pattern consisted of two concentric circles around the optic nerve head. The blood flow in one patient with diabetes and no retinpathy and another patient with treated proliferative diabetic retinopathy were measured. The patient without retinopathy showed a total blood flow value at the lower level of the normal range. The flow distribution between superior and inferior retina was balanced. The patient with diabetic retinopathy had a flow value lower than the normal people. Our study shows that Doppler FD-OCT can be used to evaluate the total retinal blood flow in patients with retinal diseases. PMID:19259246
Evaluation of extracranial blood flow in Parkinson disease.
Haktanir, Alpay; Yaman, Mehmet; Acar, Murat; Gecici, Omer; Demirel, Reha; Albayrak, Ramazan; Demirkirkan, Kemal
2006-01-02
Decreased cerebral flow velocities in Parkinsonian patients were reported previously. Because of the limited data on vascular changes in Parkinson disease (PD), which may have a vascular etiology, we aimed to disclose any possible cerebral hemodynamic alteration in Parkinsonian patients. We prospectively evaluated 28 non-demented, idiopathic parkinsonian patients and 19 age and sex matched controls with Doppler sonography. Flow volumes, peak systolic flow velocities, and cross-sectional areas of vertebral and internal carotid arteries (ICA) were measured and compared between patients and controls. Correlation of patient age and disease duration with Doppler parameters was observed; and each Doppler parameter of patients within each Hoehn-Yahr scale was compared. There was no significant difference of measured parameters between groups. No correlation was found between disease duration and age with flow volume, cross-sectional area or peak systolic velocity. Hoehn-Yahr scale was not found having significant relation with Doppler parameters. Values of vertebral, internal carotid and cerebral blood flow volumes (CBF), peak systolic velocities, and cross-sectional areas were not significantly different between Parkinsonian patients and age and sex matched controls. Although regional blood flow decreases may be seen as reported previously, Parkinson disease is not associated with a flow volume or velocity alteration of extracranial cerebral arteries.
NASA Astrophysics Data System (ADS)
Volkov, M. V.; Kostrova, D. A.; Margaryants, N. B.; Gurov, I. P.; Erofeev, N. P.; Dremin, V. V.; Zharkikh, E. V.; Zherebtsov, E. A.; Kozlov, I. O.; Dunaev, A. V.
2017-03-01
Laser Doppler flowmetry (LDF) is widely used for diagnosing blood microcirculation diseases. It is well known that the Doppler shift of laser radiation scattered by moving red blood cells (RBC) can be assessed through analyzing photocurrent produced by a photodetector. LDF signal contains information about regulating blood flow rhythms: myogenic, cardiac, nervous and endothelial. The method of videocapillaroscopy (VCS) allows local capillary blood flow velocity evaluation and, using video data processing algorithms, is able to assess RBC velocity changes into capillary. We present the results of simultaneous investigations of changes in tissue perfusion of the distal phalanx of human finger by the LDF as well as changes in capillary blood flow velocity in the nail bed evaluated by the VCS method during arterial occlusion test. The experimental results confirmed the correspondence between blood perfusion and blood flow velocity.
Ultrasonic Doppler measurement of renal artery blood flow
NASA Technical Reports Server (NTRS)
Freund, W. R.; Meindl, J. D.
1975-01-01
An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.
Provost, J.; Papadacci, C.; Demene, C.; Gennisson, J-L.; Tanter, M.; Pernot, M.
2016-01-01
Ultrafast Doppler Imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D Ultrafast Ultrasound Imaging, a technique that can produce thousands of ultrasound volumes per second, based on three-dimensional plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that non-invasive 3-D Ultrafast Power Doppler, Pulsed Doppler, and Color Doppler Imaging can be used to perform quantitative imaging of blood vessels in humans when using coherent compounding of three-dimensional tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D Ultrafast Imaging. Using a 32X32, 3-MHz matrix phased array (Vermon, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. 3-D Ultrafast Power Doppler Imaging was first validated by imaging Tygon tubes of varying diameter and its in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D Color and Pulsed Doppler Imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer. PMID:26276956
Novel laser Doppler flowmeter for pulpal blood flow measurements
NASA Astrophysics Data System (ADS)
Zang, De Yu; Millerd, James E.; Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.
1996-04-01
We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality of a tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induced pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back- scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.
Evaluation of transplant renal artery blood flow by Doppler sound-spectrum analysis.
Reinitz, E R; Goldman, M H; Sais, J; Rittgers, S E; Lee, H M; Mendez-Picon, G; Muakkassa, W F; Barnes, R W
1983-04-01
Doppler ultrasonography sound-spectrum analysis (SSA) was used to evaluate blood flow in the transplanted kidney and its renal artery. Seven patients with posttransplant hypertension and a bruit over the transplanted kidney were screened for renal artery stenosis (RAS). In five patients, RAS was diagnosed by SSA, and in two it was not. These findings were confirmed by subsequent angiography in all patients. Three patients studied after surgical correction of their RAS had improvement in their SSA patterns. Fourteen hypertensive patients with a cause other than RAS were evaluated by SSA. None of them had SSA findings suggestive of RAS. Doppler ultrasonography with SSA is an effective, noninvasive technique of monitoring transplant renal blood flow, especially in the screening of hypertensive transplant recipients for transplant RAS.
2014-09-01
flow velocity in the MCA and ICA of patients with known vasospasm, as compared to standard TCD run by a trained neurosonographer. Proposed study: Use...the middle cerebral artery (MCA) and internal carotid artery (ICA) of patients with known vasospasm, as compared to standard TCD run by a trained ...Wechsler LR, Toole JF (eds). Transcranial Doppler Ultrasonography. Boston, MA: Butterworth- Heinemann; 1999:109–128. 2. Aaslid R, Nornes H. Musical
Washio, Takuro; Sasaki, Hiroyuki; Ogoh, Shigehiko
2017-04-01
We examined whether a change in posterior cerebral artery flow velocity (PCAv) reflected the posterior cerebral blood flow in healthy subjects during both static and dynamic exercise. PCAv and vertebral artery (VA) blood flow, as an index of posterior cerebral blood flow, were continuously measured during an exercise trial using transcranial Doppler (TCD) ultrasonography and Doppler ultrasound, respectively. Static handgrip exercise significantly increased both PCAv and VA blood flow. Increasing intensity of dynamic exercise further increased VA blood flow from moderate exercise, while PCAv decreased to almost resting level. During both static and dynamic exercise, the PCA cerebrovascular conductance (CVC) index significantly decreased from rest (static and high-intensity dynamic exercise, -11.5 ± 12.2% and -18.0 ± 16.8%, means ± SD, respectively) despite no change in the CVC of VA. These results indicate that vasoconstriction occurred at PCA but not VA during exercise-induced hypertension. This discrepancy in vascular response to exercise between PCA and VA may be due to different cerebral arterial characteristics. Therefore, to determine the effect of exercise on posterior cerebral circulation, at least, we need to carefully consider which cerebral artery to measure, regardless of exercise mode. NEW & NOTEWORTHY We examined whether transcranial Doppler-determined flow velocity in the posterior cerebral artery can be used as an index of cerebral blood flow during exercise. However, the changes in posterior cerebral artery flow velocity during exercise do not reflect vertebral artery blood flow. Copyright © 2017 the American Physiological Society.
A feasability study of color flow doppler vectorization for automated blood flow monitoring.
Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D
2017-12-01
An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.
Raisis, A L; Young, L E; Meire, H; Walsh, K; Taylor, P M; Lekeux, P
2000-05-01
The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI). Within-patient variability was determined for sequential Doppler measurements recorded during a single standardised anaesthetic episode. Within-patient variability was also determined for Doppler and cardiovascular measurements recorded during 4 separate standardised anaesthetic episodes performed at intervals of at least one month. Within-patient variation during a single anaesthetic episode was small. Coefficients of variation (cv) were <12.5% for arterial measurements and <17% for venous measurements. Intraclass correlation coefficient was >0.75 for all measurements. No significant change was observed in measurements of cardiovascular function suggesting that within-patient variation observed during a single anaesthetic episode was due to measurement error. In contrast, within-patient variation during 4 separate anaesthetic episodes was marked (cv>17%) for most Doppler measurements obtained from arteries and veins. Variation in measurements of cardiovascular function were marked (cv>20%), suggesting that there is marked biological variation in central and peripheral observed. Further studies are warranted to determine the ability of this technique to detect differences in blood flow during administration of different anaesthetic agents.
Rothfuss, Michael A; Unadkat, Jignesh V; Gimbel, Michael L; Mickle, Marlin H; Sejdić, Ervin
2017-03-01
Totally implantable wireless ultrasonic blood flowmeters provide direct-access chronic vessel monitoring in hard-to-reach places without using wired bedside monitors or imaging equipment. Although wireless implantable Doppler devices are accurate for most applications, device size and implant lifetime remain vastly underdeveloped. We review past and current approaches to miniaturization and implant lifetime extension for wireless implantable Doppler devices and propose approaches to reduce device size and maximize implant lifetime for the next generation of devices. Additionally, we review current and past approaches to accurate blood flow measurements. This review points toward relying on increased levels of monolithic customization and integration to reduce size. Meanwhile, recommendations to maximize implant lifetime should include alternative sources of power, such as transcutaneous wireless power, that stand to extend lifetime indefinitely. Coupling together the results will pave the way for ultra-miniaturized totally implantable wireless blood flow monitors for truly chronic implantation. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Morel, O; Pachy, F; Chavatte-Palmer, P; Bonneau, M; Gayat, E; Laigre, P; Evain-Brion, D; Tsatsaris, V
2010-11-01
Three-dimensional (3D) Doppler quantification within the uteroplacental unit could be of great help in understanding and screening for pre-eclampsia and intrauterine growth restriction. Yet the correlation between 3D Doppler indices and true blood flow has not been confirmed in vivo. The aim of this study was to evaluate this correlation in a pregnant sheep model. A blood flow quantitative sensor and a controllable vascular occlusion system were placed around the common uterine artery in seven sheep in late pregnancy, while all the other arterial supplies were ligated. Several occlusion levels were applied, from 0 to 100%, simultaneously with 3D Doppler acquisitions of several placentomes, using standardized settings. Each placentome was analyzed using VOCAL™ (Virtual Organ Computer-aided AnaLysis) software. The correlation between true blood flow and Doppler indices (vascularization index (VI), flow index (FI) and vascularization flow index (VFI)) was evaluated, together with measurement reproducibility. Forty-eight acquisitions were analyzed. All 3D Doppler indices were significantly correlated with true blood flow. Higher correlations were observed for VI and VFI (r = 0.81 (0.74-0.87), P < 0.0001 and r = 0.75 (0.67-0.82), P < 0.0001) compared with FI (r = 0.53 (0.38-0.64) P < 0.0001). Both intra- and interobserver reproducibility were high, with intraclass correlation coefficients of at least 0.799. This is the first in-vivo experimental study confirming a significant correlation between true blood perfusion and quantitative 3D Doppler indices measured within the uteroplacental unit. These results confirm the potential usefulness of 3D Doppler ultrasound for the assessment of placental vascular insufficiency both in clinical cases and in a research setting. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography.
Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L; Wang, Ruikang K
2012-10-01
Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ∼1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ∼80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.
Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography
NASA Astrophysics Data System (ADS)
Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L.; Wang, Ruikang K.
2012-10-01
Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ˜1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ˜80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.
Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.
2015-01-01
Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length. PMID:26328984
Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F
2015-09-01
Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Wenzhong; Yi, Ji; Chen, Siyu
Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (smallmore » ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.« less
Ultrasonic Doppler blood flow meter for extracorporeal circulation
NASA Astrophysics Data System (ADS)
Dantas, Ricardo G.; Costa, Eduardo T.; Maia, Joaquim M.; Nantes Button, Vera L. d. S.
2000-04-01
In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient's body, in a procedure known as extracorporeal circulation (EC). During this procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2 MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53 mm). The experimental results using the developed flowmeter indicated a maximum deviation of 3.5% of full scale, while the blood flow estimator based in the rotation speed of the peristaltic pump presented deviations greater than 20% of full scale. This ultrasonic flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use.
NASA Astrophysics Data System (ADS)
Tan, Bingyao; Hosseinaee, Zohreh; Bizheva, Kostadinka
2017-11-01
The variability in the spatial orientation of retinal blood vessels near the optic nerve head (ONH) results in imprecision of the measured Doppler angle and therefore the pulsatile blood flow (BF), when those parameters are evaluated using Doppler OCT imaging protocols based on dual-concentric circular scans. Here, we utilized a dense concentric circle scanning protocol and evaluated its precision for measuring pulsatile retinal BF in rats for different numbers of the circular scans. An spectral domain optical coherence tomography (SD-OCT) system operating in the 1060-nm spectral range with image acquisition rate of 47,000 A-scans/s was used to acquire concentric circular scans centered at the rat's ONH, with diameters ranging from 0.8 to 1.0 mm. A custom, automatic blood vessel segmentation algorithm was used to track the spatial orientation of the retinal blood vessels in three dimensions, evaluate the spatially dependent Doppler angle and calculate more accurately the axial BF for each major retinal blood vessel. Metrics such as retinal BF, pulsatility index, and resistance index were evaluated for each and all of the major retinal blood vessels. The performance of the proposed dense concentric circle scanning protocols was compared with that of the dual-circle scanning protocol. Results showed a 3.8±2.2 deg difference in the Doppler angle calculation between the two approaches, which resulted in ˜7% difference in the calculated retinal BF.
Evaluation of contrast-enhanced power Doppler imaging for measuring blood flow
NASA Astrophysics Data System (ADS)
Ansaloni, Sara; Arger, Peter H.; Cary, Ted W.; Sehgal, Chandra M.
2005-04-01
Power Doppler ultrasound enhanced by microbubble contrast agent has been used to image tissue vascularity and blood flow for the assessment of antivascular therapies. We have proposed a multigating technique that measures bubble concentration as a function of ultrasound exposure for deriving tumor blood flow and vascularity.1 Techniques using ultrasound contrast agent are known to be sensitive to the choice of imaging parameters like mechanical index and tissue attenuation. In this paper, the roles of mechanical index (MI) and tissue attenuation were evaluated experimentally in a rubber tubing flow phantom connected to a mixing chamber and a variable speed pump. The contrast was injected in the mixing chamber and the flow rate was measured using power Doppler imaging. The measurements were repeated at different MIs (0.1 to 1.3), and at different levels of attenuation, obtained with solutions of glycerol-water (10-20%). True flow was measured by collecting liquid flowing out of the phantom over a fixed duration. At low MI (<0.5), the grayscale and Doppler signal were weak, making these images unsuitable for analysis. At higher MI (> 0.8), there was a well-defined enhancement by contrast agent resulting in reproducible flow measurements at variable MIs. A balance between the number of bubbles destroyed and the echo they generate must be achieved for optimal imaging. The increased attenuation of ultrasound by the overlying medium did not influence the flow measurements.
NASA Astrophysics Data System (ADS)
Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping
2017-02-01
Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it not only relates to the properties of the laser and the scattering particles, but also relates to the geometry of both directions of the laser beam and the flow. In this paper, focusing on the analysis of cerebral hemodynamics, we presents a method to quantify the total absolute blood flow velocity in middle cerebral artery (MCA) based on volumetric vessel reconstruction from pure DOCT images. A modified region growing segmentation method is first used to localize the MCA on successive DOCT B-scan images. Vessel skeletonization, followed by an averaging gradient angle calculation method, is then carried out to obtain Doppler angles along the entire MCA. Once the Doppler angles are determined, the absolute blood flow velocity of each position on the MCA is easily found. Given a seed point position on the MCA, our approach could achieve automatic quantification of the fully distributed absolute BFV. Based on experiments conducted using a swept-source optical coherence tomography system, our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches in the rodent brain.
Comparative laser Doppler measurement on tooth pulp blood flow at 632 and 750 nm
NASA Astrophysics Data System (ADS)
Oberg, P. Ake; Pettersson, Hans; Rohman, Hakan
1993-12-01
Laser-Doppler flowmetry has been used for the assessment of pulp blood flow in health and disease. General purpose laser Doppler instruments working at the Helium-Neon (632,8 nm) as well as IR (750 - 810 nm) wavelengths have been used in this application. Specially designed handheld equipment has also been used to assess blood supply to the tooth. A considerable difference in the measurement results have been noticed when using different wavelengths and probe designs. In this study some of the problems related to the use of various wavelengths and probe designs are studied in human teeth and in a physical model of a tooth. Our results support the early observation that measurements at different wavelengths and with different probe designs cannot be directly compared.
Zhang, Yingyun; Zhang, Yufeng; Gao, Lian; Deng, Li; Hu, Xiao; Zhang, Kexin; Li, Haiyan
2017-11-01
This study assessed the variation in the frequency locations in the Doppler ultrasound spectra for the maximum blood flow velocities of in vessels with different degrees of bilaterally axisymmetric stenosis. This was done by comparing the relationship between the velocity distributions and corresponding Doppler power spectra. First, a geometric vessel model with axisymmetric stenosis was established. This made it possible to obtain the blood flow velocity distributions for different degrees of stenosis from the solutions of the Navier-Stokes equations. Then, the Doppler spectra were calculated for the entire segment of the vessel that was covered by the sound field. Finally, the maximum frequency locations for the spectra were determined based on the intersections of the maximum values chosen from the calculated blood flow velocity distributions and their corresponding spectra. The computational analysis showed that the maximum frequencies, which corresponded to the maximum blood flow velocities for different degrees of stenosis, were located at different positions along the spectral falling edges. The location for a normal (stenosis free) vessel was in the middle of the falling edge. For vessels with increasing degrees of stenosis, this location shifted approximately linearly downward along the falling edge. For 40% stenosis, the location reached a position at the falling edge of 0.32. Results obtained using the Field II simulation tool demonstrated the validity of the theoretical analysis and calculations, and may help to improve the maximum velocity estimation accuracy for Doppler blood flow spectra in stenosed vessels. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Source-space ICA for MEG source imaging.
Jonmohamadi, Yaqub; Jones, Richard D
2016-02-01
One of the most widely used approaches in electroencephalography/magnetoencephalography (MEG) source imaging is application of an inverse technique (such as dipole modelling or sLORETA) on the component extracted by independent component analysis (ICA) (sensor-space ICA + inverse technique). The advantage of this approach over an inverse technique alone is that it can identify and localize multiple concurrent sources. Among inverse techniques, the minimum-variance beamformers offer a high spatial resolution. However, in order to have both high spatial resolution of beamformer and be able to take on multiple concurrent sources, sensor-space ICA + beamformer is not an ideal combination. We propose source-space ICA for MEG as a powerful alternative approach which can provide the high spatial resolution of the beamformer and handle multiple concurrent sources. The concept of source-space ICA for MEG is to apply the beamformer first and then singular value decomposition + ICA. In this paper we have compared source-space ICA with sensor-space ICA both in simulation and real MEG. The simulations included two challenging scenarios of correlated/concurrent cluster sources. Source-space ICA provided superior performance in spatial reconstruction of source maps, even though both techniques performed equally from a temporal perspective. Real MEG from two healthy subjects with visual stimuli were also used to compare performance of sensor-space ICA and source-space ICA. We have also proposed a new variant of minimum-variance beamformer called weight-normalized linearly-constrained minimum-variance with orthonormal lead-field. As sensor-space ICA-based source reconstruction is popular in EEG and MEG imaging, and given that source-space ICA has superior spatial performance, it is expected that source-space ICA will supersede its predecessor in many applications.
Srinivas, Sowmya; Tan, Ou; Wu, Shuang; Nittala, Muneeswar Gupta; Huang, David; Varma, Rohit; Sadda, SriniVas R
2015-02-10
To measure total retinal blood flow (TRBF) in normal, healthy Chinese Americans by using semi-automated analysis of Doppler Fourier-domain optical coherence tomography (FD-OCT) scans. Two hundred sixty-six normal, healthy Chinese-American participants (266 eyes) were enrolled from The Chinese American Eye Study. All participants underwent complete ophthalmic examination, including best-corrected visual acuity, indirect ophthalmoscopy, and Doppler FD-OCT imaging, using the circumpapillary double circular scan protocol. Total retinal blood flow and other vascular parameters (e.g., venous and arterial cross-sectional area and their velocities) were calculated by using Doppler OCT of Retinal Circulation software. Associations between TRBF and other clinical parameters were assessed by using bivariate correlations and linear regression. The mean age of study participants was 57.40 ± 5.60 (range, 50-82) years. The mean TRBF was 49.34 ± 10.08 (range, 27.17-78.08, 95% confidence interval: 25.98-69.10) μL/min. The mean venous area was 0.0548 (±0.0084) mm(2). Superior retinal hemispheric blood flow (25.50 ± 6.62 μL/min) was slightly greater than inferior retinal hemispheric blood flow (23.84 ± 7.19 μL/min, P = 0.008). The mean flow velocity was 15.16 ± 3.12 mm/s. There was a weak but significant negative correlation between TRBF and age (r = -0.15, P = 0.012). No significant correlation was found between TRBF and axial length (r = 0.11, P = 0.08). Retinal blood flow was not significantly correlated with any other clinical parameters, including body mass index, systolic blood pressure, diastolic blood pressure, and intraocular pressure. Normal Doppler OCT-derived total retinal blood values in a Chinese-American population showed considerable variability, some of which was explained by age. These observations should help design future studies evaluating TRBF in populations with eye disease. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Stocker, Jonathan W; De Franceschi, Lucia; McNaughton-Smith, Grant A; Corrocher, Roberto; Beuzard, Yves; Brugnara, Carlo
2003-03-15
A prominent feature of sickle cell anemia is the presence of dehydrated red blood cells (RBCs) in circulation. Loss of potassium (K(+)), chloride (Cl(-)), and water from RBCs is thought to contribute to the production of these dehydrated cells. One main route of K(+) loss in the RBC is the Gardos channel, a calcium (Ca(2+))-activated K(+) channel. Clotrimazole (CLT), an inhibitor of the Gardos channel, has been shown to reduce RBC dehydration in vitro and in vivo. We have developed a chemically novel compound, ICA-17043, that has greater potency and selectivity than CLT in inhibiting the Gardos channel. ICA-17043 blocked Ca(2+)-induced rubidium flux from human RBCs with an IC(50) value of 11 +/- 2 nM (CLT IC(50) = 100 +/- 12 nM) and inhibited RBC dehydration with an IC(50) of 30 +/- 20 nM. In a transgenic mouse model of sickle cell disease (SAD), treatment with ICA-17043 (10 mg/kg orally, twice a day) for 21 days showed a marked and constant inhibition of the Gardos channel activity (with an average inhibition of 90% +/- 27%, P <.005), an increase in RBC K(+) content (from 392 +/- 19.9 to 479.2 +/- 40 mmol/kg hemoglobin [Hb], P <.005), a significant increase in hematocrit (Hct) (from 0.435 +/- 0.007 to 0.509 +/- 0.022 [43.5% +/- 0.7% to 50.9% +/- 2.2%], P <.005), a decrease in mean corpuscular hemoglobin concentration (MCHC) (from 340 +/- 9.0 to 300 +/- 15 g/L [34.0 +/- 0.9 to 30 +/- 1.5 g/dL], P <.05), and a left-shift in RBC density curves. These data indicate that ICA-17043 is a potent inhibitor of the Gardos channel and ameliorates RBC dehydration in the SAD mouse.
Krejza, J; Rudzinski, W; Pawlak, M A; Tomaszewski, M; Ichord, R; Kwiatkowski, J; Gor, D; Melhem, E R
2007-09-01
Nonimaging transcranial Doppler sonography (TCD) and imaging TCD (TCDI) are used for determination of the risk of stroke in children with sickle cell disease (SCD). The purpose was to compare angle-corrected, uncorrected TCDI, and TCD blood flow velocities in children with SCD. A total of 37 children (mean age, 7.8 +/- 3.0 years) without intracranial arterial narrowing determined with MR angiography, were studied with use of TCD and TCDI at the same session. Depth of insonation and TCDI mean velocities with and without correction for the angle of insonation in the terminal internal carotid artery (ICA) and middle (MCA), anterior (ACA), and posterior (PCA) cerebral arteries were compared with TCD velocities with use of a paired t test. Two arteries were not found on TCDI compared with 15 not found on TCD. Average angle of insonation in the MCA, ACA, ICA, and PCA was 31 degrees , 44 degrees , 25 degrees , and 29 degrees , respectively. TCDI and TCD mean depth of insonation for all arteries did not differ significantly; however, individual differences varied substantially. TCDI velocities were significantly lower than TCD velocities, respectively, for the right and left sides (mean +/- SD): MCA, 106 +/- 22 cm/s and 111 +/- 33 cm/s versus 130 +/- 19 cm/s and 134 +/- 26 cm/s; ICA, 90 +/- 14 cm/s and 98 +/- 27 cm/s versus 117 +/- 18 cm/s and 119 +/- 23 cm/s; ACA, 74 +/- 24 cm/s and 88 +/- 25 cm/s versus 105 +/- 23 cm/s and 105 +/- 31 cm/s; and PCA, 84 +/- 27 cm/s and 82 +/- 21 cm/s versus 95 +/- 23 cm/s and 94 +/- 20 cm/s. TCD and angle-corrected TCDI velocities were not statistically different except for higher angle-corrected TCDI values in the left ACA and right PCA. TCD velocities are significantly higher than TCDI velocities but are not different from the angle-corrected TCDI velocities. TCDI identifies the major intracranial arteries more effectively than TCD.
Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.
Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A
2017-06-06
Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.
NASA Astrophysics Data System (ADS)
Vuong, Barry; Genis, Helen; Wong, Ronnie; Ramjist, Joel; Jivraj, Jamil; Farooq, Hamza; Sun, Cuiru; Yang, Victor X. D.
2015-03-01
Carotid atherosclerosis is a critical medical concern that can lead to ischemic stroke. Local hemodynamic patterns have also been associated with the development of atherosclerosis, particularly in regions with disturbed flow patterns such as bifurcations. Traditionally, this disease was treated using carotid endarterectomy, however recently there is an increasing trend of carotid artery stenting due to its minimally invasive nature. It is well known that this interventional technique creates changes in vasculature geometry and hemodynamic patterns due to the interaction of stent struts with arterial lumen, and is associated with complications such as distal emboli and restenosis. Currently, there is no standard imaging technique to evaluate regional hemodynamic patterns found in stented vessels. Doppler optical coherence tomography (DOCT) provides an opportunity to identify in vivo hemodynamic changes in vasculature using high-resolution imaging. In this study, blood flow profiles were examined at the bifurcation junction in the internal carotid artery (ICA) in a porcine model following stent deployment. Doppler imaging was further conducted using pulsatile flow in a phantom model, and then compared to computational fluid dynamics (CFD) simulation of a virtual bifurcation to assist with the interpretation of emphin vivo results.
Hypertext Interchange Using ICA.
ERIC Educational Resources Information Center
Rada, Roy; And Others
1995-01-01
Discusses extended ICA (Integrated Chameleon Architecture), a public domain toolset for generating text-to-hypertext translators. A system called SGML-MUCH has been developed using E-ICA (Extended Integrated Chameleon Architecture) and is presented as a case study with converters for the hypertext systems MUCH, Guide, Hyperties, and Toolbook.…
Han, M H; Sung, M W; Chang, K H; Min, Y G; Han, D H; Han, M C
1994-03-01
Traumatic pseudoaneurysm of the intracavernous internal carotid artery (ICA) is a very rare cause of epistaxis but is a life-threatening clinical situation when left untreated. The authors have experienced four cases of traumatic pseudoaneurysm involving the intracavernous ICA. Delayed massive epistaxes developed 1 to 8 months after trauma and initial transient epistaxis in all four patients. Three of the cases were successfully managed by the detachable balloon occlusion (DBO) of the ICA along with the aneurysm openings. In one case, a large pseudoaneurysm destroying a large area of the central skull base with peripheral blood clot was demonstrated on computed tomography, magnetic resonance imaging, and angiography; this patient died due to massive epistaxis before the trial of DBO. Imaging findings of pseudoaneurysms involving the intracavernous ICA in the four cases are described, and the role of endovascular treatment is discussed.
Chesbro, Steven B; Asongwed, Elmira T; Brown, Jamesha; John, Emmanuel B
2011-01-01
The purposes of this study were to: (1) identify the interrater and intrarater reliability of systolic blood pressures using a stethoscope and Doppler to determine an ankle-brachial index (ABI), and (2) to determine the correlation between the 2 methods. Peripheral arterial disease (PAD) affects approximately 8 to 12 million people in the United States, and nearly half of those with this disease are asymptomatic. Early detection and prompt treatment of PAD will improve health outcomes. It is important that clinicians perform tests that determine the presence of PAD. Two individual raters trained in ABI procedure measured the systolic blood pressures of 20 individuals' upper and lower extremities. Standard ABI measurement protocols were observed. Raters individually recorded the systolic blood pressures of each extremity using a stethoscope and a Doppler, for a total of 640 independent measures. Interrater reliability of Doppler measurements to determine SBP at the ankle was very strong (intraclass correlation coefficient [ICC], 0.93-0.99) compared to moderate to strong reliability using a stethoscope (ICC, 0.64-0.87). Agreement between the 2 devices to determine SBP was moderate to very weak (ICC, 0.13-0.61). Comparisons of the use of Doppler and stethoscope to determine ABI showed weak to very weak intrarater correlation (ICC, 0.17-0.35). Linear regression analysis of the 2 methods to determine ABI showed positive but weak to very weak correlations (r2 = .013, P = .184). A Doppler ultrasound is recommended over a stethoscope for accuracy in systolic pressure readings for ABI measurements.
A novel, microscope based, non invasive Laser Doppler flowmeter for choroidal blood flow assessment
Strohmaier, C; Werkmeister, RM; Bogner, B; Runge, C; Schroedl, F; Brandtner, H; Radner, W; Schmetterer, L; Kiel, JW; Grabnerand, G; Reitsamer, HA
2015-01-01
Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non invasive laser Doppler flowmeter (NILDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed PF4000). Linearity and stability of the NI-LDF were assessed in a silastic tubing model (i.d. 0.3 mm) at different flow rates (range 0.4 – 3 ml/h). In a rabbit model continuous choroidal blood flow measurements were performed with both instruments simultaneously. During blood flow measurements ocular perfusion pressure was changed by manipulations of intraocular pressure via intravitreal saline infusions. The NILDF measurement correlated linearly to intraluminal flow rates in the perfused tubing model (r = 0.99, p<0.05) and remained stable during a 1 hour measurement at a constant flow rate. Rabbit choroidal blood flow measured by the PF4000 and the NI-LDF linearly correlated with each other over the entire measurement range (r = 0.99, y = x* 1,01 – 12,35 P.U., p < 0,001). In conclusion, the NI-LDF provides valid, semi quantitative measurements of capillary blood flow in comparison to an established LDF instrument and is suitable for measurements at the posterior pole of the eye. PMID:21443871
Herlta, Catherine; Starka, Rosa; Sigmarsson, Haukur L; Kauffold, Johannes
2018-06-01
To test for the feasibility of transabdominal Doppler sonography (color, power, pulse wave) to define uterine perfusion characteristics throughout the estrous cycle in gilts. A total of 15 gilts were synchronized for estrus and scanned in their following spontaneous cycle while being restrained in a purpose-designed mobile crate. To define uterine perfusion characteristics, vessels in between and within uterine cross-sections were imaged and recorded as video sequences to be analyzed by PixelFlux® software for perfused area (Amix), blood flow velocity (vmix) and intensity (Imix) as well as resistance (RIvmix) and pulsatility index (PIvmix). Color Doppler sonography proved to be the only feasible technique, as it was less affected by animal movements than power and pulse wave sonography. As determined by color Doppler sonography, all five parameters determined showed specific patterns through the estrous cycle, i. e. Amix, vmix, Imix were high in proestrus, decreased in estrus and remained low in midestrus and most parts of diestrus; RIvmix and PIvmix with inversely paralleled patterns. This study has demonstrated that transabdominal color Doppler but not power and pulse wave Doppler sonography is feasible to be performed in crate-restrained gilts for studying uterine perfusion characteristics during the estrous cycle, and that changes of uterine perfusion over the course of the estrous cycle can be clearly followed by color Doppler sonography. Results encourage the use of color Doppler sonography for studying i. e. uterine capacity or uterus related infertility such as for cases of clinically unapparent endometritis. Schattauer GmbH.
A review of group ICA for fMRI data and ICA for joint inference of imaging, genetic, and ERP data
Calhoun, Vince D.; Liu, Jingyu; Adalı, Tülay
2009-01-01
Independent component analysis (ICA) has become an increasingly utilized approach for analyzing brain imaging data. In contrast to the widely used general linear model (GLM) that requires the user to parameterize the data (e.g. the brain's response to stimuli), ICA, by relying upon a general assumption of independence, allows the user to be agnostic regarding the exact form of the response. In addition, ICA is intrinsically a multivariate approach, and hence each component provides a grouping of brain activity into regions that share the same response pattern thus providing a natural measure of functional connectivity. There are a wide variety of ICA approaches that have been proposed, in this paper we focus upon two distinct methods. The first part of this paper reviews the use of ICA for making group inferences from fMRI data. We provide an overview of current approaches for utilizing ICA to make group inferences with a focus upon the group ICA approach implemented in the GIFT software. In the next part of this paper, we provide an overview of the use of ICA to combine or fuse multimodal data. ICA has proven particularly useful for data fusion of multiple tasks or data modalities such as single nucleotide polymorphism (SNP) data or event-related potentials. As demonstrated by a number of examples in this paper, ICA is a powerful and versatile data-driven approach for studying the brain. PMID:19059344
A review of group ICA for fMRI data and ICA for joint inference of imaging, genetic, and ERP data.
Calhoun, Vince D; Liu, Jingyu; Adali, Tülay
2009-03-01
Independent component analysis (ICA) has become an increasingly utilized approach for analyzing brain imaging data. In contrast to the widely used general linear model (GLM) that requires the user to parameterize the data (e.g. the brain's response to stimuli), ICA, by relying upon a general assumption of independence, allows the user to be agnostic regarding the exact form of the response. In addition, ICA is intrinsically a multivariate approach, and hence each component provides a grouping of brain activity into regions that share the same response pattern thus providing a natural measure of functional connectivity. There are a wide variety of ICA approaches that have been proposed, in this paper we focus upon two distinct methods. The first part of this paper reviews the use of ICA for making group inferences from fMRI data. We provide an overview of current approaches for utilizing ICA to make group inferences with a focus upon the group ICA approach implemented in the GIFT software. In the next part of this paper, we provide an overview of the use of ICA to combine or fuse multimodal data. ICA has proven particularly useful for data fusion of multiple tasks or data modalities such as single nucleotide polymorphism (SNP) data or event-related potentials. As demonstrated by a number of examples in this paper, ICA is a powerful and versatile data-driven approach for studying the brain.
A novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.
Strohmaier, C; Werkmeister, R M; Bogner, B; Runge, C; Schroedl, F; Brandtner, H; Radner, W; Schmetterer, L; Kiel, J W; Grabner, G; Reitsamer, H A
2011-06-01
Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non-invasive Laser Doppler Flowmeter (NI-LDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed PF4000). Linearity and stability of the NI-LDF were assessed in a silastic tubing model (i.d. 0.3 mm) at different flow rates (range 0.4-3 ml/h). In a rabbit model continuous choroidal blood flow measurements were performed with both instruments simultaneously. During blood flow measurements ocular perfusion pressure was changed by manipulations of intraocular pressure via intravitreal saline infusions. The NI-LDF measurement correlated linearly to intraluminal flow rates in the perfused tubing model (r = 0.99, p < 0.05) and remained stable during a 1 h measurement at a constant flow rate. Rabbit choroidal blood flow measured by the PF4000 and the NI-LDF linearly correlated with each other over the entire measurement range (r = 0.99, y = x∗1.01-12.35 P.U., p < 0.001). In conclusion, the NI-LDF provides valid, semi quantitative measurements of capillary blood flow in comparison to an established LDF instrument and is suitable for measurements at the posterior pole of the eye. Copyright © 2011 Elsevier Ltd. All rights reserved.
Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.
Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak
2012-06-01
Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the
Huang, Hanrui; Sejdić, Ervin
2013-12-01
Trans-cranial Doppler (TCD) recordings are used to monitor cerebral blood flow in the main cerebral arteries. The resting state is usually characterized by the mean velocity or the maximum Doppler shift frequency (an envelope signal) by insonating the middle cerebral arteries. In this study, we characterized cerebral blood flow in the anterior cerebral arteries. We analyzed both envelope signals and raw signals obtained from bilateral insonation. We recruited 20 healthy patients and conducted the data acquisition for 15 min. Features were extracted from the time domain, the frequency domain and the time-frequency domain. The results indicate that a gender-based statistical difference exists in the frequency and time-frequency domains. However, no handedness effect was found. In the time domain, information-theoretic features indicated that mutual dependence is higher in raw signals than in envelope signals. Finally, we concluded that insonation of the anterior cerebral arteries serves as a complement to middle cerebral artery studies. Additionally, investigation of the raw signals provided us with additional information that is not otherwise available from envelope signals. Use of direct trans-cranial Doppler raw data is therefore validated as a valuable method for characterizing the resting state. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Doppler optical coherence tomography of retinal circulation.
Tan, Ou; Wang, Yimin; Konduru, Ranjith K; Zhang, Xinbo; Sadda, SriniVas R; Huang, David
2012-09-18
Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R(2)>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the
Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R
2017-09-01
This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2 = 0.062) and TOI (r 2 = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.
Hemispheric Asymmetry of Visual Cortical Response by Means of Functional Transcranial Doppler
Roje-Bedeković, Marina; Lovrenčić-Huzjan, Arijana; Bosnar-Puretić, Marijana; Šerić, Vesna; Demarin, Vida
2012-01-01
We assessed the visual evoked response and investigated side-to-side differences in mean blood flow velocities (MBFVs) by means of functional transcranial Doppler (fTCD) in 49 right-handed patients with severe internal carotid artery (ICA) stenosis and 30 healthy volunteers, simultaneously in both posterior cerebral arteries (PCAs) using 2 MHz probes, successively in the dark and during the white light stimulation. Statistically significant correlation (P = 0.001) was shown in healthy and in patients (P < 0.05) between MBFV in right PCA in physiological conditions and MBFV in right PCA during the white light stimulation and in the dark. The correlation between MBVF in right PCA and contralateral left PCA was not statistically significant (P > 0.05). The correlation between ipsilateral left PCA was significantly higher than the one with contralateral right PCA (P < 0.05). There is a clear trend towards the lateralisation of the visual evoked response in the right PCA. PMID:22135771
Full-field high-speed laser Doppler imaging system for blood-flow measurements
NASA Astrophysics Data System (ADS)
Serov, Alexandre; Lasser, Theo
2006-02-01
We describe the design and performance of a new full-field high-speed laser Doppler imaging system developed for mapping and monitoring of blood flow in biological tissue. The total imaging time for 256x256 pixels region of interest is 1.2 seconds. An integrating CMOS image sensor is utilized to detect Doppler signal in a plurality of points simultaneously on the sample illuminated by a divergent laser beam of a uniform intensity profile. The integrating property of the detector improves the signal-to-noise ratio of the measurement, which results in high-quality flow-images provided by the system. The new technique is real-time, non-invasive and the instrument is easy to use. The wide range of applications is one of the major challenges for a future application of the imager. High-resolution high-speed laser Doppler perfusion imaging is a promising optical technique for diagnostic and assessing the treatment effect of the diseases such as e.g. atherosclerosis, psoriasis, diabetes, skin cancer, allergies, peripheral vascular diseases, skin irritancy and wound healing. We present some biological applications of the new imager and discuss the perspectives for the future implementations of the imager for clinical and physiological applications.
NASA Astrophysics Data System (ADS)
Kyoden, Tomoaki; Akiguchi, Shunsuke; Tajiri, Tomoki; Andoh, Tsugunobu; Hachiga, Tadashi
2017-11-01
The development of a system for in vivo visualization of occluded distal blood vessels for diabetic patients is the main target of our research. We herein describe two-beam multipoint laser Doppler velocimetry (MLDV), which measures the instantaneous multipoint flow velocity and can be used to observe the blood flow velocity in peripheral blood vessels. By including a motorized stage to shift the measurement points horizontally and in the depth direction while measuring the velocity, the path of the blood vessel in the skin could be observed using blood flow velocity in three-dimensional space. The relationship of the signal power density between the blood vessel and the surrounding tissues was shown and helped us identify the position of the blood vessel. Two-beam MLDV can be used to simultaneously determine the absolute blood flow velocity distribution and identify the blood vessel position in skin.
Parallel ICA and its hardware implementation in hyperspectral image analysis
NASA Astrophysics Data System (ADS)
Du, Hongtao; Qi, Hairong; Peterson, Gregory D.
2004-04-01
Advances in hyperspectral images have dramatically boosted remote sensing applications by providing abundant information using hundreds of contiguous spectral bands. However, the high volume of information also results in excessive computation burden. Since most materials have specific characteristics only at certain bands, a lot of these information is redundant. This property of hyperspectral images has motivated many researchers to study various dimensionality reduction algorithms, including Projection Pursuit (PP), Principal Component Analysis (PCA), wavelet transform, and Independent Component Analysis (ICA), where ICA is one of the most popular techniques. It searches for a linear or nonlinear transformation which minimizes the statistical dependence between spectral bands. Through this process, ICA can eliminate superfluous but retain practical information given only the observations of hyperspectral images. One hurdle of applying ICA in hyperspectral image (HSI) analysis, however, is its long computation time, especially for high volume hyperspectral data sets. Even the most efficient method, FastICA, is a very time-consuming process. In this paper, we present a parallel ICA (pICA) algorithm derived from FastICA. During the unmixing process, pICA divides the estimation of weight matrix into sub-processes which can be conducted in parallel on multiple processors. The decorrelation process is decomposed into the internal decorrelation and the external decorrelation, which perform weight vector decorrelations within individual processors and between cooperative processors, respectively. In order to further improve the performance of pICA, we seek hardware solutions in the implementation of pICA. Until now, there are very few hardware designs for ICA-related processes due to the complicated and iterant computation. This paper discusses capacity limitation of FPGA implementations for pICA in HSI analysis. A synthesis of Application-Specific Integrated Circuit
Trans-skull ultrasonic Doppler system aided by fuzzy logic
NASA Astrophysics Data System (ADS)
Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto
2012-06-01
This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.
Schwarzer, Patrik; Kuhn, Sven-Olaf; Stracke, Sylvia; Gründling, Matthias; Knigge, Stephan; Selleng, Sixten; Helm, Maximilian; Friesecke, Sigrun; Abel, Peter; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid
2015-09-08
Ionized calcium (iCa) concentration is often used in critical care and measured using blood gas analyzers at the point of care. Controlling and adjusting regional citrate anticoagulation (RCA) for continuous renal replacement therapy (CRRT) involves measuring the iCa concentration in two samples: systemic with physiological iCa concentrations and post filter samples with very low iCa concentrations. However, modern blood gas analyzers are optimized for physiological iCa concentrations which might make them less suitable for measuring low iCa in blood with a high concentration of citrate. We present results of iCa measurements from six different blood gas analyzers and the impact on clinical decisions based on the recommendations of the dialysis' device manufacturer. The iCa concentrations of systemic and post filter samples were measured using six distinct, frequently used blood gas analyzers. We obtained iCa results of 74 systemic and 84 post filter samples from patients undergoing RCA for CRRT at the University Medicine of Greifswald. The systemic samples showed concordant results on all analyzers with median iCa concentrations ranging from 1.07 to 1.16 mmol/L. The medians of iCa concentrations for post filter samples ranged from 0.21 to 0.50 mmol/L. Results of >70% of the post filter samples would lead to major differences in decisions regarding citrate flow depending on the instrument used. Measurements of iCa in post filter samples may give misleading information in monitoring the RCA. Recommendations of the dialysis manufacturer need to be revised. Meanwhile, little weight should be given to post filter iCa. Reference methods for low iCa in whole blood containing citrate should be established.
Prospects for in vivo blood velocimetry using acoustic resolution photoacoustic Doppler
NASA Astrophysics Data System (ADS)
Brunker, J.; Beard, P.
2016-03-01
Acoustic resolution photoacoustic Doppler flowmetry (AR-PAF) is a technique that has the potential to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Previous work has shown the potential of the technique using blood-mimicking phantoms, but it has proved difficult to make accurate measurements in blood, and thus in vivo application has not yet been possible. One explanation for this difficulty is that whole blood is insufficiently heterogeneous. Through experimental measurements in red blood cell suspensions of different concentrations, as well as in whole blood, we provide new insight and evidence that refutes this assertion. We show that the velocity measurement accuracy is influenced by bandlimiting not only due to the detector frequency response, but also due to spatial averaging of absorbers within the detector field-of-view. In addition, there is a detrimental effect of limited light penetration, but this can be mitigated by selecting less attenuated wavelengths of light, and also by employing range-gating signal processing. By careful choice of these parameters as well as the detector centre frequency, bandwidth and field-of-view, it is possible to make AR-PAF measurements in whole blood using transducers with bandwidths in the tens of MHz range. These findings have profound implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.
Lantsberg, L; Goldman, M
1990-01-01
In a retrospective study of critical ischaemia of the lower limb, sympathectomy appeared to be of value in the majority of patients. We therefore assessed sympathectomy by measuring skin blood flow before and after the procedure using laser Doppler flowmetry (LDF) and transcutaneous oxygen tension (TCpO2) techniques. Twenty patients underwent chemical sympathectomy and there was one surgical procedure. Measurements were performed before and 1 week after sympathectomy below the knee and on the forefoot. Symptomatic improvement occurred in 20 of 21 patients. This study demonstrates that skin blood flow in the leg and foot is improved by sympathectomy and confirms objectively our clinical impression.
NASA Astrophysics Data System (ADS)
Abiy, Lidet; Telischi, Fred; Parel, Jean-Marie A.; Manns, Fabrice; Saettele, Ralph; Morawski, Krzysztof; Ozdamar, Ozcan; Borgos, John; Delgado, Rafael; Miskiel, Edward; Yavuz, Erdem
2003-06-01
The aim of this project is the development of a microsurgical laser Doppler (LD) probe that simultaneously monitors blood flow and Electrocochleography (ECochG) from the round window of the ear. The device will prevent neurosensory hearing loss during acoustic neuroma surgery by preventing damage to the internal auditory nerve and to the cochlear blood flow supply. A commercially available 0.5 mm diameter Laser-Doppler velocimetry probe (LaserFlo, Vasamedics) was modified to integrate an ECochG electrode. A tube for suction and irrigation was incorporated into a sheath of the probe shaft, to facilitate cleaning of the round window (RW) and allow drug delivery to the round window membrane. The prototype microprobe was calibrated on a single vessel model and tested in vivo in a rabbit model. Preliminary results indicate that the microprobe was able to measure changes in cochlear blood flow (CBF) and ECochG potentials from the round window of rabbits in vivo. The microprobe is suitable for monitoring cochlear blood flow and auditory cochlear potentials during human surgery.
Jensen, Dennis M; Kovacs, Thomas O G; Ohning, Gordon V; Ghassemi, Kevin; Machicado, Gustavo A; Dulai, Gareth S; Sedarat, Alireza; Jutabha, Rome; Gornbein, Jeffrey
2017-05-01
For 4 decades, stigmata of recent hemorrhage in patients with nonvariceal lesions have been used for risk stratification and endoscopic hemostasis. The arterial blood flow that underlies the stigmata rarely is monitored, but can be used to determine risk for rebleeding. We performed a randomized controlled trial to determine whether Doppler endoscopic probe monitoring of blood flow improves risk stratification and outcomes in patients with severe nonvariceal upper gastrointestinal hemorrhage. In a single-blind study performed at 2 referral centers we assigned 148 patients with severe nonvariceal upper gastrointestinal bleeding (125 with ulcers, 19 with Dieulafoy's lesions, and 4 with Mallory Weiss tears) to groups that underwent standard, visually guided endoscopic hemostasis (control, n = 76), or endoscopic hemostasis assisted by Doppler monitoring of blood flow under the stigmata (n = 72). The primary outcome was the rate of rebleeding after 30 days; secondary outcomes were complications, death, and need for transfusions, surgery, or angiography. There was a significant difference in the rates of lesion rebleeding within 30 days of endoscopic hemostasis in the control group (26.3%) vs the Doppler group (11.1%) (P = .0214). The odds ratio for rebleeding with Doppler monitoring was 0.35 (95% confidence interval, 0.143-0.8565) and the number needed to treat was 7. In a randomized controlled trial of patients with severe upper gastrointestinal hemorrhage from ulcers or other lesions, Doppler probe guided endoscopic hemostasis significantly reduced 30-day rates of rebleeding compared with standard, visually guided hemostasis. Guidelines for nonvariceal gastrointestinal bleeding should incorporate these results. ClinicalTrials.gov no: NCT00732212 (CLIN-013-07F). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Glasser, Matthew F; Coalson, Timothy S; Bijsterbosch, Janine D; Harrison, Samuel J; Harms, Michael P; Anticevic, Alan; Van Essen, David C; Smith, Stephen M
2018-06-02
Temporal fluctuations in functional Magnetic Resonance Imaging (fMRI) have been profitably used to study brain activity and connectivity for over two decades. Unfortunately, fMRI data also contain structured temporal "noise" from a variety of sources, including subject motion, subject physiology, and the MRI equipment. Recently, methods have been developed to automatically and selectively remove spatially specific structured noise from fMRI data using spatial Independent Components Analysis (ICA) and machine learning classifiers. Spatial ICA is particularly effective at removing spatially specific structured noise from high temporal and spatial resolution fMRI data of the type acquired by the Human Connectome Project and similar studies. However, spatial ICA is mathematically, by design, unable to separate spatially widespread "global" structured noise from fMRI data (e.g., blood flow modulations from subject respiration). No methods currently exist to selectively and completely remove global structured noise while retaining the global signal from neural activity. This has left the field in a quandary-to do or not to do global signal regression-given that both choices have substantial downsides. Here we show that temporal ICA can selectively segregate and remove global structured noise while retaining global neural signal in both task-based and resting state fMRI data. We compare the results before and after temporal ICA cleanup to those from global signal regression and show that temporal ICA cleanup removes the global positive biases caused by global physiological noise without inducing the network-specific negative biases of global signal regression. We believe that temporal ICA cleanup provides a "best of both worlds" solution to the global signal and global noise dilemma and that temporal ICA itself unlocks interesting neurobiological insights from fMRI data. Copyright © 2018 Elsevier Inc. All rights reserved.
Mues, Adam C; Okhunov, Zhamshid; Badani, Ketan; Gupta, Mantu; Landman, Jaime
2010-12-01
Hemostasis remains a major challenge associated with laparoscopic renal surgery. We evaluated a cost-effective novel Doppler probe (DP) for assessment of vascular control during laparoscopic partial nephrectomy (LPN). We prospectively collected data during LPN procedures. We documented tumor location and size as well as subjective quality of the hilar dissection. The DP was compared with our standard intraoperative ultrasound system (SUS) for the ability to detect blood flow during hilar dissection and to determine parenchymal ischemia around the tumor after clamping of the renal vessels. Twenty patients underwent LPN by a single surgeon. The mean tumor size was 3.0 cm (range: 1.2-6.3 cm). The times to assess the kidney using the SUS and DP were 68.6 seconds (range: 20-155) and 44.5 seconds (range: 15-180), respectively. Evaluation prior to renal hilar clamping demonstrated the presence of blood flow in all 20 patients (100%) using the SUS and in 17 of 20 (85%) using the DP. Similarly, cessation of blood flow with clamping was documented in 100% of cases with SUS and 85% with DP. Persistent flow was detected by both SUS and DP in two patients requiring further dissection and reclamping. Then, both systems detected the absence of flow before tumor resection. With blood flow interruption confirmation, no patient had significant bleeding at the time of renal parenchymal transection. Intraoperative Doppler ultrasound technologies minimize the risk of significant bleeding during LPN. The DP is a small, simple, effective probe that can be used to assess blood flow interruption to the kidney during laparoscopic renal surgery.
Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping
2016-01-01
Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement. PMID:26977365
Qi, Li; Zhu, Jiang; Hancock, Aneeka M; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D; Chen, Zhongping
2016-02-01
Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement.
Grzesiak, Mariusz; Hincz, Piotr; Forys, Sebastian; Ahmed, Rehana B; Wilczynski, Jan
2013-01-01
The aims were to investigate whether any changes in placental and fetal circulation were observed during fenoterol tocolysis within the first 48 hours of therapy. Doppler evaluation of placental and fetal circulation was performed prior to fenoterol administration and then after 24 and 48 hours. Maternal heart rate and pulsatility index (PI) in uterine arteries were assessed. FHR, RI and PI of umbilical artery and middle cerebral artery were measured. E/A ratio for A-V valves, the myocardial performance index (MPI) and shortening fraction (SF) were calculated for both ventricles independently. The blood flow pattern in DV was assessed using PI, S/a ratio and peak velocity index for the vein. To determine changes over time in all study variable analysis of variance (ANOVA) for repeated measurements followed by Tukey-Kramer's multiple comparison test was used. The effects of additional clinical covariates were checked. Uterine and fetal arterial blood flow patterns were not altered significantly during 48 hours of tocolysis. No significant changes were observed in fetal cardiac function parameters as well. The evaluation of Doppler parameters in the DV revealed a significant increase in PVIV after 48 hours. Additionally after 48 hours of successful tocolysis S/a ratio values were significantly lower. Short term intravenous administration of fenoterol seems not to alter uterine and fetal arterial blood flow pattern. Direct fetal cardiac function remained unaffected. However significant changes of selected Doppler parameters in DV may suggest further studies should be performed to assess more precisely fetal venous blood flow.
Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M
1999-06-01
Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p = 0.001) during and an increase (p = 0.001) after foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.
NASA Astrophysics Data System (ADS)
Yazdanfar, Siavash; Kulkarni, Manish D.; Wong, Richard C. K.; Sivak, Michael J., Jr.; Willis, Joseph; Barton, Jennifer K.; Welch, Ashley J.; Izatt, Joseph A.
1998-04-01
A recently developed modality for blood flow measurement holds high promise in the management of bleeding ulcers. Color Doppler optical coherence tomography (CDOCT) uses low- coherence interferometry and digital signal processing to obtain precise localization of tissue microstructure simultaneous with bi-directional quantitation of blood flow. We discuss CDOCT as a diagnostic tool in the management of bleeding gastrointestinal lesions. Common treatments for bleeding ulcers include local injection of a vasoconstrictor, coagulation of blood via thermal contact or laser treatment, and necrosis of surrounding tissue with a sclerosant. We implemented these procedures in a rat dorsal skin flap model, and acquired CDOCT images before and after treatment. In these studies, CDOCT succeeded in identifying cessation of flow before it could be determined visually. Hence, we demonstrate the diagnostic capabilities of CDOCT in the regulation of bleeding in micron-scale vessels.
Laser Doppler diagnostics for orthodontia
NASA Astrophysics Data System (ADS)
Ryzhkova, Anastasia V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Kharish, Natalia A.
2004-06-01
The results of statistical analysis of Doppler spectra of intensity fluctuations of light, scattered from mucous membrane of oral cavity of healthy volunteers and patients, abused by the orthodontic diseases, are presented. Analysis of Doppler spectra, obtained from tooth pulp of patients, is carried out. New approach to monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of Doppler measuring system on formation of the output signal is studied.
The ICA Communication Audit: Rationale and Development.
ERIC Educational Resources Information Center
Goldhaber, Gerald M.
After reviewing previous research on communication in organizations, the Organizational Communication Division of the International Communication Association (ICA) decided, in 1971, to develop its own measurement system, the ICA Communication Audit. Rigorous pilot-testing, refinement, standardization, and application would allow the construction…
NASA Astrophysics Data System (ADS)
Yang, Victor X. D.; Gordon, Maggie L.; Tang, Shou-Jiang; Marcon, Norman E.; Gardiner, Geoffrey; Qi, Bing; Bisland, Stuart; Seng-Yue, Emily; Lo, Stewart; Pekar, Julius; Wilson, Brian C.; Vitkin, I. Alex
2003-09-01
We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomography (EDOCT) imaging in normal rat and human esophagus. Microvascular flow in blood vessels less than 100 µm diameter was detected using a combination of color-Doppler and velocity variance imaging modes, during clinical endoscopy using a mobile EDOCT system.
Quantitative imaging of red blood cell velocity invivo using optical coherence Doppler tomography
NASA Astrophysics Data System (ADS)
Ren, Hugang; Du, Congwu; Park, Kicheon; Volkow, Nora D.; Pan, Yingtian
2012-06-01
We present particle counting ultrahigh-resolution optical Doppler tomography (pc-μODT) that enables accurate imaging of red blood cell velocities (νRBC) of cerebrovascular networks by detecting the Doppler phase transients induced by the passage of a RBC through a capillary. We apply pc-μODT to image the response of capillary νRBC to mild hypercapnia in mouse cortex. The results show that νRBC in normocapnia (νN = 0.72 ± 0.15 mm/s) increased 36.1% ± 5.3% (νH = 0.98 ± 0.29 mm/s) in response to hypercapnia. Due to uncorrected angle effect and low hematocrit (e.g., ˜10%), νRBC directly measured by μODT were markedly underestimated (νN ≈ 0.27 ± 0.03 mm/s, νH ≈ 0.37± 0.05 mm/s). Nevertheless, the measured νRBC increase (35.3%) matched that (36.1% ± 5.3%) by pc-μODT.
Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen
2011-01-01
We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography. PMID:21941690
Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen
2011-01-01
We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.
Staggered Multiple-PRF Ultrafast Color Doppler.
Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien
2016-06-01
Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.
Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita
2018-04-01
To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.
Jensen, Dennis M.; Ohning, Gordon V.; Kovacs, Thomas O.G.; Jutabha, Rome; Ghassemi, Kevin; Dulai, Gareth S.; Machicado, Gustavo A.
2015-01-01
BACKGROUND AND AIMS Few prospective reports describe the short term natural history of colon diverticular hemorrhage based upon stigmata of recent hemorrhage and none include blood flow detection for risk stratification or as a guide to definitive hemostasis. Our purposes are to report the 30 day natural history of definitive diverticular hemorrhage based upon stigmata and to describe Doppler probe blood flow detection and as a guide to definitive hemostasis. METHODS Different cohorts of patients with severe diverticular bleeding and stigmata on urgent colonoscopy are reported. For 30 day natural history, patients were treated medically. If severe rebleeding occurred, they had surgical or angiographic treatment. Natural history with major stigmata (active bleeding, visible vessel, or adherent clot) and no stigmata or flat spots after washing away clots are reported. Doppler probe detection of arterial blood flow underneath stigmata before and after hemostasis is also reported in a recent cohort. RESULTS For natural history patients with major stigmata treated medically had 65.8% (25/38) rebleeding rates and 44.7% (17/38) had intervention for hemostasis. Patients with spots or clean bases had no rebleeding. Doppler probe detected arterial blood flow in 92% of major stigmata, none after hemostasis and no one rebled. CONCLUSIONS 1. Patients with major stigmata treated medically had high rates of rebleeding and intervention for hemostasis. 2. Patients with clean diverticula or only flat spots had no rebleeding. 3. High rates of arterial blood flow were detected under major stigmata with Doppler probe but with obliteration by hemostasis no rebleeding occurred. PMID:26227931
ICA model order selection of task co-activation networks.
Ray, Kimberly L; McKay, D Reese; Fox, Peter M; Riedel, Michael C; Uecker, Angela M; Beckmann, Christian F; Smith, Stephen M; Fox, Peter T; Laird, Angela R
2013-01-01
Independent component analysis (ICA) has become a widely used method for extracting functional networks in the brain during rest and task. Historically, preferred ICA dimensionality has widely varied within the neuroimaging community, but typically varies between 20 and 100 components. This can be problematic when comparing results across multiple studies because of the impact ICA dimensionality has on the topology of its resultant components. Recent studies have demonstrated that ICA can be applied to peak activation coordinates archived in a large neuroimaging database (i.e., BrainMap Database) to yield whole-brain task-based co-activation networks. A strength of applying ICA to BrainMap data is that the vast amount of metadata in BrainMap can be used to quantitatively assess tasks and cognitive processes contributing to each component. In this study, we investigated the effect of model order on the distribution of functional properties across networks as a method for identifying the most informative decompositions of BrainMap-based ICA components. Our findings suggest dimensionality of 20 for low model order ICA to examine large-scale brain networks, and dimensionality of 70 to provide insight into how large-scale networks fractionate into sub-networks. We also provide a functional and organizational assessment of visual, motor, emotion, and interoceptive task co-activation networks as they fractionate from low to high model-orders.
ICA model order selection of task co-activation networks
Ray, Kimberly L.; McKay, D. Reese; Fox, Peter M.; Riedel, Michael C.; Uecker, Angela M.; Beckmann, Christian F.; Smith, Stephen M.; Fox, Peter T.; Laird, Angela R.
2013-01-01
Independent component analysis (ICA) has become a widely used method for extracting functional networks in the brain during rest and task. Historically, preferred ICA dimensionality has widely varied within the neuroimaging community, but typically varies between 20 and 100 components. This can be problematic when comparing results across multiple studies because of the impact ICA dimensionality has on the topology of its resultant components. Recent studies have demonstrated that ICA can be applied to peak activation coordinates archived in a large neuroimaging database (i.e., BrainMap Database) to yield whole-brain task-based co-activation networks. A strength of applying ICA to BrainMap data is that the vast amount of metadata in BrainMap can be used to quantitatively assess tasks and cognitive processes contributing to each component. In this study, we investigated the effect of model order on the distribution of functional properties across networks as a method for identifying the most informative decompositions of BrainMap-based ICA components. Our findings suggest dimensionality of 20 for low model order ICA to examine large-scale brain networks, and dimensionality of 70 to provide insight into how large-scale networks fractionate into sub-networks. We also provide a functional and organizational assessment of visual, motor, emotion, and interoceptive task co-activation networks as they fractionate from low to high model-orders. PMID:24339802
NASA Astrophysics Data System (ADS)
Werkmeister, René M.; Vietauer, Martin; Knopf, Corinna; Fürnsinn, Clemens; Leitgeb, Rainer A.; Reitsamer, Herbert; Gröschl, Martin; Garhöfer, Gerhard; Vilser, Walthard; Schmetterer, Leopold
2014-10-01
A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in the rat using a new optical system that combines the measurement of blood flow velocities via Doppler Fourier-domain optical coherence tomography and the measurement of vessel diameters using a fundus camera-based technique. Relying on fundus images for extraction of retinal vessel diameters instead of OCT images improves the reliability of the technique. The system was operated with an 841-nm superluminescent diode and a charge-coupled device camera that could be operated at a line rate of 20 kHz. We show that the system is capable of quantifying the response of 100% oxygen breathing on the retinal blood flow. In six rats, we observed a decrease in retinal vessel diameters of 13.2% and a decrease in retinal blood velocity of 42.6%, leading to a decrease in retinal blood flow of 56.7%. Furthermore, in four rats, the response of retinal blood flow during stimulation with diffuse flicker light was assessed. Retinal vessel diameter and blood velocity increased by 3.4% and 28.1%, respectively, leading to a relative increase in blood flow of 36.2%;. The presented technique shows much promise to quantify early changes in retinal blood flow during provocation with various stimuli in rodent models of ocular diseases in rats.
Pinotti, M; Paone, N
1996-06-01
A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage.
CUDAICA: GPU Optimization of Infomax-ICA EEG Analysis
Raimondo, Federico; Kamienkowski, Juan E.; Sigman, Mariano; Fernandez Slezak, Diego
2012-01-01
In recent years, Independent Component Analysis (ICA) has become a standard to identify relevant dimensions of the data in neuroscience. ICA is a very reliable method to analyze data but it is, computationally, very costly. The use of ICA for online analysis of the data, used in brain computing interfaces, results are almost completely prohibitive. We show an increase with almost no cost (a rapid video card) of speed of ICA by about 25 fold. The EEG data, which is a repetition of many independent signals in multiple channels, is very suitable for processing using the vector processors included in the graphical units. We profiled the implementation of this algorithm and detected two main types of operations responsible of the processing bottleneck and taking almost 80% of computing time: vector-matrix and matrix-matrix multiplications. By replacing function calls to basic linear algebra functions to the standard CUBLAS routines provided by GPU manufacturers, it does not increase performance due to CUDA kernel launch overhead. Instead, we developed a GPU-based solution that, comparing with the original BLAS and CUBLAS versions, obtains a 25x increase of performance for the ICA calculation. PMID:22811699
[Microcirculatory blood and lymph flow examination in eyelid skin by laser Doppler flowmetry].
Safonova, T N; Kintyukhina, N P; Sidorov, V V; Gladkova, O V; Reyn, E S
to study normal blood and lymph microcirculation of the upper and lower eyelids in different age groups. The study included 108 volunteers (216 eyes) aged from 20 to 80 years with no signs of changes in anterior segment structures, who were grouped by age ranges (20-30 years, 31-40 years, 41-50 years, 51-60 years, 61-70 years, and 71-80 years) into 6 groups equal in gender and quantitative composition. In all volunteers, microcirculation of the upper and lower eyelids was examined by laser Doppler flowmetry (LDF) ('LASMA MC-1' peripheral blood and lymph flow analyzer and 'LASMA MC' laser diagnostic complex, LASMA LLC). The average perfusion changes in blood and lymph flow as well as blood and lymph flow oscillations were analyzed. Blood and lymph flow in the microvasculature of the upper and lower eyelids is variable and depends on neither the age, nor gender of the test subject. On LDF-gram, every increase in amplitude of blood flow corresponds to a decrease in that of lymph flow. The non-invasive method of LDF expands our diagnostic capabilities as it enables assessment of not only blood, but also lymph flow. The data obtained can serve as a starting point for exploring microcirculation in different age groups in the presence of different pathological processes.
Zeng, S; Zhou, J; Peng, Q; Tian, L; Xu, G; Zhao, Y; Wang, T; Zhou, Q
2015-06-01
To use three-dimensional (3D) power Doppler ultrasound to investigate cerebral blood flow perfusion in fetuses with congenital heart disease (CHD). The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) in the total intracranial volume and the main arterial territories (middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA)) were evaluated prospectively and compared in 112 fetuses with CHD and 112 normal fetuses using 3D power Doppler. Correlations between the 3D power Doppler indices and neurodevelopment scores at 12 months of age were assessed in a subset of the CHD group, and values were compared with those of controls. Compared with the controls, the VI, FI and VFI of the total intracranial volume and the three main arteries were significantly higher in fetuses with hypoplastic left heart syndrome and left-sided obstructive lesions (P < 0.001), and the 3D power Doppler values in the ACA territory were significantly higher in fetuses with transposition of the great arteries (P < 0.01). The largest proportional increase in the blood flow perfusion indices in the fetuses with CHD relative to controls was observed in the ACA territory (P < 0.05). Among 41 cases with CHD that underwent testing, the mean Psychomotor Development Index (PDI) and Mental Development Index (MDI) scores were significantly lower than in 94 of the controls that were tested (P < 0.001). Among these CHD cases, total intracranial FI was positively correlated with PDI (r = 0.342, P = 0.029) and MDI (r = 0.339, P = 0.030), and ACA-VI and ACA-VFI were positively correlated with PDI (r = 0.377 and 0.389, P = 0.015 and 0.012, respectively) but were not correlated with MDI (r = 0.243 and 0.203, P = 0.126 and 0.204, respectively). Cerebral blood flow perfusion was increased relative to controls in most fetuses with CHD and was associated with neurodevelopment scores at 12 months
Pinotti, Marcos; Paone, Nicola
1996-05-01
A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage. © 1996 International Society for Artificial Organs.
Real-Time Color-Doppler Guidance of HIFU for the Selective Avoidance or Occlusion of Blood Vessels
NASA Astrophysics Data System (ADS)
Rabkin, Brian A.; Zderic, Vesna; Vaezy, Shahram
2005-03-01
High-intensity focused ultrasound (HIFU) has been shown to effectively occlude blood vessels deep within tissue. The objective of the current study was to synchronize HIFU and color-Doppler ultrasound (US) for the real-time visualization of flow within blood vessels during HIFU treatment. The excitation of the HIFU was synchronized with the color-Doppler imager by collecting the excitation pulses of one of the elements of either a curved array intracavitary (C 9-5) or an intraoperative (CL 10-5) imaging probe. The collected excitation pulse was converted into a TTL-high pulse, which was delayed and gated to time the excitation duration and location of the HIFU pulse with respect to each imaging frame. The single pulse was used to drive a 3.2 MHz concave HIFU transducer (focal length of 3.5 cm, f-number 1) while the US imager was not collecting RF signals from the treatment region of the US image. The feasibility of the system was demonstrated in vivo by the selective ablation of tissue adjacent to, or the occlusion of, large vessels (including the femoral artery) both transcutaneously and interoperatively in the rabbit and pig. For the occlusion of vessels, the HIFU focus was placed immediately distal (with respect to the transducer) to the vessel at a depth of 2-2.5 cm. HIFU was applied at in situ intensities of 1000-2000 W/cm2, at a duty cycle of 50-75%, and a HIFU pulse repetition frequency (set by the US image frame rate) of 6-18 Hz. During each HIFU exposure, the HIFU pulse resulted in color interference bands running vertically within the color-Doppler window. Through the synchronization of the US imager with the HIFU excitation, the location and duration of the interference bands were set outside the treatment region within each image frame. This provided the operator with a clear view of the HIFU treatment site during therapy. Gross assessment showed necrosis of the tissue surrounding the HIFU treated vessel and occlusion of vessels up to 4 mm in diameter
An ICA based MIMO-OFDM VLC scheme
NASA Astrophysics Data System (ADS)
Jiang, Fangqing; Deng, Honggui; Xiao, Wei; Tao, Shaohua; Zhu, Kaicheng
2015-07-01
In this paper, we propose a novel ICA based MIMO-OFDM VLC scheme, where ICA is applied to convert the MIMO-OFDM channel into several SISO-OFDM channels to reduce computational complexity in channel estimation, without any spectral overhead. Besides, the FM is first investigated to further modulate the OFDM symbols to eliminate the correlation of the signals, so as to improve the separation performance of the ICA algorithm. In the 4×4MIMO-OFDM VLC simulation experiment, LOS path and NLOS paths are both considered, each transmitting signal at 100 Mb/s. Simulation results show that the BER of the proposed scheme reaches the 10-5 level at SNR=20 dB, which is a large improvement compared to the traditional schemes.
Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat
2015-04-01
To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p < 0.05). 3-D ovarian volumes were found significantly higher in patients with PCOS (p < 0.05), and a negative correlation was also obtained between ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.
Temporal enhancement of two-dimensional color doppler echocardiography
NASA Astrophysics Data System (ADS)
Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.
2016-03-01
Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.
Käser, S. A.; Glauser, P. M.; Maurer, C. A.
2012-01-01
Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968
Keegan, Jennifer; Raphael, Claire E; Parker, Kim; Simpson, Robin M; Strain, Stephen; de Silva, Ranil; Di Mario, Carlo; Collinson, Julian; Stables, Rod H; Wage, Ricardo; Drivas, Peter; Sugathapala, Malindie; Prasad, Sanjay K; Firmin, David N
2015-10-02
Temporal patterns of coronary blood flow velocity can provide important information on disease state and are currently assessed invasively using a Doppler guidewire. A non-invasive alternative would be beneficial as it would allow study of a wider patient population and serial scanning. A retrospectively-gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) was developed at 3 Tesla. Velocity maps were acquired in 8 proximal right and 15 proximal left coronary arteries of 18 subjects who had previously had a Doppler guidewire study at the time of coronary angiography. Cardiovascular magnetic resonance (CMR) velocity-time curves were processed semi-automatically and compared with corresponding invasive Doppler data. When corrected for differences in heart rate between the two studies, CMR mean velocity through the cardiac cycle, peak systolic velocity (PSV) and peak diastolic velocity (PDV) were approximately 40 % of the peak Doppler values with a moderate - good linear relationship between the two techniques (R(2): 0.57, 0.64 and 0.79 respectively). CMR values of PDV/PSV showed a strong linear relationship with Doppler values with a slope close to unity (0.89 and 0.90 for right and left arteries respectively). In individual vessels, plots of CMR velocities at all cardiac phases against corresponding Doppler velocities showed a consistent linear relationship between the two with high R(2) values (mean +/-SD: 0.79 +/-.13). High temporal resolution breath-hold spiral phase velocity mapping underestimates absolute values of coronary flow velocity but allows accurate assessment of the temporal patterns of blood flow.
Nukumizu, Yoshihito; Matsushita, Masahiro; Sakurai, Tsunehisa; Kobayashi, Masayoshi; Nishikimi, Naomichi; Komori, Kimihiro
2007-01-01
To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.
Kıvanç, Sertaç Argun; Kıvanç, Merih; Kılıç, Volkan; Güllülü, Gülay; Özmen, Ahmet Tuncer
2017-04-01
To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before. Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy. Mean bacterial counts on the IOLs were 7.1±0.4 log 10 CFU/mL with the ICA+ isolate, and 6.7±0.8 log 10 CFU/mL with the ICA- isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p=0.009 and p=0.013). The highest biofilm production was obtained on IOL C (PMMA) (p<0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p<0.001). Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study.
Ogasawara, Kuniaki; Inoue, Takashi; Kobayashi, Masakazu; Endo, Hidehoko; Yoshida, Kenji; Fukuda, Takeshi; Terasaki, Kazunori; Ogawa, Akira
2005-02-01
Cerebral hyperperfusion syndrome is a rare but serious complication of carotid endarterectomy (CEA). The aim of the present study was to determine whether intraoperative blood flow velocity (BFV) monitoring in the middle cerebral artery (MCA) by using transcranial Doppler ultrasonography (TCD) could be used as a reliable technique to detect cerebral hyperperfusion following CEA by comparing findings with those of brain single photon emission CT (SPECT). Intraoperative BFV monitoring was attempted in 67 patients undergoing CEA for treatment of ipsilateral internal carotid artery (ICA) stenosis (> or =70%). Cerebral blood flow (CBF) was also assessed using SPECT, which was performed before and immediately after CEA. Intraoperative BFV monitoring was achieved in 60 patients. Of the 60 patients, post-CEA hyperperfusion (CBF increase > or =100%, compared with preoperative values) was observed in six patients. The sensitivity, specificity, and positive predictive value of the BFV increases immediately after declamping of the ICA for detecting post-CEA hyperperfusion was 100%, 94% and 67%, respectively, with a cut-off point 2.0-fold that of preclamping BFV. The sensitivity and specificity of the BFV increases at the end of the procedure for detecting post-CEA hyperperfusion were 100% for both parameters, with cut-off points of 2.0- to 2.2-fold BFV of preclamping value. Hyperperfusion syndrome developed in two patients with post-CEA hyperperfusion, but intracerebral hemorrhage did not occur. In one of these two patients, BFV monitoring was not possible because of failure to obtain an adequate bone window. Intraoperative MCA BFV monitoring by using TCD is a less reliable method to detect cerebral hyperperfusion following CEA than postoperative MCA BFV monitoring, provided adequate monitoring can be achieved.
Lim, Gye-Yeon; Im, Soo Ah; Jung, Won Sang; Lee, Jae Mun; Lee, Ah Won
2005-09-01
The aim of this prospective study was to evaluate the diagnostic value of power Doppler ultrasonography (PDUS) and contrast-enhanced PDUS (CEPDUS) in the depiction and characterization of experimentally induced arthritis in the rabbit. Thirty rabbits were divided into three groups consisting of one control group (saline injection group) and two experimental groups: a suppurative arthritis group and a chemically induced synovitis group. The same amount (1 ml) of each agent was directly injected into the right hip joint. Serial color Doppler ultrasound (CDUS), PDUS, and CEPDUS images were obtained before and after injection. We observed that all of the infected knees in the suppurative arthritis group with Staphylococcus aureus demonstrated an increased signal on PDUS after inoculation. A minimal power Doppler signal was presented in the chemically induced synovitis group with talc injection, but none of the control knees demonstrated any increased signals. CEPDUS was the most sensitive imaging modality for evaluating the increase of blood flows in suppurative arthritis and was subsequently followed by PDUS and CDUS. The increased signals obtained with PDUS represent increased local blood flows; therefore, this technique can be used for evaluating the degree of inflammation. Furthermore, using the contrast agent enhances the sensitivity of PDUS, and it can even be useful for differentiating borderline cases. Copyright 2005 Wiley Periodicals, Inc
Sato, Kohei; Sadamoto, Tomoko; Hirasawa, Ai; Oue, Anna; Subudhi, Andrew W; Miyazawa, Taiki; Ogoh, Shigehiko
2012-01-01
Arterial CO2 serves as a mediator of cerebral blood flow (CBF), and its relative influence on the regulation of CBF is defined as cerebral CO2 reactivity. Our previous studies have demonstrated that there are differences in CBF responses to physiological stimuli (i.e. dynamic exercise and orthostatic stress) between arteries in humans. These findings suggest that dynamic CBF regulation and cerebral CO2 reactivity may be different in the anterior and posterior cerebral circulation. The aim of this study was to identify cerebral CO2 reactivity by measuring blood flow and examine potential differences in CO2 reactivity between the internal carotid artery (ICA), external carotid artery (ECA) and vertebral artery (VA). In 10 healthy young subjects, we evaluated the ICA, ECA, and VA blood flow responses by duplex ultrasonography (Vivid-e, GE Healthcare), and mean blood flow velocity in middle cerebral artery (MCA) and basilar artery (BA) by transcranial Doppler (Vivid-7, GE healthcare) during two levels of hypercapnia (3% and 6% CO2), normocapnia and hypocapnia to estimate CO2 reactivity. To characterize cerebrovascular reactivity to CO2, we used both exponential and linear regression analysis between CBF and estimated partial pressure of arterial CO2, calculated by end-tidal partial pressure of CO2. CO2 reactivity in VA was significantly lower than in ICA (coefficient of exponential regression 0.021 ± 0.008 vs. 0.030 ± 0.008; slope of linear regression 2.11 ± 0.84 vs. 3.18 ± 1.09% mmHg−1: VA vs. ICA, P < 0.01). Lower CO2 reactivity in the posterior cerebral circulation was persistent in distal intracranial arteries (exponent 0.023 ± 0.006 vs. 0.037 ± 0.009; linear 2.29 ± 0.56 vs. 3.31 ± 0.87% mmHg−1: BA vs. MCA). In contrast, CO2 reactivity in ECA was markedly lower than in the intra-cerebral circulation (exponent 0.006 ± 0.007; linear 0.63 ± 0.64% mmHg−1, P < 0.01). These findings indicate that vertebro-basilar circulation has lower CO2 reactivity than
Laser Doppler assessment of skin blood flow in arteriopathic limbs.
Allen, P I; Goldman, M
1987-05-01
In severely ischaemic lower limbs, the skin response to changing posture from lying to standing is a diagnostic flush. We investigated this observation by measurements of the microcirculation using the non-invasive laser Doppler technique. Eleven patients with ankle: brachial pressure (A:B) ratios less than 0.7 were compared with 13 age-matched controls (A:B ratios greater than 1). In normal subjects, mean horizontal skin blood flow (SBF) was 30.2 +/- 14.9 (+/- SD), significantly greater than mean SBF in the ischaemic group: 12.4 +/- 9.2 (P less than 0.01, Student's t test). Mean SBF fell in the normal group on dependency to 27.5 +/- 16.4 but this change was not significant. Unexpectedly mean SBF rose in the ischaemic limbs to 20.7 +/- 13.8 (P less than 0.05). The pattern of SBF response to change in posture is different in normal and arteriopathic limbs.
Iwasaki, Wataru; Nogami, Hirofumi; Takeuchi, Satoshi; Furue, Masutaka; Higurashi, Eiji; Sawada, Renshi
2015-10-05
Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.
NASA Astrophysics Data System (ADS)
Tan, Ou; Liu, Gangjun; Liang, Liu; Gao, Simon S.; Pechauer, Alex D.; Jia, Yali; Huang, David
2015-06-01
An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans (2×2 mm) obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was 45.4±6.7 μl/min for healthy control and 34.7±7.6 μl/min for glaucomatous participants (p-value=0.01). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement.
Jung, Ho-Jung; Jung, Hwanseok; Lee, Taeyoung; Kim, Jongho; Park, Jongsin; Kim, Hacsoo; Cho, Junghwan; Lee, Won-Young; Park, Sung-Woo; Rhee, Eun-Jung; Oh, Hyung-Geun
2017-01-01
Intracranial arterial stenosis (ICAS) is a common cause of ischemic stroke in Asians. Decreased muscle mass is one of the major causes of chronic disease in adults. The purpose of this study was to analyze the relationship between muscle mass and ICAS in Korean adults. For this study, we selected a total of 10,530 participants (mean age, 43.3 years; 8558 men) in a health screening program, for whom transcranial Doppler (TCD) ultrasound was used to detect >50% ICAS based on criteria modified from the stroke outcomes and neuroimaging of intracranial atherosclerosis trial. Body composition was evaluated by bioelectrical impedance analysis (BIA). Skeletal muscle index (SMI) was calculated with muscle mass/weight (kg) * 100. Among the total patient population, 322 (3.1%) subjects had ICAS. Subjects with ICAS were older, and had higher mean values for fasting glucose, body mass index and blood pressure compared with those without ICAS. Subjects with ICAS had significantly lower muscle mass, SMI and higher percent body fat compared with those without ICAS. In logistic regression analysis, the subjects in the highest tertile of muscle mass had the lowest odds ratio for ICAS with the lowest tertile group of muscle mass as the reference group even after adjusting for age, systolic blood pressure, fasting blood glucose, sex, smoking and exercise (OR 0.650, 95% CI 0.442-0.955). Subjects with ICAS had significantly decreased muscle mass compared with those without ICAS in Korean adults. The risk for ICAS was lower in subjects with higher muscle mass. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
von Wowern, Emma; Olofsson, Per
2018-09-01
Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.
Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.
Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph
2017-01-01
Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.
Single-trial event-related potential extraction through one-unit ICA-with-reference.
Lee, Wee Lih; Tan, Tele; Falkmer, Torbjörn; Leung, Yee Hong
2016-12-01
In recent years, ICA has been one of the more popular methods for extracting event-related potential (ERP) at the single-trial level. It is a blind source separation technique that allows the extraction of an ERP without making strong assumptions on the temporal and spatial characteristics of an ERP. However, the problem with traditional ICA is that the extraction is not direct and is time-consuming due to the need for source selection processing. In this paper, the application of an one-unit ICA-with-Reference (ICA-R), a constrained ICA method, is proposed. In cases where the time-region of the desired ERP is known a priori, this time information is utilized to generate a reference signal, which is then used for guiding the one-unit ICA-R to extract the source signal of the desired ERP directly. Our results showed that, as compared to traditional ICA, ICA-R is a more effective method for analysing ERP because it avoids manual source selection and it requires less computation thus resulting in faster ERP extraction. In addition to that, since the method is automated, it reduces the risks of any subjective bias in the ERP analysis. It is also a potential tool for extracting the ERP in online application.
Single-trial event-related potential extraction through one-unit ICA-with-reference
NASA Astrophysics Data System (ADS)
Lih Lee, Wee; Tan, Tele; Falkmer, Torbjörn; Leung, Yee Hong
2016-12-01
Objective. In recent years, ICA has been one of the more popular methods for extracting event-related potential (ERP) at the single-trial level. It is a blind source separation technique that allows the extraction of an ERP without making strong assumptions on the temporal and spatial characteristics of an ERP. However, the problem with traditional ICA is that the extraction is not direct and is time-consuming due to the need for source selection processing. In this paper, the application of an one-unit ICA-with-Reference (ICA-R), a constrained ICA method, is proposed. Approach. In cases where the time-region of the desired ERP is known a priori, this time information is utilized to generate a reference signal, which is then used for guiding the one-unit ICA-R to extract the source signal of the desired ERP directly. Main results. Our results showed that, as compared to traditional ICA, ICA-R is a more effective method for analysing ERP because it avoids manual source selection and it requires less computation thus resulting in faster ERP extraction. Significance. In addition to that, since the method is automated, it reduces the risks of any subjective bias in the ERP analysis. It is also a potential tool for extracting the ERP in online application.
Ozaki, T; Hata, K; Xie, H; Takahashi, K; Miyazaki, K
2002-12-01
To investigate the relationship between color Doppler indices of dominant follicular blood flow and clinical factors in in vitro fertilization-embryo transfer cycles. This was a prospective study involving 26 patients completing a total of 33 in vitro fertilization cycles. Dominant follicular blood flow indices, peak systolic velocities, the resistance index and the pulsatility index were evaluated using transvaginal color Doppler. The indices were compared to the clinical outcomes of in vitro fertilization-embryo transfer. There was a significant correlation between dominant follicular peak systolic velocities and the number of oocytes retrieved, as well as the number of mature oocytes obtained. There was no significant correlation between dominant follicular resistance index or pulsatility index and the number of follicles > 10 mm in diameter, the number of oocytes retrieved or the number of mature oocytes. There were no significant differences between dominant follicular peak systolic velocities, resistance index or pulsatility index, and fertilization rate or the ratio of good quality embryos. However, significant differences were found between the number of oocytes retrieved, as well as the number of mature oocytes for those patients in which the peak systolic velocity was below 25 cm/s. Doppler assessment of dominant follicle blood flow alone is useful for predicting the number of retrievable oocytes. However, morphological quality of the embryo produced or the pregnancy rate cannot be predicted by this method.
Kıvanç, Sertaç Argun; Kıvanç, Merih; Kılıç, Volkan; Güllülü, Gülay; Özmen, Ahmet Tuncer
2017-01-01
Objectives: To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before. Materials and Methods: Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy. Results: Mean bacterial counts on the IOLs were 7.1±0.4 log10 CFU/mL with the ICA+ isolate, and 6.7±0.8 log10 CFU/mL with the ICA- isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p=0.009 and p=0.013). The highest biofilm production was obtained on IOL C (PMMA) (p<0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p<0.001). Conclusion: Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study. PMID:28405479
Photoacoustic Doppler effect from flowing small light-absorbing particles.
Fang, Hui; Maslov, Konstantin; Wang, Lihong V
2007-11-02
From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.
PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG.
Ball, Kenneth; Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay
2016-01-01
Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals.
PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG
Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay
2016-01-01
Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals. PMID:27340397
Improved FastICA algorithm in fMRI data analysis using the sparsity property of the sources.
Ge, Ruiyang; Wang, Yubao; Zhang, Jipeng; Yao, Li; Zhang, Hang; Long, Zhiying
2016-04-01
As a blind source separation technique, independent component analysis (ICA) has many applications in functional magnetic resonance imaging (fMRI). Although either temporal or spatial prior information has been introduced into the constrained ICA and semi-blind ICA methods to improve the performance of ICA in fMRI data analysis, certain types of additional prior information, such as the sparsity, has seldom been added to the ICA algorithms as constraints. In this study, we proposed a SparseFastICA method by adding the source sparsity as a constraint to the FastICA algorithm to improve the performance of the widely used FastICA. The source sparsity is estimated through a smoothed ℓ0 norm method. We performed experimental tests on both simulated data and real fMRI data to investigate the feasibility and robustness of SparseFastICA and made a performance comparison between SparseFastICA, FastICA and Infomax ICA. Results of the simulated and real fMRI data demonstrated the feasibility and robustness of SparseFastICA for the source separation in fMRI data. Both the simulated and real fMRI experimental results showed that SparseFastICA has better robustness to noise and better spatial detection power than FastICA. Although the spatial detection power of SparseFastICA and Infomax did not show significant difference, SparseFastICA had faster computation speed than Infomax. SparseFastICA was comparable to the Infomax algorithm with a faster computation speed. More importantly, SparseFastICA outperformed FastICA in robustness and spatial detection power and can be used to identify more accurate brain networks than FastICA algorithm. Copyright © 2016 Elsevier B.V. All rights reserved.
Transthoracic Ultrafast Doppler Imaging of Human Left Ventricular Hemodynamic Function
Osmanski, Bruno-Félix; Maresca, David; Messas, Emmanuel; Tanter, Mickael; Pernot, Mathieu
2016-01-01
Heart diseases can affect intraventricular blood flow patterns. Real-time imaging of blood flow patterns is challenging because it requires both a high frame rate and a large field of view. To date, standard Doppler techniques can only perform blood flow estimation with high temporal resolution within small regions of interest. In this work, we used ultrafast imaging to map in 2D human left ventricular blood flow patterns during the whole cardiac cycle. Cylindrical waves were transmitted at 4800 Hz with a transthoracic phased array probe to achieve ultrafast Doppler imaging of the left ventricle. The high spatio-temporal sampling of ultrafast imaging permits to rely on a much more effective wall filtering and to increase sensitivity when mapping blood flow patterns during the pre-ejection, ejection, early diastole, diastasis and late diastole phases of the heart cycle. The superior sensitivity and temporal resolution of ultrafast Doppler imaging makes it a promising tool for the noninvasive study of intraventricular hemodynamic function. PMID:25073134
Bernstein, P S; Minior, V K; Divon, M Y
1997-11-01
The presence of elevated nucleated red blood cell counts in neonatal blood has been associated with fetal hypoxia. We sought to determine whether small-for-gestational-age fetuses with abnormal umbilical artery Doppler velocity waveforms have elevated nucleated red blood cell counts. Hospital charts of neonates with the discharge diagnosis of small for gestational age (birth weight < 10th percentile) who were delivered between October 1988 and June 1995 were reviewed for antepartum testing, delivery conditions, and neonatal outcome. We studied fetuses who had an umbilical artery systolic/diastolic ratio within 3 days of delivery and a complete blood cell count on the first day of life. Multiple gestations, anomalous fetuses, and infants of diabetic mothers were excluded. Statistical analysis included the Student t test, chi 2 analysis, analysis of variance, and simple and stepwise regression. Fifty-two infants met the inclusion criteria. Those with absent or reversed end-diastolic velocity (n = 19) had significantly greater nucleated red blood cell counts than did those with end-diastolic velocity present (n = 33) (nucleated red blood cells/100 nucleated cells +/- SD: 135.5 +/- 138 vs 17.4 +/- 23.7, p < 0.0001). These infants exhibited significantly longer time intervals for clearance of nucleated red blood cells from their circulation (p < 0.0001). They also had lower birth weights (p < 0.05), lower initial platelet count (p = 0.0006), lower arterial cord blood pH (p < 0.05), higher cord blood base deficit (p < 0.05), and an increased likelihood of cesarean section for "fetal distress" (p < 0.05). Multivariate analysis demonstrated that absent or reversed end-diastolic velocity (p < 0.0001) and low birth weight (p < 0.0001) contributed to the elevation of the nucleated red blood cell count, whereas gestational age at delivery was not a significant contributor. We observed significantly greater nucleated red blood cell counts and lower platelet counts in small
NASA Astrophysics Data System (ADS)
Wan, Renzhi; Zu, Yunxiao; Shao, Lin
2018-04-01
The blood echo signal maintained through Medical ultrasound Doppler devices would always include vascular wall pulsation signal .The traditional method to de-noise wall signal is using high-pass filter, which will also remove the lowfrequency part of the blood flow signal. Some scholars put forward a method based on region selective reduction, which at first estimates of the wall pulsation signals and then removes the wall signal from the mixed signal. Apparently, this method uses the correlation between wavelet coefficients to distinguish blood signal from wall signal, but in fact it is a kind of wavelet threshold de-noising method, whose effect is not so much ideal. In order to maintain a better effect, this paper proposes an improved method based on wavelet coefficient correlation to separate blood signal and wall signal, and simulates the algorithm by computer to verify its validity.
Role of diversity in ICA and IVA: theory and applications
NASA Astrophysics Data System (ADS)
Adalı, Tülay
2016-05-01
Independent component analysis (ICA) has been the most popular approach for solving the blind source separation problem. Starting from a simple linear mixing model and the assumption of statistical independence, ICA can recover a set of linearly-mixed sources to within a scaling and permutation ambiguity. It has been successfully applied to numerous data analysis problems in areas as diverse as biomedicine, communications, finance, geo- physics, and remote sensing. ICA can be achieved using different types of diversity—statistical property—and, can be posed to simultaneously account for multiple types of diversity such as higher-order-statistics, sample dependence, non-circularity, and nonstationarity. A recent generalization of ICA, independent vector analysis (IVA), generalizes ICA to multiple data sets and adds the use of one more type of diversity, statistical dependence across the data sets, for jointly achieving independent decomposition of multiple data sets. With the addition of each new diversity type, identification of a broader class of signals become possible, and in the case of IVA, this includes sources that are independent and identically distributed Gaussians. We review the fundamentals and properties of ICA and IVA when multiple types of diversity are taken into account, and then ask the question whether diversity plays an important role in practical applications as well. Examples from various domains are presented to demonstrate that in many scenarios it might be worthwhile to jointly account for multiple statistical properties. This paper is submitted in conjunction with the talk delivered for the "Unsupervised Learning and ICA Pioneer Award" at the 2016 SPIE Conference on Sensing and Analysis Technologies for Biomedical and Cognitive Applications.
Dual antiplatelet therapy in stroke and ICAS: Subgroup analysis of CHANCE.
Liu, Liping; Wong, Ka Sing Lawrence; Leng, Xinyi; Pu, Yuehua; Wang, Yilong; Jing, Jing; Zou, Xinying; Pan, Yuesong; Wang, Anxin; Meng, Xia; Wang, Chunxue; Zhao, Xingquan; Soo, Yannie; Johnston, S Claiborne; Wang, Yongjun
2015-09-29
AB OBJECTIVE: We aimed to investigate whether the efficacy and safety of clopidogrel plus aspirin vs aspirin alone were consistent between patients with and without intracranial arterial stenosis (ICAS), in the Clopidogrel in High-Risk Patients with Acute Non-disabling Cerebrovascular Events (CHANCE) trial. We assessed the interaction of the treatment effects of the 2 antiplatelet therapies among patients with and without ICAS, identified by magnetic resonance angiography (MRA) in CHANCE (ClinicalTrials.gov identifier NCT00979589). Overall, 1,089 patients with MRA images available in CHANCE were included in this subanalysis, 608 patients (55.8%) with ICAS and 481 (44.2%) without. Patients with ICAS had higher rates of recurrent stroke (12.5% vs 5.4%; p<0.0001) at 90 days than those without. But there was no statistically significant treatment by presence of ICAS interaction on either the primary outcome of any stroke (hazard ratio for clopidogrel plus aspirin vs aspirin alone: 0.79 [0.47-1.32] vs 1.12 [0.56-2.25]; interaction p=0.522) or the safety outcome of any bleeding event (interaction p=0.277). The results indicated higher rate of recurrent stroke in minor stroke or high-risk TIA patients with ICAS than in those without. However, there was no significant difference in the response to the 2 antiplatelet therapies between patients with and without ICAS in the CHANCE trial. Classification of evidence: This study provides Class II evidence that for patients with acute minor stroke or TIA with and without ICAS identified by MRA, clopidogrel plus aspirin is not significantly different than aspirin alone in preventing recurrent stroke. © 2015 American Academy of Neurology.
Optimized doppler optical coherence tomography for choroidal capillary vasculature imaging
NASA Astrophysics Data System (ADS)
Liu, Gangjun; Qi, Wenjuan; Yu, Lingfeng; Chen, Zhongping
2011-03-01
In this paper, we analyzed the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images were compared. Blood vessels down to capillary level were able to be obtained with the optimized optical coherence color Doppler and Doppler variance method. For in-vivo imaging of human eyes, bulkmotion induced bulk phase must be identified and removed before using color Doppler method. It was found that the Doppler variance method is not sensitive to bulk motion and the method can be used without removing the bulk phase. A novel, simple and fast segmentation algorithm to indentify retinal pigment epithelium (RPE) was proposed and used to segment the retinal and choroidal layer. The algorithm was based on the detected OCT signal intensity difference between different layers. A spectrometer-based Fourier domain OCT system with a central wavelength of 890 nm and bandwidth of 150nm was used in this study. The 3-dimensional imaging volume contained 120 sequential two dimensional images with 2048 A-lines per image. The total imaging time was 12 seconds and the imaging area was 5x5 mm2.
Limitations and applications of ICA for surface electromyogram.
Djuwari, D; Kumar, D K; Naik, G R; Arjunan, S P; Palaniswami, M
2006-09-01
Surface electromyogram (SEMG) has numerous applications, but the presence of artefacts and noise, especially at low level of muscle activity make the recordings unreliable. Spectral and temporal overlap can make the removal of artefacts and noise, or separation of relevant signals from other bioelectric signals extremely difficult. Individual muscles may be considered as independent at the local level and this makes an argument for separating the signals using independent component analysis (ICA). In the recent past, due to the easy availability of ICA tools, numbers of researchers have attempted to use ICA for this application. This paper reports research conducted to evaluate the use of ICA for the separation of muscle activity and removal of the artefacts from SEMG. It discusses some of the conditions that could affect the reliability of the separation and evaluates issues related to the properties of the signals and number of sources. The paper also identifies the lack of suitable measure of quality of separation for bioelectric signals and it recommends and tests a more robust measure of separation. The paper also reports tests using Zibulevsky's technique of temporal plotting to identify number of independent sources in SEMG recordings. The theoretical analysis and experimental results demonstrate that ICA is suitable for SEMG signals. The results identify the unsuitability of ICA when the number of sources is greater than the number of recording channels. The results also demonstrate the limitations of such applications due to the inability of the system to identify the correct order and magnitude of the signals. The paper determines the suitability of the use of error measure using simulated mixing matrix and the estimated unmixing matrix as a means identifying the quality of separation of the output. The work demonstrates that even at extremely low level of muscle contraction, and with filtering using wavelets and band pass filters, it is not possible to
Variability of ICA decomposition may impact EEG signals when used to remove eyeblink artifacts
PONTIFEX, MATTHEW B.; GWIZDALA, KATHRYN L.; PARKS, ANDREW C.; BILLINGER, MARTIN; BRUNNER, CLEMENS
2017-01-01
Despite the growing use of independent component analysis (ICA) algorithms for isolating and removing eyeblink-related activity from EEG data, we have limited understanding of how variability associated with ICA uncertainty may be influencing the reconstructed EEG signal after removing the eyeblink artifact components. To characterize the magnitude of this ICA uncertainty and to understand the extent to which it may influence findings within ERP and EEG investigations, ICA decompositions of EEG data from 32 college-aged young adults were repeated 30 times for three popular ICA algorithms. Following each decomposition, eyeblink components were identified and removed. The remaining components were back-projected, and the resulting clean EEG data were further used to analyze ERPs. Findings revealed that ICA uncertainty results in variation in P3 amplitude as well as variation across all EEG sampling points, but differs across ICA algorithms as a function of the spatial location of the EEG channel. This investigation highlights the potential of ICA uncertainty to introduce additional sources of variance when the data are back-projected without artifact components. Careful selection of ICA algorithms and parameters can reduce the extent to which ICA uncertainty may introduce an additional source of variance within ERP/EEG studies. PMID:28026876
Chen, Zikuan; Calhoun, Vince D
2016-03-01
Conventionally, independent component analysis (ICA) is performed on an fMRI magnitude dataset to analyze brain functional mapping (AICA). By solving the inverse problem of fMRI, we can reconstruct the brain magnetic susceptibility (χ) functional states. Upon the reconstructed χ dataspace, we propose an ICA-based brain functional χ mapping method (χICA) to extract task-evoked brain functional map. A complex division algorithm is applied to a timeseries of fMRI phase images to extract temporal phase changes (relative to an OFF-state snapshot). A computed inverse MRI (CIMRI) model is used to reconstruct a 4D brain χ response dataset. χICA is implemented by applying a spatial InfoMax ICA algorithm to the reconstructed 4D χ dataspace. With finger-tapping experiments on a 7T system, the χICA-extracted χ-depicted functional map is similar to the SPM-inferred functional χ map by a spatial correlation of 0.67 ± 0.05. In comparison, the AICA-extracted magnitude-depicted map is correlated with the SPM magnitude map by 0.81 ± 0.05. The understanding of the inferiority of χICA to AICA for task-evoked functional map is an ongoing research topic. For task-evoked brain functional mapping, we compare the data-driven ICA method with the task-correlated SPM method. In particular, we compare χICA with AICA for extracting task-correlated timecourses and functional maps. χICA can extract a χ-depicted task-evoked brain functional map from a reconstructed χ dataspace without the knowledge about brain hemodynamic responses. The χICA-extracted brain functional χ map reveals a bidirectional BOLD response pattern that is unavailable (or different) from AICA. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparison of multi-subject ICA methods for analysis of fMRI data
Erhardt, Erik Barry; Rachakonda, Srinivas; Bedrick, Edward; Allen, Elena; Adali, Tülay; Calhoun, Vince D.
2010-01-01
Spatial independent component analysis (ICA) applied to functional magnetic resonance imaging (fMRI) data identifies functionally connected networks by estimating spatially independent patterns from their linearly mixed fMRI signals. Several multi-subject ICA approaches estimating subject-specific time courses (TCs) and spatial maps (SMs) have been developed, however there has not yet been a full comparison of the implications of their use. Here, we provide extensive comparisons of four multi-subject ICA approaches in combination with data reduction methods for simulated and fMRI task data. For multi-subject ICA, the data first undergo reduction at the subject and group levels using principal component analysis (PCA). Comparisons of subject-specific, spatial concatenation, and group data mean subject-level reduction strategies using PCA and probabilistic PCA (PPCA) show that computationally intensive PPCA is equivalent to PCA, and that subject-specific and group data mean subject-level PCA are preferred because of well-estimated TCs and SMs. Second, aggregate independent components are estimated using either noise free ICA or probabilistic ICA (PICA). Third, subject-specific SMs and TCs are estimated using back-reconstruction. We compare several direct group ICA (GICA) back-reconstruction approaches (GICA1-GICA3) and an indirect back-reconstruction approach, spatio-temporal regression (STR, or dual regression). Results show the earlier group ICA (GICA1) approximates STR, however STR has contradictory assumptions and may show mixed-component artifacts in estimated SMs. Our evidence-based recommendation is to use GICA3, introduced here, with subject-specific PCA and noise-free ICA, providing the most robust and accurate estimated SMs and TCs in addition to offering an intuitive interpretation. PMID:21162045
Doppler and speckle methods for diagnostics in dentistry
NASA Astrophysics Data System (ADS)
Ulyanov, Sergey S.; Lepilin, Alexander V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Kharish, Natalia A.; Osipova, Yulia; Karpovich, Alexander
2002-02-01
The results of statistical analysis of Doppler spectra of scattered intensity, obtained from tissues of oral cavity membrane of healthy volunteers, are presented. The dependence of the spectral moments of Doppler signal on cutoff frequency is investigated. Some results of statistical analysis of Doppler spectra, obtained from tooth pulp of patients, are presented. New approach for monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of measuring system on formation of speckle-interferometric signal is studied.
Performance of Blind Source Separation Algorithms for FMRI Analysis using a Group ICA Method
Correa, Nicolle; Adali, Tülay; Calhoun, Vince D.
2007-01-01
Independent component analysis (ICA) is a popular blind source separation (BSS) technique that has proven to be promising for the analysis of functional magnetic resonance imaging (fMRI) data. A number of ICA approaches have been used for fMRI data analysis, and even more ICA algorithms exist, however the impact of using different algorithms on the results is largely unexplored. In this paper, we study the performance of four major classes of algorithms for spatial ICA, namely information maximization, maximization of non-gaussianity, joint diagonalization of cross-cumulant matrices, and second-order correlation based methods when they are applied to fMRI data from subjects performing a visuo-motor task. We use a group ICA method to study the variability among different ICA algorithms and propose several analysis techniques to evaluate their performance. We compare how different ICA algorithms estimate activations in expected neuronal areas. The results demonstrate that the ICA algorithms using higher-order statistical information prove to be quite consistent for fMRI data analysis. Infomax, FastICA, and JADE all yield reliable results; each having their strengths in specific areas. EVD, an algorithm using second-order statistics, does not perform reliably for fMRI data. Additionally, for the iterative ICA algorithms, it is important to investigate the variability of the estimates from different runs. We test the consistency of the iterative algorithms, Infomax and FastICA, by running the algorithm a number of times with different initializations and note that they yield consistent results over these multiple runs. Our results greatly improve our confidence in the consistency of ICA for fMRI data analysis. PMID:17540281
Regulation of neuromuscular junction organization by Rab2 and its effector ICA69 in Drosophila.
Mallik, Bhagaban; Dwivedi, Manish Kumar; Mushtaq, Zeeshan; Kumari, Manisha; Verma, Praveen Kumar; Kumar, Vimlesh
2017-06-01
The mechanisms underlying synaptic differentiation, which involves neuronal membrane and cytoskeletal remodeling, are not completely understood. We performed a targeted RNAi-mediated screen of Drosophila BAR-domain proteins and identified islet cell autoantigen 69 kDa (ICA69) as one of the key regulators of morphological differentiation of the larval neuromuscular junction (NMJ). We show that Drosophila ICA69 colocalizes with α-Spectrin at the NMJ. The conserved N-BAR domain of ICA69 deforms liposomes in vitro Full-length ICA69 and the ICAC but not the N-BAR domain of ICA69 induce filopodia in cultured cells. Consistent with its cytoskeleton regulatory role, ICA69 mutants show reduced α-Spectrin immunoreactivity at the larval NMJ. Manipulating levels of ICA69 or its interactor PICK1 alters the synaptic level of ionotropic glutamate receptors (iGluRs). Moreover, reducing PICK1 or Rab2 levels phenocopies ICA69 mutation. Interestingly, Rab2 regulates not only synaptic iGluR but also ICA69 levels. Thus, our data suggest that: (1) ICA69 regulates NMJ organization through a pathway that involves PICK1 and Rab2, and (2) Rab2 functions genetically upstream of ICA69 and regulates NMJ organization and targeting/retention of iGluRs by regulating ICA69 levels. © 2017. Published by The Company of Biologists Ltd.
Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen
2017-01-01
To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P < 0.05). The mean VRRs of all BTNs were 23.4%, 54.4% and 81.9% at the 1-, 3- and 6-month follow-up, respectively. All BTNs achieved therapeutic success in this series in that all had VRRs of >50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P < 0
Dynamic spatio-temporal imaging of early reflow in a neonatal rat stroke model.
Leger, Pierre-Louis; Bonnin, Philippe; Lacombe, Pierre; Couture-Lepetit, Elisabeth; Fau, Sebastien; Renolleau, Sylvain; Gharib, Abdallah; Baud, Olivier; Charriaut-Marlangue, Christiane
2013-01-01
The aim of the study was to better understand blood-flow changes in large arteries and microvessels during the first 15 minutes of reflow in a P7 rat model of arterial occlusion. Blood-flow changes were monitored by using ultrasound imaging with sequential Doppler recordings in internal carotid arteries (ICAs) and basilar trunk. Relative cerebral blood flow (rCBF) changes were obtained by using laser speckle Doppler monitoring. Tissue perfusion was measured with [(14)C]-iodoantipyrine autoradiography. Cerebral energy metabolism was evaluated by mitochondrial oxygen consumption. Gradual increase in mean blood-flow velocities illustrated a gradual perfusion during early reflow in both ICAs. On ischemia, the middle cerebral artery (MCA) territory presented a residual perfusion, whereas the caudal territory remained normally perfused. On reflow, speckle images showed a caudorostral propagation of reperfusion through anastomotic connections, and a reduced perfusion in the MCA territory. Autoradiography highlighted the caudorostral gradient, and persistent perfusion in ventral and medial regions. These blood-flow changes were accompanied by mitochondrial respiration impairment in the ipsilateral cortex. Collectively, these data indicate the presence of a primary collateral pathway through the circle of Willis, providing an immediate diversion of blood flow toward ischemic regions, and secondary efficient cortical anastomoses in the immature rat brain.
Blood flow velocity in monocular retinoblastoma assessed by color doppler
Bonanomi, Maria Teresa B C; Saito, Osmar C; de Lima, Patricia Picciarelli; Bonanomi, Roberta Chizzotti; Chammas, Maria Cristina
2015-01-01
OBJECTIVE: To analyze the flow of retrobulbar vessels in retinoblastoma by color Doppler imaging. METHODS: A prospective study of monocular retinoblastoma treated by enucleation between 2010 and 2014. The examination comprised fundoscopy, magnetic resonance imaging, ultrasonography and color Doppler imaging. The peak blood velocities in the central retinal artery and central retinal vein of tumor-containing eyes (tuCRAv and tuCRVv, respectively) were assessed. The velocities were compared with those for normal eyes (nlCRAv and nlCRVv) and correlated with clinical and pathological findings. Tumor dimensions in the pathological sections were compared with those in magnetic resonance imaging and ultrasonography and were correlated with tuCRAv and tuCRVv. In tumor-containing eyes, the resistivity index in the central retinal artery and the pulse index in the central retinal vein were studied in relation to all variables. RESULTS: Eighteen patients were included. Comparisons between tuCRAv and nlCRAv and between tuCRVv and nlCRVv revealed higher velocities in tumor-containing eyes (p<0.001 for both), with a greater effect in the central retinal artery than in the central retinal vein (p=0.024). Magnetic resonance imaging and ultrasonography measurements were as reliable as pathology assessments (p=0.675 and p=0.375, respectively). A positive relationship was found between tuCRAv and the tumor volume (p=0.027). The pulse index in the central retinal vein was lower in male patients (p=0.017) and in eyes with optic nerve invasion (p=0.0088). CONCLUSIONS: TuCRAv and tuCRVv are higher in tumor-containing eyes than in normal eyes. Magnetic resonance imaging and ultrasonography measurements are reliable. The tumor volume is correlated with a higher tuCRAv and a reduced pulse in the central retinal vein is correlated with male sex and optic nerve invasion. PMID:26735219
Grouping individual independent BOLD effects: a new way to ICA group analysis
NASA Astrophysics Data System (ADS)
Duann, Jeng-Ren; Jung, Tzyy-Ping; Sejnowski, Terrence J.; Makeig, Scott
2009-04-01
A new group analysis method to summarize the task-related BOLD responses based on independent component analysis (ICA) was presented. As opposite to the previously proposed group ICA (gICA) method, which first combined multi-subject fMRI data in either temporal or spatial domain and applied ICA decomposition only once to the combined fMRI data to extract the task-related BOLD effects, the method presented here applied ICA decomposition to the individual subjects' fMRI data to first find the independent BOLD effects specifically for each individual subject. Then, the task-related independent BOLD component was selected among the resulting independent components from the single-subject ICA decomposition and hence grouped across subjects to derive the group inference. In this new ICA group analysis (ICAga) method, one does not need to assume that the task-related BOLD time courses are identical across brain areas and subjects as used in the grand ICA decomposition on the spatially concatenated fMRI data. Neither does one need to assume that after spatial normalization, the voxels at the same coordinates represent exactly the same functional or structural brain anatomies across different subjects. These two assumptions have been problematic given the recent BOLD activation evidences. Further, since the independent BOLD effects were obtained from each individual subject, the ICAga method can better account for the individual differences in the task-related BOLD effects. Unlike the gICA approach whereby the task-related BOLD effects could only be accounted for by a single unified BOLD model across multiple subjects. As a result, the newly proposed method, ICAga, was able to better fit the task-related BOLD effects at individual level and thus allow grouping more appropriate multisubject BOLD effects in the group analysis.
Takayama, Shin; Watanabe, Masashi; Kusuyama, Hiroko; Nagase, Satoru; Seki, Takashi; Nakazawa, Toru; Yaegashi, Nobuo
2012-01-01
Color Doppler imaging (CDI) can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA) during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture. PMID:22778772
NASA Astrophysics Data System (ADS)
Elahi, Sahar; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.
2017-02-01
Altered hemodynamics in developing embryonic hearts lead to congenital heart diseases, motivating close monitoring of blood flow over several stages of development. Doppler OCT can assess blood flow in tubular hearts, but the maximum velocity increases drastically during the period of cardiac cushion (valve precursors) formation. Therefore, the limited dynamic range of Doppler OCT velocity measurement makes it difficult to conduct longitudinal studies without phase wrapping at high velocities or loss of sensitivity to slow velocities. We have built a high-speed OCT system using an FDML laser (Optores GmbH, Germany) at a sweep rate of 1.68 MHz (axial resolution - 12 μm, sensitivity - 105 dB, phase stability - 17 mrad). The speed of this OCT system allows us to acquire high-density B-scans to obtain an extended velocity dynamic range without sacrificing the frame rate. The extended dynamic range within a frame is achieved by varying the A-scan interval at which the phase difference is found, enabling detection of velocities ranging from tens of microns per second to hundreds of mm per second. The extra lines in a frame can also be utilized to improve the structural and Doppler images via complex averaging. In structural images where presence of blood causes additional scattering, complex averaging helps retrieve features located deeper in the tissue. Moreover, high-density frames can be registered to 4D volumes to determine the orthogonal direction of flow and calculate shear stress. In conclusion, our high-speed OCT system will enable automated Doppler imaging of embryonic hearts in cohort studies.
[Per partum acidosis: Interest and feasibility of cerebral Doppler during labor].
Barrois, M; Chartier, M; Lecarpentier, E; Goffinet, F; Tsatsaris, V
2016-09-01
To evaluate feasibility and interest of fetal cerebral Doppler during labor and the link with fetal pH to predict perinatal fetal asphyxia. Our prospective study in a university perinatal center, included patients during labor. There were no risk factors during pregnancy and patients were included after 37 weeks of pregnancy. For each patient an ultrasound with cerebral Doppler was done concomitant to a fetal scalp blood sample. We collected maternal and fetal characteristics as well as cervix dilatation, fetal heart rate analysis and fetal presentation. Among 49 patients included over a period of 4 months, cerebral Doppler failed in 7 cases (11%). Majority of failure occurred at 10cm of dilatation (P=0.007, OR=14.1 [1.483; 709.1275]). Others factors like: maternal age, body mass index, parity, history of C-Section were not associated with higher rate of failure. We did not found either significant correlation between cerebral fetal Doppler and pH on fetal scalp blood sample (r=0.15) nor pH at cord blood sample (r=0.13). No threshold of cerebral Doppler is significant for fetal asphyxia prediction. Fetal cerebral Doppler is feasible during labor with a low rate of failure but not a good exam to predict fetal acidosis and asphyxia. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Kijsamanmith, Kanittha; Timpawat, Siriporn; Vongsavan, Noppakun; Matthews, Bruce
2011-07-01
To compare red (635 nm) and infrared (780 nm) light for recording pulpal blood flow from human premolar teeth. Recordings were made from 11 healthy teeth in 9 subjects (aged 16-30 years) using a laser Doppler flow meter (Periflux 4001) equipped with both red and infrared lasers. Average blood flow signals were obtained with both light sources alternately from each tooth under five conditions: intact tooth without opaque rubber dam, intact tooth with dam, after injecting local anaesthetic (3% Mepivacaine) (LA) over the apex of the tooth and cavity preparation to almost expose the pulp, after removal and replacement of the pulp, and with the root canal empty. With infrared light, the dam significantly decreased the mean blood flow by 80%. Injecting LA and cavity preparation had no significant effect. Removal and replacement of the pulp reduced the mean blood flow by 58%. There was no further change when the pulp was removed. With red light, the dam reduced the signal from intact teeth by 60%. Injecting LA and cavity preparation had no significant effect. The signal fell by 67% after pulp removal and replacement and did not change significantly when the pulp was removed. Opaque rubber dam minimises the contribution of non-pulpal tissues to the laser Doppler signal recorded from premolars. Using dam, the pulp contributed about 60% to the blood flow signal with both red and infrared light. The difference between them in this respect was not significant. Copyright © 2010 Elsevier Ltd. All rights reserved.
Spectroscopic Doppler analysis for visible-light optical coherence tomography
NASA Astrophysics Data System (ADS)
Shu, Xiao; Liu, Wenzhong; Duan, Lian; Zhang, Hao F.
2017-12-01
Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.
Performance of blind source separation algorithms for fMRI analysis using a group ICA method.
Correa, Nicolle; Adali, Tülay; Calhoun, Vince D
2007-06-01
Independent component analysis (ICA) is a popular blind source separation technique that has proven to be promising for the analysis of functional magnetic resonance imaging (fMRI) data. A number of ICA approaches have been used for fMRI data analysis, and even more ICA algorithms exist; however, the impact of using different algorithms on the results is largely unexplored. In this paper, we study the performance of four major classes of algorithms for spatial ICA, namely, information maximization, maximization of non-Gaussianity, joint diagonalization of cross-cumulant matrices and second-order correlation-based methods, when they are applied to fMRI data from subjects performing a visuo-motor task. We use a group ICA method to study variability among different ICA algorithms, and we propose several analysis techniques to evaluate their performance. We compare how different ICA algorithms estimate activations in expected neuronal areas. The results demonstrate that the ICA algorithms using higher-order statistical information prove to be quite consistent for fMRI data analysis. Infomax, FastICA and joint approximate diagonalization of eigenmatrices (JADE) all yield reliable results, with each having its strengths in specific areas. Eigenvalue decomposition (EVD), an algorithm using second-order statistics, does not perform reliably for fMRI data. Additionally, for iterative ICA algorithms, it is important to investigate the variability of estimates from different runs. We test the consistency of the iterative algorithms Infomax and FastICA by running the algorithm a number of times with different initializations, and we note that they yield consistent results over these multiple runs. Our results greatly improve our confidence in the consistency of ICA for fMRI data analysis.
Developmental changes in cerebral and visceral blood flow velocity in healthy neonates and infants.
Ilves, Pilvi; Lintrop, Mare; Talvik, Inga; Muug, Külli; Asser, Karin; Veinla, Maie
2008-02-01
The purpose of this study was to evaluate the changes in Doppler blood flow velocity (BFV) in cerebral and visceral arteries during infancy. The BFV was measured in 37 healthy term neonates in the anterior cerebral artery (ACA), middle cerebral artery (MCA), basilar artery, internal carotid artery (ICA), celiac artery (CA), superior mesenteric artery (SMA), and renal artery (RA). The mean BFV increased and the resistive index decreased (P < .05) in all cerebral arteries, SMA, and CA by the age of 12 to 23.9 hours and in the RA by the age of 24 to 35.9 hours compared with 2 to 11.9 hours. A further significant increase (P < .05) of the mean BFV occurred in all arteries except the ICA and CA by the age of 72 to 120 hours compared with 12 to 23.9 hours. By the age of 21 to 59 days, the mean BVF doubled in all investigated arteries compared with 2 to 11.9 hours, with a further significant increase (P < .05) by the age of 150 to 240 days in cerebral and renal arteries. There was no correlation between the mean blood pressure (BP) and mean BFV in the ACA and MCA. However, there was a positive correlation (r > or = 0.5; P < .05) between the BP and BFV in the RA and SMA at the age of 12 to 23.9 hours. A significant increase in the cerebral and visceral BFV occurs normally throughout infancy, with the visceral BFV affected by BP changes during the first day of life.
Artifact removal in the context of group ICA: a comparison of single-subject and group approaches
Du, Yuhui; Allen, Elena A.; He, Hao; Sui, Jing; Wu, Lei; Calhoun, Vince D.
2018-01-01
Independent component analysis (ICA) has been widely applied to identify intrinsic brain networks from fMRI data. Group ICA computes group-level components from all data and subsequently estimates individual-level components to recapture inter-subject variability. However, the best approach to handle artifacts, which may vary widely among subjects, is not yet clear. In this work, we study and compare two ICA approaches for artifacts removal. One approach, recommended in recent work by the Human Connectome Project, first performs ICA on individual subject data to remove artifacts, and then applies a group ICA on the cleaned data from all subjects. We refer to this approach as Individual ICA based artifacts Removal Plus Group ICA (IRPG). A second proposed approach, called Group Information Guided ICA (GIG-ICA), performs ICA on group data, then removes the group-level artifact components, and finally performs subject-specific ICAs using the group-level non-artifact components as spatial references. We used simulations to evaluate the two approaches with respect to the effects of data quality, data quantity, variable number of sources among subjects, and spatially unique artifacts. Resting-state test-retest datasets were also employed to investigate the reliability of functional networks. Results from simulations demonstrate GIG-ICA has greater performance compared to IRPG, even in the case when single-subject artifacts removal is perfect and when individual subjects have spatially unique artifacts. Experiments using test-retest data suggest that GIG-ICA provides more reliable functional networks. Based on high estimation accuracy, ease of implementation, and high reliability of functional networks, we find GIG-ICA to be a promising approach. PMID:26859308
Schneiders, J J; Ferns, S P; van Ooij, P; Siebes, M; Nederveen, A J; van den Berg, R; van Lieshout, J; Jansen, G; vanBavel, E; Majoie, C B
2012-10-01
Local hemodynamic information may help to stratify rupture risk of cerebral aneurysms. Patient-specific modeling of cerebral hemodynamics requires accurate data on BFV in perianeurysmal arteries as boundary conditions for CFD. The aim was to compare the BFV measured with PC-MR imaging with that obtained by using intra-arterial Doppler sonography and to determine interpatient variation in intracranial BFV. In 10 patients with unruptured intracranial aneurysms, BFV was measured in the cavernous ICA with PC-MR imaging in conscious patients before treatment, and measured by using an intra-arterial Doppler sonography wire when the patient was anesthetized with either propofol (6 patients) or sevoflurane (4 patients). Both techniques identified a pulsatile blood flow pattern in cerebral arteries. PSV differed >50 cm/s between patients. A mean velocity of 41.3 cm/s (95% CI, 39.3-43.3) was measured with PC-MR imaging. With intra-arterial Doppler sonography, a mean velocity of 29.3 cm/s (95% CI, 25.8-32.8) was measured with the patient under propofol-based intravenous anesthesia. In patients under sevoflurane-based inhaled anesthesia, a mean velocity of 44.9 cm/s (95% CI, 40.6-49.3) was measured. We showed large differences in BFV between patients, emphasizing the importance of using patient-specific hemodynamic boundary conditions in CFD. PC-MR imaging measurements of BFV in conscious patients were comparable with those obtained with the intra-arterial Doppler sonography when the patient was anesthetized with a sevoflurane-based inhaled anesthetic.
Tan, Ou; Liu, Gangjun; Liang, Liu; Gao, Simon S.; Pechauer, Alex D.; Jia, Yali; Huang, David
2015-01-01
Abstract. An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans (2×2 mm) obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was 45.4±6.7 μl/min for healthy control and 34.7±7.6 μl/min for glaucomatous participants (p-value=0.01). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement. PMID:26062663
Doppler velocity measurements from large and small arteries of mice
Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.
2011-01-01
With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013
NASA Astrophysics Data System (ADS)
Davis, Anjul M.; Rothenberg, Florence G.; Law, Tzuo H.; Taber, Larry A.; Izatt, Joseph A.
2007-02-01
The onset of congenital heart disease (CHD) is believed to occur at very early stages of development. Investigations in the initiation and development of CHD has been hampered by the inability to image early stage heart structure and function, in vivo. Imaging small animals using optical coherence tomography (OCT) has filled a niche between the limited penetration depth of confocal microscopy and insufficient resolution from ultrasound. Previous demonstrations of chick heart imaging using OCT have entailed excision of, or arresting the heart to prevent motion artifacts. In this summary, we introduce SDOCT Doppler velocimetry as an enhancement of Doppler OCT for in vivo measurement of localized temporal blood flow dynamics. With this technique, dynamic velocity waveforms were measured in the outflow tract of the heart tube. These flow dynamics correlate to a finite element model of pulsatile flow and may lead to a further understanding of morphological influences on early heart development.
A new statistical PCA-ICA algorithm for location of R-peaks in ECG.
Chawla, M P S; Verma, H K; Kumar, Vinod
2008-09-16
The success of ICA to separate the independent components from the mixture depends on the properties of the electrocardiogram (ECG) recordings. This paper discusses some of the conditions of independent component analysis (ICA) that could affect the reliability of the separation and evaluation of issues related to the properties of the signals and number of sources. Principal component analysis (PCA) scatter plots are plotted to indicate the diagnostic features in the presence and absence of base-line wander in interpreting the ECG signals. In this analysis, a newly developed statistical algorithm by authors, based on the use of combined PCA-ICA for two correlated channels of 12-channel ECG data is proposed. ICA technique has been successfully implemented in identifying and removal of noise and artifacts from ECG signals. Cleaned ECG signals are obtained using statistical measures like kurtosis and variance of variance after ICA processing. This analysis also paper deals with the detection of QRS complexes in electrocardiograms using combined PCA-ICA algorithm. The efficacy of the combined PCA-ICA algorithm lies in the fact that the location of the R-peaks is bounded from above and below by the location of the cross-over points, hence none of the peaks are ignored or missed.
Computational modeling of HHH therapy and impact of blood pressure and hematocrit.
Robinson, Joe Sam; Walid, M Sami; Hyun, Sinjae; O'Connell, Robert; Menard, Chris; Bohleber, Brandi
2010-01-01
After an aneurysmal subarachnoid hemorrhage, cerebral microcirculatory changes occur as a result cerebral vasospasm. The objective of this study is to investigate, with a computational model, how various degrees of vasospasm are influenced by increasing the mean blood pressure and decreasing the blood viscosity. Using ANSYS CFX software, a computational model was constructed to simulate steady-state fully developed laminar blood flow through a rigid wall system consisting of the internal carotid artery (ICA), anterior cerebral artery, posterior cerebral artery, and middle cerebral artery (MCA). The MCA was selected for the site of a single acute vasospasm. Five severities of vasospasm were studied: 3 mm (normal), 2.5, 2, 1.5, and 1 mm. The ICA was assumed to have a constant inlet flow rate of 315 mL/min. The anterior cerebral artery and posterior cerebral artery were assumed to have constant outlet flow rates of 105 mL/min and 30 mL/min, respectively. The MCA was assumed to have a constant outlet pressure of 92 mL/min. Two different hematocrits, 45% and 32%, were simulated using the models. For a hematocrit of 45, the mean ICA inlet pressure required to pump blood through the system was 104 mm Hg for the 3-mm diameter MCA and 105, 108, 116, and 158 mm Hg for vasospasm diameters of 2.5, 2, 1.5, and 1 mm, respectively. For a hematocrit of 32, the mean ICA inlet pressure required was 102, 103, 105, 113, and 152 mm Hg, respectively. The MCA required a large increase in mean ICA inlet pressure for vasospasm diameters less than 1.5 mm, which suggests that for vasospasms more than 50% diameter reduction, the blood pressure must be increased dramatically. Decreasing the hematocrit had minimal impact on blood flow in a constricted vessel. Copyright © 2010 Elsevier Inc. All rights reserved.
Insoo Kim; Bhagat, Yusuf A
2016-08-01
The standard in noninvasive blood pressure (BP) measurement is an inflatable cuff device based on the oscillometric method, which poses several practical challenges for continuous BP monitoring. Here, we present a novel ultra-wide band RF Doppler radar sensor for next-generation mobile interface for the purpose of characterizing fluid flow speeds, and for ultimately measuring cuffless blood flow in the human wrist. The system takes advantage of the 7.1~10.5 GHz ultra-wide band signals which can reduce transceiver complexity and power consumption overhead. Moreover, results obtained from hardware development, antenna design and human wrist modeling, and subsequent phantom development are reported. Our comprehensive lab bench system setup with a peristaltic pump was capable of characterizing various speed flow components during a linear velocity sweep of 5~62 cm/s. The sensor holds potential for providing estimates of heart rate and blood pressure.
Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H
2006-01-01
Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Subject order-independent group ICA (SOI-GICA) for functional MRI data analysis.
Zhang, Han; Zuo, Xi-Nian; Ma, Shuang-Ye; Zang, Yu-Feng; Milham, Michael P; Zhu, Chao-Zhe
2010-07-15
Independent component analysis (ICA) is a data-driven approach to study functional magnetic resonance imaging (fMRI) data. Particularly, for group analysis on multiple subjects, temporally concatenation group ICA (TC-GICA) is intensively used. However, due to the usually limited computational capability, data reduction with principal component analysis (PCA: a standard preprocessing step of ICA decomposition) is difficult to achieve for a large dataset. To overcome this, TC-GICA employs multiple-stage PCA data reduction. Such multiple-stage PCA data reduction, however, leads to variable outputs due to different subject concatenation orders. Consequently, the ICA algorithm uses the variable multiple-stage PCA outputs and generates variable decompositions. In this study, a rigorous theoretical analysis was conducted to prove the existence of such variability. Simulated and real fMRI experiments were used to demonstrate the subject-order-induced variability of TC-GICA results using multiple PCA data reductions. To solve this problem, we propose a new subject order-independent group ICA (SOI-GICA). Both simulated and real fMRI data experiments demonstrated the high robustness and accuracy of the SOI-GICA results compared to those of traditional TC-GICA. Accordingly, we recommend SOI-GICA for group ICA-based fMRI studies, especially those with large data sets. Copyright 2010 Elsevier Inc. All rights reserved.
Murray, A K; Moore, T L; Griffiths, C E M; Herrick, A L
2009-07-01
Superficial telangiectases associated with systemic sclerosis may be more responsive to treatment than those deeper in the dermis. We investigated whether dual-wavelength laser Doppler imaging (LDI) is sufficiently sensitive to ascertain the distribution of blood flow within telangiectases and whether blood flow relates to telangiectatic diameter. The perfusion and diameter of 20 telangiectases were measured in superficial and deeper layers of the skin using dual-wavelength LDI. Of 20 telangiectases, 18 had higher blood flow in the red (representing deeper blood flow), rather than the green (representing superficial blood flow) wavelength images. Clinically apparent diameters correlated with those of the superficial (r = 0.61, P = 0.01), but not with the deeper blood flow images. Hence, the apparent size of telangiectases at the skin surface does not predict blood flow through the microvessel(s) at deeper levels, and thus clinically apparent size is unlikely to predict treatment response. Dual-wavelength LDI may help predict treatment response.
A low cost Doppler system for vascular dialysis access surveillance.
Molina, P S C; Moraes, R; Baggio, J F R; Tognon, E A
2004-01-01
The National Kidney Foundation guidelines for vascular access recommend access surveillance to avoid morbidity among patients undergoing hemodialysis. Methods to detect access failure based on CW Doppler system are being proposed to implement surveillance programs at lower cost. This work describes a low cost Doppler system implemented in a PC notebook designed to carry out this task. A Doppler board samples the blood flow velocity and delivers demodulated quadrature Doppler signals. These signals are sampled by a notebook sound card. Software for Windows OS (running at the notebook) applies CFFT to consecutive 11.6 ms intervals of Doppler signals. The sonogram is presented on the screen in real time. The software also calculates the maximum and the intensity weighted mean frequency envelopes. Since similar systems employ DSP boards to process the Doppler signals, cost reduction was achieved. The Doppler board electronic circuits and routines to process the Doppler signals are presented.
Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.
He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P
2013-09-18
The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.
Agarwal, Astha; Jain, Amita
2013-01-01
All colonizing and invasive staphylococcal isolates may not produce biofilm but may turn biofilm producers in certain situations due to change in environmental factors. This study was done to test the hypothesis that non biofilm producing clinical staphylococci isolates turn biofilm producers in presence of sodium chloride (isotonic) and high concentration of glucose, irrespective of presence or absence of ica operon. Clinical isolates of 100 invasive, 50 colonizing and 50 commensal staphylococci were tested for biofilm production by microtiter plate method in different culture media (trypticase soy broth alone or supplemented with 0.9% NaCl/ 5 or 10% glucose). All isolates were tested for the presence of ica ADBC genes by PCR. Biofilm production significantly increased in the presence of glucose and saline, most, when both glucose and saline were used together. All the ica positive staphylococcal isolates and some ica negative isolates turned biofilm producer in at least one of the tested culture conditions. Those remained biofilm negative in different culture conditions were all ica negative. The present results showed that the use of glucose or NaCl or combination of both enhanced biofilm producing capacity of staphylococcal isolates irrespective of presence or absence of ica operon.
Doppler imaging using spectrally-encoded endoscopy
Yelin, Dvir; Bouma, B. E.; Rosowsky, J. J.; Tearney, G. J.
2009-01-01
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique that utilizes a single optical fiber and miniature diffractive optics to obtain endoscopic images through small diameter probes. Using spectral-domain interferometry, SEE is furthermore capable of three-dimensional volume imaging at video rates. Here we show that by measuring relative spectral phases, this technology can additionally measure Doppler shifts. Doppler SEE is demonstrated in flowing Intralipid phantoms and vibrating middle ear ossicles. PMID:18795020
Investigation of laser Doppler techniques using the Monte Carlo method
NASA Astrophysics Data System (ADS)
Ruetten, Walter; Gellekum, Thomas; Jessen, Katrin
1995-01-01
Laser Doppler techniques are increasingly used in research and clinical applications to study perfusion phenomena in the skin, yet the influences of changing scattering parameters and geometry on the measure of perfusion are not well explored. To investigate these influences, a simulation program based on the Monte Carlo method was developed, which is capable of determining the Doppler spectra caused by moving red blood cells. The simulation model allows for the definition of arbitrary networks of blood vessels with individual velocities. The volume is represented by a voxel tree with adaptive spatial resolution which contains references to the optical properties and is used to store the location dependent photon fluence determined during the simulation. Two evaluation methods for Doppler spectra from biological tissue described in the literate were investigated with the simulation program. The results obtained suggest that both methods give a measure of perfusion nearly proportional to the velocity of the red blood cells. However, simulations done with different geometries of the blood vessels seem to indicate a nonlinear behavior concerning the concentration of red blood cells in the measurement volume. Nevertheless these simulation results may help in the interpretation of measurements obtained from devices using the investigated evaluation methods.
Secure Communication Based on a Hybrid of Chaos and Ica Encryptions
NASA Astrophysics Data System (ADS)
Chen, Wei Ching; Yuan, John
Chaos and independent component analysis (ICA) encryptions are two novel schemes for secure communications. In this paper, a new scheme combining chaos and ICA techniques is proposed to enhance the security level during communication. In this scheme, a master chaotic system is embedded at the transmitter. The message signal is mixed with a chaotic signal and a Gaussian white noise into two mixed signals and then transmitted to the receiver through the public channels. A signal for synchronization is transmitted through another public channel to the receiver where a slave chaotic system is embedded to reproduce the chaotic signal. A modified ICA is used to recover the message signal at the receiver. Since only two of the three transmitted signals contain the information of message signal, a hacker would not be able to retrieve the message signal by using ICA even though all the transmitted signals are intercepted. Spectrum analyses are used to prove that the message signal can be securely hidden under this scheme.
NASA Astrophysics Data System (ADS)
Klassen, Gerald A.; Paton, Barry E.; Maksym, Geoff; Janigan, David; Perey, Bernard
1992-08-01
Using a laser Doppler velocimeter (LDV) subcutaneous adipose tissue blood flow (AF) was recorded in the upright and supine positions in the upper and lower abdomen in 22 morbidly obese patients before gastroplasty. Age was 42 +/- 3 (mean +/- SEM), weight 135 +/- 7 kg, and body mass index (BMI) 51 +/- 3. Adipose flow expressed as mV was: supine, upper abdomen 647 +/- 23, lower abdomen 604 +/- 24; upright, upper abdomen 621 +/- 27, lower abdomen 607 +/- 29. AF was significantly more in the upper than lower abdomen (supine position) and AF was significantly lower in the lower abdomen upright than the upper abdomen supine. Regression analysis of age indicates that blood flow decreases in the lower abdomen so that in the supine position the difference between upper and lower abdomen AF increases. Similar analysis of BMI did not indicate significant trends. These data indicate that with morbid obesity there is lower tissue blood flow to the lower abdomen. This may explain why such patients may develop areas of painful ischemic necrosis in the dependent region of their anterior abdominal pannus.
Lee, ByungKun; Novais, Eduardo A.; Waheed, Nadia K.; Adhi, Mehreen; de Carlo, Talisa E.; Cole, Emily D.; Moult, Eric M.; Choi, WooJhon; Lane, Mark; Baumal, Caroline R.; Duker, Jay S.; Fujimoto, James G.
2018-01-01
IMPORTANCE Alterations in ocular blood flow play an important role in the pathogenesis and progression of diabetic retinopathy (DR). However, the measurement of retinal blood flow in clinical studies has been challenging. En face Doppler optical coherence tomography (OCT) provides an effective method for measuring total retinal blood flow (TRBF) in the clinic. OBJECTIVE To investigate TRBF in eyes with DR of varying severity, with or without diabetic macular edema (DME), using en face Doppler OCT. DESIGN, SETTING, AND PARTICIPANTS This was a cross-sectional study conducted from May 23, 2014, to January 11, 2016, which analyzed 41 eyes with DR from 31 diabetic patients, 20 eyes without DR from 11 diabetic patients, and 16 eyes from 12 healthy age-matched controls, all at the New England Eye Center in Boston, Massachusetts. MAIN OUTCOMES AND MEASURES Participants were imaged with a high-speed, swept-source OCT prototype at 1050-nm wavelength using repeated en face Doppler OCT raster scans, comprising 600 × 80 axial scans and covering a 1.5 × 2-mm2 area centered at the optic disc. The TRBF was automatically calculated using custom Matlab software. RESULTS This study included 41 eyes with DR from 31 diabetic patients (mean [SD] age, 62.8 [13.4] years; 12 were female patients), 20 eyes without DR from 11 diabetic patients (mean [SD] age, 58.8 [10.1] years; 5 were female patients), and 16 eyes from 12 healthy age-matched controls (mean [SD] age, 57.9 [8.1] years; 8 were female participants). The mean (SD) TRBF was 28.0 (8.5) μL/min in the eyes with DME, 48.8 (13.4) μL/min in the eyes with DR but without DME, 40.1 (7.7) μL/min in the diabetic eyes without retinopathy, and 44.4 (8.3) μL/min in age-matched healthy eyes. A difference in TRBF between the eyes with DME that were treated and the eyes with DME that were not treated was not identified. The TRBF was consistently low in the eyes with DME regardless of DR severity. The eyes with moderate nonproliferative DR
Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.
Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P
1995-01-01
Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.
Modeling and processing of laser Doppler reactive hyperaemia signals
NASA Astrophysics Data System (ADS)
Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre
2003-07-01
Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.
Orita, Erika; Murai, Yasuo; Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Ando, Takahiro; Iwata, Kotomi; Obara, Makoto; Kumita, Shinichiro
2018-05-11
The hemodynamic changes that occur after high-flow (extracranial-intracranial) EC-IC bypass surgery with internal carotid artery (ICA) ligation are not well known. To assess blood flow changes after high-flow EC-IC bypass with ICA ligation by time-resolved 3-dimensional phase-contrast (4D Flow) magnetic resonance imaging (MRI). We enrolled 11 patients who underwent high-flow EC-IC bypass. 4D Flow MRI was performed before and after surgery to quantify the blood flow volume (BFV) of the ipsilateral ICA (BFViICA), bypass artery (BFVbypass), contralateral ICA (BFVcICA), and basilar artery (BFVBA). Subsequently, we calculated the total BFV (BFVtotal = BFViICA + BFVcICA + BFVBA [before surgery], BFVcICA + BFVBA + BFVbypass [after surgery]). The BFV changes after bypass was statistically analyzed. BFVbypass was slightly lower than BFViICA, but the difference was not statistically significant (3.84 ± 0.94 vs 4.42 ± 1.38 mL/s). The BFVcICA and BFVBA significantly increased after bypass surgery (BFVcICA 5.89 ± 1.44 vs 7.22 ± 1.37 mL/s [P = .0018], BFVBA 3.06 ± 0.41 vs 4.12 ± 0.38 mL/s [P < .001]). The BFVtotal significantly increased after surgery (13.37 ± 2.58 vs 15.18 ± 1.77 mL/s [P = .015]). There was no evidence of hyperperfusion syndrome in any cases. After high-flow EC-IC bypass with permanent ICA ligation, the bypass artery could partially compensate for the loss of BFV of the sacrificed ICA. The increased flow of the contralateral ICA and BA supply collateral blood flow. Clinically irrelevant hyperperfusion was observed.
Neural spike sorting using iterative ICA and a deflation-based approach.
Tiganj, Z; Mboup, M
2012-12-01
We propose a spike sorting method for multi-channel recordings. When applied in neural recordings, the performance of the independent component analysis (ICA) algorithm is known to be limited, since the number of recording sites is much lower than the number of neurons. The proposed method uses an iterative application of ICA and a deflation technique in two nested loops. In each iteration of the external loop, the spiking activity of one neuron is singled out and then deflated from the recordings. The internal loop implements a sequence of ICA and sorting for removing the noise and all the spikes that are not fired by the targeted neuron. Then a final step is appended to the two nested loops in order to separate simultaneously fired spikes. We solve this problem by taking all possible pairs of the sorted neurons and apply ICA only on the segments of the signal during which at least one of the neurons in a given pair was active. We validate the performance of the proposed method on simulated recordings, but also on a specific type of real recordings: simultaneous extracellular-intracellular. We quantify the sorting results on the extracellular recordings for the spikes that come from the neurons recorded intracellularly. The results suggest that the proposed solution significantly improves the performance of ICA in spike sorting.
PREFACE: 7th International Conference on Applied Electrostatics (ICAES-2012)
NASA Astrophysics Data System (ADS)
Li, Jie
2013-03-01
ICAES is an important conference organized every four years by the Committee on Electrostatics of the Chinese Physical Society, which serves as a forum for scientists, educators and engineers interested in the fundamentals, applications, disasters and safety of electrostatics, etc. In recent years, new techniques, applications and fundamental theories on electrostatics have developed considerably. ICAES-7, held in Dalian, China, from 17-19 September 2012, aimed to provide a forum for all scholars to report the newest developments in electrostatics, to probe the questions that scholars faced and to discuss fresh ideas related to electrostatics. ICAES-7 was co-organized and hosted by Dalian University of Technology, and was sponsored by the Ministry of Education of China, the National Natural Science Foundation of China, Dalian University of Technology, Nanjing Suman Electronics Co. Ltd (Suman, China), Shekonic (Yangzhou Shuanghong, China) Electric/Mechanical Co. Ltd, and Suzhou TA&A Ultra Clean Technology Co. Ltd. (China). On behalf of the organizing committee of ICAES-7, I express my great appreciation for their support of the conference. Over 160 scholars and engineers from many countries including Croatia, The Czech Republic, D.P.R. Korea, Germany, Japan, Malaysia, Poland, Russia, the United States of America, China attended ICAES-7, and the conference collected and selected 149 papers for publication. The subjects of those papers cover the fundamentals of electrostatics, electrostatic disaster and safety, and electrostatic application (e.g. precipitation, pollutant control, biological treatment, mixture separation and food processing, etc). I cordially thank all authors and attendees for their support, and my appreciation is also given to the conference honorary chair, the organizing committee and advisory committee, and the conference secretaries for their hard work. ICAES-7 is dedicated to the memory of Professor Jen-Shih Chang (professor emeritus in the
Iwasaki, Wataru; Nogami, Hirofumi; Ito, Hiroki; Gotanda, Takeshi; Peng, Yao; Takeuchi, Satoshi; Furue, Masutaka; Higurashi, Eiji; Sawada, Renshi
2012-10-01
Alcohol has a variety of effects on the human body, affecting both the sympathetic and parasympathetic nervous system. We examined the peripheral blood flow of alcohol drinkers using a micro-integrated laser Doppler blood flow meter (micro-electromechanical system blood flow sensor). An increased heart rate and blood flow was recorded at the earlobe after alcohol ingestion, and we observed strong correlation between blood flow, heart rate, and breath alcohol content in light drinkers; but not heavy drinkers. We also found that the amplitude of pulse waves measured at the fingertip during an arm-raising test significantly decreased on alcohol consumption, regardless of the individual's alcohol tolerance. Our micro-electromechanical system blood flow sensor successfully detected various physiological changes in peripheral blood circulation induced by alcohol consumption.
The ICA Communication Audit: Process, Status, Critique
ERIC Educational Resources Information Center
Goldhaber, Gerald M.; Krivonos, Paul D.
1977-01-01
Explores the International Communication Association (ICA) Audit process including goals, products, instruments, audit logistics and timetable, feedback of results and follow-up, costs, current status and audits conducted to date. (ED.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyoden, Tomoaki, E-mail: kyouden@nc-toyama.ac.jp; Naruki, Shoji; Akiguchi, Shunsuke
Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensionalmore » space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.« less
Complex regression Doppler optical coherence tomography
NASA Astrophysics Data System (ADS)
Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.
2018-04-01
We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.
Krüger, Lars; Leidl, Stephanie; Bollwein, Heinrich
2013-01-01
Transrectal Doppler sonography was used to evaluate uterine blood flow during the first two weeks after parturition in six primiparous Simmental cows. The uterine blood flow was evaluated on the day of parturition (Day 0), once daily from Days 1 to 8 and then every other day until Day 14. Blood flow was quantified by determining the diameter (D), the time-averaged maximum velocity (TAMV), the pulsatility index (PI) and the blood flow volume (BFV) of the uterine arteries ipsilateral and contralateral to the formerly pregnant uterine horn. During the first four days after calving D, TAMV and BFV declined (ipsilateral: TAMV 70%, BFV 87%, contralateral: D 47%, BFV 84%; p < 0.05), while PI increased (ipsilateral 158%, contralateral 100%; p < 0.05) distinctly. Between Days 4 and 14 only the ipsilateral D (12%) and the BFV of both arteries (ipsilateral 5%, contralateral 8%) decreased (p < 0.05). Blood flow variables were very strongly correlated with each other (r > ±0.75, p < 0.05), with negative correlations with PI and positive correlations with all other investigated factors. Overall, this study revealed characteristic changes in uterine perfusion during the first two weeks after parturition in cows that were pronounced during the first four days postpartum. PMID:23820167
Heppelmann, Maike; Krüger, Lars; Leidl, Stephanie; Bollwein, Heinrich
2013-01-01
Transrectal Doppler sonography was used to evaluate uterine blood flow during the first two weeks after parturition in six primiparous Simmental cows. The uterine blood flow was evaluated on the day of parturition (Day 0), once daily from Days 1 to 8 and then every other day until Day 14. Blood flow was quantified by determining the diameter (D), the time-averaged maximum velocity (TAMV), the pulsatility index (PI) and the blood flow volume (BFV) of the uterine arteries ipsilateral and contralateral to the formerly pregnant uterine horn. During the first four days after calving D, TAMV and BFV declined (ipsilateral: TAMV 70%, BFV 87%, contralateral: D 47%, BFV 84%; p < 0.05), while PI increased (ipsilateral 158%, contralateral 100%; p < 0.05) distinctly. Between Days 4 and 14 only the ipsilateral D (12%) and the BFV of both arteries (ipsilateral 5%, contralateral 8%) decreased (p < 0.05). Blood flow variables were very strongly correlated with each other (r > ±0.75, p < 0.05), with negative correlations with PI and positive correlations with all other investigated factors. Overall, this study revealed characteristic changes in uterine perfusion during the first two weeks after parturition in cows that were pronounced during the first four days postpartum.
Performance Analysis of ICA in Sensor Array
Cai, Xin; Wang, Xiang; Huang, Zhitao; Wang, Fenghua
2016-01-01
As the best-known scheme in the field of Blind Source Separation (BSS), Independent Component Analysis (ICA) has been intensively used in various domains, including biomedical and acoustics applications, cooperative or non-cooperative communication, etc. While sensor arrays are involved in most of the applications, the influence on the performance of ICA of practical factors therein has not been sufficiently investigated yet. In this manuscript, the issue is researched by taking the typical antenna array as an illustrative example. Factors taken into consideration include the environment noise level, the properties of the array and that of the radiators. We analyze the analytic relationship between the noise variance, the source variance, the condition number of the mixing matrix and the optimal signal to interference-plus-noise ratio, as well as the relationship between the singularity of the mixing matrix and practical factors concerned. The situations where the mixing process turns (nearly) singular have been paid special attention to, since such circumstances are critical in applications. Results and conclusions obtained should be instructive when applying ICA algorithms on mixtures from sensor arrays. Moreover, an effective countermeasure against the cases of singular mixtures has been proposed, on the basis of previous analysis. Experiments validating the theoretical conclusions as well as the effectiveness of the proposed scheme have been included. PMID:27164100
Clustering-Constrained ICA for Ballistocardiogram Artifacts Removal in Simultaneous EEG-fMRI
Wang, Kai; Li, Wenjie; Dong, Li; Zou, Ling; Wang, Changming
2018-01-01
Combination of electroencephalogram (EEG) recording and functional magnetic resonance imaging (fMRI) plays a potential role in neuroimaging due to its high spatial and temporal resolution. However, EEG is easily influenced by ballistocardiogram (BCG) artifacts and may cause false identification of the related EEG features, such as epileptic spikes. There are many related methods to remove them, however, they do not consider the time-varying features of BCG artifacts. In this paper, a novel method using clustering algorithm to catch the BCG artifacts' features and together with the constrained ICA (ccICA) is proposed to remove the BCG artifacts. We first applied this method to the simulated data, which was constructed by adding the BCG artifacts to the EEG signal obtained from the conventional environment. Then, our method was tested to demonstrate the effectiveness during EEG and fMRI experiments on 10 healthy subjects. In simulated data analysis, the value of error in signal amplitude (Er) computed by ccICA method was lower than those from other methods including AAS, OBS, and cICA (p < 0.005). In vivo data analysis, the Improvement of Normalized Power Spectrum (INPS) calculated by ccICA method in all electrodes was much higher than AAS, OBS, and cICA methods (p < 0.005). We also used other evaluation index (e.g., power analysis) to compare our method with other traditional methods. In conclusion, our novel method successfully and effectively removed BCG artifacts in both simulated and vivo EEG data tests, showing the potentials of removing artifacts in EEG-fMRI applications. PMID:29487499
Directional connectivity of resting state human fMRI data using cascaded ICA-PDC analysis.
Silfverhuth, Minna J; Remes, Jukka; Starck, Tuomo; Nikkinen, Juha; Veijola, Juha; Tervonen, Osmo; Kiviniemi, Vesa
2011-11-01
Directional connectivity measures, such as partial directed coherence (PDC), give us means to explore effective connectivity in the human brain. By utilizing independent component analysis (ICA), the original data-set reduction was performed for further PDC analysis. To test this cascaded ICA-PDC approach in causality studies of human functional magnetic resonance imaging (fMRI) data. Resting state group data was imaged from 55 subjects using a 1.5 T scanner (TR 1800 ms, 250 volumes). Temporal concatenation group ICA in a probabilistic ICA and further repeatability runs (n = 200) were overtaken. The reduced data-set included the time series presentation of the following nine ICA components: secondary somatosensory cortex, inferior temporal gyrus, intracalcarine cortex, primary auditory cortex, amygdala, putamen and the frontal medial cortex, posterior cingulate cortex and precuneus, comprising the default mode network components. Re-normalized PDC (rPDC) values were computed to determine directional connectivity at the group level at each frequency. The integrative role was suggested for precuneus while the role of major divergence region may be proposed to primary auditory cortex and amygdala. This study demonstrates the potential of the cascaded ICA-PDC approach in directional connectivity studies of human fMRI.
Haverstick, Doris M; Brill, Louis B; Scott, Mitchell G; Bruns, David E
2009-05-01
Measurements of free (ionized) calcium (iCa) are increasingly requested in patient care locations where immediate analysis is unavailable. Evacuated blood collection tubes containing lithium heparin and gel separator material are widely used in clinical laboratories, but little information is available on the effects of these tubes or of delay prior to analysis on the concentration or stability of iCa. We collected blood from volunteers into lithium-heparin tubes (PST, Vacutainer PST, BD Pre-Analytic Systems) of multiple lots and into electrolyte-balanced heparin syringes (Portex Dry Heparin, Smiths Medical). iCa was measured (Siemens 1265 blood gas analyzers) immediately and, in PST, at 0-7 h with or without transportation of the tubes from remote sites. The mean difference of free calcium results in the PST tubes and electrolyte-balanced syringes was -0.08 (95% confidence interval -0.17 to 0.012) mmol/l, and the SD of the residuals (Sy, x) of the regression was 0.03 mmol/l. There was no detectable lot-to-lot variation in results. Free calcium was stable in tubes at room temperature and at 4 degrees C for at least 7 h with or without transportation. iCa measured in the examined blood collection tubes is stable and unaffected by lot-to-lot variation of tubes, but results are slightly lower than with special blood gas syringes.
Doppler ultrasound evaluation in preeclampsia
2013-01-01
Background Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. Results A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). Conclusion General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE. PMID:24252303
Removal of EMG and ECG artifacts from EEG based on wavelet transform and ICA.
Zhou, Weidong; Gotman, Jean
2004-01-01
In this study, the methods of wavelet threshold de-noising and independent component analysis (ICA) are introduced. ICA is a novel signal processing technique based on high order statistics, and is used to separate independent components from measurements. The extended ICA algorithm does not need to calculate the higher order statistics, converges fast, and can be used to separate subGaussian and superGaussian sources. A pre-whitening procedure is performed to de-correlate the mixed signals before extracting sources. The experimental results indicate the electromyogram (EMG) and electrocardiograph (ECG) artifacts in electroencephalograph (EEG) can be removed by a combination of wavelet threshold de-noising and ICA.
Association of multiple infarctions and ICAS with outcomes of minor stroke and TIA.
Pan, Yuesong; Meng, Xia; Jing, Jing; Li, Hao; Zhao, Xingquan; Liu, Liping; Wang, David; Johnston, S Claiborne; Wang, Yilong; Wang, Yongjun
2017-03-14
To estimate the association of different patterns of infarction and intracranial arterial stenosis (ICAS) with the prognosis of acute minor ischemic stroke and TIA. We derived data from the Clopidogrel in High-risk Patients with Acute Nondisabling Cerebrovascular Events (CHANCE) trial. A total of 1,089 patients from 45 of 114 participating sites of the trial undergoing baseline MRI/angiography were included in this subgroup analysis. Patterns of infarction and ICAS were recorded for each individual. The primary efficacy outcome was an ischemic stroke at the 90-day follow-up. We assessed the associations between imaging patterns and prognosis of patients using multivariable Cox regression models. Among the 1,089 patients included in this subgroup analysis, 93 (8.5%) patients had a recurrent ischemic stroke at 90 days. Compared with those without infarction or ICAS, patients with single infarction with ICAS (11.9% vs 1.3%, hazard ratio [HR] 6.25, 95% confidence intervals [CIs] 1.40-27.86, p = 0.02) and single infarction without ICAS (6.8% vs 1.3%, HR 4.65, 95% CI 1.05-20.64, p = 0.04) were all associated with an increased risk of ischemic stroke at 90 days. Patients with both multiple infarctions and ICAS were associated with approximately 13-fold risk of ischemic stroke at 90 days (18.0% vs 1.3%, HR 13.14, 95% CI 2.96-58.36, p < 0.001). The presence of multiple infarctions and ICAS were both associated with an increased risk of 90-day ischemic stroke in patients with minor stroke or TIA, while the presence of both imaging features had a combined effect. NCT00979589. © 2017 American Academy of Neurology.
An EEMD-ICA Approach to Enhancing Artifact Rejection for Noisy Multivariate Neural Data.
Zeng, Ke; Chen, Dan; Ouyang, Gaoxiang; Wang, Lizhe; Liu, Xianzeng; Li, Xiaoli
2016-06-01
As neural data are generally noisy, artifact rejection is crucial for data preprocessing. It has long been a grand research challenge for an approach which is able: 1) to remove the artifacts and 2) to avoid loss or disruption of the structural information at the same time, thus the risk of introducing bias to data interpretation may be minimized. In this study, an approach (namely EEMD-ICA) was proposed to first decompose multivariate neural data that are possibly noisy into intrinsic mode functions (IMFs) using ensemble empirical mode decomposition (EEMD). Independent component analysis (ICA) was then applied to the IMFs to separate the artifactual components. The approach was tested against the classical ICA and the automatic wavelet ICA (AWICA) methods, which were dominant methods for artifact rejection. In order to evaluate the effectiveness of the proposed approach in handling neural data possibly with intensive noises, experiments on artifact removal were performed using semi-simulated data mixed with a variety of noises. Experimental results indicate that the proposed approach continuously outperforms the counterparts in terms of both normalized mean square error (NMSE) and Structure SIMilarity (SSIM). The superiority becomes even greater with the decrease of SNR in all cases, e.g., SSIM of the EEMD-ICA can almost double that of AWICA and triple that of ICA. To further examine the potentials of the approach in sophisticated applications, the approach together with the counterparts were used to preprocess a real-life epileptic EEG with absence seizure. Experiments were carried out with the focus on characterizing the dynamics of the data after artifact rejection, i.e., distinguishing seizure-free, pre-seizure and seizure states. Using multi-scale permutation entropy to extract feature and linear discriminant analysis for classification, the EEMD-ICA performed the best for classifying the states (87.4%, about 4.1% and 8.7% higher than that of AWICA and ICA
Yao, Shengnan; Zeng, Weiming; Wang, Nizhuan; Chen, Lei
2013-07-01
Independent component analysis (ICA) has been proven to be effective for functional magnetic resonance imaging (fMRI) data analysis. However, ICA decomposition requires to optimize the unmixing matrix iteratively whose initial values are generated randomly. Thus the randomness of the initialization leads to different ICA decomposition results. Therefore, just one-time decomposition for fMRI data analysis is not usually reliable. Under this circumstance, several methods about repeated decompositions with ICA (RDICA) were proposed to reveal the stability of ICA decomposition. Although utilizing RDICA has achieved satisfying results in validating the performance of ICA decomposition, RDICA cost much computing time. To mitigate the problem, in this paper, we propose a method, named ATGP-ICA, to do the fMRI data analysis. This method generates fixed initial values with automatic target generation process (ATGP) instead of being produced randomly. We performed experimental tests on both hybrid data and fMRI data to indicate the effectiveness of the new method and made a performance comparison of the traditional one-time decomposition with ICA (ODICA), RDICA and ATGP-ICA. The proposed method demonstrated that it not only could eliminate the randomness of ICA decomposition, but also could save much computing time compared to RDICA. Furthermore, the ROC (Receiver Operating Characteristic) power analysis also denoted the better signal reconstruction performance of ATGP-ICA than that of RDICA. Copyright © 2013 Elsevier Inc. All rights reserved.
Effect of microbubble contrast on intracranial blood flow velocity assessed by transcranial Doppler.
Logallo, Nicola; Fromm, Annette; Waje-Andreassen, Ulrike; Thomassen, Lars; Matre, Knut
2014-03-01
Ultrasound contrast agents (UCA) salvage a considerable number of transcranial Doppler (TCD) exams which would have failed because of poor bone window. UCA bolus injection causes an undesirable increase in measured blood flow velocity (BFV). The effect of UCA continuous infusion on measured BFV has not been investigated, and some in vitro experiments suggest that gain reduction during UCA administration may also influence measured BFV. This study aimed to investigate the effect of UCA continuous infusion on BFV measured by TCD and the influence of gain reduction on these measurements in a clinical setting. The right middle cerebral artery of ten patients with optimal bone window was insonated using a 2 MHz probe. UCA were administered using an infusion pump. BFV was measured (1) at baseline, (2) during UCA infusion, (3) during UCA infusion with gain reduction, and (4) after UCA wash-out phase. Gain reduction was based on the agreement between two neurosonographers on the degree of gain reduction necessary to restore baseline Doppler signal intensity (DSI). Actual DSI was estimated offline by analysis of raw data. BFV measured during UCA infusion with no gain adjustment was significantly higher than baseline BFV [peak systolic velocity (PSV): 85.1 ± 19.7 vs. 74.4 ± 19.7 cm/s, p < 0.0001; Mean velocity (MV): 56.5 ± 11.8 vs. 50.2 ± 12.3 cm/s, p < 0.0001]. BFV measured during UCA infusion with gain reduction was not significantly higher than baseline BFV (PSV: 74.3 ± 18.9 vs. 74.4 ± 19.4 cm/s, p = 0.8; MV: 49.4 ± 11.0 vs. 50.2 ± 12.3 cm/s, p = 0.8). Actual DSI during UCA infusion with gain reduction was not significantly higher than baseline DSI (13 ± 1 vs. 13 ± 1 dB). This study shows that UCA continuous infusion leads to an increase in measured BFV which may be counteracted by reducing Doppler gain thus restoring pre-contrast DSI.
Hübsch, P J; Mostbeck, G; Barton, P P; Gritzmann, N; Fruehwald, F X; Schurawitzki, H; Kovarik, J
1990-02-01
One hundred one patients with renal allografts were studied by two independent observers using duplex Doppler sonography (DDS) and color-coded Doppler sonography (CCDS). In all patients, single or multiple percutaneous needle biopsies of the transplant had been performed 1 to 30 days before. In 6 patients CCDS following the biopsy demonstrated an area of combined red and blue color-coded blood flow within the renal parenchyma (n = 5) or within the sinus (n = 1); the Doppler waveform was abnormal in these areas with signals above and below the zero line indicating turbulent blood flow. Consecutive intraarterial digital subtraction angiography (DSA) revealed the presence of an arteriovenous fistula (n = 4) or of a pseudoaneurysm (n = 2). In one patient, gross hematuria with obstruction of the bladder occurred as a complication of a pseudoaneurysm within the renal sinus; the bleeding could not be stopped by embolization of the lesion and the kidney had to be removed. DDS demonstrated the lesion in only one of the six patients. Thus, CCDS is the method of choice for noninvasive detection of vascular lesions due to percutaneous biopsy.
New insight on the water management in Ica Valley-Peru
NASA Astrophysics Data System (ADS)
Guttman, Joseph; Berger, Diego
2014-05-01
The Andes divide Peru into three natural drainage basins: Pacific basin, Atlantic basin and Lake Titicaca basin. According to the National Water Authority (ANA), the Pacific basin is the driest basin. The bulk of water that feed the local aquifers in the coastal Pacific region is coming from rivers that flow west from the Andes. One of them is the Ica River- source of the Ica Aquifer and the Pampas de Villacuri Aquifer. The Ica River flows in a graben that was created by a series of faults. The graben is filled with sand and gravel with interbeded and lenses of clay. The aquifer thickness varies between 25 meters to more than 200 meters. The Ica Valley has an extension of 7700 km2 and belongs to the Province of Ica, the second larger economic center in Peru. The Valley is located in the hyperarid region of the Southern Coastal area of Peru with a few millimeters of precipitation per year. The direct recharge is almost zero. The recharge into the Ica Valley aquifer is comes indirectly by infiltration of storm water through the riverbed generates in the Andes, through irrigation canals and by irrigation return flow. In this hyperarid region, local aquifers like the Ica Valley are extremely valuable resources to local populations and are the key sources of groundwater for agriculture and population needs. Therefore, these aquifers play a crucial role in providing people with water and intense attention should be given to manage the water sector properly and to keep the aquifer sustainable for future generations. The total pumping (from rough estimations) is much greater than the direct and indirect recharge. The deficit in the water balance is reflected in large water level decline, out of operation of shallow wells and the ascending of saline water from deeper layers. The change from flood irrigation that contributes about 35-40% of the water to the aquifer, to drip irrigation dramatically reduces the amount of water that infiltrates into the sub-surface from the
A new fringeline-tracking approach for color Doppler ultrasound imaging phase unwrapping
NASA Astrophysics Data System (ADS)
Saad, Ashraf A.; Shapiro, Linda G.
2008-03-01
Color Doppler ultrasound imaging is a powerful non-invasive diagnostic tool for many clinical applications that involve examining the anatomy and hemodynamics of human blood vessels. These clinical applications include cardio-vascular diseases, obstetrics, and abdominal diseases. Since its commercial introduction in the early eighties, color Doppler ultrasound imaging has been used mainly as a qualitative tool with very little attempts to quantify its images. Many imaging artifacts hinder the quantification of the color Doppler images, the most important of which is the aliasing artifact that distorts the blood flow velocities measured by the color Doppler technique. In this work we will address the color Doppler aliasing problem and present a recovery methodology for the true flow velocities from the aliased ones. The problem is formulated as a 2D phase-unwrapping problem, which is a well-defined problem with solid theoretical foundations for other imaging domains, including synthetic aperture radar and magnetic resonance imaging. This paper documents the need for a phase unwrapping algorithm for use in color Doppler ultrasound image analysis. It describes a new phase-unwrapping algorithm that relies on the recently developed cutline detection approaches. The algorithm is novel in its use of heuristic information provided by the ultrasound imaging modality to guide the phase unwrapping process. Experiments have been performed on both in-vitro flow-phantom data and in-vivo human blood flow data. Both data types were acquired under a controlled acquisition protocol developed to minimize the distortion of the color Doppler data and hence to simplify the phase-unwrapping task. In addition to the qualitative assessment of the results, a quantitative assessment approach was developed to measure the success of the results. The results of our new algorithm have been compared on ultrasound data to those from other well-known algorithms, and it outperforms all of them.
A comparison of the wavelet and short-time fourier transforms for Doppler spectral analysis.
Zhang, Yufeng; Guo, Zhenyu; Wang, Weilian; He, Side; Lee, Ting; Loew, Murray
2003-09-01
Doppler spectrum analysis provides a non-invasive means to measure blood flow velocity and to diagnose arterial occlusive disease. The time-frequency representation of the Doppler blood flow signal is normally computed by using the short-time Fourier transform (STFT). This transform requires stationarity of the signal during a finite time interval, and thus imposes some constraints on the representation estimate. In addition, the STFT has a fixed time-frequency window, making it inaccurate to analyze signals having relatively wide bandwidths that change rapidly with time. In the present study, wavelet transform (WT), having a flexible time-frequency window, was used to investigate its advantages and limitations for the analysis of the Doppler blood flow signal. Representations computed using the WT with a modified Morlet wavelet were investigated and compared with the theoretical representation and those computed using the STFT with a Gaussian window. The time and frequency resolutions of these two approaches were compared. Three indices, the normalized root-mean-squared errors of the minimum, the maximum and the mean frequency waveforms, were used to evaluate the performance of the WT. Results showed that the WT can not only be used as an alternative signal processing tool to the STFT for Doppler blood flow signals, but can also generate a time-frequency representation with better resolution than the STFT. In addition, the WT method can provide both satisfactory mean frequencies and maximum frequencies. This technique is expected to be useful for the analysis of Doppler blood flow signals to quantify arterial stenoses.
Quantitative analysis of skin flap blood flow in the rat using laser Doppler velocimetry.
Marks, N J
1985-01-01
Two experiments carried out on rat skin flaps are described, where microvascular flow has been measured noninvasively by a laser Doppler velocimeter. Using this technique it is possible to define the limits of an axial pattern flap in terms of microvascular flow; this was found to increase when the flap is elevated. 'Random-pattern' perfusion is defined by a fall in flow. This recovers sequentially along the flap, and at a constant rate at all sites. A differential in microvascular perfusion is thus maintained along a random-pattern flap for at least the first postoperative week. In a second experiment it is shown that there appears to be a linear relationship between the reduction in skin blood flow in a random-pattern flap and the distance from the base at which the measurements are made. It is suggested that these data support the view that the blood flow in a skin flap recovers primarily from its base rather than via peripheral neovascularization, and that this is due to vascular collaterals opening within the flap rather than to a relaxation of sympathetic tone. PMID:3156992
Vergara, Victor M; Ulloa, Alvaro; Calhoun, Vince D; Boutte, David; Chen, Jiayu; Liu, Jingyu
2014-09-01
Multi-modal data analysis techniques, such as the Parallel Independent Component Analysis (pICA), are essential in neuroscience, medical imaging and genetic studies. The pICA algorithm allows the simultaneous decomposition of up to two data modalities achieving better performance than separate ICA decompositions and enabling the discovery of links between modalities. However, advances in data acquisition techniques facilitate the collection of more than two data modalities from each subject. Examples of commonly measured modalities include genetic information, structural magnetic resonance imaging (MRI) and functional MRI. In order to take full advantage of the available data, this work extends the pICA approach to incorporate three modalities in one comprehensive analysis. Simulations demonstrate the three-way pICA performance in identifying pairwise links between modalities and estimating independent components which more closely resemble the true sources than components found by pICA or separate ICA analyses. In addition, the three-way pICA algorithm is applied to real experimental data obtained from a study that investigate genetic effects on alcohol dependence. Considered data modalities include functional MRI (contrast images during alcohol exposure paradigm), gray matter concentration images from structural MRI and genetic single nucleotide polymorphism (SNP). The three-way pICA approach identified links between a SNP component (pointing to brain function and mental disorder associated genes, including BDNF, GRIN2B and NRG1), a functional component related to increased activation in the precuneus area, and a gray matter component comprising part of the default mode network and the caudate. Although such findings need further verification, the simulation and in-vivo results validate the three-way pICA algorithm presented here as a useful tool in biomedical data fusion applications. Copyright © 2014 Elsevier Inc. All rights reserved.
Doppler ultrasound of the central retinal artery in microgravity.
Sirek, Adam S; Garcia, Kathleen; Foy, Millennia; Ebert, Doug; Sargsyan, Ashot; Wu, Jimmy H; Dulchavsky, Scott A
2014-01-01
Ocular changes have been noted during long-duration spaceflight; we studied central retinal artery (CRA) blood flow using Doppler before, during, and after long-term microgravity exposure in astronauts compared with data from a control group of nonastronauts subjected to head-down tilt (HDT). Available Doppler spectra of International Space Station (ISS) crewmembers were obtained from the NASA Lifetime Surveillance of Astronaut Health database, along with 2D ultrasound-derived measurements of the optic nerve sheath diameter (ONSD). CRA Doppler spectra and optic nerve sheath images were also obtained from healthy test subjects in an acute HDT experiment at 20 min of exposure (the ground-based analogue). HDT CRA peak systolic velocity in the ground-based analogue group increased by an average of 3 cm -s(-1) (33%) relative to seated values. ONSD at 300 of HDT increased by 0.5 mm relative to supine values. CRA Doppler spectra obtained on orbit were of excellent quality and demonstrated in-flight changes of +5 cm x s(-1) (50%) compared to preflight. ONSD increased in ISS crewmembers during flight relative to before flight, with some reversal postflight. A significant ONSD response to acute postural change and to spaceflight was demonstrated in this preliminary study. Increases in Doppler peak flow velocities correlated with increases in ONSD. Further investigations are warranted to corroborate the relationship between ONSD, intracranial pressure, and central retinal blood flow for occupational surveillance and research purposes.
Evaluating Internal Communication: The ICA Communication Audit.
ERIC Educational Resources Information Center
Goldhaber, Gerald M.
1978-01-01
The ICA Communication Audit is described in detail as an effective measurement procedure that can help an academic institution to evaluate its internal communication system. Tools, computer programs, analysis, and feedback procedures are described and illustrated. (JMF)
Laser Doppler imaging of genital blood flow: a direct measure of female sexual arousal.
Waxman, Samantha E; Pukall, Caroline F
2009-08-01
Female sexual arousal is a challenging construct to measure, partly because of the subtle nature of its indicators, vaginal lubrication and genital swelling. As a result, many instruments have been used in an attempt to accurately measure it; however, problems are associated with each. Furthermore, the relationship between subjective and physiological indicators of arousal appears to be influenced by the instrument used to measure physiological arousal. Specifically, instruments measuring physiological arousal internally yield lower correlations between measures of physiological and subjective arousal than instruments examining the external genitals. Laser Doppler imaging (LDI) is a direct measure of external genital blood flow. The purpose of this study was to investigate the usefulness of LDI for measuring genital blood flow in women in response to erotic visual stimuli, and to explore the relationship between physiological and subjective sexual arousal. Sixty-five participants watched three 15-minute films during LDI scanning. Two nature films (measuring acclimatization and baseline blood flow levels) and one randomly assigned experimental film (erotic, anxiety, humor, or neutral) were used. Participants rated their level of subjective arousal following the third film. Results indicated a significant effect of film condition on genital blood flow, P < 0.001, with the erotic condition differing significantly from the other three conditions. In terms of the relationship between physiological and subjective sexual arousal, physiological arousal was significantly predicted by subjective ratings of sexual arousal (P < 0.001). LDI appears to be able to differentiate blood flow during erotic and nonerotic conditions. In addition, physiological sexual arousal was significantly predicted by women's reported subjective sexual arousal. These findings suggest that LDI is a useful instrument for measuring female sexual arousal, and that women may be more aware of their level
A comparison of PCA/ICA for data preprocessing in remote sensing imagery classification
NASA Astrophysics Data System (ADS)
He, Hui; Yu, Xianchuan
2005-10-01
In this paper a performance comparison of a variety of data preprocessing algorithms in remote sensing image classification is presented. These selected algorithms are principal component analysis (PCA) and three different independent component analyses, ICA (Fast-ICA (Aapo Hyvarinen, 1999), Kernel-ICA (KCCA and KGV (Bach & Jordan, 2002), EFFICA (Aiyou Chen & Peter Bickel, 2003). These algorithms were applied to a remote sensing imagery (1600×1197), obtained from Shunyi, Beijing. For classification, a MLC method is used for the raw and preprocessed data. The results show that classification with the preprocessed data have more confident results than that with raw data and among the preprocessing algorithms, ICA algorithms improve on PCA and EFFICA performs better than the others. The convergence of these ICA algorithms (for data points more than a million) are also studied, the result shows EFFICA converges much faster than the others. Furthermore, because EFFICA is a one-step maximum likelihood estimate (MLE) which reaches asymptotic Fisher efficiency (EFFICA), it computers quite small so that its demand of memory come down greatly, which settled the "out of memory" problem occurred in the other algorithms.
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP.
Winkler, Irene; Debener, Stefan; Müller, Klaus-Robert; Tangermann, Michael
2015-01-01
Standard artifact removal methods for electroencephalographic (EEG) signals are either based on Independent Component Analysis (ICA) or they regress out ocular activity measured at electrooculogram (EOG) channels. Successful ICA-based artifact reduction relies on suitable pre-processing. Here we systematically evaluate the effects of high-pass filtering at different frequencies. Offline analyses were based on event-related potential data from 21 participants performing a standard auditory oddball task and an automatic artifactual component classifier method (MARA). As a pre-processing step for ICA, high-pass filtering between 1-2 Hz consistently produced good results in terms of signal-to-noise ratio (SNR), single-trial classification accuracy and the percentage of `near-dipolar' ICA components. Relative to no artifact reduction, ICA-based artifact removal significantly improved SNR and classification accuracy. This was not the case for a regression-based approach to remove EOG artifacts.
Kijsamanmith, Kanittha; Timpawat, Siriporn; Vongsavan, Noppakun; Matthews, Bruce
2011-06-01
To compare red (635 nm) and infrared (780 nm) light for recording pulpal blood flow from human anterior teeth with a laser Doppler flow meter. Recordings were made from 7 healthy teeth in 5 subjects (aged 22-55 years) using a laser Doppler flow meter (Periflux 4001) equipped with both red and infrared lasers. Average blood flow signals were obtained with both light sources alternately from each tooth under five conditions: intact tooth without opaque rubber dam, intact tooth with dam, after injecting local anaesthetic (3% Mepivacaine) (LA) over the apex of the tooth and cavity preparation to almost expose the pulp, after removal and replacement of the pulp, and with the root canal empty. With infrared light, because of technical limitations, data were obtained for the first three conditions only. The dam significantly decreased the mean blood flow by 82%. Injecting LA and cavity preparation had no significant effect. With red light, dam produced a decrease of 56%, and the resulting signal was reduced by 33% after LA and cavity preparation. The remaining signal fell by 46% after pulp removal and replacement. This contribution of the pulp is similar to that recorded previously with infrared light. There was no significant further change when the pulp was finally removed. The importance of using opaque rubber dam is confirmed. With dam, there is no advantage to using red rather than infrared light, and in each case the pulp contributes less than 50% to the blood flow signal. Copyright © 2011 Elsevier Ltd. All rights reserved.
El-Sayed, Mohamed Adel; Saleh, Said Abdel-Aty; Maher, Mohammad Ahmed; Khidre, Asmaa Mohamed
2018-04-01
To assess efficacy and tolerability of sildenafil citrate on utero-placental blood flow and fetal growth in pregnancies complicated by fetal growth restriction (FGR). From March 2015, a randomized controlled trial of 54 patients at 24 weeks or more complicated by FGR and abnormal Doppler indices were randomly allocated 1:1 into an intervention arm (receive sildenafil citrate, 50 mg) or a control arm (receive placebo). The primary outcomes were changes occurred in the Doppler parameters 2 h following drug administration. Baseline characteristics were similar between groups. Significant difference was observed in the Delta uterine and umbilical Doppler indices among sildenafil group as compared to placebo group (p < 0.001). Middle cerebral Doppler indices, however, decreased significantly after sildenafil, which could be the result of shifting more blood to improve the utero-placental perfusion. No difference regarding Delta cerebro-placental ratio among both groups (p = 0.979). Sildenafil was also associated with pregnancy prolongation (p = .0001), increased gestational age at delivery (p = .004), improved neonatal weight (p = .0001), and less admission to neonatal intensive care unit (p = .03). No adverse effects reported in both treatment arms. Sildenafil citrate, by its vasodilator effect, can improve utero-placental blood flow in pregnancies complicated by FGR and abnormal Doppler. gov Registry: NCT02362399.
Hussein, Hassan A
2013-04-15
The aim of this study was to verify the efficacy of color Doppler ultrasonography for diagnosis of degree and duration of uterine torsion in buffaloes. In Assiut province/Upper Egypt, 65 buffaloes (37 with uterine torsion, 28 with normal late pregnancy) were examined clinically and using Doppler ultrasonography. The Doppler indices including resistance index (RI), pulsatility index (PI), time-averaged maximum velocity (TAMV), and blood flow volume (BFV) in the arteries ipsilateral to the uterine torsion (IPUT) and in arteries contralateral to the uterine torsion (COUT) were recorded. Methods of correction were documented along with dam and calf survival. Torsion was recorded postcervically with vaginal involvement in 35/37 (94.6%) of the cases. The degrees of uterine torsion were light and high in 9/37 (24.3%) and 28/37 (75.7%) of the cases, respectively (P = 0.001). Right uterine torsion was present in 36/37 (97.3%) of the cases (P = 0.0001). Pulsatility index, RI, TAMV, and BFV in IPUT and COUT did not differ significantly (P > 0.05) in normal late pregnancy. The PI and RI in IPUT were significantly higher (P < 0.01) than in COUT, and the TAMV and BFV in IPUT were less (P < 0.001) than that in COUT in uterine torsion. The PI and RI of torsion cases in IPUT were higher (P < 0.001) than that in normal pregnancy. Time-averaged maximum velocity and BFV in torsion cases were lower (P < 0.01) than that of normal pregnancy in IPUT. There was approximately 50% of RI and PI higher than in light degree uterine torsion in IPUT (P < 0.001). Consequently, TAMV and BFV were greatly lower (P < 0.0001) than that in light degree in IPUT. Pulsatility index and RI were positively correlated (r = 0.856; P < 0.001) with the duration and degree of the uterine torsion, and TAMV and BFV were negatively correlated (r = -0.763; P < 0.001). In all cases of uterine torsion the uterine flow velocity waveform showed high systolic flow and absence of early diastolic flow and poor uterine and
1979-12-28
Doppler sound made by a bubble passing through the inson- ified volume blood vessel resembles a very sharp truncated whistle , chirp or click depending...the Doppler ultrasound , suffered the "slings and arrows of outrageous criticism" to borrow and beat a phrase. It is not appropriate to go into this
Sui, Jing; Adali, Tülay; Pearlson, Godfrey D.; Clark, Vincent P.; Calhoun, Vince D.
2009-01-01
Independent component analysis (ICA) is a promising method that is increasingly used to analyze brain imaging data such as functional magnetic resonance imaging (fMRI), structural MRI, and electroencephalography and has also proved useful for group comparison, e.g., differentiating healthy controls from patients. An advantage of ICA is its ability to identify components that are mixed in an unknown manner. However, ICA is not necessarily robust and optimal in identifying between-group effects, especially in highly noisy situations. Here, we propose a modified ICA framework for multi-group data analysis that incorporates prior information regarding group membership as a constraint into the mixing coefficients. Our approach, called coefficient-constrained ICA (CC-ICA), prioritizes identification of components that show a significant group difference. The performance of CC-ICA via synthetic and hybrid data simulations is evaluated under different hypothesis testing assumptions and signal to noise ratios (SNRs). Group analysis is also conducted on real multitask fMRI data. Results show that CC-ICA improves the estimation accuracy of the independent components greatly, especially those that have different patterns for different groups (e.g., patients vs. controls); In addition, it enhances the data extraction sensitivity to group differences by ranking components with P value or J-divergence more consistently with the ground truth. The proposed algorithm performs quite well for both group-difference detection and multitask fMRI data fusion, which may prove especially important for the identification of relevant disease biomarkers. PMID:19172631
[Color Doppler ultrasonography--a new imaging procedure in maxillofacial surgery].
Reinert, S; Lentrodt, J
1991-01-01
Colour Doppler ultrasonography shows blood flow in real time and colour by combining the features of real time B mode ultrasound and Doppler. At each point in the image the returning signal is interrogated for both amplitude and frequency information. The resulting image shows all non-moving structures in shades of gray and moving structures in shades of red or blue depending on direction and velocity. The technique of colour Doppler ultrasonography and our experiences in 63 examinations are described. The clinical application of this new simple non-invasive method in maxillo-facial surgery is discussed.
Doppler ultrasound exam of an arm or leg
... page: //medlineplus.gov/ency/article/003775.htm Doppler ultrasound exam of an arm or leg To use ... this page, please enable JavaScript. This test uses ultrasound to look at the blood flow in the ...
NASA Astrophysics Data System (ADS)
Desjardins, Candida L.; Antonelli, Lynn T.; Soares, Edward
2007-02-01
The use of lasers to remotely and non-invasively detect the blood pressure waveform of humans and animals would provide a powerful diagnostic tool. Current blood pressure measurement tools, such as a cuff, are not useful for burn and trauma victims, and animals require catheterization to acquire accurate blood pressure information. The purpose of our sensor method and apparatus invention is to remotely and non-invasively detect the blood pulse waveform of both animals and humans. This device is used to monitor an animal or human's skin in proximity to an artery using radiation from a laser Doppler vibrometer (LDV). This system measures the velocity (or displacement) of the pulsatile motion of the skin, indicative of physiological parameters of the arterial motion in relation to the cardiac cycle. Tests have been conducted that measures surface velocity with an LDV and a signal-processing unit, with enhanced detection obtained with optional hardware including a retro-reflector dot. The blood pulse waveform is obtained by integrating the velocity signal to get surface displacement using standard signal processing techniques. Continuous recording of the blood pulse waveform yields data containing information on cardiac health and can be analyzed to identify important events in the cardiac cycle, such as heart rate, the timing of peak systole, left ventricular ejection time and aortic valve closure. Experimental results are provided that demonstrates the current capabilities of the optical, non-contact sensor for the continuous, non-contact recording of the blood pulse waveform without causing patient distress.
Bishai, John M; Blood, Arlin B; Hunter, Christian J; Longo, Lawrence D; Power, Gordon G
2003-01-01
This study was undertaken to compare microsphere and laser Doppler flowmetry techniques for the measurement of cerebral blood flow, to assess the effect of probe implantation at the tip of the sensing probe and to measure brain tissue PO2 (tPO2) in response to acute hypoxia. Fetal sheep of ≈131 days gestation (n = 8) were chronically instrumented with bilateral laser Doppler probes in the parietal cortices and catheters for injection of fluorescent microspheres. Five days after surgery fetuses were subjected to 1 h periods of baseline control breathing, hypoxia and recovery. Microspheres were injected 10 min prior to and 10, 30, 50 and 120 min after initiation of hypoxia. Microspheres were counted in four 12 mm3 tissue samples from each hemisphere, the tip of the laser Doppler probe being positioned in the centre of one of the cubes. The cube containing the probe tip was also subdivided into 4 mm3 pieces of tissue. In response to hypoxia, fetal arterial PO2 declined from 21 ± 2 to 12 ± 1 Torr and brain tissue PO2 fell from 10 ± 1 to a nadir of 1 ± 1 Torr. Each method detected a significant increase in CBF that reached a maximum after 30–45 min, although the increase of flow measured by laser Doppler flowmetry was less than that measured by spheres after 10 and 30 min (P < 0.05). Microspheres did not detect altered flow at the probe tip or heterogeneity of flow in surrounding volumes of cortical tissue. In summary, laser Doppler flowmetry is a useful measure of continuous relative changes of CBF in the chronically instrumented fetal sheep. Flow compensations in acute hypoxia are not adequate to sustain O2 delivery, and other compensations, including reduced metabolic rate, are possible. PMID:12563011
Recurrence of ICA-PCoA aneurysms after neck clipping.
Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S
1994-01-01
Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.
An 81.6 μW FastICA processor for epileptic seizure detection.
Yang, Chia-Hsiang; Shih, Yi-Hsin; Chiueh, Herming
2015-02-01
To improve the performance of epileptic seizure detection, independent component analysis (ICA) is applied to multi-channel signals to separate artifacts and signals of interest. FastICA is an efficient algorithm to compute ICA. To reduce the energy dissipation, eigenvalue decomposition (EVD) is utilized in the preprocessing stage to reduce the convergence time of iterative calculation of ICA components. EVD is computed efficiently through an array structure of processing elements running in parallel. Area-efficient EVD architecture is realized by leveraging the approximate Jacobi algorithm, leading to a 77.2% area reduction. By choosing proper memory element and reduced wordlength, the power and area of storage memory are reduced by 95.6% and 51.7%, respectively. The chip area is minimized through fixed-point implementation and architectural transformations. Given a latency constraint of 0.1 s, an 86.5% area reduction is achieved compared to the direct-mapped architecture. Fabricated in 90 nm CMOS, the core area of the chip is 0.40 mm(2). The FastICA processor, part of an integrated epileptic control SoC, dissipates 81.6 μW at 0.32 V. The computation delay of a frame of 256 samples for 8 channels is 84.2 ms. Compared to prior work, 0.5% power dissipation, 26.7% silicon area, and 3.4 × computation speedup are achieved. The performance of the chip was verified by human dataset.
Secchi, M E; Sulli, A; Pizzorni, C; Cutolo, M
2009-01-01
Systemic sclerosis (SSc) is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC) is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF) can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blood flow in SSc. Twenty-seven SSc patients and 12 healthy subjects were enrolled. SSc microvascular involvement, as evaluated by NVC, was classified in three different patterns ("Early", "Active", "Late"). LDF analysis was performed at the II, III, IV, V hand fingers in both hands and both at cutaneous temperature and at 36 degrees C. Statistical evaluation was carried out by non-parametric procedures. Blood flow was found significantly lower in SSc patients when compared with healthy subjects (p<0.05). The heating of the probe to 36 degrees C induced a significant increase in peripheral blood flow in all subjects compared to baseline (p <0.05), however, the amount of variation was significantly lower in patients with SSc, compared with healthy controls (p <0.05). The SSc patients with NVC "Late" pattern, showed lower values of peripheral blood flow than patients with NVC "Active" or "Early" patterns (p<0.05). Moreover, a negative correlation between the tissue perfusion score and the progression of the SSc microangiopathy was observed, as well as between the tissue perfusion and the duration of the Raynaud's phenomenon (p <0.03). LDF can be employed to evaluate blood perfusion in the microvascular circulation in SSc patients. The blood flow changes observed with the LDF seem to correlate with the severity of microvascular damage in SSc as detected by NVC.
Lantsberg, L; Goldman, M
1991-04-01
The level of amputation continues to present a challenge for surgeons. In view of this, 24 patients who required an amputation of their ischaemic leg were studied prospectively using Laser Doppler flowmetry (LDF), TcpO2 measurements and Doppler ultrasound to assess the best level for amputation. In all patients gangrene of the leg and rest pain were the indication for an amputation. Skin oxygen tension (TcpO2) and skin blood flow (LDF) measurements were obtained the day before surgery on the proposed anterior and posterior skin flaps for below knee amputation and the maximum Doppler systolic pressure was measured. The level of amputation was chosen at surgery by clinical judgement without reference to the measurements mentioned above. A below knee amputation was performed in 17 patients and an above knee in seven. All amputations healed by primary intention. Doppler pressures showed poor discrimination with a median value of 10 mmHg (0-25) in AK patients and 35 mmHg (0-85) in the BK group (p greater than 0.05). In contrast TcpO2 showed a trend. In the BK group the median value was 20 mmHg (4-50) on the anterior and 22 mmHg (2-60) on the posterior flap compared to above knee amputees with median values of 6 mmHg (2-11) and 8 mmHg (3-38), respectively (p greater than 0.05). Laser Doppler seemed more useful. In BK patients the median LDF values were 36 mV (20-85) on the anterior and 34 mV (20-80) on the posterior flap with median LDF values of 10 mV (10-18) on the anterior and 11 mV (8-38) on the posterior flap in the above knee group (p less than 0.01). Laser Doppler flowmetry is a simple objective test, which is a better discriminator of skin flap perfusion than either TcpO2 or Doppler ankle pressures.
Design of FPGA ICA for hyperspectral imaging processing
NASA Astrophysics Data System (ADS)
Nordin, Anis; Hsu, Charles C.; Szu, Harold H.
2001-03-01
The remote sensing problem which uses hyperspectral imaging can be transformed into a blind source separation problem. Using this model, hyperspectral imagery can be de-mixed into sub-pixel spectra which indicate the different material present in the pixel. This can be further used to deduce areas which contain forest, water or biomass, without even knowing the sources which constitute the image. This form of remote sensing allows previously blurred images to show the specific terrain involved in that region. The blind source separation problem can be implemented using an Independent Component Analysis algorithm. The ICA Algorithm has previously been successfully implemented using software packages such as MATLAB, which has a downloadable version of FastICA. The challenge now lies in implementing it in a form of hardware, or firmware in order to improve its computational speed. Hardware implementation also solves insufficient memory problem encountered by software packages like MATLAB when employing ICA for high resolution images and a large number of channels. Here, a pipelined solution of the firmware, realized using FPGAs are drawn out and simulated using C. Since C code can be translated into HDLs or be used directly on the FPGAs, it can be used to simulate its actual implementation in hardware. The simulated results of the program is presented here, where seven channels are used to model the 200 different channels involved in hyperspectral imaging.
NASA Astrophysics Data System (ADS)
Ghaffarian, Saman; Ghaffarian, Salar
2014-11-01
This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.
Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment
NASA Astrophysics Data System (ADS)
Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin
2013-06-01
This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (p<0.001). After 14 days for the Er:YAG area the blood perfusion returned to the initial value. The results in diode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.
The laser Doppler flowmeter for measuring microcirculation in human nasal mucosa.
Olsson, P; Bende, M; Ohlin, P
1985-01-01
A new technique, based on the laser doppler principle, for measuring nasal mucosal microcirculation in humans, is presented. With this technique the relation between the blood flow and the temperature of the nasal mucosa was evaluated in healthy subjects exposed to peripheral cold stimulus. A decrease in blood flow and in mucosal temperature was found in all subjects when the feet were exposed to cold water for 5 min. The decrease in blood flow occurred almost momentarily and was restored to normal within the 5 min of exposure, while the drop in mucosal temperature was more gradual and persisted for a longer time. The implication of this study is that the laser doppler flowmeter seems to be a useful tool for estimation of changes in nasal mucosal microcirculation.
Mannan, Malik M Naeem; Jeong, Myung Y; Kamran, Muhammad A
2016-01-01
Electroencephalography (EEG) is a portable brain-imaging technique with the advantage of high-temporal resolution that can be used to record electrical activity of the brain. However, it is difficult to analyze EEG signals due to the contamination of ocular artifacts, and which potentially results in misleading conclusions. Also, it is a proven fact that the contamination of ocular artifacts cause to reduce the classification accuracy of a brain-computer interface (BCI). It is therefore very important to remove/reduce these artifacts before the analysis of EEG signals for applications like BCI. In this paper, a hybrid framework that combines independent component analysis (ICA), regression and high-order statistics has been proposed to identify and eliminate artifactual activities from EEG data. We used simulated, experimental and standard EEG signals to evaluate and analyze the effectiveness of the proposed method. Results demonstrate that the proposed method can effectively remove ocular artifacts as well as it can preserve the neuronal signals present in EEG data. A comparison with four methods from literature namely ICA, regression analysis, wavelet-ICA (wICA), and regression-ICA (REGICA) confirms the significantly enhanced performance and effectiveness of the proposed method for removal of ocular activities from EEG, in terms of lower mean square error and mean absolute error values and higher mutual information between reconstructed and original EEG.
Transcutaneous measurement of volume blood flow
NASA Technical Reports Server (NTRS)
Daigle, R. E.; Mcleod, F. D.; Miller, C. W.; Histand, M. B.; Wells, M. K.
1974-01-01
Blood flow velocity measurements, using Doppler velocimeter, are described. The ability to measure blood velocity using ultrasound is derived from the Doppler effect; the change in frequency which occurs when sound is reflected or transmitted from a moving target. When ultrasound of the appropriate frequency is transmitted through a moving blood stream, the blood cells act as point scatterers of ultrasonic energy. If this scattered ultrasonic energy is detected, it is found to be shifted in frequency according to the velocity of the blood cells, nu, the frequency of the incident sound, f sub o, the speed of sound in the medium, c, and the angle between the sound beam and the velocity vector, o. The relation describing this effect is known as the Doppler equation. Delta f = 2 f sub o x nu x cos alpha/c. The theoretical and experimental methods are evaluated.
Spatiotemporal patterns of ERP based on combined ICA-LORETA analysis
NASA Astrophysics Data System (ADS)
Zhang, Jiacai; Guo, Taomei; Xu, Yaqin; Zhao, Xiaojie; Yao, Li
2007-03-01
In contrast to the FMRI methods widely used up to now, this method try to understand more profoundly how the brain systems work under sentence processing task map accurately the spatiotemporal patterns of activity of the large neuronal populations in the human brain from the analysis of ERP data recorded on the brain scalp. In this study, an event-related brain potential (ERP) paradigm to record the on-line responses to the processing of sentences is chosen as an example. In order to give attention to both utilizing the ERPs' temporal resolution of milliseconds and overcoming the insensibility of cerebral location ERP sources, we separate these sources in space and time based on a combined method of independent component analysis (ICA) and low-resolution tomography (LORETA) algorithms. ICA blindly separate the input ERP data into a sum of temporally independent and spatially fixed components arising from distinct or overlapping brain or extra-brain sources. And then the spatial maps associated with each ICA component are analyzed, with use of LORETA to uniquely locate its cerebral sources throughout the full brain according to the assumption that neighboring neurons are simultaneously and synchronously activated. Our results show that the cerebral computation mechanism underlies content words reading is mediated by the orchestrated activity of several spatially distributed brain sources located in the temporal, frontal, and parietal areas, and activate at distinct time intervals and are grouped into different statistically independent components. Thus ICA-LORETA analysis provides an encouraging and effective method to study brain dynamics from ERP.
Evaluating the efficacy of fully automated approaches for the selection of eye blink ICA components
Pontifex, Matthew B.; Miskovic, Vladimir; Laszlo, Sarah
2017-01-01
Independent component analysis (ICA) offers a powerful approach for the isolation and removal of eye blink artifacts from EEG signals. Manual identification of the eye blink ICA component by inspection of scalp map projections, however, is prone to error, particularly when non-artifactual components exhibit topographic distributions similar to the blink. The aim of the present investigation was to determine the extent to which automated approaches for selecting eye blink related ICA components could be utilized to replace manual selection. We evaluated popular blink selection methods relying on spatial features [EyeCatch()], combined stereotypical spatial and temporal features [ADJUST()], and a novel method relying on time-series features alone [icablinkmetrics()] using both simulated and real EEG data. The results of this investigation suggest that all three methods of automatic component selection are able to accurately identify eye blink related ICA components at or above the level of trained human observers. However, icablinkmetrics(), in particular, appears to provide an effective means of automating ICA artifact rejection while at the same time eliminating human errors inevitable during manual component selection and false positive component identifications common in other automated approaches. Based upon these findings, best practices for 1) identifying artifactual components via automated means and 2) reducing the accidental removal of signal-related ICA components are discussed. PMID:28191627
NASA Astrophysics Data System (ADS)
Ruiz, Michael J.; Abee, Jeremy
2006-10-01
In this paper we present a design for a Doppler football. The classic Doppler ball uses a piezo buzzer and 9-V battery inside a foam ball. In our Doppler football, the sound level is enhanced by directing the 2.8-kHz tone of the buzzer through a hollow cylinder to one end of the football, with an on-off switch placed at the other end. We discuss our device within the historical context of Doppler demonstrations that have evolved over the many decades since Doppler's discovery.
Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U
2017-04-01
Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p < 0.001), in TAMx of 53.2% (p < 0.001) and 38.3% (p = 0.002), and in TAMn of 84.4% (p < 0.001) and 68.2% (p < 0.001). Semiquantitative power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.
Lateral supraorbital approach to ipsilateral PCA-P1 and ICA-PCoA aneurysms
Goehre, Felix; Jahromi, Behnam Rezai; Elsharkawy, Ahmed; Lehto, Hanna; Shekhtman, Oleg; Andrade-Barazarte, Hugo; Munoz, Francisco; Hijazy, Ferzat; Makhkamov, Makhkam; Hernesniemi, Juha
2015-01-01
Background: Aneurysms of the posterior cerebral artery (PCA) are rare and often associated with anterior circulation aneurysms. The lateral supraorbital approach allows for a very fast and safe approach to the ipsilateral lesions Circle of Willis. A technical note on the successful clip occlusion of two aneurysms in the anterior and posterior Circle of Willis via this less invasive approach has not been published before. The objective of this technical note is to describe the simultaneous microsurgical clip occlusion of an ipsilateral PCA-P1 and an internal carotid artery - posterior communicating artery (ICA-PCoA) aneurysm via the lateral supraorbital approach. Case Description: The authors present a technical report of successful clip occlusions of ipsilateral located PCA-P1 and ICA-PCoA aneurysms. A 59-year-old female patient was diagnosed with a PCA-P1 and an ipsilateral ICA-PCoA aneurysm by computed tomography angiography (CTA) after an ischemic stroke secondary to a contralateral ICA dissection. The patient underwent microsurgical clipping after a lateral supraorbital craniotomy. The intraoperative indocyanine green (ICG) videoangiography and the postoperative CTA showed a complete occlusion of both aneurysms; the parent vessels (ICA and PCA) were patent. The patient presents postoperative no new neurologic deficit. Conclusion: The lateral supraorbital approach is suitable for the simultaneous microsurgical treatment of proximal anterior circulation and ipsilateral proximal PCA aneurysms. Compared to endovascular treatment, direct visual control of brainstem perforators is possible. PMID:26060600
Lateral supraorbital approach to ipsilateral PCA-P1 and ICA-PCoA aneurysms.
Goehre, Felix; Jahromi, Behnam Rezai; Elsharkawy, Ahmed; Lehto, Hanna; Shekhtman, Oleg; Andrade-Barazarte, Hugo; Munoz, Francisco; Hijazy, Ferzat; Makhkamov, Makhkam; Hernesniemi, Juha
2015-01-01
Aneurysms of the posterior cerebral artery (PCA) are rare and often associated with anterior circulation aneurysms. The lateral supraorbital approach allows for a very fast and safe approach to the ipsilateral lesions Circle of Willis. A technical note on the successful clip occlusion of two aneurysms in the anterior and posterior Circle of Willis via this less invasive approach has not been published before. The objective of this technical note is to describe the simultaneous microsurgical clip occlusion of an ipsilateral PCA-P1 and an internal carotid artery - posterior communicating artery (ICA-PCoA) aneurysm via the lateral supraorbital approach. The authors present a technical report of successful clip occlusions of ipsilateral located PCA-P1 and ICA-PCoA aneurysms. A 59-year-old female patient was diagnosed with a PCA-P1 and an ipsilateral ICA-PCoA aneurysm by computed tomography angiography (CTA) after an ischemic stroke secondary to a contralateral ICA dissection. The patient underwent microsurgical clipping after a lateral supraorbital craniotomy. The intraoperative indocyanine green (ICG) videoangiography and the postoperative CTA showed a complete occlusion of both aneurysms; the parent vessels (ICA and PCA) were patent. The patient presents postoperative no new neurologic deficit. The lateral supraorbital approach is suitable for the simultaneous microsurgical treatment of proximal anterior circulation and ipsilateral proximal PCA aneurysms. Compared to endovascular treatment, direct visual control of brainstem perforators is possible.
Visual target modulation of functional connectivity networks revealed by self-organizing group ICA.
van de Ven, Vincent; Bledowski, Christoph; Prvulovic, David; Goebel, Rainer; Formisano, Elia; Di Salle, Francesco; Linden, David E J; Esposito, Fabrizio
2008-12-01
We applied a data-driven analysis based on self-organizing group independent component analysis (sogICA) to fMRI data from a three-stimulus visual oddball task. SogICA is particularly suited to the investigation of the underlying functional connectivity and does not rely on a predefined model of the experiment, which overcomes some of the limitations of hypothesis-driven analysis. Unlike most previous applications of ICA in functional imaging, our approach allows the analysis of the data at the group level, which is of particular interest in high order cognitive studies. SogICA is based on the hierarchical clustering of spatially similar independent components, derived from single subject decompositions. We identified four main clusters of components, centered on the posterior cingulate, bilateral insula, bilateral prefrontal cortex, and right posterior parietal and prefrontal cortex, consistently across all participants. Post hoc comparison of time courses revealed that insula, prefrontal cortex and right fronto-parietal components showed higher activity for targets than for distractors. Activation for distractors was higher in the posterior cingulate cortex, where deactivation was observed for targets. While our results conform to previous neuroimaging studies, they also complement conventional results by showing functional connectivity networks with unique contributions to the task that were consistent across subjects. SogICA can thus be used to probe functional networks of active cognitive tasks at the group-level and can provide additional insights to generate new hypotheses for further study. Copyright 2007 Wiley-Liss, Inc.
Marjanović, Ivan; Mijajlović, Milija; Covicković-Sternić, Nadezda; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija
2011-01-01
An altered perfusion of the optic nerve head has been proposed as a pathogenic factor in glaucoma. The aim of this study was to evaluate the correlation between ocular pulse amplitude (OPA), measured by Dynamic contour tonometer (DCT) and colour Doppler imaging (CDI) of the arteric retrobulbar vessels. Twenty patients older than 50 years were examined, and divided into two equal groups. The first group comprised of patients with normal tension glaucoma treated with topical antiglaucomatous therapy, and the second group included patients with ocular hypertension and glaucoma suspicious without any antiglaucomatous therapy. Ocular pulse amplitude (OPA) was measured with DCT. CDI was also performed. We measured haemodynamic parameters of the internal carotid artery (ICA), ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCA). Peak systolic (PSV), end-diastolic (EDV) velocities were measured, and resistance index (RI) and pulsatility index (PI) were calculated. Correlation with OPA showed indirect servitude in the RI of the ICA, RI and PI of the CRA, in the first group; and in the PSV and EDV of the ICA, in the RI and PI of the OA, EDV and RI of the CRA, and RI of the PCA, in the second group Increase of OPA was mostly followed by the increase of the parameters (PSV, EDV, RI, and PI) of the arteric retrobulbar vessels in the first group; in the second group, increase of OPA was in almost 50% of parameters followed by their decrease.
MacLea, H B; Boon, J A; Bright, J M
2013-01-01
Hypertrophic cardiomyopathy (HCM) is heterogeneous in both people and cats, with variability in the distribution of hypertrophy, hemodynamic characteristics, and Doppler echocardiographic findings. To document the Doppler echocardiographic characteristics of midventricular obstruction in some cats with HCM. Eight cats with hypertrophic cardiomyopathy. Retrospective case series. The medical records of cats presenting to the cardiology service at Colorado State University between February 2009 and January 2012 were reviewed. All cats had a physical examination; Doppler systolic blood pressure measurement; and transthoracic two-dimensional (2D), M-mode, and Doppler echocardiography were performed. A more thorough evaluation of the echocardiographic images and measurements was performed. Cats included in this study had echocardiograms of adequate quality to confirm the diagnosis of midventricular obstruction by documentation of left midventricular concentric hypertrophy; a midventricular turbulent Doppler color flow pattern; and high velocity, late-peaking flow at the area of turbulence. Cats with evidence of systemic hypertension defined as a systolic Doppler blood pressure of greater than 170 mmHg were excluded. All 8 cats had left ventricular hypertrophy at the level of the papillary muscles; left, midventricular hypertrophy; and in 4/8 cats there was apical hypertrophy or basilar hypertrophy of the interventricular septum. Color flow Doppler revealed turbulent flow in 8/8 cats and spectral Doppler (continuous and pulsed wave) revealed increased flow velocities and late-peaking flow profiles at the level of the left midventricle. Two of 8 cats had a bifid midventricular flow profile in which there was a midsystolic decline in left ventricular velocities with elevated velocities extending into early diastole. The peak left ventricular outflow velocity in all 8 cats was normal. A variant of HCM characterized by hypertrophy at the level of the papillary muscles with
Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D
2017-01-01
Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468
Live imaging of rat embryos with Doppler swept-source optical coherence tomography
NASA Astrophysics Data System (ADS)
Larina, Irina V.; Furushima, Kenryo; Dickinson, Mary E.; Behringer, Richard R.; Larin, Kirill V.
2009-09-01
The rat has long been considered an excellent system to study mammalian embryonic cardiovascular physiology, but has lacked the extensive genetic tools available in the mouse to be able to create single gene mutations. However, the recent establishment of rat embryonic stem cell lines facilitates the generation of new models in the rat embryo to link changes in physiology with altered gene function to define the underlying mechanisms behind congenital cardiovascular birth defects. Along with the ability to create new rat genotypes there is a strong need for tools to analyze phenotypes with high spatial and temporal resolution. Doppler OCT has been previously used for 3-D structural analysis and blood flow imaging in other model species. We use Doppler swept-source OCT for live imaging of early postimplantation rat embryos. Structural imaging is used for 3-D reconstruction of embryo morphology and dynamic imaging of the beating heart and vessels, while Doppler-mode imaging is used to visualize blood flow. We demonstrate that Doppler swept-source OCT can provide essential information about the dynamics of early rat embryos and serve as a basis for a wide range of studies on functional evaluation of rat embryo physiology.
Live imaging of rat embryos with Doppler swept-source optical coherence tomography
Larina, Irina V.; Furushima, Kenryo; Dickinson, Mary E.; Behringer, Richard R.; Larin, Kirill V.
2009-01-01
The rat has long been considered an excellent system to study mammalian embryonic cardiovascular physiology, but has lacked the extensive genetic tools available in the mouse to be able to create single gene mutations. However, the recent establishment of rat embryonic stem cell lines facilitates the generation of new models in the rat embryo to link changes in physiology with altered gene function to define the underlying mechanisms behind congenital cardiovascular birth defects. Along with the ability to create new rat genotypes there is a strong need for tools to analyze phenotypes with high spatial and temporal resolution. Doppler OCT has been previously used for 3-D structural analysis and blood flow imaging in other model species. We use Doppler swept-source OCT for live imaging of early postimplantation rat embryos. Structural imaging is used for 3-D reconstruction of embryo morphology and dynamic imaging of the beating heart and vessels, while Doppler-mode imaging is used to visualize blood flow. We demonstrate that Doppler swept-source OCT can provide essential information about the dynamics of early rat embryos and serve as a basis for a wide range of studies on functional evaluation of rat embryo physiology. PMID:19895102
Oxidative conditions prevail in severe IUGR with vascular disease and Doppler anomalies.
Maisonneuve, Emeline; Delvin, Edgard; Edgard, Annie; Morin, Lucie; Dubé, Johanne; Boucoiran, Isabelle; Moutquin, Jean-Marie; Fouron, Jean-Claude; Klam, Stephanie; Levy, Emile; Leduc, Line
2015-08-01
Intrauterine growth restriction (IUGR) and prenatal exposure to oxidative stress are thought to lead to increased risks of cardiovascular disease later in life. The objective of the present study was to document whether cord blood oxidative stress biomarkers vary with the severity of IUGR and of vascular disease in the twin pregnancy model in which both fetuses share the same maternal environment. This prospective cohort study involved dichorionic twin pairs, with one co-twin with IUGR. Oxidative stress biomarkers were measured in venous cord blood samples from each neonate of 32 twin pairs, and compared, according to severity of IUGR (IUGR <5th percentile), Doppler anomalies of the umbilical artery and early onset IUGR (in the second trimester) of the growth restricted twin. Oxidized Low-Density Lipoproteins (oxLDL) and Malondialdehyde (MDA) concentrations were increased proportionally in cases of severe IUGR. OxLDL concentrations were also increased in cases of IUGR with Doppler anomaly. Our data indicate that severe IUGR, is related to a derangement in redox balance, illustrated by increased venous cord blood oxidative stress biomarkers concentrations. Severe IUGR and IUGR with abnormal Doppler can be translated into conditions with intense oxidative stress.
Proceedings of the ICA Conference (4th, Washington, D.C., November 11-13, 1970).
ERIC Educational Resources Information Center
ICA Information, 1971
1971-01-01
The proceedings of the Fourth Conference of the Intergovernmental Council for ADP-ICA, are contained in this, the 7th issue of the ICA-Information, the Council's official publication. The proceedings include the edited minutes of the sessions, which covered the following topics: Management information systems for the government, Policy…
Single-channel mixed signal blind source separation algorithm based on multiple ICA processing
NASA Astrophysics Data System (ADS)
Cheng, Xiefeng; Li, Ji
2017-01-01
Take separating the fetal heart sound signal from the mixed signal that get from the electronic stethoscope as the research background, the paper puts forward a single-channel mixed signal blind source separation algorithm based on multiple ICA processing. Firstly, according to the empirical mode decomposition (EMD), the single-channel mixed signal get multiple orthogonal signal components which are processed by ICA. The multiple independent signal components are called independent sub component of the mixed signal. Then by combining with the multiple independent sub component into single-channel mixed signal, the single-channel signal is expanded to multipath signals, which turns the under-determined blind source separation problem into a well-posed blind source separation problem. Further, the estimate signal of source signal is get by doing the ICA processing. Finally, if the separation effect is not very ideal, combined with the last time's separation effect to the single-channel mixed signal, and keep doing the ICA processing for more times until the desired estimated signal of source signal is get. The simulation results show that the algorithm has good separation effect for the single-channel mixed physiological signals.
Quantification of absolute blood velocity using LDA
NASA Astrophysics Data System (ADS)
Borozdova, M. A.; Fedosov, I. V.; Tuchin, V. V.
2018-04-01
We developed novel schematics of a Laser Doppler anemometer where measuring volume is comparable with the red blood cell (RBC) size and a small period of interference fringes improves device resolution. The technique was used to estimate Doppler frequency shift at flow velocity measurements. It has been shown that technique is applicable for measurements in whole blood.
Superharmonic microbubble Doppler effect in ultrasound therapy
NASA Astrophysics Data System (ADS)
Pouliopoulos, Antonios N.; Choi, James J.
2016-08-01
The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 × 104-5 × 107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s-1, prior to the onset of
Superharmonic microbubble Doppler effect in ultrasound therapy
Pouliopoulos, Antonios N; Choi, James J
2016-01-01
Abstract The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5 × 104–5 × 107 microbubbles ml−1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75–366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s−1, prior to
FastICA peel-off for ECG interference removal from surface EMG.
Chen, Maoqi; Zhang, Xu; Chen, Xiang; Zhu, Mingxing; Li, Guanglin; Zhou, Ping
2016-06-13
Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.
Automated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA.
Sai, Chong Yeh; Mokhtar, Norrima; Arof, Hamzah; Cumming, Paul; Iwahashi, Masahiro
2018-05-01
Brain electrical activity recordings by electroencephalography (EEG) are often contaminated with signal artifacts. Procedures for automated removal of EEG artifacts are frequently sought for clinical diagnostics and brain-computer interface applications. In recent years, a combination of independent component analysis (ICA) and discrete wavelet transform has been introduced as standard technique for EEG artifact removal. However, in performing the wavelet-ICA procedure, visual inspection or arbitrary thresholding may be required for identifying artifactual components in the EEG signal. We now propose a novel approach for identifying artifactual components separated by wavelet-ICA using a pretrained support vector machine (SVM). Our method presents a robust and extendable system that enables fully automated identification and removal of artifacts from EEG signals, without applying any arbitrary thresholding. Using test data contaminated by eye blink artifacts, we show that our method performed better in identifying artifactual components than did existing thresholding methods. Furthermore, wavelet-ICA in conjunction with SVM successfully removed target artifacts, while largely retaining the EEG source signals of interest. We propose a set of features including kurtosis, variance, Shannon's entropy, and range of amplitude as training and test data of SVM to identify eye blink artifacts in EEG signals. This combinatorial method is also extendable to accommodate multiple types of artifacts present in multichannel EEG. We envision future research to explore other descriptive features corresponding to other types of artifactual components.
Automatic retinal blood flow calculation using spectral domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Wehbe, Hassan; Ruggeri, Marco; Jiao, Shuliang; Gregori, Giovanni; Puliafito, Carmen A.
2008-02-01
Optical Doppler tomography (ODT) is a branch of optical coherence tomography (OCT) that can measure the speed of a blood flow by measuring the Doppler shift impinged on the probing sample light by the moving blood cells. However, the measured speed of blood flow is a function of the Doppler angle, which needs to be determined in order to calculate the absolute velocity of the blood flow inside a vessel. We developed a technique that can extract the Doppler angle from the 3D data measured with spectral-domain OCT, which needs to extract the lateral and depth coordinates of a vessel in each measured ODT and OCT image. The lateral coordinates and the diameter of a blood vessel were first extracted in each OCT structural image by using the technique of blood vessel shadowgram, a technique first developed by us for enhancing the retinal blood vessel contrast in the en face view of the 3D OCT. The depth coordinate of a vessel was then determined by using a circular averaging filter moving in the depth direction along the axis passing through the vessel center in the ODT image. The Doppler angle was then calculated from the extracted coordinates of the blood vessel. The technique was applied in blood flow measurements in retinal blood vessels, which has potential impact on the study and diagnosis of blinding diseases like glaucoma and diabetic retinopathy.
Transcranial Doppler Ultrasound in Peninsular Arab Patients With Sickle Cell Disease.
Adekile, Adekunle; Hassan, Meaad; Asbeutah, Akram; Al-Hinai, Mohamed; Trad, Omar; Farhan, Nayef
2018-05-06
Transcranial Doppler ultrasound is used to identify patients with sickle cell disease (SCD) at risk for stroke. We performed transcranial Doppler studies in patients from 4 countries in the Arabian Peninsula (Kuwait, Oman, Iraq, and United Arab Emirates) to document the prevalence of abnormal transcranial Doppler findings. The patients were recruited from outpatient clinics and studied in a steady state. Transcranial Doppler examinations were performed with standard equipment by experienced operators. The time-averaged maximum mean velocity (TAMMV) was documented in the arteries of the circle of Willis. The hemoglobin (Hb) genotype was confirmed, and the fetal Hb level and complete blood counts were determined. There were 415 patients in the study, aged 2 to 18 years (mean ± SD, 8.6 ± 3.5 years). None of the patients had an abnormal TAMMV (ie, > 200 cm/s), whereas only 13 (3.1%), all from Iraq, had conditional values (170-200 cm/s) in the right middle cerebral artery and 7 (1.7%) in the left middle cerebral artery. There were no consistent TAMMV differences among male and female patients or in patients with different Hb genotypes (sickle cell anemia, sickle cell β 0- thalassemia, and sickle D). The use of hydroxyurea was associated with a lower TAMMV, whereas a blood transfusion history had no influence. Total hemoglobin, reticulocyte count, serum bilirubin, and fetal Hb values showed varying degrees of association with the TAMMV in the different vessels. This study has demonstrated the rarity of abnormal transcranial Doppler findings among Peninsular Arab patients with SCD. The guidelines for transcranial Doppler screening in this population need further studies and recommendations. © 2018 by the American Institute of Ultrasound in Medicine.
[Object Separation from Medical X-Ray Images Based on ICA].
Li, Yan; Yu, Chun-yu; Miao, Ya-jian; Fei, Bin; Zhuang, Feng-yun
2015-03-01
X-ray medical image can examine diseased tissue of patients and has important reference value for medical diagnosis. With the problems that traditional X-ray images have noise, poor level sense and blocked aliasing organs, this paper proposes a method for the introduction of multi-spectrum X-ray imaging and independent component analysis (ICA) algorithm to separate the target object. Firstly image de-noising preprocessing ensures the accuracy of target extraction based on independent component analysis and sparse code shrinkage. Then according to the main proportion of organ in the images, aliasing thickness matrix of each pixel was isolated. Finally independent component analysis obtains convergence matrix to reconstruct the target object with blind separation theory. In the ICA algorithm, it found that when the number is more than 40, the target objects separate successfully with the aid of subjective evaluation standard. And when the amplitudes of the scale are in the [25, 45] interval, the target images have high contrast and less distortion. The three-dimensional figure of Peak signal to noise ratio (PSNR) shows that the different convergence times and amplitudes have a greater influence on image quality. The contrast and edge information of experimental images achieve better effects with the convergence times 85 and amplitudes 35 in the ICA algorithm.
Zhang, Chi; Li, Shuyu; Pu, Fang; Fan, Yubo; Li, Deyu
2014-01-01
The anatomic variation of Circle of Willis (CoW) has great impact on its compensatory capacity during stroke and cerebral ischemia. In the present study, a series of lumped parameter models were developed and used to simulate the effect of postural changes on the cerebral blood flow in ICA stenosis patients with different anatomic variants of the CoW. The results showed that the asymmetric distribution of cerebral blood flow caused by stenosis was attenuated in standing position in complete and half-complete CoW. However, in incomplete CoW, the decrease in blood flow in the ipsilateral cerebral arteries caused by unilateral ICA stenosis was dramatic in both supine and standing positions, a likely result of inadequate collateral circulation within the CoW. In conclusion, the anatomic variation of CoW plays a significant role in maintaining the balance of cerebral blood supply in patients with ICA stenosis, especially during postural change.
Effect of non-linearity in predicting doppler waveforms through a novel model
Gayasen, Aman; Dua, Sunil Kumar; Sengupta, Amit; Nagchoudhuri, D
2003-01-01
Background In pregnancy, the uteroplacental vascular system develops de novo locally in utero and a systemic haemodynamic & bio-rheological alteration accompany it. Any abnormality in the non-linear vascular system is believed to trigger the onset of serious morbid conditions like pre-eclampsia and/or intrauterine growth restriction (IUGR). Exact Aetiopathogenesis is unknown. Advancement in the field of non-invasive doppler image analysis and simulation incorporating non-linearities may unfold the complexities associated with the inaccessible uteroplacental vessels. Earlier modeling approaches approximate it as a linear system. Method We proposed a novel electrical model for the uteroplacental system that uses MOSFETs as non-linear elements in place of traditional linear transmission line (TL) model. The model to simulate doppler FVW's was designed by including the inputs from our non-linear mathematical model. While using the MOSFETs as voltage-controlled switches, a fair degree of controlled-non-linearity has been introduced in the model. Comparative analysis was done between the simulated data and the actual doppler FVW's waveforms. Results & Discussion Normal pregnancy has been successfully modeled and the doppler output waveforms are simulated for different gestation time using the model. It is observed that the dicrotic notch disappears and the S/D ratio decreases as the pregnancy matures. Both these results are established clinical facts. Effects of blood density, viscosity and the arterial wall elasticity on the blood flow velocity profile were also studied. Spectral analysis on the output of the model (blood flow velocity) indicated that the Total Harmonic Distortion (THD) falls during the mid-gestation. Conclusion Total harmonic distortion (THD) is found to be informative in determining the Feto-maternal health. Effects of the blood density, the viscosity and the elasticity changes on the blood FVW are simulated. Future works are expected to concentrate
Honnens, A; Niemann, H; Paul, V; Meyer, H H D; Bollwein, H
2008-09-15
Transrectal color Doppler sonography was used to investigate the effects of a gonadotropin treatment to induce superovulation on uterine blood flow and its relationship with steroid hormone levels, ovarian response and embryo yield in dairy cows. The estrous cycle of 42 cows was synchronized by using PGF(2alpha) during diestrus and GnRH 48 h later (Day 0). Cows were examined on the day of eCG (2750 IU)-administration (Day 10), 3 days after eCG (Day 13) and 7 days after artificial insemination (Day 22), including the determination of total estrogens (E) and progesterone (P(4)) in peripheral plasma. Eight days after insemination (Day 23) the uterus was flushed and the number of total ova and embryos as well as transferable embryos was determined. The ovarian response was defined by the number of follicles>5.0mm in diameter on Day 13 and the number of corpora lutea on Day 22. Uterine blood flow was reflected by the blood flow volume (BFV) and the pulsatility index (PI) in the uterine arteries. Both variables showed distinct changes throughout the superovulatory cycle: BFV increased by 94% and PI decreased by 30% between Days 10 and 22 (P<0.0001). On Day 13, BFV but not PI correlated with follicle numbers (r=0.35; P<0.05); no correlation was found with E and P(4) (P>0.05). On Day 22, BFV correlated positively and PI correlated negatively with the number of corpora lutea (r=0.45 and r=-0.37; P<0.05) and P(4) (r=0.39 and r=-0.30; P<0.05). The number of transferable embryos was solely related to BFV measured on Day 13 (r=0.32; P<0.05). Our results show for the first time that in cows a superovulatory treatment is associated with a marked increase in BFV and a marked decrease in PI in the uterine arteries, concurrent with the development of multiple follicles and corpora lutea. However, transrectal color Doppler sonography of the uterine arteries does not facilitate the prediction of embryo yields following superovulatory treatment.
Eilbeigi, Elnaz; Setarehdan, Seyed Kamaledin
2018-05-26
Brain-computer interfaces (BCIs) are a promising tool in neurorehabilitation. The intention to perform a motor action can be detected from brain signals and used to control robotic devices. Most previous studies have focused on the starting of movements from a resting state, while in daily life activities, motions occur continuously and the neural activities correlated to the evolving movements are yet to be investigated. First we investigate the existence of neural correlates of intention to replace an object on the table during a holding phase. Next, we present a new method to extract the movement-related cortical potentials (MRCP) from a single-trial EEG. A novel method called Global optimal constrained ICA (GocICA) is proposed to overcome the limitations of cICA which is implemented based on Particle Swarm Optimization (PSO) and Charged System Search (CSS) techniques. GocICA is then utilized for decoding the intention to grasp and lift and intention to replace movements where the results were compared. It was found that GocICA significantly improves the intention detection performance. Best results in offline detection were obtained with CSS-cICA for both kinds of intentions. Furthermore, pseudo-online decoding showed that GocICA was able to predict both intentions before the onset of related movements with the highest probability. Decoding of the next movement intention during current movement is possible, which can be used to create more natural neuroprostheses. The results demonstrate that GocICA is a promising new algorithm for single-trial MRCP detection which can be used for detecting other types of ERPs such as P300. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hosseini, K.; Ayati, Z.; Ansari, R.
2018-04-01
One specific class of non-linear evolution equations, known as the Tzitzéica-type equations, has received great attention from a group of researchers involved in non-linear science. In this article, new exact solutions of the Tzitzéica-type equations arising in non-linear optics, including the Tzitzéica, Dodd-Bullough-Mikhailov and Tzitzéica-Dodd-Bullough equations, are obtained using the expa function method. The integration technique actually suggests a useful and reliable method to extract new exact solutions of a wide range of non-linear evolution equations.
Heat stress redistributes blood flow in arteries of the brain during dynamic exercise.
Sato, Kohei; Oue, Anna; Yoneya, Marina; Sadamoto, Tomoko; Ogoh, Shigehiko
2016-04-01
We hypothesized that heat stress would decrease anterior and posterior cerebral blood flow (CBF) during exercise, and the reduction in anterior CBF would be partly associated with large increase in extracranial blood flow (BF). Nine subjects performed 40 min of semirecumbent cycling at 60% of the peak oxygen uptake in hot (35°C; Heat) and thermoneutral environments (25°C; Control). We evaluated BF and conductance (COND) in the external carotid artery (ECA), internal carotid artery (ICA), and vertebral artery (VA) using ultrasonography. During the Heat condition, ICA and VA BF were significantly increased 10 min after the start of exercise (P < 0.05) and thereafter gradually decreased. ICA COND was significantly decreased (P < 0.05), whereas VA COND remained unchanged throughout Heat. Compared with the Control, either BF or COND of ICA and VA at the end of Heat tended to be lower, but not significantly. In contrast, ECA BF and COND at the end of Heat were both higher than levels in the Control condition (P < 0.01). During Heat, a reduction in ICA BF appears to be associated with a decline in end-tidal CO2 tension (r = 0.84), whereas VA BF appears to be affected by a change in cardiac output (r = 0.87). In addition, a change in ECA BF during Heat was negatively correlated with a change in ICA BF (r = -0.75). Heat stress resulted in modification of the vascular response of head and brain arteries to exercise, which resulted in an alteration in the distribution of cardiac output. Moreover, a hyperthermia-induced increase in extracranial BF might compromise anterior CBF during exercise with heat stress. Copyright © 2016 the American Physiological Society.
MicroV Technology to Improve Transcranial Color Coded Doppler Examinations.
Malferrari, Giovanni; Pulito, Giuseppe; Pizzini, Attilia Maria; Carraro, Nicola; Meneghetti, Giorgio; Sanzaro, Enzo; Prati, Patrizio; Siniscalchi, Antonio; Monaco, Daniela
2018-05-04
The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition. Copyright © 2018 by the American Society of Neuroimaging.
Kubo, Yoshitaka; Koji, Takahiro; Yoshida, Kenji; Saito, Hideo; Ogawa, Akira; Ogasawara, Kuniaki
2015-01-01
Aneurysms at non-branching sites in the supraclinoid internal carotid artery (ICA) can be classified as “blood blister-like aneurysms” (BBAs), which have blood blister-like configurations and fragile walls. While surgical treatment for the BBA in the acute stage is recommended, the optimal surgical procedure remains controversial. In the study reported here, we describe the case of a 37-year-old woman with a ruptured BBA in the ophthalmic segment of the right ICA who underwent wrap-clipping with external carotid artery–internal carotid artery bypass by intraoperative estimation of the measurement of cortical cerebral blood flow (CoBF) using a thermal diffusion flow probe. Trapping of the ICA in the acute stage of subarachnoid hemorrhage may result in ischemic complications secondary to hemodynamic hypoperfusion or occlusion of the perforating artery, and/or delayed vasospasm, even with concomitant bypass surgery. We believe that it is important to perform scheduled external carotid artery–internal carotid artery bypass before trapping of the ICA in patients with a ruptured BBA in the acute stage of subarachnoid hemorrhage and to perform wrap-clipping rather than trapping. This would provide much more CoBF if a reduction of CoBF occurs after trapping occlusion of the ICA including a ruptured BBA according to intraoperative CoBF monitoring. As far as we are aware, the case reported here is the first report on high-flow bypass and wrap-clipping for a ruptured BBA of the ICA using intraoperative monitoring of cerebral hemodynamics. PMID:26082641
Kijsamanmith, Kanittha; Vongsavan, Noppakun; Matthews, Bruce
2018-03-01
To determine the percentage of the blood flow signal that is derived from dental pulp when recording from exposed dentine in a human premolar. Recordings were made from 7 healthy teeth in 5 subjects (aged 22-33 yr.) with a laser Doppler flow meter (Periflux 4001) using either a red (635 nm) or an infrared (780 nm) laser. After exposing dentine above the buccal pulpal horn (cavity diam. 1.6 mm, depth 3 mm) and isolating the crown with opaque rubber dam, blood flow was recorded alternately with infrared or red light from the exposed dentine under four conditions: before and after injecting local anaesthetic (3% Mepivacaine without vasoconstrictor) (LA) over the apex of the root of the tooth; after exposing the pulp by cutting a buccal, class V cavity in the tooth; and after sectioning the coronal pulp transversely through the exposure. There was no significant change in mean blood flow recorded with either light source when the tooth was anaesthetized or when the pulp was exposed. After the pulp had been sectioned, the blood flow recorded with infrared light fell by 67.8% and with red light, by 68.4%. The difference between these effects was not significant. When recording blood flow from exposed coronal dentine with either infrared or red light in a tooth isolated with opaque rubber dam, about 68% to the signal was contributed by the pulp. The signal:noise ratio was better with infrared than red light, and when recording from dentine than enamel. Copyright © 2017 Elsevier Ltd. All rights reserved.
Investigation of Doppler spectra of laser radiation scattered inside hand skin during occlusion test
NASA Astrophysics Data System (ADS)
Kozlov, I. O.; Zherebtsov, E. A.; Zherebtsova, A. I.; Dremin, V. V.; Dunaev, A. V.
2017-11-01
Laser Doppler flowmetry (LDF) is a method widely used in diagnosis of microcirculation diseases. It is well known that information about frequency distribution of Doppler spectrum of the laser radiation scattered by moving red blood cells (RBC) usually disappears after signal processing procedure. Photocurrent’s spectrum distribution contains valuable diagnostic information about velocity distribution of the RBC. In this research it is proposed to compute the indexes of microcirculation in the sub-ranges of the Doppler spectrum as well as investigate the frequency distribution of the computed indexes.
SAMIR, Haney; SASAKI, Kazuaki; AHMED, Eman; KAREN, Aly; NAGAOKA, Kentaro; EL SAYED, Mohamed; TAYA, Kazuyoshi; WATANABE, Gen
2015-01-01
Although color Doppler ultrasonography has been used to evaluate testicular blood flow in many species, very little has been done in goat. Eight male Shiba goats were exposed to a single intramuscular injection of either gonadotropin-releasing hormone (GnRH group; 1 µg/kg BW) or human chorionic gonadotropin (hCG group; 25 IU/kg BW). Plasma testosterone (T), estradiol (E2) and inhibin (INH) were measured just before (0 hr) and at different intervals post injection by radioimmunoassay. Testis volume (TV) and Doppler indices, such as resistive index (RI) and pulsatility index (PI) of the supratesticular artery, were measured by B-mode and color Doppler ultrasonography, respectively. The results indicated an increase in testicular blood flow in both groups, as RI and PI decreased significantly (P<0.05), but this increase was significant higher and earlier in hCG group (1 hr) than in the GnRH group (2 hr). A high correlation was found for RI and PI with both T (RI, r= −0.862; PI, r= −0.707) and INH in the GnRH group (RI, r=0.661; PI, r=0.701). However, a significant (P<0.05) correlation was found between E2 and both RI (r= −0.610) and PI (r= −0.763) in hCG group. In addition, TV significantly increased and was highly correlated with RI in both groups (GnRH, r= −0.718; hCG, r= −0.779). In conclusion, hCG and GnRH may improve testicular blood flow and TV in Shiba goats. PMID:25715956
Functional subdivision of group-ICA results of fMRI data collected during cinema viewing.
Pamilo, Siina; Malinen, Sanna; Hlushchuk, Yevhen; Seppä, Mika; Tikka, Pia; Hari, Riitta
2012-01-01
Independent component analysis (ICA) can unravel functional brain networks from functional magnetic resonance imaging (fMRI) data. The number of the estimated components affects both the spatial pattern of the identified networks and their time-course estimates. Here group-ICA was applied at four dimensionalities (10, 20, 40, and 58 components) to fMRI data collected from 15 subjects who viewed a 15-min silent film ("At land" by Maya Deren). We focused on the dorsal attention network, the default-mode network, and the sensorimotor network. The lowest dimensionalities demonstrated most prominent activity within the dorsal attention network, combined with the visual areas, and in the default-mode network; the sensorimotor network only appeared with ICA comprising at least 20 components. The results suggest that even very low-dimensional ICA can unravel the most prominent functionally-connected brain networks. However, increasing the number of components gives a more detailed picture and functionally feasible subdivision of the major networks. These results improve our understanding of the hierarchical subdivision of brain networks during viewing of a movie that provides continuous stimulation embedded in an attention-directing narrative.
Functional Subdivision of Group-ICA Results of fMRI Data Collected during Cinema Viewing
Pamilo, Siina; Malinen, Sanna; Hlushchuk, Yevhen; Seppä, Mika; Tikka, Pia; Hari, Riitta
2012-01-01
Independent component analysis (ICA) can unravel functional brain networks from functional magnetic resonance imaging (fMRI) data. The number of the estimated components affects both the spatial pattern of the identified networks and their time-course estimates. Here group-ICA was applied at four dimensionalities (10, 20, 40, and 58 components) to fMRI data collected from 15 subjects who viewed a 15-min silent film (“At land” by Maya Deren). We focused on the dorsal attention network, the default-mode network, and the sensorimotor network. The lowest dimensionalities demonstrated most prominent activity within the dorsal attention network, combined with the visual areas, and in the default-mode network; the sensorimotor network only appeared with ICA comprising at least 20 components. The results suggest that even very low-dimensional ICA can unravel the most prominent functionally-connected brain networks. However, increasing the number of components gives a more detailed picture and functionally feasible subdivision of the major networks. These results improve our understanding of the hierarchical subdivision of brain networks during viewing of a movie that provides continuous stimulation embedded in an attention-directing narrative. PMID:22860044
NASA Astrophysics Data System (ADS)
de Jong, Daan L. K.; Meel-van den Abeelen, Aisha S. S.; Lagro, Joep; Claassen, Jurgen A. H. R.; Slump, Cornelis H.
2014-03-01
The measurement of the blood flow in the middle cerebral artery (MCA) using transcranial Doppler ultrasound (US) imaging is clinically relevant for the study of cerebral autoregulation. Especially in the aging population, impairement of the autoregulation may coincide or relate to loss of perfusion and consequently loss of brain function. The cerebral autoregulation can be assessed by relating the blood pressure to the blood flow in the brain. Doppler US is a widely used, non-invasive method to measure the blood flow in the MCA. However, Doppler flow imaging is known to produce results that are dependent of the operator. The angle of the probe insonation with respect to the centerline of the blood vessel is a well known factor for output variability. In patients also the skull must be traversed and the MCA must be detected, influencing the US signal intensity. In this contribution we report two studies. We describe first an in-vitro setup to study the Doppler flow in a situation where the ground truth is known. Secondly, we report on a study with healthy volunteers where the effects of small probe displacements on the flow velocity signals are investigated. For the latter purpose, a special probe holder was designed to control the experiment.
Grzesiak, Mariusz; Wilczynski, Jan
2013-01-01
The aims were to investigate whether there are any changes in placental and fetal circulation during Atosiban tocolysis within the first 48 hours of therapy. Detailed Doppler evaluation of placental and fetal circulation was performed prior to Atosiban administration and thereafter at 24 and 48 hours. Maternal heart rate and the pulsatility index (PI) in both uterine arteries (R-UtA, L-UtA) were assessed. Fetal heart rate (FHR), the resistance (RI) and pulsatility index (PI) of umbilical (UA) and middle cerebral artery (MCA) were measured. Additionally cerebroplacental ratio was calculated. E-wave/A-wave ratio (E/A) for atrioventricular valves, the myocardial performance index (MPI) and shortening fraction (SF) for both ventricles were calculated for both ventricles independently. To determine changes over time in all study variables analysis of variance (ANOVA) for repeated measurements followed by Tukey-Kramer's post hoc test was used. The effects of additional clinical covariates were checked. Maternal heart rate and blood flow in (R-UtA/L-UtA) were not altered significantly during Atosiban administration. No significant changes in FHR as well as Doppler parameters (RI, PI, PSV) in UA and MCA were recorded after 24/48 hours of tocolytic treatment. The mean values of cerebroplacental ratio (CPR) remained unaltered during treatment. Detailed evaluation of fetal cardiac function parameters (E/A, SF, MPI) calculated independently for both ventricles, revealed no significant changes over the time. To our best knowledge this study has been first evaluation of placental and fetal circulation with assessment of cardiac hemodynamic function during 48-hours administration of Atosiban. This kind of tocolysis treatment seems not to alter uterine nor fetal arterial blood flow pattern seriously. Hemodynamic cardiac activity in fetuses has remained unaffected. We cannot conclude definitely that there are absolutely no changes in the fetal hemodynamic condition due to Atosiban
Effects of implanted Doppler flowmeters on femoral vein autografts.
Michie, D D; Cowan, D F; Cain, C P; Bell, C C
1976-01-01
Thirteen femoral vein autografts were placed into the corresponding ipsilateral femoral arteries of 8 mongrel dogs. Cuff-type Doppler (ultrasonic) flowmeters were placed around six of the grafts. None of the vessels thrombosed. Blood flow velocities were measured in all vessels up until the time of sacrifice (mean 95 +/- 5 days after surgery) or accidental death (one dog, 49 days after surgery). The only case of graft failure was attributed to infection at the flowmeter site. With this single exception, the vein grafts exhibited uniformity in histological appearance from dog to dog. These data suggest that implantation of properly designed Doppler flow transducers may have clinical applications. This technique permits continuous or intermittent assessment of blood flow characteristics through a graft without additional trauma or cost to the patient. It is free of the many inherent disadvantages of chronically implanted electromagnetic flowmeters and may negate the need in some instances for followup angiographic studies. Images Fig. 1. Fig. 2. Fig. 3. PMID:130843
Monnet, Eric; Pelsue, Davyd; MacPhail, Catriona
2006-02-01
To validate laser doppler flowmetry (LDF) for measurement of blood flow in the stomach wall of dogs with gastric dilatation-volvulus (GDV). Six purpose-bred dogs and 24 dogs with naturally occurring GDV. Experimental and clinical. Capillary blood flow in the body of the stomach and pyloric antrum was measured with LDF (tissue perfusion unit (TPU) before and after induction of portal hypertension (PH) and after PH plus gastric ischemia (GI; PH + GI) and compared with flow measured by colored microsphere technique. Capillary flow was measured by LDF in the stomach wall of dogs with GDV. PH and PH+GI induced a significant reduction in blood flow in the body of the stomach (P = .019). A significant positive correlation was present between percent changes in capillary blood flow measured by LDF and colored microspheres after induction of PH + GI in the body of the stomach (r = 0.94, P = .014) and in the pyloric antrum (r = 0.95, P = .049). Capillary blood flow measured in the body of the stomach of 6 dogs that required partial gastrectomy (5.00+/-3.30 TPU) was significantly lower than in dogs that did not (28.00+/-14.40 TPU, P = .013). LDF can detect variations in blood flow in the stomach wall of dogs. LDF may have application for evaluation of stomach wall viability during surgery in dogs with GDV.
Hanzlicek, A S; Baumwart, R D; Payton, M E
2016-09-01
To determine if systolic blood pressure estimated by mitral regurgitation (MR) velocity can be used interchangeably with that estimated by high definition oscillometry (HDO) and Doppler ultrasonography (DU) in dogs with naturally occurring mitral valve disease (MVD). Forty-nine client-owned dogs with naturally occurring MVD. This is a retrospective study. Medical records were reviewed and dogs with MR caused by degenerative MVD were included if systolic blood pressure was estimated from MR velocity determined by continuous wave Doppler (CW), DU and HDO at the same visit. A Pearson product moment correlation coefficient was determined for each combination of measures and tested for significance with a paired t-test. Limits of agreement between 2 measures were determined by the 95% confidence interval of the average difference of the means and illustrated by Bland-Altman plots. Systolic pressure estimated from CW was significantly but only moderately correlated to DU (r = 0.42, p=0.0015) and HDO (r = 0.40, p=0.0021). Pressure estimated from DU was significantly but only moderately correlated to HDO (r = 0.57, p≤0.0001). Limits of agreement were wide for all measures including DU and CW (-61.9to 44.6 mmHg), HDO and CW (-65.2to 26.9 mmHg), and HDO and DU (-63.1 to 42.06 mmHg). Systolic blood pressure estimated by CW cannot be used interchangeably with HDO or DU in dogs with naturally occurring MVD. Copyright © 2016 Elsevier B.V. All rights reserved.
Trangmar, Steven J; Chiesa, Scott T; Stock, Christopher G; Kalsi, Kameljit K; Secher, Niels H; González-Alonso, José
2014-01-01
Intense exercise is associated with a reduction in cerebral blood flow (CBF), but regulation of CBF during strenuous exercise in the heat with dehydration is unclear. We assessed internal (ICA) and common carotid artery (CCA) haemodynamics (indicative of CBF and extra-cranial blood flow), middle cerebral artery velocity (MCA Vmean), arterial–venous differences and blood temperature in 10 trained males during incremental cycling to exhaustion in the heat (35°C) in control, dehydrated and rehydrated states. Dehydration reduced body mass (75.8 ± 3 vs. 78.2 ± 3 kg), increased internal temperature (38.3 ± 0.1 vs. 36.8 ± 0.1°C), impaired exercise capacity (269 ± 11 vs. 336 ± 14 W), and lowered ICA and MCA Vmean by 12–23% without compromising CCA blood flow. During euhydrated incremental exercise on a separate day, however, exercise capacity and ICA, MCA Vmean and CCA dynamics were preserved. The fast decline in cerebral perfusion with dehydration was accompanied by increased O2 extraction (P < 0.05), resulting in a maintained cerebral metabolic rate for oxygen (CMRO2). In all conditions, reductions in ICA and MCA Vmean were associated with declining cerebral vascular conductance, increasing jugular venous noradrenaline, and falling arterial carbon dioxide tension () (R2 ≥ 0.41, P ≤ 0.01) whereas CCA flow and conductance were related to elevated blood temperature. In conclusion, dehydration accelerated the decline in CBF by decreasing and enhancing vasoconstrictor activity. However, the circulatory strain on the human brain during maximal exercise does not compromise CMRO2 because of compensatory increases in O2 extraction. PMID:24835170
Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H
2008-01-01
A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P < .5). High valid pixel rate laser Doppler imager flow data can be obtained through transparent face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.
A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, Maoqi; Zhou, Ping
2015-01-01
This study presents a progressive FastICA peel-off (PFP) framework for high density surface electromyogram (EMG) decomposition. The novel framework is based on a shift-invariant model for describing surface EMG. The decomposition process can be viewed as progressively expanding the set of motor unit spike trains, which is primarily based on FastICA. To overcome the local convergence of FastICA, a “peel off” strategy (i.e. removal of the estimated motor unit action potential (MUAP) trains from the previous step) is used to mitigate the effects of the already identified motor units, so more motor units can be extracted. Moreover, a constrained FastICA is applied to assess the extracted spike trains and correct possible erroneous or missed spikes. These procedures work together to improve the decomposition performance. The proposed framework was validated using simulated surface EMG signals with different motor unit numbers (30, 70, 91) and signal to noise ratios (SNRs) (20, 10, 0 dB). The results demonstrated relatively large numbers of extracted motor units and high accuracies (high F1-scores). The framework was also tested with 111 trials of 64-channel electrode array experimental surface EMG signals during the first dorsal interosseous (FDI) muscle contraction at different intensities. On average 14.1 ± 5.0 motor units were identified from each trial of experimental surface EMG signals. PMID:25775496
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D
2012-10-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using the wavelet analysis of blood flow oscillations in rats. Twelve Sprague-Dawley rats were randomly assigned to three protocols, including pressure with local cooling (Δt = -10 °C), pressure with local heating (Δt = 10 °C) and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The 3 h loading period was divided into non-overlapping 30 min epochs for the analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased under the conditions of pressure with heating and of pressure without temperature changes, but maintained stable under the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers.
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D.
2012-01-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using wavelet analysis of blood flow oscillations in rats. Twelve Sprague Dawley rats were randomly assigned into three protocols, including pressure with local cooling (Δt= −10°C), pressure with local heating (Δt= 10°C), and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 hours. Skin blood flow was measured using laser Doppler flowmetry. The 3-hour loading period was divided into non-overlapping 30 min epochs for analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased in the conditions of pressure with heating and of pressure without temperature changes, but maintained stable in the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers. PMID:23010955
Oh, Hyung-Geun; Rhee, Eun-Jung
2016-11-01
Ischemic stroke is known to be an important vascular complication of diabetes. Intracranial arterial stenosis (ICAS) is considered as an important cause of stroke in Asians. We aimed to analyze the risk for ICAS assessed by transcranial Doppler (TCD) ultrasonography in different groups of young Korean subjects divided by glycated hemoglobin (HbA1c) levels. This study included 10,437 participants without history of cardiovascular diseases (81.3% men, mean age 43 years) from a health screening program, in whom TCD ultrasonography was used to detect greater than 50% ICAS based on criteria modified from the SONIA (Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis) trial. The subjects were divided into 3 groups according to HbA1c levels: HbA1c < 5.7%, 5.7 ≤ HbA1c < 6.5%, and HbA1c ≥ 6.5% or under medication for diabetes. Among the participants, 3.0% of the subjects had ICAS. The subjects with ICAS tended to have higher mean HbA1c level compared with those without ICAS (5.8 ± .8 versus 5.7 ± .6, P = .063). The proportion of subjects with ICAS significantly increased as the HbA1c increased from the first to the third group (2.8%, 3.0%, 4.6%, P for linear trend = .022). In logistic regression analysis with ICAS as the dependent variable, the group with HbA1c ≥ 6.5% showed significantly increased odds ratio for ICAS with subjects with HbA1c < 5.7% as the reference after adjustment for confounding variables (1.575, 95% confidence interval 1.056-2.347). However, this significance disappeared with inclusion of presence of hypertension in the model. The risk for ICAS assessed by TCD was increased in young Korean subjects with HbA1c ≥ 6.5%. However, this significance was attenuated after adjustment for presence of hypertension, suggesting the importance of hypertension in ICAS. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.
3D power Doppler ultrasound in early diagnosis of preeclampsia.
Neto, R Moreira; Ramos, J G L
2016-01-01
Preeclampsia is a known cause of maternal, fetal and neonatal morbidity and mortality. Thus, evaluation of the predicting value of comparing 3D power Doppler indices (3DPD) of uteroplacental circulation (UPC) in the first and second trimester in patients who developed preeclampsia (PE) and those who did not and testing the hypothesis that the parameters of vascularization and placenta flow intensity, as determined by three-dimensional ultrasound (3D), are different in normal pregnancies compared with preeclampsia, could be a suitable screening method. A prospective observational study using 3D power Doppler were performed to evaluate the placental perfusion in 96 pregnant women who came to do the ultrasound routine between 11 and 14 weeks. The placental vascular index (VI), flow index (FI), blood vessels and blood flow index (VFI) by three-dimensional Doppler histogram were calculated. All patients repeated the exam between 16 and 20 weeks. The outcome was scored as normal or preeclamptic. Placental vascular indices including VI, FI and VFI were significantly lower in preeclamptic placentas compared with controls in the study performed in the second trimester (p<0.001). There was not any statistical difference in the patients examined in the first trimester. Our findings suggest that 3D-power Doppler assessment of placental vascular indices in the second trimester has the potential to detect women at risk for subsequent development of PE. Copyright © 2015 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.
Mitigation of crosstalk based on CSO-ICA in free space orbital angular momentum multiplexing systems
NASA Astrophysics Data System (ADS)
Xing, Dengke; Liu, Jianfei; Zeng, Xiangye; Lu, Jia; Yi, Ziyao
2018-09-01
Orbital angular momentum (OAM) multiplexing has caused a lot of concerns and researches in recent years because of its great spectral efficiency and many OAM systems in free space channel have been demonstrated. However, due to the existence of atmospheric turbulence, the power of OAM beams will diffuse to beams with neighboring topological charges and inter-mode crosstalk will emerge in these systems, resulting in the system nonavailability in severe cases. In this paper, we introduced independent component analysis (ICA), which is known as a popular method of signal separation, to mitigate inter-mode crosstalk effects; furthermore, aiming at the shortcomings of traditional ICA algorithm's fixed iteration speed, we proposed a joint algorithm, CSO-ICA, to improve the process of solving the separation matrix by taking advantage of fast convergence rate and high convergence precision of chicken swarm algorithm (CSO). We can get the optimal separation matrix by adjusting the step size according to the last iteration in CSO-ICA. Simulation results indicate that the proposed algorithm has a good performance in inter-mode crosstalk mitigation and the optical signal-to-noise ratio (OSNR) requirement of received signals (OAM+2, OAM+4, OAM+6, OAM+8) is reduced about 3.2 dB at bit error ratio (BER) of 3.8 × 10-3. Meanwhile, the convergence speed is much faster than the traditional ICA algorithm by improving about an order of iteration times.
Miura, Masahiro; Hong, Young-Joo; Yasuno, Yoshiaki; Muramatsu, Daisuke; Iwasaki, Takuya; Goto, Hiroshi
2015-03-01
To evaluate the 3-dimensional architecture of neovascularization in proliferative diabetic retinopathy using Doppler optical coherence tomography (OCT). Prospective, nonrandomized clinical trial. Seventeen eyes of 14 patients with proliferative diabetic retinopathy were prospectively studied. Prototype Doppler OCT was used to evaluate the 3-dimensional vascular architecture at vitreoretinal adhesions. Proliferative membranes were detected in all eyes with proliferative diabetic retinopathy by standard OCT images. Doppler OCT images detected blood flow by neovascularization of the disc in 12 eyes and neovascularization elsewhere in 11 eyes. Doppler OCT images showed the 3-dimensional extent of new vessels at various stages of neovascularization, and the extent of new vessels could be clearly confirmed at vitreoretinal adhesions. Doppler OCT is useful for the detection and evaluation of the 3-dimensional vascular structure of neovascularization, and can assist in the noninvasive assessment of proliferative diabetic retinopathy. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Efficiency of use endobronchial laser doppler-flowmetry in patients with chronic leukemia
NASA Astrophysics Data System (ADS)
Vanina, E. A.; Voitsekhovskiy, V. V.; Landyshev, Y. S.; Tkacheva, S. I.
2016-11-01
In this work indicatorsendobronchial microcirculation were investigated in patients with chronic myeloid leukemia (CML), chronic lymphocytic leukemia (CLL), multiple myeloma (MM), polycythemia vera (PV), idiopathic myelofibrosis (IMF). A diagnostic bronchoscopy was performed using fibreoptic «Olympus» (Japan).Endobronchial laser Doppler flowmetry was carried out on the laser analyzer capillary blood LAK-02 (Russia). Laser Doppler flowmetry indicators such as parameter of microcirculation, the oscillation amplitude in the endothelial, neurogenic, myogenic, cardiac and respiratory ranges were calculated by continuous the Wavelet transforms. Reduced cardiac and respiratory amplitudes in CML and CLL are primarily due to the development leukostasis. If PV is the case, this is due to sludge syndrome. And when MM occurs, it is caused by protein stasis in the vessels of the bronchial tubes. Increased endothelial oscillation amplitudes in the range in CML, PV, IMF and their reduction in MM indicate the presence of endothelial dysfunction in these patients. Increasing the amplitude of oscillations in the range of neurogenic indicates the development of arteriolar vasodilation as a compensatory response to the violation of blood flow. Increasing the amplitude of oscillations of myogenic tone indicating decrease precapillaries as a compensatory reaction to improve blood flow. It is concluded that endobronchial laser Doppler flowmetry is an important method allowing diagnosing the pathology of the microvasculature of the bronchi in chronic leukemia.
Saleh, M; Karfoul, A; Kachenoura, A; Senhadji, L; Albera, L
2016-08-01
Improving the execution time and the numerical complexity of the well-known kurtosis-based maximization method, the RobustICA, is investigated in this paper. A Newton-based scheme is proposed and compared to the conventional RobustICA method. A new implementation using the nonlinear Conjugate Gradient one is investigated also. Regarding the Newton approach, an exact computation of the Hessian of the considered cost function is provided. The proposed approaches and the considered implementations inherit the global plane search of the initial RobustICA method for which a better convergence speed for a given direction is still guaranteed. Numerical results on Magnetic Resonance Spectroscopy (MRS) source separation show the efficiency of the proposed approaches notably the quasi-Newton one using the BFGS method.
[The application of Doppler broadening and Doppler shift to spectral analysis].
Xu, Wei; Fang, Zi-shen
2002-08-01
The distinction between Doppler broadening and Doppler shift has analyzed, Doppler broadening locally results from the distribution of velocities of the emitting particles, the line width gives the information on temperature of emitting particles. Doppler shift results when the emitting particles have a bulk non random flow velocity in a particular direction, the drift of central wavelength gives the information on flow velocity of emitting particles, and the Doppler shift only drifts the profile of line without changing the width. The difference between Gaussian fitting and the distribution of chord-integral line shape have also been discussed. The distribution of H alpha spectral line shape has been derived from the surface of limiter in HT-6M Tokamak with optical spectroscope multichannel analysis (OSMA), the result by double Gaussian fitting shows that the line shape make up of two port, the emitting of reflect particles with higher energy and the release particle from the limiter surface. Ion temperature and recycling particle flow velocity have been obtained from Doppler broadening and Doppler shift.
NASA Technical Reports Server (NTRS)
Arbeille, P.; Berson, M.; Blondeau, B.; Durand, A.; Bodard, S.; Locatelli, A.; Fox, G. E. (Principal Investigator)
1995-01-01
The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).
Pierie, J P; De Graaf, P W; Poen, H; Van der Tweel, I; Obertop, H
1994-11-01
To assess the value of relative blood perfusion of the gastric tube in prediction of impaired healing of cervical oesophagogastrostomies. Prospective study. University hospital, The Netherlands. Thirty patients undergoing transhiatal oesophagectomy and partial gastrectomy for cancer of the oesophagus or oesophagogastric junction, with gastric tube reconstruction and cervical oesophagogastrostomy. Operative measurement of gastric blood perfusion at four sites by laser Doppler flowmetry and perfusion of the same sites after construction of the gastric tube expressed as a percentage of preconstruction values. The relative perfusion at the most proximal site of the gastric tube was significantly lower than at the more distal sites (p = 0.001). Nine of 18 patients (50%) in whom the perfusion of the proximal gastric tube was less than 70% of preconstruction values developed an anastomotic stricture, compared with only 1 of 12 patients (8%) with a relative perfusion of 70% or more (p = 0.024). A reduction in perfusion of the gastric tube did not predict leakage. Impaired anastomotic healing is unlikely if relative perfusion is 70% or more of preconstruction values. Perfusion of less than 70% partly predicts the occurrence of anastomotic stricture, but leakage cannot be predicted. Factors other than blood perfusion may have a role in the process of anastomotic healing.
Normal Doppler velocimetry of renal vasculature in Persian cats.
Carvalho, Cibele F; Chammas, Maria C
2011-06-01
Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m
Accuracy of three-dimensional multislice view Doppler in diagnosis of morbid adherent placenta
Abdel Moniem, Alaa M.; Ibrahim, Ahmed; Akl, Sherif A.; Aboul-Enen, Loay; Abdelazim, Ibrahim A.
2015-01-01
Objective To detect the accuracy of the three-dimensional multislice view (3D MSV) Doppler in the diagnosis of morbid adherent placenta (MAP). Material and Methods Fifty pregnant women at ≥28 weeks gestation with suspected MAP were included in this prospective study. Two dimensional (2D) trans-abdominal gray-scale ultrasound scan was performed for the subjects to confirm the gestational age, placental location, and findings suggestive of MAP, followed by the 3D power Doppler and then the 3D MSV Doppler to confirm the diagnosis of MAP. Intraoperative findings and histopathology results of removed uteri in cases managed by emergency hysterectomy were compared with preoperative sonographic findings to detect the accuracy of the 3D MSV Doppler in the diagnosis of MAP. Results The 3D MSV Doppler increased the accuracy and predictive values of the diagnostic criteria of MAP compared with the 3D power Doppler. The sensitivity and negative predictive value (NPV) (79.6% and 82.2%, respectively) of crowded vessels over the peripheral sub-placental zone to detect difficult placental separation and considerable intraoperative blood loss in cases of MAP using the 3D power Doppler was increased to 82.6% and 84%, respectively, using the 3D MSV Doppler. In addition, the sensitivity, specificity, and positive predictive value (PPV) (90.9%, 68.8%, and 47%, respectively) of the disruption of the uterine serosa-bladder interface for the detection of emergency hysterectomy in cases of MAP using the 3D power Doppler was increased to 100%, 71.8%, and 50%, respectively, using the 3D MSV Doppler. Conclusion The 3D MSV Doppler is a useful adjunctive tool to the 3D power Doppler or color Doppler to refine the diagnosis of MAP. PMID:26401104
NASA Astrophysics Data System (ADS)
Mishra, Puneet; Singla, Sunil Kumar
2013-01-01
In the modern world of automation, biological signals, especially Electroencephalogram (EEG) and Electrocardiogram (ECG), are gaining wide attention as a source of biometric information. Earlier studies have shown that EEG and ECG show versatility with individuals and every individual has distinct EEG and ECG spectrum. EEG (which can be recorded from the scalp due to the effect of millions of neurons) may contain noise signals such as eye blink, eye movement, muscular movement, line noise, etc. Similarly, ECG may contain artifact like line noise, tremor artifacts, baseline wandering, etc. These noise signals are required to be separated from the EEG and ECG signals to obtain the accurate results. This paper proposes a technique for the removal of eye blink artifact from EEG and ECG signal using fixed point or FastICA algorithm of Independent Component Analysis (ICA). For validation, FastICA algorithm has been applied to synthetic signal prepared by adding random noise to the Electrocardiogram (ECG) signal. FastICA algorithm separates the signal into two independent components, i.e. ECG pure and artifact signal. Similarly, the same algorithm has been applied to remove the artifacts (Electrooculogram or eye blink) from the EEG signal.
Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI
Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A.
2018-01-01
Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10–30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected. PMID:29410611
Diagnosis of brain death by transcranial Doppler sonography.
Bode, H; Sauer, M; Pringsheim, W
1988-12-01
The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As soon as there was a clinical deterioration, there was a reduction in flow velocities with retrograde flow during early diastole, probably due to an increase in cerebrovascular resistance; this indicated a doubtful prognosis. In eight of the nine children with clinical signs of brain death a typical reverberating flow pattern was found, which was characterised by a counterbalancing short forward flow in systole and a short retrograde flow in early diastole. This indicated arrest of cerebral blood flow. One newborn showed normal systolic and end diastolic flow velocities in the basal cerebral arteries for two days despite clinical and electroencephalographic signs of brain death. Shunting of blood through the circle of Willis without effective cerebral perfusion may explain this phenomenon. No patient had the typical reverberating flow pattern without being clinically brain dead. Transcranial Doppler sonography is a reliable technique, which can be used at the bedside for the confirmation or the exclusion of brain death in children in addition to the clinical examination.
Diagnosis of brain death by transcranial Doppler sonography.
Bode, H; Sauer, M; Pringsheim, W
1988-01-01
The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As soon as there was a clinical deterioration, there was a reduction in flow velocities with retrograde flow during early diastole, probably due to an increase in cerebrovascular resistance; this indicated a doubtful prognosis. In eight of the nine children with clinical signs of brain death a typical reverberating flow pattern was found, which was characterised by a counterbalancing short forward flow in systole and a short retrograde flow in early diastole. This indicated arrest of cerebral blood flow. One newborn showed normal systolic and end diastolic flow velocities in the basal cerebral arteries for two days despite clinical and electroencephalographic signs of brain death. Shunting of blood through the circle of Willis without effective cerebral perfusion may explain this phenomenon. No patient had the typical reverberating flow pattern without being clinically brain dead. Transcranial Doppler sonography is a reliable technique, which can be used at the bedside for the confirmation or the exclusion of brain death in children in addition to the clinical examination. PMID:3069052
Trangmar, Steven J; Chiesa, Scott T; Stock, Christopher G; Kalsi, Kameljit K; Secher, Niels H; González-Alonso, José
2014-07-15
Intense exercise is associated with a reduction in cerebral blood flow (CBF), but regulation of CBF during strenuous exercise in the heat with dehydration is unclear. We assessed internal (ICA) and common carotid artery (CCA) haemodynamics (indicative of CBF and extra-cranial blood flow), middle cerebral artery velocity (MCA Vmean), arterial-venous differences and blood temperature in 10 trained males during incremental cycling to exhaustion in the heat (35°C) in control, dehydrated and rehydrated states. Dehydration reduced body mass (75.8 ± 3 vs. 78.2 ± 3 kg), increased internal temperature (38.3 ± 0.1 vs. 36.8 ± 0.1°C), impaired exercise capacity (269 ± 11 vs. 336 ± 14 W), and lowered ICA and MCA Vmean by 12-23% without compromising CCA blood flow. During euhydrated incremental exercise on a separate day, however, exercise capacity and ICA, MCA Vmean and CCA dynamics were preserved. The fast decline in cerebral perfusion with dehydration was accompanied by increased O2 extraction (P < 0.05), resulting in a maintained cerebral metabolic rate for oxygen (CMRO2). In all conditions, reductions in ICA and MCA Vmean were associated with declining cerebral vascular conductance, increasing jugular venous noradrenaline, and falling arterial carbon dioxide tension (P aCO 2) (R(2) ≥ 0.41, P ≤ 0.01) whereas CCA flow and conductance were related to elevated blood temperature. In conclusion, dehydration accelerated the decline in CBF by decreasing P aCO 2 and enhancing vasoconstrictor activity. However, the circulatory strain on the human brain during maximal exercise does not compromise CMRO2 because of compensatory increases in O2 extraction. © 2014 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
Bryant, Simon; Kimura, Tomomi E; Kong, Cherrie H T; Watson, Judy J; Chase, Anabelle; Suleiman, M Saadeh; James, Andrew F; Orchard, Clive H
2014-03-01
L-type Ca channels (LTCC), which play a key role in cardiac excitation-contraction coupling, are located predominantly at the transverse (t-) tubules in ventricular myocytes. Caveolae and the protein caveolin-3 (Cav-3) are also present at the t-tubules and have been implicated in localizing a number of signaling molecules, including protein kinase A (PKA) and β2-adrenoceptors. The present study investigated whether disruption of Cav-3 binding to its endogenous binding partners influenced LTCC activity. Ventricular myocytes were isolated from male Wistar rats and LTCC current (ICa) recorded using the whole-cell patch-clamp technique. Incubation of myocytes with a membrane-permeable peptide representing the scaffolding domain of Cav-3 (C3SD) reduced basal ICa amplitude in intact, but not detubulated, myocytes, and attenuated the stimulatory effects of the β2-adrenergic agonist zinterol on ICa. The PKA inhibitor H-89 also reduced basal ICa; however, the inhibitory effects of C3SD and H-89 on basal ICa amplitude were not summative. Under control conditions, myocytes stained with antibody against phosphorylated LTCC (pLTCC) displayed a striated pattern, presumably reflecting localization at the t-tubules. Both C3SD and H-89 reduced pLTCC staining at the z-lines but did not affect staining of total LTCC or Cav-3. These data are consistent with the idea that the effects of C3SD and H-89 share a common pathway, which involves PKA and is maximally inhibited by H-89, and suggest that Cav-3 plays an important role in mediating stimulation of ICa at the t-tubules via PKA-induced phosphorylation under basal conditions, and in response to β2-adrenoceptor stimulation. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Xue, Kang; Liu, Ailin; Hui, Ren; Zhang, Jing; Qian, Jiang
2017-10-01
To evaluate the effects of intra-arterial chemotherapy on retrobulbar blood flow parameters in patients with retinoblastoma. 20 eyes of 10 patients with unilateral retinoblastoma that were treated with intra-arterial chemotherapy were evaluated using colour Doppler imaging. The peak systolic and end-diastolic velocities of the ophthalmic, central retinal and posterior ciliary arteries were determined. The pulsatility and resistance indices were calculated automatically. The treated eye was compared with the untreated (control) eye and with itself before and after intra-arterial chemotherapy. When comparing the retinoblastoma-containing eyes with the contralateral normal eyes, the peak systolic and end-diastolic velocities of the central retinal artery were significantly higher in the tumorous eyes than in the normal eyes before intra-arterial chemotherapy. Moreover, the peak systolic and end-diastolic velocities in the posterior ciliary and central retinal arteries were significantly decreased after intra-arterial chemotherapy in the tumorous eyes (p<0.05). There were no statistically significant differences in the other parameters. Our results suggest that intra-arterial chemotherapy has a measurable effect on the retrobulbar blood flow, which can cause a decrease in the peak systolic and end-diastolic velocities in the posterior ciliary and central retinal arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Chen, Defu; Ren, Jie; Wang, Ying; Li, Buhong; Gu, Ying
2016-06-01
The objective of this study was to monitor blood perfusion dynamics of port wine stains (PWS) during vascular targeted photodynamic therapy (V-PDT) with laser Doppler imaging (LDI). The PWS lesions of 30 facial PWS patients received V-PDT, while the normal skins on the forearm of 5 healthy subjects were treated as light-only controls for comparison. Furthermore, two different PWS lesions in the same individual from each of 3 PWS patients successively received laser irradiation only and V-PDT, respectively. LDI was used to monitor intraoperative blood perfusion dynamics. During V-PDT, the blood perfusion (278±96 PU) in PWS lesions for 31 of 33 PWS patients significantly increased after the initiation of V-PDT treatment, then reached a peak (638±105 PU) within 10min, followed by a slow decrease to a relatively lower level (515±100 PU). Furthermore, the time for reaching peak and the subsequent magnitude of decrease in blood perfusion varied with different patients. For light-only controls, an initial perfusion peak at 3min followed by a nadir and a secondary increase were found not only in normal skin, but also in PWS lesions. The preliminary results showed that the LDI permits non-invasive monitoring blood perfusion changes of PWS lesions during V-PDT. There was a clear trend in blood perfusion responses during V-PDT and laser irradiation. The blood perfusion changes during treatment were due to V-PDT effects as well as local temperature increase induced by laser irradiation. Copyright © 2016 Elsevier B.V. All rights reserved.
Dove prism based rotating dual beam bidirectional Doppler OCT
Blatter, Cedric; Coquoz, Séverine; Grajciar, Branislav; Singh, Amardeep S. G.; Bonesi, Marco; Werkmeister, René M.; Schmetterer, Leopold; Leitgeb, Rainer A.
2013-01-01
Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series. PMID:23847742
tICA-Metadynamics: Accelerating Metadynamics by Using Kinetically Selected Collective Variables.
M Sultan, Mohammad; Pande, Vijay S
2017-06-13
Metadynamics is a powerful enhanced molecular dynamics sampling method that accelerates simulations by adding history-dependent multidimensional Gaussians along selective collective variables (CVs). In practice, choosing a small number of slow CVs remains challenging due to the inherent high dimensionality of biophysical systems. Here we show that time-structure based independent component analysis (tICA), a recent advance in Markov state model literature, can be used to identify a set of variationally optimal slow coordinates for use as CVs for Metadynamics. We show that linear and nonlinear tICA-Metadynamics can complement existing MD studies by explicitly sampling the system's slowest modes and can even drive transitions along the slowest modes even when no such transitions are observed in unbiased simulations.
High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.
Xu, Xiaochen; Sun, Lei; Cannata, Jonathan M; Yen, Jesse T; Shung, K Kirk
2008-04-01
In this paper, we report the development of the first high-frequency (HF) pulsed-wave Doppler system using a 30-MHz linear array transducer to assess the cardiovascular functions in small animals. This array-based pulsed-wave Doppler system included a 16-channel HF analog beamformer, a HF pulsed-wave Doppler module, timing circuits, HF bipolar pulsers and analog front ends. The beamformed echoes acquired by the 16-channel analog beamformer were fed directly to the HF pulsed-wave Doppler module. Then the in-phase and quadrature-phase (IQ) audio Doppler signals were digitized by either a sound card or a Gage digitizer and stored in a personal computer. The Doppler spectrogram was displayed on a personal computer in real time. The two-way beamwidths were determined to be 160 microm to 320 microm when the array was electronically focused at different focal points at depths from 5 to 10 mm. A micro-flow phantom, consisting of a polyimide tube with an inner diameter of 127 microm and the wire phantom were used to evaluate and calibrate the system. The results show that the system is capable of detecting motion velocity of the wire phantom as low as 0.1 mm/s, and detecting blood-mimicking flow velocity in the 127-microm tube lower than 7 mm/s. The system was subsequently used to measure the blood flow in vivo in two mouse abdominal superficial vessels, with diameters of approximately 200 microm, and a mouse aorta close to the heart. These results demonstrated that this system may become an indispensable part of the current HF array-based imaging systems for small animal studies.
Löffler, Christian; Sattler, Horst; Peters, Lena; Tuleweit, Anika; Löffler, Uta; Wadsack, Daniel; Uppenkamp, Michael; Bergner, Raoul
2016-10-01
Power Doppler ultrasound is used to assess joint vascularity in acute arthritis. PDUS signals have been correlated with synovial histology and bone deterioration. Little is known about the correlation between power Doppler signals and synovial white blood count. In our study, we analyzed power Doppler signals in inflammatory joint diseases including gout, calcium pyrophosphate deposition disease, rheumatoid arthritis, spondyloarthritis and others and correlated power Doppler signals with synovial white blood count and with serologic markers of inflammation. We retrospectively evaluated 194 patients with arthritis. All patients underwent joint sonography, power Doppler ultrasound, synovial fluid analysis and blood examination of C-reactive protein and erythrocyte sedimentation rate. Correlation analyses (Spearman and Pearson), Chi(2) test, t-tests, a unifactorial ANOVA and regression analyses were applied. Hypervascularisation in power Doppler was most prominent in gout and calcium pyrophosphate deposition disease. Spondyloarthritis and non-inflammatory joint diseases presented with low degrees of hypervascularisation. Mean synovial white blood count did not differ significantly between crystal-related arthritides, rheumatoid arthritis, spondyloarthritis or other inflammatory joint diseases. There was a positive but weak correlation between power Doppler signals and synovial white blood count (P<0.001, rs=0.283), erythrocyte sedimentation rate (P<0.001, rs=0.387) and C-reactive protein (P<0.001, rs=0.373) over all diagnoses. This was especially relevant in rheumatoid arthritis (P<0.01, rs=0.479). Power Doppler degrees 0 and 1 were able to predict synovial leukocytes<5/nL, degrees 2 and 3 predict leukocytes≥5/nL (P<0.001). Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.
Mabrouk, Rostom; Dubeau, François; Bentabet, Layachi
2013-01-01
Kinetic modeling of metabolic and physiologic cardiac processes in small animals requires an input function (IF) and a tissue time-activity curves (TACs). In this paper, we present a mathematical method based on independent component analysis (ICA) to extract the IF and the myocardium's TACs directly from dynamic positron emission tomography (PET) images. The method assumes a super-Gaussian distribution model for the blood activity, and a sub-Gaussian distribution model for the tissue activity. Our appreach was applied on 22 PET measurement sets of small animals, which were obtained from the three most frequently used cardiac radiotracers, namely: desoxy-fluoro-glucose ((18)F-FDG), [(13)N]-ammonia, and [(11)C]-acetate. Our study was extended to PET human measurements obtained with the Rubidium-82 ((82) Rb) radiotracer. The resolved mathematical IF values compare favorably to those derived from curves extracted from regions of interest (ROI), suggesting that the procedure presents a reliable alternative to serial blood sampling for small-animal cardiac PET studies.
Relationship of oscillating and average components of laser Doppler flowmetry signal
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Frick, Peter; Podtaev, Sergey
2016-08-01
Signals from laser Doppler flowmeters widely used in intravital studies of skin blood flow include, along with a slowly varying average component, an oscillating part. However, in most clinical studies, pulsations are usually smoothed by data preprocessing and only the mean blood flow is analyzed. To reveal the relationship between average and oscillating perfusion components measured by a laser Doppler flowmeter, we examined the microvascular response to the contralateral cold pressor test recorded at two different sites of the hand: dorsal part of the arm and finger pad. Such a protocol makes it possible to provide a wide range of perfusion. The average perfusion always decreases during cooling, while the oscillating component demonstrates a differently directed response. The wavelet analysis of laser Doppler flowmetry (LDF) signals shows that the pulsatile component is nonlinearly related to the average perfusion. Under low perfusion, the amplitude of pulsations is proportional to its mean value, but, as perfusion increases, the amplitude of pulsations becomes lower. The type of response is defined by the basal perfusion and the degree of vasoconstriction caused by cooling. Interpretation of the results is complicated by the nonlinear transfer function of the LDF device, the contribution of which is studied using artificial examples.
NASA Astrophysics Data System (ADS)
Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.
2016-04-01
Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.
Karimi, Fatemeh; Kofman, Jonathan; Mrachacz-Kersting, Natalie; Farina, Dario; Jiang, Ning
2017-01-01
The movement related cortical potential (MRCP), a slow cortical potential from the scalp electroencephalogram (EEG), has been used in real-time brain-computer-interface (BCI) systems designed for neurorehabilitation. Detecting MPCPs in real time with high accuracy and low latency is essential in these applications. In this study, we propose a new MRCP detection method based on constrained independent component analysis (cICA). The method was tested for MRCP detection during executed and imagined ankle dorsiflexion of 24 healthy participants, and compared with four commonly used spatial filters for MRCP detection in an offline experiment. The effect of cICA and the compared spatial filters on the morphology of the extracted MRCP was evaluated by two indices quantifying the signal-to-noise ratio and variability of the extracted MRCP. The performance of the filters for detection was then directly compared for accuracy and latency. The latency obtained with cICA (-34 ± 29 ms motor execution (ME) and 28 ± 16 ms for motor imagery (MI) dataset) was significantly smaller than with all other spatial filters. Moreover, cICA resulted in greater true positive rates (87.11 ± 11.73 for ME and 86.66 ± 6.96 for MI dataset) and lower false positive rates (20.69 ± 13.68 for ME and 19.31 ± 12.60 for MI dataset) compared to the other methods. These results confirm the superiority of cICA in MRCP detection with respect to previously proposed EEG filtering approaches.
Bayoglu Tekin, Yesim; Guvendag Guven, Emine Seda; Mete Ural, Ulku; Yazici, Zihni Acar; Kirbas, Aynur; Kir Sahin, Figen
2016-01-01
The aim of this study was to evaluate maternal neutrophil gelatinase-asssociated lipocalin (NGAL) levels and fetal renal artery (fRA) Doppler flow indices in pregnant women fasting in Ramadan in respect of dehydration in long hot summer days as a marker of hypoperfusion and early renal injury. A cross-sectional observational study was carried out at a University Hospital. Fasting pregnant women and non-fasting age, gravidity and gestational age-matched women were evaluated for hematologic, blood biochemistry and urine parameters in the first and fourth weeks of the Ramadan. Umbilical artery and fRA Doppler flows were studied in each evaluation. Blood urea nitrogen, potassium and hematocrit levels, blood and urine NGAL levels were significantly higher, and fRA Doppler indices increased in fasting women (p < 0.05) during the second visit in the last week of the Ramadan, while non-fasting women had no significant alterations in each evaluation (p > 0.05). Adequate maternal vascular volume is essential for the maintenance of healthy pregnancy. Fasting during the long and hot summer days leads to fluid deprivation and dehydration which was found to be related to subclinical maternal renal dysfunction and increased fRA Doppler indices.
Sakamoto, Shigeyuki; Kiura, Yoshihiro; Okazaki, Takahito; Shinagawa, Katsuhiro; Ishii, Daizo; Ichinose, Nobuhiko; Kurisu, Kaoru
2016-10-01
Carotid artery stenting (CAS) for internal carotid artery (ICA) stenosis with vulnerable plaques is controversial. We analyzed the effect of a dual protection and blood aspiration method during CAS in patients with vulnerable plaques. A total of 111 patients with ICA stenosis underwent CAS using the dual protection (simultaneous flow reversal and distal filter) and blood aspiration method. In 103 of 111 patients, preoperative carotid plaque was estimated by both 3 T MRI and ultrasonography (US). ICA plaques with a high intensity signal on time-of-flight-MR angiography (TOF-MRA) and/or mobile component on US were defined as vulnerable plaques. We assessed major adverse events (MAE) (ie, major stroke, myocardial infarction, and death) and hyperintense spots on diffusion-weighted images (DWI) after CAS. We then evaluated the visible debris captured by dual protection and blood aspiration during CAS. The preoperative ICA plaque on TOF-MRA and US was judged to be vulnerable in 48.5% (50/103 patients). The success rate of the CAS procedure was 100% with no MAE within 30 days. DWI showed small hyperintense spots in 18% (9/50 patients) and 18.9% (10/53 patients) in the vulnerable and non-vulnerable plaque groups, respectively. Visible debris was captured in 68% (34/50 patients) and 45.3% (24/53 patients) in the vulnerable and non-vulnerable plaque groups, respectively (p=0.0286). The combination of dual protection and blood aspiration could provide effective distal embolic protection although vulnerable plaques on TOF-MRA and US had a high incidence of debris during CAS. Thus, CAS using dual protection and blood aspiration is safe in patients with vulnerable plaques. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Application of the Statistical ICA Technique in the DANCE Data Analysis
NASA Astrophysics Data System (ADS)
Baramsai, Bayarbadrakh; Jandel, M.; Bredeweg, T. A.; Rusev, G.; Walker, C. L.; Couture, A.; Mosby, S.; Ullmann, J. L.; Dance Collaboration
2015-10-01
The Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center is used to improve our understanding of the neutron capture reaction. DANCE is a highly efficient 4 π γ-ray detector array consisting of 160 BaF2 crystals which make it an ideal tool for neutron capture experiments. The (n, γ) reaction Q-value equals to the sum energy of all γ-rays emitted in the de-excitation cascades from the excited capture state to the ground state. The total γ-ray energy is used to identify reactions on different isotopes as well as the background. However, it's challenging to identify contribution in the Esum spectra from different isotopes with the similar Q-values. Recently we have tested the applicability of modern statistical methods such as Independent Component Analysis (ICA) to identify and separate different (n, γ) reaction yields on different isotopes that are present in the target material. ICA is a recently developed computational tool for separating multidimensional data into statistically independent additive subcomponents. In this conference talk, we present some results of the application of ICA algorithms and its modification for the DANCE experimental data analysis. This research is supported by the U. S. Department of Energy, Office of Science, Nuclear Physics under the Early Career Award No. LANL20135009.
Yang, Dixon; Cabral, Digna; Gaspard, Emmanuel N; Lipton, Richard B; Rundek, Tatjana; Derby, Carol A
2016-09-01
We sought to describe the relationship between age, sex, and race/ethnicity with transcranial Doppler hemodynamic characteristics from major intracerebral arterial segments in a large elderly population with varying demographics. We analyzed 369 stroke-free participants aged 70 years and older from the Einstein Aging Study. Single-gate, nonimaging transcranial Doppler sonography, a noninvasive sonographic technique that assesses real-time cerebrovascular hemodynamics, was used to interrogate 9 cerebral arterial segments. Individual Doppler spectra and cerebral blood flow velocities were acquired, and the pulsatility index and resistive index were calculated by the device's automated waveform-tracking function. Multiple linear regression models were used to examine the independent associations of age, sex, and race/ethnicity with transcranial Doppler measures, adjusting for hypertension, history of myocardial infarction or revascularization, and history of diabetes. Among enrolled participants, 303 individuals had at least 1 vessel insonated (mean age [SD], 80 [6] years; 63% women; 58% white; and 32% black). With age, transcranial Doppler measures of mean blood flow velocity were significantly decreased in the basilar artery (P = .001) and posterior cerebral artery (right, P = .003; left, P = .02). Pulsatility indices increased in the left middle cerebral artery (P = .01) and left anterior cerebral artery (P = .03), and the resistive index was increased in the left middle cerebral artery (P = .007) with age. Women had higher pulsatility and resistive indices compared to men in several vessels. We report a decreased mean blood flow velocity and weakly increased arterial pulsatility and resistance with aging in a large elderly stroke-free population. These referential trends in cerebrovascular hemodynamics may carry important implications in vascular diseases associated with advanced age, increased risk of cerebrovascular disease, cognitive decline, and dementia.
Potapow, André; Sauter-Louis, Carola; Schmauder, Sandra; Friker, Jutta; Nautrup, Cordula Poulsen; Mehne, Daniel; Petzl, Wolfram; Zerbe, Holm
2010-05-01
The objectives of this preliminary investigation were to evaluate the feasibility of transrectal colour Doppler sonography (TCDS) for determining blood flow of the pudendoepigastric trunk in cows with experimentally induced Escherichia coli Mastitis. Five primiparous Holstein dairy cows, 4-6 months after calving, were examined in two trials. All monitored udder quarters were initially clinically healthy, somatic cell count (SCC) was <50 000 cells/ml and bacteriologically negative. The blood flow of the left and the right pudendoepigastric trunk was described by the blood flow volume (BFV). In the methodological part of the study, the intra-observer precision of the method was evaluated. The coefficients of variation of the BFV were 7.1% for the left and 9.4% for the right pudendoepigastric trunk. The intraclass correlation coefficients of the BFV were 0.99 (P<0.001) for the left and 0.75 (P=0.004) for the right vessel. BFV did not differ significantly between the left and the right side nor between pre- and post-milking nor between oestrus and dioestrus. In the experimental part of the study, significant differences of increasing BFV between 0 and 12 h p.i. (post infectionem) (P=0.043) and decreasing BFV between 12 and 24 h p.i. (P=0.043) were discovered for the pudendoepigastric trunk of the infected right side. In the left-right (control-infection) comparison a significant increase of the right BFV was observed at 12 h p.i. (P=0.043). The difference of an increasing SCC correlated positively with the difference of an increasing BFV between 0 and 12 h p.i. (Spearman's rho=1.00; P=0.043) for the right infected side. It was shown that TCDS is a reproducible technique for investigating pathological mammary blood flow changes at an early stage of acute mastitis.
Elmetwally, Mohammed; Bollwein, Heinrich
2017-01-01
The aim of the present study was to evaluate uterine blood flow (UBF) during the postpartum period in small ruminants. The study involved measures of UBF in 5 ewes and 5 goats during the first 4 weeks after parturition. Transrectal quantification of UBF was assessed by determining the diameter (DM), time averaged mean velocity (TAMEAN), blood flow volume (BFV), blood flow acceleration (ACCE) and pulsatility index (PI) in the uterine arteries ipsilateral to the previously gravid uterine horn(s) at Wk 20 of gestation and every 3days from the day of parturition (D 0) until Day 27 postpartum (D 27). The diameters of the uterine arteries decreased (P<0.01) in both species during the postpartum period. The results revealed decreases (P<0.0001) in BFV, ACCE and TAMEAN, while PI increased during the postpartum period in both sheep and goats. Furthermore, there were positive correlations (P<0.05) between blood flow parameters in sheep and goats, respectively (BFV and DM, r=0.62 and 0.58; BFV and ACCE, r=0.32 and 0.26; BFV and TAMEAN, r=0.51 and 0.37). There were negative correlations (P<0.05) between PI and other parameters (PI and BFV, r=-0.39 and -0.36; PI and DM, r=-0.54 and -0.24; PI and ACCE, r=-0.58 and -0.48; and PI and TAMEAN, r=-0.80 and -0.79) in sheep and goats, respectively. Altogether, these results indicate that non-invasive Doppler ultrasound parameters provide important information toward understanding changes in the vasculature and its perfusion of the uterus during the postpartum period in sheep and goats. Copyright © 2016 Elsevier B.V. All rights reserved.
Separation and reconstruction of high pressure water-jet reflective sound signal based on ICA
NASA Astrophysics Data System (ADS)
Yang, Hongtao; Sun, Yuling; Li, Meng; Zhang, Dongsu; Wu, Tianfeng
2011-12-01
The impact of high pressure water-jet on the different materials target will produce different reflective mixed sound. In order to reconstruct the reflective sound signals distribution on the linear detecting line accurately and to separate the environment noise effectively, the mixed sound signals acquired by linear mike array were processed by ICA. The basic principle of ICA and algorithm of FASTICA were described in detail. The emulation experiment was designed. The environment noise signal was simulated by using band-limited white noise and the reflective sound signal was simulated by using pulse signal. The reflective sound signal attenuation produced by the different distance transmission was simulated by weighting the sound signal with different contingencies. The mixed sound signals acquired by linear mike array were synthesized by using the above simulated signals and were whitened and separated by ICA. The final results verified that the environment noise separation and the reconstruction of the detecting-line sound distribution can be realized effectively.
Prenatal diagnosis of placenta accreta by colour Doppler ultrasonography: 5-year review.
Pongrojpaw, Densak; Chanthasenanont, Athita; Nanthakomon, Tongta; Suwannarurk, Komsun
2014-08-01
To determine the accuracy of colour Doppler ultrasonography to diagnose placenta accreta. The authors reviewed cases of placenta accreta between January, 2008 and December, 2012. Ultrasonographic images consistent with signs ofplacenta accreta (numerous vascular lacunae, loss ofsubplacentalsonolucent space, absent lower uterine segment between bladder-placenta, turbulent or complicated blood flow at the uteroplacental interface) were correlated with findings at the time of surgery and pathologic examination. Over 60 months, 12 cases (0.48/1,000 deliveries) with suspected placenta accreta by ultrasonography were studied. The median gestational age atfirst diagnosis was 24 weeks. All cases had at least one previous cesarean delivery. At surgery, all cases had an adherent placenta requiring hysterectomy (five accreta, three increta, andfourpercreta). Four cases (33%) had accidental tear of urinary bladder Nine cases (75%) required blood transfusions. Colour Doppler ultrasonography appears useful in antenatal diagnosis ofplacenta accreta.
Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang
2016-07-14
Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24-3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309-3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study.
Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi
2004-06-01
Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.
Laser Doppler flowmetry in endodontics: a review.
Jafarzadeh, H
2009-06-01
Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.
Real-time high-velocity resolution color Doppler OCT
NASA Astrophysics Data System (ADS)
Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.
2001-05-01
Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.
Meng, Nana; Liu, Jing; Zhang, Yue; Ma, Jinlan; Li, Hao; Qu, Yi
2014-08-01
To analyze hemodynamic changes in retrobulbar blood vessels using color Doppler imaging in diabetic patients without or with retinopathy. Pertinent publications were retrieved from 3 databases. Changes in peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) of the ophthalmic artery, central retinal artery, and short posterior ciliary artery of diabetic eyes without or with retinopathy and healthy controls were evaluated by color Doppler imaging. Comparisons were conducted in 3 groups: group 1, no retinopathy versus control; group 2, retinopathy versus control; and group 3, no retinopathy versus retinopathy. In group 1, eyes without retinopathy had a significant increase in ophthalmic artery PSV (P = .002), with no heterogeneity (Pheterogeneity = 0.09; inconsistency index [I(2)] = 46%); however, significant reductions in central renal artery PSV and EDV were shown (P = .002; P = .007, respectively), with significant heterogeneity (Pheterogeneity < .00001; I(2) = 85%; Pheterogeneity = .008, I(2) = 68%). A significant increase in ophthalmic artery RI (P = .02) was found in eyes without retinopathy, with heterogeneity (Pheterogeneity = .0009; I(2) = 74%). In group 2, central retinal artery PSV and EDV in eyes with retinopathy decreased significantly (P < 0.00001). Similar results were found for ophthalmic and short posterior ciliary artery EDVs (P= .0003; P< .00001). Ophthalmic artery RI was significantly higher in eyes with retinopathy than controls (P = .0008), with heterogeneity (Pheterogeneity < .00001; I(2) = 84%). In group 3, ophthalmic artery PSV was lower in eyes with retinopathy (P= .04) than eyes without, and central retinal artery PSV and EDV decreased significantly (P = .004; P < .00001) in eyes with retinopathy compared to eyes without. Differences in ophthalmic and central retinal artery RIs were also found in eyes with retinopathy (P = .05; P < .00001). Significant changes in retrobulbar blood flow were found in eyes
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kassouf, Amine, E-mail: amine.kassouf@agroparistech.fr; INRA, UMR1145 Ingénierie Procédés Aliments, 1 Avenue des Olympiades, 91300 Massy; AgroParisTech, UMR1145 Ingénierie Procédés Aliments, 16 rue Claude Bernard, 75005 Paris
2014-11-15
Highlights: • An innovative technique, MIR-ICA, was applied to plastic packaging separation. • This study was carried out on PE, PP, PS, PET and PLA plastic packaging materials. • ICA was applied to discriminate plastics and 100% separation rates were obtained. • Analyses performed on two spectrometers proved the reproducibility of the method. • MIR-ICA is a simple and fast technique allowing plastic identification/classification. - Abstract: Plastic packaging wastes increased considerably in recent decades, raising a major and serious public concern on political, economical and environmental levels. Dealing with this kind of problems is generally done by landfilling and energymore » recovery. However, these two methods are becoming more and more expensive, hazardous to the public health and the environment. Therefore, recycling is gaining worldwide consideration as a solution to decrease the growing volume of plastic packaging wastes and simultaneously reduce the consumption of oil required to produce virgin resin. Nevertheless, a major shortage is encountered in recycling which is related to the sorting of plastic wastes. In this paper, a feasibility study was performed in order to test the potential of an innovative approach combining mid infrared (MIR) spectroscopy with independent components analysis (ICA), as a simple and fast approach which could achieve high separation rates. This approach (MIR-ICA) gave 100% discrimination rates in the separation of all studied plastics: polyethylene terephthalate (PET), polyethylene (PE), polypropylene (PP), polystyrene (PS) and polylactide (PLA). In addition, some more specific discriminations were obtained separating plastic materials belonging to the same polymer family e.g. high density polyethylene (HDPE) from low density polyethylene (LDPE). High discrimination rates were obtained despite the heterogeneity among samples especially differences in colors, thicknesses and surface textures. The
NASA Astrophysics Data System (ADS)
Lu, Z.; Zhou, X.; Junium, C. K.; Sageman, B. B.; Jenkyns, H.
2012-12-01
Periods of catastrophic marine oxygen-depletion are known as Oceanic Anoxic Events (OAEs). The most severe OAE intervals in the geological record can be recognized by both positive and negative δ13C excursions, indicating major changes in the global carbon cycle. However, such geochemical expressions only mark the most significant periods of the OAE, characterized by massive carbon burial and/or injection of isotopically light carbon into the ocean-atmosphere system, effects that typically developed after the initial build-up of anoxic/euxinic conditions in many different basins worldwide. Iodide (I-) and iodate (IO3-) are the thermodynamically stable inorganic forms of iodine in seawater. Iodate is almost completely reduced to iodide in all investigated anoxic basins and OMZs. In a pilot study (Lu et al., 2010, Geology), I/Ca in synthetic calcite recorded iodate concentrations in the medium. This established the potential for I/Ca as a novel redox proxy and it was applied in two carbonate-rich sections recording the early Toarcian OAE (shallow-water carbonate platform site) and the Cenomanian-Turonian OAE 2 (pelagic chalk, Eastbourne, UK). Here we report preliminary I/Ca data from three more Cretaceous OAE 2 sections: Raia del Pedale (Italy), South Ferriby (UK), and Denver (USA) representing the Western Interior Seaway. Raia del Pedale is a shallow-water carbonate platform site. It has lower I/Ca values compared to those of the pelagic sites and the reducing condition lasted relatively longer. I/Ca data from the South Ferriby section have baseline values similar to those at Eastbourne (both are in chalk facies), while positive spikes on the profile may record upwelling episodes. The Western Interior Seaway site shows unique trends in redox conditions during the OAE, consistent with changes in TOC content. These preliminary data indicate that the development of reducing conditions was not synchronous on a global scale and that local environmental factors modified
Applications of Doppler optical coherence tomography
NASA Astrophysics Data System (ADS)
Xu, Zhiqiang
longitudinal resolution and the imaging depth for OCT imaging. Doppler OCT is becoming an increasingly popular field of investigation within optical coherence tomography with potentially important applications in cardiovascular and microfluidic research. We have spent some of the effort on searching for accurate and efficient methods for processing the experimental data. We applied the pseudo Wigner time-frequency distribution method to the data processing of Doppler OCT and compared its performance to that of the short-time Fourier transform method, the Hilbert-based phase-resolved method and the autocorrelation method. We concluded that the pseudo Wigner-distribution signal processing method is overall more precise than other often-used methods in Doppler OCT for the analysis of cross-sectional velocity distributions, especially in the high velocity regime. We also discovered the advantage of using the time-domain instead of the frequency domain for Doppler OCT for some applications where precise Doppler-speed metrology is essential. Based on the fact that the obtained local OCT interference signal is almost a single periodic waveform, we have developed a novel, simple and less time-consuming processing method based on the zero-crossing points in an OCT signal for the measurement of the Doppler frequency in a laminar flow. This method was compared to other processing approaches currently used in Doppler OCT. The results show that in the case of laminar flow, the zero-crossing method gives the more precise results, especially in the higher velocity regime with a substantial economy in processing time and an increase in dynamic range which can reach 70 dB. This feature becomes a major advantage in metrology if one wants to measure velocities over several orders of magnitude. We have applied this technique to some real flow models and the preliminary results on flow velocity distributions obtained in the case of a microfluidic circuit and in that of a phantom of a blood vessel
Nelson, John Stuart; Milner, Thomas Edward; Chen, Zhongping
1999-01-01
Optical Doppler tomography permits imaging of fluid flow velocity in highly scattering media. The tomography system combines Doppler velocimetry with high spatial resolution of partially coherent optical interferometry to measure fluid flow velocity at discrete spatial locations. Noninvasive in vivo imaging of blood flow dynamics and tissue structures with high spatial resolutions of the order of 2 to 10 microns is achieved in biological systems. The backscattered interference signals derived from the interferometer may be analyzed either through power spectrum determination to obtain the position and velocity of each particle in the fluid flow sample at each pixel, or the interference spectral density may be analyzed at each frequency in the spectrum to obtain the positions and velocities of the particles in a cross-section to which the interference spectral density corresponds. The realized resolutions of optical Doppler tomography allows noninvasive in vivo imaging of both blood microcirculation and tissue structure surrounding the vessel which has significance for biomedical research and clinical applications.
NASA Astrophysics Data System (ADS)
Jenkins, Michael W.; Peterson, Lindsy; Gu, Shi; Gargesha, Madhusudhana; Wilson, David L.; Watanabe, Michiko; Rollins, Andrew M.
2010-11-01
Hemodynamics is thought to play a major role in heart development, yet tools to quantitatively assess hemodynamics in the embryo are sorely lacking. The especially challenging analysis of hemodynamics in the early embryo requires new technology. Small changes in blood flow could indicate when anomalies are initiated even before structural changes can be detected. Furthermore, small changes in the early embryo that affect blood flow could lead to profound abnormalities at later stages. We present a demonstration of 4-D Doppler optical coherence tomography (OCT) imaging of structure and flow, and present several new hemodynamic measurements on embryonic avian hearts at early stages prior to the formation of the four chambers. Using 4-D data, pulsed Doppler measurements could accurately be attained in the inflow and outflow of the heart tube. Also, by employing an en-face slice from the 4-D Doppler image set, measurements of stroke volume and cardiac output are obtained without the need to determine absolute velocity. Finally, an image plane orthogonal to the blood flow is used to determine shear stress by calculating the velocity gradient normal to the endocardium. Hemodynamic measurements will be crucial to identifying genetic and environmental factors that lead to congenital heart defects.
Wang, Nizhuan; Chang, Chunqi; Zeng, Weiming; Shi, Yuhu; Yan, Hongjie
2017-01-01
Independent component analysis (ICA) has been widely used in functional magnetic resonance imaging (fMRI) data analysis to evaluate functional connectivity of the brain; however, there are still some limitations on ICA simultaneously handling neuroimaging datasets with diverse acquisition parameters, e.g., different repetition time, different scanner, etc. Therefore, it is difficult for the traditional ICA framework to effectively handle ever-increasingly big neuroimaging datasets. In this research, a novel feature-map based ICA framework (FMICA) was proposed to address the aforementioned deficiencies, which aimed at exploring brain functional networks (BFNs) at different scales, e.g., the first level (individual subject level), second level (intragroup level of subjects within a certain dataset) and third level (intergroup level of subjects across different datasets), based only on the feature maps extracted from the fMRI datasets. The FMICA was presented as a hierarchical framework, which effectively made ICA and constrained ICA as a whole to identify the BFNs from the feature maps. The simulated and real experimental results demonstrated that FMICA had the excellent ability to identify the intergroup BFNs and to characterize subject-specific and group-specific difference of BFNs from the independent component feature maps, which sharply reduced the size of fMRI datasets. Compared with traditional ICAs, FMICA as a more generalized framework could efficiently and simultaneously identify the variant BFNs at the subject-specific, intragroup, intragroup-specific and intergroup levels, implying that FMICA was able to handle big neuroimaging datasets in neuroscience research.
Pinheiro, Luiza; Brito, Carla Ivo; Oliveira, Adilson de; Pereira, Valéria Cataneli; Cunha, Maria de Lourdes Ribeiro de Souza da
2016-09-01
Infections with coagulase-negative staphylococci are often related to biofilm formation. This study aimed to detect biofilm formation and biofilm-associated genes in blood culture isolates of Staphylococcus epidermidis and S. haemolyticus. Half (50.6%) of the 85 S. epidermidis isolates carried the icaAD genes and 15.3% the bhp gene, while these numbers were 42.9% and 0 for S. haemolyticus, respectively. According to the plate test, 30 S. epidermidis isolates were biofilm producers and 40% of them were strongly adherent, while only one (6%) of the 17 S. haemolyticus biofilm-producing isolates exhibited a strongly adherent biofilm. The concomitant presence of icaA and icaD was significantly associated with the plate and tube test results (P ≤ 0.0004). The higher frequency of icaA in S. epidermidis and of icaD in S. haemolyticus is correlated with the higher biofilm-producing capacity of the former since, in contrast to IcaD, IcaA activity is sufficient to produce small amounts of polysaccharide. Although this study emphasizes the importance of icaAD and bhp for biofilm formation in S. epidermidis, other mechanisms seem to be involved in S. haemolyticus. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tan, Bingyao; Mason, Erik; MacLellan, Ben; Bizheva, Kostadinka
2017-02-01
Visually evoked changes of retinal blood flow can serve as an important research tool to investigate eye disease such as glaucoma and diabetic retinopathy. In this study we used a combined, research-grade, high-resolution Doppler OCT+ERG system to study changes in the retinal blood flow (RBF) and retinal neuronal activity in response to visual stimuli of different intensities, durations and type (flicker vs single flash). Specifically, we used white light stimuli of 10 ms and 200 ms single flash, 1s and 2s for flickers stimuli of 20% duty cycle. The study was conducted in-vivo in pigmented rats. Both single flash (SF) and flicker stimuli caused increase in the RBF. The 10 ms SF stimulus did not generate any consistent measurable response, while the 200 ms SF of the same intensity generated 4% change in the RBF peaking at 1.5 s after the stimulus onset. Single flash stimuli introduced 2x smaller change in RBF and 30% earlier RBF peak response compared to flicker stimuli of the same intensity and duration. Doubling the intensity of SF or flicker stimuli increased the RBF peak magnitude by 1.5x. Shortening the flicker stimulus duration by 2x increased the RBF recovery rate by 2x, however, had no effect on the rate of RBF change from baseline to peak.
FPGA implementation of ICA algorithm for blind signal separation and adaptive noise canceling.
Kim, Chang-Min; Park, Hyung-Min; Kim, Taesu; Choi, Yoon-Kyung; Lee, Soo-Young
2003-01-01
An field programmable gate array (FPGA) implementation of independent component analysis (ICA) algorithm is reported for blind signal separation (BSS) and adaptive noise canceling (ANC) in real time. In order to provide enormous computing power for ICA-based algorithms with multipath reverberation, a special digital processor is designed and implemented in FPGA. The chip design fully utilizes modular concept and several chips may be put together for complex applications with a large number of noise sources. Experimental results with a fabricated test board are reported for ANC only, BSS only, and simultaneous ANC/BSS, which demonstrates successful speech enhancement in real environments in real time.
Ramiar, Abas; Larimi, Morsal Momenti; Ranjbar, Ali Akbar
2017-01-01
Hemodynamic factors, such as Wall Shear Stress (WSS), play a substantial role in arterial diseases. In the larger arteries, such as the carotid artery, interaction between the vessel wall and blood flow affects the distribution of hemodynamic factors. The fluid is considered to be non-Newtonian, whose flow is governed by the equation of a second-grade viscoelastic fluid and the effects of viscoelastic on blood flow in carotid artery is investigated. Pulsatile flow studies were carried out in a 3D model of carotid artery. The governing equations were solved using finite volume C++ based on open source code, OpenFOAM. To describe blood flow, conservation of mass and momentum, a constitutive relation of simplified Phan-Thien-Tanner (sPTT), and appropriate relations were used to explain shear thinning behavior. The first recirculation was observed at t = 0.2 s, in deceleration phase. In the acceleration phase from t = 0.3 s to t = 0.5 s, vortex and recirculation sizes in bulb regions in both ECA and ICA gradually increased. As is observed in the line graphs based on extracted data from ICA, at t = 0.2 s, τyy is the maximum amount of wall shear stress and τxy the minimum one. The maximum shear stress occurred in the inner side of the main branch (inner side of ICA and ECA) because the velocity of blood flow in the inner side of the bulb region was maximum due to the created recirculation zone in the opposite side in this area. The rheology of blood flow and shear stress in various important parts (the area that are in higher rates of WSS such as bifurcation region and the regions after bulb areas in both branches, Line1-4 in Fig. 7) were also analyzed. The investigation of velocity stream line, velocity profile and shear stress in various sections of carotid artery showed that the maximum shear stress occurred in acceleration phase and in the bifurcation region between ECA and ICA which is due to velocity gradients and changes in thinning behavior of blood and
Effects of sodium citrate, citric acid and lactic acid on human blood coagulation.
Scaravilli, Vittorio; Di Girolamo, Luca; Scotti, Eleonora; Busana, Mattia; Biancolilli, Osvaldo; Leonardi, Patrizia; Carlin, Andrea; Lonati, Caterina; Panigada, Mauro; Pesenti, Antonio; Zanella, Alberto
2018-05-01
Citric acid infusion in extracorporeal blood may allow concurrent regional anticoagulation and enhancement of extracorporeal CO 2 removal. Effects of citric acid on human blood thromboelastography and aggregometry have never been tested before. In this in vitro study, citric acid, sodium citrate and lactic acid were added to venous blood from seven healthy donors, obtaining concentrations of 9 mEq/L, 12 mEq/L and 15 mEq/L. We measured gas analyses, ionized calcium (iCa ++ ) concentration, activated clotting time (ACT), thromboelastography and multiplate aggregometry. Repeated measure analysis of variance was used to compare the acidifying and anticoagulant properties of the three compounds. Sodium citrate did not affect the blood gas analysis. Increasing doses of citric and lactic acid progressively reduced pH and HCO 3 - and increased pCO 2 (p<0.001). Sodium citrate and citric acid similarly reduced iCa ++ , from 0.39 (0.36-0.39) and 0.35 (0.33-0.36) mmol/L, respectively, at 9 mEq/L to 0.20 (0.20-0.21) and 0.21 (0.20-0.23) mmol/L at 15 mEq/L (p<0.001). Lactic acid did not affect iCa ++ (p=0.07). Sodium citrate and citric acid similarly incremented the ACT, from 234 (208-296) and 202 (178-238) sec, respectively, at 9 mEq/L, to >600 sec at 15 mEq/L (p<0.001). Lactic acid did not affect the ACT values (p=0.486). Sodium citrate and citric acid similarly incremented R-time and reduced α-angle and maximum amplitude (MA) (p<0.001), leading to flat-line thromboelastograms at 15 mEq/L. Platelet aggregometry was not altered by any of the three compounds. Citric acid infusions determine acidification and anticoagulation of blood similar to lactic acid and sodium citrate, respectively.
Carod Artal, Francisco Javier; Vázquez Cabrera, Carolina; Horan, Thomas Anthony
2004-01-01
Transcranial Doppler ultrasonography (TCD) permits the assessment of cognitively induced cerebral blood flow velocity (BFV) changes. We sought to investigate the lateralization of BFV acceleration induced by auditory stimulation and speech in a normal population. TCD monitoring of BFV in the middle cerebral arteries (MCA) was performed in 30 normal right-handed volunteers (average age = 31.7 years). Noise stimulation, speech, and instrumental music were administered during 60 sec to both ears by means of earphones. Auditory stimulation induced a significant BFV increase in the ipsilateral MCA compared to BFV during the preceding rest periods. Left MCA BFV increased by an average of 7.1% (noise), 8.4% (language), and 5.2% (melody) over baseline values, and right MCA BFV increased 5.1%, 3.1%, and 4.2%, respectively. Speech stimulation produced a significant increase in BFV in the left hemisphere MCA (from 49.86 to 54.03 cm/sec; p < .0001). Left MCA BFV response to speech stimulation may reflect the dominance of the left hemisphere in language processing by right-handed individuals. Due to the high temporal resolution of TCD we were able show a habituation effect during the 60-sec stimulation period.
Vessel packaging effect in laser speckle contrast imaging and laser Doppler imaging.
Fredriksson, Ingemar; Larsson, Marcus
2017-10-01
Laser speckle-based techniques are frequently used to assess microcirculatory blood flow. Perfusion estimates are calculated either by analyzing the speckle fluctuations over time as in laser Doppler flowmetry (LDF), or by analyzing the speckle contrast as in laser speckle contrast imaging (LSCI). The perfusion estimates depend on the amount of blood and its speed distribution. However, the perfusion estimates are commonly given in arbitrary units as they are nonlinear and depend on the magnitude and the spatial distribution of the optical properties in the tissue under investigation. We describe how the spatial confinement of blood to vessels, called the vessel packaging effect, can be modeled in LDF and LSCI, which affect the Doppler power spectra and speckle contrast, and the underlying bio-optical mechanisms for these effects. As an example, the perfusion estimate is reduced by 25% for LDF and often more than 50% for LSCI when blood is located in vessels with an average diameter of 40 μm, instead of being homogeneously distributed within the tissue. This significant effect can be compensated for only with knowledge of the average diameter of the vessels in the tissue. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Millet, C; Roustit, M; Blaise, S; Cracowski, J L
2011-09-01
We tested the linearity between skin blood flux recorded with laser speckle contrast imaging (LSCI) and laser Doppler imaging (LDI), comparing different ways of expressing data. A secondary objective was to test within-subject variability of baseline flux with the two techniques. We performed local heating at 36, 39, 42, and 44°C on the forearm of healthy volunteers, and measured cutaneous blood flux with LDI and LSCI. Biological zero (BZ) was obtained by occluding the brachial artery. We expressed data as raw arbitrary perfusion units (APUs) and as a percentage increase from baseline (%BL), with and without subtracting BZ. Inter-site variability was expressed as a within subject coefficient of variation (CV). Twelve participants were enrolled. Inter-site variability at baseline was lower with LSCI (CV=9.2%) than with LDI (CV=20.7%). We observed an excellent correlation between both techniques when data were expressed as raw APUs or APU-BZ (R=0.90; p<0.001). The correlation remained correct for %BL (R=0.77, p<0.001), but decreased for %BL-BZ (R=0.44, p=0.003). Bland-Altman plots revealed a major proportional bias between the two techniques. This study suggests that skin blood flux measured with LSCI is linearly related to the LDI signal over a wide range of perfusion. Subtracting BZ does not affect this linearity but introduces variability in baseline flux, thus decreasing the correlation when data are expressed as a function of baseline. Finally, systematic bias makes it impossible to assimilate arbitrary perfusion units provided by the two systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Hirata, K; Nagasaka, T; Noda, Y
1988-01-01
This study was made to see whether changes in blood flow through the capillaries and arteriovenous anastomoses (AVA's) of the human finger can be measured by noninvasive flowmetry. Total finger blood flow (FBF) was measured by venous occlusion plethysmography; blood flow was measured by a laser-Doppler flowmeter (ADVANCE, ALF-2100, Tokyo, Japan) using probes with optic fiber separations of 0.3 mm (LDF-0.3) and 0.7 mm (LDF-0.7). The maximum sensitivities for LDF-0.3 and LDF-0.7 were at depths of 0.8 and 1.2 mm from the tissue surface respectively. Two series of experiments were performed on separate days. In the first series the test hand was immersed in a water bath whose temperature (Tw) was 25 degrees C at an ambient temperature (Ta) of 25 degrees C. Tw was raised to 35 degrees C (local hand warming), which was then followed by an increase in Ta to 35 degrees C (whole body warming). FBF, LDF-0.3, and LDF-0.7 increased during these thermal stimulations. However, the relationship of FBF to LDF-0.3 showed two different regression lines. In contrast, the relationship of FBF to LDF-0.7 showed a single regression line. In the second series, with Ta at 35 degrees C, the test hand was immersed in a water bath at Tw 35 degrees C. Tw was then raised every 10 min by 2 degrees C steps from 35 to 41 degrees C. At Tw 39-41 degrees C, FBF and LDF-0.7 in the test hand were significantly decreased compared with those at Tw 35 degrees C.(ABSTRACT TRUNCATED AT 250 WORDS)
Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang
2016-01-01
Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24–3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309–3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study. PMID:27412818
A Brief Background of the ICA (International Communication Association) Audit.
ERIC Educational Resources Information Center
Krivonos, Paul D.
This paper examines the International Communication Association (ICA) audit, the aim of which is to establish an integrated communication audit system and a multimethod approach to the auditing of the communication of an organization. Many of an organization's communication variables and concepts are examined so that strengths and weaknesses in…
NASA Astrophysics Data System (ADS)
Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo
2018-02-01
Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L = N = 9), i.e. ⩽0.24 cm s-1, for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L
Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo
2018-02-09
Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L = N = 9), i.e. ⩽0.24 cm s -1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L
In vivo lateral blood flow velocity measurement using speckle size estimation.
Xu, Tiantian; Hozan, Mohsen; Bashford, Gregory R
2014-05-01
In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is "smeared") if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method
Assessment of Spectral Doppler in Preclinical Ultrasound Using a Small-Size Rotating Phantom
Yang, Xin; Sun, Chao; Anderson, Tom; Moran, Carmel M.; Hadoke, Patrick W.F.; Gray, Gillian A.; Hoskins, Peter R.
2013-01-01
Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°–80°. However, for angles of 10°–40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound. PMID:23711503
Jespersen, Bente; Møldrup, Ulla; Keller, Anna K.
2017-01-01
Background Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion. Methods In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls. Results All parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed. Conclusions We developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended. PMID:28542429
Microprobes For Blood Flow Measurements In Tissue And Small Vessels
NASA Astrophysics Data System (ADS)
Oberg, P. A.; Salerud, E. G.
1988-04-01
Laser Doppler flowmetry is a method for the continuous and non-invasive recording of tissue blood flow. The method has already proved to be advantageous in a number of clinical as well as theoretical medical disciplines. In dermatology, plastic- and gastrointestinal surgery laser Doppler measurements have substantially contributed to increase knowledge of microvascular perfusion. In experimental medicine, the method has been used in the study of a great variety of microvascular problems. Spontaneous rhythmical variations, spatial and temporal fluctuations in human skin blood flow are mentioned as examples of problem areas in which new knowledge has been generated. The method has facilitated further investigations of the nature of spongeous bone blood flow, testis and kidney cortex blood flow. Recently we have showed that a variant of the laser Doppler method principle, using a single optical fiber, can be advantageous in deep tissue measurements. With this method laser light is transmitted bidirectionally in a single fiber. The tissue trauma which affects blood flow can be minimized by introducing small diameter fibers (0.1-0.5 mm). A special set-up utilizing the same basic principle has been used for the recording of blood flow in small vessels.
Wirth, K; Zielinski, P; Trinter, T; Stahl, R; Mück, F; Reiser, M; Wirth, S
2016-08-01
In hospitals, the radiological services provided to non-privately insured in-house patients are mostly distributed to requesting disciplines through internal cost allocation (ICA). In many institutions, computed tomography (CT) is the modality with the largest amount of allocation credits. The aim of this work is to compare the ICA to respective DRG (Diagnosis Related Groups) shares for diagnostic CT services in a university hospital setting. The data from four CT scanners in a large university hospital were processed for the 2012 fiscal year. For each of the 50 DRG groups with the most case-mix points, all diagnostic CT services were documented including their respective amount of GOÄ allocation credits and invoiced ICA value. As the German Institute for Reimbursement of Hospitals (InEK) database groups the radiation disciplines (radiology, nuclear medicine and radiation therapy) together and also lacks any modality differentiation, the determination of the diagnostic CT component was based on the existing institutional distribution of ICA allocations. Within the included 24,854 cases, 63,062,060 GOÄ-based performance credits were counted. The ICA relieved these diagnostic CT services by € 819,029 (single credit value of 1.30 Eurocent), whereas accounting by using DRG shares would have resulted in € 1,127,591 (single credit value of 1.79 Eurocent). The GOÄ single credit value is 5.62 Eurocent. The diagnostic CT service was basically rendered as relatively inexpensive. In addition to a better financial result, changing the current ICA to DRG shares might also mean a chance for real revenues. However, the attractiveness considerably depends on how the DRG shares are distributed to the different radiation disciplines of one institution.
Pulse Doppler ultrasound as a tool for the diagnosis of chronic testicular dysfunction in stallions
Ortiz-Rodriguez, Jose M.; Anel-Lopez, Luis; Martín-Muñoz, Patricia; Álvarez, Mercedes; Gaitskell-Phillips, Gemma; Anel, Luis; Rodríguez-Medina, Pedro; Peña, Fernando J.
2017-01-01
Testicular function is particularly susceptible to vascular insult, resulting in a negative impact on sperm production and quality of the ejaculate. A prompt diagnosis of testicular dysfunction enables implementation of appropriate treatment, hence improving fertility forecasts for stallions. The present research aims to: (1) assess if Doppler ultrasonography is a good tool to diagnose stallions with testicular dysfunction; (2) to study the relationship between Doppler parameters of the testicular artery and those of sperm quality assessed by flow cytometry and (3) to establish cut off values to differentiate fertile stallions from those with pathologies causing testicular dysfunction. A total of 10 stallions (n: 7 healthy stallions and n: 3 sub-fertile stallions) were used in this study. Two ejaculates per stallion were collected and preserved at 5°C in a commercial extender. The semen was evaluated at T0, T24 and T48h by flow cytometry. Integrity and viability of sperm (YoPro®-1/EthD-1), mitochondrial activity (MitoTracker® Deep Red FM) and the DNA fragmentation index (Sperm Chromatin Structure Assay) were assessed. Doppler parameters were measured at three different locations on the testicular artery (Supratesticular artery (SA); Capsular artery (CA) and Intratesticular artery (IA)). The Doppler parameters calculated were: Resistive Index (RI), Pulsatility Index (PI), Peak Systolic Velocity (PSV), End Diastolic Velocity (EDV), Time Average Maximum Velocity (TAMV), Total Arterial Blood Flow (TABF) and TABF rate. The capsular artery was the most reliable location to carry out spectral Doppler assessment, since blood flow parameters of this artery were most closely correlated with sperm quality parameters. Significant differences in all the Doppler parameters studied were observed between fertile and subfertile stallions (p ≤ 0.05). The principal components analysis assay determined that fertile stallions are characterized by high EDV, TAMV, TABF and TABF rate
Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel
2012-01-01
To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.
Zuhur, Sayid Shafi; Özel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Çil, Esra; Altuntas, Yüksel
2012-01-01
OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age- and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. PMID:22358236
Endovascular revascularization results in IMS III: intracranial ICA and M1 occlusions.
Tomsick, Thomas A; Yeatts, Sharon D; Liebeskind, David S; Carrozzella, Janice; Foster, Lydia; Goyal, Mayank; von Kummer, Ruediger; Hill, Michael D; Demchuk, Andrew M; Jovin, Tudor; Yan, Bernard; Zaidat, Osama O; Schonewille, Wouter; Engelter, Stefan; Martin, Renee; Khatri, Pooja; Spilker, Judith; Palesch, Yuko Y; Broderick, Joseph P
2015-11-01
Interventional Management of Stroke III did not show that combining IV recombinant tissue plasminogen activator (rt-PA) with endovascular therapies (EVTs) is better than IV rt-PA alone. To report efficacy and safety results for EVT of intracranial internal carotid artery (ICA) and middle cerebral artery trunk (M1) occlusion. Five revascularization methods for persistent occlusions after IV rt-PA treatment were evaluated for prespecified primary and secondary endpoints, after accounting for differences in key baselines variables using propensity scores. Revascularization was scored using the arterial occlusive lesion (AOL) and the modified Thrombolysis in Cerebral Ischemia (mTICI) scores. EVT of 200 subjects with intracranial ICA or M1 occlusion resulted in 81.5% AOL 2-3 recanalization, in addition to 76% mTICI 2-3 and 42.5% mTICI 2b-3 reperfusion. Adverse events included symptomatic intracranial hemorrhage (SICH) (8.0%), vessel perforations (1.5%), and new emboli (14.9%). EVT techniques used were standard microcatheter n=51; EKOS n=14; Merci n=77; Penumbra n=39; Solitaire n=4; multiple n=15. Good clinical outcome was associated with both TICI 2-3 and TICI 2b-3 reperfusion. Neither modified Rankin scale (mRS) 0-2 (28.5%), nor 90-day mortality (28.5%), nor asymptomatic ICH (36.0%) differed among revascularization methods after propensity score adjustment for subjects with intracranial ICA or M1 occlusion. Good clinical outcome was associated with good reperfusion for ICA and M1 occlusion. No significant differences in efficacy or safety among revascularization methods were demonstrated after adjustment. Lack of high-quality reperfusion, adverse events, and prolonged time to treatment contributed to lower-than-expected mRS 0-2 outcomes and study futility compared with IV rt-PA. NCT00359424. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
2013-09-01
measure blood flow velocity in the MCA and ICA of patients with known vasospasm, as compared to standard TCD run by a trained neurosonographer...a trained neurosonographer. (Q1-Q10 out of 12 quarters) Task 1: Get approval for the human subjects study (Q1-2). This study will involve up to 128...Heinemann; 1999:109–128. 2. Aaslid R, Nornes H. Musical murmurs in human cerebral arteries after subarachnoid hemorrhage. J Neurosurg 1984; 60:32–36
Vector Doppler: spatial sampling analysis and presentation techniques for real-time systems
NASA Astrophysics Data System (ADS)
Capineri, Lorenzo; Scabia, Marco; Masotti, Leonardo F.
2001-05-01
The aim of the vector Doppler (VD) technique is the quantitative reconstruction of a velocity field independently of the ultrasonic probe axis to flow angle. In particular vector Doppler is interesting for studying vascular pathologies related to complex blood flow conditions. Clinical applications require a real-time operating mode and the capability to perform Doppler measurements over a defined volume. The combination of these two characteristics produces a real-time vector velocity map. In previous works the authors investigated the theory of pulsed wave (PW) vector Doppler and developed an experimental system capable of producing off-line 3D vector velocity maps. Afterwards, for producing dynamic velocity vector maps, we realized a new 2D vector Doppler system based on a modified commercial echograph. The measurement and presentation of a vector velocity field requires a correct spatial sampling that must satisfy the Shannon criterion. In this work we tackled this problem, establishing a relationship between sampling steps and scanning system characteristics. Another problem posed by the vector Doppler technique is the data representation in real-time that should be easy to interpret for the physician. With this in mine we attempted a multimedia solution that uses both interpolated images and sound to represent the information of the measured vector velocity map. These presentation techniques were experimented for real-time scanning on flow phantoms and preliminary measurements in vivo on a human carotid artery.
Stable Scalp EEG Spatiospectral Patterns Across Paradigms Estimated by Group ICA.
Labounek, René; Bridwell, David A; Mareček, Radek; Lamoš, Martin; Mikl, Michal; Slavíček, Tomáš; Bednařík, Petr; Baštinec, Jaromír; Hluštík, Petr; Brázdil, Milan; Jan, Jiří
2018-01-01
Electroencephalography (EEG) oscillations reflect the superposition of different cortical sources with potentially different frequencies. Various blind source separation (BSS) approaches have been developed and implemented in order to decompose these oscillations, and a subset of approaches have been developed for decomposition of multi-subject data. Group independent component analysis (Group ICA) is one such approach, revealing spatiospectral maps at the group level with distinct frequency and spatial characteristics. The reproducibility of these distinct maps across subjects and paradigms is relatively unexplored domain, and the topic of the present study. To address this, we conducted separate group ICA decompositions of EEG spatiospectral patterns on data collected during three different paradigms or tasks (resting-state, semantic decision task and visual oddball task). K-means clustering analysis of back-reconstructed individual subject maps demonstrates that fourteen different independent spatiospectral maps are present across the different paradigms/tasks, i.e. they are generally stable.
Kmeans-ICA based automatic method for ocular artifacts removal in a motorimagery classification.
Bou Assi, Elie; Rihana, Sandy; Sawan, Mohamad
2014-01-01
Electroencephalogram (EEG) recordings aroused as inputs of a motor imagery based BCI system. Eye blinks contaminate the spectral frequency of the EEG signals. Independent Component Analysis (ICA) has been already proved for removing these artifacts whose frequency band overlap with the EEG of interest. However, already ICA developed methods, use a reference lead such as the ElectroOculoGram (EOG) to identify the ocular artifact components. In this study, artifactual components were identified using an adaptive thresholding by means of Kmeans clustering. The denoised EEG signals have been fed into a feature extraction algorithm extracting the band power, the coherence and the phase locking value and inserted into a linear discriminant analysis classifier for a motor imagery classification.
Kalotka-Bratek, H; Drobinski, G; Klimczak, K; Busquet, P; Fraysse, J B; Bejean-Lebuisson, A; Grosgogeat, Y
1989-02-01
In 20 patients with pure aortic regurgitation we studied the relationship between the severity of regurgitation, as assessed haemodynamically by the percentage of leakage (%L), and the half-pressure (T 1/2 P) and half-velocity (T 1/2 V) times, as obtained from doppler aortic blood velocity curves, taking into account the rigidity of the systemic vascular circuit characterized by the pressure wave propagation velocity (PWPV). The systemic arterial circuit was supple in 14 patients (PWPV less than 7.5 m/sec) and rigid in 6 patients (PWPV greater than 7.5 m/sec). The regression slopes between %L and T 1/2 P and between %L and T 1/2 V were calculated with their confidence limits in the 14 patients with supple arteries. The 6 patients with rigid arteries fitted into this nomogram, thus demonstrating that systemic arterial rigidity makes no difference in the relationship between %L and doppler indices. The half-velocity and half-pressure times measured by doppler ultrasound were acquired from a velocity signal directly determined by the aortic regurgitation, without any detectable effect of vascular circuit rigidity. Being equivalent by nature to the signal decrease time constant, they are independent of the absolute protodiastolic value of diastolic pressure gradient or blood flow velocity. For this reason these two doppler parameters are reliable to evaluate the severity of aortic regurgitation.
Dual-Doppler Feasibility Study
NASA Technical Reports Server (NTRS)
Huddleston, Lisa L.
2012-01-01
When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any
Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions
Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati
2011-01-01
Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940
Doppler aortic flow velocity measurement in healthy children.
Sohn, S.; Kim, H. S.
2001-01-01
To determine normal values for Doppler parameters of left ventricular function, ascending aortic blood flow velocity was measured by pulsed wave Doppler echocardiography in 63 healthy children with body surface area (BSA) < 1 m(2) (age < 10 yr). Peak velocity was independent of sex, but increased with body size. Mean acceleration was related to peak velocity (r = 0.75, p < 0.0001). Both stroke distance and ejection time had strong negative correlations with heart rate and positive correlations with BSA, suggesting that these parameters should be evaluated in relation to heart rate and body size. Mean intra- and interobserver variability for peak velocity, ejection time, stroke and minute distance ranged from 3 to 7%, whereas variability for acceleration time was 9 to 13%. These data may be used as reference values for the assessment of hemodynamic states in young children with cardiac disease. PMID:11306737
Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I
2017-04-01
OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.
Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja)
de Moraes, Wanderlei; Ferreira, Thiago A.C.; Somma, André T.; Cubas, Zalmir S.; Moore, Bret A.; Montiani-Ferreira, Fabiano
2017-01-01
Twenty harpy eagles (Harpia harpyja) without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI) and pulsatility index (PI) were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation. PMID:28540254
Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.
Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A
1993-05-01
Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.
Three-dimensional color Doppler imaging of the carotid artery
NASA Astrophysics Data System (ADS)
Picot, Paul A.; Rickey, Daniel W.; Mitchell, Ross; Rankin, Richard N.; Fenster, Aaron
1991-05-01
Stroke is the third leading cause of death in the United States. It is caused by ischemic injury to the brain, usually resulting from emboli from atherosclerotic plaques. The carotid bifurcation in humans is prone to atherosclerotic disease and is a site where emboli may originate. Currently, carotid stenoses are evaluated by non-invasive duplex Doppler ultrasound, with preoperative verification by intra-arterial angiography. We have developed a system that uses a color Doppler ultrasound imaging system to acquire in-vivo 3-D color Doppler images of the human carotid artery, with the aim of increasing the diagnostic accuracy of ultrasound and decreasing the use of angiography for verification. A clinical TL Ultramark 9 color Doppler ultrasound system was modified by mounting the hand-held ultrasound scan head on a motor-driven translation stage. The stage allows planar ultrasound images to be acquired over 45 mm along the neck between the clavicle and the mandible. A 3- D image is acquired by digitizing, in synchrony with the cardiac cycle, successive color ultrasound video images as the scan head is stepped along the neck. A complete volume set of 64 frames, comprising some 15 megabytes of data, requires approximately 2 minutes to acquire. The volume image is reformatted and displayed on a Sun 4/360 workstation equipped with a TAAC-1 graphics accelerator. The 3-D image may be manipulated in real time to yield the best view of blood flow in the bifurcation.
Monakhova, Yulia B; Mushtakova, Svetlana P
2017-05-01
A fast and reliable spectroscopic method for multicomponent quantitative analysis of targeted compounds with overlapping signals in complex mixtures has been established. The innovative analytical approach is based on the preliminary chemometric extraction of qualitative and quantitative information from UV-vis and IR spectral profiles of a calibration system using independent component analysis (ICA). Using this quantitative model and ICA resolution results of spectral profiling of "unknown" model mixtures, the absolute analyte concentrations in multicomponent mixtures and authentic samples were then calculated without reference solutions. Good recoveries generally between 95% and 105% were obtained. The method can be applied to any spectroscopic data that obey the Beer-Lambert-Bouguer law. The proposed method was tested on analysis of vitamins and caffeine in energy drinks and aromatic hydrocarbons in motor fuel with 10% error. The results demonstrated that the proposed method is a promising tool for rapid simultaneous multicomponent analysis in the case of spectral overlap and the absence/inaccessibility of reference materials.
NASA Astrophysics Data System (ADS)
Jing, Ya-Bing; Liu, Chang-Wen; Bi, Feng-Rong; Bi, Xiao-Yang; Wang, Xia; Shao, Kang
2017-07-01
Numerous vibration-based techniques are rarely used in diesel engines fault diagnosis in a direct way, due to the surface vibration signals of diesel engines with the complex non-stationary and nonlinear time-varying features. To investigate the fault diagnosis of diesel engines, fractal correlation dimension, wavelet energy and entropy as features reflecting the diesel engine fault fractal and energy characteristics are extracted from the decomposed signals through analyzing vibration acceleration signals derived from the cylinder head in seven different states of valve train. An intelligent fault detector FastICA-SVM is applied for diesel engine fault diagnosis and classification. The results demonstrate that FastICA-SVM achieves higher classification accuracy and makes better generalization performance in small samples recognition. Besides, the fractal correlation dimension and wavelet energy and entropy as the special features of diesel engine vibration signal are considered as input vectors of classifier FastICA-SVM and could produce the excellent classification results. The proposed methodology improves the accuracy of feature extraction and the fault diagnosis of diesel engines.
A real-time device for converting Doppler ultrasound audio signals into fluid flow velocity
Hogeman, Cynthia S.; Koch, Dennis W.; Krishnan, Anandi; Momen, Afsana; Leuenberger, Urs A.
2010-01-01
A Doppler signal converter has been developed to facilitate cardiovascular and exercise physiology research. This device directly converts audio signals from a clinical Doppler ultrasound imaging system into a real-time analog signal that accurately represents blood flow velocity and is easily recorded by any standard data acquisition system. This real-time flow velocity signal, when simultaneously recorded with other physiological signals of interest, permits the observation of transient flow response to experimental interventions in a manner not possible when using standard Doppler imaging devices. This converted flow velocity signal also permits a more robust and less subjective analysis of data in a fraction of the time required by previous analytic methods. This signal converter provides this capability inexpensively and requires no modification of either the imaging or data acquisition system. PMID:20173048
Skin blood flow: a comparison of transcutaneous oximetry and laser Doppler flowmetry.
Allen, P I; Goldman, M
1987-10-01
In normal limbs skin blood flow (SBF) falls on standing, but in ischaemic limbs there is a characteristic blush on dependancy. We studied the effect of changing posture in a range of ischaemic limbs, using two non-invasive techniques--laser Doppler (LD) and transcutaneous oximetry (TcPO2). Warmed TcPO2 and LD probes were placed over the first metatarsal cleft and SBF recorded with the limb horizontal, dependant and elevated. Ankle to brachial pressure ratios (A:B) were also measured. Twelve patients with lower limb ischaemia, mean A:B ratio 0.5 +/- 0.21 (+/- S.D.) were compared with 21 asymptomatic controls, mean A:B ratio 1.2 +/- 0.15. In the controls, neither TcPO2 nor LD values changed significantly with limb position. Both flux and oxygen tension were significantly lower in ischaemic limbs in all positions; on lowering the ischaemic limb, flux unexpectedly rose to 23.5 +/- 17.7 V from a mean of 14 + 9.0 V (horizontal). Both TcPO2 and LD correlated well with A:B ratio in two positions: horizontal r (TcPO2) = 0.73, r(LD) = 0.57; elevated r(TcPO2) = 0.78, r(LD) = 0.68. Overall there was a highly significant correlation between LD and TcPO2 (r = 0.6, P less than 0.001, Student's test), but this was strongest in the elevated position (r = 0.87, P less than 0.001). LD and TcPO2 relate to A:B ratio and to each other, particularly in the stressed limb; in the well perfused limb, the poorer correlation suggests skin perfusion is not linearly related to tissue oxygen tension.
Garadah, Taysir; Kassab, Salah; Gabani, Saleh; Abu-Taleb, Ahmed; Abdelatif, Ahmed; Asef, Aysha; Shoroqi, Issa; Jamsheer, Anwer
2011-01-01
Background Hypertensive crisis (HC) is a common medical emergency associated with acute rise in arterial blood pressure that leads to end-organ damage (EOD). Therefore, it is imperative to find markers that may help in the prediction of EOD in acute hypertensive crisis. Aim To assess the clinical presentations on admission; echocardiographic changes of pulsed and tissue Doppler changes in EOD patients compared with no EOD; and the risk of developing end organ damage for clinical and biochemical variables in hypertension crisis. Material and Methods The data of 241 patients with hypertensive crisis with systolic blood pressure (SBP) of >180 mmHg or diastolic blood pressure (DBP) >120 mmHg were extracted from patients files. Patients divided into hypertensive emergency (HE) with EOD, n = 62 and hypertensive urgency (HU) without EOD, n = 179. LV hypertrophy on ECG, echo parameters for wall thickness, left Ventricular mass index (LVMI), Body mass index (BMI), pulse Doppler ratio of early filling velocity E wave to late A wave (E/A) and ratio of E wave velocity to tissue Doppler Em to E wave (E/Em) were evaluated. Serum creatinine, hemoglobin, age, gender, body mass Index (BMI), history of diabetes mellitus, smoking, hypertension, stroke and hyperlipidemia were recorded. Multiple logistic regression analysis was applied for risk prediction of end organ damage of clinical variables. Results Patients with HE compared with HU were significantly older, with a significantly higher SBP on admission, high BMI and LVMI. Further there were significantly higher E/A ratio on Doppler echo and higher E/Em ratio on tissue Doppler echocardiogram. Multiple regression analysis with adjustment for age and sex shows positive predictive value with odds ratio of SBP on admission >220 mmHg of 1.98, serum creatinine > 120 µg/L of 1.43, older age > 60 year of 1.304, obesity (BMI ≥ 30) of 1.9, male gender of 2.26 and left ventricle hypertrophy on ECG of 1.92. The hemoglobin level, history of
Garadah, Taysir; Kassab, Salah; Gabani, Saleh; Abu-Taleb, Ahmed; Abdelatif, Ahmed; Asef, Aysha; Shoroqi, Issa; Jamsheer, Anwer
2011-01-01
Hypertensive crisis (HC) is a common medical emergency associated with acute rise in arterial blood pressure that leads to end-organ damage (EOD). Therefore, it is imperative to find markers that may help in the prediction of EOD in acute hypertensive crisis. To assess the clinical presentations on admission; echocardiographic changes of pulsed and tissue Doppler changes in EOD patients compared with no EOD; and the risk of developing end organ damage for clinical and biochemical variables in hypertension crisis. The data of 241 patients with hypertensive crisis with systolic blood pressure (SBP) of >180 mmHg or diastolic blood pressure (DBP) >120 mmHg were extracted from patients files. Patients divided into hypertensive emergency (HE) with EOD, n = 62 and hypertensive urgency (HU) without EOD, n = 179. LV hypertrophy on ECG, echo parameters for wall thickness, left Ventricular mass index (LVMI), Body mass index (BMI), pulse Doppler ratio of early filling velocity E wave to late A wave (E/A) and ratio of E wave velocity to tissue Doppler Em to E wave (E/Em) were evaluated. Serum creatinine, hemoglobin, age, gender, body mass Index (BMI), history of diabetes mellitus, smoking, hypertension, stroke and hyperlipidemia were recorded. Multiple logistic regression analysis was applied for risk prediction of end organ damage of clinical variables. Patients with HE compared with HU were significantly older, with a significantly higher SBP on admission, high BMI and LVMI. Further there were significantly higher E/A ratio on Doppler echo and higher E/Em ratio on tissue Doppler echocardiogram. Multiple regression analysis with adjustment for age and sex shows positive predictive value with odds ratio of SBP on admission >220 mmHg of 1.98, serum creatinine > 120 µg/L of 1.43, older age > 60 year of 1.304, obesity (BMI ≥ 30) of 1.9, male gender of 2.26 and left ventricle hypertrophy on ECG of 1.92. The hemoglobin level, history of smoking, hyperlipidemia and DM were with no
Cerebral Lateralization and General Intelligence: Gender Differences in a Transcranial Doppler Study
ERIC Educational Resources Information Center
Njemanze, P.C.
2005-01-01
The present study evaluated cerebral lateralization during Raven's progressive matrices (RPM) paradigm in female and male subjects. Bilateral simultaneous transcranial Doppler (TCD) ultrasound was used to measure mean blood flow velocities (MBFV) in the right and left middle cerebral arteries (MCAs) in 24 (15 females and 9 males) right-handed…
Brazilian Guidelines for transcranial doppler in children and adolescents with sickle cell disease
Lobo, Clarisse Lopes de Castro; Cançado, Rodolfo Delfini; Leite, Ana Claudia Celestino Bezerra; dos Anjos, Ana Claudia Mendonça; Pinto, Ana Cristina Silva; Matta, Andre Palma da Cunha; Silva, Célia Maria; Silva, Gisele Sampaio; Friedrisch, João Ricardo; Braga, Josefina Aparecida Pellegrini; Lange, Marcos Christiano; Figueiredo, Maria Stella; Rugani, Marília Álvares; Veloso, Orlando; Moura, Patrícia Gomes; Cortez, Paulo Ivo; Adams, Robert; Gualandro, Sandra Fátima Menosi; de Castilho, Shirley Lopes; Thomé, Ursula; Zetola, Viviane Flumignan
2011-01-01
Background Sickle cell disease is the most common monogenic hereditary disease in Brazil. Although strokes are one of the main causes of morbidity and mortality in these patients, the use of transcranial Doppler to identify children at risk is not universally used. Objective To develop Brazilian guidelines for the use of transcranial Doppler in sickle cell disease children and adolescents, so that related health policies can be expanded, and thus contribute to reduce morbidity and mortality. Methods The guidelines were formulated in a consensus meeting of experts in transcranial Doppler and sickle cell disease. The issues discussed were previously formulated and scientific articles in databases (MEDLINE, SciELO and Cochrane) were carefully analyzed. The consensus for each question was obtained by a vote of experts on the specific theme. Results Recommendations were made, including indications for the use of transcranial Doppler according to the sickle cell disease genotype and patients age; the necessary conditions to perform the exam and its periodicity depending on exam results; the criteria for the indication of blood transfusions and iron chelation therapy; the indication of hydroxyurea; and the therapeutic approach in cases of conditional transcranial Doppler. Conclusion The Brazilian guidelines on the use of transcranial doppler in sickle cell disease patients may reduce the risk of strokes, and thus reduce the morbidity and mortality and improve the quality of life of sickle cell disease patients. PMID:23284243
Reif, Roberto; Qin, Jia; Shi, Lei; Dziennis, Suzan; Zhi, Zhongwei; Nuttall, Alfred L; Wang, Ruikang K
2012-01-01
A synchronized dual-wavelength laser speckle contrast imaging (DWLSCI) system and a Doppler optical microangiography (DOMAG) system was developed to determine several ischemic parameters in the cochlea due to a systemic hypoxic challenge. DWLSCI can obtain two-dimensional data, and was used to determine the relative changes in cochlear blood flow, and change in the concentrations of oxyhemoglobin (HbO), deoxyhemoglobin (Hb) and total hemoglobin (HbT) in mice. DOMAG can obtain three-dimensional data, and was used to determine the changes in cochlear blood flow with single vessel resolution. It was demonstrated that during a hypoxic challenge there was an increase in the concentrations of Hb, a decrease in the concentrations of HbO and cochlear blood flow, and a slight decrease in the concentration of HbT. Also, the rate of change in the concentrations of Hb and HbO was quantified during and after the hypoxic challenge. The ability to simultaneously measure these ischemic parameters with high spatio-temporal resolution will allow the detailed quantitative analysis of several hearing disorders, and will be useful for diagnosing and developing treatments.
The resting-state fMRI arterial signal predicts differential blood transit time through the brain.
Tong, Yunjie; Yao, Jinxia Fiona; Chen, J Jean; Frederick, Blaise deB
2018-01-01
Previous studies have found that aperiodic, systemic low-frequency oscillations (sLFOs) are present in blood-oxygen-level-dependent (BOLD) data. These signals are in the same low frequency band as the "resting state" signal; however, they are distinct signals which represent non-neuronal, physiological oscillations. The same sLFOs are found in the periphery (i.e. finger tips) as changes in oxy/deoxy-hemoglobin concentration using concurrent near-infrared spectroscopy. Together, this evidence points toward an extra-cerebral origin of these sLFOs. If this is the case, it is expected that these sLFO signals would be found in the carotid arteries with time delays that precede the signals found in the brain. To test this hypothesis, we employed the publicly available MyConnectome dataset (a two-year longitudinal study of a single subject) to extract the sLFOs in the internal carotid arteries (ICAs) with the help of the T1/T2-weighted images. Significant, but negative, correlations were found between the LFO BOLD signals from the ICAs and (1) the global signal (GS), (2) the superior sagittal sinus, and (3) the jugulars. We found the consistent time delays between the sLFO signals from ICAs, GS and veins which coincide with the blood transit time through the cerebral vascular tree.
ICA-based artefact and accelerated fMRI acquisition for improved Resting State Network imaging
Griffanti, Ludovica; Salimi-Khorshidi, Gholamreza; Beckmann, Christian F.; Auerbach, Edward J.; Douaud, Gwenaëlle; Sexton, Claire E.; Zsoldos, Enikő; Ebmeier, Klaus P; Filippini, Nicola; Mackay, Clare E.; Moeller, Steen; Xu, Junqian; Yacoub, Essa; Baselli, Giuseppe; Ugurbil, Kamil; Miller, Karla L.; Smith, Stephen M.
2014-01-01
The identification of resting state networks (RSNs) and the quantification of their functional connectivity in resting-state fMRI (rfMRI) are seriously hindered by the presence of artefacts, many of which overlap spatially or spectrally with RSNs. Moreover, recent developments in fMRI acquisition yield data with higher spatial and temporal resolutions, but may increase artefacts both spatially and/or temporally. Hence the correct identification and removal of non-neural fluctuations is crucial, especially in accelerated acquisitions. In this paper we investigate the effectiveness of three data-driven cleaning procedures, compare standard against higher (spatial and temporal) resolution accelerated fMRI acquisitions, and investigate the combined effect of different acquisitions and different cleanup approaches. We applied single-subject independent component analysis (ICA), followed by automatic component classification with FMRIB’s ICA-based X-noiseifier (FIX) to identify artefactual components. We then compared two first-level (within-subject) cleaning approaches for removing those artefacts and motion-related fluctuations from the data. The effectiveness of the cleaning procedures were assessed using timeseries (amplitude and spectra), network matrix and spatial map analyses. For timeseries and network analyses we also tested the effect of a second-level cleaning (informed by group-level analysis). Comparing these approaches, the preferable balance between noise removal and signal loss was achieved by regressing out of the data the full space of motion-related fluctuations and only the unique variance of the artefactual ICA components. Using similar analyses, we also investigated the effects of different cleaning approaches on data from different acquisition sequences. With the optimal cleaning procedures, functional connectivity results from accelerated data were statistically comparable or significantly better than the standard (unaccelerated) acquisition
Color Doppler imaging of the retrobulbar vessels in diabetic retinopathy.
Pauk-Domańska, Magdalena; Walasik-Szemplińska, Dorota
2014-03-01
Diabetes is a metabolic disease characterized by elevated blood glucose level due to impaired insulin secretion and activity. Chronic hyperglycemia leads to functional disorders of numerous organs and to their damage. Vascular lesions belong to the most common late complications of diabetes. Microangiopathic lesions can be found in the eyeball, kidneys and nervous system. Macroangiopathy is associated with coronary and peripheral vessels. Diabetic retinopathy is the most common microangiopathic complication characterized by closure of slight retinal blood vessels and their permeability. Despite intensive research, the pathomechanism that leads to the development and progression of diabetic retinopathy is not fully understood. The examinations used in assessing diabetic retinopathy usually involve imaging of the vessels in the eyeball and the retina. Therefore, the examinations include: fluorescein angiography, optical coherence tomography of the retina, B-mode ultrasound imaging, perimetry and digital retinal photography. There are many papers that discuss the correlations between retrobulbar circulation alterations and progression of diabetic retinopathy based on Doppler sonography. Color Doppler imaging is a non-invasive method enabling measurements of blood flow velocities in small vessels of the eyeball. The most frequently assessed vessels include: the ophthalmic artery, which is the first branch of the internal carotid artery, as well as the central retinal vein and artery, and the posterior ciliary arteries. The analysis of hemodynamic alterations in the retrobulbar vessels may deliver important information concerning circulation in diabetes and help to answer the question whether there is a relation between the progression of diabetic retinopathy and the changes observed in blood flow in the vessels of the eyeball. This paper presents the overview of literature regarding studies on blood flow in the vessels of the eyeball in patients with diabetic
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
2011-01-01
Background Artifacts contained in EEG recordings hamper both, the visual interpretation by experts as well as the algorithmic processing and analysis (e.g. for Brain-Computer Interfaces (BCI) or for Mental State Monitoring). While hand-optimized selection of source components derived from Independent Component Analysis (ICA) to clean EEG data is widespread, the field could greatly profit from automated solutions based on Machine Learning methods. Existing ICA-based removal strategies depend on explicit recordings of an individual's artifacts or have not been shown to reliably identify muscle artifacts. Methods We propose an automatic method for the classification of general artifactual source components. They are estimated by TDSEP, an ICA method that takes temporal correlations into account. The linear classifier is based on an optimized feature subset determined by a Linear Programming Machine (LPM). The subset is composed of features from the frequency-, the spatial- and temporal domain. A subject independent classifier was trained on 640 TDSEP components (reaction time (RT) study, n = 12) that were hand labeled by experts as artifactual or brain sources and tested on 1080 new components of RT data of the same study. Generalization was tested on new data from two studies (auditory Event Related Potential (ERP) paradigm, n = 18; motor imagery BCI paradigm, n = 80) that used data with different channel setups and from new subjects. Results Based on six features only, the optimized linear classifier performed on level with the inter-expert disagreement (<10% Mean Squared Error (MSE)) on the RT data. On data of the auditory ERP study, the same pre-calculated classifier generalized well and achieved 15% MSE. On data of the motor imagery paradigm, we demonstrate that the discriminant information used for BCI is preserved when removing up to 60% of the most artifactual source components. Conclusions We propose a universal and efficient classifier of ICA components for
Automatic classification of artifactual ICA-components for artifact removal in EEG signals.
Winkler, Irene; Haufe, Stefan; Tangermann, Michael
2011-08-02
Artifacts contained in EEG recordings hamper both, the visual interpretation by experts as well as the algorithmic processing and analysis (e.g. for Brain-Computer Interfaces (BCI) or for Mental State Monitoring). While hand-optimized selection of source components derived from Independent Component Analysis (ICA) to clean EEG data is widespread, the field could greatly profit from automated solutions based on Machine Learning methods. Existing ICA-based removal strategies depend on explicit recordings of an individual's artifacts or have not been shown to reliably identify muscle artifacts. We propose an automatic method for the classification of general artifactual source components. They are estimated by TDSEP, an ICA method that takes temporal correlations into account. The linear classifier is based on an optimized feature subset determined by a Linear Programming Machine (LPM). The subset is composed of features from the frequency-, the spatial- and temporal domain. A subject independent classifier was trained on 640 TDSEP components (reaction time (RT) study, n = 12) that were hand labeled by experts as artifactual or brain sources and tested on 1080 new components of RT data of the same study. Generalization was tested on new data from two studies (auditory Event Related Potential (ERP) paradigm, n = 18; motor imagery BCI paradigm, n = 80) that used data with different channel setups and from new subjects. Based on six features only, the optimized linear classifier performed on level with the inter-expert disagreement (<10% Mean Squared Error (MSE)) on the RT data. On data of the auditory ERP study, the same pre-calculated classifier generalized well and achieved 15% MSE. On data of the motor imagery paradigm, we demonstrate that the discriminant information used for BCI is preserved when removing up to 60% of the most artifactual source components. We propose a universal and efficient classifier of ICA components for the subject independent removal of
ERIC Educational Resources Information Center
Kozoil, Micah E.
1989-01-01
Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…
Sun, Tong; Xu, Wen-Li; Hu, Tian; Liu, Mu-Hua
2013-12-01
The objective of the present research was to assess soluble solids content (SSC) of Nanfeng mandarin by visible/near infrared (Vis/NIR) spectroscopy combined with new variable selection method, simplify prediction model and improve the performance of prediction model for SSC of Nanfeng mandarin. A total of 300 Nanfeng mandarin samples were used, the numbers of Nanfeng mandarin samples in calibration, validation and prediction sets were 150, 75 and 75, respectively. Vis/NIR spectra of Nanfeng mandarin samples were acquired by a QualitySpec spectrometer in the wavelength range of 350-1000 nm. Uninformative variables elimination (UVE) was used to eliminate wavelength variables that had few information of SSC, then independent component analysis (ICA) was used to extract independent components (ICs) from spectra that eliminated uninformative wavelength variables. At last, least squares support vector machine (LS-SVM) was used to develop calibration models for SSC of Nanfeng mandarin using extracted ICs, and 75 prediction samples that had not been used for model development were used to evaluate the performance of SSC model of Nanfeng mandarin. The results indicate t hat Vis/NIR spectroscopy combinedwith UVE-ICA-LS-SVM is suitable for assessing SSC o f Nanfeng mandarin, and t he precision o f prediction ishigh. UVE--ICA is an effective method to eliminate uninformative wavelength variables, extract important spectral information, simplify prediction model and improve the performance of prediction model. The SSC model developed by UVE-ICA-LS-SVM is superior to that developed by PLS, PCA-LS-SVM or ICA-LS-SVM, and the coefficient of determination and root mean square error in calibration, validation and prediction sets were 0.978, 0.230%, 0.965, 0.301% and 0.967, 0.292%, respectively.
Kuznetsova, Tatiana; Cauwenberghs, Nicholas; Knez, Judita; Thijs, Lutgarde; Liu, Yan-Ping; Gu, Yu-Mei; Staessen, Jan A
2015-04-01
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited information is available regarding the relationship between RRI and cardiac hemodynamics. We investigated these associations in randomly recruited subjects from a general population. In 171 participants (48.5% women; mean age, 52.2 years), using pulsed wave Doppler, we measured RRI (mean, 0.60) and left ventricular outflow tract (LVOT) and transmitral (E and A) blood flow peak velocities and its velocity time integrals (VTI). Using carotid applanation tonometry, we measured central pulse pressure and arterial stiffness indexes such as augmentation pressure and carotid-femoral pulse wave velocity. In stepwise regression analysis, RRI independently and significantly increased with female sex, age, body weight, brachial pulse pressure, and use of β-blockers, whereas it decreased with body height and mean arterial pressure. In multivariable-adjusted models with central pulse pressure and arterial stiffness indexes as the explanatory variables, we observed a significant and positive correlation of RRI only with central pulse pressure (P < 0.0001). Among the Doppler indexes of left ventricular blood flow, RRI was significantly and positively associated with LVOT and E peak velocities (P ≤ 0.012) and VTIs (P ≤ 0.010). We demonstrated that in unselected subjects RRI was significantly associated with central pulse pressure and left ventricular systolic and diastolic Doppler blood flow indexes. Our findings imply that in addition to the anthropometric characteristics, cardiac hemodynamic factors influence the intrarenal arterial Doppler waveform patterns. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email
Adali, Tülay; Levin-Schwartz, Yuri; Calhoun, Vince D.
2015-01-01
Fusion of information from multiple sets of data in order to extract a set of features that are most useful and relevant for the given task is inherent to many problems we deal with today. Since, usually, very little is known about the actual interaction among the datasets, it is highly desirable to minimize the underlying assumptions. This has been the main reason for the growing importance of data-driven methods, and in particular of independent component analysis (ICA) as it provides useful decompositions with a simple generative model and using only the assumption of statistical independence. A recent extension of ICA, independent vector analysis (IVA) generalizes ICA to multiple datasets by exploiting the statistical dependence across the datasets, and hence, as we discuss in this paper, provides an attractive solution to fusion of data from multiple datasets along with ICA. In this paper, we focus on two multivariate solutions for multi-modal data fusion that let multiple modalities fully interact for the estimation of underlying features that jointly report on all modalities. One solution is the Joint ICA model that has found wide application in medical imaging, and the second one is the the Transposed IVA model introduced here as a generalization of an approach based on multi-set canonical correlation analysis. In the discussion, we emphasize the role of diversity in the decompositions achieved by these two models, present their properties and implementation details to enable the user make informed decisions on the selection of a model along with its associated parameters. Discussions are supported by simulation results to help highlight the main issues in the implementation of these methods. PMID:26525830
Doppler flowmetry in preeclampsia.
Zahumensky, J
2009-01-01
The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.
Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam
2017-05-01
Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Evaluation of meteorological airborne Doppler radar
NASA Technical Reports Server (NTRS)
Hildebrand, P. H.; Mueller, C. K.
1984-01-01
This paper will discuss the capabilities of airborne Doppler radar for atmospheric sciences research. The evaluation is based on airborne and ground based Doppler radar observations of convective storms. The capability of airborne Doppler radar to measure horizontal and vertical air motions is evaluated. Airborne Doppler radar is shown to be a viable tool for atmospheric sciences research.
Laser Doppler pulp vitality measurements: simulation and measurement
NASA Astrophysics Data System (ADS)
Ertl, T.
2017-02-01
Frequently pulp vitality measurement is done in a dental practice by pressing a frozen cotton pellet on the tooth. This method is subjective, as the patient's response is required, sometimes painful and has moderate sensitivity and specificity. Other methods, based on optical or electrical measurement have been published, but didńt find wide spread application in the dental offices. Laser Doppler measurement of the blood flow in the pulp could be an objective method to measure pulp vitality, but the influence of the gingival blood flow on the measurements is a concern. Therefore experiments and simulations were done to learn more about the gingival blood flow in relation to the pulpal blood flow and how to minimize the influence. First patient measurements were done to show the feasibility clinically. Results: Monte Carlo simulations and bench experiments simulating the blood flow in and around a tooth show that both basic configurations, transmission and reflection measurements are possible. Most favorable is a multi-point measurement with different distances from the gingiva. Preliminary sensitivity / specificity are promising and might allow an objective and painless measurement of tooth vitality.
Finnish Meteorological Institute Doppler Lidar
Ewan OConnor
2015-03-27
This doppler lidar system provides co-polar and cross polar attenuated backscatter coefficients,signal strength, and doppler velocities in the cloud and in the boundary level, including uncertainties for all parameters. Using the doppler beam swinging DBS technique, and Vertical Azimuthal Display (VAD) this system also provides vertical profiles of horizontal winds.
Petlevich, Walter J.; Sverdrup, Edward F.
1978-01-01
A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.
Color Doppler imaging of retinal diseases.
Dimitrova, Galina; Kato, Satoshi
2010-01-01
Color Doppler imaging (CDI) is a widely used method for evaluating ocular circulation that has been used in a number of studies on retinal diseases. CDI assesses blood velocity parameters by using ultrasound waves. In ophthalmology, these assessments are mainly performed on the retrobulbar blood vessels: the ophthalmic, the central retinal, and the short posterior ciliary arteries. In this review, we discuss CDI use for the assessment of retinal diseases classified into the following: vascular diseases, degenerations, dystrophies, and detachment. The retinal vascular diseases that have been investigated by CDI include diabetic retinopathy, retinal vein occlusions, retinal artery occlusions, ocular ischemic conditions, and retinopathy of prematurity. Degenerations and dystrophies included in this review are age-related macular degeneration, myopia, and retinitis pigmentosa. CDI has been used for the differential diagnosis of retinal detachment, as well as the evaluation of retrobulbar circulation in this condition. CDI is valuable for research and is a potentially useful diagnostic tool in the clinical setting.
Computerized Doppler Tomography and Spectrum Analysis of Carotid Artery Flow
Morton, Paul; Goldman, Dave; Nichols, W. Kirt
1981-01-01
Contrast angiography remains the definitive study in the evaluation of atherosclerotic occlusive vascular disease. However, a safer technique for serial screening of symptomatic patients and for routine follow up is necessary. Computerized pulsed Doppler ultrasonic arteriography is a noninvasive technique developed by Miles6 for imaging lateral, antero-posterior and transverse sections of the carotid artery. We [ill] this system with new software and hardware to analyze the three-dimensional blood flow data. The system now provides information about the location of the occlusive process in the artery and a semi-quantitative evaluation of the degree of obstruction. In addition, we interfaced a digital signal analyzer to the system which permits spectrum analysis of the pulsed Doppler signal. This addition has allowed us to identify lesions which are not yet hemodynamically significant. ImagesFig. 2bFig. 2c
Doppler-corrected differential detection system
NASA Technical Reports Server (NTRS)
Simon, Marvin K. (Inventor); Divsalar, Dariush (Inventor)
1991-01-01
Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.
Toward the development of a low-cost laser Doppler module for ophthalmic microscopes
NASA Astrophysics Data System (ADS)
Cattini, Stefano; Rovati, Luigi
2012-03-01
A laser Doppler module easily integrated into a commercial ophthalmic microscope is proposed. Such setup adds flow measurement capability to standard visual inspection of the fundus. The proposed instrument may provide important clinical information such as the detection of vessel occlusion provided by surgical treatments (i.e. photocoagulation). The measuring system is based on a self-mixing laser diode Doppler flowmeter (SM-DF). Reduced costs, easy implementation and small size represent the main features of SM-DF. Moreover, this technique offers the advantage to have the excitation and measurement beams spatially overlapped, thus both overcoming the alignment difficulty of traditional laser Doppler flowmeter and, well fitting with to limited optical aperture of the pupil. Thanks to an on-board DSP-microcontroller, the optoelectronic module directly estimates the blood flow; USB connection and an ad-hoc developed user-friendly software interface allow displaying the result on a personal computer. Preliminary test demonstrates the applicability of the proposed measuring system.
Gorcsan, J; Snow, F R; Paulsen, W; Nixon, J V
1991-03-01
A completely noninvasive method for estimating left atrial pressure in patients with congestive heart failure and mitral regurgitation has been devised with the use of continuous-wave Doppler echocardiography and brachial sphygmomanometry. Of 46 patients studied with mitral regurgitation, 35 (76%) had jets with distinct Doppler spectral envelopes recorded. The peak ventriculoatrial gradient was obtained by measuring peak mitral regurgitant velocity in systole and using the modified Bernoulli equation. This gradient was then subtracted from peak brachial systolic blood pressure, an estimate of left ventricular systolic pressure, to yield left atrial pressure (left atrial pressure = systolic blood pressure - mitral regurgitant pressure gradient). Noninvasive estimates of left atrial pressure from 35 patients were plotted against simultaneous recordings of mean pulmonary capillary wedge pressure resulting in the correlation y = 0.88x + 3.3, r = 0.88, standard error of estimate = +/- 4 mm Hg (p less than 0.001). Therefore, continuous-wave Doppler echocardiography and sphygmomanometry may be used in selected patients with congestive heart failure and mitral regurgitation for noninvasive estimation of left atrial pressure.
Brothers, R. Matthew; Wingo, Jonathan E.; Hubing, Kimberly A.
2010-01-01
Skin blood flow responses in the human forearm, assessed by three commonly used technologies—single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging—were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature = 1.0 ± 0.2°C; P < 0.001). In addition, while normothermic and heat stressed, subjects were exposed to 30-mmHg lower-body negative pressure (LBNP). Skin blood flow was normalized to the maximum value obtained at each site during local heating to 42°C for at least 30 min. Furthermore, comparisons of forearm blood flow (FBF) measures obtained using venous occlusion plethysmography and Doppler ultrasound were made during the aforementioned perturbations. Relative to normothermic baseline, skin blood flow decreased during normothermia + LBNP (P < 0.05) and skin-surface cooling (P < 0.01) and increased during whole body heating (P < 0.001). Subsequent LBNP during whole body heating significantly decreased skin blood flow relative to control heat stress (P < 0.05). Importantly, for each of the aforementioned conditions, skin blood flow was similar between the three measurement devices (main effect of device: P > 0.05 for all conditions). Similarly, no differences were identified across all perturbations between FBF measures using plethysmography and Doppler ultrasound (P > 0.05 for all perturbations). These data indicate that when normalized to maximum, assessment of skin blood flow in response to vasoconstrictor and dilator perturbations are similar regardless of methodology. Likewise, FBF responses to these perturbations are similar between two commonly used methodologies of limb blood flow assessment. PMID:20634360
Brothers, R Matthew; Wingo, Jonathan E; Hubing, Kimberly A; Crandall, Craig G
2010-09-01
Skin blood flow responses in the human forearm, assessed by three commonly used technologies-single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging-were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature=1.0±0.2 degrees C; P<0.001). In addition, while normothermic and heat stressed, subjects were exposed to 30-mmHg lower-body negative pressure (LBNP). Skin blood flow was normalized to the maximum value obtained at each site during local heating to 42 degrees C for at least 30 min. Furthermore, comparisons of forearm blood flow (FBF) measures obtained using venous occlusion plethysmography and Doppler ultrasound were made during the aforementioned perturbations. Relative to normothermic baseline, skin blood flow decreased during normothermia+LBNP (P<0.05) and skin-surface cooling (P<0.01) and increased during whole body heating (P<0.001). Subsequent LBNP during whole body heating significantly decreased skin blood flow relative to control heat stress (P<0.05). Importantly, for each of the aforementioned conditions, skin blood flow was similar between the three measurement devices (main effect of device: P>0.05 for all conditions). Similarly, no differences were identified across all perturbations between FBF measures using plethysmography and Doppler ultrasound (P>0.05 for all perturbations). These data indicate that when normalized to maximum, assessment of skin blood flow in response to vasoconstrictor and dilator perturbations are similar regardless of methodology. Likewise, FBF responses to these perturbations are similar between two commonly used methodologies of limb blood flow assessment.
Kasteleijn-Nolst Trenité, Dorotheé G A; Biton, Victor; French, Jacqueline A; Abou-Khalil, Bassel; Rosenfeld, William E; Diventura, Bree; Moore, Elizabeth L; Hetherington, Seth V; Rigdon, Greg C
2013-08-01
To assess the effects of ICA-105665, an agonist of neuronal Kv7 potassium channels, on epileptiform EEG discharges, evoked by intermittent photic stimulation (IPS), the so-called photoparoxysmal responses (PPRs) in patients with epilepsy. Male and female patients aged 18-60 years with reproducible PPRs were eligible for enrollment. The study was conducted as a single-blind, single-dose, multiple-cohort study. Four patients were enrolled in each of the first three cohorts. Six patients were enrolled in the fourth cohort and one patient was enrolled in the fifth cohort. PPR responses to 14 IPS frequencies (steps) were used to determine the standard photosensitivity range (SPR) following placebo on day 1 and ICA-105665 on day 2. The SPR was quantified for three eye conditions (eyes closing, eyes closed, and eyes open), and the most sensitive condition was used for assessment of efficacy. A partial response was defined as a reduction in the SPR of at least three units at three separate time points following ICA-105665 compared to the same time points following placebo with no time points with more than three units of increase. Complete suppression was defined by no PPRs in any eye condition at one or more time points. Six individual patients participated in the first three cohorts (100, 200, and 400 mg). Six patients participated in the fourth cohort (500 mg), and one patient participated in the fifth cohort (600 mg). Decreases in SPR occurred in one patient at 100 mg, two patients receiving 400 mg ICA-105665 (complete abolishment of SPR occurred in one patient at 400 mg), and in four of six patients receiving 500 mg. The most common adverse events (AEs) were those related to the nervous system, and dizziness appeared to be the first emerging AE. The single patient in the 600 mg cohort developed a brief generalized seizure within 1 h of dosing, leading to the discontinuation of additional patients at this dose, per the predefined protocol stopping rules. ICA-105665
[Effect of hemorheology on ultrasonic doppler blood flow spectrum diagram].
Zhang, Shenghua; Qin, Renjia
2014-08-01
The present research aims to point out the long-existing defect of analyzing the spectrum diagram only from the perspective of haemodynamics instead of haemorheology. In the light of the theories of haemodynamics and haemorheology, the causes of spectrum diagram formation of carotid artery blood at the rapid and slow flow can be clarified completely and accurately. Four conclusions have been drawn in the end. As long as the velocity gradient is large enough, obvious red blood cells concentrate to the shaft even in the big or bigger blood vessels; the spectrum diagram is the powerful proof of the two phase flow model of blood; the spectrum diagram can be completely and accurately analyzed only by combining haemodynamics with haemorheology; and only when the red blood cells concentrate to the shaft, the big or bigger blood vessels can be regarded as haemogeneous fluid.
Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo
2017-03-01
Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.
Real-time and interactive virtual Doppler ultrasound
NASA Astrophysics Data System (ADS)
Hirji, Samira; Downey, Donal B.; Holdsworth, David W.; Steinman, David A.
2005-04-01
This paper describes our "virtual" Doppler ultrasound (DUS) system, in which colour DUS (CDUS) images and DUS spectrograms are generated on-the-fly and displayed in real-time in response to position and orientation cues provided by a magnetically tracked handheld probe. As the presence of complex flow often confounds the interpretation of Doppler ultrasound data, this system will serve to be a fundamental tool for training sonographers and gaining insight into the relationship between ambiguous DUS images and complex blood flow dynamics. Recently, we demonstrated that DUS spectra could be realistically simulated in real-time, by coupling a semi-empirical model of the DUS physics to a 3-D computational fluid dynamics (CFD) model of a clinically relevant flow field. Our system is an evolution of this approach where a motion-tracking device is used to continuously update the origin and orientation of a slice passing through a CFD model of a stenosed carotid bifurcation. After calibrating our CFD model onto a physical representation of a human neck, virtual CDUS images from an instantaneous slice are then displayed at a rate of approximately 15 Hz by simulating, on-the-fly, an array of DUS spectra and colour coding the resulting spectral mean velocity using a traditional Doppler colour scale. Mimicking a clinical examination, the operator can freeze the CDUS image on-screen, and a spectrogram corresponding to the selected sample volume location is rendered at a higher frame rate of at least 30 Hz. All this is achieved using an inexpensive desktop workstation and commodity graphics card.
NASA Astrophysics Data System (ADS)
Berradja, Khadidja; Boughanmi, Nabil
2016-09-01
In dynamic cardiac PET FDG studies the assessment of myocardial metabolic rate of glucose (MMRG) requires the knowledge of the blood input function (IF). IF can be obtained by manual or automatic blood sampling and cross calibrated with PET. These procedures are cumbersome, invasive and generate uncertainties. The IF is contaminated by spillover of radioactivity from the adjacent myocardium and this could cause important error in the estimated MMRG. In this study, we show that the IF can be extracted from the images in a rat heart study with 18F-fluorodeoxyglucose (18F-FDG) by means of Independent Component Analysis (ICA) based on Bayesian theory and Markov Chain Monte Carlo (MCMC) sampling method (BICA). Images of the heart from rats were acquired with the Sherbrooke small animal PET scanner. A region of interest (ROI) was drawn around the rat image and decomposed into blood and tissue using BICA. The Statistical study showed that there is a significant difference (p < 0.05) between MMRG obtained with IF extracted by BICA with respect to IF extracted from measured images corrupted with spillover.
Laser Doppler Velocimetry Workshop
NASA Technical Reports Server (NTRS)
Owen, R. B.
1979-01-01
The potential of laser Doppler velocimetry as a technique for use in mapping flows in the several fluid systems under development for doing research on low-gravity processes, is investigated. Laser Doppler velocimetry techniques, equipment, and applications are summarized.
Funane, Tsukasa; Sato, Hiroki; Yahata, Noriaki; Takizawa, Ryu; Nishimura, Yukika; Kinoshita, Akihide; Katura, Takusige; Atsumori, Hirokazu; Fukuda, Masato; Kasai, Kiyoto; Koizumi, Hideaki; Kiguchi, Masashi
2015-01-01
Abstract. It has been reported that a functional near-infrared spectroscopy (fNIRS) signal can be contaminated by extracerebral contributions. Many algorithms using multidistance separations to address this issue have been proposed, but their spatial separation performance has rarely been validated with simultaneous measurements of fNIRS and functional magnetic resonance imaging (fMRI). We previously proposed a method for discriminating between deep and shallow contributions in fNIRS signals, referred to as the multidistance independent component analysis (MD-ICA) method. In this study, to validate the MD-ICA method from the spatial aspect, multidistance fNIRS, fMRI, and laser-Doppler-flowmetry signals were simultaneously obtained for 12 healthy adult males during three tasks. The fNIRS signal was separated into deep and shallow signals by using the MD-ICA method, and the correlation between the waveforms of the separated fNIRS signals and the gray matter blood oxygenation level–dependent signals was analyzed. A three-way analysis of variance (signal depth×Hb kind×task) indicated that the main effect of fNIRS signal depth on the correlation is significant [F(1,1286)=5.34, p<0.05]. This result indicates that the MD-ICA method successfully separates fNIRS signals into spatially deep and shallow signals, and the accuracy and reliability of the fNIRS signal will be improved with the method. PMID:26157983
Fontseré, Néstor; Mestres, Gaspar; Barrufet, Marta; Burrel, Marta; Vera, Manel; Arias, Marta; Masso, Elisabeth; Cases, Aleix; Maduell, Francisco; Campistol, Josep M
2013-01-01
The current clinical guidelines recommend indirect access blood flow (Qa) measurement as one of the most important components in vascular access maintenance programs. The best-know methods are doppler ultrasound (DU) and saline dilution method. This study evaluates the efficiency of Qa measurement with thermodilution method (TD) in comparison with the DU. Transversal study in 64 patients in hemodialysis (41 men); mean age 59.9 years with 54 AVFs and 10 PTFE. Qa reference value was obtained with DU in brachial artery (AVFs) or at the zone of arterial puncture (AVGs). Bland-Altman and interclass correlation coefficient (ICC) were used to study accuracy. Mean values obtained with DU-Qa were 1426 ± 753 mL/min AVFs and 1186 ± 789 mL/min AVGs. The mean Qa with TD was 1372 ± 770 AVFs (bias 54.6; ICC 0.923) and 1176 ± 758 AVGs (bias 10.2; ICC 0.992). In the subgroup of 28 patients with radiocephalic latero-terminal AVFs the DU-Qa was 1232 ± 767 mL/min. The Qa was in radial artery 942 (ICC 0.805); radial-ulnar artery 1103 (ICC 0.973); cephalic vein 788 (ICC 0.772) and TD 1026 (ICC 0.971). We detected 5 cases of significant stenosis. After endovascular treatment the Kt was 79 liters (61; p=0.043) and TD-Qa 895 mL/min (663; p=0.043). TD represents a good indirect method of Qa measurement. In the subgroup of patients with radiocephalic AVFs, Qa measurements in the radial and ulnar artery are more accurate. Therefore, in this situation the TD method obtained an excellent correlation in comparison to brachial artery.
Malinova, Vesna; von Eckardstein, Kajetan; Rohde, Veit; Mielke, Dorothee
2015-10-01
The intraoperative microvascular Doppler sonography (iMDS) is a well-established tool in vascular surgery for blood flow velocity (BFV) monitoring, capable of detecting vessel occlusion. However, identification of subtotal vessel compromise is more difficult, since the measured BFV may substantially vary with changing insonation angles and insonated vessel segments. To keep these parameters constant we combined neuronavigation with iMDS (niMDS). The question was if niMDS allows the detection of subtotal vessel compromise in aneurysm surgery. During surgery, the 3-dimensional reconstruction of the CT-angiography, which was obtained routinely prior to surgery, was displayed by the neuronavigational system. Prior to clipping, neuronavigation was used to define target point and trajectory, which, by coupling the neuronavigational pointer with the Doppler probe, correspond to the insonated vessel segment and the insonation angle. After clipping, for each vessel segment, the same trajectory was used for all consecutive measurements. The mean BFVs pre- and post-clipping were documented. We performed 82 BFV-measurements in 39 aneurysm surgeries. Mean deviation between pre- and post-clipping BFV values was 2.12cm/s. There was a significant correlation between the mean BFV values before and after clipping (r=0.45 [95% CI 17-66%]; p=0.002). One patient experienced new neurological deficits due to occlusion of a perforating vessel that was not insonated. The study could not answer the question if niMDS can detect BFV changes after clipping indicating vessel compromise, as no subtotal vessel occlusion occurred in the 39 operations. However, we proofed that niMDS-measured BFVs only varied minimally in uncompromised vessels pre- and post-clipping, suggesting that vessel compromises might be easily detected during aneurysm surgery. Copyright © 2015 Elsevier B.V. All rights reserved.
A new method for blood velocity measurements using ultrasound FMCW signals.
Kunita, Masanori; Sudo, Masamitsu; Inoue, Shinya; Akahane, Mutsuhiro
2010-05-01
The low peak power of frequency-modulated continuous wave (FMCW) radar makes it attractive for various applications, including vehicle collision warning systems and airborne radio altimeters. This paper describes a new ultrasound Doppler measurement system that measures blood flow velocity based on principles similar to those of FMCW radar. We propose a sinusoidal wave for FM modulation and introduce a new demodulation technique for obtaining Doppler information with high SNR and range resolution. Doppler signals are demodulated with a reference FMCW signal to adjust delay times so that they are equal to propagation times between the transmitter and the receiver. Analytical results suggest that Doppler signals can be obtained from a selected position, as with a sample volume in pulse wave Doppler systems, and that the resulting SNR is nearly identical to that obtained with continuous wave (CW) Doppler systems. Additionally, clutter power is less than that of CW Doppler systems. The analytical results were verified by experiments involving electronic circuits and Doppler ultrasound phantoms.
Doppler color imaging. Principles and instrumentation.
Kremkau, F W
1992-01-01
DCI acquires Doppler-shifted echoes from a cross-section of tissue scanned by an ultrasound beam. These echoes are then presented in color and superimposed on the gray-scale anatomic image of non-Doppler-shifted echoes received during the scan. The flow echoes are assigned colors according to the color map chosen. Usually red, yellow, or white indicates positive Doppler shifts (approaching flow) and blue, cyan, or white indicates negative shifts (receding flow). Green is added to indicate variance (disturbed or turbulent flow). Several pulses (the number is called the ensemble length) are needed to generate a color scan line. Linear, convex, phased, and annular arrays are used to acquire the gray-scale and color-flow information. Doppler color-flow instruments are pulsed-Doppler instruments and are subject to the same limitations, such as Doppler angle dependence and aliasing, as other Doppler instruments. Color controls include gain, TGC, map selection, variance on/off, persistence, ensemble length, color/gray priority. Nyquist limit (PRF), baseline shift, wall filter, and color window angle, location, and size. Doppler color-flow instruments generally have output intensities intermediate between those of gray-scale imaging and pulsed-Doppler duplex instruments. Although there is no known risk with the use of color-flow instruments, prudent practice dictates that they be used for medical indications and with the minimum exposure time and instrument output required to obtain the needed diagnostic information.
Lappen, Justin R; Myers, Stephen A; Bolden, Norman; Shaman, Ziad; Angirekula, Venkata; Chien, Edward K
2018-03-01
Narrow pulse pressure has been demonstrated to indicate low central volume status. In critically ill patients, volume status can be qualitatively evaluated using Doppler velocimetry to assess hemodynamic changes in the carotid artery in response to autotransfusion with passive leg raise (PLR). Neither parameter has been prospectively evaluated in an obstetric population. The objective of this study was to determine if pulse pressure could predict the response to autotransfusion using carotid artery Doppler in healthy intrapartum women. We hypothesized that the carotid artery Doppler response to PLR would be greater in women with a narrow pulse pressure, indicating relative hypovolemia. Intrapartum women with singleton gestations ≥35 weeks without acute or chronic medical conditions were recruited to this prospective cohort study. Participants were grouped by admission pulse pressure as <45 mm Hg(narrow) or ≥50 mm Hg(normal). Maternal carotid artery Doppler assessment was then performed in all patients before and after PLR using a standard technique where carotid blood flow (mL/min) = π × (carotid artery diameter/2) × (velocity time integral) x (60 seconds). The velocity time integral was calculated from the Doppler waveform. The primary outcome was the change in the carotid Doppler parameters (carotid artery diameter, velocity time integral, and carotid blood flow) after PLR. Outcomes were compared between study groups with univariable and multivariable analyses with adjustment for potential confounding factors. Thirty-three women consented to participation, including 18 in the narrow and 15 in the normal pulse pressure groups (mean and standard deviation initial pulse pressure, 38.3 ± 4.4 vs 57.3 ± 4.1 mm Hg). The 2 groups demonstrated similar characteristics except for initial pulse pressure, systolic and diastolic blood pressure, and race. In response to PLR, the narrow pulse pressure group had a significantly greater increase in carotid artery diameter
Doppler ultrasound monitoring technology.
Docker, M F
1993-03-01
Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.
[Basic laws of blood screw motion in human common carotid arteries].
Kulikov, V P; Kirsanov, R I
2008-08-01
The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.
Drisdelle, Brandi Lee; Aubin, Sébrina; Jolicoeur, Pierre
2017-01-01
The objective of the present study was to assess the robustness and reliability of independent component analysis (ICA) as a method for ocular artifact correction in electrophysiological studies of visual-spatial attention and memory. The N2pc and sustained posterior contralateral negativity (SPCN), electrophysiological markers of visual-spatial attention and memory, respectively, are lateralized posterior ERPs typically observed following the presentation of lateral stimuli (targets and distractors) along with instructions to maintain fixation on the center of the visual search for the entire trial. Traditionally, trials in which subjects may have displaced their gaze are rejected based on a cutoff threshold, minimizing electrophysiological contamination by saccades. Given the loss of data resulting from rejection, we examined ocular correction by comparing results using standard fixation instructions against a condition where subjects were instructed to shift their gaze toward possible targets. Both conditions were analyzed using a rejection threshold and ICA correction for saccade activity management. Results demonstrate that ICA conserves data that would have otherwise been removed and leaves the underlying neural activity intact, as demonstrated by experimental manipulations previously shown to modulate the N2pc and the SPCN. Not only does ICA salvage and not distort data, but also large eye movements had only subtle effects. Overall, the findings provide convincing evidence for ICA correction for not only special cases (e.g., subjects did not follow fixation instruction) but also as a candidate for standard ocular artifact management in electrophysiological studies interested in visual-spatial attention and memory. © 2016 Society for Psychophysiological Research.
Donahue, Manus J; van Laar, Peter Jan; van Zijl, Peter C M; Stevens, Robert D; Hendrikse, Jeroen
2009-03-01
To assess the role of vascular space occupancy (VASO) magnetic resonance imaging (MRI), a noninvasive cerebral blood volume (CBV)-weighted technique, for evaluating CBV reactivity in patients with internal carotid artery (ICA) stenosis. VASO reactivity, defined as a signal change in response to hypercapnic stimulus (4-second exhale, 14-second breath-hold), was measured in the left and right ICA flow territories in patients (n=10) with varying degrees of unilateral and bilateral ICA stenosis and in healthy volunteers (n=10). Percent VASO reactivity was more negative (P<0.01) bilaterally in patients (ipsilateral: -3.6+/-1.5%; contralateral: -3.4+/-1.2%) compared with age-matched controls (left: -1.9+/-0.6%; right: -1.9+/-0.8%). Owing to the nature of the VASO contrast mechanism, this more negative VASO reactivity was attributed to autoregulatory CBV effects in patients. A postbreath-hold overshoot, which was absent in healthy volunteers, was observed unilaterally in a subset of patients. More negative VASO reactivity was observed in patients with ICA stenosis and may be a marker of autoregulatory effects. Furthermore, the postbreath-hold overshoot observed in patients is consistent with compensatory microvascular vasoconstriction and may be a marker of hemodynamic impairment. Based on the results of this feasibility study, VASO should be useful for identifying CBV adjustments in patients with steno-occlusive disease of the ICA. Copyright (c) 2009 Wiley-Liss, Inc.
Brueggemann, Lyubov I.; Haick, Jennifer M.; Cribbs, Leanne L.
2014-01-01
Recent research suggests that smooth muscle cells express Kv7.4 and Kv7.5 voltage-activated potassium channels, which contribute to maintenance of their resting membrane voltage. New pharmacologic activators of Kv7 channels, ML213 (N-mesitybicyclo[2.2.1]heptane-2-carboxamide) and ICA-069673 N-(6-chloropyridin-3-yl)-3,4-difluorobenzamide), have been reported to discriminate among channels formed from different Kv7 subtypes. We compared the effects of ML213 and ICA-069673 on homomeric human Kv7.4, Kv7.5, and heteromeric Kv7.4/7.5 channels exogenously expressed in A7r5 vascular smooth muscle cells. We found that, despite its previous description as a selective activator of Kv7.2 and Kv7.4, ML213 significantly increased the maximum conductance of homomeric Kv7.4 and Kv7.5, as well as heteromeric Kv7.4/7.5 channels, and induced a negative shift of their activation curves. Current deactivation rates decreased in the presence of the ML213 (10 μM) for all three channel combinations. Mutants of Kv7.4 (W242L) and Kv7.5 (W235L), previously found to be insensitive to another Kv7 channel activator, retigabine, were also insensitive to ML213 (10 μM). In contrast to ML213, ICA-069673 robustly activated Kv7.4 channels but was significantly less effective on homomeric Kv7.5 channels. Heteromeric Kv7.4/7.5 channels displayed intermediate responses to ICA-069673. In each case, ICA-069673 induced a negative shift of the activation curves without significantly increasing maximal conductance. Current deactivation rates decreased in the presence of ICA-069673 in a subunit-specific manner. Kv7.4 W242L responded to ICA-069673-like wild-type Kv7.4, but a Kv7.4 F143A mutant was much less sensitive to ICA-069673. Based on these results, ML213 and ICA-069673 likely bind to different sites and are differentially selective among Kv7.4, Kv7.5, and Kv7.4/7.5 channel subtypes. PMID:24944189
Diastolic blood pressure-estimated left ventricular dp/dt.
Yilmaz, Hüseyin; Minareci, Kenan; Kabukçu, Mehmet; Sancaktar, Oktay
2002-02-01
Peak dp/dt is one of the best isovolumic phase indexes of the myocardial contractile state requiring invasive procedures or presence of mitral regurgitation severe enough to measure in clinical practice by Doppler echocardiography. In this study, we sought the correlation between two noninvasive methods of measurements for left ventricular dp/dt-diastolic blood pressure- (DBP) estimated and continuous-wave Doppler-derived dp/dt-min electrocardiographic/echocardiographic study to emphasize the clinical feasibility of the DBP-estimated method. Thirty-six randomized patients (27 male, 9 female; 58 +/- 8 years) with mild mitral regurgitation were enrolled in this study. DBP-estimated dp/dt was calculated from DBP minus the left ventricular end-diastolic pressure (LVEDP) over the isovolumetric contraction time (IVCT). LVEDP was assumed to be 10 mmHg for all patients. Doppler-determined left ventricular dp/dt was derived from the continuous-wave Doppler spectrum of mitral regurgitation jet by dividing the magnitude of the left ventricular atrial pressure gradient rise between 1 mm/sec-3 mm/sec of mitral regurgitant velocity signal by the time taken for this change. Left ventricular dp/dt by Doppler was 1122 +/- 303 mmHg/sec and blood pressure-estimated dp/dt was 1063 +/- 294 mmHg/sec. There was a high correlation (r = 0.97, P < 0.001) of dp/dt between the two techniques. DBP and IVCT can generate left ventricular dp/dt without invasive procedures, even in the absence of mitral regurgitation in clinical practice.
Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren
2006-12-01
The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced
Evidence of stimulus correlated empathy modes--Group ICA of fMRI data.
Vemuri, Kavita; Surampudi, Bapi Raju
2015-03-01
The analysis of the cognitive processes in response to a narrative as presented in a movie provides an insight into momentary reaction to a single depicted action like a facial expression and an aggregate processing of the entire sequence of events. In this study we report results from fMRI data analyzed by group independent component analysis (ICA) method from a free viewing experiment using a diverse set of movie clips--an animation, a Hollywood and an Indian Hindi movie. The fMRI data were collected from 15 college students as they viewed 5-8 min clips from three movies. The movie clips were rated for depiction of emotional expressions, the emotion as per the narrative and the viewer's own empathy response. The neural correlates attributed to cognitive, motor and emotional empathy were the focus of the study. The methodology of using long duration stimuli in free viewing mode combined with ICA analysis has the potential to tease out spatially distributed but temporally coherent brain activity as demonstrated in this study. The independent components obtained from group ICA method isolated spatial maps with activations which can be safely ascribed to stimulus processing. We found that the activity in the areas attributable to cognitive and motor empathy was comparable for all the three stimuli while certain critical areas for emotional empathy were not noticed for the animation movie. These findings lead to interesting questions on possible differential emotion response in viewer(s) for computer generated actors compared to actors in live-action movies and the role of narrative and exposure to different genre of movies on racial, ethnic and cultural differences in empathy response. Copyright © 2015 Elsevier Inc. All rights reserved.
Bhatti, Mehwish Saba; Tang, Tong Boon; Chen, Hui Cheng
2018-04-09
In this study, we reported a new technique based on laser speckle flowgraphy to record the ocular blood flow in rabbits under deep anesthesia, and proposed parameters to characterize retinal ischemia. We applied the proposed technique to study the correlation of blood flow between the eyes of normal non-anesthetized animals, and to characterize the occlusion of the internal carotid artery (ICA) and external carotid artery (ECA). We established a correlation in blood flow between the eyes of non-anesthetized animals, and derived two new parameters, namely, the laterality index and vascular perfusion estimate (VPE). Our experimental results from 16 eyes (of 13 New Zealand white rabbits) showed a reduction in ocular blood flow with a significant decrease in the VPE after the occlusion of the ECA (p < 0.001). A low/minimal effect on blood flow was observed with the occlusion of the ICA. In conclusion, we demonstrated a means for the real-time measurement of the ocular blood flow in rabbits under deep anesthesia by using laser speckle flowgraphy and the VPE as an indicator of successful occlusion. The proposed technique might be applicable in quantifying the efficacy of new drugs and interventions for the treatment of retinal ischemia.
Doppler Audio Signal Analysis as an Additional Tool in Evaluation of Umbilical Artery Circulation.
Thuring, Ann; Källén, Karin; Brännström, K Jonas; Jansson, Tomas; Maršál, Karel
2017-10-01
Purpose To investigate the predictive capacity of a new method for sound spectrum analysis of Doppler signals recorded from the umbilical artery in high-risk pregnancies. Material and Methods The retrospective study comprised 127 pregnant women with various pregnancy complications between 23 and 39 gestational weeks. Umbilical artery blood flow velocity waveforms were recorded with Doppler ultrasound and characterized by pulsatility index (PI) and blood flow class (BFC). Doppler audio signals were stored on a digital video recorder and the sound frequency at the energy level 15 dB below its peak (MAX peak-15 dB ) was estimated off-line. The prediction of probability for composite adverse pregnancy outcome (operative delivery for fetal distress, admission to neonatal intensive care unit, perinatal death) was evaluated using the area under the curve (AUC) of the receiver operating characteristics (ROC) curve. Results With increasing umbilical artery BFC, the MAX peak-15 dB frequencies decreased (p < 0.0001) and the PI increased (p < 0.0001). The ROC AUCs for adverse outcome for MAX peak-15 dB and for PI were 0.842 and 0.836 (p = 0.88), respectively. For the combination of MAX peak-15 dB and PI, the corresponding AUC was 0.894, significantly higher than that of PI (p < 0.03) and of MAX peak-15 dB (p < 0.05). Conclusion Umbilical artery Doppler sound spectrum analysis might be a useful supplement to PI in the clinical evaluation of fetoplacental circulation. © Georg Thieme Verlag KG Stuttgart · New York.
2015-01-01
Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents. PMID:25754367
Morales, Maria-Aurora; Neglia, Danilo; L'Abbate, Antonio
2008-08-01
Myocardial blood flow during pharmacological vasodilatation is depressed in patients with idiopathic dilated cardiomyopathy even the in absence of overt heart failure; the extent of myocardial blood flow abnormalities is not predictable by left ventricular ejection fraction (LVEF) and diastolic dimensions. To assess whether myocardial blood flow impairment in idiopathic dilated cardiomyopathy without overt heart failure can be related to Doppler-derived dP/dt and to echocardiographically determined left ventricular end systolic stress - which is linked to myocardial blood flow reserve in advanced disease. Twenty-six patients, New York Heart Association Class I-II, (LVEF 37.4 +/- 1.4%, left ventricular diastolic dimensions 62.6 +/- 0.9 mm) underwent resting/dipyridamole [13N]NH3 flow positron emission tomography and an ultrasonic study. Regional myocardial blood flow values (ml/min per g) were computed from positron emission tomography data in 13 left ventricular (LV) myocardial regions and averaged to provide mean myocardial blood flow and myocardial blood flow reserve, defined as dipyridamole/resting mean myocardial blood flow ratio. Resting myocardial blood flow was 0.686 +/- 0.045, dipyridamole myocardial blood flow 1.39 +/- 0.15 and myocardial blood flow reserve 2.12 +/- 0.2, lower than in controls (P < 0.01). The ratio dP/dt was directly related to dipyridamole myocardial blood flow and myocardial blood flow reserve (r = 0.552 and 0.703, P < 0.005 and P < 0.0001); no relation was found between myocardial blood flow and LVEF left ventricular diastolic dimensions, and left ventricular end systolic stress. In idiopathic dilated cardiomyopathy patients without overt heart failure, the extent of myocardial blood flow reserve impairment is related to dP/dt but not to more classical indices of left ventricular function.
Fingerprint separation: an application of ICA
NASA Astrophysics Data System (ADS)
Singh, Meenakshi; Singh, Deepak Kumar; Kalra, Prem Kumar
2008-04-01
Among all existing biometric techniques, fingerprint-based identification is the oldest method, which has been successfully used in numerous applications. Fingerprint-based identification is the most recognized tool in biometrics because of its reliability and accuracy. Fingerprint identification is done by matching questioned and known friction skin ridge impressions from fingers, palms, and toes to determine if the impressions are from the same finger (or palm, toe, etc.). There are many fingerprint matching algorithms which automate and facilitate the job of fingerprint matching, but for any of these algorithms matching can be difficult if the fingerprints are overlapped or mixed. In this paper, we have proposed a new algorithm for separating overlapped or mixed fingerprints so that the performance of the matching algorithms will improve when they are fed with these inputs. Independent Component Analysis (ICA) has been used as a tool to separate the overlapped or mixed fingerprints.
Grudzińska, Ewa; Modrzejewska, Monika
2018-01-01
Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the
Wang, Yimin; Fawzi, Amani A.; Varma, Rohit; Sadun, Alfredo A.; Zhang, Xinbo; Tan, Ou; Izatt, Joseph A.
2011-01-01
Purpose. To investigate blood flow changes in retinal and optic nerve diseases with Doppler Fourier domain optical coherence tomography (OCT). Methods. Sixty-two participants were divided into five groups: normal, glaucoma, nonarteritic ischemic optic neuropathy (NAION), treated proliferative diabetic retinopathy (PDR), and branch retinal vein occlusion (BRVO). Doppler OCT was used to scan concentric circles of 3.4- and 3.75-mm diameters around the optic nerve head. Flow in retinal veins was calculated from the OCT velocity profiles. Arterial and venous diameters were measured from OCT Doppler and reflectance images. Results. Total retinal blood flow in normal subjects averaged 47.6 μL/min. The coefficient of variation of repeated measurements was 11% in normal eyes and 14% in diseased eyes. Eyes with glaucoma, NAION, treated PDR, and BRVO had significantly decreased retinal blood flow compared with normal eyes (P < 0.001). In glaucoma patients, the decrease in blood flow was highly correlated with the severity of visual field loss (P = 0.003). In NAION and BRVO patients, the hemisphere with more severe disease also had lower blood flow. Conclusions. Doppler OCT retinal blood flow measurements showed good repeatability and excellent correlation with visual field and clinical presentations. This approach could enhance our understanding of retinal and optic nerve diseases and facilitate the development of new therapies. PMID:21051715
Naik, Ganesh R; Kumar, Dinesh K; Arjunan, Sridhar
2009-01-01
This paper has experimentally verified and compared features of sEMG (Surface Electromyogram) such as ICA (Independent Component Analysis) and Fractal Dimension (FD) for identification of low level forearm muscle activities. The fractal dimension was used as a feature as reported in the literature. The normalized feature values were used as training and testing vectors for an Artificial neural network (ANN), in order to reduce inter-experimental variations. The identification accuracy using FD of four channels sEMG was 58%, and increased to 96% when the signals are separated to their independent components using ICA.
A new laser Doppler flowmeter prototype for depth dependent monitoring of skin microcirculation
NASA Astrophysics Data System (ADS)
Figueiras, E.; Campos, R.; Semedo, S.; Oliveira, R.; Requicha Ferreira, L. F.; Humeau-Heurtier, A.
2012-03-01
Laser Doppler flowmetry (LDF) is now commonly used in clinical research to monitor microvascular blood flow. However, the dependence of the LDF signal on the microvascular architecture is still unknown. That is why we propose a new laser Doppler flowmeter for depth dependent monitoring of skin microvascular perfusion. This new laser Doppler flowmeter combines for the first time, in a device, several wavelengths and different spaced detection optical fibres. The calibration of the new apparatus is herein presented together with in vivo validation. Two in vivo validation tests are performed. In the first test, signals collected in the ventral side of the forearm are analyzed; in the second test, signals collected in the ventral side of the forearm are compared with signals collected in the hand palm. There are good indicators that show that different wavelengths and fibre distances probe different skin perfusion layers. However, multiple scattering may affect the results, namely the ones obtained with the larger fibre distance. To clearly understand the wavelength effect in LDF measurements, other tests have to be performed.
Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk
2015-01-01
Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135
NASA Technical Reports Server (NTRS)
Beyon, Jeffrey Y.; Koch, Grady J.
2006-01-01
The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.
Hoscheidt, Siobhan M; Kellawan, J Mikhail; Berman, Sara E; Rivera-Rivera, Leonardo A; Krause, Rachel A; Oh, Jennifer M; Beeri, Michal S; Rowley, Howard A; Wieben, Oliver; Carlsson, Cynthia M; Asthana, Sanjay; Johnson, Sterling C; Schrage, William G
2016-01-01
Insulin resistance (IR) is associated with poor cerebrovascular health and increased risk for dementia. Little is known about the unique effect of IR on both micro- and macrovascular flow particularly in midlife when interventions against dementia may be most effective. We examined the effect of IR as indexed by the Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) on cerebral blood flow in macro- and microvessels utilizing magnetic resonance imaging (MRI) among cognitively asymptomatic middle-aged individuals. We hypothesized that higher HOMA-IR would be associated with reduced flow in macrovessels and lower cortical perfusion. One hundred and twenty cognitively asymptomatic middle-aged adults (57 ± 5 yrs) underwent fasting blood draw, phase contrast-vastly undersampled isotropic projection reconstruction (PC VIPR) MRI, and arterial spin labeling (ASL) perfusion. Higher HOMA-IR was associated with lower arterial blood flow, particularly within the internal carotid arteries (ICAs), and lower cerebral perfusion in several brain regions including frontal and temporal lobe regions. Higher blood flow in bilateral ICAs predicted greater cortical perfusion in individuals with lower HOMA-IR, a relationship not observed among those with higher HOMA-IR. Findings provide novel evidence for an uncoupling of macrovascular blood flow and microvascular perfusion among individuals with higher IR in midlife. PMID:27488909
IIP Update: A Packaged Coherent Doppler Wind Lidar Transceiver. Doppler Aerosol WiNd Lidar (DAWN)
NASA Technical Reports Server (NTRS)
Kavaya, Michael J.; Koch, Grady J.; Yu, Jirong; Trieu, Bo C.; Amzajerdian, Farzin; Singh, Upendra N.; Petros, Mulugeta
2006-01-01
The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.
Hack, Henrik
2006-08-01
The anesthetic management of pheochromocytoma has been based upon the intraoperative control of blood pressure and fluid balance following adequate preoperative preparation. This can be difficult, especially in the presence of significant comorbidity such as cardiac or renal dysfunction. Two cases of children with pheochromocytoma are reported where the introperative management of fluid balance and blood pressure control were guided by measurement of changes in descending aortic blood flow using an esophageal Doppler probe. The advantages of such a technique compared with more invasive monitors are discussed.
Sakamoto, Shigeyuki; Kiura, Yoshihiro; Okazaki, Takahito; Shinagawa, Katsuhiro; Ichinose, Nobuhiko; Shibukawa, Masaaki; Orita, Yoji; Shimonaga, Koji; Kajihara, Yosuke; Kurisu, Kaoru
2015-03-01
We describe dual protection (simultaneous flow reversal and distal filter) combined with blood aspiration as a novel technique to provide distal embolic protection during carotid artery stenting (CAS). Between July 2011 and August 2014, 190 patients with internal carotid artery (ICA) stenosis underwent 190 CAS procedures as follows. After post-dilation of the stent using dual protection, the aspiration catheter was placed between the distal filter and the proximal end of the stent, and the blood was aspirated several times from the ICA. We assessed hyper-intensity spots in diffusion-weighted images (DWI), and major adverse events (MAE) defined as major stroke, myocardial infarction and death after CAS. We then assessed visible debris captured in aspirated blood, the distal filter and a blood filter during flow reversal. The overall technical success rate was 100 %, and all stenoses were dilated. Hyper-intense spots were found in 33 (17.3 %) of 190 DWI. The rate of MAE within 30 days was 1.05 % (2/190). Visible debris in 175 of 190 CAS procedures was captured in 92 (52.5 %) of these 175. In 25 (27.2 %) of these 92, visible debris was captured in all of aspirated blood, the distal filter and the blood filter during flow reversal, only the blood filter during flow reversal (n = 19; 20.7 %), only the distal filter (n = 14; 15.2 %), only aspirated blood (n = 11; 12 %), aspirated blood and the blood filter during flow reversal (n = 10; 10.8 %), aspirated blood and the distal filter (n = 7; 7.6 %) and the distal filter and blood filter during flow reversal (n = 6; 6.5 %). Adding a distal filter and blood aspiration to flow reversal during CAS could provide effective distal embolic protection.
Griffanti, Ludovica; Salimi-Khorshidi, Gholamreza; Beckmann, Christian F; Auerbach, Edward J; Douaud, Gwenaëlle; Sexton, Claire E; Zsoldos, Enikő; Ebmeier, Klaus P; Filippini, Nicola; Mackay, Clare E; Moeller, Steen; Xu, Junqian; Yacoub, Essa; Baselli, Giuseppe; Ugurbil, Kamil; Miller, Karla L; Smith, Stephen M
2014-07-15
The identification of resting state networks (RSNs) and the quantification of their functional connectivity in resting-state fMRI (rfMRI) are seriously hindered by the presence of artefacts, many of which overlap spatially or spectrally with RSNs. Moreover, recent developments in fMRI acquisition yield data with higher spatial and temporal resolutions, but may increase artefacts both spatially and/or temporally. Hence the correct identification and removal of non-neural fluctuations is crucial, especially in accelerated acquisitions. In this paper we investigate the effectiveness of three data-driven cleaning procedures, compare standard against higher (spatial and temporal) resolution accelerated fMRI acquisitions, and investigate the combined effect of different acquisitions and different cleanup approaches. We applied single-subject independent component analysis (ICA), followed by automatic component classification with FMRIB's ICA-based X-noiseifier (FIX) to identify artefactual components. We then compared two first-level (within-subject) cleaning approaches for removing those artefacts and motion-related fluctuations from the data. The effectiveness of the cleaning procedures was assessed using time series (amplitude and spectra), network matrix and spatial map analyses. For time series and network analyses we also tested the effect of a second-level cleaning (informed by group-level analysis). Comparing these approaches, the preferable balance between noise removal and signal loss was achieved by regressing out of the data the full space of motion-related fluctuations and only the unique variance of the artefactual ICA components. Using similar analyses, we also investigated the effects of different cleaning approaches on data from different acquisition sequences. With the optimal cleaning procedures, functional connectivity results from accelerated data were statistically comparable or significantly better than the standard (unaccelerated) acquisition, and
NASA Astrophysics Data System (ADS)
Meglič, P.; Brenčič, M.
2012-04-01
River I\\vska and Ižica karstic springs are situated in the central part of Slovenia (approximately 20 km south from city Ljubljana) on southern edge of Barje, a tectonic depression field with mostly Holocene and Pleistocene lacustrine and rivers' sediments. Barje is surrounded with hills, which on the southern part consists mostly of Triassic dolomite and Jurassic limestone as well as the basement of Barje in this area. Recharge area of I\\vska River and Ižica karstic springs is covering around 102 km2 of the southern hilly edge of Barje. I\\vska River is a torrent with springs on Blo\\vska planota and flows towards Barje to the north. River formed deep narrow valley that slightly opens at the beginning of I\\vski Vintgar, where flows on a shallow gravel river bed deposited on karstic aquifer. The valley opens on Ljubljansko Barje at village I\\vska vas. Ižica karstic springs are situated on the contact of karst aquifer and Barje intergranular aquifer east of I\\vska valley. After a big flood event on 18th of September 2010 I\\vska River disappeared in the karstic fissures on the river bottom, near bridge in I\\vska village. One day later infiltration point moved 1070 meters upstream. This extreme event caused around 40% higher base flow discharge of Ižica River and total disappearance of I\\vska River for a few days. The analyzed discharge data in the year 2010 of the I\\vska and Ižica River, gave a new understanding of the discharge of I\\vska River and groundwater flow in the area. Before this extreme event discharge of the I\\vska River was measured at different profiles in the channel and reduction of discharge was observed along the course indicating that I\\vska recharges Ižica springs. Analyses presented were performed in the frame of INCOME project and are aimed to improve understanding of hydrogeological conditions in the catchment area of Barje aquifer which is exploited for the public water supply of Ljubljana.
Preoperative color Doppler assessment in planning of gluteal perforator flaps.
Isken, Tonguc; Alagoz, M Sahin; Onyedi, Murat; Izmirli, Hakki; Isil, Eda; Yurtseven, Nagehan
2009-02-01
Gluteal artery perforator flaps have gained popularity due to reliability, preservation of the muscle, versatility in flap design without restricting other flap options, and low donor-site morbidity in ambulatory patients and possibility of enabling future reconstruction in paraplegic patients. But the inconstant anatomy of the vascular plexus around the gluteal muscle makes it hard to predict how many perforators are present, what their volume of blood flow and size are, where they exit the overlying fascia, and what their course through the muscle will be. Without any prior investigations, the reconstructive surgeon could be surprised intraoperatively by previous surgical damage, scar formation, or anatomic variants.For these reasons, to confirm the presence and the location of gluteal perforators preoperatively we have used color Doppler ultrasonography. With the help of the color Doppler ultrasonography 26 patients, 21 men and 5 women, were operated between the years 2002 and 2007. The mean age of patients was 47.7 (age range: 7-77 years). All perforator vessels were marked preoperatively around the defect locations. The perforator based flap that will allow primary closure of the donor site and the defect without tension was planned choosing the perforator that showed the largest flow in color Doppler ultrasonography proximally. Perforators were found in the sites identified with color Doppler ultrasonography in all other flaps. In our study, 94.4% flap viability was ensured in 36 perforator-based gluteal area flaps. Mean flap elevation time was 31.9 minutes. We found that locating the perforators preoperatively helps to shorten the operation time without compromising a reliable viability of the perforator flaps, thus enabling the surgeon easier treatment of pressure sores.
Enhancement of IVR images by combining an ICA shrinkage filter with a multi-scale filter
NASA Astrophysics Data System (ADS)
Chen, Yen-Wei; Matsuo, Kiyotaka; Han, Xianhua; Shimizu, Atsumoto; Shibata, Koichi; Mishina, Yukio; Mukuta, Yoshihiro
2007-11-01
Interventional Radiology (IVR) is an important technique to visualize and diagnosis the vascular disease. In real medical application, a weak x-ray radiation source is used for imaging in order to reduce the radiation dose, resulting in a low contrast noisy image. It is important to develop a method to smooth out the noise while enhance the vascular structure. In this paper, we propose to combine an ICA Shrinkage filter with a multiscale filter for enhancement of IVR images. The ICA shrinkage filter is used for noise reduction and the multiscale filter is used for enhancement of vascular structure. Experimental results show that the quality of the image can be dramatically improved without any blurring in edge by the proposed method. Simultaneous noise reduction and vessel enhancement have been achieved.
Sarrami-Foroushani, Ali; Lassila, Toni; Gooya, Ali; Geers, Arjan J; Frangi, Alejandro F
2016-12-08
Adverse wall shear stress (WSS) patterns are known to play a key role in the localisation, formation, and progression of intracranial aneurysms (IAs). Complex region-specific and time-varying aneurysmal WSS patterns depend both on vascular morphology as well as on variable systemic flow conditions. Computational fluid dynamics (CFD) has been proposed for characterising WSS patterns in IAs; however, CFD simulations often rely on deterministic boundary conditions that are not representative of the actual variations in blood flow. We develop a data-driven statistical model of internal carotid artery (ICA) flow, which is used to generate a virtual population of waveforms used as inlet boundary conditions in CFD simulations. This allows the statistics of the resulting aneurysmal WSS distributions to be computed. It is observed that ICA waveform variations have limited influence on the time-averaged WSS (TAWSS) on the IA surface. In contrast, in regions where the flow is locally highly multidirectional, WSS directionality and harmonic content are strongly affected by the ICA flow waveform. As a consequence, we argue that the effect of blood flow variability should be explicitly considered in CFD-based IA rupture assessment to prevent confounding the conclusions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Doppler Fourier Domain Optical Coherence Tomography for Label-Free Tissue Angiography
NASA Astrophysics Data System (ADS)
Leitgeb, Rainer A.; Szkulmowski, Maciej; Blatter, Cedric; Wojtkowski, Maciej
Information about tissue perfusion and the vascular structure is certainly most important for assessment of tissue state or personal health and the diagnosis of any pathological conditions. It is therefore of key medical interest to have tools available for both quantitative blood flow assessment as well as qualitative vascular imaging. The strength of optical techniques is the unprecedented level of detail even for small capillary structures or microaneurysms and the possibility to combine different techniques for additional tissue spectroscopy giving insight into tissue metabolism. There is an immediate diagnostic and pharmacological demand for high-resolution, label-free, tissue angiography and flow assessment that in addition allow for precise depth gating of flow information. The most promising candidate is Doppler optical coherence tomography (DOCT) being noncontact, label free, and without employing hazardous radiation. DOCT provides fully quantitative volumetric information about blood flow together with the vascular and structural anatomy. Besides flow quantification, analysis of OCT signal fluctuations allows to contrast moving scatterers in tissue such as red blood cells from static tissue. This allows for non-invasive optical angiography and yields high resolution even for smallest capillaries. Because of the huge potential of DOCT and lable-free optical angiography for diagnosis, the last years saw a rapid increase of publications in this field with many different approaches. The present chapter gives an overview over existing Doppler OCT approaches and angiography techniques. It furthermore discusses limitations and noise issues, and gives examples for angiography in the eye and the skin.
Improving Classroom Acoustics (ICA): A Three-Year FM Sound Field Classroom Amplification Study.
ERIC Educational Resources Information Center
Rosenberg, Gail Gegg; Blake-Rahter, Patricia; Heavner, Judy; Allen, Linda; Redmond, Beatrice Myers; Phillips, Janet; Stigers, Kathy
1999-01-01
The Improving Classroom Acoustics (ICA) special project was designed to determine if students' listening and learning behaviors improved as a result of an acoustical environment enhanced through the use of FM sound field classroom amplification. The 3-year project involved 2,054 students in 94 general education kindergarten, first-, and…
A World Worth Living in ICAE 8th World Assembly Declaration (June 2011)
ERIC Educational Resources Information Center
Adult Learning, 2012
2012-01-01
This article presents the International Council of Adult Education (ICAE) 8th World Assembly Declaration (June 2011). This declaration focuses on adult educators' conviction in the possibility of a "world worth living in," and their declaration of their collective determination to work towards making it a reality all around the planet.
Cerebrovascular response to the cold pressor test - the critical role of carbon dioxide.
Tymko, Michael M; Kerstens, Thijs P; Wildfong, Kevin W; Ainslie, Philip N
2017-12-01
What is the central question of this study? What is the role of carbon dioxide in the cerebral blood flow (CBF) response to the cold pressor test (CPT)? What is the main finding and its importance? The CBF response was elevated during the isocapnic (controlled CO 2 ) CPT in the middle cerebral artery and the internal carotid artery compared with the poikilocapnic (uncontrolled CO 2 ) CPT, owing to ventilation-associated reductions in end-tidal CO 2 . Furthermore, the common carotid artery vasodilated to a greater extent during the isocapnic compared with the poikilocapnic CPT, whereas the internal carotid artery vasoconstricted during both CPTs. Our data highlight the importance of CO 2 control when investigating the CBF response to the CPT. In addition to increasing sympathetic nervous activity, blood pressure and cerebral blood flow (CBF), the cold pressor test (CPT) stimulates pain receptors, which may increase ventilation above metabolic demand; this response is likely to reduce the partial pressure of end-tidal carbon dioxide (P ET ,CO2) and will attenuate elevations in CBF. Our hypotheses were as follows: (i) the CPT will elicit hyperventilation, effectively lowering P ET ,CO2; (ii) the CBF response will be elevated during an isocapnic (controlled P ET ,CO2) compared with a poikilocapnic CPT (uncontrolled P ET ,CO2); and (iii) in response to the CPT, the common carotid artery (CCA) will vasodilate, while the internal carotid artery (ICA) will remain unchanged to help regulate CBF. Using a new, randomized experimental design, we measured the cerebrovascular response in the middle cerebral artery (MCA), CCA and internal carotid artery (ICA), during an isocapnic and poikilocapnic CPT in 15 participants. Blood pressure and cardiac output (finger photoplethysmography), heart rate (ECG), MCA mean velocity (transcranial Doppler ultrasound) and CCA and ICA CBF (Duplex ultrasound) were recorded during both CPT trials. Our findings were as follows: (i) ventilation
Laser Doppler perfusion imaging: a method for measuring female sexual response.
Styles, S J; Maclean, A B; Reid, W M N; Sultana, S R
2006-05-01
To develop a new noninvasive technique to measure vulval blood flow changes during sexual arousal; 18 healthy volunteers between the age of 20 and 33 years were studied. Each subject underwent two experimental sessions at least 2 weeks apart to coincide with the proliferative and luteal phases of her menstrual cycle. An initial laser Doppler perfusion imaging (LDPI) scan of the vulva was performed. The subject was then given a chapter of erotic fiction to read and a repeat LDPI scan was performed immediately after. The percentage change in flux were calculated: the clitoral skin blood flow increased by 26.4% (P < 0.05), labial skin blood flow by 24.9% (P < 0.05) and the posterior fourchette skin blood flow by 35.3% (P < 0.05). LDPI can detect changes in vulval perfusion during the sexual arousal response and could be used to compare healthy subjects with female sexual dysfunction patients, as well as for assessing the benefits of any treatment for this condition.
Motion artifact removal algorithm by ICA for e-bra: a women ECG measurement system
NASA Astrophysics Data System (ADS)
Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.
2013-04-01
Wearable ECG(ElectroCardioGram) measurement systems have increasingly been developing for people who suffer from CVD(CardioVascular Disease) and have very active lifestyles. Especially, in the case of female CVD patients, several abnormal CVD symptoms are accompanied with CVDs. Therefore, monitoring women's ECG signal is a significant diagnostic method to prevent from sudden heart attack. The E-bra ECG measurement system from our previous work provides more convenient option for women than Holter monitor system. The e-bra system was developed with a motion artifact removal algorithm by using an adaptive filter with LMS(least mean square) and a wandering noise baseline detection algorithm. In this paper, ICA(independent component analysis) algorithms are suggested to remove motion artifact factor for the e-bra system. Firstly, the ICA algorithms are developed with two kinds of statistical theories: Kurtosis, Endropy and evaluated by performing simulations with a ECG signal created by sgolayfilt function of MATLAB, a noise signal including 0.4Hz, 1.1Hz and 1.9Hz, and a weighed vector W estimated by kurtosis or entropy. A correlation value is shown as the degree of similarity between the created ECG signal and the estimated new ECG signal. In the real time E-Bra system, two pseudo signals are extracted by multiplying with a random weighted vector W, the measured ECG signal from E-bra system, and the noise component signal by noise extraction algorithm from our previous work. The suggested ICA algorithm basing on kurtosis or entropy is used to estimate the new ECG signal Y without noise component.
Doppler characteristics of sea clutter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raynal, Ann Marie; Doerry, Armin Walter
2010-06-01
Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristicsmore » of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.« less
NASA Astrophysics Data System (ADS)
Folgosi-Correa, M. S.; Nogueira, G. E. C.
2012-06-01
The laser Doppler flowmetry allows the non-invasive assessment of the skin perfusion in real-time, being an attractive technique to study the human microcirculation in clinical settings. Low-frequency oscillations in the laser Doppler blood flow signal from the skin have been related to the endothelial, endothelial-metabolic, neurogenic and myogenic mechanisms of microvascular flow control, in the range 0.005-0.0095 Hz, 0.0095-0.021 Hz, 0.021-0.052 Hz and 0.052- 0.145 Hz respectively. The mean Amplitude (A) of the periodic fluctuations in the laser Doppler blood flow signal, in each frequency range, derived from the respective wavelet-transformed coefficients, has been used to assess the function and dysfunctions of each mechanism of flow control. Known sources of flow signal variances include spatial and temporal variability, diminishing the discriminatory capability of the technique. Here a new time domain method of analysis is proposed, based on the Time of Correlation (TC) of flow fluctuations between two adjacent sites. Registers of blood flow from two adjacent regions, for skin temperature at 32 0C (basal) and thermally stimulated (42 0C) of volar forearms from 20 healthy volunteers were collected and analyzed. The results obtained revealed high time of correlation between two adjacent regions when thermally stimulated, for signals in the endothelial, endothelial-metabolic, neurogenic and myogenic frequency ranges. Experimental data also indicate lower variability for TC when compared to A, when thermally stimulated, suggesting a new promising parameter for assessment of the microvascular flow control.
Changes in blood velocity following microvascular free tissue transfer.
Hanasono, Matthew M; Ogunleye, Olubunmi; Yang, Justin S; Hartley, Craig J; Miller, Michael J
2009-09-01
Understanding how pedicle blood velocities change after free tissue transfer may enable microvascular surgeons to predict when thrombosis is most likely to occur. A 20-MHz Doppler probe was used to measure arterial and venous blood velocities prior to pedicle division and 20 minutes after anastomosis in 32 microvascular free flaps. An implantable Doppler probe was then used to measure arterial and venous blood velocities daily for 5 days. Peak arterial blood velocity averaged 30.6 cm/s prior to pedicle division and increased to 36.5 cm/s 20 minutes after anastomosis ( P < 0.05). Peak venous blood velocity averaged 7.6 cm/s prior to pedicle division and increased to 12.4 cm/s 20 minutes after anastomosis ( P < 0.05). Peak arterial blood velocities averaged 34.0, 37.7, 43.8, 37.9, 37.6 cm/s on postoperative days (PODs) 1 through 5, respectively. Peak venous blood velocities averaged 11.9, 14.5, 18.2, 16.8, 17.7 cm/s on PODs 1 through 5, respectively. The peak arterial blood velocity on POD 3, and peak venous blood velocities on PODs 2, 3, and 5 were significantly higher than 20 minutes after anastomosis ( P < 0.05). Arterial and venous blood velocities increase for the first 3 postoperative days, potentially contributing to the declining risk for pedicle thrombosis during this time period.
Eyeballing oscillators for pulsed Doppler radar
NASA Astrophysics Data System (ADS)
Goldman, S.
1985-03-01
The visibility of small targets to a Doppler radar system in the presence of large targets is limited by phase noise. Such limitations occur when an airborne radar searches the ground for a mobile vehicle. Under these conditions, the performance of the Doppler radar depends greatly on the specifications of its phased-locked oscillator. Goldman (1984) has discussed the steps required to evaluate the noise resulting from a pulsed Doppler radar system. In the present investigation, these techniques are applied in reverse to determine system specifications for oscillator noise. A 95-GHz pulsed Doppler radar system is used as an example of specifying system phase noise.
Le Bars, Pierre; Niagha, Gaston; Kouadio, Ayepa Alain; Demoersman, Julien; Roy, Elisabeth; Armengol, Valérie; Soueidan, Assem
2016-01-01
Background. Histopathological alterations can arise when the denture-supporting mucosa experiences microbial and mechanical stress through the denture base and diagnosis of these diseases usually follows microvascular changes. Microcirculation measurement could allow for detection of such dysfunction and aid in the early diagnosis of palatal mucosa pathologies. Materials and Methods. We tested the sensitivity of laser Doppler for measuring the microcirculation of the palatal mucosa, assessing the median raphe (MR), Schroeder area (SA), and retroincisive papilla (RP). A Doppler PeriFlux 5000 System, containing a laser diode, was used. 54 healthy participants were recruited. We compare the measurements of PU (perfusion unit) using ANOVA test. Results. The numerical values for palatal mucosa blood flow differed significantly among the anatomical areas (p = 0.0167). The mean value of Schroeder area was 92.6 (SD: 38.4) and was significantly higher than the retroincisive papilla (51.9) (SD: 20.2) (p < 0.05), which in turn was higher than that of median raphe (31.9) (SD: 24.2) (p < 0.0001). Conclusion. Schroeder area appeared to have the greatest sensitivity, and vascular flow variability among individuals was also greatest in this region. We suggest that analysis of blood stream modification with laser Doppler of the palatal mucosa can help to detect onset signs of pathological alterations. PMID:27340663
Childhood cognitive development after fetal growth restriction.
Llurba, E; Baschat, A A; Turan, O M; Harding, J; McCowan, L M
2013-04-01
To examine the relationship between prenatal umbilical artery (UA) and internal carotid artery (ICA) Doppler findings and cognitive development at 3 and 6 years in low-birth-weight children. This was a study of 209 low-birth-weight (< 10(th) centile) children born after 28 gestational weeks with UA resistance index (RI) measured within 2 weeks before delivery. Children with normal UA- and ICA-RI were defined as small-for-gestational age (SGA) and those with abnormal UA or ICA Doppler findings as having fetal growth restriction (FGR). Cognitive ability at 3 and 6 years' corrected age was assessed using the fourth edition of the Stanford-Binet Intelligence Scale (SBIS) and compared between SGA and FGR groups. An SBIS score < 85 was considered to indicate delayed development. The median gestational age at diagnosis of abnormal fetal growth was 36.6 (range, 28-41) weeks. There were 87 (41.6%) children classified as having FGR and 122 (58.4%) as SGA. The mean global SBIS score at 3 years was 109.4 (SD, 22.8) and at 6 years it was 110.5 (SD, 13.9). Overall, 22 (10.5%) children had delayed development at 3 years. Total SBIS scores and individual domain scores did not differ between FGR and SGA groups at 3 or 6 years and similar proportions in each group had delayed development. Abnormal prenatal UA and ICA Doppler findings are not associated with lower developmental scores in low-birth-weight children delivered in the third trimester of pregnancy. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.
Calhoun, Vince D; Kiehl, Kent A; Pearlson, Godfrey D
2008-07-01
Brain regions which exhibit temporally coherent fluctuations, have been increasingly studied using functional magnetic resonance imaging (fMRI). Such networks are often identified in the context of an fMRI scan collected during rest (and thus are called "resting state networks"); however, they are also present during (and modulated by) the performance of a cognitive task. In this article, we will refer to such networks as temporally coherent networks (TCNs). Although there is still some debate over the physiological source of these fluctuations, TCNs are being studied in a variety of ways. Recent studies have examined ways TCNs can be used to identify patterns associated with various brain disorders (e.g. schizophrenia, autism or Alzheimer's disease). Independent component analysis (ICA) is one method being used to identify TCNs. ICA is a data driven approach which is especially useful for decomposing activation during complex cognitive tasks where multiple operations occur simultaneously. In this article we review recent TCN studies with emphasis on those that use ICA. We also present new results showing that TCNs are robust, and can be consistently identified at rest and during performance of a cognitive task in healthy individuals and in patients with schizophrenia. In addition, multiple TCNs show temporal and spatial modulation during the cognitive task versus rest. In summary, TCNs show considerable promise as potential imaging biological markers of brain diseases, though each network needs to be studied in more detail. (c) 2008 Wiley-Liss, Inc.
Calhoun, Vince D.; Kiehl, Kent A.; Pearlson, Godfrey D.
2009-01-01
Brain regions which exhibit temporally coherent fluctuations, have been increasingly studied using functional magnetic resonance imaging (fMRI). Such networks are often identified in the context of an fMRI scan collected during rest (and thus are called “resting state networks”); however, they are also present during (and modulated by) the performance of a cognitive task. In this article, we will refer to such networks as temporally coherent networks (TCNs). Although there is still some debate over the physiological source of these fluctuations, TCNs are being studied in a variety of ways. Recent studies have examined ways TCNs can be used to identify patterns associated with various brain disorders (e.g. schizophrenia, autism or Alzheimer’s disease). Independent component analysis (ICA) is one method being used to identify TCNs. ICA is a data driven approach which is especially useful for decomposing activation during complex cognitive tasks where multiple operations occur simultaneously. In this article we review recent TCN studies with emphasis on those that use ICA. We also present new results showing that TCNs are robust, and can be consistently identified at rest and during performance of a cognitive task in healthy individuals and in patients with schizophrenia. In addition, multiple TCNs show temporal and spatial modulation during the cognitive task versus rest. In summary, TCNs show considerable promise as potential imaging biological markers of brain diseases, though each network needs to be studied in more detail. PMID:18438867
NASA Astrophysics Data System (ADS)
Todea, Carmen; Sarpe, Amalia; Vitez, Bogdan; Draganescu, Gheorghe
2014-01-01
The present study aims to assess the pulp vitality before and after different tooth bleaching procedures, in order to determine the changes in pulpal microcirculation and whether they are reversible or not. Twelve volunteers were included in this study. For each volunteer, the pulpal blood flow of maxillary teeth was assessed prior to treatment using Laser Doppler Flowmetry. The "in office" bleaching technique was used 6 anterior teeth, with two different gels, a conventional one chemically activated (Group I 3teeth) and another one activated using Nd:YAG laser (Group II-3 teeth). The bleaching agents were applied on counterpart teeth and, after obtaining a esthetic results for each tooth, the pulpal blood flow was assessed using Laser Doppler Flowmetry immediately after treatment and then after one day and one week. All data were collected and statistically analyzed. Immediately after treatment, the assessment showed an increase of pulpal blood flow, for both study groups, but higher in Group I as compared to Group II (p<0.005). The subsequent assessments showed a reduction of the pulpal blood flow with non - significant differences between the study groups (p<0.005).The results suggest that the tooth bleaching procedurere presents a safe treatment method, which does not lead to irreversible damage to the dental pulp, when used correctly.
The effect of prazosin on skin microcirculation as assessed by laser Doppler flowmetry.
Khan, F; Struthers, A D; Spence, V A
1988-01-01
1. Laser Doppler flowmetry was used in six normal volunteers to record changes in fingertip skin blood flow after the administration of prazosin to block postsynaptic alpha 1-adrenoceptors. 2. Prazosin (0.5 mg orally) did not alter systolic or diastolic blood pressure or heart rate. 3. Prazosin did significantly increase basal skin blood flow 2 h after its administration but this effect was no longer evident after contralateral hand warming. Prazosin markedly reduced the skin vasoconstrictor response to deep inspiration and to contralateral hand cooling. 4. This study suggests that postsynaptic alpha 1-adrenoceptors are involved in maintaining skin vasoconstrictor tone at rest and are also involved in the rapid skin vasoconstriction seen in response to a deep inspiration and to contralateral hand cooling. PMID:2846022
ERIC Educational Resources Information Center
Illingworth, Sarah; Bishop, Dorothy V. M.
2009-01-01
Functional transcranial Doppler ultrasound (fTCD) is a relatively new and non-invasive technique that assesses cerebral lateralisation through measurements of blood flow velocity in the middle cerebral arteries. In this study fTCD was used to compare functional asymmetry during a word generation task between a group of 30 dyslexic adults and a…
Automated EEG artifact elimination by applying machine learning algorithms to ICA-based features
NASA Astrophysics Data System (ADS)
Radüntz, Thea; Scouten, Jon; Hochmuth, Olaf; Meffert, Beate
2017-08-01
Objective. Biological and non-biological artifacts cause severe problems when dealing with electroencephalogram (EEG) recordings. Independent component analysis (ICA) is a widely used method for eliminating various artifacts from recordings. However, evaluating and classifying the calculated independent components (IC) as artifact or EEG is not fully automated at present. Approach. In this study, we propose a new approach for automated artifact elimination, which applies machine learning algorithms to ICA-based features. Main results. We compared the performance of our classifiers with the visual classification results given by experts. The best result with an accuracy rate of 95% was achieved using features obtained by range filtering of the topoplots and IC power spectra combined with an artificial neural network. Significance. Compared with the existing automated solutions, our proposed method is not limited to specific types of artifacts, electrode configurations, or number of EEG channels. The main advantages of the proposed method is that it provides an automatic, reliable, real-time capable, and practical tool, which avoids the need for the time-consuming manual selection of ICs during artifact removal.
Automated EEG artifact elimination by applying machine learning algorithms to ICA-based features.
Radüntz, Thea; Scouten, Jon; Hochmuth, Olaf; Meffert, Beate
2017-08-01
Biological and non-biological artifacts cause severe problems when dealing with electroencephalogram (EEG) recordings. Independent component analysis (ICA) is a widely used method for eliminating various artifacts from recordings. However, evaluating and classifying the calculated independent components (IC) as artifact or EEG is not fully automated at present. In this study, we propose a new approach for automated artifact elimination, which applies machine learning algorithms to ICA-based features. We compared the performance of our classifiers with the visual classification results given by experts. The best result with an accuracy rate of 95% was achieved using features obtained by range filtering of the topoplots and IC power spectra combined with an artificial neural network. Compared with the existing automated solutions, our proposed method is not limited to specific types of artifacts, electrode configurations, or number of EEG channels. The main advantages of the proposed method is that it provides an automatic, reliable, real-time capable, and practical tool, which avoids the need for the time-consuming manual selection of ICs during artifact removal.
Cournane, S; Fagan, A J; Browne, J E
2014-05-01
Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Rankine-Mullings, Angela E; Morrison-Levy, Nadine; Soares, Deanne; Aldred, Karen; King, Lesley; Ali, Susanna; Knight-Madden, Jennifer M; Wisdom-Phipps, Margaret; Adams, Robert J; Ware, Russell E; Reid, Marvin
2018-04-01
This study investigated the association of nutritional and haematological variables with maximum time-averaged mean velocity (TAMV) measured by transcranial Doppler (TCD) velocity and the agreement of classification between two protocols. TCD categories included: normal (<170 cm/s), conditional (170-199 cm/s) and abnormal (≥200 cm/s) based on TAMV in distal internal carotid artery (dICA), middle cerebral artery (MCA), internal carotid bifurcation, anterior and posterior cerebral arteries. Of 358 children with sickle cell anaemia (SCA) examined, the mean age (±standard deviation) was 7·4 ± 2·7 years; 13·1% and 6·7% had conditional and abnormal velocities, respectively. Children with abnormal TCD velocities had higher prevalence of prior stroke (P = 0·006). Increased TAMV was associated with younger age (P = 0·001), lower weight (P = 0·001), height (P = 0·007) and oxygen saturation (P = 0·005). There was no association of TAMV with height-age or body mass index (BMI) z-scores. Adjusting for gender, BMI z-score, age, previous stroke and oxygen saturation, mean corpuscular volume (P = 0·005) and reticulocyte count (P = 0·013) were positively associated with TAMV, while haemoglobin concentration (P = 0·009) was negatively associated. There was good agreement [99%; weighted Kappa 0·98 (95% confidence interval 0·89-1), P = 0·0001] in TCD classification using data from five vessels versus two vessels (dICA and MCA). Haematological variables, rather than nutritional status, may be useful markers that identify high-risk children with SCA. © 2018 John Wiley & Sons Ltd.
International Conference on Applied Sciences (ICAS2013)
NASA Astrophysics Data System (ADS)
Lemle, Ludovic Dan; Jiang, Yiwen
2014-03-01
The International Conference on Applied Sciences (ICAS2013) took place in Wuhan, P R China from 26-27 October 2013 at the Military Economics Academy. The conference is regularly organized, alternately in Romania and in P R China, by ''Politehnica'' University of Timişoara, Romania, and Military Economics Academy of Wuhan, P R China, with the aim to serve as a platform for the exchange of information between various areas of applied sciences, and to promote the communication between the scientists of different nations, countries and continents. The conference has been organized for the first time in 15-16 June 2012 at the Engineering Faculty of Hunedoara, Romania. The topics of the conference covered a comprehensive spectrum of issues: Economical sciences Engineering sciences Fundamental sciences Medical sciences The conference gathered qualified researchers whose expertise can be used to develop new engineering knowledge that has applicability potential in economics, defense, medicine, etc. The number of registered participants was nearly 90 from 5 countries. During the two days of the conference 4 invited and 36 oral talks were delivered. A few of the speakers deserve a special mention: Mircea Octavian Popoviciu, Academy of Romanian Scientist — Timişoara Branch, Correlations between mechanical properties and cavitation erosion resistance for stainless steels with 12% chromium and variable contents of nickel; Carmen Eleonora Hărău, ''Politehnica'' University of Timişoara, SWOT analysis of Romania's integration in EU; Ding Hui, Military Economics Academy of Wuhan, Design and engineering analysis of material procurement mobile operation platform; Serban Rosu, University of Medicine and Pharmacy ''Victor Babeş'' Timişoara, Cervical and facial infections — a real life threat, among others. Based on the work presented at the conference, 14 selected papers are included in this volume of IOP Conference Series: Materials Science and Engineering. These papers
Reproducibility and sensitivity of scanning laser Doppler flowmetry during graded changes in PO2
Strenn, K.; Menapace, R.; Rainer, G.; Findl, O.; Wolzt, M.; Schmetterer, L.
1997-01-01
AIMS/BACKGROUND—Recently a commercially available scanning laser Doppler flowmeter has been produced, which provides two dimensional maps of the retinal perfusion. The aim of the present study was to investigate the reproducibility and the sensitivity of these measurements. METHODS—16 healthy subjects were randomised to inhale different gas mixtures of oxygen and nitrogen in a double blind crossover study. The following gas mixtures of oxygen and nitrogen were administered: 100% oxygen + 0% nitrogen, 80% oxygen + 20% nitrogen, 60% oxygen + 40% nitrogen, 40% oxygen + 60% nitrogen, 30% oxygen + 70% nitrogen, 20% oxygen + 80% nitrogen, 15% oxygen + 85% nitrogen, and 10% oxygen + 90% nitrogen. Retinal haemodynamic variables and systemic haemodynamics were measured during all inhalation periods. Recordings under resting conditions were performed three times to calculate intraclass coefficients. RESULTS—In two subjects we did not obtain technically adequate results. A dose dependent change in retinal blood flow during graded oxygen breathing was observed (p < 0.001). During 100% oxygen breathing blood flow decrease was between 29% and 33%, whereas blood flow increase was between 28% and 33% during inhalation of 10% oxygen + 90% nitrogen. CONCLUSIONS—Scanning laser Doppler flowmetry has an acceptable reproducibility and is appropriate for description of the effect of graded changes in PO2 on retinal haemodynamics. The main problems with the system are the large zero offset, the fixation during retinal scanning, and the neglect of blood flow changes during the cardiac cycle. PMID:9227199
Ghori, Ahmer K; Chung, Kevin C
2007-12-01
The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.
Pasha, Evan P; Tarumi, Takashi; Haley, Andreana P; Tanaka, Hirofumi
2017-11-30
We determined if transcranial color-coded Doppler derived hemodynamics are associated with MRI-based cerebral blood flow (CBF) in regions clinically important to dementia in healthy middle-aged adults. In 30 subjects (18m/12f; age = 52 ± 1 years), blood flow velocity (BFV) and cerebrovascular conductance (CVC) were measured with transcranial color-coded Doppler (TCCD) at the middle cerebral artery (MCA) and cerebral blood flow (CBF) was assessed with arterial spin labeled perfusion MRI. BFV and CVC were associated with hippocampus (r = 0.58 and r = 0.61, both p < 0.01) and occipitoparietal (r = 0.50 and r = 0.58, both p < 0.01) CBF. CVC was further associated with posterior cingulate CBF (r = 0.58 p < 0.01). Independent of age and sex, BFV and CVC were associated with hippocampus (r = 0.59 and r = 0.55, both p < 0.003) and occipitoparietal (r = 0.50 and r = 0.57, both p < 0.01) CBF. CVC was independently associated with posterior cingulate CBF (r = 0.38, p = 0.049). TCCD-measured BFV and CVC of the MCA are indicators of cerebral perfusion to clinically valuable brain regions in healthy middle-aged adults. TCCD may not be a good indicator of blood flow to cerebral white matter.
Noncoherent Doppler tracking: first flight results
NASA Astrophysics Data System (ADS)
DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.
2005-01-01
Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.
Transcranial power M-mode Doppler ultrasound for diagnosis of patent foramen ovale
NASA Astrophysics Data System (ADS)
Moehring, Mark; Spencer, Merrill
2005-04-01
Patent foramen ovale (PFO) is a right-to-left shunt (RLS) which communicates blood from the right to left atrium of the heart. PFO has been associated with stroke and, more recently, with migraine headache. Diagnosis of RLS can be accomplished effectively with transcranial power M-mode Doppler ultrasound (PMD). PMD is a modality which can be performed without the sedation required by the more invasive diagnostic technique using transesophageal echocardiography. PMD for this application consists of 2 MHz pulse Doppler ultrasound with placement of sample gates at 2 mm intervals along the single-transducer beam axis, and 8 kHz pulse repetition rate (PMD100M, Spencer Technologies). Doppler power versus depth is constructed every 4ms, using 33 sample gates. Bubble microemboli injected in the venous system and moving across a PFO present as high intensity tracks on a PMD image, as emboli transit from the heart to the brain and through the observed cerebral vasculature. Use of PMD in this context has been reported in the clinical literature [M. P. Spencer, M. A. Moehring, J. Jesurum et al, J. Neuroimaging 14, 342-349 (2004)]. This talk surveys the basic technical features of PMD for sensing PFO-related showers of bubble microemboli, and how these features provide clues to the severity of PFO.
MEXnICA, Mexican group in the MPD-NICA experiment at JINR
NASA Astrophysics Data System (ADS)
Rodríguez Cahuantzi, M.;
2017-10-01
The Nuclotron Ion Collider fAcility (NICA) accelerator complex is currently under construction at the Joint Institute for Nuclear Research (JINR) laboratory located in the city of Dubna in the Russian Federation. The main goal of NICA is to collide heavy ion nuclei to study the properties of the phase diagram of strongly interacting matter at high baryon density. In this accelerator complex, two big particle detectors are planned to be installed: Spin Physics Detector (SPD) and Multi-Purpose Detector (MPD). At the design luminosity, the event rate in the MPD interaction region is about 6 kHz; the total charged particle multiplicity would exceeds 1000 in the most central Au+Au collisions at \\sqrt{{sNN}} = 11 {{GeV}}. Since the middle of 2016 a group of researchers and students from Mexican institutions was formed (MEXnICA). The main goal of the MEXnICA group is to collaborate in the experimental efforts of MPD-NICA proposing a BEam-BEam counter detector which we called BEBE. In this written general aspects of MPD-NICA detector and BEBE are discussed. This material was shown in a contributed talk given at the XXXI Annual Meeting of the Mexican Division of Particles and Fields held in the Physics Department of CINVESTAV located in Mexico City during the last week of May 2017.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banic, A.; Kouris, K.; Lewis, D.H.
1990-10-01
The aim of the study was experimentally to evaluate the capability and reliability of laser Doppler flowmetry (LDF) in conditions of circulatory deficiency, by correlating it to flow-related parameters measured by a radionuclide-imaging technique and using 99m-Tc red blood cells (RBCs). For this purpose, a pedicle island flap in the sheep was used, with well-perfused proximal parts and with evident stasis in the distal third of the flap. No correlation was found between results obtained with the two techniques. In regions with evident stasis, falsely high LDF readings were recorded. This may be due to a back-and-forth motion of themore » RBCs under the probe, rather than to true flow. It was concluded that, while LDF seems reliable in detecting complete arterial occlusion, it is unreliable in predicting either complete venous occlusion or partial obstruction of the flow to and from the flap. Clinical use for this purpose cannot be recommended.« less
Twelve-hour reproducibility of retinal and optic nerve blood flow parameters in healthy individuals.
Luksch, Alexandra; Lasta, Michael; Polak, Kaija; Fuchsjäger-Mayrl, Gabriele; Polska, Elzbieta; Garhöfer, Gerhard; Schmetterer, Leopold
2009-11-01
The aim of the present study was to investigate the reproducibility and potential diurnal variation of optic nerve head and retinal blood flow parameters in healthy individuals over a period of 12 hr. We measured optic nerve head and retinal blood flow parameters in 16 healthy male non-smoking individuals at five time-points during the day (08:00, 11:00, 14:00, 17:00 and 20:00 hr). Outcome parameters were perimacular white blood cell flux (as assessed with the blue field entoptic technique), blood velocities in retinal veins (as assessed with bi-directional laser Doppler velocimetry), retinal arterial and venous diameters (as assessed with the retinal vessel analyser), optic nerve head blood flow, volume and velocity (as assessed with single point and scanning laser Doppler flowmetry) and blood velocities in the central retinal artery (as assessed with colour Doppler imaging). The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. No diurnal variation in optic nerve head or retinal blood flow was observed with any of the techniques employed. Coefficients of variation were between 1.6% and 18.5% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 3.7% to 78.2%. Our data indicate that in healthy individuals the selected techniques provide adequate reproducibility to be used in clinical studies. However, in patients with eye diseases and reduced vision the reproducibility may be considerably worse.
Digital Doppler measurement with spacecraft
NASA Technical Reports Server (NTRS)
Kinman, Peter W.; Hinedi, Sami M.; Labelle, Remi C.; Bevan, Roland P.; Del Castillo, Hector M.; Chong, Dwayne C.
1991-01-01
Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.
Color Doppler sonography and angioscintigraphy in hepatic Hodgkin’s lymphoma
Stojković, Mirjana V; Artiko, Vera M; Radoman, Irena B; Knežević, Slavko J; Lukić, Snezana M; Kerkez, Mirko D; Lekić, Nebojsa S; Antić, Andrija A; Žuvela, Marinko M; Ranković, Vitomir I; Petrović, Milorad N; Šobić, Dragana P; Obradović, Vladimir B
2009-01-01
AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin’s hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin’s lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. RESULTS: In the majority of patients, hepatomegaly was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P > 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P < 0.01). HPI was significantly lower in patients with lymphomas than in controls (P < 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin’s hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions. PMID:19598303
ICA-Based Imagined Conceptual Words Classification on EEG Signals.
Imani, Ehsan; Pourmohammad, Ali; Bagheri, Mahsa; Mobasheri, Vida
2017-01-01
Independent component analysis (ICA) has been used for detecting and removing the eye artifacts conventionally. However, in this research, it was used not only for detecting the eye artifacts, but also for detecting the brain-produced signals of two conceptual danger and information category words. In this cross-sectional research, electroencephalography (EEG) signals were recorded using Micromed and 19-channel helmet devices in unipolar mode, wherein Cz electrode was selected as the reference electrode. In the first part of this research, the statistical community test case included four men and four women, who were 25-30 years old. In the designed task, three groups of traffic signs were considered, in which two groups referred to the concept of danger, and the third one referred to the concept of information. In the second part, the three volunteers, two men and one woman, who had the best results, were chosen from among eight participants. In the second designed task, direction arrows (up, down, left, and right) were used. For the 2/8 volunteers in the rest times, very high-power alpha waves were observed from the back of the head; however, in the thinking times, they were different. According to this result, alpha waves for changing the task from thinking to rest condition took at least 3 s for the two volunteers, and it was at most 5 s until they went to the absolute rest condition. For the 7/8 volunteers, the danger and information signals were well classified; these differences for the 5/8 volunteers were observed in the right hemisphere, and, for the other three volunteers, the differences were observed in the left hemisphere. For the second task, simulations showed that the best classification accuracies resulted when the time window was 2.5 s. In addition, it also showed that the features of the autoregressive (AR)-15 model coefficients were the best choices for extracting the features. For all the states of neural network except hardlim discriminator
Park, Jinse; Kim, Hee-Tae; Park, Kang Min; Ha, Sam Yeol; Kim, Sung Eun; Shin, Kyong Jin; Kim, Si Eun; Jang, Wooyoung; Kim, Ji Sun; Youn, Jinyoung; Oh, Engsoek; Park, Suyeon
2017-07-08
Orthostatic hypotension (OH) is controversially regarded as the cause of orthostatic dizziness in Parkinson's disease (PD). We sought to evaluate whether cerebral autoregulation is an alternative cause for orthostatic dizziness in PD patients, using transcranial Doppler monitoring during head-up tilting. Forty-five PD patients with dizziness, 13 PD patients without dizziness, and 10 age-matched healthy controls were enrolled. Participants were divided into the following four groups: patients with dizziness and OH (group 1, n = 22), patients with dizziness but no OH (n = 23, group 2), patients without dizziness (n = 11, group 3), and age-matched healthy controls (n = 10, group 4). All participants underwent transcranial Doppler and blood pressure monitoring for 10 minutes during the head-up tilt test. Changes in the cerebral blood flow velocity (CBFV) in the middle cerebral artery and the mean blood pressure (mBP) within 3 minutes after head-up tilting were compared between groups. Group 1 showed a significantly higher change in mBP (-16.3 ± 10.8 mmHg) than groups 2 (-2.6 ± 4.9), 3 (-2.2 ± 3.6), or 4 (1.8 ± 6.0) (p < 0.001). However, groups 3 (4.6 ± 3.0 cm/s) and 4 (-4.2 ± 2.5) showed a significantly smaller change in CBFV than groups 1 (-9.0 ± 4.2) and 2 (-8.1 ± 5.1) (p < 0.01). Our results suggest that cerebral hypoperfusion contributes to dizziness in PD patients despite a lack of OH. Transcranial Doppler monitoring during head-up tilting may be a useful tool for evaluating dizziness in PD patients with or without OH. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:337-342, 2017. © 2017 Wiley Periodicals, Inc.
Figueiredo, Agnes Marie Sá; Ferreira, Fabienne Antunes; Beltrame, Cristiana Ossaille; Côrtes, Marina Farrel
2017-09-01
Staphylococcus aureus biofilms represent a unique micro-environment that directly contribute to the bacterial fitness within hospital settings. The accumulation of this structure on implanted medical devices has frequently caused the development of persistent and chronic S. aureus-associated infections, which represent an important social and economic burden worldwide. ica-independent biofilms are composed of an assortment of bacterial products and modulated by a multifaceted and overlapping regulatory network; therefore, biofilm composition can vary among S. aureus strains. In the microniches formed by biofilms-produced by a number of bacterial species and composed by different structural components-drug refractory cell subpopulations with distinct physiological characteristics can emerge and result in therapeutic failures in patients with recalcitrant bacterial infections. In this review, we highlight the importance of biofilms in the development of persistence and chronicity in some S. aureus diseases, the main molecules associated with ica-independent biofilm development and the regulatory mechanisms that modulate ica-independent biofilm production, accumulation, and dispersion.
Neves, R C; Stokol, T; Bach, K D; McArt, J A A
2018-02-01
The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from
Provence, Aaron; Malysz, John
2015-01-01
The physiologic roles of voltage-gated KV7 channel subtypes (KV7.1–KV7.5) in detrusor smooth muscle (DSM) are poorly understood. Here, we sought to elucidate the functional roles of KV7.2/KV7.3 channels in guinea pig DSM excitability and contractility using the novel KV7.2/KV7.3 channel activator ICA-069673 [N-(2-chloro-5-pyrimidinyl)-3,4-difluorobenzamide]. We employed a multilevel experimental approach using Western blot analysis, immunocytochemistry, isometric DSM tension recordings, fluorescence Ca2+ imaging, and perforated whole-cell patch-clamp electrophysiology. Western blot experiments revealed the protein expression of KV7.2 and KV7.3 channel subunits in DSM tissue. In isolated DSM cells, immunocytochemistry with confocal microscopy further confirmed protein expression for KV7.2 and KV7.3 channel subunits, where they localize within the vicinity of the cell membrane. ICA-069673 inhibited spontaneous phasic, pharmacologically induced, and nerve-evoked contractions in DSM isolated strips in a concentration-dependent manner. The inhibitory effects of ICA-069673 on DSM spontaneous phasic and tonic contractions were abolished in the presence of the KV7 channel inhibitor XE991 [10,10-bis(4-pyridinylmethyl)-9(10H)-anthracenone dihydrochloride]. Under conditions of elevated extracellular K+ (60 mM), the effects of ICA-069673 on DSM tonic contractions were significantly attenuated. ICA-069673 decreased the global intracellular Ca2+ concentration in DSM cells, an effect blocked by the L-type Ca2+ channel inhibitor nifedipine. ICA-069673 hyperpolarized the membrane potential and inhibited spontaneous action potentials of isolated DSM cells, effects that were blocked in the presence of XE991. In conclusion, using the novel KV7.2/KV7.3 channel activator ICA-069673, this study provides strong evidence for a critical role for the KV7.2- and KV7.3-containing channels in DSM function at both cellular and tissue levels. PMID:26087697
Provence, Aaron; Malysz, John; Petkov, Georgi V
2015-09-01
The physiologic roles of voltage-gated KV7 channel subtypes (KV7.1-KV7.5) in detrusor smooth muscle (DSM) are poorly understood. Here, we sought to elucidate the functional roles of KV7.2/KV7.3 channels in guinea pig DSM excitability and contractility using the novel KV7.2/KV7.3 channel activator ICA-069673 [N-(2-chloro-5-pyrimidinyl)-3,4-difluorobenzamide]. We employed a multilevel experimental approach using Western blot analysis, immunocytochemistry, isometric DSM tension recordings, fluorescence Ca(2+) imaging, and perforated whole-cell patch-clamp electrophysiology. Western blot experiments revealed the protein expression of KV7.2 and KV7.3 channel subunits in DSM tissue. In isolated DSM cells, immunocytochemistry with confocal microscopy further confirmed protein expression for KV7.2 and KV7.3 channel subunits, where they localize within the vicinity of the cell membrane. ICA-069673 inhibited spontaneous phasic, pharmacologically induced, and nerve-evoked contractions in DSM isolated strips in a concentration-dependent manner. The inhibitory effects of ICA-069673 on DSM spontaneous phasic and tonic contractions were abolished in the presence of the KV7 channel inhibitor XE991 [10,10-bis(4-pyridinylmethyl)-9(10H)-anthracenone dihydrochloride]. Under conditions of elevated extracellular K(+) (60 mM), the effects of ICA-069673 on DSM tonic contractions were significantly attenuated. ICA-069673 decreased the global intracellular Ca(2+) concentration in DSM cells, an effect blocked by the L-type Ca(2+) channel inhibitor nifedipine. ICA-069673 hyperpolarized the membrane potential and inhibited spontaneous action potentials of isolated DSM cells, effects that were blocked in the presence of XE991. In conclusion, using the novel KV7.2/KV7.3 channel activator ICA-069673, this study provides strong evidence for a critical role for the KV7.2- and KV7.3-containing channels in DSM function at both cellular and tissue levels. Copyright © 2015 by The American Society for
Zherebtsov, Evgeny A; Zherebtsova, Angelina I; Doronin, Alexander; Dunaev, Andrey V; Podmasteryev, Konstantin V; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
NASA Astrophysics Data System (ADS)
Zherebtsov, Evgeny A.; Zherebtsova, Angelina I.; Doronin, Alexander; Dunaev, Andrey V.; Podmasteryev, Konstantin V.; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
De-Dopplerization of Acoustic Measurements
2017-08-10
band energy obtained from fractional octave band digital filters generates a de-Dopplerized spectrum without complex resampling algorithms. An...energy obtained from fractional octave band digital filters generates a de-Dopplerized spectrum without complex resampling algorithms. An equation...fractional octave representation and smearing that occurs within the spectrum11, digital filtering techniques were not considered by these earlier
Ultrasonic Blood Flow Measurement in Haemodialysis
Sampson, D.; Papadimitriou, M.; Kulatilake, A. E.
1970-01-01
A 5-megacycle Doppler flow meter, calibrated in-vitro, was found to give a linear response to blood flow in the ranges commonly encountered in haemodialysis. With this, blood flow through artificial kidneys could be measured simply and with a clinically acceptable error. The method is safe, as blood lines do not have to be punctured or disconnected and hence there is no risk of introducing infection. Besides its value as a research tool the flow meter is useful in evaluating new artificial kidneys. Suitably modified it could form the basis of an arterial flow alarm system. PMID:5416812
Analysis and prediction of Doppler noise during solar conjunctions
NASA Technical Reports Server (NTRS)
Berman, A. L.; Rockwell, S. T.
1975-01-01
The results of a study of Doppler data noise during solar conjunctions were presented. During the first half of 1975, a sizeable data base of Doppler data noise (estimates) for the Pioneer 10, Pioneer 11, and Helios 1 solar conjunctions was accumulated. To analyze this data, certain physical assumptions are made, leading to the development of a geometric parameter ("ISI") which correlates strongly with Doppler data noise under varying sun-earth-spacecraft geometries. Doppler noise models are then constructed from this parameter, resulting in the newfound ability to predict Doppler data noise during solar conjunctions, and hence to additionally be in a position to validate Doppler data acquired during solar conjunctions.
Using a laser-Doppler flowmetry to measure pulsatile microcirculation on the kidney in rats
NASA Astrophysics Data System (ADS)
Jan, Ming-Yie; Chao, Pin-Tsun; Hsu, Tse-Lin; Wang, Yuh-Yin L.; Wang, Wei-Kung
2001-10-01
Although Laser Doppler flowmetery (LDF) been extensively used in measurement of microvascular blood flow of different tissues. However, due to some physiological vibrations, fast oscillations of the renal cortical flux (RCF) are hard to be measured. In the study, a commercial 3mW 780nm Laser Doppler flowmetery, with a single fiber and a de-vibration holder, was used to measure the pulsatile RCF in rats. Considering the fast response due to the heart rate of rats, the time constant (TC) was set to 0.05 second and thus the frequency response is up to 20Hz. Furthermore, a calibration standard and a static blood sample were also measured as the references without the pulsatile driving force. In order not to perturb the RCF with tiny momentum, the applying force that the fiber exerted on the renal surface was controlled below 100 dyne. To enhance the signal to noise ratio (SNR), an averaged periodogram was used to estimate the frequency components of the pulsatile microcirculation. It is found that the dominating fast oscillation of RCF is pulsatile and its harmonic components are directly correlated with those of the heartbeat (correlation coefficient =0.999, P<0.001, n=17). The result shows that, in the kidney, the pulsatile RCF is the dominating component of microcirculation oscillation and driven by the fast propagating blood pressure. This technique could be further utilized to analyze the pharmacological effect and hemodynamic parameters on renal function.
A transcranial Doppler sonography study of shoot/don't-shoot responding.
Schultz, Natasha B; Matthews, Gerald; Warm, Joel S; Washburn, David A
2009-08-01
The purpose of this study was to examine the relationship between changes in cerebral blood-flow velocity and performance on a speeded shoot/don't-shoot task. Brain activity as indicated by cerebral blood-flow velocity (hemovelocity) was recorded using the transcranial Doppler ultrasonography. A shoot/don't-shoot decision-making task presented participants with threat/nonthreat stimuli in the form of bull's-eye images of various colors. Participants were required to shoot threat targets using a laser-modified handgun. Results support a vigilance decrement in both the performance measures and hemovelocity. Performance, as measured by reaction time, number of hits, and marksmanship, decreased across the length of the vigil. Hemovelocity slowed across the left and right hemispheres as the task progressed, and hemovelocity was slower in the right hemisphere than in the left hemisphere.
NASA Astrophysics Data System (ADS)
Jiang, Yan; Harrison, Tyler; Forbrich, Alex; Zemp, Roger J.
2011-03-01
The metabolic rate of oxygen consumption (MRO2) quantifies tissue metabolism, which is important for diagnosis of many diseases. For a single vessel model, the MRO2 can be estimated in terms of the mean flow velocity, vessel crosssectional area, total concentration of hemoglobin (CHB), and the difference between the oxygen saturation (sO2) of blood flowing into and out of the tissue region. In this work, we would like to show the feasibility to estimate MRO2 with our combined photoacoustic and high-frequency ultrasound imaging system. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-field laser illumination optics. A pulse-sequencer enables ultrasonic and laser pulses to be interlaced so that photoacoustic and Doppler ultrasound images are co-registered. Since the mean flow velocity can be measured by color Doppler ultrasound, the vessel cross-sectional area can be measured by power Doppler or photoacoustic imaging, and multi-wavelength photoacoustic methods can be used to estimate sO2 and CHB, all of these parameters necessary for MRO2 estimation can be provided by our system. Experiments have been performed on flow phantoms to generate co-registered color Doppler and photoacoustic images. To verify the sO2 estimation, two ink samples (red and blue) were mixed in various concentration ratios to mimic different levels of sO2, and the result shows a good match between the calculated concentration ratios and actual values.
Continuous cardiac output measurement - Aspects of Doppler frequency analysis
NASA Technical Reports Server (NTRS)
Mackay, R. S.; Hechtman, H. B.
1975-01-01
From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.
Skin microcirculation and vasopressin infusion: a laser Doppler study
Bernard, Francis; Vinet, Alain; Verdant, Colin
2006-01-01
Use of arginine vasopressin in the management of refractory vasodilatory shock has been associated with development of ischaemic skin lesions. Because of the increasing popularity of arginine vasopressin, it is important to evaluate its effects on microcirculatory blood flow. Such studies are crucial if we are to appreciate the microcirculatory consequences of our various resuscitation strategies. However, methodological issues must always be considered because they can significantly influence interpretation of the results. Some aspects of use of laser Doppler to evaluate the microcirculation are reviewed within the context of recent findings presented by Luckner and coworkers in this issue of Critical Care. PMID:16594988
Wilkins, G T; Gillam, L D; Kritzer, G L; Levine, R A; Palacios, I F; Weyman, A E
1986-10-01
For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore recorded simultaneous continuous-wave Doppler flow profiles and transvalvular manometric gradients in 12 catheterized patients in whom all atrial and ventricular pressures were directly measured (transseptal left atrial catheterization and transthoracic ventricular puncture were performed where necessary). A total of 13 prostheses were studied: 11 mitral (seven porcine, three Starr-Edwards, and one Björk-Shiley) and two tricuspid (one porcine and one Björk-Shiley). The Doppler-determined mean gradient was calculated as the mean of the instantaneous gradients (delta P = 4V2) at 10 msec intervals throughout diastole. The correlation of simultaneous Doppler (DMG) and manometric mean gradients (MG) for the whole group (n = 13) demonstrated a highly significant relationship (MG = 1.07 DMG + 0.28; r = .96, p = .0001). The correlation was equally good for porcine valves alone (n = 8) (MG = 1.06 DMG + 0.55; r = .96, p = .001) and for mechanical valves alone (n = 5) (MG = 1.06 DMG - 0.04; r = .93, p = .02). In a subset of patients without regurgitation (n = 8), prosthetic valve areas were estimated by two Doppler methods originally described by Holen and Hatle, as well as by the invasive Gorlin method. As expected from theoretical considerations, a close correlation was not demonstrated between results of the Gorlin method and those of either Hatle's Doppler method (r = .65, fp = NS) or Holen's method (r = .14, p = NS). Comparison of the results of the two Doppler methods yielded a somewhat closer correlation (r = .73, p less than or equal to .05). These results suggest that in
Inverse Doppler Effects in Broadband Acoustic Metamaterials
Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.
2016-01-01
The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe. PMID:27578317
Inverse Doppler Effects in Broadband Acoustic Metamaterials
NASA Astrophysics Data System (ADS)
Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.
2016-08-01
The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.
NASA Astrophysics Data System (ADS)
Huang, Yong; Tong, Dedi; Zhu, Shan; Wu, Lehao; Ibrahim, Zuhaib; Lee, WP Andrew; Brandacher, Gerald; Kang, Jin U.
2014-03-01
Vascular and microvascular anastomosis are critical components of reconstructive microsurgery, vascular surgery and transplant surgery. Imaging modality that provides immediate, real-time in-depth view and 3D structure and flow information of the surgical site can be a great valuable tool for the surgeon to evaluate surgical outcome following both conventional and innovative anastomosis techniques, thus potentially increase the surgical success rate. Microvascular anastomosis for vessels with outer diameter smaller than 1.0 mm is extremely challenging and effective evaluation of the outcome is very difficult if not impossible using computed tomography (CT) angiograms, magnetic resonance (MR) angiograms and ultrasound Doppler. Optical coherence tomography (OCT) is a non-invasive high-resolution (micron level), high-speed, 3D imaging modality that has been adopted widely in biomedical and clinical applications. Phaseresolved Doppler OCT that explores the phase information of OCT signals has been shown to be capable of characterizing dynamic blood flow clinically. In this work, we explore the capability of Fourier domain Doppler OCT as an evaluation tool to detect commonly encountered post-operative complications that will cause surgical failure and to confirm positive result with surgeon's observation. Both suture and cuff based techniques were evaluated on the femoral artery and vein in the rodent model.
Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis
Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami
2013-01-01
AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754
NASA Astrophysics Data System (ADS)
Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.
2018-03-01
We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys, however, we show that the Doppler term must be included. The effect of these terms is dominated by the magnification due to relativistic aberration effects and the slope of the galaxy redshift distribution and it generally mimics the effect of the local type primordial non-Gaussianity with the effective nonlinearity parameter fNLeff of a few; we show that this would affect forecasts on measurements of fNL at low-redshift. Our results show that a survey at low redshift with large number density over a wide area of the sky could detect the Doppler term with a signal-to-noise ratio of ∼ 1 - 20, depending on survey specifications.
Micro-Doppler analysis of multiple frequency continuous wave radar signatures
NASA Astrophysics Data System (ADS)
Anderson, Michael G.; Rogers, Robert L.
2007-04-01
Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.
NASA Astrophysics Data System (ADS)
Glock, N.; Liebetrau, V.; Eisenhauer, A.
2014-12-01
Tropical oxygen minimum zones (OMZs) are most important areas of oxygen depletion in today´s oceans and nutrient cycling in these regions has a large socio-economic impact because they account for about 17% of the global commercial fish catches(1). Possibly increasing magnitude and area of oxygen depletion in these regions, might endanger rich pelagic fish habitats in the future threatening the global marine food supply. By the use of a quantitative redox proxy in OMZs, reconstruction of the temporal variation in OMZ extension eventually providing information about past and future changes in oxygenation and the anthropogenic role in the recent trend of expanding OMZs(2). Recent work has shown that iodine/calcium (I/Ca) ratios in marine carbonates are a promising proxy for ambient oxygen concentration(3). Our study explores the correlation of I/Ca ratios in four benthic foraminiferal species (three calcitic, one aragonitic) from the Peruvian OMZ to bottom water oxygen concentrations ([O2]BW) and evaluates foraminiferal I/Ca ratios as a possible redox proxy for the ambient water masses. Our results show that all species have a positive trend in the I/Ca ratios as a function of [O2]BW. Only for the aragonitic species Hoeglundina elegans this trend is not significant. The highest significance has been found for Uvigerina striata (I/Ca = 0.032(±0.004).[O2]BW + 0.29(±0.03), R² = 0.61, F = 75, P < 0.0001). Although I/Ca ratios in benthic foraminifera appear to be a robust redox proxy there are some methodical issues which have to be considered. These "pitfalls" include: (i) the volatility of iodine in acidic solutions, (ii) a species dependency of the I/Ca-[O2]BW relationship which is either related to a strong vital effect or toa species dependency on the calcification depth within sediment, and (iii) the inter-test variability of I/Ca between different specimens from the same species and habitat. (1): FAO FishStat: Fisheries and aquaculture software. In: FAO
[Venous Doppler color echography: importance and inconveniences].
Laroche, J P; Dauzat, M; Muller, G; Janbon, C
1993-01-01
Color Doppler is a technique which performs a real-time opacification of the vascular system with blue indicating reverse flow and red indicating forward flow (directional color coding). In venous pathology, the use of color Doppler improves significantly the anatomical evaluation of the inferior vena cava, the iliac vein, the deep femoral vein, and the sural system. Color Doppler facilitates the study of deep venous thrombosis (providing useful information to differentiate ancient from most recent thrombus) and also the study of post-thrombotic conditions (assessment of reverse flow, repermeation phenomena). Finally, color Doppler produces a better insight for the study of varicose veins, especially with regard to mapping, identification of communicante veins, and study of the external saphenous vein.
Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?
Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V
2015-12-01
Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.
Velocity measurement by vibro-acoustic Doppler.
Nabavizadeh, Alireza; Urban, Matthew W; Kinnick, Randall R; Fatemi, Mostafa
2012-04-01
We describe the theoretical principles of a new Doppler method, which uses the acoustic response of a moving object to a highly localized dynamic radiation force of the ultrasound field to calculate the velocity of the moving object according to Doppler frequency shift. This method, named vibro-acoustic Doppler (VAD), employs two ultrasound beams separated by a slight frequency difference, Δf, transmitting in an X-focal configuration. Both ultrasound beams experience a frequency shift because of the moving objects and their interaction at the joint focal zone produces an acoustic frequency shift occurring around the low-frequency (Δf) acoustic emission signal. The acoustic emission field resulting from the vibration of the moving object is detected and used to calculate its velocity. We report the formula that describes the relation between Doppler frequency shift of the emitted acoustic field and the velocity of the moving object. To verify the theory, we used a string phantom. We also tested our method by measuring fluid velocity in a tube. The results show that the error calculated for both string and fluid velocities is less than 9.1%. Our theory shows that in the worst case, the error is 0.54% for a 25° angle variation for the VAD method compared with an error of -82.6% for a 25° angle variation for a conventional continuous wave Doppler method. An advantage of this method is that, unlike conventional Doppler, it is not sensitive to angles between the ultrasound beams and direction of motion.
Non-invasive determination of instantaneous brachial blood flow using the oscillometric method.
Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan
2009-08-01
The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r = 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.
Effect of ovarian endometrioma on uterine and ovarian blood flow in infertile women.
El-Mazny, Akmal; Kamel, Ahmed; Ramadan, Wafaa; Gad-Allah, Sherine; Abdelaziz, Suzy; Hussein, Ahmed M
2016-01-01
Angiogenesis has been found to be among the most important factors in the pathogenesis of endometriosis. The formation of new blood vessels is critical for the survival of newly implanted endometriotic foci. The use of 3-D power Doppler allows for the demonstration of the dynamic vascular changes that occur during the process of in vitro fertilization (IVF). We aimed to evaluate the effect of ovarian endometrioma on uterine and ovarian blood flow in infertile women. In a case-control study at a university teaching hospital, 138 women with unilateral ovarian endometrioma scheduled for IVF were compared to 138 women with male-factor or unexplained infertility. In the mid-luteal (peri-implantation) phase of the cycle, endometrial thickness, uterine and ovarian artery pulsatility index and resistance index, endometrial and ovarian volume, 3-D power Doppler vascularization index (VI), flow index (FI), and vascularization FI (VFI) values were measured in both groups. There were no significant differences ( P >0.05) in endometrial thickness, uterine ovarian artery pulsatility index and resistance index, endometrial and ovarian volume, or VI, FI, and VFI between the two groups. Furthermore, the endometrial and ovarian Doppler indices were not influenced by endometrioma size. No significant differences were observed in the ovarian Doppler indices between endometrioma-containing ovaries and contralateral ovaries. Ovarian endometrioma is not associated with impaired endometrial and ovarian blood flows in infertile women scheduled for IVF, and it is not likely to affect endometrial receptivity or ovarian function through a vascular mechanism.
Escudero, D; Otero, J; Quindós, B; Viña, L
2015-05-01
Transcranial Doppler ultrasound is able to demonstrate cerebral circulatory arrest associated to brain death, being especially useful in sedated patients, or in those in which complete neurological exploration is not possible. Transcranial Doppler ulstrasound is a portable, noninvasive and high-availability technique. Among its limitations, mention must be made of the absence of acoustic windows and false-negative cases. In patients clinically diagnosed with brain death, with open skulls or with anoxia as the cause of death, cerebral blood flow can be observed by ultrasound, since cerebral circulatory arrest is not always synchronized to the clinical diagnosis. The diagnostic rate is therefore time-dependent, and this fact that must be recognized in order to avoid delays in death certification. Despite its limitations, transcranial Doppler ulstrasound helps solve common diagnostic problems, avoids the unnecessary consumption of resources, and can optimize organ harvesting for transplantation. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
Mathematical Models for Doppler Measurements
NASA Technical Reports Server (NTRS)
Lear, William M.
1987-01-01
Error analysis increases precision of navigation. Report presents improved mathematical models of analysis of Doppler measurements and measurement errors of spacecraft navigation. To take advantage of potential navigational accuracy of Doppler measurements, precise equations relate measured cycle count to position and velocity. Drifts and random variations in transmitter and receiver oscillator frequencies taken into account. Mathematical models also adapted to aircraft navigation, radar, sonar, lidar, and interferometry.
Rezk, Mohamed Abd-Allah; Shawky, Mohamed
2016-01-01
To assess the effectiveness of grey-scale and colour Doppler ultrasound (US) versus magnetic resonance imaging (MRI) for the prenatal diagnosis of placenta accreta. A prospective observational study including a total of 74 patients with placenta previa and previous uterine scar (n = 74). Grey-scale and colour Doppler US was done followed by MRI by different observers to diagnose adherent placenta. Test validity of US and MRI were calculated. Maternal morbidity and mortality were also assessed. A total of 53 patients confirmed to have placenta accreta at operation. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US was 94.34, 91.67, 96.15 and 88% compared to 96.08, 87.50, 94.23 and 91.3% for MRI, respectively. The most relevant US sign was turbulent blood flow by colour Doppler, while dark intra-placental band was the most sensitive MRI sign. Venous thromboembolism (1.3%), bladder injury (29.7%), ureteric injury (18.9%), postoperative fever (10.8%), admission to ICU (50%) and re-operation (31.1%). Placenta accreta can be successfully diagnosed by grey-scale and colour Doppler US. MRI would be more likely suggested for either posteriorly or laterally situated placenta previa in order to exclude placental invasion.
Weber, U; Glassford, N J; Eastwood, G M; Bellomo, R; Hilton, A K
2015-10-01
We measured carotid and brachial artery blood flow by Doppler ultrasound in 11 human volunteers, and related these to cardiac index and to each other. The median (IQR [range]) carotid arterial blood flow was 0.334 (0.223-0.381 [0.052-0.563]) l.min(-1) on the right and 0.315 (0.223-0.369 [0.061-0.690]) l.min(-1) on the left. The brachial arterial blood flow was 0.049 (0.033-0.062 [0.015-0.204]) l.min(-1) on the right and 0.039 (0.027-0.054 [0.011-0.116]) on the left. Cardiac index was 3.2 (2.8-3.5 [1.9-5.4]) l.min(-1) .m(-2) . There was a moderate to good correlation between right-and left-sided flows (brachial: ρ = 0.45; carotid: ρ = 0.567). Brachial and carotid flow had no or a negative correlation with cardiac index (right brachial: ρ = -0.145, left brachial: ρ = -0.349; right carotid: ρ = -0.376, left carotid: ρ = -0.285). In contrast to some previous studies, we found that Doppler-estimated peripheral arterial blood flows only show a weak correlation with cardiac index and cannot be used to provide non-invasive estimates of cardiac index in man. © 2015 The Association of Anaesthetists of Great Britain and Ireland.
Coherent Doppler lidar for measurements of wind fields
NASA Technical Reports Server (NTRS)
Menzies, Robert T.; Hardesty, R. Michael
1989-01-01
The signal-processing techniques for obtaining the velocity estimates and the fundamental factors that influence coherent lidar performance are considered. The similarities and distinctions between Doppler lidar and Doppler radars are discussed. The capability of coherent Doppler lidars for mapping wind fields over selected regions in the lower atmosphere and greatly enhancing the capability to visualize flow patterns in real time is discussed, and examples are given. Salient features of a concept for an earth-orbiting Doppler lidar to be launched in the late 1990s are examined.
NASA Technical Reports Server (NTRS)
Bluestein, H. B.; Doviak, R. J.; Eilts, M. D.; Mccaul, E. W.; Rabin, R.; Sundara-Rajan, A.; Zrnic, D. S.
1986-01-01
The first experiment to combine airborne Doppler Lidar and ground-based dual Doppler Radar measurements of wind to detail the lower tropospheric flows in quiescent and stormy weather was conducted in central Oklahoma during four days in June-July 1981. Data from these unique remote sensing instruments, coupled with data from conventional in-situ facilities, i.e., 500-m meteorological tower, rawinsonde, and surface based sensors, were analyzed to enhance understanding of wind, waves and turbulence. The purposes of the study were to: (1) compare winds mapped by ground-based dual Doppler radars, airborne Doppler lidar, and anemometers on a tower; (2) compare measured atmospheric boundary layer flow with flows predicted by theoretical models; (3) investigate the kinematic structure of air mass boundaries that precede the development of severe storms; and (4) study the kinematic structure of thunderstorm phenomena (downdrafts, gust fronts, etc.) that produce wind shear and turbulence hazardous to aircraft operations. The report consists of three parts: Part 1, Intercomparison of Wind Data from Airborne Lidar, Ground-Based Radars and Instrumented 444 m Tower; Part 2, The Structure of the Convective Atmospheric Boundary Layer as Revealed by Lidar and Doppler Radars; and Part 3, Doppler Lidar Observations in Thunderstorm Environments.
Kumar, Vipin; Jose, John; Jose, V Jacob
2014-01-01
62-year-old female presented with progressive dyspnea NYHA class III for six months. Echocardiography showed normal left ventricular (LV) systolic function, mild biatrial enlargement, an L wave in pulse wave Doppler at mitral inflow and in M mode echocardiography across mitral valve. Tissue Doppler imaging at medial mitral annulus showed an L' wave in mid diastole in addition to E' and A' wave. An L wave in pulse wave Doppler and M mode echocardiography represents continued pulmonary vein mid diastolic flow through the left atrium in to LV across mitral valve after early rapid filling. Presence of an L' wave in these patients associated with higher E/E' is indicative of advance diastolic dysfunction with elevated filling pressures. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Molecular filter based planar Doppler velocimetry
NASA Astrophysics Data System (ADS)
Elliott, Gregory S.; Beutner, Thomas J.
1999-11-01
Molecular filter based diagnostics are continuing to gain popularity as a research tool for investigations in areas of aerodynamics, fluid mechanics, and combustion. This class of diagnostics has gone by many terms including Filtered Rayleigh Scattering, Doppler Global Velocimetry, and Planar Doppler Velocimetry. The majority of this article reviews recent advances in Planar Doppler Velocimetry in measuring up to three velocity components over a planar region in a flowfield. The history of the development of these techniques is given with a description of typical systems, components, and levels of uncertainty in the measurement. Current trends indicate that uncertainties on the order of 1 m/s are possible with these techniques. A comprehensive review is also given on the application of Planar Doppler Velocimetry to laboratory flows, supersonic flows, and large scale subsonic wind tunnels. The article concludes with a description of future trends, which may simplify the technique, followed by a description of techniques which allow multi-property measurements (i.e. velocity, density, temperature, and pressure) simultaneously.
Adaptation of laser-Doppler flowmetry to measure cerebral blood flow in the fetal sheep.
Lan, J; Hunter, C J; Murata, T; Power, G G
2000-09-01
The purpose of this study was to devise a means to use laser-Doppler flowmetry to measure cerebral perfusion before birth. The method has not been used previously, largely because of intrauterine movement artifacts. To minimize movement artifacts, a probe holder was molded from epoxy putty to the contour of the fetal skull. A curved 18-gauge needle was embedded in the holder. At surgery, the holder, probe, and skull were fixed together with tissue glue. Residual signals were recorded after fetal death and after maternal death 1 h later. These averaged <5% of baseline flow signals, indicating minimal movement artifact. To test the usefulness of the method, cerebral flow responses were measured during moderate fetal hypoxia induced by giving the ewes approximately 10% oxygen in nitrogen to breathe. As fetal arterial PO(2) decreased from 21.1 +/- 0.5 to 10.7 +/- 0.4 Torr during a 30-min period, cerebral perfusion increased progressively to 56 +/- 8% above baseline. Perfusion then returned to baseline levels during a 30-min recovery period. These responses are quantitatively similar to those spot observations that have been recorded earlier using labeled microspheres. We conclude that cerebral perfusion can be successfully measured by using laser-Doppler flowmetry with the unanesthetized, chronically prepared fetal sheep as an experimental model. With this method, relative changes of perfusion from a small volume of the ovine fetal brain can be measured on a continuous basis, and movement artifacts can be reduced to 5% of measured flow values.
Nugent, Allison C; Luber, Bruce; Carver, Frederick W; Robinson, Stephen E; Coppola, Richard; Zarate, Carlos A
2017-02-01
Recently, independent components analysis (ICA) of resting state magnetoencephalography (MEG) recordings has revealed resting state networks (RSNs) that exhibit fluctuations of band-limited power envelopes. Most of the work in this area has concentrated on networks derived from the power envelope of beta bandpass-filtered data. Although research has demonstrated that most networks show maximal correlation in the beta band, little is known about how spatial patterns of correlations may differ across frequencies. This study analyzed MEG data from 18 healthy subjects to determine if the spatial patterns of RSNs differed between delta, theta, alpha, beta, gamma, and high gamma frequency bands. To validate our method, we focused on the sensorimotor network, which is well-characterized and robust in both MEG and functional magnetic resonance imaging (fMRI) resting state data. Synthetic aperture magnetometry (SAM) was used to project signals into anatomical source space separately in each band before a group temporal ICA was performed over all subjects and bands. This method preserved the inherent correlation structure of the data and reflected connectivity derived from single-band ICA, but also allowed identification of spatial spectral modes that are consistent across subjects. The implications of these results on our understanding of sensorimotor function are discussed, as are the potential applications of this technique. Hum Brain Mapp 38:779-791, 2017. © 2016 Wiley Periodicals, Inc. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Sousa, Francisco C A; Pessoa, Gerson T; Moura, Laecio S; Rodrigues, Renan P S; Diniz, Anaemilia N; Souza, André B; Silva, Elzivânia G; Sanches, Marina P; Silva-Filho, Osmar F; Guerra, Porfirio C; Sousa, João M; Neves, Willams C; Alves, Flávio R
2016-11-01
The use of ultrasound for pregnancy monitoring is critical for the evaluation of hemodynamic parameters essential to fetal viability. In the present study, using B-mode and Doppler ultrasound, we characterized the placenta, subplacenta, maternal, and fetal vessels during normal gestation of healthy agoutis raised in captivity. In total, 30 agoutis were obtained from the Center for the Study and Preservation of Wild Animals, Center of Agricultural Sciences, Federal University of Piauí (Núcleo de Estudos e Preservação de Animais Silvestres-NEPAS, Centro de Ciências Agrárias-CCA, Universidade Federal do Piauí-UFPI). These animals were subjected to B-mode and Doppler ultrasound examinations to evaluate their maternal and fetal hemodynamic profiles. The placenta was located in the mesometrial region and had a discoid, ellipsoid, or globular aspect. With spectral Doppler, characteristic systolic and diastolic flow was observed in the umbilical artery. This flow increased during pregnancy. A cross-sectional view revealed a goblet-shaped placenta. The uteroplacental blood flow was characterized by a marked increase in systolic peak velocity during pregnancy, the presence of a rapid deceleration ramp, and a relatively high diastolic speed. The fetal aortic vascular flow was predominantly systolic and diastolic. The caudal vena cava blood flow was characterized by a systolic peak followed by a decreased diastolic wave throughout pregnancy. In the present study, we characterized the morphologic and hemodynamic interactions of the placenta/subplacenta with maternal and fetal vessels in agoutis at 30, 45, 60, 75, and 90 days gestation using B-mode and Doppler ultrasound. We determined the approximation and separation of the blood flow values of the umbilical artery, subplacental flow, uteroplacental artery, fetal aorta, and fetal vena cava. We believe these values may contribute to an understanding of the gestational biology and aid delivery prediction in this species
Spacecraft Doppler Tracking as a Xylophone Detector
NASA Technical Reports Server (NTRS)
Tinto, Massimo
1996-01-01
We discuss spacecraft Doppler tracking in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we derive a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground. Our method provides also for reducing by several orders of magnitude, at selected Fourier components, the frequency fluctuations due to other noise sources, such as the clock on board the spacecraft or the antenna and buffeting of the probe by non-gravitational forces. In this respect spacecraft Doppler tracking can be regarded as a xylophone detector. Estimates of the sensitivities achievable by this xylophone are presented for two tests of Einstein's theory of relativity: searches for gravitational waves and measurements of the gravitational red shift. This experimental technique could be extended to other tests of the theory of relativity, and to radio science experiments that rely on high-precision Doppler measurements.
MP3 compression of Doppler ultrasound signals.
Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W
2003-01-01
The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology
Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C
2014-08-01
Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Fang, Li-Min; Lin, Min
2009-08-01
For the rapid detection of the ethanol, pH and rest sugar in red wine, infrared (IR) spectra of 44 wine samples were analyzed. The algorithm of fast independent component analysis (FastICA) was used to decompose the data of IR spectra, and their independent components and the mixing matrix were obtained. Then, the ICA-NNR calibration model with three-level artificial neural network (ANN) structure was built by using back-propagation (BP) algorithm. The models were used to estimate the contents of ethanol, pH and rest sugar in red wine samples for both in calibration set and predicted set. Correlation coefficient (r) of prediction and root mean square error of prediction (RMSEP) were used as the evaluation indexes. The results indicate that the r and RMSEP for the prediction of ethanol content, pH and rest sugar content are 0.953, 0.983 and 0.994, and 0.161, 0.017 and 0.181, respectively. The maximum relative deviations between the ICA-NNR method predicted value and referenced value of the 22 samples in predicted set are less than 4%. The results of this paper provide a foundation for the application and further development of IR on-line red wine analyzer.
One way Doppler extractor. Volume 1: Vernier technique
NASA Technical Reports Server (NTRS)
Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.
1974-01-01
A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.
Kassouf, Amine; Maalouly, Jacqueline; Rutledge, Douglas N; Chebib, Hanna; Ducruet, Violette
2014-11-01
Plastic packaging wastes increased considerably in recent decades, raising a major and serious public concern on political, economical and environmental levels. Dealing with this kind of problems is generally done by landfilling and energy recovery. However, these two methods are becoming more and more expensive, hazardous to the public health and the environment. Therefore, recycling is gaining worldwide consideration as a solution to decrease the growing volume of plastic packaging wastes and simultaneously reduce the consumption of oil required to produce virgin resin. Nevertheless, a major shortage is encountered in recycling which is related to the sorting of plastic wastes. In this paper, a feasibility study was performed in order to test the potential of an innovative approach combining mid infrared (MIR) spectroscopy with independent components analysis (ICA), as a simple and fast approach which could achieve high separation rates. This approach (MIR-ICA) gave 100% discrimination rates in the separation of all studied plastics: polyethylene terephthalate (PET), polyethylene (PE), polypropylene (PP), polystyrene (PS) and polylactide (PLA). In addition, some more specific discriminations were obtained separating plastic materials belonging to the same polymer family e.g. high density polyethylene (HDPE) from low density polyethylene (LDPE). High discrimination rates were obtained despite the heterogeneity among samples especially differences in colors, thicknesses and surface textures. The reproducibility of the proposed approach was also tested using two spectrometers with considerable differences in their sensitivities. Discrimination rates were not affected proving that the developed approach could be extrapolated to different spectrometers. MIR combined with ICA is a promising tool for plastic waste separation that can help improve performance in this field; however further technological improvements and developments are required before it can be applied
Disorders of cochlear blood flow.
Nakashima, Tsutomu; Naganawa, Shinji; Sone, Michihiko; Tominaga, Mitsuo; Hayashi, Hideo; Yamamoto, Hiroshi; Liu, Xiuli; Nuttall, Alfred L
2003-09-01
The cochlea is principally supplied from the inner ear artery (labyrinthine artery), which is usually a branch of the anterior inferior cerebellar artery. Cochlear blood flow is a function of cochlear perfusion pressure, which is calculated as the difference between mean arterial blood pressure and inner ear fluid pressure. Many otologic disorders such as noise-induced hearing loss, endolymphatic hydrops and presbycusis are suspected of being related to alterations in cochlear blood flow. However, the human cochlea is not easily accessible for investigation because this delicate sensory organ is hidden deep in the temporal bone. In patients with sensorineural hearing loss, magnetic resonance imaging, laser-Doppler flowmetry and ultrasonography have been used to investigate the status of cochlear blood flow. There have been many reports of hearing loss that were considered to be caused by blood flow disturbance in the cochlea. However, direct evidence of blood flow disturbance in the cochlea is still lacking in most of the cases.
Assessment of the fetomaternal circulation in threatened abortion by transvaginal color Doppler.
Kurjak, A; Zudenigo, D; Predanic, M; Kupesic, S; Funduk, B
1994-01-01
Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p < 0.01). This could be a consequence of the mechanical compression caused by the hematoma. In 3 of 4 cases of missed abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).