Sample records for icast-c instrument development

  1. Adaptation and psychometric properties of the ISPCAN Child Abuse Screening Tool for use in trials (ICAST-Trial) among South African adolescents and their primary caregivers.

    PubMed

    Meinck, Franziska; Boyes, Mark E; Cluver, Lucie; Ward, Catherine L; Schmidt, Peter; DeStone, Sachin; Dunne, Michael P

    2018-05-31

    Child abuse prevention research has been hampered by a lack of validated multi-dimensional non-proprietary instruments, sensitive enough to measure change in abuse victimization or behavior. This study aimed to adapt the ICAST child abuse self-report measure (parent and child) for use in intervention studies and to investigate the psychometric properties of this substantially modified tool in a South African sample. First, cross-cultural and sensitivity adaptation of the original ICAST tools resulted in two preliminary measures (ICAST-Trial adolescents: 27 items, ICAST-Trial caregivers: 19 items). Second, ICAST-Trial data from a cluster randomized trial of a parenting intervention for families with adolescents (N = 1104, 552 caregiver-adolescent dyads) was analyzed. Confirmatory factor analysis established the hypothesized 6-factor (adolescents) and 4-factor (caregivers) structure. Removal of two items for adolescents and five for caregivers resulted in adequate model fit. Concurrent criterion validity analysis confirmed hypothesized relationships between child abuse and adolescent and caregiver mental health, adolescent behavior, discipline techniques and caregiver childhood abuse history. The resulting ICAST-Trial measures have 25 (adolescent) and 14 (caregiver) items respectively and measure physical, emotional and contact sexual abuse, neglect (both versions), and witnessing intimate partner violence and sexual harassment (adolescent version). The study established that both tools are sensitive to measuring change over time in response to a parenting intervention. The ICAST-Trial should have utility for evaluating the effectiveness of child abuse prevention efforts in similar socioeconomic contexts. Further research is needed to replicate these findings and examine cultural appropriateness, barriers for disclosure, and willingness to engage in child abuse research. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Child discipline in Qatar and Palestine: A comparative study of ICAST-R.

    PubMed

    Eldeeb, Nehal; Halileh, Samia; Alyafei, Khalid A; Ghandour, Rula; Dargham, Soha; Giacaman, Rita; Kamal, Madeeha; Imseeh, Sawsan; Korayem, Mona; Nasr, Shiraz; Mahfoud, Ziyad; Abu-Rmeileh, Niveen; Mahmoud, Mohamed H; Tawfik, Hassan; Lynch, Margaret A; Mian, Marcellina

    2016-11-01

    To compare the nature and determinants of child discipline in Qatar and Palestine among young adults through retrospective survey to develop legislation, policies and interventions for effective prevention of child maltreatment, and educational materials to promote positive discipline among parents and caregivers. Cross-sectional random household surveys were conducted in each country (Qataris N=697, Palestinians N=2064) using ISPCAN Child Abuse Screening Tool-Retrospective (ICAST-R) for young adults (18-24 years), to investigate child discipline methods into the maltreatment range. Qatari young adults were more educated (p<0.001) and had more full-time employment (p=0.004) than Palestinian young adults. Qatar reported lower physical and emotional abuse compared to their counterparts in Palestine, e.g. Hit/Punch, Kick (p<0.001) and Insult/Criticize, Threaten to be hurt/killed (p<0.001). Qatari participants found any harsh discipline they received in childhood was not reasonable and not justified compared to Palestinian participants. The more advantaged Qatari population was less likely to experience disciplinary methods that experts developing the ICAST-R defined as abuse compared to Palestinians where the higher incidence of child abuse could be attributed to lower economic advantage, lower level of education and greater exposure to violence. Suggestions are made for future studies in Qatar and Palestine to develop survey methodology with a more culturally appropriate level of intrusion, such as indirect yet meaningful child maltreatment questions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. PREFACE: International Conference on Advancement in Science and Technology 2012 (iCAST): Contemporary Mathematics, Mathematical Physics and their Applications

    NASA Astrophysics Data System (ADS)

    Ganikhodjaev, Nasir; Mukhamedov, Farrukh; Hee, Pah Chin

    2013-04-01

    The 4th International Conference on the Advancement of Science and Technology 2012 (iCAST 2012), with theme 'Contemporary Mathematics, Mathematical Physics and their Applications', took place in Kuantan, Malaysia, from Wednesday 7 to Friday 9 November 2012. The conference was attended by more than 100 participants, and hosted about 160 oral and poster papers by more than 140 pre-registered authors. The key topics of the 4th iCAST 2012 include Pure Mathematics, Applied Mathematics, Theoretical/Mathematical Physics, Dynamical Systems, Statistics and Financial Mathematics. The scientific program was rather full since after the Keynote and Invited Talks in the morning, four parallel sessions ran every day. However, according to all attendees, the program was excellent with a high level of talks and the scientific environment was fruitful; thus all attendees had a creative time. The conference aimed to promote the knowledge and development of high-quality research in mathematical fields concerned with the application of other scientific fields as well as modern technological trends in physics, chemistry, biology, medicine, economics, sociology and environmental sciences. We would like to thank the Keynote and the Invited Speakers for their significant contributions to 4th iCAST 2012. We would also like to thank the members of the International Scientific Committee and the members of the Organizing Committee. We cannot end without expressing our many thanks to International Islamic University Malaysia and our sponsors for their financial support . This volume presents selected papers which have been peer-reviewed. The editors hope that it may be useful and fruitful for scholars, researchers, and advanced technical members of the industrial laboratory facilities for developing new tools and products. Guest Editors Nasir Ganikhodjaev, Farrukh Mukhamedov and Pah Chin Hee The PDF contains the committee lists, board list and biographies of the plenary speakers.

  4. Assessing collaborative computing: development of the Collaborative-Computing Observation Instrument (C-COI)

    NASA Astrophysics Data System (ADS)

    Israel, Maya; Wherfel, Quentin M.; Shehab, Saadeddine; Ramos, Evan A.; Metzger, Adam; Reese, George C.

    2016-07-01

    This paper describes the development, validation, and uses of the Collaborative Computing Observation Instrument (C-COI), a web-based analysis instrument that classifies individual and/or collaborative behaviors of students during computing problem-solving (e.g. coding, programming). The C-COI analyzes data gathered through video and audio screen recording software that captures students' computer screens as they program, and their conversations with their peers or adults. The instrument allows researchers to organize and quantify these data to track behavioral patterns that could be further analyzed for deeper understanding of persistence and/or collaborative interactions. The article provides a rationale for the C-COI including the development of a theoretical framework for measuring collaborative interactions in computer-mediated environments. This theoretical framework relied on the computer-supported collaborative learning literature related to adaptive help seeking, the joint problem-solving space in which collaborative computing occurs, and conversations related to outcomes and products of computational activities. Instrument development and validation also included ongoing advisory board feedback from experts in computer science, collaborative learning, and K-12 computing as well as classroom observations to test out the constructs in the C-COI. These processes resulted in an instrument with rigorous validation procedures and a high inter-rater reliability.

  5. Prevalence of child abuse in school environment in Kerala, India: An ICAST-CI based survey.

    PubMed

    Kumar, Manoj Therayil; Kumar, Sebind; Singh, Surendra P; Kar, Nilamadhab

    2017-08-01

    Very few studies focus on childhood abuse in developing countries and only a small fraction of such studies explicitly deal with abuse in a school environment. The purpose of this study was to estimate the prevalence of sexual, physical, and emotional abuse in a school environment in a developing country. Abuse history was collected using the International Society for the Prevention of Child Abuse and Neglect (ISPCAN) Child Abuse Screening Tool - Children's Institutional Version (ICAST-CI). Demographic variables were also collected. Student supportive measures were provided both during and after the survey. 6682 school attending adolescents in Thrissur, Kerala participated in this cross sectional self report study. One year and lifetime prevalence of physical (75.5%, 78.5%), emotional (84.5%, 85.7%) and sexual (21.0%, 23.8%) abuse was high. Abuse was considered to be present even if an individual item from these three categories was reported. Most abuse was reported as occurring 'sometimes' rather than 'many times'. More males than females reported being victims of abuse; figures for one-year prevalence were: physical abuse (83.4% vs. 61.7%), emotional abuse (89.5% vs. 75.7%), and sexual abuse (29.5% vs. 6.2%). Various factors significantly increase the likelihood of abuse-male gender, low socioeconomic status, regular use of alcohol and drugs by family member at home, and having other difficulties at school. Children tended to report abuse less frequently if they liked attending school and if they always felt safe at school. The results highlight the urgent need to address the issue of abuse in the school environment and minimize its impact. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Factors Associated With Child Maltreatment Among Children Aged 11 to 17 Years in Community Settings of Karachi, Pakistan, Using Belsky Ecological Framework.

    PubMed

    Lakhdir, Maryam Pyar Ali; Farooq, Salima; Khan, Uzma Rahim; Parpio, Yasmin; Azam, Syed Iqbal; Razzak, Junaid; Laljee, Anjiya Aslam; Kadir, Muhammad Masood

    2017-08-01

    Child maltreatment is considered as a global social issue and results as combined effect of parental background, socioeconomic environment, family structure, and child characteristics. The aim of this study was to determine factors associated with child maltreatment among children aged 11 to 17 years in Karachi, Pakistan. A cross-sectional survey of 800 pairs (children ranging from 11 to 17 years old and their parents) was randomly selected from 32 clusters of Karachi, using multistage cluster sampling. A structured questionnaire was adopted from the International Society for the Prevention of Child Abuse and Neglect (International Child Abuse Screening Tool for Parent [ICAST-P] and for Child [ICAST-C]). Multiple linear regression technique was used to assess the association of factors with child maltreatment score, by using STATA software. Our study found that children who always get bullied and mistreated by their siblings are at increased risk of getting maltreatment by parents (adjusted β: 10.78, 95% CI = [8.5, 13.05]).The mean estimated ICAST-C score increases by 9.86 (95% CI = [6.17, 13.55]) for children with exposure of verbal abuse and quarrel within family members. The mean estimated ICAST-C score increases by 5.09 among male children as compared with female children (95% CI = [3.65, 6.52]). Among children whose family always fight with each other and whose parents have exposure to childhood maltreatment, the mean estimated ICAST-C score increases by 22.25 (95% CI = [16.53, 27.98]). This study reflects the potential factors of child maltreatment in Karachi. Our findings provide evidence to raise awareness about child maltreatment.

  7. C7 pars fracture subadjacent to C7 pedicle screw instrumentation at the caudal end of a posterior cervical instrumentation construct.

    PubMed

    Halim, Andrea; Grauer, Jonathan

    2014-07-01

    We report a case of a C7 pars fracture subadjacent to C7 pedicle screw instrumentation at the caudal end of posterior cervical instrumentation construct. To date, posterior cervical instrumentation has been "off label"; however, the US Food and Drug Administration is considering approving label indication of such instrumentation for this common surgical practice. Complications related to the techniques are reported to be relatively low. We know of no previous reports of pars fractures occurring subadjacent to such instrumentation. A 43-year-old man underwent posterior C5-C7 instrumented fusion. Postoperatively, the patient experienced cervical spine injury after a mechanical fall down stairs. Work-up detected bilateral C7 pars fractures subadjacent to the posterior instrumentation construct. After we treated the pars fracture with distal extension of the posterior fusion to the level of T2, the patient progressed to union and marked improvement of initial clinical symptoms that was maintained 2.5 years after posterior instrumentation. To our knowledge, a C7 pars fracture subadjacent to posterior cervical instrumentation construct has not been reported. We hypothesize that the pars may have been vulnerable to fracture because of excessive bone resection during foraminotomy or decortication. This complication was successfully treated by extending the fusion caudally.

  8. Spaceborne Imaging Radar-C instrument

    NASA Technical Reports Server (NTRS)

    Huneycutt, Bryan L.

    1993-01-01

    The Spaceborne Imaging Radar-C is the next radar in the series of spaceborne radar experiments, which began with Seasat and continued with SIR-A and SIR-B. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar that will be flown during at least two different seasons. The instrument operates in the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument uses engineering techniques such as beam nulling for echo tracking, pulse repetition frequency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating-point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

  9. C-smithing of Voyager 2 non-imaging instrument pointing information at Uranus

    NASA Technical Reports Server (NTRS)

    Wang, Tseng-Chan; Acton, Charles H.; Underwood, Ian M.; Synnott, Stephen P.

    1988-01-01

    The development of a family of techniques, collectively called C-smithing, for improving spacecraft nonimaging instrument pointing knowledge is discussed. C-smithing studies using data from the Voyager 2 Uranus Encounter show that significant improvements in pointing knowledge for nonimaging instruments can be achieved with these techniques. This improved pointing information can be used to regenerate instrument viewing geometry parameters for the encounter, which can then be made available to science investigators.

  10. 14 CFR Appendix C to Part 141 - Instrument Rating Course

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Instrument Rating Course C Appendix C to...) SCHOOLS AND OTHER CERTIFICATED AGENCIES PILOT SCHOOLS Pt. 141, App. C Appendix C to Part 141—Instrument...: (a) Instrument—airplane. (b) Instrument—helicopter. (c) Instrument—powered-lift. 2. Eligibility for...

  11. 14 CFR Appendix C to Part 141 - Instrument Rating Course

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Instrument Rating Course C Appendix C to... Rating Course 1. Applicability. This appendix prescribes the minimum curriculum for an instrument rating course and an additional instrument rating course, required under this part, for the following ratings...

  12. 14 CFR Appendix C to Part 141 - Instrument Rating Course

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Instrument Rating Course C Appendix C to... Rating Course 1. Applicability. This appendix prescribes the minimum curriculum for an instrument rating course and an additional instrument rating course, required under this part, for the following ratings...

  13. 14 CFR Appendix C to Part 141 - Instrument Rating Course

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Instrument Rating Course C Appendix C to... Rating Course 1. Applicability. This appendix prescribes the minimum curriculum for an instrument rating course and an additional instrument rating course, required under this part, for the following ratings...

  14. MathWorks Simulink and C++ integration with the new VLT PLC-based standard development platform for instrument control systems

    NASA Astrophysics Data System (ADS)

    Kiekebusch, Mario J.; Di Lieto, Nicola; Sandrock, Stefan; Popovic, Dan; Chiozzi, Gianluca

    2014-07-01

    ESO is in the process of implementing a new development platform, based on PLCs, for upcoming VLT control systems (new instruments and refurbishing of existing systems to manage obsolescence issues). In this context, we have evaluated the integration and reuse of existing C++ libraries and Simulink models into the real-time environment of BECKHOFF Embedded PCs using the capabilities of the latest version of TwinCAT software and MathWorks Embedded Coder. While doing so the aim was to minimize the impact of the new platform by adopting fully tested solutions implemented in C++. This allows us to reuse the in house expertise, as well as extending the normal capabilities of the traditional PLC programming environments. We present the progress of this work and its application in two concrete cases: 1) field rotation compensation for instrument tracking devices like derotators, 2) the ESO standard axis controller (ESTAC), a generic model-based controller implemented in Simulink and used for the control of telescope main axes.

  15. 26 CFR 1.501(c)(21)-2 - Same-trust instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Same-trust instrument. 1.501(c)(21)-2 Section 1... TAX (CONTINUED) INCOME TAXES (CONTINUED) Exempt Organizations § 1.501(c)(21)-2 Same—trust instrument. As trust does not meet the requirements of section 501(c)(21) if it is not established and maintained...

  16. Developing a workplace resilience instrument.

    PubMed

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  17. Developments in analytical instrumentation

    NASA Astrophysics Data System (ADS)

    Petrie, G.

    The situation regarding photogrammetric instrumentation has changed quite dramatically over the last 2 or 3 years with the withdrawal of most analogue stereo-plotting machines from the market place and their replacement by analytically based instrumentation. While there have been few new developments in the field of comparators, there has been an explosive development in the area of small, relatively inexpensive analytical stereo-plotters based on the use of microcomputers. In particular, a number of new instruments have been introduced by manufacturers who mostly have not been associated previously with photogrammetry. Several innovative concepts have been introduced in these small but capable instruments, many of which are aimed at specialised applications, e.g. in close-range photogrammetry (using small-format cameras); for thematic mapping (by organisations engaged in environmental monitoring or resources exploitation); for map revision, etc. Another innovative and possibly significant development has been the production of conversion kits to convert suitable analogue stereo-plotting machines such as the Topocart, PG-2 and B-8 into fully fledged analytical plotters. The larger and more sophisticated analytical stereo-plotters are mostly being produced by the traditional mainstream photogrammetric systems suppliers with several new instruments and developments being introduced at the top end of the market. These include the use of enlarged photo stages to handle images up to 25 × 50 cm format; the complete integration of graphics workstations into the analytical plotter design; the introduction of graphics superimposition and stereo-superimposition; the addition of correlators for the automatic measurement of height, etc. The software associated with this new analytical instrumentation is now undergoing extensive re-development with the need to supply photogrammetric data as input to the more sophisticated G.I.S. systems now being installed by clients, instead

  18. Pancreatitis Quality of Life Instrument: Development of a new instrument

    PubMed Central

    Bova, Carol; Barton, Bruce; Hartigan, Celia

    2014-01-01

    Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors). Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use. PMID:26770703

  19. Music 4C, a multi-voiced synthesis program with instruments defined in C

    NASA Astrophysics Data System (ADS)

    Beauchamp, James W.

    2003-04-01

    Music 4C is a program which runs under Unix (including Linux) and provides a means for the synthesis of arbitrary signals as defined by the C code. The program is actually a loose translation of an earlier program, Music 4BF [H. S. Howe, Jr., Electronic Music Synthesis (Norton, 1975)]. A set of instrument definitions are driven by a numerical score which consists of a series of ``events.'' Each event gives an instrument name, start time and duration, and a number of parameters (e.g., pitch) which describe the event. Each instrument definition consists of event parameters, performance variables, initializations, and a synthesis algorithmic code. Thus, the synthetic signal, no matter how complex, is precisely defined. Moreover, the resulting sounds can be overlaid in any arbitrary pattern. The program serves as a mixer of algorithmically produced sounds or recorded sounds taken from sample files or synthesized from spectrum files. A score file can be entered by hand, generated from a program, translated from a MIDI file, or generated from an alpha-numeric score using an auxiliary program, Notepro. Output sample files are in wav, snd, or aiff format. The program is provided in the C source code for download.

  20. Selecting an A1C Point-of-Care Instrument

    PubMed Central

    Yong, Ee Vonn; Rasinen, Casey

    2015-01-01

    A1C point-of-care (POC) instruments benefit patients with diabetes by facilitating clinician decision making that results in significant glycemic improvements. Three National Glycohemoglobin Standardization Program (NGSP)–certified POC products are available in the United States: the handheld A1CNow (formerly manufactured by Bayer Diabetes Care but now made by Chek Diagnostics) and two bench-top models called the Axis-Shield Afinion Analyzer and the Siemens DCA Vantage. This article compares the three available NGSP-certified POC products in terms of accuracy, precision, ease of use, cost, and additional features. Its goal is to aid health care facilities in conveniently identifying the A1C POC product that best meets their needs. It additionally reviews evidence that supports the continued use of A1C POC instruments in the clinical arena. PMID:26300614

  1. Large Instrument Development for Radio Astronomy

    NASA Astrophysics Data System (ADS)

    Fisher, J. Richard; Warnick, Karl F.; Jeffs, Brian D.; Norrod, Roger D.; Lockman, Felix J.; Cordes, James M.; Giovanelli, Riccardo

    2009-03-01

    This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.

  2. Fiber Optics Instrumentation Development

    NASA Technical Reports Server (NTRS)

    Chan, Patrick Hon Man; Parker, Allen R., Jr.; Richards, W. Lance

    2010-01-01

    This is a general presentation of fiber optics instrumentation development work being conducted at NASA Dryden for the past 10 years and recent achievements in the field of fiber optics strain sensors.

  3. Sounding Rocket Instrument Development at UAHuntsville/NASA MSFC

    NASA Technical Reports Server (NTRS)

    Kobayashi, Ken; Cirtain, Jonathan; Winebarger, Amy; Savage, Sabrina; Golub, Leon; Korreck, Kelly; Kuzin, Sergei; Walsh, Robert; DeForest, Craig; DePontieu, Bart; hide

    2013-01-01

    We present an overview of solar sounding rocket instruments developed jointly by NASA Marshall Space Flight Center and the University of Alabama in Huntsville. The High Resolution Coronal Imager (Hi-C) is an EUV (19.3 nm) imaging telescope which was flown successfully in July 2012. The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a Lyman Alpha (121.6 nm) spectropolarimeter developed jointly with the National Astronomical Observatory of Japan and scheduled for launch in 2015. The Marshall Grazing Incidence X-ray Spectrograph is a soft X-ray (0.5-1.2 keV) stigmatic spectrograph designed to achieve 5 arcsecond spatial resolution along the slit.

  4. Development of TPS flight test and operational instrumentation

    NASA Technical Reports Server (NTRS)

    Carnahan, K. R.; Hartman, G. J.; Neuner, G. J.

    1975-01-01

    Thermal and flow sensor instrumentation was developed for use as an integral part of the space shuttle orbiter reusable thermal protection system. The effort was performed in three tasks: a study to determine the optimum instruments and instrument installations for the space shuttle orbiter RSI and RCC TPS; tests and/or analysis to determine the instrument installations to minimize measurement errors; and analysis using data from the test program for comparison to analytical methods. A detailed review of existing state of the art instrumentation in industry was performed to determine the baseline for the departure of the research effort. From this information, detailed criteria for thermal protection system instrumentation were developed.

  5. Instrument pre-development activities for FLEX

    NASA Astrophysics Data System (ADS)

    Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.

    2017-09-01

    The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.

  6. HESP: Instrument control, calibration and pipeline development

    NASA Astrophysics Data System (ADS)

    Anantha, Ch.; Roy, Jayashree; Mahesh, P. K.; Parihar, P. S.; Sangal, A. K.; Sriram, S.; Anand, M. N.; Anupama, G. C.; Giridhar, S.; Prabhu, T. P.; Sivarani, T.; Sundararajan, M. S.

    Hanle Echelle SPectrograph (HESP) is a fibre-fed, high resolution (R = 30,000 and 60,000) spectrograph being developed for the 2m HCT telescope at IAO, Hanle. The major components of the instrument are a) Cassegrain unit b) Spectrometer instrument. An instrument control system interacting with a guiding unit at Cassegrain interface as well as handling spectrograph functions is being developed. An on-axis auto-guiding using the spill-over angular ring around the input pinhole is also being developed. The stellar light from the Cassegrain unit is taken to the spectrograph using an optical fiber which is being characterized for spectral transmission, focal ratio degradation and scrambling properties. The design of the thermal enclosure and thermal control for the spectrograph housing is presented. A data pipeline for the entire Echelle spectral reduction is being developed. We also plan to implement an instrument physical model based calibration into the main data pipeline and in the maintenance and quality control operations.

  7. Developing an ELT Context-Specific Teacher Efficacy Instrument

    ERIC Educational Resources Information Center

    Akbari, Ramin; Tavassoli, Kobra

    2014-01-01

    Teacher efficacy is a topic of significance in mainstream education and various instruments have been developed to measure this construct. The available instruments however, are general both in terms of their subject matter and context. To compensate for this generality, the present study aims to develop a new teacher efficacy instrument whose…

  8. NASA Planetary Science Division's Instrument Development Programs, PICASSO and MatISSE

    NASA Technical Reports Server (NTRS)

    Gaier, James R.

    2016-01-01

    The Planetary Science Division (PSD) has combined several legacy instrument development programs into just two. The Planetary Instrument Concepts Advancing Solar System Observations (PICASSO) program funds the development of low TRL instruments and components. The Maturation of Instruments for Solar System Observations (MatISSE) program funds the development of instruments in the mid-TRL range. The strategy of PSD instrument development is to develop instruments from PICASSO to MatISSE to proposing for mission development.

  9. Development of assessment instruments to measure critical thinking skills

    NASA Astrophysics Data System (ADS)

    Sumarni, W.; Supardi, K. I.; Widiarti, N.

    2018-04-01

    Assessment instruments that is commonly used in the school generally have not been orientated on critical thinking skills. The purpose of this research is to develop assessment instruments to measure critical thinking skills, to test validity, reliability, and practicality. This type of research is Research and Development. There are two stages on the preface step, which are field study and literacy study. On the development steps, there some parts, which are 1) instrument construction, 2) expert validity, 3) limited scale tryout and 4) narrow scale try-out. The developed assessment instrument are analysis essay and problem solving. Instruments were declared valid, reliable and practical.

  10. Recent developments in hydrologic instrumentation

    USGS Publications Warehouse

    Latkovich, Vito J.; Futrell, James C.; Kane, Douglas L.

    1986-01-01

    The programs of the U.S. Geological Survey require instrumentation for collecting and monitoring hydrologic data in cold regions. The availability of space-age materials and implementation of modern electronics and mechanics is making possible the recent developments of hydrologic instrumentation, especially in the area of measuring streamflow under ice cover. Material developments include: synthetic-fiber sounding and tag lines; polymer (plastic) sheaves, pulleys, and sampler components; and polymer (plastic) current-meter bucket wheels. Electronic and mechanical developments include: a current-meter digitizer; a fiber-optic closure system for current-meters; non-contact water-level sensors; an adaptable hydrologic data acquisition system; a minimum data recorder; an ice rod; an ice foot; a handled sediment sampler; a light weight ice auger with improved cutter head and blades; and an ice chisel.

  11. Instrument development and the measurement of unitary constructs.

    PubMed

    Carboni, J T

    1992-01-01

    This article initiates needed dialogue on the development of instruments to measure unitary constructs. The concept of measurement is explored and current measurement in Rogerian research is considered in light of the issues raised in the discussion. The human field - environmental field relationship is presented as the clinical practice area serving as the basis for the development of a unitary instrument that purports to measure field pattern. The instrument entitled Mutual Exploration of the Healing Human Field - Environmental Field Relationship is offered as a beginning effort in constructing an instrument that measures a unitary phenomenon. Rogerian scholars are provided with the challenge to continue the debate regarding the whole field of measurement and the development of unitary tools.

  12. Development of the Electron Drift Instrument (EDI) for Cluster

    NASA Technical Reports Server (NTRS)

    Quinn, Jack; Christensen, John L. (Technical Monitor)

    2001-01-01

    The Electron Drift Instrument (EDI) is a new technique for measuring electric fields in space by detecting the effect on weak beams of test electrons. This U.S. portions of the technique, flight hardware, and flight software were developed for the Cluster mission under this contract. Dr. Goetz Paschmann of the Max Planck Institute in Garching, Germany, was the Principle Investigator for Cluster EDI. Hardware for Cluster was developed in the U.S. at the University of New Hampshire, Lockheed Palo Alto Research Laboratory, and University of California, San Diego. The Cluster satellites carrying the original EDI instruments were lost in the catastrophic launch failure of first flight of the Arianne-V rocket in 1996. Following that loss, NASA and ESA approved a rebuild of the Cluster mission, for which all four satellites were successfully launched in the Summer of 2000. Limited operations of EDI were also obtained on the Equator-S satellite, which was launched in December, 1997. A satellite failure caused a loss of the Equator-S mission after only 5 months, but these operations were extremely valuable in learning about the characteristics and operations of the complex EDI instrument. The Cluster mission, satellites, and instruments underwent an extensive on-orbit commissioning phase in the Fall of 2000, carrying over through January 2001. During this period all elements of the instruments were checked and careful measurements of inter-experiments interferences were made. EDI is currently working exceptionally well in orbit. Initial results verify that all aspects of the instrument are working as planned, and returning highly valuable scientific information. The first two papers describing EDI on-orbit results have been submitted for publication in April, 2001. The principles of the EDI technique, and its implementation on Cluster are described in two papers by Paschmann et al., attached as Appendices A and B. The EDI presentation at the formal Cluster Commissioning

  13. The development of an airborne instrumentation computer system for flight test

    NASA Technical Reports Server (NTRS)

    Bever, G. A.

    1984-01-01

    Instrumentation interfacing frequently requires the linking of intelligent systems together, as well as requiring the link itself to be intelligent. The airborne instrumentation computer system (AICS) was developed to address this requirement. Its small size, approximately 254 by 133 by 140 mm (10 by 51/4 by 51/2 in), standard bus, and modular board configuration give it the ability to solve instrumentation interfacing and computation problems without forcing a redesign of the entire unit. This system has been used on the F-15 aircraft digital electronic engine control (DEEC) and its follow on engine model derivative (EMD) project and in an OV-1C Mohawk aircraft stall speed warning system. The AICS is presently undergoing configuration for use on an F-104 pace aircraft and on the advanced fighter technology integration (AFTI) F-111 aircraft.

  14. Beam Instrument Development System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DOOLITTLE, LAWRENCE; HUANG, GANG; DU, QIANG

    Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.

  15. The International development of PROQOL-HCV: An instrument to assess the health-related quality of life of patients treated for Hepatitis C virus.

    PubMed

    Armstrong, Andrew Richard; Herrmann, Susan Elizabeth; Chassany, Olivier; Lalanne, Christophe; Da Silva, Mariliza Henrique; Galano, Eliana; Carrieri, Patrizia M; Estellon, Vincent; Sogni, Philippe; Duracinsky, Martin

    2016-08-23

    Hepatitis C virus (HCV) compromises Health-related Quality of Life (HRQL) with detriments to Physical, Mental and Social health domains. Treatment with interferon and ribavirin is associated with side effects which further impair HRQL. New treatments appear potent, effective and tolerable. However, Patient Reported Outcomes instruments that capture the impact on HRQL for people with hepatitis C are largely non-specific and will be needed in the new treatment era. Therefore, we developed a conceptually valid multidimensional model of HCV-specific quality of life and pilot survey instrument, the Patient Reported Outcome Quality of Life survey for HCV (PROQOL-HCV). HCV patients from France (n = 30), Brazil (n = 20) and Australia (n = 20) were interviewed to investigate HCV-HRQL issues raised in the scientific literature and by treatment specialists. Interviews were recorded, transcribed and translated into English and French. Fifteen content dimensions were derived from the qualitative analysis, refined and fitted to four domains: (1) Physical Health included: fatigue, pain, sleep, sexual impairment and physical activity; (2) Mental Health: psychological distress, psychosocial impact, and cognition; (3) Social Health: support, stigma, social activity, substance use; (4) TREATMENT: management, side effects, and fear of treatment failure. The impact of some dimensions extended beyond their primary domain including: physical activity, cognition, sleep, sexual impairment, and the three treatment dimensions. A bank of 300 items was constructed to reflect patient reports and, following expert review, reduced to a 72-item pilot questionnaire. We present a conceptually valid multidimensional model of HCV-specific quality of life and the pilot survey instrument, PROQOL-HCV. The model is widely inclusive of the experience of hepatitis C and the first to include the treatment dimension.

  16. The Vector Electric Field Instrument on the C/NOFS Satellite

    NASA Technical Reports Server (NTRS)

    Pfaff, R.; Kujawski, J.; Uribe, P.; Bromund, K.; Fourre, R.; Acuna, M.; Le, G.; Farrell, W.; Holzworth, R.; McCarthy, M.; hide

    2008-01-01

    We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

  17. Nurses' Attitudes Regarding the Safe Handling of Patients Who Are Morbidly Obese: Instrument Development and Psychometric Analysis.

    PubMed

    Bejciy-Spring, Susan; Vermillion, Brenda; Morgan, Sally; Newton, Cheryl; Chucta, Sheila; Gatens, Cindy; Zadvinskis, Inga; Holloman, Christopher; Chipps, Esther

    2016-12-01

    Nurses' attitudes play an important role in the consistent practice of safe patient handling behaviors. The purposes of this study were to develop and assess the psychometric properties of a newly developed instrument measuring attitudes of nurses related to the care and safe handling of patients who are obese. Phases of instrument development included (a) item generation, (b) content validity assessment, (c) reliability assessment, (d) cognitive interviewing, and (e) construct validity assessment through factor analysis. The final data from the exploratory factor analysis produced a 26-item multidimensional instrument that contains 9 subscales. Based on the factor analysis, a 26-item instrument can be used to examine nurses' attitudes regarding patients who are morbidly obese and related safe handling practices.

  18. Policy instruments for pollution control in developing countries.

    PubMed

    Eskeland, G S; Jimenez, E

    1992-07-01

    Economic development in developing countries must be accomplished in a manner that does not harm the environment with pollution. Pollution harms human health and productivity. Thus appropriate strategies must be developed that promote growth, reduce poverty, and protect the environment. A review of the current literature is performed with attention paid to cost-effective interventions i.e., comparisons of regulatory and fiscal instruments that can reduce pollution. Both direct instruments (like effluent charges, tradable permits, deposit refund systems, emission regulations and regulatory agency funding for purification, cleanup, waste disposal, and enforcement) and indirect instruments (like input/output taxes and subsidies, substitution subsidies, abatement inputs, regulation of equipment and processes, and development of clean technologies) are examined. Examples are used to show how indirect instruments can be successful when monitoring and enforcement is too costly. A careful examination of distributive concerns illustrate how the effect on the poor may need particular consideration and how groups with vested interests can help evaluate the probable success of such interventions.

  19. The Development of the Graphics-Decoding Proficiency Instrument

    ERIC Educational Resources Information Center

    Lowrie, Tom; Diezmann, Carmel M.; Kay, Russell

    2011-01-01

    The graphics-decoding proficiency (G-DP) instrument was developed as a screening test for the purpose of measuring students' (aged 8-11 years) capacity to solve graphics-based mathematics tasks. These tasks include number lines, column graphs, maps and pie charts. The instrument was developed within a theoretical framework which highlights the…

  20. Initial Development of C.A.T.E.S.: A Simulation-Based Competency Assessment Instrument for Neonatal Nurse Practitioners.

    PubMed

    Cates, Leigh Ann; Bishop, Sheryl; Armentrout, Debra; Verklan, Terese; Arnold, Jennifer; Doughty, Cara

    2015-01-01

    Determine content validity of global statements and operational definitions and choose scenarios for Competency, Assessment, Technology, Education, and Simulation (C.A.T.E.S.), instrument in development to evaluate multidimensional competency of neonatal nurse practitioners (NNPs). Real-time Delphi (RTD) method to pursue four specific aims (SAs): (1) identify which cognitive, technical, or behavioral dimension of NNP competency accurately reflects each global statement; (2) map the global statements to the National Association of Neonatal Nurse Practitioners (NANNP) core competency domains; (3) define operational definitions for the novice to expert performance subscales; and (4) determine the essential scenarios to assess NNPs. Twenty-five NNPs and nurses with competency and simulation experience Main outcome variable: One hundred percent of global statements correct for competency dimension and all but two correct for NANNP domain. One hundred percent novice to expert operational definitions and eight scenarios chosen. Content validity determined for global statements and novice to expert definitions and essential scenarios chosen.

  1. An ultra-high temperature testing instrument under oxidation environment up to 1800 °C.

    PubMed

    Cheng, Xiangmeng; Qu, Zhaoliang; He, Rujie; Ai, Shigang; Zhang, Rubing; Pei, Yongmao; Fang, Daining

    2016-04-01

    A new testing instrument was developed to measure the high-temperature constitutive relation and strength of materials under an oxidative environment up to 1800 °C. A high temperature electric resistance furnace was designed to provide a uniform temperature environment for the mechanical testing, and the temperature could vary from room temperature (RT) to 1800 °C. A set of semi-connected grips was designed to reduce the stress. The deformation of the specimen gauge section was measured by a high temperature extensometer. The measured results were acceptable compared with the results from the strain gauge method. Meanwhile, tensile testing of alumina was carried out at RT and 800 °C, and the specimens showed brittle fracture as expected. The obtained Young's modulus was in agreement with the reported value. In addition, tensile experiment of ZrB2-20%SiC ceramic was conducted at 1700 °C and the high-temperature tensile stress-strain curve was first obtained. Large plastic deformation up to 0.46% and the necking phenomenon were observed before the fracture of specimen. This instrument will provide a powerful research tool to study the high temperature mechanical property of materials under oxidation and is benefit for the engineering application of materials in aerospace field.

  2. AIRS-Light Instrument Concept and Critical Technology Development

    NASA Technical Reports Server (NTRS)

    Maschhoff, Kevin

    2001-01-01

    Understanding Earth's climate, atmospheric transport mechanisms, and the hydrologic cycle requires a precise knowledge of global atmospheric circulation, temperature profiles, and water vapor distribution. The accuracy of advanced sounders such as AIRS/AMSU/HSB on NASA's Aqua spacecraft can match radiosonde accuracy. It is essential to fold those capabilities fully into the NPOESS, enabling soundings of radiosonde accuracy, every 6 hours around the globe on an operational basis. However, the size, mass, power demands, and thermal characteristics of the Aqua sounding instrument suite cannot be accommodated on the NPOESS spacecraft. AIRS-Light is an instrument concept, developed under the Instrument Incubator Program, which provides IR sounding performance identical to the AIRS instrument, but uses advances in HgCdTe FPA technology and pulse tube cooler technology, as well as design changes to dramatically reduce the size, mass, and power demand, allowing AIRS-Light to meet all NPOESS spacecraft interface requirements. The instrument concept includes substantial re-use of AIRS component designs, including the complex AIRS FPA, to reduce development risk and cost. The AIRS-Light Instrument Incubator program fostered the development of photovoltaic-mode HgCdTe detector array technology for the 13.5-15.4 micron band covered by photoconductive-mode HgCdTe arrays in AIRS, achieved state of the art results in this band, and substantially reduced the development risk for this last new technology needed for AIRS-Light implementation, A demonstration of a prototype 14.5-15.4 micron band IRFPA in a reduced heat-load dewar together with the IMAS pulse tube cryocooler is in progress.

  3. Micro-computed tomographic comparison of nickel-titanium rotary versus traditional instruments in C-shaped root canal system.

    PubMed

    Yin, Xingzhe; Cheung, Gary Shun-Pan; Zhang, Chengfei; Masuda, Yoshiko Murakami; Kimura, Yuichi; Matsumoto, Koukichi

    2010-04-01

    The purpose of this study was to assess the efficacy of instrumentation of C-shaped canals with ProTaper rotary system and traditional instruments by using micro-computed tomography (micro-CT). Twenty-four mandibular molars with C-shaped canals were selected in pairs and sorted equally into 2 groups, which were assigned for instrumentation by ProTaper rotary system (ProTaper group) or by K-files and Gates-Glidden burs (Hand Instrument group). Three-dimensional images were constructed by micro-CT. The volume of dentin removed, uninstrumented canal area, time taken for instrumentation, and iatrogenic error of instrumentation were investigated. Hand Instrument group showed greater amount of volumetric dentin removal and left less uninstrumented canal area than ProTaper group (P < .01). The time needed for instrumentation was shorter for ProTaper group than for Hand Instrument group (P < .05). No instrument breakage occurred in both groups, but more conspicuous procedural errors were detected in Hand Instrument group than for ProTaper group. It was concluded that ProTaper rotary system maintained the canal curvature with speediness and few procedural errors, whereas traditional instrumentation can clean more canal surface. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Developing instrumentation to characterize thermoelectric generator modules.

    PubMed

    Liu, Dawei; Li, Qiming; Peng, Wenbo; Zhu, Lianjun; Gao, Hu; Meng, Qingsen; Jin, A J

    2015-03-01

    Based on the law of physics, known as "Seebeck effect," a thermoelectric generator (TEG) produces electricity when the temperature differential is applied across the TEG. This article reports a precision method in characterizing TEG modules. A precision instrument is constructed to study thermoelectric conversion in terms of output power and efficiency of TEG modules. The maximum allowable TEG module size is 150 mm, and the preferred size is from 30 mm to 60 mm. During measurements, the highest hot side temperature is 500 °C and the cold side temperature can be adjusted from room temperature to 100 °C. A mechanical structure is developed to control the pressure and parallelism of the clamping force of the TEG on both its hot and cold sides. A heat flux measurement module is installed at its cold side, and the heat flux through TEGs can be measured in position. Finally, the energy conversion efficiency of TEGs is calculated from experimental data of both an output power and a heat flux.

  5. Comparison of contemporary occipitocervical instrumentation techniques with and without C1 lateral mass screws.

    PubMed

    Wolfla, Christopher E; Salerno, Simon A; Yoganandan, Narayan; Pintar, Frank A

    2007-09-01

    This study was designed to test the kinematic properties of three occiput-C2 instrumentation constructs with and without supplemental rigid C1 fixation. The results are compared with intact specimens and with constructs incorporating contemporary cabling techniques. Five unembalmed human cadaver specimens underwent range of motion (ROM) testing in the intact condition, followed by destabilization with odontoid osteotomy. Destabilized specimens then underwent ROM testing with each of seven occipitocervical instrumentation constructs, all incorporating occipital screws: C1 and C2 sublaminar cables with cable connectors, C2 pars screws +/- C1 lateral mass screws, C2 lamina screws +/- C1 lateral mass screws, and C1-C2 transarticular screws +/- C1 lateral mass screws. All seven constructs demonstrated significantly lower ROM in all loading modes than intact specimens (P < 0.05). With a single exception, the addition of C1 lateral mass screws to the screw-based constructs produced no significant change in ROM in any of the loading modes. Compared with intact specimens, constructs anchored by C1-C2 transarticular screws demonstrated the greatest decrease in ROM, and those anchored by sublaminar cables demonstrated the least decrease in ROM. Any of the tested screw-based constructs are likely to provide adequate support for the patient with an unstable craniocervical junction. Therefore, the choice of construct should be based on anatomic considerations. The routine incorporation of C1 lateral mass screws into occipitocervical instrumentation constructs does not seem necessary.

  6. Instrument Development for Examining Student Attrition

    ERIC Educational Resources Information Center

    McRoberts, Timothy J.; Miller, Tess

    2015-01-01

    Instruments designed to track student changes in higher education are essential for monitoring program development in competitive higher education markets. As part of a developmental evaluation, a student questionnaire was developed and piloted to examine attrition rates in college programs. The purpose of the questionnaire was to explore factors…

  7. Development of an Instrument for Assessing Elder Care Needs

    ERIC Educational Resources Information Center

    Åhsberg, Elizabeth; Fahlström, Gunilla; Rönnbäck, Eva; Granberg, Ann-Kristin; Almborg, Ann-Helene

    2017-01-01

    Objective: To construct a needs assessment instrument for older people using a standardized terminology (International classification of functioning, disability, and health [ICF]) and assess its psychometrical properties. Method: An instrument was developed comprising questions to older people regarding their perceived care needs. The instrument's…

  8. Assessing hospitals' clinical risk management: Development of a monitoring instrument

    PubMed Central

    2010-01-01

    Background Clinical risk management (CRM) plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. Methods The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals) was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. Results The monitoring instrument consists of 28 main questions organized in three sections: 1) Implementation and organizational integration of CRM, 2) Strategic objectives and operational implementation of CRM at hospital level, and 3) Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian). It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. Conclusions We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety. PMID:21144039

  9. A finite element investigation of upper cervical instrumentation.

    PubMed

    Puttlitz, C M; Goel, V K; Traynelis, V C; Clark, C R

    2001-11-15

    The finite element technique was used to predict changes in biomechanics that accompany the application of a novel instrumentation system designed for use in the upper cervical spine. To determine alterations in joint loading, kinematics, and instrumentation stresses in the craniovertebral junction after application of a novel instrumentation system. Specifically, this design was used to assess the changes in these parameters brought about by two different cervical anchor types: C2 pedicle versus C2-C1 transarticular screws, and unilateral versus bilateral instrumentation. Arthrodesis procedures can be difficult to obtain in the highly mobile craniovertebral junction. Solid fusion is most likely achieved when motion is eliminated. Biomechanical studies have shown that C1-C2 transarticular screws provide good stability in craniovertebral constructs; however, implantation of these screws is accompanied by risk of vertebral artery injury. A novel instrumentation system that can be used with transarticular screws or with C2 pedicle screws has been developed. This design also allows for unilateral or bilateral implantation. However, the authors are unaware of any reports to date on the changes in joint loading or instrumentation stresses that are associated with the choice of C2 anchor or unilateral/bilateral use. A ligamentous, nonlinear, sliding contact, three-dimensional finite element model of the C0-C1-C2 complex and a novel instrumentation system was developed. Validation of the model has been previously reported. Finite element models representing combinations of cervical anchor type (C1-C2 transarticular screws vs. C2 pedicle screws) and unilateral versus bilateral instrumentation were evaluated. All models were subjected to compression with pure moments in either flexion, extension, or lateral bending. Kinematic reductions with respect to the intact (uninjured and without instrumentation) case caused by instrumentation use were reported. Changes in loading

  10. The stringing of Italian keyboard instruments c.1500- c.1650. Part One: Discussion and bibliography

    NASA Astrophysics Data System (ADS)

    Wraight, Ralph Denzil

    1997-12-01

    The problem of deciding which stringing materials were used on Italian string keyboard instruments is approached in two ways, by examination of documentary evidence and through the evidence of the instruments. Information on 748 instruments is presented in a catalogue which examines and describes the original condition. 89 new attributions of instruments are presented. From this comprehensive pool of information on the compasses and string lengths of the instruments made it is argued that previous authors worked with too little information to enable accurate conclusions to be drawn. Documentary evidence alone is held to be inconclusive in showing which string material was used for particular instruments at specific periods, and not as useful as argued by some previous authors. The scaling design of instruments is considered and conclusions are advanced that most virginals were designed to be strung with iron wire. It is also argued that most 16th-century harpsichords were intended to be strung with iron wire. A change to brass- scaled designs took place from about 1600-1650, and this also coincided with a loss of popularity of designs employing a 4' stop. The orientation of the first and last notes of Italian compasses on c and f notes is argued to be a consequence of music theory and not a sure indication of pitch level. There were some 16th-century harpsichords made for a pitch a fourth lower than other 8' instruments, but it is argued that there were not two groups a fourth apart in pitch. The string lengths used in the cities of Venice, Florence, Rome, Milan, and Naples are listed and show that a normal 8' range covering a whole tone was in use in all areas at various times. The evidence of the string lengths suggests that instrument makers organised the pitches of instruments into 1/3 tone steps, a scheme which may be related to the apparent use of a 1/3 comma meantone tuning system in an organ of 1494 and clavichord of 1543, before it was described in print

  11. T-34C back seat instrument panel

    NASA Image and Video Library

    1997-05-15

    The back seat instrument panel on the NASA T-34C chase plane. In its role as a military trainer, the instructor pilot would ride in the back seat, while the student would be in the front seat. As a chase plane, the back seat would be occupied by a photographer. The aircraft was previously used at the Lewis Research Center in propulsion experiments involving turboprop engines, and was used as a chase aircraft at Dryden for smaller and slower research projects. Chase aircraft accompany research flights for photography and video purposes, and also as support for safety and research. At Dryden, the T-34 is used mainly for smaller remotely piloted vehicles which fly slower than NASA's F-18's, used for larger scale projects. This aircraft was returned to the U.S. Navy in May of 2002. The T-34C, built by Beech, carries a crew of 2 and is nicknamed the Mentor.

  12. Laser light scattering instrument advanced technology development

    NASA Technical Reports Server (NTRS)

    Wallace, J. F.

    1993-01-01

    The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

  13. Lunar Reference Suite to Support Instrument Development and Testing

    NASA Technical Reports Server (NTRS)

    Allen, Carlton; Sellar, Glenn; Nunez, Jorge I.; Winterhalter, Daniel; Farmer, Jack

    2010-01-01

    Astronauts on long-duration lunar missions will need the capability to "high-grade" their samples - to select the highest value samples for transport to Earth - and to leave others on the Moon. Instruments that may be useful for such high-grading are under development. Instruments are also being developed for possible use on future lunar robotic landers, for lunar field work, and for more sophisticated analyses at a lunar outpost. The Johnson Space Center Astromaterials acquisition and Curation Office (JSC Curation) wll support such instrument testing by providing lunar sample "ground truth".

  14. Assessment of Work Performance (AWP)--development of an instrument.

    PubMed

    Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M

    2006-01-01

    Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.

  15. PASSCAL Instrument Center Support for Cryoseismology: Methodologies, Challenges, Development and Instrumentation

    NASA Astrophysics Data System (ADS)

    Beaudoin, B. C.; Anderson, K. R.; Bilek, S. L.; Carpenter, P.; Childs, D.; Chung, P.; Huerta, A. D.; Lingutla, N.; Nikolaus, K.; Winberry, J. P.

    2017-12-01

    Remote portable seismic stations are, in most cases, constrained by logistics and cost. High latitude operations introduce environmental, technical and logistical challenges that require substantially more engineering work to ensure robust, high quality data return. Since 2006, IRIS PASSCAL has been funded by NSF to develop, deploy, and maintain a pool of polar specific seismic stations. At roughly the same time, PASSCAL began supporting experiments specifically targeting glacier dynamics such as the mechanisms of subglacial hydrology, basal shear stress, ice stream stick slip mechanisms, and glacier seismicity. Although much of the development for high-latitude deployments was directly applicable to cryoseismology, these new experiments introduced a unique series of challenges including high ablation, standing water, and moving stations. Our polar development objectives have focused on: Reducing station power requirements, size and weight; Extending the operational temperature of a station; Simplifying logistics; Engineering solutions that are cost effective, manufacturable, serviceable and reusable; And, developing high-latitude communications for both state-of-health and data transmission. To these ends, PASSCAL continues testing new power storage technology, refining established power systems for lighter and smaller power banks, and exploring telemetry solutions to increase high-bandwidth communication options and abilities for remote seismic stations. Further enhancing PASSCAL's ability to support cryoseismology is a recent NSF funded collaborative effort lead by Central Washing University joined by IRIS and New Mexico Tech to build a Geophysical Earth Observatory for Ice Covered Environments (GEOICE). The GEOICE instrument, power system and other integrated ancillary components are designed to require minimal installation time and logistical load (i.e., size and weight), while maximizing ease-of-use in the field and optimizing costs of instrumentation and

  16. A Framework for Instrument Development of a Choice Experiment: An Application to Type 2 Diabetes.

    PubMed

    Janssen, Ellen M; Segal, Jodi B; Bridges, John F P

    2016-10-01

    Choice experiments are increasingly used to obtain patient preference information for regulatory benefit-risk assessments. Despite the importance of instrument design, there remains a paucity of literature applying good research principles. We applied a novel framework for instrument development of a choice experiment to measure type 2 diabetes mellitus treatment preferences. Applying the framework, we used evidence synthesis, expert consultation, stakeholder engagement, pretest interviews, and pilot testing to develop a best-worst scaling (BWS) and discrete choice experiment (DCE). We synthesized attributes from published DCEs for type 2 diabetes, consulted clinical experts, engaged a national advisory board, conducted local cognitive interviews, and pilot tested a national survey. From published DCEs (n = 17), ten attribute categories were extracted with cost (n = 11) having the highest relative attribute importance (RAI) (range 6-10). Clinical consultation and stakeholder engagement identified six attributes for inclusion. Cognitive pretesting with local diabetes patients (n = 25) ensured comprehension of the choice experiment. Pilot testing with patients from a national sample (n = 50) identified nausea as most important (RAI for DCE: 10 [95 % CI 8.5-11.5]; RAI for BWS: 10 [95 % CI 8.9-11.1]). The developed choice experiment contained five attributes (A1c decrease, blood glucose stability, low blood glucose, nausea, additional medicine, and cost). The framework for instrument development of a choice experiment included five stages of development and incorporated multiple stakeholder perspectives. Further comparisons of instrument development approaches are needed to identify best practices. To facilitate comparisons, researchers need to be encouraged to publish or discuss their instrument development strategies and findings.

  17. Actual curriculum development practices instrument: Testing for factorial validity

    NASA Astrophysics Data System (ADS)

    Foi, Liew Yon; Bakar, Kamariah Abu; Hamzah, Mohd Sahandri Gani; Alwi, Nor Hayati

    2014-09-01

    The Actual Curriculum Development Practices Instrument (ACDP-I) was developed and the factorial validity of the ACDP-I was tested (n = 107) using exploratory factor analysis procedures in the earlier work of [1]. Despite the ACDP-I appears to be content and construct valid instrument with very high internal reliability qualities for using in Malaysia, the accumulated evidences are still needed to provide a sound scientific basis for the proposed score interpretations. Therefore, the present study addresses this concern by utilising the confirmatory factor analysis to further confirm the theoretical structure of the variable Actual Curriculum Development Practices (ACDP) and enrich the psychometrical properties of ACDP-I. Results of this study have practical implication to both researchers and educators whose concerns focus on teachers' classroom practices and the instrument development and validation process.

  18. Flight Software Development for the CHEOPS Instrument with the CORDET Framework

    NASA Astrophysics Data System (ADS)

    Cechticky, V.; Ottensamer, R.; Pasetti, A.

    2015-09-01

    CHEOPS is an ESA S-class mission dedicated to the precise measurement of radii of already known exoplanets using ultra-high precision photometry. The instrument flight software controlling the instrument and handling the science data is developed by the University of Vienna using the CORDET Framework offered by P&P Software GmbH. The CORDET Framework provides a generic software infrastructure for PUS-based applications. This paper describes how the framework is used for the CHEOPS application software to provide a consistent solution for to the communication and control services, event handling and FDIR procedures. This approach is innovative in four respects: (a) it is a true third-party reuse; (b) re-use is done at specification, validation and code level; (c) the re-usable assets and their qualification data package are entirely open-source; (d) re-use is based on call-back with the application developer providing functions which are called by the reusable architecture. File names missing from here on out (I tried to mimic the files names from before.)

  19. Joint investigation of working conditions, environmental and system performance at recycling centres--development of instruments and their usage.

    PubMed

    Engkvist, I-L; Eklund, J; Krook, J; Björkman, M; Sundin, E; Svensson, R; Eklund, M

    2010-05-01

    Recycling is a new and developing industry, which has only been researched to a limited extent. This article describes the development and use of instruments for data collection within a multidisciplinary research programme "Recycling centres in Sweden - working conditions, environmental and system performance". The overall purpose of the programme was to form a basis for improving the function of recycling centres with respect to these three perspectives and the disciplines of: ergonomics, safety, external environment, and production systems. A total of 10 instruments were developed for collecting data from employees, managers and visitors at recycling centres, including one instrument for observing visitors. Validation tests were performed in several steps. This, along with the quality of the collected data, and experience from the data collection, showed that the instruments and methodology used were valid and suitable for their purpose. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  20. Development of an instrument for the evaluation of advanced life support performance.

    PubMed

    Peltonen, L-M; Peltonen, V; Salanterä, S; Tommila, M

    2017-10-01

    Assessing advanced life support (ALS) competence requires validated instruments. Existing instruments include aspects of technical skills (TS), non-technical skills (NTS) or both, but one instrument for detailed assessment that suits all resuscitation situations is lacking. This study aimed to develop an instrument for the evaluation of the overall ALS performance of the whole team. This instrument development study had four phases. First, we reviewed literature and resuscitation guidelines to explore items to include in the instrument. Thereafter, we interviewed resuscitation team professionals (n = 66), using the critical incident technique, to determine possible additional aspects associated with the performance of ALS. Second, we developed an instrument based on the findings. Third, we used an expert panel (n = 20) to assess the validity of the developed instrument. Finally, we revised the instrument based on the experts' comments and tested it with six experts who evaluated 22 video recorded resuscitations. The final version of the developed instrument had 69 items divided into adherence to guidelines (28 items), clinical decision-making (5 items), workload management (12 items), team behaviour (8 items), information management (6 items), patient integrity and consideration of laymen (4 items) and work routines (6 items). The Cronbach's α values were good, and strong correlations between the overall performance and the instrument were observed. The instrument may be useful for detailed assessment of the team's overall performance, but the numerous items make the use demanding. The instrument is still under development, and more research is needed to determine its psychometric properties. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Qualitative adaptation of child behaviour problem instruments in a developing-country setting.

    PubMed

    Khan, B; Avan, B I

    2014-07-08

    A key barrier to epidemiological research on child behaviour problems in developing countries is the lack of culturally relevant, internationally recognized psychometric instruments. This paper proposes a model for the qualitative adaptation of psychometric instruments in developing-country settings and presents a case study of the adaptation of 3 internationally recognized instruments in Pakistan: the Child Behavior Checklist, the Youth Self-Report and the Teacher's Report Form. This model encompassed a systematic procedure with 6 distinct phases to minimize bias and ensure equivalence with the original instruments: selection, deliberation, alteration, feasibility, testing and formal approval. The process was conducted in collaboration with the instruments' developer. A multidisciplinary working group of experts identified equivalence issues and suggested modifications. Focus group discussions with informants highlighted comprehension issues. Subsequently modified instruments were thoroughly tested. Finally, the instruments' developer approval further validated the qualitative adaptation. The study proposes a rigorous and systematic model to effectively achieve cultural adaptation of psychometric instruments.

  2. Instrumental Aid by Japanese Official Development Assistance for Astronomy in Developing Countries

    NASA Astrophysics Data System (ADS)

    Kitamura, Masatoshi

    In order to promote education and research in developing countries, the Japanese Government has been providing developing countries with high-grade equipment under the framework of the Official Development Assistance (ODA) cooperation programme since 1982. Under this successful cooperation programme, 24 astronomical instruments have been donated to 19 developing countries up to the end of the Japanese fiscal year 2003. The instruments donated included university-level reflecting telescopes, as well as modern planetaria used for educational purposes, together with various accessories. This paper describes a continuation of the previous ODA donations (Astronomical Herald 1997) and the subsequent follow-up programmes provided with the assistance of Japan International Cooperation Agency (JICA).

  3. Determining and Forecasting Savings from Competing Previously Sole Source/Noncompetitive Contracts

    DTIC Science & Technology

    1978-10-01

    SUMMARY A. BACKGROUND. Within the defense market , It is difficult to isolate, identify and quantify the impact of competition on acquisition costs...63 C. F04iCASTING METhODOLOGY .................. . 7 0. COMPETITION INDEX . . . . . . . . . . . . . . . . . . .. . 77 E . USE AS A FORECASTING TOOL...program is still active. e . From this projection, calculate the actual total contract price coiencing with the buy-out competition by multiplying the

  4. The Space Telescope SI C&DH system. [Scientific Instrument Control and Data Handling Subsystem

    NASA Technical Reports Server (NTRS)

    Gadwal, Govind R.; Barasch, Ronald S.

    1990-01-01

    The Hubble Space Telescope Scientific Instrument Control and Data Handling Subsystem (SI C&DH) is designed to interface with five scientific instruments of the Space Telescope to provide ground and autonomous control and collect health and status information using the Standard Telemetry and Command Components (STACC) multiplex data bus. It also formats high throughput science data into packets. The packetized data is interleaved and Reed-Solomon encoded for error correction and Pseudo Random encoded. An inner convolutional coding with the outer Reed-Solomon coding provides excellent error correction capability. The subsystem is designed with the capacity for orbital replacement in order to meet a mission life of fifteen years. The spacecraft computer and the SI C&DH computer coordinate the activities of the spacecraft and the scientific instruments to achieve the mission objectives.

  5. Development of test methodology for dynamic mechanical analysis instrumentation

    NASA Technical Reports Server (NTRS)

    Allen, V. R.

    1982-01-01

    Dynamic mechanical analysis instrumentation was used for the development of specific test methodology in the determination of engineering parameters of selected materials, esp. plastics and elastomers, over a broad range of temperature with selected environment. The methodology for routine procedures was established with specific attention given to sample geometry, sample size, and mounting techniques. The basic software of the duPont 1090 thermal analyzer was used for data reduction which simplify the theoretical interpretation. Clamps were developed which allowed 'relative' damping during the cure cycle to be measured for the fiber-glass supported resin. The correlation of fracture energy 'toughness' (or impact strength) with the low temperature (glassy) relaxation responses for a 'rubber-modified' epoxy system was negative in result because the low-temperature dispersion mode (-80 C) of the modifier coincided with that of the epoxy matrix, making quantitative comparison unrealistic.

  6. Holy Trinity of Instrumentation Development

    NASA Astrophysics Data System (ADS)

    Uršič, Rok; Šolar, Borut

    2004-11-01

    Being user friendly should be the main guidance, beside the self-understood high performance, in today's instrumentation development. Here we identify three components of the user-friendly policy: the all-in-one concept, customization, and connectivity. All-in-one is the concept of unification of various building blocks and thus various functionalities in one product. The customization is enabled by the product's reconfigurability that allows a product to grow and support new requirements and applications without changing hardware. The consequence of the two is the capacity of the single instrument to perform a variety of tasks that before were split among different devices. The last of the three is connectivity that improves the relationship between controls and beam diagnostics, brings out-of-the-crate freedom, and opens unforeseen possibilities for intra-accelerator cooperation and remote technical support.

  7. Development of SIR-C Ground Calibration Equipment

    NASA Technical Reports Server (NTRS)

    Freeman, A.; Azeem, M.; Haub, D.; Sarabandi, K.

    1993-01-01

    SIR-C/X-SAR is currently scheduled for launch in April 1994. SIR-C is an L-Band and C-Band, multi-polarization spaceborne SAR system developed by NASA/JPL. X- SAR is an X-Band SAR system developed by DARA/ASI. One of the problems involved in calibrating the SIR-C instrument is to make sure that the horizontal (H) and vertical (V) polarized beams are aligned in the azimuth direction, i.e.. that they are pointing in the same direction. This is important if the polarimetric performance specifications for the system are to be met. To solve this problem, we have designed and built a prototype of a low-cost ground receiver capable of recording received power from two antennas, one H-polarized, the other V-polarized. The two signals are mixed to audio then recorded on the left and right stereo channels of a standard audio cassette player. The audio cassette recording can then be played back directly into a Macintosh computer, where it is digitized. Analysis of.

  8. A review of instruments developed to measure food neophobia.

    PubMed

    Damsbo-Svendsen, Marie; Frøst, Michael Bom; Olsen, Annemarie

    2017-06-01

    Food choices are influenced by an individual's attitude towards foods. Food neophobia may be associated with less variety of diets, inadequate nutrient intake and high product failure rate for new food products entering the market. To quantify the extent of these challenges, instruments to measure the food neophobia in different target groups are needed. Several such instruments with significantly different measurement outcomes and procedures have been developed. This review provides an overview and discusses strengths and weaknesses of these instruments. We evaluate strengths and weaknesses of previously developed instruments to measure neophobia and willingness to try unfamiliar foods. Literature was searched through the databases Web of Science and Google Scholar. We identified 255 studies concerning neophobia and willingness to try unfamiliar foods. Of these, 13 studies encompassing 13 instruments to measure neophobia and willingness to try unfamiliar foods were included in the review. Results are summarized and evaluated with a narrative approach. In the 13 instruments to assess neophobia and willingness to try unfamiliar foods, 113 to 16.644 subjects aged 2-65 years were involved, scales with 3-7 response categories were used and behavioral validation tests were included in 6 studies. Several instruments to measure neophobia and willingness to try unfamiliar foods exist. We recommend selecting one or more among the 13 instruments reviewed in this paper to assess relevant aspects of neophobia. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. RECENT DEVELOPMENTS IN HYDROLOGIC INSTRUMENTATION.

    USGS Publications Warehouse

    Latkovich, Vito J.

    1985-01-01

    The availability of space-age materials and implementation of state-of-the-art electronics is making possible the recent developments of hydrologic instrumentation. Material developments include: Synthetic-fiber sounding and tag lines; fiberglass wading rod; polymer (plastic) sheaves, pulleys and sampler components; and polymer (plastic) bucket wheels for current meters. These materials are very cost effective and efficient. Electromechanical and electronic developments and applications include: adaptable data acquisition system; downhole sampler for hazardous substances; current-meter digitizer; hydraulic power/drive system for discharge measurements and water-quality sampling; non-contact water-level sensors; minimum data recorder; acoustic velocity meters, and automated current meter discharge-measurement system.

  10. [Development of new magnetic bead separation and purification instrument].

    PubMed

    Xu, Yingyuan; Chen, Yi

    2014-05-01

    The article describes the development of new magnetic bead separation and purification instrument. The main application of the instrument is to capture tubercle bacillus from sputum. It is a pretreatment instrument and provides a new platform to help doctors to diagnose bacillary phthisis. Not only could it be used for tubercle bacillus capturing, but also for gene, protein and cell separating and purification. Because the controller of the instrument is 16-bit single chip microcomputer, the cost could be greatly reduced and it will be widely used in China.

  11. Development of the Advanced Technology Microwave Sounder (ATMS) for NPOESS C1

    NASA Astrophysics Data System (ADS)

    Brann, C.; Kunkee, D.

    2008-12-01

    The National Polar-orbiting Operational Environmental Satellite System's Advanced Technology Microwave Sounder (ATMS) is planned for flight on the first NPOESS mission (C1) in 2013. The C1 ATMS will be the second instrument of the ATMS series and will provide along with the companion Cross-track Infrared Sounder (CrIS), atmospheric temperature and moisture profiles for NPOESS. The first flight of the ATMS is scheduled in 2010 on the NPOESS Preparatory Project (NPP) satellite, which is an early instrument risk reduction component of the NPOESS mission. This poster will focus on the development of the ATMS for C1 including aspects of the sensor calibration, antenna beam and RF characteristics and scanning. New design aspects of the C1 ATMS, required primarily by parts obsolescence, will also be addressed in this poster.

  12. Development status of the life marker chip instrument for ExoMars

    NASA Astrophysics Data System (ADS)

    Sims, Mark R.; Cullen, David C.; Rix, Catherine S.; Buckley, Alan; Derveni, Mariliza; Evans, Daniel; Miguel García-Con, Luis; Rhodes, Andrew; Rato, Carla C.; Stefinovic, Marijan; Sephton, Mark A.; Court, Richard W.; Bulloch, Christopher; Kitchingman, Ian; Ali, Zeshan; Pullan, Derek; Holt, John; Blake, Oliver; Sykes, Jonathan; Samara-Ratna, Piyal; Canali, Massimiliano; Borst, Guus; Leeuwis, Henk; Prak, Albert; Norfini, Aleandro; Geraci, Ennio; Tavanti, Marco; Brucato, John; Holm, Nils

    2012-11-01

    The Life Marker Chip (LMC) is one of the instruments being developed for possible flight on the 2018 ExoMars mission. The instrument uses solvents to extract organic compounds from samples of martian regolith and to transfer the extracts to dedicated detectors based around the use of antibodies. The scientific aims of the instrument are to detect organics in the form of biomarkers that might be associated with extinct life, extant life or abiotic sources of organics. The instrument relies on a novel surfactant-based solvent system and bespoke, commercial and research-developed antibodies against a number of distinct biomarkers or molecular types. The LMC comprises of a number of subsystems designed to accept up to four discrete samples of martian regolith or crushed rock, implement the solvent extraction, perform microfluidic-based multiplexed antibody-assays for biomarkers and other targets, optically detect the fluorescent output of the assays, control the internal instrument pressure and temperature, in addition to the associated instrument control electronics and software. The principle of operation, the design and the instrument development status as of December 2011 are reported here. The instrument principle can be extended to other configurations and missions as needed.

  13. CHEOPS: status summary of the instrument development

    NASA Astrophysics Data System (ADS)

    Beck, T.; Broeg, C.; Fortier, A.; Cessa, V.; Malvasio, L.; Piazza, D.; Benz, W.; Thomas, N.; Magrin, D.; Viotto, V.; Bergomi, M.; Ragazzoni, R.; Pagano, I.; Peter, G.; Buder, M.; Plesseria, J. Y.; Steller, M.; Ottensamer, R.; Ehrenreich, D.; Van Damme, C.; Isaak, K.; Ratti, F.; Rando, N.; Ngan, I.

    2016-07-01

    CHEOPS (CHaracterizing ExOPlanets Satellite) is the first ESA Small Mission as part of the ESA Cosmic Vision program 2015-2025. The mission was formally adopted in early February 2014 with a planned launch readiness end of 2017. The mission lead is performed in a partnership between Switzerland, led by the University of Bern, and the European Space Agency with important contributions from Austria, Belgium, France, Germany, Hungary, Italy, Portugal, Spain, Sweden, and the United Kingdom. The mission is dedicated to searching for exoplanetary transits by performing ultrahigh precision photometry on bright starts already known to host planets whose mass has been already estimated through ground based observations. The instrument is an optical Ritchey-Chretien telescope of 30 cm clear aperture using a single CCD detector. The optical system is designed to image a de-focused PSF onto the focal plane with very stringent stability and straylight rejection requirements providing a FoV of 0.32 degrees full cone. The system design is adapted to meet the top-level science requirements, which ask for a photometric precision of 20ppm, in 6 hours integration time, on transit measurements of G5 dwarf stars with V-band magnitudes in the range 6≤V≤9 mag. Additionally they ask for a photometric precision of 85 ppm in 3 hours integration time of Neptune-size planets transiting K-type dwarf stars with V-band magnitudes as faint as V=12 mag. Given the demanding schedule and cost constrains, the mission relies mostly on components with flight heritage for the platform as well as for the payload components. Nevertheless, several new developments are integrated into the design as for example the telescope structure and the very low noise, high stability CCD front end electronics. The instrument and mission have gone through critical design review in fall 2015 / spring 2016. This paper describes the current instrument and mission design with a focus on the instrument. It outlines the

  14. High Resolution Mass Spectrometry for future space instrumentation : current development within the French Space Orbitrap Consortium

    NASA Astrophysics Data System (ADS)

    Briois, Christelle; Lebreton, Jean-Pierre; Szopa, Cyril; Thirkell, Laurent; Aradj, Kenzi; Bouabdellah, Abdel; Boukrara, Amirouche; Carrasco, Nathalie; Chalumeau, Gilles; Chapelon, Olivier; Colin, Fabrice; Cottin, Hervé; Engrand, Cécile; Grand, Noel; Kukui, Alexandre; Pennanech, Cyril; Thissen, Roland; Vuitton, Véronique; Zapf, Pascal; Makarov, Alexander

    2014-05-01

    Mass spectrometry has been used for years in space exploration to characterise the chemical composition of solar system bodies and their environment. Because of the harsh constraints imposed to the space probe instruments, their mass resolution is quite limited compared to laboratory instruments, sometimes leading to significant limitations in the treatment of the data collected with this type of instrumentation. Future in situ solar system exploration missions would significantly benefit from High Resolution Mass Spectrometry (HRMS). For a few years, 5 French laboratories (LPC2E, IPAG, LATMOS, LISA, CSNSM) involved in the chemical investigation of solar system bodies formed a Consortium to develop HRMS for future space exploration, based on the use of the Orbitrap technology (C. Briois et al., 2014, to be submitted). This development is carried out in the frame of a Research and Technology (R&T) development programme partly funded by the French Space Agency (CNES). The work is undertaken in close collaboration with the Thermo Fisher Scientific Company, which commercialises Orbitrap-based laboratory instruments. The R&T activities are currently concentrating on the core elements of the Orbitrap analyser that are required to reach a sufficient maturity level for allowing design studies of future space instruments. We are indeed pursuing, within international collaborations, the definition of several instrument concepts based on the core elements that are subject of our R&T programme. In this talk, we briefly discuss science applications for future orbitrap-based HRMS space instruments. We highlight present results of our R&T programme.

  15. Development of low cost instrumentation for non-invasive detection of Helicobacter pylori

    NASA Astrophysics Data System (ADS)

    Kannath, A.; Rutt, H. N.

    2007-02-01

    A new clinical diagnostic instrument for urea breath test (UBT) based non-invasive detection of Helicobacter Pylori is presented here. Its compact and low cost design makes it an economical and commercial alternative for the more expensive Isotope Ratio Mass Spectrometer (IRMS). The instrument is essentially a two channel non-dispersive IR spectrometer that performs high precision ratio measurements of the two carbon isotopomers ( 12CO II and 13CO II) present in exhaled breath. A balanced absorption system configuration was designed where the two channel path lengths would roughly be in the ratio of their concentrations. Equilibrium between the transmitted channel intensities was maintained by using a novel feedback servo mechanism to adjust the length of the 13C channel cell. Extensive computational simulations were performed to study the effect of various possible interferents and their results were considered in the design of the instrument so as to achieve the desired measurement precision of 1%. Specially designed gas cells and a custom made gas filling rig were also developed. A complete virtual interface for both instrument control and data acquisition was implemented in LABVIEW. Initial tests were used to validate the theory and a basic working device was demonstrated.

  16. The SiC hardware of the Sentinel-2 multi spectral instrument

    NASA Astrophysics Data System (ADS)

    Bougoin, Michel; Lavenac, Jérôme

    2017-11-01

    The Sentinel-2 mission is a major part of the GMES (Global Monitoring for Environment and Security) program which has been set up by the European Union, on a joint initiative with the European Space Agency. A pair of identical satellites will observe the earth from a sun-synchronous orbit at 786 km altitude. Astrium is the prime contractor of the satellites and their payload. The MultiSpectral Instrument features a "all-SiC" TMA (Three Mirror Anastygmat) telescope. MSI will provide optical images in 13 spectral bands, in the visible and also the near infra-red range, with a 10 to 60 m resolution and a 290 km wide swath. The Boostec® SiC material is used mainly for its high specific stiffness (Youngs modulus / density) and its high thermal stability (thermal conductivity / coefficient of thermal expansion) which allow to reduce the distortions induced by thermo-elastic stresses. Its high mechanical properties as well as the relevant technology enable to make not only the mirrors but also the structure which holds them and the elements of the focal plane (including some detectors packaging). Due to the required large size, accuracy and shape complexity, developing and manufacturing some of these SiC parts required innovative manufacturing approach. It is reviewed in the present paper.

  17. The Chinese Family Assessment Instrument (C-FAI): Hierarchical Confirmatory Factor Analyses and Factorial Invariance

    ERIC Educational Resources Information Center

    Shek, Daniel T. L.; Ma, Cecilia M. S.

    2010-01-01

    Objective: This paper examines the dimensionality and factorial invariance of the Chinese Family Assessment Instrument (C-FAI) using multigroup confirmatory factor analyses (MCFAs). Method: A total of 3,649 students responded to the C-FAI in a community survey. Results: Results showed that there are five dimensions of the C-FAI (communication,…

  18. Development of an instrument to measure student attitudes toward science fairs

    NASA Astrophysics Data System (ADS)

    Huddleston, Claudia A.

    Science fairs are woven into the very fabric of science instruction in the United States and in other countries. Even though thousands of students participate in science fairs every year, no instrument to measure student attitudes toward partaking in this hands-on learning experience has been fully developed and available for school administrators and teachers to assess the perceived value that current students attribute to participation in science fairs. Therefore, the purpose of this study was to continue the development and refinement of an instrument that measured student attitudes towards science fairs based on an unpublished instrument created by Michael (2005). The instrument developed and tested using 110 students at two different middle schools in southwest Virginia. The instrument consisted of 45 questions. After applying a principal component factor analysis, the instrument was reduced to two domains, enjoyment and value. The internal consistency of the instrument was calculated using Cronbach's alpha and showed good internal consistency of .89 between the two domains. Further analysis was conducted using a Pearson product-moment test and showed a significant positive correlation between enjoyment and value (r = .78). Demographic information was explored concerning the domains using a series of statistical tests, and results revealed no significant differences among race and science fair category. However, a significant difference was found among gender and students who won awards and those who did not. The conclusion was that further development and refinement of the instrument should be conducted.

  19. The development of a survey instrument for community health improvement.

    PubMed Central

    Bazos, D A; Weeks, W B; Fisher, E S; DeBlois, H A; Hamilton, E; Young, M J

    2001-01-01

    OBJECTIVE: To develop a survey instrument that could be used both to guide and evaluate community health improvement efforts. DATA SOURCES/STUDY SETTING: A randomized telephone survey was administered to a sample of about 250 residents in two communities in Lehigh Valley, Pennsylvania in the fall of 1997. METHODS: The survey instrument was developed by health professionals representing diverse health care organizations. This group worked collaboratively over a period of two years to (1) select a conceptual model of health as a foundation for the survey; (2) review relevant literature to identify indicators that adequately measured the health constructs within the chosen model; (3) develop new indicators where important constructs lacked specific measures; and (4) pilot test the final survey to assess the reliability and validity of the instrument. PRINCIPAL FINDINGS: The Evans and Stoddart Field Model of the Determinants of Health and Well-Being was chosen as the conceptual model within which to develop the survey. The Field Model depicts nine domains important to the origins and production of health and provides a comprehensive framework from which to launch community health improvement efforts. From more than 500 potential indicators we identified 118 survey questions that reflected the multiple determinants of health as conceptualized by this model. Sources from which indicators were selected include the Behavior Risk Factor Surveillance Survey, the National Health Interview Survey, the Consumer Assessment of Health Plans Survey, and the SF-12 Summary Scales. The work group developed 27 new survey questions for constructs for which we could not locate adequate indicators. Twenty-five questions in the final instrument can be compared to nationally published norms or benchmarks. The final instrument was pilot tested in 1997 in two communities. Administration time averaged 22 minutes with a response rate of 66 percent. Reliability of new survey questions was

  20. Developing an Instrument for Identifying Secondary Teachers' Beliefs about Education for Sustainable Development in China

    ERIC Educational Resources Information Center

    Yang, Guang; Lam, Chi-Chung; Wong, Ngai-Ying

    2010-01-01

    Education for Sustainable Development (ESD) has been recently recognized as an important area in the new Chinese educational reform. As teachers play a pivotal role, knowing and developing an effective and easy-to-use instrument for tapping teachers' beliefs is essential. This article reports an attempt to develop an instrument with mixed methods.…

  1. [Development of an evaluation instrument for service quality in nursing homes].

    PubMed

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  2. On Using Simulations to Inform Decision Making during Instrument Development

    ERIC Educational Resources Information Center

    Morgan, Grant B.; Moore, Courtney A.; Floyd, Harlee S.

    2018-01-01

    Although content validity--how well each item of an instrument represents the construct being measured--is foundational in the development of an instrument, statistical validity is also important to the decisions that are made based on the instrument. The primary purpose of this study is to demonstrate how simulation studies can be used to assist…

  3. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument.

    PubMed

    LaKind, Judy S; Sobus, Jon R; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J; Arbuckle, Tye E; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P

    2014-12-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument--the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument--for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

    PubMed Central

    LaKind, Judy S.; Sobus, Jon R.; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J.; Arbuckle, Tye E.; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P.

    2015-01-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. PMID:25137624

  5. Developing self-concept instrument for pre-service mathematics teachers

    NASA Astrophysics Data System (ADS)

    Afgani, M. W.; Suryadi, D.; Dahlan, J. A.

    2018-01-01

    This study aimed to develop self-concept instrument for undergraduate students of mathematics education in Palembang, Indonesia. Type of this study was development research of non-test instrument in questionnaire form. A Validity test of the instrument was performed with construct validity test by using Pearson product moment and factor analysis, while reliability test used Cronbach’s alpha. The instrument was tested by 65 undergraduate students of mathematics education in one of the universities at Palembang, Indonesia. The instrument consisted of 43 items with 7 aspects of self-concept, that were the individual concern, social identity, individual personality, view of the future, the influence of others who become role models, the influence of the environment inside or outside the classroom, and view of the mathematics. The result of validity test showed there was one invalid item because the value of Pearson’s r was 0.107 less than the critical value (0.244; α = 0.05). The item was included in social identity aspect. After the invalid item was removed, Construct validity test with factor analysis generated only one factor. The Kaiser-Meyer-Olkin (KMO) coefficient was 0.846 and reliability coefficient was 0.91. From that result, we concluded that the self-concept instrument for undergraduate students of mathematics education in Palembang, Indonesia was valid and reliable with 42 items.

  6. Sample Analysis at Mars Instrument Simulator

    NASA Technical Reports Server (NTRS)

    Benna, Mehdi; Nolan, Tom

    2013-01-01

    The Sample Analysis at Mars Instrument Simulator (SAMSIM) is a numerical model dedicated to plan and validate operations of the Sample Analysis at Mars (SAM) instrument on the surface of Mars. The SAM instrument suite, currently operating on the Mars Science Laboratory (MSL), is an analytical laboratory designed to investigate the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. SAMSIM was developed using Matlab and Simulink libraries of MathWorks Inc. to provide MSL mission planners with accurate predictions of the instrument electrical, thermal, mechanical, and fluid responses to scripted commands. This tool is a first example of a multi-purpose, full-scale numerical modeling of a flight instrument with the purpose of supplementing or even eliminating entirely the need for a hardware engineer model during instrument development and operation. SAMSIM simulates the complex interactions that occur between the instrument Command and Data Handling unit (C&DH) and all subsystems during the execution of experiment sequences. A typical SAM experiment takes many hours to complete and involves hundreds of components. During the simulation, the electrical, mechanical, thermal, and gas dynamics states of each hardware component are accurately modeled and propagated within the simulation environment at faster than real time. This allows the simulation, in just a few minutes, of experiment sequences that takes many hours to execute on the real instrument. The SAMSIM model is divided into five distinct but interacting modules: software, mechanical, thermal, gas flow, and electrical modules. The software module simulates the instrument C&DH by executing a customized version of the instrument flight software in a Matlab environment. The inputs and outputs to this synthetic C&DH are mapped to virtual sensors and command lines that mimic in their structure and connectivity the layout of the instrument harnesses. This module executes

  7. Measuring first-line nurse manager work: instrument: development and testing.

    PubMed

    Cadmus, Edna; Wisniewska, Edyta K

    2013-12-01

    The objective of this study was to develop and test a 1st-line nurse manager (FLNM) work instrument to measure categories of work and frequency of activities. First-line nurse managers have been demonstrated to be key contributors in meeting organizational outcomes and patient and nurse satisfaction. Identifying the work of FLNMs is essential to help in the development of prioritization and sequence. The need for an instrument that can measure and categorize the work of FLNMs is indicated. The author-developed instrument was administered as a pilot study to 173 FLNMs in New Jersey. Descriptive statistics were analyzed, and validity and reliability were measured. Content validity was established through 2 focus groups using 10 FLNMs and conducting a survey of 5 chief nursing officers. Reliability was assessed by 13 of 16 FLNM participants using the test/retest method and quantified using percent agreement within a 10-day period. Those items with 70% agreement or more were identified as reliable and retained on the instrument. The content validity of the instrument is strong; further refinement and testing of the tool are indicated to improve the reliability and generalizability across multiple populations of leaders and settings.

  8. High speed, multi-channel, thermal instrument development in support of HyspIRI-TIR

    NASA Astrophysics Data System (ADS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2011-10-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

  9. Subjective health literacy: Development of a brief instrument for school-aged children.

    PubMed

    Paakkari, Olli; Torppa, Minna; Kannas, Lasse; Paakkari, Leena

    2016-12-01

    The present paper focuses on the measurement of health literacy (HL), which is an important determinant of health and health behaviours. HL starts to develop in childhood and adolescence; hence, there is a need for instruments to monitor HL among younger age groups. These instruments are still rare. The aim of the project reported here was, therefore, to develop a brief, multidimensional, theory-based instrument to measure subjective HL among school-aged children. The development of the instrument covered four phases: item generation based on a conceptual framework; a pilot study ( n = 405); test-retest ( n = 117); and construction of the instrument ( n = 3853). All the samples were taken from Finnish 7th and 9th graders. Initially, 65 items were generated, of which 32 items were selected for the pilot study. After item reduction, the instrument contained 16 items. The test-retest phase produced estimates of stability. In the final phase a 10-item instrument was constructed, referred to as Health Literacy for School-Aged Children (HLSAC). The instrument exhibited a high Cronbach alpha (0.93), and included two items from each of the five predetermined theoretical components (theoretical knowledge, practical knowledge, critical thinking, self-awareness, citizenship). The iterative and validity-driven development process made it possible to construct a brief multidimensional HLSAC instrument. Such instruments are suitable for large-scale studies, and for use with children and adolescents. Validation will require further testing for use in other countries.

  10. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    PubMed

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  11. Interdisciplinary Approach to the Development of Accessible Computer-Administered Measurement Instruments.

    PubMed

    Magasi, Susan; Harniss, Mark; Heinemann, Allen W

    2018-01-01

    Principles of fairness in testing require that all test takers, including people with disabilities, have an equal opportunity to demonstrate their capacity on the construct being measured. Measurement design features and assessment protocols can pose barriers for people with disabilities. Fairness in testing is a fundamental validity issue at all phases in the design, administration, and interpretation of measurement instruments in clinical practice and research. There is limited guidance for instrument developers on how to develop and evaluate the accessibility and usability of measurement instruments. This article describes a 6-stage iterative process for developing accessible computer-administered measurement instruments grounded in the procedures implemented across several major measurement initiatives. A key component of this process is interdisciplinary teams of accessibility experts, content and measurement experts, information technology experts, and people with disabilities working together to ensure that measurement instruments are accessible and usable by a wide range of users. The development of accessible measurement instruments is not only an ethical requirement, it also ensures better science by minimizing measurement bias, missing data, and attrition due to mismatches between the target population and test administration platform and protocols. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. The Process of Developing a Multi-Cell KEMS Instrument

    NASA Technical Reports Server (NTRS)

    Copland, E. H.; Auping, J. V.; Jacobson, N. S.

    2012-01-01

    Multi-cell KEMS offers many advantages over single cell instruments in regard to in-situ temperature calibration and studies on high temperature alloys and oxides of interest to NASA. The instrument at NASA Glenn is a 90 deg magnetic sector instrument originally designed for single cell operation. The conversion of this instrument to a multi-cell instrument with restricted collimation is discussed. For restricted collimation, the 'field aperture' is in the copper plate separating the Knudsen Cell region and the ionizer and the 'source aperture' is adjacent to the ionizer box. A computer controlled x-y table allows positioning of one of the three cells into the sampling region. Heating is accomplished via a Ta sheet element and temperature is measured via an automatic pyrometer from the bottom of the cells. The computer control and data system have been custom developed for this instrument and are discussed. Future improvements are also discussed.

  13. Development and Validation of an Instrument to Assess Youth Motivation to Participate in Career Development Events

    ERIC Educational Resources Information Center

    Knobloch, Neil A.; Brady, Colleen M.; Orvis, Kathryn S.; Carroll, Natalie J.

    2016-01-01

    Career development events develop career and life skills in youth, but limited work has been done to assess the motivation of students who participate in these events. The purpose of this study was to validate an instrument developed to measure youth motivation to participate in career development events. An instrument grounded in expectancy-value…

  14. Development, validity and reliability of the short multidimensional positive mental health instrument.

    PubMed

    Vaingankar, Janhavi Ajit; Subramaniam, Mythily; Abdin, Edimansyah; Picco, Louisa; Chua, Boon Yiang; Eng, Goi Khia; Sambasivam, Rajeswari; Shafie, Saleha; Zhang, Yunjue; Chong, Siow Ann

    2014-06-01

    The 47-item positive mental health (PMH) instrument measures the level of PMH in multiethnic adult Asian populations. This study aimed to (1) develop a short PMH instrument and (2) establish its validity and reliability among the adult Singapore population. Two separate studies were conducted among adult community-dwelling Singapore residents of Chinese, Malay or Indian ethnicity where participants completed self-administered questionnaires. In the first study, secondary data analysis was conducted using confirmatory factor analysis (CFA) to shorten the PMH instrument. In the second study, the newly developed short PMH instrument and other scales were administered to 201 residents to establish its factor structure, validity and reliability. A 20-item short PMH instrument fulfilling a higher-order six-factor structure was developed following secondary analysis. The mean age of the participants in the second study was 41 years and about 53% were women. One item with poor factor loading was further removed to generate a 19-item version of the PMH instrument. CFA demonstrated a first-order six-factor model of the short PMH instrument. The PMH-19 instrument and its subscales fulfilled criterion validity hypotheses. Internal consistency and test-retest reliability of the PMH-19 instrument were high (Cronbach's α coefficient = 0.87; intraclass correlation coefficient = 0.93, respectively). The 19-item PMH instrument is multidimensional, valid and reliable, and most importantly, with its reduced administration time, the short PMH instrument can be used to measure and evaluate PMH in Asian communities.

  15. [Disabled person's satisfaction with health and social care--an internationally developed instrument].

    PubMed

    Kullmann, Lajos; Paulik, Edit

    2011-02-01

    Quality of health and social care is being assessed by largely different methods. Obtaining comparable and valuable data is difficult. Thus, internationally developed instruments have special value. A set of instruments has been developed simultaneously using World Health Organization's instrument development method. One of these is the instrument "Quality of Care and Support for People with Disabilities". Response scales contain five options for physically and three for intellectually disabled persons. Psychometric analysis of the Hungarian instrument version was based on interviews with 151 physically and 166 intellectually disabled persons. Answering rate was high, above 95% with the exception of one item. Internal consistency of the two instrument versions by Cronbach's alpha is 0.845 and 0.745 respectively. Lowest satisfaction was found in the domain "information" in both groups that correlates significantly with health conditions at p < 0.01 and p < 0.05 level respectively. The field trial confirms validity and reliability of the instrument. Its wider use may help the evaluation of satisfaction concerning different components of quality of care, consequently better tailoring of services to needs.

  16. Development of instrument for assessing students’ critical and creative thinking ability

    NASA Astrophysics Data System (ADS)

    Herpiana, R.; Rosidin, U.

    2018-01-01

    The purpose of this study was to develop instruments to measure critical thinking ability and creative students in the topics of physics simple harmonic motion. The research method used was research development with application of procedures including research and data collection, planning, and initial product development. The participants of the study were thirty-four tenth grade students and five physics teachers of physics who were selected randomly from schools in the province of Lampung. The data collected by using test and analyzed in quantitative descriptive. Initial data showed that students’ critical and creative thinking ability were still low and instruments to assess students’ critical thinking skills and creative students was not yet available. Most of assessment conducted focused on memorization. Thus, the researchers developed a draft of instrument in the form of the test description based on criteria that encouraged students’ activity in understanding the concepts, strategies and decision/solution in dealing with problems. The development of the instrument was conducted considering real-world phenomena in the form of pictures and stories, description of the situation, and verbal presentation.

  17. Use of natural diamonds to monitor 14C AMS instrument backgrounds

    NASA Astrophysics Data System (ADS)

    Taylor, R. E.; Southon, John

    2007-06-01

    To examine one component of the instrument-based background in the University of California Keck Carbon Cycle AMS spectrometer, we have obtained measurements on a set of natural diamonds pressed into sample holders. Natural diamond samples (N = 14) from different sources within rock formations with geological ages greatly in excess of 100 Ma yielded a range of currents (∼110-250 μA 12C- where filamentous graphite typically yields ∼150 μA 12C-) and apparent 14C ages (64.9 ± 0.4 ka BP [0.00031 ± 0.00002 fm] to 80.0 ± 1.1 ka BP [0.00005 ± 0.00001 fm]). Six fragments cut from a single diamond exhibited essentially identical 14C values - 69.3 ± 0.5 ka-70.6 ± 0.5 ka BP. The oldest 14C age equivalents were measured on natural diamonds which exhibited the highest current yields.

  18. Recent Developments in PET Instrumentation

    PubMed Central

    Peng, Hao; Levin, Craig S.

    2013-01-01

    Positron emission tomography (PET) is used in the clinic and in vivo small animal research to study molecular processes associated with diseases such as cancer, heart disease, and neurological disorders, and to guide the discovery and development of new treatments. This paper reviews current challenges of advancing PET technology and some of newly developed PET detectors and systems. The paper focuses on four aspects of PET instrumentation: high photon detection sensitivity; improved spatial resolution; depth-of-interaction (DOI) resolution and time-of-flight (TOF). Improved system geometry, novel non-scintillator based detectors, and tapered scintillation crystal arrays are able to enhance the photon detection sensitivity of a PET system. Several challenges for achieving high resolution with standard scintillator-based PET detectors are discussed. Novel detectors with 3-D positioning capability have great potential to be deployed in PET for achieving spatial resolution better than 1 mm, such as cadmium-zinc-telluride (CZT) and position-sensitive avalanche photodiodes (PSAPDs). DOI capability enables a PET system to mitigate parallax error and achieve uniform spatial resolution across the field-of-view (FOV). Six common DOI designs, as well as advantages and limitations of each design, are discussed. The availability of fast scintillation crystals such as LaBr3, and the silicon photomultiplier (SiPM) greatly advances TOF-PET development. Recent instrumentation and initial results of clinical trials are briefly presented. If successful, these technology advances, together with new probe molecules, will substantially enhance the molecular sensitivity of PET and thus increase its role in preclinical and clinical research as well as evaluating and managing disease in the clinic. PMID:20497121

  19. Engine component instrumentation development facility at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.; Buggele, Alvin E.; Lepicovsky, Jan

    1992-01-01

    The Engine Components Instrumentation Development Facility at NASA Lewis is a unique aeronautics facility dedicated to the development of innovative instrumentation for turbine engine component testing. Containing two separate wind tunnels, the facility is capable of simulating many flow conditions found in most turbine engine components. This facility's broad range of capabilities as well as its versatility provide an excellent location for the development of novel testing techniques. These capabilities thus allow a more efficient use of larger and more complex engine component test facilities.

  20. Development and Initial Validation of an Instrument for Human Capital Planning

    ERIC Educational Resources Information Center

    Zula, Kenneth J.; Chermack, Thomas J.

    2008-01-01

    This article reports on development and validation of an instrument for use in human capital approaches for organizational planning. The article describes use of a team of subject matter experts in developing a measure of human capital planning, and use of exploratory factor analysis techniques to validate the resulting instrument. These data were…

  1. Development of a versatile laser light scattering instrument

    NASA Astrophysics Data System (ADS)

    Meyer, William V.; Ansari, Rafat R.

    1990-10-01

    A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

  2. Development of a versatile laser light scattering instrument

    NASA Technical Reports Server (NTRS)

    Meyer, William V.; Ansari, Rafat R.

    1990-01-01

    A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

  3. Measuring the stringency of states' indoor tanning regulations: instrument development and outcomes.

    PubMed

    Woodruff, Susan I; Pichon, Latrice C; Hoerster, Katherine D; Forster, Jean L; Gilmer, Todd; Mayer, Joni A

    2007-05-01

    We sought to describe the development of an instrument to quantify the stringency of state indoor tanning legislation in the United States, and the instrument's psychometric properties. The instrument was then used to rate the stringency of state laws. A 35-item instrument was developed. An overall stringency measure and 9 stringency subscales were developed, including one measuring minors' access to indoor tanning. Stringency measures showed good internal consistency and interrater reliability. In all, 55% of the 50 states and the District of Columbia had any indoor tanning law, and 41% had any law addressing minors' access. Oregon, Illinois, South Carolina, Florida, Indiana, Iowa, and Rhode Island had high overall stringency scores, and Texas and New Hampshire were the most restrictive with regard to minors' access. Measurement of actual enforcement of the laws was not included in this study. The instrument appears to be an easy-to-use, reliable, and valid methodology. Application of the instrument to actual laws showed that, in general, state laws are relatively weak, although there was considerable variability by state.

  4. The Development of an Instrument to Measure Creative Teaching Abilities.

    ERIC Educational Resources Information Center

    Riley, John F.

    The development of an instrument to measure creative teaching abilities, the Creative Teaching Dilemma (CTD), involved three phases. The instrument was constructed and refined, and scoring procedures were outlined. The activities comprising the CTD included defining the teaching dilemma, gathering additional facts, identifying and stating the…

  5. Optical Technologies for UV Remote Sensing Instruments

    NASA Technical Reports Server (NTRS)

    Keski-Kuha, R. A. M.; Osantowski, J. F.; Leviton, D. B.; Saha, T. T.; Content, D. A.; Boucarut, R. A.; Gum, J. S.; Wright, G. A.; Fleetwood, C. M.; Madison, T. J.

    1993-01-01

    Over the last decade significant advances in technology have made possible development of instruments with substantially improved efficiency in the UV spectral region. In the area of optical coatings and materials, the importance of recent developments in chemical vapor deposited (CVD) silicon carbide (SiC) mirrors, SiC films, and multilayer coatings in the context of ultraviolet instrumentation design are discussed. For example, the development of chemically vapor deposited (CVD) silicon carbide (SiC) mirrors, with high ultraviolet (UV) reflectance and low scatter surfaces, provides the opportunity to extend higher spectral/spatial resolution capability into the 50-nm region. Optical coatings for normal incidence diffraction gratings are particularly important for the evolution of efficient extreme ultraviolet (EUV) spectrographs. SiC films are important for optimizing the spectrograph performance in the 90 nm spectral region. The performance evaluation of the flight optical components for the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) instrument, a spectroscopic instrument to fly aboard the Solar and Heliospheric Observatory (SOHO) mission, designed to study dynamic processes, temperatures, and densities in the plasma of the upper atmosphere of the Sun in the wavelength range from 50 nm to 160 nm, is discussed. The optical components were evaluated for imaging and scatter in the UV. The performance evaluation of SOHO/CDS (Coronal Diagnostic Spectrometer) flight gratings tested for spectral resolution and scatter in the DGEF is reviewed and preliminary results on resolution and scatter testing of Space Telescope Imaging Spectrograph (STIS) technology development diffraction gratings are presented.

  6. Development and Validation of a Multicultural Consciousness Instrument

    ERIC Educational Resources Information Center

    Dean, Shannon R.

    2017-01-01

    Developing multiculturally competent citizens is at the forefront of the espoused mission of higher education. The purpose of this study was to develop and validate a self-report instrument to measure traditional-age (18-to 24-year-old) college students' multicultural consciousness (e.g., awareness of self, knowledge of difference, and…

  7. Development of an Instrument to Measure Medical Students' Attitudes toward People with Disabilities

    ERIC Educational Resources Information Center

    Symons, Andrew B.; Fish, Reva; McGuigan, Denise; Fox, Jeffery; Akl, Elie A.

    2012-01-01

    As curricula to improve medical students' attitudes toward people with disabilities are developed, instruments are needed to guide the process and evaluate effectiveness. The authors developed an instrument to measure medical students' attitudes toward people with disabilities. A pilot instrument with 30 items in four sections was administered to…

  8. NASA SMD Airborne Science Capabilities for Development and Testing of New Instruments

    NASA Technical Reports Server (NTRS)

    Fladeland, Matthew

    2015-01-01

    The SMD NASA Airborne Science Program operates and maintains a fleet of highly modified aircraft to support instrument development, satellite instrument calibration, data product validation and earth science process studies. This poster will provide an overview of aircraft available to NASA researchers including performance specifications and modifications for instrument support, processes for requesting aircraft time and developing cost estimates for proposals, and policies and procedures required to ensure safety of flight.

  9. Recent Developments in Instrumentation for Capillary Electrophoresis and Microchip-Capillary Electrophoresis

    PubMed Central

    Felhofer, Jessica L.; Blanes, Lucas; Garcia, Carlos D.

    2010-01-01

    Over the last years there has been an explosion in the number of developments and applications of capillary electrophoresis (CE) and microchip-CE. In part, this growth has been the direct consequence of recent developments in instrumentation associated with CE. This review, which is focused on contributions published in the last five years, is intended to complement the papers presented in this special issue dedicated to Instrumentation and to provide an overview on the general trend and some of the most remarkable developments published in the areas of high voltage power supplies, detectors, auxiliary components, and compact systems. It also includes few examples of alternative uses of and modifications to traditional CE instruments. PMID:20665910

  10. Development of a luminescence planetary surface dating instrument

    NASA Astrophysics Data System (ADS)

    Jain, M.; Lapp, T.; Andersen, M. T.; Hannemann, S.; Murray, A. S.; Duller, G. A. T.; Merrrisen, J.

    2012-04-01

    Luminescence dating (LD) is uniquely positioned for absolute, in-situ, dating of recent (< 1Ma) events on Mars such as the formation of sedimentary landforms, volcanic rocks and salt precipitates. These data can in turn help understand and predict the impact of climate-driven changes on Mars, for example, atmosphere-land interactions, global sand and dust movements and redistribution of volatiles (H2O and CO2). This understanding is critical for any manned mission to Mars and for our understanding of the planetary surface evolution. Despite this potential, the technology transfer from terrestrial to in-situ Martian dating is not trivial. Here we first provide a brief overview of the scientific issues involved in luminescence dating on Mars (e.g. dosimetric characteristics of Martian materials and modelling of cosmic-ray dose rate) and then the technical constraints on an instrument design appropriate for remotely-programmable mobile use on the Martian surface. The challenge is to develop a miniaturised portable luminescence reader that is as sensitive as a laboratory-based instrument and at the same time has sufficient flexibility for fully automated performance. Such an instrument could provide stratigraphic ages if deployed on a rover with a sub-surface drilling capability, or provide a survey of surface chronologies over extensive areas. To this end we have designed and manufactured an 'elegant breadboard' Planetary Surface Dating Instrument (PSDI) in a project supported by ESA. The PSDI is light weight and compact (~1 kg, ~1.4 litres) and has 3 different reloadable sample positions which can be rotated to sit under 3 different optical subunits or an x-ray irradiator. The optical subunits consists of three different detection channels (one red and two UV/blue) each based on a miniature photomultiplier tube, and three types of laser light stimulation sources (two 915 nm, one 530 nm and one 405 nm) that can be operated in continuous-wave or pulsed mode. The

  11. Development of a Mass Spectrometer-based Instrument for Volcanic Gas Monitoring

    NASA Astrophysics Data System (ADS)

    McMurtry, G. M.; Hilton, D. R.; Fischer, T.; Sutton, A. J.; Elias, T.

    2007-05-01

    We have developed and field tested an instrument that is capable of acquiring multiple-species gas chemistry data at active volcanoes and hydrothermal systems. The current prototype consists of a quadrupole mass spectrometer, a series of pumps, valves and control/data logging electronics housed in a corrosion-resistant container. We tested the instrument at the summit of Kilauea volcano in March, 2006, collecting time-series data from a 96°C fumarole (Sulphur Banks) at 15 minute intervals for nearly 3 days. Two temperature probes were utilized, a thermocouple placed in the gas stream and a thermistor which recorded ambient air temperatures inside the instrument housing. Of these, the thermistor produced the more reliable trace, as the thermocouple pegged near 45°C shortly after reaching the fumarole gas composition. This composition was indicated by sharp drops in the instrument response for N2, O2, Ar, and water vapor, and increases in CO2 and SO2 at about 6.5 hours elapsed time. The two most obvious gas/temperature trends in this brief time-series are: (1) sharp discontinuities caused by two of the standard "Giggenbach" bottle sampling interludes (despite some care given not to vent the gas line to atmosphere); and (2) two distinct types of thermal events. The two sampling interruptions caused decreases in temperature, and caused the responses of CO2, N2, O2, Ar and water vapor and the ratio of CO2/He to rise sharply. This appears consistent with contamination by cooler ambient air enriched in CO2 relative to normal air (solfatara air). The two types of thermal events are similar in that both generally show enrichments of SO2 and He, and decreases in CO2/He, whereas the last, much hotter event displays increases in CO2, N2, O2, Ar, and water vapor, in contrast to decreases in these gases during the two former events. The last thermal event correlates with a brief dry period on 17 March, after a previous week of almost continuous rainfall. An interesting

  12. Development and preliminary validation of a leadership competency instrument for existing and emerging allied health professional leaders.

    PubMed

    Ang, Hui-Gek; Koh, Jeremy Meng-Yeow; Lee, Jeffrey; Pua, Yong-Hao

    2016-02-19

    No instruments, to our knowledge, exist to assess leadership competency in existing and emerging allied health professional (AHP) leaders. This paper describes the development and preliminary exploration of the psychometric properties of a leadership competency instrument for existing and emerging AHP leaders and examines (i) its factor structure, (ii) its convergent validity with the Leadership Practices Inventory (LPI), and (iii) its discriminative validity in AHPs with different grades. During development, we included 25 items in the AHEAD (Aspiring leaders in Healthcare-Empowering individuals, Achieving excellence, Developing talents) instrument. A cross-sectional study was then conducted in 106 high-potential AHPs from Singapore General Hospital (34 men and 72 women) of different professional grades (49 principal-grade AHPs, 41 senior-grade AHPs, and 16 junior-grade AHPs) who completed both AHEAD and LPI instruments. Exploratory factor analysis was used to test the theoretical structure of AHEAD. Spearman correlation analysis was performed to evaluate the convergent validity of AHEAD with LPI. Using proportional odds regression models, we evaluated the association of grades of AHPs with AHEAD and LPI. To assess discriminative validity, the c-statistics - a measure of discrimination - were derived from these ordinal models. As theorized, factor analysis suggested a two-factor solution, where "skills" and "values" formed separate factors. Internal consistency of AHEAD was excellent (α-values > 0.88). Total and component AHEAD and LPI scores correlated moderately (Spearman ρ-values, 0.37 to 0.58). The c-index for discriminating between AHP grades was higher for AHEAD than for the LPI (0.76 vs. 0.65). The factorial structure of AHEAD was generally supported in our study. AHEAD showed convergent validity with the LPI and outperformed the LPI in terms of discriminative validity. These results provide initial evidence for the use of AHEAD to assess leadership

  13. Smart Payload Development for High Data Rate Instrument Systems

    NASA Technical Reports Server (NTRS)

    Pingree, Paula J.; Norton, Charles D.

    2007-01-01

    This slide presentation reviews the development of smart payloads instruments systems with high data rates. On-board computation has become a bottleneck for advanced science instrument and engineering capabilities. In order to improve the computation capability on board, smart payloads have been proposed. A smart payload is a Localized instrument, that can offload the flight processor of extensive computing cycles, simplify the interfaces, and minimize the dependency of the instrument on the flight system. This has been proposed for the Mars mission, Mars Atmospheric Trace Molecule Spectroscopy (MATMOS). The design of this system is discussed; the features of the Virtex-4, are discussed, and the technical approach is reviewed. The proposed Hybrid Field Programmable Gate Array (FPGA) technology has been shown to deliver breakthrough performance by tightly coupling hardware and software. Smart Payload designs for instruments such as MATMOS can meet science data return requirements with more competitive use of available on-board resources and can provide algorithm acceleration in hardware leading to implementation of better (more advanced) algorithms in on-board systems for improved science data return

  14. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    DTIC Science & Technology

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  15. Instrument Control (iC) – An Open-Source Software to Automate Test Equipment

    PubMed Central

    Pernstich, K. P.

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming. PMID:26900522

  16. NASA Instrument Cost Model for Explorer-Like Mission Instruments (NICM-E)

    NASA Technical Reports Server (NTRS)

    Habib-Agahi, Hamid; Fox, George; Mrozinski, Joe; Ball, Gary

    2013-01-01

    NICM-E is a cost estimating relationship that supplements the traditional NICM System Level CERs for instruments flown on NASA Explorer-like missions that have the following three characteristics: 1) fly on Class C missions, 2) major development led and performed by universities or research foundations, and 3) have significant level of inheritance.

  17. The Need, Development, and Validation of the Innovation Test Instrument

    ERIC Educational Resources Information Center

    Wheadon, Jacob; Wright, Geoff A.; West, Richard E.; Skaggs, Paul

    2017-01-01

    This study discusses the need, development, and validation of the Innovation Test Instrument (ITI). This article outlines how the researchers identified the content domain of the assessment and created test items. Then, it describes initial validation testing of the instrument. The findings suggest that the ITI is a good first step in creating an…

  18. The development of an instrument to assess chemistry perceptions

    NASA Astrophysics Data System (ADS)

    Wells, Raymond R.

    The instrument, developed in this study, attempted to correct the deficiencies of previous instruments. Statements of belief and opinion can be validly included under the construct of chemistry perceptions. Further, statements that might be better characterized as science attitudes, math attitudes, or attitudes toward a specific course or program were not included. Eliminating statements of math anxiety and test anxiety insured that responses to statements of anxiety were perceptions of anxiety solely related to chemistry. The results of the expert judges' responses to the Validation of Proposed Perception Statements forms were detailed to establish construct and content validity. The nature of Likert scale construction and calculation of internal consistency also supported the validity of the instrument. A pilot Chemistry Perception Questionnaire (CPQ) was then constructed based on agreement of the appropriate subscale and mean importance of the perception statements. The pilot CPQ results were subjected to an item analysis based on three sets of statistics: the frequency of each response and the percentage of respondents making each response for each perception statement, the mean and standard deviations for each item, and the item discrimination index which correlated the item scores with the subscale scores. With no zero or negative correlations to the subscale scores, it was not necessary to replace any of the perception statements contained in the pilot instrument. Therefore, the piloted Chemistry Perception Questionnaire became the final instrument. Factor analysis confirmed the multidimensionality of the instrument. The instrument was administered twice with a separation interval of approximately one month in order to perform a test-retest reliability analysis. One hundred and forty-one pairs were matched and results detailed. The correlation between forms, for the total instrument, was 0.9342. The mean coefficient alpha, for the total instrument, was 0

  19. Jonathan W. Amy and the Amy Facility for Instrumentation Development.

    PubMed

    Cooks, R Graham

    2017-05-16

    This Perspective describes the unique Jonathan Amy Facility for Chemical Instrumentation in the Department of Chemistry at Purdue University, tracing its history and mode of operation. It also describes aspects of the career of its namesake and some of his insights which have been central to analytical instrumentation development, improvement, and utilization, both at Purdue and nationally.

  20. Perception of Competence in Middle School Physical Education: Instrument Development and Validation

    ERIC Educational Resources Information Center

    Scrabis-Fletcher, Kristin; Silverman, Stephen

    2010-01-01

    Perception of Competence (POC) has been studied extensively in physical activity (PA) research with similar instruments adapted for physical education (PE) research. Such instruments do not account for the unique PE learning environment. Therefore, an instrument was developed and the scores validated to measure POC in middle school PE. A…

  1. Development of the instruments for the Gamma Ray Observatory

    NASA Technical Reports Server (NTRS)

    Madden, J. J.; Kniffen, D. A.

    1986-01-01

    The Gamma Ray Observatory (GRO) is to be launched in 1988 by the STS. The GRO will feature four very large instruments: the Oriented Scintillation Spectrometer Experiment (OSSE), the Imaging Compton Telescope (COMPTEL), the Energetic Gamma Ray Experiment Telescope (EGRET) and the Burst and Transient Source Experiment (BATSE). The instruments weigh from 900-1200 kg each, and required the development of specialized lifting and dolly devices to permit their assembly, manipulation and testing. The GRO is intended a{s a tool for studying discrete celestial objects such as black holes, neutron stars and other gamma-ray emitting objects, scanning for nucleosynthesis processes, mapping the Galaxy and other, high energy galaxies in terms of gamma rays, searching for cosmological effects and observing gamma ray bursts. The instruments will be sensitive from the upper end mof X-rya wavelengths to the highest energies possible. Details of the hardware and performance specifications of each of the instruments are discussed.

  2. Design, development, and testing of the DCT Cassegrain instrument support assembly

    NASA Astrophysics Data System (ADS)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  3. [The Basel Screening Instrument for Psychosis (BSIP): development, structure, reliability and validity].

    PubMed

    Riecher-Rössler, A; Aston, J; Ventura, J; Merlo, M; Borgwardt, S; Gschwandtner, U; Stieglitz, R-D

    2008-04-01

    Early detection of psychosis is of growing clinical importance. So far there is, however, no screening instrument for detecting individuals with beginning psychosis in the atypical early stages of the disease with sufficient validity. We have therefore developed the Basel Screening Instrument for Psychosis (BSIP) and tested its feasibility, interrater-reliability and validity. Aim of this paper is to describe the development and structure of the instrument, as well as to report the results of the studies on reliability and validity. The instrument was developed based on a comprehensive search of literature on the most important risk factors and early signs of schizophrenic psychoses. The interraterreliability study was conducted on 24 psychiatric cases. Validity was tested based on 206 individuals referred to our early detection clinic from 3/1/2000 until 2/28/2003. We identified seven categories of relevance for early detection of psychosis and used them to construct a semistructured interview. Interrater-reliability for high risk individuals was high (Kappa .87). Predictive validity was comparable to other, more comprehensive instruments: 16 (32 %) of 50 individuals classified as being at risk for psychosis by the BSIP have in fact developed frank psychosis within an follow-up period of two to five years. The BSIP is the first screening instrument for the early detection of psychosis which has been validated based on transition to psychosis. The BSIP is easy to use by experienced psychiatrists and has a very good interrater-reliability and predictive validity.

  4. New developments in instrumentation at the W. M. Keck Observatory

    NASA Astrophysics Data System (ADS)

    Adkins, Sean M.; Armandroff, Taft E.; Fitzgerald, Michael P.; Johnson, James; Larkin, James E.; Lewis, Hilton A.; Martin, Christopher; Matthews, Keith Y.; Prochaska, J. X.; Wizinowich, Peter

    2014-07-01

    The W. M. Keck Observatory continues to develop new capabilities in support of our science driven strategic plan which emphasizes leadership in key areas of observational astronomy. This leadership is a key component of the scientific productivity of our observing community and depends on our ability to develop new instrumentation, upgrades to existing instrumentation, and upgrades to supporting infrastructure at the observatory. In this paper we describe the as measured performance of projects completed in 2014 and the expected performance of projects currently in the development or construction phases. Projects reaching completion in 2014 include a near-IR tip/tilt sensor for the Keck I adaptive optics system, a new center launch system for the Keck II laser guide star facility, and NIRES, a near-IR Echelle spectrograph for the Keck II telescope. Projects in development include a new seeing limited integral field spectrograph for the visible wavelength range called the Keck Cosmic Web Imager, a deployable tertiary mirror for the Keck I telescope, upgrades to the spectrograph detector and the imager of the OSIRIS instrument, and an upgrade to the telescope control systems on both Keck telescopes.

  5. Development and Validation of an Instrument to Measure University Students' Biotechnology Attitude

    NASA Astrophysics Data System (ADS)

    Erdogan, Mehmet; Özel, Murat; Uşak, Muhammet; Prokop, Pavol

    2009-06-01

    The impact of biotechnologies on peoples' everyday lives continuously increases. Measuring young peoples' attitudes toward biotechnologies is therefore very important and its results are useful not only for science curriculum developers and policy makers, but also for producers and distributors of genetically modified products. Despite of substantial number of instruments which focused on measuring student attitudes toward biotechnology, a majority of them were not rigorously validated. This study deals with the development and validation of an attitude questionnaire toward biotechnology. Detailed information on development and validation process of the instrument is provided. Data gathered from 326 university students provided evidence for the validity and reliability of the new instrument which consists of 28 attitude items on a five point likert type scale. It is believed that the instrument will serve as a valuable tool for both instructors and researchers in science education to assess students' biotechnology attitudes.

  6. Recent Developments in Positron Emission Tomography (PET) Instrumentation

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.

  7. Career Assessment: Recently Developed Instruments Useful for School-to-Work Programs.

    ERIC Educational Resources Information Center

    Kapes, Jerome T.; Martinez, Linda

    This document describes 32 recently developed career assessment instruments that have been deemed useful for school-to-work programs. The following instruments are among those profiled: Ability Explorer; Adult Measure of Essential Skills; Aptitude Interest Inventory; Ashland Interest Assessment; Barriers to Employment Success Inventory; Basic…

  8. Design and development of control unit and software for the ADFOSC instrument of the 3.6 m Devasthal optical telescope

    NASA Astrophysics Data System (ADS)

    Kumar, T. S.

    2016-08-01

    In this paper, we describe the details of control unit and GUI software for positioning two filter wheels, a slit wheel and a grism wheel in the ADFOSC instrument. This is a first generation instrument being built for the 3.6 m Devasthal optical telescope. The control hardware consists of five electronic boards based on low cost 8-bit PIC microcontrollers and are distributed over I2C bus. The four wheels are controlled by four identical boards which are configured in I2C slave mode while the fifth board acts as an I2C master for sending commands to and receiving status from the slave boards. The master also communicates with the interfacing PC over TCP/IP protocol using simple ASCII commands. For moving the wheels stepper motors along with suitable amplifiers have been employed. Homing after powering ON is achieved using hall effect sensors. By implementing distributed control units having identical design modularity is achieved enabling easier maintenance and upgradation. A GUI based software for commanding the instrument is developed in Microsoft Visual C++. For operating the system during observations the user selects normal mode while the engineering mode is available for offering additional flexibility and low level control during maintenance and testing. A detailed time-stamped log of commands, status and errors are continuously generated. Both the control unit and the software have been successfully tested and integrated with the ADFOSC instrument.

  9. Advanced CO2 removal process control and monitor instrumentation development

    NASA Technical Reports Server (NTRS)

    Heppner, D. B.; Dalhausen, M. J.; Klimes, R.

    1982-01-01

    A progam to evaluate, design and demonstrate major advances in control and monitor instrumentation was undertaken. A carbon dioxide removal process, one whose maturity level makes it a prime candidate for early flight demonstration was investigated. The instrumentation design incorporates features which are compatible with anticipated flight requirements. Current electronics technology and projected advances are included. In addition, the program established commonality of components for all advanced life support subsystems. It was concluded from the studies and design activities conducted under this program that the next generation of instrumentation will be greatly smaller than the prior one. Not only physical size but weight, power and heat rejection requirements were reduced in the range of 80 to 85% from the former level of research and development instrumentation. Using a microprocessor based computer, a standard computer bus structure and nonvolatile memory, improved fabrication techniques and aerospace packaging this instrumentation will greatly enhance overall reliability and total system availability.

  10. Developing evaluation instrument based on CIPP models on the implementation of portfolio assessment

    NASA Astrophysics Data System (ADS)

    Kurnia, Feni; Rosana, Dadan; Supahar

    2017-08-01

    This study aimed to develop an evaluation instrument constructed by CIPP model on the implementation of portfolio assessment in science learning. This study used research and development (R & D) method; adapting 4-D by the development of non-test instrument, and the evaluation instrument constructed by CIPP model. CIPP is the abbreviation of Context, Input, Process, and Product. The techniques of data collection were interviews, questionnaires, and observations. Data collection instruments were: 1) the interview guidelines for the analysis of the problems and the needs, 2) questionnaire to see level of accomplishment of portfolio assessment instrument, and 3) observation sheets for teacher and student to dig up responses to the portfolio assessment instrument. The data obtained was quantitative data obtained from several validators. The validators consist of two lecturers as the evaluation experts, two practitioners (science teachers), and three colleagues. This paper shows the results of content validity obtained from the validators and the analysis result of the data obtained by using Aikens' V formula. The results of this study shows that the evaluation instrument based on CIPP models is proper to evaluate the implementation of portfolio assessment instruments. Based on the experts' judgments, practitioners, and colleagues, the Aikens' V coefficient was between 0.86-1,00 which means that it is valid and can be used in the limited trial and operational field trial.

  11. Development of an alpha scattering instrument for heavy element detection in surface materials

    NASA Technical Reports Server (NTRS)

    Turkevich, A. L.; Economou, T.; Blume, E.; Anderson, W.

    1974-01-01

    The development and characteristics of a portable instrument for detecting and measuring the amounts of lead in painted surfaces are discussed. The instrument is based on the ones used with the alpha scattering experiment on the Surveyor lunar missions. The principles underlying the instrument are described. It is stated that the performance tests of the instrument were satisfactory.

  12. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less

  13. The Development of Two Self-Assessment Work Value Instruments.

    ERIC Educational Resources Information Center

    Boyle, John R.

    In response to input from the employment and training community, the Department of Labor's Assessment and Research Development Program (ARDP) and its state partners have developed two self-assessment work value instruments to be incorporated into career exploration and counseling programs. Computerized multiple rank-order and paper-and-pencil…

  14. Lean Management as an Instrument of Sustainable Development of Enterprises

    NASA Astrophysics Data System (ADS)

    Sikora, Marcin; Kwiatkowski, Maciej; Prosół, Hanna; Nowicka, Daria; Lorenc, Karolina; Pham, Laurena

    2016-03-01

    The aim of the paper is to present the philosophy of Lean Management as an instrument of improving sustainable management of enterprises. The article presents the origins, characteristics of the broadly understood concept of Lean Management and describes the idea of Sustainable Development (SD). At the same time implications for the application and development of the instruments which operationalize the assumptions of SD at the level of enterprises are discussed. The paper specifies those areas of functioning of contemporary companies in which Lean Management can be implemented and compares them with the features of traditional management in particular subjects.

  15. An integrated assessment instrument: Developing and validating instrument for facilitating critical thinking abilities and science process skills on electrolyte and nonelectrolyte solution matter

    NASA Astrophysics Data System (ADS)

    Astuti, Sri Rejeki Dwi; Suyanta, LFX, Endang Widjajanti; Rohaeti, Eli

    2017-05-01

    The demanding of assessment in learning process was impact by policy changes. Nowadays, assessment is not only emphasizing knowledge, but also skills and attitudes. However, in reality there are many obstacles in measuring them. This paper aimed to describe how to develop integrated assessment instrument and to verify instruments' validity such as content validity and construct validity. This instrument development used test development model by McIntire. Development process data was acquired based on development test step. Initial product was observed by three peer reviewer and six expert judgments (two subject matter experts, two evaluation experts and two chemistry teachers) to acquire content validity. This research involved 376 first grade students of two Senior High Schools in Bantul Regency to acquire construct validity. Content validity was analyzed used Aiken's formula. The verifying of construct validity was analyzed by exploratory factor analysis using SPSS ver 16.0. The result show that all constructs in integrated assessment instrument are asserted valid according to content validity and construct validity. Therefore, the integrated assessment instrument is suitable for measuring critical thinking abilities and science process skills of senior high school students on electrolyte solution matter.

  16. Development of the Online Assessment of Athletic Training Education (OAATE) Instrument

    ERIC Educational Resources Information Center

    Carr, W. David; Frey, Bruce B.; Swann, Elizabeth

    2009-01-01

    Objective: To establish the validity and reliability of an online assessment instrument's items developed to track educational outcomes over time. Design and Setting: A descriptive study of the validation arguments and reliability testing of the assessment items. The instrument is available to graduating students enrolled in entry-level Athletic…

  17. Innovative technology in hearing instruments: matching needs in the developing world.

    PubMed

    McPherson, Bradley

    2011-12-01

    Hearing instrument technology research is almost entirely focused on the projected needs of the consumer market in the developed world. However, two thirds of the world's population with hearing impairment live in developing countries and this proportion will increase in future, given present demographic trends. In developing regions, amplification and other hearing health needs may differ from those in industrialized nations, for cultural, health, or economic reasons. World Health Organization estimates indicate that at present only a small percentage of individuals in developing countries who are in need of amplification have access to hearing aid provision. New technologies, such as trainable hearing aids, advanced noise reduction algorithms, feedback reduction circuitry, nano coatings for hearing aid components, and innovative power options, may offer considerable potential benefits, both for individuals with hearing impairment in developing countries and for those who provide hearing health care services in these regions. This article considers the possible supporting role of innovative hearing instrument technologies in the provision of affordable hearing health care services in developing countries and highlights the need for research that considers the requirements of the majority of the world population in need of hearing instrument provision.

  18. Effect of finishing instrumentation using NiTi hand files on volume, surface area and uninstrumented surfaces in C-shaped root canal systems.

    PubMed

    Amoroso-Silva, P; Alcalde, M P; Hungaro Duarte, M A; De-Deus, G; Ordinola-Zapata, R; Freire, L G; Cavenago, B C; De Moraes, I G

    2017-06-01

    To assess the effect of 90°-oscillatory instrumentation with hand files on several morphological parameters (volume, surface area and uninstrumented surface) in C-shaped root canals after instrumentation using a single-file reciprocation system (Reciproc; VDW, Munich, Germany) and a Self-Adjusting File System (SAF; ReDent Nova, Ra'anana, Israel). Twenty mandibular second molars with C-shaped canals and C1 canal configurations were divided into two groups (n = 10) and instrumented with Reciproc and SAF instruments. A size 30 NiTi hand K-file attached to a 90°-oscillatory motion handpiece was used as final instrumentation in both groups. The specimens were scanned using micro-computed tomography after all procedures. Volume, surface area increase and uninstrumented root canal surface were analysed using CTAn software (Bruker-microCT, Kontich, Belgium). Also, the uninstrumented root canal surface was calculated for each canal third. All values were compared between groups using the Mann-Whitney test and within groups using the Wilcoxon's signed-rank test. Instrumentation with Reciproc significantly increased canal volume compared with instrumentation with SAF. Additionally, the canal volumes were significantly increased after 90°-oscillatory instrumentation (between and within group comparison; (P < 0.05)). Regarding the increase in surface area after all instrumentation protocols, statistical analysis only revealed significant differences in the within groups comparison (P < 0.05). Reciproc and SAF instrumentation yielded an uninstrumented root canal surface of 28% and 34%, respectively, which was not significantly different (P > 0.05). Final oscillatory instrumentation significantly reduced the uninstrumented root canal surface from 28% to 9% (Reciproc) and from 34% to 15% (SAF; P < 0.05). The apical and middle thirds exhibited larger uninstrumented root canal surfaces after the first instrumentation that was significantly reduced after oscillatory

  19. Development and evaluation of the Korean Health Literacy Instrument.

    PubMed

    Kang, Soo Jin; Lee, Tae Wha; Paasche-Orlow, Michael K; Kim, Gwang Suk; Won, Hee Kwan

    2014-01-01

    The purpose of this study is to develop and validate the Korean Health Literacy Instrument, which measures the capacity to understand and use health-related information and make informed health decisions in Korean adults. In Phase 1, 33 initial items were generated to measure functional, interactive, and critical health literacy with prose, document, and numeracy tasks. These items included content from health promotion, disease management, and health navigation contexts. Content validity assessment was conducted by an expert panel, and 11 items were excluded. In Phase 2, the 22 remaining items were administered to a convenience sample of 292 adults from community and clinical settings. Exploratory factor and item difficulty and discrimination analyses were conducted and four items with low discrimination were deleted. In Phase 3, the remaining 18 items were administered to a convenience sample of 315 adults 40-64 years of age from community and clinical settings. A confirmatory factor analysis was performed to test the construct validity of the instrument. The Korean Health Literacy Instrument has a range of 0 to 18. The mean score in our validation study was 11.98. The instrument exhibited an internal consistency reliability coefficient of 0.82, and a test-retest reliability of 0.89. The instrument is suitable for screening individuals who have limited health literacy skills. Future studies are needed to further define the psychometric properties and predictive validity of the Korean Health Literacy Instrument.

  20. Developing an Iranian ELT Context-Specific Grit Instrument.

    PubMed

    Ebadi, Saman; Weisi, Hiwa; Khaksar, Zahra

    2018-03-06

    Grit as an interesting and significant topic in psychology has been associated with better study habits and higher grades through perseverance and passion for long term goals. The only available measurement instrument of grit (Duckworth et al. in J Personal Soc Psychol 92:1087-1101, 2007) is general both in terms of its subject matter and context. Thus, this study aims to develop and validate an English as a foreign language (EFL) grit instrument whose items are specific to EFL context to obtain a more detailed view of its components for Iranian EFL learners, and to tap on other grit related factors in the EFL context. A four component model of EFL grit was developed through reviewing the existing literature and exploring EFL experts' perspectives. This tentative theoretical model of EFL grit encompasses overarching construct of effort including the following main components: Trying hard to learn English (THLE) having interest in learning English (ILE) practicing a lot in order to learn English (PLE) and having goal for learning English (HGLE). The model was then cross checked against the results of the interviews, and evolved into a scenario-based, 5 point Likert-scale EFL grit instrument. It was later operationalized by an instrument consisting of 26 items, i.e. 6 items for each component plus 2 items for themes 1 and 3. The piloting and testing of the tentative model through exploratory and confirmatory data analyses on a sample of 306 EFL learners indicated the reliability of 0.833 and an acceptable validity. The findings called for a more meaningful interpretation of the concept of grit in relation to Iranian EFL context and offered new insights for higher education administrators considering student academic performance.

  1. From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale

    ERIC Educational Resources Information Center

    Thomas, Eileen

    2011-01-01

    The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…

  2. Personal-Interpersonal Competence Assessment: A Self-Report Instrument for Student Development

    ERIC Educational Resources Information Center

    Seal, Craig R.; Miguel, Krystal; Alzamil, Abdulaziz; Naumann, Stefanie E.; Royce-Davis, Joanna; Drost, Donald

    2015-01-01

    The purpose of this paper is to assess the internal consistency of a revised instrument, the Personal-Interpersonal Competence Assessment (PICA); derived from the earlier Social Emotional Development Instrument (SED-I). There were three primary rationales for the revision. First, and most importantly, to better align the operational factors with…

  3. Sentinel-5 instrument: status of design, performance, and development

    NASA Astrophysics Data System (ADS)

    Gühne, T.; Keim, C.; Bartsch, P.; Weiß, S.; Melf, M.; Seefelder, W.

    2017-09-01

    The Sentinel-5 instrument is currently under development by a consortium led by Airbus Defence and Space in the frame of the European Union Copernicus program. It is a customer furnished item to the MetOp Second Generation satellite platform, which will provide operational meteorological data for the coming decades. Mission objective of the Sentinel-5 is to monitor the composition of the Earth atmosphere for Copernicus Atmosphere Services by taking measurements of trace gases and aerosols impacting air quality and climate with high resolution and daily global coverage. Therefore the Sentinel-5 provides five dispersive spectrometers covering the UV-VIS (270…500 nm), NIR (685 …773 nm) and SWIR (1590…1675 and 2305…2385 nm) spectral bands with resolutions <=1nm. Spatially the Sentinel-5 provides a 108° field of view with a ground sampling of 7.5 x 7 km2 at Nadir. The development program is post PDR and the build-up of the industrial team is finalised. We report on the instrument architecture and design derived from the driving requirements, the predicted instrument performance, and the general status of the program.

  4. Patient Evaluation of Emotional Comfort Experienced (PEECE): developing and testing a measurement instrument

    PubMed Central

    Lester, L; Bulsara, C; Petterson, A; Bennett, K; Allen, E; Joske, D

    2017-01-01

    Objectives The Patient Evaluation of Emotional Comfort Experienced (PEECE) is a 12-item questionnaire which measures the mental well-being state of emotional comfort in patients. The instrument was developed using previous qualitative work and published literature. Design Instrument development. Setting Acute Care Public Hospital, Western Australia. Participants Sample of 374 patients. Interventions A multidisciplinary expert panel assessed the face and content validity of the instrument and following a pilot study, the psychometric properties of the instrument were explored. Main outcome measures Exploratory and confirmatory factor analysis assessed the underlying dimensions of the PEECE instrument; Cronbach's α was used to determine the reliability; κ was used for test–retest reliability of the ordinal items. Results 2 factors were identified in the instrument and named ‘positive emotions’ and ‘perceived meaning’. A greater proportion of male patients were found to report positive emotions compared with female patients. The instrument was found to be feasible, reliable and valid for use with inpatients and outpatients. Conclusions PEECE was found to be a feasible instrument for use with inpatient and outpatients, being easily understood and completed. Further psychometric testing is recommended. PMID:28122833

  5. Development of a radiology faculty appraisal instrument by using critical incident interviewing.

    PubMed

    Collins, J; Albanese, M A; Thakor, S K; Propeck, P A; Scanlan, K A

    1997-12-01

    To develop a valid and reliable radiology faculty appraisal instrument based on scientific methods. Fifteen radiology residents participated in critical incident interviewing. During a 1-hour interview, a resident was asked to describe five incidents each of effective and ineffective faculty behavior. Two investigators independently listened to the tape-recorded interviews, and two different investigators sorted the incidents into broad categories. A faculty appraisal instrument was developed by listing similar incidents under broad categories. A five-point rating scale was applied to each item. Content validity was assessed by resident and faculty critique of the appraisal instrument. A total of 168 incidents of faculty behavior were generated. The frequency with which similar incidents were reported was recorded. The most common behaviors reported were related to staff expertise and teaching. Interjudge reliability was good, as determined by computing K indices of agreement (overall K = 0.59). There was good agreement regarding instrument content validity among residents but not among faculty. Residents supported the use of the new appraisal instrument, but further tests of validity and reliability and faculty acceptance of the instrument will determine its usefulness as a tool for monitoring faculty teaching performance and making decisions regarding faculty promotion.

  6. Individual Entrepreneurial Orientation: Development of a Measurement Instrument

    ERIC Educational Resources Information Center

    Bolton, Dawn Langkamp; Lane, Michelle D.

    2012-01-01

    Purpose: The purpose of this paper is to develop a measurement instrument for individual entrepreneurial orientation to be used to measure the entrepreneurial orientation of students and other individuals. Design/methodology/approach: A measure of Individual Entrepreneurial Orientation (IEO) was generated, validated, and then tested on 1,100…

  7. Developing an Instrument to Assess Higher Education Leadership.

    ERIC Educational Resources Information Center

    Montez, Joni

    An instrument was developed to assess the construct of higher education leadership from discrete innate (possessed) and extrinsic (directed toward others) points of view. Dimensions of the latent construct of higher education leadership were identified, and their content and the relationships between their indicators were "mapped" according to the…

  8. Development of a Measurement Instrument to Assess Students' Electrolyte Conceptual Understanding

    ERIC Educational Resources Information Center

    Lu, Shanshan; Bi, Hualin

    2016-01-01

    To assess students' conceptual understanding levels and diagnose alternative frameworks of the electrolyte concept, a measurement instrument was developed using the Rasch model. This paper reports the use of the measurement instrument to assess 559 students from grade 10 to grade 12 in two cities. The results provided both diagnostic and summative…

  9. Vocational Education Students' Generic Working Life Competencies: Developing a Self-Assessment Instrument

    ERIC Educational Resources Information Center

    Kyndt, Eva; Janssens, Ine; Coertjens, Liesje; Gijbels, David; Donche, Vincent; Van Petegem, Peter

    2014-01-01

    The current study reports on the process of developing a self-assessment instrument for vocational education students' generic working life competencies. The instrument was developed based on a competence framework and in close collaboration with several vocational education teachers and intermediary organisations offering various human…

  10. Development and preliminary testing of a self-rating instrument to measure self-directed learning ability of nursing students.

    PubMed

    Cheng, Su-Fen; Kuo, Chien-Lin; Lin, Kuan-Chia; Lee-Hsieh, Jane

    2010-09-01

    With the growing trend of preparing students for lifelong learning, the theory of self-directed learning (SDL) has been increasingly applied in the context of higher education. In order to foster lifelong learning, abilities among nursing students, faculties need to have an appropriate instrument to measure the SDL abilities of nursing students. The objectives of this study were to develop an instrument to measure the SDL abilities of nursing students and to test the validity and reliability of this instrument. This study was conducted in 4 phases. In Phase 1, based on a review of the literature, the researchers developed an instrument to measure SDL. In Phase 2, two rounds of the Delphi study were conducted, to determine the content validity of the instrument. In Phase 3, a convenience sample of 1072 nursing students from two representative schools across three different types of nursing programs were recruited to test the construct validity of the Self-Directed Learning Instrument (SDLI). Finally, in Phase 4, the internal consistency and reliability of the instrument were tested. The resulting SDLI consists of 20 items across the following four domains: learning motivation, planning and implementing, self-monitoring, and interpersonal, communication. The final model in confirmatory factor analysis revealed that this 20-item SDLI indicated a good fit of the model. The value of Cronbach's alpha for the total scale was .916 and for the four domains were .801, .861, .785, and .765, respectively. The SDLI is a valid and reliable instrument for identifying student SDL abilities. It is available to students in nursing and similar medical programs to evaluate their own SDL. This scale may also enable nursing faculty to assess students' SDL status, design better lesson plans and curricula, and, implement appropriate teaching strategies for nursing students in order to foster the growth of lifelong learning abilities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  11. Instrument Description: The Total Solar Irradiance Monitor on the FY-3C Satellite, an Instrument with a Pointing System

    NASA Astrophysics Data System (ADS)

    Wang, Hongrui; Wang, Yupeng; Ye, Xin; Yang, Dongjun; Wang, Kai; Li, Huiduan; Fang, Wei

    2017-01-01

    The Total Solar Irradiance Monitor (TSIM) onboard the nadir Feng Yun-3C (FY-3C) satellite provides measurements of the total solar irradiance with accurate solar tracking and sound thermal stability of its heat sink. TSIM/FY-3C mainly consists of the pointing system, the radiometer package, the thermal control system, and the electronics. Accurate solar tracking is achieved by the pointing system, which greatly improves the science data quality when compared with the previous TSIM/FY-3A and TSIM/FY-3B. The total solar irradiance (TSI) is recorded by TSIM/FY-3C about 26 times each day, using a two-channel radiometer package. One channel is used to perform routine observation, and the other channel is used to monitor the degradation of the cavity detector in the routine channel. From the results of the ground test, the incoming irradiance is measured by the routine channel (AR1) with a relative uncertainty of 592 ppm. A general description of the TSIM, including the instrument modules, uncertainty evaluation, and its operation, is given in this article.

  12. Using qualitative methods to develop a contextually tailored instrument: Lessons learned.

    PubMed

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C

    2015-01-01

    To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations.

  13. A comparative review of measurement instruments to inform and evaluate effectiveness of disability inclusive development.

    PubMed

    Goujon, Nicolas; Devine, Alexandra; Baker, Sally M; Sprunt, Beth; Edmonds, Tanya J; Booth, Jennifer K; Keeffe, Jill E

    2014-01-01

    A review of existing measurement instruments was conducted to examine their suitability to measure disability prevalence and assess quality of life, protection of disability rights and community participation by people with disabilities, specifically within the context of development programs in low and middle-income countries. From a search of PubMed and the grey literature, potentially relevant measurement instruments were identified and examined for their content and psychometric properties, where possible. Criteria for inclusion were: based on the WHO's International Classification of Functioning Disability and Health (ICF), used quantitative methods, suitable for population-based studies of disability inclusive development in English and published after 1990. Characteristics of existing instruments were analysed according to components of the ICF and quality of life domains. Ten instruments were identified and reviewed according to the criteria listed above. Each version of instruments was analysed separately. Only three instruments included a component on quality of life. Domains from the ICF that were addressed by some but not all instruments included the environment, technology and communication. The measurement instruments reviewed covered the range of elements required to measure disability-inclusion within development contexts. However no single measurement instrument has the capacity to measure both disability prevalence and changes in quality of life according to contemporary disability paradigms. The review of measurement instruments supports the need for developing an instrument specifically intended to measure disability inclusive practice within development programs. Implications for Rehabilitation Surveys and tools are needed to plan disability inclusive development. Existing measurement tools to determine prevalence of disability, wellbeing, rights and access to the community were reviewed. No single validated tool exists for population

  14. Attitudes to Educational Issues: Development of an Instrument.

    ERIC Educational Resources Information Center

    Lemke, Jay L.; And Others

    To obtain a test which could be used for the collection, analysis, and interpretation of data on teachers' attitudes toward contemporary educational issues, the Attitudes to Educational Issues instrument (AEI) was developed. Statements were written in five-choice Likert format to express attitudes toward these six educational issues: (1)…

  15. Development and validation of instrument for ergonomic evaluation of tablet arm chairs

    PubMed Central

    Tirloni, Adriana Seára; dos Reis, Diogo Cunha; Bornia, Antonio Cezar; de Andrade, Dalton Francisco; Borgatto, Adriano Ferreti; Moro, Antônio Renato Pereira

    2016-01-01

    The purpose of this study was to develop and validate an evaluation instrument for tablet arm chairs based on ergonomic requirements, focused on user perceptions and using Item Response Theory (IRT). This exploratory study involved 1,633 participants (university students and professors) in four steps: a pilot study (n=26), semantic validation (n=430), content validation (n=11) and construct validation (n=1,166). Samejima's graded response model was applied to validate the instrument. The results showed that all the steps (theoretical and practical) of the instrument's development and validation processes were successful and that the group of remaining items (n=45) had a high consistency (0.95). This instrument can be used in the furniture industry by engineers and product designers and in the purchasing process of tablet arm chairs for schools, universities and auditoriums. PMID:28337099

  16. The Extreme Ultraviolet Explorer science instruments development - Lessons learned

    NASA Technical Reports Server (NTRS)

    Malina, Roger F.; Battel, S.

    1991-01-01

    The science instruments development project for the Extreme Ultraviolet Explorer (EUVE) satellite is reviewed. Issues discussed include the philosophical basis of the program, the establishment of a tight development team, the approach to planning and phasing activities, the handling of the most difficult technical problems, and the assessment of the work done during the preimplemntation period of the project.

  17. The development of a high-capacity instrument module heat transport system, appendixes

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Data sheets provide temperature requirements for 82 individual instruments that are under development or planned for grouping on a space platform or pallet. The scientific objectives of these instrument packages are related to solar physics, space plasma physics, astronomy, high energy astrophysics, resources observations, environmental observations, materials processing, and life sciences. System specifications are given for a high capacity instrument module heat transport system to be used with future payloads.

  18. Prediction of sickness absence: development of a screening instrument

    PubMed Central

    Duijts, S F A; Kant, IJ; Landeweerd, J A; Swaen, G M H

    2006-01-01

    Objectives To develop a concise screening instrument for early identification of employees at risk for sickness absence due to psychosocial health complaints. Methods Data from the Maastricht Cohort Study on “Fatigue at Work” were used to identify items to be associated with an increased risk of sickness absence. The analytical procedures univariate logistic regression, backward stepwise linear regression, and multiple logistic regression were successively applied. For both men and women, sum scores were calculated, and sensitivity and specificity rates of different cut‐off points on the screening instrument were defined. Results In women, results suggested that feeling depressed, having a burnout, being tired, being less interested in work, experiencing obligatory change in working days, and living alone, were strong predictors of sickness absence due to psychosocial health complaints. In men, statistically significant predictors were having a history of sickness absence, compulsive thinking, being mentally fatigued, finding it hard to relax, lack of supervisor support, and having no hobbies. A potential cut‐off point of 10 on the screening instrument resulted in a sensitivity score of 41.7% for women and 38.9% for men, and a specificity score of 91.3% for women and 90.6% for men. Conclusions This study shows that it is possible to identify predictive factors for sickness absence and to develop an instrument for early identification of employees at risk for sickness absence. The results of this study increase the possibility for both employers and policymakers to implement interventions directed at the prevention of sickness absence. PMID:16698807

  19. Cobalt: Development and Maturation of GN&C Technologies for Precision Landing

    NASA Technical Reports Server (NTRS)

    Carson, John M.; Restrepo, Carolina; Seubert, Carl; Amzajerdian, Farzin

    2016-01-01

    The CoOperative Blending of Autonomous Landing Technologies (COBALT) instrument is a terrestrial test platform for development and maturation of guidance, navigation and control (GN&C) technologies for precision landing. The project is developing a third-generation Langley Research Center (LaRC) navigation doppler lidar (NDL) for ultra-precise velocity and range measurements, which will be integrated and tested with the Jet Propulsion Laboratory (JPL) lander vision system (LVS) for terrain relative navigation (TRN) position estimates. These technologies together provide precise navigation knowledge that is critical for a controlled and precise touchdown. The COBALT hardware will be integrated in 2017 into the GN&C subsystem of the Xodiac rocket-propulsive vertical test bed (VTB) developed by Masten Space Systems, and two terrestrial flight campaigns will be conducted: one open-loop (i.e., passive) and one closed-loop (i.e., active).

  20. Instrument developments and recent scientific highlights at the J-NSE

    NASA Astrophysics Data System (ADS)

    Ivanova, Oxana; Pasini, Stefano; Monkenbusch, Michael; Holderer, Olaf

    2017-06-01

    The J-NSE neutron spin echo spectrometer faces now 10 years of successful user operation at the FRM II research reactor at the Heinz Maier-Leibnitz Zentrum (MLZ). We present scientific highlights and instrumental developments of the last decade, for example the development of grazing incidence neutron spin echo spectroscopy (GINSES) at the J-NSE and investigations of the dynamics at solid-liquid interfaces with this new option. Polymers in confinement have been a prominent topic, as well as the internal dynamics of proteins. The scientific questions also triggered instrumental developments such as a new polarizer and a new neutron guide concept. Finally, the future of the J-NSE will be addressed with a short presentation of the current upgrade program with superconducting main coils with reduced intrinsic field integral inhomogeneity.

  1. Quality of prenatal care questionnaire: instrument development and testing.

    PubMed

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  2. Development of performance assessment instrument based contextual learning for measuring students laboratory skills

    NASA Astrophysics Data System (ADS)

    Susilaningsih, E.; Khotimah, K.; Nurhayati, S.

    2018-04-01

    The assessment of laboratory skill in general hasn’t specific guideline in assessment, while the individual assessment of students during a performance and skill in performing laboratory is still not been observed and measured properly. Alternative assessment that can be used to measure student laboratory skill is use performance assessment. The purpose of this study was to determine whether the performance assessment instrument that the result of research can be used to assess basic skills student laboratory. This research was conducted by the Research and Development. The result of the data analysis performance assessment instruments developed feasible to implement and validation result 62.5 with very good categories for observation sheets laboratory skills and all of the components with the very good category. The procedure is the preliminary stages of research and development stages. Preliminary stages are divided in two, namely the field studies and literature studies. The development stages are divided into several parts, namely 1) development of the type instrument, 2) validation by an expert, 3) a limited scale trial, 4) large-scale trials and 5) implementation of the product. The instrument included in the category of effective because 26 from 29 students have very high laboratory skill and high laboratory skill. The research of performance assessment instrument is standard and can be used to assess basic skill student laboratory.

  3. Development of a surface topography instrument for automotive textured steel plate

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang

    2010-08-01

    The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.

  4. Novel Developments in Instrumentation for PET Imaging

    NASA Astrophysics Data System (ADS)

    Karp, Joel

    2013-04-01

    Advances in medical imaging, in particular positron emission tomography (PET), have been based on technical developments in physics and instrumentation that have common foundations with detection systems used in other fields of physics. New detector materials are used in PET systems that maximize efficiency, timing characteristics and robustness, and which lead to improved image quality and quantitative accuracy for clinical imaging. Time of flight (TOF) techniques are now routinely used in commercial PET scanners that combine physiological imaging with anatomical imaging provided by x-ray computed tomography. Using new solid-state photo-sensors instead of traditional photo-multiplier tubes makes it possible to combine PET with magnetic resonance imaging which is a significant technical challenge, but one that is creating new opportunities for both research and clinical applications. An overview of recent advances in instrumentation, such as TOF and PET/MR will be presented, along with examples of imaging studies to demonstrate the impact on patient care and basic research of diseases.

  5. FPGA based control system for space instrumentation

    NASA Astrophysics Data System (ADS)

    Di Giorgio, Anna M.; Cerulli Irelli, Pasquale; Nuzzolo, Francesco; Orfei, Renato; Spinoglio, Luigi; Liu, Giovanni S.; Saraceno, Paolo

    2008-07-01

    The prototype for a general purpose FPGA based control system for space instrumentation is presented, with particular attention to the instrument control application software. The system HW is based on the LEON3FT processor, which gives the flexibility to configure the chip with only the necessary HW functionalities, from simple logic up to small dedicated processors. The instrument control SW is developed in ANSI C and for time critical (<10μs) commanding sequences implements an internal instructions sequencer, triggered via an interrupt service routine based on a HW high priority interrupt.

  6. [Development of Nanotechnology for X-Ray Astronomy Instrumentation

    NASA Technical Reports Server (NTRS)

    Schattenburg, Mark L.

    2004-01-01

    This Research Grant provides support for development of nanotechnology for x-ray astronomy instrumentation. MIT has made significant progress in several development areas. In the last year we have made considerable progress in demonstrating the high-fidelity patterning and replication of x-ray reflection gratings. We developed a process for fabricating blazed gratings in silicon with extremely smooth and sharp sawtooth profiles, and developed a nanoimprint process for replication. We also developed sophisticated new fixturing for holding thin optics during metrology without causing distortion. We developed a new image processing algorithm for our Shack-Hartmann tool that uses Zernike polynomials. This has resulted in much more accurate and repeatable measurements on thin optics.

  7. Alberta Learning: Early Development Instrument Pilot Project Evaluation.

    ERIC Educational Resources Information Center

    Meaney, Wanda; Harris-Lorenze, Elayne

    The Early Development Instrument (EDI) was designed by McMaster University to measure the outcomes of childrens early years as they influence their readiness to learn at school. The EDI was piloted in several Canadian cities in recent years through two national initiatives. Building on these initiatives, Alberta Learning piloted the EDI as a…

  8. On Convergence of Development Costs and Cost Models for Complex Spaceflight Instrument Electronics

    NASA Technical Reports Server (NTRS)

    Kizhner, Semion; Patel, Umeshkumar D.; Kasa, Robert L.; Hestnes, Phyllis; Brown, Tammy; Vootukuru, Madhavi

    2008-01-01

    Development costs of a few recent spaceflight instrument electrical and electronics subsystems have diverged from respective heritage cost model predictions. The cost models used are Grass Roots, Price-H and Parametric Model. These cost models originated in the military and industry around 1970 and were successfully adopted and patched by NASA on a mission-by-mission basis for years. However, the complexity of new instruments recently changed rapidly by orders of magnitude. This is most obvious in the complexity of representative spaceflight instrument electronics' data system. It is now required to perform intermediate processing of digitized data apart from conventional processing of science phenomenon signals from multiple detectors. This involves on-board instrument formatting of computational operands from row data for example, images), multi-million operations per second on large volumes of data in reconfigurable hardware (in addition to processing on a general purpose imbedded or standalone instrument flight computer), as well as making decisions for on-board system adaptation and resource reconfiguration. The instrument data system is now tasked to perform more functions, such as forming packets and instrument-level data compression of more than one data stream, which are traditionally performed by the spacecraft command and data handling system. It is furthermore required that the electronics box for new complex instruments is developed for one-digit watt power consumption, small size and that it is light-weight, and delivers super-computing capabilities. The conflict between the actual development cost of newer complex instruments and its electronics components' heritage cost model predictions seems to be irreconcilable. This conflict and an approach to its resolution are addressed in this paper by determining the complexity parameters, complexity index, and their use in enhanced cost model.

  9. The Conceptual Framework for the Development of a Mathematics Performance Assessment Instrument.

    ERIC Educational Resources Information Center

    Lane, Suzanne

    1993-01-01

    A conceptual framework is presented for the development of the Quantitative Understanding: Amplifying Student Achievement and Reasoning (QUASAR) Cognitive Assessment Instrument (QCAI) that focuses on the ability of middle-school students to problem solve, reason, and communicate mathematically. The instrument will provide programatic rather than…

  10. Development of the Levey-Nowak Embedded Librarian Presence Instrument: A Preliminary Study

    ERIC Educational Resources Information Center

    Levey, Janet A.; Nowak, Karen L.

    2015-01-01

    A cross-sectional descriptive design was used to examine the initial psychometric properties and feasibility of the newly developed Levey-Nowak Embedded Librarian Presence Instrument. The instrument was structured by a literature review identifying reoccurring concepts of presence, helpfulness, confidence, and collaboration within the embedded…

  11. Using qualitative methods to develop a contextually tailored instrument: Lessons learned

    PubMed Central

    Lee, Haeok; Kiang, Peter; Kim, Minjin; Semino-Asaro, Semira; Colten, Mary Ellen; Tang, Shirley S.; Chea, Phala; Peou, Sonith; Grigg-Saito, Dorcas C.

    2015-01-01

    Objective: To develop a population-specific instrument to inform hepatitis B virus (HBV) and human papilloma virus (HPV) prevention education and intervention based on data and evidence obtained from the targeted population of Khmer mothers reflecting their socio-cultural and health behaviors. Methods: The principles of community-based participatory research (CBPR) guided the development of a standardized survey interview. Four stages of development and testing of the survey instrument took place in order to inform the quantitative health survey used to collect data in stage five of the project. This article reports only on Stages 1-4. Results: This process created a new quantitative measure of HBV and HPV prevention behavior based on the revised Network Episode Model and informed by the targeted population. The CBPR method facilitated the application and translation of abstract theoretical ideas of HBV and HPV prevention behavior into culturally-relevant words and expressions of Cambodian Americans (CAs). Conclusions: The design of an instrument development process that accounts for distinctive socio-cultural backgrounds of CA refugee/immigrant women provides a model for use in developing future health surveys that are intended to aid minority-serving health care professionals and researchers as well as targeted minority populations. PMID:27981114

  12. The design and development of a third generation OSEE instrument

    NASA Technical Reports Server (NTRS)

    Perey, D. F.; Yost, W. T.; Stone, F. D.; Welch, C. S.; Scales, E.; Gasser, E. S.; Joe, E.; Goodman, T.; Pascual, X.; Hefner, B.

    1995-01-01

    Optically Stimulated Electron Emission (OSEE) has been used to quantify surface contamination in the aerospace community. As advances are made towards the understanding of OSEE, it is desirable to incorporate technological advances with succeeding generations of instrumentation, so that improvements in the practical application of OSEE may be disseminated among the user community. Several studies undertaken by Yost, Welch, Abedin and others have expanded the knowledge base related to the underlying principles of OSEE. The conclusions of these studies, together with inputs from the user community were the foundation upon which the development of a third generation OSEE instrument was based. This manuscript describes the significant improvements incorporated into a third generation OSEE instrument as well as the elements unique to its design.

  13. Developing Sight-Reading Skills on Mallet Percussion Instruments

    ERIC Educational Resources Information Center

    Fidyk, Steve

    2009-01-01

    Sight-reading while playing a mallet instrument can present serious obstacles for the developing percussionist. Many young players who have solid snare drum technique usually cite fear of playing the wrong note as the number-one hurdle to overcome in order to begin making real progress. Greg Byrne, associate director of bands at the University of…

  14. Development and Psychometric Properties of the Instrumental Activities of Daily Living: Compensation Scale

    PubMed Central

    Schmitter-Edgecombe, Maureen; Parsey, Carolyn; Lamb, Richard

    2014-01-01

    The Instrumental Activities of Daily Living – Compensation (IADL-C) scale was developed to capture early functional difficulties and to quantify compensatory strategy use that may mitigate functional decline in the aging population. The IADL-C was validated in a sample of cognitively healthy older adults (N=184) and individuals with mild cognitive impairment (MCI; N=92) and dementia (N=24). Factor analysis and Rasch item analysis led to the 27-item IADL-C informant questionnaire with four functional domain subscales (money and self-management, home daily living, travel and event memory, and social skills). The subscales demonstrated good internal consistency (Rasch reliability 0.80 to 0.93) and test-retest reliability (Spearman coefficients 0.70 to 0.91). The IADL-C total score and subscales showed convergent validity with other IADL measures, discriminant validity with psychosocial measures, and the ability to discriminate between diagnostic groups. The money and self management subscale showed notable difficulties for individuals with MCI, whereas difficulties with home daily living became more prominent for dementia participants. Compensatory strategy use increased in the MCI group and decreased in the dementia group. PMID:25344901

  15. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    NASA Astrophysics Data System (ADS)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  16. Development of an audit instrument for nursing care plans in the patient record

    PubMed Central

    Bjorvell, C; Thorell-Ekstrand, I; Wredling, R

    2000-01-01

    Objectives—To develop, validate, and test the reliability of an audit instrument that measures the extent to which patient records describe important aspects of nursing care. Material—Twenty records from each of three hospital wards were collected and audited. The auditors were registered nurses with a knowledge of nursing documentation in accordance with the VIPS model—a model designed to structure nursing documentation. (VIPS is an acronym formed from the Swedish words for wellbeing, integrity, prevention, and security.) Methods—An audit instrument was developed by determining specific criteria to be met. The audit questions were aimed at revealing the content of the patient for nursing assessment, nursing diagnosis, planned interventions, and outcome. Each of the 60 records was reviewed by the three auditors independently and the reliability of the instrument was tested by calculating the inter-rater reliability coefficient. Content validity was tested by using an expert panel and calculating the content validity ratio. The criterion related validity was estimated by the correlation between the score of the Cat-ch-Ing instrument and the score of an earlier developed and used audit instrument. The results were then tested by using Pearson's correlation coefficient. Results—The new audit instrument, named Cat-ch-Ing, consists of 17 questions designed to judge the nursing documentation. Both quantity and quality variables are judged on a rating scale from zero to three, with a maximum score of 80. The inter-rater reliability coefficients were 0.98, 0.98, and 0.92, respectively for each group of 20 records, the content validity ratio ranged between 0.20 and 1.0 and the criterion related validity showed a significant correlation of r = 0.68 (p< 0.0001, 95% CI 0.57 to 0.76) between the two audit instruments. Conclusion—The Cat-ch-Ing instrument has proved to be a valid and reliable audit instrument for nursing records when the VIPS model is used as the

  17. Training With Curved Laparoscopic Instruments in Single-Port Setting Improves Performance Using Straight Instruments: A Prospective Randomized Simulation Study.

    PubMed

    Lukovich, Peter; Sionov, Valery Ben; Kakucs, Timea

    2016-01-01

    Lately single-port surgery is becoming a widespread procedure, but it is more difficult than conventional laparoscopy owing to the lack of triangulation. Although, these operations are also possible with standard laparoscopic instruments, curved instruments are being developed. The aims of the study were to identify the effect of training on a box trainer in single-port setting on the quality of acquired skills, and transferred with the straight and curved instruments for the basic laparoscopic tasks, and highlight the importance of a special laparoscopic training curriculum. A prospective study on a box trainer in single-port setting was conducted using 2 groups. Each group performed 2 tasks on the box trainer in single-port setting. Group-S used conventional straight laparoscopic instruments, and Group-C used curved laparoscopic instruments. Learning curves were obtained by daily measurements recorded in 7-day sessions. On the last day, the 2 groups changed instruments between each other. 1st Department of Surgery, Semmelweis University of Medicine from Budapest, Hungary, a university teaching hospital. In all, 20 fifth-year medical students were randomized into 2 groups. None of them had any laparoscopic or endoscopic experience. Participation was voluntary. Although Group-S performed all tasks significantly faster than Group-C on the first day, the difference proved to be nonsignificant on the last day. All participants achieved significantly shorter task completion time on the last day than on the first day, regardless of the instrument they used. Group-S showed improvement of 63.5%, and Group-C 69.0% improvement by the end of the session. After swapping the instruments, Group-S reached significantly higher task completion time with curved instruments, whereas Group-C showed further progression of 8.9% with straight instruments. Training with curved instruments in a single-port setting allows for a better acquisition of skills in a shorter period. For this

  18. The FASES instrument development and experiment preparation for the ISS

    NASA Astrophysics Data System (ADS)

    Picker, Gerold; Gollinger, Klaus; Greger, Ralf; Dettmann, Jan; Winter, Josef; Dewandre, Thierry; Castiglione, Luigi; Vincent-Bonnieu, Sebastien; Liggieri, Libero; Clausse, Daniele; Antoni, Mickael

    The FASES experiments target the investigation of the stability of emulsions. The main objec-tives are the study of the surfactant adsorption at the liquid / liquid interfaces, the interaction of the droplets as well as the behaviour of the liquid film between nearby drops. Particular focus is given to the dynamic droplet evolution during emulsion destabilisation. The results of the experiments shall support development of methods for the modelling of droplet size distri-butions, which are important to many industries using stable emulsions like food production, cosmetics and pharmaceutics or unstable emulsions as required for applications in waste water treatment or crude oil recovery. The development of the experimental instrumentation was initiated in 2002. The flight instru-ment hardware development was started in 2004 and finally the flight unit was completed in 2009. Currently the final flight preparation is proceeding targeting a launch to the International Space Station (ISS) with Progress 39P in September 2010. The experiment setup of the instrument is accommodated in a box type insert called Experiment Container (EC), which will be installed in the Fluid Science Laboratory part of the European Columbus module of the ISS. The EC is composed of two diagnostics instruments for the investigation of transparent and opaque liquid emulsion. The transparent emulsions will be subject to the experiment called "Investigations on drop/drop interactions in Transparent Emulsions" (ITEM). The opaque emulsion samples will be studied in the experiment called "Investigations on concentrated or opaque Emulsions and on Phase Inversions" (EMPI). The thermal conditioning unit (TCU) allows performing homogeneous thermalization, tem-perature sweeps, emulsion preparation by stirrer, and optical diagnostics with a scanning mi-croscope. The objective of the instrument is the 3D reconstruction of the emulsion droplet distribution in the liquid matrix in terms of the droplet sizes

  19. Voice-Related Patient-Reported Outcome Measures: A Systematic Review of Instrument Development and Validation

    PubMed Central

    Daniero, James J.; Hovis, Kristen L.; Sathe, Nila; Jacobson, Barbara; Penson, David F.; Feurer, Irene D.; McPheeters, Melissa L.

    2017-01-01

    Purpose The purpose of this study was to perform a comprehensive systematic review of the literature on voice-related patient-reported outcome (PRO) measures in adults and to evaluate each instrument for the presence of important measurement properties. Method MEDLINE, the Cumulative Index of Nursing and Allied Health Literature, and the Health and Psychosocial Instrument databases were searched using relevant vocabulary terms and key terms related to PRO measures and voice. Inclusion and exclusion criteria were developed in consultation with an expert panel. Three independent investigators assessed study methodology using criteria developed a priori. Measurement properties were examined and entered into evidence tables. Results A total of 3,744 studies assessing voice-related constructs were identified. This list was narrowed to 32 PRO measures on the basis of predetermined inclusion and exclusion criteria. Questionnaire measurement properties varied widely. Important thematic deficiencies were apparent: (a) lack of patient involvement in the item development process, (b) lack of robust construct validity, and (c) lack of clear interpretability and scaling. Conclusions PRO measures are a principal means of evaluating treatment effectiveness in voice-related conditions. Despite their prominence, available PRO measures have disparate methodological rigor. Care must be taken to understand the psychometric and measurement properties and the applicability of PRO measures before advocating for their use in clinical or research applications. PMID:28030869

  20. Development of a language screening instrument for Swedish 4-year-olds.

    PubMed

    Lavesson, Ann; Lövdén, Martin; Hansson, Kristina

    2018-05-01

    The Swedish Program for health surveillance of preschool children includes screening of language and communication abilities. One important language screening is carried out at age 4 years as part of a general screening conducted by health nurses at child health centres. The instruments presently in use for this screening mainly focus on expressive phonology. This may result in both over-referral of children with phonological difficulties and under-referral of children with language disorders (LDs), involving difficulties with vocabulary, grammar and/or language comprehension. Previous research has proposed non-word repetition as a clinical marker for LD. It has also been found that higher predictive power is achieved when non-word repetition is combined with the assessment of lexical/semantic skills. Taking these findings into account, the construction of a language screening instrument may yield more adequate referrals to speech-language therapists (SLTs). To construct a new standardized language screening instrument for 4-year-olds and to test its properties. An instrument was developed and revised after piloting. A population of 352 children was screened at the regular 4-year check-up by 11 health nurses. The final sample consisted of 328 children aged 46-53 months (23% multilingual). Children performing below a preliminary cut-off were referred to an SLT (n = 52). Five SLTs carried out an assessment on average within 5 weeks using a gold standard language test battery. Children who screened negatively were followed up with a parent questionnaire at age 5;6. Thirty-one true-positives and 11 false-positives were identified after SLT assessment. A further six children were identified as false-negatives (two through referral to an SLT and four through parent questionnaire at age 5;6). A receiver-operating characteristics curve with a C statistic of .94 was calculated. Based on optimal cut-off, the sensitivity of the screening instrument was found to be .84, and

  1. Development of a low-cost mini environment chamber for precision instruments

    NASA Astrophysics Data System (ADS)

    Feng, Jian; Li, Rui-Jun; He, Ya-Xiong; Fan, Kuang-Chao

    2016-01-01

    The wavelength of laser interferometer used widely in precision measurement instrument is affected by the refractive index of surrounding air, which depends on the temperature, relative humidity (RH) and air pressure. A low-cost mini chamber based on the natural convection principle with high-precision temperature-controlled and humidity-suppressed is proposed in this paper. The main chamber is built up by acrylic walls supported by aluminum beam column and are tailored according to the required space. A thin layer of vacuum insulation panel (VIP) with an ultralow thermal conductivity coefficient is adhered around the walls so as to prevent heat exchange with room air. A high-precision temperature sensor measuring the temperature near the instrument's measuring point provides a feedback signal to a proportional-integral-derivative (PID) controller. Several thermoelectric coolers uniformly arranged on the ceiling of the chamber to cool the air inside the chamber directly without any air supply system, yielding a vibration-free cooling system. A programmable power supply is used as the driver for the coolers to generate different cooling capacities. The down-flowing cool air and the up-flowing hot air form a natural convection, and the air temperature in the chamber gradually becomes stable and finally reaches the temperature set by the PID controller. Recycled desiccant contained silica gels that have high affinity for water is used as a drying agent. Experimental results show that in about two hours the system's steady state error is 0.003°C on average, and the variation range is less than ± 0.02°C when the set temperature is 20°C, the RH is reduced from 66% to about 48%. This innovative mini chamber has the advantages of low-cost, vibration-free, and low energy-consumption. It can be used for any micro/nanomeasurement instrument and its volume can be customer-designed.

  2. Development of optical near-infrared spectroscopy instruments for human skin sebum measurement

    NASA Astrophysics Data System (ADS)

    Msabbri, A. R.; Mohamad, M.; MatJafri, M. Z.; Omar, A. F.

    2014-05-01

    There are many techniques and instruments that are currently available to give better results for measuring the quality of human skin. In this study, two non-invasive spectroscopy instruments have been used namely NIRQuest spectrometer and ASD FieldSpec® 3 Spectroradiometer. Both of these spectroscopy instruments were used to find the correlation technique with the commercial instruments (DermaLab® USB Sebum Module). Initially an experiment was conducted to find intensities peak of the absorption of oleic acid as a part of sebum composition. From the spectra peak of the absorbance, the wavelength will be determined. Next step was to measure the reflectance of human skin sebum by using two spectroscopic instruments. The analysis will carry on at the wavelength that have been chosen from the previous study and also from the wavelength of the fatty acid to find the best wavelength that contribute in sebum composition. From several analyses, the wavelengths that contribute in sebum were 1208, 1414, 1726, and 1758 nm that obtained the value of R2 0.8444 for NIRQuest Spectrometer and 0.8532 for ASD FieldSpec® 3 Spectroradiometer. For future research this non- invasive techniques can be used in dermatology field for the use of various skin analysis. Besides that, the less wavelength used is an advantage to develop instruments with less amount of wavelength sensor. It can reduce the cost of development.

  3. EDITORIAL Smart materials, multifunctional composites, and morphing structures: selected papers from the 20th International Conference on Adaptive Structures and Technologies (ICAST 2009) Smart materials, multifunctional composites, and morphing structures: selected papers from the 20th International Conference on Adaptive Structures and Technologies (ICAST 2009)

    NASA Astrophysics Data System (ADS)

    Liao, Wei-Hsin

    2010-12-01

    The 20th International Conference on Adaptive Structures and Technologies (ICAST) was held on 20-22 October 2009 in Hong Kong. This special section of Smart Materials and Structures is derived from the research papers presented at the conference. Of the 106 papers presented at the conference, 11 papers were reviewed and accepted for this special section, following the regular review procedures of the journal. This special section is focused on smart materials, multifunctional composites, and applications on morphing structures. Smart materials. Smart materials are the foundation of adaptive structures and intelligent systems. The development of new materials will lead to significant improvement in various applications. Three articles are focused on the fabrication of new materials and investigation of their behaviors: Barium strontium zirconate titanate ((Ba1-xSrx)(ZrxTi1-x)O3; BSZT, x = 0.25 and 0.75) ceramics with a highly crystalline structure were fabricated using the combustion technique. The microstructure of BSZT powders exhibited an almost-spherical morphology and had a porous agglomerated form. Polyaniline (PANI)/clay nanoparticles with unique core-shell structure were synthesized via Pickering emulsion polymerization. By dispersing PANI/clay nanoparticles in silicone oil, the ER fluid was made. Magnetic field effects were investigated on the deposition rate and surface morphology of chromium nitride coatings deposited by magnetron sputtering for superior hardness, excellent wear and oxidation resistance. The surface morphology of chromium nitride films was also examined by a scanning electron microscope (SEM). Multifunctional composites. Composites are made from two or more constituent materials so they can combine the best properties of different materials. Five papers deal with fabrication, testing, and modeling of various multifunctional composites: A new active structural fiber (ASF) was fabricated by coating a single carbon fiber with a concentric

  4. Development of a near-infrared spectroscopy instrument for applications in urology.

    PubMed

    Macnab, Andrew J; Stothers, Lynn

    2008-10-01

    Near infrared spectroscopy (NIRS) is an established technology using photons of light in the near infrared spectrum to monitor changes in tissue of naturally occurring chromophores, including oxygenated and deoxygenated hemoglobin. Technology and methodology have been validated for measurement of a range of physiologic parameters. NIRS has been applied successfully in urology research; however current instruments are designed principally for brain and muscle study. To describe development of a NIRS instrument specifically designed for monitoring changes in chromophore concentration in the bladder detrusor in real time, to facilitate research to establish the role of this non-invasive technology in the evaluation of patients with voiding dysfunction The portable continuous wave NIRS instrument has a 3 laser diode light source (785, 808 and 830 nanometers), fiber optic cables for light transmission, a self adhesive patient interface patch with an emitter and sensor, and software to detect the difference between the light transmitted and received by the instrument. Software incorporated auto-attenuates the optical signals and converts raw optical data into chromophore concentrations displayed graphically. The prototype was designed, tested, and iteratively developed to achieve optimal suprapubic transcutaneous monitoring of the detrusor in human subjects during bladder filling and emptying. Evaluation with simultaneous invasive urodynamic measurement in men and women indicates good specificity and sensitivity of NIRS chromophore concentration changes by receiver operator curve analysis, and correlation between NIRS data and urodynamic pressures. Urological monitoring with this NIRS instrument is feasible and generates data of potential diagnostic value.

  5. Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klobe, L.E.

    1988-12-01

    The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNLmore » by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities.« less

  6. Mathematics Screening: The Development and Pilot Study of a Mathematics Screening Instrument for K-2 Grades

    ERIC Educational Resources Information Center

    Anderson, Stephen A.

    2010-01-01

    This paper summarizes an action research project to develop a math screening instrument that would be effective (valid and reliable) and efficient (time for administration). An instrument was developed after review of the mathematics assessment and mathematics disabilities literature. The instrument was administered to kindergarten, first, and…

  7. The development of an integrated assessment instrument for measuring analytical thinking and science process skills

    NASA Astrophysics Data System (ADS)

    Irwanto, Rohaeti, Eli; LFX, Endang Widjajanti; Suyanta

    2017-05-01

    This research aims to develop instrument and determine the characteristics of an integrated assessment instrument. This research uses 4-D model, which includes define, design, develop, and disseminate. The primary product is validated by expert judgment, tested it's readability by students, and assessed it's feasibility by chemistry teachers. This research involved 246 students of grade XI of four senior high schools in Yogyakarta, Indonesia. Data collection techniques include interview, questionnaire, and test. Data collection instruments include interview guideline, item validation sheet, users' response questionnaire, instrument readability questionnaire, and essay test. The results show that the integrated assessment instrument has Aiken validity value of 0.95. Item reliability was 0.99 and person reliability was 0.69. Teachers' response to the integrated assessment instrument is very good. Therefore, the integrated assessment instrument is feasible to be applied to measure the students' analytical thinking and science process skills.

  8. Developing and testing an instrument for identifying performance incentives in the Greek health care sector.

    PubMed

    Paleologou, Victoria; Kontodimopoulos, Nick; Stamouli, Aggeliki; Aletras, Vassilis; Niakas, Dimitris

    2006-09-13

    In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. A methodological exploratory design was employed in three phases: a) content development and assessment, which resulted in a 28-item instrument, b) pilot testing (N = 74) and c) field testing (N = 353). Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger sample of employees in the Greek healthcare system.

  9. Developing and testing an instrument for identifying performance incentives in the Greek health care sector

    PubMed Central

    Paleologou, Victoria; Kontodimopoulos, Nick; Stamouli, Aggeliki; Aletras, Vassilis; Niakas, Dimitris

    2006-01-01

    Background In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. Methods A methodological exploratory design was employed in three phases: a) content development and assessment, which resulted in a 28-item instrument, b) pilot testing (N = 74) and c) field testing (N = 353). Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Results Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Conclusion Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger sample of employees in

  10. Developing and testing instruments for improving cooperation and patient's participation in mental health care.

    PubMed

    Latvala, E; Saranto, K; Pekkala, E

    2004-10-01

    The main purpose of the project was to develop computerized instruments that could be used by nurses and patients to assess their cooperation and mutual contributions to care. This paper presents a part of the project: the reliability and validity testing phase of a process of instrument development. To test the validity and reliability of the instruments, data were collected with questionnaires from nurses (n = 146) and patients (n = 286). The validity evaluated as construct validity and the reliability evaluated as internal consistency of the instruments were quite good. Construct validity was tested by factor analysis, and internal consistency was tested by Cronbach's alpha coefficient, which varied from 0.69 to 0.79. The instruments, which consisted of a software application that can be operated in a www environment, were meant to be used as tools in the psychiatric nursing context for assessing the cooperation between the nurses and patients and the patient's participation in his/her care. Furthermore, the computer programme can be used as a tool for developing and assessing the patient orientation in nursing.

  11. Patient perspective workshop: moving towards OMERACT guidelines for choosing or developing instruments to measure patient-reported outcomes.

    PubMed

    Kirwan, John R; Fries, James F; Hewlett, Sarah E; Osborne, Richard H; Newman, Stanton; Ciciriello, Sabina; van de Laar, Mart A; Dures, Emma; Minnock, Patricia; Heiberg, Turid; Sanderson, Tessa C; Flurey, Caroline A; Leong, Amy L; Montie, Pamela; Richards, Pam

    2011-08-01

    The workshop Choosing or Developing Instruments held at the Outcome Measures in Rheumatology (OMERACT) 10 meeting was designed to help participants think about the underlying methods of instrument development. Conference pre-reading material and 3 brief introductory presentations elaborated the issues, and participants broke into discussion groups before reconvening to share insights, engage in a more general discussion of the issues, and vote on recommendations. Tradeoffs between using current imperfect measures and the long and complex process of developing new instruments were considered, together with the need for rigor in patient-reported outcome (PRO) instrument development. The main considerations for PRO instrument development were listed and a research agenda for action produced. As part of the agenda for action, it is recommended that researchers and patient partners work together to tackle these issues, and that OMERACT bring forward proposals for acceptable instrument development protocols that would meet an enhanced "Truth" statement in the OMERACT Filter.

  12. Attitudes to teaching mathematics: Further development of a measurement instrument

    NASA Astrophysics Data System (ADS)

    Relich, Joe; Way, Jenni; Martin, Andrew

    1994-07-01

    The evidence that a relationship exists between attitudes to teaching mathematics and the formation of positive attitudes to mathematics among pupils is somewhat tenuous. Nevertheless, there is a strong belief among pre-service teacher educators that positive attitudes need to be fostered in teacher education students, particularly for prospective primary school teachers. Unfortunately, the research evidence suggests that high proportions of pre-service teachers hold negative attitudes towards mathematics. Although many instruments measuring affect in areas such as self-concept, anxiety, etc. have appeared in the literature over the years, no comprehensive instrument on attitudes is available to help teacher educators monitor attitudinal changes among their pre-service student teachers to the teaching of mathematics. This research re-examines an earlier attempt to develop such an instrument in Australia (Nisbet, 1991) and posits an alternative and refined version.

  13. Mars Miniature Science Instruments

    NASA Technical Reports Server (NTRS)

    Kim, Soon Sam; Hayati, Samad; Lavery, David; McBrid, Karen

    2006-01-01

    For robotic Mars missions, all the science information is gathered through on-board miniature instruments that have been developed through many years of R&D. Compared to laboratory counterparts, the rover instruments require miniaturization, such as low mass (1-2 kg), low power (> 10 W) and compact (1-2 liter), yet with comparable sensitivity. Since early 1990's, NASA recognized the need for the miniature instruments and launched several instrument R&D programs, e.g., PIDDP (Planetary Instrument Definition and Development). However, until 1998, most of the instrument R&D programs supported only up to a breadboard level (TRL 3, 4) and there is a need to carry such instruments to flight qualifiable status (TU 5, 6) to respond to flight AOs (Announcement of Opportunity). Most of flight AOs have only limited time and financial resources, and can not afford such instrument development processes. To bridge the gap between instrument R&D programs and the flight instrument needs, NASA's Mars Technology Program (MTP) created advanced instrumentation program, Mars Instrument Development Project (MIDP). MIDP candidate instruments are selected through NASA Research Announcement (NRA) process [l]. For example, MIDP 161998-2000) selected and developed 10 instruments, MIDP II (2003-2005) 16 instruments, and MIDP III (2004-2006) II instruments.Working with PIs, JPL has been managing the MIDP tasks since September 1998. All the instruments being developed under MIDP have been selected through a highly competitive NRA process, and employ state-of-the-art technology. So far, four MIDP funded instruments have been selected by two Mars missions (these instruments have further been discussed in this paper).

  14. Development of an instrument to measure organisational culture in community pharmacies in Great Britain.

    PubMed

    Marques, Iuri; Willis, Sarah Caroline; Schafheutle, Ellen Ingrid; Hassell, Karen

    2018-04-09

    Purpose Organisational culture (OC) shapes individuals' perceptions and experiences of work. However, no instrument capable of measuring specific aspects of OC in community pharmacy exists. The purpose of this paper is to report the development and validation of an instrument to measure OC in community pharmacy in Great Britain (GB), and conduct a preliminary analysis of data collected using it. Design/methodology/approach Instrument development comprised three stages: Stage I: 12 qualitative interviews and relevant literature informed instrument design; Stage II: 30 cognitive interviews assessed content validity; and Stage III: a cross-sectional survey mailed to 1,000 community pharmacists in GB, with factor analysis for instrument validation. Statistical analysis investigated how community pharmacists perceived OC in their place of work. Findings Factor analysis produced an instrument containing 60 items across five OC dimensions - business and work configuration, social relationships, personal and professional development, skills utilisation, and environment and structures. Internal reliability for the dimensions was high (0.84 to 0.95); item-total correlations were adequate ( r=0.46 to r=0.76). Based on 209 responses, analysis suggests different OCs in community pharmacy, with some community pharmacists viewing the environment in which they worked as having a higher frequency of aspects related to patient contact and safety than others. Since these aspects are important for providing high healthcare standards, it is likely that differences in OC may be linked to different healthcare outcomes. Originality/value This newly developed and validated instrument to measure OC in community pharmacy can be used to benchmark existing OC across different pharmacies and design interventions for triggering change to improve outcomes for community pharmacists and patients.

  15. Inexpensive Instruments for a Sound Unit

    NASA Astrophysics Data System (ADS)

    Brazzle, Bob

    2011-04-01

    My unit on sound and waves is embedded within a long-term project in which my high school students construct a musical instrument out of common materials. The unit culminates with a performance assessment: students play the first four measures of "Somewhere Over the Rainbow"—chosen because of the octave interval of the first two notes—in the key of C, and write a short paper describing the theory underlying their instrument. My students have done this project for the past three years, and it continues to evolve. This year I added new instructional materials that I developed using a freeware program called Audacity. This software is very intuitive, and my students used it to develop their musical instruments. In this paper I will describe some of the inexpensive instructional materials in my sound unit, and how they fit with my learning goals.

  16. Bioecological Theory, Early Child Development and the Validation of the Population-Level Early Development Instrument

    ERIC Educational Resources Information Center

    Guhn, Martin; Goelman, Hillel

    2011-01-01

    The Early Development Instrument (EDI; Janus and Offord in "Canadian Journal of Behavioural Science" 39:1-22, 2007) project is a Canadian population-level, longitudinal research project, in which teacher ratings of Kindergarten children's early development and wellbeing are linked to health and academic achievement variables at the…

  17. Rasch Analysis for Instrument Development: Why, When, and How?

    ERIC Educational Resources Information Center

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to…

  18. Instrumental Music Educators' Experiences in a Professional Development Course

    ERIC Educational Resources Information Center

    Draves, Tami J.

    2017-01-01

    The purpose of this research was to investigate the experiences of instrumental music teachers in Designing Arts Instruction, a 4-day professional development course in a large urban school district. Specifically, I was interested in which activities participants (a) found most relevant and applicable to their current teaching situation, (b)…

  19. Psychometric Properties of Characteristics of Teacher Professional Development Instrument

    ERIC Educational Resources Information Center

    Soine, Karen M.

    2011-01-01

    This primary purpose of the study was to expand the work of Garet, Porter, Desimone, Birman, and Yoon (2001) by creating and psychometrically testing an instrument designed to measure teachers' perceptions of characteristics of professional development. Elementary teachers (n = 406) from five school districts in Washington State participating in a…

  20. Software structure for Vega/Chara instrument

    NASA Astrophysics Data System (ADS)

    Clausse, J.-M.

    2008-07-01

    VEGA (Visible spEctroGraph and polArimeter) is one of the focal instruments of the CHARA array at Mount Wilson near Los Angeles. Its control system is based on techniques developed on the GI2T interferometer (Grand Interferometre a 2 Telescopes) and on the SIRIUS fibered hyper telescope testbed at OCA (Observatoire de la Cote d'Azur). This article describes the software and electronics architecture of the instrument. It is based on local network architecture and uses also Virtual Private Network connections. The server part is based on Windows XP (VC++). The control software is on Linux (C, GTK). For the control of the science detector and the fringe tracking systems, distributed API use real-time techniques. The control software gathers all the necessary informations of the instrument. It allows an automatic management of the instrument by using an original task scheduler. This architecture intends to drive the instrument from remote sites, such as our institute in South of France.

  1. Focal plane instrument for the Solar UV-Vis-IR Telescope aboard SOLAR-C

    NASA Astrophysics Data System (ADS)

    Katsukawa, Yukio; Suematsu, Yoshinori; Shimizu, Toshifumi; Ichimoto, Kiyoshi; Takeyama, Norihide

    2011-10-01

    It is presented the conceptual design of a focal plane instrument for the Solar UV-Vis-IR Telescope (SUVIT) aboard the next Japanese solar mission SOLAR-C. A primary purpose of the telescope is to achieve precise as well as high resolution spectroscopic and polarimetric measurements of the solar chromosphere with a big aperture of 1.5 m, which is expected to make a significant progress in understanding basic MHD processes in the solar atmosphere. The focal plane instrument consists of two packages: A filtergraph package is to get not only monochromatic images but also Dopplergrams and magnetograms using a tunable narrow-band filter and interference filters. A spectrograph package is to perform accurate spectro-polarimetric observations for measuring chromospheric magnetic fields, and is employing a Littrow-type spectrograph. The most challenging aspect in the instrument design is wide wavelength coverage from 280 nm to 1.1 μm to observe multiple chromospheric lines, which is to be realized with a lens unit including fluoride glasses. A high-speed camera for correlation tracking of granular motion is also implemented in one of the packages for an image stabilization system, which is essential to achieve high spatial resolution and high polarimetric accuracy.

  2. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Wilcox, J. Z.; Urgiles, E.; Toda, R.; George, T.; Crisp, J.

    2005-01-01

    Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the

  3. Development of an instrument for assessing workstyle in checkout cashier work (BAsIK).

    PubMed

    Kjellberg, Katarina; Palm, Peter; Josephson, Malin

    2012-01-01

    Checkout cashier work consists of handling a large number of items during a work shift, which implies repetitive movements of the shoulders, arms and hands/wrists, and a high work rate. The work is associated with a high prevalence of disorders in the neck and upper extremity. The concept of workstyle explains how ergonomic and psychosocial factors interact in the development of work-related upper extremity disorders. The aim of the project was to develop an instrument for the occupational health services to be used in the efforts to prevent upper extremity disorders in checkout cashier work. The instrument is based on the workstyle concept and is intended to be used as a tool to identify high-risk workstyle and needs for interventions, such as training and education. The instrument, BAsIK, consists of four parts; a questionnaire about workstyle, an observation protocol for work technique, a checklist about the design of the checkout and a questionnaire about work organization. The instrument was developed by selecting workstyle items developed for office work and adapting them to checkout cashier work, discussions with researchers and ergonomists, focus-group interviews with cashiers, observations of video recordings of cashiers, and studies of existing guidelines and checklists.

  4. Scientific and technological Challenges in the development of astronomical instrumentation: E-ELT & ALMA

    NASA Astrophysics Data System (ADS)

    Barrado, David; Gallego, Jesús

    2009-12-01

    The answers to the present astrophysical questions require the development of highly sophisticated instrumentation, which needs long-term scheduling and large assets of human and material resources, managed by consortia of several institutions. Spain has carried in the last years serious efforts in this direction (GTC, ESO, ESA), but there is still a notable offset between astronomical research at the theoretical and observational levels and the development of instrumentation. Now, the incorporation of new countries to ESO (in particular Spain) to ESO and several future big projects (ALMA, E-ELT, Cosmic Vision), raise the level of exigency. The goal of this workshop is to gather the scientific teams and the industries of the sector to expose their needs and projects, and share experiences. The workshop is aimed as well at serving as an echo to convince financing agencies and the astronomical community in general of the need to promote with decision the development of astrophysical instrumentation and the tools for the analysis of related data. The formation and acknowledgement of instrumentation astronomers will be a key factor for Spain to meet the requirements of its position in Astronomy in the next decades. Here, we present the contributions most closely related to the development of E-ELT, ALMA and ESA missions.

  5. Develop real-time dosimetry concepts and instrumentation for long term missions

    NASA Technical Reports Server (NTRS)

    Braby, L. A.

    1982-01-01

    The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

  6. Psychometric Properties of the Chinese Family Assessment Instrument in Chinese Adolescents in Hong Kong

    ERIC Educational Resources Information Center

    Siu, Andrew M. H.; Shek, Daniel T. L.

    2005-01-01

    This paper reports evidence on the factor structure, reliability, and validity of the Chinese Family Assessment Instrument (C-FAI), an instrument developed to assess family functioning in Chinese populations. A convenience sample of 1,462 adolescents from junior secondary schools completed the C-FAI and measures of parent-adolescent conflict.…

  7. Survey Instrument Validity Part I: Principles of Survey Instrument Development and Validation in Athletic Training Education Research

    ERIC Educational Resources Information Center

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Context: Instrument validation is an important facet of survey research methods and athletic trainers must be aware of the important underlying principles. Objective: To discuss the process of survey development and validation, specifically the process of construct validation. Background: Athletic training researchers frequently employ the use of…

  8. Raman Life Detection Instrument Development for Icy Worlds

    NASA Technical Reports Server (NTRS)

    Thomson, Seamus; Allen, A'Lester; Gutierrez, Daniel; Quinn, Richard C.; Chen, Bin; Koehne, Jessica E.

    2017-01-01

    The objective of this project is to develop a compact, high sensitivity Raman sensor for detection of life signatures in a flow cell configuration to enable bio-exploration and life detection during future mission to our Solar Systems Icy Worlds. The specific project objectives are the following: 1) Develop a Raman spectroscopy liquid analysis sensor for biosignatures; 2) Demonstrate applicability towards a future Enceladus or other Icy Worlds missions; 3) Establish key parameters for integration with the ARC Sample Processor for Life on Icy Worlds (SPLIce); 4) Position ARC for a successful response to upcoming Enceladus or other Icy World mission instrument opportunities.

  9. An Assessment Instrument for Identifying Counseling Needs of Elementary-Aged Students: The Multimodal Sentence Completion Form for Children (MSCF-C).

    ERIC Educational Resources Information Center

    Gamble, Charles W.; Hamblin, Arthur G.

    1986-01-01

    Discusses the use of a sentence completion instrument predicated on Lazarus' multimodal system. The instrument, entitled The Multimodal Sentence Completion Form for Children (MSCF-C), is designed to systematically assess client needs and assist in identifying intervention strategies. Presents a case study of a 12-year-old, sixth-grade student.…

  10. Development of Low-Cost Instrumentation for Single Point Autofluorescence Lifetime Measurements.

    PubMed

    Lagarto, João; Hares, Jonathan D; Dunsby, Christopher; French, Paul M W

    2017-09-01

    Autofluorescence lifetime measurements, which can provide label-free readouts in biological tissues, contrasting e.g. different types and states of tissue matrix components and different cellular metabolites, may have significant clinical potential for diagnosis and to provide surgical guidance. However, the cost of the instrumentation typically used currently presents a barrier to wider implementation. We describe a low-cost single point time-resolved autofluorescence instrument, exploiting modulated laser diodes for excitation and FPGA-based circuitry for detection, together with a custom constant fraction discriminator. Its temporal accuracy is compared against a "gold-standard" instrument incorporating commercial TCSPC circuitry by resolving the fluorescence decays of reference fluorophores presenting single and double exponential decay profiles. To illustrate the potential to read out intrinsic contrast in tissue, we present preliminary measurements of autofluorescence lifetime measurements of biological tissues ex vivo. We believe that the lower cost of this instrument could enhance the potential of autofluorescence lifetime metrology for clinical deployment and commercial development.

  11. New developments in the McStas neutron instrument simulation package

    NASA Astrophysics Data System (ADS)

    Willendrup, P. K.; Knudsen, E. B.; Klinkby, E.; Nielsen, T.; Farhi, E.; Filges, U.; Lefmann, K.

    2014-07-01

    The McStas neutron ray-tracing software package is a versatile tool for building accurate simulators of neutron scattering instruments at reactors, short- and long-pulsed spallation sources such as the European Spallation Source. McStas is extensively used for design and optimization of instruments, virtual experiments, data analysis and user training. McStas was founded as a scientific, open-source collaborative code in 1997. This contribution presents the project at its current state and gives an overview of the main new developments in McStas 2.0 (December 2012) and McStas 2.1 (expected fall 2013), including many new components, component parameter uniformisation, partial loss of backward compatibility, updated source brilliance descriptions, developments toward new tools and user interfaces, web interfaces and a new method for estimating beam losses and background from neutron optics.

  12. Developing and validating an instrument for measuring mobile computing self-efficacy.

    PubMed

    Wang, Yi-Shun; Wang, Hsiu-Yuan

    2008-08-01

    IT-related self-efficacy has been found to have a critical influence on system use. However, traditional measures of computer self-efficacy and Internet-related self-efficacy are perceived to be inapplicable in the context of mobile computing and commerce because they are targeted primarily at either desktop computer or wire-based technology contexts. Based on previous research, this study develops and validates a multidimensional instrument for measuring mobile computing self-efficacy (MCSE). This empirically validated instrument will be useful to researchers in developing and testing the theories of mobile user behavior, and to practitioners in assessing the mobile computing self-efficacy of users and promoting the use of mobile commerce systems.

  13. Development of an inter-professional screening instrument for cancer patients' education process.

    PubMed

    Vaartio-Rajalin, Heli; Huumonen, Tuula; Iire, Liisa; Jekunen, Antti; Leino-Kilpi, Helena; Minn, Heikki; Paloniemi, Jenni; Zabalegui, Adelaida

    2016-02-01

    The aim of this paper is to describe the development of an inter-professional screening instrument for cancer patients' cognitive resources, knowledge expectations and inter-professional collaboration within patient education. Four empirical datasets during 2012-2014 were analyzed in order to identify main categories, subcategories and items for inter-professional screening instrument. Our inter-professional screening instrument integrates the critical moments of cancer patient education and the knowledge expectation types obtained from patient datasets to assessment of patients' cognitive resources, knowledge expectations and comprehension; and intra; and inter-professional. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Development of a Coding Instrument to Assess the Quality and Content of Anti-Tobacco Video Games.

    PubMed

    Alber, Julia M; Watson, Anna M; Barnett, Tracey E; Mercado, Rebeccah; Bernhardt, Jay M

    2015-07-01

    Previous research has shown the use of electronic video games as an effective method for increasing content knowledge about the risks of drugs and alcohol use for adolescents. Although best practice suggests that theory, health communication strategies, and game appeal are important characteristics for developing games, no instruments are currently available to examine the quality and content of tobacco prevention and cessation electronic games. This study presents the systematic development of a coding instrument to measure the quality, use of theory, and health communication strategies of tobacco cessation and prevention electronic games. Using previous research and expert review, a content analysis coding instrument measuring 67 characteristics was developed with three overarching categories: type and quality of games, theory and approach, and type and format of messages. Two trained coders applied the instrument to 88 games on four platforms (personal computer, Nintendo DS, iPhone, and Android phone) to field test the instrument. Cohen's kappa for each item ranged from 0.66 to 1.00, with an average kappa value of 0.97. Future research can adapt this coding instrument to games addressing other health issues. In addition, the instrument questions can serve as a useful guide for evidence-based game development.

  15. Development of a Coding Instrument to Assess the Quality and Content of Anti-Tobacco Video Games

    PubMed Central

    Alber, Julia M.; Watson, Anna M.; Barnett, Tracey E.; Mercado, Rebeccah

    2015-01-01

    Abstract Previous research has shown the use of electronic video games as an effective method for increasing content knowledge about the risks of drugs and alcohol use for adolescents. Although best practice suggests that theory, health communication strategies, and game appeal are important characteristics for developing games, no instruments are currently available to examine the quality and content of tobacco prevention and cessation electronic games. This study presents the systematic development of a coding instrument to measure the quality, use of theory, and health communication strategies of tobacco cessation and prevention electronic games. Using previous research and expert review, a content analysis coding instrument measuring 67 characteristics was developed with three overarching categories: type and quality of games, theory and approach, and type and format of messages. Two trained coders applied the instrument to 88 games on four platforms (personal computer, Nintendo DS, iPhone, and Android phone) to field test the instrument. Cohen's kappa for each item ranged from 0.66 to 1.00, with an average kappa value of 0.97. Future research can adapt this coding instrument to games addressing other health issues. In addition, the instrument questions can serve as a useful guide for evidence-based game development. PMID:26167842

  16. Development of a Portable, Ground-Based Ozone Lidar Instrument for Tropospheric Ozone Research and Educational Training

    NASA Technical Reports Server (NTRS)

    Chyba, Thomas; Zenker, Thomas

    1998-01-01

    The objective of this project is to develop a portable, eye-safe, ground-based ozone lidar instrument specialized for ozone differential absorption lidar (DIAL) measurements in the troposphere. This prototype instrument is intended to operate at remote field sites and to serve as the basic unit for monitoring projects requiring multi-instrument networks, such as that discussed in the science plan for the Global Tropospheric Ozone Project (GTOP). This instrument will be based at HU for student training in lidar technology as well as atmospheric ozone data analysis and interpretation. It will be also available for off-site measurement campaigns and will serve as a test bed for further instrument development. Later development beyond this grant to extend the scientific usefulness of the instrument may include incorporation of an aerosol channel and upgrading the laser to make stratospheric ozone measurements. Undergraduate and graduate students have been and will be active participants in this research effort.

  17. Development of collaborative-creative learning model using virtual laboratory media for instrumental analytical chemistry lectures

    NASA Astrophysics Data System (ADS)

    Zurweni, Wibawa, Basuki; Erwin, Tuti Nurian

    2017-08-01

    The framework for teaching and learning in the 21st century was prepared with 4Cs criteria. Learning providing opportunity for the development of students' optimal creative skills is by implementing collaborative learning. Learners are challenged to be able to compete, work independently to bring either individual or group excellence and master the learning material. Virtual laboratory is used for the media of Instrumental Analytical Chemistry (Vis, UV-Vis-AAS etc) lectures through simulations computer application and used as a substitution for the laboratory if the equipment and instruments are not available. This research aims to design and develop collaborative-creative learning model using virtual laboratory media for Instrumental Analytical Chemistry lectures, to know the effectiveness of this design model adapting the Dick & Carey's model and Hannafin & Peck's model. The development steps of this model are: needs analyze, design collaborative-creative learning, virtual laboratory media using macromedia flash, formative evaluation and test of learning model effectiveness. While, the development stages of collaborative-creative learning model are: apperception, exploration, collaboration, creation, evaluation, feedback. Development of collaborative-creative learning model using virtual laboratory media can be used to improve the quality learning in the classroom, overcome the limitation of lab instruments for the real instrumental analysis. Formative test results show that the Collaborative-Creative Learning Model developed meets the requirements. The effectiveness test of students' pretest and posttest proves significant at 95% confidence level, t-test higher than t-table. It can be concluded that this learning model is effective to use for Instrumental Analytical Chemistry lectures.

  18. Harsh Environment Silicon Carbide Sensor Technology for Geothermal Instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pisano, Albert P.

    2013-04-26

    This project utilizes Silicon Carbide (SiC) materials platform to fabricate advanced sensors to be used as high-temperature downhole instrumentation for the DOE’s Geothermal Technologies Program on Enhanced Geothermal Systems. The scope of the proposed research is to 1) develop a SiC pressure sensor that can operate in harsh supercritical conditions, 2) develop a SiC temperature sensor that can operate in harsh supercritical conditions, 3) develop a bonding process for adhering SiC sensor die to well casing couplers, and 4) perform experimental exposure testing of sensor materials and the sensor devices.

  19. The SUVIT Instrument on the Solar-C Mission

    NASA Astrophysics Data System (ADS)

    Tarbell, Theodore D.; Ichimoto, Kiyoshi

    2014-06-01

    Solar-C is a new space mission being proposed to JAXA, with significant contributions anticipated from NASA, ESA, and EU countries. The main scientific objectives are to: reveal the mechanisms for heating and dynamics of the chromosphere and corona and acceleration of the solar wind; determine the physical origin of the large-scale explosions and eruptions that drive short-term solar, heliospheric, and geospace variability; use the solar atmosphere as a laboratory for understanding fundamental physical processes; make unprecedented observations of the polar magnetic fields. The unique approaches of Solar-C to achieve these goals are to: determine the properties and evolution of the 3-dimensional magnetic field, especially on small spatial scales, and for the first time observed in the crucial low beta plasma region; observe all the temperature regimes of the atmosphere seamlessly at the highest spatial resolution ever achieved; observe at high cadence the prevailing dynamics in all regions of the atmosphere; determine physical properties from high resolution spectroscopic measurements throughout the atmosphere and into the solar wind. The powerful suite of instruments onboard Solar-C will be sensitive to temperatures from the photosphere 5500 K) to solar flares 20 MK) with no temperature gap, with spatial resolution at all temperatures of 0.3″ or less (0.1″ in the lower atmosphere) and at high cadence. The purpose of the Solar UV-Visible-IR Telescope (SUVIT) is to obtain chromospheric velocity, temperature, density and magnetic field diagnostics over as wide arange of heights as possible, through high cadence spectral line profiles and vector spectro-polarimetry. SUVIT is a meter-class telescope currently under study at 1.4m in order to obtain sufficientresolution and S/N. SUVIT has two complementary focal plane packages, the Filtergraph that makes high cadence imaging observations with the highest spatial resolution and the Spectro-polarimeter that makes

  20. 32 CFR 37.105 - Does this part cover all types of instruments that 10 U.S.C. 2371 authorizes?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... covers only TIAs, some of which use the authority of 10 U.S.C. 2371 (see appendix B to this part). This part does not cover assistance instruments other than TIAs that use the authority of 10 U.S.C. 2371. It also does not cover acquisition agreements for prototype projects that use 10 U.S.C. 2371 authority...

  1. Verbal and Nonverbal Classroom Communication: The Development of an Observational Instrument.

    ERIC Educational Resources Information Center

    Heger, Herbert K.

    This paper reports the development of a classroom observation instrument designed to broaden and extend the power of existing tools to provide a balanced, reciprocal perspective of both verbal and nonverbal communication. An introductory section discusses developments in communication analysis. The Miniaturized Total Interaction Analysis System…

  2. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    PubMed

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  3. Development of an Instrument to Measure Higher Order Thinking Skills in Senior High School Mathematics Instruction

    ERIC Educational Resources Information Center

    Tanujaya, Benidiktus

    2016-01-01

    The purpose of this research was to develop an instrument that can be used to measure higher-order thinking skills (HOTS) in mathematics instruction of high school students. This research was conducted using a standard procedure of instrument development, from the development of conceptual definitions, development of operational definitions,…

  4. [Development of an Instrument to Assess the Quality of Childbirth Care from the Mother's Perspective].

    PubMed

    Jeong, Geum Hee; Kim, Hyun Kyoung; Kim, Young Hee; Kim, Sun Hee; Lee, Sun Hee; Kim, Kyung Won

    2018-02-01

    This study aimed to develop an instrument to assess the quality of childbirth care from the perspective of a mother after delivery. The instrument was developed from a literature review, interviews, and item validation. Thirty-eight items were compiled for the instrument. The data for validity and reliability testing were collected using a questionnaire survey conducted on 270 women who had undergone normal vaginal delivery in Korea and analyzed with descriptive statistics, exploratory factor analysis, and reliability coefficients. The exploratory factor analysis reduced the number of items in the instrument to 28 items that were factored into four subscales: family-centered care, personal care, emotional empowerment, and information provision. With respect to convergence validation, there was positive correlation between this instrument and birth satisfaction scale (r=.34, p<.001). The internal consistency reliability was acceptable (Cronbach's alpha =.96). This instrument could be used as a measure of the quality of nursing care for women who have a normal vaginal delivery. © 2018 Korean Society of Nursing Science.

  5. Development and psychometric evaluation of workplace psychologically violent behaviours instrument.

    PubMed

    Dilek, Yildirim; Aytolan, Yildirim

    2008-05-01

    To develop an instrument to determine nurses' perceptions of psychologically violent behaviours that they are exposed to in the workplace. According to Leymann, psychological terror or mobbing in work life involves hostile and unethical communication, which is directed in a systematic way towards one individual who, due to mobbing, is pushed into a helpless and defenceless position, and being held there by means of continuing mobbing activities. Survey. Because nurses who work in hospitals are generally the principle victims of physical, emotional and verbal violence due to the nature of their work environment, the research sample comprised 476 hospital nurses. Data were collected via self-administered questionnaires. The instrument to determine the perception of workplace psychologically violent behaviours contains 33 items and four factors (individual's isolation from work, attack on professional status, attack on personality and direct attack). All items have shown statistically significant correlation (p < 0.01); the instrument's total Cronbach's alpha internal consistency coefficient was found to be 0.93. The findings show that the instrument's validity and reliability are within the limits of an acceptable level and that it is an instrument that will encourage more studies on this subject. Defining the psychological pressure that nurses are exposed to in the workplace and determining its negative effects on the victim of workplace psychological pressure and on the institution will make it possible to protect individuals and the institution from psychological violence with both individual and institutional practices.

  6. Development and psychometric testing of an instrument to measure safety climate perceptions in community pharmacy.

    PubMed

    Newham, Rosemary; Bennie, Marion; Maxwell, David; Watson, Anne; de Wet, Carl; Bowie, Paul

    2014-12-01

    A positive and strong safety culture underpins effective learning from patient safety incidents in health care, including the community pharmacy (CP) setting. To build this culture, perceptions of safety climate must be measured with context-specific and reliable instruments. No pre-existing instruments were specifically designed or suitable for CP within Scotland. We therefore aimed to develop a psychometrically sound instrument to measure perceptions of safety climate within Scottish CPs. The first stage, development of a preliminary instrument, comprised three steps: (i) a literature review; (ii) focus group feedback; and (iii) content validation. The second stage, psychometric testing, consisted of three further steps: (iv) a pilot survey; (v) a survey of all CP staff within a single health board in NHS Scotland; and (vi) application of statistical methods, including principal components analysis and calculation of Cronbach's reliability coefficients, to derive the final instrument. The preliminary questionnaire was developed through a process of literature review and feedback. This questionnaire was completed by staff in 50 CPs from the 131 (38%) sampled. 250 completed questionnaires were suitable for analysis. Psychometric evaluation resulted in a 30-item instrument with five positively correlated safety climate factors: leadership, teamwork, safety systems, communication and working conditions. Reliability coefficients were satisfactory for the safety climate factors (α > 0.7) and overall (α = 0.93). The robust nature of the technical design and testing process has resulted in the development of an instrument with sufficient psychometric properties, which can be implemented in the community pharmacy setting in NHS Scotland. © 2014 John Wiley & Sons, Ltd.

  7. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    NASA Astrophysics Data System (ADS)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  8. An integrative research review of instruments measuring religious involvement: implications for nursing research with African Americans.

    PubMed

    Mokel, Melissa Jennifer; Shellman, Juliette M

    2013-01-01

    Many instruments in which religious involvement is measured often (a) contain unclear, poorly developed constructs; (b) lack methodological rigor in scale development; and (c) contain language and content culturally incongruent with the religious experiences of diverse ethnic groups. The primary aims of this review were to (a) synthesize the research on instruments designed to measure religious involvement, (b) evaluate the methodological quality of instruments that measure religious involvement, and (c) examine these instruments for conceptual congruency with African American religious involvement. An updated integrative research review method guided the process (Whittemore & Knafl, 2005). 152 articles were reviewed and 23 articles retrieved. Only 3 retained instruments were developed under methodologically rigorous conditions. All 3 instruments were congruent with a conceptual model of African American religious involvement. The Fetzer Multidimensional Measure of Religious Involvement and Spirituality (FMMRS; Idler et al., 2003) was found to have favorable characteristics. Further examination and psychometric testing is warranted to determine its acceptability, readability, and cultural sensitivity in an African American population.

  9. Development and Validation of the Blended Learning Environment Instrument (BLEI) in Higher Education

    ERIC Educational Resources Information Center

    Aljahni, Areej; Al-Begain, Khalid; Skinner, Heather

    2014-01-01

    Part of ongoing research into the efficacy of blended learning in higher education within the Kingdom of Saudi Arabia (KSA). The need for, and development of, a Blended Learning Environment Instrument (BLEI) are explained. This new instrument assesses student perceptions across five core aspects of blended learning environments: Infrastructure,…

  10. But Does It Work? Reflective Activities, Learning Outcomes and Instrumental Learning in Continuing Professional Development

    ERIC Educational Resources Information Center

    Roessger, Kevin M.

    2015-01-01

    This paper examines the relationship between reflective practice and instrumental learning within the context of continuing professional development (CPD). It is argued that instrumental learning is a unique process of adult learning, and reflective practice's impact on learning outcomes in instrumental learning contexts remains unclear. A…

  11. Organizational member involvement in physical activity coalitions across the United States: development and testing of a novel survey instrument for assessing coalition functioning.

    PubMed

    Bornstein, Daniel B; Pate, Russell R; Beets, Michael W; Saunders, Ruth P; Blair, Steven N

    2015-06-01

    Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement in physical activity coalitions. The study was carried out in three phases: (a) developing a draft survey, (b) assessing the content validity of the draft survey, and (c) assessing the underlying factor structure, reliability, and validity of the survey. A cross-sectional design was employed. In Phase 1, a team of experts in survey development produced a draft survey. In Phase 2, the content validity of the draft survey was evaluated by a panel of individuals with expertise in physical activity coalitions. In Phase 3, the survey was administered to 120 individuals on local-, state-, and national-level physical activity coalitions. Responses were subjected to an exploratory factor analysis in order to determine the survey's underlying factor structure, reliability, and validity. Phases 1 and 2yielded a survey instrument with demonstrated content validity. Phase 3 yielded a three-factor model with three subscales: Strategic Alignment, Organizational Alignment, and Providing Input. Each subscale demonstrated high internal consistency reliability and construct validity. The survey instrument developed here demonstrated sound psychometric properties and provides new insight into organizational member involvement in physical activity coalitions. This instrument may be an important tool in developing a more complete picture of coalition functioning in physical activity coalitions specifically and health-based coalitions overall. © 2014 Society for Public Health Education.

  12. Development and Score Validation of a Chemistry Laboratory Anxiety Instrument (CLAI) for College Chemistry Students.

    ERIC Educational Resources Information Center

    Bowen, Craig W.

    1999-01-01

    Reports the development and score validation of an instrument for measuring anxieties students experience in college chemistry laboratories. Factor analysis of scores from 361 college students shows that the developed Chemistry Laboratory Anxiety Instrument measures five constructs. Results from a second sample of 598 students show that scores on…

  13. Identifying instruments to quantify financial management skills in adults with acquired cognitive impairments.

    PubMed

    Engel, Lisa; Bar, Yael; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2016-01-01

    Financial management skills-that is, the skills needed to handle personal finances such as banking and paying bills-are essential to a person's autonomy, independence, and community living. To date, no comprehensive review of financial management skills instruments exists, making it difficult for clinicians and researchers to choose relevant instruments. The objectives of this review are to: (a) identify all available instruments containing financial management skill items that have been used with adults with acquired cognitive impairments; (b) categorize the instruments by source (i.e., observation based, self-report, proxy report); and (c) describe observation-based performance instruments by populations, overarching concepts measured, and comprehensiveness of financial management items. Objective (c) focuses on observation-based performance instruments as these measures can aid in situations where the person with cognitive impairment has poor self-awareness or where the proxy has poor knowledge of the person's current abilities. Two reviewers completed two systematic searches of five databases. Instruments were categorized by reviewing published literature, copies of the instruments, and/or communication with instrument authors. Comprehensiveness of items was based on nine key domains of financial management skills developed by the authors. A total of 88 discrete instruments were identified. Of these, 44 were categorized as observation-based performance and 44 as self- and/or proxy-reports. Of the 44 observation-based performance instruments, 8 had been developed for acquired brain injury populations and 24 for aging and dementia populations. Only 7 of the observation-based performance instruments had items spanning 6 or more of the 9 financial management skills domains. The majority of instruments were developed for aging and dementia populations, and few were comprehensive. This review provides foundation for future instrument psychometric and clinimetric

  14. Neutral atoms facility for space sensors characterization and BepiColombo/ELENA development instrument's progresses.

    NASA Astrophysics Data System (ADS)

    de Angelis, E.; di Lellis, A. M.; Orsini, S.; Zanza, V.; Maggi, M.; Vertolli, N.; D'Amicis, R.; Tilia, B.; Sibio, A.

    2003-04-01

    An Energetic Neutral Atoms facility to test and calibrate Neutral Atoms Analyzers has been developed in the Scientific Technical Unit of Fusion at the ENEA Research Center in Frascati (Rome-Italy). In the last years a collaboration with IFSI (Interplanetary Space and Physics Institute, CNR-Rome-Italy) has allowed to use this facility for space sensors and for characterization of crucial instruments elements. The ENA beam is realized with an ion source and a neutralization cell, and allows to test any instrument in the energy range 300eV-110keV with the available masses of Hydrogen, Deuterium or Helium. At the moment, the critical elements of ELENA (Emitted Low Energy Neutral Atoms) instrument proposed for BepiColombo ESA cornerstone mission to Mercury is under development testing. The facility, its potentiality and the instrument characterization progresses are presented.

  15. Long-Term Instrumentation, Information, and Control Systems (II&C) Modernization Future Vision and Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenneth Thomas

    2012-02-01

    Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970's vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performancemore » improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades. A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. DOE's program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy security and environmental security . The Advanced II&C research pathway is being conducted by the Idaho National Laboratory (INL). The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a

  16. Long-Term Instrumentation, Information, and Control Systems (II&C) Modernization Future Vision and Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kenneth Thomas; Bruce Hallbert

    2013-02-01

    Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970’s vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performancemore » improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades. A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. DOE’s program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy security and environmental security . The Advanced II&C research pathway is being conducted by the Idaho National Laboratory (INL). The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a

  17. Instrumentation for optical ocean remote sensing

    NASA Technical Reports Server (NTRS)

    Esaias, W. E.

    1991-01-01

    Instruments used in ocean color remote sensing algorithm development, validation, and data acquisition which have the potential for further commercial development and marketing are discussed. The Ocean Data Acquisition System (ODAS) is an aircraft-borne radiometer system suitable for light aircraft, which has applications for rapid measurement of chlorophyll pigment concentrations along the flight line. The instrument package includes a three channel radiometer system for upwelling radiance, an infrared temperature sensor, a three-channel downwelling irradiance sensor, and Loran-C navigation. Data are stored on a PC and processed to transects or interpolated 'images' on the ground. The instrument has been in operational use for two and one half years. The accuracy of pigment concentrations from the instrument is quite good, even in complex Chesapeake Bay waters. To help meet the requirement for validation of future satellite missions, a prototype air-deployable drifting buoy for measurement of near-surface upwelled radiance in multiple channnels is undergoing test deployment. The optical drifter burst samples radiance, stores and processes the data, and uses the Argos system as a data link. Studies are underway to explore the limits to useful lifetime with respect to power and fouling.

  18. Development of the evaluation instrument use CIPP on the implementation of project assessment topic optik

    NASA Astrophysics Data System (ADS)

    Asfaroh, Jati Aurum; Rosana, Dadan; Supahar

    2017-08-01

    This research aims to develop an evaluation instrument models CIPP valid and reliable as well as determine the feasibility and practicality of an evaluation instrument models CIPP. An evaluation instrument models CIPP to evaluate the implementation of the project assessment topic optik to measure problem-solving skills of junior high school class VIII in the Yogyakarta region. This research is a model of development that uses 4-D. Subject of product trials are students in class VIII SMP N 1 Galur and SMP N 1 Sleman. Data collection techniques in this research using non-test techniques include interviews, questionnaires and observations. Validity in this research was analyzed using V'Aikens. Reliability analyzed using ICC. This research uses 7 raters are derived from two lecturers expert (expert judgment), two practitioners (science teacher) and three colleagues. The results of this research is the evaluation's instrument model of CIPP is used to evaluate the implementation of the implementation of the project assessment instruments. The validity result of evaluation instrument have V'Aikens values between 0.86 to 1, which means a valid and 0.836 reliability values into categories so well that it has been worth used as an evaluation instrument.

  19. Development and Validation of Scores from an Instrument Measuring Student Test-Taking Motivation

    ERIC Educational Resources Information Center

    Eklof, Hanna

    2006-01-01

    Using the expectancy-value model of achievement motivation as a basis, this study's purpose is to develop, apply, and validate scores from a self-report instrument measuring student test-taking motivation. Sampled evidence of construct validity for the present sample indicates that a number of the items in the instrument could be used as an…

  20. Planetary instrument definition and development program: 'Miniature Monochromatic Imager'

    NASA Technical Reports Server (NTRS)

    Broadfoot, A. L.

    1991-01-01

    The miniature monochromatic imager (MMI) development work became the basis for the preparation of several instruments which were built and flown on the shuttle STS-39 as well as being used in ground based experiments. The following subject areas are covered: (1) applications of the ICCD to airglow and auroral measurements and (2) a panchromatic spectrograph with supporting monochromatic imagers.

  1. NASA Instrument Cost/Schedule Model

    NASA Technical Reports Server (NTRS)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  2. Development of an Instrument to Measure Student Use of Academic Success Skills: An Exploratory Factor Analysis

    ERIC Educational Resources Information Center

    Carey, John; Brigman, Greg; Webb, Linda; Villares, Elizabeth; Harrington, Karen

    2014-01-01

    This article describes the development of the Student Engagement in School Success Skills instrument including item development and exploratory factor analysis. The instrument was developed to measure student use of the skills and strategies identified as most critical for long-term school success that are typically taught by school counselors.

  3. Development and validation of an instrument to assess job satisfaction in eye-care personnel.

    PubMed

    Paudel, Prakash; Cronjé, Sonja; O'Connor, Patricia M; Khadka, Jyoti; Rao, Gullapalli N; Holden, Brien A

    2017-11-01

    The aim was to develop and validate an instrument to measure job satisfaction in eye-care personnel and assess the job satisfaction of one-year trained vision technicians in India. A pilot instrument for assessing job satisfaction was developed, based on a literature review and input from a public health expert panel. Rasch analysis was used to assess psychometric properties and to undertake an iterative item reduction. The instrument was then administered to vision technicians in vision centres of Andhra Pradesh in India. Associations between vision technicians' job satisfaction and factors such as age, gender and experience were analysed using t-test and one-way analysis of variance. Rasch analysis confirmed that the 15-item job satisfaction in eye-care personnel (JSEP) was a unidimensional instrument with good fit statistics, measurement precisions and absence of differential item functioning. Overall, vision technicians reported high rates of job satisfaction (0.46 logits). Age, gender and experience were not associated with high job satisfaction score. Item score analysis showed non-financial incentives, salary and workload were the most important determinants of job satisfaction. The 15-item JSEP instrument is a valid instrument for assessing job satisfaction among eye-care personnel. Overall, vision technicians in India demonstrated high rates of job satisfaction. © 2016 Optometry Australia.

  4. The Eastland Prostate Cancer Survey: instrument development and psychometric testing.

    PubMed

    Eastland, Taryn Y; Dancy, Barbara L

    2013-03-01

    African-American (AA) women could be instrumental in communicating positive prostate screening behavior to the significant males in their lives. However, little is known about AA women's prostate cancer attitudes, perceived behavioral control, subjective norms, intentions, behaviors, and knowledge regarding prostate cancer screening. This study describes the development and psychometric testing of the Eastland Prostate Cancer Survey (EPCS). A nonexperimental, correlational study with 200 AA women was used to test the psychometric properties of the six-subscale EPCS with 66 items. Construct validity, internal consistency, and test-retest reliability for the EPCS were acceptable and resulted in an eight-subscale EPCS with 56 items. Cronbach's alphas for the subscales ranged from 0.69 to 0.92. The EPCS is a culturally sensitive, gender-relevant instrument that could be used by community health providers to develop community health programs aimed at engaging AA women in the promotion of prostate cancer screening for AA men.

  5. Orthodontic instrument sterilization with microwave irradiation.

    PubMed

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-04-01

    This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups - Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min.

  6. Communication preferences of chronically ill adolescents: development of an assessment instrument.

    PubMed

    Klosinski, Matthias G; Farin, Erik

    2015-09-01

    The purpose of this study was to develop and psychometrically test a patient-oriented, theory-based questionnaire to capture the communication preferences of chronically ill adolescents in provider-patient interaction. In a qualitative prestudy, patients were asked to express their preferences in focus groups. From those results and relying on previous research findings, we generated questionnaire items and in a second pretest, examined them in 1-to-1 cognitive interviews for comprehensibility and acceptance. The resultant questionnaire was then psychometrically tested in the main study on 423 chronically ill inpatient adolescents aged 12 to 17 years in 14 rehabilitation clinics in Germany. Numerous preferences were extractable from the focus-group interviews and transferred into 106 Items. Psychometric testing of the questionnaire resulted in 3 scales encompassing 27 items. These we describe as the emotional-affective communication component (EAC), instrumental communication component (IC), and adolescent-specific communication component (ASC). Confirmatory factor analysis revealed the scales EAC und IC to be good to very good, and the ASC scale as satisfactory regarding unidimensionality. The participants gave the questionnaire high marks for comprehensibility, acceptance, and relevance. The 3 scales' Cronbach's alpha falls between .78 and .92. A questionnaire with 27 items is now available for application as a psychometrically tested and simple-to-use measuring instrument. Research is still needed concerning the generalizability to other patient groups (e.g., the acutely ill or outpatients) and whether it can be tailored for use by different types of care providers or to accommodate the communication preferences of parents. (c) 2015 APA, all rights reserved.

  7. Development and evaluation of an instrument for assessing brief behavioral change interventions.

    PubMed

    Strayer, Scott M; Martindale, James R; Pelletier, Sandra L; Rais, Salehin; Powell, Jon; Schorling, John B

    2011-04-01

    To develop an observational coding instrument for evaluating the fidelity and quality of brief behavioral change interventions based on the behavioral theories of the 5 A's, Stages of Change and Motivational Interviewing. Content and face validity were assessed prior to an intervention where psychometric properties were evaluated with a prospective cohort of 116 medical students. Properties assessed included the inter-rater reliability of the instrument, internal consistency of the full scale and sub-scales and descriptive statistics of the instrument. Construct validity was assessed based on student's scores. Inter-rater reliability for the instrument was 0.82 (intraclass correlation). Internal consistency for the full scale was 0.70 (KR20). Internal consistencies for the sub-scales were as follows: MI intervention component (KR20=.7); stage-appropriate MI-based intervention (KR20=.55); MI spirit (KR20=.5); appropriate assessment (KR20=.45) and appropriate assisting (KR20=.56). The instrument demonstrated good inter-rater reliability and moderate overall internal consistency when used to assess performing brief behavioral change interventions by medical students. This practical instrument can be used with minimal training and demonstrates promising psychometric properties when evaluated with medical students counseling standardized patients. Further testing is required to evaluate its usefulness in clinical settings. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. The Pediatrics Milestones Assessment Pilot: Development of Workplace-Based Assessment Content, Instruments, and Processes.

    PubMed

    Hicks, Patricia J; Margolis, Melissa; Poynter, Sue E; Chaffinch, Christa; Tenney-Soeiro, Rebecca; Turner, Teri L; Waggoner-Fountain, Linda; Lockridge, Robin; Clyman, Stephen G; Schwartz, Alan

    2016-05-01

    To report on the development of content and user feedback regarding the assessment process and utility of the workplace-based assessment instruments of the Pediatrics Milestones Assessment Pilot (PMAP). One multisource feedback instrument and two structured clinical observation instruments were developed and refined by experts in pediatrics and assessment to provide evidence for nine competencies based on the Pediatrics Milestones (PMs) and chosen to inform residency program faculty decisions about learners' readiness to serve as pediatric interns in the inpatient setting. During the 2012-2013 PMAP study, 18 U.S. pediatric residency programs enrolled interns and subinterns. Faculty, residents, nurses, and other observers used the instruments to assess learner performance through direct observation during a one-month rotation. At the end of the rotation, data were aggregated for each learner, milestone levels were assigned using a milestone classification form, and feedback was provided to learners. Learners and site leads were surveyed and/or interviewed about their experience as participants. Across the sites, 2,338 instruments assessing 239 learners were completed by 630 unique observers. Regarding end-of-rotation feedback, 93% of learners (128/137) agreed the assessments and feedback "helped me understand how those with whom I work perceive my performance," and 85% (117/137) agreed they were "useful for constructing future goals or identifying a developmental path." Site leads identified several benefits and challenges to the assessment process. PM-based instruments used in workplace-based assessment provide a meaningful and acceptable approach to collecting evidence of learner competency development. Learners valued feedback provided by PM-based assessment.

  9. Development of an instrument to measure self-efficacy in caregivers of people with advanced cancer.

    PubMed

    Ugalde, Anna; Krishnasamy, Meinir; Schofield, Penelope

    2013-06-01

    Informal caregivers of people with advanced cancer experience many negative impacts as a result of their role. There is a lack of suitable measures specifically designed to assess their experience. This study aimed to develop a new measure to assess self-efficacy in caregivers of people with advanced cancer. The development and testing of the new measure consisted of four separate, sequential phases: generation of issues, development of issues into items, pilot testing and field testing. In the generation of issues, 17 caregivers were interviewed to generate data. These data were analysed to generate codes, which were then systematically developed into items to construct the instrument. The instrument was pilot tested with 14 health professionals and five caregivers. It was then administered to a large sample for field testing to establish the psychometric properties, with established measures including the Brief Cope and the Family Appraisals for Caregiving Questionnaire for Palliative Care. Ninety-four caregivers completed the questionnaire booklet to establish the factor structure, reliability and validity. The factor analysis resulted in a 21-item, four-factor instrument, with the subscales being termed Resilience, Self-Maintenance, Emotional Connectivity and Instrumental Caregiving. The test-retest reliability and internal consistency were both excellent, ranging from 0.73 to 0.85 and 0.81 to 0.94, respectively. Six convergent and divergent hypotheses were made, and five were supported. This study has developed a new instrument to assess self-efficacy in caregivers of people with advanced cancer. The result is a four-factor, 21-item instrument with demonstrated reliability and validity. Copyright © 2012 John Wiley & Sons, Ltd.

  10. [The development of an oral biomechanical testing instrument].

    PubMed

    Zhang, X H; Sun, X D; Lin, Z

    2000-03-01

    An oral biomechanical testing instrument, which is portable, powered with batteries and controlled by single chip microcomputer, was described. The instrument was characterized by its multichannel, high accuracy, low power dissipation, wide rage of force measurement and stable performance. It can be used for acquisiting, displaying and storing data. And it may be expected to be an ideal instrument for oral biomechanical measurements.

  11. Research and Development on a Public Attitude Instrument for Stuttering

    ERIC Educational Resources Information Center

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  12. Acquisition of Airborne Sea Ice Remote Sensing Data with CULPIS-X: an Instrument Mounted on a US Coast Guard C-130

    NASA Astrophysics Data System (ADS)

    Tschudi, M. A.; Tooth, M.; Barton-Grimley, R. A.

    2016-12-01

    To obtain high-resolution observations of sea ice, we developed the University of Colorado LIDAR Profiler Instrument Suite - Extended (CULPIS-X). CULPIS-X, originally funded by NASA and currently supported by ONR, is being deployed in the flare tube of a US Coast Guard (USCG) C-130 aircraft, during Arctic Domain Awareness (ADA) flights from Kodiak, AK to the Arctic, in cooperation with the Coast Guard and with the Seasonal Ice Zone Remote Sensing (SIZRS, J. Morrison, PI) program. CULPIS-X (Figure 1) contains a LIDAR, digital camera, thermal infrared and hyperspectral radiometers, along with a GPS for aircraft altitude and an Inertial Measurement Unit (IMU) for aircraft attitude, and a computer to process and write the instrument data to SD cards. The package is designed to fly over Arctic sea ice for the purposes of measuring sea ice roughness, estimating sea ice thickness, and measuring ice surface temperature and reflectance. CULPIS-X had its inaugural flight aboard a C-130 out of USCG Air Station Sacramento in April 2016. This flight tested the structure of CULPIS-X, along with instrument readiness. The inaugural Arctic flight of CULPIS-X took place on June 15, 2016. The C-130 took off from Kodiak and flew towards Deadhorse, where it turned on to the 150W longitude line and proceeded north to 76N. The C-130 descended to a lower altitude ( 500 feet) during several flight segments along the 150W line, from Deadhorse to 76N and back. The lower altitude is required to obtain ULS LIDAR return pulses as they reflect off the ocean and sea ice. A similar flight was also performed on July 13, 2016. LIDAR data will be utilized to determine the surface roughness of the overflown ice pack. Furthermore, we will pick locations where open water occurred near or within the ice pack, to establish the freeboard of the ice pack, which will be used to estimate the sea ice thickness. More flights are scheduled for this season, in mid-Aug, Sept, and Oct, and are designed to overfly

  13. Classroom Social Capital: Development of a Measure of Instrumental Social Support within Academic Settings

    ERIC Educational Resources Information Center

    Shecter, Julie

    2009-01-01

    Many universities implement programs and interventions to increase students' perceived instrumental social support within the classroom setting, yet to date, no measures exist to adequately assess such perceptions. In response to this need, the current research developed an operational definition of instrumental classroom social support and also…

  14. The development and pilot testing of an instrument to measure nurses' working environment: the Nursing Context Index.

    PubMed

    Slater, Paul; McCormack, Brendan; Bunting, Brendan

    2009-01-01

    Evidence shows that adopting a person-centered approach to nursing alters the work environment, reduces anxiety levels among nurses in the long term, promotes teamwork among staff, and increases job satisfaction. However, few studies have attempted to quantify the outcomes from the adoption of person-centered nursing. The lack of outcome measurement is in part influenced by the lack of a standardized instrument to measure person-centered nursing. The aim of this study was to develop an instrument (the Nursing Context Index) to inform the development of person-centered nursing and outcomes arising. The Nursing Context Index (NCI) was developed through three stages. Stage 1 involved a systematic literature review to identify the key characteristics that needed to be considered in the instrument. Stage 2 involved the identification and selection of items for inclusion in the instrument identified through focus group discussions. A 19-construct instrument was developed. Face validity and content validity were gauged. In Stage 3, a pilot study (n = 23) was conducted to test the instrument. Measures of internal consistency were ensured using Cronbach's alpha. Criterion-related validity of the instrument was ensured through comparison between factors contained in the instrument. Findings show that the NCI is an accurate representation of the factors influenced by a clinical setting's progression to person-centered nursing. The factors were deemed appropriate to the clinical settings, and possessed face and content validity. Initial statistical findings confirm the validity and usability of the NCI. The process used for the development and testing of the instrument was found to be effective. The NCI was deemed to be an effective measure of factors influenced by the implementation of person-centered nursing and would help in redressing a scarcity of quantitative evidence to examine the benefits of nurses working in a person-centered manner.

  15. Nurses' Empowerment Scale for ICU patients' families: an instrument development study.

    PubMed

    Li, Hong; Liu, Ya-Lan; Qiu, Li; Chen, Qiao-Ling; Wu, Jing-Bing; Chen, Li-Li; Li, Na

    2016-09-01

    Family members provide essential support for ICU patients, contributing to their mental and physical recovery. Empowering ICU patients' families may help them overcome inadequacies and meet their own and patients' acknowledged needs. Nursing should understand and address patients' families' empowerment status. To develop a tool, the Nurses' Empowerment Scale for Intensive Care Unit (ICU) Patients' Families (NESIPF), to help ICU nursing staff assess the empowerment status of patients' families. Four-phase instrument development study. A 19-item instrument was initially generated based on literature review and interviews with family members of ICU patients. The Delphi research method was applied to gain expert opinion and consensus via rounds of questionnaires. A panel of 27 experts experienced in critical care medicine, nursing and psychology participated in two Delphi rounds and their input helped formulate an 18-item pretest instrument. Families of 20 patients were recruited to examine instrument readability. After a 2-week interval, another 20 patients' families were recruited to examine test-retest reliability. Two hundred questionnaires were then administered and analysed to examine the instrument's construct validity, criterion-related validity and internal consistency. Expert authority coefficients of two Delphi rounds reached 0·89 and 0·91. Kendall' W coefficients of 0·113 (P < 0·001) in round 1 and 0·220 (P < 0·001) in round 2 indicated slight to fair agreement among experts. Content validity index (CVI) reached 1·0 for 12 items; the CVI for item 13 was <0·7 so it was excluded. Cronbach's α coefficient was 0·92, indicating acceptable internal consistency reliability. The coefficient of internal consistency of each dimension was 0·717-0·921. The Pearson correlation coefficient >0·9 (P < 0·05) showed an acceptable test-retest reliability. The instrument has acceptable reliability and validity and can assess the empowerment status of families of

  16. Development of an Instrument for Measuring Clinicians’ Power Perceptions in the Workplace

    PubMed Central

    Bartos, Christa E.; Fridsma, Douglas B.; Butler, Brian S.; Penrod, Louis E.; Becich, Michael J.; Crowley, Rebecca S.

    2008-01-01

    We report on the development of an instrument to measure clinicians’ perceptions of their personal power in the workplace in relation to resistance to computerized physician order entry (CPOE). The instrument is based on French and Raven’s six bases of social power and uses a semantic differential methodology. A measurement study was conducted to determine the reliability and validity of the survey. The survey was administered online and distributed via a URL by email to 19 physicians, nurses, and health unit coordinators from a university hospital. Acceptable reliability was achieved by removing or moving some semantic differential word pairs used to represent the six power bases (alpha range from 0.76–0.89). The Semantic Differential Power Perception (SDPP) survey validity was tested against an already validated instrument and found to be acceptable (correlation range from 0.51–0.81). The SDPP survey instrument was determined to be both reliable and valid. PMID:18375189

  17. Development and test of a Microwave Ice Accretion Measurement Instrument (MIAMI)

    NASA Technical Reports Server (NTRS)

    Magenheim, B.; Rocks, J. K.

    1982-01-01

    The development of an ice accretion measurement instrument that is a highly sensitive, accurate, rugged and reliable microprocessor controlled device using low level microwave energy for non-instrusive real time measurement and recording of ice growth history, including ice thickness and accretion rate is discussed. Data is displayed and recorded digitally. New experimental data is presented, obtained with the instrument, which demonstrates its ability to measure ice growth on a two-dimensional airfoil. The device is suitable for aircraft icing protection. It may be mounted flush, non-intrusively, on any part of an aircraft skin including rotor blades and engine inlets.

  18. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Urgiles, E.; Wilcox, J. Z.; Toda, R.; Crisp, J.; George, T.

    2005-01-01

    Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

  19. Development and Testing of Assessment Instruments for Multidisciplinary Engineering Capstone Design Courses

    ERIC Educational Resources Information Center

    Gerlick, Robert Edward

    2010-01-01

    The research presented in this manuscript was focused on the development of assessments for engineering design outcomes. The primary goal was to support efforts by the Transferrable Integrated Design Engineering Education (TIDEE) consortium in developing assessment instruments for multidisciplinary engineering capstone courses. Research conducted…

  20. 14 CFR Appendix C to Part 141 - Instrument Rating Course

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... rating appropriate to the instrument rating for which the course applies prior to enrolling in the flight...) of this section appropriate to the instrument rating for which the course applies: (1) 30 hours of...) Aeronautical decision making and judgment; and (10) Crew resource management, to include crew communication and...

  1. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  2. Development of esMOCA RULA, Motion Capture Instrumentation for RULA Assessment

    NASA Astrophysics Data System (ADS)

    Akhmad, S.; Arendra, A.

    2018-01-01

    The purpose of this research is to build motion capture instrumentation using sensors fusion accelerometer and gyroscope to assist in RULA assessment. Data processing of sensor orientation is done in every sensor node by digital motion processor. Nine sensors are placed in the upper limb of operator subject. Development of kinematics model is done with Simmechanic Simulink. This kinematics model receives streaming data from sensors via wireless sensors network. The output of the kinematics model is the relative angular angle between upper limb members and visualized on the monitor. This angular information is compared to the look-up table of the RULA worksheet and gives the RULA score. The assessment result of the instrument is compared with the result of the assessment by rula assessors. To sum up, there is no significant difference of assessment by the instrument with an assessment by an assessor.

  3. Development and initial evaluation of an instrument to assess physiotherapists' clinical reasoning focused on clients' behavior change.

    PubMed

    Elvén, Maria; Hochwälder, Jacek; Dean, Elizabeth; Söderlund, Anne

    2018-05-01

    A systematically developed and evaluated instrument is needed to support investigations of physiotherapists' clinical reasoning integrated with the process of clients' behavior change. This study's aim was to develop an instrument to assess physiotherapy students' and physiotherapists' clinical reasoning focused on clients' activity-related behavior and behavior change, and initiate its evaluation, including feasibility and content validity. The study was conducted in three phases: 1) determination of instrument structure and item generation, based on a model, guidelines for assessing clinical reasoning, and existing measures; 2) cognitive interviews with five physiotherapy students to evaluate item understanding and feasibility; and 3) a Delphi process with 18 experts to evaluate content relevance. Phase 1 resulted in an instrument with four domains: Physiotherapist; Input from client; Functional behavioral analysis; and Strategies for behavior change. The instrument consists of case scenarios followed by items in which key features are identified, prioritized, or interpreted. Phase 2 resulted in revisions of problems and approval of feasibility. Phase 3 demonstrated high level of consensus regarding the instrument's content relevance. This feasible and content-validated instrument shows potential for use in investigations of physiotherapy students' and physiotherapists' clinical reasoning, however continued development and testing are needed.

  4. Development of Assessment Instrument of Critical Thinking in Physics at Senior High School

    NASA Astrophysics Data System (ADS)

    Sugiarti, T.; Kaniawati, I.; Aviyanti, L.

    2017-02-01

    The result of preliminary study shows that the assessment of physics in school did not train students’ critical thinking skill. The assessment instrument just measured low cognitive aspects. Supposedly, critical thinking skill is trained in the assessment activity. The study aims to determine the characteristics and the quality of critical thinking skill instrument. It employs descriptive-qualitative method with research and development as the research design. The research participants are 35 students involved in the limited trial and 188 students in the wider trial from three public senior high school in Ciamis which in high level school. The data was collected through expert validation, tests and interviews. The results indicate that the characteristics of the assessment instrument of critical thinking skill is open-ended. The instrument fulfills some indicators namely analyzing argument, deduction, induction, and display information in the form of scenario, text, graphic and table. In addition, the data processing through V4 Anates program shows that the instrument reliability achieves 0.67 with high interpretation of 0.67 and the validity is 0.47 with enough interpretation. Thus, the assessment instrument of critical thinking skill in the form of open-ended essay meets the criteria of quality test, so it can use as instrument of assessment critical thinking skill.

  5. Formative Evaluation of the Early Development Instrument: Progress and Prospects

    ERIC Educational Resources Information Center

    Keating, Daniel P.

    2007-01-01

    This article is a commentary for the special issue on the Early Development Instrument (EDI), a community tool to assess children's school readiness and developmental outcomes at a group level. The EDI is administered by kindergarten teachers, who assess their kindergarten students on 5 developmental domains: physical health and well-being, social…

  6. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    PubMed Central

    Zamanzadeh, Vahid; Ghahramanian, Akram; Rassouli, Maryam; Abbaszadeh, Abbas; Alavi-Majd, Hamid; Nikanfar, Ali-Reza

    2015-01-01

    Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment). At the first step, domain determination, sampling (item generation) and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items), informational support (seven items), emotional support (five items), problem solving (seven items), patient activation (10 items), intimacy/friendship (six items) and spirituality strengthening (14 items). Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument. PMID:26161370

  7. Operational challenges for astronomical instrumentation in Antarctica: results from five years of environmental monitoring of AMICA at Dome C

    NASA Astrophysics Data System (ADS)

    Dolci, Mauro; Valentini, Angelo; Tavagnacco, Daniele; Di Cianno, Amico; Straniero, Oscar

    2016-08-01

    The Antarctic Plateau is one of the best observing sites on Earth, especially for infrared astronomy. The extremely low temperatures (down to -80°C), the low pressure (around 650 mbar) and the very dry atmosphere (PWV less than 1 mm) allow for a very clear and dark sky, as well as for a very low instrumental background. These unique properties, however, make it also very difficult to install and operate astronomical instrumentation. AMICA (Antarctic Multiband Infrared CAmera) is an instrument especially designed for Antarctic operation, whose installation at Dome C has been completed in 2013. Since then it has been continuously working over the last five years, monitoring and controlling in particular the environmental and operating conditions through a dedicated application, its Environmental Control System (ECS). The recorded behavior of AMICA highlighted a set of peculiar aspects of the site that are hard to consider a priori. Although mechanical and electronic COTS components can reliably work in thermally insulated and controlled boxes, simple insulation causes their overheating because of the air dryness and rarefaction which make the heat transfer extremely inefficient. Heat removal is also a real problem when managing heavy-duty devices like cryocoolers, whose excess power removal needs to be fast and efficient. Finally, the lack of an electrical ground generates a wide variety of transient electrical and electromagnetic phenomena which often make electronic instrumentation very unstable. A list of new recommendations is therefore presented, as a guideline for future astronomical instruments operating in Antarctica.

  8. Instrumentation Research and Support Services.

    DTIC Science & Technology

    1985-09-30

    of a sensitive 3-axis 47 accelerometer within an ejectable instrumented sphere, has permitted a simple "Piggy- back" experimental program, in which a...45 3.3.3 Experimental PC M Ranging Test Flight.................... 46 3.3.4 C N2 Support Services .................................. 47 *3.4...led to the development of automated testing under control of a microcomputer, which per’iits elaborate sampling and analysis with hard-copy printout

  9. Development and Validation of Teaching Practice Evaluation Instrument for Assessing Chemistry Students' Teaching Skills

    ERIC Educational Resources Information Center

    Ezeudu, F. O.; Chiaha, G. T. U.; Eze, J. U.

    2013-01-01

    The study was designed to develop and factorially validate an instrument for measuring teaching practice skills of chemistry student-teachers in University of Nigeria, Nsukka. Two research questions guided the study. The design of the study was instrumentation. All the chemistry student-teachers in the Department of Science Education, University…

  10. Study on virtual instrument developing system based on intelligent virtual control

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Cheng, Fabin; Qin, Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  11. The development of an instrument for evaluating clinical teachers: involving stakeholders to determine content validity.

    PubMed

    Stalmeijer, Renée E; Dolmans, Diana H J M; Wolfhagen, Ineke H A P; Muijtjens, Arno M M; Scherpbier, Albert J J A

    2008-01-01

    Research indicates that the quality of supervision strongly influences the learning of medical students in clinical practice. Clinical teachers need feedback to improve their supervisory skills. The available instruments either lack a clear theoretical framework or are not suitable for providing feedback to individual teachers. We developed an evaluation instrument based on the 'cognitive apprenticeship model'. The aim was to estimate the content validity of the developed instrument. Item relevance was rated on a five-point scale (1 = highly irrelevant, 5 = highly relevant) by three groups of stakeholders in undergraduate clinical teaching: educationalists (N = 12), doctors (N = 16) and students (N = 12). Additionally, stakeholders commented on content, wording and omission of items. The items were generally rated as very relevant (Mean = 4.3, SD = 0.38, response = 95%) and any differences between the stakeholder groups were small. The results led to elimination of 4 items, rewording of 13 items and addition of 1 item. The cognitive apprenticeship model appears to offer a useful framework for the development of an evaluation instrument aimed at providing feedback to individual clinical teachers on the quality of student supervision. Further studies in larger populations will have to establish the instrument's statistical validity and generalizability.

  12. Assessment of Patient-Reported Outcome Instruments to Assess Chronic Low Back Pain.

    PubMed

    Ramasamy, Abhilasha; Martin, Mona L; Blum, Steven I; Liedgens, Hiltrud; Argoff, Charles; Freynhagen, Rainer; Wallace, Mark; McCarrier, Kelly P; Bushnell, Donald M; Hatley, Noël V; Patrick, Donald L

    2017-06-01

     To identify patient-reported outcome (PRO) instruments that assess chronic low back pain (cLBP) symptoms (specifically pain qualities) and/or impacts for potential use in cLBP clinical trials to demonstrate treatment benefit and support labeling claims.  Literature review of existing PRO measures.  Publications detailing existing PRO measures for cLBP were identified, reviewed, and summarized. As recommended by the US Food & Drug Administration (FDA) PRO development guidance, standard measurement characteristics were reviewed, including development history, psychometric properties (validity and reliability), ability to detect change, and interpretation of observed changes.  Thirteen instruments were selected and reviewed: Low Back Pain Bothersomeness Scale, Neuropathic Pain Symptom Inventory, PainDETECT, Pain Quality Assessment Scale Revised, Revised Short Form McGill Pain Questionnaire, Low Back Pain Impact Questionnaire, Oswestry Disability Index, Pain Disability Index, Roland-Morris Disability Questionnaire, Brief Pain Inventory and Brief Pain Inventory Short Form, Musculoskeletal Outcomes Data Evaluation and Management System Spine Module, Orebro Musculoskeletal Pain Questionnaire, and the West Haven-Yale Multidimensional Pain Inventory Interference Scale. The instruments varied in the aspects of pain and/or impacts that they assessed, and none of the instruments fulfilled all criteria for use in clinical trials to support labeling claims based on recommendations outlined in the FDA PRO guidance.  There is an unmet need for a validated PRO instrument to evaluate cLBP-related symptoms and impacts for use in clinical trials. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. Development of the Test Of Astronomy STandards (TOAST) Assessment Instrument

    NASA Astrophysics Data System (ADS)

    Slater, Timothy F.; Slater, S. J.

    2008-05-01

    Considerable effort in the astronomy education research (AER) community over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing the AER discipline so that researchers could establish the initial knowledge state of students as well as to attempt measure some of the impacts of innovative instructional interventions. Unfortunately, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. This was not done in oversight, but rather as a result of the relative youth of AER as a discipline. Now that several important science education reform documents exist and are generally accepted by the AER community, we are in a position to develop, validate, and disseminate a new assessment instrument which is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. In response, researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science & Math Teaching Center (UWYO SMTC) have designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for courses with learning goals tightly aligned to the consensus goals of our community.

  14. The development and psychometrical evaluation of a set of instruments to evaluate the effectiveness of diabetes patient education.

    PubMed

    Duprez, Veerle; De Pover, Marleen; De Spiegelaere, Marc; Beeckman, Dimitri

    2014-02-01

    To develop a set of psychometrically sound instruments to assess knowledge, self-management and self-efficacy of diabetic patients. Furthermore, a survey to evaluate the satisfaction about diabetes education for patients was developed and tested. Treatment and secondary prevention of diabetes require a complex combination of care components. Patients' education has been accepted to improve diabetes knowledge, self-management and self-efficacy. Psychometrically sound instruments are needed to measure these patient-centred outcomes. Psychometric instrument validation. The first phase included a systematic literature review to develop the instruments. Content validity was evaluated using a two-round Delphi procedure involving diabetes experts. The content validity of the instruments was excellent. In a second phase, a convenience sample of 188 diabetic patients in two hospitals in one specific care region in Belgium participated in the psychometric evaluation. The criterion-related validity and internal consistency reliability were evaluated. The study produced a 21-item knowledge instrument, reflecting knowledge about 'glycemic control' and 'medico-social management aspects'. The self-management instrument included 32 statements, reflecting 'treatment and compliance' and 'general lifestyle'. The self-efficacy instrument included 30 items, reflecting 'nutrition', 'treatment' and 'regimen'. The patient satisfaction survey included 36 items, reflecting satisfaction about the relationship among the diabetes specialist, the diabetes educator, podiatrist and dietician. An instrument set with sound psychometric characteristics was developed to assess knowledge, self-management and self-efficacy of diabetic patients. Future studies should focus on the association between the instrument outcomes and clinical patient outcomes. The current instrument can support the design of educational interventions and training programmes and reduce inconsistencies in the information that

  15. Improvement of older driver safety through self-evaluation : the development of a self-evaluation instrument

    DOT National Transportation Integrated Search

    2000-03-01

    This research project was designed to increase safety in the older driver population by developing and testing a self-evaluation instrument. The instrument is intended for drivers who may be starting to experience declines in driving abilities or los...

  16. Development of ECT/UT inspection system for bottom mounted instrumentation nozzle of PWR reactor vessels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanaka, H.; Fukui, S.; Iwahashi, Y.

    1994-12-31

    The development of inspection technique and tool for Bottom Mounted Instrument (BMI) nozzle of PWR plant was performed for countermeasure of leakage accident at incore instrument nozzle of Hamaoka-1 (BWR). MHI achieved the following development, of which object was PWR Plant R/V: (1) development of ECT/UT Multi-sensored Probe; (2) development of Inspection System (3) development of Data Processing System. The Inspection System had been functionally tested using full scale mock-up. As the result of the functional test, this system was confirmed to be very effective, and assumed to be hopeful for the actual application on site.

  17. The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire.

    PubMed

    McAlinden, Colm; Pesudovs, Konrad; Moore, Jonathan E

    2010-11-01

    To develop an instrument to measure subjective quality of vision: the Quality of Vision (QoV) questionnaire. A 30-item instrument was designed with 10 symptoms rated in each of three scales (frequency, severity, and bothersome). The QoV was completed by 900 subjects in groups of spectacle wearers, contact lens wearers, and those having had laser refractive surgery, intraocular refractive surgery, or eye disease and investigated with Rasch analysis and traditional statistics. Validity and reliability were assessed by Rasch fit statistics, principal components analysis (PCA), person separation, differential item functioning (DIF), item targeting, construct validity (correlation with visual acuity, contrast sensitivity, total root mean square [RMS] higher order aberrations [HOA]), and test-retest reliability (two-way random intraclass correlation coefficients [ICC] and 95% repeatability coefficients [R(c)]). Rasch analysis demonstrated good precision, reliability, and internal consistency for all three scales (mean square infit and outfit within 0.81-1.27; PCA >60% variance explained by the principal component; person separation 2.08, 2.10, and 2.01 respectively; and minimal DIF). Construct validity was indicated by strong correlations with visual acuity, contrast sensitivity and RMS HOA. Test-retest reliability was evidenced by a minimum ICC of 0.867 and a minimum 95% R(c) of 1.55 units. The QoV Questionnaire consists of a Rasch-tested, linear-scaled, 30-item instrument on three scales providing a QoV score in terms of symptom frequency, severity, and bothersome. It is suitable for measuring QoV in patients with all types of refractive correction, eye surgery, and eye disease that cause QoV problems.

  18. SOLAR-B Mission Extreme Ultraviolet (EUV) Imaging Spectrometer (EIS) Instrument Components

    NASA Technical Reports Server (NTRS)

    Doschek, George A.

    2001-01-01

    This Monthly Progress Report covers the reporting period through June 2001, Phase C/D, Detailed Design and Development Through Launch Plus Thirty Days, for selected components and subsystems of the Extreme ultraviolet Imaging Spectrometer (EIS) instrument, hereafter referred to as EIS Instrument Components. This document contains the program status through the reporting period and forecasts the status for the upcoming reporting period.

  19. Solar-B Mission Extreme Ultraviolet (EUV) Imaging Spectrometer (EIS) Instrument Components

    NASA Technical Reports Server (NTRS)

    Doschek, George A.

    2002-01-01

    This Monthly Progress Report covers the reporting period August 2002 of the Detailed Design and Development through Launch plus Thirty Days, Phase C/D, for selected components and subsystems of the Extreme ultraviolet Imaging Spectrometer (EIS) instrument, hereafter referred to as EIS Instrument Components. This document contains the program status through the reporting period and forecasts the status for the upcoming reporting period.

  20. SOLAR-B Mission Extreme Ultraviolet (EUV) Imaging Spectrometer (EIS) Instrument Components

    NASA Technical Reports Server (NTRS)

    Doschek, George A.

    2001-01-01

    This Monthly Progress Report covers the reporting period July 2001 of the Detailed Design and Development through Launch plus Thirty Days, Phase C/D, for selected components and subsystems of the Extreme Ultraviolet Imaging Spectrometer (EIS) instrument, hereafter referred to as EIS Instrument Components. This document contains the program status through the reporting period and forecasts the status for the upcoming reporting period.

  1. Development of an Instrument for Evaluating Anxiety Caused by Cognitive Conflict

    NASA Astrophysics Data System (ADS)

    Kim, Yeounsoo; Bao, Lei

    2005-09-01

    Physics learning situations often involve many cognitive conflicts between a student's present understandings and new information being learned. Cognitive conflict is known as an important factor in conceptual change. Therefore, it is important to help physics teachers and students develop skills and knowledge for more effective conflict management. However there is no readily available method to monitor the existence and features of cognitive conflicts that students may encounter during their learning. We focus the study on student anxiety caused by cognitive conflict so that we can improve student motivation. This study is targeted to develop an easy-to-use instrument that can be implemented in the classrooms to monitor student anxiety in cognitive conflict situations and the effects on student motivation. In this paper, we will discuss the structure of this instrument and show results from using this tool in our Physics by Inquiry class.

  2. Development of the Multi-Angle Stratospheric Aerosol Radiometer (MASTAR) Instrument

    NASA Astrophysics Data System (ADS)

    DeLand, M. T.; Colarco, P. R.; Kowalewski, M. G.; Gorkavyi, N.; Ramos-Izquierdo, L.

    2017-12-01

    Aerosol particles in the stratosphere ( 15-25 km altitude), both produced naturally and perturbed by volcanic eruptions and anthropogenic emissions, continue to be a source of significant uncertainty in the Earth's energy budget. Stratospheric aerosols can offset some of the warming effects caused by greenhouse gases. These aerosols are currently monitored using measurements from the Ozone Mapping and Profiling Suite (OMPS) Limb Profiler (LP) instrument on the Suomi NPP satellite. In order to improve the sensitivity and spatial coverage of these aerosol data, we are developing an aerosol-focused compact version of the OMPS LP sensor called Multi-Angle Stratospheric Aerosol Radiometer (MASTAR) to fly on a 3U Cubesat satellite, using a NASA Instrument Incubator Program (IIP) grant. This instrument will make limb viewing measurements of the atmosphere in multiple directions simultaneously, and uses only a few selected wavelengths to reduce size and cost. An initial prototype version has been constructed using NASA GSFC internal funding and tested in the laboratory. Current design work is targeted towards a preliminary field test in Spring 2018. We will discuss the scientific benefits of MASTAR and the status of the project.

  3. A Psychometric Approach to the Development of a 5E Lesson Plan Scoring Instrument for Inquiry-Based Teaching

    ERIC Educational Resources Information Center

    Goldston, M. Jenice; Dantzler, John; Day, Jeanelle; Webb, Brenda

    2013-01-01

    This research centers on the psychometric examination of the structure of an instrument, known as the 5E Lesson Plan (5E ILPv2) rubric for inquiry-based teaching. The instrument is intended to measure an individual's skill in developing written 5E lesson plans for inquiry teaching. In stage one of the instrument's development, an exploratory…

  4. Integrated development facility for the calibration of low-energy charged particle flight instrumentation

    NASA Technical Reports Server (NTRS)

    Biddle, A. P.; Reynolds, J. M.

    1986-01-01

    The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

  5. Thin Film Physical Sensor Instrumentation Research and Development at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Fralick, Gustave C.

    2006-01-01

    A range of thin film sensor technology has been demonstrated enabling measurement of multiple parameters either individually or in sensor arrays including temperature, strain, heat flux, and flow. Multiple techniques exist for refractory thin film fabrication, fabrication and integration on complex surfaces and multilayered thin film insulation. Leveraging expertise in thin films and high temperature materials, investigations for the applications of thin film ceramic sensors has begun. The current challenges of instrumentation technology are to further develop systems packaging and component testing of specialized sensors, further develop instrumentation techniques on complex surfaces, improve sensor durability, and to address needs for extreme temperature applications. The technology research and development ongoing at NASA Glenn for applications to future launch vehicles, space vehicles, and ground systems is outlined.

  6. Wind Tunnel Test Technique and Instrumentation Development at LaRC

    NASA Technical Reports Server (NTRS)

    Putnam, Lawrence E.

    1999-01-01

    LaRC has an aggressive test technique development program underway. This program has been developed using 3rd Generation R&D management techniques and is a closely coordinated program between suppliers and wind tunnel operators- wind tunnel customers' informal input relative to their needs has been an essential ingredient in developing the research portfolio. An attempt has been made to balance this portfolio to meet near term and long term test technique needs. Major efforts are underway to develop techniques for determining model wing twist and location of boundary layer transition in the NTF (National Transonic Facility). The foundation of all new instrumentation developments, procurements, and upgrades will be based on uncertainty analysis.

  7. Development of Long-term Datasets from Satellite BUV Instruments: The "Soft" Calibration Approach

    NASA Technical Reports Server (NTRS)

    Bhartia, Pawan K.; Taylor, Steven; Jaross, Glen

    2005-01-01

    The first BUV instrument was launched in April 1970 on NASA's Nimbus4 satellite. More than a dozen instruments, broadly based on the same principle, but using very different technologies, have been launched in the last 35 years on NASA, NOAA, Japanese and European satellites. In this paper we describe the basic principles of the "soft" calibration approach that we have successfully applied to the data from many of these instruments to produce a consistent long-term record of total ozone, ozone profile and aerosols. This approach is based on using accurate radiative transfer models and assumed/known properties of the atmosphere in ultraviolet to derive calibration parameters. Although the accuracy of the results inevitably depends upon how well the assumed atmospheric properties are known, the technique has several built-in cross- checks that improve the robustness of the method. To develop further confidence in the data the soft calibration technique can be combined with data collected from few well- calibrated ground-based instruments. We will use examples from past and present BUV instruments to show how the method works.

  8. The MetOp second generation 3MI instrument

    NASA Astrophysics Data System (ADS)

    Manolis, Ilias; Grabarnik, Semen; Caron, Jérôme; Bézy, Jean-Loup; Loiselet, Marc; Betto, Maurizio; Barré, Hubert; Mason, Graeme; Meynart, Roland

    2013-10-01

    The MetOp-SG programme is a joint Programme of EUMETSAT and ESA. ESA develops the prototype MetOp-SG satellites (including associated instruments) and procures, on behalf of EUMETSAT, the recurrent satellites (and associated instruments). Two parallel, competitive phase A/B1 studies for MetOp Second Generation (MetOp-SG) have been concluded in May 2013. The implementation phases (B2/C/D/E) are planned to start the first quarter of 2014. ESA is responsible for instrument design of six missions, namely Microwave Sounding Mission (MWS), Scatterometer mission (SCA), Radio Occultation mission (RO), Microwave Imaging mission (MWI), Ice Cloud Imager (ICI) and Multi-viewing, Multi-channel, Multi-polarisation imaging mission (3MI). The paper will present the main performances of the 3MI instrument and will highlight the performance improvements with respect to its heritage derived by the POLDER instrument, such as number of spectral channels and spectral range coverage, swath and ground spatial resolution. The engineering of some key performance requirements (multi-viewing, polarisation sensitivity, straylight etc.) will also be discussed. The results of the feasibility studies will be presented together with the programmatics for the instrument development. Several pre-development activities have been initiated to retire highest risks and to demonstrate the ultimate performances of the 3MI optics. The scope, objectives and current status of those activities will be presented. Key technologies involved in the 3MI instrument design and implementation are considered to be: the optical design featuring aspheric optics, the implementation of broadband Anti Reflection coatings featuring low polarisation and low de-phasing properties, the development and qualification of polarisers with acceptable performances as well as spectral filters with good uniformities over a large clear aperture.

  9. Perception of competence in middle school physical education: instrument development and validation.

    PubMed

    Scrabis-Fletcher, Kristin; Silverman, Stephen

    2010-03-01

    Perception of Competence (POC) has been studied extensively in physical activity (PA) research with similar instruments adapted for physical education (PE) research. Such instruments do not account for the unique PE learning environment. Therefore, an instrument was developed and the scores validated to measure POC in middle school PE. A multiphase design was used consisting of an intensive theoretical review, elicitation study, prepilot study, pilot study, content validation study, and final validation study (N=1281). Data analysis included a multistep iterative process to identify the best model fit. A three-factor model for POC was tested and resulted in root mean square error of approximation = .09, root mean square residual = .07, goodness offit index = .90, and adjusted goodness offit index = .86 values in the acceptable range (Hu & Bentler, 1999). A two-factor model was also tested and resulted in a good fit (two-factor fit indexes values = .05, .03, .98, .97, respectively). The results of this study suggest that an instrument using a three- or two-factor model provides reliable and valid scores ofPOC measurement in middle school PE.

  10. Recent development of the Multi-Grid detector for large area neutron scattering instruments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guerard, Bruno

    2015-07-01

    Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternativemore » techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with

  11. Advising on Preferred Reporting Items for patient-reported outcome instrument development: the PRIPROID.

    PubMed

    Hou, Zheng-Kun; Liu, Feng-Bin; Fang, Ji-Qian; Li, Xiao-Ying; Li, Li-Juan; Lin, Chu-Hua

    2013-03-01

    The reporting of patient-reported outcomes (PRO) instrument development is vital for both researchers and clinicians to determine its validity, thus, we propose the Preferred Reporting Items for PRO Instrument Development (PRIPROID) to improve the quality of reports. Abiding by the guidance published by the Enhancing the QUAlity and Transparency Of health Research (EQUATOR) Network, we had performed 6 steps for items development: identified the need for a guideline, performed a literature review, obtained funding for the guideline initiative, identified participants, conducted a Delphi exercise and generated a list of PRIPROID items for consideration at the face-to-face meeting. Twenty three items subheadings under 7 topics were included: title and structured abstract, rationale, objectives, intention, eligibility criteria, conceptual framework, items generation, response options, scoring, times, administrative modes, burden assessment, properties assessment, statistical methods, participants, main results, and additional analysis, summary of evidence, limitations, clinical attentions, and conclusions, item pools or final form, and funding. The PRIPROID contains many elements of the PRO research, and this assists researchers to report their results more accurately and to a certain degree use this instrument to evaluate the quality of the research methods.

  12. Development and validation of the Australian Aboriginal racial identity and self-esteem survey for 8-12 year old children (IRISE_C).

    PubMed

    Kickett-Tucker, C S; Christensen, D; Lawrence, D; Zubrick, S R; Johnson, D J; Stanley, F

    2015-10-24

    In Australia, there is little empirical research of the racial identity of Indigenous children and youth as the majority of the current literature focuses on adults. Furthermore, there are no instruments developed with cultural appropriateness when exploring the identity and self-esteem of the Australian Aboriginal population, especially children. The IRISE_C (Racial Identity and Self-Esteem of children) inventory was developed to explore the elements of racial identity and self-esteem of urban, rural and regional Aboriginal children. This paper describes the development and validation of the IRISE_C instrument with over 250 Aboriginal children aged 8 to 12 years. A pilot of the IRISE C instrument was combined with individual interviews and was undertaken with 35 urban Aboriginal children aged 8-12 years. An exploratory factor analysis was performed to refine the survey and reduce redundant items in readiness for the main study. In the main study, the IRISE C was employed to 229 Aboriginal children aged 6-13 years across three sites (rural, regional and urban) in Western Australia. An exploratory factor analysis using Principal axis factoring was used to assess the fit of items and survey structure. A confirmatory factor analysis was then employed using LISREL (diagonally weighted least squares) to assess factor structures across domains. Internal consistency and reliability of subscales were assessed using Cronbach's co-efficient alpha. The pilot testing identified two key concepts - children's knowledge of issues related to their racial identity, and the importance, or salience, that they attach to these issues. In the main study, factor analyses showed two clear factors relating to: Aboriginal culture and traditions; and a sense of belonging to an Aboriginal community. Principal Axis Factoring of the Knowledge items supported a 2-factor solution, which explained 38.7% of variance. Factor One (Aboriginal culture) had a Cronbach's alpha of 0.835; Factor 2 (racial

  13. Developing a Scale for Strategies Used during the Practice and Learning of Instrumental Music

    ERIC Educational Resources Information Center

    Uygun, Mehtap Aydiner; Kilinçer, Özlem

    2017-01-01

    The purpose of this study is to develop a valid and reliable scale to identify the strategies students who study instrumental music use during the practice and learning of instrumental music based on their own responses. The study group comprised of 358 students studying music education in five universities in the academic year of 2015 to 2016.…

  14. Capturing Career Reflections: Construction of an Instrument to Explore Careers and Career Development

    ERIC Educational Resources Information Center

    McDonald, Kimberly S.; Hite, Linda M.; Mansour-Cole, Dina

    2006-01-01

    This study describes the development and validation of an instrument to tap employee reflections on career interests, needs and career development opportunities. Item construction was based on issues identified in previous qualitative research and themes prevalent in recent HRD career development literature. Pilot data for an exploratory factor…

  15. Microcomputer control soft tube measuring-testing instrument

    NASA Astrophysics Data System (ADS)

    Zhou, Yanzhou; Jiang, Xiu-Zhen; Wang, Wen-Yi

    1993-09-01

    Soft tube are key and easily spoiled parts used by the vehicles in the transportation with large numbers. Measuring and testing of the tubes were made by hands for a long time. Cooperating with Harbin Railway Bureau recently we have developed a new kind of automatical measuring and testing instrument In the paper the instrument structure property and measuring principle are presented in details. Centre of the system is a singlechip processor INTEL 80C31 . It can collect deal with data and display the results on LED. Furthermore it brings electromagnetic valves and motors under control. Five soft tubes are measured and tested in the same time all the process is finished automatically. On the hardware and software counter-electromagnetic disturbance methods is adopted efficiently so the performance of the instrument is improved significantly. In the long run the instrument is reliable and practical It solves a quite difficult problem in the railway transportation.

  16. Development and validation of a trustworthy multisource feedback instrument to support nurse appraisals.

    PubMed

    Crossley, James G M

    2015-01-01

    Nurse appraisal is well established in the Western world because of its obvious educational advantages. Appraisal works best with many sources of information on performance. Multisource feedback (MSF) is widely used in business and in other clinical disciplines to provide such information. It has also been incorporated into nursing appraisals, but, so far, none of the instruments in use for nurses has been validated. We set out to develop an instrument aligned with the UK Knowledge and Skills Framework (KSF) and to evaluate its reliability and feasibility across a wide hospital-based nursing population. The KSF framework provided a content template. Focus groups developed an instrument based on consensus. The instrument was administered to all the nursing staff in 2 large NHS hospitals forming a single trust in London, England. We used generalizability analysis to estimate reliability, response rates and unstructured interviews to evaluate feasibility, and factor structure and correlation studies to evaluate validity. On a voluntary basis the response rate was moderate (60%). A failure to engage with information technology and employment-related concerns were commonly cited as reasons for not responding. In this population, 11 responses provided a profile with sufficient reliability to inform appraisal (G = 0.7). Performance on the instrument was closely and significantly correlated with performance on a KSF questionnaire. This is the first contemporary psychometric evaluation of an MSF instrument for nurses. MSF appears to be as valid and reliable as an assessment method to inform appraisal in nurses as it is in other health professional groups. © 2015 The Alliance for Continuing Education in the Health Professions, the Society for Academic Continuing Medical Education, and the Council on Continuing Medical Education, Association for Hospital Medical Education.

  17. Development of the CLAES instrument aperture door system

    NASA Technical Reports Server (NTRS)

    Stubbs, D. M.

    1990-01-01

    The design, assembly, and test processes followed in developing a space-qualified aperture door system are described. A blackbody calibration source is mounted inside the door, requiring the assembly to open and close a minimum of 150 cycles for instrument recalibration. Within the door system are four separate mechanisms, three of which are redundant; a pyro launch latch, a hinge bearing assembly, and a pair of pivot mechanisms. Decoupling devices within the pivot mechanisms allow an active drive unit to automatically overdrive a failed drive unit. The door is also stowable for possible Shuttle retrieval and re-entry. Illustrations and photographs of the flight hardware help acquaint the reader with the design. The aim is to pass on lessons learned in all phases of developing this spaceflight mechanism.

  18. Development and application of an instrument for analysis of bone structure on radiographs.

    PubMed

    Xu, S; Liu, S; Bao, K

    1997-01-01

    An instrument used for quantitative assessment of trabecular structure of radius on radiograph including trabecular number and trabecular width was developed using a microdensitometer and a single-chip microcomputer. The device is characterized by its high sensitivity, good reproducibility, convenience and economy. The results obtained with the instrument were significantly correlated to actual bone mineral content. This device can be used for the diagnosis of osteoporosis, fluorosis, rickets and bone damages caused by cadmium.

  19. An Undergraduate Student Instrumentation Project (USIP) to Develop New Instrument Technology to Study the Auroral Ionosphere and Stratospheric Ozone Layer Using Ultralight Balloon Payloads

    NASA Astrophysics Data System (ADS)

    Nowling, M.; Ahmad, H.; Gamblin, R.; Guala, D.; Hermosillo, D.; Pina, M.; Marrero, E.; Canales, D. R. J.; Cao, J.; Ehteshami, A.; Bering, E. A., III; Lefer, B. L.; Dunbar, B.; Bias, C.; Shahid, S.

    2015-12-01

    This project is currently engaging twelve undergraduate students in the process of developing new technology and instrumentation for use in balloon borne geospace investigations in the auroral zone. Motivation stems from advances in microelectronics and consumer electronic technology. Given the technological innovations over the past 20 years it now possible to develop new instrumentation to study the auroral ionosphere and stratospheric ozone layer using ultralight balloon payloads for less than 6lbs and $3K per payload. The University of Houston Undergraduate Student Instrumentation Project (USIP) team has built ten such payloads for launch using 1500 gm latex weather balloons deployed in Houston, TX, Fairbanks, AK, and as well as zero pressure balloons launched from northern Sweden. The latex balloon project will collect vertical profiles of wind velocity, temperature, electrical conductivity, ozone, and odd nitrogen. This instrument payload will also produce profiles of pressure, electric field, and air-earth electric current. The zero pressure balloons will obtain a suite of geophysical measurements including: DC electric field, electric field and magnetic flux, optical imaging, total electron content of ionosphere via dual-channel GPS, X-ray detection, and infrared/UV spectroscopy. Students flew payloads with different combinations of these instruments to determine which packages are successful. Data collected by these instruments will be useful in understanding the nature of electrodynamic coupling in the upper atmosphere and how the global earth system is changing. Twelve out of the launched fifteen payloads were successfully launched and recovered. Results and best practices learned from lab tests and initial Houston test flights will be discussed.

  20. A levitation instrument for containerless study of molten materials.

    PubMed

    Nordine, Paul C; Merkley, Dennis; Sickel, Jeffrey; Finkelman, Steve; Telle, Rainer; Kaiser, Arno; Prieler, Robert

    2012-12-01

    A new aero-acoustic levitation instrument (AAL) has been installed at the Institute for Mineral Engineering at RWTH University in Aachen, Germany. The AAL employs acoustically stabilized gas jet levitation with laser-beam heating and melting to create a contact-free containerless environment for high temperature materials research. Contamination-free study of liquids is possible at temperatures in excess of 3000 °C and of undercooled liquids at temperatures far below the melting point. Digital control technology advances the art of containerless experiments to obtain long-term levitation stability, allowing new experiments in extreme temperature materials research and to study operation of the levitation instrument itself. Experiments with liquid Al(2)O(3) at temperatures more than 3200 °C, 1200 °C above the melting point, and with liquid Y(3)Al(5)O(12) far below the melting point are reported. Fast pyrometry and video recording instruments yield crystallization rates in undercooled liquid Al(2)O(3) as a function of temperature. Levitation of dense liquid HfO(2) at temperatures above 2900 °C is demonstrated. Capabilities are described for resonant frequency matching in the three-axis acoustic positioning system, acoustic control of sample spin, and position control of standing wave nodes to stabilize levitation under changing experimental conditions. Further development and application of the levitation technology is discussed based on the results of experiments and modeling of instrument operations.

  1. A levitation instrument for containerless study of molten materials

    NASA Astrophysics Data System (ADS)

    Nordine, Paul C.; Merkley, Dennis; Sickel, Jeffrey; Finkelman, Steve; Telle, Rainer; Kaiser, Arno; Prieler, Robert

    2012-12-01

    A new aero-acoustic levitation instrument (AAL) has been installed at the Institute for Mineral Engineering at RWTH University in Aachen, Germany. The AAL employs acoustically stabilized gas jet levitation with laser-beam heating and melting to create a contact-free containerless environment for high temperature materials research. Contamination-free study of liquids is possible at temperatures in excess of 3000 °C and of undercooled liquids at temperatures far below the melting point. Digital control technology advances the art of containerless experiments to obtain long-term levitation stability, allowing new experiments in extreme temperature materials research and to study operation of the levitation instrument itself. Experiments with liquid Al2O3 at temperatures more than 3200 °C, 1200 °C above the melting point, and with liquid Y3Al5O12 far below the melting point are reported. Fast pyrometry and video recording instruments yield crystallization rates in undercooled liquid Al2O3 as a function of temperature. Levitation of dense liquid HfO2 at temperatures above 2900 °C is demonstrated. Capabilities are described for resonant frequency matching in the three-axis acoustic positioning system, acoustic control of sample spin, and position control of standing wave nodes to stabilize levitation under changing experimental conditions. Further development and application of the levitation technology is discussed based on the results of experiments and modeling of instrument operations.

  2. Spinal Instrumentation in Growing Children Retards the Natural Development of Pelvic Incidence.

    PubMed

    Bekmez, Senol; Demirkiran, Halil Gokhan; Dede, Ozgur; Atici, Yunus; Balioglu, Mehmet Bulent; Kruyt, Moyo; Ward, Timothy; Yazici, Muharrem

    2016-09-22

    Pelvic incidence increases gradually throughout growth until skeletal maturity. Growing rod instrumentation has been suggested to have a stabilizing effect on the development of the normal sagittal spinal alignment. The purpose of this study is to determine the effect of fixed sagittal plane caused by dual growing rod instrumentation on the natural progression of sagittal spinopelvic parameters in children with idiopathic or idiopathic-like early onset scoliosis. Hospital records of children with growing rod instrumentation from 4 separate institutions were reviewed retrospectively. Inclusion criteria were idiopathic or idiopathic-like early onset scoliosis, treatment with dual growing rods with lower instrumented vertebra L4 or upper and more than 2 years of follow-up. Instrumentation levels, magnitudes of major curve, thoracic kyphosis (T2-T12), lumbar lordosis (L1-S1) and pelvic incidence were recorded from preoperative and postoperative standing whole-spine radiographs. Estimated pelvic incidence was also calculated for each patient as if their spines had not been instrumented using the previous normative data. A total of 37 patients satisfied the inclusion criteria. Average age at initial surgery was 7.4±1.8 years (range, 4 to 12 y). Mean follow-up time was 71±26 months (range, 27 to 120 mo). Mean preoperative Cobb angle of 59±13.5 (range, 30 to 86) degrees was reduced to 35.1±17.5 (range, 11 to 78) degrees at the last follow-up. Mean preoperative T2-T12 kyphosis angle was 46.2±14.9 degrees (range, 22 to 84 degrees). At the latest follow-up, it was 44.8±16.2 degrees (range, 11 to 84 degrees) (P=0.93). Mean L1-S1 lordosis angle was 50.5±10.7 degrees (range, 30 to 72 degrees) preoperatively. At the latest follow-up, mean L1-S1 lordosis angle was 48.8±12.7 degrees (range, 26 to 74 degrees) (P=0.29). Mean preoperative pelvic incidence was 45.7±7.9 degrees (range, 30 to 68 degrees). At the latest follow-up, it was 46.7±8.4 degrees (range, 34 to 72 degrees

  3. Development of an embedded instrument for autofocus and polarization alignment of polarization maintaining fiber

    NASA Astrophysics Data System (ADS)

    Feng, Di; Fang, Qimeng; Huang, Huaibo; Zhao, Zhengqi; Song, Ningfang

    2017-12-01

    The development and implementation of a practical instrument based on an embedded technique for autofocus and polarization alignment of polarization maintaining fiber is presented. For focusing efficiency and stability, an image-based focusing algorithm fully considering the image definition evaluation and the focusing search strategy was used to accomplish autofocus. For improving the alignment accuracy, various image-based algorithms of alignment detection were developed with high calculation speed and strong robustness. The instrument can be operated as a standalone device with real-time processing and convenience operations. The hardware construction, software interface, and image-based algorithms of main modules are described. Additionally, several image simulation experiments were also carried out to analyze the accuracy of the above alignment detection algorithms. Both the simulation results and experiment results indicate that the instrument can achieve the accuracy of polarization alignment <±0.1 deg.

  4. Students' Socioscientific Reasoning and Decision-making on Energy-related Issues—Development of a measurement instrument

    NASA Astrophysics Data System (ADS)

    Sakschewski, Mark; Eggert, Sabina; Schneider, Susanne; Bögeholz, Susanne

    2014-09-01

    The concept of energy is one key component of science education curricula worldwide. While it is still being taught in many science classrooms from a mainly conceptual knowledge perspective, the need to frame the concept of energy as a socioscientific issue and implement it in the context of citizenship education and education for sustainable development, is getting more and more explicit. As we will be faced with limited fossil fuels and the consequences of global climate change in the future, students have to be supported in becoming literate citizens who are able to reach informed energy-related decisions. In this article, we focus on students' reasoning and decision-making processes about socioscientific energy-related issues. In more detail, we developed a paper-and-pencil measurement instrument to assess secondary school students' competencies in this domain. The functioning of the measurement instrument was analysed with a sample of 850 students from grades 6, 8, 10 and 12 using item response theory. Findings show that the measurement instrument functions in terms of reliability and validity. Concerning student ability, elaborate reasoning and decision-making was characterised by the use of trade-offs and the ability to weigh arguments and to reflect on the structure of reasoning and decision-making processes. The developed measurement instrument provides a complement for existing test instruments on conceptual knowledge about the concept of energy. It aims to contribute to a change in teaching about energy, especially in physics education in the sense of education for sustainable development.

  5. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    PubMed Central

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  6. Recent progress in development of infrared laser based instruments for real-time ambient measurements of isotopologues of carbon dioxide, water, methane, nitrous oxide and carbon monoxide

    NASA Astrophysics Data System (ADS)

    Nelson, David; McManus, Barry; Shorter, Joanne; Zahniser, Mark; Ono, Shuhei

    2014-05-01

    The capacity for real time precise in situ measurements of isotopic ratios of a variety of trace gases at ambient concentrations continues to create new opportunities for the study of the exchanges and fluxes of gases in the environment. Aerodyne Research has made rapid progress in laser based instruments since our introduction in 2007 of the first truly field worthy instrument for real time measurements of isotopologues of carbon dioxide. We have focused on two instrument design platforms, with either one or two lasers. Absorption cells with more than 200 meters path length allow precise measurements of trace gases with low ambient concentrations. Most of our systems employ mid infrared quantum cascade lasers. However, recently available 3 micron antimonide based diode lasers are also proving useful for isotopic measurements. By substituting different lasers and detectors, we can simultaneously measure the isotopic composition of a variety of gases, including: H2O, CO2, CH4, N2O and CO. Our newest instrument for true simultaneous measurement of isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) has (1 s) precision better than 0.1 per mil for both ratios. The availability of 10 Hz measurements allows measurement of isotopic fluxes via eddy correlation. The single laser instrument fits in a 19 inch rack and is only 25 cm tall. A two laser instrument is larger, but with that instrument we can also measure clumped isotopes of CO2, with 1 second precisions of: 2.3 per mil for 13C18O16O, and 6.7 per mil for 13C17O16O. The sample size for such a measurement corresponds to 0.2 micromole of pure CO2. Another variation on the two laser instrument simultaneously measures isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) and H2O (H216O, H218O, HD16O). Preliminary results for water ratio precisions (in 1s) are 0.1 per mil for H218O and 0.3 per mil for HD16O, simultaneous (1 s) precisions for isotopologues of CO2 of ~0.1 per mil. Methane, nitrous oxide and carbon monoxide have such

  7. Development and validation of an instrument to assess imminent risk of homelessness among veterans.

    PubMed

    Montgomery, Ann Elizabeth; Fargo, Jamison D; Kane, Vincent; Culhane, Dennis P

    2014-01-01

    Veterans are overrepresented within the homeless population compared with their non-veteran counterparts, particularly when controlling for poverty. The U.S. Department of Veterans Affairs (VA) aims to prevent new episodes of homelessness by targeting households at greatest risk; however, there are no instruments that systematically assess veterans' risk of homelessness. We developed and tested a brief screening instrument to identify imminent risk of homelessness among veterans accessing VA health care. The study team developed initial assessment items, conducted cognitive interviews with veterans experiencing homelessness, refined pilot items based on veterans' and experts' feedback and results of psychometric analyses, and assigned weights to items in the final instrument to indicate a measure of homelessness risk. One-third of veterans who responded to the field instrument reported imminent risk of homelessness (i.e., housing instability in the previous 90 days or expected in the next 90 days). The reliability coefficient for the instrument was 0.85, indicating good internal consistency. Veterans who had a recent change in income, had unpaid housing expenses, were living temporarily with family and friends, needed help to get or keep housing, and had poor rental and credit histories were more likely to report a risk of homelessness than those who did not. This study provides the field with an instrument to identify individuals and households at risk of or experiencing homelessness, which is necessary to prevent and end homelessness. In addition, it supports VA's investment in homelessness prevention and rapid rehousing services for veterans who are experiencing or are at risk for homelessness.

  8. Instrument Design of the Large Aperture Solar UV Visible and IR Observing Telescope (SUVIT) for the SOLAR-C Mission

    NASA Astrophysics Data System (ADS)

    Suematsu, Y.; Katsukawa, Y.; Shimizu, T.; Ichimoto, K.; Takeyama, N.

    2012-12-01

    We present an instrumental design of one major solar observation payload planned for the SOLAR-C mission: the Solar Ultra-violet Visible and near IR observing Telescope (SUVIT). The SUVIT is designed to provide high-angular-resolution investigation of the lower solar atmosphere, from the photosphere to the uppermost chromosphere, with enhanced spectroscopic and spectro-polarimetric capability in wide wavelength regions from 280 nm (Mg II h&k lines) to 1100 nm (He I 1083 nm line) with 1.5 m class aperture and filtergraphic and spectrographic instruments.

  9. Development of functional oral health literacy assessment instruments: application of literacy and cognitive theories.

    PubMed

    Bridges, Susan M; Parthasarathy, Divya S; Au, Terry K F; Wong, Hai Ming; Yiu, Cynthia K Y; McGrath, Colman P

    2014-01-01

    This paper describes the development of a new literacy assessment instrument, the Hong Kong Oral Health Literacy Assessment Task for Paediatric Dentistry (HKOHLAT-P). Its relationship to literacy theory is analyzed to establish content and face validity. Implications for construct validity are examined by analyzing cognitive demand to determine how "comprehension" is measured. Key influences from literacy assessment were identified to analyze item development. Cognitive demand was analyzed using an established taxonomy. The HKOHLAT-P focuses on the functional domain of health literacy assessment. Items had strong content and face validity reflecting established principles from modern literacy theory. Inclusion of new text types signified relevant developments in the area of new literacies. Analysis of cognitive demand indicated that this instrument assesses the "comprehension" domain, specifically the areas of factual and procedural knowledge, with some assessment of conceptual knowledge. Metacognitive knowledge was not assessed. Comprehension tasks assessing patient health literacy predominantly examine functional health literacy at the lower levels of comprehension. Item development is influenced by the fields of situated and authentic literacy. Inclusion of content regarding multiliteracies is suggested for further research. Development of functional health literacy assessment instruments requires careful consideration of the clinical context in determining construct validity. © 2013 American Association of Public Health Dentistry.

  10. The Early Development Instrument: An Examination of Convergent and Discriminant Validity

    ERIC Educational Resources Information Center

    Hymel, Shelley; LeMare, Lucy; McKee, William

    2011-01-01

    The convergent and discriminant validity of the Early Development Instrument (EDI), a teacher-rated assessment of children's "school readiness", was investigated in a multicultural sample of 267 kindergarteners (53% male). Teachers evaluations on the EDI, both overall and in five domains (physical health/well-being, social competence,…

  11. TELICS—A Telescope Instrument Control System for Small/Medium Sized Astronomical Observatories

    NASA Astrophysics Data System (ADS)

    Srivastava, Mudit K.; Ramaprakash, A. N.; Burse, Mahesh P.; Chordia, Pravin A.; Chillal, Kalpesh S.; Mestry, Vilas B.; Das, Hillol K.; Kohok, Abhay A.

    2009-10-01

    For any modern astronomical observatory, it is essential to have an efficient interface between the telescope and its back-end instruments. However, for small and medium-sized observatories, this requirement is often limited by tight financial constraints. Therefore a simple yet versatile and low-cost control system is required for such observatories to minimize cost and effort. Here we report the development of a modern, multipurpose instrument control system TELICS (Telescope Instrument Control System) to integrate the controls of various instruments and devices mounted on the telescope. TELICS consists of an embedded hardware unit known as a common control unit (CCU) in combination with Linux-based data acquisition and user interface. The hardware of the CCU is built around the ATmega 128 microcontroller (Atmel Corp.) and is designed with a backplane, master-slave architecture. A Qt-based graphical user interface (GUI) has been developed and the back-end application software is based on C/C++. TELICS provides feedback mechanisms that give the operator good visibility and a quick-look display of the status and modes of instruments as well as data. TELICS has been used for regular science observations since 2008 March on the 2 m, f/10 IUCAA Telescope located at Girawali in Pune, India.

  12. The Teaching with Technology Instrument: Effectively Measuring Where Teachers Are and Planning for Staff Development.

    ERIC Educational Resources Information Center

    Atkins, Nancy E.; Vasu, Ellen S.

    1998-01-01

    Presents an instrument for planning for staff development to help identify how much teachers know about technology and its integration into the classroom. The Teaching with Technology Instrument's (TTI's) 46 items are grouped in three areas: writing and communication skills, information access and management, and construction and multimedia. The…

  13. Development of bridge-scour instrumentation for inspection and maintenance personnel

    USGS Publications Warehouse

    Mueller, David S.; Landers, Mark N.; ,

    1993-01-01

    Inspecting bridges and monitoring scour during high flow can improve public transportation safety by providing early identification of scour and stream stability problems at bridges. Most bridge-inspection data are collected during low flow, when scour holes may have refilled. More than 25 percent of the States that responded to a questionnaire identified lack of adequate methodology and/or equipment as reasons for not collecting scour data during high-flow conditions. Therefore, the U.S. Geological Survey (USGS), in cooperation with the Federal Highway Administration, has begun to develop instrumentation for measuring scour that could be used by inspection and maintenance personnel during high-flow conditions. A variety of instruments and techniques for measuring scour were tested and evaluated in real-time bridge-scour data-collection studies by the USGS. In the National Scour study, fathometers were found to be superior to sounding weights and will be the primary bed-measuring instrument. The ability of low-cost fathometers and fish finders to locate the bed accurately is being evaluated. Simple and efficient methods for deploying the transducer during floods are also important for a successful measurement. The information and additional testing are being used to design new, portable scour-measuring systems.

  14. Development of quality of life instrument for urban poor in the northeast of Thailand.

    PubMed

    Surit, Phrutthinun; Laohasiriwong, Wongsa; Sanchaisuriya, Pattara; Schelp, Frank Perter

    2008-09-01

    Measuring the quality of life is important for evaluation and prediction of life and social care needs. To evaluate Quality of Life (QOL) in an urban poor population in northeast of Thailand, the Urban Poor Quality of Life (UPQOL) instrument was developed To develop an initial instrument to measure urban poor QOL. The development was started with literature review and investigated in urban poor communities. The results were transformed into the items required to build a structured questionnaire. Five hundred twenty three subjects, representatives of urban poor, were selected to test this instrument. Descriptive statistics described feature of items and the samples, exploratory factor analysis conducted the items score, and confirmatory factor analysis conducted the construct validity. The result found that the UPQOL instrument consisted of nine domains (education, income and employment, environment, health, infrastructure, security and safety, shelter and housing, civil society and political, and human rights domains) with egien value rank from 1.5 to 4.2 and 61 items with the factor loading rank from 0.41 to 0.82. The internal consistency was 0.92. The correlation between items to domain ranged from 0.30 to 0.72 and domains to overall QOL ranged from 0.27 to 0.84. Confirmatory factor analysis showed that the structure fit all domains well. Domains and overall structure were good with CFI (> 0.95). The internal consistency value ranged from 0.73-0.93. UPQOL scores were able to discriminate groups of subjects with differences levels of QOL. The UPQOL instrument is conceptually valid. The results support good validity and reliability. It forms the basis for future testing and application in other settings.

  15. Review of manual control methods for handheld maneuverable instruments.

    PubMed

    Fan, Chunman; Dodou, Dimitra; Breedveld, Paul

    2013-06-01

    By the introduction of new technologies, surgical procedures have been varying from free access in open surgery towards limited access in minimal access surgery. Improving access to difficult-to-reach anatomic sites, e.g. in neurosurgery or percutaneous interventions, needs advanced maneuverable instrumentation. Advances in maneuverable technology require the development of dedicated methods enabling surgeons to stay in direct, manual control of these complex instruments. This article gives an overview of the state-of-the-art in the development of manual control methods for handheld maneuverable instruments. It categorizes the manual control methods in three levels: a) number of steerable segments, b) number of Degrees Of Freedom (DOF), and c) coupling between control motion of the handle and steering motion of the tip. The literature research was completed by using Web of Science, Scopus and PubMed. The study shows that in controlling single steerable segments, direct as well as indirect control methods have been developed, whereas in controlling multiple steerable segments, a gradual shift can be noticed from parallel and serial control to integrated control. The development of multi-segmented maneuverable instruments is still at an early stage, and an intuitive and effective method to control them has to become a primary focus in the domain of minimal access surgery.

  16. Posterior Rigid Instrumentation of C7: Surgical Considerations and Biomechanics at the Cervicothoracic Junction. A Review of the Literature.

    PubMed

    Bayoumi, Ahmed B; Efe, Ibrahim E; Berk, Selim; Kasper, Ekkehard M; Toktas, Zafer Orkun; Konya, Deniz

    2018-03-01

    The cervicothoracic junction is a challenging anatomic transition in spine surgery. It is commonly affected by different types of diseases that may significantly impair stability in this region. The seventh cervical vertebra (C7) is an atypical cervical vertebra with unique anatomic features compared to subaxial cervical spine (C3 to C6). C7 has relatively broader laminae, larger pedicles, smaller lateral masses, and a long nonbifid spinous process. These features allow a variety of surgical methods for performing posterior rigid instrumentation in the form of different types of screws, such as lateral mass screws, pedicle screws, transfacet screws, and intralaminar screws. Many biomechanical studies on cadavers have evaluated and compared different types of implants at C7. We reviewed PubMed/Medline by using specific combinations of keywords to summarize previously published articles that examined C7 posterior rigid instrumentation thoroughly in an experimental fashion on patients or cadavers with additional descriptive radiologic parameters for evaluation of the optimum surgical technique for each type. A total of 44 articles were reported, including 22 articles that discussed anatomic considerations (entry points, sagittal and axial trajectories, and features of screws) and another 22 articles that discussed the relevant biomechanical testing at this transitional region if C7 was directly involved in terms of receiving posterior rigid implants. C7 can accommodate different types of screws, which can provide additional benefits and risks based on availability of bony purchase, awareness of surgical technique, biomechanics, and anatomic considerations. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Design and development of the Sentinel-2 Multi Spectral Instrument and satellite system

    NASA Astrophysics Data System (ADS)

    Chorvalli, Vincent; Cazaubiel, Vincent; Bursch, Stefan; Welsch, Mario; Sontag, Heinz; Martimort, Philippe; Del Bello, Umberto; Sy, Omar; Laberinti, Paolo; Spoto, François

    2010-10-01

    2A and Sentinel-2B satellites currently under development will ensure systematic global acquisition of all land and coastal waters in the visible and short-wave infrared spectral domain with a 5 day revisit time at the equator. The Multi Spectral Instrument is a push-broom imager providing imagery in 13 spectral channels with spatial resolutions ranging from 10 m to 60 m and a swath width of 290 Km, larger than SPOT and Landsat. The instrument features a full field of view calibration device, a silicon carbide Three Mirror Anastigmat telescope with mirror dimensions up to 600 mm, specific filter stripe assemblies, newly developed Si-CMOS and HgCDTe detectors and a low noise wavelet compression video electronics. The 1.4 Tbits/s raw image date rate is reduced down to 490 Mbits/s at the output of the instrument to cope with the overall system transmission capability. The Sentinel-2 program has entered in the CD phase in 2009. Launch of Sentinel-2A satellite is scheduled for 2013.

  18. Sensory and instrumental texture measurements for assessing grape seed parameters during fruit development.

    PubMed

    Letaief, Hend; Maury, Chantal; Symoneaux, Ronan; Siret, René

    2013-08-15

    The evolution of the sensory and instrumental properties of grape seeds was investigated during berry development, with a focus on the effects of the harvest season and growing location. The sensory and instrumental texture analyses gave a consistent description of the ripening process. Moreover, the effect of maturation on the seed sensory descriptors was clearly influenced by the harvest season, and astringency was the most appropriate sensory attribute for the assessment of grape seed ripening. Except for seed cracking, which was positively correlated with fracturability (R = 0.69) and toughness (R = 0.68) in 2006, the compression parameters were generally not correlated with the sensory textural attributes but were more likely correlated with other sensory attributes such as astringency and vegetal aroma. The compression indices showed a logarithmic behaviour pattern during grape development, and seed stiffness was shown to be the most valuable textural index for parcel discrimination and identification of the optimal grape harvesting date. This research showed that both seed sensory attributes and instrumental texture properties are indicators of grape ripening. However, these properties could be affected by the harvest season and growing location. As no clear correlation was found between the seed sensory attributes and instrumental texture parameters, a revision of the sensory method available in the literature could be suggested. © 2013 Society of Chemical Industry.

  19. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    PubMed

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  20. Development and Validation of a Consumer Quality Assessment Instrument for Dentistry.

    ERIC Educational Resources Information Center

    Johnson, Jeffrey D.; And Others

    1990-01-01

    This paper reviews the literature on consumer involvement in dental quality assessment, argues for inclusion of this information in quality assessment measures, outlines a conceptual model for measuring dental consumer quality assessment, and presents data relating to the development and validation of an instrument based on the conceptual model.…

  1. The New Microwave Temperature and Humidity Profiler (MTHP) Airborne Instrument

    NASA Astrophysics Data System (ADS)

    Lim, B.; Bendig, R.; Denning, R.; Pandian, P.; Read, W. G.; Tanner, A.

    2016-12-01

    The Jet Propulsion Laboratory (JPL) has developed a next generation sensor, the Microwave Temperature and Humidity Profiler (MTHP) for use on airborne platforms. The instrument measures the 60 GHz oxygen band and 183 GHz water vapor band, and scans ahead of the aircraft flight path, allowing for atmospheric retrievals above and below the aircraft, to generate vertical profiles. The millimeter wave microwave receivers utilize low noise amplifiers made on the 35 nm indium phosphide (InP) High Electron Mobility Transistors (HEMTs) process that offer low noise figures ( 4 dB). Continuous calibration is performed with a novel rotating drum, through an aperture matched to the measurement frequencies, with two external targets - one at ambient and another heated to 55oC. The instrument performs a scan of the vertical structure of the atmosphere and calibration targets every 1.5 seconds The instrument has recently flown on the Gulfstream 2 in June 2016 and participated in the NCAR ARISTO C-130 flight test campaign in August 2016. The performance of the instrument during these campaigns, will be presented.

  2. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    ERIC Educational Resources Information Center

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  3. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    PubMed

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  4. Rasch Analysis for Instrument Development: Why, When, and How?

    PubMed Central

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to construct “Wright maps” to explain the meaning of a test score or survey score and develop alternative forms of tests and surveys. Rasch techniques provide a mechanism by which the quality of life sciences–related tests and surveys can be optimized and the techniques can be used to provide a context (e.g., what topics a student has mastered) when explaining test and survey results. PMID:27856555

  5. Development of Mirror Modules for the ART-XC Instrument

    NASA Technical Reports Server (NTRS)

    Gubarev, M.; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Pavlinsky, M.; Lapshov, I.

    2012-01-01

    The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART -XC instrument on board the Spectrum-Roentgen-Gamma Mission under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) ART-XC will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Currently, four of the modules are being fabricated by the Marshall Space Flight Center (MSFC.) Each MSFC module provides an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. We will present a status of the ART x-ray module development at MSFC.

  6. Guidelines for Successful Use and Communication of Instrument Heritage in Early Mission Development with a Focus on Spectrometers

    NASA Technical Reports Server (NTRS)

    Baker, Elizabeth E.

    2012-01-01

    Heritage is important for both cost and risk related issues and as such, it is heavily discussed in NASA proposal evaluations. If used and communicated efficiently, heritage can lower both the perception of risk and the associated costs. Definitions of heritage vary between engineering, cost, and scientific communities, but when applied appropriately, heritage provides a benefit to the proposed mission. By making an instrument at least once before, the cost of producing it again can be reduced. The time and effort needed to develop the instrument concept and test the product represent an expense that can be lowered through the use of a previously built and developed instrument. This same thought can be applied when using a flight spare or build-to-print model of the heritage instrument. The lowered perception of risk is a result of the confidence gained in the instrument through successful use in the target environment. This is extremely important in early mission development to the evaluation board. This analysis will use JPL-managed proposals from 2003 to 2011, including Discovery, New Frontiers, and Mars Scout missions. Through the examination of these proposals and their associated debriefs, a set of guidelines have been created for successful use and communication of instrument heritage in early mission development

  7. Development and evaluation of an instrumented linkage system for total knee surgery.

    PubMed

    Walker, Peter S; Wei, Chih-Shing; Forman, Rachel E; Balicki, M A

    2007-10-01

    The principles and application of total knee surgery using optical tracking have been well demonstrated, but electromagnetic tracking may offer further advantages. We asked whether an instrumented linkage that attaches directly to the bone can maintain the accuracy of the optical and electromagnetic systems but be quicker, more convenient, and less expensive to use. Initial testing using a table-mounted digitizer to navigate a drill guide for placing pins to mount a cutting guide demonstrated the feasibility in terms of access and availability. A first version (called the Mark 1) instrumented linkage designed to fix directly to the bone was constructed and software was written to carry out a complete total knee replacement procedure. The results showed the system largely fulfilled these goals, but some surgeons found that using a visual display for pin placement was difficult and time consuming. As a result, a second version of a linkage system (called the K-Link) was designed to further develop the concept. User-friendly flexible software was developed for facilitating each step quickly and accurately while the placement of cutting guides was facilitated. We concluded that an instrumented linkage system could be a useful and potentially lower-cost option to the current systems for total knee replacement and could possibly have application to other surgical procedures.

  8. Towards a Generic and Adaptive System-On-Chip Controller for Space Exploration Instrumentation

    NASA Technical Reports Server (NTRS)

    Iturbe, Xabier; Keymeulen, Didier; Yiu, Patrick; Berisford, Dan; Hand, Kevin; Carlson, Robert; Ozer, Emre

    2015-01-01

    This paper introduces one of the first efforts conducted at NASA’s Jet Propulsion Laboratory (JPL) to develop a generic System-on-Chip (SoC) platform to control science instruments that are proposed for future NASA missions. The SoC platform is named APEX-SoC, where APEX stands for Advanced Processor for space Exploration, and is based on a hybrid Xilinx Zynq that combines an FPGA and an ARM Cortex-A9 dual-core processor on a single chip. The Zynq implements a generic and customizable on-chip infrastructure that can be reused with a variety of instruments, and it has been coupled with a set of off-chip components that are necessary to deal with the different instruments. We have taken JPL’s Compositional InfraRed Imaging Spectrometer (CIRIS), which is proposed for NASA icy moons missions, as a use-case scenario to demonstrate that the entire data processing, control and interface of an instrument can be implemented on a single device using the on-chip infrastructure described in this paper. We show that the performance results achieved in this preliminary version of the instrumentation controller are sufficient to fulfill the science requirements demanded to the CIRIS instrument in future NASA missions, such as Europa.

  9. Development and validation of an international appraisal instrument for assessing the quality of clinical practice guidelines: the AGREE project.

    PubMed

    2003-02-01

    International interest in clinical practice guidelines has never been greater but many published guidelines do not meet the basic quality requirements. There have been renewed calls for validated criteria to assess the quality of guidelines. To develop and validate an international instrument for assessing the quality of the process and reporting of clinical practice guideline development. The instrument was developed through a multi-staged process of item generation, selection and scaling, field testing, and refinement procedures. 100 guidelines selected from 11 participating countries were evaluated independently by 194 appraisers with the instrument. Following refinement the instrument was further field tested on three guidelines per country by a new set of 70 appraisers. The final version of the instrument contained 23 items grouped into six quality domains with a 4 point Likert scale to score each item (scope and purpose, stakeholder involvement, rigour of development, clarity and presentation, applicability, editorial independence). 95% of appraisers found the instrument useful for assessing guidelines. Reliability was acceptable for most domains (Cronbach's alpha 0.64-0.88). Guidelines produced as part of an established guideline programme had significantly higher scores on editorial independence and, after the publication of a national policy, had significantly higher quality scores on rigour of development (p<0.005). Guidelines with technical documentation had higher scores on that domain (p<0.0001). This is the first time an appraisal instrument for clinical practice guidelines has been developed and tested internationally. The instrument is sensitive to differences in important aspects of guidelines and can be used consistently and easily by a wide range of professionals from different backgrounds. The adoption of common standards should improve the consistency and quality of the reporting of guideline development worldwide and provide a framework to

  10. The Development of a Survey Instrument to Measure Transactional Distance in Secondary Blended Learning Environments

    ERIC Educational Resources Information Center

    Lane, Dennis Glenn

    2017-01-01

    The goal of this study was to develop a survey instrument to measure transactional distance in secondary blended learning environments. This study resulted in a 35-item survey instrument, the Blended Learning Assessment Scale of Transactional Distance (BLASTD), which was tested using a convenience sample of secondary students (n = 222) at a…

  11. Development of a Student-Centered Instrument to Assess Middle School Students' Conceptual Understanding of Sound

    ERIC Educational Resources Information Center

    Eshach, Haim

    2014-01-01

    This article describes the development and field test of the Sound Concept Inventory Instrument (SCII), designed to measure middle school students' concepts of sound. The instrument was designed based on known students' difficulties in understanding sound and the history of science related to sound and focuses on two main aspects of sound: sound…

  12. Developing Policy Instruments for Education in the EU: The European Qualifications Framework for Lifelong Learning

    ERIC Educational Resources Information Center

    Elken, Mari

    2015-01-01

    The European Qualifications Framework (EQF) for lifelong learning has been characterized as a policy instrument with a number of contested ideas, raising questions about the process through which such instruments are developed at European level. The introduction of the EQF is in this article examined through variations of neo-institutional theory:…

  13. Comparative Evaluation of Stress developed on Rotary Retreatment Instruments during Retrieval of Gutta-percha.

    PubMed

    Sihivahanan, Dhanasekaran; Reddy, T Vinay Kumar; Thomas, Anchu Rachel; Senthilnathan, Natarajan; Sivakumar, Murali; Shivanna, Sushmita

    2017-06-01

    The aim of the study is to compare the maximum stress distribution on the rotary retreatment instruments within the root canal at cervical, middle, and the apical one-third during retreatment of gutta-percha. A human mandibular premolar was scanned, and three-dimensional geometry of the root was reconstructed using finite element analysis (FEA) software package (ANSYS). The basic model was kept unchanged; tooth models were created using the same dimensions and divided into two groups as follows: Group I: ProTaper Universal retreatment system and group II: Mtwo rotary retreatment system. The stress distribution on the surface and within the retreatment files was analyzed numerically in the FEA package (ANSYS). The FEA analysis revealed that the retreatment instruments received the greatest stress in the cervical third, followed by the apical third and the middle third. The stress generated on the ProTaper Universal retreatment system was less when compared with the Mtwo retreatment files. The study concludes that the retreatment instruments undergo higher stress in the cervical third region, and further in vivo and in vitro studies are necessary to evaluate the relationship between instrument designs, stress distribution, residual stresses after use, and the torsional fracture of the retreatment instrument. The stress developed on the rotary retreatment instruments during retrieval of gutta-percha makes the instrument to get separated. There is no instrument system, i.e., suitable for all clinical situations and it is important to understand how the structural characteristics could influence the magnitude of stresses on the instrument to prevent its fracture in use.

  14. Developing an Instrument of Scientific Literacy Assessment on the Cycle Theme

    ERIC Educational Resources Information Center

    Rusilowati, Ani; Kurniawati, Lina; Nugroho, Sunyoto E.; Widiyatmoko, Arif

    2016-01-01

    The purpose of this study is to develop scientific literacy evaluation instrument that tested its validity, reliability, and characteristics to measure the skill of student's scientific literacy used four scientific literacy, categories as follow:science as a body of knowledge (category A), science as a way of thinking (category B), science as a…

  15. Mandolin Family Instruments

    NASA Astrophysics Data System (ADS)

    Cohen, David J.; Rossing, Thomas D.

    The mandolin family of instruments consists of plucked chordophones, each having eight strings in four double courses. With the exception of the mandobass, the courses are tuned in intervals of fifths, as are the strings in violin family instruments. The soprano member of the family is the mandolin, tuned G3-D4-A4-E5. The alto member of the family is the mandola, tuned C3-G3-D4-A4. The mandola is usually referred to simply as the mandola in the USA, but is called the tenor mandola in Europe. The tenor member of the family is the octave mandolin, tuned G2-D3-A3-E4. It is referred to as the octave mandolin in the USA, and as the octave mandola in Europe. The baritone member of the family is the mandocello, or mandoloncello, tuned C2-G2-D3-A3. A variant of the mandocello not common in the USA is the five-course liuto moderno, or simply liuto, designed for solo repertoire. Its courses are tuned C2-G2-D3-A3-E4. A mandobass was also made by more than one manufacturer during the early twentieth century, though none are manufactured today. They were fretted instruments with single string courses tuned E1-A1-D2-G2. There are currently a few luthiers making piccolo mandolins, tuned C4-G4-D5-A5.

  16. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    NASA Technical Reports Server (NTRS)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  17. Student engagement in mathematics: Development of instrument and validation of construct

    NASA Astrophysics Data System (ADS)

    Kong, Qi-Ping; Wong, Ngai-Ying; Lam, Chi-Chung

    2003-05-01

    Universal education has aggravated the problems of students' disengagement in learning, highlighting in particular, a greater range of motivations to learn and wider diversification in students' interests. Students' engagement with curriculum has become a crucial element in classroom learning. How we cultivate their involvement in the curriculum may be seen as being far more important than the epistemological consideration in the design of the school curriculum. Though aspects of behavioural, affective and cognitive engagements have been revealed in literature, we are still in need of a validated instrument that measures student engagement for further research. In the present study, an instrument of student engagement in the subject area of mathematics was developed through grounded research. Its validity was established by statistical methods

  18. The South African Astronomical Observatory instrumentation software architecture and the SHOC instruments

    NASA Astrophysics Data System (ADS)

    van Gend, Carel; Lombaard, Briehan; Sickafoose, Amanda; Whittal, Hamish

    2016-07-01

    Until recently, software for instruments on the smaller telescopes at the South African Astronomical Observatory (SAAO) has not been designed for remote accessibility and frequently has not been developed using modern software best-practice. We describe a software architecture we have implemented for use with new and upgraded instruments at the SAAO. The architecture was designed to allow for multiple components and to be fast, reliable, remotely- operable, support different user interfaces, employ as much non-proprietary software as possible, and to take future-proofing into consideration. Individual component drivers exist as standalone processes, communicating over a network. A controller layer coordinates the various components, and allows a variety of user interfaces to be used. The Sutherland High-speed Optical Cameras (SHOC) instruments incorporate an Andor electron-multiplying CCD camera, a GPS unit for accurate timing and a pair of filter wheels. We have applied the new architecture to the SHOC instruments, with the camera driver developed using Andor's software development kit. We have used this to develop an innovative web-based user-interface to the instrument.

  19. Childhood Maltreatment in South Korea: Retrospective Study

    ERIC Educational Resources Information Center

    Lee, Yanghee; Kim, Sangwon

    2011-01-01

    Objective: This study explored the prevalence of childhood maltreatment in South Korea using the retrospective version of ICAST and the associations between perceptions of abuse experienced during childhood and recent interpersonal problems and depression. Methods: 539 young persons, aged 18-24 years, from various universities, work places, and…

  20. Development of an instrument to measure the quality of documented nursing diagnoses, interventions and outcomes: the Q-DIO.

    PubMed

    Müller-Staub, Maria; Lunney, Margaret; Odenbreit, Matthias; Needham, Ian; Lavin, Mary Ann; van Achterberg, Theo

    2009-04-01

    This paper aims to report the development stages of an audit instrument to assess standardised nursing language. Because research-based instruments were not available, the instrument Quality of documentation of nursing Diagnoses, Interventions and Outcomes (Q-DIO) was developed. Standardised nursing language such as nursing diagnoses, interventions and outcomes are being implemented worldwide and will be crucial for the electronic health record. The literature showed a lack of audit instruments to assess the quality of standardised nursing language in nursing documentation. A qualitative design was used for instrument development. Criteria were first derived from a theoretical framework and literature reviews. Second, the criteria were operationalized into items and eight experts assessed face and content validity of the Q-DIO. Criteria were developed and operationalized into 29 items. For each item, a three or five point scale was applied. The experts supported content validity and showed 88.25% agreement for the scores assigned to the 29 items of the Q-DIO. The Q-DIO provides a literature-based audit instrument for nursing documentation. The strength of Q-DIO is its ability to measure the quality of nursing diagnoses and related interventions and nursing-sensitive patient outcomes. Further testing of Q-DIO is recommended. Based on the results of this study, the Q-DIO provides an audit instrument to be used in clinical practice. Its criteria can set the stage for the electronic nursing documentation in electronic health records.

  1. Development of the Kiel sensors for the EPD instrument on-board Solar Orbiter

    NASA Astrophysics Data System (ADS)

    Martin, Cesar; Wimmer-Schweingruber, Robert F.; Kulkarni, Shrinivasrao R.; Tammen, Jan; Terasa, Christoph; Yu, Jia; Boden, Sebastian; Steinhagen, Jan; Panitzsch, Lauri; Ravanbakhsh, Ali; Boettcher, Stephan; Hamann, Christian; Seimetz, Lars; Rodriguez-Pacheco, Javier

    2015-04-01

    Solar Orbiter is ESA's next solar and heliospheric mission, planned for launch in January 2017 and approaching the Sun as close as 0.28 AU. One of the Solar Orbiter's scientific questions is "How do the solar eruptions produce energetic particle radiation that fills the heliosphere?". The Energetic Particle Detector (EPD) will provide key measurements for this and the other Solar Orbiter science objectives. The EPD suite consists of four sensors measuring electrons, protons, and ions from helium to iron, and operating at partly overlapping energy ranges from 2 keV/n up to 200 MeV/n. The EPD sensors are: SupraThermal Electrons and Protons(STEP), Suprathermal Ion Spectrograph (SIS), Electron Proton Telescope (EPT) and High Energy Telescope (HET). Besides, the EPD sensors share the Instrument Control Unit (ICU). The University of Kiel in Germany is responsible for developing the EPT-HET, STEP and SIS sensors. Here we present the development status of the EPT-HET and STEP sensors focusing on the activities planned for the current phase C. Those activities include results of the integration and EMC tests on the EPT-HET and STEP Engineering Model (EM) and the assembly of the Proto Qualification Model (PQM).

  2. Development of the Kiel sensors for the EPD instrument on-board Solar Orbiter

    NASA Astrophysics Data System (ADS)

    Martin, Cesar; Wimmer-Schweingruber, Robert F.; Kulkarni, Shrinivasrao R.; Tammen, Jan; Terasa, Christoph; Yu, Jia; Boden, Sebastian; Steinhagen, Jan; Panitzsch, Lauri; Ravanbakhsh, Ali; Boettcher, Stephan; Hamann, Christian; Seimetz, Lars; Rodriguez-Pacheco, Javier

    2014-05-01

    Solar Orbiter is ESA's next solar and heliospheric mission, planned for launch in January 2017 and approaching the Sun as close as 0.28 AU. One of the Solar Orbiter's scientific questions is "How do the solar eruptions produce energetic particle radiation that fills the heliosphere?". The Energetic Particle Detector (EPD) will provide key measurements for this and the other Solar Orbiter science objectives. The EPD suite consists of four sensors measuring electrons, protons, and ions from helium to iron, and operating at partly overlapping energy ranges from 2 keV/n up to 200 MeV/n. The EPD sensors are: SupraThermal Electrons and Protons(STEP), Suprathermal Ion Spectrograph (SIS), Electron Proton Telescope (EPT) and High Energy Telescope (HET). Besides, the EPD sensors share the Instrument Control Unit (ICU). The University of Kiel in Germany is responsible for developing the EPT-HET, STEP and SIS sensors. Here we present the development status of the EPT-HET and STEP sensors focusing on the activities planned for the current phase C. Those activities include results of the environmental tests on the EPT-HET Structural Thermal Model (STM) and the assembly of the Engineering Model (EM).

  3. Development of Physics Attitude Scale (PAS): An Instrument to Measure Students' Attitudes toward Physics

    ERIC Educational Resources Information Center

    Kaur, Daisy; Zhao, Yi

    2017-01-01

    The present study is focused on the detailed description of Physics Attitude Scale (PAS) to measure students' attitudes toward physics. The development of this new instrument involved extensive interviews with both the experts as well as the students. This was followed by expert reviews and pilot testing of the instrument. The duly revised draft…

  4. Development of a Symptom-Based Patient-Reported Outcome Instrument for Functional Dyspepsia: A Preliminary Conceptual Model and an Evaluation of the Adequacy of Existing Instruments.

    PubMed

    Taylor, Fiona; Reasner, David S; Carson, Robyn T; Deal, Linda S; Foley, Catherine; Iovin, Ramon; Lundy, J Jason; Pompilus, Farrah; Shields, Alan L; Silberg, Debra G

    2016-10-01

    The aim was to document, from the perspective of the empirical literature, the primary symptoms of functional dyspepsia (FD), evaluate the extent to which existing questionnaires target those symptoms, and, finally, identify any missing evidence that would impact the questionnaires' use in regulated clinical trials to assess treatment efficacy claims intended for product labeling. A literature review was conducted to identify the primary symptoms of FD and existing symptom-based FD patient-reported outcome (PRO) instruments. Following a database search, abstracts were screened and articles were retrieved for review. The primary symptoms of FD were organized into a conceptual model and the PRO instruments were evaluated for conceptual coverage as well as compared against evidentiary requirements presented in the FDA's PRO Guidance for Industry. Fifty-six articles and 16 instruments assessing FD symptoms were reviewed. Concepts listed in the Rome III criteria for FD (n = 7), those assessed by existing FD instruments (n = 34), and symptoms reported by patients in published qualitative research (n = 6) were summarized in the FD conceptual model. Except for vomiting, all of the identified symptoms from the published qualitative research reports were also specified in the Rome III criteria. Only three of the 16 instruments, the Dyspepsia Symptom Severity Index (DSSI), Nepean Dyspepsia Index (NDI), and Short-Form Nepean Dyspepsia Index (SF-NDI), measure all seven FD symptoms defined by the Rome III criteria. Among these three, each utilizes a 2-week recall period and 5-point Likert-type scale, and had evidence of patient involvement in development. Despite their coverage, when these instruments were evaluated in light of regulatory expectations, several issues jeopardized their potential qualification for substantiation of a labeling claim. No existing PRO instruments that measured all seven symptoms adhered to the regulatory principles necessary to support product

  5. Practical SQUID Instrument for Nondestructive Testing

    NASA Technical Reports Server (NTRS)

    Tralshawala, N.; Claycomb, J. R.; Miller, John H., Jr.

    1997-01-01

    We report on the development of a scanning eddy-current imaging system designed to detect deep subsurface flaws in conducting materials. A high transition temperature (high-T c) superconducting quantum interference device (SQUID) magnetometer is employed to provide the required sensitivity at low frequencies, while a combination of small cylindrical high-Tc superconducting and A-metal shields enable the instrument to be scanned in a magnetically noisy environment, rather than the object under test. The shields are arranged to prevent unwanted excitation and ambient noise fields from reaching the SQUID, and to enhance spatial resolution and minimize undesirable edge effects. Thus far, the instrument has successfully detected cracks and pits through 10 layers of aluminum, with a combined thickness of 5 cm at room temperature.

  6. Research on seamless development of surgical instruments based on biological mechanisms using CAD and 3D printer.

    PubMed

    Yamamoto, Ikuo; Ota, Ren; Zhu, Rui; Lawn, Murray; Ishimatsu, Takakazu; Nagayasu, Takeshi; Yamasaki, Naoya; Takagi, Katsunori; Koji, Takehiko

    2015-01-01

    In the area of manufacturing surgical instruments, the ability to rapidly design, prototype and test surgical instruments is critical. This paper provides a simple case study of the rapid development of two bio-mechanism based surgical instruments which are ergonomic, aesthetic and were successfully designed, prototyped and conceptually tested in a very short period of time.

  7. [Development of opened instrument for generating and measuring physiological signal].

    PubMed

    Chen, Longcong; Hu, Guohu; Gao, Bin

    2004-12-01

    An opened instrument with liquid crystal display (LCD) for generating and measuring physiological signal is introduced in this paper. Based on a single-chip microcomputer. the instrument uses the technique of LCD screen to display signal wave and information, and it realizes man-machine interaction by keyboard. This instrument can produce not only defined signal in common use by utilizing important saved data and relevant arithmetic, but also user-defined signal. Therefore, it is open to produce signal. In addition, this instrument has strong extension because of its modularized design as computer, which has much function such as displaying, measuring and saving physiological signal, and many features such as low power consumption, small volume, low cost and portability. Hence this instrument is convenient for experiment teaching, clinic examining, maintaining of medical instrument.

  8. Development of an Autonomous Lidar Instrument for Use on a UAV Platform in Support of Homeland Security

    NASA Technical Reports Server (NTRS)

    McGill, Matthew; Famiglietti, Joe

    2005-01-01

    Researchers at NASA's Goddard Space Flight Center have developed an autonomous aerosol backscatter lidar instrument for use on the high-altitude ER-2 aircraft (for more information please visit http://cpl.gsfc.nasa.gov). Work is currently underway to transfer this instrument to a UAV platform such as Global Hawk. While the NASA applications are Earth science and satellite validation, there is clearly a Homeland Security application for such an instrument. One novel concept is to have a fleet of UAVs stationed around the country, each UAV having a payload including a lidar instrument. In the event of attack, the appropriate UAV(s) could be launched for purposes of, e.g., plume detection and tracking that are critical for decision support. While the existing lidar instrument is not directly capable of biological species discrimination, it is capable of plume tracking and thus can demonstrate to DHS the capabilities and utility of such instruments. Using NASA funding we will have an instrument ready to fly on Global Hawk by end of 2005. We would like to find partners, either within private industry or within DHS who would be willing to contribute aircraft access and flight hours for a demonstration flight. Longer-term partnerships to develop more advanced and more capable types of lidar instruments are also desirable. In this presentation we will detail the existing ER-2 lidar instrument and show measurement results, show the progress made on adapting to the Global Hawk platform, present concepts for DHS uses of such instruments, and openly pursue partnership opportunities.

  9. Development Status of Optical and Electromagnetic Instruments onboard JEM-GLIMS

    NASA Astrophysics Data System (ADS)

    Sato, Mitsuteru; Ushio, Tomoo; Morimoto, Takeshi; Suzuki, Makoto; Yamazaki, Atsushi; Ishida, Ryohei; Takahashi, Yukihiro; Hobara, Yasuhide; Sakamoto, Yuji; Yoshita, Kengo

    have passed the critical design review (CDR) on January and February and have started the fabrication of the proto-flight model. We will present the devel-opment status of the JEM-GLISM optical instruments and discuss the scientific outputs derived from this mission more in detail.

  10. Development an Instrument to Measure University Students' Attitude towards E-Learning

    ERIC Educational Resources Information Center

    Mehra, Vandana; Omidian, Faranak

    2012-01-01

    The study of student's attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students' attitude towards e-learning. The scale was administered to 200 University students from two countries (India…

  11. Development of an Instrument to Measure Students' Attitudes towards Piano Practice

    ERIC Educational Resources Information Center

    Umuzdas, Mehmet Serkan

    2015-01-01

    Practicing the piano is a systematic part of the instrument-learning process. It contains all development practices from the analysis of the work to the improvement of performance. Students usually practice the piano as a preparation for performing in courses, exams, or on stage and they do it individually. The mentality which emerges during the…

  12. DC servo motor positioning with anti-windup implementation using C2000 ARM-Texas Instrument

    NASA Astrophysics Data System (ADS)

    Linggarjati, Jimmy

    2017-12-01

    One of the most important topics in control system is DC Motor. At this research, a positioning control system for a DC motor is investigated. Firstly, the DC Motor will be paramaterized to get the transfer function model, in order to be simulated in Matlab, and then implemented in a C2000-ARM microcontroller from TI (Texas Instrument). With this investigation, students in control system theory will be able to understand the importance of classical control theories, in relation to the real world implementation of the position control for the DC Motor, escpecially the importance of Anti-Windup technique in real-world implementation.

  13. Development and validity of an instrumented handbike: initial results of propulsion kinetics.

    PubMed

    van Drongelen, Stefan; van den Berg, Jos; Arnet, Ursina; Veeger, Dirkjan H E J; van der Woude, Lucas H V

    2011-11-01

    To develop an instrumented handbike system to measure the forces applied to the handgrip during handbiking. A 6 degrees of freedom force sensor was built into the handgrip of an attach-unit handbike, together with two optical encoders to measure the orientation of the handgrip and crank in space. Linearity, precision, and percent error were determined for static and dynamic tests. High linearity was demonstrated for both the static and the dynamic condition (r=1.01). Precision was high under the static condition (standard deviation of 0.2N), however the precision decreased with higher loads during the dynamic condition. Percent error values were between 0.3 and 5.1%. This is the first instrumented handbike system that can register 3-dimensional forces. It can be concluded that the instrumented handbike system allows for an accurate force analysis based on forces registered at the handle bars. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    NASA Astrophysics Data System (ADS)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  15. Custom ultrasonic instrumentation for flow measurement and real-time binary gas analysis in the CERN ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Alhroob, M.; Battistin, M.; Berry, S.; Bitadze, A.; Bonneau, P.; Boyd, G.; Crespo-Lopez, O.; Degeorge, C.; Deterre, C.; Di Girolamo, B.; Doubek, M.; Favre, G.; Hallewell, G.; Katunin, S.; Lombard, D.; Madsen, A.; McMahon, S.; Nagai, K.; O'Rourke, A.; Pearson, B.; Robinson, D.; Rossi, C.; Rozanov, A.; Stanecka, E.; Strauss, M.; Vacek, V.; Vaglio, R.; Young, J.; Zwalinski, L.

    2017-01-01

    The development of custom ultrasonic instrumentation was motivated by the need for continuous real-time monitoring of possible leaks and mass flow measurement in the evaporative cooling systems of the ATLAS silicon trackers. The instruments use pairs of ultrasonic transducers transmitting sound bursts and measuring transit times in opposite directions. The gas flow rate is calculated from the difference in transit times, while the sound velocity is deduced from their average. The gas composition is then evaluated by comparison with a molar composition vs. sound velocity database, based on the direct dependence between sound velocity and component molar concentration in a gas mixture at a known temperature and pressure. The instrumentation has been developed in several geometries, with five instruments now integrated and in continuous operation within the ATLAS Detector Control System (DCS) and its finite state machine. One instrument monitors C3F8 coolant leaks into the Pixel detector N2 envelope with a molar resolution better than 2ṡ 10-5, and has indicated a level of 0.14 % when all the cooling loops of the recently re-installed Pixel detector are operational. Another instrument monitors air ingress into the C3F8 condenser of the new C3F8 thermosiphon coolant recirculator, with sub-percent precision. The recent effect of the introduction of a small quantity of N2 volume into the 9.5 m3 total volume of the thermosiphon system was clearly seen with this instrument. Custom microcontroller-based readout has been developed for the instruments, allowing readout into the ATLAS DCS via Modbus TCP/IP on Ethernet. The instrumentation has many potential applications where continuous binary gas composition is required, including in hydrocarbon and anaesthetic gas mixtures.

  16. The TOPSAR interferometric radar topographic mapping instrument

    NASA Technical Reports Server (NTRS)

    Zebker, Howard A.; Madsen, Soren N.; Martin, Jan; Alberti, Giovanni; Vetrella, Sergio; Cucci, Alessandro

    1992-01-01

    The NASA DC-8 AIRSAR instrument was augmented with a pair of C-band antennas displaced across track to form an interferometer sensitive to topographic variations of the Earth's surface. The antennas were developed by the Italian consortium Co.Ri.S.T.A., under contract to the Italian Space Agency (ASI), while the AIRSAR instrument and modifications to it supporting TOPSAR were sponsored by NASA. A new data processor was developed at JPL for producing the topographic maps, and a second processor was developed at Co.Ri.S.T.A. All the results presented below were processed at JPL. During the 1991 DC-8 flight campaign, data were acquired over several sites in the United States and Europe, and topographic maps were produced from several of these flight lines. Analysis of the results indicate that statistical errors are in the 2-3 m range for flat terrain and in the 4-5 m range for mountainous areas.

  17. Developing an Assessment Instrument to Measure Early Elementary Teachers' Mathematical Knowledge for Teaching

    ERIC Educational Resources Information Center

    Schoen, Robert C.; Bray, Wendy; Wolfe, Christopher; Tazaz, Amanda M.; Nielsen, Lynne

    2017-01-01

    This study reports on the development and field study of K-TEEM, a web-based assessment instrument designed to measure mathematical knowledge for teaching (MKT) at the early elementary level. The development process involved alignment with early elementary curriculum standards, expert review of items and scoring criteria, cognitive interviews with…

  18. Development of a canopy Solar-induced chlorophyll fluorescence measurement instrument

    NASA Astrophysics Data System (ADS)

    Sun, G.; Wang, X.; Niu, Zh; Chen, F.

    2014-02-01

    A portable solar-induced chlorophyll fluorescence detecting instrument based on Fraunhofer line principle was designed and tested. The instrument has a valid survey area of 1.3 × 1.3 meter when the height was fixed to 1.3 meter. The instrument uses sunlight as its light source. The instrument is quipped with two sets of special photoelectrical detectors with the centre wavelength at 760 nm and 771 nm respectively and bandwidth less than 1nm. Both sets of detectors are composed of an upper detector which are used for detecting incidence sunlight and a bottom detector which are used for detecting reflex light from the canopy of crop. This instrument includes photoelectric detector module, signal process module, A/D convert module, the data storage and upload module and human-machine interface module. The microprocessor calculates solar-induced fluorescence value based on the A/D values get from detectors. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's serial interface. The prototype was tested in the crop field and the results demonstrate that the instrument can measure the solar-induced chlorophyll value exactly with the correlation coefficients was 0.9 compared to the values got from Analytical Spectral Devices FieldSpec Pro spectrometer. This instrument can diagnose the plant growth status by the acquired spectral response.

  19. Expression patterns of protein C inhibitor in mouse development.

    PubMed

    Wagenaar, Gerry T M; Uhrin, Pavel; Weipoltshammer, Klara; Almeder, Marlene; Hiemstra, Pieter S; Geiger, Margarethe; Meijers, Joost C M; Schöfer, Christian

    2010-02-01

    Proteolysis of extracellular matrix is an important requirement for embryonic development and is instrumental in processes such as morphogenesis, angiogenesis, and cell migration. Efficient remodeling requires controlled spatio-temporal expression of both the proteases and their inhibitors. Protein C inhibitor (PCI) effectively blocks a range of serine proteases, and recently has been suggested to play a role in cell differentiation and angiogenesis. In this study, we mapped the expression pattern of PCI throughout mouse development using in situ hybridization and immunohistochemistry. We detected a wide-spread, yet distinct expression pattern with prominent PCI levels in skin including vibrissae, and in fore- and hindgut. Further sites of PCI expression were choroid plexus of brain ventricles, heart, skeletal muscles, urogenital tract, and cartilages. A strong and stage-dependent PCI expression was observed in the developing lung. In the pseudoglandular stage, PCI expression was present in distal branching tubules whereas proximal tubules did not express PCI. Later in development, in the saccular stage, PCI expression was restricted to distal bronchioli whereas sacculi did not express PCI. PCI expression declined in postnatal stages and was not detected in adult lungs. In general, embryonic PCI expression indicates multifunctional roles of PCI during mouse development. The expression pattern of PCI during lung development suggests its possible involvement in lung morphogenesis and angiogenesis.

  20. Patient-Reported Outcome Instruments for Surgical and Traumatic Scars: A Systematic Review of their Development, Content, and Psychometric Validation.

    PubMed

    Mundy, Lily R; Miller, H Catherine; Klassen, Anne F; Cano, Stefan J; Pusic, Andrea L

    2016-10-01

    Patient-reported outcomes (PROs) are of growing importance in research and clinical care and may be used as primary outcomes or as compliments to traditional surgical outcomes. In assessing the impact of surgical and traumatic scars, PROs are often the most meaningful. To assess outcomes from the patient perspective, rigorously developed and validated PRO instruments are essential. The authors conducted a systematic literature review to identify PRO instruments developed and/or validated for patients with surgical and/or non-burn traumatic scars. Identified instruments were assessed for content, development process, and validation under recommended guidelines for PRO instrument development. The systematic review identified 6534 articles. After review, we identified four PRO instruments meeting inclusion criteria: patient and observer scar assessment scale (POSAS), bock quality of life questionnaire for patients with keloid and hypertrophic scarring (Bock), patient scar assessment questionnaire (PSAQ), and patient-reported impact of scars measure (PRISM). Common concepts measured were symptoms and psychosocial well-being. Only PSAQ had a dedicated appearance domain. Qualitative data were used to inform content for the PSAQ and PRISM, and a modern psychometric approach (Rasch Measurement Theory) was used to develop PRISM and to test POSAS. Overall, PRISM demonstrated the most rigorous design and validation process, however, was limited by the lack of a dedicated appearance domain. PRO instruments to evaluate outcomes in scars exist but vary in terms of concepts measured and psychometric soundness. This review discusses the strengths and weaknesses of existing instruments, highlighting the need for future scar-focused PRO instrument development. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www

  1. Fitness to plead: Development and validation of a standardised assessment instrument

    PubMed Central

    Stahl, Daniel; Appiah-Kusi, Elizabeth; Brewer, Rebecca; Watts, Michael; Peay, Jill; Blackwood, Nigel

    2018-01-01

    The ability of an individual to participate in courtroom proceedings is assessed by clinicians using legal ‘fitness to plead’ criteria. Findings of ‘unfitness’ are so rare that there is considerable professional unease concerning the utility of the current subjective assessment process. As a result, mentally disordered defendants may be subjected unfairly to criminal trials. The Law Commission in England and Wales has proposed legal reform, as well as the utilisation of a defined psychiatric instrument to assist in fitness to plead assessments. Similar legal reforms are occurring in other jurisdictions. Our objective was to produce and validate a standardised assessment instrument of fitness to plead employing a filmed vignette of criminal proceedings. The instrument was developed in consultation with legal and clinical professionals, and was refined using standard item reduction methods in two initial rounds of testing (n = 212). The factorial structure, test-retest reliability and convergent validity of the resultant instrument were assessed in a further round (n = 160). As a result of this iterative process a 25-item scale was produced, with an underlying two-factor structure representing the foundational and decision-making abilities underpinning fitness to plead. The sub-scales demonstrate good internal consistency (factor 1: 0·76; factor 2: 0·65) and test-retest stability (0·7) as well as excellent convergent validity with scores of intelligence, executive function and mentalising abilities (p≤0·01 in all domains). Overall the standardised Fitness to Plead Assessment instrument has good psychometric properties. It has the potential to ensure that the significant numbers of mentally ill and cognitively impaired individuals who face trial are objectively assessed, and the courtroom process critically informed. PMID:29698396

  2. An Undergraduate Student Instrumentation Project (USIP) to Develop New Instrument Technology to Study the Auroral Ionosphere and Stratospheric Ozone Layer Using Ultralight Balloon Payloads

    NASA Astrophysics Data System (ADS)

    Gamblin, R.; Marrero, E.; Bering, E. A., III; Leffer, B.; Dunbar, B.; Ahmad, H.; Canales, D.; Bias, C.; Cao, J.; Pina, M.; Ehteshami, A.; Hermosillo, D.; Siddiqui, A.; Guala, D.

    2014-12-01

    This project is currently engaging tweleve undergraduate students in the process of developing new technology and instrumentation for use in balloon borne geospace investigations in the auroral zone. Motivation stems from advances in microelectronics and consumer electronic technology. Given the technological inovations over the past 20 years it now possible to develop new instrumentation to study the auroral ionosphere and stratospheric ozone layer using ultralight balloon payloads for less than 6lbs and $3K per payload. The UH USIP undergraduate team is currently in the process of build ten such payloads for launch using1500 gm latex weather balloons to be deployed in Houston and Fairbanks, AK as well as zero pressure balloons launched from northern Sweden. The latex balloon project will collect vertical profiles of wind speed, wind direction, temperature, electrical conductivity, ozone and odd nitrogen. This instrument payload will also profiles of pressure, electric field, and air-earth electric current. The zero pressure balloons will obtain a suite of geophysical measurements including: DC electric field, electric field and magnetic flux, optical imaging, total electron content of ionosphere via dual-channel GPS, X-ray detection, and infrared/UV spectroscopy. Students will fly payloads with different combinations of these instruments to determine which packages are successful. Data collected by these instruments will be useful in understanding the nature of electrodynamic coupling in the upper atmosphere and how the global earth system is changing. Results and best practices learned from lab tests and initial Houston test flights will be discussed.

  3. Content validity--establishing and reporting the evidence in newly developed patient-reported outcomes (PRO) instruments for medical product evaluation: ISPOR PRO good research practices task force report: part 1--eliciting concepts for a new PRO instrument.

    PubMed

    Patrick, Donald L; Burke, Laurie B; Gwaltney, Chad J; Leidy, Nancy Kline; Martin, Mona L; Molsen, Elizabeth; Ring, Lena

    2011-12-01

    The importance of content validity in developing patient reported outcomes (PRO) instruments is stressed by both the US Food and Drug Administration and the European Medicines Agency. Content validity is the extent to which an instrument measures the important aspects of concepts that developers or users purport it to assess. A PRO instrument measures the concepts most significant and relevant to a patient's condition and its treatment. For PRO instruments, items and domains as reflected in the scores of an instrument should be important to the target population and comprehensive with respect to patient concerns. Documentation of target population input in item generation, as well as evaluation of patient understanding through cognitive interviewing, can provide the evidence for content validity. Developing content for, and assessing respondent understanding of, newly developed PRO instruments for medical product evaluation will be discussed in this two-part ISPOR PRO Good Research Practices Task Force Report. Topics include the methods for generating items, documenting item development, coding of qualitative data from item generation, cognitive interviewing, and tracking item development through the various stages of research and preparing this tracking for submission to regulatory agencies. Part 1 covers elicitation of key concepts using qualitative focus groups and/or interviews to inform content and structure of a new PRO instrument. Part 2 covers the instrument development process, the assessment of patient understanding of the draft instrument using cognitive interviews and steps for instrument revision. The two parts are meant to be read together. They are intended to offer suggestions for good practices in planning, executing, and documenting qualitative studies that are used to support the content validity of PRO instruments to be used in medical product evaluation. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR

  4. THE IMPORTANCE OF INSTRUMENT MAKERS FOR THE DEVELOPMENT OF EXPERIMENTAL PSYCHOLOGY: THE CASE OF ALFRED BINET AT THE SORBONNE LABORATORY.

    PubMed

    Nicolas, Serge

    2016-07-01

    The importance of instrument firms in the development of psychology, and science in general, should not be underestimated since it would not have been possible for various leading psychologists at the turn of the twentieth century to conduct certain experiments without the assistance of instrument makers, as is often the case today. To illustrate the historical perspective introduced here, the example of Alfred Binet is taken, as he is an interesting case of a psychologist working in close collaboration with various French instrument designers of the time. The objective of this article is twofold: (1) to show the considerable activity carried out by early psychologists to finalize new laboratory instruments in order to develop their research projects; (2) to reassess the work of a major figure in French psychology through his activity as a designer of precision instruments. The development of these new instruments would certainly have been difficult without the presence in Paris of numerous precision instrument manufacturers such as Charles Verdin, Otto Lund, Henri Collin, and Lucien Korsten, on whom Binet successively called in order to develop his projects in the field of experimental psychology. © 2016 Wiley Periodicals, Inc.

  5. [Development of chlorophyll concentration nondestructive measurement instrument based on spectral analysis technology].

    PubMed

    Li, Qing-Bo; Xu, Yu-Po; Zhang, Chao-Hang; Zhang, Guang-Jun; Wu, Jin-Guang

    2009-10-01

    A portable nondestructive measuring instrument for plant chlorophyll was developed, which can perform real-time, quick and nondestructive measurement of chlorophyll. The instrument is mainly composed of four parts, including leaves clamp, driving circuit of light source, photoelectric detection and signal conditioning circuit and micro-control system. A new scheme of light source driving was proposed, which can not only achieve constant current, but also control the current by digital signal. The driving current can be changed depending on different light source and measurement situation by actual operation, which resolves the matching problem of output intensity of light source and input range of photoelectric detector. In addition, an integrative leaves clamp was designed, which simplified the optical structure, enhanced the stability of apparatus, decreased the loss of incident light and improved the signal-to-noise ratio and precision. The photoelectric detection and signal conditioning circuit achieve the conversion between optical signal and electrical signal, and make the electrical signal meet the requirement of AD conversion, and the photo detector is S1133-14 of Hamamatsu Company, with a high detection precision. The micro-control system mainly achieves control function, dealing with data, data storage and so on. As the most important component, microprocessor MSP430F149 of TI Company has many advantages, such as high processing speed, low power, high stability and so on. And it has an in-built 12 bit AD converter, so the data-acquisition circuit is simpler. MSP430F149 is suitable for portable instrument. In the calibration experiment of the instrument, the standard value was measured by chlorophyll meter SPAD-502, multiple linear calibration models were built, and the instrument performance was evaluated. The correlation coefficient between chlorophyll prediction value and standard value is 0.97, and the root mean square error of prediction is about 1

  6. Development of non-intrusive instrumentation for NASA-Ames Ballistic Range and Shock Tunnel

    NASA Technical Reports Server (NTRS)

    Strawa, A. W.; Cavolowsky, J. A.

    1990-01-01

    The use of nonintrusive instrumentation in high-enthalpy facilities offers the opportunity to collect data that has previously been difficult or impossible to obtain. Three such instruments, now under development, are described: an OH absorption system which can measure OH species concentration and temperature, a holographic interferometer for flow visualization and density measurement at low density, and a telemetry system which allows the measurement of surface quantities on model in free-flight at hypervelocity. The challenges and opportunities encountered when employing these advanced diagnostics to high-enthalpy facilities are discussed.

  7. Measuring Transactional Distance in Web-Based Learning Environments: An Initial Instrument Development

    ERIC Educational Resources Information Center

    Huang, Xiaoxia; Chandra, Aruna; DePaolo, Concetta; Cribbs, Jennifer; Simmons, Lakisha

    2015-01-01

    This study was an initial attempt to operationalise Moore's transactional distance theory by developing and validating an instrument measuring the related constructs: dialogue, structure, learner autonomy and transactional distance. Data were collected from 227 online students and analysed through an exploratory factor analysis. Results suggest…

  8. Wet chemistry instrument prototype

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A wet chemistry instrument prototype for detecting amino acids in planetary soil samples was developed. The importance of amino acids and their condensation products to the development of life forms is explained. The characteristics of the instrument and the tests which were conducted to determine the materials compatibility are described. Diagrams are provided to show the construction of the instrument. Data obtained from the performance tests are reported.

  9. The Children's Play Therapy Instrument (CPTI). Description, development, and reliability studies.

    PubMed

    Kernberg, P F; Chazan, S E; Normandin, L

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.

  10. Feedback to Managers: A Review and Comparison of Multi-Rater Instruments for Management Development. Third Edition.

    ERIC Educational Resources Information Center

    Leslie, Jean Brittain; Fleenor, John W.

    This volume describes 24 publicly available multiple-perspective management-assessment instruments that relate self-view to the views of others on multiple management and leadership domains. Each instrument also includes an assessment-for-development focus that scales managers along a continuum of psychometric properties, and "best…

  11. Functional Zoning as an Instrument for Sustainable Development of Tourism of Great Altai

    ERIC Educational Resources Information Center

    Sukhova, Maria G.; Harms, Evgenia O.; Babin, Valery G.; Zhuravleva, Olga W.; Karanin, Andrey V.

    2016-01-01

    The paper is relevant since tourism is considered as an element of sustainable development of the region, which means not only growth but also formation of a fundamentally new system of land use planning with tourism as its integrator. The purpose of the paper is development of theoretical-methodological and cartographic instruments for…

  12. 40 CFR 63.5799 - How do I calculate my facility's organic HAP emissions on a tpy basis for purposes of determining...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Calculating Organic Hap Emissions Factors for Open Molding and Centrifugal Casting § 63.5799 How do I.../casting operations, or a new facility that does not have any of the following operations: Open molding... coat is applied to an open centrifugal mold using open molding application techniques. Table 1 and the...

  13. 40 CFR 63.5799 - How do I calculate my facility's organic HAP emissions on a tpy basis for purposes of determining...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Calculating Organic Hap Emissions Factors for Open Molding and Centrifugal Casting § 63.5799 How do I.../casting operations, or a new facility that does not have any of the following operations: Open molding... coat is applied to an open centrifugal mold using open molding application techniques. Table 1 and the...

  14. WTEC panel report on European nuclear instrumentation and controls

    NASA Technical Reports Server (NTRS)

    White, James D.; Lanning, David D.; Beltracchi, Leo; Best, Fred R.; Easter, James R.; Oakes, Lester C.; Sudduth, A. L.

    1991-01-01

    Control and instrumentation systems might be called the 'brain' and 'senses' of a nuclear power plant. As such they become the key elements in the integrated operation of these plants. Recent developments in digital equipment have allowed a dramatic change in the design of these instrument and control (I&C) systems. New designs are evolving with cathode ray tube (CRT)-based control rooms, more automation, and better logical information for the human operators. As these new advanced systems are developed, various decisions must be made about the degree of automation and the human-to-machine interface. Different stages of the development of control automation and of advanced digital systems can be found in various countries. The purpose of this technology assessment is to make a comparative evaluation of the control and instrumentation systems that are being used for commercial nuclear power plants in Europe and the United States. This study is limited to pressurized water reactors (PWR's). Part of the evaluation includes comparisons with a previous similar study assessing Japanese technology.

  15. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load

    PubMed Central

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 (N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study (N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results. PMID:29201011

  16. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load.

    PubMed

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 ( N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study ( N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results.

  17. The development of an instrument to measure teachers' use of fear appeals in the GCSE classroom.

    PubMed

    Putwain, David W; Roberts, Christine M

    2009-12-01

    Previous work has suggested that teachers of General Certificate of Secondary Education classes may use fear appeals as a motivational device but these may have unwanted consequences by increasing examination-related anxiety in students. To facilitate future work in this area, an instrument was developed to measure teachers' use of fear appeals in the course of normal classroom instruction. Students in their final 2 years of compulsory schooling in England: 192 in Study 1 and 133 in Study 2. A construct validity approach was used in the development of this instrument. Study 1 reports the development and piloting of this measure. Study 2 reports refinement of this measure and relations with other constructs. A three-factor structure provided a reasonable model fit and all factors demonstrated acceptable reliability. Factors 1 and 2 described the perceived frequency of fear appeals made in relation to educational/occupational consequences and the third factor described the perceived threat of fear appeals. This instrument has demonstrated sufficient convergent and discriminant validity and reliability to be used in subsequent research, although the validation process should continue and it is hoped that the instrument will be adapted for use in other contexts.

  18. Present status of aircraft instruments

    NASA Technical Reports Server (NTRS)

    1932-01-01

    This report gives a brief description of the present state of development and of the performance characteristics of instruments included in the following group: speed instruments, altitude instruments, navigation instruments, power-plant instruments, oxygen instruments, instruments for aerial photography, fog-flying instruments, general problems, summary of instrument and research problems. The items considered under performance include sensitivity, scale errors, effects of temperature and pressure, effects of acceleration and vibration, time lag, damping, leaks, elastic defects, and friction.

  19. Optical development system lab alignment solutions for the ICESat-2 ATLAS instrument

    NASA Astrophysics Data System (ADS)

    Evans, T.

    The ATLAS Instrument for the ICESat-2 mission at NASA's Goddard Space Flight Center requires an alignment test-bed to prove out new concepts. The Optical Development System (ODS) lab was created to test prototype models of individual instrument components to simulate how they will act as a system. The main ICESat-2 instrument is the Advanced Topographic Laser Altimeter System (ATLAS). It measures ice elevation by transmitting laser pulses, and collecting the reflection in a telescope. Because the round trip time is used to calculate distance, alignment between the outgoing transmitter beam and the incoming receiver beams are critical. An automated closed loop monitoring control system is currently being tested at the prototype level to prove out implementation for the final spacecraft. To achieve an error of less than 2 micro-radians, an active deformable mirror was used to correct the lab wave front from the collimated “ ground reflection” beam. The lab includes a focal plane assembly set up, a one meter diameter collimator optic, and a 0.8 meter flight spare telescope for alignment. ATLAS prototypes and engineering models of transmitter and receiver optics and sub-systems are brought in to develop and integrate systems as well as write procedures to be used in integration and testing. By having a fully integrated system with prototypes and engineering units, lessons can be learned before flight designs are finalized.

  20. Virtual Instrument Simulator for CERES

    NASA Technical Reports Server (NTRS)

    Chapman, John J.

    1997-01-01

    A benchtop virtual instrument simulator for CERES (Clouds and the Earth's Radiant Energy System) has been built at NASA, Langley Research Center in Hampton, VA. The CERES instruments will fly on several earth orbiting platforms notably NASDA's Tropical Rainfall Measurement Mission (TRMM) and NASA's Earth Observing System (EOS) satellites. CERES measures top of the atmosphere radiative fluxes using microprocessor controlled scanning radiometers. The CERES Virtual Instrument Simulator consists of electronic circuitry identical to the flight unit's twin microprocessors and telemetry interface to the supporting spacecraft electronics and two personal computers (PC) connected to the I/O ports that control azimuth and elevation gimbals. Software consists of the unmodified TRW developed Flight Code and Ground Support Software which serves as the instrument monitor and NASA/TRW developed engineering models of the scanners. The CERES Instrument Simulator will serve as a testbed for testing of custom instrument commands intended to solve in-flight anomalies of the instruments which could arise during the CERES mission. One of the supporting computers supports the telemetry display which monitors the simulator microprocessors during the development and testing of custom instrument commands. The CERES engineering development software models have been modified to provide a virtual instrument running on a second supporting computer linked in real time to the instrument flight microprocessor control ports. The CERES Instrument Simulator will be used to verify memory uploads by the CERES Flight Operations TEAM at NASA. Plots of the virtual scanner models match the actual instrument scan plots. A high speed logic analyzer has been used to track the performance of the flight microprocessor. The concept of using an identical but non-flight qualified microprocessor and electronics ensemble linked to a virtual instrument with identical system software affords a relatively inexpensive

  1. The development and validation of the speech quality instrument.

    PubMed

    Chen, Stephanie Y; Griffin, Brianna M; Mancuso, Dean; Shiau, Stephanie; DiMattia, Michelle; Cellum, Ilana; Harvey Boyd, Kelly; Prevoteau, Charlotte; Kohlberg, Gavriel D; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-12-08

    Although speech perception tests are available to evaluate hearing, there is no standardized validated tool to quantify speech quality. The objective of this study is to develop a validated tool to measure quality of speech heard. Prospective instrument validation study of 35 normal hearing adults recruited at a tertiary referral center. Participants listened to 44 speech clips of male/female voices reciting the Rainbow Passage. Speech clips included original and manipulated excerpts capturing goal qualities such as mechanical and garbled. Listeners rated clips on a 10-point visual analog scale (VAS) of 18 characteristics (e.g. cartoonish, garbled). Skewed distribution analysis identified mean ratings in the upper and lower 2-point limits of the VAS (ratings of 8-10, 0-2, respectively); items with inconsistent responses were eliminated. The test was pruned to a final instrument of nine speech clips that clearly define qualities of interest: speech-like, male/female, cartoonish, echo-y, garbled, tinny, mechanical, rough, breathy, soothing, hoarse, like, pleasant, natural. Mean ratings were highest for original female clips (8.8) and lowest for not-speech manipulation (2.1). Factor analysis identified two subsets of characteristics: internal consistency demonstrated Cronbach's alpha of 0.95 and 0.82 per subset. Test-retest reliability of total scores was high, with an intraclass correlation coefficient of 0.76. The Speech Quality Instrument (SQI) is a concise, valid tool for assessing speech quality as an indicator for hearing performance. SQI may be a valuable outcome measure for cochlear implant recipients who, despite achieving excellent speech perception, often experience poor speech quality. 2b. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  2. AIM - Agile Instrumented Monitoring for Improving User Experience of Participation in HealthIT Development.

    PubMed

    Pitkänen, Janne; Nieminen, Marko

    2017-01-01

    Participation of healthcare professionals in information technology development has emerged as an important challenge. As end-users, the professionals are willing to participate in the development activities, but their experiences on the current methods of participation remain mostly negative. There is lack of applicable methods for meeting the needs of agile development approach and scaling up to the largest implementation projects, while maintaining the interest of the professional users to participate in development activities and keeping up their ability to continue working in a productive manner. In this paper, we describe the Agile Instrumented Monitoring as a methodology, based on the methods of instrumented usability evaluation, for improving user experience in HealthIT development. The contribution of the proposed methodology is analyzed in relation to activities of whole iteration cycle and chosen usability evaluation methods, while the user experience of participation is addressed regarding healthcare professionals. Prospective weak and strong market tests for AIM are discussed in the conclusions for future work.

  3. Development and Psychometric Examination of the Inclusive Teaching Strategies in Nursing Education Instrument.

    PubMed

    Levey, Janet A

    2017-08-01

    Nurse educators might be unknowingly excluding learners secondary to teaching practices. Universal design for instruction (UDI) prepares and delivers accessible content and learning environments for diverse learners; however, it is not well known in nursing education. The aim of the study was to examine the psychometric properties of the Inclusive Teaching Strategies in Nursing Education (ITSinNE) 55-item instrument. Confirmatory factor analysis was performed on a sample of 311 educators in prelicensure programs. The ITSinNE scales had good to adequate estimates of reliability. The exogenous model fit the sample and model-implied covariance matrix; however, the endogenous model was not a good fit. Further instrument development is required. Measuring factors influencing nurse educators' willingness to adopt UDI will enable intervention research to enhance professional development fostering content and environmental access for all learners.

  4. Development and psychometric testing of the nursing student mentors' competence instrument (MCI): A cross-sectional study.

    PubMed

    Tuomikoski, Anna-Maria; Ruotsalainen, Heidi; Mikkonen, Kristina; Miettunen, Jouko; Kääriäinen, Maria

    2018-06-05

    Mentors require competence at a diverse array of skills to mentor students during clinical practice. According to the latest evidence, competence at mentoring includes: knowledge, skills and attributes of individual students' learning objectives, core elements of nursing, learning processes, a reciprocal and trustful relationship, feedback, evaluation, cooperation with stakeholders, and the mentor's personal qualities. The purpose of the study was to test psychometric properties of a mentor's competence instrument developed to self-evaluate mentors' competence at mentoring nursing students in clinical practice. A cross-sectional, descriptive, explorative study design was used. Data were collected from mentors at five university hospitals in Finland in 2016. A total of 576 mentors participated in this study. The instrument was developed through systematic review, experts' evaluations, and pilot versions of the instrument tested in previous studies. The construct validity and reliability of the instrument were tested using exploratory factor analysis (EFA) with promax rotation and Cronbach's alpha. A 10-factor model showed that the instrument has acceptable construct validity. Cronbach's alpha values for the subscales observed ranged from 0.76 to 0.90. The instrument exhibited acceptable psychometric properties, thereby proving itself a valuable tool for evaluating mentors' competence at mentoring students. Further assessments of its reliability, validity and generality for measuring mentor's competence for mentoring students in different contexts and cultures are recommended. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Development and Psychometric Evaluation of the Instrument: Attitudes Towards Organ Donor Advocacy Scale (ATODAS)

    PubMed Central

    Flodén, Anne; Lennerling, Annette; Fridh, Isabell; Rizell, Magnus; Forsberg, Anna

    2011-01-01

    The consequences of advocacy in nursing are critical when caring for a potential organ donor. No specific instrument has been available to measure attitudes toward organ donor advocacy. The aim of this study was to develop and psychometrically evaluate an instrument for measuring intensive and critical care (ICU) nurses’ attitudes toward organ donor advocacy. The study was conducted in two stages: instrument development and instrument evaluation and refinement. A questionnaire was developed (Attitude Toward Organ Donor Advocacy Scale (ATODAS)), which was sent to half of all nurses working in ICUs (general-, neuro-, thoracic- or paediatric-) in Sweden (n=1180). The final response rate was 42.5% (n=502). In order to explore validity and reliability, the expected scale dimensionality of the questionnaire was examined both by explorative principal component analysis (with oblique, varimax rotation) and by confirmatory multi-trait analysis. The confirmatory factor analysis indicated that the ATODAS could best be explained by five factors; Attitudes toward championing organ donation at a structural hospital level; Attitudes toward championing organ donation at a political and research level; Attitudes toward actively and personally safeguarding the will and wishes of the potential organ donor, Attitudes toward safeguarding the potential donor’s will and wishes by a professional approach and Attitudes toward safeguarding the will and wishes of the relatives. This initial testing indicated that the ATODAS has good psychometric properties and can be used in future research to explore if interventions may influence attitudes and behaviors related to organ donor advocacy. PMID:22046210

  6. Nursing Intensive-Care Satisfaction Scale [NICSS]: Development and validation of a patient-centred instrument.

    PubMed

    Romero-García, Marta; de la Cueva-Ariza, Laura; Benito-Aracil, Llucia; Lluch-Canut, Teresa; Trujols-Albet, Joan; Martínez-Momblan, Maria Antonia; Juvé-Udina, Maria-Eulàlia; Delgado-Hito, Pilar

    2018-06-01

    The aim of this study was to develop and validate the Nursing Intensive-Care Satisfaction Scale to measures satisfaction with nursing care from the critical care patient's perspective. Instruments that measure satisfaction with nursing cares have been designed and validated without taking the patient's perspective into consideration. Despite the benefits and advances in measuring satisfaction with nursing care, none instrument is specifically designed to assess satisfaction in intensive care units. Instrument development. The population were all discharged patients (January 2013 - January 2015) from three Intensive Care Units of a third level hospital (N = 200). All assessment instruments were given to discharged patients and 48 hours later, to analyse the temporal stability, only the questionnaire was given again. The validation process of the scale included the analysis of internal consistency, temporal stability; validity of construct through a confirmatory factor analysis; and criterion validity. Reliability was 0.95. The intraclass correlation coefficient for the total scale was 0.83 indicating a good temporal stability. Construct validity showed an acceptable fit and factorial structure with four factors, in accordance with the theoretical model, being Consequences factor the best correlated with other factors. Criterion validity, presented a correlation between low and high (range: 0.42-0.68). The scale has been designed and validated incorporating the perspective of critical care patients. Thanks to its reliability and validity, this questionnaire can be used both in research and in clinical practice. The scale offers a possibility to assess and develop interventions to improve patient satisfaction with nursing care. © 2018 John Wiley & Sons Ltd.

  7. The Development of a Physical Education Teachers' Physical Activity Self-Efficacy Instrument.

    ERIC Educational Resources Information Center

    Martin, Jeffrey J.; Kulinna, Pamela Hodges

    2003-01-01

    Developed a valid, reliable physical education teachers' physical activity self-efficacy scale for teaching classes in which students were engaged in high levels of physical activity. Results offer preliminary support for the psychometric properties of this instrument, which can help understand physical education teachers' efficacy in overcoming…

  8. Towards an Operational Definition of Effective Co-Teaching: Instrument Development, Validity, and Reliability

    ERIC Educational Resources Information Center

    La Monte, Michelle Evonne

    2012-01-01

    This study focused on developing a valid and reliable instrument that can not only identify successful co-teaching, but also the professional development needs of co-teachers and their administrators in public schools. Two general questions about the quality of co-teaching were addressed in this study: (a) How well did descriptors within each of…

  9. Perspective on the National Aero-Space Plane Program instrumentation development

    NASA Technical Reports Server (NTRS)

    Bogue, Rodney K.; Erbland, Peter

    1993-01-01

    A review of the requirement for, and development of, advanced measurement technology for the National Aerospace Plane program is presented. The objective is to discuss the technical need and the program commitment required to ensure that adequate and timely measurement capabilities are provided for ground and flight testing in the NASP program. The scope of the measurement problem is presented, the measurement process is described, how instrumentation technology development has been affected by NASP program evolution is examined, the national effort to define measurement requirements and assess the adequacy of current technology to support the NASP program is discussed, and the measurement requirements are summarized. The unique features of the NASP program that complicate the understanding of requirements and the development of viable solutions are illustrated.

  10. Climate of Respect Evaluation in ICUs: Development of an Instrument (ICU-CORE).

    PubMed

    Beach, Mary Catherine; Topazian, Rachel; Chan, Kitty S; Sugarman, Jeremy; Geller, Gail

    2018-06-01

    To develop a valid, reliable measure that reflected the environment of respectfulness within the ICU setting. We developed a preliminary survey instrument based on conceptual domains of respect identified through prior qualitative analyses of ICU patient, family member, and clinician perspectives. The initial instrument consisted of 21 items. After five cognitive interviews and 16 pilot surveys, we revised the instrument to include 23 items. We used standard psychometric methods to analyze the instrument. Eight ICUs serving adult patients affiliated with a large university health system. ICU clinicians. None. Based on 249 responses, we identified three factors and created subscales: General Respect, Respectful Behaviors, and Disrespectful Behaviors. The General Respect subscale had seven items (α = 0.932) and reflected how often patients in the ICU are treated with respect, in a dignified manner, as an individual, equally to all other patients, on the "same level" as the ICU team, as a person, and as you yourself would want to be treated. The Respectful Behaviors subscale had 10 items (α = 0.926) and reflected how often the ICU team responds to patient and/or family anxiety, makes an effort to get to know the patient and family as people, listens carefully, explains things thoroughly, gives the opportunity to provide input into care, protects patient modesty, greets when entering room, and talks to sedated patients. The subscale measuring disrespect has four items (α = 0.702) and reflects how often the ICU team dismisses family concerns, talks down to patients and families, speaks disrespectfully behind their backs, and gets frustrated with patients and families. We created a reliable set of scales to measure the climate of respectfulness in intensive care settings. These measures can be used for ongoing quality improvement that aim to enhance the experience of ICU patients and their families.

  11. Instrument Remote Control via the Astronomical Instrument Markup Language

    NASA Technical Reports Server (NTRS)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  12. Instrumentation Development for Large Scale Hypersonic Inflatable Aerodynamic Decelerator Characterization

    NASA Technical Reports Server (NTRS)

    Swanson, Gregory T.; Cassell, Alan M.

    2011-01-01

    Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology is currently being considered for multiple atmospheric entry applications as the limitations of traditional entry vehicles have been reached. The Inflatable Re-entry Vehicle Experiment (IRVE) has successfully demonstrated this technology as a viable candidate with a 3.0 m diameter vehicle sub-orbital flight. To further this technology, large scale HIADs (6.0 8.5 m) must be developed and tested. To characterize the performance of large scale HIAD technology new instrumentation concepts must be developed to accommodate the flexible nature inflatable aeroshell. Many of the concepts that are under consideration for the HIAD FY12 subsonic wind tunnel test series are discussed below.

  13. Reliability and validity of the C-BiLLT: a new instrument to assess comprehension of spoken language in young children with cerebral palsy and complex communication needs.

    PubMed

    Geytenbeek, Joke J; Mokkink, Lidwine B; Knol, Dirk L; Vermeulen, R Jeroen; Oostrom, Kim J

    2014-09-01

    In clinical practice, a variety of diagnostic tests are available to assess a child's comprehension of spoken language. However, none of these tests have been designed specifically for use with children who have severe motor impairments and who experience severe difficulty when using speech to communicate. This article describes the process of investigating the reliability and validity of the Computer-Based Instrument for Low Motor Language Testing (C-BiLLT), which was specifically developed to assess spoken Dutch language comprehension in children with cerebral palsy and complex communication needs. The study included 806 children with typical development, and 87 nonspeaking children with cerebral palsy and complex communication needs, and was designed to provide information on the psychometric qualities of the C-BiLLT. The potential utility of the C-BiLLT as a measure of spoken Dutch language comprehension abilities for children with cerebral palsy and complex communication needs is discussed.

  14. Development of an Instrument to Assess Prospective Elementary Teacher Self-Efficacy Beliefs about Equitable Science Teaching and Learning (SEBEST)

    NASA Astrophysics Data System (ADS)

    Ritter, Jennifer M.; Boone, William J.; Rubba, Peter A.

    2001-06-01

    This paper presents an overview of the procedures used to develop and validate an instrument to measure the self-efficacy beliefs of prospective elementary teachers about equitable science teaching and learning. The instrument, titled the SEBEST, was based on the work of Ashton and Webb (1986a, 1986b) and Bandura (1977, 1986). It was modeled after the Science Teaching Efficacy Belief Instrument (STEBI) (Riggs, 1988) and the Science Teaching Efficacy Belief Instrument for Prospective Teachers (STEBI-B) (Enochs & Riggs, 1990). Based on the standardized development procedures used and associated evidence, the SEBEST appears to be a content and construct valid instrument, with high internal reliability qualities. "Most probable response" plots are introduced and used to bring meaning to SEBEST raw scores.

  15. A Parsimonious Instrument for Predicting Students' Intent to Pursue a Sales Career: Scale Development and Validation

    ERIC Educational Resources Information Center

    Peltier, James W.; Cummins, Shannon; Pomirleanu, Nadia; Cross, James; Simon, Rob

    2014-01-01

    Students' desire and intention to pursue a career in sales continue to lag behind industry demand for sales professionals. This article develops and validates a reliable and parsimonious scale for measuring and predicting student intention to pursue a selling career. The instrument advances previous scales in three ways. The instrument is…

  16. Development of an Instrument for Assessing Senior High School Students' Preferred and Perceived Laboratory Classroom Environment

    ERIC Educational Resources Information Center

    Hsiao, Chien-Hua; Wu, Ying-Tien; Lin, Chung-Yen; Wong, Terrence William; Fu, Hsieh-Hai; Yeh, Ting-Kuang; Chang, Chung-Yen

    2014-01-01

    This study aimed to develop an instrument, named the inquiry-based laboratory classroom environment instrument (ILEI), for assessing senior high-school science students' preferred and perceived laboratory environment. A total of 262 second-year students, from a senior-high school in Taiwan, were recruited for this study. Four stages were included…

  17. Development and Validation of an Instrument to Measure Indonesian Pre-Service Teachers' Conceptions of Statistics

    ERIC Educational Resources Information Center

    Idris, Khairiani; Yang, Kai-Lin

    2017-01-01

    This article reports the results of a mixed-methods approach to develop and validate an instrument to measure Indonesian pre-service teachers' conceptions of statistics. First, a phenomenographic study involving a sample of 44 participants uncovered six categories of conceptions of statistics. Second, an instrument of conceptions of statistics was…

  18. Development of Young Adults' Fine Motor Skills when Learning to Play Percussion Instruments

    ERIC Educational Resources Information Center

    Gzibovskis, Talis; Marnauza, Mara

    2012-01-01

    When playing percussion instruments, the main activity is done with the help of a motion or motor skills; to perform it, developed fine motor skills are necessary: the speed and precision of fingers, hands and palms. The aim of the research was to study and test the development of young adults' fine motor skills while learning to play percussion…

  19. An integrated development facility for the calibration of low-energy charged particle flight instrumentation

    NASA Technical Reports Server (NTRS)

    Biddle, A. P.; Reynolds, J. M.

    1985-01-01

    A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

  20. An Empirical Development of an Instrument To Assess Mathematics Anxiety and Apprehension.

    ERIC Educational Resources Information Center

    Ikegulu, T. Nelson

    The development and psychometric properties of the Mathematics Anxiety-Apprehension Survey (MAAS), a measure of instructional and/or classroom mathematics phobia are discussed. This instrument was designed to assess levels of mathematics anxiety and apprehension in students with varying levels of education and socio-demographic factors. The highly…

  1. Development of a video-simulation instrument for assessing cognition in older adults.

    PubMed

    Ip, Edward H; Barnard, Ryan; Marshall, Sarah A; Lu, Lingyi; Sink, Kaycee; Wilson, Valerie; Chamberlain, Dana; Rapp, Stephen R

    2017-12-06

    Commonly used methods to assess cognition, such as direct observation, self-report, or neuropsychological testing, have significant limitations. Therefore, a novel tablet computer-based video simulation was created with the goal of being valid, reliable, and easy to administer. The design and implementation of the SIMBAC (Simulation-Based Assessment of Cognition) instrument is described in detail, as well as informatics "lessons learned" during development. The software emulates 5 common instrumental activities of daily living (IADLs) and scores participants' performance. The modules were chosen by a panel of geriatricians based on relevance to daily functioning and ability to be modeled electronically, and included facial recognition, pairing faces with the correct names, filling a pillbox, using an automated teller machine (ATM), and automatic renewal of a prescription using a telephone. Software development included three phases 1) a period of initial design and testing (alpha version), 2) pilot study with 10 cognitively normal and 10 cognitively impaired adults over the age of 60 (beta version), and 3) larger validation study with 162 older adults of mixed cognitive status (release version). Results of the pilot study are discussed in the context of refining the instrument; full results of the validation study are reported in a separate article. In both studies, SIMBAC reliably differentiated controls from persons with cognitive impairment, and performance was highly correlated with Mini Mental Status Examination (MMSE) score. Several informatics challenges emerged during software development, which are broadly relevant to the design and use of electronic assessment tools. Solutions to these issues, such as protection of subject privacy and safeguarding against data loss, are discussed in depth. Collection of fine-grained data (highly detailed information such as time spent reading directions and the number of taps on screen) is also considered. SIMBAC provides

  2. Developing an instrument for assessing students' concepts of the nature of technology

    NASA Astrophysics Data System (ADS)

    Liou, Pey-Yan

    2015-05-01

    Background:The nature of technology has been rarely discussed despite the fact that technology plays an essential role in modern society. It is important to discuss students' concepts of the nature of technology, and further to advance their technological literacy and adaptation to modern society. There is a need to assess high school students' concepts of the nature of technology. Purpose:This study aims to engage in discourse on students' concepts of the nature of technology based on a proposed theoretical framework. Moreover, another goal is to develop an instrument for measuring students' concepts of the nature of technology. Sample:Four hundred and fifty-five high school students' perceptions of technology were qualitatively analyzed. Furthermore, 530 students' responses to a newly developed questionnaire were quantitatively analyzed in the final test. Design and method:First, content analysis was utilized to discuss and categorize students' statements regarding technology and its related issues. The Student Concepts of the Nature of Technology Questionnaire was developed based on the proposed theoretical framework and was supported by the students' qualitative data. Finally, exploratory factor analysis and reliability analysis were applied to determine the structure of the items and the internal consistency of each scale. Results:Through a process of instrument development, the Student Concepts of the Nature of Technology Questionnaire was shown to be a valid and reliable tool for measuring students' concepts of the nature of technology. This newly developed questionnaire is composed of 29 items in six scales, namely 'technology as artifacts,' 'technology as an innovation change,' 'the current role of technology in society,' 'technology as a double-edged sword,' 'technology as a science-based form,' and 'history of technology.' Conclusions:The Student Concepts of the Nature of Technology Questionnaire has been confirmed as a reasonably valid and reliable

  3. The sense of security in care--Relatives' Evaluation instrument: its development and presentation.

    PubMed

    Krevers, Barbro; Milberg, Anna

    2015-03-01

    Relatives' sense of security in their family members' palliative home care is important, and a valid and reliable instrument is needed to measure this. The aim of this article is to report the development, structure, and psychometric properties of a new instrument, the Sense of Security in Care--Relatives' Evaluation (SEC-R), in palliative home care. Instrument development was based on a previous study and review of the literature; 213 relatives (55% women) of patients in palliative home care were recruited (response rate 73%) and participated in a structured interview based on a questionnaire. Principal component analysis (PCA) was used to identify subscales. The construction was tested in correlation with other scales and questions representing concepts expected to be related to sense of security in care. The PCA resulted in three subscales, namely care interaction, mastery and patient situation, which had an explained variance of 53%. Internal consistency of the subscales ranged from 0.76 to 0.78. The final instrument comprises 17 items. The scales were associated with the quality-of-care process and the relatives' situation, perceived health, quality of life, stress, general sense of security, and general sense of security in care. The SEC-R provides a three-component assessment of palliative home care settings using valid and reliable scales associated with other concepts. The SEC-R is a manageable means of assessment that may contribute to quality-of-care measures and to further research on relatives' sense of security in care. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  4. Development and testing of an instrument to measure protective nursing advocacy.

    PubMed

    Hanks, Robert G

    2010-03-01

    Patient advocacy is an important aspect of nursing care, yet there are few instruments to measure this essential function. This study was conducted to develop, determine the psychometric properties, and support validity of the Protective Nursing Advocacy Scale (PNAS), which measures nursing advocacy beliefs and actions from a protective perspective. The study used a descriptive correlational design with a systematically selected sample of 419 medical-surgical registered nurses. Analysis of the 43-item instrument was conducted using principal components analysis with promax rotation, which resulted in the items loading onto four components. The four subscales have sufficient internal consistency, as did the overall PNAS. Satisfactory evidence of construct, content, and convergent validity were determined. Implications for nursing practice include using the PNAS in conjunction with an educational program to enhance advocacy skills, which may help to improve patient outcomes.

  5. Chromatographic instrumentation in space: past, present and future developments for exobiological studies

    NASA Astrophysics Data System (ADS)

    Raulin, F.; Sternberg, R.; Coscia, D.; Vidal-Madjar, C.; Millot, M.-C.; Sébille, B.; Israel, G.

    1999-01-01

    Several planetary exploration missions have already used chromatographic techniques to search for organic compounds, including complex organics, in extraterrestrial environments. So far, only gas chromatography (GC) has been used. In two cases (Viking and Cassini-Huygens), a Py-GC-MS instrument, coupling GC with a pyrolyzer and a mass spectrometer, has been flown. Powerful miniaturized Py-GC-MS instrumentation, with high resolution multi-GC columns and time-of-flight or Ion Trap mass spectrometers are under development, in the frame of the preparation of the Rosetta mission. There is now a strong need for new chromatographic instrumentation in space, in particular to perform detailed molecular analyses of complex non-volatile organics, including macromolecular compounds. Liquid Chromatography (LC), in particular High Performance Liquid Chromatography (HPLC) Supercritical Fluid Chromatography (SFC) or Chemical-Derivatization Gas Chromatography (CDGC) could provide a very efficient mean of analyzing a wide variety of exobiologically important compounds. LC or CDGC have never been used in space yet, but feasibility studies on their application in planetary mission are needed.

  6. The development and testing of a qualitative instrument designed to assess critical thinking

    NASA Astrophysics Data System (ADS)

    Clauson, Cynthia Louisa

    This study examined a qualitative approach to assess critical thinking. An instrument was developed that incorporates an assessment process based on Dewey's (1933) concepts of self-reflection and critical thinking as problem solving. The study was designed to pilot test the critical thinking assessment process with writing samples collected from a heterogeneous group of students. The pilot test included two phases. Phase 1 was designed to determine the validity and inter-rater reliability of the instrument using two experts in critical thinking, problem solving, and literacy development. Validity of the instrument was addressed by requesting both experts to respond to ten questions in an interview. The inter-rater reliability was assessed by analyzing the consistency of the two experts' scorings of the 20 writing samples to each other, as well as to my scoring of the same 20 writing samples. Statistical analyses included the Spearman Rho and the Kuder-Richardson (Formula 20). Phase 2 was designed to determine the validity and reliability of the critical thinking assessment process with seven science teachers. Validity was addressed by requesting the teachers to respond to ten questions in a survey and interview. Inter-rater reliability was addressed by comparing the seven teachers' scoring of five writing samples with my scoring of the same five writing samples. Again, the Spearman Rho and the Kuder-Richardson (Formula 20) were used to determine the inter-rater reliability. The validity results suggest that the instrument is helpful as a guide for instruction and provides a systematic method to teach and assess critical thinking while problem solving with students in the classroom. The reliability results show the critical thinking assessment instrument to possess fairly high reliability when used by the experts, but weak reliability when used by classroom teachers. A major conclusion was drawn that teachers, as well as students, would need to receive instruction

  7. AUDIT and AUDIT-C as screening instruments for alcohol problem use in adolescents.

    PubMed

    Liskola, Joni; Haravuori, Henna; Lindberg, Nina; Niemelä, Solja; Karlsson, Linnea; Kiviruusu, Olli; Marttunen, Mauri

    2018-07-01

    The Alcohol Use Disorders Identification Test (AUDIT) is commonly used in adults to screen for harmful alcohol consumption but few studies exist on its use among adolescents. Our aim was to validate the AUDIT and its derivative consumption questionnaire (AUDIT-C) as screening instruments for the detection of problem use of alcohol in adolescents. 621 adolescents (age-range, 12-19 years) were drawn from clinical and population samples who completed the AUDIT questionnaire. Psychiatric diagnoses were assessed using K-SADS-PL. A rating based on the K-SADS-PL was used to assess alcohol use habits, alcohol use disorders, screening and symptom criteria questions. Screening performance of the AUDIT and AUDIT-C sum scores and Receiver Operating Characteristic (ROC) curves were calculated. The diagnostic odds ratios (dOR) were calculated to express the overall discrimination between cut-offs. Comparisons of ROC between the AUDIT and AUDIT-C pairs indicated a slightly better test performance by AUDIT for the whole sample and in a proportion of the subsamples. Optimal cut-off value for the AUDIT was ≥5 (sensitivity 0.931, specificity 0.772, dOR 45.22; 95% CI: 24.72-83.57) for detecting alcohol problem use. The corresponding optimal cut-off value for the AUDIT-C was ≥3 in detecting alcohol problem use (sensitivity 0.952, specificity 0.663, dOR 39.31; 95% CI: 19.46-78.97). Agreement between the AUDIT and AUDIT-C using these cut-off scores was high at 91.9%. Our results for the cut-off scores for the early detection of alcohol problem use in adolescents are ≥5 for AUDIT, and ≥3 for AUDIT-C. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Instrumental support to facilitate hepatitis C treatment adherence: working around shortfalls in shared-care.

    PubMed

    Sublette, Victoria A; Hopwood, Max; George, Jacob; Smith, Sian K; Perry, Kathryn Nicholson; McCaffery, Kirsten; Douglas, Mark W

    2015-01-01

    Adherence to treatment for hepatitis C virus (HCV) infection is associated with the successful eradication of infection. However, patients often have difficulty adhering to HCV treatment because of factors such as the psychiatric side effects of regimens and social disadvantage. Commonly, health professionals including specialist physicians, nurses, social workers and psychologists work together under a multidisciplinary model of shared-care to support patients' adherence to HCV treatment. In some HCV treatment clinics, shared-care is not always available, or only partially implemented and this has implications for patient adherence. To explore the facilitators of adherence, an interview-based study was conducted in 2012 with a purposive sample of Australian physicians and nurses (N = 20). The findings reveal that when comprehensive shared-care was limited or unavailable, physicians and nurses filled in the gaps by assuming roles outside of their expertise to help patients adhere to HCV treatment. Physicians and nurses applied instrumental support strategies based on psychosocial interventions, namely patient advocacy, pragmatic problem-solving, treatment engagement and emotional support. These strategies were provided by dedicated physicians and nurses to address shortfalls in multidisciplinary shared-care. Although these interventions were reported to assist adherence, there is an increased risk of complications when physicians and nurses move beyond the bounds of their disciplinary training, for example, to assess and manage patients' psychiatric side effects or advocate on their behalf for social services. Future research should measure the effectiveness of instrumental support strategies on HCV treatment adherence, and explore the costs associated with physicians and nurses providing instrumental support in the absence of comprehensive multidisciplinary shared-care.

  9. What Are They Thinking? The Development and Use of an Instrument that Identifies Common Science Misconceptions

    ERIC Educational Resources Information Center

    Stein, Mary; Barman, Charles R.; Larrabee, Timothy

    2007-01-01

    This article describes the rationale for, and development of, an online instrument that helps identify commonly held science misconceptions. Science Beliefs is a 47-item instrument that targets topics in chemistry, physics, biology, earth science, and astronomy. It utilizes a true or false, along with a written-explanation, format. The true or…

  10. Development and Validation of a Quality-of-Life Instrument for Infantile Hemangiomas.

    PubMed

    Chamlin, Sarah L; Mancini, Anthony J; Lai, Jin-Shei; Beaumont, Jennifer L; Cella, David; Adams, Denise; Drolet, Beth; Baselga, Eulalia; Frieden, Ilona J; Garzon, Maria; Holland, Kristin; Horii, Kimberly A; Lucky, Anne W; McCuaig, Catherine; Metry, Denise; Morel, Kimberly D; Newell, Brandon D; Nopper, Amy J; Powell, Julie; Siegel, Dawn; Haggstrom, Anita N

    2015-06-01

    Infantile hemangiomas (IH) are common tumors for which there is no validated disease-specific instrument to measure the quality of life in infants and their parents/caregivers during the critical first months of life. This study prospectively developed and validated a quality-of-life instrument for patients with IH and their parents/caregivers and correlated demographic and clinical features to the effects on the quality of life. A total of 220 parents/caregivers completed the 35-item Infantile Hemangioma Quality-of-Life (IH-QoL) instrument and provided demographic information. The dimensionality of the items was evaluated using factor analysis, with results suggesting four factors: child physical symptoms, child social interactions, parent emotional functioning, and parent psychosocial functioning. Each factor fit the Rasch measurement model with acceptable fit index (mean square <1.4) and demonstrated excellent internal consistency, with alpha ranging from 0.76 to 0.88. The final instrument consists of four scales with a total of 29 items. Content validity was verified by analyzing parents' responses to an open-ended question. Test-retest reliability at a 48-hour interval was supported by a total IH-QoL intraclass correlation coefficient of 0.84. Certain clinical characteristics of hemangioma, including those located on the head and neck, in the proliferative stage, and requiring treatment, are associated with a greater impact on QoL.

  11. The clinical learning environment and supervision by staff nurses: developing the instrument.

    PubMed

    Saarikoski, Mikko; Leino-Kilpi, Helena

    2002-03-01

    The aims of this study were (1) to describe students' perceptions of the clinical learning environment and clinical supervision and (2) to develop an evaluation scale by using the empirical results of this study. The data were collected using the Clinical Learning Environment and Supervision instrument (CLES). The instrument was based on the literature review of earlier studies. The derived instrument was tested empirically in a study involving nurse students (N=416) from four nursing colleges in Finland. The results demonstrated that the method of supervision, the number of separate supervision sessions and the psychological content of supervisory contact within a positive ward atmosphere are the most important variables in the students' clinical learning. The results also suggest that ward managers can create the conditions of a positive ward culture and a positive attitude towards students and their learning needs. The construct validity of the instrument was analysed by using exploratory factor analysis. The analysis indicated that the most important factor in the students' clinical learning is the supervisory relationship. The two most important factors constituting a 'good' clinical learning environment are the management style of the ward manager and the premises of nursing on the ward. The results of the factor analysis support the theoretical construction of the clinical learning environment modelled by earlier empirical studies.

  12. From theory to 'measurement' in complex interventions: methodological lessons from the development of an e-health normalisation instrument.

    PubMed

    Finch, Tracy L; Mair, Frances S; O'Donnell, Catherine; Murray, Elizabeth; May, Carl R

    2012-05-17

    Although empirical and theoretical understanding of processes of implementation in health care is advancing, translation of theory into structured measures that capture the complex interplay between interventions, individuals and context remain limited. This paper aimed to (1) describe the process and outcome of a project to develop a theory-based instrument for measuring implementation processes relating to e-health interventions; and (2) identify key issues and methodological challenges for advancing work in this field. A 30-item instrument (Technology Adoption Readiness Scale (TARS)) for measuring normalisation processes in the context of e-health service interventions was developed on the basis on Normalization Process Theory (NPT). NPT focuses on how new practices become routinely embedded within social contexts. The instrument was pre-tested in two health care settings in which e-health (electronic facilitation of healthcare decision-making and practice) was used by health care professionals. The developed instrument was pre-tested in two professional samples (N=46; N=231). Ratings of items representing normalisation 'processes' were significantly related to staff members' perceptions of whether or not e-health had become 'routine'. Key methodological challenges are discussed in relation to: translating multi-component theoretical constructs into simple questions; developing and choosing appropriate outcome measures; conducting multiple-stakeholder assessments; instrument and question framing; and more general issues for instrument development in practice contexts. To develop theory-derived measures of implementation process for progressing research in this field, four key recommendations are made relating to (1) greater attention to underlying theoretical assumptions and extent of translation work required; (2) the need for appropriate but flexible approaches to outcomes measurement; (3) representation of multiple perspectives and collaborative nature of

  13. The Development of an Instrument to Measure the Project Competences of College Students in Online Project-Based Learning

    ERIC Educational Resources Information Center

    Lin, Chien-Liang

    2018-01-01

    This study sought to develop a self-report instrument to be used in the assessment of the project competences of college students engaged in online project-based learning. Three scales of the KIPSSE instrument developed for this study, namely, the knowledge integration, project skills, and self-efficacy scales, were based on related theories and…

  14. Perceived experiences of atheist discrimination: Instrument development and evaluation.

    PubMed

    Brewster, Melanie E; Hammer, Joseph; Sawyer, Jacob S; Eklund, Austin; Palamar, Joseph

    2016-10-01

    The present 2 studies describe the development and initial psychometric evaluation of a new instrument, the Measure of Atheist Discrimination Experiences (MADE), which may be used to examine the minority stress experiences of atheist people. Items were created from prior literature, revised by a panel of expert researchers, and assessed psychometrically. In Study 1 (N = 1,341 atheist-identified people), an exploratory factor analysis with 665 participants suggested the presence of 5 related dimensions of perceived discrimination. However, bifactor modeling via confirmatory factor analysis and model-based reliability estimates with data from the remaining 676 participants affirmed the presence of a strong "general" factor of discrimination and mixed to poor support for substantive subdimensions. In Study 2 (N = 1,057 atheist-identified people), another confirmatory factor analysis and model-based reliability estimates strongly supported the bifactor model from Study 1 (i.e., 1 strong "general" discrimination factor) and poor support for subdimensions. Across both studies, the MADE general factor score demonstrated evidence of good reliability (i.e., Cronbach's alphas of .94 and .95; omega hierarchical coefficients of .90 and .92), convergent validity (i.e., with stigma consciousness, β = .56; with awareness of public devaluation, β = .37), and preliminary evidence for concurrent validity (i.e., with loneliness β = .18; with psychological distress β = .27). Reliability and validity evidence for the MADE subscale scores was not sufficient to warrant future use of the subscales. Limitations and implications for future research and clinical work with atheist individuals are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Measuring Development of Adolescent and Young Adult Cancer Patients: An Integrative Review of Available Instruments.

    PubMed

    Bell, Cynthia J; Bell, Ryan A; Zebrack, Brad; Kato, Ikuko; Morse, Alyssa; Borinstein, Scott C

    2018-06-01

    Adolescents and young adults (AYAs) 15-39 years old face unique challenges during cancer treatment as developmental and social needs are often disrupted to achieve cure. Developmentally appropriate supportive care for AYAs across the cancer trajectory is needed. The purpose of this review is to identify and describe instruments that measure AYA development across physical, psychological, and social domains, commenting on the instruments' psychometric properties and usefulness in clinical practice and research. A computerized literature search published in English from 1950 to January of 2017 was conducted utilizing the following databases: Mental Measurements Yearbook (MMY), Health and Psychosocial Instruments, PubMed, Cumulative Index to Nursing and Allied Health Literature (CINAHL), PsycINFO, and Google Scholar. The following instruments were identified and described: the Child Health and Illness Profile-Adolescent Edition (CHIP-AE); the Course of Life Questionnaire; the Developmental Task Questionnaire (DTQ); the Impact of Cancer scale for childhood survivors and AYAs (IOC-CS and IOC-AYA); the McCleery Scale of Adolescent Development (MSAD); and the Minneapolis-Manchester Quality of Life Adolescent and Young Adult Form (MMQL-AF and MMQL-YA). Among currently available instruments, the IOC-AYA and MMQL-AF were relevant to AYAs undergoing or completing cancer therapy. However, validation for the IOC-AYA occurred in cancer survivors off treatment so further psychometric evaluation is needed in AYAs currently undergoing cancer treatment. Furthermore, the MMQL-AF has been validated for use during active cancer treatment, but is limited to adolescents 13-20 years. Further research may be needed to create or refine instruments measuring the developmental impact in AYAs, particularly emerging adults undergoing active cancer treatment.

  16. Applying the Mixed Methods Instrument Development and Construct Validation Process: the Transformative Experience Questionnaire

    ERIC Educational Resources Information Center

    Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.

    2018-01-01

    Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…

  17. Developing the System for Observing Behavioral Ecology for Youth in Schools Instrument

    ERIC Educational Resources Information Center

    Lorenz, Kent A.; van der Mars, Hans; Kulinna, Pamela H.; Ainsworth, Barbara E.; Hovell, Melbourne F.

    2017-01-01

    Background: Behavioral support may be effective in increasing physical activity (PA) in school settings. However, there are no data collection systems to concurrently record PA and behavioral support. This paper describes the development and validation of the System for Observing Behavioral Ecology for Youth in Schools (SOBEYS)--an instrument used…

  18. Launching GUPPI: the Green Bank Ultimate Pulsar Processing Instrument

    NASA Astrophysics Data System (ADS)

    DuPlain, Ron; Ransom, Scott; Demorest, Paul; Brandt, Patrick; Ford, John; Shelton, Amy L.

    2008-08-01

    The National Radio Astronomy Observatory (NRAO) is launching the Green Bank Ultimate Pulsar Processing Instrument (GUPPI), a prototype flexible digital signal processor designed for pulsar observations with the Robert C. Byrd Green Bank Telescope (GBT). GUPPI uses field programmable gate array (FPGA) hardware and design tools developed by the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California, Berkeley. The NRAO has been concurrently developing GUPPI software and hardware using minimal software resources. The software handles instrument monitor and control, data acquisition, and hardware interfacing. GUPPI is currently an expert-only spectrometer, but supports future integration with the full GBT production system. The NRAO was able to take advantage of the unique flexibility of the CASPER FPGA hardware platform, develop hardware and software in parallel, and build a suite of software tools for monitoring, controlling, and acquiring data with a new instrument over a short timeline of just a few months. The NRAO interacts regularly with CASPER and its users, and GUPPI stands as an example of what reconfigurable computing and open-source development can do for radio astronomy. GUPPI is modular for portability, and the NRAO provides the results of development as an open-source resource.

  19. Development and Validation of an Instrument to Measure Students' Motivation and Self-Regulation in Science Learning

    NASA Astrophysics Data System (ADS)

    Velayutham, Sunitadevi; Aldridge, Jill; Fraser, Barry

    2011-10-01

    Students' motivational beliefs and self-regulatory practices have been identified as instrumental in influencing the engagement of students in the learning process. An important aim of science education is to empower students by nurturing the belief that they can succeed in science learning and to cultivate the adaptive learning strategies required to help to bring about that success. This article reports the development and validation of an instrument to measure salient factors related to the motivation and self-regulation of students in lower secondary science classrooms. The development of the instrument involved identifying key determinants of students' motivation and self-regulation in science learning based on theoretical and research underpinnings. Once the instrument was developed, a pilot study involving 52 students from two Grade 8 science classes was undertaken. Quantitative data were collected from 1,360 students in 78 classes across Grades 8, 9, and 10, in addition to in-depth qualitative information gathered from 10 experienced science teachers and 12 Grade 8 students. Analyses of the data suggest that the survey has strong construct validity when used with lower secondary students. This survey could be practically valuable as a tool for gathering information that may guide classroom teachers in refocusing their teaching practices and help to evaluate the effectiveness of intervention programmes.

  20. The beam combiners of Gravity VLTI instrument: concept, development, and performance in laboratory

    NASA Astrophysics Data System (ADS)

    Jocou, L.; Perraut, K.; Moulin, T.; Magnard, Y.; Labeye, P.; Lapras, V.; Nolot, A.; Perrin, G.; Eisenhauer, F.; Holmes, C.; Amorim, A.; Brandner, W.; Straubmeier, C.

    2014-07-01

    Gravity is one of the second-generation instruments of the Very Large Telescope Interferometer that operates in the near infrared range and that is designed for precision narrow-angle astrometry and interferometric imaging. With its infrared wavefront sensors, pupil stabilization, fringe tracker, and metrology, the instrument is tailored to provide a high sensitivity, imaging with 4-millisecond resolution, and astrometry with a 10μarcsec precision. It will probe physics close to the event horizon of the Galactic Centre black hole, and allow to study mass accretion and jets in young stellar objects and active galactic nuclei, planet formation in circumstellar discs, or detect and measure the masses of black holes in massive star clusters throughout the Milky Way. As the instrument required an outstanding level of precision and stability, integrated optics has been chosen to collect and combine the four VLTI beams in the K band. A dedicated integrated optics chip glued to a fiber array has been developed. Technology breakthroughs have been mandatory to fulfill all the specifications. This paper is focused on the interferometric beam combination system of Gravity. Once the combiner concept described, the paper details the developments that have been led, the integration and the performance of the assemblies.

  1. Regression of an atlantoaxial rheumatoid pannus following posterior instrumented fusion.

    PubMed

    Bydon, Mohamad; Macki, Mohamed; Qadi, Mohamud; De la Garza-Ramos, Rafael; Kosztowski, Thomas A; Sciubba, Daniel M; Wolinsky, Jean-Paul; Witham, Timothy F; Gokaslan, Ziya L; Bydon, Ali

    2015-10-01

    Rheumatoid patients may develop a retrodental lesion (atlantoaxial rheumatoid pannus) that may cause cervical instability and/or neurological compromise. The objective is to characterize clinical and radiographic outcomes after posterior instrumented fusion for atlantoaxial rheumatoid pannus. We retrospectively reviewed all patients who underwent posterior fusions for an atlantoaxial rheumatoid pannus at a single institution. Both preoperative and postoperative imaging was available for all patients. Anterior or circumferential operations, non-atlantoaxial panni, or prior C1-C2 operations were excluded. Primary outcome measures included Nurick score, Ranawat score (neurologic status in patients with rheumatoid arthritis), pannus regression, and reoperation. Pannus volume was determined with axial and sagittal views on both preoperative and postoperative radiological images. Thirty patients surgically managed for an atlantoaxial rheumatoid pannus were followed for a mean of 24.43 months. Nine patients underwent posterior instrumented fusion alone, while 21 patients underwent posterior decompression and instrumented fusion. Following a posterior instrumented fusion in all 30 patients, the pannus statistically significantly regressed by 44.44%, from a mean volume of 1.26cm(3) to 0.70cm(3) (p<0.001), over 8.02 months. The Nurick score significantly improved from 2.40 to 0.60 (p<0.001), but the marginal improvement of 0.20 in the Ranawat score did not reach significance (p=0.312). Six patients (20%) required reoperations over a mean of 13.18 months. Reoperations were indicated for C1 instrumentation failure in four patients and pseudoarthrosis in two patients. Following posterior instrumented fusion, the pannus radiographically regressed by 44.44% over a mean of 8.02 months, and patients clinically improved per the Nurick score. The Ranawat score did not improve, and 20% of patients required reoperation over a mean of 13.18 months. The annualized reoperation rate was

  2. Development of the Potassium-Argon Laser Experiment (KArLE) Instrument for In Situ Geochronology

    NASA Technical Reports Server (NTRS)

    Cohen, Barbara A.; Li, Z.-H.; Miller, J. S.; Brinckerhoff, W. B.; Clegg, S. M.; Mahaffy, P. R.; Swindle, T. D.; Wiens, R. C.

    2012-01-01

    Absolute dating of planetary samples is an essential tool to establish the chronology of geological events, including crystallization history, magmatic evolution, and alteration. Traditionally, geochronology has only been accomplishable on samples from dedicated sample return missions or meteorites. The capability for in situ geochronology is highly desired, because it will allow one-way planetary missions to perform dating of large numbers of samples. The success of an in situ geochronology package will not only yield data on absolute ages, but can also complement sample return missions by identifying the most interesting rocks to cache and/or return to Earth. In situ dating instruments have been proposed, but none have yet reached TRL 6 because the required high-resolution isotopic measurements are very challenging. Our team is now addressing this challenge by developing the Potassium (K) - Argon Laser Experiment (KArLE) under the NASA Planetary Instrument Definition and Development Program (PIDDP), building on previous work to develop a K-Ar in situ instrument [1]. KArLE uses a combination of several flight-proven components that enable accurate K-Ar isochron dating of planetary rocks. KArLE will ablate a rock sample, determine the K in the plasma state using laser-induced breakdown spectroscopy (LIBS), measure the liberated Ar using quadrupole mass spectrometry (QMS), and relate the two by the volume of the ablated pit using an optical method such as a vertical scanning interferometer (VSI). Our preliminary work indicates that the KArLE instrument will be capable of determining the age of several kinds of planetary samples to +/-100 Myr, sufficient to address a wide range of geochronology problems in planetary science.

  3. 14 CFR 27.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 27.1303... navigation instruments. The following are the required flight and navigation instruments: (a) An airspeed indicator. (b) An altimeter. (c) A magnetic direction indicator. ...

  4. 14 CFR 27.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flight and navigation instruments. 27.1303... navigation instruments. The following are the required flight and navigation instruments: (a) An airspeed indicator. (b) An altimeter. (c) A magnetic direction indicator. ...

  5. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    PubMed

    Harris, Laura Florence; Awoonor-Williams, John Koku; Gerdts, Caitlin; Gil Urbano, Laura; González Vélez, Ana Cristina; Halpern, Jodi; Prata, Ndola; Baffoe, Peter

    2016-01-01

    Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision. A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana. The model posits three domains of conscientious objection that form the basis for the survey instrument: 1) beliefs about abortion and conscientious objection; 2) actions related to conscientious objection and abortion; and 3) self-identification as a conscientious objector. The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  6. Development and validation of a survey instrument for assessing prescribers' perception of computerized drug-drug interaction alerts.

    PubMed

    Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D

    2011-12-01

    To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.

  7. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    PubMed

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  8. Development and Validation of a Novel Generic Health-related Quality of Life Instrument With 20 Items (HINT-20)

    PubMed Central

    2017-01-01

    Objectives Few attempts have been made to develop a generic health-related quality of life (HRQoL) instrument and to examine its validity and reliability in Korea. We aimed to do this in our present study. Methods After a literature review of existing generic HRQoL instruments, a focus group discussion, in-depth interviews, and expert consultations, we selected 30 tentative items for a new HRQoL measure. These items were evaluated by assessing their ceiling effects, difficulty, and redundancy in the first survey. To validate the HRQoL instrument that was developed, known-groups validity and convergent/discriminant validity were evaluated and its test-retest reliability was examined in the second survey. Results Of the 30 items originally assessed for the HRQoL instrument, four were excluded due to high ceiling effects and six were removed due to redundancy. We ultimately developed a HRQoL instrument with a reduced number of 20 items, known as the Health-related Quality of Life Instrument with 20 items (HINT-20), incorporating physical, mental, social, and positive health dimensions. The results of the HINT-20 for known-groups validity were poorer in women, the elderly, and those with a low income. For convergent/discriminant validity, the correlation coefficients of items (except vitality) in the physical health dimension with the physical component summary of the Short Form 36 version 2 (SF-36v2) were generally higher than the correlations of those items with the mental component summary of the SF-36v2, and vice versa. Regarding test-retest reliability, the intraclass correlation coefficient of the total HINT-20 score was 0.813 (p<0.001). Conclusions A novel generic HRQoL instrument, the HINT-20, was developed for the Korean general population and showed acceptable validity and reliability. PMID:28173686

  9. Development and Validation of a Novel Generic Health-related Quality of Life Instrument With 20 Items (HINT-20).

    PubMed

    Jo, Min-Woo; Lee, Hyeon-Jeong; Kim, Soo Young; Kim, Seon-Ha; Chang, Hyejung; Ahn, Jeonghoon; Ock, Minsu

    2017-01-01

    Few attempts have been made to develop a generic health-related quality of life (HRQoL) instrument and to examine its validity and reliability in Korea. We aimed to do this in our present study. After a literature review of existing generic HRQoL instruments, a focus group discussion, in-depth interviews, and expert consultations, we selected 30 tentative items for a new HRQoL measure. These items were evaluated by assessing their ceiling effects, difficulty, and redundancy in the first survey. To validate the HRQoL instrument that was developed, known-groups validity and convergent/discriminant validity were evaluated and its test-retest reliability was examined in the second survey. Of the 30 items originally assessed for the HRQoL instrument, four were excluded due to high ceiling effects and six were removed due to redundancy. We ultimately developed a HRQoL instrument with a reduced number of 20 items, known as the Health-related Quality of Life Instrument with 20 items (HINT-20), incorporating physical, mental, social, and positive health dimensions. The results of the HINT-20 for known-groups validity were poorer in women, the elderly, and those with a low income. For convergent/discriminant validity, the correlation coefficients of items (except vitality) in the physical health dimension with the physical component summary of the Short Form 36 version 2 (SF-36v2) were generally higher than the correlations of those items with the mental component summary of the SF-36v2, and vice versa. Regarding test-retest reliability, the intraclass correlation coefficient of the total HINT-20 score was 0.813 (p<0.001). A novel generic HRQoL instrument, the HINT-20, was developed for the Korean general population and showed acceptable validity and reliability.

  10. Development in the SONNE Instrument, a Solar Neutron Spectrometer for Solar Orbiter and Solar Sentinels

    NASA Astrophysics Data System (ADS)

    Ryan, J. M.; Bravar, U.; Macri, J. R.; McConnell, M. L.; Woolf, R.; Moser, M.; Flueckiger, E.; Pirard, B.; MacKinnon, A.; Mallik, P.; Bruillard, P.

    2007-12-01

    We report on the technical development of SONNE (Solar Neutron Experiment), a solar neutron spectrometer intended for use on the ESA Solar Orbiter and/or the NASA Solar Sentinels Missions. Development has taken place on three fronts, (1) simulations of a flight instrument, including the spacecraft radiation environment, (2) calibrating a prototype instrument in a monoenergetic neutron beam and (3) mechanical and electrical design of a deep space mission instrument. SONNE will be sensitive to fast neutrons up to 20 MeV, using double scatter imaging techniques to dramatically reduce background. Preliminary beam measurement analysis, conducted just before this abstract, supports advertised design goals in terms of sensitivity and energy resolution, meaning that time stamping neutron emission from the Sun will be possible. Combined with gamma ray measurements, new insight into particle acceleration will emerge when deployed on an inner heliospheric mission. Progress will be reported on simulations and physical design as well as calibrations.

  11. Development of Mirror Modules for the ART-XC Instrument aboard the Spectrum-Roentgen-Gamma Mission

    NASA Technical Reports Server (NTRS)

    Gubarev, M; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.; Atkins, C.; hide

    2013-01-01

    The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission. Four of those modules are being fabricated under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) An additional three flight modules and one spare for the ART-XC Instrument are produced under a Cooperative Agreement between NASA and IKI. The instrument will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Each module consists of 28 nested thin Ni/Co shells giving an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of the first four modules is scheduled for November 2013, while the remaining three modules will be delivered to IKI in January 2014. We present a status of the ART x-ray module development at MSFC.

  12. Development of mirror modules for the ART-XC instrument aboard the Spectrum-Roentgen-Gamma mission

    NASA Astrophysics Data System (ADS)

    Gubarev, M.; Ramsey, B.; O'Dell, S. L.; Elsner, R.; Kilaru, K.; McCracken, J.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.; Atkins, C.; Zavlin, V.

    2013-09-01

    The Marshall Space Flight Center (MSFC) is developing x-ray mirror modules for the ART-XC instrument on board the Spectrum-Roentgen Gamma Mission. Four of those modules are being fabricated under a Reimbursable Agreement between NASA and the Russian Space Research Institute (IKI.) An additional three flight modules and one spare for the ART-XC Instrument are produced under a Cooperative Agreement between NASA and IKI. The instrument will consist of seven co-aligned x-ray mirror modules with seven corresponding CdTe focal plane detectors. Each module consists of 28 nested thin Ni/Co shells giving an effective area of 65 cm2 at 8 keV, response out to 30 keV, and an angular resolution of 45 arcsec or better HPD. Delivery of the first four modules is scheduled for November 2013, while the remaining three modules will be delivered to IKI in January 2014. We present a status of the ART x-ray module development at MSFC.

  13. Using a Systematic Approach to Develop a Chemistry Course Introducing Students to Instrumental Analysis

    ERIC Educational Resources Information Center

    Shen, Hao-Yu; Shen, Bo; Hardacre, Christopher

    2013-01-01

    A systematic approach to develop the teaching of instrumental analytical chemistry is discussed, as well as a conceptual framework for organizing and executing lectures and a laboratory course. Three main components are used in this course: theoretical knowledge developed in the classroom, simulations via a virtual laboratory, and practical…

  14. Development and Validation of Nature of Science Instrument for Elementary School Students

    ERIC Educational Resources Information Center

    Hacieminoglu, Esme; Yilmaz-Tüzün, Özgül; Ertepinar, Hamide

    2014-01-01

    The purposes of this study were to develop and validate an instrument for assessing elementary students' nature of science (NOS) views and to explain the elementary school students' NOS views, in terms of varying grade levels and gender. The sample included 782 students enrolled in sixth, seventh, and eighth grades. Exploratory factor analysis…

  15. Preliminary Development of an Attrition Risk Assessment Instrument for Secondary Agricultural Educators

    ERIC Educational Resources Information Center

    Greenhaw, Laura L.; Brashears, M. Todd; Burris, Scott; Meyers, Courtney; Morrison, Carley C.

    2017-01-01

    Secondary agricultural education has consistently faced a shortage of teachers for the past several decades. Because there are not enough newly qualified teachers certified annually to fill all the vacancies, attrition must be addressed. The purpose of this research was to develop and pilot test an attrition risk assessment instrument. Items were…

  16. The Development of the Network Examination for Student Socialization (NEXSS) Observational Instrument

    ERIC Educational Resources Information Center

    Rhoades, Jesse Lee; Hastmann, Tanis Joy

    2014-01-01

    The complexity of learning has plagued the educational establishment for decades. Recently, ideas of complexity theory and complex adaptive systems have made headway in how we think of institutions of learning. This study developed and tested an instrument for the modeling of underlying social structures, as an element of complexity, within the…

  17. Developing an Observation Instrument to Support Authentic Independent Reading Time during School in a Data-Driven World

    ERIC Educational Resources Information Center

    Williams, Lunetta M.; Hall, Katrina W.; Hedrick, Wanda B.; Lamkin, Marcia; Abendroth, Jennifer

    2013-01-01

    The purpose of the present study was to develop an instrument to measure reading during in-school independent reading (ISIR). Procedures to establish validity and reliability of the instrument included videotaping and observing students during ISIR, gathering feedback from literacy experts, establishing interrater reliability, crosschecking…

  18. Peak exposures in aluminium potrooms: instrument development and field calibration.

    PubMed

    Carter, Stephanie R; Seixas, Noah S; Thompson, Mary Lou; Yost, Michael G

    2004-11-01

    Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas" instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.

  19. Design and Development of the Aircraft Instrument Comprehension Program.

    ERIC Educational Resources Information Center

    Higgins, Norman C.

    The Aircraft Instrument Comprehension (AIC) Program is a self-instructional program designed to teach undergraduate student pilots to read instruments that indicate the position of the aircraft in flight, based on sequential instructional stages of information, prompted practice, and unprompted practice. The program includes a 36-item multiple…

  20. Development and validation of an objective instrument to measure surgical performance at tonsillectomy.

    PubMed

    Roberson, David W; Kentala, Erna; Forbes, Peter

    2005-12-01

    The goals of this project were 1) to develop and validate an objective instrument to measure surgical performance at tonsillectomy, 2) to assess its interobserver and interobservation reliability and construct validity, and 3) to select those items with best reliability and most independent information to design a simplified form suitable for routine use in otolaryngology surgical evaluation. Prospective, observational data collection for an educational quality improvement project. The evaluation instrument was based on previous instruments developed in general surgery with input from attending otolaryngologic surgeons and experts in medical education. It was pilot tested and subjected to iterative improvements. After the instrument was finalized, a total of 55 tonsillectomies were observed and scored during academic year 2002 to 2003: 45 cases by residents at different points during their rotation, 5 by fellows, and 5 by faculty. Results were assessed for interobserver reliability, interobservation reliability, and construct validity. Factor analysis was used to identify items with independent information. Interobserver and interobservation reliability was high. On technical items, faculty substantially outperformed fellows, who in turn outperformed residents (P < .0001 for both comparisons). On the "global" scale (overall assessment), residents improved an average of 1 full point (on a 5 point scale) during a 3 month rotation (P = .01). In the subscale of "patient care," results were less clear cut: fellows outperformed residents, who in turn outperformed faculty, but only the fellows to faculty comparison was statistically significant (P = .04), and residents did not clearly improve over time (P = .36). Factor analysis demonstrated that technical items and patient care items factor separately and thus represent separate skill domains in surgery. It is possible to objectively measure surgical skill at tonsillectomy with high reliability and good construct

  1. 14 CFR 23.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... navigation instruments. (c) A magnetic direction indicator. ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 23.1303... General § 23.1303 Flight and navigation instruments. Link to an amendment published at 76 FR 75760...

  2. The Children's Play Therapy Instrument (CPTI): Description, Development, and Reliability Studies

    PubMed Central

    Kernberg, Paulina F.; Chazan, Saralea E.; Normandin, Lina

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.(The Journal of Psychotherapy Practice and Research 1998; 7:196–207) PMID:9631341

  3. Mechanical evaluation of articulating instruments and cross-handed manipulation in laparoendoscopic single-site surgery.

    PubMed

    Xu, An An; Zhu, Jiang Fan; Xie, Xiaofeng; Su, Yuantao

    2014-08-01

    Laparoendoscopic single-site surgery (LESS) is limited by loss of triangulation and internal instruments conflict. To overcome these difficulties, some concepts have been introduced, namely, articulating instruments and cross-handed manipulation, which causes the right hand to control the left instrument tip and vice versa. The aim of this study was to compare task performance with different approaches based on a mechanical evaluation platform. A LESS mechanical evaluation platform was set up to investigate the performance of 2 tasks (suture pass-through rings and clip-cut) with 3 different settings: uncrossed manipulation with straight instruments (group A, the control group), uncrossed manipulation with articulating instruments (group B), and cross-handed manipulation with articulating instruments (group C). The operation time and average load required for accomplishment of the standard tasks were measured. Group A presented significantly better time scores than group B, and group C consumed the longest time to accomplish the 2 tasks (P < .05). Comparing of average load required to perform the suture pass-through rings task, it differed significantly between dominant and nondominant hand in all groups (P < .01) and was less in group A and group B than group C in dominant hand (P < .01), while it was almost the same in all groups in the nondominant hand. In terms of average load requirement to accomplish clip-cut task, it was almost equal not only between group A and B but also between dominant and nondominant hand while the increase reached statistical significance when comparing group C with other groups (P < .05). Compared with conventional devices and maneuvering techniques, articulating instruments and cross-handed manipulation are associated with longer operation time and higher workload. Instruments with better maneuverability should be developed in the future for LESS. © The Author(s) 2013.

  4. Development of a Photo-fragmentation Laser Induced Fluorescence Instrument for the Measurement of Nitrous Acid

    NASA Astrophysics Data System (ADS)

    Boustead, G.; Blitz, M. A.; Heard, D. E.; Ingham, T.; Stone, D. J.; Whalley, L.

    2017-12-01

    The hydroxyl radical (OH) is the primary oxidant in the atmosphere with its concentration determining the lifetime of many species and its reaction with volatile organic compounds (VOCs) leading to the production of secondary organic aerosols (SOA) and tropospheric ozone. Nitrous acid (HONO) is an important source of OH as it builds up overnight and is photolysed to form OH in the morning. HONO is also present during the day, with several hundred pptv observed in urban environments. Atmospheric models currently under predict the concentration of HONO observed during the day, indicating a missing source. Heterogeneous reactions on ground and aerosol surfaces are now recognised as potentially important HONO sources. To identify and quantify some of these missing heterogeneous sources, a photo-fragmentation laser induced fluorescence (PF-LIF) instrument has been developed to provide a fast and sensitive measurement of HONO. The PF-LIF instrument detects the OH fragment at 308 nm after the photolysis of HONO at 355 nm. This instrument is coupled to an aerosol flow tube and can be used to measure HONO production from aerosols under illuminated conditions. We will present an overview of the instrument and its development as well as preliminary results including the production of HONO from illuminated TiO2 aerosols.

  5. Pancreatitis Quality of Life Instrument: A Psychometric Evaluation.

    PubMed

    Wassef, Wahid; DeWitt, John; McGreevy, Kathleen; Wilcox, Mel; Whitcomb, David; Yadav, Dhiraj; Amann, Stephen; Mishra, Girish; Alkaade, Samer; Romagnuolo, Joseph; Stevens, Tyler; Vargo, John; Gardner, Timothy; Singh, Vikesh; Park, Walter; Hartigan, Celia; Barton, Bruce; Bova, Carol

    2016-08-01

    Chronic pancreatitis is a significant medical problem that impacts a large number of patients worldwide. In 2014, we developed a disease-specific instrument for the evaluation of quality of life in this group of patients: pancreatitis quality of life instrument (PANQOLI). The goal of this study was to evaluate its psychometric properties: its reliability and its construct validity. This is a cross-sectional multi-center study that involved 12 pancreatic disease centers. Patients who met the inclusion/exclusion criteria for chronic pancreatitis were invited to participate. Those who accepted were asked to complete seven questionnaires/instruments. Only patients who completed the PANQOLI were included in the study. Its reliability and its construct validity were tested. A total of 159 patients completed the PANQOLI and were included in the study. They had a mean age of 49.03, 49% were male, and 84% were Caucasian. Six of the 24 items on the scale were removed because of lack of inter-item correlation, redundancy, or lack of correlation to quality of life issues. The final 18-item scale had excellent reliability (Cronbach's alpha coefficient: 0.914) and excellent construct validity with good correlation to generic quality of life instruments (SF-12 and EORTC QLQ-C30/QLQ-PAN26) and lack of correlation to non-quality of life instruments (MAST and DAST). Through exploratory factor analysis, the PANQOLI was found to consist of four subscales: emotional function scale, role function scale, physical function scale, and "self-worth" scale. PANQOLI is the first disease-specific instrument to be developed and validated for the evaluation of quality of life in chronic pancreatitis patients. It has a unique subscale for "self-worth" that differentiates it from other generic instruments. Studies are currently under way to evaluate its use in other populations not included in this study.

  6. The Early Development Instrument: Translating School Readiness Assessment into Community Actions and Policy Planning

    ERIC Educational Resources Information Center

    Guhn, Martin; Janus, Magdalena; Hertzman, Clyde

    2007-01-01

    This invited special issue of "Early Education and Development" presents research related to the Early Development Instrument (EDI; Janus & Offord, 2007), a community tool to assess children's school readiness at a population level. In this editorial introduction, we first sketch out recent trends in school readiness research that call for a…

  7. Developing an Assessment Instrument to Measure Early Elementary Teachers' Mathematical Knowledge for Teaching

    ERIC Educational Resources Information Center

    Schoen, Robert C.; Bray, Wendy; Wolfe, Christopher; Tazaz, Amanda M.; Nielsen, Lynne

    2017-01-01

    This study reports on the development and field study of K-TEEM, a web-based assessment instrument designed to measure mathematical knowledge for teaching (MKT) at the early elementary level. The development process involved alignment with early elementary curriculum standards, expert review of items and scoring criteria, cognitive interviews with…

  8. Building the BIKE: Development and Testing of the Biotechnology Instrument for Knowledge Elicitation (BIKE)

    NASA Astrophysics Data System (ADS)

    Witzig, Stephen B.; Rebello, Carina M.; Siegel, Marcelle A.; Freyermuth, Sharyn K.; Izci, Kemal; McClure, Bruce

    2014-10-01

    Identifying students' conceptual scientific understanding is difficult if the appropriate tools are not available for educators. Concept inventories have become a popular tool to assess student understanding; however, traditionally, they are multiple choice tests. International science education standard documents advocate that assessments should be reform based, contain diverse question types, and should align with instructional approaches. To date, no instrument of this type targeting student conceptions in biotechnology has been developed. We report here the development, testing, and validation of a 35-item Biotechnology Instrument for Knowledge Elicitation (BIKE) that includes a mix of question types. The BIKE was designed to elicit student thinking and a variety of conceptual understandings, as opposed to testing closed-ended responses. The design phase contained nine steps including a literature search for content, student interviews, a pilot test, as well as expert review. Data from 175 students over two semesters, including 16 student interviews and six expert reviewers (professors from six different institutions), were used to validate the instrument. Cronbach's alpha on the pre/posttest was 0.664 and 0.668, respectively, indicating the BIKE has internal consistency. Cohen's kappa for inter-rater reliability among the 6,525 total items was 0.684 indicating substantial agreement among scorers. Item analysis demonstrated that the items were challenging, there was discrimination among the individual items, and there was alignment with research-based design principles for construct validity. This study provides a reliable and valid conceptual understanding instrument in the understudied area of biotechnology.

  9. Development of performance test instrument in the experiment of law of conservation mass using self and peer assessment’s technique

    NASA Astrophysics Data System (ADS)

    Siswaningsih, W.; Nahadi; Firmansyah, D. R.

    2018-05-01

    The purpose of this research is to develop the instrument of performance assessment of law of mass conservation using self and peer assessment technique that meet valid and reliable criteria. The instrument components consist of task and rubric. The method used is development and validation.Value of the instrument reliability obtained from twice observations that are at four and six students every group with three same observers. Cronbach alpha value for four and six students every group consecutively are 0.94 and 0.76, indicating that value shows that the instrument is reliable. Optimum amount of the students that can be observed are four students. The implementation of the instrument to limited group of students showed that All of the students give positive responses to the instrument used with the interpretation of questionnaire scores >90% that categorized as good.

  10. 14 CFR 25.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... indicator (nonstabilized magnetic compass). (b) The following flight and navigation instruments must be... (gyroscopically stabilized, magnetic or nonmagnetic). (c) The following flight and navigation instruments are... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 25.1303...

  11. 14 CFR 25.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... indicator (nonstabilized magnetic compass). (b) The following flight and navigation instruments must be... (gyroscopically stabilized, magnetic or nonmagnetic). (c) The following flight and navigation instruments are... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flight and navigation instruments. 25.1303...

  12. Development of a computer-adaptive physical function instrument for Social Security Administration disability determination.

    PubMed

    Ni, Pengsheng; McDonough, Christine M; Jette, Alan M; Bogusz, Kara; Marfeo, Elizabeth E; Rasch, Elizabeth K; Brandt, Diane E; Meterko, Mark; Haley, Stephen M; Chan, Leighton

    2013-09-01

    To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors identified in prior factor analyses, (2) assess the fit of the items within each scale, (3) develop separate computer-adaptive testing (CAT) instruments for each scale, and (4) conduct initial psychometric testing. Cross-sectional data collection; IRT analyses; CAT simulation. Telephone and Internet survey. Two samples: SSA claimants (n=1017) and adults from the U.S. general population (n=999). None. Model fit statistics, correlation, and reliability coefficients. IRT analyses resulted in 5 unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. On comparing the simulated CATs with the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared with those of a sample of U.S. adults. The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    PubMed

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  14. Development of an Instrument for the Assessment of Parenting Attitudes. An Affective Evaluation Study: Parent Involvement Report Number 1.

    ERIC Educational Resources Information Center

    Conrad, Rowan W.; Pollack, Robert M.

    Development of the Child Raising Opinion Questionnaire to assess the attitudes of Mountain-Plains parents toward children was undertaken due to the inadequacy of other instruments in this area. Important factors in the development of the instrument were the parenting attitude of acceptance/rejection, the ability to perceive the child's…

  15. NASA Aerosciences Perspective on Proposed De-Scope of Ares I-X Development Flight Instrumentation

    NASA Technical Reports Server (NTRS)

    Schuster, David M.

    2009-01-01

    This position paper is written as a result of a number of emails and a presentation that have recently been circulated concerning the potential reduction of Development Flight Instrumentation (DFI) to be included on the Ares I-X flight test vehicle. A reduction in instrumentation has been proposed presumably to reduce project costs and relieve project schedule pressures. This proposal has generated a significant amount of discussion on both sides of the issue, primarily from those within the project. The intention here is to provide a perspective on this issue from outside the mainline project.

  16. Rural parents' perceived stigma of seeking mental health services for their children: development and evaluation of a new instrument.

    PubMed

    Williams, Stacey L; Polaha, Jodi

    2014-09-01

    The purpose of our research was to examine the validity of score interpretations of an instrument developed to measure parents' perceptions of stigma about seeking mental health services for their children. The validity of the score interpretations of the instrument was tested in 2 studies. Study 1 employed confirmatory factor analysis (CFA), using a split half approach, and construct and criterion validity on data from the entire sample of parents in rural Appalachia whose children were experiencing psychosocial concerns (N = 347), while Study 2 employed CFA, construct and criterion validity, and predictive validity of the scores on data from a general sample of parents in rural Appalachia (N = 184). Results of exploratory and confirmatory factor analyses revealed support for a 2-factor model of parents' perceived stigma, which represented both self and public forms of stigma associated with seeking mental health services for their children, and correlated with existing measures of stigma and other psychosocial variables. Further, the new self and public stigma scale significantly predicted parents' willingness to seek services for children. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  17. The Development and Validation of an Instrument That Measures Student Perceptions of Teacher Credibility.

    ERIC Educational Resources Information Center

    Lapan, Stephen D.

    The purpose of this study was to develop and validate an instrument to collect student judgments regarding their teacher's credibility. Items were developed and evidence of content validity generated. A pilot sample and a final sample of high school students were administered the Source Credibility Measure (SCM) so that actual response data could…

  18. The Perinatal Palliative Care Perceptions and Barriers Scale Instrument©: development and validation.

    PubMed

    Wool, Charlotte; Northam, Sally

    2011-12-01

    To devise and test an instrument measuring clinician perceptions of perinatal palliative care (PPC) and barriers to care delivery. PPC was theorized to involve the care of pregnant women and their families after prenatal testing resulted in a life-limiting fetal diagnosis. Both giving birth to a child with a life-limiting condition or termination of pregnancy for fetal anomaly can be emotionally traumatic life events. Clinicians were thought to face ethical dilemmas that involved approaches to care for this population. The ethical dilemmas were measured on a perceptions scale using items about informed consent, justice, beneficence, and autonomy. Barriers were theorized as obstacles to delivering quality PPC and included insufficient education, personal discomfort, and difficulty garnering team or administrative support for care. Licensed clinicians practicing in the perinatal field. Stage 1 entailed instrument development and validation, which was achieved through a Delphi study involving 11 expert panelists. The devised instrument included 64 six-point Likert items. In stage 2, a computer survey gathered data from a multidisciplinary, clinician group. A total of 264 clinicians completed the survey. Exploratory factor analysis with varimax rotation was used to validate the instrument, evaluate the factors, and summarize the explained variance achieved by sum scores of the perceptions and barriers scales. The perceptions scale was reduced to 23 items with a 6-factor solution explaining 67% of the variance with a good internal consistency reliability of 0.77 (Cronbach α). The 22-item barriers scale had a 6-factor solution explaining 71% of the variance with an alpha reliability of 0.83. The Perinatal Palliative Care Perceptions and Practice Barriers Scale instrument is a valid and reliable measure of PPC perceptions and barriers for measuring the attitudes of physicians and nurses. Use of this instrument can foster educational programs and hospital planning for PPC

  19. [Design and implementation of medical instrument standard information retrieval system based on APS.NET].

    PubMed

    Yu, Kaijun

    2010-07-01

    This paper Analys the design goals of Medical Instrumentation standard information retrieval system. Based on the B /S structure,we established a medical instrumentation standard retrieval system with ASP.NET C # programming language, IIS f Web server, SQL Server 2000 database, in the. NET environment. The paper also Introduces the system structure, retrieval system modules, system development environment and detailed design of the system.

  20. Infrared instrument support for HyspIRI-TIR

    NASA Astrophysics Data System (ADS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2012-10-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  1. 49 CFR 572.103 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Test conditions and instrumentation. 572.103... Motion Headform § 572.103 Test conditions and instrumentation. (a) Headform accelerometers shall have... 1988, “Instrumentation for Impact Tests,” Class 1000 (incorporated by reference; see § 572.100). (c...

  2. 49 CFR 572.103 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Test conditions and instrumentation. 572.103... Motion Headform § 572.103 Test conditions and instrumentation. (a) Headform accelerometers shall have... 1988, “Instrumentation for Impact Tests,” Class 1000 (incorporated by reference; see § 572.100). (c...

  3. 49 CFR 572.103 - Test conditions and instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Test conditions and instrumentation. 572.103... Motion Headform § 572.103 Test conditions and instrumentation. (a) Headform accelerometers shall have... 1988, “Instrumentation for Impact Tests,” Class 1000 (incorporated by reference; see § 572.100). (c...

  4. 49 CFR 572.103 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Test conditions and instrumentation. 572.103... Motion Headform § 572.103 Test conditions and instrumentation. (a) Headform accelerometers shall have... 1988, “Instrumentation for Impact Tests,” Class 1000 (incorporated by reference; see § 572.100). (c...

  5. 49 CFR 572.103 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Test conditions and instrumentation. 572.103... Motion Headform § 572.103 Test conditions and instrumentation. (a) Headform accelerometers shall have... 1988, “Instrumentation for Impact Tests,” Class 1000 (incorporated by reference; see § 572.100). (c...

  6. 14 CFR 29.1303 - Flight and navigation instruments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flight and navigation instruments. 29.1303... navigation instruments. The following are required flight and navigational instruments: (a) An airspeed... sensitive altimeter. (c) A magnetic direction indicator. (d) A clock displaying hours, minutes, and seconds...

  7. Development and validation of climate change system thinking instrument (CCSTI) for measuring system thinking on climate change content

    NASA Astrophysics Data System (ADS)

    Meilinda; Rustaman, N. Y.; Firman, H.; Tjasyono, B.

    2018-05-01

    The Climate Change System Thinking Instrument (CCSTI) is developed to measure a system thinking ability in the concept of climate change. CCSTI is developed in four phase’s development including instrument draft development, validation and evaluation including readable material test, expert validation, and field test. The result of field test is analyzed by looking at the readability score in Cronbach’s alpha test. Draft instrument is tested on college students majoring in Biology Education, Physics Education, and Chemistry Education randomly with a total number of 80 college students. Score of Content Validation Index at 0.86, which means that the CCSTI developed are categorized as very appropriate with question indicators and Cronbach’s alpha about 0.605 which mean categorized undesirable to minimal acceptable. From 45 questions of system thinking, there are 37 valid questions spread in four indicators of system thinking, which are system thinking phase I (pre-requirement), system thinking phase II (basic), system thinking phase III (intermediate), and system thinking phase IV (coherent expert).

  8. Development and evaluation of an instrument to measure parental satisfaction with quality of care in neonatal follow-up.

    PubMed

    Butt, Michelle L; Pinelli, Janet; Boyle, Michael H; Thomas, Helen; Hunsberger, Mabel; Saigal, Saroj; Lee, David S; Fanning, Jamie K; Austin, Patricia

    2009-02-01

    The goal of this study was to develop and subsequently evaluate the psychometric properties of a new discriminative instrument to measure parental satisfaction with the quality of care provided in neonatal follow-up (NFU) programs. The methodological framework for developing and evaluating measurement scales described by Streiner and Norman (Health Measurement Scales: A Practical Guide to Their Development and Use. 3rd ed. New York: Oxford University Press; 2003) was used for the study. Informing the phases of the research was a sample of 24 health care professionals and 381 parents who use NFU services. A comprehensive list of items representing the construct, parental satisfaction with quality of care, was generated from published reliable and valid instruments, research studies, focus groups with health care experts, and focus groups with parents. Using a clinimetric approach, the 62 items generated were reduced to 39 items based on parents' ratings of importance and refinement of the items by the research team. After content validation and pretesting, the instrument was tested with parents and underwent item-analysis. The resulting 16-item instrument was composed of 2 subscales, Process and Outcomes. Evaluation of the instrument's psychometric properties indicated adequate test-retest reliability (intraclass correlation coefficient = 0.72) and internal consistency (Process subscale, alpha = 0.77; Outcomes subscale, alpha = 0.90; overall instrument, alpha = 0.90), as well as good content and construct validity. A confirmatory factor analysis supported the multidimensionality of the construct. This new instrument provides clinicians and policy-makers with a tool to assess parental satisfaction with the quality of care in NFU, so areas of dissatisfaction can be identified and changes implemented to optimize service provision.

  9. Partnering with patients using social media to develop a hypertension management instrument.

    PubMed

    Kear, Tamara; Harrington, Magdalena; Bhattacharya, Anand

    2015-09-01

    Hypertension is a lifelong condition; thus, long-term adherence to lifestyle modification, self-monitoring, and medication regimens remains a challenge for patients. The aim of this study was to develop a patient-reported hypertension instrument that measured attitudes, lifestyle behaviors, adherence, and barriers to hypertension management using patient-reported outcome data. The study was conducted using the Open Research Exchange software platform created by PatientsLikeMe. A total of 360 participants completed the psychometric phase of the study; incomplete responses were obtained from 147 patients, and 150 patients opted out. Principal component analysis with orthogonal (varimax) rotation was executed on a data set with all completed responses (N = 249) and applied to 43 items. Based on the review of the factor solution, eigenvalues, and item loadings, 16 items were eliminated and model with 29 items was tested. The process was repeated two more times until final model with 14 items was established. In interpreting the rotated factor pattern, an item was said to load on any given component if the factor loading was ≥0.40 for that component and was <0.40 for the other. In addition to the newly generated instrument, demographic and self-reported clinical characteristics of the study participants such as the type of prescribed hypertension medications, frequency of blood pressure monitoring, and comorbid conditions were examined. The Open Research Exchange platform allowed for ongoing input from patients through each stage of the 14-item instrument development. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Satisfaction with and Benefits of a Psych-social Club: Development of a Mixed Method Evaluation Instrument

    PubMed Central

    Labun, Evelyn; Yurkovich, Eleanor; Ide, Bette A.

    2015-01-01

    Deinstitutionalization of psychiatric mental health hospitals began in the 1960’s; thus, the delivery of mental health services became dependent on regional centers and community based, contracted services. One such service model is the psych-social club. Such clubs provide mental health services on the lower end of the cost continuum and reduce the utilization of higher cost services (Yurkovich, Labun, Cook & Lattergrass, 2005). This paper fills a gap by reporting on the development of a mixed method instrument entitled Benefits & Satisfaction Tool for Members of a Psych-social Club (B&ST-MPC). It also reports on the psychometric properties of the instrument, and measures members’ perception of satisfaction with and benefits of their psych-social club utilization, thus providing evaluative information for developing client centered continuums of care (Yurkovich et al., 2005). The paper includes a brief overview of the first mixed method study, background information on the rationale for instrument development, including methods used, and a discussion of the instrument’s psychometric properties. PMID:23164402

  11. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP)

    PubMed Central

    Bernhard, Gerda; Knibbe, Ronald A.; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Background Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs’ cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. Methods The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Results Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs’ cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension’s Cronbach’s α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. Conclusions The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs’ cultural competence. The CCCHP with its five dimensions offers a comprehensive

  12. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP).

    PubMed

    Bernhard, Gerda; Knibbe, Ronald A; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs' cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs' cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension's Cronbach's α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs' cultural competence. The CCCHP with its five dimensions offers a comprehensive assessment of HCPs' cultural competence, and has the

  13. Instrument Reporting Practices in Second Language Research

    ERIC Educational Resources Information Center

    Derrick, Deirdre J.

    2016-01-01

    Second language (L2) researchers often have to develop or change the instruments they use to measure numerous constructs (Norris & Ortega, 2012). Given the prevalence of researcher-developed and -adapted data collection instruments, and given the profound effect instrumentation can have on results, thorough reporting of instrumentation is…

  14. Interpersonal and Affective Dimensions of Psychopathic Traits in Adolescents: Development and Validation of a Self-Report Instrument

    ERIC Educational Resources Information Center

    Houghton, Stephen; Hunter, Simon C.; Khan, Umneea; Tan, Carol

    2013-01-01

    We report the development and psychometric evaluations of a self-report instrument designed to screen for psychopathic traits among mainstream community adolescents. Tests of item functioning were initially conducted with 26 adolescents. In a second study the new instrument was administered to 150 high school adolescents, 73 of who had school…

  15. Development and validation of EMP-3: an instrument to measure physician's attitudes toward ethnic minority patients.

    PubMed

    De Maesschalck, Stephanie; Willems, Sara; De Maeseneer, Jan; Deveugele, Myriam

    2010-04-01

    The growing diversity of patient populations challenges health care providers. Physicians' attitudes and perceptions toward cultural diversity in health care could be partly contributing to difficulties in communication between physicians and ethnic minority patients. To evaluate these attitudes and perceptions, an instrument was developed and validated. A preliminary version of the instrument was developed through literature research and expert consultation and completed by 112 family physicians. Factor analysis was performed and reliability and construct validity tested. The instrument revealed three factors that were interpreted as: (1) physicians' task perception and ideas on cultural differences in health and health care, (2) physicians' attitudes toward physician-patient communication with minority patients, and (3) physicians' perception of minority patients' needs in communication. Moderate but significant correlations were found between factors of the EMP-3 and practice organization, practice location, and physicians' gender. Several factors of the Jefferson Empathy Scale, the Patient Practitioner Orientation Scale, and the Health Beliefs and Attitude Scale related to the first two factors of the EMP-3. This instrument, designed specifically to measure physicians' attitudes toward cultural diversity, showed moderate validity and reliability results. Further adaptations and evaluation could be useful.

  16. Instrumentation at Paranal Observatory: maintaining the instrument suite of five large telescopes and its interferometer alive

    NASA Astrophysics Data System (ADS)

    Gillet, Gordon; Alvarez, José Luis; Beltrán, Juan; Bourget, Pierre; Castillo, Roberto; Diaz, Álvaro; Haddad, Nicolás; Leiva, Alfredo; Mardones, Pedro; O'Neal, Jared; Ribes, Mauricio; Riquelme, Miguel; Robert, Pascal; Rojas, Chester; Valenzuela, Javier

    2010-07-01

    This presentation provides interesting miscellaneous information regarding the instrumentation activities at Paranal Observatory. It introduces the suite of 23 instruments and auxiliary systems that are under the responsibility of the Paranal Instrumentation group, information on the type of instruments, their usage and downtime statistics. The data is based on comprehensive data recorded in the Paranal Night Log System and the Paranal Problem Reporting System whose principles are explained as well. The work organization of the 15 team members around the high number of instruments is laid out, which includes: - Maintaining older instruments with obsolete components - Receiving new instruments and supporting their integration and commissioning - Contributing to future instruments in their developing phase. The assignments of the Instrumentation staff to the actual instruments as well as auxiliary equipment (Laser Guide Star Facility, Mask Manufacturing Unit, Cloud Observation Tool) are explained with respect to responsibility and scheduling issues. The essential activities regarding hardware & software are presented, as well as the technical and organizational developments within the group towards its present and future challenges.

  17. Development of the Next Generation of Seismological Instrumentation for Polar Environments

    NASA Astrophysics Data System (ADS)

    Winberry, J. P.; Anderson, K. R.; Huerta, A. D.; Bernsen, S. P.; Parker, T.; Carpenter, P.; Woodward, R.; Beaudoin, B. C.; Bilek, S. L.

    2014-12-01

    Ice covered regions comprise >10% of Earth's continental area; and include regions with poorly understood ice dynamics, ice shelf stability, hydrology, tectonic histories and basic geologic structure both deep and shallow. Scientific investigations of these regions are challenged by extreme weather, limited and expensive logistics, and the physical conditions of the ice environment. We report on the next development of a new NSF MRI-supported community seismic capability for studying ice-covered regions- the Geophysical Earth Observatory for Ice Covered Environments (GEOICE). This project is fundamentally motivated by the need to densify and optimize the collection of high-quality data relevant to key solid Earth and cryosphere science questions. The instrument capability will include a hybrid seismograph pool of broadband and intermediate elements, for observation of both long-period (e.g., long-period surface waves and slow sources) and intermediate-to-short-period (e.g., teleseismic body waves local seismicity, impulsive or extended glaciogenic signals). The GEOICE instrument, and its power and other ancillary systems, will be specifically designed to both withstand conditions associated with icy environments, including cold/wet conditions and high-latitude solar limitations, and to require minimal installation time and logistical load (i.e., size and weight), while maximizing ease-of-use in the field, in data handling, and in telemetry compatibility. Key features will include a design that integrates the seismometer and data logger into a single environmentally and mechanically robust housing, very low power requirements (<~1 watt) for the intermediate-band systems, and advanced power/battery systems that optimize battery capacity and operational limits. The envisioned ~125 element GEOICE instruments will nearly double the current polar inventory of stations and will be maintained and supported at the IRIS PASSCAL Instrument Center to ensure full and flexible

  18. Development of a prototype version of an embeddable corrosivity measuring instrument for reinforced concrete.

    DOT National Transportation Integrated Search

    2002-01-01

    To address the problem of safely and quantifiably detecting corrosion in a cost-effective and timely manner, the University of Virginia and Virginia Technologies, Inc. have developed a remotely accessible, networked, embedded corrosion instrument. Th...

  19. Cost Effective Instrumentation for Developing Autonomous Groundwater Monitoring Networks

    NASA Astrophysics Data System (ADS)

    Viti, T. M.; Garmire, D. G.

    2017-12-01

    Despite a relatively poor understanding of Hawaiian groundwater systems, the State of Hawaii depends almost exclusively on groundwater for its public water supply. Ike Wai, an NSF funded project (EPSCoR Program Award OIA #1557349) at the University of Hawaii, aims to develop new groundwater models for Hawaii's aquifers, including water quality and transport processes. To better understand aquifer properties such as capacity and hydraulic conductivity, we are developing well-monitoring instruments that can autonomously record water parameters such as conductivity, temperature, and hydraulic head level, with sampling frequencies on the order of minutes. We are currently exploring novel methods and materials for solving classical design problems, such as applying dielectric spectroscopy techniques for measuring salinity, and using recycled materials for producing custom cable assemblies. System components are fabricated in house using rapid prototyping (e.g. 3D printing, circuit board milling, and laser cutting), and traditional manufacturing techniques. This approach allows us to produce custom components while minimizing development cost, and maximizing flexibility in the overall system's design.

  20. Trace Gas Retrievals from the GeoTASO Aircraft Instrument During the DISCOVER-AQ Campaigns

    NASA Astrophysics Data System (ADS)

    Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Kaptchen, P. F.; Loughner, C.; Follette-Cook, M. B.; Pickering, K. E.

    2014-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a recently-developed passive remote sensing instrument capable of making 2-D measurements of trace gases from aircraft. GeoTASO was developed under NASA's Instrument Incubator program and is a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey and the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite missions. The instrument collects spectra of backscattered UV-visible radiation for the detection of tropospheric trace gases such as NO2, ozone, formaldehyde and SO2. GeoTASO flew on the NASA HU-25C Falcon aircraft during the 2013 (Texas) and 2014 (Colorado) DISCOVER-AQ field campaigns, making satellite-analog measurements of trace gases at a spatial resolution of approximately 500x500 m over urban areas, power plants and other industrial sources of pollution. We present the GeoTASO retrieval algorithms, trace gas measurement results, and validation comparisons with ground-based observations and other aircraft instruments during these campaigns.

  1. An Instrument Development Study for Determining Prospective Science Teachers' Science-Specific Epistemological Beliefs

    ERIC Educational Resources Information Center

    Koksal, Mustafa Serdar; Ertekin, Pelin

    2016-01-01

    The study is focusing on development of an instrument to determine science-specific epistemological beliefs of prospective science teachers. The study involved 364 (male = 82, female = 282) prospective science teachers enrolled in a science teacher education program. The confirmatory factor analysis, reliability analysis and correlation analysis…

  2. Prediction of wood mechanical and chemical properties in the presence and absence of blue stain using two near infrared instruments

    Treesearch

    Brian K. Via; Chi-Leung So; Todd F. Shupe; Lori G. Eckhardt; Michael Stine; Leslie H. Groom

    2005-01-01

    The objective of this research was to (a) determine if blue stain in solid wood influenced calibration equations developed from a nonstained wood population, (b) assess the bias introduced when scanning was performed by the slave instrument without calibration transfer from the master instrument and (c) partition absorbance-based variation by instrument, stain and...

  3. Development and Validation of an Instrument to Assess the Implementation of Family-Centred Care in Traditional Open Bay Neonatal Intensive Care Units

    ERIC Educational Resources Information Center

    Al-Motlaq, Mohammad A.; Abuidhail, Jamila; Salameh, Taghreed; Awwad, Wesam

    2017-01-01

    Objective: To develop an instrument to study family-centred care (FCC) in traditional open bay Neonatal Intensive Care Units (NICUs). Methods: The development process involved constructing instrument's items, establishing content validity by an expert panel and testing the instrument for validity and reliability with a convenience sample of 25…

  4. Development and application of a novel crop stress and quality instrument

    NASA Astrophysics Data System (ADS)

    Huang, Wengjiang; Sun, Gang; Wang, Jihua; Liu, Liangyun; Zheng, Wengang

    2005-12-01

    In this paper, a portable diagnostic instrument for crop quality analysis was designed and tested, which can measure the normalized difference vegetation index (PRI) and structure insensitive pigment index (NRI) of crop canopy in the field. The instrument have a valid survey area of 1m×1m when the height between instrument and the ground was fixed to 1.3 meter. The crop quality can be assessed based on their PRI and NRI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field. Such simple instruments can diagnose the plant growth status by the acquired spectral response.

  5. Lab-on-a-Chip Instrument Development for Titan Exploration

    NASA Astrophysics Data System (ADS)

    Willis, P. A.; Greer, F.; Fisher, A.; Hodyss, R. P.; Grunthaner, F.; Jiao, H.; Mair, D.; Harrison, J.

    2009-12-01

    This contribution will describe the initial stages of a new ASTID-funded research program initiated in Fall 2009 aimed at lab-on-a-chip system development for astrobiological investigations on Titan. This technology development builds off related work at JPL and Berkeley [1-3] on the ultrasensitive compositional and chiral analysis of amino acids on Mars in order to search for signatures of past or present life. The Mars-focused instrument system utilizes a microcapillary electrophoresis (μCE) system integrated with on-chip perfluoropolyether (PFPE) membrane valves and pumps for automated liquid sample handling, on-chip derivitization of samples with fluorescent tags, dilution, and mixing with standards for data calibration. It utilizes a four-layer wafer stack design with CE channels patterned in glass, along with a PFPE membrane, a pneumatic manifold layer, and a fluidic bus layer. Three pneumatically driven on-chip diaphragm valves placed in series are used to peristaltically pump reagents, buffers, and samples to and from capillary electrophoresis electrode well positions. Electrophoretic separation occurs in the all-glass channels near the base of the structure. The Titan specific lab-on-a-chip system under development here focuses its attention on the unique organic chemistry of Titan. In order to chromatographically separate mixtures of neutral organics such as polycyclic aromatic hydrocarbons (PAHs), the Titan-specific microfluidic platform utilizes the related technique of microcapillary electrochromatography (μCEC). This technique differs from conventional μCE in that microchannels are filled with a porous stationary phase that presents surfaces upon which analyte species can adsorb/desorb. It is this additional surface interaction that enables separations of species critical to the understanding of the astrobiological potential of Titan that are not readily separated by the μCE technique. We have developed two different approaches for the integration

  6. Sonar Test and Test Instrumentation Support.

    DTIC Science & Technology

    1979-03-29

    AD-AlSO 055 TEXAS UNIV AT AUSTIN APPLIED RESEARCH LABS F/6 17/1 SONAR TEST AND TEST INSTRUMENTATION SUPPORT (U) MAR 79 0 D BAKER N00140-76-C-64a7... SONAR TEST AND TEST INSTRUMENTATION SUPPORT quarterly progress report September - 30 November 197Pj 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(e) S...involves technical support with sonar testing, test instrumentation, and documentation. This report describes progress made under the tasks that are

  7. Development and Testing of UCLA's Electron Losses and Fields Investigation (ELFIN) Instrument Payload

    NASA Astrophysics Data System (ADS)

    Wilkins, C.; Bingley, L.; Angelopoulos, V.; Caron, R.; Cruce, P. R.; Chung, M.; Rowe, K.; Runov, A.; Liu, J.; Tsai, E.

    2017-12-01

    UCLA's Electron Losses and Fields Investigation (ELFIN) is a 3U+ CubeSat mission designed to study relativistic particle precipitation in Earth's polar regions from Low Earth Orbit. Upon its 2018 launch, ELFIN will aim to address an important open question in Space Physics: Are Electromagnetic Ion-Cyclotron (EMIC) waves the dominant source of pitch-angle scattering of high-energy radiation belt charged particles into Earth's atmosphere during storms and substorms? Previous studies have indicated these scattering events occur frequently during storms and substorms, and ELFIN will be the first mission to study this process in-situ.Paramount to ELFIN's success is its instrument suite consisting of an Energetic Particle Detector (EPD) and a Fluxgate Magnetometer (FGM). The EPD is comprised of two collimated solid-state detector stacks which will measure the incident flux of energetic electrons from 50 keV to 4 MeV and ions from 50 keV to 300 keV. The FGM is a 3-axis magnetic field sensor which will capture the local magnetic field and its variations at frequencies up to 5 Hz. The ELFIN spacecraft spins perpendicular to the geomagnetic field to provide 16 pitch-angle particle data sectors per revolution. Together these factors provide the capability to address the nature of radiation belt particle precipitation by pitch-angle scattering during storms and substorms.ELFIN's instrument development has progressed into the late Engineering Model (EM) phase and will soon enter Flight Model (FM) development. The instrument suite is currently being tested and calibrated at UCLA using a variety of methods including the use of radioactive sources and applied magnetics to simulate orbit conditions during spin sectoring. We present the methods and test results from instrument calibration and performance validation.

  8. Development and evaluation of the OHCITIES instrument: assessing alcohol urban environments in the Heart Healthy Hoods project

    PubMed Central

    Sureda, Xisca; Espelt, Albert; Villalbí, Joan R; Cebrecos, Alba; Baranda, Lucía; Pearce, Jamie; Franco, Manuel

    2017-01-01

    Objectives To describe the development and test–retest reliability of OHCITIES, an instrument characterising alcohol urban environment in terms of availability, promotion and signs of consumption. Design This study involved: (1) developing the conceptual framework for alcohol urban environment by means of literature reviewing and previous alcohol environment research experience; (2) pilot testing and redesigning the instrument; (3) instrument digitalisation; (4) instrument evaluation using test–retest reliability. Setting Data for testing the reliability of the instrument were collected in seven census sections in Madrid in 2016 by two observers. Primary and secondary outcome measures We computed per cent agreement and Cohen’s kappa coefficients to estimate inter-rater and test–retest reliability for alcohol outlet environment measures. We calculated interclass coefficients and their 95% CIs to provide a measure of inter-rater reliability for signs of alcohol consumption measures. Results We collected information on 92 on-premise and 24 off-premise alcohol outlets identified in the studied areas about availability, accessibility and promotion of alcohol. Most per cent-agreement values for alcohol measures in on-premise and off-premise alcohol outlets were greater than 80%, and inter-rater and test–retest reliability values were generally above 0.80. Observers identified 26 streets and 3 public squares with signs of alcohol consumption. Intraclass correlation coefficient between observers for any type of signs of alcohol consumption was 0.50 (95% CI −0.09 to 0.77). Few items promoting alcohol unrelated to alcohol outlets were found on public spaces. Conclusions The OHCITIES instrument is a reliable instrument to characterise alcohol urban environment. This instrument might be used to understand how alcohol environment associates with alcohol behaviours and its related health outcomes, and can help in the design and evaluation of policies to reduce the

  9. Development and Validation of an Instrument to Assess Student Attitudes toward Science across Grades 5 through 10

    ERIC Educational Resources Information Center

    Summers, Ryan; Abd-El-Khalick, Fouad

    2018-01-01

    The aim of the present study is to enable future studies into students' attitudes toward science, and related constructs, by developing and validating an instrument suitable for cross-sectional designs. Following a thorough review of the literature it was determined that many extant instruments included design aspects that appeared to be limited…

  10. Development of optical components for METIS instrument

    NASA Astrophysics Data System (ADS)

    Nardello, M.; Zuccon, S.; Corso, A. J.; Zuppella, P.; Naletto, G.; Fineschi, S.; Antonucci, E.; Pelizzo, M. G.

    2014-09-01

    The ESA mission Solar Orbiter (SOLO) is dedicated to the study of Solar Atmosphere and Heliosphere. As a part of the payload, the instrument METIS (Multi Element Telescope for Imaging and Spectroscopy) will provide images of the corona, both in the visible range and at the hydrogen Lyman-α emission line (121.6 nm). The realization of optical coatings, based on Al and MgF2, able to reflect/transmit such spectral component is therefore necessary. Since optical characteristics of materials in the VUV range are not well studied and greatly varying with realization process, we implemented a study of their properties in different deposition conditions. This is aimed to the realization of a custom designed filter, able to transmit the 121.6 nm while reflecting the visible light, and thus separate visible from UV light paths in the METIS instrument.

  11. Note: Measuring instrument of singlet oxygen quantum yield in photodynamic effects

    NASA Astrophysics Data System (ADS)

    Li, Zhongwei; Zhang, Pengwei; Zang, Lixin; Qin, Feng; Zhang, Zhiguo; Zhang, Hongli

    2017-06-01

    Using diphenylisobenzofuran (C20H14O) as a singlet oxygen (1O2) reporter, a comparison method, which can be used to measure the singlet oxygen quantum yield (ΦΔ) of the photosensitizer quantitatively, is presented in this paper. Based on this method, an automatic measuring instrument of singlet oxygen quantum yield is developed. The singlet oxygen quantum yield of the photosensitizer hermimether and aloe-emodin is measured. It is found that the measuring results are identical to the existing ones, which verifies the validity of the measuring instrument.

  12. The Development of an Instrument to Measure the Project Competences of College Students in Online Project-Based Learning

    NASA Astrophysics Data System (ADS)

    Lin, Chien-Liang

    2018-02-01

    This study sought to develop a self-report instrument to be used in the assessment of the project competences of college students engaged in online project-based learning. Three scales of the KIPSSE instrument developed for this study, namely, the knowledge integration, project skills, and self-efficacy scales, were based on related theories and the analysis results of three project advisor interviews. Those items of knowledge integration and project skill scales focused on the integration of different disciplines and technological skills separately. Two samples of data were collected from information technology-related courses taught with an online project-based learning strategy over different semesters at a college in southern Taiwan. The validity and reliability of the KIPSSE instrument were confirmed through item analysis and confirmatory factor analysis using structural equation modeling of two samples of students' online response sets separately. The Cronbach's alpha reliability coefficient for the entire instrument was 0.931; for each scale, the alpha ranged from 0.832 to 0.907. There was also a significant correlation ( r = 0.55, p < 0.01) between the KIPSSE instrument results and the students' product evaluation scores. The findings of this study confirmed the validity and reliability of the KIPSSE instrument. The confirmation process and related implications are also discussed.

  13. [Development of an instrument to measure psychosocial determinants of physical activity behavior among coronary heart disease patients].

    PubMed

    Mendez, Roberto Della Rosa; Rodrigues, Roberta Cunha Matheus; Cornélio, Marilia Estevam; Gallani, Maria Cecília Bueno Jayme; Godin, Gaston

    2010-09-01

    The aim of this study was to report the development and the analysis of content validity and reliability of the Psychosocial Determinants of Physical Activity among Coronary Heart Disease Patients Questionnaire, based on an extension of the Theory of Planned Behavior. In the content validity step, three experts evaluated the instrument which was, afterwards, pre-tested with five subjects in order to obtain a conceptually appropriate and easily understood instrument. Fifty-one patients participated in the evaluation of internal consistency of the reviewed instrument. Cronbach's alpha coefficients above 0.75 were observed for the constructs: Intention, Attitude, Subjective Norm, Self-efficacy and Habit. The new instrument demonstrated acceptable evidence of content validity and reliability.

  14. Sonar Test and Test Instrumentation Support.

    DTIC Science & Technology

    1976-11-10

    AD-AI0 � TEXAS UNIV AT AUSTIN APPLIED RESEARCH LARS F/6 17/1 SONAR TEST AND TEST INSTRUMENTATION SUPPDRT.1U) NoV 76 0 0 BAKER N00140-76-C-&687...UNCLASSIFIED_ NL i 0 00 THE UNIVERSITY OF TEXAS AT AUSTIN 10 November 1976 Copy No. 3 SONAR TEST AND TEST INSTRUMENTATION SUPPORT Quarterly Progress...8217 mi a - I TABLE OF CONTENTS A pag. I. INTRODUCTION 1 II. AN/FQM-IO(V) SONAR TEST SET FIELD SUPPORT 3 A. Introduction 3 B. Visit to NAVSHIPYD PEARL 3 C

  15. THE DEVELOPMENT OF AN INSTRUMENT FOR MEASURING THE UNDERSTANDING OF PROFIT-MAXIMIZING PRINCIPLES.

    ERIC Educational Resources Information Center

    MCCORMICK, FLOYD G.

    THE PURPOSE OF THE STUDY WAS TO DEVELOP AN INSTRUMENT FOR MEASURING PROFIT-MAXIMIZING PRINCIPLES IN FARM MANAGEMENT WITH IMPLICATIONS FOR VOCATIONAL AGRICULTURE. PRINCIPLES WERE IDENTIFIED FROM LITERATURE SELECTED BY AGRICULTURAL ECONOMISTS. FORTY-FIVE MULTIPLE-CHOICE QUESTIONS WERE REFINED ON THE BASIS OF RESULTS OF THREE PRETESTS AND…

  16. Factor analysis methods and validity evidence: A systematic review of instrument development across the continuum of medical education

    NASA Astrophysics Data System (ADS)

    Wetzel, Angela Payne

    Previous systematic reviews indicate a lack of reporting of reliability and validity evidence in subsets of the medical education literature. Psychology and general education reviews of factor analysis also indicate gaps between current and best practices; yet, a comprehensive review of exploratory factor analysis in instrument development across the continuum of medical education had not been previously identified. Therefore, the purpose for this study was critical review of instrument development articles employing exploratory factor or principal component analysis published in medical education (2006--2010) to describe and assess the reporting of methods and validity evidence based on the Standards for Educational and Psychological Testing and factor analysis best practices. Data extraction of 64 articles measuring a variety of constructs that have been published throughout the peer-reviewed medical education literature indicate significant errors in the translation of exploratory factor analysis best practices to current practice. Further, techniques for establishing validity evidence tend to derive from a limited scope of methods including reliability statistics to support internal structure and support for test content. Instruments reviewed for this study lacked supporting evidence based on relationships with other variables and response process, and evidence based on consequences of testing was not evident. Findings suggest a need for further professional development within the medical education researcher community related to (1) appropriate factor analysis methodology and reporting and (2) the importance of pursuing multiple sources of reliability and validity evidence to construct a well-supported argument for the inferences made from the instrument. Medical education researchers and educators should be cautious in adopting instruments from the literature and carefully review available evidence. Finally, editors and reviewers are encouraged to recognize

  17. Development and Validation of an Assessment Instrument for Course Experience in a General Education Integrated Science Course

    ERIC Educational Resources Information Center

    Liu, Juhong Christie; St. John, Kristen; Courtier, Anna M. Bishop

    2017-01-01

    Identifying instruments and surveys to address geoscience education research (GER) questions is among the high-ranked needs in a 2016 survey of the GER community (St. John et al., 2016). The purpose of this study was to develop and validate a student-centered assessment instrument to measure course experience in a general education integrated…

  18. Developing Instruments to Assess and Compare the Quality of Engineering Education: The Case of China and Russia

    ERIC Educational Resources Information Center

    Kardanova, Elena; Loyalka, Prashant; Chirikov, Igor; Liu, Lydia; Li, Guirong; Wang, Huan; Enchikova, Ekaterina; Shi, Henry; Johnson, Natalie

    2016-01-01

    Relatively little is known about differences in the quality of engineering education within and across countries because of the lack of valid instruments that allow for the assessment and comparison of engineering students' skill gains. The purpose of our study is to develop and validate instruments that can be used to compare student skill gains…

  19. Development of an instrument to analyze organizational characteristics in multidisciplinary care pathways; the case of colorectal cancer.

    PubMed

    Pluimers, Dorine J; van Vliet, Ellen J; Niezink, Anne Gh; van Mourik, Martijn S; Eddes, Eric H; Wouters, Michel W; Tollenaar, Rob A E M; van Harten, Wim H

    2015-04-09

    To analyze the organization of multidisciplinary care pathways such as colorectal cancer care, an instrument was developed based on a recently published framework that was earlier used in analyzing (monodisciplinary) specialist cataract care from a lean perspective. The instrument was constructed using semi-structured interviews and direct observation of the colorectal care process based on a Rapid Plant Assessment. Six lean aspects that were earlier established that highly impact process design, were investigated: operational focus, autonomous work cell, physical lay-out of resources, multi-skilled team, pull planning and non-value adding activities. To test reliability, clarity and face validity of the instrument, a pilot study was performed in eight Dutch hospitals. In the pilot it proved feasible to apply the instrument and generate the intended information. The instrument consisted of 83 quantitative and 24 qualitative items. Examples of results show differences in operational focus, number of patient visits needed for diagnosis, numbers of staff involved with treatment, the implementation of protocols and utilization of one-stop-shops. Identification of waste and non-value adding activities may need further attention. Based on feedback from involved clinicians the face validity was acceptable and the results provided useful feedback- and benchmark data. The instrument proved to be reliable and valid for broader implementation in Dutch health care. The limited number of cases made statistical analysis not possible and further validation studies may shed better light on variation. This paper demonstrates the use of an instrument to analyze organizational characteristics in colorectal cancer care from a lean perspective. Wider use might help to identify best organizational practices for colorectal surgery. In larger series the instrument might be used for in-depth research into the relation between organization and patient outcomes. Although we found no reason

  20. Development of the Lidar Atmospheric Sensing Experiment (LASE): An Advanced Airborne DIAL Instrument

    NASA Technical Reports Server (NTRS)

    Moore, Alvah S., Jr.; Brown, Kevin E.; Hall, William M.; Barnes, James C.; Edwards, William C.; Petway, Larry B.; Little, Alan D.; Luck, William S., Jr.; Jones, Irby W.; Antill, Charles W., Jr.

    1997-01-01

    The Lidar Atmospheric Sensing Experiment (LASE) Instrument is the first fully-engineered, autonomous Differential Absorption Lidar (DIAL) System for the measurement of water vapor in the troposphere (aerosol and cloud measurements are included). LASE uses a double-pulsed Ti:Sapphire laser for the transmitter with a 30 ns pulse length and 150 mJ/pulse. The laser beam is "seeded" to operate on a selected water vapor absorption line in the 815-nm region using a laser diode and an onboard absorption reference cell. A 40 cm diameter telescope collects the backscattered signals and directs them onto two detectors. LASE collects DIAL data at 5 Hz while onboard a NASA/Ames ER-2 aircraft flying at altitudes from 16-21 km. LASE was designed to operate autonomously within the environment and physical constraints of the ER-2 aircraft and to make water vapor profile measurements across the troposphere to better than 10% accuracy. LASE has flown 19 times during the development of the instrument and the validation of the science data. This paper describes the design, operation, and reliability of the LASE Instrument.