Sample records for icd-o-3 site icd-o-3

  1. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akter, Jesmin; Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp; Islam, Md. Sazzadul

    2014-10-10

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus duringmore » ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.« less

  2. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation.

    PubMed

    Akter, Jesmin; Takatori, Atsushi; Islam, Md Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira

    2014-10-10

    We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Schuger, Claudio; Goldenberg, Ilan; Klein, Helmut; Aktas, Mehmet K; McNitt, Scott; Stockburger, Martin; Merkely, Bela; Zareba, Wojciech; Moss, Arthur J

    2016-01-01

    The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25-0.57; P<0.001). High-rate cut-off or delayed ventricular tachycardia therapy programming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; P<0.001 for all). There was a significant reduction in inappropriate anti-tachycardia pacings in both group and a significant reduction in inappropriate ICD shock in CRT-D patients. Patients implanted with a CRT-D have lower risk of inappropriate ICD therapy than those with an ICD. Innovative ICD programming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. http://clinicaltrials.gov; Unique identifier: NCT00947310. © 2016 American Heart Association, Inc.

  4. Conducting Retrospective Ontological Clinical Trials in ICD-9-CM in the Age of ICD-10-CM.

    PubMed

    Venepalli, Neeta K; Shergill, Ardaman; Dorestani, Parvaneh; Boyd, Andrew D

    2014-01-01

    To quantify the impact of International Classification of Disease 10th Revision Clinical Modification (ICD-10-CM) transition in cancer clinical trials by comparing coding accuracy and data discontinuity in backward ICD-10-CM to ICD-9-CM mapping via two tools, and to develop a standard ICD-9-CM and ICD-10-CM bridging methodology for retrospective analyses. While the transition to ICD-10-CM has been delayed until October 2015, its impact on cancer-related studies utilizing ICD-9-CM diagnoses has been inadequately explored. Three high impact journals with broad national and international readerships were reviewed for cancer-related studies utilizing ICD-9-CM diagnoses codes in study design, methods, or results. Forward ICD-9-CM to ICD-10-CM mapping was performing using a translational methodology with the Motif web portal ICD-9-CM conversion tool. Backward mapping from ICD-10-CM to ICD-9-CM was performed using both Centers for Medicare and Medicaid Services (CMS) general equivalence mappings (GEMs) files and the Motif web portal tool. Generated ICD-9-CM codes were compared with the original ICD-9-CM codes to assess data accuracy and discontinuity. While both methods yielded additional ICD-9-CM codes, the CMS GEMs method provided incomplete coverage with 16 of the original ICD-9-CM codes missing, whereas the Motif web portal method provided complete coverage. Of these 16 codes, 12 ICD-9-CM codes were present in 2010 Illinois Medicaid data, and accounted for 0.52% of patient encounters and 0.35% of total Medicaid reimbursements. Extraneous ICD-9-CM codes from both methods (Centers for Medicare and Medicaid Services general equivalent mapping [CMS GEMs, n = 161; Motif web portal, n = 246]) in excess of original ICD-9-CM codes accounted for 2.1% and 2.3% of total patient encounters and 3.4% and 4.1% of total Medicaid reimbursements from the 2010 Illinois Medicare database. Longitudinal data analyses post-ICD-10-CM transition will require backward ICD-10-CM to ICD-9-CM

  5. Simulation of ICD-9 to ICD-10-CM Transition for Family Medicine: Simple or Convoluted?

    PubMed

    Grief, Samuel N; Patel, Jesal; Kochendorfer, Karl M; Green, Lee A; Lussier, Yves A; Li, Jianrong; Burton, Michael; Boyd, Andrew D

    2016-01-01

    The objective of this study was to examine the impact of the transition from International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM), to Interactional Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM), on family medicine and to identify areas where additional training might be required. Family medicine ICD-9-CM codes were obtained from an Illinois Medicaid data set (113,000 patient visits and $5.5 million in claims). Using the science of networks, we evaluated each ICD-9-CM code used by family medicine physicians to determine whether the transition was simple or convoluted. A simple transition is defined as 1 ICD-9-CM code mapping to 1 ICD-10-CM code, or 1 ICD-9-CM code mapping to multiple ICD-10-CM codes. A convoluted transition is where the transitions between coding systems is nonreciprocal and complex, with multiple codes for which definitions become intertwined. Three family medicine physicians evaluated the most frequently encountered complex mappings for clinical accuracy. Of the 1635 diagnosis codes used by family medicine physicians, 70% of the codes were categorized as simple, 27% of codes were convoluted, and 3% had no mapping. For the visits, 75%, 24%, and 1% corresponded with simple, convoluted, and no mapping, respectively. Payment for submitted claims was similarly aligned. Of the frequently encountered convoluted codes, 3 diagnosis codes were clinically incorrect, but they represent only <0.1% of the overall diagnosis codes. The transition to ICD-10-CM is simple for 70% or more of diagnosis codes, visits, and reimbursement for a family medicine physician. However, some frequently used codes for disease management are convoluted and incorrect, and for which additional resources need to be invested to ensure a successful transition to ICD-10-CM. © Copyright 2016 by the American Board of Family Medicine.

  6. Simulation of ICD-9 to ICD-10-CM transition for family medicine: simple or convoluted?

    PubMed Central

    Grief, Samuel N.; Patel, Jesal; Lussier, Yves A.; Li, Jianrong; Burton, Michael; Boyd, Andrew D.

    2017-01-01

    Objectives The objective of this study was to examine the impact of the transition from International Classification of Disease Version Nine Clinical Modification (ICD-9-CM) to Interactional Classification of Disease Version Ten Clinical Modification (ICD-10-CM) on family medicine and identify areas where additional training might be required. Methods Family medicine ICD-9-CM codes were obtained from an Illinois Medicaid data set (113,000 patient visits and $5.5 million dollars in claims). Using the science of networks we evaluated each ICD-9-CM code used by family medicine physicians to determine if the transition was simple or convoluted.1 A simple translation is defined as one ICD-9-CM code mapping to one ICD-10-CM code or one ICD-9-CM code mapping to multiple ICD-10-CM codes. A convoluted transition is where the transitions between coding systems is non-reciprocal and complex with multiple codes where definitions become intertwined. Three family medicine physicians evaluated the most frequently encountered complex mappings for clinical accuracy. Results Of the 1635 diagnosis codes used by the family medicine physicians, 70% of the codes were categorized as simple, 27% of the diagnosis codes were convoluted and 3% were found to have no mapping. For the visits, 75%, 24%, and 1% corresponded with simple, convoluted, and no mapping, respectively. Payment for submitted claims were similarly aligned. Of the frequently encountered convoluted codes, 3 diagnosis codes were clinically incorrect, but they represent only < 0.1% of the overall diagnosis codes. Conclusions The transition to ICD-10-CM is simple for 70% or more of diagnosis codes, visits, and reimbursement for a family medicine physician. However, some frequently used codes for disease management are convoluted and incorrect, where additional resources need to be invested to ensure a successful transition to ICD-10-CM. PMID:26769875

  7. The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial.

    PubMed

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina; McNitt, Scott; Thomsen, Poul Erik Bloch; Klein, Helmut; Stockburger, Martin; Wichterle, Dan; Merkely, Bela; DE LA Concha, Joaquin Fernandez; Swissa, Moshe; Zareba, Wojciech; Moss, Arthur J; Kautzner, Josef; Ruwald, Martin H

    2015-04-01

    The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy. © 2014 Wiley Periodicals, Inc.

  8. Heart failure severity, inappropriate ICD therapy, and novel ICD programming: a MADIT-RIT substudy.

    PubMed

    Daimee, Usama A; Vermilye, Katherine; Rosero, Spencer; Schuger, Claudio D; Daubert, James P; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Moss, Arthur J; Kutyifa, Valentina

    2017-12-01

    The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P < 0.001) and CRT-D patients (HR = 3.73, CI: 1.14-12.23, P = 0.030). This was consistent for inappropriate ATP and inappropriate ICD therapy < 200 beats/min, but not for inappropriate shocks. Novel ICD programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P < 0.001; Arm C vs Arm A: HR = 0.17, P < 0.001) and NYHA I-II (Arm B vs Arm A: HR = 0.25, P < 0.001; Arm C vs Arm A: HR = 0.28, P < 0.001). Patients with more severe HF are at increased risk for inappropriate ICD therapy, particularly ATP due to arrhythmias < 200 beats/min. Novel programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF. © 2017 Wiley Periodicals, Inc.

  9. Development of structured ICD-10 and its application to computer-assisted ICD coding.

    PubMed

    Imai, Takeshi; Kajino, Masayuki; Sato, Megumi; Ohe, Kazuhiko

    2010-01-01

    This paper presents: (1) a framework of formal representation of ICD10, which functions as a bridge between ontological information and natural language expressions; and (2) a methodology to use formally described ICD10 for computer-assisted ICD coding. First, we analyzed and structurized the meanings of categories in 15 chapters of ICD10. Then we expanded the structured ICD10 (S-ICD10) by adding subordinate concepts and labels derived from Japanese Standard Disease Names. The information model to describe formal representation was refined repeatedly. The resultant model includes 74 types of semantic links. We also developed an ICD coding module based on S-ICD10 and a 'Coding Principle,' which achieved high accuracy (>70%) for four chapters. These results not only demonstrate the basic feasibility of our coding framework but might also inform the development of the information model for formal description framework in the ICD11 revision.

  10. Comparison of ICD-10 and DC: 0-3R Diagnoses in Infants, Toddlers and Preschoolers

    ERIC Educational Resources Information Center

    Equit, Monika; Paulus, Frank; Fuhrmann, Pia; Niemczyk, Justine; von Gontard, Alexander

    2011-01-01

    The purpose of this study was to analyze and compare diagnoses of patients from a special outpatient department for infants, toddlers and preschoolers. Specifically, overlap, age and gender differences according to the two classification systems DC: 0-3R and ICD-10 were examined. 299 consecutive children aged 0-5;11 years received both ICD-10 and…

  11. Open-access programs for injury categorization using ICD-9 or ICD-10.

    PubMed

    Clark, David E; Black, Adam W; Skavdahl, David H; Hallagan, Lee D

    2018-04-09

    The article introduces Programs for Injury Categorization, using the International Classification of Diseases (ICD) and R statistical software (ICDPIC-R). Starting with ICD-8, methods have been described to map injury diagnosis codes to severity scores, especially the Abbreviated Injury Scale (AIS) and Injury Severity Score (ISS). ICDPIC was originally developed for this purpose using Stata, and ICDPIC-R is an open-access update that accepts both ICD-9 and ICD-10 codes. Data were obtained from the National Trauma Data Bank (NTDB), Admission Year 2015. ICDPIC-R derives CDC injury mechanism categories and an approximate ISS ("RISS") from either ICD-9 or ICD-10 codes. For ICD-9-coded cases, RISS is derived similar to the Stata package (with some improvements reflecting user feedback). For ICD-10-coded cases, RISS may be calculated in several ways: The "GEM" methods convert ICD-10 to ICD-9 (using General Equivalence Mapping tables from CMS) and then calculate ISS with options similar to the Stata package; a "ROCmax" method calculates RISS directly from ICD-10 codes, based on diagnosis-specific mortality in the NTDB, maximizing the C-statistic for predicting NTDB mortality while attempting to minimize the difference between RISS and ISS submitted by NTDB registrars (ISSAIS). Findings were validated using data from the National Inpatient Survey (NIS, 2015). NTDB contained 917,865 cases, of which 86,878 had valid ICD-10 injury codes. For a random 100,000 ICD-9-coded cases in NTDB, RISS using the GEM methods was nearly identical to ISS calculated by the Stata version, which has been previously validated. For ICD-10-coded cases in NTDB, categorized ISS using any version of RISS was similar to ISSAIS; for both NTDB and NIS cases, increasing ISS was associated with increasing mortality. Prediction of NTDB mortality was associated with C-statistics of 0.81 for ISSAIS, 0.75 for RISS using the GEM methods, and 0.85 for RISS using the ROCmax method; prediction of NIS mortality

  12. Validation of the Combined Comorbidity Index of Charlson and Elixhauser to Predict 30-Day Mortality Across ICD-9 and ICD-10.

    PubMed

    Simard, Marc; Sirois, Caroline; Candas, Bernard

    2018-05-01

    To validate and compare performance of an International Classification of Diseases, tenth revision (ICD-10) version of a combined comorbidity index merging conditions of Charlson and Elixhauser measures against individual measures in the prediction of 30-day mortality. To select a weight derivation method providing optimal performance across ICD-9 and ICD-10 coding systems. Using 2 adult population-based cohorts of patients with hospital admissions in ICD-9 (2005, n=337,367) and ICD-10 (2011, n=348,820), we validated a combined comorbidity index by predicting 30-day mortality with logistic regression. To appreciate performance of the Combined index and both individual measures, factors impacting indices performance such as population characteristics and weight derivation methods were accounted for. We applied 3 scoring methods (Van Walraven, Schneeweiss, and Charlson) and determined which provides best predictive values. Combined index [c-statistics: 0.853 (95% confidence interval: CI, 0.848-0.856)] performed better than original Charlson [0.841 (95% CI, 0.835-0.844)] or Elixhauser [0.841 (95% CI, 0.837-0.844)] measures on ICD-10 cohort. All weight derivation methods provided close high discrimination results for the Combined index (Van Walraven: 0.852, Schneeweiss: 0.851, Charlson: 0.849). Results were consistent across both coding systems. The Combined index remains valid with both ICD-9 and ICD-10 coding systems and the 3 weight derivation methods evaluated provided consistent high performance across those coding systems.

  13. New Methodology for an Expert-Designed Map From International Classification of Diseases (ICD) to Abbreviated Injury Scale (AIS) 3+ Severity Injury.

    PubMed

    Zonfrillo, Mark R; Weaver, Ashley A; Gillich, Patrick J; Price, Janet P; Stitzel, Joel D

    2015-01-01

    There has been a longstanding desire for a map to convert International Classification of Diseases (ICD) injury codes to Abbreviated Injury Scale (AIS) codes to reflect the severity of those diagnoses. The Association for the Advancement of Automotive Medicine (AAAM) was tasked by European Union representatives to create a categorical map classifying diagnoses codes as serious injury (Abbreviated Injury Scale [AIS] 3+), minor/moderate injury (AIS 1/2), or indeterminate. This study's objective was to map injury-related ICD-9-CM (clinical modification) and ICD-10-CM codes to these severity categories. Approximately 19,000 ICD codes were mapped, including injuries from the following categories: amputations, blood vessel injury, burns, crushing injury, dislocations/sprains/strains, foreign body, fractures, internal organ, nerve/spinal cord injury, intracranial, laceration, open wounds, and superficial injury/contusion. Two parallel activities were completed to create the maps: (1) An in-person expert panel and (2) an electronic survey. The panel consisted of expert users of AIS and ICD from North America, the United Kingdom, and Australia. The panel met in person for 5 days, with follow-up virtual meetings to create and revise the maps. Additional qualitative data were documented to resolve potential discrepancies in mapping. The electronic survey was completed by 95 injury coding professionals from North America, Spain, Australia, and New Zealand over 12 weeks. ICD-to-AIS maps were created for: ICD-9-CM and ICD-10-CM. Both maps indicated whether the corresponding AIS 2005/Update 2008 severity score for each ICD code was AIS 3+, 1/2, or indeterminable. Though some ICD codes could be mapped to multiple AIS codes, the maximum severity of all potentially mapped injuries determined the final severity categorization. The in-person panel consisted of 13 experts, with 11 Certified AIS specialists (CAISS) with a median of 8 years and an average of 15 years of coding experience

  14. PS3-11: Beyond General Equivalency Mappings (GEMs): Understanding the Implications of ICD 10 in Research

    PubMed Central

    Riordan, Rick

    2013-01-01

    Background/Aims With the implementation of ICD 10 CM and ICD 10 PCS less than two years away, there are still unanswered questions as to how research teams will effectively translate or use ICD 10 codes in research. Approximately 84% of the ICD 10 codes have only approximate matches with 10% having multiple matches and only 5% have exact one-to-one matches between ICD 9 and ICD 10. With the number of codes increasing five-fold, this offers additional opportunities and risks when pulling data. Methods Besides looking at the General Equivalency Mappings and other tools that are used to translate ICD 9 codes to ICD 10 codes, we will examine some common research areas where only approximate matches between ICD 9 and ICD 10 exist. We will also discuss how the finer level of detail that ICD 10 gives allows research teams to pinpoint exactly what type of asthma, Crohn’s disease, and diabetic retinopathy they wish to study without including some of the other cases that do not meet their research criteria. Results There are significant ambiguities and irregularity in several common areas such as diabetes, mental health, asthma, and gastroenterology due to approximate, multiple, or combination matches. Even in the case of exact matches such as an old myocardial infarction where there is an exact match, the definition of when a myocardial infarction becomes “old” is different. Conclusions ICD 10 offers a finer level of detail and a higher level of specificity, thereby allowing research teams to be more targeted when pulling data. On the other hand, research teams need to exercise caution when using GEMs and other tools to translate ICD 9 codes into ICD 10 codes and vice versa, especially if they are looking at data that overlaps the implementation date of October 1, 2014.

  15. [Cause-of-death statistics and ICD, quo vadis?

    PubMed

    Eckert, Olaf; Vogel, Ulrich

    2018-07-01

    The International Statistical Classification of Diseases and Related Health Problems (ICD) is the worldwide binding standard for generating underlying cause-of-death statistics. What are the effects of former revisions of the ICD on underlying cause-of-death statistics and which opportunities and challenges are becoming apparent in a possible transition process from ICD-10 to ICD-11?This article presents the calculation of the exploitation grade of ICD-9 and ICD-10 in the German cause-of-death statistics and quality of documentation. Approximately 67,000 anonymized German death certificates are processed by Iris/MUSE and official German cause-of-death statistics are analyzed.In addition to substantial changes in the exploitation grade in the transition from ICD-9 to ICD-10, regional effects become visible. The rate of so-called "ill-defined" conditions exceeds 10%.Despite substantial improvement of ICD revisions there are long-known deficits in the coroner's inquest, filling death certificates and quality of coding. To make better use of the ICD as a methodological framework for mortality statistics and health reporting in Germany, the following measures are necessary: 1. General use of Iris/MUSE, 2. Establishing multiple underlying cause-of-death statistics, 3. Introduction of an electronic death certificate, 4. Improvement of the medical assessment of cause of death.Within short time the WHO will release the 11th revision of the ICD that will provide additional opportunities for the development of underlying cause-of-death statistics and their use in science, public health and politics. A coordinated effort including participants in the process and users is necessary to meet the related challenges.

  16. [Impact of attachment style, social support and the number of implantable cardioverter defibrillator (ICD) discharges on psychological strain of ICD patients].

    PubMed

    Simson, Udo; Perings, Christian; Plaskuda, Ariane; Schäfer, Ralf; Brehm, Michael; Bader, Doris; Tress, Wolfgang; Franz, Matthias

    2006-12-01

    OBJECTIVE It is well known fact, that the life of ICD patients is often affected by anxiety and depression. The number of ICD discharges is only a contributing factor explaining the variance of anxiety and depression. There have to be other factors that have more influence on the physical strain of ICD patients. In this study we examined the impact of attachment style and social support in addition to the number of ICD discharges. METHODS 119 out-patients at an out-patient ICD unit were examined consecutively with the following self report scales: (1) the State-Trait-Anxiety Inventory (STAI), (2) the Beck Depression Inventory (BDI), (3) a short form of a social support questionnaire (F-SOZU), (4) the Bielefeld Partnership Expectations Questionnaire (BFPE) and (5) a specifically designed questionnaire for the assessment of sociodemografic data. To determine the frequency and timing of the ICD discharges we analysed the ICD data. RESULTS 38 % of the ICD patients reported enhanced anxiety levels and 37 % reported enhanced depression levels. Only 38 % of the ICD patients received discharges at all. Elevated levels of anxiety and depression were found in patients who showed insecure attachment styles, low social support, long-term treatment in hospital and a higher number of ICD discharges. To explain the variance of anxiety we found social support, attachment style, and the number of ICD storms to be contributing factors. To explain the variance of depression we found social support and time spent in hospital in the previous year to be contributing factors. CONCLUSIONS Almost half of the ICD patients suffer considerably from anxiety and/or depression. These patients have to be identified and treated psychotherapeutically. Patients who show insecure attachment styles, receive low social support, undergo long-term treatment in hospital and receive a higher number of discharges, especially so called ICD storms, bear the highest risk to develop psychological strain

  17. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation.

    PubMed

    Dyers, Robin; Ward, Grant; Du Plooy, Shane; Fourie, Stephanus; Evans, Juliet; Mahomed, Hassan

    2017-05-24

    The proposed National Health Insurance policy for South Africa (SA) requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD) codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2) adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  18. Far-Infrared Emission of Intracluster Dust (ICD)

    NASA Astrophysics Data System (ADS)

    Arimoto, N.; Takagi, T.; Hanami, H.

    2000-12-01

    In the young universe, clusters of galaxies could be bright FIR-Submm sources due to the dust emissions from young ellipticals. The intracluster dust (ICD) could also contribute to the FIR-Submm emissions considerably, but the ICD is fragile in the ambient hot ICM. Therefore, a chance to detect the ICD emission would be much smaller than the dust emissions from galaxies. Dust emissions from elliptical galaxies (EROs) in the young Coma cluster at a distance of z=2-3 would be easily detected by a future mission of H2L2 satellite, thus the FIR-Submm survey would become a powerful tool for searching high-z clusters.

  19. [Restrictions for ICD patients in daily life].

    PubMed

    Köbe, Julia; Gradaus, Rainer; Zumhagen, Sven; Böcker, Dirk

    2005-11-01

    Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging

  20. Development of the ICD-10 simplified version and field test.

    PubMed

    Paoin, Wansa; Yuenyongsuwan, Maliwan; Yokobori, Yukiko; Endo, Hiroyoshi; Kim, Sukil

    2018-05-01

    The International Statistical Classification of Diseases and Related Health Problems, 10th Revision (ICD-10) has been used in various Asia-Pacific countries for more than 20 years. Although ICD-10 is a powerful tool, clinical coding processes are complex; therefore, many developing countries have not been able to implement ICD-10-based health statistics (WHO-FIC APN, 2007). This study aimed to simplify ICD-10 clinical coding processes, to modify index terms to facilitate computer searching and to provide a simplified version of ICD-10 for use in developing countries. The World Health Organization Family of International Classifications Asia-Pacific Network (APN) developed a simplified version of the ICD-10 and conducted field testing in Cambodia during February and March 2016. Ten hospitals were selected to participate. Each hospital sent a team to join a training workshop before using the ICD-10 simplified version to code 100 cases. All hospitals subsequently sent their coded records to the researchers. Overall, there were 1038 coded records with a total of 1099 ICD clinical codes assigned. The average accuracy rate was calculated as 80.71% (66.67-93.41%). Three types of clinical coding errors were found. These related to errors relating to the coder (14.56%), those resulting from the physician documentation (1.27%) and those considered system errors (3.46%). The field trial results demonstrated that the APN ICD-10 simplified version is feasible for implementation as an effective tool to implement ICD-10 clinical coding for hospitals. Developing countries may consider adopting the APN ICD-10 simplified version for ICD-10 code assignment in hospitals and health care centres. The simplified version can be viewed as an introductory tool which leads to the implementation of the full ICD-10 and may support subsequent ICD-11 adoption.

  1. MW-assisted synthesis of SVO for ICD primary batteries

    NASA Astrophysics Data System (ADS)

    Beninati, Sabina; Fantuzzi, Matteo; Mastragostino, Marina; Soavi, Francesca

    An Ag 2V 4O 11 (SVO) cathode material prepared by microwave (MW)-assisted solid-state synthesis (MW-SVO) was developed for lithium primary batteries for implantable cardioverter/defibrillators (ICDs). This paper presents the results of physical-chemical and electrochemical characterizations of MW-SVO as well as those of SVO prepared by conventional thermal route (T-SVO). A specific effect of MWs which accelerates the synthesis reaction and contributes to yield a material of different morphology and degree of crystallinity compared with those of T-SVO was observed. The results of pulsed electrochemical tests carried out at 37 °C in operative conditions of ICDs on Li/MW-SVO batteries with cathode mass loading sized for practical use are also reported. These tests demonstrated that MW-SVO can be used for high performing lithium primary battery delivering in few seconds the specific energy values required by ICD application.

  2. Development of an expert based ICD-9-CM and ICD-10-CM map to AIS 2005 update 2008.

    PubMed

    Loftis, Kathryn L; Price, Janet P; Gillich, Patrick J; Cookman, Kathy J; Brammer, Amy L; St Germain, Trish; Barnes, Jo; Graymire, Vickie; Nayduch, Donna A; Read-Allsopp, Christine; Baus, Katherine; Stanley, Patsye A; Brennan, Maureen

    2016-09-01

    This article describes how maps were developed from the clinical modifications of the 9th and 10th revisions of the International Classification of Diseases (ICD) to the Abbreviated Injury Scale 2005 Update 2008 (AIS08). The development of the mapping methodology is described, with discussion of the major assumptions used in the process to map ICD codes to AIS severities. There were many intricacies to developing the maps, because the 2 coding systems, ICD and AIS, were developed for different purposes and contain unique classification structures to meet these purposes. Experts in ICD and AIS analyzed the rules and coding guidelines of both injury coding schemes to develop rules for mapping ICD injury codes to the AIS08. This involved subject-matter expertise, detailed knowledge of anatomy, and an in-depth understanding of injury terms and definitions as applied in both taxonomies. The official ICD-9-CM and ICD-10-CM versions (injury sections) were mapped to the AIS08 codes and severities, following the rules outlined in each coding manual. The panel of experts was composed of coders certified in ICD and/or AIS from around the world. In the process of developing the map from ICD to AIS, the experts created rules to address issues with the differences in coding guidelines between the 2 schemas and assure a consistent approach to all codes. Over 19,000 ICD codes were analyzed and maps were generated for each code to AIS08 chapters, AIS08 severities, and Injury Severity Score (ISS) body regions. After completion of the maps, 14,101 (74%) of the eligible 19,012 injury-related ICD-9-CM and ICD-10-CM codes were assigned valid AIS08 severity scores between 1 and 6. The remaining 4,911 codes were assigned an AIS08 of 9 (unknown) or were determined to be nonmappable because the ICD description lacked sufficient qualifying information for determining severity according to AIS rules. There were also 15,214 (80%) ICD codes mapped to AIS08 chapter and ISS body region, which

  3. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.

    PubMed

    Weems, Shelley; Heller, Pamela; Fenton, Susan H

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.

  4. ICD-10 classification in Danish child and adolescent psychiatry--have diagnoses changed after the introduction of ICD-10?

    PubMed

    Møller, Lene Ruge; Sørensen, Merete Juul; Thomsen, Per Hove

    2007-01-01

    The aim was to test this in a nationwide register study of diagnoses used in child and adolescents psychiatry in Denmark. A larger number of different diagnoses were expected to be applied after the introduction of the 10th version of the International Classification of Diseases (ICD-10). Reflecting the time trend, we particularly expected an increase in the number of neuropsychiatric diagnoses. From the Danish Psychiatric Central Register data were drawn on clinical discharge diagnoses. All patients aged 0-15 years examined at psychiatric hospitals from 1995-2002 were included; 22,469 children and adolescents with a first contact were registered. The most frequent discharge diagnoses were pervasive development disorders (PDD; 11.9%), adjustment disorders (10.6%), conduct disorder (9.5%), emotional and anxiety disorders (7.6%), hyperkinetic disorders (7.3%), and specific developmental disorders (7.3%). We found a significant increase in the number of neuropsychiatric and affective diagnoses and a significant decrease in the number of adjustment, conduct and anxiety diagnoses during the study period. Of the 22,469 diagnoses, 45% were only partly specified according to ICD-10. Thirty-four per cent had diagnoses unspecified on the four-character level (Fxx.9) and 11% had Z-diagnoses. A larger number of different diagnoses and an increase in the use of neuropsychiatric diagnoses were seen after the introduction of ICD-10. Many diagnoses were only partly specified; consequently, a more detailed specification of the ICD-10 is still required.

  5. ICD-10 procedure codes produce transition challenges

    PubMed Central

    Boyd, Andrew D.; Li, Jianrong ‘John’; Kenost, Colleen; Zaim, Samir Rachid; Krive, Jacob; Mittal, Manish; Satava, Richard A.; Burton, Michael; Smith, Jacob; Lussier, Yves A.

    2018-01-01

    The transition of procedure coding from ICD-9-CM-Vol-3 to ICD-10-PCS has generated problems for the medical community at large resulting from the lack of clarity required to integrate two non-congruent coding systems. We hypothesized that quantifying these issues with network topology analyses offers a better understanding of the issues, and therefore we developed solutions (online tools) to empower hospital administrators and researchers to address these challenges. Five topologies were identified: “identity”(I), “class-to-subclass”(C2S), “subclass-toclass”(S2C), “convoluted(C)”, and “no mapping”(NM). The procedure codes in the 2010 Illinois Medicaid dataset (3,290 patients, 116 institutions) were categorized as C=55%, C2S=40%, I=3%, NM=2%, and S2C=1%. Majority of the problematic and ambiguous mappings (convoluted) pertained to operations in ophthalmology cardiology, urology, gyneco-obstetrics, and dermatology. Finally, the algorithms were expanded into a user-friendly tool to identify problematic topologies and specify lists of procedural codes utilized by medical professionals and researchers for mitigating error-prone translations, simplifying research, and improving quality.http://www.lussiergroup.org/transition-to-ICD10PCS PMID:29888037

  6. ICD-10 procedure codes produce transition challenges.

    PubMed

    Boyd, Andrew D; Li, Jianrong 'John'; Kenost, Colleen; Zaim, Samir Rachid; Krive, Jacob; Mittal, Manish; Satava, Richard A; Burton, Michael; Smith, Jacob; Lussier, Yves A

    2018-01-01

    The transition of procedure coding from ICD-9-CM-Vol-3 to ICD-10-PCS has generated problems for the medical community at large resulting from the lack of clarity required to integrate two non-congruent coding systems. We hypothesized that quantifying these issues with network topology analyses offers a better understanding of the issues, and therefore we developed solutions (online tools) to empower hospital administrators and researchers to address these challenges. Five topologies were identified: "identity"(I), "class-to-subclass"(C2S), "subclass-toclass"(S2C), "convoluted(C)", and "no mapping"(NM). The procedure codes in the 2010 Illinois Medicaid dataset (3,290 patients, 116 institutions) were categorized as C=55%, C2S=40%, I=3%, NM=2%, and S2C=1%. Majority of the problematic and ambiguous mappings (convoluted) pertained to operations in ophthalmology cardiology, urology, gyneco-obstetrics, and dermatology. Finally, the algorithms were expanded into a user-friendly tool to identify problematic topologies and specify lists of procedural codes utilized by medical professionals and researchers for mitigating error-prone translations, simplifying research, and improving quality.http://www.lussiergroup.org/transition-to-ICD10PCS.

  7. Clinical implications of the proposed ICD-11 PTSD diagnostic criteria.

    PubMed

    Barbano, Anna C; van der Mei, Willem F; Bryant, Richard A; Delahanty, Douglas L; deRoon-Cassini, Terri A; Matsuoka, Yutaka J; Olff, Miranda; Qi, Wei; Ratanatharathorn, Andrew; Schnyder, Ulrich; Seedat, Soraya; Kessler, Ronald C; Koenen, Karestan C; Shalev, Arieh Y

    2018-05-14

    Projected changes to post-traumatic stress disorder (PTSD) diagnostic criteria in the upcoming International Classification of Diseases (ICD)-11 may affect the prevalence and severity of identified cases. This study examined differences in rates, severity, and overlap of diagnoses using ICD-10 and ICD-11 PTSD diagnostic criteria during consecutive assessments of recent survivors of traumatic events. The study sample comprised 3863 survivors of traumatic events, evaluated in 11 longitudinal studies of PTSD. ICD-10 and ICD-11 diagnostic rules were applied to the Clinician-Administered PTSD Scale (CAPS) to derive ICD-10 and ICD-11 diagnoses at different time intervals between trauma occurrence and 15 months. The ICD-11 criteria identified fewer cases than the ICD-10 across assessment intervals (range -47.09% to -57.14%). Over 97% of ICD-11 PTSD cases met concurrent ICD-10 PTSD criteria. PTSD symptom severity of individuals identified by the ICD-11 criteria (CAPS total scores) was 31.38-36.49% higher than those identified by ICD-10 criteria alone. The latter, however, had CAPS scores indicative of moderate PTSD. ICD-11 was associated with similar or higher rates of comorbid mood and anxiety disorders. Individuals identified by either ICD-10 or ICD-11 shortly after traumatic events had similar longitudinal course. This study indicates that significantly fewer individuals would be diagnosed with PTSD using the proposed ICD-11 criteria. Though ICD-11 criteria identify more severe cases, those meeting ICD-10 but not ICD-11 criteria remain in the moderate range of PTSD symptoms. Use of ICD-11 criteria will have critical implications for case identification in clinical practice, national reporting, and research.

  8. Leveraging the NLM map from SNOMED CT to ICD-10-CM to facilitate adoption of ICD-10-CM.

    PubMed

    Cartagena, F Phil; Schaeffer, Molly; Rifai, Dorothy; Doroshenko, Victoria; Goldberg, Howard S

    2015-05-01

    Develop and test web services to retrieve and identify the most precise ICD-10-CM code(s) for a given clinical encounter. Facilitate creation of user interfaces that 1) provide an initial shortlist of candidate codes, ideally visible on a single screen; and 2) enable code refinement. To satisfy our high-level use cases, the analysis and design process involved reviewing available maps and crosswalks, designing the rule adjudication framework, determining necessary metadata, retrieving related codes, and iteratively improving the code refinement algorithm. The Partners ICD-10-CM Search and Mapping Services (PI-10 Services) are SOAP web services written using Microsoft's.NET 4.0 Framework, Windows Communications Framework, and SQL Server 2012. The services cover 96% of the Partners problem list subset of SNOMED CT codes that map to ICD-10-CM codes and can return up to 76% of the 69,823 billable ICD-10-CM codes prior to creation of custom mapping rules. We consider ways to increase 1) the coverage ratio of the Partners problem list subset of SNOMED CT codes and 2) the upper bound of returnable ICD-10-CM codes by creating custom mapping rules. Future work will investigate the utility of the transitive closure of SNOMED CT codes and other methods to assist in custom rule creation and, ultimately, to provide more complete coverage of ICD-10-CM codes. ICD-10-CM will be easier for clinicians to manage if applications display short lists of candidate codes from which clinicians can subsequently select a code for further refinement. The PI-10 Services support ICD-10 migration by implementing this paradigm and enabling users to consistently and accurately find the best ICD-10-CM code(s) without translation from ICD-9-CM. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    PubMed

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  10. An evaluation of ICD-11 posttraumatic stress disorder criteria in two samples of adolescents and young adults exposed to mass shootings: factor analysis and comparisons to ICD-10 and DSM-IV.

    PubMed

    Haravuori, Henna; Kiviruusu, Olli; Suomalainen, Laura; Marttunen, Mauri

    2016-05-12

    The proposed posttraumatic stress disorder (PTSD) criteria for the International Classification of Diseases (ICD) 11th revision are simpler than the criteria in ICD-10, DSM-IV or DSM-5. The aim of this study was to evaluate the ICD-11 PTSD factor structure in samples of young people, and to compare PTSD prevalence rates and diagnostic agreement between the different diagnostic systems. Possible differences in clinical characteristics of the PTSD cases identified by ICD-11, ICD-10 and DSM-IV are explored. Two samples of adolescents and young adults were followed after exposure to similar mass shooting incidents in their schools. Semi-structured diagnostic interviews were performed to assess psychiatric diagnoses and PTSD symptom scores (N = 228, mean age 17.6 years). PTSD symptom item scores were used to compose diagnoses according to the different classification systems. Confirmatory factor analyses indicated that the proposed ICD-11 PTSD symptoms represented two rather than three factors; re-experiencing and avoidance symptoms comprised one factor and hyperarousal symptoms the other factor. In the studied samples, the three-factor ICD-11 criteria identified 51 (22.4%) PTSD cases, the two-factor ICD-11 identified 56 (24.6%) cases and the DSM-IV identified 43 (18.9%) cases, while the number of cases identified by ICD-10 was larger, being 85 (37.3%) cases. Diagnostic agreement of the ICD-11 PTSD criteria with ICD-10 and DSM-IV was moderate, yet the diagnostic agreement turned to be good when an impairment criterion was imposed on ICD-10. Compared to ICD-11, ICD-10 identified cases with less severe trauma exposure and posttraumatic symptoms and DSM-IV identified cases with less severe trauma exposure. The findings suggest that the two-factor model of ICD-11 PTSD is preferable to the three-factor model. The proposed ICD-11 criteria are more restrictive compared to the ICD-10 criteria. There were some differences in the clinical characteristics of the PTSD cases

  11. Generator replacement is associated with an increased rate of ICD lead alerts.

    PubMed

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. [Sudden cardiac death in the youth. Is the new subcutaneous implantable cardioverter defibrillator S-ICD an alternative solution?].

    PubMed

    Roche, N-C; Stefuriac, M; Dumitrescu, N; Charbonnel, A; Godreuil, C; Bonnevie, L

    2015-02-01

    Implantable cardioverter defibrillator (ICD) is well-recognized therapy to prevent sudden cardiac death. Classic ICD need the use of permanent endocavitary leads, which may cause serious troubles (lead dislodgement, ventricular perforation, lead infections, etc.). The subcutaneous implantable cardioverter defibrillator (S-ICD) is a new device provided by only a subcutaneous lead. It has been developed for the last five years and it is becoming at present a real alternative to classic ICD. We report a clinical case of a 34 y.o. woman who presented a sudden cardiac death and who benefited the implantation of this new technology. This paper deals with the potential indications, usefulness benefits, and problems of the S-ICD. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. Greater Prevalence of Proposed ICD-11 Alcohol and Cannabis Dependence Compared to ICD-10, DSM-IV, and DSM-5 in Treated Adolescents.

    PubMed

    Chung, Tammy; Cornelius, Jack; Clark, Duncan; Martin, Christopher

    2017-09-01

    Proposed International Classification of Diseases, 11th edition (ICD-11), criteria for substance use disorder (SUD) radically simplify the algorithm used to diagnose substance dependence. Major differences in case identification across DSM and ICD impact determinations of treatment need and conceptualizations of substance dependence. This study compared the draft algorithm for ICD-11 SUD against DSM-IV, DSM-5, and ICD-10, for alcohol and cannabis. Adolescents (n = 339, ages 14 to 18) admitted to intensive outpatient addictions treatment completed, as part of a research study, a Structured Clinical Interview for DSM SUDs adapted for use with adolescents and which has been used to assess DSM and ICD SUD diagnoses. Analyses examined prevalence across classification systems, diagnostic concordance, and sources of diagnostic disagreement. Prevalence of any past-year proposed ICD-11 alcohol or cannabis use disorder was significantly lower compared to DSM-IV and DSM-5 (ps < 0.01). However, prevalence of proposed ICD-11 alcohol and cannabis dependence diagnoses was significantly higher compared to DSM-IV, DSM-5, and ICD-10 (ps < 0.01). ICD-11 and DSM-5 SUD diagnoses showed only moderate concordance. For both alcohol and cannabis, youth typically met criteria for an ICD-11 dependence diagnosis by reporting tolerance and much time spent using or recovering from the substance, rather than symptoms indicating impaired control over use. The proposed ICD-11 dependence algorithm appears to "overdiagnose" dependence on alcohol and cannabis relative to DSM-IV and ICD-10 dependence, and DSM-5 moderate/severe use disorder, generating potential "false-positive" cases of dependence. Among youth who met criteria for proposed ICD-11 dependence, few reported impaired control over substance use, highlighting ongoing issues in the conceptualization and diagnosis of SUD. Copyright © 2017 by the Research Society on Alcoholism.

  14. A self-report measure for the ICD-11 dimensional trait model proposal: The personality inventory for ICD-11.

    PubMed

    Oltmanns, Joshua R; Widiger, Thomas A

    2018-02-01

    Proposed for the 11th edition of the World Health Organization's International Classification of Diseases (ICD-11) is a dimensional trait model for the classification of personality disorder (Tyrer, Reed, & Crawford, 2015). The ICD-11 proposal consists of 5 broad domains: negative affective, detachment, dissocial, disinhibition, and anankastic (Mulder, Horwood, Tyrer, Carter, & Joyce, 2016). Several field trials have examined this proposal, yet none has included a direct measure of the trait model. The purpose of the current study was to develop and provide initial validation for the Personality Inventory for ICD-11 (PiCD), a self-report measure of this proposed 5-domain maladaptive trait model. Item selection and scale construction proceeded through 3 initial data collections assessing potential item performance. Two subsequent studies were conducted for scale validation. In Study 1, the PiCD was evaluated in a sample of 259 MTurk participants (who were or had been receiving mental health treatment) with respect to 2 measures of general personality structure: The Eysenck Personality Questionnaire-Revised and the 5-Dimensional Personality Test. In Study 2, the PiCD was evaluated in an additional sample of 285 participants with respect to 2 measures of maladaptive personality traits: The Personality Inventory for DSM-5 and the Computerized Adaptive Test for Personality Disorders. Study 3 provides an item-level exploratory structural equation model with the combined samples from Studies 1 and 2. The results are discussed with respect to the validity of the measure and the potential benefits for future research in having a direct, self-report measure of the ICD-11 trait proposal. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel.

    PubMed

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives: This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p  < .001). Provisional PTSD prevalence was significantly increased under ICD-11 proposal compared to ICD-10 (30%) which was mainly due to the deletion of the time criterion. Agreement between ICD-10 and the proposed ICD-11 was low ( p  = .014). Conclusion: This study provides preliminary evidence for a satisfactory concordance between provisional PTSD prevalence based on the diagnostic criteria for PTSD that are defined using DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10

  16. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel

    PubMed Central

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    ABSTRACT Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives:This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p < .001). Provisional PTSD prevalence was significantly increased under ICD-11 proposal compared to ICD-10 (30%) which was mainly due to the deletion of the time criterion. Agreement between ICD-10 and the proposed ICD-11 was low (p = .014). Conclusion: This study provides preliminary evidence for a satisfactory concordance between provisional PTSD prevalence based on the diagnostic criteria for PTSD that are defined using DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD

  17. Live Virtual Constructive (LVC): Interface Control Document (ICD) for the LVC Gateway. [Flight Test 3

    NASA Technical Reports Server (NTRS)

    Jovic, Srba

    2015-01-01

    This Interface Control Document (ICD) documents and tracks the necessary information required for the Live Virtual and Constructive (LVC) systems components as well as protocols for communicating with them in order to achieve all research objectives captured by the experiment requirements. The purpose of this ICD is to clearly communicate all inputs and outputs from the subsystem components.

  18. Measuring diagnoses: ICD code accuracy.

    PubMed

    O'Malley, Kimberly J; Cook, Karon F; Price, Matt D; Wildes, Kimberly Raiford; Hurdle, John F; Ashton, Carol M

    2005-10-01

    To examine potential sources of errors at each step of the described inpatient International Classification of Diseases (ICD) coding process. The use of disease codes from the ICD has expanded from classifying morbidity and mortality information for statistical purposes to diverse sets of applications in research, health care policy, and health care finance. By describing a brief history of ICD coding, detailing the process for assigning codes, identifying where errors can be introduced into the process, and reviewing methods for examining code accuracy, we help code users more systematically evaluate code accuracy for their particular applications. We summarize the inpatient ICD diagnostic coding process from patient admission to diagnostic code assignment. We examine potential sources of errors at each step and offer code users a tool for systematically evaluating code accuracy. Main error sources along the "patient trajectory" include amount and quality of information at admission, communication among patients and providers, the clinician's knowledge and experience with the illness, and the clinician's attention to detail. Main error sources along the "paper trail" include variance in the electronic and written records, coder training and experience, facility quality-control efforts, and unintentional and intentional coder errors, such as misspecification, unbundling, and upcoding. By clearly specifying the code assignment process and heightening their awareness of potential error sources, code users can better evaluate the applicability and limitations of codes for their particular situations. ICD codes can then be used in the most appropriate ways.

  19. Measuring Diagnoses: ICD Code Accuracy

    PubMed Central

    O'Malley, Kimberly J; Cook, Karon F; Price, Matt D; Wildes, Kimberly Raiford; Hurdle, John F; Ashton, Carol M

    2005-01-01

    Objective To examine potential sources of errors at each step of the described inpatient International Classification of Diseases (ICD) coding process. Data Sources/Study Setting The use of disease codes from the ICD has expanded from classifying morbidity and mortality information for statistical purposes to diverse sets of applications in research, health care policy, and health care finance. By describing a brief history of ICD coding, detailing the process for assigning codes, identifying where errors can be introduced into the process, and reviewing methods for examining code accuracy, we help code users more systematically evaluate code accuracy for their particular applications. Study Design/Methods We summarize the inpatient ICD diagnostic coding process from patient admission to diagnostic code assignment. We examine potential sources of errors at each step and offer code users a tool for systematically evaluating code accuracy. Principle Findings Main error sources along the “patient trajectory” include amount and quality of information at admission, communication among patients and providers, the clinician's knowledge and experience with the illness, and the clinician's attention to detail. Main error sources along the “paper trail” include variance in the electronic and written records, coder training and experience, facility quality-control efforts, and unintentional and intentional coder errors, such as misspecification, unbundling, and upcoding. Conclusions By clearly specifying the code assignment process and heightening their awareness of potential error sources, code users can better evaluate the applicability and limitations of codes for their particular situations. ICD codes can then be used in the most appropriate ways. PMID:16178999

  20. The Tragedy of the Implementation of ICD-10-CM as ICD-10: Is the Cart Before the Horse or Is There a Tragic Paradox of Misinformation and Ignorance?

    PubMed

    Manchikanti, Laxmaiah; Kaye, Alan D; Singh, Vijay; Boswell, Mark V

    2015-01-01

    Information Management Association (AHIMA). The AHIMA has taken the lead with the AHA just behind, both with escalating profits and influence, essentially creating a statutory monopoly for their own benefit. Further, the ICD-10-CM coalition includes 3M which will boost its revenues and profits substantially with its implementation and Blue Cross Blue Shield which has its own agenda. Physician groups are not a party to these cooperating parties or coalitions, having only a peripheral involvement. ICD-10-CM creates numerous deficiencies with 500 codes that are more specific in ICD-9-CM than ICD-10-CM. The costs of an implementation are enormous, along with maintenance costs, productivity, and cash disruptions.

  1. ICD-9-CM and ICD-10-CM mapping of the AAST Emergency General Surgery disease severity grading systems: Conceptual approach, limitations, and recommendations for the future.

    PubMed

    Utter, Garth H; Miller, Preston R; Mowery, Nathan T; Tominaga, Gail T; Gunter, Oliver; Osler, Turner M; Ciesla, David J; Agarwal, Suresh K; Inaba, Kenji; Aboutanos, Michel B; Brown, Carlos V R; Ross, Steven E; Crandall, Marie L; Shafi, Shahid

    2015-05-01

    The American Association for the Surgery of Trauma (AAST) recently established a grading system for uniform reporting of anatomic severity of several emergency general surgery (EGS) diseases. There are five grades of severity for each disease, ranging from I (lowest severity) to V (highest severity). However, the grading process requires manual chart review. We sought to evaluate whether International Classification of Diseases, 9th and 10th Revisions, Clinical Modification (ICD-9-CM, ICD-10-CM) codes might allow estimation of AAST grades for EGS diseases. The Patient Assessment and Outcomes Committee of the AAST reviewed all available ICD-9-CM and ICD-10-CM diagnosis codes relevant to 16 EGS diseases with available AAST grades. We then matched grades for each EGS disease with one or more ICD codes. We used the Official Coding Guidelines for ICD-9-CM and ICD-10-CM and the American Hospital Association's "Coding Clinic for ICD-9-CM" for coding guidance. The ICD codes did not allow for matching all five AAST grades of severity for each of the 16 diseases. With ICD-9-CM, six diseases mapped into four categories of severity (instead of five), another six diseases into three categories of severity, and four diseases into only two categories of severity. With ICD-10-CM, five diseases mapped into four categories of severity, seven diseases into three categories, and four diseases into two categories. Two diseases mapped into discontinuous categories of grades (two in ICD-9-CM and one in ICD-10-CM). Although resolution is limited, ICD-9-CM and ICD-10-CM diagnosis codes might have some utility in roughly approximating the severity of the AAST grades in the absence of more precise information. These ICD mappings should be validated and refined before widespread use to characterize EGS disease severity. In the long-term, it may be desirable to develop alternatives to ICD-9-CM and ICD-10-CM codes for routine collection of disease severity characteristics.

  2. The development, evolution, and modifications of ICD-10: challenges to the international comparability of morbidity data.

    PubMed

    Jetté, Nathalie; Quan, Hude; Hemmelgarn, Brenda; Drosler, Saskia; Maass, Christina; Moskal, Lori; Paoin, Wansa; Sundararajan, Vijaya; Gao, Song; Jakob, Robert; Ustün, Bedihran; Ghali, William A

    2010-12-01

    The United States is about to make a major nationwide transition from ICD-9-CM coding of hospital discharges to ICD-10-CM, a country-specific modification of the World Health Organization's ICD-10. As this transition occurs, the WHO is already in the midst of developing ICD-11. Given this context, we undertook this review to discuss: (1) the history of the International Classification of Diseases (a core information "building block" for health systems everywhere) from its introduction to the current era of ICD-11 development; (2) differences across country-specific ICD-10 clinical modifications and the challenges that these differences pose to the international comparability of morbidity data; (3) potential strategic approaches to achieving better international ICD-11 comparability. A literature review and stakeholder consultation was carried out. The various ICD-10 clinical modifications (ICD-10-AM [Australia], ICD-10-CA [Canada], ICD-10-GM [Germany], ICD-10-TM [Thailand], ICD-10-CM [United States]) were compared. These ICD-10 modifications differ in their number of codes, chapters, and subcategories. Specific conditions are present in some but not all of the modifications. ICD-11, with a similar structure to ICD-10, will function in an electronic health records environment and also provide disease descriptive characteristics (eg, causal properties, functional impact, and treatment). The threat to the comparability of international clinical morbidity is growing with the development of many country-specific ICD-10 versions. One solution to this threat is to develop a meta-database including all country-specific modifications to ensure more efficient use of people and resources, decrease omissions and errors but most importantly provide a platform for future ICD updates.

  3. The Italian subcutaneous implantable cardioverter-defibrillator survey: S-ICD, why not?

    PubMed

    Botto, Giovanni Luca; Forleo, Giovanni B; Capucci, Alessandro; Solimene, Francesco; Vado, Antonello; Bertero, Giovanni; Palmisano, Pietro; Pisanò, Ennio; Rapacciuolo, Antonio; Infusino, Tommaso; Vicentini, Alessandro; Viscusi, Miguel; Ferrari, Paola; Talarico, Antonello; Russo, Giovanni; Boriani, Giuseppe; Padeletti, Luigi; Lovecchio, Mariolina; Valsecchi, Sergio; D'Onofrio, Antonio

    2017-11-01

    A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. The survey 'S-ICD Why Not?' was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  4. Substance use and addictive disorders in DSM-5 and ICD 10 and the draft ICD 11.

    PubMed

    Saunders, John B

    2017-07-01

    The present review compares and contrasts the diagnostic entities and taxonomy of substance use and addictive disorders in the beta draft of the Eleventh Revision of the International Classification of Diseases (ICD 11), which was released in November 2016, and the Fifth Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), which was published in mid-2013. Recently published papers relevant to these two classification systems are examined. New initiatives in diagnosis and assessment including the addictions neuroclinical assessment are noted. The draft ICD 11 retains substance dependence as the 'master diagnosis' in contrast to the broader and heterogeneous concept of substance use disorder in DSM-5 and there is empirical support for the coherence of substance dependence for alcohol, cannabis, and prescribed opioids. Both systems now include gambling disorder in the addictive disorders section, with it being transferred from the impulse control disorders section. The new diagnosis of Internet gaming disorder is included in DSM-5 as a condition for further study, and gaming disorder is grouped with the substance and gambling disorders in the draft ICD 11. Initiatives from the U.S. National Institutes of Health (NIH) are highlighting the importance of capturing the neurobiological phases of the addictive cycle in clinical diagnosis and assessment. Although most of the changes in the draft ICD 11 and DSM-5 are incremental, the contrast between DSM-5 substance use disorder and substance dependence in the draft ICD 11, and the inclusion of gambling disorder and gaming disorder will generate much discussion and research.

  5. A scoping review of ICD-11 adjustment disorder research.

    PubMed

    Kazlauskas, Evaldas; Zelviene, Paulina; Lorenz, Louisa; Quero, Soledad; Maercker, Andreas

    2017-01-01

    Background : Adjustment disorder (AjD) is one of the most used mental disorder diagnoses among mental health professionals. Important revisions of the AjD definition in the 11th edition of the International Classification of Diseases (ICD-11) are proposed. AjD is included in a chapter of disorders specifically associated with stress in ICD-11. Objective : This paper aims to review recent developments in ICD-11 AjD research, and to discuss the available ICD-11 AjD diagnosis validation studies, AjD measures, treatment studies, and outline the future perspectives for AjD research and clinical practice. Methods : In total, 10 empirical studies of AjD ICD-11 were identified and included in this review. We searched for studies in Embase, PubMed, PsycINFO, Scopus, PILOTS, SocINDEX, and via additional search by contacting authors of published empirical studies and reference screening. Results : Review of the studies revealed a lack of validation studies of the ICD-11 AjD symptom structure. AjD validation study findings are ambiguous, and there is still little support for the proposed two symptom structure of AjD for the ICD-11. A self-report AjD measure 'Adjustment Disorder New Module' (ADNM) based on the ICD-11 definition has been developed and used in all 10 reviewed studies. Two self-help interventions have been developed for the ICD-11 AjD, and findings from these studies indicate that self-help low-intensity cognitive-behavioural interventions, delivered via bibliography or internet-based, might be effective treatment of AjD. Conclusions : The AjD definition in ICD-11 with a description of a new symptom profile facilitates AjD measurement and AjD-focused treatment developments. More studies and insights from clinical practice are needed to move the field of AjD research and practice forward.

  6. Association of Single vs. Dual Chamber ICDs with Mortality, Readmissions and Complications among Patients Receiving an ICD for Primary Prevention

    PubMed Central

    Peterson, Pamela N; Varosy, Paul D; Heidenreich, Paul A; Wang, Yongfei; Dewland, Thomas A; Curtis, Jeptha P; Go, Alan S; Greenlee, Robert T; Magid, David J; Normand, Sharon-Lise T; Masoudi, Frederick A

    2013-01-01

    Importance Randomized trials of implantable cardioverter defibrillators (ICDs) for primary prevention predominantly employed single chamber devices. In clinical practice, patients often receive dual chamber ICDs, even without clear indications for pacing. The outcomes of dual versus single chamber devices are uncertain. Objective Compare outcomes of single and dual chamber ICDs for primary prevention of sudden cardiac death. Design, Setting, and Participants Retrospective cohort study. Admissions in the National Cardiovascular Data Registry’s (NCDR®) ICD Registry™ from 2006–2009 that could be linked to CMS fee for service Medicare claims data were identified. Patients were included if they received an ICD for primary prevention and did not have a documented indication for pacing. Main Outcome Measures Adjusted risks of 1-year mortality, all-cause readmission, HF readmission and device-related complications within 90 days were estimated with propensity-score matching based on patient, clinician and hospital factors. Results Among 32,034 patients, 38% (n=12,246) received a single chamber device and 62% (n=19,788) received a dual chamber device. In a propensity-matched cohort, rates of complications were lower for single chamber devices (3.5% vs. 4.7%; p<0.001; risk difference −1.20; 95% CI −1.72, −0.69), but device type was not significantly associated with mortality or hospitalization outcomes (unadjusted rate 9.9% vs. 9.8%; HR 0.99, 95% CI 0.91–1.07; p=0.792 for 1-year mortality; unadjusted rate 43.9% vs. 44.8%; HR 1.00, 95% CI 0.97–1.04; p=0.821 for 1-year all-cause hospitalization; unadjusted rate 14.7% vs. 15.4%; HR 1.05, 95% CI 0.99–1.12; p=0.189 for 1-year HF hospitalization). Conclusions and Relevance Among patients receiving an ICD for primary prevention without indications for pacing, the use of a dual chamber device compared with a single chamber device was associated with a higher risk of device-related complications but not with

  7. Validating malignant melanoma ICD-9-CM codes in Umbria, ASL Napoli 3 Sud and Friuli Venezia Giulia administrative healthcare databases: a diagnostic accuracy study

    PubMed Central

    Orso, Massimiliano; Serraino, Diego; Fusco, Mario; Giovannini, Gianni; Casucci, Paola; Cozzolino, Francesco; Granata, Annalisa; Gobbato, Michele; Stracci, Fabrizio; Ciullo, Valerio; Vitale, Maria Francesca; Orlandi, Walter; Montedori, Alessandro; Bidoli, Ettore

    2018-01-01

    Objectives To assess the accuracy of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes in identifying subjects with melanoma. Design A diagnostic accuracy study comparing melanoma ICD-9-CM codes (index test) with medical chart (reference standard). Case ascertainment was based on neoplastic lesion of the skin and a histological diagnosis from a primary or metastatic site positive for melanoma. Setting Administrative databases from Umbria Region, Azienda Sanitaria Locale (ASL) Napoli 3 Sud (NA) and Friuli Venezia Giulia (FVG) Region. Participants 112, 130 and 130 cases (subjects with melanoma) were randomly selected from Umbria, NA and FVG, respectively; 94 non-cases (subjects without melanoma) were randomly selected from each unit. Outcome measures Sensitivity and specificity for ICD-9-CM code 172.x located in primary position. Results The most common melanoma subtype was malignant melanoma of skin of trunk, except scrotum (ICD-9-CM code: 172.5), followed by malignant melanoma of skin of lower limb, including hip (ICD-9-CM code: 172.7). The mean age of the patients ranged from 60 to 61 years. Most of the diagnoses were performed in surgical departments. The sensitivities were 100% (95% CI 96% to 100%) for Umbria, 99% (95% CI 94% to 100%) for NA and 98% (95% CI 93% to 100%) for FVG. The specificities were 88% (95% CI 80% to 93%) for Umbria, 77% (95% CI 69% to 85%) for NA and 79% (95% CI 71% to 86%) for FVG. Conclusions The case definition for melanoma based on clinical or instrumental diagnosis, confirmed by histological examination, showed excellent sensitivities and good specificities in the three operative units. Administrative databases from the three operative units can be used for epidemiological and outcome research of melanoma. PMID:29678984

  8. Validating malignant melanoma ICD-9-CM codes in Umbria, ASL Napoli 3 Sud and Friuli Venezia Giulia administrative healthcare databases: a diagnostic accuracy study.

    PubMed

    Orso, Massimiliano; Serraino, Diego; Abraha, Iosief; Fusco, Mario; Giovannini, Gianni; Casucci, Paola; Cozzolino, Francesco; Granata, Annalisa; Gobbato, Michele; Stracci, Fabrizio; Ciullo, Valerio; Vitale, Maria Francesca; Eusebi, Paolo; Orlandi, Walter; Montedori, Alessandro; Bidoli, Ettore

    2018-04-20

    To assess the accuracy of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes in identifying subjects with melanoma. A diagnostic accuracy study comparing melanoma ICD-9-CM codes (index test) with medical chart (reference standard). Case ascertainment was based on neoplastic lesion of the skin and a histological diagnosis from a primary or metastatic site positive for melanoma. Administrative databases from Umbria Region, Azienda Sanitaria Locale (ASL) Napoli 3 Sud (NA) and Friuli Venezia Giulia (FVG) Region. 112, 130 and 130 cases (subjects with melanoma) were randomly selected from Umbria, NA and FVG, respectively; 94 non-cases (subjects without melanoma) were randomly selected from each unit. Sensitivity and specificity for ICD-9-CM code 172.x located in primary position. The most common melanoma subtype was malignant melanoma of skin of trunk, except scrotum (ICD-9-CM code: 172.5), followed by malignant melanoma of skin of lower limb, including hip (ICD-9-CM code: 172.7). The mean age of the patients ranged from 60 to 61 years. Most of the diagnoses were performed in surgical departments.The sensitivities were 100% (95% CI 96% to 100%) for Umbria, 99% (95% CI 94% to 100%) for NA and 98% (95% CI 93% to 100%) for FVG. The specificities were 88% (95% CI 80% to 93%) for Umbria, 77% (95% CI 69% to 85%) for NA and 79% (95% CI 71% to 86%) for FVG. The case definition for melanoma based on clinical or instrumental diagnosis, confirmed by histological examination, showed excellent sensitivities and good specificities in the three operative units. Administrative databases from the three operative units can be used for epidemiological and outcome research of melanoma. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Preparing your organization's training program for ICD-10.

    PubMed

    Carolan, Katie; Reitzel, David

    2011-10-01

    Training for ICD-10 is going to be expensive, though predictions of how expensive vary widely. Healthcare finance executives should create a flexible, multiyear capital and operating budget to prepare for ICD-10 conversion and the training and support that will be required. Healthcare organizations also should assess staff knowledge in the critical ICD-10 areas and begin training now to be ready for go-live by early 2013.

  10. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study

    PubMed Central

    Weems, Shelley; Heller, Pamela; Fenton, Susan H.

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity.Coder training and type of record (inpatient versus outpatient) affect coding productivity.Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity. PMID:26396553

  11. Dollars and sense: Mitigating budget risk for ICD-10.

    PubMed

    Newell, Lucy Mancini; DeSilva, Joseph J

    2013-02-01

    The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.

  12. Acute evaluation of transthoracic impedance vectors using ICD leads.

    PubMed

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  13. The subcutaneous ICD as an alternative to the conventional ICD system: Initial experience in Greece and a review of the literature.

    PubMed

    Sideris, Skevos; Archontakis, Stefanos; Gatzoulis, Konstantinos A; Anastasakis, Aristotelis; Sotiropoulos, Ilias; Arsenos, Petros; Kasiakogias, Alexandros; Terentes, Dimitrios; Trachanas, Konstantinos; Paschalidis, Eleftherios; Tousoulis, Dimitrios; Kallikazaros, Ioannis

    The introduction of an implantable cardioverter defibrillator (ICD) in clinical practice has revolutionized our therapeutic approach for both primary and secondary prevention of sudden cardiac death (SCD), as it has proven to be superior to medical therapy in treating potentially life-threatening ventricular arrhythmias and has resulted in reduced mortality rates. However, implantation of a conventional ICD carries a non-negligible risk of periprocedural and long-term complications associated with the transvenous ICD leads. The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) has recently emerged as a therapeutic alternative to the conventional ICD for patients with various cardiopathies and who are at high risk of SCD. The main advantage is the avoidance of vascular access and thus avoidance of complications associated with transvenous leads. Patients without pacing indications, such as bradycardia, a need for antitachycardia pacing or cardiac resynchronization, as well as those at higher risk of complications from transvenous lead implantation are perfect candidates for this novel technology. The subcutaneous ICD has proven to be equally safe and effective compared to transvenous ICD systems in early clinical trials. Further technical improvements of the system will likely lead to the expansion of indications and widespread use of this technology. In the present review, we discuss the indications for this system, summarize early clinical experiences and highlight the advantages and disadvantages of this novel technology. In addition, we present the first two cases of subcutaneous cardioverter defibrillator system implantation in Greece. Copyright © 2017 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.

  14. Predicting trauma patient mortality: ICD [or ICD-10-AM] versus AIS based approaches.

    PubMed

    Willis, Cameron D; Gabbe, Belinda J; Jolley, Damien; Harrison, James E; Cameron, Peter A

    2010-11-01

    The International Classification of Diseases Injury Severity Score (ICISS) has been proposed as an International Classification of Diseases (ICD)-10-based alternative to mortality prediction tools that use Abbreviated Injury Scale (AIS) data, including the Trauma and Injury Severity Score (TRISS). To date, studies have not examined the performance of ICISS using Australian trauma registry data. This study aimed to compare the performance of ICISS with other mortality prediction tools in an Australian trauma registry. This was a retrospective review of prospectively collected data from the Victorian State Trauma Registry. A training dataset was created for model development and a validation dataset for evaluation. The multiplicative ICISS model was compared with a worst injury ICISS approach, Victorian TRISS (V-TRISS, using local coefficients), maximum AIS severity and a multivariable model including ICD-10-AM codes as predictors. Models were investigated for discrimination (C-statistic) and calibration (Hosmer-Lemeshow statistic). The multivariable approach had the highest level of discrimination (C-statistic 0.90) and calibration (H-L 7.65, P= 0.468). Worst injury ICISS, V-TRISS and maximum AIS had similar performance. The multiplicative ICISS produced the lowest level of discrimination (C-statistic 0.80) and poorest calibration (H-L 50.23, P < 0.001). The performance of ICISS may be affected by the data used to develop estimates, the ICD version employed, the methods for deriving estimates and the inclusion of covariates. In this analysis, a multivariable approach using ICD-10-AM codes was the best-performing method. A multivariable ICISS approach may therefore be a useful alternative to AIS-based methods and may have comparable predictive performance to locally derived TRISS models. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.

  15. 76 FR 51985 - ICD-9-CM Coordination and Maintenance Committee Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ... and Public Health Data Standards Staff, announces the following meeting. Name: ICD-9-CM Coordination.... 2012 ICD-10-PCS GEM and Reimbursement Map Updates. ICD-10-PCS Official Coding Guidelines. ICD-10 MS... Pickett, Medical Systems Administrator, Classifications and Public Health Data Standards Staff, NCHS, 3311...

  16. Patient satisfaction and suggestions for improvement of remote ICD monitoring.

    PubMed

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe; Kensing, Finn; Svendsen, Jesper Hastrup

    2012-09-01

    The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients' wish for changes in remote follow-up routines. Four hundred seventy-four ICD patients at the device follow-up clinic at Rigshospitalet using CareLink® (Medtronic) remote follow-up, who had made ≥2 transmissions, received a questionnaire. Three hundred eighty-five patients (81.2%) answered. Mean time with ICD was 56 ± 45 months and mean age was 62 ± 13 years; 80% was male. Diagnosis related to ICD implant was: ischemic heart disease in 56% and dilated cardiomyopathy in 21%. Twenty-six percent had primary prophylactic indication. Mean time on remote FU was 16.4 ± 6.9 months. Mean time spent on in-clinic FU (two-way transport and FU) was 4 h and 36 min ± 7 h and 50 min, excluding 12 patients from Greenland and Faroe Islands. Ninety-five percent of the patients was very content or content with remote FU compared to in-clinic FU; 3% was less content and 2% was not content. For scheduled transmissions, 21% of the patients wished for a faster reply (sms or e-mail) compared to current practice with a letter. Eighty-four percent preferred more detailed information concerning ICD leads, battery status, and ICD therapies. A total of 96 patients (25%) had performed extra unscheduled remote transmissions: 20 due to shock, 20 due to alarm, 35 due to palpitations, and 18 for other or combined reasons. Ninety-five percent of the patients were content with the remote FU. Only 25% had unscheduled transmissions and most unscheduled transmissions were for appropriate reasons. Eighty-four percent of the patients wished for a more detailed response and 21% wished for a faster reply after routine transmissions.

  17. Hypochondriasis: considerations for ICD-11.

    PubMed

    van den Heuvel, Odile A; Veale, David; Stein, Dan J

    2014-01-01

    The World Health Organization (WHO) is currently revisiting the ICD. In the 10th version of the ICD, approved in 1990, hypochondriacal symptoms are described in the context of both the primary condition hypochondriacal disorder and as secondary symptoms within a range of other mental disorders. Expansion of the research base since 1990 makes a critical evaluation and revision of both the definition and classification of hypochondriacal disorder timely. This article addresses the considerations reviewed by members of the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders in their proposal for the description and classification of hypochondriasis. The proposed revision emphasizes the phenomenological overlap with both anxiety disorders (e.g., fear, hypervigilance to bodily symptoms, and avoidance) and obsessive-compulsive and related disorders (e.g., preoccupation and repetitive behaviors) and the distinction from the somatoform disorders (presence of somatic symptom is not a critical characteristic). This revision aims to improve clinical utility by enabling better recognition and treatment of patients with hypochondriasis within the broad range of global health care settings.

  18. [Inappropriate ICD therapies: All problems solved with MADIT-RIT?].

    PubMed

    Kolb, Christof

    2015-06-01

    The MADIT-RIT study represents a major trial in implantable cardioverter-defibrillator (ICD) therapy that was recently published. It highlights that different programming strategies (high rate cut-off or delayed therapy versus conventional) reduce inappropriate ICD therapies, leave syncope rates unaltered and can improve patient's survival. The study should motivate cardiologist and electrophysiologists to reconsider their individual programming strategies. However, as the study represents largely patients with ischemic or dilated cardiomyopathy for primary prevention of sudden cardiac death supplied with a dual chamber or cardiac resynchronisation therapy ICD, the results may not easily be transferable to other entities or other device types. Despite the success of the MADIT-RIT study efforts still need to be taken to further optimise device algorithms to avert inappropriate therapies. Optimised ICD therapy also includes the avoidance of unnecessary ICD shocks as well as the treatment of all aspects of the underlying cardiac disease.

  19. Implementation and impact of ICD-10 (Part II)

    PubMed Central

    Rahmathulla, Gazanfar; Deen, H. Gordon; Dokken, Judith A.; Pirris, Stephen M.; Pichelmann, Mark A.; Nottmeier, Eric W.; Reimer, Ronald; Wharen, Robert E.

    2014-01-01

    Background: The transition from the International Classification of Disease-9th clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. Methods: The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. Results: The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. Conclusion: With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices. PMID:25184098

  20. Implementation and impact of ICD-10 (Part II).

    PubMed

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    The transition from the International Classification of Disease-9(th) clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices.

  1. Validation of ICD-9-CM coding algorithm for improved identification of hypoglycemia visits.

    PubMed

    Ginde, Adit A; Blanc, Phillip G; Lieberman, Rebecca M; Camargo, Carlos A

    2008-04-01

    Accurate identification of hypoglycemia cases by International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes will help to describe epidemiology, monitor trends, and propose interventions for this important complication in patients with diabetes. Prior hypoglycemia studies utilized incomplete search strategies and may be methodologically flawed. We sought to validate a new ICD-9-CM coding algorithm for accurate identification of hypoglycemia visits. This was a multicenter, retrospective cohort study using a structured medical record review at three academic emergency departments from July 1, 2005 to June 30, 2006. We prospectively derived a coding algorithm to identify hypoglycemia visits using ICD-9-CM codes (250.3, 250.8, 251.0, 251.1, 251.2, 270.3, 775.0, 775.6, and 962.3). We confirmed hypoglycemia cases by chart review identified by candidate ICD-9-CM codes during the study period. The case definition for hypoglycemia was documented blood glucose 3.9 mmol/l or emergency physician charted diagnosis of hypoglycemia. We evaluated individual components and calculated the positive predictive value. We reviewed 636 charts identified by the candidate ICD-9-CM codes and confirmed 436 (64%) cases of hypoglycemia by chart review. Diabetes with other specified manifestations (250.8), often excluded in prior hypoglycemia analyses, identified 83% of hypoglycemia visits, and unspecified hypoglycemia (251.2) identified 13% of hypoglycemia visits. The absence of any predetermined co-diagnosis codes improved the positive predictive value of code 250.8 from 62% to 92%, while excluding only 10 (2%) true hypoglycemia visits. Although prior analyses included only the first-listed ICD-9 code, more than one-quarter of identified hypoglycemia visits were outside this primary diagnosis field. Overall, the proposed algorithm had 89% positive predictive value (95% confidence interval, 86-92) for detecting hypoglycemia visits. The proposed algorithm

  2. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples

    PubMed Central

    Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask

    2015-01-01

    Background In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. Objectives and method The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. Results The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. Conclusions The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria. PMID:26450830

  3. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples.

    PubMed

    Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask

    2015-01-01

    In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria.

  4. Introducing ICD-resistant mortality as an end point to evaluate the clinical efficacy of an implantable cardioverter-defibrillator in ischaemic cardiomyopathy.

    PubMed

    Floré, Vincent; Vandenberk, Bert; Belmans, Ann; Garweg, Christophe; Ector, Joris; Willems, Rik

    2018-02-01

    A new end point called ICD-resistant mortality was evaluated to assess the clinical efficacy of ICD implantations. In 302 ICD patients with ischaemic cardiomyopathy, we investigated which clinical parameters predicted useful ICD implantations using cumulative incidence competing risk analysis. Implantation was deemed clinically useful when the ICD provided appropriate therapy and the patient survived implantation by 1 year and the first shock by 30 days. ICD-resistant mortality (ICDRM) was defined as death within 30 days after the first shock, within 1 year of implantation or without previous appropriate ICD therapy. After 5 years, ICDRM occurred in 23% of implantations, while 36% were clinically useful. After multivariable analysis, ICDRM was associated with LVEF <35% (HR: 2.63; p = .005), beta-blocker dose <50% (HR: 2.0; p = .01) and anterior or diffuse infarct location (HR: 3.61; p = .001 and HR: 2.89; p = .02). Useful ICD implantations were associated with beta-blocker dose <50% (HR: 1.64; p = .02) and non-anterior infarct location (HR: 3.22 vs anterior and 1.59 vs diffuse; combined p<.001). Five years after implantation, an ICD could be classified as useful in 1 out of 3, while ICDRM occurred in one out of four patients. At 10 years, up to 80% of implantations could be categorized. Lower LVEF was related with significantly higher incidence of ICDRM. Anterior infarcts were associated with more ICDRM and less useful implantations than non-anterior infarcts. Future risk stratification for ICD should focus more on the discrimination between arrhythmic risk, probably preventable by ICDs and ICD-resistant mortality risk.

  5. Effect of supplemented intake of omega-3 fatty acids on arrhythmias in patients with ICD: fish oil therapy may reduce ventricular arrhythmia.

    PubMed

    Weisman, Dalit; Beinart, Roy; Erez, Aharon; Koren-Morag, Nira; Goldenberg, Ilan; Eldar, Michael; Glikson, Michael; Luria, David

    2017-09-01

    The aim of this study was to evaluate the effects of fish oils, including eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), on ventricular tachyarrhythmic episodes (VTEs) in implantable cardioverter defibrillator (ICD) recipients with ischemic cardiomyopathy. One hundred five ICD recipients with ischemic cardiomyopathy received 3.6 g of EPA and DHA and placebo for 6 months, each at a random order, with a 4-month washout period between treatments. Eighty-seven patients completed the 16-month study protocol. The primary end point was any VTE (including sustained and non-sustained ventricular tachycardias at a rate of >150 bpm) as recorded by the ICDs. Secondary end points included device therapy (anti-tachycardia pacing (ATP) or shocks). During treatment with fish oils, there was a significant increase in EPA and DHA concentrations in red blood cells (RBCs) and subcutaneous fat tissue. Among 87 patients who completed the study protocol, the mean number of VTEs was significantly lower during treatment with fish oil (1.7) vs. placebo (5.6; p = 0.035). Appropriate device therapy for VTE occurred in 18 (21%) patients. Fish oil therapy was associated with a trend toward fewer VTEs terminated with ATP (2.8 ± 13.7 vs. 0.5 ± 2.1, respectively; p = 0.077). VTE terminated by ICD shocks, however, was rare, and rates were similar between both groups (0.11 ± 0.6 vs. 0.10 ± 0.4, p = not significant, respectively). Our data suggest that fish oil therapy may be associated with a reduction in the frequency of VTE in ICD recipients with ischemic cardiomyopathy.

  6. Implementation of ICD-10 in Canada: how has it impacted coded hospital discharge data?

    PubMed Central

    2012-01-01

    Background The purpose of this study was to assess whether or not the change in coding classification had an impact on diagnosis and comorbidity coding in hospital discharge data across Canadian provinces. Methods This study examined eight years (fiscal years 1998 to 2005) of hospital records from the Hospital Person-Oriented Information database (HPOI) derived from the Canadian national Discharge Abstract Database. The average number of coded diagnoses per hospital visit was examined from 1998 to 2005 for provinces that switched from International Classifications of Disease 9th version (ICD-9-CM) to ICD-10-CA during this period. The average numbers of type 2 and 3 diagnoses were also described. The prevalence of the Charlson comorbidities and distribution of the Charlson score one year before and one year after ICD-10 implementation for each of the 9 provinces was examined. The prevalence of at least one of the seventeen Charlson comorbidities one year before and one year after ICD-10 implementation were described by hospital characteristics (teaching/non-teaching, urban/rural, volume of patients). Results Nine Canadian provinces switched from ICD-9-CM to ICD-I0-CA over a 6 year period starting in 2001. The average number of diagnoses coded per hospital visit for all code types over the study period was 2.58. After implementation of ICD-10-CA a decrease in the number of diagnoses coded was found in four provinces whereas the number of diagnoses coded in the other five provinces remained similar. The prevalence of at least one of the seventeen Charlson conditions remained relatively stable after ICD-10 was implemented, as did the distribution of the Charlson score. When stratified by hospital characteristics, the prevalence of at least one Charlson condition decreased after ICD-10-CA implementation, particularly for low volume hospitals. Conclusion In conclusion, implementation of ICD-10-CA in Canadian provinces did not substantially change coding practices, but

  7. Uncommon combinations of ICD10-PCS or ICD-9-CM operative procedure codes account for most inpatient surgery at half of Texas hospitals.

    PubMed

    O'Neill, Liam; Dexter, Franklin; Park, Sae-Hwan; Epstein, Richard H

    2017-09-01

    Recently, there has been interest in activity-based cost accounting for inpatient surgical procedures to facilitate "value based" analyses. Research 10-20years ago, performed using data from 3 large teaching hospitals, found that activity-based cost accounting was practical and useful for modeling surgeons and subspecialties, but inaccurate for individual procedures. We hypothesized that these older results would apply to hundreds of hospitals, currently evaluable using administrative databases. Observational study. State of Texas hospital discharge abstract data for 1st quarter of 2016, 4th quarter of 2015, 1st quarter of 2015, and 4th quarter of 2014. Discharged from an acute care hospital in Texas with at least 1 major therapeutic ("operative") procedure. Counts of discharges for each procedure or combination of procedures, classified by ICD-10-PCS or ICD-9-CM. At the average hospital, most surgical discharges were for procedures performed at most once a month at the hospital (54%, 95% confidence interval [CI] 51% to 55%). At the average hospital, approximately 90% of procedures were performed at most once a month at the hospital (93%, CI 93% to 94%). The percentages were insensitive to the quarter of the year. The percentages were 3% to 6% greater with ICD-10-PCS than for the superseded ICD 9 CM. There are many different procedure codes, and many different combinations of codes, relative to the number of different hospital discharges. Since most procedures at most hospitals are performed no more than once a month, activity-based cost accounting with a sample size sufficient to be useful is impractical for the vast majority of procedures, in contrast to analysis by surgeon and/or subspecialty. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Inappropriate ICD discharges due to "triple counting" during normal sinus rhythm.

    PubMed

    Khan, Ejaz; Voudouris, Apostolos; Shorofsky, Stephen R; Peters, Robert W

    2006-11-01

    To describe the clinical course of a patient with multiple ICD shocks in the setting of advanced renal failure and hyperkalemia. The patient was brought to the Electrophysiology Laboratory where the ICD was interrogated. The patient was found to be hyperkalemic (serum potassium 7.6 mg/dl). Analysis of stored intracardiac electrograms from the ICD revealed "triple counting" (twice during his QRS complex and once during the T wave) and multiple inappropriate shocks. Correction of his electrolyte abnormality normalized his electrogram and no further ICD activations were observed. Electrolyte abnormalities can distort the intracardiac electrogram in patients with ICD's and these changes can lead to multiple inappropriate shocks.

  9. Validating the Use of ICD-9 Code Mapping to Generate Injury Severity Scores

    PubMed Central

    Fleischman, Ross J.; Mann, N. Clay; Dai, Mengtao; Holmes, James F.; Wang, N. Ewen; Haukoos, Jason; Hsia, Renee Y.; Rea, Thomas; Newgard, Craig D.

    2017-01-01

    The Injury Severity Score (ISS) is a measure of injury severity widely used for research and quality assurance in trauma. Calculation of ISS requires chart abstraction, so it is often unavailable for patients cared for in nontrauma centers. Whether ISS can be accurately calculated from International Classification of Diseases, Ninth Revision (ICD-9) codes remains unclear. Our objective was to compare ISS derived from ICD-9 codes with those coded by trauma registrars. This was a retrospective study of patients entered into 9 U.S. trauma registries from January 2006 through December 2008. Two computer programs, ICDPIC and ICDMAP, were used to derive ISS from the ICD-9 codes in the registries. We compared derived ISS with ISS hand-coded by trained coders. There were 24,804 cases with a mortality rate of 3.9%. The median ISS derived by both ICDPIC (ISS-ICDPIC) and ICDMAP (ISS-ICDMAP) was 8 (interquartile range [IQR] = 4–13). The median ISS in the registry (ISS-registry) was 9 (IQR = 4–14). The median difference between either of the derived scores and ISS-registry was zero. However, the mean ISS derived by ICD-9 code mapping was lower than the hand-coded ISS in the registries (1.7 lower for ICDPIC, 95% CI [1.7, 1.8], Bland–Altman limits of agreement = −10.5 to 13.9; 1.8 lower for ICDMAP, 95% CI [1.7, 1.9], limits of agreement = −9.6 to 13.3). ICD-9-derived ISS slightly underestimated ISS compared with hand-coded scores. The 2 methods showed moderate to substantial agreement. Although hand-coded scores should be used when possible, ICD-9-derived scores may be useful in quality assurance and research when hand-coded scores are unavailable. PMID:28033134

  10. Piloting a Collaborative Web-Based System for Testing ICD-11.

    PubMed

    Donada, Marc; Kostanjsek, Nenad; Della Mea, Vincenzo; Celik, Can; Jakob, Robert

    2017-01-01

    The 11th revision of the International Classification of Diseases (ICD-11), for the first time in ICD history, deployed web-based collaboration of experts and ICT tools. To ensure that ICD-11 is working well, it needs to be systematically field tested in different settings, across the world. This will be done by means of a number of experiments. In order to support its implementation, a web-based system (ICDfit) has been designed and developed. The present paper illustrates the current prototype of the system and its technical testing. the system has been designed according to WHO requirements, and implemented using PHP and MySQL. Then, a preliminary technical test has been designed and run in January 2016, involving 8 users. They had to carry out double coding, that is, coding case summaries with both ICD-10 and ICD-11, and answering quick questions on the coding difficulty. the 8 users coded 632 cases each, spending an average of 163 seconds per case. While we found an issue in the mechanism used to record coding times, no further issues were found. the proposed system seems to be technically adequate for supporting future ICD-11 testing.

  11. Optimal programming management of ventricular tachycardia storm in ICD patients

    PubMed Central

    Qian, Zhiyong; Guo, Jianghong; Zhang, Zhiyong; Wang, Yao; Hou, Xiaofeng; Zou, Jiangang

    2015-01-01

    Abstract Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter defibrillator (ICD) therapy within 24 hours. Patients with VTS have poor outcomes and require immediate medical attention. ICD shocks have been shown to be associated with increased mortality in several studies. Optimal programming in minimization of ICD shocks may decrease mortality. Large controlled trials showed that long detection time and high heart rate detection threshold reduced ICD shock burden without an increase in syncope or death. As a fundamental therapy of ICD, antitachycardia pacing (ATP) can terminate most slow VT with a low risk of acceleration. For fast VT, burst pacing is more effective and less likely to result in acceleration than ramp pacing. One algorithm of optimal programming management during a VTS is presented in the review. PMID:25745473

  12. Predicting in-hospital mortality of traffic victims: A comparison between AIS-and ICD-9-CM-related injury severity scales when only ICD-9-CM is reported.

    PubMed

    Van Belleghem, Griet; Devos, Stefanie; De Wit, Liesbet; Hubloue, Ives; Lauwaert, Door; Pien, Karen; Putman, Koen

    2016-01-01

    Injury severity scores are important in the context of developing European and national goals on traffic safety, health-care benchmarking and improving patient communication. Various severity scores are available and are mostly based on Abbreviated Injury Scale (AIS) or International Classification of Diseases (ICD). The aim of this paper is to compare the predictive value for in-hospital mortality between the various severity scores if only International Classification of Diseases, 9th revision, Clinical Modification ICD-9-CM is reported. To estimate severity scores based on the AIS lexicon, ICD-9-CM codes were converted with ICD Programmes for Injury Categorization (ICDPIC) and four AIS-based severity scores were derived: Maximum AIS (MaxAIS), Injury Severity Score (ISS), New Injury Severity Score (NISS) and Exponential Injury Severity Score (EISS). Based on ICD-9-CM, six severity scores were calculated. Determined by the number of injuries taken into account and the means by which survival risk ratios (SRRs) were calculated, four different approaches were used to calculate the ICD-9-based Injury Severity Scores (ICISS). The Trauma Mortality Prediction Model (TMPM) was calculated with the ICD-9-CM-based model averaged regression coefficients (MARC) for both the single worst injury and multiple injuries. Severity scores were compared via model discrimination and calibration. Model comparisons were performed separately for the severity scores based on the single worst injury and multiple injuries. For ICD-9-based scales, estimation of area under the receiver operating characteristic curve (AUROC) ranges between 0.94 and 0.96, while AIS-based scales range between 0.72 and 0.76, respectively. The intercept in the calibration plots is not significantly different from 0 for MaxAIS, ICISS and TMPM. When only ICD-9-CM codes are reported, ICD-9-CM-based severity scores perform better than severity scores based on the conversion to AIS. Copyright © 2015 Elsevier Ltd. All

  13. Reconstruction of an 8-lead surface ECG from two subcutaneous ICD vectors.

    PubMed

    Wilson, David G; Cronbach, Peter L; Panfilo, D; Greenhut, Saul E; Stegemann, Berthold P; Morgan, John M

    2017-06-01

    Techniques exist which allow surface ECGs to be reconstructed from reduced lead sets. We aimed to reconstruct an 8-lead ECG from two independent S-ICD sensing electrodes vectors as proof of this principle. Participants with ICDs (N=61) underwent 3minute ECGs using a TMSi Porti7 multi-channel signal recorder (TMS international, The Netherlands) with electrodes in the standard S-ICD and 12-lead positions. Participants were randomised to either a training (N=31) or validation (N=30) group. The transformation used was a linear combination of the 2 independent S-ICD vectors to each of the 8 independent leads of the 12-lead ECG, with coefficients selected that minimized the root mean square error (RMSE) between recorded and derived ECGs when applied to the training group. The transformation was then applied to the validation group and agreement between the recorded and derived lead pairs was measured by Pearson correlation coefficient (r) and normalised RMSE (NRMSE). In total, 27 patients with complete data sets were included in the validation set consisting of 57,888 data points from 216 full lead sets. The distribution of the r and NRMSE were skewed. Mean r=0.770 (SE 0.024), median r=0.925. NRMSE mean=0.233 (SE 0.015) median=0.171. We have demonstrated that the reconstruction of an 8-lead ECG from two S-ICD vectors is possible. If perfected, the ability to generate accurate multi-lead surface ECG data from an S-ICD would potentially allow recording and review of clinical arrhythmias at follow-up. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Identification of ICD Codes Suggestive of Child Maltreatment

    ERIC Educational Resources Information Center

    Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.

    2011-01-01

    Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…

  15. Diagnostic Concordance between DSM-5 and ICD-10 Cannabis Use Disorders.

    PubMed

    Proctor, Steven L; Williams, Daniel C; Kopak, Albert M; Voluse, Andrew C; Connolly, Kevin M; Hoffmann, Norman G

    2016-07-01

    With the recent federal mandate that all U.S. health care settings transition to ICD-10 billing codes, empirical evidence is necessary to determine if the DSM-5 designations map to their respective ICD-10 diagnostic categories/billing codes. The present study examined the concordance between DSM-5 and ICD-10 cannabis use disorder diagnoses. Data were derived from routine clinical assessments of 6871 male and 801 female inmates recently admitted to a state prison system from 2000 to 2003. DSM-5 and ICD-10 diagnostic determinations were made from algorithms corresponding to the respective diagnostic formulations. Past 12-month prevalence rates of cannabis use disorders were comparable across classification systems. The vast majority of inmates with no DSM-5 diagnosis continued to have no diagnosis per the ICD-10, and a similar proportion with a DSM-5 severe diagnosis received an ICD-10 dependence diagnosis. Most of the variation in diagnostic classifications was accounted for by those with a DSM-5 moderate diagnosis in that approximately half of these cases received an ICD-10 dependence diagnosis while the remaining cases received a harmful use diagnosis. Although there appears to be a generally high level of agreement between diagnostic classification systems for those with no diagnosis or those evincing symptoms of a more severe condition, concordance between DSM-5 moderate and ICD-10 dependence diagnoses was poor. Additional research is warranted to determine the appropriateness and implications of the current DSM-5 coding guidelines regarding the assignment of an ICD-10 dependence code for those with a DSM-5 moderate diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Minding the body: situating gender identity diagnoses in the ICD-11.

    PubMed

    Drescher, Jack; Cohen-Kettenis, Peggy; Winter, Sam

    2012-12-01

    The World Health Organization (WHO) is in the process of revising the International Statistical Classification of Diseases and Related Health Problems (ICD) and ICD-11 has an anticipated publication date of 2015. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH) is charged with evaluating clinical and research data to inform the revision of diagnostic categories related to sexuality and gender identity that are currently included in the mental and behavioural disorders chapter of ICD-10, and making initial recommendations regarding whether and how these categories should be represented in the ICD-11. The diagnostic classification of disorders related to (trans)gender identity is an area long characterized by lack of knowledge, misconceptions and controversy. The placement of these categories has shifted over time within both the ICD and the American Psychiatric Association's Diagnostic and Statistical Manual (DSM), reflecting developing views about what to call these diagnoses, what they mean and where to place them. This article reviews several controversies generated by gender identity diagnoses in recent years. In both the ICD-11 and DSM-5 development processes, one challenge has been to find a balance between concerns related to the stigmatization of mental disorders and the need for diagnostic categories that facilitate access to healthcare. In this connection, this article discusses several human rights issues related to gender identity diagnoses, and explores the question of whether affected populations are best served by placement of these categories within the mental disorders section of the classification. The combined stigmatization of being transgender and of having a mental disorder diagnosis creates a doubly burdensome situation for this group, which may contribute adversely to health status and to the attainment and enjoyment of human rights. The ICD-11 Working Group on the Classification of Sexual Disorders and

  17. Atmospheric, Magnetospheric and Plasmas in Space (AMPS) spacelab payload definition study. Volume 3: Interface control documents. Part 2: AMPS payload to spacelab ICD

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The AMPS to Spacelab Interface Control Document which is to be used as a guide for format and information content in generating specific AMPS Mission ICDs is presented. This document is meant to supplement the Spacelab Payload Accommodations Handbook in that it only defines interfaces which are not discussed in the handbook to the level required for design purposes. The AMPS Top Level Requirements Tree, illustrates this ICD by a shaded area and its relationship to the other AMPS technical documents. Other interface documents shown are the Level II, AMPS to Space Shuttle Vehicle ICD and the Level III, AMPS to Instruments ICD.

  18. Psychosocial impact of implantable cardioverter defibrillators (ICD) in young adults with Tetralogy of Fallot.

    PubMed

    Opić, Petra; Utens, Elisabeth M W J; Moons, Philip; Theuns, Dominic A M J; van Dijk, Arie P J; Hoendermis, Elke S; Vliegen, Hubert W; de Groot, Natasja M S; Witsenburg, Maarten; Schalij, Martin; Roos-Hesselink, Jolien W

    2012-07-01

    To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). Included were 26 ToF-patients with an ICD (age 44 ± 12 years), and two control groups consisting of 28 ToF-patients without an ICD (age 40 ± 10 years) and a group of 35 ICD-patients of older age without ToF (age 72.0 ± 8 years). This last control group was chosen to represent the "older general ICD population" with acquired heart disease seen at the out-patient clinic. Psychosocial functioning encompassed daily functioning, subjective health status, quality of life, anxiety, depression, coping and social support. ToF-patients with ICD showed diminished psychosocial functioning in comparison to ToF-patients without ICD. This was reflected by diminished subjectively perceived physical functioning (p = 0.01), general health perception (p < 0.01) and a lower satisfaction with life (p = 0.02). In comparison to older ICD-patients, ToF-patients with ICD showed less satisfaction with life (p = 0.03), experienced more anxiety (p = 0.01) and showed less favourable coping styles, although physical functioning was better for ToF-patients with ICD than for older ICD-patients (p = 0.01). More inappropriate shocks were found in ToF-patients with ICD compared to the older ICD-patients. In patients with ToF, ICD implantation had a major impact on psychosocial functioning which should be taken into account when considering ICD implantation in these young patients. To help improve psychosocial functioning, psychological counselling attuned to the specific needs of these patients may be useful.

  19. A Strategic Plan for Integrating ICD-10 in Your Practice and Workflow.

    PubMed

    Bowman, Sue; Cleland, Risë Marie; Staggs, Stuart

    2015-01-01

    The adoption of the International Classification of Disease (ICD) 10th Revision (ICD-10) diagnosis code set in the United States has been legislatively delayed several times with the most recent date for implementation set for October 1, 2015. The transition from ICD-9 to ICD-10 will be a major undertaking that will require a substantial amount of planning. In the following article, we outline the steps to develop and implement a strategic plan for the transition to the new code set, identify training needs throughout the practice, and review the challenges and opportunities associated with the transition to ICD-10.

  20. Inadvertent transposition of defibrillator coil terminal pins causing inappropriate ICD therapies.

    PubMed

    Issa, Ziad F

    2008-06-01

    We report the case of a 65-year-old man with chronic atrial fibrillation (AF) and severe ischemic cardiomyopathy who underwent implantation of a prophylactic single-chamber implantable cardioverter-defibrillator (ICD). The patient experienced inappropriate ICD therapies due to oversensing of pectoral muscle myopotential secondary to reversal of the defibrillator coil terminal pins in the ICD header. Recognizing this possibility is important to avoid misinterpretation of spontaneous oversensing as hardware failure (e.g., lead fracture or insulation breech) and potentially unnecessary ICD system surgical intervention, including lead extraction.

  1. Harmonisation of ICD-11 and DSM-V: opportunities and challenges.

    PubMed

    First, Michael B

    2009-11-01

    Differences in the ICD-10 and DSM-IV definitions for the same disorder impede international communication and research efforts. The forthcoming parallel development of DSM-V and ICD-11 offers an opportunity to harmonise the two classifications. This paper aims to facilitate the harmonisation process by identifying diagnostic differences between the two systems. DSM-IV-TR criteria sets and the ICD-10 Diagnostic Criteria for Research were compared and categorised into those with identical definitions, those with conceptually based differences and those in which differences are not conceptually based and appear to be unintentional. Of the 176 criteria sets in both systems, only one, transient tic disorder, is identical. Twenty-one per cent had conceptually based differences and 78% had non-conceptually based differences. Harmonisation of criteria sets, especially those with non-conceptually based differences, should be prioritised in the DSM-V and ICD-11 development process. Prior experience with the DSM-IV and ICD-10 harmonisation effort suggests that for the process to be successful steps should be taken as early as possible.

  2. ICD-10: from assessment to remediation to strategic opportunity.

    PubMed

    Dugan, John K

    2012-02-01

    Healthcare finance teams should perform an enterprisewide assessment to determine what ICD-10 means to their organization, strategically, operationally, and financially. CFOs should strategically evaluate the impact of ICD-10 on the organization's entire financial operation. Organizations should have a contingency plan in place across all processes.

  3. Postmortem ICD interrogation in mode of death classification.

    PubMed

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  4. Clashing Diagnostic Approaches: DSM-ICD versus RDoC

    PubMed Central

    Lilienfeld, Scott O.; Treadway, Michael T.

    2016-01-01

    Since at least the middle of the past century, one overarching model of psychiatric classification, namely, that of the Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases (DSM-ICD), has reigned supreme. This DSM-ICD approach embraces an Aristotelian view of mental disorders as largely discrete entities that are characterized by distinctive signs, symptoms, and natural histories. Over the past several years, however, a competing vision, namely, the Research Domain Criteria (RDoC) initiative launched by the National Institute of Mental Health, has emerged in response to accumulating anomalies within the DSM-ICD system. In contrast to DSM-ICD, RDoC embraces a Galilean view of psychopathology as the product of dysfunctions in neural circuitry. RDoC appears to be a valuable endeavor that holds out the long-term promise of an alternative system of mental illness classification. We delineate three sets of pressing challenges – conceptual, methodological, and logistical/pragmatic – that must be addressed for RDoC to realize its scientific potential, and conclude with a call for further research, including investigation of a rapprochement between Aristotelian and Galilean approaches to psychiatric classification. PMID:26845519

  5. Stereotyped movement disorder in ICD-11.

    PubMed

    Stein, Dan J; Woods, Douglas W

    2014-01-01

    According to current proposals for ICD-11, stereotyped movement disorder will be classified in the grouping of neurodevelopmental disorders, with a qualifier to indicate whether self-injury is present, similar to the classification of stereotypic movement disorder in DSM-5. At the same time, the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders has proposed a grouping of body-focused repetitive behavior disorders within the obsessive-compulsive and related disorders (OCRD) cluster to include trichotillomania and skin-picking disorder. DSM-5 has taken a slightly different approach: trichotillomania and excoriation (skin picking) disorder are included in the OCRD grouping, while body-focused repetitive behavior disorder is listed under other specified forms of OCRD. DSM-5 also includes a separate category of nonsuicidal self-injury in the section on "conditions for further study." There are a number of unresolved nosological questions regarding the relationships among stereotyped movement disorder, body-focused repetitive behavior disorders, and nonsuicidal self-injury. In this article, we attempt to provide preliminary answers to some of these questions as they relate to the ICD-11 classification of mental and behavioral disorders.

  6. Reduction in depressive symptoms in primary prevention ICD scheduled patients - One year prospective study.

    PubMed

    Amiaz, Revital; Asher, Elad; Rozen, Guy; Czerniak, Efrat; Levi, Linda; Weiser, Mark; Glikson, Michael

    2017-09-01

    Implantable Cardioverter Defibrillators (ICDs), have previously been associated with the onset of depression and anxiety. The aim of this one-year prospective study was to evaluate the rate of new onset psychopathological symptoms after elective ICD implantation. A total of 158 consecutive outpatients who were scheduled for an elective ICD implantation were diagnosed and screened based on the Mini International Neuropsychiatric Interview (MINI). Depression and anxiety were evaluated using the Hamilton Rating Scales for Depression (HAM-D) and Anxiety (HAM-A). Patient's attitude toward the ICD device was evaluated using a Visual Analog Scale (VAS). Patients' mean age was 64±12.4years; 134 (85%) were men, with the majority of patients performing the procedure for reasons of 'primary prevention'. According to the MINI diagnosis at baseline, three (2%) patients suffered from major depressive disorder and ten (6%) from dysthymia. Significant improvement in HAM-D mean scores was found between baseline, three months and one year after implantation (6.50±6.4; 4.10±5.3 and 2.7±4.6, respectively F(2100)=16.42; p<0.001). There was a significantly more positive attitude toward the device over time based on the VAS score [F(2122)=53.31, p<0.001]. ICD implantation significantly contributes to the reduction of depressive symptoms, while the overall mindset toward the ICD device was positive and improved during the one-year follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Validation of ICD-9 Codes for Stable Miscarriage in the Emergency Department.

    PubMed

    Quinley, Kelly E; Falck, Ailsa; Kallan, Michael J; Datner, Elizabeth M; Carr, Brendan G; Schreiber, Courtney A

    2015-07-01

    International Classification of Disease, Ninth Revision (ICD-9) diagnosis codes have not been validated for identifying cases of missed abortion where a pregnancy is no longer viable but the cervical os remains closed. Our goal was to assess whether ICD-9 code "632" for missed abortion has high sensitivity and positive predictive value (PPV) in identifying patients in the emergency department (ED) with cases of stable early pregnancy failure (EPF). We studied females ages 13-50 years presenting to the ED of an urban academic medical center. We approached our analysis from two perspectives, evaluating both the sensitivity and PPV of ICD-9 code "632" in identifying patients with stable EPF. All patients with chief complaints "pregnant and bleeding" or "pregnant and cramping" over a 12-month period were identified. We randomly reviewed two months of patient visits and calculated the sensitivity of ICD-9 code "632" for true cases of stable miscarriage. To establish the PPV of ICD-9 code "632" for capturing missed abortions, we identified patients whose visits from the same time period were assigned ICD-9 code "632," and identified those with actual cases of stable EPF. We reviewed 310 patient records (17.6% of 1,762 sampled). Thirteen of 31 patient records assigned ICD-9 code for missed abortion correctly identified cases of stable EPF (sensitivity=41.9%), and 140 of the 142 patients without EPF were not assigned the ICD-9 code "632"(specificity=98.6%). Of the 52 eligible patients identified by ICD-9 code "632," 39 cases met the criteria for stable EPF (PPV=75.0%). ICD-9 code "632" has low sensitivity for identifying stable EPF, but its high specificity and moderately high PPV are valuable for studying cases of stable EPF in epidemiologic studies using administrative data.

  8. Cu3V2O8 hollow spheres in photocatalysis and primary lithium batteries

    NASA Astrophysics Data System (ADS)

    Zhang, Shaoyan; Sun, Yan; Li, Chunsheng; Ci, Lijie

    2013-11-01

    In this paper, Cu3V2O8 hollow spheres have been successfully synthesized via a liquid precipitation method with colloidal carbon spheres as template followed by a subsequent heat treatment process. On the basis of XRD analysis, SEM observation, and TG-DSC analysis of the precursor and products, the formation mechanism of Cu3V2O8 hollow spheres was proposed. UV-vis diffuse reflectance spectra showed that the Cu3V2O8 hollow spheres exhibit strong absorption in a wide wavelength range from UV to visible light. The photocatalytic activity experiment indicated that the as-prepared Cu3V2O8 hollow spheres exhibited good photocatalytic activity in degradation of methyl orange (MO) under 150-W xenon arc lamp light irradiation. Furthermore, electrochemical measurements showed that the Cu3V2O8 hollow spheres exhibited high discharge capacity and excellent high-rate capability, indicating potential cathode candidates for primary lithium batteries used in long-term implantable cardiac defibrillators (ICDs).

  9. Prospective evaluation of defibrillation threshold and postshock rhythm in young ICD recipients.

    PubMed

    Radbill, Andrew E; Triedman, John K; Berul, Charles I; Walsh, Edward P; Alexander, Mark E; Webster, Gregory; Cecchin, Frank

    2012-12-01

    Adaptation of implantable cardioverter defibrillator (ICD) systems to the needs of pediatric and congenital heart patients is problematic due to constraints of vascular and thoracic anatomy. An improved understanding of the defibrillation energy and postshock pacing requirements in such patients may help direct more tailored ICD therapy. We describe the first prospective evaluation of defibrillation threshold (DFT) and postshock rhythm in this population. We prospectively studied patients ≤ 60 kg at time of ICD intervention. DFTs were obtained using a binary search protocol with three VF inductions. Postshock pacing was programmed using a stepwise protocol, lowering the rate prior to each VF induction. Twenty patients were enrolled: 11 had channelopathy, five congenital heart disease, and four cardiomyopathy. The median age was 16 years, median weight 48 kg. Twelve patients had a transvenous high-voltage coil; eight had pericardial +/- subcutaneous coil(s). Median DFT was 7 J (range 3-31 J); 19/20 patients had DFT ≤ 15 J and all patients <25 kg had DFT ≤ 9 J (n = 6). There was no difference in DFT between patients with transvenous versus pericardial +/- subcutaneous coils (median 7 J vs 6 J, P = 0.59). No patient with normal atrioventricular conduction prior to defibrillation required postshock pacing (n = 16). There were no adverse events. These data suggest that many pediatric ICD patients have low DFTs and adequate postshock escape rhythm. This may help determine appropriate parameters for future design of pediatric-specific ICDs. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  10. The relationship between baseline and follow-up left ventricular ejection fraction with adverse events among primary prevention ICD patients.

    PubMed

    Friedman, Daniel J; Fudim, Marat; Overton, Robert; Shaw, Linda K; Patel, Divyang; Pokorney, Sean D; Velazquez, Eric J; Al-Khatib, Sana M

    2018-07-01

    Left ventricular ejection fraction (LVEF) is used to select patients for primary prevention implantable cardioverter defibrillators (ICDs). The relationship between baseline and long-term follow-up LVEF and clinical outcomes among primary prevention ICD patients remains unclear. We studied 195 patients with a baseline LVEF ≤35% ≤6 months prior to ICD implantation and follow-up LVEF 1-3 years after ICD implantation without intervening left ventricular assist device (LVAD) or transplant. The co-primary study endpoints were: (1) a composite of time to death, LVAD, or transplant and (2) appropriate ICD therapy. We examined multivariable Cox proportional hazard models with a 3-year post-implant landmark view; the LVEF closest to the 3-year mark was considered the follow-up LVEF for analyses. Follow-up LVEF was examined using 2 definitions: (1) ≥10% improvement compared to baseline or (2) actual value of ≥40%. Fifty patients (26%) had a LVEF improvement of ≥10% and 44 (23%) had a follow-up LVEF ≥40%. Neither baseline nor follow-up LVEF was significantly associated with the composite endpoint. In contrast, both baseline and follow-up LVEF were associated with risk for long-term ICD therapies, whether follow-up LVEF was modeled as a ≥10% absolute improvement (baseline LVEF HR 0.87, CI 0.91-0.93, P < .001; follow-up LVEF HR 0.18, CI 0.06-0.53, P = .002) or a ≥40% follow-up value (baseline LVEF HR 0.89, CI 0.83-0.96, P = .001, follow-up LVEF HR 0.26, CI 0.08-0.87, P = .03). Among primary prevention ICD recipients, both baseline and follow-up LVEF were independently associated with long-term risk for appropriate ICD therapy, but they were not associated with time to the composite of LVAD, transplant, or death. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Impact of the diagnostic changes to post-traumatic stress disorder for DSM-5 and the proposed changes to ICD-11.

    PubMed

    O'Donnell, Meaghan L; Alkemade, Nathan; Nickerson, Angela; Creamer, Mark; McFarlane, Alexander C; Silove, Derrick; Bryant, Richard A; Forbes, David

    2014-09-01

    There have been changes to the criteria for diagnosing post-traumatic stress disorder (PTSD) in DSM-5 and changes are proposed for ICD-11. To investigate the impact of the changes to diagnostic criteria for PTSD in DSM-5 and the proposed changes in ICD-11 using a large multisite trauma-exposed sample and structured clinical interviews. Randomly selected injury patients admitted to four hospitals were assessed 72 months post trauma (n = 510). Structured clinical interviews for PTSD and major depressive episode, as well as self-report measures of disability and quality of life were administered. Current prevalence of PTSD under DSM-5 scoring was not significantly different from DSM-IV (6.7% v. 5.9%, z = 0.53, P = 0.59). However, the ICD-11 prevalence was significantly lower than ICD-10 (3.3% v. 9.0%, z = -3.8, P<0.001). The PTSD current prevalence was significantly higher for DSM-5 than ICD-11 (6.7% v. 3.3%, z = 2.5, P = 0.01). Using ICD-11 tended to show lower rates of comorbidity with depression and a slightly lower association with disability. The diagnostic systems performed in different ways in terms of current prevalence rates and levels of comorbidity with depression, but on other broad key indicators they were relatively similar. There was overlap between those with PTSD diagnosed by ICD-11 and DSM-5 but a substantial portion met one but not the other set of criteria. This represents a challenge for research because the phenotype that is studied may be markedly different according to the diagnostic system used. Royal College of Psychiatrists.

  12. Primary ICD-therapy in patients with advanced heart failure: selection strategies and future trials.

    PubMed

    Frankenstein, Lutz; Zugck, Christian; Nelles, Manfred; Schellberg, Dieter; Remppis, Andrew; Katus, Hugo

    2008-09-01

    For allocation of primary ICD-therapy, a possible lower limit of inclusion criteria--defining overly advanced heart failure--is less well investigated. Also, a multi-variable approach to stratification beyond ejection fraction (LVEF) appears warranted. We examined whether adding a selection limit of peak VO(2) ICD-therapy. All cause mortality was considered as end point. Median follow-up was 45 (18-86) months. ICD was not a significant predictor of outcome either for the entire population, or grouped according to aetiology of CHF. Still, 3-year mortality was 15% (ICD-patients) Vs. 28% (non-ICD-patients); P = 0.05; under combination medical therapy. Inversely, in ICD-patients medical combination therapy conveyed a significant survival benefit (P < 0.001). Consequently, the number-needed-to-treat was eight under combination therapy and the size estimate amounts to 300 patients for a prospective trial in this cohort. A cut-off of LVEF ICD-therapy. Our results indicate the need for a specific randomized trial in this cohort. The according mortality data and a size estimate are provided.

  13. Heart rate turbulence predicts ICD-resistant mortality in ischaemic heart disease.

    PubMed

    Marynissen, Thomas; Floré, Vincent; Heidbuchel, Hein; Nuyens, Dieter; Ector, Joris; Willems, Rik

    2014-07-01

    In high-risk patients, implantable cardioverter-defibrillators (ICDs) can convert the mode of death from arrhythmic to pump failure death. Therefore, we introduced the concept of 'ICD-resistant mortality' (IRM), defined as death (a) without previous appropriate ICD intervention (AI), (b) within 1 month after the first AI, or (c) within 1 year after the initial ICD implantation. Implantable cardioverter-defibrillator implantation in patients with a high risk of IRM should be avoided. Implantable cardioverter-defibrillator patients with ischaemic heart disease were included if a digitized 24 h Holter was available pre-implantation. Demographic, electrocardiographic, echocardiographic, and 24 h Holter risk factors were collected at device implantation. The primary endpoint was IRM. Cox regression analyses were used to test the association between predictors and outcome. We included 130 patients, with a mean left ventricular ejection fraction (LVEF) of 33.6 ± 10.3%. During a follow-up of 52 ± 31 months, 33 patients died. There were 21 cases of IRM. Heart rate turbulence (HRT) was the only Holter parameter associated with IRM and total mortality. A higher New York Heart Association (NYHA) class and a lower body mass index were the strongest predictors of IRM. Left ventricular ejection fraction predicted IRM on univariate analysis, and was the strongest predictor of total mortality. The only parameter that predicted AI was non-sustained ventricular tachycardia. Implantable cardioverter-defibrillator implantation based on NYHA class and LVEF leads to selection of patients with a higher risk of IRM and death. Heart rate turbulence may have added value for the identification of poor candidates for ICD therapy. Available Holter parameters seem limited in their ability to predict AI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2013. For permissions please email: journals.permissions@oup.com.

  14. A review of current evidence regarding the ICD-11 proposals for diagnosing PTSD and complex PTSD.

    PubMed

    Brewin, Chris R; Cloitre, Marylène; Hyland, Philip; Shevlin, Mark; Maercker, Andreas; Bryant, Richard A; Humayun, Asma; Jones, Lynne M; Kagee, Ashraf; Rousseau, Cécile; Somasundaram, Daya; Suzuki, Yuriko; Wessely, Simon; van Ommeren, Mark; Reed, Geoffrey M

    2017-12-01

    The World Health Organization's proposals for posttraumatic stress disorder (PTSD) in the 11th edition of the International Classification of Diseases, scheduled for release in 2018, involve a very brief set of symptoms and a distinction between two sibling disorders, PTSD and Complex PTSD. This review of studies conducted to test the validity and implications of the diagnostic proposals generally supports the proposed 3-factor structure of PTSD symptoms, the 6-factor structure of Complex PTSD symptoms, and the distinction between PTSD and Complex PTSD. Estimates derived from DSM-based items suggest the likely prevalence of ICD-11 PTSD in adults is lower than ICD-10 PTSD and lower than DSM-IV or DSM-5 PTSD, but this may change with the development of items that directly measure the ICD-11 re-experiencing requirement. Preliminary evidence suggests the prevalence of ICD-11 PTSD in community samples of children and adolescents is similar to DSM-IV and DSM-5. ICD-11 PTSD detects some individuals with significant impairment who would not receive a diagnosis under DSM-IV or DSM-5. ICD-11 CPTSD identifies a distinct group who have more often experienced multiple and sustained traumas and have greater functional impairment than those with PTSD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Pediatric complex chronic conditions classification system version 2: updated for ICD-10 and complex medical technology dependence and transplantation

    PubMed Central

    2014-01-01

    Background The pediatric complex chronic conditions (CCC) classification system, developed in 2000, requires revision to accommodate the International Classification of Disease 10th Revision (ICD-10). To update the CCC classification system, we incorporated ICD-9 diagnostic codes that had been either omitted or incorrectly specified in the original system, and then translated between ICD-9 and ICD-10 using General Equivalence Mappings (GEMs). We further reviewed all codes in the ICD-9 and ICD-10 systems to include both diagnostic and procedural codes indicative of technology dependence or organ transplantation. We applied the provisional CCC version 2 (v2) system to death certificate information and 2 databases of health utilization, reviewed the resulting CCC classifications, and corrected any misclassifications. Finally, we evaluated performance of the CCC v2 system by assessing: 1) the stability of the system between ICD-9 and ICD-10 codes using data which included both ICD-9 codes and ICD-10 codes; 2) the year-to-year stability before and after ICD-10 implementation; and 3) the proportions of patients classified as having a CCC in both the v1 and v2 systems. Results The CCC v2 classification system consists of diagnostic and procedural codes that incorporate a new neonatal CCC category as well as domains of complexity arising from technology dependence or organ transplantation. CCC v2 demonstrated close comparability between ICD-9 and ICD-10 and did not detect significant discontinuity in temporal trends of death in the United States. Compared to the original system, CCC v2 resulted in a 1.0% absolute (10% relative) increase in the number of patients identified as having a CCC in national hospitalization dataset, and a 0.4% absolute (24% relative) increase in a national emergency department dataset. Conclusions The updated CCC v2 system is comprehensive and multidimensional, and provides a necessary update to accommodate widespread implementation of ICD-10

  16. The discriminatory cost of ICD-10-CM transition between clinical specialties: metrics, case study, and mitigating tools

    PubMed Central

    Boyd, Andrew D; Li, Jianrong ‘John’; Burton, Mike D; Jonen, Michael; Gardeux, Vincent; Achour, Ikbel; Luo, Roger Q; Zenku, Ilir; Bahroos, Neil; Brown, Stephen B; Vanden Hoek, Terry; Lussier, Yves A

    2013-01-01

    Objective Applying the science of networks to quantify the discriminatory impact of the ICD-9-CM to ICD-10-CM transition between clinical specialties. Materials and Methods Datasets were the Center for Medicaid and Medicare Services ICD-9-CM to ICD-10-CM mapping files, general equivalence mappings, and statewide Medicaid emergency department billing. Diagnoses were represented as nodes and their mappings as directional relationships. The complex network was synthesized as an aggregate of simpler motifs and tabulation per clinical specialty. Results We identified five mapping motif categories: identity, class-to-subclass, subclass-to-class, convoluted, and no mapping. Convoluted mappings indicate that multiple ICD-9-CM and ICD-10-CM codes share complex, entangled, and non-reciprocal mappings. The proportions of convoluted diagnoses mappings (36% overall) range from 5% (hematology) to 60% (obstetrics and injuries). In a case study of 24 008 patient visits in 217 emergency departments, 27% of the costs are associated with convoluted diagnoses, with ‘abdominal pain’ and ‘gastroenteritis’ accounting for approximately 3.5%. Discussion Previous qualitative studies report that administrators and clinicians are likely to be challenged in understanding and managing their practice because of the ICD-10-CM transition. We substantiate the complexity of this transition with a thorough quantitative summary per clinical specialty, a case study, and the tools to apply this methodology easily to any clinical practice in the form of a web portal and analytic tables. Conclusions Post-transition, successful management of frequent diseases with convoluted mapping network patterns is critical. The http://lussierlab.org/transition-to-ICD10CM web portal provides insight in linking onerous diseases to the ICD-10 transition. PMID:23645552

  17. Psychotic disorders in DSM-5 and ICD-11.

    PubMed

    Biedermann, Falko; Fleischhacker, W Wolfgang

    2016-08-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) was published by the American Psychiatric Association (APA) in 2013, and the Work Group on the Classification of Psychotic disorders (WGPD), installed by the World Health Organization (WHO), is expected to publish the new chapter about schizophrenia and other primary psychotic disorders in 2017. We reviewed the available literature to summarize the major changes, innovations, and developments of both manuals. If available and possible, we outline the theoretical background behind these changes. Due to the fact that the development of ICD-11 has not yet been completed, the details about ICD-11 are still proposals under ongoing revision. In this ongoing process, they may be revised and therefore have to be seen as proposals. DSM-5 has eliminated schizophrenia subtypes and replaced them with a dimensional approach based on symptom assessments. ICD-11 will most likely go in a similar direction, as both manuals are planned to be more harmonized, although some differences will remain in details and the conceptual orientation. Next to these modifications, ICD-11 will provide a transsectional diagnostic criterion for schizoaffective disorders and a reorganization of acute and transient psychotic and delusional disorders. In this manuscript, we will compare the 2 classification systems.

  18. Body-focused repetitive behavior disorders in ICD-11.

    PubMed

    Grant, Jon E; Stein, Dan J

    2014-01-01

    This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder) should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  19. 77 FR 48985 - Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ... Topics: ICD-10 Implementation Announcements Expansion of Thoracic Aorta Body Part Under Heart and Great... from thoracic aorta to abdominal aorta) ICD-10 MS-DRGs ICD-10 HAC Translations ICD-10 MCE Translations...

  20. Reliability and Validity of the Self Efficacy Expectations and Outcome Expectations After ICD Implantation Scales

    PubMed Central

    Dougherty, Cynthia M.; Johnston, Sandra K.; Thompson, Elaine Adams

    2009-01-01

    The purpose of this study was to assess the reliability and validity characteristics of two new scales that measure self-efficacy expectations (SE-ICD) and outcome expectations (OE-ICD) in survivors (n=168) of sudden cardiac arrest (SCA), all of whom received an implantable cardioverter defibrillator (ICD). Cronbach's alpha reliability demonstrated good internal consistency (SE-ICD α = 0.93 and OE-ICD α = 0.81). Correlations with other self-efficacy instruments (general self-efficacy and social self-efficacy) were consistently high. The instruments were responsive to change across time with effect sizes of 0.46 for SE-ICD, and 0.26 for OE-ICD. These reliable, valid, and responsive instruments for measurement of self-efficacy expectations and outcome expectations after an ICD can be used in research and clinical settings. PMID:17693214

  1. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).

    PubMed

    Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias

    2016-02-15

    Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. An evaluation of comparability between NEISS and ICD-9-CM injury coding.

    PubMed

    Thompson, Meghan C; Wheeler, Krista K; Shi, Junxin; Smith, Gary A; Xiang, Huiyun

    2014-01-01

    To evaluate the National Electronic Injury Surveillance System's (NEISS) comparability with a data source that uses ICD-9-CM coding. A sample of NEISS cases from a children's hospital in 2008 was selected, and cases were linked with their original medical record. Medical records were reviewed and an ICD-9-CM code was assigned to each case. Cases in the NEISS sample that were non-injuries by ICD-9-CM standards were identified. A bridging matrix between the NEISS and ICD-9-CM injury coding systems, by type of injury classification, was proposed and evaluated. Of the 2,890 cases reviewed, 13.32% (n = 385) were non-injuries according to the ICD-9-CM diagnosis. Using the proposed matrix, the comparability of the NEISS with ICD-9-CM coding was favorable among injury cases (κ = 0.87, 95% CI: 0.85-0.88). The distribution of injury types among the entire sample was similar for the two systems, with percentage differences ≥1% for only open wounds or amputation, poisoning, and other or unspecified injury types. There is potential for conducting comparable injury research using NEISS and ICD-9-CM data. Due to the inclusion of some non-injuries in the NEISS and some differences in type of injury definitions between NEISS and ICD-9-CM coding, best practice for studies using NEISS data obtained from the CPSC should include manual review of case narratives. Use of the standardized injury and injury type definitions presented in this study will facilitate more accurate comparisons in injury research.

  3. Safety of mid-septal electrode placement in implantable cardioverter defibrillator recipients--results of the SPICE (Septal Positioning of ventricular ICD Electrodes) study.

    PubMed

    Kolb, Christof; Solzbach, Ulrich; Biermann, Jürgen; Semmler, Verena; Kloppe, Axel; Klein, Norbert; Lennerz, Carsten; Szendey, Istvan; Andrikopoulos, George; Tzeis, Stylianos; Asbach, Stefan

    2014-07-01

    Detrimental effects of right ventricular (RV) apical pacing have directed the interest toward alternative pacing sites such as the RV mid-septum. As safety data are scarce for implantable cardioverter defibrillator (ICD) recipients the study aims to evaluate ICD lead performance in the mid-septal position. A total of 299 ICD recipients (79% male, aged 65.2 ± 12.1 years, 83% primary prevention of sudden cardiac death) were randomized to receive the RV ICD electrode either in a mid-septal (n=145) or apical (n=154) location. Event-free survival was evaluated at 3 (primary endpoint) and 12 months (secondary endpoint). Events included a composite of lead revision, suboptimal right ventricular electrode performance (including defibrillation thresholds (DFT)>25 J) or lead position not in accordance with randomized location. Event-free survival at 3 (12) months was observed in 80.6% (72.3%) of patients randomized to a mid-septal and in 82.2% (72.1%) of patients randomized to an apical lead position, p=0.726 (p=0.969). Pre-defined margins for non-inferiority were not reached at 3 or 12 months. High DFT was found in 7 patients (5.0%) of the mid-septal and in 3 (2.2%) patients of the apical group (p=0.209). In ICD recipients electrode positioning to the RV mid-septum or the RV apex results in slightly different rates concerning the survival free of lead revision, suboptimal right ventricular electrode performance or non-randomized lead position. Non-inferiority of the mid-septal lead location cannot be concluded. This should be taken into consideration when a mid-septal lead position is pursued. ClinicalTrials.gov identifier NCT00745745. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

    PubMed

    Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P

    2015-10-01

    Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.

  5. An Evaluation of Comparability between NEISS and ICD-9-CM Injury Coding

    PubMed Central

    Thompson, Meghan C.; Wheeler, Krista K.; Shi, Junxin; Smith, Gary A.; Xiang, Huiyun

    2014-01-01

    Objective To evaluate the National Electronic Injury Surveillance System’s (NEISS) comparability with a data source that uses ICD-9-CM coding. Methods A sample of NEISS cases from a children’s hospital in 2008 was selected, and cases were linked with their original medical record. Medical records were reviewed and an ICD-9-CM code was assigned to each case. Cases in the NEISS sample that were non-injuries by ICD-9-CM standards were identified. A bridging matrix between the NEISS and ICD-9-CM injury coding systems, by type of injury classification, was proposed and evaluated. Results Of the 2,890 cases reviewed, 13.32% (n = 385) were non-injuries according to the ICD-9-CM diagnosis. Using the proposed matrix, the comparability of the NEISS with ICD-9-CM coding was favorable among injury cases (κ = 0.87, 95% CI: 0.85–0.88). The distribution of injury types among the entire sample was similar for the two systems, with percentage differences ≥1% for only open wounds or amputation, poisoning, and other or unspecified injury types. Conclusions There is potential for conducting comparable injury research using NEISS and ICD-9-CM data. Due to the inclusion of some non-injuries in the NEISS and some differences in type of injury definitions between NEISS and ICD-9-CM coding, best practice for studies using NEISS data obtained from the CPSC should include manual review of case narratives. Use of the standardized injury and injury type definitions presented in this study will facilitate more accurate comparisons in injury research. PMID:24658100

  6. Medium voltage therapy for preventing and treating asystole and PEA in ICDs.

    PubMed

    Gilman, Byron L; Brewer, James E; Kroll, Kai; Kroll, Mark W

    2009-01-01

    Sudden cardiac death (SCD) takes up to 500,000 lives each year before a victim can even be treated. To address this the implantable cardioverter defibrillator (ICD) was developed to treat those identified at high risk of SCD. Unfortunately, there are a significant number of cases in which the ICD does not successfully return a victim to normal rhythm and effective perfusion of the blood. The vast majority of cases that are not responsive to the ICD therapy require cardio-pulmonary resuscitation (CPR) according to current resuscitation guidelines. A novel electrical stimulus called medium voltage therapy (MVT) has shown efficacy in producing coronary and carotid blood flow during ventricular fibrillation. This report presents the case that the same stimulus may be effective and feasible for use in ICD patients that do not respond to their ICD therapy, or do not have a rhythm in which, an ICD shock is indicated. The inclusion of MVT technology in implantable devices may be effective in preparing the heart for successful defibrillation or in improving the metabolic condition of the heart to the extent that a pulsatile rhythm may spontaneously develop.

  7. Dominant Suppression of β1 Integrin by Ectopic CD98-ICD Inhibits Hepatocellular Carcinoma Progression

    PubMed Central

    Wu, Bo; Zhou, Yang; Wang, Yu; Yang, Xiang-Min; Liu, Zhen-Yu; Li, Jiang-Hua; Feng, Fei; Chen, Zhi-Nan; Jiang, Jian-Li

    2016-01-01

    Hepatocellular carcinoma (HCC) is currently the third most common cause of cancer-related death in the Asia-Pacific region. Our previous work showed that knockdown of CD98 significantly inhibits malignant HCC cell phenotypes in vitro and in vivo. The level of CD98 in the membrane is tightly regulated to mediate complex processes associated with cell–cell communication and intracellular signaling. In addition, the intracellular domain of CD98 (CD98-ICD) seems to be of vital importance for recycling CD98 to the membrane after it is endocytosed. The intracellular and transmembrane domains of CD98 associate with β-integrins (primarily β1 but also β3), and this association is essential for CD98 mediation of integrin-like signaling and complements dominant suppression of β1-integrin. We speculated that isolated CD98-ICD would similarly suppress β1-integrin activation and inhibit the malignant behaviors of cancer cells. In particular, the exact role of CD98-ICD has not been studied independently in HCC. In this study, we found that ectopic expression of CD98-ICD inhibited the malignant phenotypes of HCC cells, and the mechanism possibly involves β1-integrin suppression. Moreover, the expression levels of CD98, β1-integrin-A (the activated form of β1-integrin) and Ki-67 were significantly increased in HCC tissues relative to those of normal liver tissues. Therefore, our preliminary study indicates that ectopic CD98-ICD has an inhibitory role in the malignant development of HCC, and shows that CD98-ICD acts as a dominant negative mutant of CD98 that attenuates β1-integrin activation. CD98-ICD may emerge as a promising candidate for antitumor treatment. PMID:27834933

  8. ICD defibrillation failure solved in an unusual fashion.

    PubMed

    Oliveira, Ricardo Gil; Madeira, Francisco; Ferreira, Ana Rita; Antunes, Susana; Morais, Carlos; Gil, Victor

    2010-04-01

    An implantable cardioverter defibrillator (ICD) is designed to sense life-threatening ventricular arrhythmias and terminate them, either by rapid pacing or by delivering an electrical shock. Nowadays it is a proven therapy for both primary and secondary prevention of sudden cardiac death. The typical configuration of an ICD consists of a right ventricular sensing/defibrillator lead with two coils (one distal, located in the right ventricle, and one proximal, located at the superior vena cava-right atrium junction) and an active can, the so-called "ventricular triad". Although effective in the vast majority of patients, it could be argued that this is not the most rational arrangement in electrical terms, since the main shock vector is anteriorly displaced in relation to the greater portion of the left ventricular mass. We describe a case of an ICD defibrillation failure that was solved by placing an additional defibrillator lead in a tributary of the coronary sinus.

  9. Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans.

    PubMed

    Neuzil, Petr; Reddy, Vivek Y; Merkely, Bela; Geller, Laszlo; Molnar, Levente; Bednarek, Jacek; Bartus, Krzysztof; Richey, Mark; Bsee, T J Ransbury; Sanders, William E

    2014-02-01

    A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). The intravascular defibrillator has DFTs similar to those of commercially available ICDs. Published by Heart Rhythm Society on behalf of Heart Rhythm Society.

  10. Design, development and first validation of a transcoding system from ICD-9-CM to ICD-10 in the IT.DRG Italian project.

    PubMed

    Della Mea, Vincenzo; Vuattolo, Omar; Frattura, Lucilla; Munari, Flavia; Verdini, Eleonora; Zanier, Loris; Arcangeli, Laura; Carle, Flavia

    2015-01-01

    In Italy, ICD-9-CM is currently used for coding health conditions at hospital discharge, but ICD-10 is being introduced thanks to the IT-DRG Project. In this project, one needed component is a set of transcoding rules and associated tools for easing coders work in the transition. The present paper illustrates design and development of those transcoding rules, and their preliminary testing on a subset of Italian hospital discharge data.

  11. Evidence of distinct profiles of Posttraumatic Stress Disorder (PTSD) and Complex Posttraumatic Stress Disorder (CPTSD) based on the new ICD-11 Trauma Questionnaire (ICD-TQ).

    PubMed

    Karatzias, Thanos; Shevlin, Mark; Fyvie, Claire; Hyland, Philip; Efthymiadou, Erifili; Wilson, Danielle; Roberts, Neil; Bisson, Jonathan I; Brewin, Chris R; Cloitre, Marylene

    2017-01-01

    The WHO International Classification of Diseases, 11th version (ICD-11), has proposed two related diagnoses following exposure to traumatic events; Posttraumatic Stress Disorder (PTSD) and Complex PTSD (CPTSD). We set out to explore whether the newly developed ICD-11 Trauma Questionnaire (ICD-TQ) can distinguish between classes of individuals according to the PTSD and CPTSD symptom profiles as per ICD-11 proposals based on latent class analysis. We also hypothesized that the CPTSD class would report more frequent and a greater number of different types of childhood trauma as well as higher levels of functional impairment. Methods Participants in this study were a sample of individuals who were referred for psychological therapy to a National Health Service (NHS) trauma centre in Scotland (N=193). Participants completed the ICD-TQ as well as measures of life events and functioning. Overall, results indicate that using the newly developed ICD-TQ, two subgroups of treatment-seeking individuals could be empirically distinguished based on different patterns of symptom endorsement; a small group high in PTSD symptoms only and a larger group high in CPTSD symptoms. In addition, CPTSD was more strongly associated with more frequent and a greater accumulation of different types of childhood traumatic experiences and poorer functional impairment. Sample predominantly consisted of people who had experienced childhood psychological trauma or been multiply traumatised in childhood and adulthood. CPTSD is highly prevalent in treatment seeking populations who have been multiply traumatised in childhood and adulthood and appropriate interventions should now be developed to aid recovery from this debilitating condition. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Follow-up of the first patients with a totally subcutaneous ICD in Germany from implantation till battery depletion.

    PubMed

    Bettin, Markus; Rath, Benjamin; Ellermann, Christian; Leitz, Patrick; Reinke, Florian; Köbe, Julia; Eckardt, Lars; Frommeyer, Gerrit

    2018-06-12

    The subcutaneous ICD is a promising treatment option in patients at risk for sudden cardiac death. Approved in 2009, the first S-ICD ® in Germany was implanted in June 2010. Although large prospective registry studies have shown safety and efficacy of the system, there is a lack of long-term data with regard to battery longevity of the S-ICD ® . Therefore, we report follow-up of our first initial S-ICD ® cases from implantation till battery depletion. All S-ICD ® patients with device replacement for battery depletion in our large single-center S-ICD ® registry were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a median follow-up of 75.9 ± 6.8 months. Twenty-eight patients with S-ICD ® systems were included in this study. Of these patients, 21 were male and 7 were female, with an overall mean age of 41.9 ± 12.6 years. Primary prevention of sudden cardiac death was the indication in 19 patients (67.9%). Ventricular tachycardia was adequately terminated in two patients (7.1%). In 7 patients, non-sustained ventricular arrhythmias were not treated. A total of three inappropriate shocks occurred in three patients (10.7%). Mean time from implantation till battery depletion was 65.8 ± 8.1 months. Only one patient presented premature elective replacement criteria because of rapid battery depletion. No lead-related complication occurred during follow-up and no complications were seen regarding device replacement. In one patient (3.6%), the system was explanted without replacement due to patient's preference. The estimated battery longevity of S-ICD ® of about 5 years was reached in all but one patient. Compared to larger S-ICD ® registry studies, frequency of inappropriate shocks was relatively high in the initial S-ICD ® cases. Both technological improvement as well as programming and operators' experience have led to a reduction of complications. Replacement of the S-ICD

  13. Physicians’ Outlook on ICD-10-CM/PCS and Its Effect on Their Practice

    PubMed Central

    Watzlaf, Valerie; Alkarwi, Zahraa; Meyers, Sandy; Sheridan, Patty

    2015-01-01

    Background The United States is one of the last countries to change from ICD-9-CM to ICD-10-CM/PCS. The compliance date for implementation of ICD-10-CM/PCS is expected to fall on October 1, 2015. Objectives Evaluate physicians’ perceptions on the change from ICD-9-CM to ICD-10-CM/PCS and its effect on their practice, determine how HIM professionals can assist in this transition, and assess what resources are needed to aid in the transition. Results Twenty physicians were asked to participate in one of three focus groups. Twelve physicians (60 percent) agreed to participate. Top concerns included electronic health record software readiness, increase in documentation specificity and time, ability of healthcare professionals to learn a new language, and inadequacy of current training methods and content. Conclusion Physicians expressed that advantages of ICD-10-CM/PCS were effective data analytics and complexity of patient cases with more specific codes. Health information management professionals were touted as needed during the transition to create simple, clear specialty guides and crosswalks as well as education and training tools specific for physicians. PMID:26807074

  14. A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy).

    PubMed

    Pedersen, Susanne S; Mastenbroek, Mirjam H; Carter, Nathan; Barr, Craig; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D; Boersma, Lucas; Johansen, Jens B; Theuns, Dominic A M J

    2016-08-15

    The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of life (QoL) is not known. We evaluated the QoL of patients with an S-ICD against an unrelated cohort with a transvenous (TV)-ICD system during 6 months of follow-up. Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system on a priori selected variables including baseline QoL. QoL was measured with the Short-Form Health Survey at baseline, 3, and 6 months after implant and compared using multivariable modeling with repeated measures. Patients with an S-ICD (n = 167) versus a TV-ICD system (n = 167) did not differ significantly on physical (p = 0.8157) and mental QoL scores (p = 0.9080) across baseline, 3, and 6 months after implantation in adjusted analyses. The evolution in physical (p = 0.0503) and mental scores (p = 0.3772) during follow-up was similar for both cohorts, as indicated by the nonsignificant interaction effect for ICD system by time. Both patients with an S-ICD system and a TV-ICD system experienced significant improvements in physical and mental QoL between time of implant and 3 months (both p's <0.0001) and between time of implant and 6 months (both p's <0.0001) but not between 3 and 6 months (both p's >0.05). In conclusion, these first results show that the QoL of patients with an S-ICD versus TV-ICD system is similar and that patients with either system experience improvements in QoL on the short term. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Overcoming barriers to population-based injury research: development and validation of an ICD10-to-AIS algorithm.

    PubMed

    Haas, Barbara; Xiong, Wei; Brennan-Barnes, Maureen; Gomez, David; Nathens, Avery B

    2012-02-01

    Hospital administrative databases are a useful source of population-level data on injured patients; however, these databases use the International Classification of Diseases (ICD) system, which does not provide a direct means of estimating injury severity. We created and validated a crosswalk to derive Abbreviated Injury Scale (AIS) scores from injury-related diagnostic codes in the tenth revision of the ICD (ICD-10). We assessed the validity of the crosswalk using data from the Ontario Trauma Registry Comprehensive Data Set (OTRCDS). The AIS and Injury Severity Scores (ISS) derived using the algorithm were compared with those assigned by expert abstractors. We evaluated the ability of the algorithm to identify patients with AIS scores of 3 or greater. We used κ and intraclass correlation coefficients (ICC) as measures of concordance. In total, 10 431 patients were identified in the OTRCDS. The algorithm accurately identified patients with at least 1 AIS score of 3 or greater (κ 0.65), as well as patients with a head AIS score of 3 or greater (κ 0.78). Mapped and abstracted ISS were similar; ICC across the entire cohort was 0.83 (95% confidence interval 0.81-0.84), indicating good agreement. When comparing mapped and abstracted ISS, the difference between scores was 10 or less in 87% of patients. Concordance between mapped and abstracted ISS was similar across strata of age, mechanism of injury and mortality. Our ICD-10-to-AIS algorithm produces reliable estimates of injury severity from data available in administrative databases. This algorithm can facilitate the use of administrative data for population-based injury research in jurisdictions using ICD-10.

  16. Real structure of (Sb1/3Zn2/3)GaO3(ZnO)3, a member of the homologous series ARO3(ZnO)m with ordered site occupation

    NASA Astrophysics Data System (ADS)

    Garling, Jennifer; Assenmacher, Wilfried; Schmid, Herbert; Longo, Paolo; Mader, Werner

    2018-02-01

    The hitherto unknown compound (Sb1/3Zn2/3)GaO3(ZnO)3, a member of the homologous series with general formula ARO3(ZnO)m (A,R = trivalent metal cation), was prepared by solid state methods from the binary oxides in sealed Pt-tubes. The structure of (Sb1/3Zn2/3)GaO3(ZnO)3 has been determined by X-ray diffraction from flux-grown single crystals (R 3 ̅ m , Z = 3, aR = 3.2387(7) Å, cR = 41.78(1) Å. The analysis revealed that (Sb1/3Zn2/3)GaO3(ZnO)m is isostructural with InGaO3(ZnO)m, where In3+ on octahedral sites is replaced by Sb5+ and Zn2+ in a ratio of 1:2, preserving an average charge of 3+. (Sb1/3Zn2/3)GaO3(ZnO)3 was furthermore analyzed by electron diffraction, High Angle Annular Dark Field (HAADF) scanning TEM, and high precision EELS spectroscopic imaging, where a periodic ordering of SbO6 octahedra connected via edge sharing to six ZnO6 octahedra in the octahedral layers in a honeycomb motif is found. Due to the large lateral distance of ca. 1.4 nm between adjacent octahedral layers, electrostatic interaction might hardly dictate Sb and Zn positions in neighbouring layers, and hence is a characteristic of the real structure of (Sb1/3Zn2/3)GaO3(ZnO)3. A structure model of the compound in space group P3112 (Nr. 151) with strictly ordered and discrete Sb and Zn positions is derived by crystallographic transformations as closest approximant for the real structure of (Sb1/3Zn2/3)GaO3(ZnO)3. UV-vis measurements confirm this compound to be a transparent oxide with an optical band gap in the UV region with Eg = 3.15 eV.

  17. Obsessive-compulsive disorder for ICD-11: proposed changes to the diagnostic guidelines and specifiers

    PubMed Central

    Simpson, Helen Blair; Reddy, Y. C. Janardhan

    2016-01-01

    Since the approval of the ICD-10 by the World Health Organization (WHO) in 1990, global research on obsessive-compulsive disorder (OCD) has expanded dramatically. This article evaluates what changes may be needed to enhance the scientific validity, clinical utility, and global applicability of OCD diagnostic guidelines in preparation for ICD-11. Existing diagnostic guidelines for OCD were compared. Key issues pertaining to clinical description, differential diagnosis, and specifiers were identified and critically reviewed on the basis of the current literature. Specific modifications to ICD guidelines are recommended, including: clarifying the definition of obsessions (i.e., that obsessions can be thoughts, images, or impulses/urges) and compulsions (i.e., clarifying that these can be behaviors or mental acts and not calling these “stereotyped”); stating that compulsions are often associated with obsessions; and removing the ICD-10 duration requirement of at least 2 weeks. In addition, a diagnosis of OCD should no longer be excluded if comorbid with Tourette syndrome, schizophrenia, or depressive disorders. Moreover, the ICD-10 specifiers (i.e., predominantly obsessional thoughts, compulsive acts, or mixed) should be replaced with a specifier for insight. Based on new research, modifications to the ICD-10 diagnostic guidelines for OCD are recommended for ICD-11. PMID:25388607

  18. Device Longevity in a Contemporary Cohort of ICD/CRT-D Patients Undergoing Device Replacement.

    PubMed

    Zanon, Francesco; Martignani, Cristian; Ammendola, Ernesto; Menardi, Endrj; Narducci, Maria Lucia; DE Filippo, Paolo; Santamaria, Matteo; Campana, Andrea; Stabile, Giuseppe; Potenza, Domenico Rosario; Pastore, Gianni; Iori, Matteo; LA Rosa, Concetto; Biffi, Mauro

    2016-07-01

    The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th-75th percentile, 4.9-6.9) for single- and dual-chamber ICD and 4.9 years (25th-75th percentile, 4.0-5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers. © The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  19. Gender incongruence of childhood in the ICD-11: controversies, proposal, and rationale.

    PubMed

    Drescher, Jack; Cohen-Kettenis, Peggy T; Reed, Geoffrey M

    2016-03-01

    As part of the development of the eleventh revision of the International Classification of Diseases (ICD-11), WHO appointed a Working Group on Sexual Disorders and Sexual Health to recommend changes necessary in the classification of mental and behavioural disorders in ICD-10 that are related to sexuality and gender identity. This Personal View focuses on the Working Group's proposals to include the diagnosis gender incongruence of childhood in ICD-11 and to move gender incongruence of childhood out of the mental and behavioural disorders chapter of ICD-11. We outline the history of ICD and DSM child gender diagnoses, expert consensus, knowledge gaps, and controversies related to the diagnosis and treatment of extremely gender-variant children. We argue that retaining the gender incongruence of childhood category is justified as a basis to structure clinical care and to ensure access to appropriate services for this vulnerable population, which provides opportunities for education and informed consent, the development of standards and pathways of care to help guide clinicians and family members, and a basis for future research efforts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Right versus left parasternal electrode position in the entirely subcutaneous ICD.

    PubMed

    Bettin, Markus; Dechering, Dirk; Frommeyer, Gerrit; Larbig, Robert; Löher, Andreas; Reinke, Florian; Köbe, Julia; Eckardt, Lars

    2018-05-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD ® ) has been established as an alternative to conventional transvenous ICD for the prevention of sudden cardiac death. Initial studies have shown safety and efficacy of the system with a left parasternal (LP) electrode. However, several case studies reported a right parasternal (RP) position. The purpose of this study was to analyze shock efficacy and safety of an RP electrode position. Between June 2010 and May 2016, 120 S-ICD ® were implanted at our institution. On the basis of the heart location on preoperative chest radiography (CXR), the investigators decided on an RP (n = 52) or LP electrode position (n = 68). All perioperative induced VF episodes, and spontaneous appropriate and inappropriate episodes during follow-up were analyzed. Patients with an RP electrode did not differ in terms of age, sex, or ejection fraction. A statistically significant difference in underlying cardiac disease was observed between the RP and LP electrode group, with more patients with channelopathies in the RP electrode group and more patients with non-ischemic cardiomyopathy in the LP electrode group. During a mean follow-up of 24.3 ± 19.5 months, 27 appropriate (19 in the LP group and 8 in the RP group) and 28 inappropriate (18 LP and 10 RP) ICD shocks occurred (p value = NS). In the present study, an RP electrode position was chosen on the basis of chest radiographic characteristics and was efficient in terms of sensing and shock efficacy. Thus, a right-sided electrode implant might be an alternative if a left-sided electrode implant is inadequate. It might also be favorable for young patients with narrow heart silhouettes in the midsagittal position.

  1. Impulse control disorders and related behaviours (ICD-RBs) in Parkinson's disease patients: Assessment using "Questionnaire for impulsive-compulsive disorders in Parkinson's disease" (QUIP).

    PubMed

    Sharma, Ashish; Goyal, Vinay; Behari, Madhuri; Srivastva, Achal; Shukla, Garima; Vibha, Deepti

    2015-01-01

    There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs) in Indian patients with Parkinson's Disease (PD). In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated "Questionnaire for Impulsive-Compulsive Disorders in Parkinson's disease (QUIP)" and to examine their association with Dopamine replacement therapy (DRT). This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver) were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%), at least one Impulse control disorder (ICD) was present in 74 (24.75%) and at least one Impulse control related compulsive behaviour (ICRB) was present in 93 (31.1%) patients. Punding was the most frequent (12.4%) followed by hyper sexuality (11.04%), compulsive hobbyism (9.4%), compulsive shopping (8.4%), compulsive medication use (7.7%), compulsive eating (5.35%), walkabout (4%) and pathological gambling (3.3%). ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD) were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Our study revealed a relatively higher frequency of ICD-RBs, probably because of the use of screening instrument and because

  2. Refusing Implantable Cardioverter Defibrillator (ICD) Replacement in Elderly Persons-The Same as Giving Up Life: A Qualitative Study.

    PubMed

    Svanholm, Jette Rolf; Nielsen, Jens Cosedis; Mortensen, Peter; Christensen, Charlotte Fuglesang; Birkelund, Regner

    2015-11-01

    More than 20% of implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy (CRT) devices are implanted in the elderly population aged 80 years or older. In recent scientific literature it is suggested to consider termination of ICD therapy, rather than ICD replacement, in this patient group. The aim of this study was to explore the experiences of persons above 80 years of age concerning replacement of the ICD battery, and the shared communication and decision making with healthcare professionals. We performed a qualitative, explorative study, inspired by Ricoeur's narrative, with a phenomenological-hermeneutic approach, involving 11 ICD patients older than 80 years. The study period was 2011-2012. The meaning of the patients' experiences of living with an ICD was formulated into two themes: (1) "Feeling safe with the ICD" with the subthemes: "The ICD-a life keeper," "The battery level is important," "ICD shock-no problem." (2) "The physician is an authority" with the subthemes: "Being trustful," "Feeling fine knowing nothing," "Criminal act to deactivate the ICD." The elderly ICD recipients tended not to be aware of the option of declining replacement of their ICD. They tended to expect to have their ICD replaced and not to be involved actively in decision making concerning this. Healthcare professionals have an obligation to discuss options and ensure that every patient understands these. More research is needed to change practices and create more realistic, person-centered, ethically acceptable, and constructive healthcare for elderly persons with an ICD. © 2015 Wiley Periodicals, Inc.

  3. Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.

    PubMed

    Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal

    2016-01-01

    The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  4. Mental and behavioural disorders in the ICD-11: concepts, methodologies, and current status.

    PubMed

    Gaebel, Wolfgang; Zielasek, Jürgen; Reed, Geoffrey M

    2017-04-30

    This review provides an overview of the concepts, methods and current status of the development of the Eleventh Revision of the Mental and Behavioural Disorders chapter of the International Classification of Diseases and Related Health Problems (ICD-11) by the World Health Organization (WHO). Given the global use of the current version (ICD-10) for a wide range of applications in clinical practice and health statistics, a major aim of the development process for ICD-11 has been to increase the utility of the classification system. Expert working groups with responsibility for specific disorder groupings first suggested a set of revised diagnostic guidelines. Then surveys were performed to obtain suggestions for revisions from practicing health professionals. A completely revised structure for the classification of mental and behavioural disorders was developed and major revisions were suggested, for example, for schizophrenia and other primary psychotic disorders, substance use disorders, affective disorders and personality disorders. A new category of "gaming disorder" has been proposed and conditions related to sexual health and gender identity will be classified separately from mental disorders. An ICD-11 beta draft is freely available on the internet and public comments are invited. Field studies of the revised diagnostic guidelines are in process to obtain additional information about necessary improvements. A tabulated crosswalk from previous ICD-10 to then ICD-11 criteria will be necessary to ascertain the continuity of diagnoses for epidemiological and other statistical purposes. The final version of ICD-11 is currently scheduled for release by the World Health Assembly in 2018.

  5. Steps through the revision process of reproductive health sections of ICD-11.

    PubMed

    Chou, Doris; Tunçalp, Özge; Hotamisligil, Selen; Norman, Jane; Say, Lale; Volkmer, Björn; Pattinson, Bob; Rooney, Cleo; Serour, Gamal; de Mouzon, Jacques; Gardosi, Jason; Thueroff, Joachim; Mark, Morgan; D'Hooghe, Thomas

    2012-01-01

    In 2007, the WHO initiated an organizational structure for the 11th revision of the International Classification of Diseases (ICD). Effective deployment of ICD-derived tools facilitates the use and collection of health information in a variety of resource settings, promoting quantitatively informed decisions. They also facilitate comparison of disease incidence and outcomes between different countries and different health care systems around the world. The Department of Reproductive Health and Research (RHR) coordinates the revision of chapters 14 (diseases of the genitourinary system), 15 (pregnancy, childbirth, and puerperium), and 16 (conditions originating in the perinatal period). RHR convened a technical advisory group (TAG), the Genito-Urinary Reproductive Medicine (GURM) TAG, for the ICD revision. The TAG's work reflects the collective understanding of sexual and reproductive health and is now available for review within the ICD-11 revision process. Copyright © 2012 S. Karger AG, Basel.

  6. The Role of Conventional and Right-Sided ECG Screening for Subcutaneous ICD in a Tetralogy of Fallot Population.

    PubMed

    Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José

    2017-02-01

    Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P < 0.0001) and a trend to higher number of appropriate leads in right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P < 0.001). Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.

  7. Overcoming barriers to population-based injury research: development and validation of an ICD-10–to–AIS algorithm

    PubMed Central

    Haas, Barbara; Xiong, Wei; Brennan-Barnes, Maureen; Gomez, David; Nathens, Avery B.

    2012-01-01

    Background Hospital administrative databases are a useful source of population-level data on injured patients; however, these databases use the International Classification of Diseases (ICD) system, which does not provide a direct means of estimating injury severity. We created and validated a crosswalk to derive Abbreviated Injury Scale (AIS) scores from injury-related diagnostic codes in the tenth revision of the ICD (ICD-10). Methods We assessed the validity of the crosswalk using data from the Ontario Trauma Registry Comprehensive Data Set (OTR-CDS). The AIS and Injury Severity Scores (ISS) derived using the algorithm were compared with those assigned by expert abstractors. We evaluated the ability of the algorithm to identify patients with AIS scores of 3 or greater. We used κ and intraclass correlation coefficients (ICC) as measures of concordance. Results In total, 10 431 patients were identified in the OTR-CDS. The algorithm accurately identified patients with at least 1 AIS score of 3 or greater (κ 0.65), as well as patients with a head AIS score of 3 or greater (κ 0.78). Mapped and abstracted ISS were similar; ICC across the entire cohort was 0.83 (95% confidence interval 0.81–0.84), indicating good agreement. When comparing mapped and abstracted ISS, the difference between scores was 10 or less in 87% of patients. Concordance between mapped and abstracted ISS was similar across strata of age, mechanism of injury and mortality. Conclusion Our ICD-10–to–AIS algorithm produces reliable estimates of injury severity from data available in administrative databases. This algorithm can facilitate the use of administrative data for population-based injury research in jurisdictions using ICD-10. PMID:22269308

  8. Collaboration between specialties for respiratory allergies in the International Classification of Diseases (ICD)-11.

    PubMed

    Tanno, Luciana Kase; Calderon, Moises; Linzer, Jeffrey F; Chalmers, Robert J G; Demoly, Pascal

    2017-02-10

    The International Classification of Diseases (ICD) has been grouping the allergic and hypersensitivity disorders involving the respiratory tract under topographic distribution, regardless of the underlying mechanisms, triggers or concepts currently in use for allergic and hypersensitivity conditions. In order to strengthen awareness and deliberate the creation of the new "Allergic or hypersensitivity disorders involving the respiratory tract" section of the ICD-11, we here propose make the building process public. The new frame has been constructed to cover the gaps previously identified and was based on consensus academic reports and ICD-11 principles. Constant and bilateral discussion was kept with relevant groups representing specialties and resulted in proposals submission into the ICD-11 online platform. The "Allergic or hypersensitivity disorders involving the respiratory tract" section covers 64 entities distributed across five main categories. All the 79 proposals submitted resulted from an intensive collaboration of the Allergy working group, relevant Expert working groups and the WHO ICD governance. The establishment of the ICD-11 "Allergic or hypersensitivity disorders involving the respiratory tract" section will allow the dissemination of the updated concepts to be used in clinical practice by many different specialties and health professionals.

  9. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations.

    PubMed

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-08-05

    With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Accuracy of ICD-10 Coding System for Identifying Comorbidities and Infectious Conditions Using Data from a Thai University Hospital Administrative Database.

    PubMed

    Rattanaumpawan, Pinyo; Wongkamhla, Thanyarak; Thamlikitkul, Visanu

    2016-04-01

    To determine the accuracy of International Statistical Classification of Disease and Related Health Problems, 10th Revision (ICD-10) coding system in identifying comorbidities and infectious conditions using data from a Thai university hospital administrative database. A retrospective cross-sectional study was conducted among patients hospitalized in six general medicine wards at Siriraj Hospital. ICD-10 code data was identified and retrieved directly from the hospital administrative database. Patient comorbidities were captured using the ICD-10 coding algorithm for the Charlson comorbidity index. Infectious conditions were captured using the groups of ICD-10 diagnostic codes that were carefully prepared by two independent infectious disease specialists. Accuracy of ICD-10 codes combined with microbiological dataf or diagnosis of urinary tract infection (UTI) and bloodstream infection (BSI) was evaluated. Clinical data gathered from chart review was considered the gold standard in this study. Between February 1 and May 31, 2013, a chart review of 546 hospitalization records was conducted. The mean age of hospitalized patients was 62.8 ± 17.8 years and 65.9% of patients were female. Median length of stay [range] was 10.0 [1.0-353.0] days and hospital mortality was 21.8%. Conditions with ICD-10 codes that had good sensitivity (90% or higher) were diabetes mellitus and HIV infection. Conditions with ICD-10 codes that had good specificity (90% or higher) were cerebrovascular disease, chronic lung disease, diabetes mellitus, cancer HIV infection, and all infectious conditions. By combining ICD-10 codes with microbiological results, sensitivity increased from 49.5 to 66%for UTI and from 78.3 to 92.8%for BS. The ICD-10 coding algorithm is reliable only in some selected conditions, including underlying diabetes mellitus and HIV infection. Combining microbiological results with ICD-10 codes increased sensitivity of ICD-10 codes for identifying BSI. Future research is

  11. Impulse control disorders and related behaviours (ICD-RBs) in Parkinson's disease patients: Assessment using “Questionnaire for impulsive-compulsive disorders in Parkinson's disease” (QUIP)

    PubMed Central

    Sharma, Ashish; Goyal, Vinay; Behari, Madhuri; Srivastva, Achal; Shukla, Garima; Vibha, Deepti

    2015-01-01

    Background: There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs) in Indian patients with Parkinson's Disease (PD). In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. Objectives: To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated “Questionnaire for Impulsive-Compulsive Disorders in Parkinson's disease (QUIP)” and to examine their association with Dopamine replacement therapy (DRT). Materials and Methods: This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver) were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Results: Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%), at least one Impulse control disorder (ICD) was present in 74 (24.75%) and at least one Impulse control related compulsive behaviour (ICRB) was present in 93 (31.1%) patients. Punding was the most frequent (12.4%) followed by hyper sexuality (11.04%), compulsive hobbyism (9.4%), compulsive shopping (8.4%), compulsive medication use (7.7%), compulsive eating (5.35%), walkabout (4%) and pathological gambling (3.3%). ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD) were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Conclusions: Our study revealed a relatively higher frequency of

  12. Effective Identification of Similar Patients Through Sequential Matching over ICD Code Embedding.

    PubMed

    Nguyen, Dang; Luo, Wei; Venkatesh, Svetha; Phung, Dinh

    2018-04-11

    Evidence-based medicine often involves the identification of patients with similar conditions, which are often captured in ICD (International Classification of Diseases (World Health Organization 2013)) code sequences. With no satisfying prior solutions for matching ICD-10 code sequences, this paper presents a method which effectively captures the clinical similarity among routine patients who have multiple comorbidities and complex care needs. Our method leverages the recent progress in representation learning of individual ICD-10 codes, and it explicitly uses the sequential order of codes for matching. Empirical evaluation on a state-wide cancer data collection shows that our proposed method achieves significantly higher matching performance compared with state-of-the-art methods ignoring the sequential order. Our method better identifies similar patients in a number of clinical outcomes including readmission and mortality outlook. Although this paper focuses on ICD-10 diagnosis code sequences, our method can be adapted to work with other codified sequence data.

  13. Application of radiofrequency energy in surgical and interventional procedures: are there interactions with ICDs?

    PubMed

    Fiek, Michael; Dorwarth, Uwe; Durchlaub, Ilka; Janko, Sabine; Von Bary, Christian; Steinbeck, Gerhard; Hoffmann, Ellen

    2004-03-01

    During surgical and interventional procedures, interference may occur between ICDs and electrical cautery or with the application of RF energy. This may lead to the false induction of ICD therapies or could even result in device malfunction, which represents a potential perioperative hazard for the patient. This study analyzed the intraoperative interactions in 45 consecutive ICD patients in reference to different surgical and interventional procedures. A total of 33 surgical operations (general surgery [n = 14], urologic [n = 5], abdominal [n = 10], gynecological [n = 2], thoracic [n = 1], neurosurgical [n = 1]) and 12 interventional therapies (RF catheter ablation [n = 10], endoscopic papillotomy [n = 2]) were performed. The ICD devices were all located in left pectoral position and consisted of 25 single and 20 dual chamber defibrillators. During the procedure, tachyarrhythmia detection (VF 296 +/- 20 ms, VT 376 +/- 49 ms) of the devices was maintained active (monitoring mode), only ICD therapies were inactivated. The indifferent electrode of the electrical cauter/RF generator was placed in standard positions (right/left mid-femoral position [n = 27/8], thoracic spine area [n = 10]). After the procedure, the ICD memory was checked for detections and for changes in the programming. There was no oversensing, reprogramming, or damage of any defibrillator caused by RF energy. Despite the lack of undesired interactions, ICDs should be inactivated preoperatively to assure maximum patient safety. However, should inactivation not be possible, or the achievement uncertain, electromagnetic interference is highly unlikely.

  14. Intermolecular Coulombic Decay (ICD) Occuring in Triatomic Molecular Dimer

    NASA Astrophysics Data System (ADS)

    Iskandar, Wael; Gatton, Averell; Gaire, Bishwanath; Champenois, Elio; Larsen, Kirk; Shivaram, Niranjan; Moradmand, Ali; Severt, Travis; Williams, Joshua; Slaughter, Daniel; Weber, Thorsten

    2017-04-01

    For over two decades, the production of ICD process has been extensively investigated theoretically and experimentally in different systems bounded by a week force (ex. van-der-Waals or Hydrogen force). Furthermore, the ICD process has been demonstrated a strong implication in biological system (DNA damage and DNA repair mechanism) because of the production of genotoxic low energy electrons during the decay cascade. Studying large complex system such as triatomic molecular dimer may be helpful for further exploration of ``Auger electron driven cancer therapy''. The present experiment investigates the dissociation dynamics happened in collision between a photons and CO2 dimer. We will focus more specifically on the CO2++CO2+ fragmentation channel and the detection in coincidence of the two ionic fragments and the two electrons will be done using a COld Target Recoil Ion Momentum Spectroscopy (COLTRIMS). The measurements of the Kinetic Energy Release of the two fragments and the relative angular distribution of the electrons in the molecular frame reveal that the ICD is the only mechanism responsible for the production of this fragmentation channel.

  15. The impact of proposed changes to ICD-11 on estimates of PTSD prevalence and comorbidity.

    PubMed

    Wisco, Blair E; Miller, Mark W; Wolf, Erika J; Kilpatrick, Dean; Resnick, Heidi S; Badour, Christal L; Marx, Brian P; Keane, Terence M; Rosen, Raymond C; Friedman, Matthew J

    2016-06-30

    The World Health Organization's posttraumatic stress disorder (PTSD) work group has published a proposal for the forthcoming edition of the International Classification of Diseases (ICD-11) that would yield a very different diagnosis relative to DSM-5. This study examined the impact of the proposed ICD-11 changes on PTSD prevalence relative to the ICD-10 and DSM-5 definitions and also evaluated the extent to which these changes would accomplish the stated aim of reducing the comorbidity associated with PTSD. Diagnostic prevalence estimates were compared using a U.S. national community sample and two U.S. Department of Veterans Affairs clinical samples. The ICD-11 definition yielded prevalence estimates 10-30% lower than DSM-5 and 25% and 50% lower than ICD-10 with no reduction in the prevalence of common comorbidities. Findings suggest that by constraining the diagnosis to a narrower set of symptoms, the proposed ICD-11 criteria set would substantially reduce the number of individuals with the disorder. These findings raise doubt about the extent to which the ICD-11 proposal would achieve the aim of reducing comorbidity associated with PTSD and highlight the public health and policy implications of such a redefinition. Published by Elsevier Ireland Ltd.

  16. Chronic lymphocytic leukemia skin infiltration mimicking an ICD pocket infection: a case report.

    PubMed

    Snorek, M; Bulava, A; Vonke, I

    2017-03-24

    We are presenting a case report on an unreported and unusual cutaneous manifestation of chronic lymphocytic leukemia in a patient with an implantable cardioverter-defibrillator (ICD). A 65-year-old man with a history of chronic lymphocytic leukemia (CLL), previously treated with chlorambucil, was referred in October 2013 for extraction of a single chamber ICD due to a suspected device-related infection in the pulse generator area (left-hand side of Fig. 1). The ICD system (Current VR, St. Jude Medical, USA) had been implanted in November 2009. The patient complained of painless erythema with pruritus in the pocket area. Inflammatory blood parameters were C-reactive protein 17.3 mg/L and leucocytes 29.0 × 10 9 /L. Due to the atypical appearance of the pocket area we did not extract the device. Instead, we created an exploratory excision in the skin induration, which had been present for approximately 6 weeks, and conducted a microbiological and histological examination. All cultivation examinations were negative. However, we did histologically show skin infiltration by CD-5 positive low-grade B-cell chronic lymphocytic leukemia/small lymphocytic lymphoma (B-CLL/SLL). Re-initiation of chemotherapy was not necessary and the skin induration completely disappeared within 2 months (right-hand side of Fig. 1). Complete removal of an ICD system carries considerable risk. In patients with a history of hematological disease, it is crucial to exclude cutaneous manifestations of the disease prior to device removal.

  17. Trends in Gastroenteritis-associated Mortality in the United States 1985-2005: Variations by ICD-9 and ICD-10 Codes

    EPA Science Inventory

    BackgroundTrends in gastroenteritis-associated mortality are changing over time with development of antibiotic resistant strains of certain pathogens, improved diagnostic methods, and changing healthcare. In 1999, ICD-10 coding was introduced for mortality records which can also ...

  18. Feasibility of heart sounds measurements from an accelerometer within an ICD pulse generator.

    PubMed

    Siejko, Krzysztof Z; Thakur, Pramodsingh H; Maile, Keith; Patangay, Abhilash; Olivari, Maria-Teresa

    2013-03-01

    The feasibility of detecting heart sounds (HS) from an accelerometer sensor enclosed within an implantable cardioverter defibrillator (ICD) pulse generator (PG) was explored in a noninvasive pilot study on heart failure (HF) patients with audible third HS (S3). Accelerometer circuitry enhanced for HS was incorporated into non-functional ICDs. A study was conducted on 30 HF patients and 10 normal subjects without history of cardiac disease. The devices were taped to the skin surface over both left and right pectoral regions to simulate subcutaneous implants. A lightweight reference accelerometer was taped over the cardiac apex. Waveforms were recorded simultaneously with a surface electrocardiogram for 2 minutes. Algorithms were developed to perform off-line automatic detection of HS and HS time intervals (HSTIs). S1, S2, and S3 vibrations were detected in all accelerometer locations for all 40 subjects, including 16 subjects without an audible S3. A substantial proportion of S3 energy was infrasonic (<20 Hz). Extending the signal bandwidth accordingly increased HS amplitudes and the ability of S3 to separate HF patients from the normal subgroup. HSTIs also separated the subgroups and were less susceptible to patient-dependent acoustic propagation properties than amplitude measures. HS, including S3 amplitude and HSTIs, may be measured using PG-embedded circuitry at implant sites without special purpose leads. Further study is warranted to determine if relative changes in heart sounds measurements can be effective in applications such as remote ambulatory monitoring of HF progression and the detection of the onset of HF decompensation. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  19. SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalavagunta, C; Lasio, G; Yi, B

    2015-06-15

    Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquiredmore » for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.« less

  20. Reactivity of Hydrogen and Methanol on (001) Surfaces of WO3, ReO3, WO3/ReO3 and ReO3/WO3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Sanliang; Mei, Donghai; Gutowski, Maciej S.

    2011-05-16

    Bulk tungsten trioxide (WO3) and rhenium trioxide (ReO3) share very similar structures but display different electronic properties. WO3 is a wide bandgap semiconductor while ReO3 is an electronic conductor. With the advanced molecular beam epitaxy techniques, it is possible to make heterostructures comprised of layers of WO3 and ReO3. These heterostructures might display reactivity different than pure WO3 and ReO3. The interactions of two probe molecules (hydrogen and methanol) with the (001) surfaces of WO3, ReO3, and two heterostructures ReO3/WO3 and WO3/ReO3 were investigated at the density functional theory level. Atomic hydrogen prefers to adsorb at the terminal O1C sitesmore » forming a surface hydroxyl on four surfaces. Dissociative adsorption of a hydrogen molecule at the O1C site leads to formation of a water molecule adsorbed at the surface M5C site. This is thermodynamically the most stable state. A thermodynamically less stable dissociative state involves two surface hydroxyl groups O1CH and O2CH. The interaction of molecular hydrogen and methanol with pure ReO3 is stronger than with pure WO3 and the strength of the interaction substantially changes on the WO3/ReO3 and ReO3/WO3 heterostructures. The reaction barriers for decomposition and recombination reactions are sensitive to the nature of heterostructure. The calculated adsorption energy of methanol on WO3(001) of -65.6 kJ/mol is consistent with the previous experimental estimation of -67 kJ/mol. This material is based upon work supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science, Office of Basic Energy Sciences.« less

  1. Metrics and tools for consistent cohort discovery and financial analyses post-transition to ICD-10-CM.

    PubMed

    Boyd, Andrew D; Li, Jianrong John; Kenost, Colleen; Joese, Binoy; Yang, Young Min; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A

    2015-05-01

    In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as "convoluted" by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: "identity" (reciprocal), "class-to-subclass," "subclass-to-class," "convoluted," or "no mapping." These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible.Web portal: http://www.lussierlab.org/transition-to-ICD9CM/Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  2. Metrics and tools for consistent cohort discovery and financial analyses post-transition to ICD-10-CM

    PubMed Central

    Boyd, Andrew D; ‘John’ Li, Jianrong; Kenost, Colleen; Joese, Binoy; Min Yang, Young; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A

    2015-01-01

    In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as “convoluted” by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: “identity” (reciprocal), “class-to-subclass,” “subclass-to-class,” “convoluted,” or “no mapping.” These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible. Web portal: http://www.lussierlab.org/transition-to-ICD9CM/ Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9 PMID:25681260

  3. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    PubMed

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  4. Educational videos to reduce racial disparities in ICD therapy via innovative designs (VIVID): a randomized clinical trial.

    PubMed

    Thomas, Kevin L; Zimmer, Louise O; Dai, David; Al-Khatib, Sana M; Allen LaPointe, Nancy M; Peterson, Eric D

    2013-07-01

    Black individuals eligible for an implantable cardioverter/defibrillator (ICD) are considerably less likely than white individuals to receive one. This disparity may, in part, be explained by racial differences in patient preferences. We hypothesized that a targeted patient-centered educational video could improve knowledge of sudden cardiac arrest (SCA) and ICDs and reduce racial differences in ICD preferences. We conducted a pilot study to assess the feasibility of testing this hypothesis in a randomized trial. We created a video that included animation, physician commentary, and patient testimonials on SCA and ICDs. The primary outcome was the decision to have an ICD implanted as a function of race and intervention. Between January 1, 2011, and December 31, 2011, 59 patients (37 white and 22 black) were randomized to the video or health care provider counseling/usual care. Relative to white patients, black patients were younger (median age, 55 vs 68 years) and more likely to have attended college or technical school. Baseline SCA and ICD knowledge was similar and improved significantly in both racial groups after the intervention. Black patients viewing the video were as likely as white patients to want an ICD (60.0% vs 79.2%, P = .20); and among those in the usual care arm, black patients were less likely than white patients to want an ICD (42.9% vs 84.6% P = .05). Among individuals eligible for an ICD, a video decision aid increased patient knowledge and reduced racial differences in patient preference for an ICD. Copyright © 2013 Mosby, Inc. All rights reserved.

  5. Contemporary rates of appropriate shock therapy in patients who receive implantable device therapy in a real-world setting: From the Israeli ICD Registry.

    PubMed

    Sabbag, Avi; Suleiman, Mahmoud; Laish-Farkash, Avishag; Samania, Nimer; Kazatsker, Mark; Goldenberg, Ilan; Glikson, Michael; Beinart, Roy

    2015-12-01

    Implantable cardioverter-defibrillators (ICDs) have become the mainstay of preventive measures for sudden cardiac death (SCD). However, there are limited data on rates of appropriate life-saving ICD shock therapies in contemporary real-life settings. The purpose of the study was to evaluate the rate of appropriate life-saving ICD shock therapies in a contemporary registry. The Israeli ICD Registry includes all implants and other ICD operative procedures nationwide. The present study comprises 2349 consecutive cases who were enrolled in the Registry and prospectively followed up for information regarding survival, hospitalizations, and ICD therapies since 2010. Kaplan-Meier survival analysis showed that the rate of appropriate ICD shock therapy at 30-month follow-up was 2.6% among patients who received an ICD for primary prevention compared with 7.4% among those who received a device for secondary prevention (log-rank P < .001). Rates of appropriate ICD shocks among primary prevention patients were 1.1% at 1-year of follow-up and 2.6% at 30 months, whereas the corresponding rates in the secondary prevention group were 3.8% at 1 year and 7.4% at 30 months (log-rank P < .001). A total of 253 patients (4.8%) died during follow-up, 65% of noncardiac causes. Rates of life-saving appropriate ICD shock therapies among patients implanted with a defibrillator for the primary prevention of SCD in a contemporary real-world setting are lower than reported previously. These findings suggest a need for improved risk stratification and patient selection in this population. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Outcomes in African Americans undergoing cardioverter-defibrillator implantation for primary prevention of sudden cardiac death: findings from the Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD).

    PubMed

    Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F; Cheng, Alan

    2014-08-01

    Implantable cardioverter-defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African Americans (AAs). The purpose of this study was to determine the association between AA race and outcomes in a cohort of primary prevention ICD patients. We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end-point was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary end-point was all-cause mortality. There were 1189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratio (95% confidence interval) comparing AAs vs non-AAs were 1.24 (0.96-1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1%-69.5%), 18.7% (5.3%-58.0%), and 13.6% (3.8%-53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remaining unexplained. In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. Revisiting Desensitization and Allergen Immunotherapy Concepts for the International Classification of Diseases (ICD)-11.

    PubMed

    Tanno, Luciana Kase; Calderon, Moises A; Papadopoulos, Nikolaos G; Sanchez-Borges, Mario; Rosenwasser, Lanny J; Bousquet, Jean; Pawankar, Ruby; Sisul, Juan Carlos; Cepeda, Alfonso Mario; Li, James; Muraro, Antonella; Fineman, Stanley; Sublett, James L; Katelaris, Constance H; Chang, Yoon-Seok; Moon, Hee-Bom; Casale, Thomas; Demoly, Pascal

    2016-01-01

    Allergy and hypersensitivity intervention management procedures, such as desensitization and/or tolerance induction and immunotherapy, have not been pondered up to now in the content of International Classification of Diseases (ICD) context because the focus has been on prioritizing the condition implementations. Tremendous efforts have been devoted to implementing allergic and hypersensitivity conditions in the forthcoming ICD-11. However, we consider that it is crucial now to have nomenclature and classification universally accepted for these procedures to be able to provide scientifically consistent proposals into the new ICD-11 platform for the best practice parameters of our specialty. With the aim of promoting a harmonized comprehension and aligning it with the ICD-11 revision, we have reviewed the definitions and concepts currently used for desensitization and/or tolerance induction and immunotherapy. We strongly believe that this review is a key instrument to support the allergy specialty identity into the ICD-11 framework and serves as a platform to perform positive quality improvement in clinical practice. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  8. Clinician's Primer to ICD-10-CM Coding for Cleft Lip/Palate Care.

    PubMed

    Allori, Alexander C; Cragan, Janet D; Della Porta, Gina C; Mulliken, John B; Meara, John G; Bruun, Richard; Shusterman, Stephen; Cassell, Cynthia H; Raynor, Eileen; Santiago, Pedro; Marcus, Jeffrey R

    2017-01-01

    On October 1, 2015, the United States required use of the Clinical Modification of the International Classification of Diseases, 10th Revision (ICD-10-CM) for diagnostic coding. This primer was written to assist the cleft care community with understanding and use of ICD-10-CM for diagnostic coding related to cleft lip and/or palate (CL/P).

  9. Catalytic dehydrofluorination of 1,1,1,3,3-pentafluoropropane to 1,3,3,3-tetrafluoropropene over fluorinated NiO/Cr2O3 catalysts

    NASA Astrophysics Data System (ADS)

    Luo, Jian-Wei; Song, Jian-Dong; Jia, Wen-Zhi; Pu, Zhi-Ying; Lu, Ji-Qing; Luo, Meng-Fei

    2018-03-01

    Catalytic dehydrofluorination of 1,1,1,3,3-pentafluoropropane to 1,3,3,3-tetrafluoropropene was performed on a series of fluorinated NiO/Cr2O3 catalysts. The NiO/Cr2O3 catalysts were more active than the Cr2O3 because the new acid sites provided by NiF2 had higher turnover frequencies (9.43 × 10-3 - 12.08 × 10-3 s-1) than those on the Cr2O3 (4.55 × 10-3 s-1). Also, the NiO/Cr2O3 was more stable than the Cr2O3 due to its lower density of surface acid sites, which alleviated the coke deposition on the catalyst as evidenced by the Raman spectroscopic results. The kinetic results revealed that the15NiO/Cr2O3 had much lower activation energy (63.6 ± 4.5 kJ mol-1) than the Cr2O3 (127.6 ± 3.8 kJ mol-1). Accordingly, different reaction pathways on the two catalysts were proposed, which involved the cleavage of the Csbnd F and Csbnd H bonds on the surface acid and base sites, respectively.

  10. Site identity and importance in cosubstituted bixbyite In 2O 3

    DOE PAGES

    Rickert, Karl; Harris, Jeremy; Sedefoglu, Nazmi; ...

    2017-02-09

    The bixbyite structure of In 2O 3 has two nonequivalent, 6-coordinate cation sites and, when Sn is doped into In 2O 3, the Sn prefers the “b-site” and produces a highly conductive material. When divalent/tetravalent cation pairs are cosubstituted into In 2O 3, however, the conductivity increases to a lesser extent and the site occupancy is less understood. We examine the site occupancy in the Mg xIn 2–2xSn xO 3 and Zn xIn 2–2xSn xO 3 systems with high resolution X-ray and neutron diffraction and density functional theory computations, respectively. In these sample cases and those that are previously reportedmore » in the M xIn 2–2xSn xO 3 (M = Cu, Ni, or Zn) systems, the solubility limit is greater than 25%, ensuring that the b-site cannot be the exclusively preferred site as it is in Sn:In 2O 3. Prior to this saturation point, we report that the M 2+ cation always has at least a partial occupancy on the d-site and the Sn 4+ cation has at least a partial occupancy on the b-site. The energies of formation for these configurations are highly favored, and prefer that the divalent and tetravalent substitutes are adjacent in the crystal lattice, which suggests short range ordering. Diffuse reflectance and 4-point probe measurements of Mg xIn 2–xSn xO 3 demonstrate that it can maintain an optical band gap >2.8 eV while surpassing 1000 S/cm in conductivity. Furthermore, understanding how multiple constituents occupy the two nonequivalent cation sites can provide information on how to optimize cosubstituted systems to increase Sn solubility while maintaining its dopant nature, achieving maximum conductivity.« less

  11. Site identity and importance in cosubstituted bixbyite In 2O 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rickert, Karl; Harris, Jeremy; Sedefoglu, Nazmi

    The bixbyite structure of In 2O 3 has two nonequivalent, 6-coordinate cation sites and, when Sn is doped into In 2O 3, the Sn prefers the “b-site” and produces a highly conductive material. When divalent/tetravalent cation pairs are cosubstituted into In 2O 3, however, the conductivity increases to a lesser extent and the site occupancy is less understood. We examine the site occupancy in the Mg xIn 2–2xSn xO 3 and Zn xIn 2–2xSn xO 3 systems with high resolution X-ray and neutron diffraction and density functional theory computations, respectively. In these sample cases and those that are previously reportedmore » in the M xIn 2–2xSn xO 3 (M = Cu, Ni, or Zn) systems, the solubility limit is greater than 25%, ensuring that the b-site cannot be the exclusively preferred site as it is in Sn:In 2O 3. Prior to this saturation point, we report that the M 2+ cation always has at least a partial occupancy on the d-site and the Sn 4+ cation has at least a partial occupancy on the b-site. The energies of formation for these configurations are highly favored, and prefer that the divalent and tetravalent substitutes are adjacent in the crystal lattice, which suggests short range ordering. Diffuse reflectance and 4-point probe measurements of Mg xIn 2–xSn xO 3 demonstrate that it can maintain an optical band gap >2.8 eV while surpassing 1000 S/cm in conductivity. Furthermore, understanding how multiple constituents occupy the two nonequivalent cation sites can provide information on how to optimize cosubstituted systems to increase Sn solubility while maintaining its dopant nature, achieving maximum conductivity.« less

  12. Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts.

    PubMed

    Ploux, Sylvain; Swerdlow, Charles D; Strik, Marc; Welte, Nicolas; Klotz, Nicolas; Ritter, Philippe; Haïssaguerre, Michel; Bordachar, Pierre

    2018-06-02

    Recognition of implantable cardioverter defibrillator (ICD) lead malfunction before occurrence of life threatening complications is crucial. We aimed to assess the effectiveness of remote monitoring associated or not with a lead noise alert for early detection of ICD lead failure. From October 2013 to April 2017, a median of 1,224 (578-1,958) ICD patients were remotely monitored with comprehensive analysis of all transmitted materials. ICD lead failure and subsequent device interventions were prospectively collected in patients with (RMLN) and without (RM) a lead noise alert (Abbott Secure Sense™ or Medtronic Lead Integrity Alert™) in their remote monitoring system. During a follow-up of 4,457 patient years, 64 lead failures were diagnosed. Sixty-one (95%) of the diagnoses were made before any clinical complication occurred. Inappropriate shocks were delivered in only one patient of each group (3%), with an annual rate of 0.04%. All high voltage conductor failures were identified remotely by a dedicated impedance alert in 10 patients. Pace-sense component failures were correctly identified by a dedicated alert in 77% (17 of 22) of the RMLN group versus 25% (8 of 32) of the RM group (P = 0.002). The absence of a lead noise alert was associated with a 16-fold increase in the likelihood of initiating either a shock or ATP (OR: 16.0, 95% CI 1.8-143.3; P = 0.01). ICD remote monitoring with systematic review of all transmitted data is associated with a very low rate of inappropriate shocks related to lead failure. Dedicated noise alerts further reduce inappropriate detection of ventricular arrhythmias. © 2018 Wiley Periodicals, Inc.

  13. Increased confidence to engage in physical exertion: older ICD recipients' experiences of participating in an exercise training programme.

    PubMed

    Morken, Ingvild Margreta; Norekvål, Tone M; Isaksen, Kjetil; Munk, Peter S; Karlsen, Bjørg; Larsen, Alf I

    2013-06-01

    Research suggests that exercise training (ET) programmes may improve both physical and psychosocial functioning in implantable cardioverter defibrillator (ICD) recipients. Most of this research has been conducted by means of quantitative methods. However, knowledge of older ICD recipients' experiences of participating in such programmes is sparse. There is thus a need for more detailed qualitative data from the perspective of older patients. To describe older ICD recipients' experiences of participating in an ET programme. A qualitative design with semistructured interviews involving 12 older ICD recipients who had participated in a 3-month ET programme. Mini-disc recordings of the interviews were transcribed verbatim and analysed using content analysis. The analysis revealed two major themes: (1) 'increased confidence to engage in physical exertion'; and (2) 'increased satisfaction with life'. The first theme is illustrated by three subthemes: 'perceived support from physiotherapists', 'perceiving the heart rate monitor as a motivation to exercise', and 'perceiving peers as motivators for enjoyment and making the effort to exercise'. The second theme was illustrated by the following subthemes: 'perceived psychosocial benefits', 'perceived physical benefits', and 'exercise as a new health habit'. The findings indicate that exercising in a cardiac rehabilitation centre together with peers and supervised by skilled healthcare professionals may increase motivation to exert oneself, leading to emotional and physical benefits as well as a more social and active lifestyle for older ICD recipients.

  14. T-wave loop area from a pre-implant 12-lead ECG is associated with appropriate ICD shocks

    PubMed Central

    Hnatkova, Katerina; Friede, Tim; Malik, Marek; Zabel, Markus

    2017-01-01

    Aims In implantable cardioverter-defibrillator (ICD) patients, predictors of ICD shocks and mortality are needed to improve patient selection. Electrocardiographic (ECG) markers are simple to obtain and have been demonstrated to predict mortality. We aimed to assess the association of T-wave loop area and circularity with ICD shocks. Methods The study investigated patients with ICDs implanted between 1998 and 2010 for whom digital 12-lead ECGs (Schiller CS200 ECG-Network) of sufficient quality were obtained within 1 month prior to the implantation. T-wave loop area and circularity were calculated. Follow-up data of appropriate shocks were obtained during ICD clinic visits that included reviews of device stored electrograms. Results A total of 605 patients (82% males) were included; 68% had ischemic cardiomyopathy and 72% were treated for primary prevention. Over 3.8±1.4 years of follow-up, 114 patients (19%) experienced appropriate shock(s). Those with smaller T-wave loop area received fewer shocks (TLA, hazard ratio, HR, per increase of 1 technical unit, 0.71; [95% confidence interval, 0.53–0.94]; P = 0.02) and those with larger T-wave loop circularity (TLC) representing rounder T wave loop received more shocks (HR per 1% TLC increase 2.96; [0.85–10.36]; P = 0.09). When the quartile containing the largest TLA and TLC values, respectively, were compared to the remaining cases, TLA remained significantly associated with fewer and TLC with more frequent shocks also after multivariate adjustment for clinical variables (HR, 0.59 [0.35–0.99], P = 0.044; and 1.64 [1.08–2.49], P = 0.021, respectively). Conclusions The size and shape of the T-wave loop calculated from pre-implantation 12-lead ECGs are associated with appropriate ICD shocks. PMID:28291831

  15. DSM-5 AND ICD-11 DEFINITIONS OF POSTTRAUMATIC STRESS DISORDER: INVESTIGATING “NARROW” AND “BROAD” APPROACHES

    PubMed Central

    Stein, Dan J.; McLaughlin, Katie A.; Koenen, Karestan C.; Atwoli, Lukoye; Friedman, Matthew J.; Hill, Eric D.; Maercker, Andreas; Petukhova, Maria; Shahly, Victoria; van Ommeren, Mark; Alonso, Jordi; Borges, Guilherme; de Girolamo, Giovanni; de Jonge, Peter; Demyttenaere, Koen; Florescu, Silvia; Karam, Elie G.; Kawakami, Norito; Matschinger, Herbert; Okoliyski, Michail; Posada-Villa, Jose; Scott, Kate M.; Viana, Maria Carmen; Kessler, Ronald C.

    2014-01-01

    Background The development of the Diagnostic and Statistical Manual of Mental Disorders 5th edition (DSM-5) and ICD-11 has led to reconsideration of diagnostic criteria for posttraumatic stress disorder (PTSD). The World Mental Health (WMH) Surveys allow investigation of the implications of the changing criteria compared to DSM-IV and ICD-10. Methods WMH Surveys in 13 countries asked respondents to enumerate all their lifetime traumatic events (TEs) and randomly selected one TE per respondent for PTSD assessment. DSMIV and ICD-10 PTSD were assessed for the 23,936 respondents who reported lifetime TEs in these surveys with the fully structured Composite International Diagnostic Interview (CIDI). DSM-5 and proposed ICD-11 criteria were approximated. Associations of the different criteria sets with indicators of clinical severity (distress-impairment, suicidality, comorbid fear-distress disorders, PTSD symptom duration) were examined to investigate the implications of using the different systems. Results A total of 5.6% of respondents met criteria for “broadly defined” PTSD (i.e., full criteria in at least one diagnostic system), with prevalence ranging from 3.0% with DSM-5 to 4.4% with ICD-10. Only one-third of broadly defined cases met criteria in all four systems and another one third in only one system (narrowly defined cases). Between-system differences in indicators of clinical severity suggest that ICD-10 criteria are least strict and DSM-IV criteria most strict. The more striking result, though, is that significantly elevated indicators of clinical significance were found even for narrowly defined cases for each of the four diagnostic systems. Conclusions These results argue for a broad definition of PTSD defined by any one of the different systems to capture all clinically significant cases of PTSD in future studies. PMID:24894802

  16. Comparison of ICD-9-based, retrospective, and prospective assessments of perioperative complications: assessment of accuracy in reporting.

    PubMed

    Campbell, Peter G; Malone, Jennifer; Yadla, Sanjay; Chitale, Rohan; Nasser, Rani; Maltenfort, Mitchell G; Vaccaro, Alex; Ratliff, John K

    2011-01-01

    large studies of ICD-9-based complication and hospital-acquired condition (HAC) chart reviews have not been validated through a comparison with prospective assessments of perioperative adverse event occurrence. Retrospective chart review, while generally assumed to underreport complication occurrence, has not been subjected to prospective study. It is unclear whether ICD-9-based population studies are more accurate than retrospective reviews or are perhaps equally susceptible to bias. To determine the validity of an ICD-9-based assessment of perioperative complications, the authors compared a prospective independent evaluation of such complications with ICD-9-based HAC data in a cohort of patients who underwent spine surgery. For further comparison, a separate retrospective review of the same cohort of patients was completed as well. a prospective assessment of complications in spine surgery over a 6-month period (May to December 2008) was completed using an independent auditor and a validated definition of perioperative complications. The auditor maintained a prospective database, which included complications occurring in the initial 30 days after surgery. All medical adverse events were included in the assessment. All patients undergoing spine surgery during the study period were eligible for inclusion; the only exclusionary criterion used was the availability of the auditor for patient assessment. From the overall patient database, 100 patients were randomly extracted for further review; in these patients ICD-9-based HAC data were obtained from coder data. Separately, a retrospective assessment of complication incidence was completed using chart and electronic medical record review. The same definition of perioperative adverse events and the inclusion of medical adverse events were applied in the prospective, ICD-9-based, and retrospective assessments. ninety-two patients had adequate records for the ICD-9 assessment, whereas 98 patients had adequate chart

  17. The 1-month prevalence of generalized anxiety disorder according to DSM-IV, DSM-V, and ICD-10 among nondemented 75-year-olds in Gothenburg, Sweden.

    PubMed

    Nilsson, Johan; Östling, Svante; Waern, Margda; Karlsson, Björn; Sigström, Robert; Guo, Xinxin; Skoog, Ingmar

    2012-11-01

    To examine the 1-month prevalence of generalized anxiety disorder (GAD) according to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), Diagnostic and Statistical Manual of Mental, Fifth Edition (DSM-V), and International Classification of Diseases, Tenth Revision (ICD-10), and the overlap between these criteria, in a population sample of 75-year-olds. We also aimed to examine comorbidity between GAD and other psychiatric diagnoses, such as depression. During 2005-2006, a comprehensive semistructured psychiatric interview was conducted by trained nurses in a representative population sample of 75-year-olds without dementia in Gothenburg, Sweden (N = 777; 299 men and 478 women). All psychiatric diagnoses were made according to DSM-IV. GAD was also diagnosed according to ICD-10 and DSM-V. The 1-month prevalence of GAD was 4.1% (N = 32) according to DSM-IV, 4.5% (N = 35) according to DSM-V, and 3.7% (N = 29) according to ICD-10. Only 46.9% of those with DSM-IV GAD fulfilled ICD-10 criteria, and only 51.7% and 44.8% of those with ICD-10 GAD fulfilled DSM-IV/V criteria. Instead, 84.4% and 74.3% of those with DSM-IV/V GAD and 89.7% of those with ICD-10 GAD had depression. Also other psychiatric diagnoses were common in those with ICD-10 and DSM-IV GAD. Only a small minority with GAD, irrespective of criteria, had no other comorbid psychiatric disorder. ICD-10 GAD was related to an increased mortality rate. While GAD was common in 75-year-olds, DSM-IV/V and ICD-10 captured different individuals. Current definitions of GAD may comprise two different expressions of the disease. There was greater congruence between GAD in either classification system and depression than between DSM-IV/V GAD and ICD-10 GAD, emphasizing the close link between these entities. 2012 American Association for Geriatric Psychiatry

  18. Assessment of community contribution to the ICDS scheme in district Agra: a case study.

    PubMed

    Nayar, D; Kapil, U; Nandan, D

    1999-01-01

    This study was conducted to assess community contribution to the Integrated Child Development Services (ICDS) program, which promotes mother and child health in the Agra district, Uttar Pradesh, India. Three rural ICDS projects in the district were selected, out of which a total of 74 Anganwadi centers (AWCs) were chosen for the study. The Anganwadi workers (AWWs) were interviewed through a semi-structured questionnaire to assess the community¿s contribution during the previous 6 months. Results revealed that about 68% of AWWs had been able to receive assistance in bringing the children to the AWC. 53.3% had received free accommodation for AWC, and 42.6% had obtained assistance in implementation of health activities. Only 4% and 12% of the AWWs reported community assistance in the preparation and distribution of nutritional supplements, respectively. There had been no contribution received in terms of raw food for supplementary nutrition and fuel for cooking. The study concludes that rural area free accommodation for the AWC and community assistance in bringing children to the AWC were the most common forms of community contribution to the ICDS program.

  19. Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.

    PubMed

    Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun

    2016-01-01

    Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.

  20. Three Diagnostic Systems for Autism: DSM-III, DSM-III-R, and ICD-10.

    ERIC Educational Resources Information Center

    Volkmar, Fred R.; And Others

    1992-01-01

    This paper compared clinicians' diagnosis and DSM-III (Diagnostic and Statistical Manual), DSM-III-R (Revised), and ICD-10 (International Classification of Diseases) diagnoses of 52 individuals with autism and 62 nonautistic, developmentally disordered individuals. The DSM-III-R system overdiagnosed the presence of autism, and ICD-10 closely…

  1. Deriving ICD-11 personality disorder domains from dsm-5 traits: initial attempt to harmonize two diagnostic systems.

    PubMed

    Bach, B; Sellbom, M; Kongerslev, M; Simonsen, E; Krueger, R F; Mulder, R

    2017-07-01

    The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. We examined (i) whether designated DSM-5 trait facets can be used to describe the proposed ICD-11 trait domains, and (ii) how these ICD-11 trait features are hierarchically organized. A mixed Danish derivation sample (N = 1541) of 615 psychiatric out-patients and 925 community participants along with a US replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized in the proposed ICD-11 five-domain structure as well as other recognizable higher-order models of personality and psychopathology. Model fits revealed that the five proposed ICD-11 personality disorder domains were satisfactorily resembled, and replicated in the independent US sample. The proposed ICD-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Wideband Arrhythmia-Insensitive-Rapid (AIR) Pulse Sequence for Cardiac T1 mapping without Image Artifacts induced by ICD

    PubMed Central

    Hong, KyungPyo; Jeong, Eun-Kee; Wall, T. Scott; Drakos, Stavros G.; Kim, Daniel

    2015-01-01

    Purpose To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). Methods We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz), in order to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5T. Results In 5 phantoms representing native myocardium and blood and post-contrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error >29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error <5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error >10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error <2.0%). Conclusion This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. PMID:25975192

  3. [Coding in general practice-Will the ICD-11 be a step forward?

    PubMed

    Kühlein, Thomas; Virtanen, Martti; Claus, Christoph; Popert, Uwe; van Boven, Kees

    2018-07-01

    Primary care physicians in Germany don't benefit from coding diagnoses-they are coding for the needs of others. For coding, they mostly are using either the thesaurus of the German Institute of Medical Documentation and Information (DIMDI) or self-made cheat-sheets. Coding quality is low but seems to be sufficient for the main use case of the resulting data, which is the morbidity adjusted risk compensation scheme that distributes financial resources between the many German health insurance companies.Neither the International Classification of Diseases and Health Related Problems (ICD-10) nor the German thesaurus as an interface terminology are adequate for coding in primary care. The ICD-11 itself will not recognizably be a step forward from the perspective of primary care. At least the browser database format will be advantageous. An implementation into the 182 different electronic health records (EHR) on the German market would probably standardize the coding process and make code finding easier. This method of coding would still be more cumbersome than the current coding with self-made cheat-sheets.The first steps towards a useful official cheat-sheet for primary care have been taken, awaiting implementation and evaluation. The International Classification of Primary Care (ICPC-2) already provides an adequate classification standard for primary care that can also be used in combination with ICD-10. A new version of ICPC (ICPC-3) is under development. As the ICPC-2 has already been integrated into the foundation layer of ICD-11 it might easily become the future standard for coding in primary care. Improving communication between the different EHR would make taking over codes from other healthcare providers possible. Another opportunity to improve the coding quality might be creating use cases for the resulting data for the primary care physicians themselves.

  4. A natural language based search engine for ICD10 diagnosis encoding.

    PubMed

    Baud, Robert

    2004-01-01

    We have developed a multiple step process for implementing an ICD10 search engine. The complexity of the task has been shown and we recommend collecting adequate expertise before starting any implementation. Underestimation of the expert time and inadequate data resources are probable reasons for failure. We also claim that when all conditions are met in term of resource and availability of the expertise, the benefits of a responsive ICD10 search engine will be present and the investment will be successful.

  5. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

    PubMed

    Healey, Jeff S; Dorian, Paul; Mitchell, L Brent; Talajic, Mario; Philippon, Francois; Simpson, Chris; Yee, Raymond; Morillo, Carlos A; Lamy, Andre; Basta, Magdy; Birnie, David H; Wang, Xiaoyin; Nair, Girish M; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2010-02-01

    There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

  6. Protein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).

    PubMed

    Cheng, Alan; Zhang, Yiyi; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Ellenbogen, Kenneth A; Dickfeld, Timm; Spragg, David D; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F

    2014-12-01

    Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. clinicaltrials.gov; Unique Identifier: NCT00733590. © 2014 American Heart Association, Inc.

  7. Obsessive compulsive and related disorders: comparing DSM-5 and ICD-11.

    PubMed

    Marras, Anna; Fineberg, Naomi; Pallanti, Stefano

    2016-08-01

    Obsessive-compulsive disorder (OCD) has been recognized as mainly characterized by compulsivity rather than anxiety and, therefore, was removed from the anxiety disorders chapter and given its own in both the American Psychiatric Association (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the Beta Draft Version of the 11th revision of the World Health Organization (WHO) International Classification of Diseases (ICD-11). This revised clustering is based on increasing evidence of common affected neurocircuits between disorders, differently from previous classification systems based on interrater agreement. In this article, we focus on the classification of obsessive-compulsive and related disorders (OCRDs), examining the differences in approach adopted by these 2 nosological systems, with particular attention to the proposed changes in the forthcoming ICD-11. At this stage, notable differences in the ICD classification are emerging from the previous revision, apparently converging toward a reformulation of OCRDs that is closer to the DSM-5.

  8. Persisting malnutrition in Chandigarh: decadal underweight trends and impact of ICDS program.

    PubMed

    Thakur, Jarnail Singh; Prinja, Shankar; Bhatia, Satpal Singh

    2011-04-01

    Decline in malnutrition levels has been dismal since the 1990s. We ascertained decadal trend in childhood nutritional status between 1997 and 2007 in Chandigarh, India and assessed impact of Integrated Child Development Services (ICDS) on childhood undernutrition. A total of 803 under-five children, 547 children between 12-23 months age, and 218 women with an infant child were recruited for the study. Findings of present study were compared with another methodologically similar study (1997) from Chandigarh and Reproductive and Child Health Rapid Household Survey (1998) to draw decadal trends. Prevalence of underweight among under-five children remained almost stagnant in the last one decade from 51.6%; (1997) to 50.4%; (2007). There was insignificant difference (P=0.3) in prevalence of underweight among children registered under ICDS program (52.1%;) and those not registered (48.4%;) in 2007. Other health and service provision indicators had mixed results in the past decade. Health services utilization was poorest in urban slums.

  9. How well do the DSM-5 alcohol use disorder designations map to the ICD-10 disorders?

    PubMed

    Hoffmann, Norman G; Kopak, Albert M

    2015-04-01

    The Diagnostic and Statistical Manual of Mental Disorders, 5th edition (DSM-5), and the International Statistical Classification of Diseases and Related Health Problems, 10th edition (ICD-10), both establish diagnostic criteria for alcohol use disorders. The dimensional severity perspective provided by the DSM-5 may overlap in important ways but also may diverge from the categorical harmful use versus dependence designations presented by the ICD-10. It is especially important to consider the convergence of these 2 diagnostic approaches as the DSM is widely used by clinicians, but the U.S. Centers for Medicare and Medicaid Services has recently required that providers bill for services using the ICD-10 designations. Data from 6,871 male and 801 female admissions to a state prison system were used to compare the DSM-5 severity index for alcohol use disorder to the ICD-10 clinical and research formulations for harmful use and dependence. The DSM-5 and the ICD-10 were highly convergent for the most severe alcohol use disorders and also for those who did not receive a diagnosis. Most DSM-5 moderate alcohol use disorder cases were classified as dependence cases under both the clinical and research ICD criteria. In contrast, there was much more variation in the DSM mild cases. These were divided into categories of harmful use or misuse, depending on whether the clinical or research ICD criteria were applied. Results were similar among male and female inmates. The DSM-5 and ICD-10 exhibit a high level of agreement for cases that would not receive a diagnosis as well as the most severe cases. However, there are important distinctions to be made between the 2 approaches for mild and moderate DSM disorders in addition to harmful use/misuse cases in the ICD. The cases influenced by these discrepancies are most likely to be affected by recently implemented service provider billing practices. Copyright © 2015 by the Research Society on Alcoholism.

  10. CADDIS Volume 5. Causal Databases: Interactive Conceptual Diagrams (ICDs)

    EPA Pesticide Factsheets

    In Interactive Conceptual Diagram (ICD) section of CADDIS allows users to create conceptual model diagrams, search a literature-based evidence database, and then attach that evidence to their diagrams.

  11. Epitaxial phase diagrams of SrTiO3, CaTiO3, and SrHfO3: Computational investigation including the role of antiferrodistortive and A -site displacement modes

    NASA Astrophysics Data System (ADS)

    Angsten, Thomas; Asta, Mark

    2018-04-01

    Ground-state epitaxial phase diagrams are calculated by density functional theory (DFT) for SrTiO3, CaTiO3, and SrHfO3 perovskite-based compounds, accounting for the effects of antiferrodistortive and A -site displacement modes. Biaxial strain states corresponding to epitaxial growth of (001)-oriented films are considered, with misfit strains ranging between -4 % and 4%. Ground-state structures are determined using a computational procedure in which input structures for DFT optimizations are identified as local minima in expansions of the total energy with respect to strain and soft-mode degrees of freedom. Comparison to results of previous DFT studies demonstrates the effectiveness of the computational approach in predicting ground-state phases. The calculated results show that antiferrodistortive octahedral rotations and associated A -site displacement modes act to suppress polarization and reduce the epitaxial strain energy. A projection of calculated atomic displacements in the ground-state epitaxial structures onto soft-mode eigenvectors shows that three ferroelectric and six antiferrodistortive displacement modes are dominant at all misfit strains considered, with the relative contributions from each varying systematically with the strain. Additional A -site displacement modes contribute to the atomic displacements in CaTiO3 and SrHfO3, which serve to optimize the coordination of the undersized A -site cation.

  12. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    PubMed

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P < 0.001). Four subjects (6%) passed screening using the ECG machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  13. Highly dispersed SiO x/Al 2O 3 catalysts illuminate the reactivity of isolated silanol sites

    DOE PAGES

    Mouat, Aidan R.; George, Cassandra; Kobayashi, Takeshi; ...

    2015-09-23

    The reaction of γ-alumina with tetraethylorthosilicate (TEOS) vapor at low temperatures selectively yields monomeric SiO x species on the alumina surface. These isolated (-AlO) 3Si(OH) sites are characterized by PXRD, XPS, DRIFTS of adsorbed NH 3, CO, and pyridine, and 29Si and 27Al DNP-enhanced solid-state NMR spectroscopy. The formation of isolated sites suggests that TEOS reacts preferentially at strong Lewis acid sites on the γ-Al 2O 3 surface, functionalizing the surface with “mild” Brønsted acid sites. As a result, for liquid-phase catalytic cyclohexanol dehydration, these SiO x sites exhibit up to 3.5-fold higher specific activity than the parent alumina withmore » identical selectivity.« less

  14. 42 CFR Appendix A to Part 81 - Glossary of ICD-9 Codes and Their Cancer Descriptions 1

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Glossary of ICD-9 Codes and Their Cancer.... 81, App. A Appendix A to Part 81—Glossary of ICD-9 Codes and Their Cancer Descriptions 1 ICD-9 code Cancer description 140 Malignant neoplasm of lip. 141 Malignant neoplasm of tongue. 142 Malignant...

  15. Wearable cardioverter defibrillator: a life vest till the life boat (ICD) arrives.

    PubMed

    Francis, Johnson; Reek, Sven

    2014-01-01

    It is well established that implantable cardioverter defibrillator (ICD) is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation of an ICD while the patient can still be at a risk of demise due to a life threatening ventricular arrhythmia. There could also be a temporary indication for protection while explanting an infected ICD system. The wearable cardioverter defibrillator (WCD) is a device which comes to the rescue in such situations. In this brief review, we discuss the historical aspects of the development of a WCD, technical aspects as well as the clinical trial data and real world scenario of its use. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. The Utility and Challenges of Using ICD Codes in Child Maltreatment Research: A Review of Existing Literature

    ERIC Educational Resources Information Center

    Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten

    2009-01-01

    Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…

  17. Reduced long-term overall mortality in heart failure patients with prolonged QRS treated with CRT combined with ICD vs. heart failure patients with narrow QRS treated with ICD only.

    PubMed

    Palmisano, Pietro; Accogli, Michele; Pisanò, Ennio Carmine Luigi; Zaccaria, Maria; De Blasi, Sergio; Ponzetta, Maria Antonietta; Valsecchi, Sergio; Milanese, Giovanni; Lauretti, Maurelio; Magliari, Francesco

    2016-09-01

    It is not known whether heart failure (HF) patients with prolonged QRS who undergo cardiac resynchronization therapy combined with a defibrillator (CRT-D) have a prognostic advantage over HF patients with narrow QRS (therefore without indication for CRT) treated with an implantable cardioverter defibrillator (ICD) only. The aim of this study was to compare the long-term mortality of a group of HF patients with prolonged QRS receiving CRT-D with that of a similar group of patients with narrow QRS receiving ICD only. A total of 312 patients (mean age 66 ± 13 years; 84% male, mean left ventricular ejection fraction 25 ± 4%, mean New York Heart Association class 2.6 ± 0.5) were included in the analysis. Of these, 138 with a QRS complex duration ≥120 ms received a CRT-D. During follow-up, the time and cause of death were assessed. During a median follow-up of 46 months, CRT-D patients showed significantly lower overall mortality (P = 0.038). Compared with patients receiving ICD only, CRT-D patients showed lower HF mortality (P = 0.003). Coronary mortality, non-cardiac mortality, and sudden mortality were similar in both groups (all P > 0.05). A positive response to CRT was an independent predictor of reduced mortality on multivariate analysis (hazard ratio: 0.27; P = 0.047). In HF patients treated with ICD, the subgroup of patients with prolonged QRS who receive CRT-D displays better long-term survival than narrow QRS ICD recipients, owing to their reduced HF mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Strategic Mobility 21 Initial Capabilities Document (ICD)

    DTIC Science & Technology

    2006-07-28

    MANDATORY ARCHITECTURE FRAMWORK DOCUMENT .......................................A-1 APPENDIX B: REFERENCES...Document July 27, 2006 JPPSP ICD Version 1.0 A-1 APPENDIX A: MANDATORY ARCHITECTURE FRAMWORK DOCUMENT Legend next page. Initial Capabilities...SM21 will combine several end-to-end Force Projection Process enablers. Some of the enablers described below are at the conceptual stage while others

  19. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort.

    PubMed

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C; Johansen, Jens B; Petersen, Helen H; Haarbo, Jens; Johansen, Martin B; Thøgersen, Anna Margrethe

    2016-03-01

    The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. The purpose of this study was to compare clinical outcomes in patients with single- and dual-coil leads. All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. Single-coil leads were associated with lower all-cause mortality with an adjusted hazard ratio of 0.85 (95% confidence interval 0.73-0.99; P = .04). This finding was robust in a supplementary propensity score-matched analysis. However, dual-coil leads were used in patients with slightly higher preimplant morbidity, making residual confounding by indication the most likely explanation for the observed association between lead type and mortality. The lowest successful defibrillation energy was higher using single-coil leads (23.2 ± 4.3 J vs 22.1 ± 3.9 J; P < .001). No significant differences were observed for other secondary end points showing high shock efficacies and low rates of lead failures and extraction complications. Shock efficacy is high for modern ICD systems. The choice between single-coil and dual-coil defibrillator leads is unlikely to have a clinically significant impact on patient outcomes in routine ICD implants. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Projected impact of the ICD-10-CM/PCS conversion on longitudinal data and the Joint Commission Core Measures.

    PubMed

    Fenton, Susan H; Benigni, Mary Sue

    2014-01-01

    The transition from ICD-9-CM to ICD-10-CM/PCS is expected to result in longitudinal data discontinuities, as occurred with cause-of-death in 1999. The General Equivalence Maps (GEMs), while useful for suggesting potential maps do not provide guidance regarding the frequency of any matches. Longitudinal data comparisons can only be reliable if they use comparability ratios or factors which have been calculated using records coded in both classification systems. This study utilized 3,969 de-identified dually coded records to examine raw comparability ratios, as well as the comparability ratios between the Joint Commission Core Measures. The raw comparability factor results range from 16.216 for Nicotine dependence, unspecified, uncomplicated to 118.009 for Chronic obstructive pulmonary disease, unspecified. The Joint Commission Core Measure comparability factor results range from 27.15 for Acute Respiratory Failure to 130.16 for Acute Myocardial Infarction. These results indicate significant differences in comparability between ICD-9-CM and ICD-10-CM code assignment, including when the codes are used for external reporting such as the Joint Commission Core Measures. To prevent errors in decision-making and reporting, all stakeholders relying on longitudinal data for measure reporting and other purposes should investigate the impact of the conversion on their data.

  1. Posttraumatic Stress Disorder and Complex Posttraumatic Stress Disorder in DSM-5 and ICD-11: Clinical and Behavioral Correlates.

    PubMed

    Hyland, Philip; Shevlin, Mark; Fyvie, Claire; Karatzias, Thanos

    2018-04-01

    The American Psychiatric Association and the World Health Organization provide distinct trauma-based diagnoses in the fifth edition of the Diagnostic and Statistical Manual (DSM-5), and the forthcoming 11th version of the International Classification of Diseases (ICD-11), respectively. The DSM-5 conceptualizes posttraumatic stress disorder (PTSD) as a single, broad diagnosis, whereas the ICD-11 proposes two "sibling" disorders: PTSD and complex PTSD (CPTSD). The objectives of the current study were to: (a) compare prevalence rates of PTSD/CPTSD based on each diagnostic system; (b) identify clinical and behavioral variables that distinguish ICD-11 CPTSD and PTSD diagnoses; and (c) examine the diagnostic associations for ICD-11 CPTSD and DSM-5 PTSD. Participants in a predominately female clinical sample (N = 106) completed self-report scales to measure ICD-11 PTSD and CPTSD, DSM-5 PTSD, and depression, anxiety, borderline personality disorder, dissociation, destructive behaviors, and suicidal ideation and self-harm. Significantly more people were diagnosed with PTSD according to the DSM-5 criteria (90.4%) compared to those diagnosed with PTSD and CPTSD according to the ICD-11 guidelines (79.8%). An ICD-11 CPTSD diagnosis was distinguished from an ICD-11 PTSD diagnosis by higher levels of dissociation (d = 1.01), depression (d = 0.63), and borderline personality disorder (d = 0.55). Diagnostic associations with depression, anxiety, and suicidal ideation and self-harm were higher for ICD-11 CPTSD compared to DSM-5 PTSD (by 10.7%, 4.0%, and 7.0%, respectively). These results have implications for differential diagnosis and for the development of targeted treatments for CPTSD. Copyright © 2018 International Society for Traumatic Stress Studies.

  2. In situ DRIFTS study of O3 adsorption on CaO, γ-Al2O3, CuO, α-Fe2O3 and ZnO at room temperature for the catalytic ozonation of cinnamaldehyde

    NASA Astrophysics Data System (ADS)

    Wu, Jianfeng; Su, Tongming; Jiang, Yuexiu; Xie, Xinling; Qin, Zuzeng; Ji, Hongbing

    2017-08-01

    In situ DRIFTS were conducted to identify adsorbed ozone and/or adsorbed oxygen species on CaO, ZnO, γ-Al2O3, CuO and α-Fe2O3 surfaces at room temperature. Samples were characterized by means of TG, XRD, N2 adsorption-desorption, pyridine-IR, nitrobenzene-IR, chloroform-IR, and CO2-TPD. Pyridine-DRIFTS measurements evidence two kinds of acid sites in all the samples. Nitrobenzene, chloroform-DRIFTS, and CO2-TPD reveal that there are large amounts of medium-strength base sites on all the metal oxides, and only CaO, ZnO, and γ-Al2O3 have strong base sites. And the benzaldehyde selectivity was increased in the same order of the alkalinity of the metal oxides. With weaker sites, ozone molecules form coordinative complexes bound via the terminal oxygen atom, observed by vibrational frequencies at 2095-2122 and 1026-1054 cm-1. The formation of ozonide O3- at 790 cm-1, atomic oxygen at 1317 cm-1, and superoxide O2- at 1124 cm-1 was detected; these species are believed to be intermediates of O3 decomposition on strong acid/base sites. The adsorption of ozone on metal oxides is a weak adsorption, and other gases, such as CO2, will compete with O3 adsorption. The mechanism of cinnamaldehyde ozonation at room temperature over CaO shows that cinnamaldehyde can not only be oxidized into cinnamic acid, but also be further oxidized into benzaldehyde, benzoic acid, maleic anhydride, and ultimately mineralized to CO2 in the presence of O3.

  3. Predictive Validity of ICD-11 PTSD as Measured by the Impact of Event Scale-Revised: A 15-Year Prospective Study of Political Prisoners.

    PubMed

    Hyland, Philip; Brewin, Chris R; Maercker, Andreas

    2017-04-01

    The 11 th edition of the International Classification of Diseases (ICD-11; World Health Organization, 2017) proposes a model of posttraumatic stress disorder (PTSD) that includes 6 symptoms. This study assessed the ability of a classification-independent measure of posttraumatic stress symptoms, the Impact of Event Scale-Revised (Weiss & Marmar, 1996), to capture the ICD-11 model of PTSD. The current study also provided the first assessment of the predictive validity of ICD-11 PTSD. Former East German political prisoners were assessed in 1994 (N = 144) and in 2008-2009 (N = 88) on numerous psychological variables using self-report measures. Of the participants, 48.2% and 36.8% met probable diagnosis for ICD-11 PTSD at the first and second assessments, respectively. Confirmatory factor analysis supported the factorial validity of the 3-factor ICD-11 model of PTSD, as represented by items selected from the Impact of Event Scale-Revised. Hierarchical multiple regression analysis demonstrated that, controlling for sex, the symptom clusters of ICD-11 PTSD (reexperiencing, avoidance, and sense of threat) significantly contributed to the explanation of depression (R 2 = .17), quality of life (R 2 = .21), internalized anger (R 2 = .10), externalized anger (R 2 = .12), hatred of perpetrators (R 2 = .15), dysfunctional disclosure (R 2 = .27), and social acknowledgment as a victim (R 2 = .12) across the 15-year study period. Current findings add support for the factorial and predictive validity of ICD-11 PTSD within a unique cohort of political prisoners. Copyright © 2017 International Society for Traumatic Stress Studies.

  4. A comparison of DSM-III-R and ICD-10 personality disorder criteria in an out-patient population.

    PubMed

    Sara, G; Raven, P; Mann, A

    1996-01-01

    This study reports the results of a comparison of DSM-III-R and ICD-10 personality disorder criteria by application of both sets of criteria to the same group of patients. Despite the clinical relevance of these disorders and the need for reliable diagnostic criteria, such a comparison has not previously been reported. DSM-III-R and ICD-10 have converged in their classification of personality disorders, but some important differences between the two systems remain. Personality disorder diagnoses from both systems were obtained in 52 out-patients, using the Standardized Assessment of Personality (SAP), a brief, informant-based interview which yields diagnoses in both DSM-III-R and ICD-10. For individual personality disorder diagnoses, agreement between systems was limited. Thirty-four subjects received a personality disorder diagnosis that had an equivalent form in both systems, but only 10 subjects (29%) received the same primary diagnosis in each system. There was a difference in rate of diagnosis, with ICD-10 making significantly more personality disorder diagnoses. The lower diagnostic threshold of the ICD-10 contributed most of this effect. Further modifications in ICD-10 Diagnostic Criteria for Research (DCR) and DSM-IV to the personality disorder category have been considered. The omission in DSM-IV of three categories unique to that system and the raising of the threshold in ICD-10 DCR, do seem to have been helpful in promoting convergence.

  5. Proposals for Paraphilic Disorders in the International Classification of Diseases and Related Health Problems, Eleventh Revision (ICD-11).

    PubMed

    Krueger, Richard B; Reed, Geoffrey M; First, Michael B; Marais, Adele; Kismodi, Eszter; Briken, Peer

    2017-07-01

    The World Health Organization is currently developing the 11th revision of the International Classifications of Diseases and Related Health Problems (ICD-11), with approval of the ICD-11 by the World Health Assembly anticipated in 2018. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH) was created and charged with reviewing and making recommendations for categories related to sexuality that are contained in the chapter of Mental and Behavioural Disorders in ICD-10 (World Health Organization 1992a). Among these categories was the ICD-10 grouping F65, Disorders of sexual preference, which describes conditions now widely referred to as Paraphilic Disorders. This article reviews the evidence base, rationale, and recommendations for the proposed revisions in this area for ICD-11 and compares them with DSM-5. The WGSDSH recommended that the grouping, Disorders of sexual preference, be renamed to Paraphilic Disorders and be limited to disorders that involve sexual arousal patterns that focus on non-consenting others or are associated with substantial distress or direct risk of injury or death. Consistent with this framework, the WGSDSH also recommended that the ICD-10 categories of Fetishism, Fetishistic Transvestism, and Sadomasochism be removed from the classification and new categories of Coercive Sexual Sadism Disorder, Frotteuristic Disorder, Other Paraphilic Disorder Involving Non-Consenting Individuals, and Other Paraphilic Disorder Involving Solitary Behaviour or Consenting Individuals be added. The WGSDSH's proposals for Paraphilic Disorders in ICD-11 are based on the WHO's role as a global public health agency and the ICD's function as a public health reporting tool.

  6. Site Occupancies, Luminescence, and Thermometric Properties of LiY9(SiO4)6O2:Ce3+ Phosphors.

    PubMed

    Zhou, Weijie; Pan, Fengjuan; Zhou, Lei; Hou, Dejian; Huang, Yan; Tao, Ye; Liang, Hongbin

    2016-10-04

    In this work, we report the tunable emission properties of Ce 3+ in an apatite-type LiY 9 (SiO 4 ) 6 O 2 compound via adjusting the doping concentration or temperature. The occupancies of Ce 3+ ions at two different sites (Wyckoff 6h and 4f sites) in LiY 9 (SiO 4 ) 6 O 2 have been determined by Rietveld refinements. Two kinds of Ce 3+ f-d transitions have been studied in detail and then assigned to certain sites. The effects of temperature and doping concentration on Ce 3+ luminescence properties have been systematically investigated. It is found that the Ce 3+ ions prefer occupying Wyckoff 6h sites and the energy transfer between Ce 3+ at two sites becomes more efficient with an increase in doping concentration. In addition, the charge-transfer vibronic exciton (CTVE) induced by the existence of free oxygen ion plays an important role in the thermal quenching of Ce 3+ at 6h sites. Because of the tunable emissions from cyan to blue with increasing temperature, the phosphors LiY 9 (SiO 4 ) 6 O 2 :Ce 3+ are endowed with possible thermometric applications.

  7. Quantifying medical student clinical experiences via an ICD Code Logging App.

    PubMed

    Rawlins, Fred; Sumpter, Cameron; Sutphin, Dean; Garner, Harold R

    2018-03-01

    The logging of ICD Diagnostic, Procedure and Drug codes is one means of tracking the experience of medical students' clinical rotations. The goal is to create a web-based computer and mobile application to track the progress of trainees, monitor the effectiveness of their training locations and be a means of sampling public health status. We have developed a web-based app in which medical trainees make entries via a simple and quick interface optimized for both mobile devices and personal computers. For each patient interaction, users enter ICD diagnostic, procedure, and drug codes via a hierarchical or search entry interface, as well as patient demographics (age range and gender, but no personal identifiers), and free-text notes. Users and administrators can review and edit input via a series of output interfaces. The user interface and back-end database are provided via dual redundant failover Linux servers. Students master the interface in ten minutes, and thereafter complete entries in less than one minute. Five hundred-forty 3rd year VCOM students each averaged 100 entries in the first four week clinical rotation. Data accumulated in various Appalachian clinics and Central American medical mission trips has demonstrated the public health surveillance utility of the application. PC and mobile apps can be used to collect medical trainee experience in real time or near real-time, quickly, and efficiently. This system has collected 75,596 entries to date, less than 2% of trainees have needed assistance to become proficient, and medical school administrators are using the various summaries to evaluate students and compare different rotation sites. Copyright © 2017. Published by Elsevier B.V.

  8. Integrated Child Development Services (ICDS): harbinger of safe motherhood and child development.

    PubMed

    Lal, S

    1993-01-01

    Editorial comment was provided on the features that made the Integrated Child Development Services (ICDS) program in India unique and on whether or not the system could focus on younger age groups (e.g., 2-3 years of age). As part of a worldwide effort, India's ICDS program has been directed to human resource development. Over the past 17 years, the program has expanded to include almost 50% of the country's most vulnerable and deprived population. The focus on children aimed to improve their nutrition and health by reducing the incidence of morbidity, mortality, malnutrition, and school dropouts. The concern encompassed physical, social, and psychological development. The focus on mothers stressed enabling them to better care for the health and nutrition of their children. The program included prenatal care, safe delivery, and post natal concern for lactation, breast feeding, and physical growth monitoring in the early years. The program's unique features were its voluntary membership of community health workers, integrated services, and targeted coverage of economically weaker and deprived populations during critical child development periods. Indigenous Indian resources provided the primary financial support. Nation coverage was given for universal immunization, family welfare, child and maternal health, diarrheal disease control, vitamin A supplementation, and anemia screening and treatment. The multisectoral nature of the program has been realized at the village, sector, block, and district levels with linkages within Health, Education, and Social Welfare sectors, and with the Medical Colleges and Home Science Colleges. Feedback from operations research studies and other research activities was provided at the local program level, and interactions occurred between students in training programs and health care delivery systems. The program will be expanded to include the entire country. Health and nutrition education were considered the weakest part of ICDS

  9. Validity of registration of ICD codes and prescriptions in a research database in Swedish primary care: a cross-sectional study in Skaraborg primary care database

    PubMed Central

    2010-01-01

    Background In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. Methods SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). Results For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease. The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Conclusions Since the frequency of ICD code registration varies

  10. Validity of registration of ICD codes and prescriptions in a research database in Swedish primary care: a cross-sectional study in Skaraborg primary care database.

    PubMed

    Hjerpe, Per; Merlo, Juan; Ohlsson, Henrik; Bengtsson Boström, Kristina; Lindblad, Ulf

    2010-04-23

    In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease.The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Since the frequency of ICD code registration varies between different diagnoses, each

  11. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data

    PubMed Central

    Jolley, Rachel J; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-01-01

    Objective Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. Setting and participants All adults (aged ≥18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Research design Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Measures Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Results Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. Conclusions This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. PMID:26700284

  12. Validation and optimisation of an ICD-10-coded case definition for sepsis using administrative health data.

    PubMed

    Jolley, Rachel J; Quan, Hude; Jetté, Nathalie; Sawka, Keri Jo; Diep, Lucy; Goliath, Jade; Roberts, Derek J; Yipp, Bryan G; Doig, Christopher J

    2015-12-23

    Administrative health data are important for health services and outcomes research. We optimised and validated in intensive care unit (ICU) patients an International Classification of Disease (ICD)-coded case definition for sepsis, and compared this with an existing definition. We also assessed the definition's performance in non-ICU (ward) patients. All adults (aged ≥ 18 years) admitted to a multisystem ICU with general medicosurgical ICU care from one of three tertiary care centres in the Calgary region in Alberta, Canada, between 1 January 2009 and 31 December 2012 were included. Patient medical records were randomly selected and linked to the discharge abstract database. In ICU patients, we validated the Canadian Institute for Health Information (CIHI) ICD-10-CA (Canadian Revision)-coded definition for sepsis and severe sepsis against a reference standard medical chart review, and optimised this algorithm through examination of other conditions apparent in sepsis. Sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were calculated. Sepsis was present in 604 of 1001 ICU patients (60.4%). The CIHI ICD-10-CA-coded definition for sepsis had Sn (46.4%), Sp (98.7%), PPV (98.2%) and NPV (54.7%); and for severe sepsis had Sn (47.2%), Sp (97.5%), PPV (95.3%) and NPV (63.2%). The optimised ICD-coded algorithm for sepsis increased Sn by 25.5% and NPV by 11.9% with slightly lowered Sp (85.4%) and PPV (88.2%). For severe sepsis both Sn (65.1%) and NPV (70.1%) increased, while Sp (88.2%) and PPV (85.6%) decreased slightly. This study demonstrates that sepsis is highly undercoded in administrative data, thus under-ascertaining the true incidence of sepsis. The optimised ICD-coded definition has a higher validity with higher Sn and should be preferentially considered if used for surveillance purposes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go

  13. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation.

    PubMed

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S; van Hout, Moniek; Scholten, Marcoen; van der Palen, Job

    2013-09-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD). We examined associations between previous anxiety and depressive disorder, type D personality, anxiety or depressive symptoms, and health status in ICD patients prior to ICD implantation. Patients (N = 278; 83 % men; mean age = 62.2 years ±11) receiving a first ICD from September 2007 through April 2010 at the Medisch Spectrum Twente, The Netherlands completed validated questionnaires before implantation assessing type D personality (14-item Type D Scale), anxiety and depressive symptoms (Hospital Anxiety and Depression Scale), and health status (36-item Short Form Health Survey). History of anxiety or depressive disorder was assessed with the Mini International Neuropsychiatric Interview structural interview. Previous anxiety or depressive disorder was prevalent in 8 and 19 % of patients, respectively. Type D personality was present in 21 %, depressive symptoms in 15 %, and anxiety in 24 %. In adjusted analyses, type D personality was a dominant correlate of previous depressive disorder (odds ratio (OR) 6.2, p < 0.001) and previous anxiety disorder (OR 3.9, p = 0.004). Type D personality (OR 4.0, p < 0.001), age (OR 1.03, p = 0.043), and gender (OR 2.5, p = 0.013) were associated with anxiety symptoms at baseline. Type D personality (OR 5.9. p < 0.001) was also associated with increased depressive symptoms at baseline. Heart failure and type D personality were related to poorer health status. In ICD patients, prior to ICD implantation, a previous anxiety or depressive disorder, type D personality, and anxiety and depressive symptoms were associated with poorer health status. Type D personality was also independently associated with increased anxiety and depression symptoms.

  14. Psychological adaptation to ICDs and the influence of anxiety sensitivity.

    PubMed

    Lemon, Jim; Edelman, Sarah

    2007-03-01

    Forty-nine patients scheduled for implantable cardioverter defibrillator (ICD) implantation completed self-report psychological questionnaires prior to surgery and at 2, 4 and 6 months after surgery. The most common psychological problem identified was anxiety, with clinically significant cases based on the Depression Anxiety and Stress Scale (DASS) ranging between 26% and 34%. Clinically significant depression ranged between 8% and 20%. Anxiety sensitivity was associated with high levels of anxiety, depression and stress at baseline, but not at follow-up assessments. It is possible that within this population anxiety sensitivity is associated with distress during high-threat situations, but the relationship diminishes once the threat has passed. In addition, the reassurance provided by the ICD may reduce negative perceptions of symptoms, promoting psychological adaptation.

  15. CIM explorer--intelligent tool for exploring the ICD Romanian version.

    PubMed

    Filip, F; Haras, C

    2000-01-01

    The CIM Explorer software provides us with an intelligent interface for exploring the Romanian version of the International Classification of Diseases (in Romanian Clasificarea Internationala a Maladiilor-CIM). The ICD was transposed from its initial appearance as a printed document into a database. The classification can be accessed in two modes: "Navigation" and "Code" and queried in the "Key words" mode. In the last mode CIM Explorer program searches for the right content of the ICD records starting from naturally written expressions which it "understands". As a results it returns all the records containing the key words regardless their grammatical form. This program implements the specificity of the Romanian language where the words are made up from a root and a flexional termination.

  16. ISS mapped from ICD-9-CM by a novel freeware versus traditional coding: a comparative study.

    PubMed

    Di Bartolomeo, Stefano; Tillati, Silvia; Valent, Francesca; Zanier, Loris; Barbone, Fabio

    2010-03-31

    Injury severity measures are based either on the Abbreviated Injury Scale (AIS) or the International Classification of diseases (ICD). The latter is more convenient because routinely collected by clinicians for administrative reasons. To exploit this advantage, a proprietary program that maps ICD-9-CM into AIS codes has been used for many years. Recently, a program called ICDPIC trauma and developed in the USA has become available free of charge for registered STATA users. We compared the ICDPIC calculated Injury Severity Score (ISS) with the one from direct, prospective AIS coding by expert trauma registrars (dAIS). The administrative records of the 289 major trauma cases admitted to the hospital of Udine-Italy from 1 July 2004 to 30 June 2005 and enrolled in the Italian Trauma Registry were retrieved and ICDPIC-ISS was calculated. The agreement between ICDPIC-ISS and dAIS-ISS was assessed by Cohen's Kappa and Bland-Altman charts. We then plotted the differences between the 2 scores against the ratio between the number of traumatic ICD-9-CM codes and the number of dAIS codes for each patient (DIARATIO). We also compared the absolute differences in ISS among 3 groups identified by DIARATIO. The discriminative power for survival of both scores was finally calculated by ROC curves. The scores matched in 33/272 patients (12.1%, k 0.07) and, when categorized, in 80/272 (22.4%, k 0.09). The Bland-Altman average difference was 6.36 (limits: minus 22.0 to plus 34.7). ICDPIC-ISS of 75 was particularly unreliable. The differences increased (p < 0.01) as DIARATIO increased indicating incomplete administrative coding as a cause of the differences. The area under the curve of ICDPIC-ISS was lower (0.63 vs. 0.76, p = 0.02). Despite its great potential convenience, ICPIC-ISS agreed poorly with its conventionally calculated counterpart. Its discriminative power for survival was also significantly lower. Incomplete ICD-9-CM coding was a main cause of these findings. Because this

  17. Interfacial B-site atomic configuration in polar (111) and non-polar (001) SrIrO3/SrTiO3 heterostructures

    NASA Astrophysics Data System (ADS)

    Anderson, T. J.; Zhou, H.; Xie, L.; Podkaminer, J. P.; Patzner, J. J.; Ryu, S.; Pan, X. Q.; Eom, C. B.

    2017-09-01

    The precise control of interfacial atomic arrangement in ABO3 perovskite heterostructures is paramount, particularly in cases where the subsequent electronic properties of the material exhibit geometrical preferences along polar crystallographic directions that feature inevitably complex surface reconstructions. Here, we present the B-site interfacial structure in polar (111) and non-polar (001) SrIrO3/SrTiO3 interfaces. The heterostructures were examined using scanning transmission electron microscopy and synchrotron-based coherent Bragg rod analysis. Our results reveal the preference of B-site intermixing across the (111) interface due to the polarity-compensated SrTiO3 substrate surface prior to growth. By comparison, the intermixing at the non-polar (001) interface is negligible. This finding suggests that the intermixing may be necessary to mitigate epitaxy along heavily reconstructed and non-stoichiometric (111) perovskite surfaces. Furthermore, this preferential B-site configuration could allow the geometric design of the interfacial perovskite structure and chemistry to selectively engineer the correlated electronic states of the B-site d-orbital.

  18. Comparison of the performance of mental health, drug and alcohol comorbidities based on ICD-10-AM and medical records for predicting 12-month outcomes in trauma patients.

    PubMed

    Nguyen, Tu Q; Simpson, Pamela M; Braaf, Sandra C; Cameron, Peter A; Judson, Rodney; Gabbe, Belinda J

    2018-06-05

    Many outcome studies capture the presence of mental health, drug and alcohol comorbidities from administrative datasets and medical records. How these sources compare as predictors of patient outcomes has not been determined. The purpose of the present study was to compare mental health, drug and alcohol comorbidities based on ICD-10-AM coding and medical record documentation for predicting longer-term outcomes in injured patients. A random sample of patients (n = 500) captured by the Victorian State Trauma Registry was selected for the study. Retrospective medical record reviews were conducted to collect data about documented mental health, drug and alcohol comorbidities while ICD-10-AM codes were obtained from routinely collected hospital data. Outcomes at 12-months post-injury were the Glasgow Outcome Scale - Extended (GOS-E), European Quality of Life Five Dimensions (EQ-5D-3L), and return to work. Linear and logistic regression models, adjusted for age and gender, using medical record derived comorbidity and ICD-10-AM were compared using measures of calibration (Hosmer-Lemeshow statistic) and discrimination (C-statistic and R 2 ). There was no demonstrable difference in predictive performance between the medical record and ICD-10-AM models for predicting the GOS-E, EQ-5D-3L utility sore and EQ-5D-3L mobility, self-care, usual activities and pain/discomfort items. The area under the receiver operating characteristic (AUC) for models using medical record derived comorbidity (AUC 0.68, 95% CI: 0.63, 0.73) was higher than the model using ICD-10-AM data (AUC 0.62, 95% CI: 0.57, 0.67) for predicting the EQ-5D-3L anxiety/depression item. The discrimination of the model for predicting return to work was higher with inclusion of the medical record data (AUC 0.69, 95% CI: 0.63, 0.76) than the ICD-10-AM data (AUC 0.59, 95% CL: 0.52, 0.65). Mental health, drug and alcohol comorbidity information derived from medical record review was not clearly superior for

  19. Building a model for disease classification integration in oncology, an approach based on the national cancer institute thesaurus.

    PubMed

    Jouhet, Vianney; Mougin, Fleur; Bréchat, Bérénice; Thiessard, Frantz

    2017-02-07

    Identifying incident cancer cases within a population remains essential for scientific research in oncology. Data produced within electronic health records can be useful for this purpose. Due to the multiplicity of providers, heterogeneous terminologies such as ICD-10 and ICD-O-3 are used for oncology diagnosis recording purpose. To enable disease identification based on these diagnoses, there is a need for integrating disease classifications in oncology. Our aim was to build a model integrating concepts involved in two disease classifications, namely ICD-10 (diagnosis) and ICD-O-3 (topography and morphology), despite their structural heterogeneity. Based on the NCIt, a "derivative" model for linking diagnosis and topography-morphology combinations was defined and built. ICD-O-3 and ICD-10 codes were then used to instantiate classes of the "derivative" model. Links between terminologies obtained through the model were then compared to mappings provided by the Surveillance, Epidemiology, and End Results (SEER) program. The model integrated 42% of neoplasm ICD-10 codes (excluding metastasis), 98% of ICD-O-3 morphology codes (excluding metastasis) and 68% of ICD-O-3 topography codes. For every codes instantiating at least a class in the "derivative" model, comparison with SEER mappings reveals that all mappings were actually available in the model as a link between the corresponding codes. We have proposed a method to automatically build a model for integrating ICD-10 and ICD-O-3 based on the NCIt. The resulting "derivative" model is a machine understandable resource that enables an integrated view of these heterogeneous terminologies. The NCIt structure and the available relationships can help to bridge disease classifications taking into account their structural and granular heterogeneities. However, (i) inconsistencies exist within the NCIt leading to misclassifications in the "derivative" model, (ii) the "derivative" model only integrates a part of ICD-10 and ICD-O

  20. Leisure-time activities of patients with ICDs: findings of a survey with respect to sports activity, high altitude stays, and driving patterns.

    PubMed

    Kobza, Richard; Duru, Firat; Erne, Paul

    2008-07-01

    Physicians who are caring for patients with implantable cardioverter-defibrillators (ICDs) are regularly confronted with questions concerning daily activities. This study evaluates the habits of ICD patients with respect to sports activities, stays at high-altitude, and driving patterns. A survey was performed in 387 patients with ICDs who were followed at two hospitals in Switzerland. The special-designed questionnaire addressed lifestyle practices concerning sports activity, high-altitude visits, and driving motor vehicles. Fifty-nine percent of ICD patients participated in some kind of sports activity; an ICD shock was experienced in 14% of these patients. Fifty-six percent of the patients reported a stay at high altitudes at least 2,000 m above the sea level; 11% of them stayed regularly above 2,500 m; 4% of these patients experienced an ICD shock during high altitude stay. Seventy-nine percent of the patients drove a motor vehicle; 2% of them experienced an ICD shock during driving, but none of them reported loss of consciousness or a traffic accident. It is accepted that ICD patients disqualify for competitive sports. However, the patients may be encouraged to continue leisure-time physical activities at low-to-moderate intensity. Staying at high altitudes and driving motor vehicles are very rarely associated with ICD shocks. Therefore, these activities that are likely to contribute to a better quality of life should not be discouraged in most ICD recipients in the absence of other medical reasons.

  1. Comparison of ICD code-based diagnosis of obesity with measured obesity in children and the implications for health care cost estimates.

    PubMed

    Kuhle, Stefan; Kirk, Sara F L; Ohinmaa, Arto; Veugelers, Paul J

    2011-12-21

    Administrative health databases are a valuable research tool to assess health care utilization at the population level. However, their use in obesity research limited due to the lack of data on body weight. A potential workaround is to use the ICD code of obesity to identify obese individuals. The objective of the current study was to investigate the sensitivity and specificity of an ICD code-based diagnosis of obesity from administrative health data relative to the gold standard measured BMI. Linkage of a population-based survey with anthropometric measures in elementary school children in 2003 with longitudinal administrative health data (physician visits and hospital discharges 1992-2006) from the Canadian province of Nova Scotia. Measured obesity was defined based on the CDC cut-offs applied to the measured BMI. An ICD code-based diagnosis obesity was defined as one or more ICD-9 (278) or ICD-10 code (E66-E68) of obesity from a physician visit or a hospital stay. Sensitivity and specificity were calculated and health care cost estimates based on measured obesity and ICD-based obesity were compared. The sensitivity of an ICD code-based obesity diagnosis was 7.4% using ICD codes between 2002 and 2004. Those correctly identified had a higher BMI and had higher health care utilization and costs. An ICD diagnosis of obesity in Canadian administrative health data grossly underestimates the true prevalence of childhood obesity and overestimates the health care cost differential between obese and non-obese children.

  2. Tachycardia detection in ICDs by Boston Scientific : Algorithms, pearls, and pitfalls.

    PubMed

    Zanker, Norbert; Schuster, Diane; Gilkerson, James; Stein, Kenneth

    2016-09-01

    The aim of this study was to summarize how implantable cardioverter defibrillators (ICDs) by Boston Scientific sense, detect, discriminate rhythms, and classify episodes. Modern devices include multiple programming selections, diagnostic features, therapy options, memory functions, and device-related history features. Device operation includes logical steps from sensing, detection, discrimination, therapy delivery to history recording. The program is designed to facilitate the application of the device algorithms to the individual patient's clinical needs. Features and functions described in this article represent a selective excerpt by the authors from Boston Scientific publicly available product resources. Programming of ICDs may affect patient outcomes. Patient-adapted and optimized programming requires understanding of device operation and concepts.

  3. DSM-IV, DSM-5, and ICD-11: Identifying children with posttraumatic stress disorder after disasters.

    PubMed

    Danzi, BreAnne A; La Greca, Annette M

    2016-12-01

    Different criteria for diagnosing posttraumatic stress disorder (PTSD) have been recommended by the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the proposed 11th edition of the International Classification of Diseases (ICD-11). Although children are vulnerable to PTSD following disasters, little is known about whether these revised criteria are appropriate for preadolescents, as diagnostic revisions have been based primarily on adult research. This study investigated rates of PTSD using DSM-IV, DSM-5, and ICD-11 diagnostic criteria, and their associations with symptom severity, impairment, and PTSD risk factors. Children (7-11 years) exposed to Hurricanes Ike (n = 327) or Charley (n = 383) completed measures 8-9 months postdisaster. Using diagnostic algorithms for DSM-IV, DSM-5, and ICD-11, rates of 'probable' PTSD were calculated. Across samples, rates of PTSD were similar. However, there was low agreement across the diagnostic systems, with about a third overlap in identified cases. Children identified only by ICD-11 had higher 'core' symptom severity but lower impairment than children identified only by DSM-IV or DSM-5. ICD-11 was associated with more established risk factors for PTSD than was DSM-5. Findings revealed differences in PTSD diagnosis across major diagnostic systems for preadolescent children, with no clear advantage to any one system. Further research on developmentally sensitive PTSD criteria for preadolescent children is needed. © 2016 Association for Child and Adolescent Mental Health.

  4. Concordances and discrepancies between ICD-10 and DSM-IV criteria for anxiety disorders in childhood and adolescence

    PubMed Central

    2012-01-01

    Background Mental disorders are classified by two major nosological systems, the ICD-10 and the DSM-IV-TR, consisting of different diagnostic criteria. The present study investigated the diagnostic concordance between the two systems for anxiety disorders in childhood and adolescence, in particular for separation anxiety disorder (SAD), specific phobia, social phobia, and generalized anxiety disorder (GAD). Methods A structured clinical interview, the Kinder-DIPS, was administered to 210 children and 258 parents. The percentage of agreement, kappa, and Yule’s Y coefficients were calculated for all diagnoses. Specific criteria causing discrepancies between the two classification systems were identified. Results DSM-IV-TR consistently classified more children than ICD-10 with an anxiety disorder, with a higher concordance between DSM-IV-TR and the ICD-10 child section (F9) than with the adult section (F4) of the ICD-10. This result was found for all four investigated anxiety disorders. The results revealed low to high levels of concordance and poor to good agreement between the classification systems, depending on the anxiety disorder. Conclusions The two classification systems identify different children with an anxiety disorder. However, it remains an open question, whether the research results can be generalized to clinical practice since DSM-IV-TR is mainly used in research while ICD-10 is widely established in clinical practice in Europe. Therefore, the population investigated by the DSM (research population) is not identical with the population examined using the ICD (clinical population). PMID:23267678

  5. [Addiction in DSM V and ICD-11 state of the art].

    PubMed

    Lesch, O-M

    2009-09-01

    Diagnoses are made for identifying rather homogeneous groups of patients being thereby relevant for research and for therapy. Therefore diagnostic manuals, like the DSM-IV and the ICD-10 are subjected to changing knowledge derived from research on one hand and to changes of clinical necessities. The diagnosis of substance related disorders, published for DSM-IV in 1994 and for the ICD-10 in 1992, has proven of value for epidemiological research and economic validation. In spite of these advantages the concept has prove to be too broad and rather unspecific for research, specific therapeutic strategies and for defining an illness course. During the last 20 years research has yielded many criteria of interest, which never entered DSM IV or ICD-10, remaining therefore on the level of single items, which are nowadays additionally assigned to all patients (like e. g. early versus late onset) or on the level of typologies (like e. g. Lesch's typology) demanding different treatments. To give an example: acamprosate has lasting relapse preventing effects in Lesch types I and II, while naltrexone is effective in types III and IV. For rendering an expertise in Germany, the referring literature recommends to utilize Lesch's typology additionally to the ICD-10 diagnosis, especially when prognosis or therapeutic strategies are demanded. Since 1999 different expert groups strive for including new criteria into DSM IV and ICD-10. The revised manuals should include easily assignable items for severity of different arrays (time illness onset, co-morbidity, withdrawal symptoms, bridge symptoms and neurological sequela). Different therapy stages (e. g. withdrawal or relapse prevention) need a different weighting of individual symptoms (e. g. degree of intoxication, severity of withdrawal is needed for acute treatment, while an assignment of co-morbidity and personality factors is necessary for relapse prevention). This quantifier is rendered by Lesch's typology, which is available in

  6. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    PubMed

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-11-01

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  7. Minimally invasive percutaneous pericardial ICD placement in an infant piglet model: Head-to-head comparison with an open surgical thoracotomy approach.

    PubMed

    Clark, Bradley C; Davis, Tanya D; El-Sayed Ahmed, Magdy M; McCarter, Robert; Ishibashi, Nobuyuki; Jordan, Christopher P; Kane, Timothy D; Kim, Peter C W; Krieger, Axel; Nath, Dilip S; Opfermann, Justin D; Berul, Charles I

    2016-05-01

    Epicardial implantable cardioverter-defibrillator (ICD) placement in infants, children, and patients with complex cardiac anatomy requires an open surgical thoracotomy and is associated with increased pain, longer length of stay, and higher cost. The purpose of this study was to compare an open surgical epicardial placement approach with percutaneous pericardial placement of an ICD lead system in an infant piglet model. Animals underwent either epicardial placement by direct suture fixation through a left thoracotomy or minimally invasive pericardial placement with thoracoscopic visualization. Initial lead testing and defibrillation threshold testing (DFT) were performed. After the 2-week survival period, repeat lead testing and DFT were performed before euthanasia. Minimally invasive placement was performed in 8 piglets and open surgical placement in 7 piglets without procedural morbidity or mortality. The mean initial DFT value was 10.5 J (range 3-28 J) in the minimally invasive group and 10.0 J (range 5-35 J) in the open surgical group (P = .90). After the survival period, the mean DFT value was 12.0 J (range 3-20 J) in the minimally invasive group and 12.3 J (range 3-35 J) in the open surgical group (P = .95). All lead and shock impedances, R-wave amplitudes, and ventricular pacing thresholds remained stable throughout the survival period. Compared with open surgical epicardial ICD lead placement, minimally invasive pericardial placement demonstrates an equivalent ability to effectively defibrillate the heart and has demonstrated similar lead stability. With continued technical development and operator experience, the minimally invasive method may provide a viable alternative to epicardial ICD lead placement in infants, children, and adults at risk of sudden cardiac death. Copyright © 2016 Heart Rhythm Society. All rights reserved.

  8. Removing transgender identity from the classification of mental disorders: a Mexican field study for ICD-11.

    PubMed

    Robles, Rebeca; Fresán, Ana; Vega-Ramírez, Hamid; Cruz-Islas, Jeremy; Rodríguez-Pérez, Victor; Domínguez-Martínez, Tecelli; Reed, Geoffrey M

    2016-09-01

    for body transformation, most commonly hormones (182 [73%)], with the first such intervention at a mean age of 25·0 years (SD 9·1, range 10-54). 84 (46%) of those who had used hormones did so initially without medical supervision. During adolescence, distress related to gender identity was very common, but not universal (n=208 [83%]), and average level of distress was quite high among those who reported it (79·9 on a scale of 0 [none at all] to 100 [extreme], SD 20·7, range 20-100). Most participants (n=226 [90%] reported experiencing family, social, or work or scholastic dysfunction related to their gender identity, but this was typically moderate (on a scale of 0 [not at all disrupted] to 10 [extremely disrupted], family dysfunction mean 5·3 [SD 3·9, range 0-10]; social dysfunction mean 5·0 [SD 3·8, range 0-10]; work or scholastic dysfunction mean 4·8 [SD 3·6, range 0-10]). Multivariate logistic regression models indicated that distress and all types of dysfunction were strongly predicted by experiences of social rejection (odds ratios [ORs] 2·29-8·15) and violence (1·99-3·99). A current male gender identity also predicted distress (OR 3·90). Of the indicators of gender incongruence, only asking to be treated as a different gender was a significant predictor, and only of work or scholastic dysfunction (OR 1·82). This study provides additional support for classifying health-related categories related to transgender identity outside the classification of mental disorders in the ICD-11. The reconceptualisation and related reclassification of transgender-related health conditions in the ICD-11 could serve as a useful instrument in the discussion of public health policies aimed at increasing access to appropriate services and reducing the victimisation of transgender people. National Institute of Psychiatry Ramón de la Fuente Muñiz, Mexico. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Accuracy of lung cancer ICD-9-CM codes in Umbria, Napoli 3 Sud and Friuli Venezia Giulia administrative healthcare databases: a diagnostic accuracy study

    PubMed Central

    Montedori, Alessandro; Bidoli, Ettore; Serraino, Diego; Fusco, Mario; Giovannini, Gianni; Casucci, Paola; Franchini, David; Granata, Annalisa; Ciullo, Valerio; Vitale, Maria Francesca; Gobbato, Michele; Chiari, Rita; Cozzolino, Francesco; Orso, Massimiliano; Orlandi, Walter

    2018-01-01

    Objectives To assess the accuracy of International Classification of Diseases 9th Revision–Clinical Modification (ICD-9-CM) codes in identifying subjects with lung cancer. Design A cross-sectional diagnostic accuracy study comparing ICD-9-CM 162.x code (index test) in primary position with medical chart (reference standard). Case ascertainment was based on the presence of a primary nodular lesion in the lung and cytological or histological documentation of cancer from a primary or metastatic site. Setting Three operative units: administrative databases from Umbria Region (890 000 residents), ASL Napoli 3 Sud (NA) (1 170 000 residents) and Friuli Venezia Giulia (FVG) Region (1 227 000 residents). Participants Incident subjects with lung cancer (n=386) diagnosed in primary position between 2012 and 2014 and a population of non-cases (n=280). Outcome measures Sensitivity, specificity and positive predictive value (PPV) for 162.x code. Results 130 cases and 94 non-cases were randomly selected from each database and the corresponding medical charts were reviewed. Most of the diagnoses for lung cancer were performed in medical departments. True positive rates were high for all the three units. Sensitivity was 99% (95% CI 95% to 100%) for Umbria, 97% (95% CI 91% to 100%) for NA, and 99% (95% CI 95% to 100%) for FVG. The false positive rates were 24%, 37% and 23% for Umbria, NA and FVG, respectively. PPVs were 79% (73% to 83%)%) for Umbria, 58% (53% to 63%)%) for NA and 79% (73% to 84%)%) for FVG. Conclusions Case ascertainment for lung cancer based on imaging or endoscopy associated with histological examination yielded an excellent sensitivity in all the three administrative databases. PPV was moderate for Umbria and FVG but lower for NA. PMID:29773701

  10. Comparing the dimensional structure and diagnostic algorithms between DSM-5 and ICD-11 PTSD in children and adolescents.

    PubMed

    Sachser, Cedric; Berliner, Lucy; Holt, Tonje; Jensen, Tine; Jungbluth, Nathaniel; Risch, Elizabeth; Rosner, Rita; Goldbeck, Lutz

    2018-02-01

    In contrast to the DSM-5, which expanded the posttraumatic stress disorder (PTSD) symptom profile to 20 symptoms, a workgroup of the upcoming ICD-11 suggested a reduced symptom profile with six symptoms for PTSD. Therefore, the objective of the study was to investigate the dimensional structure of DSM-5 and ICD-11 PTSD in a clinical sample of trauma-exposed children and adolescents and to compare the diagnostic rates of PTSD between diagnostic systems. The study sample consisted of 475 self-reports and 424 caregiver-reports on the child and adolescent trauma screen (CATS), which were collected at pediatric mental health clinics in the US, Norway and Germany. The factor structure of the PTSD construct as defined in the DSM-5 and in alternative models of both DSM-5 and ICD-11 was investigated using confirmatory factor analyses (CFA). To evaluate differences in PTSD prevalence, McNemar's tests for correlated proportions were used. CFA results demonstrated excellent model fit for the proposed ICD-11 model of PTSD. For the DSM-5 models we found the best fit for the hybrid model. Diagnostic rates were significantly lower according to ICD-11 (self-report: 23.4%; caregiver-report: 16.5%) compared with the DSM-5 (self-report: 37.8%; caregiver-report: 31.8%). Agreement was low between diagnostic systems. Study findings provide support for an alternative latent dimensionality of DSM-5 PTSD in children and adolescents. The conceptualization of ICD-11 PTSD shows an excellent fit. Inconsistent PTSD constructs and significantly diverging diagnostic rates between DSM-5 and the ICD-11 will result in major challenges for researchers and clinicians in the field of psychotraumatology.

  11. The ICD-11 developmental field study of reliability of diagnoses of high-burden mental disorders: results among adult patients in mental health settings of 13 countries.

    PubMed

    Reed, Geoffrey M; Sharan, Pratap; Rebello, Tahilia J; Keeley, Jared W; Elena Medina-Mora, María; Gureje, Oye; Luis Ayuso-Mateos, José; Kanba, Shigenobu; Khoury, Brigitte; Kogan, Cary S; Krasnov, Valery N; Maj, Mario; de Jesus Mari, Jair; Stein, Dan J; Zhao, Min; Akiyama, Tsuyoshi; Andrews, Howard F; Asevedo, Elson; Cheour, Majda; Domínguez-Martínez, Tecelli; El-Khoury, Joseph; Fiorillo, Andrea; Grenier, Jean; Gupta, Nitin; Kola, Lola; Kulygina, Maya; Leal-Leturia, Itziar; Luciano, Mario; Lusu, Bulumko; Nicolas, J; Martínez-López, I; Matsumoto, Chihiro; Umukoro Onofa, Lucky; Paterniti, Sabrina; Purnima, Shivani; Robles, Rebeca; Sahu, Manoj K; Sibeko, Goodman; Zhong, Na; First, Michael B; Gaebel, Wolfgang; Lovell, Anne M; Maruta, Toshimasa; Roberts, Michael C; Pike, Kathleen M

    2018-06-01

    Reliable, clinically useful, and globally applicable diagnostic classification of mental disorders is an essential foundation for global mental health. The World Health Organization (WHO) is nearing completion of the 11th revision of the International Classification of Diseases and Related Health Problems (ICD-11). The present study assessed inter-diagnostician reliability of mental disorders accounting for the greatest proportion of global disease burden and the highest levels of service utilization - schizophrenia and other primary psychotic disorders, mood disorders, anxiety and fear-related disorders, and disorders specifically associated with stress - among adult patients presenting for treatment at 28 participating centers in 13 countries. A concurrent joint-rater design was used, focusing specifically on whether two clinicians, relying on the same clinical information, agreed on the diagnosis when separately applying the ICD-11 diagnostic guidelines. A total of 1,806 patients were assessed by 339 clinicians in the local language. Intraclass kappa coefficients for diagnoses weighted by site and study prevalence ranged from 0.45 (dysthymic disorder) to 0.88 (social anxiety disorder) and would be considered moderate to almost perfect for all diagnoses. Overall, the reliability of the ICD-11 diagnostic guidelines was superior to that previously reported for equivalent ICD-10 guidelines. These data provide support for the suitability of the ICD-11 diagnostic guidelines for implementation at a global level. The findings will inform further revision of the ICD-11 diagnostic guidelines prior to their publication and the development of programs to support professional training and implementation of the ICD-11 by WHO member states. © 2018 World Psychiatric Association.

  12. Adapting a Clinical Data Repository to ICD-10-CM through the use of a Terminology Repository

    PubMed Central

    Cimino, James J.; Remennick, Lyubov

    2014-01-01

    Clinical data repositories frequently contain patient diagnoses coded with the International Classification of Diseases, Ninth Revision (ICD-9-CM). These repositories now need to accommodate data coded with the Tenth Revision (ICD-10-CM). Database users wish to retrieve relevant data regardless of the system by which they are coded. We demonstrate how a terminology repository (the Research Entities Dictionary or RED) serves as an ontology relating terms of both ICD versions to each other to support seamless version-independent retrieval from the Biomedical Translational Research Information System (BTRIS) at the National Institutes of Health. We make use of the Center for Medicare and Medicaid Services’ General Equivalence Mappings (GEMs) to reduce the modeling effort required to determine whether ICD-10-CM terms should be added to the RED as new concepts or as synonyms of existing concepts. A divide-and-conquer approach is used to develop integration heuristics that offer a satisfactory interim solution and facilitate additional refinement of the integration as time and resources allow. PMID:25954344

  13. International variation in the definition of 'main condition' in ICD-coded health data.

    PubMed

    Quan, H; Moskal, L; Forster, A J; Brien, S; Walker, R; Romano, P S; Sundararajan, V; Burnand, B; Henriksson, G; Steinum, O; Droesler, S; Pincus, H A; Ghali, W A

    2014-10-01

    Hospital-based medical records are abstracted to create International Classification of Disease (ICD) coded discharge health data in many countries. The 'main condition' is not defined in a consistent manner internationally. Some countries employ a 'reason for admission' rule as the basis for the main condition, while other countries employ a 'resource use' rule. A few countries have recently transitioned from one of these approaches to the other. The definition of 'main condition' in such ICD data matters when it is used to define a disease cohort to assign diagnosis-related groups and to perform risk adjustment. We propose a method of harmonizing the international definition to enable researchers and international organizations using ICD-coded health data to aggregate or compare hospital care and outcomes across countries in a consistent manner. Inter-observer reliability of alternative harmonization approaches should be evaluated before finalizing the definition and adopting it worldwide. © The Author 2014. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  14. Gender, Racial, and Health Insurance Differences in the Trend of Implantable Cardioverter-Defibrillator (ICD) Utilization: A United States Experience Over the Last Decade.

    PubMed

    Patel, Nileshkumar J; Edla, Sushruth; Deshmukh, Abhishek; Nalluri, Nikhil; Patel, Nilay; Agnihotri, Kanishk; Patel, Achint; Savani, Chirag; Patel, Nish; Bhimani, Ronak; Thakkar, Badal; Arora, Shilpkumar; Asti, Deepak; Badheka, Apurva O; Parikh, Valay; Mitrani, Raul D; Noseworthy, Peter; Paydak, Hakan; Viles-Gonzalez, Juan; Friedman, Paul A; Kowalski, Marcin

    2016-02-01

    Prior studies have highlighted disparities in cardiac lifesaving procedure utilization, particularly among women and in minorities. Although there has been a significant increase in implantable cardioverter-defibrillator (ICD) insertion, socioeconomic disparities still exist in the trend of ICD utilization. With the use of the Nationwide Inpatient Sample from 2003 through 2011, we identified subjects with ICD insertion (procedure code 37.94) and cardiac resynchronization defibrillator (procedure code 00.50, 00.51) as codified by the International Classification of Diseases, Ninth Revision, Clinical Modification. Overall, 1 020 076 ICDs were implanted in the United States from 2003 to 2011. We observed an initial increase in ICD utilization by 51%, from 95 062 in 2003 to 143 262 in 2006, followed by a more recent decline. The majority of ICDs were implanted in men age ≥65 years. Implantation of ICDs was 2.5× more common in men than in women (402 per million vs 163 per million). Approximately 95% of the ICDs were implanted in insured patients, and 5% were used in the uninsured population. There has been a significant increase in ICD implantation in blacks, from 162 per million in 2003 to 291 per million in 2011. We found a significant difference in the volume of ICD implants between the insured and the uninsured patient populations. Racial disparities have narrowed significantly in comparison with those noted in earlier studies and are now more reflective of the population demographics at large. On the other hand, significant gender disparities continue to exist. © 2016 Wiley Periodicals, Inc.

  15. ICDE Librarians' Roundtable (Hong Kong, October 11-12, 1999).

    ERIC Educational Resources Information Center

    Wai-man, Wong; Schafer, Steve; Watson, Elizabeth F.; Tai-loon, Fong

    The International Council for Open and Distance Education (ICDE) Librarians' Roundtable is the first of its kind for librarians of international distance and open education institutions to exchange their views on how to cope with the development of their institutions in the use of new technology, and in the provision of library services to…

  16. Questions to Ask Your Doctor--Implantable Cardioverter Defibrillator (ICD)

    MedlinePlus

    ... affect my family member or me because of gender? Does age have any bearing on how the ICD works? Does one kind of therapy ... brief, easy to follow and easy to read. Many topics also available in Spanish . ... 4 Warning Signs of a Heart Attack 5 How to Eat Healthy 6 What are the Symptoms ...

  17. International variation in the definition of ‘main condition’ in ICD-coded health data

    PubMed Central

    Quan, H.; Moskal, L.; Forster, A.J.; Brien, S.; Walker, R.; Romano, P.S.; Sundararajan, V.; Burnand, B.; Henriksson, G.; Steinum, O.; Droesler, S.; Pincus, H.A.; Ghali, W.A.

    2014-01-01

    Hospital-based medical records are abstracted to create International Classification of Disease (ICD) coded discharge health data in many countries. The ‘main condition’ is not defined in a consistent manner internationally. Some countries employ a ‘reason for admission’ rule as the basis for the main condition, while other countries employ a ‘resource use’ rule. A few countries have recently transitioned from one of these approaches to the other. The definition of ‘main condition’ in such ICD data matters when it is used to define a disease cohort to assign diagnosis-related groups and to perform risk adjustment. We propose a method of harmonizing the international definition to enable researchers and international organizations using ICD-coded health data to aggregate or compare hospital care and outcomes across countries in a consistent manner. Inter-observer reliability of alternative harmonization approaches should be evaluated before finalizing the definition and adopting it worldwide. PMID:24990594

  18. Cross-cultural and comparative epidemiology of insomnia: the Diagnostic and statistical manual (DSM), International classification of diseases (ICD) and International classification of sleep disorders (ICSD).

    PubMed

    Chung, Ka-Fai; Yeung, Wing-Fai; Ho, Fiona Yan-Yee; Yung, Kam-Ping; Yu, Yee-Man; Kwok, Chi-Wa

    2015-04-01

    To compare the prevalence of insomnia according to symptoms, quantitative criteria, and Diagnostic and Statistical Manual of Mental Disorders, 4th and 5th Edition (DSM-IV and DSM-5), International Classification of Diseases, 10th Revision (ICD-10), and International Classification of Sleep Disorders, 2nd Edition (ICSD-2), and to compare the prevalence of insomnia disorder between Hong Kong and the United States by adopting a similar methodology used by the America Insomnia Survey (AIS). Population-based epidemiological survey respondents (n = 2011) completed the Brief Insomnia Questionnaire (BIQ), a validated scale generating DSM-IV, DSM-5, ICD-10, and ICSD-2 insomnia disorder. The weighted prevalence of difficulty falling asleep, difficulty staying asleep, waking up too early, and non-restorative sleep that occurred ≥3 days per week was 14.0%, 28.3%, 32.1%, and 39.9%, respectively. When quantitative criteria were included, the prevalence dropped the most from 39.9% to 8.4% for non-restorative sleep, and the least from 14.0% to 12.9% for difficulty falling asleep. The weighted prevalence of DSM-IV, ICD-10, ICSD-2, and any of the three insomnia disorders was 22.1%, 4.7%, 15.1%, and 22.1%, respectively; for DSM-5 insomnia disorder, it was 10.8%. Compared with 22.1%, 3.9%, and 14.7% for DSM-IV, ICD-10, and ICSD-2 in the AIS, cross-cultural difference in the prevalence of insomnia disorder is less than what is expected. The prevalence is reduced by half from DSM-IV to DSM-5. ICD-10 insomnia disorder has the lowest prevalence, perhaps because excessive concern and preoccupation, one of its diagnostic criteria, is not always present in people with insomnia. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Constructing a classification of hypersensitivity/allergic diseases for ICD-11 by crowdsourcing the allergist community.

    PubMed

    Tanno, L K; Calderon, M A; Goldberg, B J; Gayraud, J; Bircher, A J; Casale, T; Li, J; Sanchez-Borges, M; Rosenwasser, L J; Pawankar, R; Papadopoulos, N G; Demoly, P

    2015-06-01

    The global allergy community strongly believes that the 11th revision of the International Classification of Diseases (ICD-11) offers a unique opportunity to improve the classification and coding of hypersensitivity/allergic diseases via inclusion of a specific chapter dedicated to this disease area to facilitate epidemiological studies, as well as to evaluate the true size of the allergy epidemic. In this context, an international collaboration has decided to revise the classification of hypersensitivity/allergic diseases and to validate it for ICD-11 by crowdsourcing the allergist community. After careful comparison between ICD-10 and 11 beta phase linearization codes, we identified gaps and trade-offs allowing us to construct a classification proposal, which was sent to the European Academy of Allergy and Clinical Immunology (EAACI) sections, interest groups, executive committee as well as the World Allergy Organization (WAO), and American Academy of Allergy Asthma and Immunology (AAAAI) leaderships. The crowdsourcing process produced comments from 50 of 171 members contacted by e-mail. The classification proposal has also been discussed at face-to-face meetings with experts of EAACI sections and interest groups and presented in a number of business meetings during the 2014 EAACI annual congress in Copenhagen. As a result, a high-level complex structure of classification for hypersensitivity/allergic diseases has been constructed. The model proposed has been presented to the WHO groups in charge of the ICD revision. The international collaboration of allergy experts appreciates bilateral discussion and aims to get endorsement of their proposals for the final ICD-11. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Inclusion of Gaming Disorder in ICD has more advantages than disadvantages.

    PubMed

    Király, Orsolya; Demetrovics, Zsolt

    2017-09-01

    This paper is a response to a recent debate paper in which Aarseth et al. argue that the inclusion of a formal diagnosis and categories for problematic video gaming or Gaming Disorder (GD) in the World Health Organization's 11th Revision of the International Classification of Diseases (ICD-11) is premature and therefore the proposal should be removed. The present authors systematically address all the six main arguments presented by Aarseth et al. and argue that, even though some of the concerns presented in the debate paper are legitimate, the inclusion of GD in ICD-11 has more advantages than disadvantages. Furthermore, the present authors also argue that the two GD subtypes ("GD, predominantly online" and "GD, predominantly offline") are unnecessary and rather problematic; the main category for GD would be perfectly sufficient.

  1. Mn-Site Doped CaMnO 3: Creation of the CMR Effect

    NASA Astrophysics Data System (ADS)

    Raveau, B.; Zhao, Y. M.; Martin, C.; Hervieu, M.; Maignan, A.

    2000-01-01

    The doping of CaMnO3-δ at Mn sites with pentavalent and hexavalent d0 elements - Nb, Ta, W, Mo - modifies the resistivity behavior of this phase, extending the insulating domain and increasing significantly the resistivity at low temperature as the doping element content increases. The higher valency of the doping element introduces electrons; i.e., Mn3+ species are formed in the Mn4+ matrix. Double exchange phenomena then allow ferromagnetic interactions, by application of external magnetic fields which are similar to those observed for electron-doped manganites Ca1-xLnxMnO3 (x≤0.15), but with smaller magnetic moments. Consequently, this Mn site doping induces CMR properties with resistivity ratios considerably larger than those for CaMnO3-δ.

  2. The Design of the Understanding Outcomes with the S-ICD in Primary Prevention Patients with Low EF Study (UNTOUCHED).

    PubMed

    Gold, Michael R; Knops, Reinoud; Burke, Martin C; Lambiase, Pier D; Russo, Andrea M; Bongiorni, Maria Grazia; Deharo, Jean-Claude; Aasbo, Johan; El Chami, Mikhael F; Husby, Michael; Carter, Nathan; Boersma, Lucas

    2017-01-01

    The UNTOUCHED study will assess the safety and efficacy of the subcutaneous implantable cardioverter defibrillator (S-ICD) in the most common cohort of patients receiving ICDs. The primary goal is to evaluate the inappropriate shock (IAS)-free rate in primary prevention patients with a reduced ejection fraction (EF) and compare with a historical control of transvenous ICD patients with similar programming. The UNTOUCHED study is a global, multicenter, prospective, nonrandomized study of patients undergoing de novo S-ICD implantation for primary prevention of sudden cardiac death with a left ventricular EF ≤35%. The primary end point of this trial is freedom from IAS at 18 months. The lower 95% confidence bound of the observed incidence will be compared to a performance goal of 91.6%, which was derived from the IAS rate in MADIT-RIT. The secondary end points are all-cause shock-free rate at 18 months, and system- and procedure-related complication-free rate at 1 month and 6 months. Enrollment of a minimum of 1,100 subjects from up to 200 centers worldwide is planned based on power calculations of the primary and principal secondary end points. This trial will provide important data regarding the rates of inappropriate and appropriate shock therapy in real-world use of the S-ICD in the most common group of patients receiving ICDs. © 2016 Wiley Periodicals, Inc.

  3. The DRG shift: a new twist for ICD-10 preparation.

    PubMed

    Long, Peri L

    2012-06-01

    Analysis of your specific business is a key component of ICD-10 implementation. An understanding of your organization's current reimbursement trends will go a long way to assessing and preparing for the impact of ICD-10 in your environment. If you cannot be prepared for each detailed scenario, remember that much of the analysis and resolution requires familiar coding, DRG analysis, and claims processing best practices. Now, they simply have the new twist of researching new codes and some new concepts. The news of a delay in the implementation compliance date, along with the release of grouper Version 29, should encourage your educational and business analysis efforts. This is a great opportunity to maintain open communication with the Centers for Medicare & Medicaid Services, Department of Health and Human Services, and Centers for Disease Control. This is also a key time to report any unusual or discrepant findings in order to provide input to the final rule.

  4. Postperovskite phase equilibria in the MgSiO3-Al2O3 system.

    PubMed

    Tsuchiya, Jun; Tsuchiya, Taku

    2008-12-09

    We investigate high-P,T phase equilibria of the MgSiO(3)-Al(2)O(3) system by means of the density functional ab initio computation methods with multiconfiguration sampling. Being different from earlier studies based on the static substitution properties with no consideration of Rh(2)O(3)(II) phase, present calculations demonstrate that (i) dissolving Al(2)O(3) tends to decrease the postperovskite transition pressure of MgSiO(3) but the effect is not significant ( approximately -0.2 GPa/mol% Al(2)O(3)); (ii) Al(2)O(3) produces the narrow perovskite+postperovskite coexisting P,T area (approximately 1 GPa) for the pyrolitic concentration (x(Al2O3) approximately 6 mol%), which is sufficiently responsible to the deep-mantle D'' seismic discontinuity; (iii) the transition would be smeared (approximately 4 GPa) for the basaltic Al-rich composition (x(Al2O3) approximately 20 mol%), which is still seismically visible unless iron has significant effects; and last (iv) the perovskite structure spontaneously changes to the Rh(2)O(3)(II) with increasing the Al concentration involving small displacements of the Mg-site cations.

  5. Tunnel Propagation Following Defibrillation with ICD Shocks: Hidden Postshock Activations in the Left Ventricular Wall Underlie Isoelectric Window

    PubMed Central

    Constantino, Jason; Long, Yun; Ashihara, Takashi; Trayanova, Natalia A.

    2010-01-01

    Background Following near-defibrillation threshold (DFT) shocks from an ICD, the first postshock activation that leads to defibrillation failure arises focally after an isolelectric window (IW). The mechanisms underlying the IW remain incompletely understood. Objective The goal of this study was to provide mechanistic insight into the origins of postshock activations and IW following ICD shocks, and to link shock outcome to the preshock state of the ventricles. We hypothesized that the non-uniform ICD field results in the formation of an intramural excitable area (tunnel) only in the LV free wall, through which both pre-existing and new shock-induced wavefronts propagate during the IW. Methods Simulations were conducted using a realistic 3-D model of defibrillation in the rabbit ventricles. Biphasic ICD shocks of varying strengths were delivered to 27 different fibrillatory states. Results Following near-DFT shocks, regardless of preshock state, the main postshock excitable area was always located within LV free wall, creating an intramural tunnel. Either preexisting fibrillatory or shock-induced wavefronts propagated during the IW (duration of up to 74ms) in this tunnel and emerged as breakthroughs on LV epicardium. Preshock activity within the LV played a significant role in shock outcome: large number of preshock filaments resulted in an IW associated with tunnel propagation of preexisting rather than shock-induced wavefronts. Furthermore, shocks were more likely to succeed if LV excitable area was smaller. Conclusions The LV intramural excitable area is the primary reason for near-DFT failure. Any intervention that decreases the extent of this area will improve the likelihood of defibrillation success. PMID:20348028

  6. Impact of the introduction of a standardised ICD programming protocol: real-world data from a single centre.

    PubMed

    Sunderland, Nicholas; Kaura, Amit; Li, Anthony; Kamdar, Ravi; Petzer, Ed; Dhillon, Para; Murgatroyd, Francis; Scott, Paul A

    2016-09-01

    Randomised trials have shown that empiric ICD programming, using long detection times and high detection zones, reduces device therapy in ICD recipients. However, there is less data on its effectiveness in a "real-world" setting, especially secondary prevention patients. Our aim was to evaluate the introduction of a standardised programming protocol in a real-world setting of unselected ICD recipients. We analysed 270 consecutive ICD recipients implanted in a single centre-135 implanted prior to protocol implementation (physician-led group) and 135 after (standardised group). The protocol included long arrhythmia detection times (30/40 or equivalent) and high rate detection zones (primary prevention lower treatment zone 200 bpm). Programming in the physician-led group was at the discretion of the implanter. The primary endpoint was time-to-any therapy (ATP or shocks). Secondary endpoints were time-to-inappropriate therapy and time-to-appropriate therapy. The safety endpoints were syncopal episodes, hospital admissions and death. At 12 months follow-up, 47 patients had received any ICD therapy (physician-led group, n = 31 vs. standardised group, n = 16). There was a 47 % risk reduction in any device therapy (p = 0.04) and an 86 % risk reduction in inappropriate therapy (p = 0.009) in the standardised compared to the physician-led group. There was a non-significant 30 % risk reduction in appropriate therapy (p = 0.32). Results were consistent across primary and secondary prevention patients. There were no significant differences in the rates of syncope, hospitalisation, and death. In unselected patients in a real-world setting, introduction of a standardised programming protocol, using long detection times and high detection zones, significantly reduces the burden of ICD therapy without an increase in adverse outcomes.

  7. Depathologising gender diversity in childhood in the process of ICD revision and reform.

    PubMed

    Suess Schwend, Amets; Winter, Sam; Chiam, Zhan; Smiley, Adam; Cabral Grinspan, Mauro

    2018-01-24

    From 2007 on, the World Health Organisation (WHO) has been revising its diagnostic manual, the International Statistical Classification of Diseases and Related Health Problems (ICD), with approval of ICD-11 due in 2018. The ICD revision has prompted debates on diagnostic classifications related to gender diversity and gender development processes, and specifically on the 'Gender incongruence of childhood' (GIC) code. These debates have taken place at a time an emergent trans depathologisation movement is becoming increasingly international, and regional and international human rights bodies are recognising gender identity as a source of discrimination. With reference to the history of diagnostic classification of gender diversity in childhood, this paper conducts a literature review of academic, activist and institutional documents related to the current discussion on the merits of retaining or abandoning the GIC code. Within this broader discussion, the paper reviews in more detail recent publications arguing for the abandonment of this diagnostic code drawing upon clinical, bioethical and human rights perspectives. The review indicates that gender diverse children engaged in exploring their gender identity and expression do not benefit from diagnosis. Instead they benefit from support from their families, their schools and from society more broadly.

  8. Inclusion of Gaming Disorder in ICD has more advantages than disadvantages

    PubMed Central

    Király, Orsolya; Demetrovics, Zsolt

    2017-01-01

    This paper is a response to a recent debate paper in which Aarseth et al. argue that the inclusion of a formal diagnosis and categories for problematic video gaming or Gaming Disorder (GD) in the World Health Organization’s 11th Revision of the International Classification of Diseases (ICD-11) is premature and therefore the proposal should be removed. The present authors systematically address all the six main arguments presented by Aarseth et al. and argue that, even though some of the concerns presented in the debate paper are legitimate, the inclusion of GD in ICD-11 has more advantages than disadvantages. Furthermore, the present authors also argue that the two GD subtypes (“GD, predominantly online” and “GD, predominantly offline”) are unnecessary and rather problematic; the main category for GD would be perfectly sufficient. PMID:28816495

  9. ICD Social Codes: An Underutilized Resource for Tracking Social Needs.

    PubMed

    Torres, Jacqueline M; Lawlor, John; Colvin, Jeffrey D; Sills, Marion R; Bettenhausen, Jessica L; Davidson, Amber; Cutler, Gretchen J; Hall, Matt; Gottlieb, Laura M

    2017-09-01

    Social determinants of health (SDH) data collected in health care settings could have important applications for clinical decision-making, population health strategies, and the design of performance-based incentives and penalties. One source for cataloging SDH data is the International Statistical Classification of Diseases and Related Health Problems (ICD). To explore how SDH are captured with ICD Ninth revision SDH V codes in a national inpatient discharge database. Data come from the 2013 Healthcare Cost and Utilization Project (HCUP) National Inpatient Sample, a national stratified sample of discharges from 4363 hospitals from 44 US states. We estimate the rate of ICD-9 SDH V code utilization overall and by patient demographics and payer categories. We additionally estimate the rate of SDH V code utilization for: (a) the 5 most common reasons for hospitalization; and (b) the 5 conditions with the highest rates of SDH V code utilization. Fewer than 2% of overall discharges in the National Inpatient Sample were assigned an SDH V code. There were statistically significant differences in the rate of overall SDH V code utilization by age categories, race/ethnicity, sex, and payer (all P<0.001). Nevertheless, SDH V codes were assigned to <7% of discharges in any demographic or payer subgroup. SDH V code utilization was highest for major diagnostic categories related to mental health and alcohol/substance use-related discharges. SDH V codes are infrequently utilized in inpatient settings for discharges other than those related to mental health and alcohol/substance use. Utilization incentives will likely need to be developed to realize the potential benefits of cataloging SDH information.

  10. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator. Findings from the COPE-ICD randomised clinical trial.

    PubMed

    Berg, Selina Kikkenborg; Pedersen, Preben U; Zwisler, Ann-Dorthe; Winkel, Per; Gluud, Christian; Pedersen, Birthe D; Svendsen, Jesper H

    2015-02-01

    The aim of this randomised clinical trial was to assess a comprehensive cardiac rehabilitation intervention including exercise training and psycho-education vs 'treatment as usual' in patients treated with an implantable cardioverter defibrillator (ICD). In this study 196 patients with first time ICD implantation (mean age 57.2 (standard deviation (SD)=13.2); 79% men) were randomised (1:1) to comprehensive cardiac rehabilitation vs 'treatment as usual'. Altogether 144 participants completed the 12 month follow-up. The intervention consisted of twelve weeks of exercise training and one year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO₂), were used. Post-hoc analyses included SF-36 and ICD therapy history. Comprehensive cardiac rehabilitation significantly increased VO2 uptake after exercise training to 23.0 (95% confidence interval (CI) 20.9-22.7) vs 20.8 (95% CI 18.9-22.7) ml/min/kg in the control group (p=0.004 (multiplicity p=0.015)). Comprehensive cardiac rehabilitation significantly increased general health; at three months (mean 62.8 (95% CI 58.1-67.5) vs 64.4 (95% CI: 59.6-69.2)) points; at six months (mean 66.7 (95% CI 61.5-72.0) vs 61.9 (95% CI 56.1-67.7) points); and 12 months (mean 63.5 (95% CI 57.7-69.3) vs 62.1 (95% CI 56.2-68.0)) points (p <0.05). Explorative analyses showed a significant difference between groups in favour of the intervention group. No significant difference was seen in ICD therapy history. Comprehensive cardiac rehabilitation combining exercise training and a psycho-educational intervention improves VO₂-uptake and general health. Furthermore, mental health seems improved. No significant difference was found in the number of ICD shocks or anti-tachycardia pacing therapy. © The European Society of Cardiology 2014.

  11. Frequency of ICD-10 psychiatric diagnosis in children with intellectual disability in Lahore, Pakistan & Caregivers Perspective.

    PubMed

    Imran, Nazish; Azeem, Muhammad Waqar; Sattar, Ahsan; Bhatti, Mohammad Riaz

    2015-01-01

    Association between Intellectual disability (ID) and psychiatric disorders in children & adolescents is well established but there is a paucity of published studies from Pakistan on this topic. The main aim of the study was to assess the frequency of ICD-10 psychiatric diagnosis in the hospital outpatient sample of children with ID in Lahore, Pakistan as well as to find out which challenging behaviors, caregivers find difficult to manage in this setup. Socio-demographic information was collected, Wechsler Intelligence Scale for Children-Revised & ICD-10 diagnostic criteria was used to assess children (age range 6 - 16 years) with suspected ID along with identification of behaviors found to be difficult to manage by caregivers. 150 children were assessed with mean age of 10.7 years (males 70 %). Majority (72%) had mild ID while 18.7% and 9.3% had moderate and severe ID respectively. Thirty percent of children met the criteria for any psychiatric diagnosis, the most common being Oppositional Defiant Disorder (14%) and Hyperkinetic Disorders (10%). Verbal and physical aggression, school difficulties, socialization problems, inappropriate behaviors (e.g. disinhibition), sleep & feeding difficulties were the significant areas identified by the caregivers as a cause of major concern. Significantly high prevalence of ICD-10 psychiatric diagnosis in children with ID was found in Lahore, Pakistan. Support services for these children should be responsive not only to the needs of the child, but also to the needs of the family.

  12. Frequency of ICD-10 psychiatric diagnosis in children with intellectual disability in Lahore, Pakistan & Caregivers Perspective

    PubMed Central

    Imran, Nazish; Azeem, Muhammad Waqar; Sattar, Ahsan; Bhatti, Mohammad Riaz

    2015-01-01

    Objective: Association between Intellectual disability (ID) and psychiatric disorders in children & adolescents is well established but there is a paucity of published studies from Pakistan on this topic. The main aim of the study was to assess the frequency of ICD-10 psychiatric diagnosis in the hospital outpatient sample of children with ID in Lahore, Pakistan as well as to find out which challenging behaviors, caregivers find difficult to manage in this setup. Methods: Socio-demographic information was collected, Wechsler Intelligence Scale for Children-Revised & ICD-10 diagnostic criteria was used to assess children (age range 6 – 16 years) with suspected ID along with identification of behaviors found to be difficult to manage by caregivers. Results: 150 children were assessed with mean age of 10.7 years (males 70 %). Majority (72%) had mild ID while 18.7% and 9.3% had moderate and severe ID respectively. Thirty percent of children met the criteria for any psychiatric diagnosis, the most common being Oppositional Defiant Disorder (14%) and Hyperkinetic Disorders (10%). Verbal and physical aggression, school difficulties, socialization problems, inappropriate behaviors (e.g. disinhibition), sleep & feeding difficulties were the significant areas identified by the caregivers as a cause of major concern. Conclusions: Significantly high prevalence of ICD-10 psychiatric diagnosis in children with ID was found in Lahore, Pakistan. Support services for these children should be responsive not only to the needs of the child, but also to the needs of the family. PMID:26101476

  13. How does an implantable cardioverter defibrillator (ICD) affect the lives of patients and their families?

    PubMed

    Eckert, Marion; Jones, Tina

    2002-06-01

    This study aimed to identify the lived experience of patients with implantable cardioverter defibrillators (ICD) and their families. The methodology used was interpretative phenomenology. Unstructured interviews were conducted with three family members and three ICD recipients. Using a methodological approach outlined by van Manen, the participants transcribed texts were analysed looking for similar concepts and ideas that developed into themes that explicated the meaning of this phenomena. The themes that emerged were: dependence, which encompassed their perceptions about the life-saving device; the memory of their first defibrillation experience; lifestyle changes, which incorporated modification techniques; lack of control, which highlighted feelings such as fear, anxiety and powerlessness; mind game, which illustrated psychological challenges; and the issue of security, demonstrating how 'being there' and not 'being there' impacted on their everyday lives. The long-term outcomes of living with an ICD are important considerations for all health-care providers. This research highlights the everyday activities of recipients, the lifestyle changes they have made, the emotional significance of the device and the psychological coping strategies that the participants have adopted. The findings of this research will allow health-care professionals to be better prepared to provide education and support for ICD recipients and their families in regards to issues related to insertion of the device during the postinsertion recovery period and for long-term management after hospital discharge.

  14. Thermoelectric properties of p-type perovskite compounds LaCoO3 systems containing the A-site vacancy

    NASA Astrophysics Data System (ADS)

    Anzai, Mayuka; Kawakami, Hiroshi; Saito, Miwa; Yamamura, Hiroshi

    2011-05-01

    Thermoelectric properties of Sr-doped LaCoO3 system which includes both La1-xSrxCoO3 and La0.95-xSrxsquare0.05CoO3 containing the A-site vacancy were prepared by solid state reaction. The crystal phases of the samples were investigated by X-ray diffraction method. The electrical conductivity, Seebeck coefficient, and thermal conductivity were investigated, focusing the effect of A-site vacancy. Doping of Sr to LaCoO3 improved the electrical conductivity but decreased the seebeck coefficient and increased the thermal conductivity. A-site vacancy of La0.95-xSrxsquare0.05CoO3 system, in comparison with La1-xSrxCoO3 system, increased electrical conductivity, and decreased lattice thermal conductivity. As a result, it was found that the thermoelectric properties of La0.95-xSrxsquare0.05CoO3 containing the A-site vacancy showed the higher values than those of La1-xSrxCoO3. The introduction of A-site vacancy was effective on the improvement of thermoelectric property.

  15. Investigation of radiation shielding properties for MeO-PbCl2-TeO2 (MeO = Bi2O3, MoO3, Sb2O3, WO3, ZnO) glasses

    NASA Astrophysics Data System (ADS)

    Sayyed, M. I.; Çelikbilek Ersundu, M.; Ersundu, A. E.; Lakshminarayana, G.; Kostka, P.

    2018-03-01

    In this work, glasses in the MeO-PbCl2-TeO2 (MeO = Bi2O3, MoO3, Sb2O3, WO3, ZnO) system, which show a great potential for optoelectronic applications, were used to evaluate their resistance under high energy ionizing radiations. The basic shielding quantities for determining the penetration of radiation in glass, such as mass attenuation coefficient (μ/ρ), half value layer (HVL), mean free path (MFP) and exposure buildup factor (EBF) values were investigated within the energy range 0.015 MeV ‒ 15 MeV using XCOM program and variation of shielding parameters were compared with different glass systems and ordinary concrete. From the derived results, it was determined that MeO-PbCl2-TeO2 (MeO = Bi2O3, MoO3, Sb2O3, WO3, ZnO) glasses show great potentiality to be used under high energy radiations. Among the studied glass compositions, Bi2O3 and WO3 containing glasses were found to possess superior gamma-ray shielding effectiveness.

  16. DSM-5 and ICD-11 as competing models of PTSD in preadolescent children exposed to a natural disaster: assessing validity and co-occurring symptomatology.

    PubMed

    La Greca, Annette M; Danzi, BreAnne A; Chan, Sherilynn F

    2017-01-01

    Background : Major revisions have been made to the DSM and ICD models of post-traumatic stress disorder (PTSD). However, it is not known whether these models fit children's post-trauma responses, even though children are a vulnerable population following disasters. Objective : Using data from Hurricane Ike, we examined how well trauma-exposed children's symptoms fit the DSM-IV, DSM-5 and ICD-11 models, and whether the models varied by gender. We also evaluated whether elevated symptoms of depression and anxiety characterized children meeting PTSD criteria based on DSM-5 and ICD-11. Method : Eight-months post-disaster, children ( N  = 327, 7-11 years) affected by Hurricane Ike completed measures of PTSD, anxiety and depression. Algorithms approximated a PTSD diagnosis based on DSM-5 and ICD-11 models. Results : Using confirmatory factor analysis, ICD-11 had the best-fitting model, followed by DSM-IV and DSM-5. The ICD-11 model also demonstrated strong measurement invariance across gender. Analyses revealed poor overlap between DSM-5 and ICD-11, although children meeting either set of criteria reported severe PTSD symptoms. Further, children who met PTSD criteria for DSM-5, but not for ICD-11, reported significantly higher levels of depression and general anxiety than children not meeting DSM-5 criteria. Conclusions : Findings support the parsimonious ICD-11 model of PTSD for trauma-exposed children, although adequate fit also was obtained for DSM-5. Use of only one model of PTSD, be it DSM-5 or ICD-11, will likely miss children with significant post-traumatic stress. DSM-5 may identify children with high levels of comorbid symptomatology, which may require additional clinical intervention.

  17. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Antiferromagnetic interaction between A'-site Mn spins in A-site-ordered perovskite YMn3Al4O12.

    PubMed

    Tohyama, Takenori; Saito, Takashi; Mizumaki, Masaichiro; Agui, Akane; Shimakawa, Yuichi

    2010-03-01

    The A-site-ordered perovskite YMn(3)Al(4)O(12) was prepared by high-pressure synthesis. Structural analysis with synchrotron powder X-ray diffraction data and the Mn L-edges X-ray absorption spectrum revealed that the compound has a chemical composition Y(3+)Mn(3+)(3)Al(3+)(4)O(2-)(12) with magnetic Mn(3+) at the A' site and non-magnetic Al(3+) at the B site. An antiferromagnetic interaction between the A'-site Mn(3+) spins is induced by the nearest neighboring Mn-Mn direct exchange interaction and causes an antiferromagnetic transition at 34.3 K.

  19. Luminescence and energy transfer of Tb3+-doped BaO-Gd2O3-Al2O3-B2O3-SiO2 glasses.

    PubMed

    Zuo, Chenggang; Huang, Jinze; Liu, Shaoyou; Xiao, Anguo; Shen, Youming; Zhang, Xiangyang; Zhou, Zhihua; Zhu, Ligang

    2017-12-05

    Transparent Tb 3+ -doped BaO-Gd 2 O 3 -Al 2 O 3 -B 2 O 3 -SiO 2 glasses with the greater than 4g/cm 3 were prepared by high temperature melting method and its luminescent properties have been investigated by measured UV-vis transmission, excitation, emission and luminescence decay spectra. The transmission spectrum shows there are three weak absorption bands locate at about 312, 378 and 484nm in the glasses and it has good transmittance in the visible spectrum region. Intense green emission can be observed under UV excitation. The effective energy transfer from Gd 3+ ion to Tb 3+ ion could occur and sensitize the luminescence of Tb 3+ ion. The green emission intensity of Tb 3+ ion could change with the increasing SiO 2 /B 2 O 3 ratio in the borosilicate glass matrix. With the increasing concentration of Tb 3+ ion, 5 D 4 → 7 F J transitions could be enhanced through the cross relaxation between the two nearby Tb 3+ ions. Luminescence decay time of 2.12ms from 546nm emission is obtained. The results indicate that Tb 3+ -doped BaO-Gd 2 O 3 -Al 2 O 3 -B 2 O 3 -SiO 2 glasses would be potential scintillating material for applications in X-ray imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. First-principles analysis of ferroelectric transition in MnSnO3 and MnTiO3 perovskites

    NASA Astrophysics Data System (ADS)

    Kang, Sung Gu

    2018-06-01

    The ferroelectric instabilities of an artificially adopted Pnma structure in low tolerance perovskites have been explored (Kang et al., 2017) [4], where an unstable A-site environment was reported to be the major driving source for the low tolerance perovskites to exhibit ferroelectric instability. This study examined the ferroelectric transition of two magnetic perovskite materials, MnSnO3 and MnTiO3, in Pnma phase. Phase transitions to the Pnma phase at elevated pressures were observed. MnSnO3, which has a lower (larger) tolerance factor (B-site cation radius), showed a higher ferroelectric mode amplitude than MnTiO3. The distribution of the bond length of Mn-O and the mean quadratic elongation (QE) of octahedra (SnO6 or TiO6) were investigated for structural analysis. However, MnTiO3 showed a larger spontaneous polarization than MnSnO3 due to high Born effective charges of titanium. This study is useful because it provides a valuable pathway to the design of promising multiferroic materials.

  1. DSM-5 and ICD-11 as competing models of PTSD in preadolescent children exposed to a natural disaster: assessing validity and co-occurring symptomatology

    PubMed Central

    La Greca, Annette M.; Danzi, BreAnne A.; Chan, Sherilynn F.

    2017-01-01

    ABSTRACT Background: Major revisions have been made to the DSM and ICD models of post-traumatic stress disorder (PTSD). However, it is not known whether these models fit children’s post-trauma responses, even though children are a vulnerable population following disasters. Objective: Using data from Hurricane Ike, we examined how well trauma-exposed children’s symptoms fit the DSM-IV, DSM-5 and ICD-11 models, and whether the models varied by gender. We also evaluated whether elevated symptoms of depression and anxiety characterized children meeting PTSD criteria based on DSM-5 and ICD-11. Method: Eight-months post-disaster, children (N = 327, 7–11 years) affected by Hurricane Ike completed measures of PTSD, anxiety and depression. Algorithms approximated a PTSD diagnosis based on DSM-5 and ICD-11 models. Results: Using confirmatory factor analysis, ICD-11 had the best-fitting model, followed by DSM-IV and DSM-5. The ICD-11 model also demonstrated strong measurement invariance across gender. Analyses revealed poor overlap between DSM-5 and ICD-11, although children meeting either set of criteria reported severe PTSD symptoms. Further, children who met PTSD criteria for DSM-5, but not for ICD-11, reported significantly higher levels of depression and general anxiety than children not meeting DSM-5 criteria. Conclusions: Findings support the parsimonious ICD-11 model of PTSD for trauma-exposed children, although adequate fit also was obtained for DSM-5. Use of only one model of PTSD, be it DSM-5 or ICD-11, will likely miss children with significant post-traumatic stress. DSM-5 may identify children with high levels of comorbid symptomatology, which may require additional clinical intervention. PMID:28451076

  2. Postperovskite phase equilibria in the MgSiO3–Al2O3 system

    PubMed Central

    Tsuchiya, Jun; Tsuchiya, Taku

    2008-01-01

    We investigate high-P,T phase equilibria of the MgSiO3–Al2O3 system by means of the density functional ab initio computation methods with multiconfiguration sampling. Being different from earlier studies based on the static substitution properties with no consideration of Rh2O3(II) phase, present calculations demonstrate that (i) dissolving Al2O3 tends to decrease the postperovskite transition pressure of MgSiO3 but the effect is not significant (≈-0.2 GPa/mol% Al2O3); (ii) Al2O3 produces the narrow perovskite+postperovskite coexisting P,T area (≈1 GPa) for the pyrolitic concentration (xAl2O3 ≈6 mol%), which is sufficiently responsible to the deep-mantle D″ seismic discontinuity; (iii) the transition would be smeared (≈4 GPa) for the basaltic Al-rich composition (xAl2O3 ≈20 mol%), which is still seismically visible unless iron has significant effects; and last (iv) the perovskite structure spontaneously changes to the Rh2O3(II) with increasing the Al concentration involving small displacements of the Mg-site cations. PMID:19036928

  3. Investigating the local structure of B-site cations in (1-x)BaTiO3-xBiScO3 and (1-x)PbTiO3-xBiScO3 using X-ray absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Blanchard, Peter E. R.; Grosvenor, Andrew P.

    2018-05-01

    The structural properties of (1-x)BaTiO3-xBiScO3 and (1-x)PbTiO3-xBiScO3 were investigated using powder X-ray diffraction and X-ray absorption spectroscopy. Diffraction measurements confirmed that substituting small amounts of BiScO3 into BaTiO3 initially stabilizes a cubic phase at x = 0.2 before impurity phases begin to form at x = 0.5. BiScO3 substitution also resulted in noticeable changes in the local coordination environment of Ti4+. X-ray absorption near-edge spectroscopy (XANES) analysis showed that replacing Ti4+ with Sc3+ results in an increase in the off-centre displacement of Ti4+ cations. Surprisingly, BiScO3 substitution has no effect on the displacement of the Ti4+ cation in the (1-x)PbTiO3-xBiScO3 solid solution.

  4. From Novice to Expert: Problem Solving in ICD-10-PCS Procedural Coding

    PubMed Central

    Rousse, Justin Thomas

    2013-01-01

    The benefits of converting to ICD-10-CM/PCS have been well documented in recent years. One of the greatest challenges in the conversion, however, is how to train the workforce in the code sets. The International Classification of Diseases, Tenth Revision, Procedure Coding System (ICD-10-PCS) has been described as a language requiring higher-level reasoning skills because of the system's increased granularity. Training and problem-solving strategies required for correct procedural coding are unclear. The objective of this article is to propose that the acquisition of rule-based logic will need to be augmented with self-evaluative and critical thinking. Awareness of how this process works is helpful for established coders as well as for a new generation of coders who will master the complexities of the system. PMID:23861674

  5. [Patients with ICD-10 disorders F3 and F4 in psychiatric and psychosomatic in-patient units - who is treated where? : Allocation features from the PfAD study].

    PubMed

    Bichescu-Burian, D; Cerisier, C; Czekaj, A; Grempler, J; Hund, S; Jaeger, S; Schmid, P; Weithmann, G; Steinert, T

    2017-01-01

    In Germany, in-patient treatment of patients with depressive, neurotic, anxiety, and somatoform disorders (ICD-10 F3, F4) is carried out in different settings in psychiatry and psychosomatics. Which patient characteristics determine referral to one or the other specialty is a crucial question in mental health policy and is a matter of ongoing controversy. However, comparative data on patient populations are widely lacking. In the study of Treatment Pathways of Patients with Anxiety and Depression (PfAD study), a total of 320 patients with ICD-10 F3/F4 clinical diagnoses were consecutively recruited from four treatment settings (psychiatric depression ward, psychiatric crisis intervention ward, psychiatric day hospitals, or psychosomatic hospital units; 80 participants per setting) and investigated. In all treatment settings, patients with considerable severity of illness and chronicity were treated. Female gender, higher education, and higher income predicted referral to psychosomatic units; male gender, transfer from another hospital or emergency hospitalization, co-morbidity with a personality disorder, higher general psychiatric co-morbidity, and danger to self at admission predicted referral to psychiatric unit. Patients in psychosomatic units had neither more psychosomatic disorders nor more somatic problems. There is considerable overlap between the clientele of psychiatric and psychosomatic units. Referral and allocation appears to be determined by aspects of severity and social status.

  6. The proportion of uncoded diagnoses in computerized health insurance claims in Japan in May 2010 according to ICD-10 disease categories.

    PubMed

    Tanihara, Shinichi

    2014-01-01

    Uncoded diagnoses in computerized health insurance claims are excluded from statistical summaries of health-related risks and other factors. The effects of these uncoded diagnoses, coded according to ICD-10 disease categories, have not been investigated to date in Japan. I obtained all computerized health insurance claims (outpatient medical care, inpatient medical care, and diagnosis procedure-combination per-diem payment system [DPC/PDPS] claims) submitted to the National Health Insurance Organization of Kumamoto Prefecture in May 2010. These were classified according to the disease categories of the International Statistical Classification of Diseases and Related Health Problems, 10th Revision (ICD-10). I used accompanying text documentation related to the uncoded diagnoses to classify these diagnoses. Using these classifications, I calculated the proportion of uncoded diagnoses by ICD-10 category. The number of analyzed diagnoses was 3,804,246, with uncoded diagnoses accounting for 9.6% of the total. The proportion of uncoded diagnoses in claims for outpatient medical care, inpatient medical care, and DPC/PDPS were 9.3%, 10.9%, and 14.2%, respectively. Among the diagnoses, Congenital malformations, deformations, and chromosomal abnormalities had the highest proportion of uncoded diagnoses (19.3%), and Diseases of the respiratory system had the lowest proportion of uncoded diagnoses (4.7%). The proportion of uncoded diagnoses differed by the type of health insurance claim and disease category. These findings indicate that Japanese health statistics computed using computerized health insurance claims might be biased by the exclusion of uncoded diagnoses.

  7. Gender Incongruence of Adolescence and Adulthood: Acceptability and Clinical Utility of the World Health Organization’s Proposed ICD-11 Criteria

    PubMed Central

    Beek, Titia F.; Cohen-Kettenis, Peggy T.; Bouman, Walter P.; de Vries, Annelou L. C.; Steensma, Thomas D.; Witcomb, Gemma L.; Arcelus, Jon; Richards, Christina; Elaut, Els; Kreukels, Baudewijntje P. C.

    2016-01-01

    The World Health Organization (WHO) is currently updating the tenth version of their diagnostic tool, the International Classification of Diseases (ICD, WHO, 1992). Changes have been proposed for the diagnosis of Transsexualism (ICD-10) with regard to terminology, placement and content. The aim of this study was to gather the opinions of transgender individuals (and their relatives/partners) and clinicians in the Netherlands, Flanders (Belgium) and the United Kingdom regarding the proposed changes and the clinical applicability and utility of the ICD-11 criteria of ‘Gender Incongruence of Adolescence and Adulthood’ (GIAA). A total of 628 participants were included in the study: 284 from the Netherlands (45.2%), 8 from Flanders (Belgium) (1.3%), and 336 (53.5%) from the UK. Most participants were transgender people (or their partners/relatives) (n = 522), 89 participants were healthcare providers (HCPs) and 17 were both healthcare providers and (partners/relatives of) transgender people. Participants completed an online survey developed for this study. Most participants were in favor of the proposed diagnostic term of ‘Gender Incongruence’ and thought that this was an improvement on the ICD-10 diagnostic term of ‘Transsexualism’. Placement in a separate chapter dealing with Sexual- and Gender-related Health or as a Z-code was preferred by many and only a small number of participants stated that this diagnosis should be excluded from the ICD-11. In the UK, most transgender participants thought there should be a diagnosis related to being trans. However, if it were to be removed from the chapter on “psychiatric disorders”, many transgender respondents indicated that they would prefer it to be removed from the ICD in its entirety. There were no large differences between the responses of the transgender participants (or their partners and relatives) and HCPs. HCPs were generally positive about the GIAA diagnosis; most thought the diagnosis was clearly

  8. Pressure-induced ferroelectric to paraelectric transition in LiTaO 3 and (Li,Mg)TaO 3

    DOE PAGES

    Yamanaka, Takamitsu; Nakamoto, Yuki; Takei, Fumihiko; ...

    2016-02-16

    X-ray powder diffraction and Raman scattering of LiTaO 3 (LT) and (Li,Mg)TaO 3 (LMT) have been measured under pressure up to 46 GPa. Above 30 GPa, the ferroelectric rhombohedral phase (R3c, Z – 6) of LiTaO 3 transforms to a paraelectric orthorhombic phase (Pnma with Z – 4) with a large hysteresis. Rietveld profile fitting analysis shows that the Li-O bond is compressed and approaches that of Ta-O with pressure. The cation distribution analysis of the orthorhombic perovskite structure shows that Li and Ta are located in the octahedral 8-fold coordination sites. Difference Fourier |F obs(hkl)| - |F cal(hkl)| mapsmore » of LiTaO 3 and (Li,Mg)TaO 3 indicate polarization in the c axis direction and a more distinct electron density distribution around the Ta position for (Li,Mg)TaO 3 compared to LiTaO 3. The observed effective charges indicate that for (Li,Mg)TaO 3 without vacancies Ta 5+ becomes less ionized as a function of Mg substitution. Considering both site occupancy and effective charge analysis, Ta 5+ is reduced to Ta 4.13+. Mg 2+ and O 2- change to Mg 1.643+ and O 1.732 -, respectively. The space- and time-averaged structures of the dynamical vibration of atoms can be elucidated from the electron density analysis by difference Fourier and temperature factors T(hkl) in the structure refinement. The refinement of the temperature factor is consistent with the cation distribution assuming full stoichiometry. The residual electron density induced from the excess electron in (Li,Mg)TaO 3 indicates more electrons around the Ta site, as confirmed by the effective charge analysis. Raman spectra of LiTaO 3 and (Li,Mg)TaO 3 show notable changes over the measured pressure range. Raman peaks centered at 250 cm –1 and 350 cm –1 at ambient pressure merge above 8 GPa, which we associate with the diminishing of difference in distances between Li-O and Ta-O bonds with pressure in both materials. Finally, Raman spectra show significant changes at 28 GPa and 33 GPa for

  9. New resonances from the coherence of Auger and intercoulombic (ICD) processes in the photoionization of endohedral fullerenes

    NASA Astrophysics Data System (ADS)

    Chakraborty, Himadri; Wise, Jacob; de, Ruma; Javani, Mohammad; Manson, Steve; Madjet, Mohamed

    2014-05-01

    Considering the photoionization of Ar@C60 , we predict resonant femtosecond decays of both Ar and C60 vacancies through the continua of atom-fullerene hybrid final states. The resulting resonances emerge from the interference between simultaneous autoionizing and intercoulombic decay (ICD) processes. For Ar 3s --> np excitations, these resonances are far stronger than the Ar-to-C60 resonant ICDs, while for C60 excitations they are strikingly larger than the corresponding Auger features. The results indicate the power of hybridization to enhance decay rates, and modify lifetimes and line profiles. These decays are also likely to exist generally in the ionization of molecules, nano-dimers and -polymers, and fullerene onions that support hybridized electrons as well. A jellium based time-dependent local density approximation (TDLDA), with the Leeuwen and Baerends exchange-correlation functional to produce accurate asymptotic behavior, is employed to calculate the dynamical response of the system to the photon field.

  10. The solubility and site preference of Fe3+ in Li7−3xFexLa3Zr2O12 garnets

    PubMed Central

    Rettenwander, D.; Geiger, C.A.; Tribus, M.; Tropper, P.; Wagner, R.; Tippelt, G.; Lottermoser, W.; Amthauer, G.

    2015-01-01

    A series of Fe3+-bearing Li7La3Zr2O12 (LLZO) garnets was synthesized using solid-state synthesis methods. The synthetic products were characterized compositionally using electron microprobe analysis and inductively coupled plasma optical emission spectroscopy (ICP-OES) and structurally using X-ray powder diffraction and 57Fe Mössbauer spectroscopy. A maximum of about 0.25 Fe3+ pfu could be incorporated in Li7−3xFexLa3Zr2O12 garnet solid solutions. At Fe3+ concentrations lower than about 0.16 pfu, both tetragonal and cubic garnets were obtained in the synthesis experiments. X-ray powder diffraction analysis showed only a garnet phase for syntheses with starting materials having intended Fe3+ contents lower than 0.52 Fe3+ pfu. Back-scattered electron images made with an electron microprobe also showed no phase other than garnet for these compositions. The lattice parameter, a0, for all solid-solution garnets is similar with a value of a0≈12.98 Å regardless of the amount of Fe3+. 57Fe Mössbauer spectroscopic measurements indicate the presence of poorly- or nano-crystalline FeLaO3 in syntheses with Fe3+ contents greater than 0.16 Fe3+ pfu. The composition of different phase pure Li7−3xFexLa3Zr2O12 garnets, as determined by electron microprobe (Fe, La, Zr) and ICP-OES (Li) measurements, give Li6.89Fe0.03La3.05Zr2.01O12, Li6.66Fe0.06La3.06Zr2.01O12, Li6.54Fe0.12La3.01Zr1.98O12, and Li6.19Fe0.19La3.02Zr2.04O12. The 57Fe Mössbauer spectrum of cubic Li6.54Fe0.12La3.01Zr1.98O12 garnet indicates that most Fe3+ occurs at the special crystallographic 24d position, which is the standard tetrahedrally coordinated site in garnet. Fe3+ in smaller amounts occurs at a general 96h site, which is only present for certain Li-oxide garnets, and in Li6.54Fe0.12La3.01Zr1.98O12 this Fe3+ has a distorted 4-fold coordination. PMID:26435549

  11. Examining the impact of introducing ICD-MM on observed trends in maternal mortality rates in the UK 2003-13.

    PubMed

    Knight, Marian; Nair, Manisha; Brocklehurst, Peter; Kenyon, Sara; Neilson, James; Shakespeare, Judy; Tuffnell, Derek; Kurinczuk, Jennifer J

    2016-07-20

    The causes of maternal death are now classified internationally according to ICD-MM. One significant change with the introduction of ICD-MM in 2012 was the reclassification of maternal suicide from the indirect group to the direct group. This has led to concerns about the impact of this reclassification on calculated mortality rates. The aim of this analysis was to examine the trends in maternal deaths in the UK over the past 10 years, and to investigate the impact of reclassification using ICD-MM on the observed rates. Data about all maternal deaths between 2003-13 in the UK were included in this analysis. Data about maternal deaths occurring prior to 2009 were obtained from previously published reports. The deaths of women from 2009-13 during or after pregnancy were identified through the MBRRACE-UK Confidential Enquiry into Maternal Deaths. The underlying causes of maternal death were reclassified from a disease-based system to ICD-MM. Maternal mortality rates with 95 % confidence intervals were calculated using national data on the number of maternities as the denominator. Rate ratios with 95 % CI were calculated to compare the change in rates of maternal death as per ICD-MM relative to the old classification system. There was a decrease in the maternal death rate between 2003-05 and 2011-13 (rate ratio (RR) 0.65; 95 % CI 0.54-0.77 comparing 2003-5 with 2011-13; p = 0.005 for trend over time). The direct maternal death rate calculated using the old classification decreased with a RR of 0.47 (95 % CI 0.34-0.63) when comparing 2011-13 with 2003-05; p = 0.005 for trend over time. Reclassification using ICD-MM made little material difference to the observed trend in direct maternal death rates, RR = 0.51 (95 % CI 0.39-0.68) when comparing 2003-5 with 2011-13; p = 0.005 for trend over time. The impact of reclassifying maternal deaths according to ICD-MM in the UK was minimal. However, such reclassification raises awareness of maternal suicides

  12. Proposed declassification of disease categories related to sexual orientation in the International Statistical Classification of Diseases and Related Health Problems (ICD-11).

    PubMed

    Cochran, Susan D; Drescher, Jack; Kismödi, Eszter; Giami, Alain; García-Moreno, Claudia; Atalla, Elham; Marais, Adele; Vieira, Elisabeth Meloni; Reed, Geoffrey M

    2014-09-01

    The World Health Organization is developing the 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11), planned for publication in 2017. The Working Group on the Classification of Sexual Disorders and Sexual Health was charged with reviewing and making recommendations on disease categories related to sexuality in the chapter on mental and behavioural disorders in the 10th revision (ICD-10), published in 1990. This chapter includes categories for diagnoses based primarily on sexual orientation even though ICD-10 states that sexual orientation alone is not a disorder. This article reviews the scientific evidence and clinical rationale for continuing to include these categories in the ICD. A review of the evidence published since 1990 found little scientific interest in these categories. In addition, the Working Group found no evidence that they are clinically useful: they neither contribute to health service delivery or treatment selection nor provide essential information for public health surveillance. Moreover, use of these categories may create unnecessary harm by delaying accurate diagnosis and treatment. The Working Group recommends that these categories be deleted entirely from ICD-11. Health concerns related to sexual orientation can be better addressed using other ICD categories.

  13. Proposed declassification of disease categories related to sexual orientation in the International Statistical Classification of Diseases and Related Health Problems (ICD-11)

    PubMed Central

    Drescher, Jack; Kismödi, Eszter; Giami, Alain; García-Moreno, Claudia; Atalla, Elham; Marais, Adele; Vieira, Elisabeth Meloni; Reed, Geoffrey M

    2014-01-01

    Abstract The World Health Organization is developing the 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11), planned for publication in 2017. The Working Group on the Classification of Sexual Disorders and Sexual Health was charged with reviewing and making recommendations on disease categories related to sexuality in the chapter on mental and behavioural disorders in the 10th revision (ICD-10), published in 1990. This chapter includes categories for diagnoses based primarily on sexual orientation even though ICD-10 states that sexual orientation alone is not a disorder. This article reviews the scientific evidence and clinical rationale for continuing to include these categories in the ICD. A review of the evidence published since 1990 found little scientific interest in these categories. In addition, the Working Group found no evidence that they are clinically useful: they neither contribute to health service delivery or treatment selection nor provide essential information for public health surveillance. Moreover, use of these categories may create unnecessary harm by delaying accurate diagnosis and treatment. The Working Group recommends that these categories be deleted entirely from ICD-11. Health concerns related to sexual orientation can be better addressed using other ICD categories. PMID:25378758

  14. The ν 3 and 2ν 3 bands of 32S 16O 3, 32S 18O 3, 34S 16O 3, and 34S 18O 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharpe, Steven W.; Blake, Thomas A.; Sams, Robert L.

    2003-12-01

    The fifth of a series of publications on the high resolution rotation-vibration spectra of sulfur trioxide reports the results of a systematic study of the v3(é) and 2v3(A1'+E') infrared bands of the four symmetric top isotopomers 32S 16O 3, 34S 16O 3, 32S 18O 3, and 34S 18O 3. An internal coupling between the l = 0 and l = +2 levels of the 2v3 (A1'+E') states was observed. This small perturbation results in a level crossing between K-l = 9 and 12, in consequence of which the band origins of the A1', l=0 “ghost” states could be determined tomore » a high degree of accuracy. Ground and upper state rotational as well as vibrational anharmonicity constants are reported. The constants for the center-of-mass substituted species 32S 16O 3 and 34S 16O 3 vary only slightly, as do the constants for the 32S 18O 3, 34S 18O 3 pair. The S-O bond lengths for the vibrational ground states of the species 32S 16O 3, 34S 16O 3, 32S 18O 3 and 34S 18O 3, are, respectively, 141.981992(6), 141.979412(20), 150.605240(73), and 150.602348(73) pm, where the uncertainties, given in parentheses, are two standard deviations and refer to the last digits of the associated quantity.« less

  15. Orbital configuration in CaTiO 3 films on NdGaO 3

    DOE PAGES

    Cao, Yanwei; Park, Se Young; Liu, Xiaoran; ...

    2016-10-13

    Despite its use as a constituent layer for realization of a polar metal and interfacial conductivity, the microscopic study of electronic structure of CaTiO 3 is still very limited. Here, we epitaxially stabilized CaTiO 3 films on NdGaO 3 (110) substrates in a layer-by-layer way by pulsed laser deposition. The structural and electronic properties of the films were characterized by reflection-high-energy-electron-diffraction, X-ray diffraction, and element-specific resonant X-ray absorption spectroscopy. To reveal the orbital polarization and the crystal field splitting of the titanium 3d state, X-ray linear dichroism was carried out on CaTiO 3 films, demonstrating the orbital configuration of dmore » xz/d yz < d xy < d 3z2-r2 < d x2-y2. To further explore the origin of this configuration, we performed the first-principles density function theory calculations, which linked the orbital occupation to the on-site energy of Ti 3d orbitals. Finally, these findings can be important for understanding and designing exotic quantum states in heterostructures based on CaTiO 3.« less

  16. Chiari malformation Type I surgery in pediatric patients. Part 1: validation of an ICD-9-CM code search algorithm.

    PubMed

    Ladner, Travis R; Greenberg, Jacob K; Guerrero, Nicole; Olsen, Margaret A; Shannon, Chevis N; Yarbrough, Chester K; Piccirillo, Jay F; Anderson, Richard C E; Feldstein, Neil A; Wellons, John C; Smyth, Matthew D; Park, Tae Sung; Limbrick, David D

    2016-05-01

    OBJECTIVE Administrative billing data may facilitate large-scale assessments of treatment outcomes for pediatric Chiari malformation Type I (CM-I). Validated International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) code algorithms for identifying CM-I surgery are critical prerequisites for such studies but are currently only available for adults. The objective of this study was to validate two ICD-9-CM code algorithms using hospital billing data to identify pediatric patients undergoing CM-I decompression surgery. METHODS The authors retrospectively analyzed the validity of two ICD-9-CM code algorithms for identifying pediatric CM-I decompression surgery performed at 3 academic medical centers between 2001 and 2013. Algorithm 1 included any discharge diagnosis code of 348.4 (CM-I), as well as a procedure code of 01.24 (cranial decompression) or 03.09 (spinal decompression or laminectomy). Algorithm 2 restricted this group to the subset of patients with a primary discharge diagnosis of 348.4. The positive predictive value (PPV) and sensitivity of each algorithm were calculated. RESULTS Among 625 first-time admissions identified by Algorithm 1, the overall PPV for CM-I decompression was 92%. Among the 581 admissions identified by Algorithm 2, the PPV was 97%. The PPV for Algorithm 1 was lower in one center (84%) compared with the other centers (93%-94%), whereas the PPV of Algorithm 2 remained high (96%-98%) across all subgroups. The sensitivity of Algorithms 1 (91%) and 2 (89%) was very good and remained so across subgroups (82%-97%). CONCLUSIONS An ICD-9-CM algorithm requiring a primary diagnosis of CM-I has excellent PPV and very good sensitivity for identifying CM-I decompression surgery in pediatric patients. These results establish a basis for utilizing administrative billing data to assess pediatric CM-I treatment outcomes.

  17. A new ferroelectric solid solution system of LaCrO 3-BiCrO 3

    NASA Astrophysics Data System (ADS)

    Chen, J. I. L.; Kumar, M. Mahesh; Ye, Z.-G.

    2004-04-01

    A new perovskite solid solution system of (1- x)LaCrO 3- xBiCrO 3 has been prepared by conventional solid-state reaction and sintering processes at 1200°C in a sealed Pt tube or a Bi 2O 3-rich environment. A clean orthorhombic phase of LaCrO 3-type structure is established at room temperature for compositions with 0⩽ x⩽0.35. The relative density, lattice parameters, sintering mechanism, microstructure and ferroelectricity of the compounds are investigated. The substitution of Bi 2O 3 for La 2O 3 is found to decrease the unit cell volume and increase the grain size of the ceramics. The relative density of the ceramics sintered at 1200°C is significantly improved from 40% for LaCrO 3 up to about 90% for La 0.65Bi 0.35CrO 3 through a liquid phase sintering mechanism. The ferroelectricity is revealed in La 1- xBi xCrO 3 with 0.1⩽ x⩽0.35 by dielectric hysteresis loops displayed at 77 K. The remnant polarization is found to increase with increasing Bi 3+ content. The origin of the ferroelectricity is attributed to the structural distortion induced by the stereochemically active Bi 3+ ion on the A site.

  18. Gender incongruence: a comparative study using ICD-10 and DSM-5 diagnostic criteria.

    PubMed

    Soll, Bianca M; Robles-García, Rebeca; Brandelli-Costa, Angelo; Mori, Daniel; Mueller, Andressa; Vaitses-Fontanari, Anna M; Cardoso-da-Silva, Dhiordan; Schwarz, Karine; Abel-Schneider, Maiko; Saadeh, Alexandre; Lobato, Maria-Inês-Rodrigues

    2018-01-01

    To compare the presence of criteria listed in the DSM-5 and ICD-10 diagnostic manuals in a Brazilian sample of transgender persons seeking health services specifically for physical transition. This multicenter cross-sectional study included a sample of 103 subjects who sought services for gender identity disorder in two main reference centers in Brazil. The method involved a structured interview encompassing the diagnostic criteria in the two manuals. The results revealed that despite theoretical disagreement about the criteria, the manuals overlap regarding diagnosis confirmation; the DSM-5 was more inclusive (97.1%) than the ICD-10 (93.2%) in this population. Although there is no consensus on diagnostic criteria on transgenderism in the diversity of social and cultural contexts, more comprehensive diagnostic criteria are evolving due to society's increasing inclusivity.

  19. Space Segment (SS) and the Navigation User Segment (US) Interface Control Document (ICD)

    DOT National Transportation Integrated Search

    1993-10-10

    This Interface Control Document (ICD) defines the requirements related to the interface between the Space Segment (SS) of the Global Positioning System (GPS) and the Navigation Users Segment of the GPS. 2880k, 154p.

  20. A comparison of DSM-5 and ICD-11 PTSD prevalence, comorbidity and disability: an analysis of the Ukrainian Internally Displaced Person's Mental Health Survey.

    PubMed

    Shevlin, M; Hyland, P; Vallières, F; Bisson, J; Makhashvili, N; Javakhishvili, J; Shpiker, M; Roberts, B

    2018-02-01

    Recently, the American Psychiatric Association (DSM-5) and the World Health Organization (ICD-11) have both revised their formulation of post-traumatic stress disorder (PTSD). The primary aim of this study was to compare DSM-5 and ICD-11 PTSD prevalence and comorbidity rates, as well as the level of disability associated with each diagnosis. This study was based on a representative sample of adult Ukrainian internally displaced persons (IDPs: N = 2203). Post-traumatic stress disorder prevalence was assessed using the PTSD Checklist for DSM-5 and the International Trauma Questionnaire (ICD-11). Anxiety and depression were measured using the Generalized Anxiety Disorder Scale and the Patient Health Questionnaire-Depression. Disability was measured using the WHO Disability Assessment Schedule 2.0. The prevalence of DSM-5 PTSD (27.4%) was significantly higher than ICD-11 PTSD (21.0%), and PTSD rates for females were significantly higher using both criteria. ICD-11 PTSD was associated with significantly higher levels of disability and comorbidity. The ICD-11 diagnosis of PTSD appears to be particularly well suited to identifying those with clinically relevant levels of disability. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. EPR spectroscopic investigations in 15BaO-25Li2O-(60-x) B2O3-xFe2O3 glass system

    NASA Astrophysics Data System (ADS)

    Bhogi, Ashok; Kumar, R. Vijaya; Kistaiah, P.

    2018-05-01

    Glasses with composition 15BaO-25Li2O-(60-x) B2O3 -xFe2O3 (x = 0, 0.2, 0.4, 0.6, 0.8 and 1 mol %) were prepared by the conventional melt quenching technique. These glasses were characterized using X-ray diffraction (XRD). Electron paramagnetic resonance (EPR) investigations have been carried out as a function of iron ion concentration. The observed EPR spectra of Fe3+ ion exhibits resonance signals at g= 2.0, 4.3 and 8.0. The resonance signal at g= 4.3 is due to isolated Fe3+ ions in site with rhombic symmetry where as the g= 2.0 resonance signal is attributed to the Fe3+ ions coupled by exchange interaction in a distorted octahedral environment and the signal at g= 8.0 arises from axially distorted sites. The number of spins participating in resonance (N) and its paramagnetic susceptibilities (χ) have also been evaluated. The peak-to-peak line width ΔB for the resonance lines at g ≈ 4.3 and at g ≈ 2.0 is increasing as function of the iron ion content. The line intensity of the resonance centered at g ≈ 4.3 and at g ≈ 2.0 increases up to 0.8 mol% of Fe2O3 and for 1 mol% of Fe2O3 its value is found to decrease. The analysis of these results indicated that the conversion some of Fe3+ cations to Fe2+ ions beyond 0.8 mol%.

  2. Use of the Spine Adverse Events Severity System (SAVES) in patients with traumatic spinal cord injury. A comparison with institutional ICD-10 coding for the identification of acute care adverse events.

    PubMed

    Street, J T; Thorogood, N P; Cheung, A; Noonan, V K; Chen, J; Fisher, C G; Dvorak, M F

    2013-06-01

    Observational cohort comparison. To compare the previously validated Spine Adverse Events Severity system (SAVES) with International Classification of Diseases, Tenth Revision codes (ICD-10) codes for identifying adverse events (AEs) in patients with traumatic spinal cord injury (TSCI). Quaternary Care Spine Program. Patients discharged between 2006 and 2010 were identified from our prospective registry. Two consecutive cohorts were created based on the system used to record acute care AEs; one used ICD-10 coding by hospital coders and the other used SAVES data prospectively collected by a multidisciplinary clinical team. The ICD-10 codes were appropriately mapped to the SAVES. There were 212 patients in the ICD-10 cohort and 173 patients in the SAVES cohort. Analyses were adjusted to account for the different sample sizes, and the two cohorts were comparable based on age, gender and motor score. The SAVES system identified twice as many AEs per person as ICD-10 coding. Fifteen unique AEs were more reliably identified using SAVES, including neuropathic pain (32 × more; P<0.001), urinary tract infections (1.4 × ; P<0.05), pressure sores (2.9 × ; P<0.001) and intra-operative AEs (2.3 × ; P<0.05). Eight of these 15 AEs more frequently identified by SAVES significantly impacted length of stay (P<0.05). Risk factors such as patient age and severity of paralysis were more reliably correlated to AEs collected through SAVES than ICD-10. Implementation of the SAVES system for patients with TSCI captured more individuals experiencing AEs and more AEs per person compared with ICD-10 codes. This study demonstrates the utility of prospectively collecting AE data using validated tools.

  3. Validity of International Classification of Diseases (ICD) coding for dengue infections in hospital discharge records in Malaysia.

    PubMed

    Woon, Yuan-Liang; Lee, Keng-Yee; Mohd Anuar, Siti Fatimah Zahra; Goh, Pik-Pin; Lim, Teck-Onn

    2018-04-20

    Hospitalization due to dengue illness is an important measure of dengue morbidity. However, limited studies are based on administrative database because the validity of the diagnosis codes is unknown. We validated the International Classification of Diseases, 10th revision (ICD) diagnosis coding for dengue infections in the Malaysian Ministry of Health's (MOH) hospital discharge database. This validation study involves retrospective review of available hospital discharge records and hand-search medical records for years 2010 and 2013. We randomly selected 3219 hospital discharge records coded with dengue and non-dengue infections as their discharge diagnoses from the national hospital discharge database. We then randomly sampled 216 and 144 records for patients with and without codes for dengue respectively, in keeping with their relative frequency in the MOH database, for chart review. The ICD codes for dengue were validated against lab-based diagnostic standard (NS1 or IgM). The ICD-10-CM codes for dengue had a sensitivity of 94%, modest specificity of 83%, positive predictive value of 87% and negative predictive value 92%. These results were stable between 2010 and 2013. However, its specificity decreased substantially when patients manifested with bleeding or low platelet count. The diagnostic performance of the ICD codes for dengue in the MOH's hospital discharge database is adequate for use in health services research on dengue.

  4. Magneto-transport in LaTi1-xMnxO3/SrTiO3 oxide heterostructures

    NASA Astrophysics Data System (ADS)

    Kumar, Pramod; Dogra, Anjana; Budhani, R. C.

    2014-04-01

    We report the growth of ultrathin film of Mn doped LaTiO3 on TiO2 terminated SrTiO3 (001) substrate by pulsed laser deposition (PLD) and their electrical transport characteristics including magnetoresistance (MR). Though the replacement of Mn in LaTiO3 at the Ti site in dilute limit does not affect the metallic behaviour of films but variation in resistance is observed. Normalised resistance behaviour is explained on the basis of variation in charge carriers and increased interaction between Mn atoms in the system under investigation.

  5. Thickness dependent thermoelectric properties of SrTiO3/SrLaTiO3 and SrZrO3/SrLaTiO3 heterostructures

    NASA Astrophysics Data System (ADS)

    Ishii, Masatoshi; Baniecki, John; Schafranek, Robert; Kerman, Kian; Kurihara, Kazuaki

    2013-03-01

    Thermoelectric power generators will be required for future sensor network systems. SrTiO3 (STO) is one candidate thermoelectric material due to its non-toxicity and comparable power factor to Bismuth telluride. The energy conversion efficiency of SrTiO3-based thermoelectric energy conversion elements has been reported to be enhanced by quantum size effects, such as the two dimensional (2D) electron gas in SrTiO3/SrTi0.8Nb0.2O3/SrTiO3. Nevertheless, a complete understanding of the mechanisms for the reported increase in efficiency are missing owing to a lack of understanding of the thickness dependence of the transport properties. In the talk, we will present a study of the thickness dependence of the transport properties of SrTiO3/SrLaTiO3 and SrZrO3/SrLaTiO3 heterostructures. The SrZrO3/SrLaTiO3 interface has a large conduction band off-set of 1.9 eV which can be utilized to confine electrons in a 2D quantum well. Characterization of the thermopower, conductivity, and Hall effect will be presented as a function of the SrLaTiO3 thickness down to a few unit cells and the implications of the thickness dependence of the transport properties on carrier confinement and increasing the efficiency STO-based 2DEG quantum well structures will be discussed.

  6. Prevalence of resistance to antibiotics according to International Classification of Diseases (ICD-10) in Boo Ali Sina Hospital of Sari, 2011-2012.

    PubMed

    Afshar, Parvaneh; Saravi, Benyamin Mohseni; Nehmati, Ebrahim; Farahabbadi, Ebrahim Bagherian; Yazdanian, Azadeh; Siamian, Hasan; Vahedi, Mohammad

    2013-01-01

    One of the issues in health care delivery system is resistance to antibiotics. Many researches were done to show the causes and antibiotics which was resistance. In most researches the methods of classifying and reporting this resistance were made by researcher, so in this research we examined the International Classification of Diseases 10 the edition (ICD-10). This is a descriptive cross section study; data was collected from laboratory of Boo Ali Sina hospital, during 2011-2012. The check list was designed according the aim of study. Variables were age, bacterial agent, specimen, and antibiotics. The bacteria and resistance were classified with ICD-10. The data were analyzed with SPSS (16) soft ware and the descriptive statistics. Results showed that of the 10198 request for culture and antibiogram, there were 1020(10%) resistance. The specimen were 648 (63.5%) urine, blood 127(12.5%), other secretion 125 (12/3%), sputum 102 (10%), lumbar puncture 8 (0/8%), stool 6 (6/0%) and bone marrow 4 (0.4%). The E coli was the most 413 (40.5%) resistance cause to antibiotics which was coded with B96.2 and the most resistance was to multiple antibiotics 885(86.8%) with the U88 code. The results showed that by using the ICD-10 codes, the study of multiple causes and resistance is possible. The routine usage of coding of the ICD-10 would result to an up to date bank of resistance to antibiotics in every hospitals and useful for physicians, other health care, and health administrations.

  7. Enhancement in magnetocaloric properties of ErCrO3 via A-site Gd substitution

    NASA Astrophysics Data System (ADS)

    Shi, Jianhang; Yin, Shiqi; Seehra, Mohindar S.; Jain, Menka

    2018-05-01

    Rare earth chromites (RCrO3) continue to be of considerable interest due to their intriguing physical properties such as spin-reorientation, multiferroicity, and magnetocaloric effect. In this paper, we compare the structural, magnetic, and magnetocaloric properties of bulk ErCrO3 with those of bulk Er0.33Gd0.67CrO3, the latter obtained by Gd substitution at the A-site (Er-site) and report substantial enhancement in the magnetocaloric response by Gd substitution. The samples prepared by the citrate route were structurally characterized at room temperature using x-ray diffraction (XRD), Raman spectroscopy, and scanning electron microscopy. The XRD measurements refined by Rietveld analysis indicate that both samples crystallized in the orthorhombically distorted perovskite structure with Pbnm space group. Magnetic measurements on both samples were carried out between 5 K and 300 K in magnetic fields up to 7 T and show that TNC r (where Cr3+ orders) for Er0.33Gd0.67CrO3 is enhanced to 155 K vs. 133 K for ErCrO3 with analogous changes in the other magnetic parameters. Isothermal magnetization M vs. H data at different temperatures were used to determine changes in the magnetic entropy ( -ΔS ) and relative cooling power (RCP) for the two samples showing considerable improvement with Gd substitution in bulk ErCrO3. The maximum value of -ΔS for Er0.33Gd0.67CrO3 is 27.6 J kg-1 K-1 at 5 K and 7 T with a RCP of 531.1 J kg-1, in comparison to maximum -ΔS = 10.7 J kg-1 K-1 at 15 K with an RCP of 416.4 J kg-1 for ErCrO3 at 7 T.

  8. The ICD diagnoses of fetishism and sadomasochism.

    PubMed

    Reiersøl, Odd; Skeid, Svein

    2006-01-01

    In this article we discuss psychiatric diagnoses of sexual deviation as they appear in the International Classification of Diseases (ICD-10), the internationally accepted classification and diagnostic system of the World Health Organization (WHO). Namely, we discuss the background of three diagnostic categories: Fetishism (F65.0), Fetishistic Transvestism (F65.1), and Sadomasochism (F65.5). Pertinent background issues regarding the above categories are followed by a critique of the usefulness of diagnosing these phenomena today. Specifically, we argue that Fetishism, Fetishistic Transvestism, and Sadomasochism, also labeled Paraphilia or perversion, should not be considered illnesses. Finally, we present the efforts of an initiative known as ReviseF65, which was established in 1997, to abolish these diagnoses.

  9. Deep neural models for ICD-10 coding of death certificates and autopsy reports in free-text.

    PubMed

    Duarte, Francisco; Martins, Bruno; Pinto, Cátia Sousa; Silva, Mário J

    2018-04-01

    We address the assignment of ICD-10 codes for causes of death by analyzing free-text descriptions in death certificates, together with the associated autopsy reports and clinical bulletins, from the Portuguese Ministry of Health. We leverage a deep neural network that combines word embeddings, recurrent units, and neural attention, for the generation of intermediate representations of the textual contents. The neural network also explores the hierarchical nature of the input data, by building representations from the sequences of words within individual fields, which are then combined according to the sequences of fields that compose the inputs. Moreover, we explore innovative mechanisms for initializing the weights of the final nodes of the network, leveraging co-occurrences between classes together with the hierarchical structure of ICD-10. Experimental results attest to the contribution of the different neural network components. Our best model achieves accuracy scores over 89%, 81%, and 76%, respectively for ICD-10 chapters, blocks, and full-codes. Through examples, we also show that our method can produce interpretable results, useful for public health surveillance. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Disability, employment and work performance among people with ICD-10 anxiety disorders.

    PubMed

    Waghorn, Geoff; Chant, David; White, Paul; Whiteford, Harvey

    2005-01-01

    To ascertain at a population level, patterns of disability, labour force participation, employment and work performance among people with ICD-10 anxiety disorders in comparison to people without disability or long-term health conditions. A secondary analysis was conducted of a probability sample of 42 664 individuals collected in an Australian Bureau of Statistics (ABS) national survey in 1998. Trained lay interviewers using ICD-10 computer-assisted interviews identified household residents with anxiety disorders. Anxiety disorders were associated with: reduced labour force participation, degraded employment trajectories and impaired work performance compared to people without disabilities or long-term health conditions. People with anxiety disorders may need more effective treatments and assistance with completing education and training, joining and rejoining the workforce, developing career pathways, remaining in the workforce and sustaining work performance. A whole-of-government approach appears needed to reduce the burden of disease and increase community labour resources. Implications for clinicians, vocational professionals and policy makers are discussed.

  11. Evaluating Open-Source Full-Text Search Engines for Matching ICD-10 Codes.

    PubMed

    Jurcău, Daniel-Alexandru; Stoicu-Tivadar, Vasile

    2016-01-01

    This research presents the results of evaluating multiple free, open-source engines on matching ICD-10 diagnostic codes via full-text searches. The study investigates what it takes to get an accurate match when searching for a specific diagnostic code. For each code the evaluation starts by extracting the words that make up its text and continues with building full-text search queries from the combinations of these words. The queries are then run against all the ICD-10 codes until a match indicates the code in question as a match with the highest relative score. This method identifies the minimum number of words that must be provided in order for the search engines choose the desired entry. The engines analyzed include a popular Java-based full-text search engine, a lightweight engine written in JavaScript which can even execute on the user's browser, and two popular open-source relational database management systems.

  12. Gender trouble: The World Health Organization, the International Statistical Classification of Diseases and Related Health Problems (ICD)-11 and the trans kids.

    PubMed

    Winter, Sam

    2017-10-01

    The World Health Organization (WHO) is revising its diagnostic manual, the International Statistical Classification of Diseases and Related Health Problems (ICD). At the time of writing, and based on recommendations from its ICD Working Group on Sexual Disorders and Sexual Health, WHO is proposing a new ICD chapter titled Conditions Related to Sexual Health, and that the gender incongruence diagnoses (replacements for the gender identity disorder diagnoses used in ICD-10) should be placed in that chapter. WHO is proposing that there should be a Gender incongruence of childhood (GIC) diagnosis for children below the age of puberty. This last proposal has come under fire. Trans community groups, as well as many healthcare professionals and others working for transgender health and wellbeing, have criticised the proposal on the grounds that the pathologisation of gender diversity at such a young age is inappropriate, unnecessary, harmful and inconsistent with WHO's approach in regard to other aspects of development in childhood and youth. Counter proposals have been offered that do not pathologise gender diversity and instead make use of Z codes to frame and document any contacts that young gender diverse children may have with health services. The author draws on his involvement in the ICD revision process, both as a member of the aforementioned WHO Working Group and as one of its critics, to put the case against the GIC proposal, and to recommend an alternative approach for ICD in addressing the needs of gender diverse children.

  13. Synthesis and characterization of Eu{sup 3+}-doped CaZrO{sub 3}-based perovskite-type phosphors. Part I: Determination of the Eu{sup 3+} occupied site using the ALCHEMI technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakaida, Satoshi; Shimokawa, Yohei; Asaka, Toru

    2015-07-15

    Highlights: • Eu{sup 3+}-doped CaZrO{sub 3}-based compounds were synthesized by the solid state reaction. • PL emission intensity at 614 nm was changed by the second dopant cations. • The site substituted by Eu{sup 3+} cations was investigated by using XRD and ALCHEMI technique. • The dominant Eu{sup 3+} substitution site was found as the B site (Zr{sup 4+}) in the CaZrO{sub {sup 3}}. • The dominant Eu{sup 3+} substitution site could be strongly influenced by the co-dopants. - Abstract: Eu{sup 3+}-doped CaZrO{sub 3}, SrZrO{sub 3}, and Mg{sup 2+}- or Sr{sup 2+}-co-doped CaZrO{sub 3} were synthesized by conventional solid statemore » reaction and their photoluminescence (PL) properties were characterized. The Eu{sup 3+}-doped CaZrO{sub 3}-based compounds exhibited characteristic emissions of Eu{sup 3+} (f–f transition). The intensity of the main PL emission peak at 614 nm increased with Mg{sup 2+} co-doping, while it decreased with the amount of co-doped Sr{sup 2+}. The site substituted by Eu{sup 3+} cations in the CaZrO{sub 3}-based compounds was investigated by X-ray diffraction analysis and energy-dispersive X-ray analysis based on the electron channeling effects in transmission electron microscopy. The Eu{sup 3+} cations were determined to occupy mainly the B site (Zr{sup 4+}) in CaZrO{sub 3}. The dominant Eu{sup 3+} substitution site was also strongly influenced by the co-dopant, and the ionic radius of the co-dopant was identified as an important factor that determines the dominant Eu{sup 3+} substitution site.« less

  14. The CaGeO3 Ca3Fe2Ge3O12 garnet join: an experimental study

    NASA Astrophysics Data System (ADS)

    Iezzi, Gianluca; Boffa-Ballaran, Tiziana; McCammon, Catherine; Langenhorst, Falko

    2005-06-01

    Germanate garnets are often used as isostructural analogues of silicate garnets to provide insight into the crystal chemistry and symmetry of the less accessible natural garnet solid solutions. We synthesised two series of germanate garnets at 3 GPa along the joinVIIICa3VI(CaGe)IVGe3O12 VIIICa3VIFe2IVGe3O12 at 900 °C and 1,100 °C. Samples with compositions close to the CaGeO3 end-member consist of tetragonal garnet with a small amount of triclinic CaGe2O5. Samples with nominal compositions between XFe=0.4 and 1.0 consist of a mixture of tetragonal and cubic garnets; whereas, single-phase cubic garnets were obtained for compositions with XFe>1.2 (XFe gives the iron content expressed in atoms per formula unit, and varies between 0 and 2 along the join). Run products which were primarily single-phase garnet were investigated using Mössbauer spectroscopy. Spectra from samples synthesised at 1,100°C consist of one well-resolved doublet that can be assigned to Fe3+ in the octahedral site of the garnet structure. A second doublet, present primarily in samples synthesised at 900°C, can be assigned to Fe2+ at the octahedral sites of the garnet structure. The relative abundance of Fe2+ decreases with increasing iron content. Transmission electron microscopy analyses confirm this tendency and show that the garnets are essentially defect-free. The unit-cell parameters of tetragonal VIIICa3VI(CaGe)IVGe3O3 garnet decrease with increasing synthesis temperature, and the deviation from cubic symmetry becomes smaller. Cubic garnets show a linear decrease of unit-cell parameter with increasing iron content. The results are discussed in the context of iron incorporation into VIIIMg3VI(MgSi)IVSi3O3 majorite.

  15. High stability of electro-transport and magnetism against the A-site cation disorder in SrRuO3

    PubMed Central

    Wang, Y. L.; Liu, M. F.; Liu, R.; Xie, Y. L.; Li, X.; Yan, Z. B.; Liu, J.-M.

    2016-01-01

    It is known that the electro-transport and magnetism of perovskite alkaline-earth ruthenate oxides are sensitive to the lattice distortion associated with the A-site cation size. Orthorhombic CaRuO3 and cubic BaRuO3 exhibit distinctly different electro-transport and magnetic properties from orthorhombic SrRuO3. It has been suggested that SrRuO3 can be robust against some intrinsic/external perturbations but fragile against some others in terms of electro-transport and magnetism, and it is our motivation to explore such stability against the local site cation disorder. In this work, we prepare a set of SrRuO3-based samples with identical averaged A-site size but different A-site cation disorder (size mismatch) by Ca and Ba co-substitution of Sr. It is revealed that the electro-transport and magnetism of SrRuO3 demonstrate relatively high stability against this A-site cation disorder, characterized by the relatively invariable electrical and magnetic properties in comparison with those of SrRuO3 itself. A simple electro-transport network model is proposed to explain quantitatively the measured behaviors. The present work suggests that SrRuO3 as an itinerant electron ferromagnetic metal possesses relatively high robustness against local lattice distortion and cation occupation disorder. PMID:27297396

  16. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    PubMed

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  17. Risk factors and prognostic role of an electrical storm in patients after myocardial infarction with an implanted ICD for secondary prevention.

    PubMed

    Kwaśniewski, Wojciech; Filipecki, Artur; Orszulak, Michał; Orszulak, Witold; Urbańczyk, Dagmara; Roczniok, Robert; Trusz-Gluza, Maria; Mizia-Stec, Katarzyna

    2018-04-01

    The aim of our study was to determine the risk factors for electrical storm (ES) and to assess the impact of ES on the long-term prognosis in patients after myocardial infarction (MI) with an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). We retrospectively analyzed 416 patients with coronary artery disease after MI who had an implanted ICD for secondary prevention of SCD. Fifty (12%) patients had one or more incidents of an electrical storm - the ES (+) group. We matched the reference group of 47 patients from 366 ES (-) patients. We analyzed 3,408 episodes of ventricular arrhythmias: 3,148 ventricular tachyarrhythmic episodes in the ES (+) group (including 187 episodes of ES) and 260 in the ES (-) group. Multivariate logistic regression showed that inferior wall MI (RR = 3.98, 95% CI: 1.52-10.41) and the absence of coronary revascularization (RR = 2.92, 95% CI: 1.18-7.21) were independent predictors of ES ( p = 0.0014). During 6-year observation of 97 patients, there were 39 (40%) deaths: 25 (50%) subjects in the ES (+) group and 14 (30%) in the ES (-) group ( p = 0.036). Independent predictors of death were: the occurrence of ES (HR = 1.93), older age (HR = 1.06), and lower left ventricular ejection fraction (HR = 0.95) (for all p < 0.001). Electrical storm in patients after MI with ICD for secondary prevention is a relatively common phenomenon and has a negative prognostic significance. Myocardial infarction of the inferior wall and the absence of coronary revascularization are predisposing factors for the occurrence of an ES.

  18. Comparison of ICD-10R, DSM-IV-TR and DSM-5 in an Adult Autism Spectrum Disorder Diagnostic Clinic

    ERIC Educational Resources Information Center

    Wilson, C. Ellie; Gillan, Nicola; Spain, Deborah; Robertson, Dene; Roberts, Gedeon; Murphy, Clodagh M.; Maltezos, Stefanos; Zinkstok, Janneke; Johnston, Katie; Dardani, Christina; Ohlsen, Chris; Deeley, P. Quinton; Craig, Michael; Mendez, Maria A.; Happé, Francesca; Murphy, Declan G. M.

    2013-01-01

    An Autism Spectrum Disorder (ASD) diagnosis is often used to access services. We investigated whether ASD diagnostic outcome varied when DSM-5 was used compared to ICD-10R and DSM-IV-TR in a clinical sample of 150 intellectually able adults. Of those diagnosed with an ASD using ICD-10R, 56% met DSM-5 ASD criteria. A further 19% met DSM-5 (draft)…

  19. Microstructure and dielectric parameters of epitaxial SrRuO3/BaTiO3/SrRuO3 heterostructures

    NASA Astrophysics Data System (ADS)

    Boikov, Yu. A.; Claeson, T.

    2001-05-01

    Epitaxial films of ferroelectric barium titanate are desirable in a number of applications but their properties are inferior to those of bulk material. Relations between microstructure and dielectric properties may give better understanding of limitations. Trilayer heterostructures SrRuO3/BaTiO3/SrRuO3 were grown by laser ablation on (100)LaAlO3 and (100)MgO substrates. The BaTiO3 layer was granular in structure. When grown on (100)SrRuO3/(100)LaAlO3, it was preferentially a-axis oriented due to tensile mechanical stress. Using (100)MgO as a substrate, on the other hand, produced a mixture of about equal value of a-axis and c-axis oriented grains of BaTiO3. The dielectric permittivity, ɛ, of the BaTiO3 layer was almost twice as large, at T>200 K and f=100 kHz, for the LaAlO3 substrate as compared to the MgO one. Its maximum value (ɛ/ɛ0≈6200) depended on temperature of growth, grain size, and electric field and compares well with optimal values commonly used for ceramic material. The maximum in the ɛ(T) shifted from about 370 to 320 K when the grain size in the BaTiO3 film decreased from 100 to 40 nm. At T<300 K, hysteresis loops in polarization versus electric field were roughly symmetric. The BaTiO3 films grown on (100)SrRuO3/(100)MgO exhibit the largest remnant polarizations and coercive fields in the temperature range 100-380 K.

  20. Spectral Weight Redistribution in ( LaNiO 3 ) n / ( LaMnO 3 ) 2 Superlattices from Optical Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Pietro, P.; Hoffman, J.; Bhattacharya, A.

    2015-04-01

    We have studied the optical properties of four (LaNiO3)(n)/(LaMnO3)(2) superlattices (SL) (n = 2, 3, 4, 5) on SrTiO3 substrates. We have measured the reflectivity at temperatures from 20 to 400 K, and extracted the optical conductivity through a fitting procedure based on a Kramers-Kronig consistent Lorentz-Drude model. With increasing LaNiO3 thickness, the SLs undergo an insulator-to-metal transition (IMT) that is accompanied by the transfer of spectral weight from high to low frequency. The presence of a broad midinfrared band, however, shows that the optical conductivity of the (LaNiO3)(n)/(LaMnO3)(2) SLs is not a linear combination of the LaMnO3 and LaNiO3more » conductivities. Our observations suggest that interfacial charge transfer leads to an IMT due to a change in valence at the Mn and Ni sites.« less

  1. [Study of compatibility of psychiatric diagnoses with ICD-10 diagnostic criteria using the SCAN questionnaire].

    PubMed

    Adamowski, Tomasz; Kiejna, Andrzej; Hadryś, Tomasz

    2006-01-01

    Authors aimed at testing whether psychiatrists in their diagnostic process obeyed strict ICD-10 diagnostic criteria. Diagnoses made by psychiatrists at discharge were compared with those of SCAN ver.2.1 on admission. Diagnoses obtained by SCAN I-Shell program were compared with clinical diagnoses obtained by psychiatrists in the psychiatric wards according to ICD-10 criteria on 3 levels: diagnostic group (Fc), diagnostic class (Fcc), and diagnostic category (Fcc.c). Validity assessment was obtained with Cohen's Kappa coefficient, sensitivity, specificity and Yule's Y coefficient. On the diagnostic group level, Cohen's kappa was 0.14-0.65, Yule's Y 0.57-0.71. Sensitivity 0.69-0.95 and specificity 0.41-0.94. In psychotic disorders group F2 kappa was 0.65, Yule's Y 0.71, sensitivity 0.69, specificity 0.94. In affective disorders group F3 kappa was 0.31, Yule's Y 0.57, sensitivity 0.95, specificity 0.41. In neurotic disorders group F4 kappa was low 0.14, Yule's Y 0.62, sensitivity 0.95, specificity 0.50. The study showed a higher level of agreement between SCAN and clinical diagnoses in the group of psychotic disorders with exception of schizoaffective disorders, and lower agreement rates in the group of affective and neurotic disorders where the number of SCAN diagnoses outweighed that of the clinical ones. It could be the result of systematic faults in the coding of diagnoses.

  2. The influence of repressor DNA binding site architecture on transcriptional control.

    PubMed

    Park, Dan M; Kiley, Patricia J

    2014-08-26

    How the architecture of DNA binding sites dictates the extent of repression of promoters is not well understood. Here, we addressed the importance of the number and information content of the three direct repeats (DRs) in the binding and repression of the icdA promoter by the phosphorylated form of the global Escherichia coli repressor ArcA (ArcA-P). We show that decreasing the information content of the two sites with the highest information (DR1 and DR2) eliminated ArcA binding to all three DRs and ArcA repression of icdA. Unexpectedly, we also found that DR3 occupancy functions principally in repression, since mutation of this low-information-content site both eliminated DNA binding to DR3 and significantly weakened icdA repression, despite the fact that binding to DR1 and DR2 was intact. In addition, increasing the information content of any one of the three DRs or addition of a fourth DR increased ArcA-dependent repression but perturbed signal-dependent regulation of repression. Thus, our data show that the information content and number of DR elements are critical architectural features for maintaining a balance between high-affinity binding and signal-dependent regulation of icdA promoter function in response to changes in ArcA-P levels. Optimization of such architectural features may be a common strategy to either dampen or enhance the sensitivity of DNA binding among the members of the large OmpR/PhoB family of regulators as well as other transcription factors. In Escherichia coli, the response regulator ArcA maintains homeostasis of redox carriers under O2-limiting conditions through a comprehensive repression of carbon oxidation pathways that require aerobic respiration to recycle redox carriers. Although a binding site architecture comprised of a variable number of sequence recognition elements has been identified within the promoter regions of ArcA-repressed operons, it is unclear how this variable architecture dictates transcriptional regulation. By

  3. Medical Surveillance Monthly Report (MSMR). Volume 13, Number 2, February/March 2007

    DTIC Science & Technology

    2007-03-01

    13/No. 2 1 10 100 1,000 10,000 100,000 Influenza Varicella Hep B Pertussis Hep A Mumps Meningococcal disease Vaccine-preventable disease R ep or te... pertussis (ICD- 9: 033), mumps (ICD-9: 072), influenza (ICD-9: 487), hepatitis B (ICD-9: 070.2, 070.3), and hepatitis A (ICD- 9: 070.0, 070.1) were defined by...Influenza Varicella Hep B w/o coma Pertussis Hep A w/o coma MSMR 17Vol. 13/No. 2 conditions should account for potential changes in case ascertainment and

  4. Dynamics of CrO 3 –Fe 2 O 3 Catalysts during the High-Temperature Water-Gas Shift Reaction: Molecular Structures and Reactivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keturakis, Christopher J.; Zhu, Minghui; Gibson, Emma K.

    2016-06-13

    A series of supported CrO 3/Fe 2O 3 catalysts were investigated for the high-temperature water-gas shift (WGS) and reverse-WGS reactions and extensively characterized using in situ and operando IR, Raman, and XAS spectroscopy during the high-temperature WGS/RWGS reactions. The in situ spectroscopy examinations reveal that the initial oxidized catalysts contain surface dioxo (O=) 2Cr 6+O 2 species and a bulk Fe 2O 3 phase containing some Cr 3+ substituted into the iron oxide bulk lattice. Operando spectroscopy studies during the high-temperature WGS/RWGS reactions show that the catalyst transforms during the reaction. The crystalline Fe 2O 3 bulk phase becomes Femore » 3O 4 ,and surface dioxo (O=) 2Cr 6+O 2 species are reduced and mostly dissolve into the iron oxide bulk lattice. Consequently, the chromium–iron oxide catalyst surface is dominated by FeO x sites, but some minor reduced surface chromia sites are also retained. The Fe 3–-xCr xO 4 solid solution stabilizes the iron oxide phase from reducing to metallic Fe0 and imparts an enhanced surface area to the catalyst. Isotopic exchange studies with C 16O 2/H 2 → C 18O 2/H 2 isotopic switch directly show that the RWGS reaction proceeds via the redox mechanism and only O* sites from the surface region of the chromium–iron oxide catalysts are involved in the RWGS reaction. The number of redox O* sites was quantitatively determined with the isotope exchange measurements under appropriate WGS conditions and demonstrated that previous methods have undercounted the number of sites by nearly 1 order of magnitude. The TOF values suggest that only the redox O* sites affiliated with iron oxide are catalytic active sites for WGS/RWGS, though a carbonate oxygen exchange mechanism was demonstrated to exist, and that chromia is only a textural promoter that increases the number of catalytic active sites without any chemical promotion effect.« less

  5. Effects of ion doping at different sites on electrical properties of multiferroic BiFeO3 ceramics

    NASA Astrophysics Data System (ADS)

    Yu, Benfang; Li, Meiya; Liu, Jun; Guo, Dongyun; Pei, Ling; Zhao, Xingzhong

    2008-03-01

    Pure, La3+ doped at A site, V5+ doped at B site, and La3+ and V5+ co-doped multiferroic BiFeO3 ceramics: BiFeO3 (BFO), Bi0.85La0.15FeO3 (BLF), BiFe0.97V0.03O3 (BFV), Bi0.85La0.15Fe0.97V0.03O3 (BLFV), etc were successfully prepared by a rapid liquid sintering technique. X-ray diffraction indicated that these ceramics were of polycrystalline perovskite structures, accompanied with a tiny residual Bi2O3 phase. It was found that, among these ceramics, BLFV ceramic exhibited the best electrical properties. The leakage current density of BLFV ceramic was only 2.1 × 10-6 A cm-2 at 10 kV cm-1, two and one orders of magnitude lower than those of the BLF and BFV ceramics, respectively. In the measuring frequency of 4 KHz-1 MHz, the dielectric constants and losses of this sample exhibited slight variation and the lowest loss tangent was 0.08. The sample had a relatively saturated ferroelectric hysteresis loop. These suggested that the co-doped BiFeO3 ceramic by La3+ and V5+ at A and B sites showed advantages in application over the pure BFO, doped BLF and BFV ceramics, respectively.

  6. Data management procedures for Tiepoint Registration, pre and post processing, and ICD116

    NASA Technical Reports Server (NTRS)

    Nowakowski, B. S.

    1983-01-01

    The data management procedures for tiepoint registration, pre and post processing, and "ICD116' are described. With each procedure description, the pertinent execs are listed and purposes defined. An example run of each of the 32 execs is included with user inputs identified.

  7. Phase equilibria, crystal structures, and dielectric anomaly in the BaZrO 3-CaZrO 3 system

    NASA Astrophysics Data System (ADS)

    Levin, Igor; Amos, Tammy G.; Bell, Steven M.; Farber, Leon; Vanderah, Terrell A.; Roth, Robert S.; Toby, Brian H.

    2003-11-01

    Phase equilibria in the (1- x)BaZrO 3- xCaZrO 3 system were analyzed using a combination of X-ray and neutron powder diffraction, and transmission electron microscopy. The proposed phase diagram features two extended two-phase fields containing mixtures of a Ba-rich cubic phase and a tetragonal, or orthorhombic Ca-rich phase, all having perovskite-related structures. The symmetry differences in the Ca-rich phases are caused by different tilting patterns of the [ZrO 6] octahedra. In specimens quenched from 1650°C, CaZrO 3 dissolves only a few percent of Ba, whereas the solubility of Ca in BaZrO 3 is approximately 30 at% . The BaZrO 3-CaZrO 3 system features at least two tilting phase transitions, Pm3 m→ I4/ mcm and I4/ mcm→ Pbnm. Rietveld refinements of the Ba 0.8Ca 0.2ZrO 3 structure using variable-temperature neutron powder diffraction data confirmed that the Pm3 m→ I4/ mcm transition corresponds to a rotation of octahedra about one of the cubic axes; successive octahedra along this axis rotate in opposite directions. In situ variable-temperature electron diffraction studies indicated that the transition temperature increases with increasing Ca-substitution on the A-sites, from approximately -120°C at 5 at% Ca to 225°C at 20 at% Ca. Dielectric measurements revealed that the permittivity increases monotonically from 36 for BaZrO 3 to 53 for Ba 0.9Ca 0.1ZrO 3, and then decreases to 50 for Ba 0.8Ca 0.2ZrO 3. This later specimen was the Ca-richest composition for which pellets could be quenched from the single-phase cubic field with presently available equipment. Strongly non-monotonic behavior was also observed for the temperature coefficient of resonant frequency; however, in this case, the maximum occurred at a lower Ca concentration, 0.05⩽ x⩽0.1. The non-linear behavior of the dielectric properties was attributed to two competing structural effects: a positive effect associated with substitution of relatively small Ca cations on the A-sites, resulting

  8. Structure and properties of CdO-B2O3 and CdO-MnO-B2O3 glasses; Criteria of getting the fraction of four coordinated boron atoms from infrared spectra

    NASA Astrophysics Data System (ADS)

    Doweidar, H.; El-Damrawi, G.; El-Stohy, Sh.

    2017-11-01

    IR spectra of CdO-B2O3 and xCdO·(50 - x)MnO·50B2O3 glasses (0 ≤ x ≤ 50 mol%) have been analyzed. The fraction N4 of four coordinated boron atoms obtained from the integrated area under the IR spectra of CdO-B2O3 glasses is markedly higher than the reported NMR values. In both cases, N4 does not change with CdO content. The difference between N4 values of both techniques has been correlated with the relative absorption coefficient of BO4 unit with respect to BO3 unit, as suggested by Chryssikos et al. N4 data of xCdO·(50 - x)MnO·50B2O3 glasses could be used to calculate the fraction of modifier and former CdO and MnO in the borate matrix, as a function of composition. There is a linear increase in both the density and molar volume with increasing CdO content. The change has been correlated with the contribution of CdO and MnO. Electric conduction is assumed to take place via hopping of small polarons. There is a decrease in conductivity with increasing CdO concentration, which suggests that the electrons related to Cd sites are more localized than those at Mn sites.

  9. Comparison of validity of mapping between drug indications and ICD-10. Direct and indirect terminology based approaches.

    PubMed

    Choi, Y; Jung, C; Chae, Y; Kang, M; Kim, J; Joung, K; Lim, J; Cho, S; Sung, S; Lee, E; Kim, S

    2014-01-01

    Mapping of drug indications to ICD-10 was undertaken in Korea by a public and a private institution for their own purposes. A different mapping approach was used by each institution, which presented a good opportunity to compare the validity of the two approaches. This study was undertaken to compare the validity of a direct mapping approach and an indirect terminology based mapping approach of drug indications against the gold standard drawn from the results of the two mapping processes. Three hundred and seventy-five cardiovascular reference drugs were selected from all listed cardiovascular drugs for the study. In the direct approach, two experienced nurse coders mapped the free text indications directly to ICD-10. In the indirect terminology based approach, the indications were extracted and coded in the Korean Standard Terminology of Medicine. These terminology coded indications were then manually mapped to ICD-10. The results of the two approaches were compared to the gold standard. A kappa statistic was calculated to see the compatibility of both mapping approaches. Recall, precision and F1 score of each mapping approach were calculated and analyzed using a paired t-test. The mean number of indications for the study drugs was 5.42. The mean number of ICD-10 codes that matched in direct approach was 46.32 and that of indirect terminology based approach was 56.94. The agreement of the mapping results between the two approaches were poor (kappa = 0.19). The indirect terminology based approach showed higher recall (86.78%) than direct approach (p < 0.001). However, there was no difference in precision and F1 score between the two approaches. Considering no differences in the F1 scores, both approaches may be used in practice for mapping drug indications to ICD-10. However, in terms of consistency, time and manpower, better results are expected from the indirect terminology based approach.

  10. Rationale and design of the MONITOR-ICD study: a randomized comparison of economic and clinical effects of automatic remote MONITORing versus control in patients with Implantable Cardioverter Defibrillators.

    PubMed

    Zabel, Markus; Müller-Riemenschneider, Falk; Geller, J Christoph; Brachmann, Johannes; Kühlkamp, Volker; Dissmann, Rüdiger; Reinhold, Thomas; Roll, Stephanie; Lüthje, Lars; Bode, Frank; Eckardt, Lars; Willich, Stefan N

    2014-10-01

    Implantable cardioverter defibrillator (ICD) remote follow-up and ICD remote monitoring (RM) are established means of ICD follow-up. The reduction of the number of in-office visits and the time to decision is proven, but the true clinical benefit is still unknown. Cost and cost-effectiveness of RM remain leading issues for its dissemination. The MONITOR-ICD study has been designed to assess costs, cost-effectiveness, and clinical benefits of RM versus standard-care follow-up in a prospective multicenter randomized controlled trial. Patients indicated for single- or dual-chamber ICD are eligible for the study and are implanted an RM-capable Biotronik ICD (Lumax VR-T or Lumax DR-T; Biotronik SE & Co KG, Berlin, Germany). Implantable cardioverter defibrillator programming and alert-based clinical responses in the RM group are highly standardized by protocol. As of December 2011, recruitment has been completed, and 416 patients have been enrolled. Subjects are followed-up for a minimum of 12months and a maximum of 24months, ending in January 2013. Disease-specific costs from a societal perspective have been defined as primary end point and will be compared between RM and standard-care groups. Secondary end points include ICD shocks (including appropriate and inappropriate shocks), cardiovascular hospitalizations and cardiovascular mortality, and additional health economic end points. The MONITOR-ICD study will be an important randomized RM study to report data on a primary economic end point in 2014. Its results on ICD shocks will add to the currently available evidence on clinical benefit of RM. Copyright © 2014 Mosby, Inc. All rights reserved.

  11. The impact of changes in LVEF and renal function on the prognosis of ICD patients after elective device replacement.

    PubMed

    Vandenberk, Bert; Robyns, Tomas; Garweg, Christophe; Floré, Vincent; Foulon, Stefaan; Voros, Gabor; Ector, Joris; Willems, Rik

    2017-10-01

    A proportion of patients with an implantable cardioverter-defibrillator (ICD) in prevention of sudden cardiac death will only receive their first appropriate ICD therapy (AT) after device replacement. Clinical reassessment at the time of replacement could be helpful to guide the decision to replace or not in the future. All patients with an ICD for primary or secondary prevention in ischemic (ICM) or nonischemic cardiomyopathy were included in a single-center retrospective registry. The association of changes in left ventricular ejection fraction (LVEF; cut-off at 35%), worsening renal function (decrease in estimated glomerular filtration rate > 15 mL/min), and worsening New York Heart Association class at elective device replacement with mortality and AT was analyzed using adjusted Cox regression analysis. A total of 238 (33%) out of 727 patients received elective device replacement (86.1% male, 74.4% ICM, 42.9% primary prevention). During this replacement 20.2% received a device upgrade. The mean time to replacement was 6.4 ± 2.0 years and mean follow-up after replacement was 3.4 ± 3.0 years. Of patients who did not receive AT before replacement 23.1% received their first AT after replacement. Worsening renal function (hazard ratio [HR] 2.79, 95% confidence interval [CI] 1.50-5.18) and a consistently LVEF ≤35% compared to a consistently LVEF >35% (HR 2.15, 95% CI 1.10-4.19) at the time of replacement were independent predictors of mortality. Independent predictors of first AT after replacement could not be identified. Although reassessment of LVEF and renal function at replacement can be helpful in predicting total mortality, the clinical utility to guide reimplantation seemed limited. Our experience indicates that approximately 25% of patients received their first AT only after replacement. © 2017 Wiley Periodicals, Inc.

  12. Spectroscopic Properties of B2O3-PbO-Nd2O3 Glasses

    NASA Astrophysics Data System (ADS)

    Simon, V.; Ardelean, I.; Milea, I.; Peteanu, M.; Simon, S.

    Samples belonging to xNd2O3(100-x) [2B2O3·PbO] glass system, with 0≤ x≤ 40 mol%, are investigated by IR and UV-VIS spectroscopies in order to obtain evidence for the influence of Nd2O3 on the local order from 2B2O3·PbO glass matrix. Besides the IR absorption bands characteristic to lead and boron arrangements, typical absorption lines of Nd3+ ions around 4000 cm-1 and 6000 cm-1 are recorded. The 6000 cm-1 band appears only for the samples with x≥25 mol% Nd2O3. The split of some UV-VIS absorption bands arising from transitions of neodymium ions in doublet lines as well as the shift of the absorption bands as the Nd2O3 content increases denote the influence of the lead-borate matrix on the radiative transitions of the lanthanide ion.

  13. Female-specific education, management, and lifestyle enhancement for implantable cardioverter defibrillator patients: the FEMALE-ICD study.

    PubMed

    Vazquez, Lauren D; Conti, Jamie B; Sears, Samuel F

    2010-09-01

    Significant rates of psychological distress occur in implantable cardioverter defibrillator (ICD) patients. Research has demonstrated that women are particularly at risk for developing distress and warrant psychosocial attention. The major objectives were to implement and test the effectiveness of a female-specific psychosocial group intervention on disease-specific quality of life outcomes in outpatient female ICD recipients versus a wait-list control group. Twenty-nine women were recruited for the study. Fourteen women were randomized to the intervention group and participated in a psychosocial intervention focused on female-specific issues; 15 were randomized to the wait-list control group. All women completed individual psychological batteries at baseline and at 1-month follow-up measuring shock anxiety and device acceptance. Pre-post measures of shock anxiety demonstrated a significant time by group interaction effect with the intervention group having a significantly greater decrease (Pillai's trace = 5.58, P = 0.026). A significant interaction effect (Pillai's trace = 5.05, P = 0.046) was found, such that women under the age of 50 experienced greater reduction in shock anxiety than their middle-aged cohorts. Pre-post measures of device acceptance revealed a significant time by group interaction effect with the intervention group having significantly greater increases (Pillai's trace = 5.80, P = 0.023). Structured interventions for female ICD patients involving ICD-specific education, cognitive behavioral therapy strategies, and group social support provide improvements in shock anxiety and device acceptance at 1-month re-assessment. Young women appear to be an at-risk subgroup of this population and may experience more benefit from psychosocial treatment targeting device-specific concerns. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  14. An X-ray absorption spectroscopic study of the metal site preference in Al1-xGaxFeO3

    NASA Astrophysics Data System (ADS)

    Walker, James D. S.; Grosvenor, Andrew P.

    2013-01-01

    Magnetoelectric materials have potential for being introduced into next generation technologies, especially memory devices. The AFeO3 (Pna21; A=Al, Ga) system has received attention to better understand the origins of magnetoelectric coupling. The magnetoelectric properties this system exhibits depend on the amount of anti-site disorder present, which is affected by the composition and the method of synthesis. In this study, Al1-xGaxFeO3 was synthesized by the ceramic method and studied by X-ray absorption spectroscopy. Al L2,3-, Ga K-, and Fe K-edge spectra were collected to examine how the average metal coordination number changes with composition. Examination of XANES spectra from Al1-xGaxFeO3 indicate that with increasing Ga content, Al increasingly occupies octahedral sites while Ga displays a preference for occupying the tetrahedral site. The Fe K-edge spectra indicate that more Fe is present in the tetrahedral site in AlFeO3 than in GaFeO3, implying more anti-site disorder is present in AlFeO3.

  15. Quantifying the electronic reconstruction in LaTiO3/LaNiO3/(LaAlO3)3 heterostructures using RIXS

    NASA Astrophysics Data System (ADS)

    Fabbris, Gilberto; Disa, Ankit S.; Ismail-Beigi, Sohab; Walker, Frederick J.; Ahn, Charles H.; Pelliciari, Jonathan; Huang, Yaobo; Schmitt, Thorsten; Xu, Lei; Hozoi, Liviu; van den Brink, Jeroen; Dean, Mark

    A novel approach for manipulating the 3d state in transition metal oxide heterostructures has emerged with the growth of trilayer nickelate LaTiO3/LaNiO3/(LaAlO3)3 (LTNAO). This heterostructure induces a striking reconstruction of the LaNiO3 electronic structure, which is due to a combination of charge transfer from Ti's 3d state and octahedral elongation along the c axis. We use resonant inelastic x-ray scattering (RIXS) experiments at Ni L2,3 and O K edges to spectroscopically resolve the LTNAO electronic structure. Surprisingly, our results show that the octahedral elongation generates minor changes in crystal fields at Ni's 3d state compared to bulk LaNiO3. Instead, heterostructuring creates an anisotropic reconstruction of the Ni 3d - O 2p hybridization. The x2-y2 orbital is significantly more hybridized with O p, leading to a 3z2-r2/x2-y2 hole ratio of ~0.55 and large orbital polarization as measured by x-ray absorption spectroscopy. This work establishes RIXS as an ultra-sensitive probe of complex oxide heterostructures. Work at BNL was supported by the US Department of Energy under Award No DEAC02-98CH10886 and under Early Career Award No 20878.

  16. Mental health professionals' natural taxonomies of mental disorders: implications for the clinical utility of the ICD-11 and the DSM-5.

    PubMed

    Reed, Geoffrey M; Roberts, Michael C; Keeley, Jared; Hooppell, Catherine; Matsumoto, Chihiro; Sharan, Pratap; Robles, Rebeca; Carvalho, Hudson; Wu, Chunyan; Gureje, Oye; Leal-Leturia, Itzear; Flanagan, Elizabeth H; Correia, João Mendonça; Maruta, Toshimasa; Ayuso-Mateos, José Luís; de Jesus Mari, Jair; Xiao, Zeping; Evans, Spencer C; Saxena, Shekhar; Medina-Mora, María Elena

    2013-12-01

    To examine the conceptualizations held by psychiatrists and psychologists around the world of the relationships among mental disorders in order to inform decisions about the structure of the classification of mental and behavioral disorders in World Health Organization's International Classification of Diseases and Related Health Problems 11th Revision (ICD-11). 517 mental health professionals in 8 countries sorted 60 cards containing the names of mental disorders into groups of similar disorders, and then formed a hierarchical structure by aggregating and disaggregating these groupings. Distance matrices were created from the sorting data and used in cluster and correlation analyses. Clinicians' taxonomies were rational, interpretable, and extremely stable across countries, diagnostic system used, and profession. Clinicians' consensus classification structure was different from ICD-10 and the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders 4th Edition (DSM-IV), but in many respects consistent with ICD-11 proposals. The clinical utility of the ICD-11 may be improved by making its structure more compatible with the common conceptual organization of mental disorders observed across diverse global clinicians. © 2013 Wiley Periodicals, Inc.

  17. Polaronic deformation at the Fe2+/3 + impurity site in Fe:LiNbO3 crystals

    NASA Astrophysics Data System (ADS)

    Sanson, A.; Zaltron, A.; Argiolas, N.; Sada, C.; Bazzan, M.; Schmidt, W. G.; Sanna, S.

    2015-03-01

    Iron doped LiNbO3 crystals with different iron valence states are investigated. An extended x-ray absorption fine structure (EXAFS) spectroscopy study highlights evident changes in the local structure around iron that can be ascribed to the presence of small polarons. In particular, when a Fe3+ replaced a Li ion, the oxygen octahedron shrinked with respect to the pure material, with an average iron-oxygen bond value very similar to that of Fe2O3 hematite. When adding an electron, it localizes at the Fe site in a configuration very close to the atomic Fe d orbitals, inducing a relaxation of the oxygen cage. The same system was modelled by spin-polarized density functional theory (DFT). Several local as well as hybrid exchange-correlation functionals were probed on the bulk LiNbO3 structural properties. The computation is then extended to the case of hematite and finally to the Fe defect in LiNbO3. The calculations reproduced with good accuracy the large lattice relaxation of the oxygen ligands associated to the electronic capture at the Fe center that can be interpreted as due to the polaron formation. The calculations reproduce satisfactorily the available EXAFS data, and allow for the estimation of the polaron energies and the optical properties of the defect.

  18. Fabrication and enhanced photoluminescence properties of Sm3+-doped ZnO-Al2O3-B2O3-SiO2 glass derived willemite glass-ceramic nanocomposites

    NASA Astrophysics Data System (ADS)

    Tarafder, Anal; Molla, Atiar Rahaman; Mukhopadhyay, Sunanda; Karmakar, Basudeb

    2014-07-01

    The transparent willemite, Zn2SiO4 (ZS) glass-ceramic nanocomposites were prepared from melt-quench derived ZnO-Al2O3-B2O3-SiO2 (ZABS) precursor glass by an isothermal heat-treatment process. The generation of willemite crystal phase, size and morphology with increase in heat-treatment time was examined by X-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM) techniques. The average calculated crystallite size obtained from XRD is found to be in the range 80-120 nm. The decreased refractive index with increase in heat-treatment time attributed to partial replacement of ZnO4 units of willemite nanocrystals by AlO4 units and simultaneous generation of vacancies in the Zn-site. Fourier transform infrared (FTIR) reflection spectroscopy exhibits the structural evolution of willemite glass-ceramics. The photoluminescence spectra of Sm3+ ions exhibit emission transitions of 4G5/2 → 6HJ (J = 5/2, 7/2, 9/2, 11/2) and its excitation spectra shows an intense absorption band at 402 nm. These spectra reveal that the luminescence performance of the glass-ceramic nanocomposites is enhanced up to 14-fold with crystallization into willemite.

  19. High-Temperature Thermoelectric Properties of (1 - x) SrTiO3 - ( x) La1/3NbO3 Ceramic Solid Solution

    NASA Astrophysics Data System (ADS)

    Srivastava, Deepanshu; Azough, F.; Molinari, M.; Parker, S. C.; Freer, R.

    2015-06-01

    Ceramics based on SrTiO3 are of growing interest as thermoelectric materials because of their high-temperature stability and non-toxicity. Substitution of La and Nb into the perovskite structure provides opportunities to control both the microstructure and properties. Ceramic solid solutions of (1 - x) SrTiO3 - ( x) La1/3NbO3 were prepared by the mixed oxide route, using compositional steps of x = 0.1. Pressed pellets were sintered at temperatures of 1573 K to 1723 K in air. Addition of aliovalent ions (La3+, Nb5+) on the A/B sites (Sr2+, Ti4+) led to A-Site cation deficiency in the stoichiometric compositions and other defect structures which increased carrier concentration. A maximum ZT of 0.004 was obtained for the x = 0.2 stoichiometric sample, although much higher ZT values are possible by sample reduction.

  20. Infrared and Raman spectroscopy of [Pb(Zn1/3Nb2/3)O3]0.92-[PbTiO3]0.08 and [Pb(Mg1/3Nb2/3)O3]0.71-[PbTiO3]0.29 single crystals

    NASA Astrophysics Data System (ADS)

    Kamba, S.; Buixaderas, E.; Petzelt, J.; Fousek, J.; Nosek, J.; Bridenbaugh, P.

    2003-01-01

    Far-infrared reflectivity spectra of [Pb(Zn1/3Nb2/3)O3]0.92-[PbTiO3]0.08 and [Pb(Mg1/3Nb2/3)O3]0.71-[PbTiO3]0.29 single crystals were investigated between 10 and 530 K, micro-Raman spectra were recorded between 300 and 800 K. No phonon softening was observed near either of the ferroelectric phase transitions. The low-frequency dielectric anomaly in the paraelectric phase is caused by contribution of dynamic polar nanoclusters with the main dispersion in the microwave range. Infrared and Raman spectra confirm the locally doubled unit cell (Zprim=2) in the paraelectric and ferroelectric phases due to the ordering in the perovskite B sites and occurrence of polar nanoclusters in the paraelectric phase. The lowest-frequency transverse optical (TO1) phonon mode active in the infrared spectra is underdamped in contrast to the recent result of inelastic neutron scattering, where no TO1 mode could be observed for the wave vectors q⩽0.2 Å-1. This discrepancy was explained by different q vectors probed in infrared and neutron experiments. The infrared probe couples with very long-wavelength phonons (q≈10-5 Å-1) which see the homogeneous medium averaged over the nanoclusters, whereas the neutron probe couples with phonons whose wavelength is comparable to the nanocluster size (q⩾10-2 Å-1).

  1. Optimization and simplification of the Allergic and Hypersensitivity conditions classification for the ICD-11.

    PubMed

    Tanno, L K; Calderon, M A; Demoly, P

    2016-05-01

    Since 2013, an international collaboration of Allergy Academies, including first the World Allergy Organization (WAO), the American Academy of Allergy Asthma and Immunology (AAAAI), and the European Academy of Allergy and Clinical Immunology (EAACI), and then the American College of Allergy, Asthma and Immunology (ACAAI), the Latin American Society of Allergy, Asthma and Immunology (SLAAI), and the Asia Pacific Association of Allergy, Asthma and Clinical Immunology (APAAACI), has spent tremendous efforts to have a better and updated classification of allergic and hypersensitivity conditions in the forthcoming International Classification of Diseases (ICD)-11 version by providing evidences and promoting actions for the need for changes. The latest action was the implementation of a classification proposal of hypersensitivity/allergic diseases built by crowdsourcing the Allergy Academy leaderships. Following bilateral discussions with the representatives of the ICD-11 revision, a face-to-face meeting was held at the United Nations Office in Geneva and a simplification process of the hypersensitivity/allergic disorders classification was carried out to better fit the ICD structure. We are here presenting the end result of what we consider to be a model of good collaboration between the World Health Organization and a specialty. We strongly believe that the outcomes of all past and future actions will impact positively the recognition of the allergy specialty as well as the quality improvement of healthcare system for allergic and hypersensitivity conditions worldwide. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Renal sympathetic denervation guided by renal nerve stimulation to treat ventricular arrhythmia in CKD patients with ICD

    PubMed Central

    Kiuchi, Márcio Galindo; Chen, Shaojie; Rodrigues Paz, Luis Marcelo; Pürerfellner, Helmut

    2017-01-01

    Chronic kidney disease (CKD) patients on stage 4 present greater risk rates for malignant ventricular arrhythmia events. This study examined patients with CKD in stages 1, 2, 3 and 4, left ventricular dysfunction and automatic implantable cardioverter-defibrillator (ICD). Our goal was to record the appropriate therapies, “Anti-tachycardia Therapy Pacing” (ATP) and shock events during the 18 months of follow-up and compare the incidence and severity of these at different stages of CKD, mainly in patients with CKD stage 4 underwent renal sympathetic denervation (RSD) guided by renal nerve stimulation (RNS). One hundred and fifteen patients were evaluated once every three months till 18 months of follow-up. The arrhythmic events were assessed at each follow-up visit. Comparing the groups, we can see the number of ATP and shock events recorded by ICD during 18 months of follow-up, and differences in the number of therapeutic events between the various stages of CKD. The hazard ratio (HR), 95% confidence interval (CI) and P value for ATP and shock events between all the CKD stages were evaluated by the log-rank/Mantel-Haenszel test. At the 18th month of follow-up, 75% of patients with CKD stage 4 received ATP, and 70% were treated with shock while only 20% of the subjects with CKD stage 4 that were submitted to RSD received ATP and 20% were treated with shock, P<0.0001 and P=0.0002, respectively. In our study, a decline occurred in the incidence of arrhythmias, and therefore, appropriate ICD therapies in advanced stages of CKD, reducing the risk rates for these events in patients with CKD on stage 4 after RSD guided by RNS in comparison to the other CKD stages. Our results suggest that RSD can control the higher incidence of malignant arrhythmias in advanced CKD stages. PMID:28415795

  3. Variation in post-traumatic response: the role of trauma type in predicting ICD-11 PTSD and CPTSD symptoms.

    PubMed

    Hyland, Philip; Murphy, Jamie; Shevlin, Mark; Vallières, Frédérique; McElroy, Eoin; Elklit, Ask; Christoffersen, Mogens; Cloitre, Marylène

    2017-06-01

    The World Health Organization's 11th revision to the International Classification of Diseases manual (ICD-11) will differentiate between two stress-related disorders: PTSD and Complex PTSD (CPTSD). ICD-11 proposals suggest that trauma exposure which is prolonged and/or repeated, or consists of multiple forms, that also occurs under circumstances where escape from the trauma is difficult or impossible (e.g., childhood abuse) will confer greater risk for CPTSD as compared to PTSD. The primary objective of the current study was to provide an empirical assessment of this proposal. A stratified, random probability sample of a Danish birth cohort (aged 24) was interviewed by the Danish National Centre for Social Research (N = 2980) in 2008-2009. Data from this interview were used to generate an ICD-11 symptom-based classification of PTSD and CPTSD. The majority of the sample (87.1%) experienced at least one of eight traumatic events spanning childhood and early adulthood. There was some indication that being female increased the risk for both PTSD and CPTSD classification. Multinomial logistic regression results found that childhood sexual abuse (OR = 4.98) and unemployment status (OR = 4.20) significantly increased risk of CPTSD classification as compared to PTSD. A dose-response relationship was observed between exposure to multiple forms of childhood interpersonal trauma and risk of CPTSD classification, as compared to PTSD. Results provide empirical support for the ICD-11 proposals that childhood interpersonal traumatic exposure increases risk of CPTSD symptom development.

  4. Operational Assessment of ICDS Scheme at Grass Root Level in a Rural Area of Eastern India: Time to Introspect

    PubMed Central

    Sahoo, Jyotiranjan; Mahajan, Preetam B; Bhatia, Vikas; Patra, Abhinash K; Hembram, Dilip Kumar

    2016-01-01

    Introduction Integrated Child Development Service (ICDS), a flagship program of Government of India (GoI) for early childhood development hasn’t delivered the desired results since its inception four decades ago. This could be due to infrastructural problems, lack of awareness and proper utilization by the local people, inadequate program monitoring and corruption in food supplies, etc. This study is an audit of 36 Anganwadi centres at Khordha district, Odisha, to evaluate the implementation of the ICDS. Aim To assess operational aspects of ICDS program in a rural area of Odisha, in Eastern India. Materials and Methods A total of 36 out of 50 Anganwadi Centres (AWCs) were included in the study. We interviewed the Anganwadi Workers (AWW) and carried out observations on the AWCs using a checklist. We gathered information under three domains manpower resource, material resource and functional aspects of the AWC. Results Most of the AWCs were adequately staffed. Most of the AWWs were well educated. However, more than 85% of the AWCs did not have designated building for daily functioning which resulted in issues related to implementation of program. Water, toilet and electricity facilities were almost non-existent. Indoor air pollution posed a serious threat to the health of the children. Lack of play materials; lack of health assessment tools for promoting, monitoring physical and mental development; and multiple de-motivating factors within the work environment, eventually translated into lack of faith among the beneficiaries in the rural community. Conclusion Inadequate infrastructure and logistic supply were the most prominent issues found, which resulted in poor implementation of ICDS program. Strengthening of grass root level facilities based on need assessment, effective monitoring and supervision will definitely help in revamping the ICDS program in rural areas. PMID:28208890

  5. The validity of using ICD-9 codes and pharmacy records to identify patients with chronic obstructive pulmonary disease

    PubMed Central

    2011-01-01

    Background Administrative data is often used to identify patients with chronic obstructive pulmonary disease (COPD), yet the validity of this approach is unclear. We sought to develop a predictive model utilizing administrative data to accurately identify patients with COPD. Methods Sequential logistic regression models were constructed using 9573 patients with postbronchodilator spirometry at two Veterans Affairs medical centers (2003-2007). COPD was defined as: 1) FEV1/FVC <0.70, and 2) FEV1/FVC < lower limits of normal. Model inputs included age, outpatient or inpatient COPD-related ICD-9 codes, and the number of metered does inhalers (MDI) prescribed over the one year prior to and one year post spirometry. Model performance was assessed using standard criteria. Results 4564 of 9573 patients (47.7%) had an FEV1/FVC < 0.70. The presence of ≥1 outpatient COPD visit had a sensitivity of 76% and specificity of 67%; the AUC was 0.75 (95% CI 0.74-0.76). Adding the use of albuterol MDI increased the AUC of this model to 0.76 (95% CI 0.75-0.77) while the addition of ipratropium bromide MDI increased the AUC to 0.77 (95% CI 0.76-0.78). The best performing model included: ≥6 albuterol MDI, ≥3 ipratropium MDI, ≥1 outpatient ICD-9 code, ≥1 inpatient ICD-9 code, and age, achieving an AUC of 0.79 (95% CI 0.78-0.80). Conclusion Commonly used definitions of COPD in observational studies misclassify the majority of patients as having COPD. Using multiple diagnostic codes in combination with pharmacy data improves the ability to accurately identify patients with COPD. PMID:21324188

  6. Critical Evaluations and Thermodynamic Optimizations of the MnO-Mn2O3-SiO2 and FeO-Fe2O3-MnO-Mn2O3-SiO2 Systems

    NASA Astrophysics Data System (ADS)

    Kang, Youn-Bae; Jung, In-Ho

    2017-06-01

    A critical evaluation and thermodynamic modeling for thermodynamic properties of all oxide phases and phase diagrams in the Fe-Mn-Si-O system (MnO-Mn2O3-SiO2 and FeO-Fe2O3-MnO-Mn2O3-SiO2 systems) are presented. Optimized Gibbs energy parameters for the thermodynamic models of the oxide phases were obtained which reproduce all available and reliable experimental data within error limits from 298 K (25°C) to above the liquidus temperatures at all compositions covering from known oxide phases, and oxygen partial pressure from metal saturation to 0.21 bar. The optimized thermodynamic properties and phase diagrams are believed to be the best estimates presently available. Slag (molten oxide) was modeled using the modified quasichemical model in the pair approximation. Olivine (Fe2SiO4-Mn2SiO4) was modeled using two-sublattice model in the framework of the compound energy formalism (CEF), while rhodonite (MnSiO3-FeSiO3) and braunite (Mn7SiO_{12} with excess Mn2O3) were modeled as simple Henrian solutions. It is shown that the already developed models and databases of two spinel phases (cubic- and tetragonal-(Fe, Mn)3O4) using CEF [Kang and Jung, J. Phys. Chem. Solids (2016), vol. 98, pp. 237-246] can successfully be integrated into a larger thermodynamic database to be used in practically important higher order system such as silicate. The database of the model parameters can be used along with a software for Gibbs energy minimization in order to calculate any type of phase diagram section and thermodynamic properties.

  7. The impact of ICD-9 revascularization procedure codes on estimates of racial disparities in ischemic stroke.

    PubMed

    Boan, Andrea D; Voeks, Jenifer H; Feng, Wuwei Wayne; Bachman, David L; Jauch, Edward C; Adams, Robert J; Ovbiagele, Bruce; Lackland, Daniel T

    2014-01-01

    The use of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9) diagnostic codes can identify racial disparities in ischemic stroke hospitalizations; however, inclusion of revascularization procedure codes as acute stroke events may affect the magnitude of the risk difference. This study assesses the impact of excluding revascularization procedure codes in the ICD-9 definition of ischemic stroke, compared with the traditional inclusive definition, on racial disparity estimates for stroke incidence and recurrence. Patients discharged with a diagnosis of ischemic stroke (ICD-9 codes 433.00-434.91 and 436) were identified from a statewide inpatient discharge database from 2010 to 2012. Race-age specific disparity estimates of stroke incidence and recurrence and 1-year cumulative recurrent stroke rates were compared between the routinely used traditional classification and a modified classification of stroke that excluded primary ICD-9 cerebral revascularization procedures codes (38.12, 00.61, and 00.63). The traditional classification identified 7878 stroke hospitalizations, whereas the modified classification resulted in 18% fewer hospitalizations (n = 6444). The age-specific black to white rate ratios were significantly higher in the modified than in the traditional classification for stroke incidence (rate ratio, 1.50; 95% confidence interval [CI], 1.43-1.58 vs. rate ratio, 1.24; 95% CI, 1.18-1.30, respectively). In whites, the 1-year cumulative recurrence rate was significantly reduced by 46% (45-64 years) and 49% (≥ 65 years) in the modified classification, largely explained by a higher rate of cerebral revascularization procedures among whites. There were nonsignificant reductions of 14% (45-64 years) and 19% (≥ 65 years) among blacks. Including cerebral revascularization procedure codes overestimates hospitalization rates for ischemic stroke and significantly underestimates the racial disparity estimates in stroke

  8. Speaking the same language: underestimating financial impact when using diagnosis-related group versus ICD-9-based definitions for trauma inclusion criteria.

    PubMed

    Deppe, Sharon; Truax, Christopher B; Opalek, Judy M; Santanello, Steven A

    2009-04-01

    Hospital accounting methods use diagnosis-related group (DRG) data to identify patients and derive financial analyses and reports. The National Trauma Data Bank and trauma programs identify patients with trauma by International Classification of Diseases, Ninth Edition (ICD-9)-based definitions for inclusion criteria. These differing methods of identifying patients result in economic reports that vary significantly and fail to accurately identify the financial impact of trauma services. Routine financial data were collected for patients admitted to our Trauma Service from July 1, 2005 to June 30, 2006 using two methods of identifying the cases; by trauma DRGs and by trauma registry database inclusion criteria. The resulting data were compared and stratified to define the financial impact on hospital charges, reimbursement, costs, contribution to margin, downstream revenue, and estimated profit or loss. The results also defined the impact on supporting services, market share and total revenue from trauma admissions, return visits, discharged trauma alerts, and consultations. A total of 3,070 patients were identified by the trauma registry as meeting ICD-9 inclusion criteria. Trauma-associated DRGs accounted for 871 of the 3,070 admissions. The DRG-driven data set demonstrated an estimated profit of $800,000 dollars; the ICD-9 data set revealed an estimated 4.8 million dollar profit, increased our market share, and showed substantial revenue generated for other hospital service lines. Trauma DRGs fail to account for most trauma admissions. Financial data derived from DRG definitions significantly underestimate the trauma service line's financial contribution to hospital economics. Accurately identifying patients with trauma based on trauma database inclusion criteria better defines the business of trauma.

  9. A comparative study of photoconductivity in LaTiO3/SrTiO3 and LaAlO3/SrTiO3 2-DEG heterostructures

    NASA Astrophysics Data System (ADS)

    Rastogi, A.; Hossain, Z.; Budhani, R. C.

    2013-02-01

    Here we compare the growth temperature dependence of the response of LaTiO3/SrTiO3 and LaAlO3/SrTiO3 2D-electron gas (2-DEG) field effect structure to the optical radiation of near ultraviolet frequency and electrostatic gate field. For both the films the resistance of the channel increases significantly as growth temperature is lowered from 800 to 700 °C. These heterostructures show the photoconductivity (PC) simulated by UV light of λ ≤ 400 nm. The PC follows the stretched exponential dynamics. It is found that photo-response of the LaTiO3 films is prominent and has larger decay time constant as compare to LaAlO3 films. The effect of electric field on the photo-induced conducting state is also studied.

  10. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead.

    PubMed

    Lovelock, Joshua D; Premkumar, Ajay; Levy, Mathew R; Mengistu, Andenet; Hoskins, Michael H; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel R; Langberg, Jonathan J; Delurgio, David B

    2015-12-01

    St. Jude Riata/Riata ST defibrillator leads (St. Jude Medical, Sylmar, CA, USA) were recalled by the Food and Drug Administration in 2011 for an increased rate of failure. More than 227,000 leads were implanted and at least 79,000 patients still have active Riata leads. Studies have examined clinical predictors of lead failure in Riata leads, but none have addressed the effect of implantable cardioverter defibrillator (ICD) generator exchange on lead failure. The purpose of this study is to assess the effect of ICD generator exchange on the rate of electrical failure in the Riata lead at 1 year. A retrospective chart review was conducted in patients who underwent implantation of a Riata/Riata ST lead at one center. Patients with a functioning Riata lead (with/without externalized conductor) at the time of ICD exchange were compared to controls with Riata leads implanted for a comparable amount of time who did not undergo generator replacement. Riata leads were implanted in 1,042 patients prior to the recall and 153 of these patients underwent generator exchange without lead replacement. Conductor externalization was noted in 21.5% of Riata leads in the ICD exchange cohort, which was not different from the control group (19.2%; P = 0.32). Two leads failed in the first year after generator replacement (1.5%) which did not significantly differ from the control group (2.0%; P = 0.57). At change-out, 54% received a commanded shock (18.6 ± 0.9 J) that did not result in any change in the high-voltage lead impedance (46.1 ± 1.1 ohms). Conductor externalization was seen frequently in our cohort of patients. ICD generator exchange did not accelerate the rate of Riata lead failure at 1 year. Although both the control and the change-out cohorts failed at a rate much greater than nonrecalled leads, generator exchange did not appear to add to the problem. ©2015 Wiley Periodicals, Inc.

  11. Remote monitoring improves outcome after ICD implantation: the clinical efficacy in the management of heart failure (EFFECT) study.

    PubMed

    De Simone, Antonio; Leoni, Loira; Luzi, Mario; Amellone, Claudia; Stabile, Giuseppe; La Rocca, Vincenzo; Capucci, Alessandro; D'onofrio, Antonio; Ammendola, Ernesto; Accardi, Francesco; Valsecchi, Sergio; Buja, Gianfranco

    2015-08-01

    Internet-based remote interrogation systems have been shown to reduce emergency department and in-office visits in patients with implantable cardioverter defibrillators (ICDs), resulting in increased efficiency for healthcare providers. Nonetheless, studies sized to demonstrate the impact of remote monitoring on patients' outcome have been lacking. The EFFECT study was a multicentre clinical trial aimed at measuring and comparing the outcome of ICD patients conventionally followed-up by means of in-clinic visits (Standard arm) or by remote monitoring (Remote arm) in the clinical practice of 25 Italian centres. From 2011 to 2013, 987 consecutive patients were enrolled and followed up for at least 12 months. The primary endpoint was the rate of death and cardiovascular hospitalizations. Remote monitoring was adopted by 499 patients. Patients in the Standard and Remote arms did not differ significantly in terms of baseline clinical characteristics, except for a more frequent use of ICD with cardiac resynchronization therapy (CRT-D) in the Remote arm (48 vs. 36%, P < 0.001). One-year rates of the primary combined endpoint were 0.27 events/year for patients in the Standard arm and were 0.15 events/year for those in the Remote arm (incident rate ratio, 0.55; 95% CI, 0.41-0.73; P < 0.001). The endpoint rates in the Standard and Remote arms were 0.27 and 0.08 events/year, respectively, among CRT-D recipients (P < 0.001), and 0.28 vs. 0.21 among ICD patients (P = 0.094). The rates of in-office visits were 1.9 per year in the Standard arm and 1.7 per year in the Remote arm. Compared with the standard follow-up through in-office visits, remote monitoring is associated with reduced death and cardiovascular hospitalizations in patients with ICD in clinical practice. URL: http://clinicaltrials.gov/ Identifier: NCT01723865. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  12. Gender Incongruence of Childhood: Clinical Utility and Stakeholder Agreement with the World Health Organization's Proposed ICD-11 Criteria.

    PubMed

    Beek, Titia F; Cohen-Kettenis, Peggy T; Bouman, Walter P; de Vries, Annelou L C; Steensma, Thomas D; Witcomb, Gemma L; Arcelus, Jon; Richards, Christina; De Cuypere, Griet; Kreukels, Baudewijntje P C

    2017-01-01

    The World Health Organization (WHO) is revising the tenth version of the International Classification of Diseases and Related Health Problems (ICD-10). This includes a reconceptualization of the definition and positioning of Gender Incongruence of Childhood (GIC). This study aimed to: 1) collect the views of transgender individuals and professionals regarding the retention of the diagnosis; 2) see if the proposed GIC criteria were acceptable to transgender individuals and health care providers; 3) compare results between two countries with two different healthcare systems to see if these differences influence opinions regarding the GIC diagnosis; and 4) determine whether healthcare providers from high-income countries feel that the proposed criteria are clinically useful and easy to use. A total of 628 participants were included in the study: 284 from the Netherlands (NL; 45.2%), 8 from Flanders (Belgium; 1.3%), and 336 (53.5%) from the United Kingdom (UK). Most participants were transgender people (or their partners/relatives; TG) (n = 522), 89 participants were healthcare providers (HCPs) and 17 were both HCP and TG individuals. Participants completed an online survey developed for this study. Overall, the majority response from transgender participants (42.9%) was that if the diagnosis would be removed from the mental health chapter it should also be removed from the ICD-11 completely, while 33.6% thought it should remain in the ICD-11. Participants were generally satisfied with other aspects of the proposed ICD-11 GIC diagnosis: most TG participants (58.4%) thought the term Gender Identity Disorder should change, and most thought Gender Incongruence was an improvement (63.0%). Furthermore, most participants (76.1%) did not consider GIC to be a psychiatric disorder and placement in a separate chapter dealing with Gender and Sexual Health (the majority response in the NL and selected by 37.5% of the TG participants overall) or as a Z-code (the majority response

  13. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD

    PubMed Central

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B.; Bramsen, Rikke H.; Nielsen, Anni B. S.; Armour, Cherie; Andersen, Søren B.; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E.

    2017-01-01

    ABSTRACT Background: Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives: The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students (N = 4213), chronic pain patients (N = 573), and military personnel (N = 118). Results: Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions: The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD. PMID:29201287

  14. Does size really matter? A multisite study assessing the latent structure of the proposed ICD-11 and DSM-5 diagnostic criteria for PTSD.

    PubMed

    Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B; Bramsen, Rikke H; Nielsen, Anni B S; Armour, Cherie; Andersen, Søren B; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E

    2017-01-01

    Background : Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives : The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students ( N  = 4213), chronic pain patients ( N  = 573), and military personnel ( N  = 118). Results : Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions : The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD.

  15. Removal of nitrate and phosphate using chitosan/Al2O3/Fe3O4 composite nanofibrous adsorbent: Comparison with chitosan/Al2O3/Fe3O4 beads.

    PubMed

    Bozorgpour, Farahnaz; Ramandi, Hossein Fasih; Jafari, Pooya; Samadi, Saman; Yazd, Shabnam Sharif; Aliabadi, Majid

    2016-12-01

    In the present study the chitosan/Al 2 O 3 /Fe 3 O 4 composite nanofibrous adsorbent was prepared by electrospinning process and its application for the removal of nitrate and phosphate were compared with chitosan/Al 2 O 3 /Fe 3 O 4 composite bead adsorbent. The influence of Al 2 O 3 /Fe 3 O 4 composite content, pH, contact time, nitrate and phosphate initial concentrations and temperature on the nitrate and phosphate sorption using synthesized bead and nanofibrous adsorbents was investigated in a single system. The reusability of chitosan/Al 2 O 3 /Fe 3 O 4 composite beads and nanofibers after five sorption-desorption cycles were carried out. The Box-Behnken design was used to investigate the interaction effects of adsorbent dosage, nitrate and phosphate initial concentrations on the nitrate and phosphate removal efficiency. The pseudo-second-order kinetic model and known Freundlich and Langmuir isotherm models were used to describe the kinetic and equilibrium data of nitrate and phosphate sorption using chitosan/Al 2 O 3 /Fe 3 O 4 composite beads and nanofibers. The influence of other anions including chloride, fluoride and sulphate on the sorption efficiency of nitrate and phosphate was examined. The obtained results revealed the higher potential of chitosan/Al 2 O 3 /Fe 3 O 4 composite nanofibers for nitrate and phosphate compared with chitosan/Al 2 O 3 /Fe 3 O 4 composite beads. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Past, present and future of Integrated Child Development Services (I.C.D.S.).

    PubMed

    Lal, S; Sachar, R K

    1993-01-01

    India's Integrated Child Development Services (ICDS) was established in 33 projects in 1975 and is spread over 22 states; 67 additional projects were begun in 1977, and over the next 2 years; 100 additional projects were added. By 1991=92, coverage was almost 50% of the country with 2696 projects; the expectation is for 100% coverage by the year 2000. An infrastructure chart identifies the organization and integration between level and social welfare and health departments. Objectives are clearly identified and the departments functionally linked. Linkages are achieved by shared space and activities at various levels. Over the past 17 years, services have included minimum needs programs, integrated rural development and poverty alleviation, national health policy and education policy, universal immunization, and the development of women and children in rural areas. ICDS is sponsored 100% by the status and uniquely relies on the honorary anganwadi worker (AWW), who is a woman, recruited and chosen by the community, aged 21-45 years and middle-school educated. The AWW was responsibility for 2000 households or 1000 persons in rural areas and 700 persons in tribal areas. The AWW is crucial to the functioning of the program and receives an honorarium of Rs. 225-275/month for implementing the ICDs program; AWWs have helpers who are paid Rs. 110/month. Training over a 3-year period is conducted at the Bal Sevika Training Institute by the Indian Council of Child Welfare. Additional health personnel and their role and the number of persons/per area AWWS are responsible for, equipment, and functions are also described. The AWW is responsible for nonformal preschool education, organization of supplementary nutrition feeding, health and nutrition education of women and families, immunization of women and children, treatment and referral of common illnesses, growing monitoring, and community participation. Presently, there are 2506 central sector projects and 190 state sector

  17. Substance use disorders: Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10).

    PubMed

    Hasin, Deborah; Hatzenbuehler, Mark L; Keyes, Katherine; Ogburn, Elizabeth

    2006-09-01

    Two major nomenclatures, Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10), currently define substance use disorders for broad audiences of users with different training, experience and interests. A comparison of these definitions and their implications for DSM-V and ICD-11 has not been available. The background for the dependence concept and abuse, harmful use, withdrawal, substance-induced disorders and remission and other substance-related conditions is reviewed. Reliability evidence is presented, as is validity evidence from approaches including psychometric, genetic and animal studies. The relevance of the DSM-IV and ICD-10 compared to alternative systems (e.g. the Addiction Severity Index) is considered. Reliability and psychometric validity evidence for substance dependence is consistently strong, but more mixed for abuse and harmful use. Findings on the genetics of alcohol disorders support the validity of the dependence concept, while animal studies underscore the centrality of continued use despite negative consequences to the concept of dependence. While few studies on substance-induced disorders have been conducted, those published show good reliability and validity when elements of DSM-IV and ICD-10 are combined. Dependence in DSM-V and ICD-11 should be retained, standardizing both criteria sets and adding a severity measure. The consequences of heavy use should be measured independently of dependence; add cannabis withdrawal if further research supports existing evidence; conduct further studies of the substance-induced psychiatric categories; standardize their criteria across DSM-V and ICD-11; develop a theoretical basis for better remission criteria; consider changing substance 'abuse' to substance 'dysfunction disorder'; and conduct clinician education on the value of the diagnostic criteria.

  18. ICD-11 Prevalence Rates of Posttraumatic Stress Disorder and Complex Posttraumatic Stress Disorder in a German Nationwide Sample.

    PubMed

    Maercker, Andreas; Hecker, Tobias; Augsburger, Mareike; Kliem, Sören

    2018-04-01

    Prevalence rates are still lacking for posttraumatic stress disorder (PTSD) and complex PTSD (CPTSD) diagnoses based on the new ICD-11 criteria. In a nationwide representative German sample (N = 2524; 14-99 years), exposure to traumatic events and symptoms of PTSD or CPTSD were assessed with the International Trauma Questionnaire. A clinical variant of CPTSD with a lower threshold for core PTSD symptoms was also calculated, in addition to conditional prevalence rates dependent on trauma type and differential predictors. One-month prevalence rates were as follows: PTSD, 1.5%; CPTSD, 0.5%; and CPTSD variant, 0.7%. For PTSD, the highest conditional prevalence was associated with kidnapping or rape, and the highest CPTSD rates were associated with sexual childhood abuse or rape. PTSD and CPTSD were best differentiated by sexual violence. Combined PTSD and CPTSD (ICD-11) rates were in the range of previously reported prevalences for unified PTSD (Diagnostic and Statistical Manual of Mental Disorders, 4th Edition; ICD-10). Evidence on differential predictors of PTSD and CPTSD is still preliminary.

  19. Scholars' open debate paper on the World Health Organization ICD-11 Gaming Disorder proposal.

    PubMed

    Aarseth, Espen; Bean, Anthony M; Boonen, Huub; Colder Carras, Michelle; Coulson, Mark; Das, Dimitri; Deleuze, Jory; Dunkels, Elza; Edman, Johan; Ferguson, Christopher J; Haagsma, Maria C; Helmersson Bergmark, Karin; Hussain, Zaheer; Jansz, Jeroen; Kardefelt-Winther, Daniel; Kutner, Lawrence; Markey, Patrick; Nielsen, Rune Kristian Lundedal; Prause, Nicole; Przybylski, Andrew; Quandt, Thorsten; Schimmenti, Adriano; Starcevic, Vladan; Stutman, Gabrielle; Van Looy, Jan; Van Rooij, Antonius J

    2017-09-01

    Concerns about problematic gaming behaviors deserve our full attention. However, we claim that it is far from clear that these problems can or should be attributed to a new disorder. The empirical basis for a Gaming Disorder proposal, such as in the new ICD-11, suffers from fundamental issues. Our main concerns are the low quality of the research base, the fact that the current operationalization leans too heavily on substance use and gambling criteria, and the lack of consensus on symptomatology and assessment of problematic gaming. The act of formalizing this disorder, even as a proposal, has negative medical, scientific, public-health, societal, and human rights fallout that should be considered. Of particular concern are moral panics around the harm of video gaming. They might result in premature application of diagnosis in the medical community and the treatment of abundant false-positive cases, especially for children and adolescents. Second, research will be locked into a confirmatory approach, rather than an exploration of the boundaries of normal versus pathological. Third, the healthy majority of gamers will be affected negatively. We expect that the premature inclusion of Gaming Disorder as a diagnosis in ICD-11 will cause significant stigma to the millions of children who play video games as a part of a normal, healthy life. At this point, suggesting formal diagnoses and categories is premature: the ICD-11 proposal for Gaming Disorder should be removed to avoid a waste of public health resources as well as to avoid causing harm to healthy video gamers around the world.

  20. Scholars’ open debate paper on the World Health Organization ICD-11 Gaming Disorder proposal

    PubMed Central

    Aarseth, Espen; Bean, Anthony M.; Boonen, Huub; Colder Carras, Michelle; Coulson, Mark; Das, Dimitri; Deleuze, Jory; Dunkels, Elza; Edman, Johan; Ferguson, Christopher J.; Haagsma, Maria C.; Helmersson Bergmark, Karin; Hussain, Zaheer; Jansz, Jeroen; Kardefelt-Winther, Daniel; Kutner, Lawrence; Markey, Patrick; Nielsen, Rune Kristian Lundedal; Prause, Nicole; Przybylski, Andrew; Quandt, Thorsten; Schimmenti, Adriano; Starcevic, Vladan; Stutman, Gabrielle; Van Looy, Jan; Van Rooij, Antonius J.

    2017-01-01

    Concerns about problematic gaming behaviors deserve our full attention. However, we claim that it is far from clear that these problems can or should be attributed to a new disorder. The empirical basis for a Gaming Disorder proposal, such as in the new ICD-11, suffers from fundamental issues. Our main concerns are the low quality of the research base, the fact that the current operationalization leans too heavily on substance use and gambling criteria, and the lack of consensus on symptomatology and assessment of problematic gaming. The act of formalizing this disorder, even as a proposal, has negative medical, scientific, public-health, societal, and human rights fallout that should be considered. Of particular concern are moral panics around the harm of video gaming. They might result in premature application of diagnosis in the medical community and the treatment of abundant false-positive cases, especially for children and adolescents. Second, research will be locked into a confirmatory approach, rather than an exploration of the boundaries of normal versus pathological. Third, the healthy majority of gamers will be affected negatively. We expect that the premature inclusion of Gaming Disorder as a diagnosis in ICD-11 will cause significant stigma to the millions of children who play video games as a part of a normal, healthy life. At this point, suggesting formal diagnoses and categories is premature: the ICD-11 proposal for Gaming Disorder should be removed to avoid a waste of public health resources as well as to avoid causing harm to healthy video gamers around the world. PMID:28033714

  1. Highly efficient visible-light driven photocatalytic hydrogen production from a novel Z-scheme Er3+:YAlO3/Ta2O5-V5+||Fe3+-TiO2/Au coated composite

    NASA Astrophysics Data System (ADS)

    Wang, Guowei; Ma, Xue; Wei, Shengnan; Li, Siyi; Qiao, Jing; Wang, Jun; Song, Youtao

    2018-01-01

    In this work, the preparation of a novel Z-scheme photocatalyst, Er3+:YAlO3/Ta2O5-V5+||Fe3+-TiO2/Au coated composite, for visible-light photocatalytic hydrogen production is reported for the first time. In this photocatalyst, Au nanoparticles as conduction band co-catalyst provide more active sites to enrich electrons. Ta2O5-V5+||Fe3+-TiO2 as composite redox cycle system thoroughly separates the photo-generated electrons and holes. In addition, Er3+:YAlO3 as up-conversion luminescence agent (from visible-light to ultraviolet-light) provides enough ultraviolet-light for satisfying the energy demand of wide band-gap semiconductors (TiO2 and Ta2O5). The photocatalytic hydrogen production can be achieved from methanol as sacrificial agent (electron donor) under visible-light irradiation. The main influence factors such as initial solution pH and molar ratio of TiO2 and Ta2O5 on visible-light photocatalytic hydrogen production activity of Er3+:YAlO3/Ta2O5-V5+||Fe3+-TiO2/Au coated composite are discussed in detail. The results show that the Er3+:YAlO3/Ta2O5-V5+||Fe3+-TiO2/Au coated composite with 1.0:0.5 M ratio of TiO2 and Ta2O5 in methanol aqueous solution at pH = 6.50 displays the highest photocatalytic hydrogen production activity. Furthermore, a high level of photocatalytic activity can be still maintained within three cycles under the same conditions. It implies that the prepared Z-scheme Er3+:YAlO3/Ta2O5-V5+||Fe3+-TiO2/Au coated composite may be a promising photocatalyst utilizing solar energy for hydrogen production.

  2. Development of Al2O3 fiber-reinforced Al2O3-based ceramics.

    PubMed

    Tanimoto, Yasuhiro; Nemoto, Kimiya

    2004-09-01

    The purpose of this study was to use a tape casting technique to develop an Al2O3 fiber-reinforced Al2O3-based ceramic material (Al2O3-fiber/Al2O3 composite) into a new type of dental ceramic. The Al2O3-based ceramic used a matrix consisting of 60 wt% Al2O3 powder and 40 wt% SiO2-B2O3 powder. The prepreg sheets of Al2O3-fiber/Al2O3 composite (in which uniaxially aligned Al2O3 fibers were infiltrated with the Al2O3-based matrix) were fabricated continuously using tape casting technique with a doctor blade system. Multilayer preforms of Al2O3-fiber/Al2O3 composite sheets were then sintered at a maximum temperature of 1000 degrees C under an atmospheric pressure in a furnace. The results showed that the shrinkage and bending properties of Al2O3-fiber/Al2O3 composite exceeded those of unreinforced Al2O3--hence demonstrating the positive effects of fiber reinforcement. In conclusion, the tape casting technique has been utilized to successfully develop a new type of dental ceramic material.

  3. High thermal stability of La 2O 3 and CeO 2-stabilized tetragonal ZrO 2

    DOE PAGES

    Wang, Shichao; Xie, Hong; Lin, Yuyuan; ...

    2016-02-15

    Catalyst support materials of tetragonal ZrO 2, stabilized by either La 2O 3 (La 2O 3-ZrO 2) or CeO 2 (CeO 2-ZrO 2), were synthesized under hydrothermal conditions at 200 °C with NH 4OH or tetramethylammonium hydroxide as the mineralizer. From In Situ synchrotron powder X-ray diffraction and small-angle X-ray scattering measurements, the calcined La 2O 3-ZrO 2 and CeO 2-ZrO 2 supports were nonporous nanocrystallites that exhibited rectangular shapes with thermal stability up to 1000 °C in air. These supports had an average size of ~10 nm and a surface area of 59-97 m 2/g. The catalysts Pt/La 2Omore » 3-ZrO 2 and Pt/CeO 2-ZrO 2 were prepared by using atomic layer deposition with varying Pt loadings from 6.3-12.4 wt %. Mono-dispersed Pt nanoparticles of ~3 nm were obtained for these catalysts. As a result, the incorporation of La 2O 3 and CeO 2 into the t-ZrO 2 structure did not affect the nature of the active sites for the Pt/ZrO 2 catalysts for the water-gas-shift (WGS) reaction.« less

  4. Density functional theory study of acetaldehyde hydrodeoxygenation on MoO3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mei, Donghai; Karim, Ayman M.; Wang, Yong

    2011-04-06

    Periodic spin-polarized density functional theory calculations were performed to investigate acetaldehyde (CH3CHO) hydrodeoxygenation on the reduced molybdenum trioxide (MoO3) surface. The perfect O-terminated α-MoO3(010) surface is reduced to generate an oxygen defect site in the presence of H2. H2 dissociatively adsorbs at the surface oxygen sites forming two surface hydroxyls, which can recombine into a water molecule weakly bound at the Mo site. A terminal oxygen (Ot) defect site thus forms after water desorption. CH3CHO adsorbs at the O-deficient Mo site via either the sole O-Mo bond or the O-Mo and the C-O double bonds. The possible reaction pathways ofmore » the adsorbed CH3CHO with these two configurations were thoroughly examined using the dimer searching method. Our results show that the ideal deoxygenation of CH3CHO leading to ethylene (C2H4) on the reduced MoO3(010) surface is feasible. The adsorbed CH3CHO first dehydrogenate into CH2CHO by reacting with a neighboring terminal Ot. The hydroxyl (OtH) then hydrogenates CH2CHO into CH2CH2O to complete the hydrogen transfer cycle with an activation barrier of 1.39 eV. The direct hydrogen transfer from CH3CHO to CH2CH2O is unlikely due to the high barrier of 2.00 eV. The produced CH2CH2O readily decomposes into C2H4 that directly releases to the gas phase, and regenerates the Ot atom on the Mo site. As a result, the reduced MoO3(010) surface is reoxidized to the perfect MoO3(010) surface after CH3CHO deoxygenation. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.« less

  5. Interhemispheric differences in polar stratospheric HNO3, H2O, ClO, and O3

    NASA Technical Reports Server (NTRS)

    Santee, M. L.; Read, W. G.; Waters, J. W.; Froidevaux, L.; Manney, G. L.; Flower, D. A.; Jarnot, R. F.; Harwood, R. S.; Peckham, G. E.

    1995-01-01

    Simultaneous global measurements of nitric acid (HNO3), water (H2O), chlorine monoxide (ClO), and ozone (O3) in the stratosphere have been obtained over complete annual cycles in both hemispheres by the Microwave Limb Sounder on the Upper Atmosphere Research Satellite. A sizeable decrease in gas-phase HNO3 was evident in the lower stratospheric vortex over Antarctica by early June 1992, followed by a significant reduction in gas-phase H2O after mid-July. By mid-August, near the time of peak ClO, abundances of gas-phase HNO3 and H2O were extremely low. The concentrations of HNO3 and H2O over Antarctica remained depressed into November, well after temperatures in the lower stratosphere had risen above the evaporation threshold for polar stratospheric clouds, implying that denitrification and dehydration had occurred. No large decreases in either gas-phase HNO3 or H2O were observed in the 1992-1993 Arctic winter vortex. Although ClO was enhanced over the Arctic as it was over the Antarctic, Arctic O3 depletion was substantially smaller than that over Antarctica. A major factor currently limiting the formation of an Arctic ozone 'hole' is the lack of denitrification in the northern polar vortex, but future cooling of the lower stratosphere could lead to more intense denitrification and consequently larger losses of Arctic ozone.

  6. Methanesulfonates of high-valent metals: syntheses and structural features of MoO2(CH3SO3)2, UO2(CH3SO3)2, ReO3(CH3SO3), VO(CH3SO3)2, and V2O3(CH3SO3)4 and their thermal decomposition under N2 and O2 atmosphere.

    PubMed

    Betke, Ulf; Neuschulz, Kai; Wickleder, Mathias S

    2011-11-04

    Oxide methanesulfonates of Mo, U, Re, and V have been prepared by reaction of MoO(3), UO(2)(CH(3)COO)(2)·2H(2)O, Re(2)O(7)(H(2)O)(2), and V(2)O(5) with CH(3)SO(3)H or mixtures thereof with its anhydride. These compounds are the first examples of solvent-free oxide methanesulfonates of these elements. MoO(2)(CH(3)SO(3))(2) (Pbca, a=1487.05(4), b=752.55(2), c=1549.61(5) pm, V=1.73414(9) nm(3), Z=8) contains [MoO(2)] moieties connected by [CH(3)SO(3)] ions to form layers parallel to (100). UO(2)(CH(3)SO(3))(2) (P2(1)/c, a=1320.4(1), b=1014.41(6), c=1533.7(1) pm, β=112.80(1)°, V=1.8937(3) nm(3), Z=8) consists of linear UO(2)(2+) ions coordinated by five [CH(3)SO(3)] ions, forming a layer structure. VO(CH(3)SO(3))(2) (P2(1)/c, a=1136.5(1), b=869.87(7), c=915.5(1) pm, β=113.66(1)°, V=0.8290(2) nm(3), Z=4) contains [VO] units connected by methanesulfonate anions to form corrugated layers parallel to (100). In ReO(3)(CH(3)SO(3)) (P1, a=574.0(1), b=1279.6(3), c=1641.9(3) pm, α=102.08(2), β=96.11(2), γ=99.04(2)°, V=1.1523(4) nm(3), Z=8) a chain structure exhibiting infinite O-[ReO(2)]-O-[ReO(2)]-O chains is formed. Each [ReO(2)]-O-[ReO(2)] unit is coordinated by two bidentate [CH(3)SO(3)] ions. V(2)O(3)(CH(3)SO(3))(4) (I2/a, a=1645.2(3), b=583.1(1), c=1670.2(3) pm, β=102.58(3), V=1.5637(5) pm(3), Z=4) adopts a chain structure, too, but contains discrete [VO]-O-[VO] moieties, each coordinated by two bidentate [CH(3)SO(3)] ligands. Additional methanesulfonate ions connect the [V(2)O(3)] groups along [001]. Thermal decomposition of the compounds was monitored under N(2) and O(2) atmosphere by thermogravimetric/differential thermal analysis and XRD measurements. Under N(2) the decomposition proceeds with reduction of the metal leading to the oxides MoO(2), U(3)O(7), V(4)O(7), and VO(2); for MoO(2)(CH(3)SO(3))(2), a small amount of MoS(2) is formed. If the thermal decomposition is carried out in a atmosphere of O(2) the oxides MoO(3) and V(2)O(5) are formed. Copyright

  7. 77 FR 8877 - ICD-9-CM Coordination and Maintenance (C&M) Committee Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    ... Coordination and Maintenance (C&M) Committee Meeting National Center for Health Statistics (NCHS... Coordination and Maintenance (C&M) Committee meeting. Time and Date: 9 a.m.-5:30 p.m., March 5, 2012. Place... entering the building. Attendees who wish to attend the ICD- 9-CM C&M meeting on March 5, 2012, must submit...

  8. Nonstoichiometry of Epitaxial FeTiO(3+delta) Films

    DTIC Science & Technology

    2003-01-01

    nonstoichiometry of the FeTiO3 +8 films was probably produced by cation vacancies and disarrangement of Fe3+ and Ti4 ions, which randomly occupied both interstitial...and substitutional sites of the FeTiO 3 related structure. INTRODUCTION Solid solutions of ot-Fe20 3- FeTiO3 (hematite-ilmenite) series are known to...tried to confirm preparation conditions of stoichiometric FeTiO 3 films. According to a literature on bulk crystal growth of FeTiO3 [5], very low oxygen

  9. DSM-IV diagnosis in depressed primary care patients with previous psychiatric ICD-10 bipolar disorder.

    PubMed

    Angst, Jules; Hantouche, Elie; Caci, Hervé; Gaillard, Raphael; Lancrenon, Sylvie; Azorin, Jean-Michel

    2014-01-01

    In the past 20 years, much evidence has accumulated against the overly restrictive diagnostic concepts of hypomania in DSM-IV and DSM-IV-TR. We tested DSM-IV-TR and a broader modified version (DSM-IV-TRm) for their ability to detect bipolarity in patients who had been treated for bipolar disorders (BD) in psychiatric settings, and who now consulted general practitioners (GPs) for new major depressive episodes (MDE). Bipolact II was an observational, single-visit survey involving 390 adult patients attending primary care for MDE (DSM-IV-TR criteria) in 201 GP offices in France. The participating GPs (53.3 ± 6.5 years old, 80.1% male) were trained by the Bipolact Educational Program, and were familiar with the medical care of depressive patients. Of the 390 patients with MDE, 129 (33.1%) were previously known as bipolar patients (ICD-10 criteria). Most of the latter bipolar patients (89.7%) had previously been treated with antidepressants. Only 9.3% of them met DMS-IV-TR criteria for BD. Conversely, 79.1% of the 129 bipolar patients met DMS-IV-TRm criteria for BD and showed strong associations with impulse control disorders and manic/hypomanic switches during antidepressant treatment. Limited training of participating GPs, recall bias of patients, and the study not being representative for untreated bipolar patients. Very few ICD-10 bipolar patients consulting French GPs for MDE met DSM-IV-TR criteria for bipolar diagnosis, which suggests that DSM-IV-TR criteria are insufficient and too restrictive for the diagnosis of BD. DSM-IV-TRm was more sensitive, but 20% of bipolar patients were undetected. © 2013 Elsevier B.V. All rights reserved.

  10. Interfacial Ferromagnetism in LaNiO3/CaMnO3 Superlattices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grutter, Alexander J.; Yang, Hao; Kirby, B. J.

    2013-08-01

    We observe interfacial ferromagnetism in superlattices of the paramagnetic metal LaNiO3 and the antiferromagnetic insulator CaMnO3. LaNiO3 exhibits a thickness dependent metal-insulator transition and we find the emergence of ferromagnetism to be coincident with the conducting state of LaNiO3. That is, only superlattices in which the LaNiO3 layers are metallic exhibit ferromagnetism. Using several magnetic probes, we have determined that the ferromagnetism arises in a single unit cell of CaMnO3 at the interface. Together these results suggest that ferromagnetism can be attributed to a double exchange interaction among Mn ions mediated by the adjacent itinerant metal.

  11. Diagnostic Stability of ICD/DSM First Episode Psychosis Diagnoses: Meta-analysis

    PubMed Central

    Fusar-Poli, Paolo; Cappucciati, Marco; Rutigliano, Grazia; Heslin, Margaret; Stahl, Daniel; Brittenden, Zera; Caverzasi, Edgardo; McGuire, Philip; Carpenter, William T.

    2016-01-01

    Background: Validity of current International Classification of Disease/Diagnostic and Statistical Manual of Mental Disorders (ICD/DSM) first episode psychosis diagnoses is essential in clinical practice, research, training and public health. Method: We provide a meta-analytical estimate of prospective diagnostic stability and instability in ICD-10 or DSM-IV first episode diagnoses of functional psychoses. Independent extraction by multiple observers. Random effect meta-analysis conducted with the “metaprop,” “metaninf,” “metafunnel,” “metabias,” and “metareg” packages of STATA13.1. Moderators were tested with meta-regression analyses. Heterogeneity was assessed with the I 2 index. Sensitivity analyses tested robustness of results. Publication biases were assessed with funnel plots and Egger’s test. Findings: 42 studies and 45 samples were included, for a total of 14 484 first episode patients and an average follow-up of 4.5 years. Prospective diagnostic stability ranked: schizophrenia 0.90 (95% CI 0.85–0.95), affective spectrum psychoses 0.84 (95% CI 0.79–0.89), schizoaffective disorder 0.72 (95% CI 0.61–0.73), substance-induced psychotic disorder 0.66 (95% CI 0.51–0.81), delusional disorder 0.59 (95% CI 0.47–0.71), acute and transient psychotic disorder/brief psychotic disorder 0.56 (95% CI 0.62–0.60), psychosis not otherwise specified 0.36 (95% CI 0.27–0.45, schizophreniform disorder 0.29 (95% CI 0.22–0.38). Diagnostic stability within schizophrenia spectrum psychoses was 0.93 (95% CI 0.89–0.97); changes to affective spectrum psychoses were 0.05 (95% CI 0.01–0.08). About 0.10 (95% CI 0.05–0.15) of affective spectrum psychoses changed to schizophrenia spectrum psychosis. Across the other psychotic diagnoses there was high diagnostic instability, mostly to schizophrenia. Interpretation: There is meta-analytical evidence for high prospective diagnostic stability in schizophrenia spectrum and affective spectrum psychoses

  12. On the road to DSM-V and ICD-11.

    PubMed

    Kupfer, David J; Regier, Darrel A; Kuhl, Emily A

    2008-11-01

    Development of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) has been ongoing since 1994, though official release will not occur for another 4 years. Potential revisions are being derived from multiple sources, including building on perceived limitations of DSM-IV; broad-based literature reviews; secondary and primary data analyses; and discussions between global members of the mental health community. The current focus on aligning DSM with the International Classification of Diseases-11 (ICD-11) speaks to the importance of creating a unified text that embraces cross-cutting issues of diagnostics, such as developmental, age-related, and cultural phenomena. International discourse is vital to this process and has been fostered by a National Institutes of Health-sponsored conference series on diagnosis-specific topics. From this series, the DSM-V Task Force developed the following set of revision principals to guide the efforts of the DSM-V Work Groups: grounding recommendations in empirical evidence; maintaining continuity with previous editions of DSM; removing a priori limitations on the amount of changes DSM-V may incur; and maintaining DSM's status as a living document. With work group formation complete, members are currently carrying out the research and revision recommendations proposed during the conference series. Ongoing activities include adding specialized advisors to each work group; completing literature reviews and planning data analyses; and forming study groups to discuss integration of cross-cutting issues (e.g., developmental lifespan factors; formation of diagnostic spectra). The road to DSM-V and ICD-11 has been challenging, but members continue to work diligently in their goal of constructing the most harmonious, scientifically sound, and clinically relevant DSM to date.

  13. SmNiO3/NdNiO3 thin film multilayers

    NASA Astrophysics Data System (ADS)

    Girardot, C.; Pignard, S.; Weiss, F.; Kreisel, J.

    2011-06-01

    Rare earth nickelates RENiO3 (RE =rare earth), which attract interest due to their sharp metal-insulator phase transition, are instable in bulk form due to the necessity of an important oxygen pressure to stabilize Ni in its 3+ state of oxidation. Here, we report the stabilization of RE nickelates in [(SmNiO3)t/(NdNiO3)t]n thin film multilayers, t being the thickness of layers alternated n times. Both bilayers and multilayers have been deposited by metal-organic chemical vapor deposition. The multilayer structure and the presence of the metastable phases SmNiO3 and NdNiO3 are evidenced from by x-ray and Raman scattering. Electric measurements of a bilayer structure further support the structural quality of the embedded RE nickelate layers.

  14. OPTICAL AND SPECTROSCOPIC STUDIES OF Fe2O3-Bi2O3-B2O3:V2O5 GLASSES

    NASA Astrophysics Data System (ADS)

    Sanjay; Kishore, N.; Agarwal, A.; Dahiya, S.; Pal, Inder; Kumar, Navin

    2013-11-01

    The glasses of compositions xFe2O3ṡ (40 - x)Bi2O3ṡ60B2O3ṡ2V2O5 have been prepared by the standard melt-quenching technique. Amorphous nature of these samples is ascertained by XRD patterns. The presence of BO3 and BO4 units is identified by IR spectra of glass samples. The absorption edge (λcut-off) shifts toward longer wavelengths with an increase in Fe2O3 content in the glass matrix. The values of optical band gap energy for indirect allowed and forbidden transitions have been determined and it is found to decrease with increase in transition metal ions. The Urbach's energy is used to characterize the degree of disorder in amorphous solids.

  15. Impact of new X-ray technology on patient dose in pacemaker and implantable cardioverter defibrillator (ICD) implantations.

    PubMed

    van Dijk, Joris D; Ottervanger, Jan Paul; Delnoy, Peter Paul H M; Lagerweij, Martine C M; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L

    2017-01-01

    New X-ray technology providing new image processing techniques may reduce radiation exposure. The aim of this study was to quantify this radiation exposure reduction for patients during pacemaker and implantable cardioverter defibrillator (ICD) implantation. In this retrospective study, 1185 consecutive patients who had undergone de novo pacemaker or ICD implantation during a 2-year period were included. All implantations in the first year were performed using the reference technology (Allura Xper), whereas in the second year, the new X-ray technology (AlluraClarity) was used. Radiation exposure, expressed as the dose area product (DAP), was compared between the two time periods to determine the radiation exposure reduction for pacemaker and ICD implantations without cardiac resynchronization therapy (CRT) and with CRT. Procedure duration and contrast volume were used as measures to compare complexity and image quality. The study population consisted of 591 patients who had undergone an implantation using the reference technology, and 594 patients with the new X-ray technology. The two groups did not differ in age, gender, or body mass index. The DAP decreased with 69 % from 16.4 ± 18.5 to 5.2 ± 6.6 Gy cm 2 for the non-CRT implantations (p < 0.001). The DAP decreased with 75 % from 72.1 ± 60.0 to 17.8 ± 17.4 Gy cm 2 for the CRT implantations (p < 0.001). Nevertheless, procedure duration and contrast volume did not differ when using the new technology (p = 0.09 and p = 0.20, respectively). Introduction of new X-ray technology resulted in a radiation exposure reduction of more than 69 % for patients during pacemaker and ICD implantation while image quality was unaffected.

  16. 17O excess transfer during the NO2 + O3 → NO3 + O2 reaction.

    PubMed

    Berhanu, Tesfaye Ayalneh; Savarino, Joël; Bhattacharya, S K; Vicars, Willliam C

    2012-01-28

    The ozone molecule possesses a unique and distinctive (17)O excess (Δ(17)O), which can be transferred to some of the atmospheric molecules via oxidation. This isotopic signal can be used to trace oxidation reactions in the atmosphere. However, such an approach depends on a robust and quantitative understanding of the oxygen transfer mechanism, which is currently lacking for the gas-phase NO(2) + O(3) reaction, an important step in the nocturnal production of atmospheric nitrate. In the present study, the transfer of Δ(17)O from ozone to nitrate radical (NO(3)) during the gas-phase NO(2) + O(3) → NO(3) + O(2) reaction was investigated in a series of laboratory experiments. The isotopic composition (δ(17)O, δ(18)O) of the bulk ozone and the oxygen gas produced in the reaction was determined via isotope ratio mass spectrometry. The Δ(17)O transfer function for the NO(2) + O(3) reaction was determined to be: Δ(17)O(O(3)∗) = (1.23 ± 0.19) × Δ(17)O(O(3))(bulk) + (9.02 ± 0.99). The intramolecular oxygen isotope distribution of ozone was evaluated and results suggest that the excess enrichment resides predominantly on the terminal oxygen atoms of ozone. The results obtained in this study will be useful in the interpretation of high Δ(17)O values measured for atmospheric nitrate, thus leading to a better understanding of the natural cycling of atmospheric reactive nitrogen. © 2012 American Institute of Physics

  17. The Molybdenum(V) and Tungsten(VI) Oxoazides [MoO(N3 )3 ], [MoO(N3 )3 ⋅2 CH3 CN], [(bipy)MoO(N3 )3 ], [MoO(N3 )5 ](2-) , [WO(N3 )4 ], and [WO(N3 )4 ⋅CH3 CN].

    PubMed

    Haiges, Ralf; Skotnitzki, Juri; Fang, Zongtang; Dixon, David A; Christe, Karl O

    2015-12-14

    A series of novel molybdenum(V) and tungsten(VI) oxoazides was prepared starting from [MOF4 ] (M=Mo, W) and Me3 SiN3 . While [WO(N3 )4 ] was formed through fluoride-azide exchange in the reaction of Me3 SiN3 with WOF4 in SO2 solution, the reaction with MoOF4 resulted in a reduction of Mo(VI) to Mo(V) and formation of [MoO(N3 )3 ]. Carried out in acetonitrile solution, these reactions resulted in the isolation of the corresponding adducts [MoO(N3 )3 ⋅2 CH3 CN] and [WO(N3 )4 ⋅CH3 CN]. Subsequent reactions of [MoO(N3 )3 ] with 2,2'-bipyridine and [PPh4 ][N3 ] resulted in the formation and isolation of [(bipy)MoO(N3 )3 ] and [PPh4 ]2 [MoO(N3 )5 ], respectively. Most molybdenum(V) and tungsten(VI) oxoazides were fully characterized by their vibrational spectra, impact, friction and thermal sensitivity data and, in the case of [WO(N3 )4 ⋅CH3 CN], [(bipy)MoO(N3 )3 ], and [PPh4 ]2 [MoO(N3 )5 ], by their X-ray crystal structures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Confinement- and strain-induced enhancement of thermoelectric properties in LaNiO3/LaAlO3(001 ) superlattices

    NASA Astrophysics Data System (ADS)

    Geisler, Benjamin; Pentcheva, Rossitza

    2018-05-01

    By combining ab initio simulations including an on-site Coulomb repulsion term and Boltzmann theory, we explore the thermoelectric properties of (LaNiO3)n /(LaAlO3)n (001) superlattices (n =1 ,3 ) and identify a strong dependence on confinement, spacer thickness, and epitaxial strain. While the system with n =3 shows modest values of the Seebeck coefficient and power factor, the simultaneous reduction of the LaNiO3 region and the LaAlO3 spacer thickness to single layers results in a strong enhancement, in particular of the in-plane values. This effect can be further tuned by using epitaxial strain as a control parameter: Under tensile strain corresponding to the lateral lattice constant of SrTiO3 we predict in- and cross-plane Seebeck coefficients of ±600 μ V /K and an in-plane power factor of 11 μ W /K2cm for an estimated relaxation time of τ =4 fs around room temperature. These values are comparable to some of the best performing oxide systems such as La-doped SrTiO3 or layered cobaltates and are associated with the opening of a small gap (0.29 eV) induced by the concomitant effect of octahedral tilting and Ni-site disproportionation. This establishes oxide superlattices at the verge of a metal-to-insulator transition driven by confinement and strain as promising candidates for thermoelectric materials.

  19. T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

    NASA Technical Reports Server (NTRS)

    Hohnloser, S. H.; Klingenheben, T.; Li, Y. G.; Zabel, M.; Peetermans, J.; Cohen, R. J.

    1998-01-01

    INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular

  20. Gender Incongruence of Childhood: Clinical Utility and Stakeholder Agreement with the World Health Organization’s Proposed ICD-11 Criteria

    PubMed Central

    Beek, Titia F.; Cohen-Kettenis, Peggy T.; Bouman, Walter P.; de Vries, Annelou L. C.; Steensma, Thomas D.; Witcomb, Gemma L.; Arcelus, Jon; Richards, Christina; De Cuypere, Griet; Kreukels, Baudewijntje P. C.

    2017-01-01

    The World Health Organization (WHO) is revising the tenth version of the International Classification of Diseases and Related Health Problems (ICD-10). This includes a reconceptualization of the definition and positioning of Gender Incongruence of Childhood (GIC). This study aimed to: 1) collect the views of transgender individuals and professionals regarding the retention of the diagnosis; 2) see if the proposed GIC criteria were acceptable to transgender individuals and health care providers; 3) compare results between two countries with two different healthcare systems to see if these differences influence opinions regarding the GIC diagnosis; and 4) determine whether healthcare providers from high-income countries feel that the proposed criteria are clinically useful and easy to use. A total of 628 participants were included in the study: 284 from the Netherlands (NL; 45.2%), 8 from Flanders (Belgium; 1.3%), and 336 (53.5%) from the United Kingdom (UK). Most participants were transgender people (or their partners/relatives; TG) (n = 522), 89 participants were healthcare providers (HCPs) and 17 were both HCP and TG individuals. Participants completed an online survey developed for this study. Overall, the majority response from transgender participants (42.9%) was that if the diagnosis would be removed from the mental health chapter it should also be removed from the ICD-11 completely, while 33.6% thought it should remain in the ICD-11. Participants were generally satisfied with other aspects of the proposed ICD-11 GIC diagnosis: most TG participants (58.4%) thought the term Gender Identity Disorder should change, and most thought Gender Incongruence was an improvement (63.0%). Furthermore, most participants (76.1%) did not consider GIC to be a psychiatric disorder and placement in a separate chapter dealing with Gender and Sexual Health (the majority response in the NL and selected by 37.5% of the TG participants overall) or as a Z-code (the majority response

  1. First-principles study of (Ba ,Ca ) TiO3 and Ba (Ti ,Zr ) O3 solid solutions

    NASA Astrophysics Data System (ADS)

    Amoroso, Danila; Cano, Andrés; Ghosez, Philippe

    2018-05-01

    (Ba ,Ca ) TiO3 and Ba (Ti ,Zr ) O3 solid solutions are the building blocks of lead-free piezoelectric materials that attract a renewed interest. We investigate the properties of these systems by means of first-principles calculations, with a focus on the lattice dynamics and the competition between different ferroelectric phases. We first analyze the four parent compounds in order to compare their properties and their different tendency towards ferroelectricity. The core of our study is systematic characterization of the binary systems (Ba ,Ca ) TiO3 and Ba (Ti ,Zr ) O3 within both the virtual crystal approximation and direct supercell calculations. In the case of Ca doping, we find a gradual transformation from B -site to A -site ferroelectricity due to steric effects that largely determines the behavior of the system. In the case of Zr doping, in contrast, the behavior is eventually dominated by cooperative Zr-Ti motions and the local electrostatics. In addition, our comparative study reveals that the specific microscopic physics of these solids sets severe limits to the applicability of the virtual crystal approximation for these systems.

  2. Violet-green excitation for NIR luminescence of Yb3+ ions in Bi2O3-B2O3-SiO2-Ga2O3 glasses.

    PubMed

    Li, Weiwei; Cheng, Jimeng; Zhao, Guoying; Chen, Wei; Hu, Lili; Guzik, Malgorzata; Boulon, Georges

    2014-04-21

    60Bi(2)O(3)-20B(2)O(3)-10SiO(2)-10Ga(2)O(3) glasses doped with 1-9 mol% Yb(2)O(3) were prepared and investigated mainly on their violet-green excitation for the typical NIR emission of Yb(3+), generally excited in the NIR. Two violet excitation bands at 365 nm and 405 nm are related to Yb(2+) and Bi(3+). 465 nm excitation band and 480 nm absorption band in the blue-green are assigned to Bi(0) metal nanoparticles/grains. Yb-content-dependence of the excitation and absorption means that Bi(0) is the reduced product of Bi(3+), but greatly competed by the redox reaction of Yb(2+) ↔ Yb(3+). It is proved that the violet-green excitations result in the NIR emission of Yb(3+). On the energy transfer, the virtual level of Yb(3+)-Yb(3+) as well as Bi(0) dimers probably plays an important role. An effective and controllable way is suggested to achieve nano-optical applications by Bi(0) metal nanoparticles/grains and Yb(3+).

  3. Compositional and gate tuning of the interfacial conductivity in LaAlO3/LaTiO3/SrTiO3 heterostructures

    NASA Astrophysics Data System (ADS)

    Hosoda, Masayuki; Bell, Christopher; Hikita, Yasuyuki; Hwang, Harold Y.

    2013-03-01

    We investigate the effect of LaTiO3 insertion at the interface between LaAlO3 and TiO2 terminated {100} SrTiO3 for a series of LaAlO3 and LaTiO3 thicknesses. A clear increase of the carrier density was observed while the Hall mobility was largely unchanged. In structures with LaAlO3 thickness ˜3 unit cells, close to the critical thickness for conductivity, as little as 0.25 unit cells of LaTiO3 drives an insulator-to-metal transition. These samples show a strong dependence of the conductivity on voltage with electrostatic back-gating, which can be understood in a two-carrier picture, and dominated by the change in carrier density at the interface.

  4. ICD-11 complex PTSD among Israeli male perpetrators of intimate partner violence: Construct validity and risk factors.

    PubMed

    Gilbar, Ohad; Hyland, Philip; Cloitre, Marylene; Dekel, Rachel

    2018-03-01

    The International Classification of Diseases 11th Version (ICD-11) will include Complex Posttraumatic Stress Disorder (CPTSD) as a unique diagnostic entity comprising core PTSD and DSO (disturbances in self-organization) symptoms. The current study had three aims: (1) assessing the validity of CPTSD in a unique population of male perpetrators of intimate partner violence; (2) examining whether exposure to different types of traumatic events would be associated with the two proposed CPTSD factors, namely PTSD or DSO; and (3) assessing the differential association of various sociodemographic and symptom characteristics with each factor. Participants were 234 males drawn randomly from a sample of 2600 men receiving treatment at 66 domestic violence centers in Israel. Data were collected using the International Trauma Questionnaire (ITQ) - Hebrew version. Confirmatory factor analysis supported the factorial validity of ICD-11 CPTSD. Cumulative lifetime trauma and physical childhood neglect were associated with PTSD and DSO, while cumulative childhood violence exposure was associated only with DSO. Anxiety was associated only with DSO; depression more strongly with DSO than PTSD. Religious level contributed only to PTSD; compulsory military service only to DSO. The study supports the distinction between PTSD and DSO in the CPTSD construct and introduces the role of cultural variables. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Controlling n-type doping in MoO 3

    DOE PAGES

    Peelaers, H.; Chabinyc, M. L.; Van de Walle, C. G.

    2017-02-27

    Here, we study the electronic properties of native defects and intentional dopant impurities in MoO 3, a widely used transparent conductor. Using first-principles hybrid functional calculations, we show that electron polarons can be self-trapped, but they can also bind to defects; thus, they play an important role in understanding the properties of doped MoO 3. Our calculations show that oxygen vacancies can cause unintentional n-type doping in MoO 3. Mo vacancies are unlikely to form. Tc and Re impurities on the Mo site and halogens (F, Cl, and Br) on the O site all act as shallow donors but trapmore » electron polarons. Fe, Ru, and Os impurities are amphoteric and will compensate n-type MoO 3. Mn dopants are also amphoteric, and they show interesting magnetic properties. These results support the design of doping approaches that optimally exploit functionality.« less

  6. Pinhole mediated electrical transport across LaTiO3/SrTiO3 and LaAlO3/SrTiO3 oxide hetero-structures

    NASA Astrophysics Data System (ADS)

    Kumar, Pramod; Dogra, Anjana; Toutam, Vijaykumar

    2013-11-01

    Metal-insulator-metal configuration of LaTiO3/SrTiO3 and LaAlO3/SrTiO3 hetero-structures between two dimensional electron gas formed at the interface and different area top electrodes is employed for Conductive Atomic force microscopy (CAFM) imaging, Current-Voltage (I-V), and Capacitance-Voltage (C-V) spectroscopy. Electrode area dependent I-V characteristics are observed for these oxide hetero-structures. With small area electrodes, rectifying I-V characteristics are observed, compared to, both tunneling and leakage current characteristics for large area electrodes. CAFM mapping confirmed the presence of pinholes on both surfaces. Resultant I-V characteristics have a contribution from both tunneling and leakage due to pinholes.

  7. Importance of ICD-10 coding directive change for acute gastroenteritis (unspecified) for rotavirus vaccine impact studies: illustration from a population-based cohort study from Ontario, Canada.

    PubMed

    Wilson, Sarah E; Deeks, Shelley L; Rosella, Laura C

    2015-09-15

    In Ontario, Canada, we conducted an evaluation of rotavirus (RV) vaccine on hospitalizations and Emergency Department (ED) visitations for acute gastroenteritis (AGE). In our original analysis, any one of the International Classification of Disease, Version 10 (ICD-10) codes was used for outcome ascertainment: RV-specific- (A08.0), viral- (A08.3, A08. 4, A08.5), and unspecified infectious- gastroenteritis (A09). Annual age-specific rates per 10,000 population were calculated. The average monthly rate of AGE hospitalization for children under age two increased from 0.82 per 10,000 from January 2003 to March 2009, to 2.35 over the period of April 2009 to March 31, 2013. Similar trends were found for ED consultations and in other age groups. A rise in events corresponding to the A09 code was found when the outcome definition was disaggregated by ICD-10 code. Documentation obtained from the World Health Organization confirmed that a change in directive for the classification of unspecified gastroenteritis occurred with the release of ICD-10 in April 2009. AGE events previously classified under the code K52.9, are now classified under code A09.9. Based on change in the classification of unspecified gastroenteritis we modified our outcome definition to also include unspecified non-infectious-gastroenteritis (K52.9). We recommend other investigators consider using both A09.9 and K52.9 ICD-10 codes for outcome ascertainment in future rotavirus vaccine impact studies to ensure that all unspecified cases of AGE are captured, especially if the study period spans 2009.

  8. AAIDD Proposed Recommendations for "ICD-11" and the Condition Previously Known as Mental Retardation

    ERIC Educational Resources Information Center

    Tasse, Marc J.; Luckasson, Ruth; Nygren, Margaret

    2013-01-01

    The World Health Organization (WHO) is in the process of seeking input from professional stakeholder groups and consumers regarding the draft proposals of the 11th edition of the "International Classification of Diseases" ("ICD-11"). The American Association on Intellectual and Developmental Disabilities (AAIDD) convened a small group of…

  9. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    PubMed

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  10. Electric Properties of Pb(Sb1/2Nb1/2)O3 PbTiO3 PbZrO3 Ceramics

    NASA Astrophysics Data System (ADS)

    Kawamura, Yasushi; Ohuchi, Hiromu

    1994-09-01

    Solid-solution ceramics of ternary system xPb(Sb1/2Nb1/2)O3 yPbTiO3 zPbZrO3 were prepared by the solid-state reaction of powder materials. Ceramic, electric, dielectric and piezoelectric properties and crystal structures of the system were studied. Sintering of the system xPb(Sb1/2Nb1/2)O3 yPbTiO3 zPbZrO3 is much easier than that of each end composition, and well-sintered high-density ceramics were obtained for the compositions near the morphotropic transformation. Piezoelectric ceramics with high relative dielectric constants, high radial coupling coefficient and low resonant resistance were obtained for the composition near the morphotropic transformation. The composition Pb(Sb1/2Nb1/2)0.075Ti0.45Zr0.475O3 showed the highest dielectric constant (ɛr=1690), and the composition Pb(Sb1/2Nb1/2)0.05Ti0.45Zr0.5O3 showed the highest radial coupling coefficient (kp=64%).

  11. Energy transfer mechanism of Sm3+/Eu3+ co-doped 2CaO-B2O3-P2O5 phosphors

    NASA Astrophysics Data System (ADS)

    Prasad, V. Reddy; Damodaraiah, S.; Ratnakaram, Y. C.

    2018-04-01

    Sm3+/Eu3+ co-doped calcium borophosphate phosphors were synthesized by solid state reaction method. 2CaO-B2O3-P2O5: Sm3+/Eu3+ co-doped phosphors were characterized by XRD, SEM, 31P solid state NMR, excitation, photoluminescence (PL) and decay profiles.. XRD profiles showed that the prepared phosphors exhibit a hexagonal phase in crystal structure and SEM results showed that the particles are more irregular morphologies. From 31P NMR spectra of Sm3+/Eu3+ co-doped 2CaO-B2O3-P2O5 phosphors, the chemical shifts located in the positive frequency region indicating the presence of mono-phosphate complexes Q0-(PO43 - ) . Photoluminescence spectra of Sm3+/Eu3+ co-doped 2CaO-B2O3-P2O5 phosphors show enhancement in emission intensity of Eu3+ ion due to co-doping with Sm3+ ions through energy transfer process. The energy level mechanism between Sm3+ and Eu3+ ions has been clearly explained. The energy transfer process has also been evidenced by lifetime decay profiles. These results suggest that the prepared phosphors are potential red luminescent optical materials.

  12. PTSD or not PTSD? Comparing the proposed ICD-11 and the DSM-5 PTSD criteria among young survivors of the 2011 Norway attacks and their parents.

    PubMed

    Hafstad, G S; Thoresen, S; Wentzel-Larsen, T; Maercker, A; Dyb, G

    2017-05-01

    The conceptualization of post-traumatic stress disorder (PTSD) in the upcoming International Classification of Diseases (ICD)-11 differs in many respects from the diagnostic criteria in the Diagnostic and Statistical Manual for Mental Disorders, fifth edition (DSM-5). The consequences of these differences for individuals and for estimation of prevalence rates are largely unknown. This study investigated the concordance of the two diagnostic systems in two separate samples at two separate waves. Young survivors of the 2011 Norway attacks (n = 325) and their parents (n = 451) were interviewed at 4-6 months (wave 1) and 15-18 months (wave 2) after the shooting. PTSD was assessed with the UCLA PTSD Reaction Index for DSM-IV adapted for DSM-5, and a subset was used as diagnostic criteria for ICD-11. In survivors, PTSD prevalence did not differ significantly at any time point, but in parents, the DSM-5 algorithm produced significantly higher prevalence rates than the ICD-11 criteria. The overlap was fair for survivors, but amongst parents a large proportion of individuals met the criteria for only one of the diagnostic systems. No systematic differences were found between ICD-11 and DSM-5 in predictive validity. The proposed ICD-11 criteria and the DSM-5 criteria performed equally well when identifying individuals in distress. Nevertheless, the overlap between those meeting the PTSD diagnosis for both ICD-11 and DSM-5 was disturbingly low, with the ICD-11 criteria identifying fewer people than the DSM-5. This represents a major challenge in identifying individuals suffering from PTSD worldwide, possibly resulting in overtreatment or unmet needs for trauma-specific treatment, depending on the area of the world in which patients are being diagnosed.

  13. SAW propagation characteristics of TeO3/3C-SiC/LiNbO3 layered structure

    NASA Astrophysics Data System (ADS)

    Soni, Namrata D.

    2018-04-01

    Surface acoustic wave (SAW) devices based on Lithium Niobate (LiNbO3) single crystal are advantageous because of its high SAW phase velocity, electromechanical coupling coefficient and cost effectiveness. In the present work a new multi-layered TeO3/3C-SiC/128° Y-X LiNbO3 SAW device has been proposed. SAW propagation properties such as phase velocity, coupling coefficient and temperature coefficient of delay (TCD) of the TeO3/SiC/128° Y-X LiNbO3 multi layered structure is examined using theoretical calculations. It is found that the integration of 0.09λ thick 3C-SiC over layer on 128° Y-X LiNbO3 increases its electromechanical coupling coefficient from 5.3% to 9.77% and SAW velocity from 3800 ms‑1 to 4394 ms‑1. The SiC/128° Y-X LiNbO3 bilayer SAW structure exhibits a high positive TCD value. A temperature stable layered SAW device could be obtained with introduction of 0.007λ TeO3 over layer on SiC/128° Y-X LiNbO3 bilayer structure without sacrificing the efficiency of the device. The proposed TeO3/3C-SiC/128° Y-X LiNbO3 multi-layered SAW structure is found to be cost effective, efficient, temperature stable and suitable for high frequency application in harsh environment.

  14. The effect of Al2O3, CaO, Cr2O3 and MgO on devitrification of silica

    NASA Technical Reports Server (NTRS)

    Zaplatynsky, Isidor

    1988-01-01

    The effect of doping on devitrification of vitreous silica was studied at 1100, 1200, and 1300 C. Dispersion of dopants on a molecular scale was accomplished via a sol-gel technique. All dopants accelerated the devitrification of silica but to different degrees. The most active was CaO followed by MgO, Al2O3, and Cr2O3. Pure silica and silica containing Cr2O3 and Al2O3 devitrified to alpha-cristobalite only, whereas silica doped with CaO and MgO produced alpha-quartz and alpha-cristobalite. It appears that prolonged heat treatment would cause alpha-quartz to transform to alpha-cristobalite.

  15. Novel ZrO2 based ceramics stabilized by Fe2O3, SiO2 and Y2O3

    NASA Astrophysics Data System (ADS)

    Rada, S.; Culea, E.; Rada, M.

    2018-03-01

    Samples in the 5Fe2O3·10SiO2·xY2O3·(85-x)ZrO2 composition where x = 5, 10 and 15 mol% Y2O3 were synthesized and investigated by XRD, SEM, density measurements, FTIR, UV-Vis, EPR and PL spectroscopies. X-ray diffraction patterns confirm the presence of the tetragonal and cubic ZrO2 crystalline phases in all samples. The IR data show the overlaps of absorption bands assigned to Zrsbnd Osbnd Zr and Sisbnd Osbnd linkages in samples. UV-Vis and PL data indicate higher concentrations of intrinsic defects by doping with Y2O3 concentrations. The EPR spectra are characterized by two resonance lines situated at about g ∼ 4.3 and g ∼ 2 for lower Y2O3 contents.

  16. Magnetic interactions in BiFe0.5Mn0.5O3 films and BiFeO3/BiMnO3 superlattices

    NASA Astrophysics Data System (ADS)

    Xu, Qingyu; Sheng, Yan; Khalid, M.; Cao, Yanqiang; Wang, Yutian; Qiu, Xiangbiao; Zhang, Wen; He, Maocheng; Wang, Shuangbao; Zhou, Shengqiang; Li, Qi; Wu, Di; Zhai, Ya; Liu, Wenqing; Wang, Peng; Xu, Y. B.; Du, Jun

    2015-03-01

    The clear understanding of exchange interactions between magnetic ions in substituted BiFeO3 is the prerequisite for the comprehensive studies on magnetic properties. BiFe0.5Mn0.5O3 films and BiFeO3/BiMnO3 superlattices have been fabricated by pulsed laser deposition on (001) SrTiO3 substrates. Using piezoresponse force microscopy (PFM), the ferroelectricity at room temperature has been inferred from the observation of PFM hysteresis loops and electrical writing of ferroelectric domains for both samples. Spin glass behavior has been observed in both samples by temperature dependent magnetization curves and decay of thermo-remnant magnetization with time. The magnetic ordering has been studied by X-ray magnetic circular dichroism measurements, and Fe-O-Mn interaction has been confirmed to be antiferromagnetic (AF). The observed spin glass in BiFe0.5Mn0.5O3 films has been attributed to cluster spin glass due to Mn-rich ferromagnetic (FM) clusters in AF matrix, while spin glass in BiFeO3/BiMnO3 superlattices is due to competition between AF Fe-O-Fe, AF Fe-O-Mn and FM Mn-O-Mn interactions in the well ordered square lattice with two Fe ions in BiFeO3 layer and two Mn ions in BiMnO3 layer at interfaces.

  17. Photoemission from buried interfaces in SrTiO3/LaTiO3 superlattices.

    PubMed

    Takizawa, M; Wadati, H; Tanaka, K; Hashimoto, M; Yoshida, T; Fujimori, A; Chikamatsu, A; Kumigashira, H; Oshima, M; Shibuya, K; Mihara, T; Ohnishi, T; Lippmaa, M; Kawasaki, M; Koinuma, H; Okamoto, S; Millis, A J

    2006-08-04

    We have measured photoemission spectra of SrTiO3/LaTiO3 superlattices with a topmost SrTiO3 layer of variable thickness. A finite coherent spectral weight with a clear Fermi cutoff was observed at chemically abrupt SrTiO3/LaTiO3 interfaces, indicating that an "electronic reconstruction" occurs at the interface between the Mott insulator LaTiO3 and the band insulator SrTiO3. For SrTiO3/LaTiO3 interfaces annealed at high temperatures (approximately 1000 degrees C), which leads to Sr/La atomic interdiffusion and hence to the formation of La(1-x)Sr(x)TiO3-like material, the intensity of the incoherent part was found to be dramatically reduced whereas the coherent part with a sharp Fermi cutoff was enhanced due to the spread of charge. These important experimental features are well reproduced by layer dynamical-mean-field-theory calculation.

  18. Crystal structure of bis-(μ-3-nitro-benzoato)-κ3O,O':O3O:O,O'-bis-[bis-(3-cyano-pyridine-κN1)(3-nitro-benzoato-κ2O,O')cadmium].

    PubMed

    Hökelek, Tuncer; Akduran, Nurcan; Özen, Azer; Uğurlu, Güventürk; Necefoğlu, Hacali

    2017-03-01

    The asymmetric unit of the title compound, [Cd 2 (C 7 H 4 NO 4 ) 4 (C 6 H 4 N 2 ) 4 ], contains one Cd II atom, two 3-nitro-benzoate (NB) anions and two 3-cyano-pyridine (CPy) ligands. The two CPy ligands act as monodentate N(pyridine)-bonding ligands, while the two NB anions act as bidentate ligands through the carboxyl-ate O atoms. The centrosymmetric dinuclear complex is generated by application of inversion symmetry, whereby the Cd II atoms are bridged by the carboxyl-ate O atoms of two symmetry-related NB anions, thus completing the distorted N 2 O 5 penta-gonal-bipyramidal coordination sphere of each Cd II atom. The benzene and pyridine rings are oriented at dihedral angles of 10.02 (7) and 5.76 (9)°, respectively. In the crystal, C-H⋯N hydrogen bonds link the mol-ecules, enclosing R 2 2 (26) ring motifs, in which they are further linked via C-H⋯O hydrogen bonds, resulting in a three-dimensional network. In addition, π-π stacking inter-actions between parallel benzene rings and between parallel pyridine rings of adjacent mol-ecules [shortest centroid-to-centroid distances = 3.885 (1) and 3.712 (1) Å, respectively], as well as a weak C-H⋯π inter-action, may further stabilize the crystal structure.

  19. Insight into Ca-Substitution Effects on O3-Type NaNi1/3 Fe1/3 Mn1/3 O2 Cathode Materials for Sodium-Ion Batteries Application.

    PubMed

    Sun, Liqi; Xie, Yingying; Liao, Xiao-Zhen; Wang, Hong; Tan, Guoqiang; Chen, Zonghai; Ren, Yang; Gim, Jihyeon; Tang, Wan; He, Yu-Shi; Amine, Khalil; Ma, Zi-Feng

    2018-04-18

    O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 (NaNFM) is well investigated as a promising cathode material for sodium-ion batteries (SIBs), but the cycling stability of NaNFM still needs to be improved by using novel electrolytes or optimizing their structure with the substitution of different elements sites. To enlarge the alkali-layer distance inside the layer structure of NaNFM may benefit Na + diffusion. Herein, the effect of Ca-substitution is reported in Na sites on the structural and electrochemical properties of Na 1- x Ca x /2 NFM (x = 0, 0.05, 0.1). X-ray diffraction (XRD) patterns of the prepared Na 1- x Ca x /2 NFM samples show single α-NaFeO 2 type phase with slightly increased alkali-layer distance as Ca content increases. The cycling stabilities of Ca-substituted samples are remarkably improved. The Na 0.9 Ca 0.05 Ni 1/3 Fe 1/3 Mn 1/3 O 2 (Na 0.9 Ca 0.05 NFM) cathode delivers a capacity of 116.3 mAh g -1 with capacity retention of 92% after 200 cycles at 1C rate. In operando XRD indicates a reversible structural evolution through an O3-P3-P3-O3 sequence of Na 0.9 Ca 0.05 NFM cathode during cycling. Compared to NaNMF, the Na 0.9 Ca 0.05 NFM cathode shows a wider voltage range in pure P3 phase state during the charge/discharge process and exhibits better structure recoverability after cycling. The superior cycling stability of Na 0.9 Ca 0.05 NFM makes it a promising material for practical applications in sodium-ion batteries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. ICD-10 codes used to identify adverse drug events in administrative data: a systematic review.

    PubMed

    Hohl, Corinne M; Karpov, Andrei; Reddekopp, Lisa; Doyle-Waters, Mimi; Stausberg, Jürgen

    2014-01-01

    Adverse drug events, the unintended and harmful effects of medications, are important outcome measures in health services research. Yet no universally accepted set of International Classification of Diseases (ICD) revision 10 codes or coding algorithms exists to ensure their consistent identification in administrative data. Our objective was to synthesize a comprehensive set of ICD-10 codes used to identify adverse drug events. We developed a systematic search strategy and applied it to five electronic reference databases. We searched relevant medical journals, conference proceedings, electronic grey literature and bibliographies of relevant studies, and contacted content experts for unpublished studies. One author reviewed the titles and abstracts for inclusion and exclusion criteria. Two authors reviewed eligible full-text articles and abstracted data in duplicate. Data were synthesized in a qualitative manner. Of 4241 titles identified, 41 were included. We found a total of 827 ICD-10 codes that have been used in the medical literature to identify adverse drug events. The median number of codes used to search for adverse drug events was 190 (IQR 156-289) with a large degree of variability between studies in the numbers and types of codes used. Authors commonly used external injury (Y40.0-59.9) and disease manifestation codes. Only two papers reported on the sensitivity of their code set. Substantial variability exists in the methods used to identify adverse drug events in administrative data. Our work may serve as a point of reference for future research and consensus building in this area.

  1. ICD-10 codes used to identify adverse drug events in administrative data: a systematic review

    PubMed Central

    Hohl, Corinne M; Karpov, Andrei; Reddekopp, Lisa; Stausberg, Jürgen

    2014-01-01

    Background Adverse drug events, the unintended and harmful effects of medications, are important outcome measures in health services research. Yet no universally accepted set of International Classification of Diseases (ICD) revision 10 codes or coding algorithms exists to ensure their consistent identification in administrative data. Our objective was to synthesize a comprehensive set of ICD-10 codes used to identify adverse drug events. Methods We developed a systematic search strategy and applied it to five electronic reference databases. We searched relevant medical journals, conference proceedings, electronic grey literature and bibliographies of relevant studies, and contacted content experts for unpublished studies. One author reviewed the titles and abstracts for inclusion and exclusion criteria. Two authors reviewed eligible full-text articles and abstracted data in duplicate. Data were synthesized in a qualitative manner. Results Of 4241 titles identified, 41 were included. We found a total of 827 ICD-10 codes that have been used in the medical literature to identify adverse drug events. The median number of codes used to search for adverse drug events was 190 (IQR 156–289) with a large degree of variability between studies in the numbers and types of codes used. Authors commonly used external injury (Y40.0–59.9) and disease manifestation codes. Only two papers reported on the sensitivity of their code set. Conclusions Substantial variability exists in the methods used to identify adverse drug events in administrative data. Our work may serve as a point of reference for future research and consensus building in this area. PMID:24222671

  2. Influence of B2O3 content on sintering behaviour and dielectric properties of La2O3-B2O3-CaO/Al2O3 glass-ceramic composites for LTCC applications

    NASA Astrophysics Data System (ADS)

    Wang, F. L.; Zhang, Y. W.; Chen, X. Y.; Mao, H. J.; Zhang, W. J.

    2018-01-01

    La2O3-B2O3-CaO glasses with different B2O3 content were synthesized by melting method to produce glass/ceramic composites in this work. XRD and DSC results revealed that the diminution of B2O3 content was beneficial to increase the crystallization tendency of glass and improve the quality of crystalline phase, while decreasing the effect of glass during sintering process as sintering aids. The choice of glass/ceramic mass ratio was also influenced by the B2O3 content of glass. Dense samples sintered at 875 ºC showed good dielectric properties which meet the requirement of LTCC applications: moderate dielectric constant (7.8-9.4) and low dielectric loss (2.0×10-3).

  3. Fabrication of SiO2@ZrO2@Y2O3:Eu3+ core-multi-shell structured phosphor.

    PubMed

    Gao, Xuan; He, Diping; Jiao, Huan; Chen, Juan; Meng, Xin

    2011-08-01

    ZrO2 interface was designed to block the reaction between SiO2 and Y2O3 in SiO2@Y2O3:Eu coreshell structure phosphor. SiO2@ZrO2@Y2O3:Eu core-multi-shell phosphors were successfully synthesized by combing an LBL method with a Sol-gel process. Based on electron microscopy, X-ray diffraction, and spectroscopy experiments, compelling evidence for the formation of the Y2O3:Eu outer shell on ZrO2 were presented. The presence of ZrO2 layer on SiO2 core can block the reaction of SiO2 core and Y2O3 shell effectively. By this kind of structure, the reaction temperature of the SiO2 core and Y2O3 shell in the SiO2@Y2O3:Eu core-shell structure phosphor can be increased about 200-300 degrees C and the luminescent intensity of this structure phosphor can be improved obviously. Under the excitation of ultraviolet (254 nm), the Eu3+ ion mainly shows its characteristic red (611 nm, 5D0-7F2) emissions in the core-multi-shell particles from Y2O3:Eu3+ shells. The emission intensity of Eu3+ ions can be tuned by the annealing temperatures, the number of coating times, and the thickness of ZrO2 interface, respectively.

  4. The impact of remote monitoring of implanted cardioverter-defibrillator (ICD) and cardiac resynchronisation therapy device (CRT-D) patients on healthcare costs in the Silesian population: three-year follow-up.

    PubMed

    Buchta, Piotr; Tajstra, Mateusz; Kurek, Anna; Skrzypek, Michał; Świetlińska, Małgorzata; Gadula-Gacek, Elżbieta; Wasiak, Michał; Pyka, Łukasz; Gąsior, Mariusz

    2017-01-01

    The population of patients with implanted cardioverter-defibrillators (ICD) and cardiac resynchronisation therapy devices (CRT-D) is constantly growing. The use of remote-monitoring (RM) techniques in this group can significantly improve clinical outcomes, but there are limited data about the impact of RM on healthcare costs from a payer's perspective. The aim of the study was to assess the impact on costs for the healthcare system of RM in patients with ICD or CRT-D. We examined a cohort of 842 patients with ICD or CRT-D. The group was divided into two groups based on RM (or no RM [NRM]), matched according to important clinical characteristics. The subjects were followed for a maximum of three years after implantation (mean follow-up 2.11 ± 0.83 years). The overall costs for the healthcare provider in the follow-up were defined as the primary endpoint. The secondary endpoint was the use of different types of medical contact events: hospitalisation and number of in-clinic and general practitioner visits (without the number of remote transmissions). In the three-year follow-up, the reduction in the costs of treatment for National Health Care in the RM group was 33.5% (median value, p < 0.001). In patients with implanted CRT-D, the reduction reached 42.7% (p = 0.011), and with ICD it was 31.3% (p = 0.007). We observed no significant reduction in the median hospitalisation costs in the three-year follow-up in the RM group (p = NS), despite a 25% drop in the mean value. The costs of outpatient visits were slightly higher in the RM group (p = NS). In the follow-up period, there was no reduction in the number of medical contact events (p = NS). Remote monitoring in patients with implanted ICD or CRT-D devices reduces the cost for the national healthcare provider.

  5. Nb K-edge x-ray absorption investigation of the pressure induced amorphization in A-site deficient double perovskite La1/3NbO3.

    PubMed

    Marini, C; Noked, O; Kantor, I; Joseph, B; Mathon, O; Shuker, R; Kennedy, B J; Pascarelli, S; Sterer, E

    2016-02-03

    Nb K-edge x-ray absorption spectroscopy is utilized to investigate the changes in the local structure of the A-site deficient double perovskite La1/3NbO3 which undergoes a pressure induced irreversible amorphization. EXAFS results show that with increasing pressure up to 7.5 GPa, the average Nb-O bond distance decreases in agreement with the expected compression and tilting of the NbO6 octahedra. On the contrary, above 7.5 GPa, the average Nb-O bond distance show a tendency to increase. Significant changes in the Nb K-edge XANES spectrum with evident low energy shift of the pre-peak and the absorption edge is found to happen in La1/3NbO3 above 6.3 GPa. These changes evidence a gradual reduction of the Nb cations from Nb(5+) towards Nb(4+) above 6.3 GPa. Such a valence change accompanied by the elongation of the average Nb-O bond distances in the octahedra, introduces repulsion forces between non-bonding adjacent oxygen anions in the unoccupied A-sites. Above a critical pressure, the Nb reduction mechanism can no longer be sustained by the changing local structure and amorphization occurs, apparently due to the build-up of local strain. EXAFS and XANES results indicate two distinct pressure regimes having different local and electronic response in the La1/3NbO3 system before the occurence of the pressure induced amorphization at  ∼14.5 GPa.

  6. Material properties of perovskites in the quasi-ternary system LaFeO3-LaCoO3-LaNiO3

    NASA Astrophysics Data System (ADS)

    Tietz, F.; Arul Raj, I.; Ma, Q.; Baumann, S.; Mahmoud, A.; Hermann, R. P.

    2016-05-01

    An overview is presented on the variation of electrical conductivity, oxygen permeation, and thermal expansion coefficient as a function of the composition of perovskites in the quasi-ternary system LaFeO3-LaCoO3-LaNiO3. Powders of thirteen nominal perovskite compositions were synthesized under identical conditions by the Pechini method. The powder X-ray diffraction data of two series, namely La(Ni0.5Fe0.5)1-xCoxO3 and LaNi0.5-xFexCo0.5O3, are presented after the powders had been sintered at 1100 °C for 6 h in air. The measurements revealed a rhombohedral structure for all compositions except LaNi0.5Fe0.5O3 for which 60% rhombohedral and 40% orthorhombic phase was found. The maximum DC electrical conductivity value of the perovskites at 800 °C was 1229 S cm-1 for the composition LaCoO3 and the minimum was 91 S cm-1 for the composition LaCo0.5Fe0.5O3. The oxygen permeation of samples with promising conductivities at 800 °C was one order of magnitude lower than that of La0.6Sr0.4Co0.8Fe0.2O3 (LSCF). The highest value of 0.017 ml cm-2 min-1 at 950 °C was obtained with LaNi0.5Co0.5O3. The coefficients of thermal expansion varied in the range of 13.2×10-6 K-1 and 21.9×10-6 K-1 for LaNi0.5Fe0.5O3 and LaCoO3, respectively. 57Fe Mössbauer spectroscopy was used as probe for the oxidation states, local environment and magnetic properties of iron ions as a function of chemical composition. The substitution had a great influence on the chemical properties of the materials.

  7. Unraveling the distinct luminescence thermal quenching behaviours of A/B-site Eu3+ ions in double perovskite Sr2CaMoO6:Eu3+

    NASA Astrophysics Data System (ADS)

    Wang, Chunhao; Ye, Shi; Zhang, Qinyuan

    2018-01-01

    Eu3+-doped Sr2CaMoO6 phosphors have a broad excitation band at around 350-425 nm, which meets the demand of Near-ultraviolet (NUV, 365-410 nm) absorption when applied in NUV-excitable phosphor-converted white light emitting diodes (WLEDs). The luminescence thermal quenching effects of Eu3+ ions at A/B sites (612 nm/593 nm) in Sr2CaMoO6 might be distinct with resultant emission colour variation, which is less studied but of significance for a scientific perspective. This research investigates on the temperature-dependent luminescence and decay curves of the nominal Sr1.9Li0.05Eu0.05CaMoO6 and Sr2Ca0.9Li0.05Eu0.05MoO6 phosphors. Results indicate that the luminescence of B-site Eu3+ ions is quenched more easily than that of A-site Eu3+ ions, directly evidenced by the fast and slow decay components in the decay curves. A distortion of B-site octahedron with elevating temperature and strong coupling with phonons may be partially responsible for the relatively poor thermal quenching behaviors of B-site Eu3+ ions. The research gives perspective on the thermal quenching of emissive lanthanide ions at different sites in phosphors.

  8. Understanding cation ordering and oxygen vacancy site preference in Ba3CaNb2O9 from first-principles

    NASA Astrophysics Data System (ADS)

    Ding, Hepeng; Virkar, Anil; Liu, Feng

    2014-03-01

    We investigate the physical mechanism underlying the formation of the B-site cation ordering and the oxygen vacancy site selection in Ba3CaNb2O9 using density functional theory calculations. We found that either cation site exchange or oxygen vacancy formation induces negligible lattice strain. This implies that the ionic radius plays an insignificant role in governing these two processes. Furthermore, the electrostatic interactions are found dominant in the ordering of mixed valence species on one or more sites, the ionic bond strength is identified as the dominant force in governing both the 1:2 B-site cation ordering along the <111>direction and the oxygen vacancy site preference in Ba3CaNb2O9. Specifically, the cation ordering can be rationalized by the increased mixing bonding energy of the Ca-O-Nb bonds over the Ca-O-Ca and Nb-O-Nb bonds, i.e., 1/2(Ca-O-Ca + Nb-O-Nb) O-Nb while oxygen vacancy prefers a site to minimize the electrostatic energy and to break the weaker B-O-B bond. Funded by DOE EFRC Grant Number DE-SC0001061 as a flow through from the University of South Carolina.

  9. Syntheses and characterization of phosphonates and diphosphonates of molybdenum, A4[(MoO3)5(O3PR)2]·xH2O, A2[Mo2O5(O3PR)2] and A2[Mo2O5(O3P-R-PO3)] (A = K, Rb, Cs, Tl, NH4).

    PubMed

    Elias Jesu Packiam, D; Vidyasagar, Kanamaluru

    2017-11-28

    Twenty new molybdenum phosphonates and diphosphonates have been synthesized and structurally characterized by single crystal and powder X-ray diffraction, CHN analyses, spectroscopic and thermal studies. Four of them are molecular phenyl- and benzyl-phosphonates containing discrete [(MoO 3 ) 5 (O 3 PR) 2 ] 4- (R = Ph or CH 2 Ph) cyclic anions. The sixteen non-molecular compounds are layered isostructural phenylphosphonates, A 2 [Mo 2 O 5 (O 3 PPh) 2 ] (A = NH 4 , Tl, Rb, Cs) and K 1.5 (H 3 O) 0.5 [Mo 2 O 5 (O 3 PPh) 2 ] and the corresponding diphosphonate compounds with pillared anionic layers, A 2 [Mo 2 O 5 (O 3 P(CH 2 ) 3 PO 3 )], A 2 [Mo 2 O 5 (O 3 P(CH 2 ) 4 PO 3 )] and A 2 [Mo 2 O 5 (O 3 P(C 6 H 4 )PO 3 )]. The A + ions reside in the interlayer region as well as in the cavities within the anionic layers.

  10. LaTiO3/KTaO3 interfaces: A new two-dimensional electron gas system

    NASA Astrophysics Data System (ADS)

    Zou, K.; Ismail-Beigi, Sohrab; Kisslinger, Kim; Shen, Xuan; Su, Dong; Walker, F. J.; Ahn, C. H.

    2015-03-01

    We report a new 2D electron gas (2DEG) system at the interface between a Mott insulator, LaTiO3, and a band insulator, KTaO3. For LaTiO3/KTaO3 interfaces, we observe metallic conduction from 2 K to 300 K. One serious technological limitation of SrTiO3-based conducting oxide interfaces for electronics applications is the relatively low carrier mobility (0.5-10 cm2/V s) of SrTiO3 at room temperature. By using KTaO3, we achieve mobilities in LaTiO3/KTaO3 interfaces as high as 21 cm2/V s at room temperature, over a factor of 3 higher than observed in doped bulk SrTiO3. By density functional theory, we attribute the higher mobility in KTaO3 2DEGs to the smaller effective mass for electrons in KTaO3.

  11. Calculation of Phase Equilibria in the Y2O3-Yb2O3-ZrO2 System

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Liu, Zi-Kui; Kaufman, Larry; Zhang, Fan

    2001-01-01

    Rare earth oxide stabilized zirconias find a wide range of applications. An understanding of phase equilibria is essential to all applications. In this study, the available phase boundary data and thermodynamic data is collected and assessed. Calphad-type databases are developed to completely describe the Y2O3-ZrO2, Yb2O3-ZrO2, and Y2O3-Yb2O3 systems. The oxide units are treated as components and regular and subregular solution models are used. The resultant calculated phase diagrams show good agreement with the experimental data. Then the binaries are combined to form the database for the Y2O3-Yb2O3-ZrO2 psuedo-ternary.

  12. Role of Automatic Wireless Remote Monitoring Immediately Following ICD Implant: The Lumos-T Reduces Routine Office Device Follow-Up Study (TRUST) Trial.

    PubMed

    Varma, Niraj; Epstein, Andrew E; Schweikert, Robert; Michalski, Justin; Love, Charles J

    2016-03-01

    The incidence of unscheduled encounters and problem occurrence between ICD implant and first in-person evaluation (IPE) recommended at 12 weeks is unknown. Automatic remote home monitoring (HM) may be useful in this potentially unstable period. ICD patients were randomized 2:1 to HM enabled post-implant (n = 908) or to conventional monitoring (CM; n = 431). Groups were compared between implant and prior to first scheduled IPE for IPE incidence, causes, and actionability (reprogramming, system revision, medication changes) and event detection time. HM and CM patients were similar (mean age 63 years, 72% male, LVEF 29%, primary prevention 73%, DDD 57%). In the post-implant interval assessed (HM 100 ± 21.3 days vs. CM 101 ± 20.8 days, P = 0.54), 85.4% (776/908) HM patients and 87.7% CM (378/431) patients had no cause for IPE (P = 0.31). When IPE occurred, actionability in HM (64/177 [36.2%]) was greater versus CM (15/62 [24.2%], P = 0.12). Actionable items were discovered sooner with HM (P = 0.025). Device reprogramming or lead revision was triggered following 53/177 (29.9%) IPEs in HM versus 9/62 (14.5%) in CM (P = 0.018). Arrhythmia detection was enhanced by HM: 276 atrial and ventricular episodes were detected in 135 follow-ups in contrast to CM (65 episodes at 17 IPEs). More silent arrhythmic episodes were discovered by HM (7.2% vs. 1.5% [P = 0.15]). Since 27/42 (64.3%) IPEs driven by HM alerts were actionable, event notification was a valuable method for problem detection. Importantly, HM did not increase incidence of non-actionable IPEs (P = 0.72). Activation of automatic remote monitoring should be encouraged soon post-ICD implant. © 2015 Wiley Periodicals, Inc.

  13. Temperature compensation effects of TiO2 on Ca[(Li1/3Nb2/3)0.8Sn0.2]O3-δ microwave dielectric ceramic

    NASA Astrophysics Data System (ADS)

    Hu, Mingzhe; Wei, Huanghe; Xiao, Lihua; Zhang, Kesheng; Hao, Yongde

    2017-10-01

    The crystal structure and dielectric properties of TiO2-modified Ca[(Li1/3Nb2/3)0.8Sn0.2]O3-δ microwave ceramics are investigated in the present paper. The crystal structure is probed by XRD patterns and their Rietveld refinement, results show that a single perovskite phase is formed in TiO2-modified Ca[(Li1/3Nb2/3)0.8Sn0.2]O3-δ ceramics with the crystal structure belonging to the orthorhombic Pbnm 62 space group. Raman spectra results indicate that the B-site order-disorder structure transition is a key point to the dielectric loss of TiO2-modified Ca[(Li1/3Nb2/3)0.8Sn0.2]O3-δ ceramics at microwave frequencies. After properly modified by TiO2, the large negative temperature coefficient of Ca[(Li1/3Nb2/3)0.8Sn0.2]O3-δ ceramic can be compensated and the optimal microwave dielectric properties can reach 𝜀r = 25.66, Qf = 18,894 GHz and TCF = -6.3 ppm/∘C when sintered at 1170∘C for 2.5 h, which manifests itself for potential use in microwave dielectric devices for modern wireless communication.

  14. Impedance spectroscopy of V2O5-Bi2O3-BaTiO3 glass-ceramics

    NASA Astrophysics Data System (ADS)

    Al-syadi, Aref M.; Yousef, El Sayed; El-Desoky, M. M.; Al-Assiri, M. S.

    2013-12-01

    The glasses within composition as: (80 - x)V2O5/20Bi2O3/xBaTiO3 with x = 2.5, 5, 7.5 and 10 mol% have been prepared. The glass transition (Tg) increases with increasing BaTiO3 content. Synthesized glasses ceramic containing BaTi4O9, Ba3TiV4O15 nanoparticles of the order of 25-35 nm and 30-46 nm, respectively were estimated using XRD. The dielectric properties over wide ranges of frequencies and temperatures were investigated as a function of BaTiO3 content by impedance spectroscopy measurements. The hopping frequency, ωh, dielectric constant, ɛ', activation energies for the DC conduction, Eσ, the relaxation process, Ec, and stretched exponential parameter β of the glasses samples have been estimated. The, ωh,β, decrease from 51.63 to 0.31 × 106 (s-1), 0.84 to 0.79 with increasing BaTiO3 respectively. Otherwise, the Eσ, increase from 0.279 to 0.306 eV with increasing BaTiO3. The value of dielectric constant equal 9.5·103 for the 2.5BaTiO3/77.5V2O5/20Bi2O3 glasses-ceramic at 330 K for 1 KHz which is ten times larger than that of same glasses composition. Finally the relaxation properties of the investigated glasses are presented in the electric modulus formalism, where the relaxation time and the respective activation energy were determined.

  15. Spectroscopic properties of Er(3+)/Yb(3+) co-doped Bi(2)O(3)-B(2)O(3)-GeO(2) glasses.

    PubMed

    Zhang, Xudong; Xu, Tiefeng; Nie, Qiuhua; Dai, Shixun; Shen, Xiang; Zhang, Xianghua

    2007-05-01

    Er(3+)/Yb(3+) co-doped 60Bi(2)O(3)-(40 - x)B(2)O(3)-xGeO(2) (BBG; x=0, 5, 10, 15 mol%) glasses that are suitable for fiber lasers, amplifiers have been fabricated and characterized. The absorption spectra, emission spectra, and lifetime of the (4)I(13/2) level and quantum efficiency of Er(3+):(4)I(13/2) --> (4)I(15/2) transition were measured and calculated. With the substitution of GeO(2) for B(2)O(3), both Delta lambda(eff) and sigma(e) decrease from 75 to 71 nm and 9.88 to 8.12 x 10(-21) cm(2), respectively. The measured lifetime of the (4)I(13/2) level and quantum efficiency of Er(3+):(4)I(13/2) --> (4)I(15/2) transition increase from 1.18 to 1.5 ms and 36.2% to 43.2%, respectively. The emission spectra of Er(3+):(4)I(13/2) --> (4)I(15/2) transition was also analyzed using a peak-fit routine, and an equivalent four-level system was proposed to estimate the stark splitting for the (4)I(15/2) and (4)I(13/2) levels of Er(3+) in the BBG glasses. The results indicate that the (4)I(13/2) --> (4)I(15/2) emission of Er(3+) can be exhibit a considerable broadening due to a significant enhance the peak A, and D emission.

  16. Synthesis and properties of γ-Ga2O3-Al2O3 solid solutions

    NASA Astrophysics Data System (ADS)

    Afonasenko, T. N.; Leont'eva, N. N.; Talzi, V. P.; Smirnova, N. S.; Savel'eva, G. G.; Shilova, A. V.; Tsyrul'nikov, P. G.

    2017-10-01

    The textural and structural properties of mixed oxides Ga2O3-Al2O3, obtained via impregnating γ-Al2O3 with a solution of Ga(NO3)3 and subsequent heat treatment, are studied. According to the results from X-ray powder diffraction, gallium ions are incorporated into the structure of aluminum oxide to form a solid solution of spinel-type γ-Ga2O3-Al2O3 up to a Ga2O3 content of 50 wt % of the total weight of the sample, accompanied by a reduction in the specific surface area, volume, and average pore diameter. It is concluded that when the Ga2O3 content exceeds 50 wt %, the β-Ga2O3 phase is observed along with γ-Ga2O3-Al2O3 solid solution. 71Ga and 27Al NMR spectroscopy shows that gallium replaces aluminum atoms from the tetrahedral position to the octahedral coordination in the structure of γ-Ga2O3-Al2O3.

  17. Hydrodeoxygenation of p -Cresol over Pt/Al 2 O 3 Catalyst Promoted by ZrO 2 , CeO 2 , and CeO 2 –ZrO 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Weiyan; Wu, Kui; Liu, Pengli

    2016-07-20

    ZrO 2-Al 2O 3 and CeO 2-Al 2O 3 were prepared by a co-precipitation method and selected as supports for Pt catalysts. The effects of CeO 2 and ZrO 2 on the surface area and Brønsted acidity of Pt/Al 2O 3 were studied. In the hydrodeoxygenation (HDO) of p-cresol, the addition of ZrO 2 promoted the direct deoxygenation activity on Pt/ZrOO 2-Al 2O 3 via Caromatic-O bond scission without benzene ring saturation. Pt/CeOO 2-Al 2O 3 exhibited higher deoxygenation extent than Pt/Al 2O 3 due to the fact that Brønsted acid sites on the catalyst surface favored the adsorption ofmore » p-cresol. With the advantages of CeO 2 and ZrO 2 taken into consideration, CeO 2-ZrOO 2-Al 2O 3 was prepared, leading to the highest HDO activity of Pt/CeO 2-ZrOO 2-Al 2O 3. The deoxygenation extent for Pt/CeO 2-ZrOO 2-Al 2O 3 was 48.4% and 14.5% higher than that for Pt/ZrO2O 2-Al 2O 3 and Pt/CeOO 2-Al 2O 3, respectively.« less

  18. [Chronic pain disorder with somatic and psychological factors (F45.41) : Validation criteria on operationalization of the ICD-10-GM diagnosis].

    PubMed

    Arnold, B; Lutz, J; Nilges, P; Pfingsten, M; Rief, Winfried; Böger, A; Brinkschmidt, T; Casser, H-R; Irnich, D; Kaiser, U; Klimczyk, K; Sabatowski, R; Schiltenwolf, M; Söllner, W

    2017-12-01

    In 2009 the diagnosis chronic pain disorder with somatic and psychological factors (F45.41) was integrated into the German version of the International Classification of Diseases, version 10 (ICD-10-GM). In 2010 Paul Nilges and Winfried Rief published operationalization criteria for this diagnosis. In the present publication the ad hoc commission on multimodal interdisciplinary pain therapy of the German Pain Society now presents a formula for a clear validation of these operationalization criteria of the ICD code F45.41.

  19. Crystal field excitations from Yb3 + ions at defective sites in highly stuffed Yb2Ti2O7

    NASA Astrophysics Data System (ADS)

    Sala, G.; Maharaj, D. D.; Stone, M. B.; Dabkowska, H. A.; Gaulin, B. D.

    2018-06-01

    The pyrochlore magnet Yb2Ti2O7 has been proposed as a quantum spin ice candidate, a spin liquid state expected to display emergent quantum electrodynamics with gauge photons among its elementary excitations. However, Yb2Ti2O7 's ground state is known to be very sensitive to its precise stoichiometry. Powder samples, produced by solid-state synthesis at relatively low temperatures, tend to be stoichiometric, while single crystals grown from the melt tend to display weak "stuffing" wherein ˜2 % of the Yb3 +, normally at the A site of the A2B2O7 pyrochlore structure, reside as well at the B site. In such samples Yb3 + ions should exist in defective environments at low levels and be subjected to crystalline electric fields very different from those at the stoichiometric A sites. Neutron scattering measurements of Yb3 + in four compositions of Yb2 +xTi2 -xO7 -y show the spectroscopic signatures for these defective Yb3 + ions and explicitly demonstrate that the spin anisotropy of the Yb3 + moment changes from X Y -like for stoichiometric Yb3 + to Ising-like for "stuffed" B site Yb3 + or for A site Yb3 + in the presence of oxygen vacancies.

  20. Substance dependence and non-dependence in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD): can an identical conceptualization be achieved?

    PubMed

    Saunders, John B

    2006-09-01

    This review summarizes the history of the development of diagnostic constructs that apply to repetitive substance use, and compares and contrasts the nature, psychometric performance and utility of the major diagnoses in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and International Classification of Diseases (ICD) diagnostic systems. The available literature was reviewed with a particular focus on diagnostic concepts that are relevant for clinical and epidemiological practice, and so that research questions could be generated that might inform the development of the next generation of DSM and ICD diagnoses. The substance dependence syndrome is a psychometrically robust and clinically useful construct, which applies to a range of psychoactive substances. The differences between the DSM fourth edition (DSM-IV) and the ICD tenth edition (ICD-10) versions are minimal and could be resolved. DSM-IV substance abuse performs moderately well but, being defined essentially by social criteria, may be culture-dependent. ICD-10 harmful substance use performs poorly as a diagnostic entity. There are good prospects for resolving many of the differences between the DSM and ICD systems. A new non-dependence diagnosis is required. There would also be advantages in a subthreshold diagnosis of hazardous or risky substance use being incorporated into the two systems. Biomedical research can be drawn upon to define a psychophysiological 'driving force' which could underpin a broad spectrum of substance use disorders.

  1. Determination of Problematic ICD-9-CM Subcategories for Further Study of Coding Performance: Delphi Method

    PubMed Central

    Zeng, Xiaoming; Bell, Paul D

    2011-01-01

    In this study, we report on a qualitative method known as the Delphi method, used in the first part of a research study for improving the accuracy and reliability of ICD-9-CM coding. A panel of independent coding experts interacted methodically to determine that the three criteria to identify a problematic ICD-9-CM subcategory for further study were cost, volume, and level of coding confusion caused. The Medicare Provider Analysis and Review (MEDPAR) 2007 fiscal year data set as well as suggestions from the experts were used to identify coding subcategories based on cost and volume data. Next, the panelists performed two rounds of independent ranking before identifying Excisional Debridement as the subcategory that causes the most confusion among coders. As a result, they recommended it for further study aimed at improving coding accuracy and variation. This framework can be adopted at different levels for similar studies in need of a schema for determining problematic subcategories of code sets. PMID:21796264

  2. A-site Ordered Chromium Perovskites, ACu3Cr4O12 with A = Trivalent Ions

    NASA Astrophysics Data System (ADS)

    Sugiyama, Jun; Nozaki, Hiroshi; Umegaki, Izumi; Higemoto, Wataru; Isobe, Masahiko; Takagi, Hidenori; Sakurai, Hiroya; Ansaldo, Eduardo J.; Brewer, Jess H.; Sassa, Yasmine; Forslund, Ola Kenji; Månsson, Martin

    The magnetic ground state of the A-site ordered chromium perovskites, ACu3Cr4O12 with A = Y, La, Eu, and Lu has been investigated with μ+SR using powder samples prepared by a high-pressure technique. Weak transverse field measurements revealed that the four compounds enter into a magnetic phase below 230-260 K. Moreover, the transition temperature (TN) was found to decrease with increasing the size of A3+ ions. Zero field measurements indicated the formation of static antiferromagnetic (AF) order in ACu3Cr4O12 below TN. Furthermore, since the internal magnetic field in the AF phase is independent of A, the role of 4f electrons on the AF state is very limited and/or eventually absence in ACu3Cr4O12.

  3. Preparation and characterization of BiFeO3/La0.7Sr0.3MnO3 heterostructure grown on SrTiO3 substrate

    NASA Astrophysics Data System (ADS)

    Zhao, Chenwei; Zhou, Chaochao; Chen, Changle

    2017-09-01

    In this paper, BiFeO3/La0.7Sr0.3MnO3 heterostructure is fabricated on the SrTiO (100) substrate using the pulsed laser deposition method (PLD). Magnetization hystersis loops of the BiFeO3/La0.7Sr0.3MnO3 heterostructure are obtained at 300 K and 80 K. The heterostructure exhibits evident ferromagnetic characteristic at both room temperature and 80 K. At 80 K, magnetization of the heterostructure is stronger than room temperature magnetic measure. The temperature dependence of resistance of the heterostructure with different currents is also studied. With different currents, there appears to be a peak resistance about 180 K. When I is 50 uA, ΔR is 68.4%. And when I is 100 uA, ΔR is 79.3%. The BiFeO3/La0.7Sr0.3MnO3 heterostructure exhibits a positive colossal magnetoresistance (MR) effect over a temperature range of 80-300 K. In our heterostructure, maximum magnetic resistance appears in 210 K, and MR = 44.34%. Mechanism analysis of the leakage current at room temperature shows that the leakage current is the interface-limited Schottky emission, but not dominated by the Poole-Frenkel emission or SCLC.

  4. Electron Mobility in γ -Al2O3/SrTiO3

    NASA Astrophysics Data System (ADS)

    Christensen, D. V.; Frenkel, Y.; Schütz, P.; Trier, F.; Wissberg, S.; Claessen, R.; Kalisky, B.; Smith, A.; Chen, Y. Z.; Pryds, N.

    2018-05-01

    One of the key issues in engineering oxide interfaces for electronic devices is achieving high electron mobility. SrTiO3 -based interfaces with high electron mobility have gained a lot of interest due to the possibility of combining quantum phenomena with the many functionalities exhibited by SrTiO3 . To date, the highest electron mobility (140 000 cm2/V s at 2 K) is obtained by interfacing perovskite SrTiO3 with spinel γ -Al2O3 . The origin of the high mobility, however, remains poorly understood. Here, we investigate the scattering mechanisms limiting the mobility in γ -Al2O3/SrTiO3 at temperatures between 2 and 300 K and over a wide range of sheet carrier densities. For T >150 K , we find that the mobility is limited by longitudinal optical phonon scattering. For large sheet carrier densities (>8 ×1013 cm-2 ), the screened electron-phonon coupling leads to room-temperature mobilities up to μ ˜12 cm2/V s . For 5 K O3 . At carrier densities higher than the optimum, the SrTiO3 heterostructure gradually becomes bulk conducting, and the electron mobility decreases to approximately 20 000 cm2/V s . We argue that the high electron mobility observed arises from a spatial separation of donors and electrons with oxygen-vacancy donors preferentially forming at the interface, whereas the itinerant electrons extend deeper into SrTiO3 . Understanding the scattering mechanism in γ -Al2O3/SrTiO3 paves the way for creation of high-mobility nanoscale electronic devices.

  5. Synthesis and spectral characterizations of trivalent ions (Cr3+, Fe3+) doped CdO nanopowders

    NASA Astrophysics Data System (ADS)

    Aswani, T.; Babu, B.; Pushpa Manjari, V.; Joyce Stella, R.; Thirumala Rao, G.; Rama Krishna, Ch.; Ravikumar, R. V. S. S. N.

    2014-03-01

    Trivalent transition metal ions (Cr3+, Fe3+) doped CdO nanopowders via sonication in the presence of Sodium lauryl sulfate as stabilizing agent were synthesized and characterized. Powder XRD studies indicate that the obtained CdO has a cubic phase and concluded that the trivalent ions doping induced the lattice constants to change some extent. Optical absorption spectra exhibited the characteristic bands of Cr3+ and Fe3+ ions in octahedral site symmetry. Crystal field (Dq) and inter-electronic repulsion (B and C) parameters are evaluated for Cr3+ doped CdO nanopowders as Dq = 1540, B = 619 and C = 3327 cm-1 and for Fe3+ doped CdO nanopowders Dq = 920, B = 690, C = 2750 cm-1. EPR spectra of the Cr3+ and Fe3+ doped CdO nanopowders exhibited resonances at g = 1.973 and g = 2 respectively which indicate distorted octahedral site for both ions with the host. Photoluminescence spectra shows the emission bands in violet and bluish green regions for Cr3+ doped CdO, ultraviolet and blue emissions for Fe3+ doped CdO nanopowders. The CIE chromaticity coordinates were also evaluated from the emission spectrum. FT-IR spectra indicate the presence of various functional groups of host lattice.

  6. Characteristics of ventricular fibrillation in relation to cardiac aetiology and shock success: A waveform analysis study in ICD-patients.

    PubMed

    Bonnes, Judith L; Keuper, Wessel; Westra, Sjoerd W; Zegers, Erwin S; Oostendorp, Thom F; Brouwer, Marc A; Smeets, Joep L R M

    2015-01-01

    Ventricular fibrillation (VF) waveform characteristics are associated with cardiac arrest duration and defibrillation success. Recent animal studies found that VF characteristics and shock success also depend on the presence of myocardial infarction (MI). In patients, VF induction after implantable cardioverter defibrillator (ICD) implantation offers a unique setting to study early VF characteristics: we studied the relation with cardiac disease--either presence or absence of a previous MI--and with shock success. Retrospective cohort study of ICD-patients who underwent defibrillation testing, 117 (63%) with and 69 (37%) without a previous MI. Intracardiac recordings of induced VF were analysed using Fourier analysis. In previous MI-patients, the fundamental frequency and organisation index of the VF signal were significantly lower as compared with patients without a previous MI: 4.9 Hz ± 0.6 vs. 5.2 Hz ± 0.6 (p = 0.005) and 56% ± 10 vs. 60% ± 9 (p = 0.001), respectively. The median frequency was not different (p = 0.25). We found no association between VF characteristics and ICD shock success. In analogy with observations in animals, we found that a history of a previous MI was associated with slower and less organised VF. In our cohort of ICD-patients, early VF waveform characteristics were not associated with shock outcomes. Further study is warranted to determine to what extent VF characteristics are influenced by the underlying aetiology on the one hand, and time delay on the other. These findings could improve insight into the potential value of VF analysis to guide shock delivery. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Intellectual developmental disorders: towards a new name, definition and framework for "mental retardation/intellectual disability" in ICD-11.

    PubMed

    Salvador-Carulla, Luis; Reed, Geoffrey M; Vaez-Azizi, Leila M; Cooper, Sally-Ann; Martinez-Leal, Rafael; Bertelli, Marco; Adnams, Colleen; Cooray, Sherva; Deb, Shoumitro; Akoury-Dirani, Leyla; Girimaji, Satish Chandra; Katz, Gregorio; Kwok, Henry; Luckasson, Ruth; Simeonsson, Rune; Walsh, Carolyn; Munir, Kemir; Saxena, Shekhar

    2011-10-01

    Although "intellectual disability" has widely replaced the term "mental retardation", the debate as to whether this entity should be conceptualized as a health condition or as a disability has intensified as the revision of the World Health Organization (WHO)'s International Classification of Diseases (ICD) advances. Defining intellectual disability as a health condition is central to retaining it in ICD, with significant implications for health policy and access to health services. This paper presents the consensus reached to date by the WHO ICD Working Group on the Classification of Intellectual Disabilities. Literature reviews were conducted and a mixed qualitative approach was followed in a series of meetings to produce consensus-based recommendations combining prior expert knowledge and available evidence. The Working Group proposes replacing mental retardation with intellectual developmental disorders, defined as "a group of developmental conditions characterized by significant impairment of cognitive functions, which are associated with limitations of learning, adaptive behaviour and skills". The Working Group further advises that intellectual developmental disorders be incorporated in the larger grouping (parent category) of neurodevelopmental disorders, that current subcategories based on clinical severity (i.e., mild, moderate, severe, profound) be continued, and that problem behaviours be removed from the core classification structure of intellectual developmental disorders and instead described as associated features.

  8. Physical and electrical properties of SrTiO3 and SrZrO3

    NASA Astrophysics Data System (ADS)

    Fashren Muhamad, Norhizatol; Aina Maulat Osman, Rozana; Sobri Idris, Mohd; Yasin, Mohd Najib Mohd

    2017-11-01

    Perovskite type oxide strontium titanate (SrTiO3) and strontium zirconate (SrZrO3) ceramic powder has been synthesized using conventional solid state reaction method. The powders were mixed and ground undergone calcinations at 1400°C for 12 h and sintered at 1550°C for 5h. X-ray Diffraction exposes physical properties SrTiO3 which exhibit cubic phase (space group: pm-3m) at room temperature meanwhile SrZrO3 has Orthorhombic phase (space group: pnma). The electrical properties such as dielectric constant (ɛr), dielectric loss (tan δ), and conductivity (σ) were studied in variation temperature and frequency. High dielectric constant of SrTiO3 and SrZrO3 were observed at 10 kHz for both samples about 240 and 21 respectively at room temperature. The dielectric loss of SrTiO3 and SrZrO3 is very low loss value approximately 0.00076 and 0.67512 indicates very good dielectric.

  9. 3-O-methyl sugars as constituents of glycoproteins. Identification of 3-O-methylgalactose and 3-O-methylmannose in pulmonate gastropod haemocyanins.

    PubMed Central

    Hall, R L; Wood, E J; Kamberling, J P; Gerwig, G J; Vliegenthart, F G

    1977-01-01

    In addition to the already knownonosaccharides fucose, xylose, mannose, galactose, glucose, N-acetylgalactosamine and N-acetylglucosamine, the carbohydrate part of the haemocyanin from Helix pomatia (Roman snail) contains 3-O-methylgalactose, and that from Lymnaea stagnalis (a freshwater snail) 3-O-methylgalactose and 3-O-methylmannose. The 3-O-methyl sugars were identified by g.l.c.-mas spectrometry of the corresponding trimethylsilyl methyl glycosides and the alditol acetates, and by co-chromatography with the synthetic reference substances. PMID:889564

  10. Delirium diagnosis defined by cluster analysis of symptoms versus diagnosis by DSM and ICD criteria: diagnostic accuracy study.

    PubMed

    Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Meagher, David J; Palma, José; Viñuelas, Eva; Grau, Imma; Vilella, Elisabet; de Pablo, Joan

    2016-05-26

    Information on validity and reliability of delirium criteria is necessary for clinicians, researchers, and further developments of DSM or ICD. We compare four DSM and ICD delirium diagnostic criteria versions, which were developed by consensus of experts, with a phenomenology-based natural diagnosis delineated using cluster analysis of delirium features in a sample with a high prevalence of dementia. We also measured inter-rater reliability of each system when applied by two evaluators from distinct disciplines. Cross-sectional analysis of 200 consecutive patients admitted to a skilled nursing facility, independently assessed within 24-48 h after admission with the Delirium Rating Scale-Revised-98 (DRS-R98) and for DSM-III-R, DSM-IV, DSM-5, and ICD-10 criteria for delirium. Cluster analysis (CA) delineated natural delirium and nondelirium reference groups using DRS-R98 items and then diagnostic systems' performance were evaluated against the CA-defined groups using logistic regression and crosstabs for discriminant analysis (sensitivity, specificity, percentage of subjects correctly classified by each diagnostic system and their individual criteria, and performance for each system when excluding each individual criterion are reported). Kappa Index (K) was used to report inter-rater reliability for delirium diagnostic systems and their individual criteria. 117 (58.5 %) patients had preexisting dementia according to the Informant Questionnaire on Cognitive Decline in the Elderly. CA delineated 49 delirium subjects and 151 nondelirium. Against these CA groups, delirium diagnosis accuracy was highest using DSM-III-R (87.5 %) followed closely by DSM-IV (86.0 %), ICD-10 (85.5 %) and DSM-5 (84.5 %). ICD-10 had the highest specificity (96.0 %) but lowest sensitivity (53.1 %). DSM-III-R had the best sensitivity (81.6 %) and the best sensitivity-specificity balance. DSM-5 had the highest inter-rater reliability (K =0.73) while DSM-III-R criteria were the least

  11. Direct spectroscopic evidence for isolated silanols in SiO x/Al 2O 3 and their formation mechanism

    DOE PAGES

    Mouat, Aidan R.; Kobayashi, Takeshi; Pruski, Marek; ...

    2017-02-27

    Here, the preparation and unambiguous characterization of isolated Brønsted-acidic silanol species on silica–alumina catalysts presents a key challenge in the rational design of solid acid catalysts. In this report, atomic layer deposition (ALD) and liquid-phase preparation (chemical liquid deposition, CLD) are used to install the SiO x sites on Al 2O 3 catalysts using the same Si source (tetraethylorthosilicate, TEOS). The ALD-derived and CLD-derived SiO x sites are probed with dynamic nuclear polarization (DNP)-enhanced 29Si– 29Si double-quantum/single-quantum (DQ/SQ) correlation NMR spectroscopy. The investigation reveals conclusively that the SiO x/Al 2O 3 material prepared by ALD and CLD, followed by calcinationmore » under an O 2 stream, contains fully spatially isolated Si species, in contrast with those resulting from the calcination under static air, which is widely accepted as a postgrafting treatment for CLD. Insight into the formation mechanism of these sites is obtained via in situ monitoring of the TEOS + γ-Al 2O 3 reaction in an environmental diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) cell. Upon calcination, the DRIFTS spectra of SiO x/Al 2O 3 reveal a signature unambiguously assignable to isolated Brønsted-acidic silanol species. Surprisingly, the results of this study indicate that the method of preparing SiO x/Al 2O 3 catalysts is less important to the final structure of the silanol sites than the post-treatment conditions. This finding should greatly simplify the methods for synthesizing site-isolated, Brønsted-acidic SiO x/Al 2O 3 catalysts.« less

  12. Effects of Dopant on Depoling Temperature in Modified BiScO3 - PbTiO3

    NASA Technical Reports Server (NTRS)

    Kowalski, Benjamin; Sehirlioglu, Alp

    2014-01-01

    In recent years there has been a renewed interest for high temperature piezoelectrics for both terrestrial and aerospace applications. These applications are limited in part by the operating temperature, which is usually taken as one half of the Curie temperature (Tc), and is 200C for one of the most widely used commercial piezoelectrics, Pb(Zr,Ti)O3 (PZT). In an effort to increase Tc, subsequent research into high temperature Bi(BB)O3 PbTiO3 piezoelectrics led to the discovery of the morphotropic phase boundary (MPB) in the high-Tc BiScO3 PbTiO3 (BS-PT) system with a Tc of 460C and a d33 of 460 pmV. The Tc marks the ferroelectric to paraelectric phase transformation and while, in general, a phase transformation leads to thermal depoling in piezoelectrics with low or moderate Tcs, for high Tc piezoelectrics thermally assisted dipole rotation can lead to randomization of domains at temperatures below Tc. It becomes necessary to determine the depoling temperature (Td) which dictates the actual working temperature range. By doping for Sc and Ti the Td can be shifted while maintaining similar electromechanical properties as a function of temperature. The effect of this B-site doping on depoling temperature has been explored through the characterization of microstructure and weakhigh field measurements.

  13. Synthesis and electrical properties of BaBiO 3 and high resistivity BaTiO 3 –BaBiO 3 ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Nitish; Golledge, Stephen L.; Cann, David P.

    2016-12-01

    Ceramics of the composition BaBiO3 (BB) were sintered in oxygen to obtain a single phase with monoclinic II2/mm symmetry as suggested by high-resolution X-ray diffraction. X-ray photoelectron spectroscopy confirmed the presence of bismuth in two valence states - 3+ and 5+. Optical spectroscopy showed presence of a direct bandgap at ~ 2.2eV and a possible indirect bandgap at ~ 0.9eV. This combined with determination of the activation energy for conduction of 0.25eV, as obtained from ac impedance spectroscopy, suggested that a polaron-mediated conduction mechanism was prevalent in BB. The BB ceramics were crushed, mixed with BaTiO3 (BT), and sintered tomore » obtain BT–BB solid solutions. All the ceramics had tetragonal symmetry and exhibited a normal ferroelectric-like dielectric response. Using ac impedance and optical spectroscopy, it was shown that resistivity values of BT–BB were orders of magnitude higher than BT or BB alone, indicating a change in the fundamental defect equilibrium conditions. A shift in the site occupancy of Bi to the A-site is proposed to be the mechanism for the increased electrical resistivity.« less

  14. Regional Relationship between CO and O3 in New England

    NASA Astrophysics Data System (ADS)

    Mao, H.; Talbot, R.

    2003-12-01

    The seasonality and interannual variability in the mixing ratios of ozone (O3) and carbon monoxide (CO) and their inter-relationship were investigated at the rural low elevation site Thompson Farm (TF) and the hill site Castle Springs (400 m above ground level) in southern New Hampshire using continuous observations (2001-2003) from the Atmospheric Investigation, Regional Modeling, Analysis and Prediction (AIRMAP) program at University of New Hampshire (UNH). Our results show distinct site-dependent characteristics in temporal variations on various time scales in O3 and CO and particularly large interannual variability in fall and winter at both sites. The grouped O3 and CO data, based on wind speed and direction over different time periods of the day, showed largely varying probability distribution functions (PDF). It was found that only 10% of the seasonal observations formed a positive O3-CO linear correlation, leading to an estimate of 370 M moles d-1 for O3 export from the northeastern U.S. This estimate is three times smaller than previous studies. We used a ratio analysis (NO/NOy and NOy/CO) to show that the linear O3-CO relationships were a result of multiple processes rather than simply either photochemical or depositonal loss processes as proposed by previous work. One of the most important features of the O3-CO relationship is the lower CO boundary, for which we attempeted to provide physical and chemical interpretations.

  15. Growth and Transport Studies of LaTiO3 / KTaO3 Heterostructures

    NASA Astrophysics Data System (ADS)

    Zou, K.; Walker, F. J.; Ahn, C. H.

    2014-03-01

    Perovskite oxide heterostructures provide a rich platform for exploring emergent electronic properties, such as 2D electron gases (2DEGs) at interfaces. In this talk, we present results on the growth of LaTiO3 / KTaO3 heterostructures by molecular beam epitaxy and subsequent measurements of transport properties. Although both oxide materials are insulating in the bulk, metallic conduction is observed from T = 2 - 300 K. We achieve a room temperature carrier mobility of ~ 25 cm2 /Vs at a carrier density of ~ 1014 /cm2. By comparison, 2DEGs in LaTiO3 / SrTiO3 and LaAlO3 / SrTiO3 have lower carrier mobility, but the same carrier density. We attribute some of the increase in mobility to the smaller band effective mass of the Ta 4d electrons compared to the Ti 3d electrons.

  16. Enhanced Energy-Storage Density and High Efficiency of Lead-Free CaTiO3-BiScO3 Linear Dielectric Ceramics.

    PubMed

    Luo, Bingcheng; Wang, Xiaohui; Tian, Enke; Song, Hongzhou; Wang, Hongxian; Li, Longtu

    2017-06-14

    A novel lead-free (1 - x)CaTiO 3 -xBiScO 3 linear dielectric ceramic with enhanced energy-storage density was fabricated. With the composition of BiScO 3 increasing, the dielectric constant of (1 - x)CaTiO 3 -xBiScO 3 ceramics first increased and then decreased after the composition x > 0.1, while the dielectric loss decreased first and increased. For the composition x = 0.1, the polarization was increased into 12.36 μC/cm 2 , 4.6 times higher than that of the pure CaTiO 3 . The energy density of 0.9CaTiO 3 -0.1BiScO 3 ceramic was 1.55 J/cm 3 with the energy-storage efficiency of 90.4% at the breakdown strength of 270 kV/cm, and the power density was 1.79 MW/cm 3 . Comparison with other lead-free dielectric ceramics confirmed the superior potential of CaTiO 3 -BiScO 3 ceramics for the design of ceramics capacitors for energy-storage applications. First-principles calculations revealed that Sc subsitution of Ti-site induced the atomic displacement of Ti ions in the whole crystal lattice, and lattice expansion was caused by variation of the bond angles and lenghths. Strong hybridization between O 2p and Ti 3d was observed in both valence band and conduction band; the hybridization between O 2p and Sc 3d at high conduction band was found to enlarge the band gap, and the static dielectric tensors were increased, which was the essential for the enhancement of polarization and dielectric properties.

  17. Interaction mechanisms between α-Fe2O3, γ-Fe2O3 and Fe3O4 nanoparticles and Citrus maxima seedlings.

    PubMed

    Li, Junli; Hu, Jing; Xiao, Lian; Wang, Yunqiang; Wang, Xilong

    2018-06-01

    The interactions between α-Fe 2 O 3 , γ-Fe 2 O 3 , and Fe 3 O 4 nanoparticles (NPs) and Citrus maxima seedlings were examined so as to better understand possible particle applications as an Fe source for crop plants. NPs toxicity to the exposed plant was investigated as well. The α- and γ-Fe 2 O 3 NPs were accumulated by plant root cells through diapirism and endocytosis, respectively, but translocation to the shoots was negligible. Analysis of malondialdehyde (MDA), soluble protein content, and antioxidant enzyme activity revealed that Fe deficiency induced strong oxidative stress in Citrus maxima seedlings, which followed an order of Fe deficiency>Fe 3+ >α-Fe 2 O 3 , γ-Fe 2 O 3 NPs>Fe 3 O 4 NPs. However, the chlorophyll leaf content of plants exposed to α-Fe 2 O 3 , γ-Fe 2 O 3 , Fe 3 O 4 NPs and Fe 3+ were significantly reduced by 31.1%, 14.8%, 18.8% and 22.0%, respectively, relative to the control. Furthermore, RT-PCR analysis revealed no up-regulation of AHA and Nramp3 genes in Citrus maxima roots; however, the relative FRO2 gene expression upon exposure to iron oxide NPs was 1.4-2.8-fold higher than the control. Ferric reductase activity was consistently enhanced upon iron oxide NPs exposure. These findings advance understanding of the interaction mechanisms between metal oxide NPs and plants, and provide important knowledge need for the possible application of these materials in agriculture. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Enhanced ferromagnetic order in Sr{sub 4}Mn{sub 3}O{sub 3}(GeO{sub 4}){sub 3} featuring canted [MnO{sub 4}]{sub ∞} spin chains of mixed-valent Mn(III)/Mn(IV). Aliovalent substitution of the Sr{sub 4−x}Ln{sub x}Mn{sup III}{sub 2+x}Mn{sup IV}{sub 1−x}O{sub 3}(GeO{sub 4}){sub 3} solid-solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, J. Palmer; Sulejmanovic, Dino; Becht, Gregory

    2013-10-15

    Crystals of Sr{sub 4−x}Ln{sub x}Mn{sub 3}O{sub 3}(GeO{sub 4}){sub 3} (x=0; x∼0.15 for Ln=La, Pr, Nd, Sm. Eu, Gd, Dy; x∼0.3 for Ln=Gd) were isolated upon using high-temperature, solid-state methods in molten-salt media. These compounds are isostructural with the previously reported Na{sub 3}LnMn{sub 3}O{sub 3}(AsO{sub 4}){sub 3} (Ln=La, Sm, Gd) series that contains the same [MnO{sub 4}]{sub ∞} spin chains. The synthesis of the Sr{sub 4}Mn{sub 3}O{sub 3}(GeO{sub 4}){sub 3} (x=0) phase was carried out by a double aliovalent substitution with respect to the Sr{sup 2+} and Ge{sup 4+} ions that replace Na{sup +}/Ln{sup 3+} and As{sup 5+} in Na{sub 3}LnMn{submore » 3}O{sub 3}(AsO{sub 4}){sub 3}, respectively. The title series contains mixed-valent Mn(III)/Mn(IV) and shows a limited range of solid solution, both of which were not observed in the previously reported Na{sub 3}LnMn{sub 3}O{sub 3}(AsO{sub 4}){sub 3} series. To form the Sr{sub 4−x}Ln{sub x}Mn{sub 3}O{sub 3}(GeO{sub 4}){sub 3} solid solution, one of the Sr{sup 2+} sites, i.e., the original Ln-site in Na{sub 3}LnMn{sub 3}O{sub 3}(AsO{sub 4}){sub 3}, is partially substituted by Ln{sup 3+} in a statistical disorder of Sr{sub 1−x}/Ln{sub x}. Initial magnetic investigations of selected derivatives reveal higher ferromagnetic ordering temperatures than those reported for the Na{sub 3}LnMn{sub 3}O{sub 3}(AsO{sub 4}){sub 3} series, presumably attributed to a lesser degree of canting as a result of introducing non-Jahn–Teller Mn{sup 4+} ions. Also intriguing is the observation of multiple anomalies at low temperatures which appear to be of electronic origins. - Graphical abstract: Sr{sub 4−x}Ln{sub x}Mn(III){sub 2+x}Mn(IV){sub 1−x}O{sub 3}(GeO{sub 4}){sub 3}. Display Omitted - Highlights: • Double aliovalent substitution: Sr{sub 4}Mn{sub 3}O{sub 3}(GeO{sub 4}){sub 3} with respect to Na{sub 3}LnMn{sub 3}O{sub 3}(AsO{sub 4}){sub 3}. • Solid solution with respect to statistical disorder of Sr{sub 1

  19. Echocardiography and cardiac MRI in mutation-negative hypertrophic cardiomyopathy in an older patient: a case defining the need for ICD.

    PubMed

    Rodriguez, Fatima; Degnan, Kathleen O; Seidman, Christine E; Mangion, Judy R

    2014-08-01

    We report the case of a 67-year-old man with hypertrophic cardiomyopathy who presented for a second opinion about implantable cardio-defibrillator (ICD) placement after a witnessed syncopal episode. Despite his older age, being mutation-negative, and having a maximal septal thickness of 2.2 cm on echocardiography, he demonstrated rapid progression of myocardial fibrosis on cardiac MRI, correlating to ventricular tachyarrhythmias and syncope. We review the role of echocardiography and cardiac MRI in optimizing medical care for such patients who may not otherwise meet criteria for an ICD placement or further interventions. © 2014, Wiley Periodicals, Inc.

  20. Magnetic transition in Y-site doped multiferroic YMnO3

    NASA Astrophysics Data System (ADS)

    Thakur, Rajesh K.; Thakur, Rasna; Gaur, N. K.

    2016-05-01

    We have synthesized polycrystalline hexagonal Y1-xSrxMnO3 (x=0.02, 0.1) compounds by using conventional solid state reaction method. The detailed structural investigations are carried out by using XRD studies which reveals the single phase formation of the reported compounds with hexagonal structure and space group P63cm (JCPDS: 25-1079). Further the XRD data of reported compounds were analyzed by RIETVELD (FULLPROFF) method which shows the decrease in the lattice parameter with increasing concentration of divalent strontium to Y-site. The observed pointed kinks in the specific heat study are indicative of the probable coupling in between the electric and magnetic orders in this class of materials. The reported systematic specific heat studies shows that the antiferromagnetic (AFM) transition temperature (TN) shifts to higher value with increasing concentration of Sr2+ ion in the YMnO3 compound which is attributed to the enhanced lattice contribution to the specific heat in the this compound. The present compound shows the independence of specific heat and magnetic transition temperature with applied magnetic field of 8T and 12T.

  1. Amphoteric doping of praseodymium Pr 3+ in SrTiO 3 grain boundaries

    DOE PAGES

    Yang, H.; Lee, H. S.; Kotula, P. G.; ...

    2015-03-26

    Charge Compensation in rare-earth Praseodymium (Pr 3+) doped SrTiO 3 plays an important role in determining the overall photoluminescence properties of the system. Here, the Pr 3+ doping behavior in SrTiO 3 grain boundaries (GBs) is analyzed using aberration corrected scanning transmission electron microscopy (STEM). The presence of Pr 3+ induces structure variations and changes the statistical prevalence of GB structures. In contrast to the assumption that Pr 3+ substitutes for A site as expected in the bulk, Pr 3+ is found to substitute both Sr and Ti sites inside GBs with the highest concentration in the Ti sites. Asmore » a result, this amphoteric doping behavior in the boundary plane is further confirmed by first principles theoretical calculations.« less

  2. Amphoteric Doping of Praseodymium Pr3+ in SrTiO3 Grain Boundaries

    DOE PAGES

    Yang, Hao; Lee, H. S.; Kotula, Paul G.; ...

    2015-03-23

    Charge Compensation in rare-earth Praseodymium (Pr 3+) doped SrTiO 3 plays an important role in determining the overall photoluminescence properties of the system. Here, the Pr 3+ doping behavior in SrTiO 3 grain boundaries (GBs) is analyzed using aberration corrected scanning transmission electron microscopy (STEM). The presence of Pr 3+ induces structure variations and changes the statistical prevalence of GB structures. In contrast to the assumption that Pr 3+ substitutes for A site as expected in the bulk, Pr 3+ is found to substitute both Sr and Ti sites inside GBs with the highest concentration in the Ti sites. Asmore » a result, this amphoteric doping behavior in the boundary plane is further confirmed by first principles theoretical calculations.« less

  3. Plumboselite, Pb3O2(SeO3), a new oxidation-zone mineral from Tsumeb, Namibia

    NASA Astrophysics Data System (ADS)

    Kampf, Anthony R.; Mills, Stuart J.; Pinch, William W.

    2011-01-01

    Plumboselite, ideally Pb3O2(SeO3), is a new selenite (IMA2010-028) from the Tsumeb mine, Namibia. It occurs as fibres on clausthalite and is also associated with smithsonite, mimetite and vaterite. Plumboselite occurs in subparallel to divergent clusters of thin, flattened, colourless fibres up to 0.3 mm in length, but not exceeding 5 μm in width and 2 μm in thickness. The fibres are elongated parallel to [001] and flattened on {010}, with {010} the only form observed. The crystals have a dull to adamantine lustre and a white streak. The tenacity is brittle and the Mohs hardness is estimated to be between 2 and 3. Plumboselite crystals are optically biaxial with parallel extinction and are length fast in all orientations. The Gladstone-Dale relationship predicts n av = 2.115. The high indices of refraction and small crystal size prevented the determination of other optical properties. The calculated density is 7.814 g/cm3. The empirical formula (based on 5 O atoms) is Pb2.92Ca0.01Se1.03O5. Plumboselite is orthorhombic, space group Cmc21, a = 10.5384(11), b = 10.7452(13), c = 5.7577(7) Å, V = 651.98(12) Å3 and Z = 4. The five strongest lines in the powder X-ray diffraction pattern are [ d obs in Å/( I)/ hkl]: 3.155/(100)/221; 1.956/(26)/042,402; 2.886/(22)/311,002; 1.713/(21)/223; 2.691/(17)/040. The crystal structure was solved from single-crystal X-ray diffraction data and refined to R 1 = 0.0371 on the basis of 200 unique reflections with F o > 4σ F. The structure is based on double [O2Pb3] chains of edge-sharing oxo-centered [OPb4] tetrahedra along c, between which are sited SeO3 triangles. The two independent Pb2+ atoms and the Se4+ atom have sterochemically active lone electron pairs.

  4. Reduced electron back-injection in Al2O3/AlOx/Al2O3/graphene charge-trap memory devices

    NASA Astrophysics Data System (ADS)

    Lee, Sejoon; Song, Emil B.; Min Kim, Sung; Lee, Youngmin; Seo, David H.; Seo, Sunae; Wang, Kang L.

    2012-12-01

    A graphene charge-trap memory is devised using a single-layer graphene channel with an Al2O3/AlOx/Al2O3 oxide stack, where the ion-bombarded AlOx layer is intentionally added to create an abundance of charge-trap sites. The low dielectric constant of AlOx compared to Al2O3 reduces the potential drop in the control oxide Al2O3 and suppresses the electron back-injection from the gate to the charge-storage layer, allowing the memory window of the device to be further extended. This shows that the usage of a lower dielectric constant in the charge-storage layer compared to that of the control oxide layer improves the memory performance for graphene charge-trap memories.

  5. Fatigue mechanism of textured Pb(Mg1/3Nb2/3)O3-PbTiO3 ceramics

    NASA Astrophysics Data System (ADS)

    Yan, Yongke; Zhou, Yuan; Gupta, Shashaank; Priya, Shashank

    2013-08-01

    Grain orientation, BaTiO3 heterogeneous template content, and electrode materials are expected to play an important role in controlling the polarization fatigue behavior of ⟨001⟩ textured Pb(Mg1/3Nb2/3)O3-PbTiO3 ceramics. A comparative analysis with randomly oriented ceramics showed that ⟨001⟩ grain orientation/texture exhibits improved fatigue characteristics due to the reduced switching activation energy and high domain mobility. The hypothesis was validated from the systematic characterization of polarization—electric field behavior and domain wall density. The defect accumulation at the grain boundary and clamping effect arising from the presence of BaTiO3 heterogeneous template in the final microstructure was found to be the main cause for polarization degradation in textured ceramic.

  6. Ferroelectric enhancement in heterostructured ZnO /BiFeO3-PbTiO3 film

    NASA Astrophysics Data System (ADS)

    Yu, Shengwen; Chen, Rui; Zhang, Guanjun; Cheng, Jinrong; Meng, Zhongyan

    2006-11-01

    The authors have prepared heterostructured ZnO /BiFeO3-PbTiO3 (BFO-PT) composite film and BFO-PT film on Pt /Ti/SiO2/Si substrates by pulsed-laser deposition. The structure and morphologies of the films were characterized by x-ray diffraction (XRD) and scanning electron microscope. XRD results show that both films are perovskite structured last with different orientations. The leakage current density in the ZnO /BFO-PT film was found to be nearly two orders of magnitude lower. This could be due to the introduced ZnO layer behaving as a Schottky barrier between the BFO-PT film and top electrodes. The dramatic ferroelectric enhancement in ZnO /BFO-PT film is mostly ascribed to the improved insulation.

  7. Broadband infrared luminescence from Li2O-Al2O3-ZnO-SiO2 glasses doped with Bi2O3.

    PubMed

    Peng, Mingying; Qiu, Jianrong; Chen, Danping; Meng, Xiangeng; Zhu, Congshan

    2005-09-05

    The broadband emission in the 1.2~1.6mum region from Li2O-Al2O3-ZnO-SiO2 ( LAZS ) glass codoped with 0.01mol.%Cr2O3 and 1.0mol.%Bi2O3 when pumped by the 808nm laser at room temperature is not initiated from Cr4+ ions, but from bismuth, which is remarkably different from the results reported by Batchelor et al. The broad ~1300nm emission from Bi2O3-containing LAZS glasses possesses a FWHM ( Full Width at Half Maximum ) more than 250nm and a fluorescent lifetime longer than 500mus when excited by the 808nm laser. These glasses might have the potential applications in the broadly tunable lasers and the broadband fiber amplifiers.

  8. Luminescence properties of Y2O3:Bi3+, Yb3+ co-doped phosphor for application in solar cells

    NASA Astrophysics Data System (ADS)

    Lee, E.; Kroon, R. E.; Terblans, J. J.; Swart, H. C.

    2018-04-01

    Bismuth (Bi3+) and ytterbium (Yb3+) co-doped yttrium oxide (Y2O3) phosphor powder was successfully synthesised using the co-precipitation technique. The X-ray diffraction (XRD) patterns confirmed that a single phase cubic structure with a Ia-3 space group was formed. The visible emission confirmed the two symmetry sites, C2 and S6, found in the Y2O3 host material and revealed that Bi3+ ions preferred the S6 site as seen the stronger emission intensity. The near-infrared (NIR) emission of Yb3+ increased significantly by the presence of the Bi3+ ions when compared to the singly doped Y2O3:Yb3+ phosphor with the same Yb3+ concentration. An increase in the NIR emission intensity was also observed by simply increasing the Yb3+ concentration in the Y2O3:Bi3+, Yb3+ phosphor material where the intensity increased up to x = 5.0 mol% of Yb3+ before decreasing due to concentration quenching.

  9. Deriving ICD-10 Codes for Patient Safety Indicators for Large-scale Surveillance Using Administrative Hospital Data.

    PubMed

    Southern, Danielle A; Burnand, Bernard; Droesler, Saskia E; Flemons, Ward; Forster, Alan J; Gurevich, Yana; Harrison, James; Quan, Hude; Pincus, Harold A; Romano, Patrick S; Sundararajan, Vijaya; Kostanjsek, Nenad; Ghali, William A

    2017-03-01

    Existing administrative data patient safety indicators (PSIs) have been limited by uncertainty around the timing of onset of included diagnoses. We undertook de novo PSI development through a data-driven approach that drew upon "diagnosis timing" information available in some countries' administrative hospital data. Administrative database analysis and modified Delphi rating process. All hospitalized adults in Canada in 2009. We queried all hospitalizations for ICD-10-CA diagnosis codes arising during hospital stay. We then undertook a modified Delphi panel process to rate the extent to which each of the identified diagnoses has a potential link to suboptimal quality of care. We grouped the identified quality/safety-related diagnoses into relevant clinical categories. Lastly, we queried Alberta hospital discharge data to assess the frequency of the newly defined PSI events. Among 2,416,413 national hospitalizations, we found 2590 unique ICD-10-CA codes flagged as having arisen after admission. Seven panelists evaluated these in a 2-round review process, and identified a listing of 640 ICD-10-CA diagnosis codes judged to be linked to suboptimal quality of care and thus appropriate for inclusion in PSIs. These were then grouped by patient safety experts into 18 clinically relevant PSI categories. We then analyzed data on 2,381,652 Alberta hospital discharges from 2005 through 2012, and found that 134,299 (5.2%) hospitalizations had at least 1 PSI diagnosis. The resulting work creates a foundation for a new set of PSIs for routine large-scale surveillance of hospital and health system performance.

  10. Issues in Developing a Surveillance Case Definition for Nonfatal Suicide Attempt and Intentional Self-harm Using International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM) Coded Data.

    PubMed

    Hedegaard, Holly; Schoenbaum, Michael; Claassen, Cynthia; Crosby, Alex; Holland, Kristin; Proescholdbell, Scott

    2018-02-01

    Suicide and intentional self-harm are among the leading causes of death in the United States. To study this public health issue, epidemiologists and researchers often analyze data coded using the International Classification of Diseases (ICD). Prior to October 1, 2015, health care organizations and providers used the clinical modification of the Ninth Revision of ICD (ICD-9-CM) to report medical information in electronic claims data. The transition in October 2015 to use of the clinical modification of the Tenth Revision of ICD (ICD-10-CM) resulted in the need to update methods and selection criteria previously developed for ICD-9-CM coded data. This report provides guidance on the use of ICD-10-CM codes to identify cases of nonfatal suicide attempts and intentional self-harm in ICD-10-CM coded data sets. ICD-10-CM codes for nonfatal suicide attempts and intentional self-harm include: X71-X83, intentional self-harm due to drowning and submersion, firearms, explosive or thermal material, sharp or blunt objects, jumping from a high place, jumping or lying in front of a moving object, crashing of motor vehicle, and other specified means; T36-T50 with a 6th character of 2 (except for T36.9, T37.9, T39.9, T41.4, T42.7, T43.9, T45.9, T47.9, and T49.9, which are included if the 5th character is 2), intentional self-harm due to drug poisoning (overdose); T51-T65 with a 6th character of 2 (except for T51.9, T52.9, T53.9, T54.9, T56.9, T57.9, T58.0, T58.1, T58.9, T59.9, T60.9, T61.0, T61.1, T61.9, T62.9, T63.9, T64.0, T64.8, and T65.9, which are included if the 5th character is 2), intentional self-harm due to toxic effects of nonmedicinal substances; T71 with a 6th character of 2, intentional self-harm due to asphyxiation, suffocation, strangulation; and T14.91, Suicide attempt. Issues to consider when selecting records for nonfatal suicide attempts and intentional self-harm from ICD-10-CM coded administrative data sets are also discussed. All material appearing in this

  11. Interface ferromagnetism in oxide superlattices of CaMnO3/CaRuO3

    NASA Astrophysics Data System (ADS)

    Takahashi, K. S.; Kawasaki, M.; Tokura, Y.

    2001-08-01

    Oxide superlattices composed of antiferromagnetic insulator layers of CaMnO3 (10 unit cells) and paramagnetic metal layers of CaRuO3 (N unit cells) were fabricated on LaAlO3 substrates by pulsed-laser deposition. All the superlattices show ferromagnetic transitions at an almost identical temperature (TC˜95 K) and negative magnetoresistance below TC. Each magnetization and magnetoconductance of the whole superlattice at 5 K is constant and independent of CaRuO3 layer thickness when normalized by the number of the interfaces between CaMnO3 and CaRuO3. These results indicate that the ferromagnetism shows up only at the interface and is responsible for the magnetoresistance.

  12. A DFT+U study of A-site and B-site substitution in BaFeO3-δ.

    PubMed

    Baiyee, Zarah Medina; Chen, Chi; Ciucci, Francesco

    2015-09-28

    BaFeO3-δ (BFO)-based perovskites have emerged as cheap and effective oxygen electrocatalysts for oxygen reduction reaction at high temperatures. The BFO cubic phase facilitates a high oxygen deficiency and is commonly stabilised by partial substitution. Understanding the electronic mechanisms of substitution and oxygen deficiency is key to rational material design, and can be realised through DFT analysis. In this work an in-depth first principle DFT+U study is undertaken to determine site distinctive characteristics for 12.5%, Y, La and Ce substitutions in BFO. In particular, it is shown that B-site doped structures exhibit a lower energy cost for oxygen vacancy formation relative to A site doping and pristine BFO. This is attributed to the stabilisation of holes in the oxygen sub-lattice and increased covalency of the Fe-O bonds of the FeO6 octahedra in B-site-substituted BFO. Charge analysis shows that A-site substitution amounts to donor doping and consequently impedes the accommodation of other donors (i.e. oxygen vacancies). However, A-site substitution may also exhibit a higher electronic conductivity due to less lattice distortion for oxygen deficiency compared to B-site doped structures. Furthermore, analysis of the local structural effects provides physical insight into stoichiometric expansions observed for this material.

  13. Processing of Piezoelectric (Li,Na,K)NbO3 Porous Ceramics and (Li,Na,K)NbO3/KNbO3 Composites

    NASA Astrophysics Data System (ADS)

    Kakimoto, Ken-ichi; Imura, Tomoya; Fukui, Yasuchika; Kuno, Masami; Yamagiwa, Katsuya; Mitsuoka, Takeshi; Ohbayashi, Kazushige

    2007-10-01

    Porous Li0.06(Na0.5K0.5)0.94NbO3 (LNKN-6) ceramics with different pore volumes have been prepared using preceramic powder and phenol resin fiber (KynolTM) as a pore former. It was confirmed that the porous ceramics synthesized by the “two-stage firing method” suppressed the loss of alkali elements from the porous body during heat treatment. The porous LNKN-6 ceramics were then converted to LNKN-6/KNbO3 composites through soaking and heat treatment using a sol-gel precursor source composed of KNbO3 to form 3-3-type composites. The microstructure, dielectric, and piezoelectric properties of the porous LNKN-6 ceramics and LNKN-6/KNbO3 composites were characterized and compared. The LNKN-6/KNbO3 composites had a hollow structure whose pores in the region near the surface were filled and coated with KNbO3 precipitates; however, a large amount of residual air was trapped in the pores inside the composites. As a result, the LNKN-6/KNbO3 composites fabricated using 30 vol % KynolTM showed an enhanced piezoelectric voltage output coefficient (g33) of 63.0× 10-3 V\\cdotm/N, compared with monolithic LNKN-6 ceramics having a g33 of 30.2× 10-3 V\\cdotm/N.

  14. 78 FR 11889 - Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-20

    ... of the meeting announcement should read as follows: Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee. The first sentence of the notice should read as follows: National Center for Health Statistics (NCHS), Classifications and Public Health Data Standards Staff announces the...

  15. 2DEGs at Perovskite Interfaces between KTaO3 or KNbO3 and Stannates

    PubMed Central

    Fan, Xiaofeng; Zheng, Weitao; Chen, Xin; Singh, David J.

    2014-01-01

    We report density functional studies of electron rich interfaces between KTaO3 or KNbO3 and CaSnO3 or ZnSnO3 and in particular the nature of the interfacial electron gasses that can be formed. We find that depending on the details these may occur on either the transition metal or stannate sides of the interface and in the later case can be shifted away from the interface by ferroelectricity. We also present calculations for bulk KNbO3, KTaO3, CaSnO3, BaSnO3 and ZnSnO3, showing the different transport and optical properties that may be expected on the two sides of such interfaces. The results suggest that these interfaces may display a wide range of behaviors depending on conditions, and in particular the interplay with ferroelectricity suggests that electrical control of these properties may be possible. PMID:24626191

  16. Lanthanite-(Nd), Nd2(CO3)3·8H2O

    PubMed Central

    Morrison, Shaunna M.; Andrade, Marcelo B.; Wenz, Michelle D.; Domanik, Kenneth J.; Downs, Robert T.

    2013-01-01

    Lanthanite-(Nd), ideally Nd2(CO3)3·8H2O [dineodymium(III) tricarbonate octa­hydrate], is a member of the lanthanite mineral group characterized by the general formula REE 2(CO3)3·8H2O, where REE is a 10-coordinated rare earth element. Based on single-crystal X-ray diffraction of a natural sample from Mitsukoshi, Hizen-cho, Karatsu City, Saga Prefecture, Japan, this study presents the first structure determination of lanthanite-(Nd). Its structure is very similar to that of other members of the lanthanite group. It is composed of infinite sheets made up of corner- and edge-sharing of two NdO10-polyhedra (both with site symmetry ..2) and two carbonate triangles (site symmetries ..2 and 1) parallel to the ab plane, and stacked perpendicular to c. These layers are linked to one another only through hydrogen bonding involving the water mol­ecules. PMID:23476479

  17. Co3O4-x-Carbon@Fe2-yCoyO3 Heterostructural Hollow Polyhedrons for the Oxygen Evolution Reaction.

    PubMed

    Xu, Wangwang; Xie, Weiwei; Wang, Ying

    2017-08-30

    Hollow heterostructured nanomaterials have received tremendous interest in new-generation electrocatalyst applications. However, the design and fabrication of such materials remain a significant challenge. In this work, we present Co 3 O 4-x -carbon@Fe 2-y Co y O 3 heterostructural hollow polyhedrons that have been fabricated by facile thermal treatment followed by solution-phase growth for application as efficient oxygen evolution reaction (OER) electrocatalysts. Starting from a single ZIF-67 hollow polyhedron, a novel complex structured composite material constructed from Co 3 O 4-x nanocrystallite-embedded carbon matrix embedded with Fe 2-y Co y O 3 nanowires was successfully prepared. The Co 3 O 4-x nanocrystallite with oxygen vacancies provides both heterogeneous nucleation sites and growth platform for Fe 2-y Co y O 3 nanowires. The resultant heterostructure combines the advantages of Fe 2-y Co y O 3 nanowires with the large surface area and surface defects of Co 3 O 4-x nanocrystallite, resulting in improved electrocatalytic activity and electrical conductivity. As a result, such novel heterostructured OER electrocatalysts exhibit much lower onset potential (1.52 V) and higher current density (70 mA/cm 2 at 1.7 V) than Co 3 O 4-x -carbon hollow polyhedrons (onset 1.55 V, 35 mA/cm 2 at 1.7 V) and pure Co 3 O 4 hollow polyhedrons (onset 1.62 V, 5 mA/cm 2 at 1.7 V). Furthermore, the design and synthesis of metal-organic framework (MOF)-derived nanomaterials in this work offer new opportunities for developing novel and efficient electrocatalysts in electrochemical devices.

  18. Ferromagnetic CaRuO3

    PubMed Central

    Tripathi, Shivendra; Rana, Rakesh; Kumar, Sanjay; Pandey, Parul; Singh, R. S.; Rana, D. S.

    2014-01-01

    The non-magnetic and non-Fermi-liquid CaRuO3 is the iso-structural analog of the ferromagnetic (FM) and Fermi-liquid SrRuO3. We show that an FM order in the orthorhombic CaRuO3 can be established by the means of tensile epitaxial strain. The structural and magnetic property correlations in the CaRuO3 films formed on SrTiO3 (100) substrate establish a scaling relation between the FM moment and the tensile strain. The strain dependent crossover from non-magnetic to FM CaRuO3 was observed to be associated with switching of non-Fermi liquid to Fermi-liquid behavior. The intrinsic nature of this strain-induced FM order manifests in the Hall resistivity too; the anomalous Hall component realizes in FM tensile-strained CaRuO3 films on SrTiO3 (100) whereas the non-magnetic compressive-strained films on LaAlO3 (100) exhibit only the ordinary Hall effect. These observations of an elusive FM order are consistent with the theoretical predictions of scaling of the tensile epitaxial strain and the magnetic order in tensile CaRuO3. We further establish that the tensile strain is more efficient than the chemical route to induce FM order in CaRuO3. PMID:24464302

  19. Accuracy of the new ICD-9-CM code for "drip-and-ship" thrombolytic treatment in patients with ischemic stroke.

    PubMed

    Tonarelli, Silvina B; Tibbs, Michael; Vazquez, Gabriela; Lakshminarayan, Kamakshi; Rodriguez, Gustavo J; Qureshi, Adnan I

    2012-02-01

    A new International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis code, V45.88, was approved by the Centers for Medicare and Medicaid Services (CMS) on October 1, 2008. This code identifies patients in whom intravenous (IV) recombinant tissue plasminogen activator (rt-PA) is initiated in one hospital's emergency department, followed by transfer within 24 hours to a comprehensive stroke center, a paradigm commonly referred to as "drip-and-ship." This study assessed the use and accuracy of the new V45.88 code for identifying ischemic stroke patients who meet the criteria for drip-and-ship at 2 advanced certified primary stroke centers. Consecutive patients over a 12-month period were identified by primary ICD-9-CM diagnosis codes related to ischemic stroke. The accuracy of V45.88 code utilization using administrative data provided by Health Information Management Services was assessed through a comparison with data collected in prospective stroke registries maintained at each hospital by a trained abstractor. Out of a total of 428 patients discharged from both hospitals with a diagnosis of ischemic stroke, 37 patients were given ICD-9-CM code V45.88. The internally validated data from the prospective stroke database demonstrated that a total of 40 patients met the criteria for drip-and-ship. A concurrent comparison found that 92% (sensitivity) of the patients treated with drip-and-ship were coded with V45.88. None of the non-drip-and-ship stroke cases received the V45.88 code (100% specificity). The new ICD-9-CM code for drip-and-ship appears to have high specificity and sensitivity, allowing effective data collection by the CMS. Copyright © 2012 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. PREPARATION AND ELECTRICAL PROPERTIES OF BiFeO3/La0.7Sr0.3MnO3 MULTILAYERS

    NASA Astrophysics Data System (ADS)

    Zhu, Huiwen; Wang, Shunli; Li, Xiaoyun

    2013-07-01

    (La0.7Sr0.3MnO3 12 nm/BiFeO3 12 nm)10 was grown on SrTiO3 (001) substrate using rf magnetron sputtering. The structure analysis indicated that BiFeO3/La0.7Sr0.3MnO3 multilayers were highly (001)-oriented. Compared with bottom La0.7Sr0.3MnO3 electrode, the top La0.7Sr0.3MnO3 electrode displayed a rougher surface. The electric transport characteristics of the sample were investigated mainly at low temperature, and it was found that the sample exhibited resistance-temperature curves similar to those of La0.7Sr0.3MnO3 with the exception of an upturn at lower temperature region. Furthermore, a nonlinear I-V curve, which is characteristic of a tunneling conduction mechanism, was observed at 50 K. At higher temperature, the I-V curves were found to be diode-like. When the temperature was further increased to 300 K, the sample showed a space charge limited conduction (SCLC) characteristic.

  1. Polarization Rotation in Ferroelectric Tricolor PbTiO3/SrTiO3/PbZr0.2Ti0.8O3 Superlattices.

    PubMed

    Lemée, Nathalie; Infante, Ingrid C; Hubault, Cécile; Boulle, Alexandre; Blanc, Nils; Boudet, Nathalie; Demange, Valérie; Karkut, Michael G

    2015-09-16

    In ferroelectric thin films, controlling the orientation of the polarization is a key element to controlling their physical properties. We use laboratory and synchrotron X-ray diffraction to investigate ferroelectric bicolor PbTiO3/PbZr0.2Ti0.8O3 and tricolor PbTiO3/SrTiO3/PbZr0.2Ti0.8O3 superlattices and to study the role of the SrTiO3 layers on the domain structure. In the tricolor superlattices, we demonstrate the existence of 180° ferroelectric stripe nanodomains, induced by the depolarization field produced by the SrTiO3 layers. Each ultrathin SrTiO3 layer modifies the electrostatic boundary conditions between the ferroelectric layers compared to the corresponding bicolor structures, leading to the suppression of the a/c polydomain states. Combined with the electrostatic effect, the tensile strain induced by PbZr0.2Ti0.8O3 in the PbTiO3 layers leads to polarization rotation in the system as evidenced by grazing incidence X-ray measurements. This polarization rotation is associated with the monoclinic Mc phase as revealed by the splitting of the (HHL) and (H0L) reciprocal lattice points. This work demonstrates that the tricolor paraelectric/ferroelectric superlattices constitute a tunable system to investigate the concomitant effects of strains and depolarizing fields. Our studies provide a pathway to stabilize a monoclinic symmetry in ferroelectric layers, which is of particular interest for the enhancement of the piezoelectric properties.

  2. Lower tropospheric distributions of O3 and aerosol over Raoyang, a rural site in the North China Plain

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Xu, Xiaobin; Jia, Shihui; Ma, Ruisheng; Ran, Liang; Deng, Zhaoze; Lin, Weili; Wang, Ying; Ma, Zhiqiang

    2017-03-01

    The North China Plain (NCP) has become one of the most polluted regions in China, with the rapidly increasing economic growth in the past decades. High concentrations of ambient O3 and aerosol have been observed at urban as well as rural sites in the NCP. Most of the in situ observations of air pollutants have been conducted near the ground so that current knowledge about the vertical distributions of tropospheric O3 and aerosol over the NCP region is still limited. In this study, vertical profiles of O3 and size-resolved aerosol concentrations below 2.5 km were measured in summer 2014 over a rural site in the NCP, using an unmanned aerial vehicle (UAV) equipped with miniature analyzers. In addition, vertical profiles of aerosol scattering property in the lower troposphere and vertical profiles of O3 below 1 km were also observed at the site using a lidar and tethered balloon, respectively. The depths of the mixed layer and residual layer were determined according to the vertical gradients of lidar particle extinction and aerosol number concentration. Average O3 and size-resolved aerosol number concentration in both the mixed and residual layer were obtained from the data observed in seven UAV flights. The results show that during most of the flights the O3 levels above the top of mixed layer were higher than those below. Such a positive gradient in the vertical distribution of O3 makes the residual layer an important source of O3 in the mixed layer, particularly during the morning when the top of mixed layer is rapidly elevated. In contrast to O3, aerosol number concentration was normally higher in the mixed layer than in the residual layer, particularly in the early morning. Aerosol particles were overwhelmingly distributed in the size range < 1 µm, showing slight differences between the mixed and residual layers. Our measurements confirm that the lower troposphere over the rural area of the NCP is largely impacted by anthropogenic pollutants locally emitted or

  3. [Influences of R2O-Al2O3-B2O3-SiO2 system glass and superfine alpha-Al2O3 on the sintering and phase transition of hydroxyapatite ceramics].

    PubMed

    Wang, Zhiqiang; Chen, Xiaoxu; Cai, Yingji; Lü, Bingling

    2003-06-01

    The effects of R2O-Al2O3-B2O3-SiO2 system glass and superfine alpha-Al2O3 on the sintering and phase transition of hydroxyapatite (HAP) ceramics were assessed. The results showed that alpha-Al2O3 impeded the sintering of HAP and raised the sintering temperature. When glass and alpha-Al2O3 were used together to reinforce HAP ceramics, better results could be obtained; the bending strength of multiphase HAP ceramics approached 106 MPa when 10% (wt) alpha-Al2O3 and 20%(wt) glass were used and sintered at 1200 for 1 h.

  4. Material properties of perovskites in the quasi-ternary system LaFeO 3–LaCoO 3–LaNiO 3

    DOE PAGES

    Tietz, F.; Arul Raj, I.; Ma, Q.; ...

    2016-02-02

    We present an overview on the variation of electrical conductivity, oxygen permeation, oxygen surface exchange and thermal expansion coefficient as a function of the composition of perovskites in the quasi-ternary system LaFeO 3–LaCoO 3–LaNiO 3. Powders of thirteen nominal perovskite compositions were synthesized under identical conditions by the Pechini method. The powder X-ray diffraction data of two series, namely La(Ni 0.5Fe 0.5) 1-xCo xO 3 and LaNi 0.5- xFe xCo 0.5O 3, are presented after the powders had been sintered at 1100 C for 6 h in air. The measurements revealed a rhombohedral structure for all compositions except LaNi 0.5Femore » 0.5O 3 for which 60% rhombohedral and 40% orthorhombic phase was found. Moreover, the maximum DC electrical conductivity value of the perovskites at 800 C was 1229 S cm-1 for the composition LaCoO 3 and the minimum was 91 S cm-1 for the composition LaCo 0.5Fe 0.5O 3. The oxygen permeation of samples with promising conductivities at 800 C was one order of magnitude lower than that of La 0.6Sr 0.4Co 0.8Fe 0.2O 3 (LSCF). The highest value of 0.017 ml cm -2 min-1 at 950 C was obtained with LaNi 0.5Co 0.5O 3. The coefficients of thermal expansion varied in the range of 13.2 x 10 -6 K -1 and 21.9 x 10 -6 K -1 for LaNi 0.5Fe 0.5O 3 and LaCoO 3, respectively. 57Fe M ssbauer spectroscopy was used as probe for the oxidation states, local environment and magnetic properties of iron ions as a function of chemical composition. Ultimately, the substitution had a great influence on the chemical properties of the materials.« less

  5. Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: a substudy of the ECOST trial.

    PubMed

    Guédon-Moreau, Laurence; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Brigadeau, François; Boulé, Stéphane; Blangy, Hugues; Lacroix, Dominique; Clémenty, Jacques; Sadoul, Nicolas; Kacet, Salem

    2014-07-01

    Inappropriate shocks remain a highly challenging complication of implantable cardioverter defibrillators (ICD). We examined whether automatic wireless remote monitoring (RM) of ICD, by providing early notifications of triggering events, lowers the incidence of inappropriate shocks. We studied 433 patients randomly assigned to RM (n = 221; active group) versus ambulatory follow-up (n = 212; control group). Patients in the active group were seen in the ambulatory department once a year, unless RM reported an event requiring an earlier ambulatory visit. Patients in the control group were seen in the ambulatory department every 6 months. The occurrence of first and further inappropriate shocks, and their causes in each group were compared. The characteristics of the study groups, including pharmaceutical regimens, were similar. Over a follow-up of 27 months, 5.0% of patients in the active group received ≥1 inappropriate shocks versus 10.4% in the control group (P = 0.03). A total of 28 inappropriate shocks were delivered in the active versus 283 in the control group. Shocks were triggered by supraventricular tachyarrhythmias (SVTA) in 48.5%, noise oversensing in 21.2%, T wave oversensing in 15.2%, and lead dysfunction in 15.2% of patients. The numbers of inappropriate shocks delivered per patient, triggered by SVTA and by lead dysfunction, were 74% and 98% lower, respectively, in the active than in the control group. RM was highly effective in the long-term prevention of inappropriate ICD shocks. © 2014 Wiley Periodicals, Inc.

  6. Thermodynamic Assessment of the Y2o3-yb2o3-zro2 System

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Liu, Zi-Kui; Kaufman, Larry; Zhang, Fan

    2002-01-01

    Yttria-zirconia (Y2O3-ZrO2) is the most widely used of the rare earth oxide-zirconia systems. There are numerous experimental studies of the phase boundaries in this system. In this paper, we assess these data and derive parameters for the solution models in this system. There is current interest in other rare earth oxide-zirconia systems as well as systems with several rare earth oxides and zirconia, which may offer improved properties over the Y2O3-ZrO2 system. For this reason, we also assess the ytterbia-zirconia (Yb2O3-ZrO2) and Y2O3-Yb2O3-ZrO2 system.

  7. Interfacial magnetism in CaRuO3/CaMnO3 superlattices grown on (001) SrTiO3

    NASA Astrophysics Data System (ADS)

    He, C.; Zhai, X.; Mehta, V. V.; Wong, F. J.; Suzuki, Y.

    2011-04-01

    We have studied epitaxially grown superlattices of CaRuO3/CaMnO3 as well as an alloy film of CaMn0.5Ru0.5O3 on (001) SrTiO3 substrates. In contrast to previous experiments, we have studied CRO/CMO superlattices with a constant CRO thickness and variable CMO thickness. All superlattices exhibit Curie temperatures (TC) of 110 K. The saturated magnetization per interfacial Mn cation has been found to be 1.1 μB/Mn ion. The TC's of the superlattices are much lower than the TC of the alloy film while the saturated magnetization values are larger than that of the alloy film. These observations suggest that interdiffusion alone cannot account for ferromagnetism in the superlattices and that double exchange induced FM must play a role at the interfaces.

  8. Magnetism from Fe2O3 nanoparticles embedded in amorphous SiO2 matrix

    NASA Astrophysics Data System (ADS)

    Sendil Kumar, A.; Bhatnagar, Anil K.

    2018-02-01

    Fe2O3 nanoparticles are embedded in amorphous SiO2 matrix by coprecipitation method with varying concentrations. Conditions are optimized to get almost monodispersed Fe2O3 nanoparticles with high chemical stability. Microstructure of synthesized nanoparticles is well characterized and found that Fe2O3 is in nanocrystalline form and embedded uniformly in amorphous SiO2 matrix. Enhanced surface reactivity is found for nanoparticles which influences physical properties of the SiO2 supported Fe2O3 system due to adsorption. In oxide nanoparticles, significant number of defect sites at the surface is expected but when supported medium such as SiO2 it reduces this defect concentration. Field- and temperature-dependent magnetisation studies on these samples show superparamagnetic behaviour. Superparamagnetic behaviour is seen in all the concentration systems but the coercivity observed in the lower concentration systems is found to be anomalous compared to that of higher concentrations. The observed magnetic behaviour comes from either unsaturated bond existing due to the absence of anions at the surface of nanoparticles or reconstruction of atomic orbitals taking place at interface of Fe2O3-SiO2 system.

  9. The effect of cost construction based on either DRG or ICD-9 codes or risk group stratification on the resulting cost-effectiveness ratios.

    PubMed

    Chumney, Elinor C G; Biddle, Andrea K; Simpson, Kit N; Weinberger, Morris; Magruder, Kathryn M; Zelman, William N

    2004-01-01

    As cost-effectiveness analyses (CEAs) are increasingly used to inform policy decisions, there is a need for more information on how different cost determination methods affect cost estimates and the degree to which the resulting cost-effectiveness ratios (CERs) may be affected. The lack of specificity of diagnosis-related groups (DRGs) could mean that they are ill-suited for costing applications in CEAs. Yet, the implications of using International Classification of Diseases-9th edition (ICD-9) codes or a form of disease-specific risk group stratification instead of DRGs has yet to be clearly documented. To demonstrate the implications of different disease coding mechanisms on costs and the magnitude of error that could be introduced in head-to-head comparisons of resulting CERs. We based our analyses on a previously published Markov model for HIV/AIDS therapies. We used the Healthcare Cost and Utilisation Project Nationwide Inpatient Sample (HCUP-NIS) data release 6, which contains all-payer data on hospital inpatient stays from selected states. We added costs for the mean number of hospitalisations, derived from analyses based on either DRG or ICD-9 codes or risk group stratification cost weights, to the standard outpatient and prescription drug costs to yield an estimate of total charges for each AIDS-defining illness (ADI). Finally, we estimated the Markov model three times with the appropriate ADI cost weights to obtain CERs specific to the use of either DRG or ICD-9 codes or risk group. Contrary to expectations, we found that the choice of coding/grouping assumptions that are disease-specific by either DRG codes, ICD-9 codes or risk group resulted in very similar CER estimates for highly active antiretroviral therapy. The large variations in the specific ADI cost weights across the three different coding approaches was especially interesting. However, because no one approach produced consistently higher estimates than the others, the Markov model's weighted

  10. Homologous compounds of type ARO3(ZnO)m in the system Ga-Sn-Zn-O

    NASA Astrophysics Data System (ADS)

    Eichhorn, Simon; Schmid, Herbert; Assenmacher, Wilfried; Mader, Werner

    2017-02-01

    Several members of hitherto unknown homologous compounds [Sn0.5Zn0.5]GaO3(ZnO)m (m=3-7) of the general formula ARO3(ZnO)m were prepared by solid state methods from the binary oxides in sealed Pt-tubes. UV-vis measurements confirm these compounds to be transparent oxides with an optical band gap in the UV region with Eg≈3 eV. Rietveld refinements on powder samples of [Sn0.5Zn0.5]GaO3(ZnO)m proved the compounds to be isostructural with InGaO3(ZnO)m, where In3+ on octahedral sites is replaced statistically by Sn4+ and Zn2+ in equal amounts preserving an average charge of 3+. Additionally, the structure of [Sn0.5Zn0.5]GaO3(ZnO)3 has been determined from flux-grown single crystals by X-ray diffraction (R 3 ̅ m , Z=3, a=3.2387(7) Å, c=41.78(1) Å, 19 parameters, 201 independent reflections, R1=0.047, wR2=0.074). The compound [Sn0.5Zn0.5]GaO3(ZnO)3 is isostructural with InGaO3(ZnO)3. [Sn0.5Zn0.5]GaO3(ZnO)3 was furthermore analyzed by High Angle Annular Dark Field (HAADF) scanning TEM and EELS spectroscopic imaging, supporting the structure model derived from X-ray diffraction data.

  11. Magnetostriction of Hexagonal HoMnO3 and YMnO3 Single Crystals

    NASA Astrophysics Data System (ADS)

    Pavlovskii, N. S.; Dubrovskii, A. A.; Nikitin, S. E.; Semenov, S. V.; Terent'ev, K. Yu.; Shaikhutdinov, K. A.

    2018-03-01

    We report on the magnetostriction of hexagonal HoMnO3 and YMnO3 single crystals in a wide range of applied magnetic fields (up to H = 14 T) at all possible combinations of the mutual orientations of magnetic field H and magnetostriction Δ L/L. The measured Δ L/L( H, T) data agree well with the magnetic phase diagram of the HoMnO3 single crystal reported previously by other authors. It is shown that the nonmonotonic behavior of magnetostriction of the HoMnO3 crystal is caused by the Ho3+ ion; the magnetic moment of the Mn3+ ion parallel to the hexagonal crystal axis. The anomalies established from the magnetostriction measurements of HoMnO3 are consistent with the phase diagram of these compounds. For the isostructural YMnO3 single crystal with a nonmagnetic rare-earth ion, the Δ L/L( H, T) dependences are described well by a conventional quadratic law in a wide temperature range (4-100 K). In addition, the magnetostriction effect is qualitatively estimated with regard to the effect of the crystal electric field on the holmium ion.

  12. A comparative study of CeO2-Al2O3 support prepared with different methods and its application on MoO3/CeO2-Al2O3 catalyst for sulfur-resistant methanation

    NASA Astrophysics Data System (ADS)

    Jiang, Minhong; Wang, Baowei; Yao, Yuqin; Li, Zhenhua; Ma, Xinbin; Qin, Shaodong; Sun, Qi

    2013-11-01

    The CeO2-Al2O3 supports prepared with impregnation (IM), deposition precipitation (DP), and solution combustion (SC) methods for MoO3/CeO2-Al2O3 catalyst were investigated in the sulfur-resistant methanation. The supports and catalysts were characterized by N2-physisorption, transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman spectroscopy (RS), and temperature-programmed reduction (TPR). The N2-physisorption results indicated that the DP method was favorable for obtaining better textural properties. The TEM and RS results suggested that there is a CeO2 layer on the surface of the support prepared with DP method. This CeO2 layer not only prevented the interaction between MoO3 and γ-Al2O3 to form Al2(MoO4)3 species, but also improved the dispersion of MoO3 in the catalyst. Accordingly, the catalysts whose supports were prepared with DP method exhibited the best catalytic activity. The catalysts whose supports were prepared with SC method had the worst catalytic activity. This was caused by the formation of Al2(MoO4)3 and crystalline MoO3. Additionally, the CeO2 layer resulted in the instability of catalysts in reaction process. The increasing of calcination temperature of supports reduced the catalytic activity of all catalysts. The decrease extent of the catalysts whose supports were prepared with DP method was the lowest as the CeO2 layer prevented the interaction between MoO3 and γ-Al2O3.

  13. Structural Investigations of the MnO-Bi3O3-CdO Glass System by IR and Raman Spectroscopies

    NASA Astrophysics Data System (ADS)

    Ardelean, I.; Todor, Ioana; PǍŞCUŢǍ, P.

    Homogeneous glasses are formed in the MnO-Bi3O3-CdO system, up to 50 mol% MnO. For these glasses, IR and Raman spectral measurements are carried out in order to elucidate the local structure. We identify by IR spectroscopy both the structural units BiO3 and BiO6. The Raman investigation confirms the prevalence of BiO6 groups in the glass network for all concentrations. The number of these structural groups progressively increases with MnO content.

  14. Enhanced texture evolution and piezoelectric properties in CuO-doped Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 grain-oriented ceramics

    NASA Astrophysics Data System (ADS)

    Chang, Yunfei; Watson, Beecher; Fanton, Mark; Meyer, Richard J.; Messing, Gary L.

    2017-12-01

    In this work, both crystallographic texture and doping engineering strategies were integrated to develop relaxor-PbTiO3 (PT) based ternary ferroelectric ceramics with enhanced texture evolution and superior electromechanical properties. CuO-doped Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) piezoelectric ceramics with [001]c texture fraction ≥97% were synthesized by templated grain growth. The addition of CuO significantly promotes densification and oriented grain growth in the templated ceramics, leading to full texture development at dramatically reduced times and temperatures. Moreover, the CuO dopant remarkably enhances the piezoelectric properties of the textured ceramics while maintaining high phase transition temperatures and large coercive fields. Doping 0.125 wt. % CuO yields the electromechanical properties of d33 = 927 pC/N, d33* = 1510 pm/V, g33 = 43.2 × 10-3 Vm/N, Kp = 0.87, Ec=8.8 kV/cm, and tan δ = 1.3%, which are the best values reported so far in PIN-PMN-PT based ceramics. The high piezoelectric coefficient is mainly from the reversible piezoelectric response, with the irreversible contribution being on the order of 13.1%. We believe that this work not only facilitates closing the performance gap between ceramics and single crystals but also can expand relaxor-PT based piezoelectric application fields.

  15. Effect of the Molar Ratio of B2O3 to Bi2O3 in Al Paste with Bi2O3-B2O3-ZnO Glass on Screen Printed Contact Formation and Si Solar Cell Performance

    NASA Astrophysics Data System (ADS)

    Kim, Bit-Na; Kim, Hyeong Jun; Chang, Hyo Sik; Hong, Hyun Seon; Ryu, Sung-Soo; Lee, Heon

    2013-10-01

    In this study, eco-friendly Pb-free Bi2O3-B2O3-ZnO glass frits were chosen as an inorganic additive for the Al paste used in Si solar cells. The effects of the molar ratio of Bi2O3 to B2O3 in the glass composition on the electrical resistance of the Al electrode and on the cell performance were investigated. The results showed that as the molar ratio of Bi2O3 to B2O3 increased, the glass transition temperature and softening temperature decreased because of the reduced glass viscosity. In Al screen-printed Si solar cells, as the molar ratio of Bi2O3 to B2O3 increased, the sheet electrical resistance of the Al electrode decreased and the cell efficiency increased. The uniformity and thickness of the back-surface field was significantly influenced by the glass composition.

  16. Current understanding of structure-processing-property relationships in BaTiO 3-Bi( M)O 3 dielectrics

    DOE PAGES

    Beuerlein, Michaela A.; Kumar, Nitish; Usher, Tedi -Marie; ...

    2016-09-01

    Here, as part of a continued push for high permittivity dielectrics suitable for use at elevated operating temperatures and/or large electric fields, modifications of BaTiO 3 with Bi( M)O 3, where M represents a net-trivalent B-site occupied by one or more species, have received a great deal of recent attention. Materials in this composition family exhibit weakly coupled relaxor behavior that is not only remarkably stable at high temperatures and under large electric fields, but is also quite similar across various identities of M. Moderate levels of Bi content (as much as 50 mol%) appear to be crucial to themore » stability of the dielectric response. In addition, the presence of significant Bi reduces the processing temperatures required for densification and increases the required oxygen content in processing atmospheres relative to traditional X7R-type BaTiO 3-based dielectrics. Although detailed understanding of the structure–processing–property relationships in this class of materials is still in its infancy, this article reviews the current state of understanding of the mechanisms underlying the high and stable values of both relative permittivity and resistivity that are characteristic of BaTiO 3-Bi( M)O 3 dielectrics as well as the processing challenges and opportunities associated with these materials.« less

  17. Preliminary field trial of a putative research algorithm for diagnosing ICD-11 personality disorders in psychiatric patients: 2. Proposed trait domains.

    PubMed

    Kim, Youl-Ri; Tyrer, Peter; Lee, Hong-Seock; Kim, Sung-Gon; Hwang, Soon-Taek; Lee, Gi Young; Mulder, Roger

    2015-11-01

    This field trial examines the discriminant validity of five trait domains of the originally proposed research algorithm for diagnosing International Classification of Diseases (ICD)-11 personality disorders. This trial was carried out in South Korea where a total of 124 patients with personality disorder participated in the study. Participants were assessed using originally proposed monothetic trait domains of asocial-schizoid, antisocial-dissocial, anxious-dependent, emotionally unstable and anankastic-obsessional groups of the research algorithm in ICD-11. Their assessments were compared to those from the Personality Assessment Schedule interview, and the five-factor model (FFM). A total of 48.4% of patients were found to have pathology in two or more domains. In the discriminant analysis, 64.2% of the grouped cases of the originally proposed ICD-11 domains were correctly classified by the five domain categories using the Personality Assessment Schedule, with the highest accuracy in the anankastic-obsessional domain and the lowest accuracy in the emotionally unstable domain. In comparison, the asocial-schizoid, anxious-dependent and the emotionally unstable domains were moderately correlated with the FFM, whereas the anankastic-obsessional or antisocial-dissocial domains were not significantly correlated with the FFM. In this field trial, we demonstrated the limited discriminant and the convergent validities of the originally proposed trait domains of the research algorithm for diagnosing ICD-11 personality disorder. The results suggest that the anankastic, asocial and dissocial domains show good discrimination, whereas the anxious-dependent and emotionally unstable ones overlap too much and have been subsequently revised. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Thermoluminescence and optically stimulated luminescence properties of Dy3+-doped CaO-Al2O3-B2O3-based glasses

    NASA Astrophysics Data System (ADS)

    Yahaba, T.; Fujimoto, Y.; Yanagida, T.; Koshimizu, M.; Tanaka, H.; Saeki, K.; Asai, K.

    2017-02-01

    We developed Dy3+-doped CaO-Al2O3-B2O3 based glasses with Dy concentrations of 0.5, 1.0, and 2.0 mol% using a melt-quenching technique. The as-synthesized glasses were applicable as materials exhibiting thermoluminescence (TL) and optically stimulated luminescence (OSL). The optical and radiation response properties of the glasses were characterized. In the photoluminescence (PL) spectra, two emission bands due to the 4F9/2 → 6H15/2 and 4F9/2 → 6H13/2 transitions of Dy3+ were observed at 480 and 580 nm. In the OSL spectra, the emission band due to the 4F9/2 → 6H15/2 transition of Dy3+ was observed. Excellent TL and OSL responses were observed for dose ranges of 0.1-90 Gy. In addition, TL fading behavior was better than that of OSL in term of the long-time storage. These results indicate that the Dy3+-doped CaO-Al2O3-B2O3-based glasses are applicable as TL materials.

  19. The Study of Electrical Properties for Multilayer La2O3/Al2O3 Dielectric Stacks and LaAlO3 Dielectric Film Deposited by ALD.

    PubMed

    Feng, Xing-Yao; Liu, Hong-Xia; Wang, Xing; Zhao, Lu; Fei, Chen-Xi; Liu, He-Lei

    2017-12-01

    The capacitance and leakage current properties of multilayer La 2 O 3 /Al 2 O 3 dielectric stacks and LaAlO 3 dielectric film are investigated in this paper. A clear promotion of capacitance properties is observed for multilayer La 2 O 3 /Al 2 O 3 stacks after post-deposition annealing (PDA) at 800 °C compared with PDA at 600 °C, which indicated the recombination of defects and dangling bonds performs better at the high-k/Si substrate interface for a higher annealing temperature. For LaAlO 3 dielectric film, compared with multilayer La 2 O 3 /Al 2 O 3 dielectric stacks, a clear promotion of trapped charges density (N ot ) and a degradation of interface trap density (D it ) can be obtained simultaneously. In addition, a significant improvement about leakage current property is observed for LaAlO 3 dielectric film compared with multilayer La 2 O 3 /Al 2 O 3 stacks at the same annealing condition. We also noticed that a better breakdown behavior for multilayer La 2 O 3 /Al 2 O 3 stack is achieved after annealing at a higher temperature for its less defects.

  20. A new coding system for metabolic disorders demonstrates gaps in the international disease classifications ICD-10 and SNOMED-CT, which can be barriers to genotype-phenotype data sharing.

    PubMed

    Sollie, Annet; Sijmons, Rolf H; Lindhout, Dick; van der Ploeg, Ans T; Rubio Gozalbo, M Estela; Smit, G Peter A; Verheijen, Frans; Waterham, Hans R; van Weely, Sonja; Wijburg, Frits A; Wijburg, Rudolph; Visser, Gepke

    2013-07-01

    Data sharing is essential for a better understanding of genetic disorders. Good phenotype coding plays a key role in this process. Unfortunately, the two most widely used coding systems in medicine, ICD-10 and SNOMED-CT, lack information necessary for the detailed classification and annotation of rare and genetic disorders. This prevents the optimal registration of such patients in databases and thus data-sharing efforts. To improve care and to facilitate research for patients with metabolic disorders, we developed a new coding system for metabolic diseases with a dedicated group of clinical specialists. Next, we compared the resulting codes with those in ICD and SNOMED-CT. No matches were found in 76% of cases in ICD-10 and in 54% in SNOMED-CT. We conclude that there are sizable gaps in the SNOMED-CT and ICD coding systems for metabolic disorders. There may be similar gaps for other classes of rare and genetic disorders. We have demonstrated that expert groups can help in addressing such coding issues. Our coding system has been made available to the ICD and SNOMED-CT organizations as well as to the Orphanet and HPO organizations for further public application and updates will be published online (www.ddrmd.nl and www.cineas.org). © 2013 WILEY PERIODICALS, INC.

  1. Lead-Free KNbO3:xZnO Composite Ceramics.

    PubMed

    Lv, Xiang; Li, Zhuoyun; Wu, Jiagang; Xiao, Dingquan; Zhu, Jianguo

    2016-11-09

    It is a tough issue to develop dense and water resistant KNbO 3 ceramics due to high evaporation and hygroscopicity of K 2 O. Here, KNbO 3 :xZnO composite ceramics were used to successfully solve this problem, where ZnO particles were randomly distributed into a KNbO 3 matrix. The addition of ZnO hardly affects the phase structure of KNbO 3 , and moreover, the enhancement of electrical properties, thermal stability, and aging characteristics was observed in KNbO 3 :xZnO composite ceramics. The composites possessed the maximum d 33 of 120 ± 5 pC/N, which is superior to that of pure KNbO 3 (d 33 = 80 pC/N). More importantly, a strong water resistance and an aging-free characteristic were observed in KNbO 3 :0.4ZnO. This is the first time for KNbO 3 ceramics to simultaneously improve electrical properties and resolve the water-absorbing properties. We believe that these composite ceramics are promising for practical applications.

  2. The Phase Relations in the In 2O 3-Al 2ZnO 4-ZnO System at 1350°C

    NASA Astrophysics Data System (ADS)

    Nakamura, Masaki; Kimizuka, Noboru; Mohri, Takahiko; Isobe, Mitsumasa

    1993-08-01

    Phase relations in the In 2O 3-Al 2ZnO 4-ZnO system at 1350°C are determined by a classical quenching method. This system consists of In 2O 3, Al 2ZnO 4, ZnO, and homologous phases InAlO 3(ZnO) m ( m = 2, 3, …) having solid solutions with LuFeO 3(ZnO) m-type crystal structures. These solid solution ranges are as follows: In 1+ x1Al 1- x1O 3(ZnO) 2 ( x1 = 0.70)-In 1+ x2Al 1- x2O 3(ZnO) 2 ( x2 = 0.316-0.320), In 2O 3(ZnO) 3-In 1+ xAl 1- xO 3(ZnO) 3 ( x = 0.230), In 2O 3(ZnO) 4-In 1+ xAl 1- xO 3(ZnO) 4 ( x = 0.15-0.16), In 2O 3(ZnO) 5-In 1+ xAl 1- xO 3(ZnO) 5 ( x = 0.116-0.130), In 2O 3(ZnO) 6-In 1+ xAl 1- xO 3(ZnO) 6 ( x = 0.000-0.111), In 2O 3(ZnO) 7-In 1+ xAl 1- xO 3(ZnO) 7 ( x = 0.08), In 2O 3(ZnO) 8-In 1+ xAl 1- xO 3(ZnO) 8 ( x: undetermined), and In 2O 3(ZnO) m-InAlO 3(ZnO) m ( m = 9, 10, 11, 13, 15, 17, and 19). The space groups of these homologous phases belong to R3¯ m for m = odd or P6 3/ mmc for m = even. Their crystal structures, In 1+ xAl 1- xO 3(ZnO) m (0 < x < 1), consist of three kinds of layers: an InO 1.5 layer, an (In xAl 1- xZn)O 2.5 layer, and ZnO layers. A comparison of the phase relations in the In 2O 3- M2ZnO 4-ZnO systems ( M = Fe, Ga, or Al) is made and their characteristic features are discussed in terms of the ionic radii and site preferences of the M cations.

  3. Twin-induced phase transition from β-Ga2O3 to α-Ga2O3 in Ga2O3 thin films

    NASA Astrophysics Data System (ADS)

    Choi, Byeongdae; Allabergenov, Bunyod; Lyu, Hong-Kun; Lee, Seong Eui

    2018-06-01

    We deposited a 300-nm-thick Ga2O3 thin film on an amorphous SiO2/Si substrate via pulsed laser deposition. X-ray diffraction patterns revealed the formation of β-Ga2O3 phase at a substrate temperature of 700 °C. X-ray photoelectron spectra indicated that the degree of oxidation increased after annealing at 700 °C. Further annealings at higher temperatures led to a transition of the β-Ga2O3 phase to the α-Ga2O3 phase; this transition was caused by the twin structure formed during the crystallinity improvement process. In addition, we discuss the mechanism of the transition from the β phase to the α phase in the β-Ga2O3 thin films.

  4. Engineered Mott ground state in a LaTiO3+δ/LaNiO3 heterostructure

    NASA Astrophysics Data System (ADS)

    Cao, Yanwei; Liu, Xiaoran; Kareev, M.; Choudhury, D.; Middey, S.; Meyers, D.; Kim, J.-W.; Ryan, P. J.; Freeland, J. W.; Chakhalian, J.

    2016-01-01

    In pursuit of creating cuprate-like electronic and orbital structures, artificial heterostructures based on LaNiO3 have inspired a wealth of exciting experimental and theoretical results. However, to date there is a very limited experimental understanding of the electronic and orbital states emerging from interfacial charge transfer and their connections to the modified band structure at the interface. Towards this goal, we have synthesized a prototypical superlattice composed of a correlated metal LaNiO3 and a doped Mott insulator LaTiO3+δ, and investigated its electronic structure by resonant X-ray absorption spectroscopy combined with X-ray photoemission spectroscopy, electrical transport and theory calculations. The heterostructure exhibits interfacial charge transfer from Ti to Ni sites, giving rise to an insulating ground state with orbital polarization and eg orbital band splitting. Our findings demonstrate how the control over charge at the interface can be effectively used to create exotic electronic, orbital and spin states.

  5. Engineered Mott ground state in a LaTiO3+δ/LaNiO3 heterostructure

    PubMed Central

    Cao, Yanwei; Liu, Xiaoran; Kareev, M.; Choudhury, D.; Middey, S.; Meyers, D.; Kim, J.-W.; Ryan, P. J.; Freeland, J.W.; Chakhalian, J.

    2016-01-01

    In pursuit of creating cuprate-like electronic and orbital structures, artificial heterostructures based on LaNiO3 have inspired a wealth of exciting experimental and theoretical results. However, to date there is a very limited experimental understanding of the electronic and orbital states emerging from interfacial charge transfer and their connections to the modified band structure at the interface. Towards this goal, we have synthesized a prototypical superlattice composed of a correlated metal LaNiO3 and a doped Mott insulator LaTiO3+δ, and investigated its electronic structure by resonant X-ray absorption spectroscopy combined with X-ray photoemission spectroscopy, electrical transport and theory calculations. The heterostructure exhibits interfacial charge transfer from Ti to Ni sites, giving rise to an insulating ground state with orbital polarization and eg orbital band splitting. Our findings demonstrate how the control over charge at the interface can be effectively used to create exotic electronic, orbital and spin states. PMID:26791402

  6. Engineered Mott ground state in a LaTiO 3+δ/LaNiO 3 heterostructure

    DOE PAGES

    Cao, Yanwei; Liu, Xiaoran; Kareev, M.; ...

    2016-01-21

    In pursuit of creating cuprate-like electronic and orbital structures, artificial heterostructures based on LaNiO 3 have inspired a wealth of exciting experimental and theoretical results. However, to date there is a very limited experimental understanding of the electronic and orbital states emerging from interfacial charge transfer and their connections to the modified band structure at the interface. Towards this goal, we have synthesized a prototypical superlattice composed of a correlated metal LaNiO 3 and a doped Mott insulator LaTiO 3+δ, and investigated its electronic structure by resonant X-ray absorption spectroscopy combined with X-ray photoemission spectroscopy, electrical transport and theory calculations.more » The heterostructure exhibits interfacial charge transfer from Ti to Ni sites, giving rise to an insulating ground state with orbital polarization and e g orbital band splitting. Here, our findings demonstrate how the control over charge at the interface can be effectively used to create exotic electronic, orbital and spin states.« less

  7. Thermodynamic characterization of Ni3TeO6, Ni2Te3O8 and NiTe2O5

    NASA Astrophysics Data System (ADS)

    Dawar, Rimpi; Babu, R.; Ananthasivan, K.; Anthonysamy, S.

    2017-09-01

    Measurement of vapour pressure of TeO2(g) over the biphasic mixture Ni3TeO6 (s) + NiO(s) in the temperature range 1143-1272 K was carried out using transpiration-thermogravimetric technique (TTG). Gibbs energy of formation of Ni3TeO6 was obtained from the temperature dependence of vapour pressure of TeO2 (g) generated by the incongruent vapourisation reaction, Ni3TeO6 (s) → NiO(s) + TeO2 (g) + 1/2 O2 in the temperature range 1143-1272 K. An isoperibol type drop calorimeter was used to measure the enthalpy increments of Ni3TeO6, Ni2Te3O8 and NiTe2O5. Thermodynamic functions viz., heat capacity, entropy and Gibbs energy functions of these compounds were derived from the experimentally measured enthalpy increment values. Third-law analysis was carried out to ascertain absence of temperature dependent systematic errors in the measurement of vapour pressure of TeO2 (g). A value of -1265.1 ± 1.5 kJ mol-1 was obtained for Δ Hf,298K o (Ni3TeO6) using third-law analysis.

  8. Electromechanical behavior of [001]-textured Pb(Mg1/3Nb2/3)O3-PbTiO3 ceramics

    NASA Astrophysics Data System (ADS)

    Yan, Yongke; Wang, Yu. U.; Priya, Shashank

    2012-05-01

    [001]-textured Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) ceramics were synthesized by using templated grain growth method. Significantly high [001] texture degree corresponding to 0.98 Lotgering factor was achieved at 1 vol. % BaTiO3 template. Electromechanical properties for [001]-textured PMN-PT ceramics with 1 vol. % BaTiO3 were found to be d33 = 1000 pC/N, d31 = 371 pC/N, ɛr = 2591, and tanδ = ˜0.6%. Elastoelectric composite based modeling results showed that higher volume fraction of template reduces the overall dielectric constant and thus has adverse effect on the piezoelectric response. Clamping effect was modeled by deriving the changes in free energy as a function of applied electric field and microstructural boundary condition.

  9. Synthesis, structure, and characterization of two new bismuth(III) selenite/tellurite nitrates: [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) and [Bi(TeO{sub 3})](NO{sub 3})

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meng, Chang-Yu; Wei, Ming-Fang; Geng, Lei, E-mail: lgeng.cn@gmail.com

    Two new bismuth(III) selenite/tellurite nitrates, [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) and [Bi(TeO{sub 3})](NO{sub 3}), have been synthesized by conventional facile hydrothermal method at middle temperature 200 °C and characterized by single-crystal X-ray diffraction, powder diffraction, UV–vis–NIR optical absorption spectrum, infrared spectrum and thermal analylsis. Both [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) and [Bi(TeO3)](NO3) crystallize in the monoclinic centronsymmetric space group P2{sub 1}/c with a=9.9403(4) Å, b=9.6857(4) Å, c=10.6864(5) Å, β=93.1150(10)° for [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) and a=8.1489(3) Å, b=9.0663(4) Å, c=7.4729(3) Å, β=114.899(2)° for Bi(TeO3)(NO3), respectively. The two compounds, whose structures are composed of three different asymmetricmore » building units, exhibit two different types of structures. The structure of [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) features a three-dimensional (3D) bismuth(III) selenite cationic tunnel structure [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}] {sup 3}{sub ∞} with NO{sub 3}{sup −} anion group filling in the 1D tunnel along b axis. The structure of [Bi(TeO{sub 3})](NO{sub 3}) features 2D bismuth(III) tellurite [Bi(TeO{sub 3}){sub 2}]{sup 2}{sub ∞} layers separated by NO{sub 3}{sup −} anion groups. The results of optical diffuse-reflectance spectrum measurements and electronic structure calculations based on density functional theory methods show that the two compounds are wide band-gap semiconductors. - Graphical abstract: Two novel bismuth{sup III} selenite/tellurite nitrates [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) with 3D tunnel structure and [Bi(TeO{sub 3})](NO{sub 3}) with 2D layer structure have been firstly synthesized and characterized. Display Omitted - Highlights: • Two novel bismuth{sup III} nitrates [(Bi{sub 3}O{sub 2})(SeO{sub 3}){sub 2}](NO{sub 3}) and [Bi(TeO{sub 3})](NO{sub 3}) were

  10. Applicability of the ICD-11 proposal for PTSD: a comparison of prevalence and comorbidity rates with the DSM-IV PTSD classification in two post-conflict samples.

    PubMed

    Stammel, Nadine; Abbing, Eva M; Heeke, Carina; Knaevelsrud, Christine

    2015-01-01

    The World Health Organization recently proposed significant changes to the posttraumatic stress disorder (PTSD) diagnostic criteria in the 11th edition of the International Classification of Diseases (ICD-11). The present study investigated the impact of these changes in two different post-conflict samples. Prevalence and rates of concurrent depression and anxiety, socio-demographic characteristics, and indicators of clinical severity according to ICD-11 in 1,075 Cambodian and 453 Colombian civilians exposed to civil war and genocide were compared to those according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV). Results indicated significantly lower prevalence rates under the ICD-11 proposal (8.1% Cambodian sample and 44.4% Colombian sample) compared to the DSM-IV (11.2% Cambodian sample and 55.0% Colombian sample). Participants meeting a PTSD diagnosis only under the ICD-11 proposal had significantly lower rates of concurrent depression and a lower concurrent total score (depression and anxiety) compared to participants meeting only DSM-IV diagnostic criteria. There were no significant differences in socio-demographic characteristics and indicators of clinical severity between these two groups. The lower prevalence of PTSD according to the ICD-11 proposal in our samples of persons exposed to a high number of traumatic events may counter criticism of previous PTSD classifications to overuse the PTSD diagnosis in populations exposed to extreme stressors. Also another goal, to better distinguish PTSD from comorbid disorders could be supported with our data.

  11. Spectroscopic properties and energy transfer analysis of Tm3+-doped BaF2-Ga2O3-GeO2-La2O3 glass.

    PubMed

    Yu, Shenglei; Yang, Zhongmin; Xu, Shanhui

    2010-05-01

    This paper reports on the spectroscopic properties and energy transfer analysis of Tm(3+)-doped BaF(2)-Ga(2)O(3)-GeO(2)-La(2)O(3) glasses with different Tm(2)O(3) doping concentrations (0.2, 0.5, 2.0, 2.5, 3.0, 3.5, 3.5, 4.0 wt%). Mid-IR fluorescence intensities in the range of 1,300 nm-2,200 nm have been measured when excited under an 808 nm LD for all the samples with the same pump power. Energy level structure and Judd-Ofelt parameters have been calculated based on the absorption spectra of Tm(3+), cross-relaxation rates and multi-phonon relaxation rates have been estimated with different Tm(2)O(3) doping concentrations. The maximum fluorescence intensity at around 1.8 mum has been obtained in Tm(2)O(3)-3 wt% sample and the maximum value of calculated stimulated emission cross-section of Tm(3+) in this sample is about 0.48 x 10(-20) cm(2) at 1,793 nm, and there is not any crystallization peak in the DSC curve of this sample, which indicate the potential utility of Tm(3+)-doped BaF(2)-Ga(2)O(3)-GeO(2)- La(2)O(3) glass for 2.0-microm optical fiber laser.

  12. In2O3-ZnO heterostructure development in electrical and photoluminescence properties of In2O3 1-D nanostructures

    NASA Astrophysics Data System (ADS)

    Shariati, M.; Ghafouri, V.

    2014-05-01

    Indium Oxide quasi one-dimensional (1D) nanostructures known as nanowires and nanorods synthesis using the thermal evaporation method, has been articulated. To nucleate growth sites, substrate seeding promoted 1D nanostructures growth. The catalyst-mediated growth mechanism showed more favorable morphologies and physical properties in under vacuum conditions associated with bottom-up technique. Scanning electron microscopy (SEM) results showed that the Zn-doped 1D nanostructures had spherical caps. The X-ray diffraction (XRD) pattern and energy-dispersive X-ray (EDX) spectrum indicated that these caps intensively associated with ZnO. Therefore, it was reasonable that the vapor-liquid-solid mechanism (VLS) was responsible for the growth of the In2O3-ZnO heterostructure nanowires. This technique enhances optical and electrical properties in nanostructures. The photoluminescence (PL) analysis in Zn-doped In2O3 nanowires and nanorods shows that the intensity of the visible and UV-region emissions overwhelmingly increases and resistance measurement professes the improvement of linear conductance in VLS growth mechanism.

  13. Nb2O5-γ-Al2O3 nanofibers as heterogeneous catalysts for efficient conversion of glucose to 5-hydroxymethylfurfural

    NASA Astrophysics Data System (ADS)

    Jiao, Huanfeng; Zhao, Xiaoliang; Lv, Chunxiao; Wang, Yijun; Yang, Dongjiang; Li, Zhenhuan; Yao, Xiangdong

    2016-09-01

    One-dimensional γ-Al2O3 nanofibers were modified with Nb2O5 to be used as an efficient heterogeneous catalyst to catalyze biomass into 5-hydroxymethylfurfural (5-HMF). At low Nb2O5 loading, the niobia species were well dispersed on γ-Al2O3 nanofiber through Nb-O-Al bridge bonds. The interaction between Nb2O5 precursor and γ-Al2O3 nanofiber results in the niobia species with strong Lewis acid sites and intensive Brønsted acid sites, which made 5-HMF yield from glucose to reach the maximum 55.9~59.0% over Nb2O5-γ-Al2O3 nanofiber with a loading of 0.5~1 wt% Nb2O5 at 150 °C for 4 h in dimethyl sulfoxide. However, increasing Nb2O5 loading could lead to the formation of two-dimensional polymerized niobia species, three-dimensional polymerized niobia species and crystallization, which significantly influenced the distribution and quantity of the Lewis acid sites and Brönst acid sites over Nb2O5-γ-Al2O3 nanofiber. Lewis acid site Nbδ+ played a key role on the isomerization of glucose to fructose, while Brønsted acid sites are more active for the dehydration of generated fructose to 5-HMF. In addition, the heterogeneous Nb2O5-γ-Al2O3 nanofiber catalyst with suitable ratio of Lewis acid to Brönsted sites should display an more excellent catalytic performance in the conversion of glucose to 5-HMF.

  14. Electronic properties and surface reactivity of SrO-terminated SrTiO3 and SrO-terminated iron-doped SrTiO3

    PubMed Central

    Staykov, Aleksandar; Tellez, Helena; Druce, John; Wu, Ji; Ishihara, Tatsumi; Kilner, John

    2018-01-01

    Abstract Surface reactivity and near-surface electronic properties of SrO-terminated SrTiO3 and iron doped SrTiO3 were studied with first principle methods. We have investigated the density of states (DOS) of bulk SrTiO3 and compared it to DOS of iron-doped SrTiO3 with different oxidation states of iron corresponding to varying oxygen vacancy content within the bulk material. The obtained bulk DOS was compared to near-surface DOS, i.e. surface states, for both SrO-terminated surface of SrTiO3 and iron-doped SrTiO3. Electron density plots and electron density distribution through the entire slab models were investigated in order to understand the origin of surface electrons that can participate in oxygen reduction reaction. Furthermore, we have compared oxygen reduction reactions at elevated temperatures for SrO surfaces with and without oxygen vacancies. Our calculations demonstrate that the conduction band, which is formed mainly by the d-states of Ti, and Fe-induced states within the band gap of SrTiO3, are accessible only on TiO2 terminated SrTiO3 surface while the SrO-terminated surface introduces a tunneling barrier for the electrons populating the conductance band. First principle molecular dynamics demonstrated that at elevated temperatures the surface oxygen vacancies are essential for the oxygen reduction reaction. PMID:29535797

  15. Dependence of catalytic properties of Al/Fe2O3 thermites on morphology of Fe2O3 particles in combustion reactions

    NASA Astrophysics Data System (ADS)

    Zhao, Ningning; He, Cuicui; Liu, Jianbing; Gong, Hujun; An, Ting; Xu, Huixiang; Zhao, Fengqi; Hu, Rongzu; Ma, Haixia; Zhang, Jinzhong

    2014-11-01

    Three Fe2O3 particle samples with the same crystal structure but different morphologies were prepared by the hydrothermal method and then combined with Al nanoparticles to produce Al/Fe2O3 thermites using ultrasonic mixing. The properties of Fe2O3 and Al/Fe2O3 were studied using a combination of experimental techniques including scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC). The influences of the three Al/Fe2O3 thermites on the combustion properties of the AP/HTPB (ammonium perchlorate/hydroxyl-terminated polybutadiene) composite propellant were investigated in comparison to those of Fe2O3. The results show that the Al/Fe2O3 thermites are better than Fe2O3 in enhancing the combustion performance of AP/HTPB. Furthermore, the surface area, which depends on size and mophology, of Fe2O3 particles was found to play a vital role in improving the burning rate of the thermites-containing propellant formulation, with the smallest particles with the largest surface-to-volume (S/V) ratio performing the best. The enhanced catalytic property of the granular-shape Fe2O3 and the corresponding thermite is attributed to the large specific surface area of Fe2O3. The different thermal behaviors of these three superthemites were supposed to be attributed to the surface site of Fe2O3 particles. This work provides a better understanding on the catalytic properties of thermites that are important for combustion applications.

  16. Reduced anti-ferromagnetism promoted by Zn 3d 10 substitution at CuO 2 planar sites of Cu 0.5Tl 0.5Ba 2Ca 3Cu 4O 12-δ superconductors

    NASA Astrophysics Data System (ADS)

    Mumtaz, M.; Khan, Nawazish A.

    2009-11-01

    The role of charge carriers in ZnO 2/CuO 2 planes of Cu 0.5Tl 0.5Ba 2Ca 3Cu 4-yZn yO 12-δ material in bringing about superconductivity has been explained. Due to suppression of anti-ferromagnetic order with Zn 3d 10 ( S=0) substitution at Cu 3d 9(S={1}/{2}) sites in the inner CuO 2 planes of Cu 0.5Tl 0.5Ba 2Ca 3Cu 4O 12-δ superconductor, the distribution of charge carriers becomes homogeneous and optimum, which is evident from the enhanced superconductivity parameters. The decreased c-axis length with the increase of Zn doping improves interlayer coupling and hence the three dimensional (3D) conductivity in the unit cell is enhanced. Also the softening of phonon modes with the increased Zn doping indicates that the electron-phonon interaction has an essential role in the mechanism of high- Tc superconductivity in these compounds.

  17. The Vaporization of B2O3(l) to B2O3(g) and B2O2(g)

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Myers, Dwight L.

    2011-01-01

    The vaporization of B2O3 in a reducing environment leads to formation of both B2O3(g) and B2O2(g). While formation of B2O3(g) is well understood, many questions about the formation of B2O2(g) remain. Previous studies using B(s) + B2O3(l) have led to inconsistent thermodynamic data. In this study, it was found that after heating, B(s) and B2O3(l) appear to separate and variations in contact area likely led to the inconsistent vapor pressures of B2O2(g). To circumvent this problem, an activity of boron is fixed with a two-phase mixture of FeB and Fe2B. Both second and third law enthalpies of formation were measured for B2O2(g) and B2O3(g). From these the enthalpies of formation at 298.15 K are calculated to be -479.9 +/- 41.5 kJ/mol for B2O2(g) and -833.4 +/- 13.1 kJ/mol for B2O3(g). Ab initio calculations to determine the enthalpies of formation of B2O2(g) and B2O3(g) were conducted using the W1BD composite method and show good agreement with the experimental values.

  18. Strain tuning of electronic structure in Bi 4Ti 3O 12-LaCoO 3 epitaxial thin films

    DOE PAGES

    Choi, Woo Seok; Lee, Ho Nyung

    2015-05-08

    In this study, we investigated the crystal and electronic structures of ferroelectric Bi 4Ti 3O 12 single-crystalline thin films site-specifically substituted with LaCoO 3 (LCO). The epitaxial films were grown by pulsed laser epitaxy on NdGaO 3 and SrTiO 3 substrates to vary the degree of strain. With increasing the LCO substitution, we observed a systematic increase in the c-axis lattice constant of the Aurivillius phase related with the modification of pseudo-orthorhombic unit cells. These compositional and structural changes resulted in a systematic decrease in the band gap, i.e., the optical transition energy between the oxygen 2p and transition-metal 3dmore » states, based on a spectroscopic ellipsometry study. In particular, the Co 3d state seems to largely overlap with the Ti t 2g state, decreasing the band gap. Interestingly, the applied tensile strain facilitates the band-gap narrowing, demonstrating that epitaxial strain is a useful tool to tune the electronic structure of ferroelectric transition-metal oxides.« less

  19. MgSiO3-FeSiO3-Al2O3 in the Earth's lower mantle: Perovskite and garnet at 1200 km depth

    NASA Technical Reports Server (NTRS)

    O'Neill, Bridget; Jeanloz, Raymond

    1994-01-01

    Natural pyroxene and garnet starting material are used to study the effects of joint Fe and Al substitution into MgSiO3 perovskite at approxmiately 50 GPa. Garnet is found to coexist with perovskite in samples containing both Fe and Al to pressures occurring deep into the lower mantel (approximately 1200 km depth). The volume of the perovskite unit cell is V(sub o(Angstrom(exp 3)) = 162.59 + 5.95x(sub FeSiO3) + 10.80x(sub Al2O3) with aluminum causing a significant increase in the distortion from the ideal cubic cell. On the basis of a proposed extension of the MgSiO3-Al2O3 high-pressure phase diagram toward FeSiO3, Fe is shown to partition preferentially into the garnet phase. The stability of garnet deep into the lower mantel may hinder the penetration of subducted slabs below the transition zone.

  20. [Molecular docking of chlorogenic acid, 3,4-di-O-caffeoylquinic acid and 3,5-di-O-caffeoylquinic acid with human serum albumin].

    PubMed

    Zhou, Jing; Ma, Hong-yue; Fan, Xin-sheng; Xiao, Wei; Wang, Tuan-jie

    2012-10-01

    To investigate the mechanism of binding of human serum albumin (HSA) with potential sensitinogen, including chlorogenic acid and two isochlorogenic acids (3,4-di-O-caffeoylquinic acid and 3,5-di-O-caffeoylquinic acid). By using the docking algorithm of computer-aided molecular design and the Molegro Virtual Docker, the crystal structures of HSA with warfarin and diazepam (Protein Data Bank ID: 2BXD and 2BXF) were selected as molecular docking receptors of HSA sites I and II. According to docking scores, key residues and H-bond, the molecular docking mode was selected and confirmed. The molecular docking of chlorogenic acid and two isochlorogenic acids on sites I and II was compared based on the above design. The results from molecular docking indicated that chlorogenic acid, 3,4-di-O-caffeoylquinic acid and 3,5-di-O-caffeoylquinic acid could bind to HSA site I by high affinity scores of -112.3, -155.3 and -153.1, respectively. They could bind to site II on HSA by high affinity scores of -101.7, -138.5 and -133.4, respectively. In site I, two isochlorogenic acids interacted with the key apolar side-chains of Leu238 and Ala291 by higher affinity scores than chlorogenic acid. Furthermore, the H-bonds of isochlorogenic acids with polar residues inside the pocket and at the entrance of the pocket were different from chlorogenic acid. Moreover, the second coffee acyl of isochlorogenic acid occupied the right-hand apolar compartment in the pocket of HSA site I. In site I, the second coffee acyl of isochlorogenic acid formed the H-bonds with polar side-chains, which contributed isochlorogenic acid to binding with site II of HSA. The isochlorogenic acids with two coffee acyls have higher binding abilities with HSA than chlorogenic acid with one coffee acyl, suggesting that isochlorogenic acids binding with HSA may be sensitinogen.

  1. Photocatalytic self-cleaning transparent 2Bi2O3-B2O3 glass ceramics

    NASA Astrophysics Data System (ADS)

    Sharma, Sumeet Kumar; Singh, V. P.; Chauhan, Vishal S.; Kushwaha, H. S.; Vaish, Rahul

    2017-09-01

    Photocatalytic response of as-quenched and heat-treated 2Bi2O3-B2O3 glasses was studied. X ray diffraction reveals that the controlled heat treatment of glasses at 380 °C for 1 h, 2 h, and 3 h shows the formation of Bi4B2O9 crystals embedded in 2Bi2O3-B2O3 the host glass matrix. Scanning electron microscopic images reveal the presence of nanocrystallization in as-quenched glass. Significant photocatalytic activities were observed in as-quenched transparent glass. Photocatalytic activities were studied using the degradation of Resazurin as well as pharmaceutical 17 β-Estradiol under UV irradiation. Measurement of contact angle shows enhanced hydrophilicity with the increase in crystallization of the samples. Further, for as quenched 2Bi2O3-B2O3 glass ceramic, under UV irradiation, the water contact angle decreased from 92.7° to 39.5° and the sample surface transformed from hydrophobic to hydrophilic. Effective photocatalytic performance along with photoinduced hydrophilicity promotes 2Bi2O3-B2O3 glass ceramics in self-cleaning applications.

  2. Deep Learning for Automated Extraction of Primary Sites From Cancer Pathology Reports.

    PubMed

    Qiu, John X; Yoon, Hong-Jun; Fearn, Paul A; Tourassi, Georgia D

    2018-01-01

    Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. In this study, we investigated deep learning and a convolutional neural network (CNN), for extracting ICD-O-3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations as the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro- and macro-F score increases of up to 0.132 and 0.226, respectively, when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on the CNN method and cancer site. These encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.

  3. Interface Control of Ferroelectricity in an SrRuO 3/BaTiO 3/SrRuO 3 Capacitor and its Critical Thickness

    DOE PAGES

    Shin, Yeong Jae; Kim, Yoonkoo; Kang, Sung -Jin; ...

    2017-03-03

    Here, the atomic-scale synthesis of artificial oxide heterostructures offers new opportunities to create novel states that do not occur in nature. The main challenge related to synthesizing these structures is obtaining atomically sharp interfaces with designed termination sequences. In this study, it is demonstrated that the oxygen pressure (P O2) during growth plays an important role in controlling the interfacial terminations of SrRuO 3/BaTiO 3/SrRuO 3 (SRO/BTO/SRO) ferroelectric (FE) capacitors. The SRO/BTO/SRO heterostructures are grown by a pulsed laser deposition method. The top SRO/BTO interface, grown at high P O2 (around 150 mTorr), usually exhibits a mixture of RuO 2-BaOmore » and SrO-TiO 2 terminations. By reducing P O2, the authors obtain atomically sharp SRO/BTO top interfaces with uniform SrO-TiO 2 termination. Using capacitor devices with symmetric and uniform interfacial termination, it is demonstrated for the first time that the FE critical thickness can reach the theoretical limit of 3.5 unit cells.« less

  4. Ion-beam irradiation of lanthanum compounds in the systems La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whittle, Karl R., E-mail: karl.whittle@ansto.gov.a; Lumpkin, Gregory R.; Blackford, Mark G.

    2010-10-15

    Thin crystals of La{sub 2}O{sub 3}, LaAlO{sub 3}, La{sub 2/3}TiO{sub 3}, La{sub 2}TiO{sub 5}, and La{sub 2}Ti{sub 2}O{sub 7} have been irradiated in situ using 1 MeV Kr{sup 2+} ions at the Intermediate Voltage Electron Microscope-Tandem User Facility (IVEM-Tandem), Argonne National Laboratory (ANL). We observed that La{sub 2}O{sub 3} remained crystalline to a fluence greater than 3.1x10{sup 16} ions cm{sup -2} at a temperature of 50 K. The four binary oxide compounds in the two systems were observed through the crystalline-amorphous transition as a function of ion fluence and temperature. Results from the ion irradiations give critical temperatures for amorphisationmore » (T{sub c}) of 647 K for LaAlO{sub 3}, 840 K for La{sub 2}Ti{sub 2}O{sub 7}, 865 K for La{sub 2/3}TiO{sub 3}, and 1027 K for La{sub 2}TiO{sub 5}. The T{sub c} values observed in this study, together with previous data for Al{sub 2}O{sub 3} and TiO{sub 2}, are discussed with reference to the melting points for the La{sub 2}O{sub 3}-Al{sub 2}O{sub 3} and La{sub 2}O{sub 3}-TiO{sub 2} systems and the different local environments within the four crystal structures. Results suggest that there is an observable inverse correlation between T{sub c} and melting temperature (T{sub m}) in the two systems. More complex relationships exist between T{sub c} and crystal structure, with the stoichiometric perovskite LaAlO{sub 3} being the most resistant to amorphisation. - Graphical abstract: La{sub 2}TiO{sub 5} with atypical co-ordination for Ti, TiO{sub 5} is found to be different in radiation resistance to La{sub 2}Ti{sub 2}O{sub 7} and La{sub 2/3}TiO{sub 3}. Irradiation of La-Ti-O, and La-Al-O based systems has found that radiation damage resistance is related to the ability of the system to disorder.« less

  5. Chemical quenching of positronium in Fe 2O 3/Al 2O 3 catalysts

    NASA Astrophysics Data System (ADS)

    Li, C.; Zhang, H. J.; Chen, Z. Q.

    2010-09-01

    Fe 2O 3/Al 2O 3 catalysts were prepared by solid state reaction method using α-Fe 2O 3 and γ-Al 2O 3 nano powders. The microstructure and surface properties of the catalyst were studied using positron lifetime and coincidence Doppler broadening annihilation radiation measurements. The positron lifetime spectrum shows four components. The two long lifetimes τ3 and τ4 are attributed to positronium annihilation in two types of pores distributed inside Al 2O 3 grain and between the grains, respectively. With increasing Fe 2O 3 content from 3 wt% to 40 wt%, the lifetime τ3 keeps nearly unchanged, while the longest lifetime τ4 shows decrease from 96 ns to 64 ns. Its intensity decreases drastically from 24% to less than 8%. The Doppler broadening S parameter shows also a continuous decrease. Further analysis of the Doppler broadening spectra reveals a decrease in the p-Ps intensity with increasing Fe 2O 3 content, which rules out the possibility of spin-conversion of positronium. Therefore the decrease of τ4 is most probably due to the chemical quenching reaction of positronium with Fe ions on the surface of the large pores.

  6. Site-selective laser spectroscopy of Nd3+ ions in 0.8CaSiO3-0.2Ca3(PO4)2 biocompatible eutectic glass-ceramics.

    PubMed

    Sola, D; Balda, R; Peña, J I; Fernández, J

    2012-05-07

    In this work we report the influence of the crystallization stage of the host matrix on the spectroscopic properties of Nd3+ ions in biocompatible glass-ceramic eutectic rods of composition 0.8CaSiO3-0.2Ca3(PO4)2 doped with 1 and 2 wt% of Nd2O3. The samples were obtained by the laser floating zone technique at different growth rates between 50 and 500 mm/h. The microstructural analysis shows that a growth rate increase or a rod diameter decrease leads the system to a structural arrangement from three (two crystalline and one amorphous) to two phases (one crystalline and one amorphous). Electron backscattering diffraction analysis shows the presence of Ca2SiO4 and apatite-like crystalline phases. Site-selective laser spectroscopy in the (4)I(9/2)→(4)F(3/2)/(4)F(5/2) transitions confirms that Nd(3+) ions are incorporated in crystalline and amorphous phases in these glass-ceramic samples. In particular, the presence of Ca(2)SiO(4) crystalline phase in the samples grown at low rates, which has an excellent in vitro bioactivity, can be unambiguously identified from the excitation spectra and lifetime measurements of the (4)F(3/2) state of Nd(3+) ions.

  7. A unique polysaccharide containing 3-O-methylarabinose and 3-O-methylgalactose from Tinospora sinensis.

    PubMed

    Nagar, Shipra; Hensel, Andreas; Mischnick, Petra; Kumar, Vineet

    2018-08-01

    Tinospora sinensis (Lour.) Merrill is of great therapeutic significance in Indian traditional medicine. Crude polysaccharides were isolated from methanol pre-extracted stems of dried material by successive extractions with cold water, hot water and NaOH (0.25 mol/L) in 0.98, 0.55 and 0.70 % yields respectively. Cold water soluble polysaccharides (CWSP) were purified and fractionated by ion exchange chromatography on DEAE-Sephacel. Neutral polysaccharides were further fractionated on Sepharose CL6B to yield three fractions TW1, TW2, TW3. The study further focuses on structural elucidation of TW1. TW1 was obtained in 0.8 % yield relative to CWSP, with MW of 1.6 × 10 5  Da. It was composed of 3-O-methyl-arabinose, 3-O-methyl-galactose and galactose in molar ratio of 1.0:6.3:0.9 respectively. Based on per-deuteromethylation, NMR and ESI-MS analyses, TW1 was composed of 1,4-linked 3-O-methyl-β-d-galactopyranose and β-d-galactopyranose backbone with branching at O-6 of 3-O-methyl-β-d-galactosyl residues by 1,5-linked 3-O-methyl-α-l-arabinofuranoside chains. 3-O-methyl-arabinose and 3-O-methyl-galactose have first ever been reported in any polysaccharide and Tinospora genus, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. A Kinetics and Equilibrium Study of Vanadium Dissolution from Vanadium Oxides and Phosphates in Battery Electrolytes: Possible Impacts on ICD Battery Performance.

    PubMed

    Bock, David C; Marschilok, Amy C; Takeuchi, Kenneth J; Takeuchi, Esther S

    2013-06-01

    Silver vanadium oxide (Ag 2 V 4 O 11 , SVO) has enjoyed widespread commercial success over the past 30 years as a cathode material for implantable cardiac defibrillator (ICD) batteries. Recently, silver vanadium phosphorous oxide (Ag 2 VO 2 PO 4 , SVPO) has been studied as possibly combining the desirable thermal stability aspects of LiFePO 4 with the electrical conductivity of SVO. Further, due to the noted insoluble nature of most phosphate salts, a lower material solubility of SVPO relative to SVO is anticipated. Thus, the first vanadium dissolution studies of SVPO in battery electrolyte solutions are described herein. The equilibrium solubility of SVPO was ~5 times less than SVO, with a rate constant of dissolution ~3.5 times less than that of SVO. The vanadium dissolution in SVO and SVPO can be adequately described with a diffusion layer model, as supported by the Noyes-Whitney equation. Cells prepared with vanadium-treated anodes displayed higher AC impedance and DC resistance relative to control anodes. These data support the premise that SVPO cells are likely to exhibit reduced cathode solubility and thus less affected by increased cell resistance due to cathode solubility compared to SVO based cells.

  9. Nature of weak magnetism in SrTiO3/LaAlO3 multilayers.

    PubMed

    Salman, Z; Ofer, O; Radovic, M; Hao, H; Ben Shalom, M; Chow, K H; Dagan, Y; Hossain, M D; Levy, C D P; Macfarlane, W A; Morris, G M; Patthey, L; Pearson, M R; Saadaoui, H; Schmitt, T; Wang, D; Kiefl, R F

    2012-12-21

    We report the observation of weak magnetism in superlattices of LaAlO(3)/SrTiO(3) using β-detected nuclear magnetic resonance. The spin lattice relaxation rate of ^{8}Li in superlattices with a spacer layers of 8 and 6 unit cells of LaAlO(3) exhibits a strong peak near ~35 K, whereas no such peak is observed in a superlattice with spacer layer thickness of 3 unit cells. We attribute the observed temperature dependence to slowing down of weakly coupled electronic moments at the LaAlO(3)/SrTiO(3) interface. These results show that the magnetism at the interface depends strongly on the thickness of the spacer layer, and that a minimal thickness of ~4-6 unit cells is required for the appearance of magnetism. A simple model is used to determine that the observed relaxation is due to small fluctuating moments (~0.002μ(B)) in the two samples with a larger LaAlO(3) spacer thickness.

  10. Quenching of I(2P1/2) by O3 and O(3P).

    PubMed

    Azyazov, Valeriy N; Antonov, Ivan O; Heaven, Michael C

    2007-04-26

    Oxygen-iodine lasers that utilize electrical or microwave discharges to produce singlet oxygen are currently being developed. The discharge generators differ from conventional chemical singlet oxygen generators in that they produce significant amounts of atomic oxygen. Post-discharge chemistry includes channels that lead to the formation of ozone. Consequently, removal of I(2P1/2) by O atoms and O3 may impact the efficiency of discharge driven iodine lasers. In the present study, we have measured the rate constants for quenching of I(2P1/2) by O(3P) atoms and O3 using pulsed laser photolysis techniques. The rate constant for quenching by O3, (1.8 +/- 0.4) x 10(-12) cm3 s-1, was found to be a factor of 5 smaller than the literature value. The rate constant for quenching by O(3P) was (1.2 +/- 0.2) x 10(-11) cm3 s-1.

  11. Effect of RE (Nd3+, Sm3+) oxide on structural, optical properties of Na2O-Li2O-ZnO-B2O3 glass system

    NASA Astrophysics Data System (ADS)

    Hivrekar, Mahesh M.; Bhoyar, D. N.; Mande, V. K.; Dhole, V. V.; Solunke, M. B.; Jadhav, K. M.

    2018-05-01

    Zinc borate glass activated with rare earth oxide (Nd2O3, Sm2O3) of Na2O-Li2O-ZnO-B2O3 quaternary system has been prepared successfully by melt quenching method. The nucleation and growth of RE oxide were controlled temperature range 950-1000° C and rapid cooling at room temperature. The physical, structural and optical properties were characterized by using X-ray diffraction (XRD), SEM, Ultraviolet-visible spectroscopy (UV-Vis). XRD and SEM studies confirmed the amorphous nature, surface morphology of prepared zinc borate glass. The physical parameters like density, molar volume, molar mass of Nd3+, Sm3+ doped borate glass are summarized in the present article. The optical absorption spectra along with tauc's plot are presented. The optical energy band gap increases due to the addition of rare earth oxide confirming the role of network modifier.

  12. Properties of highly (100) oriented Pb(Mg1/3,Nb2/3)O3-PbTiO3 films on LaNiO3 bottom electrodes

    NASA Astrophysics Data System (ADS)

    Li, Y. W.; Hu, Z. G.; Yue, F. Y.; Yang, G. Y.; Shi, W. Z.; Meng, X. J.; Sun, J. L.; Chu, J. H.

    2007-12-01

    The 70%Pb(Mg1/3,Nb2/3)O3-30%PbTiO3 (PMNT) films have been fabricated on LaNiO3 (LNO) coated silicon substrate. The conductive LNO films act as a seed layer for the growth of PMNT films, which depresses the formation of pyrochlore phase and induces the high (100) preferred orientation of perovskite PMNT films. Compared with the PMNT films grown on platinum bottom electrode, the ferroelectric properties of PMNT films grown on LNO are enhanced. The frequency dependence of complex permittivity from PMNT films on LNO is the conjunct result of polarization relaxation and movement of oxygen vacancy, which can be fitted by the function containing Debye and universal dielectric response models, respectively.

  13. Epitaxial growth and magnetic properties of ultraviolet transparent Ga2O3/(Ga1-xFex)2O3 multilayer thin films.

    PubMed

    Guo, Daoyou; An, Yuehua; Cui, Wei; Zhi, Yusong; Zhao, Xiaolong; Lei, Ming; Li, Linghong; Li, Peigang; Wu, Zhenping; Tang, Weihua

    2016-04-28

    Multilayer thin films based on the ferromagnetic and ultraviolet transparent semiconductors may be interesting because their magnetic/electronic/photonic properties can be manipulated by the high energy photons. Herein, the Ga2O3/(Ga1-xFex)2O3 multilayer epitaxial thin films were obtained by alternating depositing of wide band gap Ga2O3 layer and Fe ultrathin layer due to inter diffusion between two layers at high temperature using the laser molecular beam epitaxy technique. The multilayer films exhibits a preferred growth orientation of crystal plane, and the crystal lattice expands as Fe replaces Ga site. Fe ions with a mixed valence of Fe(2+) and Fe(3+) are stratified distributed in the film and exhibit obvious agglomerated areas. The multilayer films only show a sharp absorption edge at about 250 nm, indicating a high transparency for ultraviolet light. What's more, the Ga2O3/(Ga1-xFex)2O3 multilayer epitaxial thin films also exhibits room temperature ferromagnetism deriving from the Fe doping Ga2O3.

  14. High-resolution 17O double-rotation NMR characterization of ring and non-ring oxygen in vitreous B2O3.

    PubMed

    Wong, Alan; Howes, Andy P; Parkinson, Ben; Anupõld, Tiit; Samoson, Ago; Holland, Diane; Dupree, Ray

    2009-08-28

    The application of double rotation (DOR) NMR to crystalline materials (both inorganic and organic) has made tremendous strides in providing site-specific information about materials in recent years. However (17)O DOR has yet to demonstrate its potential in disordered materials such as glasses. In the present study, we have successfully recorded high resolution (17)O DOR spectra of vitreous B(2)O(3) (v-B(2)O(3)), a highly effective glass-forming oxide of considerable technological importance. Two distinct oxygen sites are resolved and a complete set of (17)O NMR parameters were determined from the DOR spectra. These were assigned to oxygen atoms in the planar boroxol ring [B(3)O(6)] and in the non-boroxol [BO(3)] groups which share oxygen with the ring boron atoms. This assignment was based on the similarity of all of their (17)O parameters with those found by DFT calculation for caesium enneaborate, Cs(2)O.9B(2)O(3), which has two boroxol rings in its structure. The boroxol ring oxygens have a more positive chemical shift, a larger shift anisotropy and a smaller electric field gradient than non ring oxygens (O(R): delta(iso) = 100 +/- 1 ppm, span = 180 +/- 20 ppm, skew = -0.4 +/- 0.1, P(q) = 5.0 +/- 0.2 MHz; O(NR): delta(iso) = 86 +/- 1 ppm, span = 100 +/- 20 ppm, skew = 0.1 +/- 0.1, P(q) = 5.7 +/- 0.2 MHz). The relative proportions of the two sites in v-B(2)O(3) are approximately 1 : 1, as expected if all three boron atoms in the boroxol ring are each connected to one oxygen in a linking [BO(3)] group and there are very few [BO(3)]-[BO(3)] linkages. We see no evidence for a third oxygen site such as has been reported in an earlier study of v-B(2)O(3). This work demonstrates the potential of (17)O DOR to provide site-specific information in disordered materials.

  15. High-pressure synthesis of the cubic perovskite BaRuO3 and evolution of ferromagnetism in ARuO3 (A = Ca, Sr, Ba) ruthenates.

    PubMed

    Jin, C-Q; Zhou, J-S; Goodenough, J B; Liu, Q Q; Zhao, J G; Yang, L X; Yu, Y; Yu, R C; Katsura, T; Shatskiy, A; Ito, E

    2008-05-20

    The cubic perovskite BaRuO(3) has been synthesized under 18 GPa at 1,000 degrees C. Rietveld refinement indicates that the new compound has a stretched Ru-O bond. The cubic perovskite BaRuO(3) remains metallic to 4 K and exhibits a ferromagnetic transition at T(c) = 60 K, which is significantly lower than the T(c) approximately = 160 K for SrRuO(3). The availability of cubic perovskite BaRuO(3) not only makes it possible to map out the evolution of magnetism in the whole series of ARuO(3) (A = Ca, Sr, Ba) as a function of the ionic size of the A-site r(A,) but also completes the polytypes of BaRuO(3). Extension of the plot of T(c) versus r(A) in perovskites ARuO(3) (A = Ca, Sr, Ba) shows that T(c) does not increase as the cubic structure is approached, but has a maximum for orthorhombic SrRuO(3). Suppressing T(c) by Ca and Ba doping in SrRuO(3) is distinguished by sharply different magnetic susceptibilities chi(T) of the paramagnetic phase. This distinction has been interpreted in the context of a Griffiths' phase on the (Ca Sr)RuO(3) side and bandwidth broadening on the (Sr,Ba)RuO(3) side.

  16. High-pressure synthesis of the cubic perovskite BaRuO3 and evolution of ferromagnetism in ARuO3 (A = Ca, Sr, Ba) ruthenates

    PubMed Central

    Jin, C.-Q.; Zhou, J.-S.; Goodenough, J. B.; Liu, Q. Q.; Zhao, J. G.; Yang, L. X.; Yu, Y.; Yu, R. C.; Katsura, T.; Shatskiy, A.; Ito, E.

    2008-01-01

    The cubic perovskite BaRuO3 has been synthesized under 18 GPa at 1,000°C. Rietveld refinement indicates that the new compound has a stretched Ru–O bond. The cubic perovskite BaRuO3 remains metallic to 4 K and exhibits a ferromagnetic transition at Tc = 60 K, which is significantly lower than the Tc ≈ 160 K for SrRuO3. The availability of cubic perovskite BaRuO3 not only makes it possible to map out the evolution of magnetism in the whole series of ARuO3 (A = Ca, Sr, Ba) as a function of the ionic size of the A-site rA, but also completes the polytypes of BaRuO3. Extension of the plot of Tc versus rA in perovskites ARuO3 (A = Ca, Sr, Ba) shows that Tc does not increase as the cubic structure is approached, but has a maximum for orthorhombic SrRuO3. Suppressing Tc by Ca and Ba doping in SrRuO3 is distinguished by sharply different magnetic susceptibilities χ(T) of the paramagnetic phase. This distinction has been interpreted in the context of a Griffiths' phase on the (Ca Sr)RuO3 side and bandwidth broadening on the (Sr,Ba)RuO3 side. PMID:18480262

  17. Ni doped Fe3O4 magnetic nanoparticles.

    PubMed

    Larumbe, S; Gómez-Polo, C; Pérez-Landazábal, J I; García-Prieto, A; Alonso, J; Fdez-Gubieda, M L; Cordero, D; Gómez, J

    2012-03-01

    In this work, the effect of nickel doping on the structural and magnetic properties of Fe3O4 nanoparticles is analysed. Ni(x)Fe(3-x)O4 nanoparticles (x = 0, 0.04, 0.06 and 0.11) were obtained by chemical co-precipitation method, starting from a mixture of FeCl2 x 4H2O and Ni(AcO)2 x 4H2O salts. The analysis of the structure and composition of the synthesized nanoparticles confirms their nanometer size (main sizes around 10 nm) and the inclusion of the Ni atoms in the characteristic spinel structure of the magnetite Fe3O4 phase. In order to characterize in detail the structure of the samples, X-ray absorption (XANES) measurements were performed on the Ni and Fe K-edges. The results indicate the oxidation of the Ni atoms to the 2+ state and the location of the Ni2+ cations in the Fe2+ octahedral sites. With respect to the magnetic properties, the samples display the characteristic superparamagnetic behaviour, with anhysteretic magnetic response at room temperature. The estimated magnetic moment confirms the partial substitution of the Fe2+ cations by Ni2+ atoms in the octahedral sites of the spinel structure.

  18. Optical properties of the Al2O3/SiO2 and Al2O3/HfO2/SiO2 antireflective coatings

    NASA Astrophysics Data System (ADS)

    Marszałek, Konstanty; Winkowski, Paweł; Jaglarz, Janusz

    2014-01-01

    Investigations of bilayer and trilayer Al2O3/SiO2 and Al2O3/HfO2/SiO2 antireflective coatings are presented in this paper. The oxide films were deposited on a heated quartz glass by e-gun evaporation in a vacuum of 5 × 10-3 [Pa] in the presence of oxygen. Depositions were performed at three different temperatures of the substrates: 100 °C, 200 °C and 300 °C. The coatings were deposited onto optical quartz glass (Corning HPFS). The thickness and deposition rate were controlled with Inficon XTC/2 thickness measuring system. Deposition rate was equal to 0.6 nm/s for Al2O3, 0.6 nm - 0.8 nm/s for HfO2 and 0.6 nm/s for SiO2. Simulations leading to optimization of the thin film thickness and the experimental results of optical measurements, which were carried out during and after the deposition process, have been presented. The optical thickness values, obtained from the measurements performed during the deposition process were as follows: 78 nm/78 nm for Al2O3/SiO2 and 78 nm/156 nm/78 nm for Al2O3/HfO2/SiO2. The results were then checked by ellipsometric technique. Reflectance of the films depended on the substrate temperature during the deposition process. Starting from 240 nm to the beginning of visible region, the average reflectance of the trilayer system was below 1 % and for the bilayer, minima of the reflectance were equal to 1.6 %, 1.15 % and 0.8 % for deposition temperatures of 100 °C, 200 °C and 300 °C, respectively.

  19. Interfacial Ferromagnetism and Exchange Bias in CaRuO3/CaMnO3 Superlattices

    NASA Astrophysics Data System (ADS)

    He, C.; Grutter, A. J.; Gu, M.; Browning, N. D.; Takamura, Y.; Kirby, B. J.; Borchers, J. A.; Kim, J. W.; Fitzsimmons, M. R.; Zhai, X.; Mehta, V. V.; Wong, F. J.; Suzuki, Y.

    2012-11-01

    We have found ferromagnetism in epitaxially grown superlattices of CaRuO3/CaMnO3 that arises in one unit cell at the interface. Scanning transmission electron microscopy and electron energy loss spectroscopy indicate that the difference in magnitude of the Mn valence states between the center of the CaMnO3 layer and the interface region is consistent with double exchange interaction among the Mn ions at the interface. Polarized neutron reflectivity and the CaMnO3 thickness dependence of the exchange bias field together indicate that the interfacial ferromagnetism is only limited to one unit cell of CaMnO3 at each interface. The interfacial moment alternates between the 1μB/interface Mn ion for even CaMnO3 layers and the 0.5μB/interface Mn ion for odd CaMnO3 layers. This modulation, combined with the exchange bias, suggests the presence of a modulating interlayer coupling between neighboring ferromagnetic interfaces via the antiferromagnetic CaMnO3 layers.

  20. Interface magnetism and electronic structure: ZnO(0001)/Co3O4 (111)

    NASA Astrophysics Data System (ADS)

    Kupchak, I. M.; Serpak, N. F.; Shkrebtii, A.; Hayn, R.

    2018-03-01

    We have studied the structural, electronic, and magnetic properties of spinel Co3O4 (111) surfaces and their interfaces with ZnO(0001) using density functional theory within the generalized gradient approximation with the on-site Coulomb repulsion term. Two possible forms of spinel surface, containing Co2 + or Co3 + ions and terminated with either cobalt or oxygen ions, were considered, as well as their interface with zinc oxide. Our calculations demonstrate that Co3 + ions attain nonzero magnetic moments at the surface and interface, in contrast to the bulk, where they are not magnetic, leading to the ferromagnetic ordering. Since heavily Co doped ZnO samples can contain a Co3O4 secondary phase, such magnetic ordering at the interface might explain the origin of the magnetism in such diluted magnetic semiconductors.

  1. Thermal characteristics, Raman spectra, optical and structural properties of TiO2-Bi2O3-B2O3-TeO2 glasses

    NASA Astrophysics Data System (ADS)

    Gupta, Nupur; Khanna, Atul; Gonzàlez, Fernando; Iordanova, Reni

    2017-05-01

    Tellurite and borotellurite glasses containing Bi2O3 and TiO2 were prepared and structure-property correlations were carried out by density measurements, X-ray Diffraction (XRD), Differential Scanning Calorimetry (DSC), Raman and UV-visible spectroscopy. Titanium tellurite glasses require high melt-cooling rates and were fabricated by splat quenching. On adding B2O3, the glass forming ability (GFA) enhances, and glasses could be synthesized at lower quenching rates. The density of glasses shows a direct correlation with molecular mass of the constituents. UV-visible studies were used to determine the optical band gap and refractive index. Raman studies found that the co-ordination number of tellurium ions with oxygen (NTe-O) decreases with the increase in B2O3 as well as Bi2O3 content while, TiO2 produce only a small decrease in NTe-O, which explains the lower GFA of titanium tellurite glasses that do not contain Bi2O3 and B2O3. DSC studies show that the glass transition temperature (Tg) increases with B2O3 and TiO2 concentrations and that Tg correlates well with bond enthalpy of the metal oxides.

  2. Magnetic transition in Y-site doped multiferroic YMnO{sub 3}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thakur, Rajesh K., E-mail: thakur.rajesh2009@gmail.com; Thakur, Rasna, E-mail: rasnathakur@yahoo.com; Gaur, N. K., E-mail: srl-nkgaur@yahoo.co.in

    2016-05-06

    We have synthesized polycrystalline hexagonal Y{sub 1-x}Sr{sub x}MnO{sub 3} (x=0.02, 0.1) compounds by using conventional solid state reaction method. The detailed structural investigations are carried out by using XRD studies which reveals the single phase formation of the reported compounds with hexagonal structure and space group P6{sub 3}cm (JCPDS: 25-1079). Further the XRD data of reported compounds were analyzed by RIETVELD (FULLPROFF) method which shows the decrease in the lattice parameter with increasing concentration of divalent strontium to Y-site. The observed pointed kinks in the specific heat study are indicative of the probable coupling in between the electric and magneticmore » orders in this class of materials. The reported systematic specific heat studies shows that the antiferromagnetic (AFM) transition temperature (T{sub N}) shifts to higher value with increasing concentration of Sr{sup 2+} ion in the YMnO{sub 3} compound which is attributed to the enhanced lattice contribution to the specific heat in the this compound. The present compound shows the independence of specific heat and magnetic transition temperature with applied magnetic field of 8T and 12T.« less

  3. The solubility and site preference of Fe{sup 3+} in Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rettenwander, D., E-mail: daniel.rettenwander@sbg.ac.at; Geiger, C.A.; Tribus, M.

    2015-10-15

    A series of Fe{sup 3+}-bearing Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} (LLZO) garnets was synthesized using solid-state synthesis methods. The synthetic products were characterized compositionally using electron microprobe analysis and inductively coupled plasma optical emission spectroscopy (ICP-OES) and structurally using X-ray powder diffraction and {sup 57}Fe Mössbauer spectroscopy. A maximum of about 0.25 Fe{sup 3+} pfu could be incorporated in Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnet solid solutions. At Fe{sup 3+} concentrations lower than about 0.16 pfu, both tetragonal and cubic garnets were obtained in the synthesis experiments. X-ray powder diffraction analysis showed only a garnet phase for syntheses withmore » starting materials having intended Fe{sup 3+} contents lower than 0.52 Fe{sup 3+} pfu. Back-scattered electron images made with an electron microprobe also showed no phase other than garnet for these compositions. The lattice parameter, a{sub 0}, for all solid-solution garnets is similar with a value of a{sub 0}≈12.98 Å regardless of the amount of Fe{sup 3+}. {sup 57}Fe Mössbauer spectroscopic measurements indicate the presence of poorly- or nano-crystalline FeLaO{sub 3} in syntheses with Fe{sup 3+} contents greater than 0.16 Fe{sup 3+} pfu. The composition of different phase pure Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnets, as determined by electron microprobe (Fe, La, Zr) and ICP-OES (Li) measurements, give Li{sub 6.89}Fe{sub 0.03}La{sub 3.05}Zr{sub 2.01}O{sub 12}, Li{sub 6.66}Fe{sub 0.06}La{sub 3.06}Zr{sub 2.01}O{sub 12}, Li{sub 6.54}Fe{sub 0.12}La{sub 3.01}Zr{sub 1.98}O{sub 12}, and Li{sub 6.19}Fe{sub 0.19}La{sub 3.02}Zr{sub 2.04}O{sub 12}. The {sup 57}Fe Mössbauer spectrum of cubic Li{sub 6.54}Fe{sub 0.12}La{sub 3.01}Zr{sub 1.98}O{sub 12} garnet indicates that most Fe{sup 3+} occurs at the special crystallographic 24d position, which is the standard tetrahedrally coordinated site in garnet. Fe{sup 3+} in

  4. Self-assembly and hierarchical organization of Ga2O3/In2O3 nanostructures.

    PubMed

    Xu, Liang; Su, Yong; Li, Sen; Chen, Yiqing; Zhou, Qingtao; Yin, Song; Feng, Yi

    2007-02-01

    We report on the realization of novel 3-D hierarchical heterostructures with 6-and 4-fold symmetries by a transport and condensation technique. It was found that the major core nanowires or nanobelts are single-crystalline In2O3, and the secondary nanorods are single-crystalline monoclinic beta-Ga2O3 and grow either perpendicular on or slanted to all the facets of the core In2O3 nanobelts. Depending on the diameter of the core In2O3 nanostructures, the secondary Ga2O3 nanorods grow either as a single row or multiple rows. The one-step growth of the unique Ga2O3/In2O3 heteronanostructures is a spontaneous and self-organized process. The simultaneous control of nanocrystal size and shape together with the possibility of growing heterostructures on certain nanocrystal facets opens up novel routes to the synthesis of more sophisticated heterostructures as building blocks for opto- and nanoelectronics.

  5. Effects of PbO-B2O3 Glass Doping on the Sintering Temperature and Piezoelectric Properties of 0.35Pb (Ni1/3Nb2/3)O3-0.65Pb(Zr0.41Ti0.59)O3 Ceramics

    NASA Astrophysics Data System (ADS)

    Yi, Jinqiao; Shen, Meng; Liu, Sisi; Jiang, Shenglin

    2015-12-01

    0.35Pb(Ni1/3Nb2/3)O3-0.65Pb(Zr0.41Ti0.59)O3 (PNN-PZT) ceramics doped with 0.5PbO-0.5B2O3 glass have been synthesized by the conventional solid-state sintering technique. The effects of 0.5PbO-0.5B2O3 glass on the sintering temperature and piezoelectric properties of PNN-PZT ceramics were studied. The results indicated that the sintering temperature of PNN-PZT was significantly reduced due to the incorporation of 0.5PbO-0.5B2O3 glass dopant. When the content of 0.5PbO-0.5B2O3 glass was 0.5 wt.%, the sintering temperature of PNN-PZT was observed to reduce from above 1200°C to 920°C while the samples maintained high density (7.91 g/cm3), excellent piezoelectric constant ( d 33 = 479 pC/N), large electromechanical coupling coefficient ( K p = 0.55), and relatively low electromechanical quality factor ( Q m = 79). Moreover, large dielectric constant ( ɛ 33 T / ɛ 0 = 2904) and low dielectric loss (tan δ = 0.0166) were obtained in this work.

  6. Optical spectroscopy of Sm(3+) doped Na2O-ZnO-La2O3-TeO2 glasses.

    PubMed

    Sobczyk, Marcin

    2015-10-05

    Telluride glasses with the composition xSm2O3-(7-x)La2O3-3Na2O-25ZnO-65TeO2 (where x=0.1, 1, 2, 5 and 7 mol%) were obtained by the melt quenching technique. Electronic absorption and fluorescence spectra as well as fluorescence dynamics of the Sm(3+)-doped title glasses are presented and analysed in detail. A Judd-Ofelt intensity analysis of the absorption spectrum at 300 K has been applied for determination of Ωλ parameters (Ω2=3.10, Ω4=3.80, Ω6=1.61×10(-20) cm(2)) which in turn have been used for calculations of the radiative transition probabilities (AT), the natural (radiative) lifetimes (τR) of the (4)G5/2 level of Sm(3+), the fluorescence branching ratios (β) and the emission cross-sections (σem). The τR value of the (4)G5/2 level amount to 1546 μs and is slightly higher than the measured decay time of 1306 μs. With the increasing of Sm2O3 concentration from 0.1 to 7.0 mol% the experimental lifetime of the fluorescent level decreases from 1306 to 41 μs. An analysis of the non-radiative decay was based on the cross-relaxation mechanisms. The optical achieved results indicate that the investigated glasses are potentially applicable as an orange and/or red laser host. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Underestimated prevalence of heart failure in hospital inpatients: a comparison of ICD codes and discharge letter information.

    PubMed

    Kaspar, Mathias; Fette, Georg; Güder, Gülmisal; Seidlmayer, Lea; Ertl, Maximilian; Dietrich, Georg; Greger, Helmut; Puppe, Frank; Störk, Stefan

    2018-04-17

    Heart failure is the predominant cause of hospitalization and amongst the leading causes of death in Germany. However, accurate estimates of prevalence and incidence are lacking. Reported figures originating from different information sources are compromised by factors like economic reasons or documentation quality. We implemented a clinical data warehouse that integrates various information sources (structured parameters, plain text, data extracted by natural language processing) and enables reliable approximations to the real number of heart failure patients. Performance of ICD-based diagnosis in detecting heart failure was compared across the years 2000-2015 with (a) advanced definitions based on algorithms that integrate various sources of the hospital information system, and (b) a physician-based reference standard. Applying these methods for detecting heart failure in inpatients revealed that relying on ICD codes resulted in a marked underestimation of the true prevalence of heart failure, ranging from 44% in the validation dataset to 55% (single year) and 31% (all years) in the overall analysis. Percentages changed over the years, indicating secular changes in coding practice and efficiency. Performance was markedly improved using search and permutation algorithms from the initial expert-specified query (F1 score of 81%) to the computer-optimized query (F1 score of 86%) or, alternatively, optimizing precision or sensitivity depending on the search objective. Estimating prevalence of heart failure using ICD codes as the sole data source yielded unreliable results. Diagnostic accuracy was markedly improved using dedicated search algorithms. Our approach may be transferred to other hospital information systems.

  8. Phase Equilibria and Crystal Chemistry in Portions of the System SrO-CaO-Bi2O3-CuO, Part IV— The System CaO-Bi2O3-CuO

    PubMed Central

    Burton, B. P.; Rawn, C. J.; Roth, R. S.; Hwang, N. M.

    1993-01-01

    New data are presented on the phase equilibria and crystal chemistry of the binary systems CaO-Bi2O3 and CaO-CuO and the ternary CaO-Bi2O3-CuO. Symmetry data and unit cell dimensions based on single crystal and powder x-ray diffraction measurements are reported for several of the binary CaO-Bi2O3 phases, including corrected compositions for Ca4Bi6O13 and Ca2Bi2O5. The ternary system contains no new ternary phases which can be formed in air at ~700–900 °C. PMID:28053484

  9. Investigation of thermal stability and spectroscopic properties in Er3+/Yb3+-codoped TeO2-Li2O-B2O3-GeO2 glasses.

    PubMed

    Nie, Qiu-Hua; Gao, Yuan; Xu, Tie-Feng; Shen, Xiang

    2005-06-01

    The new Er3+/Yb3+ co-doped 70TeO2-5Li2O-(25-x)B2O3-xGeO2 (x = 0, 5, 10, 15 fand 20 mol.%) glasses were prepared. The thermal stability, absorption spectra, emission spectra and lifetime of the 4I(13/2) level of Er3+ ions were measured and studied. The FT-IR spectra were carried out in order to investigate the structure of local arrangements in glasses. It is found that the thermal stability, absorption cross-section of Yb3+, emission intensity and lifetime of the 4I(13/2) level of Er3+ increase with increasing GeO2 content in the glass composition, while the fluorescence width at half maximum (FWHM) at 1.5 um of Er3+ is about 70 nm. The obtained data suggest that this system glass can be used as a candidate host material for potential broadband optical amplifiers.

  10. Thermodynamic Properties of α-Fe 2O 3 and Fe 3O 4 Nanoparticles

    DOE PAGES

    Spencer, Elinor C.; Ross, Nancy L.; Olsen, Rebecca E.; ...

    2015-04-21

    Here we comprehansively assessed the thermodynamic properties of hydrated α-Fe 2O 3 (hematite) and Fe 3O 4 (magnetite) nanoparticles. In addition to 9 nm Fe 3O 4, three α-e 2O 3nanoparticles samples of different sizes (11, 14, and 25 nm) and bulk α-e 2O 3 have been evaluated by inelastic neutron scattering methods. The contribution of the two-level magnetic spin flip transition to the heat capacity of the α-e 2O 3 particles has been determined. The isochoric heat capacity of the water confined on the surface of these two types of iron oxide particles have been calculated from their INSmore » spectra, and is affected by the chemical composition of the underlying particle. Furthermore, the heat capacity and dynamics of the particle hydration layers appear to be influenced by a complex array of factors including particle size, water coverage, and possibly the magnetic state of the particle itself.« less

  11. Preparation of Er3+:Y3Al5O12/WO3-KNbO3 composite and application in treatment of methamphetamine under ultrasonic irradiation.

    PubMed

    Zhang, Hongbo; Huang, Yingying; Li, Guanshu; Wang, Guowei; Fang, Dawei; Song, Youtao; Wang, Jun

    2017-03-01

    Er 3+ :Y 3 Al 5 O 12 /WO 3 -KNbO 3 composite powder as an effective sonocatalyst was prepared via collosol-gelling-hydrothermal and high-temperature calcination methods. The textures of materials were observed by X-ray diffractometer (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). In order to estimate the sonocatalytic activity of Er 3+ :Y 3 Al 5 O 12 /WO 3 -KNbO 3 composite powder, the sonocatalytic degradation of methamphetamine (MAPA) was performed. Furthermore, the influences of mass ratio of WO 3 and KNbO 3 , ultrasonic irradiation time, catalyst addition amount, initial methamphetamine (MAPA) concentration and used times on the sonocatalytic degradation of methamphetamine (MAPA) caused by Er 3+ :Y 3 Al 5 O 12 /WO 3 -KNbO 3 composite powder were investigated by using gas chromatography. Under optimal conditions of 1.00g/L Er 3+ :Y 3 Al 5 O 12 /WO 3 -KNbO 3 addition amount and 10.00mg/L methamphetamine (MAPA) initial concentration, 68% of methamphetamine (MAPA) could be removed after 150min ultrasonic irradiation. The experimental results showed that the Er 3+ :Y 3 Al 5 O 12 /WO 3 -KNbO 3 as sonocatalyst displayed an excellent sonocatalytic activity in degradation of methamphetamine (MAPA) under ultrasonic irradiation. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Medical Surveillance Monthly Report (MSMR). Volume 6, Number 3, March 2000

    DTIC Science & Technology

    2000-03-01

    Rocky Mountain spotted fever (RMSF), are more common in temperate regions such as the United States...0.2 1. Through September 30, 1999. Characteristics N Rate2 Malaria Rocky Mountain Spotted Fever Rate2NRate2 Lyme disease 3. IAW DoD Occupational...085.9); Lyme disease (ICD-9-CM code: 088.81); dengue fever (ICD-9-CM code: 061); or Rocky Mountain spotted fever (ICD-9-CM code: 082.0). If an

  13. Porous nanocubic Mn3O4-Co3O4 composites and their application as electrochemical supercapacitors.

    PubMed

    Pang, Huan; Deng, Jiawei; Du, Jimin; Li, Sujuan; Li, Juan; Ma, Yahui; Zhang, Jiangshan; Chen, Jing

    2012-09-14

    A simple approach has been developed to fabricate ideal supercapacitors based on porous Mn(3)O(4)-Co(3)O(4) nanocubic composite electrodes. We can easily obtain porous corner-truncated nanocubic Mn(3)O(4)-Co(3)O(4) composite nanomaterials without any subsequent complicated workup procedure for the removal of a hard template, seed or by using a soft template. In such a composite, the porous Mn(3)O(4)-Co(3)O(4) enables a fast and reversible redox reaction to improve the specific capacitance. The porous nanocubic Mn(3)O(4)-Co(3)O(4) composite electrode can effectively transport electrolytes and shorten the ion diffusion path, which offers excellent electrochemical performance. These results suggest that such porous Mn(3)O(4)-Co(3)O(4) composite nanocubes are very promising for next generation high-performance supercapacitors.

  14. α-Al2O3/Ga2O3 superlattices coherently grown on r-plane sapphire

    NASA Astrophysics Data System (ADS)

    Oshima, Takayoshi; Kato, Yuji; Imura, Masataka; Nakayama, Yoshiko; Takeguchi, Masaki

    2018-06-01

    Ten-period binary α-Al2O3/Ga2O3 superlattices were fabricated on r-plane sapphire substrates by molecular beam epitaxy. By systematic variation of α-Ga2O3 thickness and evaluation through X-ray reflectivity and diffraction measurements and scanning transmission electron microscopy, we verified that the superlattice with α-Ga2O3 thickness up to ∼1 nm had coherent interfaces without misfit dislocation in spite of the large lattice mismatches. This successful fabrication of coherent α-Al2O3/Ga2O3 superlattices will encourage further development of α-(Al x Ga1‑ x )2O3-based heterostructures including superlattices.

  15. Site-selective doping and superconductivity in (La1-yPry)(Ba2-xLax)Cu3O7+δ

    NASA Astrophysics Data System (ADS)

    Mitzi, D. B.; Feffer, P. T.; Newsam, J. M.; Webb, D. J.; Klavins, P.; Jacobson, A. J.; Kapitulnik, A.

    1988-10-01

    Samples in the quaternary system (La1-yPry)(Ba2-xLax)Cu3O7+δ have been prepared and characterized using x-ray and neutron diffraction, thermogravimetric analysis, and transport and magnetic measurements. Pr substitutes on the oxygen-depleted La layers for y>0.0, while La substitutes on the Ba sites for x>0.0. The effect of doping on each site is inferred to be primarily local, affecting immediately adjacent Cu-O layers. The similar suppression of superconductivity that accompanies doping on each of the two distinct sites apparently correlates with the degree of oxidation of the Cu-O sheets (and not the chains), indicating that the sheets support the high temperature superconductivity. Comparison of orthorhombic and tetragonal samples with similar Ba:La ratios (and y=0) demonstrates that the orthorhombic phase yields the largest Meissner signals and highest transition temperatures in the La(Ba2-xLax)Cu3O7+δ system. The effect on superconductivity of oxygen-vacancy configuration in the Cu-O chain layers is proposed to derive, indirectly, from their influence on the Cu-O sheets. In addition, optimally superconducting La(Ba2-xLax)Cu3O7+δ samples exhibit interesting normal-state magnetic properties, with a paramagnetic susceptibility that decreases steadily with temperature between 350 K and Tc.

  16. Nqrs Data for H6I3InO12 [I3InO3(H2O)] (Subst. No. 2289)

    NASA Astrophysics Data System (ADS)

    Chihara, H.; Nakamura, N.

    This document is part of Subvolume B 'Substances Containing C10H16 … Zn' of Volume 48 'Nuclear Quadrupole Resonance Spectroscopy Data' of Landolt-Börnstein - Group III 'Condensed Matter'. It contains an extract of Section '3.2 Data tables' of the Chapter '3 Nuclear quadrupole resonance data' providing the NQRS data for H6I3InO12 [I3InO3(H2O)] (Subst. No. 2289)

  17. Quenching of I(2P 1/2) by O 3 and O( 3P)

    NASA Astrophysics Data System (ADS)

    Azyazov, V. N.; Antonov, I. O.; Ruffner, S.; Heaven, M. C.

    2006-02-01

    Oxygen-iodine lasers that utilize electrical or microwave discharges to produce singlet oxygen are currently being developed. The discharge generators differ from conventional chemical singlet oxygen generators in that they produce significant amounts of atomic oxygen. Post-discharge chemistry includes channels that lead to the formation of ozone. Consequently, removal of I(2P 1/2) by O atoms and O 3 may impact the efficiency of discharge driven iodine lasers. In the present study we have measured the rate constants for quenching of I(2P 1/2) by O( 3P) atoms and O 3 using pulsed laser photolysis techniques. The rate constant for quenching by O 3, 1.8x10 -12 cm 3 s -1, was found to be a factor of five smaller than the literature value. The rate constant for quenching by O( 3P) was 1.2x10 -11 cm 3 s -1. This was six times larger than a previously reported upper bound, but consistent with estimates obtained by modeling the kinetics of discharge-driven laser systems.

  18. Enhanced magnetoelectric response in 2-2 bilayer 0.50Pb(Ni1/3Nb2/3)O3-0.35PbTiO3-0.15PbZrO3/NiFe2O4 thin films

    NASA Astrophysics Data System (ADS)

    Ade, Ramesh; Sambasiva, V.; Kolte, Jayant; Karthik, T.; Kulkarni, Ajit R.; Venkataramani, N.

    2018-03-01

    In this work, room temperature magnetoelectric (ME) properties of 0.50Pb(Ni1/3Nb2/3)O3-0.35PbTiO3-0.15PbZrO3 (PNNZT)/NiFe2O4 (NFO) 2-2 bilayer thin films grown on Pt/Ti/SiO2/Si substrate, using pulsed laser deposition technique, are reported. Structural studies confirm single phase PNNZT/NFO 2-2 bilayer structure formation. PNNZT/NFO 2-2 bilayer thin film shows a maximum ME voltage coefficient (α E ) of ~0.70 V cm-1. Oe-1 at a frequency of 1 kHz. The present study reveals that PNNZT/NFO bilayer thin film can be a potential candidate for technological applications.

  19. Air Plasma-Sprayed La2Zr2O7-SrZrO3 Composite Thermal Barrier Coating Subjected to CaO-MgO-Al2O3-SiO2 (CMAS)

    NASA Astrophysics Data System (ADS)

    Cai, Lili; Ma, Wen; Ma, Bole; Guo, Feng; Chen, Weidong; Dong, Hongying; Shuang, Yingchai

    2017-08-01

    La2Zr2O7-SrZrO3 composite thermal barrier coatings (TBCs) were prepared by air plasma spray (APS). The La2Zr2O7-SrZrO3 composite TBCs covered with calcium-magnesium-aluminum-silicate (CMAS) powder, as well as the powder mixture of CMAS and spray-dried La2Zr2O7-SrZrO3 composite powder, were heat-treated at 1250 °C in air for 1, 4, 8, and 12 h. The phase constituents and microstructures of the reaction products were characterized by x-ray diffraction, scanning electron microscopy, and energy-dispersive spectroscopy. Experimental results showed that the La2Zr2O7-SrZrO3 composite TBCs had higher CMAS resistance than 8YSZ coating. A dense new layer developed between CMAS and La2Zr2O7-SrZrO3 composite TBCs during interaction, and this new layer consisted mostly of apatite (Ca2La8(SiO4)6O2) and c-ZrO2. The newly developed layer effectively protected the La2Zr2O7-SrZrO3 composite TBCs from further CMAS attack.

  20. Applicability of the ICD-11 proposal for PTSD: a comparison of prevalence and comorbidity rates with the DSM-IV PTSD classification in two post-conflict samples

    PubMed Central

    Stammel, Nadine; Abbing, Eva M.; Heeke, Carina; Knaevelsrud, Christine

    2015-01-01

    Background The World Health Organization recently proposed significant changes to the posttraumatic stress disorder (PTSD) diagnostic criteria in the 11th edition of the International Classification of Diseases (ICD-11). Objective The present study investigated the impact of these changes in two different post-conflict samples. Method Prevalence and rates of concurrent depression and anxiety, socio-demographic characteristics, and indicators of clinical severity according to ICD-11 in 1,075 Cambodian and 453 Colombian civilians exposed to civil war and genocide were compared to those according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV). Results Results indicated significantly lower prevalence rates under the ICD-11 proposal (8.1% Cambodian sample and 44.4% Colombian sample) compared to the DSM-IV (11.2% Cambodian sample and 55.0% Colombian sample). Participants meeting a PTSD diagnosis only under the ICD-11 proposal had significantly lower rates of concurrent depression and a lower concurrent total score (depression and anxiety) compared to participants meeting only DSM-IV diagnostic criteria. There were no significant differences in socio-demographic characteristics and indicators of clinical severity between these two groups. Conclusions The lower prevalence of PTSD according to the ICD-11 proposal in our samples of persons exposed to a high number of traumatic events may counter criticism of previous PTSD classifications to overuse the PTSD diagnosis in populations exposed to extreme stressors. Also another goal, to better distinguish PTSD from comorbid disorders could be supported with our data. PMID:25989951