Sample records for icrp biokinetic model

  1. A biokinetic model for systemic nickel

    DOE PAGES

    Melo, Dunstana; Leggett, Richard Wayne

    2017-01-01

    The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less

  2. A biokinetic model for systemic nickel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melo, Dunstana; Leggett, Richard Wayne

    The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less

  3. The computation of ICRP dose coefficients for intakes of radionuclides with PLEIADES: biokinetic aspects.

    PubMed

    Fell, T P

    2007-01-01

    The ICRP has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public including children and pregnant or lactating women. The calculation of these coefficients conveniently divides into two distinct parts--the biokinetic and dosimetric. This paper gives a brief summary of the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES.

  4. Proposed biokinetic model for phosphorus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne

    2014-06-04

    This paper reviews data related to the biokinetics of phosphorus in the human body and proposes a biokinetic model for systemic phosphorus for use in updated International Commission on Radiological Protection (ICRP) guidance on occupational intake of radionuclides. Compared with the ICRP s current occupational model for phosphorus (Publication 68, 1994) the proposed model provides a more realistic description of the paths of movement of phosphorus in the body and improved consistency with experimental, medical, and environmental data on the time-dependent distribution and retention of phosphorus following uptake to blood. For acute uptake of 32P to blood, the proposed modelmore » yields roughly a 50% decrease in dose estimates for bone surface and red marrow and a 6-fold increase in estimates for liver and kidney compared with the biokinetic model of Publication 68 (applying Publication 68 dosimetric models in both sets of calculations). For acute uptake of 33P to blood, the proposed model yields roughly a 50% increase in dose estimates for bone surface and red marrow and a 7-fold increase in estimates for liver and kidney compared with the model of Publication 68.« less

  5. Development of a computer code to calculate the distribution of radionuclides within the human body by the biokinetic models of the ICRP.

    PubMed

    Matsumoto, Masaki; Yamanaka, Tsuneyasu; Hayakawa, Nobuhiro; Iwai, Satoshi; Sugiura, Nobuyuki

    2015-03-01

    This paper describes the Basic Radionuclide vAlue for Internal Dosimetry (BRAID) code, which was developed to calculate the time-dependent activity distribution in each organ and tissue characterised by the biokinetic compartmental models provided by the International Commission on Radiological Protection (ICRP). Translocation from one compartment to the next is taken to be governed by first-order kinetics, which is formulated by the first-order differential equations. In the source program of this code, the conservation equations are solved for the mass balance that describes the transfer of a radionuclide between compartments. This code is applicable to the evaluation of the radioactivity of nuclides in an organ or tissue without modification of the source program. It is also possible to handle easily the cases of the revision of the biokinetic model or the application of a uniquely defined model by a user, because this code is designed so that all information on the biokinetic model structure is imported from an input file. The sample calculations are performed with the ICRP model, and the results are compared with the analytic solutions using simple models. It is suggested that this code provides sufficient result for the dose estimation and interpretation of monitoring data. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. A generic biokinetic model for noble gases with application to radon.

    PubMed

    Leggett, Rich; Marsh, James; Gregoratto, Demetrio; Blanchardon, Eric

    2013-06-01

    To facilitate the estimation of radiation doses from intake of radionuclides, the International Commission on Radiological Protection (ICRP) publishes dose coefficients (dose per unit intake) based on reference biokinetic and dosimetric models. The ICRP generally has not provided biokinetic models or dose coefficients for intake of noble gases, but plans to provide such information for (222)Rn and other important radioisotopes of noble gases in a forthcoming series of reports on occupational intake of radionuclides (OIR). This paper proposes a generic biokinetic model framework for noble gases and develops parameter values for radon. The framework is tailored to applications in radiation protection and is consistent with a physiologically based biokinetic modelling scheme adopted for the OIR series. Parameter values for a noble gas are based largely on a blood flow model and physical laws governing transfer of a non-reactive and soluble gas between materials. Model predictions for radon are shown to be consistent with results of controlled studies of its biokinetics in human subjects.

  7. Basis for the ICRP’s updated biokinetic model for carbon inhaled as CO 2

    DOE PAGES

    Leggett, Richard W.

    2017-03-02

    Here, the International Commission on Radiological Protection (ICRP) is updating its biokinetic and dosimetric models for occupational intake of radionuclides (OIR) in a series of reports called the OIR series. This paper describes the basis for the ICRP's updated biokinetic model for inhalation of radiocarbon as carbon dioxide (CO 2) gas. The updated model is based on biokinetic data for carbon isotopes inhaled as carbon dioxide or injected or ingested as bicarbonatemore » $$({{{\\rm{HCO}}}_{3}}^{-}).$$ The data from these studies are expected to apply equally to internally deposited (or internally produced) carbon dioxide and bicarbonate based on comparison of excretion rates for the two administered forms and the fact that carbon dioxide and bicarbonate are largely carried in a common form (CO 2–H$${{{\\rm{CO}}}_{3}}^{-})$$ in blood. Compared with dose estimates based on current ICRP biokinetic models for inhaled carbon dioxide or ingested carbon, the updated model will result in a somewhat higher dose estimate for 14C inhaled as CO 2 and a much lower dose estimate for 14C ingested as bicarbonate.« less

  8. Basis for the ICRP’s updated biokinetic model for carbon inhaled as CO 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard W.

    Here, the International Commission on Radiological Protection (ICRP) is updating its biokinetic and dosimetric models for occupational intake of radionuclides (OIR) in a series of reports called the OIR series. This paper describes the basis for the ICRP's updated biokinetic model for inhalation of radiocarbon as carbon dioxide (CO 2) gas. The updated model is based on biokinetic data for carbon isotopes inhaled as carbon dioxide or injected or ingested as bicarbonatemore » $$({{{\\rm{HCO}}}_{3}}^{-}).$$ The data from these studies are expected to apply equally to internally deposited (or internally produced) carbon dioxide and bicarbonate based on comparison of excretion rates for the two administered forms and the fact that carbon dioxide and bicarbonate are largely carried in a common form (CO 2–H$${{{\\rm{CO}}}_{3}}^{-})$$ in blood. Compared with dose estimates based on current ICRP biokinetic models for inhaled carbon dioxide or ingested carbon, the updated model will result in a somewhat higher dose estimate for 14C inhaled as CO 2 and a much lower dose estimate for 14C ingested as bicarbonate.« less

  9. Reliability of a new biokinetic model of zirconium in internal dosimetry: part I, parameter uncertainty analysis.

    PubMed

    Li, Wei Bo; Greiter, Matthias; Oeh, Uwe; Hoeschen, Christoph

    2011-12-01

    The reliability of biokinetic models is essential in internal dose assessments and radiation risk analysis for the public, occupational workers, and patients exposed to radionuclides. In this paper, a method for assessing the reliability of biokinetic models by means of uncertainty and sensitivity analysis was developed. The paper is divided into two parts. In the first part of the study published here, the uncertainty sources of the model parameters for zirconium (Zr), developed by the International Commission on Radiological Protection (ICRP), were identified and analyzed. Furthermore, the uncertainty of the biokinetic experimental measurement performed at the Helmholtz Zentrum München-German Research Center for Environmental Health (HMGU) for developing a new biokinetic model of Zr was analyzed according to the Guide to the Expression of Uncertainty in Measurement, published by the International Organization for Standardization. The confidence interval and distribution of model parameters of the ICRP and HMGU Zr biokinetic models were evaluated. As a result of computer biokinetic modelings, the mean, standard uncertainty, and confidence interval of model prediction calculated based on the model parameter uncertainty were presented and compared to the plasma clearance and urinary excretion measured after intravenous administration. It was shown that for the most important compartment, the plasma, the uncertainty evaluated for the HMGU model was much smaller than that for the ICRP model; that phenomenon was observed for other organs and tissues as well. The uncertainty of the integral of the radioactivity of Zr up to 50 y calculated by the HMGU model after ingestion by adult members of the public was shown to be smaller by a factor of two than that of the ICRP model. It was also shown that the distribution type of the model parameter strongly influences the model prediction, and the correlation of the model input parameters affects the model prediction to a

  10. A biokinetic model for {sup 137}Cs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melo, D.R.; Lipsztein, J.L.; Oliveira, C.A.N.

    1997-08-01

    An improved biokinetic model for {sup 137}Cs in humans was developed based on an analysis of data obtained from individuals internally contaminated during an accident in Goiania, Brazil, and other data. Seventeen children (ten girls and seven boys 1-10 y old), ten adolescents (four females and six males), and thirty adults, (fifteen females and fifteen males) contaminated in the accident in Goiania contributed to this study. {sup 137}Cs retention was determined through periodic measurements in a whole-body counter. In addition to the data on {sup 137}Cs retention from these individuals, data from a study on the metabolism of {sup 137}Csmore » in immature, adult, and aged Beagle dogs and data from the literature were used in the formulation of the {sup 137}Cs biokinetic model presented. Mathematically, the retention of cesium is described by three exponential terms, and the retention model is based on a step function of body weight. When the ICRP Publication 56 model for cesium was compared to the model suggested in this paper, it was determined that the ICRP model predicts lower effective doses in 5-y-old children and higher effective doses in infants, adolescents, and adults.« less

  11. Age and gender specific biokinetic model for strontium in humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shagina, N. B.; Tolstykh, E. I.; Degteva, M. O.

    A biokinetic model for strontium in humans is necessary for quantification of internal doses due to strontium radioisotopes. The ICRP-recommended biokinetic model for strontium has limitation for use in a population study, because it is not gender specific and does not cover all age ranges. The extensive Techa River data set on 90Sr in humans (tens of thousands of measurements) is a unique source of data on long-term strontium retention for men and women of all ages at intake. These, as well as published data, were used for evaluation of age- and gender-specific parameters for a new compartment biokinetic modelmore » for strontium (Sr-AGe model). The Sr-AGe model has similar structure as the ICRP model for the alkaline earth elements. The following parameters were mainly reevaluated: gastro-intestinal absorption and parameters related to the processes of bone formation and resorption defining calcium and strontium transfers in skeletal compartments. The Sr-AGe model satisfactorily describes available data sets on strontium retention for different kinds of intake (dietary and intravenous) at different ages (0–80 years old) and demonstrates good agreement with data sets for different ethnic groups. The Sr-AGe model can be used for dose assessment in epidemiological studies of general population exposed to ingested strontium radioisotopes.« less

  12. Adaptation of the ICRP publication 66 respiratory tract model to data on plutonium biokinetics for Mayak workers.

    PubMed

    Khokhryakov, V F; Suslova, K G; Vostrotin, V V; Romanov, S A; Eckerman, K F; Krahenbuhl, M P; Miller, S C

    2005-02-01

    The biokinetics of inhaled plutonium were analyzed using compartment models representing their behavior within the respiratory tract, the gastrointestinal tract, and in systemic tissues. The processes of aerosol deposition, particle transport, absorption, and formation of a fixed deposit in the respiratory tract were formulated in the framework of the Human Respiratory Tract Model described in ICRP Publication 66. The values of parameters governing absorption and formation of the fixed deposit were established by fitting the model to the observations in 530 autopsy cases. The influence of smoking on mechanical clearance of deposited plutonium activity was considered. The dependence of absorption on the aerosol transportability, as estimated by in vitro methods (dialysis), was demonstrated. The results of this study were compared to those obtained from an earlier model of plutonium behavior in the respiratory tract, which was based on the same set of autopsy data. That model did not address the early phases of respiratory clearance and hence underestimated the committed lung dose by about 25% for plutonium oxides. Little difference in lung dose was found for nitrate forms.

  13. A biokinetic model for systemic technetium in adult humans

    DOE PAGES

    Leggett, Richard Wayne; Giussani, Augusto

    2015-04-10

    The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99Tm(T 1/2=2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99mTc (T 1/2=6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body formore » use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99Tm or 99mTc to blood.« less

  14. Human biokinetic data and a new compartmental model of zirconium--a tracer study with enriched stable isotopes.

    PubMed

    Greiter, Matthias B; Giussani, Augusto; Höllriegl, Vera; Li, Wei Bo; Oeh, Uwe

    2011-09-01

    Biokinetic models describing the uptake, distribution and excretion of trace elements are an essential tool in nutrition, toxicology, or internal dosimetry of radionuclides. Zirconium, especially its radioisotope (95)Zr, is relevant to radiation protection due to its production in uranium fission and neutron activation of nuclear fuel cladding material. We present a comprehensive set of human data from a tracer study with stable isotopes of zirconium. The data are used to refine a biokinetic model of zirconium. Six female and seven male healthy adult volunteers participated in the study. It includes 16 complete double tracer investigations with oral ingestion and intravenous injection, and seven supplemental investigations. Tracer concentrations were measured in blood plasma and urine collected up to 100 d after tracer administration. The four data sets (two chemical tracer forms in plasma and urine) each encompass 105-240 measured concentration values above detection limits. Total fractional absorption of ingested zirconium was found to be 0.001 for zirconium in citrate-buffered drinking solution and 0.007 for zirconium oxalate solution. Biokinetic models were developed based on the linear first-order kinetic compartmental model approach used by the International Commission on Radiological Protection (ICRP). The main differences of the optimized systemic model of zirconium to the current ICRP model are (1) recycling into the transfer compartment made necessary by the observed tracer clearance from plasma, (2) different parameters related to fractional absorption for each form of the ingested tracer, and (3) a physiologically based excretion pathway to urine. The study considerably expands the knowledge on the biokinetics of zirconium, which was until now dominated by data from animal studies. The proposed systemic model improves the existing ICRP model, yet is based on the same principles and fits well into the ICRP radiation protection approach. Copyright © 2011

  15. A generic biokinetic model for noble gases with application to radon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Marsh, James; Gregoratto, Demetrio

    The International Commission for Radiological Protection (ICRP) currently uses a dose conversion coefficient to calculate effective dose per unit exposure to radon and its progeny. The coefficient is derived by dividing the detriment associated with unit exposure to radon, as estimated from epidemiological studies, by the detriment per unit effective dose, as estimated mainly from atomic bomb survivor data and animal studies. In a recent statement the ICRP indicated that future guidance on exposure to radon and its progeny will be developed in the same way as guidance for any other radionuclide. That is, intake of radon and progeny willmore » be limited on the basis of effective dose coefficients derived from biokinetic and dosimetric models. This paper proposes a biokinetic model for systemic (absorbed) radon for use in the calculation of dose coefficients for inhaled or ingested radon. The model is based largely on physical laws governing transfer of a non-reactive and soluble gas between materials. Model predictions are shown to be consistent with results of controlled studies of the fate of internally deposited radon in human subjects.« less

  16. A generic biokinetic model for carbon-14 labelled compounds

    NASA Astrophysics Data System (ADS)

    Manger, Ryan Paul

    Carbon-14, a radioactive nuclide, is used in many industrial applications. Due to its wide range of uses in industry, many workers are at risk of accidental internal exposure to 14C. Being a low energy beta emitter, 14C is not a significant external radiation hazard, but the internal consequences posed by 14C are important, especially because of its long half life of 5730 years [46]. The current biokinetic model recommended by the International Commission on Radiological Protection (ICRP) is a conservative estimate of how radiocarbon is treated by the human body. The ICRP generic radiocarbon model consists of a single compartment representing the entire human body. This compartment has a biological half life of 40 days yielding an effective dose coefficient of 5.8x10-10 Sv B q-1 [44, 45, 49, 53, 54]. This overestimates the dose of all radiocarbon compounds that have been studied [96]. An improved model has been developed that includes and alimentary tract, a urinary bladder, CO2 model, and an "Other" compartment used to model systemic tissues. The model can be adapted to replicate any excretion curve and excretion pattern. In addition, the effective dose coefficient produced by the updated model is near the mean effective dose coefficient of carbon compounds that have been considered in this research. The major areas of improvement are: more anatomically significant, a less conservative dose coefficient, and the ability to manipulate the model for known excretion data. Due to the wide variety of carbon compounds, it is suggested that specific biokinetic models be implemented for known radiocarbon substances. If the source of radiocarbon is dietary, then the physiologically based model proposed by Whillans [102] that splits all ingested radiocarbon compounds into carbohydrates, fats, and proteins should be used.

  17. ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Marsh, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Blanchardon, E; Gregoratto, D; Harrison, J D

    2017-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988) and Publication 68 (ICRP, 1994). In addition, new data are now available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. OIR Part 1 has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. OIR Part 2 (ICRP, 2016), this current publication and upcoming publications in the OIR series (Parts 4 and 5) provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv Bq−1 intake) for inhalation and ingestion, tables of committed effective dose

  18. Biokinetic data and models for occupational intake of lanthanoids

    DOE PAGES

    Leggett, Richard Wayne; Ansoborlo, Eric; Bailey, Michael; ...

    2014-05-12

    The lanthanoid (or lanthanide) chemical elements comprise fifteen elements with atomic numbers 57 (lanthanum) through 71 (lutetium). This paper reviews data related to the biological behavior of these elements in the human body and proposes biokinetic models for application to occupational intake of radio-lanthanoids. Generic (element-independent) absorption rates from the respiratory and alimentary tracts to blood are proposed. The proposed systemic models are largely generic but include some element-specific parameter values to reflect regular changes with ionic radius in certain aspects of the behavior of the lanthanoids. This work was performed within the internal dosimetry task group (INDOS) of Committeemore » 2 of the International Commission on Radiological Protection (ICRP).« less

  19. Current activities in the ICRP concerning estimation of radiation doses to patients from radiopharmaceuticals for diagnostic use

    NASA Astrophysics Data System (ADS)

    Mattsson, S.; Johansson, L.; Leide-Svegborn, S.; Liniecki, J.; Nosske, D.; Riklund, K.; Stabin, M.; Taylor, D.

    2011-09-01

    A Task Group within the ICRP Committees 2 and 3 is continuously working to improve absorbed dose estimates to patients investigated with radiopharmaceuticals. The work deals with reviews of the literature, initiation of new or complementary studies of the biokinetics of a compound and dose estimates. Absorbed dose calculations for organs and tissues have up to now been carried out using the MIRD formalism. There is still a lack of necessary biokinetic data from measurements in humans. More time series obtained by nuclear medicine imaging techniques such as whole-body planar gamma-camera imaging, SPECT or PET are highly desirable for this purpose. In 2008, a new addendum to ICRP Publication 53 was published under the name of ICRP Publication 106 containing biokinetic data and absorbed dose information to organs and tissues of patients of various ages for radiopharmaceuticals in common use. That report also covers a number of generic models and realistic maximum models covering other large groups of substances (e.g. "123I-brain receptor substances"). Together with ICRP Publication 80, most radiopharmaceuticals in clinical use at the time of publication were covered except the radioiodine labeled compounds for which the ICRP dose estimates are still found in Publication 53. There is an increasing use of new radiopharmaceuticals, especially PET-tracers and the TG has recently finished its work with biokinetic and dosimetric data for 18F-FET, 18F-FLT and 18F-choline. The work continues now with new data for 11C-raclopride, 11C-PiB and 123I-ioflupan as well as re-evaluation of published data for 82Rb-chloride, 18F-fluoride and radioiodide. This paper summarises published ICRP-information on dose to patients from radiopharmaceuticals and gives some preliminary data for substances under review.

  20. ICRP Publication 134: Occupational Intakes of Radionuclides: Part 2.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Ansoborlo, E; Giussani, A; Bolch, W E; Harrison, J D

    2016-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988b) and Publication 68 (ICRP, 1994b). In addition, new data are available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. Part 1 of the OIR series has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. The following publications in the OIR series (Parts 2–5) will provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv per Bq intake) for inhalation and ingestion, tables of committed effective dose per content (Sv per Bq

  1. Inhalation dose assessment of indoor radon progeny using biokinetic and dosimetric modeling and its application to Jordanian population.

    PubMed

    Al-Jundi, J; Li, W B; Abusini, M; Tschiersch, J; Hoeschen, C; Oeh, U

    2011-06-01

    High indoor radon concentrations in Jordan result in internal exposures of the residents due to the inhalation of radon and its short-lived progeny. It is therefore important to quantify the annual effective dose and further the radiation risk to the radon exposure. This study describes the methodology and the biokinetic and dosimetric models used for calculation of the inhalation doses exposed to radon progeny. The regional depositions of aerosol particles in the human respiratory tract were firstly calculated. For the attached progeny, the activity median aerodynamic diameters of 50 nm, 230 nm and 2500 nm were chosen to represent the nucleation, accumulation and coarse modes of the aerosol particles, respectively. For the unattached progeny, the activity median thermodynamic diameter of 1 nm was chosen to represent the free progeny nuclide in the room air. The biokinetic models developed by the International Commission on Radiological Protection (ICRP) were used to calculate the nuclear transformations of radon progeny in the human body, and then the dosimetric model was applied to estimate the organ equivalent doses and the effective doses with the specific effective energies derived from the mathematical anthropomorphic phantoms. The dose conversion coefficient estimated in this study was 15 mSv WLM(-1) which was in the range of the values of 6-20 mSv WLM(-1) reported by other investigators. Implementing the average indoor radon concentration in Jordan, the annual effective doses were calculated to be 4.1 mSv y(-1) and 0.08 mSv y(-1) due to the inhalation of radon progeny and radon gas, respectively. The total annual effective dose estimated for Jordanian population was 4.2 mSv y(-1). This high annual effective dose calculated by the dosimetric approach using ICRP biokinetic and dosimetric models resulted in an increase of a factor of two in comparison to the value by epidemiological study. This phenomenon was presented by the ICRP in its new published

  2. The work of the ICRP dose calculational task group: Issues in implementation of the ICRP dosimetric methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, K.F.

    Committee 2 of the International Commission on Radiological Protection (ICRP) has had efforts underway to provide the radiation protection community with age-dependent dose coefficients, i.e.g, the dose per unit intake. The Task Group on Dose Calculations, chaired by the author, is responsible for the computation of these coefficients. The Task Group, formed in 1974 to produce ICRP Publication 30, is now international in its membership and its work load has been distributed among the institutions represented on the task group. This paper discusses: (1) recent advances in biokinetic modeling; (2) the recent changes in the dosimetric methodology; (3) the novelmore » computational problems with some of the ICRP quantities; and (4) quality assurance issues which the Task Group has encountered. Potential future developments of the dosimetric framework which might strengthen the relationships with the emerging understanding of radiation risk will also be discussed.« less

  3. Development of the Plutonium-DTPA Biokinetic Model.

    PubMed

    Konzen, Kevin; Brey, Richard

    2015-06-01

    Estimating radionuclide intakes from bioassays following chelation treatment presents a challenge to the dosimetrist due to the observed excretion enhancement of the particular radionuclide of concern where no standard biokinetic model exists. This document provides a Pu-DTPA biokinetic model that may be used for making such determination for plutonium intakes. The Pu-DTPA biokinetic model is intended to supplement the standard recommended biokinetic models. The model was used to evaluate several chelation strategies that resulted in providing recommendations for effective treatment. These recommendations supported early treatment for soluble particle inhalations and an initial 3-day series of DTPA treatments for wounds. Several late chelation strategies were also compared where reduced treatment frequencies proved to be as effective as multiple treatments. The Pu-DTPA biokinetic model can be used to assist in estimating initial intakes of transuranic radionuclides and for studying the effects of different treatment strategies.

  4. Development of the Plutonium-DTPA biokinetic model

    DOE PAGES

    Konzen, Kevin; Brey, Richard

    2015-06-01

    Estimating radionuclide intakes from bioassays following chelation treatment presents a challenge to the dosimetrist due to the observed excretion enhancement of the particular radionuclide of concern, where no standard biokinetic model exists. This document provides a Pu-DTPA biokinetic model that may be used for making such determination for plutonium intakes. The Pu-DTPA biokinetic model is intended to supplement the standard recommended biokinetic models. The model was used to evaluate several chelation strategies that resulted in providing recommendations for effective treatment. These recommendations supported early treatment for soluble particle inhalations and an initial 3-day treatment series of DTPA treatments for wounds.more » Several late chelation strategies were also compared where reduced treatment frequencies proved to be as effective as multiple treatments. Furthermore, the Pu-DTPA biokinetic model can be used to assist in estimating initial intakes of transuranic radionuclides, and for studying the effects of different treatment strategies.« less

  5. Reliability of a new biokinetic model of zirconium in internal dosimetry: part II, parameter sensitivity analysis.

    PubMed

    Li, Wei Bo; Greiter, Matthias; Oeh, Uwe; Hoeschen, Christoph

    2011-12-01

    The reliability of biokinetic models is essential for the assessment of internal doses and a radiation risk analysis for the public and occupational workers exposed to radionuclides. In the present study, a method for assessing the reliability of biokinetic models by means of uncertainty and sensitivity analysis was developed. In the first part of the paper, the parameter uncertainty was analyzed for two biokinetic models of zirconium (Zr); one was reported by the International Commission on Radiological Protection (ICRP), and one was developed at the Helmholtz Zentrum München-German Research Center for Environmental Health (HMGU). In the second part of the paper, the parameter uncertainties and distributions of the Zr biokinetic models evaluated in Part I are used as the model inputs for identifying the most influential parameters in the models. Furthermore, the most influential model parameter on the integral of the radioactivity of Zr over 50 y in source organs after ingestion was identified. The results of the systemic HMGU Zr model showed that over the first 10 d, the parameters of transfer rates between blood and other soft tissues have the largest influence on the content of Zr in the blood and the daily urinary excretion; however, after day 1,000, the transfer rate from bone to blood becomes dominant. For the retention in bone, the transfer rate from blood to bone surfaces has the most influence out to the endpoint of the simulation; the transfer rate from blood to the upper larger intestine contributes a lot in the later days; i.e., after day 300. The alimentary tract absorption factor (fA) influences mostly the integral of radioactivity of Zr in most source organs after ingestion.

  6. Historical perspective on lead biokinetic models.

    PubMed Central

    Rabinowitz, M

    1998-01-01

    A historical review of the development of biokinetic model of lead is presented. Biokinetics is interpreted narrowly to mean only physiologic processes happening within the body. Proceeding chronologically, for each epoch, the measurements of lead in the body are presented along with mathematical models in an attempt to trace the convergence of observations from two disparate fields--occupational medicine and radiologic health--into some unified models. Kehoe's early balance studies and the use of radioactive lead tracers are presented. The 1960s saw the joint application of radioactive lead techniques and simple compartmental kinetic models used to establish the exchange rates and residence times of lead in body pools. The applications of stable isotopes to questions of the magnitudes of respired and ingested inputs required the development of a simple three-pool model. During the 1980s more elaborate models were developed. One of their key goals was the establishment of the dose-response relationship between exposure to lead and biologic precursors of adverse health effects. PMID:9860905

  7. Comparison of observed lung retention and urinary excretion of thorium workers and members of the public in India with the values predicted by the ICRP biokinetic model.

    PubMed

    Jaiswal, D D; Singh, I S; Nair, Suma; Dang, H S; Garg, S P; Pradhan, A S

    2004-01-01

    The daily intake of natural Th and its contents in lungs, skeleton and liver of an Indian adult population group were estimated using radiochemical neutron activation analysis (RNAA) technique. These data on daily intake (through inhalation and ingestion) were used to compute Th contents in lungs and other systemic organs such as skeleton and liver using the new human respiratory tract model (HRTM) and the new biokinetic model of Th. The theoretically computed Th contents in lungs, skeleton and liver of an average Indian adult are 2.56, 4.00 and 0.17 microg, respectively which are comparable with the corresponding experimentally measured values of 4.31, 3.45 and 0.14 microg in an urban population group living in Mumbai. The measured lung contents of Th in a group of five occupational workers were used to compute their total body Th contents and the corresponding daily urinary excretions. The computed total body contents and daily urinary excretions of Th in the five subjects compared favourably with their measured values. These studies, thus, validate the new biokinetic model of Th in natural as well as in occupational exposures in Indian conditions.

  8. a Biokinetic Model for CESIUM-137 in the Fetus

    NASA Astrophysics Data System (ADS)

    Jones, Karen Lynn

    1995-01-01

    Previously, there was no method to determine the dose to the embryo, fetus, fetal organs or placenta from radionuclides within the embryo, fetus, or placenta. In the past, the dose to the fetus was assumed to be equivalent to the dose to the uterus. Watson estimated specific absorbed fractions from various maternal organs to the uterine contents which included the fetus, placenta, and amniotic fluid and Sikov estimated the absorbed dose to the embryo/fetus after assuming 1 uCi of radioactivity was made available to the maternal blood.^{1,2} However, this method did not allow for the calculation of a dose to individual fetal organs or the placenta. The radiation dose to the embryo or fetus from Cs-137 in the fetus and placenta due to a chronic ingestion by the mother was determined. The fraction of Cs-137 in the maternal plasma crossing the placenta to the fetal plasma was estimated. The absorbed dose from Cs-137 in each modelled fetal organ was estimated. Since there has been more research regarding potassium in the human body, and particularly in the pregnant woman, a biokinetic model for potassium was developed first and used as a basis and confirmation of the cesium model. Available pertinent information in physiology, embryology, biokinetics, and radiation dosimetry was utilized. Due to the rapid growth of the fetus and placenta, the pregnancy was divided into four gestational periods. The numerous physiological changes that occurred during pregnancy were considered and an appropriate biokinetic model was developed for each of the gestational periods. The amount of cesium in the placenta, embryo, and fetus was estimated for each period. The dose to the fetus from cesium deposited in the embryo or fetus and in the placenta was determined for each period using Medical Internal Radiation Dosimetry (MIRD) methodology. An uncertainty analysis was also performed to account for the variability of the parameters in the biokinetic model based on the experimental data

  9. Preclinical Biokinetic Modelling of Tc-99m Radiophamaceuticals Obtained from Semi-Automatic Image Processing.

    PubMed

    Cornejo-Aragón, Luz G; Santos-Cuevas, Clara L; Ocampo-García, Blanca E; Chairez-Oria, Isaac; Diaz-Nieto, Lorenza; García-Quiroz, Janice

    2017-01-01

    The aim of this study was to develop a semi automatic image processing algorithm (AIPA) based on the simultaneous information provided by X-ray and radioisotopic images to determine the biokinetic models of Tc-99m radiopharmaceuticals from quantification of image radiation activity in murine models. These radioisotopic images were obtained by a CCD (charge couple device) camera coupled to an ultrathin phosphorous screen in a preclinical multimodal imaging system (Xtreme, Bruker). The AIPA consisted of different image processing methods for background, scattering and attenuation correction on the activity quantification. A set of parametric identification algorithms was used to obtain the biokinetic models that characterize the interaction between different tissues and the radiopharmaceuticals considered in the study. The set of biokinetic models corresponded to the Tc-99m biodistribution observed in different ex vivo studies. This fact confirmed the contribution of the semi-automatic image processing technique developed in this study.

  10. A recycling model of the biokinetics of systemic tellurium.

    PubMed

    Giussani, Augusto

    2014-11-01

    To develop a compartmental model of the systemic biokinetics of tellurium required for calculating the internal dose and interpreting bioassay measurements after incorporation of radioactive tellurium. The compartmental model for tellurium was developed with the software SAAM II v. 2.0 (©The Epsilon Group, Charlottesville, Virginia, USA). Model parameters were determined on the basis of published retention and excretion data in humans and animals. The model consists of two blood compartments, one compartment each for liver, kidneys, thyroid, four compartments for bone tissues and a generic compartment for the soft tissues. The model predicts a rapid urinary excretion of systemic tellurium: 45% in the first 24 h and 84% after 50 d. Faecal excretion amounts to 0.4% after 3 d and 9% after 50 d. Whole body retention is 55% after one day, and 2.8% after 100 d. These values as well as the retained fractions in the single organs are reasonably consistent with the available human and animal data (studies with swine and guinea pigs). The proposed model gives a realistic description of the available biokinetic data for tellurium and will be adopted by the International Commission on Radiological Protection for applications in internal dosimetry.

  11. Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms

    NASA Astrophysics Data System (ADS)

    Tat Nguyen, Thang; Yeom, Yeon Soo; Kim, Han Sung; Wang, Zhao Jun; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Chung, Beom Sun

    2015-11-01

    The dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.

  12. An age-specific biokinetic model for iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne

    This study reviews age-specific biokinetic data for iodine in humans and extends to pre-adult ages the baseline parameter values of the author’s previously published model for systemic iodine in adult humans. Compared with the ICRP’s current age-specific model for iodine introduced in Publication 56 (1989), the present model provides a more detailed description of the behavior of iodine in the human body; predicts greater cumulative (integrated) activity in the thyroid for short-lived isotopes of iodine; predicts similar cumulative activity in the thyroid for isotopes with half-time greater than a few hours; and, for most iodine isotopes, predicts much greater cumulativemore » activity in salivary glands, stomach wall, liver, and kidneys.« less

  13. An age-specific biokinetic model for iodine

    DOE PAGES

    Leggett, Richard Wayne

    2017-10-26

    This study reviews age-specific biokinetic data for iodine in humans and extends to pre-adult ages the baseline parameter values of the author’s previously published model for systemic iodine in adult humans. Compared with the ICRP’s current age-specific model for iodine introduced in Publication 56 (1989), the present model provides a more detailed description of the behavior of iodine in the human body; predicts greater cumulative (integrated) activity in the thyroid for short-lived isotopes of iodine; predicts similar cumulative activity in the thyroid for isotopes with half-time greater than a few hours; and, for most iodine isotopes, predicts much greater cumulativemore » activity in salivary glands, stomach wall, liver, and kidneys.« less

  14. An image-based skeletal tissue model for the ICRP reference newborn

    NASA Astrophysics Data System (ADS)

    Pafundi, Deanna; Lee, Choonsik; Watchman, Christopher; Bourke, Vincent; Aris, John; Shagina, Natalia; Harrison, John; Fell, Tim; Bolch, Wesley

    2009-07-01

    Hybrid phantoms represent a third generation of computational models of human anatomy needed for dose assessment in both external and internal radiation exposures. Recently, we presented the first whole-body hybrid phantom of the ICRP reference newborn with a skeleton constructed from both non-uniform rational B-spline and polygon-mesh surfaces (Lee et al 2007 Phys. Med. Biol. 52 3309-33). The skeleton in that model included regions of cartilage and fibrous connective tissue, with the remainder given as a homogenous mixture of cortical and trabecular bone, active marrow and miscellaneous skeletal tissues. In the present study, we present a comprehensive skeletal tissue model of the ICRP reference newborn to permit a heterogeneous representation of the skeleton in that hybrid phantom set—both male and female—that explicitly includes a delineation of cortical bone so that marrow shielding effects are correctly modeled for low-energy photons incident upon the newborn skeleton. Data sources for the tissue model were threefold. First, skeletal site-dependent volumes of homogeneous bone were obtained from whole-cadaver CT image analyses. Second, selected newborn bone specimens were acquired at autopsy and subjected to micro-CT image analysis to derive model parameters of the marrow cavity and bone trabecular 3D microarchitecture. Third, data given in ICRP Publications 70 and 89 were selected to match reference values on total skeletal tissue mass. Active marrow distributions were found to be in reasonable agreement with those given previously by the ICRP. However, significant differences were seen in total skeletal and site-specific masses of trabecular and cortical bone between the current and ICRP newborn skeletal tissue models. The latter utilizes an age-independent ratio of 80%/20% cortical and trabecular bone for the reference newborn. In the current study, a ratio closer to 40%/60% is used based upon newborn CT and micro-CT skeletal image analyses. These

  15. Reliability of Current Biokinetic and Dosimetric Models for Radionuclides: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Eckerman, Keith F; Meck, Robert A.

    2008-10-01

    This report describes the results of a pilot study of the reliability of the biokinetic and dosimetric models currently used by the U.S. Nuclear Regulatory Commission (NRC) as predictors of dose per unit internal or external exposure to radionuclides. The study examines the feasibility of critically evaluating the accuracy of these models for a comprehensive set of radionuclides of concern to the NRC. Each critical evaluation would include: identification of discrepancies between the models and current databases; characterization of uncertainties in model predictions of dose per unit intake or unit external exposure; characterization of variability in dose per unit intakemore » or unit external exposure; and evaluation of prospects for development of more accurate models. Uncertainty refers here to the level of knowledge of a central value for a population, and variability refers to quantitative differences between different members of a population. This pilot study provides a critical assessment of models for selected radionuclides representing different levels of knowledge of dose per unit exposure. The main conclusions of this study are as follows: (1) To optimize the use of available NRC resources, the full study should focus on radionuclides most frequently encountered in the workplace or environment. A list of 50 radionuclides is proposed. (2) The reliability of a dose coefficient for inhalation or ingestion of a radionuclide (i.e., an estimate of dose per unit intake) may depend strongly on the specific application. Multiple characterizations of the uncertainty in a dose coefficient for inhalation or ingestion of a radionuclide may be needed for different forms of the radionuclide and different levels of information of that form available to the dose analyst. (3) A meaningful characterization of variability in dose per unit intake of a radionuclide requires detailed information on the biokinetics of the radionuclide and hence is not feasible for many

  16. Comparisons of calculated respiratory tract deposition of particles based on the NCRP/ITRI model and the new ICRP66 model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeh, Hsu-Chi; Phalen, R.F.; Chang, I.

    1995-12-01

    The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Althoughmore » this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny ({approximately} 1 nm) to particles larger than 100 {mu}m. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar.« less

  17. Strontium biokinetic model for the pregnant woman and fetus: application to Techa River studies.

    PubMed

    Shagina, N B; Fell, T P; Tolstykh, E I; Harrison, J D; Degteva, M O

    2015-09-01

    A biokinetic model for strontium (Sr) for the pregnant woman and fetus (Sr-PWF model) has been developed for use in the quantification of doses from internal radiation exposures following maternal ingestion of Sr radioisotopes before or during pregnancy. The model relates in particular to the population of the Techa River villages exposed to significant amounts of ingested Sr radioisotopes as a result of releases of liquid radioactive wastes from the Mayak plutonium production facility (Russia) in the early 1950s. The biokinetic model for Sr metabolism in the pregnant woman was based on a biokinetic model for the adult female modified to account for changes in mineral metabolism during pregnancy. The model for non-pregnant females of all ages was developed earlier with the use of extensive data on (90)Sr-body measurements in the Techa Riverside residents. To determine changes in model parameter values to take account of changing mineral metabolism during pregnancy, data from longitudinal studies of calcium homeostasis during human pregnancy were analysed and applied. Exchanges between maternal and fetal circulations and retention in fetal skeleton and soft tissues were modelled as adaptations of previously published models, taking account of data on Sr and calcium (Ca) metabolism obtained in Russia (Southern Urals and Moscow) relating to dietary calcium intakes, calcium contents in maternal and fetal skeletons and strontium transfer to the fetus. The model was validated using independent data on (90)Sr in the fetal skeleton from global fallout as well as unique data on (90)Sr-body burden in mothers and their still-born children for Techa River residents. While the Sr-PWF model has been developed specifically for ingestion of Sr isotopes by Techa River residents, it is also more widely applicable to maternal ingestion of Sr radioisotopes at different times before and during pregnancy and different ages of pregnant women in a general population.

  18. Internal dose assessment of 210Po using biokinetic modeling and urinary excretion measurement.

    PubMed

    Li, Wei Bo; Gerstmann, Udo; Giussani, Augusto; Oeh, Uwe; Paretzke, Herwig G

    2008-02-01

    The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 ((210)Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of (210)Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of (210)Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 x 10(-8) (1.4 x 10(-7)) Sv Bq(-1), 2.0 x 10(-7) (9.6 x 10(-7)) Sv Bq(-1) over 10 days, 5.2 x 10(-7) (2.0 x 10(-6)) Sv Bq(-1) over 30 days and 1.0 x 10(-6) (3.0 x 10(-6)) Sv Bq(-1) over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of (210)Po are 1.1 x 10(-3) (1.0 x 10(-4)) on day 1, 2.0 x 10(-3) (1.9 x 10(-4)) on day 10, 1.3 x 10(-3) (1.7 x 10(-4)) on day 30 and 3.6 x 10(-4) (8.3 x 10(-5)) Bq d(-1) on day 100, respectively. The resulting committed effective doses range from 2.1 x 10(-3) to 1.7 x 10(-2) mSv by an assumption of ingestion and from 5.5 x 10(-2) to 4.5 x 10(-1) mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the kidneys and the liver were considered as the critical organs. Assuming a

  19. Critical review of membrane bioreactor models--part 1: biokinetic and filtration models.

    PubMed

    Naessens, W; Maere, T; Nopens, I

    2012-10-01

    Membrane bioreactor technology exists for a couple of decades, but has not yet overwhelmed the market due to some serious drawbacks of which operational cost due to fouling is the major contributor. Knowledge buildup and optimisation for such complex systems can significantly benefit from mathematical modelling. In this paper, the vast literature on modelling MBR biokinetics and filtration is critically reviewed. It was found that models cover the wide range of empirical to detailed mechanistic descriptions and have mainly been used for knowledge development and to a lesser extent for system optimisation/control. Moreover, studies are still predominantly performed at lab or pilot scale. Trends are discussed, knowledge gaps identified and interesting routes for further research suggested. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. The Role of Extracellular Fluid in Biokinetic Modeling

    DOE PAGES

    Miller, Guthrie; Klumpp, John A.; Melo, Dunstana; ...

    2017-12-01

    Here, the pharmacokinetic equations of Pierson et al. describing the behavior of bromide in rat provide a general approach to the modeling of extracellular fluid (ECF). The movement of material into ECF spaces is rapid and is completely characterized by tissue volumes and vascular flow rates to and from a tissue, the volumes of the tissue, and the ECF associated with the tissue. Early-time measurements are needed to characterize ECF. Measurements of DTPA disappearance from plasma by Wedeking et al. are discussed as an example of such measurements. In any biokinetic model, the fastest transfer rates are not determinable withmore » the usual datasets, and if determined empirically, these rates will have very large and highly correlated uncertainties, so particular values of these rates, even though the model fits the available data, are not significant. A pharmacokinetic front-end provides values for these fast rates. An example of such a front-end for a 200–g rat is given.« less

  1. Letter to the Editor: Appropriate selection of dose coefficients in radiological assessments: C-14 and Cl-36: response to the letter of G Smith and M Thorne (2015 J. Radiol. Prot. 35 737-40)

    DOE PAGES

    Harrison, John D.; Leggett, Richard Wayne

    2016-01-01

    This letter to the editor of Journal of Radiological Protection is in response to a letter to the editor from G. M. Smith and M. C. Thorne of Great Britain concerning the appropriate selection of dose coefficients for ingested carbon-14 and chlorine-36, two of the most important long-lived components of radioactive wastes. Smith and Thorne argue that current biokinetic models of the International Commission on Radiological Protection (ICRP) for carbon and chlorine are overly cautious models from the standpoint of radiation dose estimates for C-14 and Cl-36, and that more realistic models are needed for evaluation of the hazards ofmore » these radionuclides in nuclear wastes. We (Harrison and Leggett) point out that new biokinetic models for these and other elements (developed at ORNL) will soon appear in ICRP Publications. These new models generally are considerably more realistic than current ICRP models. Here, examples are given for C-14 inhaled as carbon dioxide or ingested in water as bicarbonate, carbonate, or carbon dioxide.« less

  2. Evaluation of radiation dose to anthropomorphic paediatric models from positron-emitting labelled tracers

    NASA Astrophysics Data System (ADS)

    Xie, Tianwu; Zaidi, Habib

    2014-03-01

    PET uses specific molecules labelled with positron-emitting radionuclides to provide valuable biochemical and physiological information. However, the administration of radiotracers to patients exposes them to low-dose ionizing radiation, which is a concern in the paediatric population since children are at a higher cancer risk from radiation exposure than adults. Therefore, radiation dosimety calculations for commonly used positron-emitting radiotracers in the paediatric population are highly desired. We evaluate the absorbed dose and effective dose for 19 positron-emitting labelled radiotracers in anthropomorphic paediatric models including the newborn, 1-, 5-, 10- and 15-year-old male and female. This is achieved using pre-calculated S-values of positron-emitting radionuclides of UF-NCI paediatric phantoms and published biokinetic data for various radiotracers. The influence of the type of anthropomorphic model, tissue weight factors and direct human- versus mouse-derived biokinetic data on the effective dose for paediatric phantoms was also evaluated. In the case of 18F-FDG, dosimetry calculations of reference paediatric patients from various dose regimens were also calculated. Among the considered radiotracers, 18F-FBPA and 15O-water resulted in the highest and lowest effective dose in the paediatric phantoms, respectively. The ICRP 103 updated tissue-weighting factors decrease the effective dose in most cases. Substantial differences of radiation dose were observed between direct human- versus mouse-derived biokinetic data. Moreover, the effect of using voxel- versus MIRD-type models on the calculation of the effective dose was also studied. The generated database of absorbed organ dose and effective dose for various positron-emitting labelled radiotracers using new generation computational models and the new ICRP tissue-weighting factors can be used for the assessment of radiation risks to paediatric patients in clinical practice. This work also contributes

  3. Calibration of hydrodynamic behavior and biokinetics for TOC removal modeling in biofilm reactors under different hydraulic conditions.

    PubMed

    Zeng, Ming; Soric, Audrey; Roche, Nicolas

    2013-09-01

    In this study, total organic carbon (TOC) biodegradation was simulated by GPS-X software in biofilm reactors with carriers of plastic rings and glass beads under different hydraulic conditions. Hydrodynamic model by retention time distribution and biokinetic measurement by in-situ batch test served as two significant parts of model calibration. Experimental results showed that TOC removal efficiency was stable in both media due to the enough height of column, although the actual hydraulic volume changed during the variation of hydraulic condition. Simulated TOC removal efficiencies were close to experimental ones with low theil inequality coefficient values (below 0.15). Compared with glass beads, more TOC was removed in the filter with plastic rings due to the larger actual hydraulic volume and lower half saturation coefficient in spite of its lower maximum specific growth rate of biofilm, which highlighted the importance of calibrating hydrodynamic behavior and biokinetics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Biokinetic food chain modeling of waterborne selenium pulses into aquatic food chains: Implications for water quality criteria.

    PubMed

    DeForest, David K; Pargee, Suzanne; Claytor, Carrie; Canton, Steven P; Brix, Kevin V

    2016-04-01

    We evaluated the use of biokinetic models to predict selenium (Se) bioaccumulation into model food chains after short-term pulses of selenate or selenite into water. Both periphyton- and phytoplankton-based food chains were modeled, with Se trophically transferred to invertebrates and then to fish. Whole-body fish Se concentrations were predicted based on 1) the background waterborne Se concentration, 2) the magnitude of the Se pulse, and 3) the duration of the Se pulse. The models were used to evaluate whether the US Environmental Protection Agency's (USEPA's) existing acute Se criteria and their recently proposed intermittent Se criteria would be protective of a whole-body fish Se tissue-based criterion of 8.1 μg g(-1) dry wt. Based on a background waterborne Se concentration of 1 μg L(-1) and pulse durations of 1 d and 4 d, the Se pulse concentrations predicted to result in a whole-body fish Se concentration of 8.1 μg g(-1) dry wt in the most conservative model food chains were 144 and 35 μg L(-1), respectively, for selenate and 57 and 16 μg L(-1), respectively, for selenite. These concentrations fall within the range of various acute Se criteria recommended by the USEPA based on direct waterborne toxicity, suggesting that these criteria may not always be protective against bioaccumulation-based toxicity that could occur after short-term pulses. Regarding the USEPA's draft intermittent Se criteria, the biokinetic modeling indicates that they may be overly protective for selenate pulses but potentially underprotective for selenite pulses. Predictions of whole-body fish Se concentrations were highly dependent on whether the food chain was periphyton- or phytoplankton-based, because the latter had much greater Se uptake rate constants. Overall, biokinetic modeling provides an approach for developing acute Se criteria that are protective against bioaccumulation-based toxicity after trophic transfer, and it is also a useful tool for evaluating averaging

  5. Biokinetics of zinc oxide nanoparticles: toxicokinetics, biological fates, and protein interaction

    PubMed Central

    Choi, Soo-Jin; Choy, Jin-Ho

    2014-01-01

    Biokinetic studies of zinc oxide (ZnO) nanoparticles involve systematic and quantitative analyses of absorption, distribution, metabolism, and excretion in plasma and tissues of whole animals after exposure. A full understanding of the biokinetics provides basic information about nanoparticle entry into systemic circulation, target organs of accumulation and toxicity, and elimination time, which is important for predicting the long-term toxic potential of nanoparticles. Biokinetic behaviors can be dependent on physicochemical properties, dissolution property in biological fluids, and nanoparticle–protein interaction. Moreover, the determination of biological fates of ZnO nanoparticles in the systemic circulation and tissues is critical in interpreting biokinetic behaviors and predicting toxicity potential as well as mechanism. This review focuses on physicochemical factors affecting the biokinetics of ZnO nanoparticles, in concert with understanding bioavailable fates and their interaction with proteins. PMID:25565844

  6. Internal dose assessment of 210Po using biokinetic modeling and urinary excretion measurement

    PubMed Central

    Gerstmann, Udo; Giussani, Augusto; Oeh, Uwe; Paretzke, Herwig G.

    2007-01-01

    The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 (210Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of 210Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of 210Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 × 10−8 (1.4 × 10−7) Sv Bq−1, 2.0 × 10−7 (9.6 × 10−7) Sv Bq−1 over 10 days, 5.2 × 10−7 (2.0 × 10−6) Sv Bq−1 over 30 days and 1.0 × 10−6 (3.0 × 10−6) Sv Bq−1 over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of 210Po are 1.1 × 10−3 (1.0 × 10−4) on day 1, 2.0 × 10−3 (1.9 × 10−4) on day 10, 1.3 × 10−3 (1.7 × 10−4) on day 30 and 3.6 × 10−4 (8.3 × 10−5) Bq d−1 on day 100, respectively. The resulting committed effective doses range from 2.1 × 10−3 to 1.7 × 10−2 mSv by an assumption of ingestion and from 5.5 × 10−2 to 4.5 × 10−1 mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the

  7. Assessing the reliability of dose coefficients for exposure to radioiodine by members of the public, accounting for dosimetric and risk model uncertainties.

    PubMed

    Puncher, M; Zhang, W; Harrison, J D; Wakeford, R

    2017-06-26

    Assessments of risk to a specific population group resulting from internal exposure to a particular radionuclide can be used to assess the reliability of the appropriate International Commission on Radiological Protection (ICRP) dose coefficients used as a radiation protection device for the specified exposure pathway. An estimate of the uncertainty on the associated risk is important for informing judgments on reliability; a derived uncertainty factor, UF, is an estimate of the 95% probable geometric difference between the best risk estimate and the nominal risk and is a useful tool for making this assessment. This paper describes the application of parameter uncertainty analysis to quantify uncertainties resulting from internal exposures to radioiodine by members of the public, specifically 1, 10 and 20-year old females from the population of England and Wales. Best estimates of thyroid cancer incidence risk (lifetime attributable risk) are calculated for ingestion or inhalation of 129 I and 131 I, accounting for uncertainties in biokinetic model and cancer risk model parameter values. These estimates are compared with the equivalent ICRP derived nominal age-, sex- and population-averaged estimates of excess thyroid cancer incidence to obtain UFs. Derived UF values for ingestion or inhalation of 131 I for 1 year, 10-year and 20-year olds are around 28, 12 and 6, respectively, when compared with ICRP Publication 103 nominal values, and 9, 7 and 14, respectively, when compared with ICRP Publication 60 values. Broadly similar results were obtained for 129 I. The uncertainties on risk estimates are largely determined by uncertainties on risk model parameters rather than uncertainties on biokinetic model parameters. An examination of the sensitivity of the results to the risk models and populations used in the calculations show variations in the central estimates of risk of a factor of around 2-3. It is assumed that the direct proportionality of excess thyroid cancer

  8. Biokinetics and internal dosimetry of inhaled metal tritide particles

    NASA Astrophysics Data System (ADS)

    Wang, Yansheng

    1998-12-01

    Metal tritides (MT), stable chemical compounds of tritium, are widely used in nuclear engineering facilities. MT particles can be released as aerosols. Inhaling MT particles is a potential occupational radiation hazard. Little information is available on their dissolution behavior, biokinetics, and dosimetry. The objectives of present dissertation are to estimate dissolution rates, to develop biokinetic models, to improve internal dosimetric considerations, and to classify MT materials. This study consisted of three phases: In vitro dissolution in a simulated lung fluid, In vivo rat experiments on retention and clearance, and biokinetic modeling and dosimetric evaluation. There was a supporting study on self- absorption of tritium beta in MT particles. MT materials used in this study were titanium (Ti) and zirconium (Zr) tritides. Results shows considerable self-absorption of beta particles and their energy, even for respirable MT particles smaller than 5 μm. The self-absorption factors should be required for counting MT particle samples and for estimating absorbed dose to tissues. In vitro and in vivo dissolution data indicate that Ti and Zr tritides are poorly soluble materials. Ti tritide belongs to the W class or M type while Zr tritide can be classified as Y class or S type. Due to long retention time of the MT particles, tritium betas directly from the particles contribute over 90% of the absorbed dose to lung. The lung dose contributes most of the effective dose to the whole body. Dissolved tritium including tritiated water (HTO) and organically bound tritium (OBT) has less effect on the lung dose and effective dose. Results on the annual limit on intake (ALI) indicate that the current radiation protection guideline based on HTO is not adequate for inhalation exposure to MT particles and needs to be modified. The biokinetic models developed in this study have predictive powers to estimate the consequences of a human inhalation exposure to MT aerosols. The

  9. Strontium biokinetic model for the lactating woman and transfer to breast milk: application to Techa River studies.

    PubMed

    Shagina, N B; Tolstykh, E I; Fell, T P; Smith, T J; Harrison, J D; Degteva, M O

    2015-09-01

    This paper presents a biokinetic model for strontium metabolism in the lactating woman and transfer to breast milk for members of Techa River communities exposed as a result of discharges of liquid radioactive wastes from the Mayak plutonium production facility (Russia) in the early 1950s. This model was based on that developed for the International Commission for Radiological Protection with modifications to account for population specific features of breastfeeding and maternal bone mineral metabolism. The model is based on a biokinetic model for the adult female with allowances made for changes in mineral metabolism during periods of exclusive and partial breast-feeding. The model for females of all ages was developed earlier from extensive data on (90)Sr-body measurements for Techa Riverside residents. Measurements of (90)Sr concentrations in the maternal skeleton and breast milk obtained in the1960s during monitoring of global fallout in the Southern Urals region were used for evaluation of strontium transfer to breast and breast milk. The model was validated with independent data from studies of global fallout in Canada and measurements of (90)Sr body-burden in women living in the Techa River villages who were breastfeeding during maximum (90)Sr-dietary intakes. The model will be used in evaluations of the intake of strontium radioisotopes in breast milk by children born in Techa River villages during the radioactive releases and quantification of (90)Sr retention in the maternal skeleton.

  10. Human respiratory tract model for radiological protection: a revision of the ICRP Dosimetric Model for the Respiratory System.

    PubMed

    Bair, W J

    1989-01-01

    In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users. This should facilitate application of the revised human respiratory tract model to worldwide radiation protection needs.

  11. Laboratory-scale in situ bioremediation in heterogeneous porous media: biokinetics-limited scenario.

    PubMed

    Song, Xin; Hong, Eunyoung; Seagren, Eric A

    2014-03-01

    Subsurface heterogeneities influence interfacial mass-transfer processes and affect the application of in situ bioremediation by impacting the availability of substrates to the microorganisms. However, for difficult-to-degrade compounds, and/or cases with inhibitory biodegradation conditions, slow biokinetics may also limit the overall bioremediation rate, or be as limiting as mass-transfer processes. In this work, a quantitative framework based on a set of dimensionless coefficients was used to capture the effects of the competing interfacial and biokinetic processes and define the overall rate-limiting process. An integrated numerical modeling and experimental approach was used to evaluate application of the quantitative framework for a scenario in which slow-biokinetics limited the overall bioremediation rate of a polycyclic aromatic hydrocarbon (naphthalene). Numerical modeling was conducted to simulate the groundwater flow and naphthalene transport and verify the system parameters, which were used in the quantitative framework application. The experiments examined the movement and biodegradation of naphthalene in a saturated, heterogeneous intermediate-scale flow cell with two layers of contrasting hydraulic conductivities. These experiments were conducted in two phases: Phase I, simulating an inhibited slow biodegradation; and Phase II, simulating an engineered bioremediation, with system perturbations selected to enhance the slow biodegradation rate. In Phase II, two engineered perturbations to the system were selected to examine their ability to enhance in situ biodegradation. In the first perturbation, nitrogen and phosphorus in excess of the required stoichiometric amounts were spiked into the influent solution to mimic a common remedial action taken in the field. The results showed that this perturbation had a moderate positive impact, consistent with slow biokinetics being the overall rate-limiting process. However, the second perturbation, which was to

  12. An image-based skeletal dosimetry model for the ICRP reference adult female—internal electron sources

    NASA Astrophysics Data System (ADS)

    O'Reilly, Shannon E.; DeWeese, Lindsay S.; Maynard, Matthew R.; Rajon, Didier A.; Wayson, Michael B.; Marshall, Emily L.; Bolch, Wesley E.

    2016-12-01

    An image-based skeletal dosimetry model for internal electron sources was created for the ICRP-defined reference adult female. Many previous skeletal dosimetry models, which are still employed in commonly used internal dosimetry software, do not properly account for electron escape from trabecular spongiosa, electron cross-fire from cortical bone, and the impact of marrow cellularity on active marrow self-irradiation. Furthermore, these existing models do not employ the current ICRP definition of a 50 µm bone endosteum (or shallow marrow). Each of these limitations was addressed in the present study. Electron transport was completed to determine specific absorbed fractions to both active and shallow marrow of the skeletal regions of the University of Florida reference adult female. The skeletal macrostructure and microstructure were modeled separately. The bone macrostructure was based on the whole-body hybrid computational phantom of the UF series of reference models, while the bone microstructure was derived from microCT images of skeletal region samples taken from a 45 years-old female cadaver. The active and shallow marrow are typically adopted as surrogate tissue regions for the hematopoietic stem cells and osteoprogenitor cells, respectively. Source tissues included active marrow, inactive marrow, trabecular bone volume, trabecular bone surfaces, cortical bone volume, and cortical bone surfaces. Marrow cellularity was varied from 10 to 100 percent for active marrow self-irradiation. All other sources were run at the defined ICRP Publication 70 cellularity for each bone site. A total of 33 discrete electron energies, ranging from 1 keV to 10 MeV, were either simulated or analytically modeled. The method of combining skeletal macrostructure and microstructure absorbed fractions assessed using MCNPX electron transport was found to yield results similar to those determined with the PIRT model applied to the UF adult male skeletal dosimetry model. Calculated

  13. Development of skeletal system for mesh-type ICRP reference adult phantoms

    NASA Astrophysics Data System (ADS)

    Yeom, Yeon Soo; Wang, Zhao Jun; Tat Nguyen, Thang; Kim, Han Sung; Choi, Chansoo; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Chung, Beom Sun; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik

    2016-10-01

    The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (⩽4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to ~1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.

  14. Management of radon: a review of ICRP recommendations.

    PubMed

    Vaillant, Ludovic; Bataille, Céline

    2012-09-01

    This article proposes a review of past and current ICRP publications dealing with the management of radon exposures. Its main objective is to identify and discuss the driving factors that have been used by the Commission during the last 50 years so as to better appreciate current issues regarding radon exposure management. The analysis shows that major evolutions took place in very recent years. As far as the management of radon exposures is concerned, ICRP recommended, until ICRP Publication 103 (ICRP 2007 ICRP Publication 103; Ann. ICRP 37), to use action levels and to consider only exposures above these levels. The Commission has reviewed its approach and now proposes to manage any radon exposure through the application of the optimisation principle and associated reference levels. As far as the assessment of the radon risk is concerned, it appears that the successive changes made by ICRP did not have a strong impact on the values of radon gas concentration recommended as action levels either in dwellings or in workplaces. The major change occurred in late 2009 with the publication of the ICRP Statement on Radon, which acknowledged that the radon risk has been underestimated by a factor of 2, thus inducing a major revision of radon reference levels.

  15. Conversion of ICRP male reference phantom to polygon-surface phantom

    NASA Astrophysics Data System (ADS)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  16. Cadmium bioavailability to Hyalella azteca from a periphyton diet compared to an artificial diet and application of a biokinetic model.

    PubMed

    Golding, Lisa A; Borgmann, Uwe; George Dixon, D

    2013-01-15

    Differences between the bioavailability of cadmium in a periphyton diet and an artificial laboratory diet (TetraMin(®)) have important consequences for predicting bioaccumulation and toxicity in the freshwater amphipod Hyalella azteca. The assimilation efficiency (AE) of Cd was compared between periphyton and TetraMin(®) at low (1510 and 358 nmol/g ash-free dry mass respectively) and chronically lethal (31,200 and 2890 nmol/g ash-free dry mass respectively) Cd concentrations and in fresh and dry forms using a (109)Cd radiotracer pulse-chase feeding technique. Assimilation efficiency of Cd from periphyton (AE=3-14%) was lower than that for TetraMin(®) (AE=44-86%) regardless of Cd concentration or food form. Ingestion rate (IR) was lower for dry than fresh forms of periphyton (0.042 and 0.16 g AFDM/g H. azteca/day respectively) and TetraMin(®) (0.19 and 0.87 AFDM/g H. azteca/day respectively) and depuration rate (k(e)) did not differ statistically with food type, form or Cd concentration (0.032-0.094 d(-1)). Biokinetic models with parameters of AE, IR and k(e) were used to estimate bioaccumulation from the separate food types. These estimates were compared to those from an independent chronic Cd saturation bioaccumulation model. While the model estimates did not concur, a sensitivity analysis indicated that AE and IR were the most influential biokinetic model parameters for Cd in periphyton and TetraMin(®) respectively. It was hypothesized that AE was underestimated for Cd in periphyton due to a non-adapted gut enzyme system and IR was overestimated for Cd in TetraMin(®) due to an initial rapid ingestion phase in H. azteca's feeding habits. This research demonstrated the importance of using ecologically relevant food types in laboratory experiments and verifying acute biokinetic model predictions of dietary metal contribution with those derived from a chronic exposure which is more representative of a field exposure scenario. Crown Copyright © 2012. Published

  17. The conversion of exposures due to radon into the effective dose: the epidemiological approach.

    PubMed

    Beck, T R

    2017-11-01

    The risks and dose conversion coefficients for residential and occupational exposures due to radon were determined with applying the epidemiological risk models to ICRP representative populations. The dose conversion coefficient for residential radon was estimated with a value of 1.6 mSv year -1 per 100 Bq m -3 (3.6 mSv per WLM), which is significantly lower than the corresponding value derived from the biokinetic and dosimetric models. The dose conversion coefficient for occupational exposures with applying the risk models for miners was estimated with a value of 14 mSv per WLM, which is in good accordance with the results of the dosimetric models. To resolve the discrepancy regarding residential radon, the ICRP approaches for the determination of risks and doses were reviewed. It could be shown that ICRP overestimates the risk for lung cancer caused by residential radon. This can be attributed to a wrong population weighting of the radon-induced risks in its epidemiological approach. With the approach in this work, the average risks for lung cancer were determined, taking into account the age-specific risk contributions of all individuals in the population. As a result, a lower risk coefficient for residential radon was obtained. The results from the ICRP biokinetic and dosimetric models for both, the occupationally exposed working age population and the whole population exposed to residential radon, can be brought in better accordance with the corresponding results of the epidemiological approach, if the respective relative radiation detriments and a radiation-weighting factor for alpha particles of about ten are used.

  18. Bayesian model selection validates a biokinetic model for zirconium processing in humans

    PubMed Central

    2012-01-01

    Background In radiation protection, biokinetic models for zirconium processing are of crucial importance in dose estimation and further risk analysis for humans exposed to this radioactive substance. They provide limiting values of detrimental effects and build the basis for applications in internal dosimetry, the prediction for radioactive zirconium retention in various organs as well as retrospective dosimetry. Multi-compartmental models are the tool of choice for simulating the processing of zirconium. Although easily interpretable, determining the exact compartment structure and interaction mechanisms is generally daunting. In the context of observing the dynamics of multiple compartments, Bayesian methods provide efficient tools for model inference and selection. Results We are the first to apply a Markov chain Monte Carlo approach to compute Bayes factors for the evaluation of two competing models for zirconium processing in the human body after ingestion. Based on in vivo measurements of human plasma and urine levels we were able to show that a recently published model is superior to the standard model of the International Commission on Radiological Protection. The Bayes factors were estimated by means of the numerically stable thermodynamic integration in combination with a recently developed copula-based Metropolis-Hastings sampler. Conclusions In contrast to the standard model the novel model predicts lower accretion of zirconium in bones. This results in lower levels of noxious doses for exposed individuals. Moreover, the Bayesian approach allows for retrospective dose assessment, including credible intervals for the initially ingested zirconium, in a significantly more reliable fashion than previously possible. All methods presented here are readily applicable to many modeling tasks in systems biology. PMID:22863152

  19. The internal dosimetry code PLEIADES.

    PubMed

    Fell, T P; Phipps, A W; Smith, T J

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts-the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included.

  20. Basis for standards: ICRP activities.

    PubMed

    Vano, E

    2015-07-01

    The purpose of this chapter is to describe work achieved recently by the International Commission on Radiological Protection (ICRP) and especially by Committee 3 (Protection in Medicine) and its use for standards. In March 1960, the Board of Governors of the International Atomic Energy Agency approved the Agency's 'Health and Safety Measures', stating that the Agency's 'Basic Safety Standards' (BSS) would be based, to the extent possible, on the recommendations of the ICRP. In a similar way, the Council of the European Union took into account the new recommendations of the ICRP when adopting the new Directive 2013/59/EURATOM that laid down BSS for protection against the dangers arising from exposure to ionising radiation. The new limit for the lens of the eyes for occupational exposures has been incorporated into these international standards and several articles dealing with medical exposures: justification, optimisation, recording patient doses, the use of diagnostic reference levels, training, accidental and unintended exposures, etc. have also been included in agreement with the ICRP recommendations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Parameter uncertainty analysis of a biokinetic model of caesium

    DOE PAGES

    Li, W. B.; Klein, W.; Blanchardon, Eric; ...

    2014-04-17

    Parameter uncertainties for the biokinetic model of caesium (Cs) developed by Leggett et al. were inventoried and evaluated. The methods of parameter uncertainty analysis were used to assess the uncertainties of model predictions with the assumptions of model parameter uncertainties and distributions. Furthermore, the importance of individual model parameters was assessed by means of sensitivity analysis. The calculated uncertainties of model predictions were compared with human data of Cs measured in blood and in the whole body. It was found that propagating the derived uncertainties in model parameter values reproduced the range of bioassay data observed in human subjects atmore » different times after intake. The maximum ranges, expressed as uncertainty factors (UFs) (defined as a square root of ratio between 97.5th and 2.5th percentiles) of blood clearance, whole-body retention and urinary excretion of Cs predicted at earlier time after intake were, respectively: 1.5, 1.0 and 2.5 at the first day; 1.8, 1.1 and 2.4 at Day 10 and 1.8, 2.0 and 1.8 at Day 100; for the late times (1000 d) after intake, the UFs were increased to 43, 24 and 31, respectively. The model parameters of transfer rates between kidneys and blood, muscle and blood and the rate of transfer from kidneys to urinary bladder content are most influential to the blood clearance and to the whole-body retention of Cs. For the urinary excretion, the parameters of transfer rates from urinary bladder content to urine and from kidneys to urinary bladder content impact mostly. The implication and effect on the estimated equivalent and effective doses of the larger uncertainty of 43 in whole-body retention in the later time, say, after Day 500 will be explored in a successive work in the framework of EURADOS.« less

  2. Effect of Dietary Intake of Stable Iodine on Dose-per-unit-intake Factors for 99Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.

    It is well-known that the human thyroid concentrates iodine more than 100 times the concentration in plasma. Also well-known is the fact that large amounts of stable iodine in the diet can limit thyroid uptake of total iodine; this is the basis for administering potassium iodide following a release of radioiodine from a nuclear reactor accident or nuclear weapon detonation. Many researchers have shown enhanced concentrations of both organic and inorganic iodine in saliva and breast milk. Technetium-99 is a long-lived (231,000 year half-life) radionuclide of concern in the management of high-level radioactive waste. There is no doubt that 99Tc,more » if it is in groundwater, will be found in the chemical form of pertechnetate, 99TcO4?. Pertechnetate is a large anion, almost identical in size to iodide, I?. The nuclear medicine literature shows that pertechnetate concentrates in the thyroid, salivary glands, and lactating breast in addition to the stomach, liver, and alimentary tract as currently recognized by the International Commission on Radiological Protection (ICRP). The fact that large intakes of stable iodine (127I) in the diet limit uptake of iodine by the thyroid leads one to generalize that stable iodine in the diet may also limit thyroid uptake of pertechnetate. While there is at least one report that iodine in the diet blocks uptake of 99mTcO4? by the thyroid and salivary glands (which have the same Na/I symporter, the biochemical concentration mechanism), the level of protective effect seen for blocking radioactive iodine is not expected for 99TcO4? because pertechnetate does not become organically bound in the thyroid and thus is not retained for months the way iodide is. While it does account for Tc concentration in the thyroid, the existing ICRP biokinetic model for technetium does not take enhanced concentrations in salivary gland and breast tissue into account. From the survey of the nuclear medicine literature, it is not possible to compute the

  3. ICRP - What's happening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meinhold, C.B.

    1982-01-01

    This paper discusses the goals of the ICRP for the 1980 decade in optimizing radiation protection in the areas of workers, patients, and the public. Economic and operational concerns are expressed. (PSB)

  4. The recommendations of ICRP Publication 111 in the light of the ICRP dialogue initiative in Fukushima.

    PubMed

    Lochard, J

    2016-12-01

    Publication 111, published by the International Commission on Radiological Protection (ICRP) in 2009, provided the first recommendations for dealing with the long-term recovery phase after a nuclear accident. Its focus is on the protection of people living in long-term contaminated areas after a nuclear accident, drawing on the experience of the Belarus population, Cumbrian sheep farmers in the UK, and Sami reindeer herders in Norway affected by the fallout from Chernobyl. The ICRP dialogue initiative in Fukushima confirmed what had been identified after Chernobyl, namely the very strong concern for health, particularly that of children, loss of control over everyday life, apprehension about the future, disintegration of family life and of the social and economic fabric, and the threat to the autonomy and dignity of affected people. Through their testimonies and reflections, the participants of the 12 dialogue meetings shed light on this complex situation. The ICRP dialogue initiative also confirmed that the wellbeing of the affected people is at stake, and radiological protection must focus on rehabilitation of their living conditions. The challenge is to incorporate the important clarifications resulting from the ICRP dialogue initiative into the updated version of Publication 111 that is currently in development. This paper does not necessarily reflect the views of the International Commission on Radiological Protection.

  5. Hybrid pregnant reference phantom series based on adult female ICRP reference phantom

    NASA Astrophysics Data System (ADS)

    Rafat-Motavalli, Laleh; Miri-Hakimabad, Hashem; Hoseinian-Azghadi, Elie

    2018-03-01

    This paper presents boundary representation (BREP) models of pregnant female and her fetus at the end of each trimester. The International Commission on Radiological Protection (ICRP) female reference voxel phantom was used as a base template in development process of the pregnant hybrid phantom series. The differences in shape and location of the displaced maternal organs caused by enlarging uterus were also taken into account. The CT and MR images of fetus specimens and pregnant patients of various ages were used to replace the maternal abdominal pelvic organs of template phantom and insert the fetus inside the gravid uterus. Each fetal model contains 21 different organs and tissues. The skeletal model of the fetus also includes age-dependent cartilaginous and ossified skeletal components. The replaced maternal organ models were converted to NURBS surfaces and then modified to conform to reference values of ICRP Publication 89. The particular feature of current series compared to the previously developed pregnant phantoms is being constructed upon the basis of ICRP reference phantom. The maternal replaced organ models are NURBS surfaces. With this great potential, they might have the feasibility of being converted to high quality polygon mesh phantoms.

  6. Calculation of local skin doses with ICRP adult mesh-type reference computational phantoms

    NASA Astrophysics Data System (ADS)

    Yeom, Yeon Soo; Han, Haegin; Choi, Chansoo; Nguyen, Thang Tat; Lee, Hanjin; Shin, Bangho; Kim, Chan Hyeong; Han, Min Cheol

    2018-01-01

    Recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) developed new mesh-type reference computational phantoms (MRCPs) for adult males and females in order to address the limitations of the current voxel-type reference phantoms described in ICRP Publication 110 due to their limited voxel resolutions and the nature of the voxel geometry. One of the substantial advantages of the MRCPs over the ICRP-110 reference phantoms is the inclusion of a 50-μm-thick radiosensitive skin basal-cell layer; however, a methodology for calculating the local skin dose (LSD), i.e., the maximum dose to the basal layer averaged over a 1-cm2 area, has yet to be developed. In the present study, a dedicated program for the LSD calculation with the MRCPs was developed based on the mean shift algorithm and the Geant4 Monte Carlo code. The developed program was used to calculate local skin dose coefficients (LSDCs) for electrons and alpha particles, which were then compared with the values given in ICRP Publication 116 that were produced with a simple tissue-equivalent cube model. The results of the present study show that the LSDCs of the MRCPs are generally in good agreement with the ICRP-116 values for alpha particles, but for electrons, significant differences are found at energies higher than 0.15 MeV. The LSDCs of the MRCPs are greater than the ICRP-116 values by as much as 2.7 times at 10 MeV, which is due mainly to the different curvature between realistic MRCPs ( i.e., curved) and the simple cube model ( i.e., flat).

  7. Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms

    NASA Astrophysics Data System (ADS)

    Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun

    2017-03-01

    It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.

  8. Ethos in Fukushima and the ICRP dialogue seminars.

    PubMed

    Ando, R

    2016-12-01

    Ethos in Fukushima, a non-profit organisation, participated in 10 of the 12 International Commission on Radiological Protection (ICRP) dialogue seminars over the past 4 years. The slides and videos that were shown at the seminars are recorded on the Ethos in Fukushima website ( http://ethos-fukushima.blogspot.jp/p/icrp-dialogue.html ). I would like to introduce the activities of Ethos in Fukushima to date, and explain why the ICRP dialogue materials have come to be published on its website.

  9. Is ICRP guidance on the use of reference levels consistent?

    PubMed

    Hedemann-Jensen, Per; McEwan, Andrew C

    2011-12-01

    In ICRP 103, which has replaced ICRP 60, it is stated that no fundamental changes have been introduced compared with ICRP 60. This is true except that the application of reference levels in emergency and existing exposure situations seems to be applied inconsistently, and also in the related publications ICRP 109 and ICRP 111. ICRP 103 emphasises that focus should be on the residual doses after the implementation of protection strategies in emergency and existing exposure situations. If possible, the result of an optimised protection strategy should bring the residual dose below the reference level. Thus the reference level represents the maximum acceptable residual dose after an optimised protection strategy has been implemented. It is not an 'off-the-shelf item' that can be set free of the prevailing situation. It should be determined as part of the process of optimising the protection strategy. If not, protection would be sub-optimised. However, in ICRP 103 some inconsistent concepts have been introduced, e.g. in paragraph 279 which states: 'All exposures above or below the reference level should be subject to optimisation of protection, and particular attention should be given to exposures above the reference level'. If, in fact, all exposures above and below reference levels are subject to the process of optimisation, reference levels appear superfluous. It could be considered that if optimisation of protection below a fixed reference level is necessary, then the reference level has been set too high at the outset. Up until the last phase of the preparation of ICRP 103 the concept of a dose constraint was recommended to constrain the optimisation of protection in all types of exposure situations. In the final phase, the term 'dose constraint' was changed to 'reference level' for emergency and existing exposure situations. However, it seems as if in ICRP 103 it was not fully recognised that dose constraints and reference levels are conceptually different. The

  10. Assessing risk with increasingly stringent public health goals: the case of water lead and blood lead in children.

    PubMed

    Triantafyllidou, Simoni; Gallagher, Daniel; Edwards, Marc

    2014-03-01

    Previous predictions of children's blood lead levels (BLLs) through biokinetic models conclude that lead in tap water is not a primary health risk for a typical child under scenarios representative of chronic exposure, when applying a 10 μg/dL BLL of concern. Use of the US Environmental Protection Agency Integrated Exposure Uptake Biokinetic (IEUBK) model and of the International Commission on Radiological Protection (ICRP) biokinetic model to simulate children's exposure to water lead at home and at school was re-examined by expanding the scope of previous modeling efforts to consider new public health goals and improved methodology. Specifically, explicit consideration of the more sensitive population groups (e.g., young children and, particularly, formula-fed infants), the variability in BLLs amongst exposed individuals within those groups (e.g., more sensitive children at the upper tail of the BLL distribution), more conservative BLL reference values (e.g., 5 and 2 μg/dL versus 10 μg/dL) and concerns of acute exposure revealed situations where relatively low water lead levels were predicted to pose a human health concern.

  11. Quantitative biokinetics of titanium dioxide nanoparticles after oral application in rats: Part 2.

    PubMed

    Kreyling, Wolfgang G; Holzwarth, Uwe; Schleh, Carsten; Kozempel, Ján; Wenk, Alexander; Haberl, Nadine; Hirn, Stephanie; Schäffler, Martin; Lipka, Jens; Semmler-Behnke, Manuela; Gibson, Neil

    2017-05-01

    The biokinetics of a size-selected fraction (70 nm median size) of commercially available and 48 V-radiolabeled [ 48 V]TiO 2 nanoparticles has been investigated in female Wistar-Kyoto rats at retention timepoints 1 h, 4 h, 24 h and 7 days after oral application of a single dose of an aqueous [ 48 V]TiO 2 -nanoparticle suspension by intra-esophageal instillation. A completely balanced quantitative body clearance and biokinetics in all organs and tissues was obtained by applying typical [ 48 V]TiO 2 -nanoparticle doses in the range of 30-80 μg•kg -1 bodyweight, making use of the high sensitivity of the radiotracer technique. The [ 48 V]TiO 2 -nanoparticle content was corrected for nanoparticles in the residual blood retained in organs and tissue after exsanguination and for 48 V-ions not bound to TiO 2 -nanoparticles. Beyond predominant fecal excretion about 0.6% of the administered dose passed the gastro-intestinal-barrier after one hour and about 0.05% were still distributed in the body after 7 days, with quantifiable [ 48 V]TiO 2 -nanoparticle organ concentrations present in liver (0.09 ng•g -1 ), lungs (0.10 ng•g -1 ), kidneys (0.29 ng•g -1 ), brain (0.36 ng•g -1 ), spleen (0.45 ng•g -1 ), uterus (0.55 ng•g -1 ) and skeleton (0.98 ng•g -1 ). Since chronic, oral uptake of TiO 2 particles (including a nano-fraction) by consumers has continuously increased in the past decades, the possibility of chronic accumulation of such biopersistent nanoparticles in secondary organs and the skeleton raises questions about the responsiveness of their defense capacities, and whether these could be leading to adverse health effects in the population at large. After normalizing the fractions of retained [ 48 V]TiO 2 -nanoparticles to the fraction that passed the gastro-intestinal-barrier and reached systemic circulation, the biokinetics was compared to the biokinetics determined after IV-injection (Part 1). Since the biokinetics patterns

  12. Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model

    NASA Astrophysics Data System (ADS)

    Villoing, Daphnée; Marcatili, Sara; Garcia, Marie-Paule; Bardiès, Manuel

    2017-03-01

    The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model proposed by the International Commission on Radiological Protection in ICRP report 110. Monoenergetic photons and electrons (from 50 keV to 2 MeV) and four isotopes currently used in nuclear medicine (fluorine-18, lutetium-177, iodine-131 and yttrium-90) were investigated. Absorbed fractions, specific absorbed fractions and S-values were generated with GATE and MCNPX for 12 regions of interest in the ICRP 110 female computational model, thereby leading to 144 source/target pair configurations. Relative differences between GATE and MCNPX obtained in specific configurations (self-irradiation or cross-irradiation) are presented. Relative differences in absorbed fractions, specific absorbed fractions or S-values are below 10%, and in most cases less than 5%. Dosimetric results generated with GATE for the 12 volumes of interest are available as supplemental data. GATE can be safely used for radiopharmaceutical dosimetry at the clinical scale. This makes GATE a viable option for Monte Carlo modelling of both imaging and absorbed dose in nuclear medicine.

  13. Use of the ICRP system for the protection of marine ecosystems.

    PubMed

    Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Biokinetics of radiolabeled Iodophenylpentadecanoic acid (I-123-IPPA) and thallium-201 in a rabbit model of chronic myocardial infarction measured using a series of thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Medich, David Christopher

    1997-09-01

    The biokinetics of Iodophenylpentadecanoic acid (123I-IPPA) during a chronic period of myocardial infarction were determined and compared to 201Tl. IPPA was assessed as a perfusion and metabolic tracer in the scintigraphic diagnosis of coronary artery disease. The myocardial clearance kinetics were measured by placing a series of thermoluminescent dosimeters (TLDs) on normal and infarcted tissue to measure the local myocardial activity content over time. The arterial blood pool activity was fit to a bi-exponential function for 201Tl and a tri-exponential function for 123I-IPPA to estimate the left ventricle contribution to TLD response. At equilibrium, the blood pool contribution was estimated experimentally to be less than 5% of the total TLD response. The method was unable to resolve the initial uptake of the imaging agent due in part to the 2 minute TLD response integration time and in part to the 30 second lag time for the first TLD placement. A noticeable disparity was observed between the tracer concentrations of IPPA in normal and ischemic tissue of approximately 2:1. The fitting parameters (representing the biokinetic eigenvalue rate constants) were related to the fundamental rate constants of a recycling biokinetic model. The myocardial IPPA content within normal tissue was elevated after approximately 130 minutes post injection. This phenomenon was observed in all but one (950215) of the IPPA TLD kinetics curves.

  15. The mandate and work of ICRP Committee 3 on radiological protection in medicine.

    PubMed

    Miller, D L; Martin, C J; Rehani, M M

    2018-01-01

    The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.

  16. Dose conversion factors for radon: recent developments.

    PubMed

    Marsh, James W; Harrison, John D; Laurier, Dominique; Blanchardon, Eric; Paquet, François; Tirmarche, Margot

    2010-10-01

    Epidemiological studies of the occupational exposure of miners and domestic exposures of the public have provided strong and complementary evidence of the risks of lung cancer following inhalation of radon progeny. Recent miner epidemiological studies, which include low levels of exposure, long duration of follow-up, and good quality of individual exposure data, suggest higher risks of lung cancer per unit exposure than assumed previously by the International Commission on Radiological Protection (ICRP). Although risks can be managed by controlling exposures, dose estimates are required for the control of occupational exposures and are also useful for comparing sources of public exposure. Currently, ICRP calculates doses from radon and its progeny using dose conversion factors from exposure (WLM) to dose (mSv) based on miner epidemiological studies, referred to as the epidemiological approach. Revision of these dose conversion factors using risk estimates based on the most recent epidemiological data gives values that are in good agreement with the results of calculations using ICRP biokinetic and dosimetric models, the dosimetric approach. ICRP now proposes to treat radon progeny in the same way as other radionuclides and to publish dose coefficients calculated using models, for use within the ICRP system of protection.

  17. Biokinetics of nuclear fuel compounds and biological effects of nonuniform radiation.

    PubMed Central

    Lang, S; Servomaa, K; Kosma, V M; Rytömaa, T

    1995-01-01

    Environmental releases of insoluble nuclear fuel compounds may occur at nuclear power plants during normal operation, after nuclear power plant accidents, and as a consequence of nuclear weapons testing. For example, the Chernobyl fallout contained extensive amounts of pulverized nuclear fuel composed of uranium and its nonvolatile fission products. The effects of these highly radioactive particles, also called hot particles, on humans are not well known due to lack of reliable data on the extent of the exposure. However, the biokinetics and biological effects of nuclear fuel compounds have been investigated in a number of experimental studies using various cellular systems and laboratory animals. In this article, we review the biokinetic properties and effects of insoluble nuclear fuel compounds, with special reference to UO2, PuO2, and nonvolatile, long-lived beta-emitters Zr, Nb, Ru, and Ce. First, the data on hot particles, including sources, dosimetry, and human exposure are discussed. Second, the biokinetics of insoluble nuclear fuel compounds in the gastrointestinal tract and respiratory tract are reviewed. Finally, short- and long-term biological effects of nonuniform alpha- and beta-irradiation on the gastrointestinal tract, lungs, and skin are discussed. Images p920-a Figure 1. PMID:8529589

  18. Quantitative biokinetics of titanium dioxide nanoparticles after intravenous injection in rats: Part 1.

    PubMed

    Kreyling, Wolfgang G; Holzwarth, Uwe; Haberl, Nadine; Kozempel, Ján; Hirn, Stephanie; Wenk, Alexander; Schleh, Carsten; Schäffler, Martin; Lipka, Jens; Semmler-Behnke, Manuela; Gibson, Neil

    2017-05-01

    Submicrometer TiO 2 particles, including nanoparticulate fractions, are used in an increasing variety of consumer products, as food additives and also drug delivery applications are envisaged. Beyond exposure of occupational groups, this entails an exposure risk to the public. However, nanoparticle translocation from the organ of intake and potential accumulation in secondary organs are poorly understood and in many investigations excessive doses are applied. The present study investigates the biokinetics and clearance of a low single dose (typically 40-400 μg/kg BW) of 48 V-radiolabeled, pure TiO 2 anatase nanoparticles ([ 48 V]TiO 2 NP) with a median aggregate/agglomerate size of 70 nm in aqueous suspension after intravenous (IV) injection into female Wistar rats. Biokinetics and clearance were followed from one-hour to 4-weeks. The use of radiolabeled nanoparticles allowed a quantitative [ 48 V]TiO 2 NP balancing of all organs, tissues, carcass and excretions of each rat without having to account for chemical background levels possibly caused by dietary or environmental titanium exposure. Highest [ 48 V]TiO 2 NP accumulations were found in liver (95.5%ID after one day), followed by spleen (2.5%), carcass (1%), skeleton (0.7%) and blood (0.4%). Detectable nanoparticle levels were found in all other organs. The [ 48 V]TiO 2 NP content in blood decreased rapidly after 24 h while the distribution in other organs and tissues remained rather constant until day-28. The present biokinetics study is part 1 of a series of studies comparing biokinetics after three classical routes of intake (IV injection (part 1), ingestion (part 2), intratracheal instillation (part 3)) under identical laboratory conditions, in order to test the common hypothesis that IV-injection is a suitable predictor for the biokinetics fate of nanoparticles administered by different routes. This hypothesis is disproved by this series of studies.

  19. Biokinetics and bacterial communities of propionate oxidizing bacteria in phased anaerobic sludge digestion systems.

    PubMed

    Zamanzadeh, Mirzaman; Parker, Wayne J; Verastegui, Yris; Neufeld, Josh D

    2013-03-15

    Phased anaerobic digestion is a promising technology and may be a potential source of bio-energy production. Anaerobic digesters are widely used for sewage sludge stabilization and thus a better understanding of the microbial process and kinetics may allow increased volatile solids reduction and methane production through robust process operation. In this study, we analyzed the impact of phase separation and operational conditions on the bio-kinetic characteristics and communities of bacteria associated with four phased anaerobic digestion systems. In addition to significant differences between bacterial communities associated with different digester operating temperatures, our results also revealed that bacterial communities in the phased anaerobic digestion systems differed between the 1st and 2nd phase digesters and we identified strong community composition correlations with several measured physicochemical parameters. The maximum specific growth rates of propionate oxidizing bacteria (POB) in the mesophilic and thermophilic 1st phases were 11 and 23.7 mgCOD mgCOD(-1) d(-1), respectively, while those of the mesophilic and thermophilic 2nd-phase digesters were 6.7 and 18.6 mgCOD mgCOD(-1) d(-1), respectively. Hence, the biokinetic characteristics of the POB population were dependent on the digester loading. In addition, we observed that the temperature dependency factor (θ) values were higher for the less heavily loaded digesters as compared to the values obtained for the 1st-phase digesters. Our results suggested the appropriate application of two sets of POB bio-kinetic that reflect the differing growth responses as a function of propionate concentration (and/or organic loading rates). Also, modeling acetogenesis in phased anaerobic sludge digestion systems will be improved considering a population shift in separate phases. On the basis of the bio-kinetic values estimated in various digesters, high levels of propionate in the thermophilic digesters may be

  20. Radiological Protection in Space: Indication from the ICRP Task Group

    NASA Astrophysics Data System (ADS)

    Dietze, Günther

    In 2007 the International Commission on Radiological Protection (ICRP) has established a Task Group (Radiation Protection in Space) dealing with the problems of radiation protection of astronauts in space missions. Its first task is a report on "Assessment of Radiation Exposure of Astronauts in Space". When the ICRP published its general recommendations for radiological protection in 2007 (ICRP Publication 103 following ICRP Publication 60 (1991)) it was obvious that these recommendations do not really consider the special situation of astronauts in space. The radiation field with its high content of charged particles of very high energies strongly differs from usual radiation fields on ground. For example, this has consequences for the assessment of doses in the body of astronauts. The ICRP Task Group has discussed this situation and the presentation will deal with some consequences for the concept of radiation dosimetry and radiological protection in space. This includes e. g. the assessment of organ doses and the application of the effective dose concept with its definition of radiation weighting factors. Radiation quality of high energy heavy ions may be defined different than usually performed on ground. An approach of using the quality factor concept in the definition of an "effective dose" is favored for application in space missions similar to the method proposed in NCRP Report 142. New data calculated on the basis of the reference anthropomorphic voxel phantoms recommended by ICRP support this procedure. Individual dosimetry is a further subject of discussion in the Task Group. While the operational dose equivalent quantities generally in use in radiation protection on ground are not helpful for applications in space, different procedures of the assessment of organ and effective doses are applied. The Task Group is dealing with this situation.

  1. Quantitative analysis of multiple biokinetic models using a dynamic water phantom: A feasibility study

    PubMed Central

    Chiang, Fu-Tsai; Li, Pei-Jung; Chung, Shih-Ping; Pan, Lung-Fa; Pan, Lung-Kwang

    2016-01-01

    ABSTRACT This study analyzed multiple biokinetic models using a dynamic water phantom. The phantom was custom-made with acrylic materials to model metabolic mechanisms in the human body. It had 4 spherical chambers of different sizes, connected by 8 ditches to form a complex and adjustable water loop. One infusion and drain pole connected the chambers to an auxiliary silicon-based hose, respectively. The radio-active compound solution (TC-99m-MDP labeled) formed a sealed and static water loop inside the phantom. As clean feed water was infused to replace the original solution, the system mimicked metabolic mechanisms for data acquisition. Five cases with different water loop settings were tested and analyzed, with case settings changed by controlling valve poles located in the ditches. The phantom could also be changed from model A to model B by transferring its vertical configuration. The phantom was surveyed with a clinical gamma camera to determine the time-dependent intensity of every chamber. The recorded counts per pixel in each chamber were analyzed and normalized to compare with theoretical estimations from the MATLAB program. Every preset case was represented by uniquely defined, time-dependent, simultaneous differential equations, and a corresponding MATLAB program optimized the solutions by comparing theoretical calculations and practical measurements. A dimensionless agreement (AT) index was recommended to evaluate the comparison in each case. ATs varied from 5.6 to 48.7 over the 5 cases, indicating that this work presented an acceptable feasibility study. PMID:27286096

  2. Transuranic biokinetic parameters for marine invertebrates--a review.

    PubMed

    Ryan, T P

    2002-04-01

    A catalogue of biokinetic parameters for the transuranic elements plutonium, americium, curium, neptunium, and californium in marine invertebrates is presented. The parameters considered are: the seawater-animal concentration factor (CF); the sediment-animal concentration ratio (CR); transuranic assimilation efficiency; transuranic tissue distribution and transuranic elimination rates. With respect to the seawater-animal CF, authors differ considerably on how they define this parameter and a seven-point reporting system is suggested. Transuranic uptake from sediment by animals is characterised by low CRs. The assimilation efficiencies of transuranic elements in marine invertebrates are high compared to vertebrates and mammals in general and the distribution of transuranics within the body tissue of an animal is dependent on the uptake path. The elimination of transuranics from most species examined conformed to a standard biphasic exponential model though some examples with three elimination phases were identified.

  3. Biokinetics and dosimetric studies about 99mTc(V)-DMSA distribution.

    PubMed

    Correia, M B L; Magnata, S S L P; Silva, I M S; Catanho, M T J A; Lima, F F

    2010-05-10

    Research for radiodiagnostic agents should considerate biological critical parameters which will give own contribution on the absorbed dose. The dimercaptosuccinic acid (DMSA) labeled with (99m)Tc(V) is a radiopharmaceutical which has well established role in medullar thyroid carcinoma and has been proposed in evaluation of bone metastasis. This work studied the biokinetics and dosimetry of (99m)Tc(V)-DMSA by animal model. The (99m)Tc(V)-DMSA was prepared from a (III)DMSA kit alkalized. Mice (n=5) received (99m)Tc(V)DMSA i.v., they were sacrificed (30 min, 1h, 5h and 12h), the organs excised and the activities measured by a gamma counter. The results were evaluated based on %activity/g and the absorbed dose was estimated (MIRDOSE 3.0 program) by extrapolation of data from animal to human scale. The results showed the majority of organs reached the top uptake at 30 min, the greatest kidney uptake was (4.81 +/- 1.38)% activity/g, while the bone presented its highest uptake at 1h (5.49+/- 0.47)% activity/g, after 1h all the organs had activity exponential decrease. The biokinetic profile of (99m)Tc(V)-DMSA was well established, allowing quantifying of residence time, and the radiation dose estimates were made for this agent. About the absorbed dose, the preliminary results showed higher value to bone, being the soft tissue dose relatively low.

  4. The role of the ICRP in radiation protection--a view from industry.

    PubMed

    Henrichs, K

    2003-01-01

    It is the objective of this paper to discuss some aspects concerning the role and importance of the ICRP. Here, this is done with a background of practical radiation protection in industry. The author organises and controls radiation protection for a worldwide operating company, for which efficiently realised radiation safety is as relevant for its workplaces as for its products and services. According to the author's subjective observation, the ICRP has a decreasing importance in operational radiation protection. However, there are growing demands on the ICRP as it is the only basis for internationally compatible regulations and standards. It is the merit of the ICRP that an international comparison of legal protection systems and concepts should give a much more homogeneous picture than that for any other safety and protection issue. The most valuable asset of the ICRP is its credibility as a scientific authority solely committed to the effective protection of people. But its success also brings with it an obligation: there is an increasing need for more effective communication to non-experts. This and other expectations for the future are briefly discussed.

  5. Uranium levels in the diet of São Paulo City residents.

    PubMed

    Garcia, F; Barioni, A; Arruda-Neto, J D T; Deppman, A; Milian, F; Mesa, J; Rodriguez, O

    2006-07-01

    Natural levels of uranium in the diet of São Paulo City residents were studied, and radionuclide concentrations were measured by the fission track method on samples of typical adult food items. This information was used to evaluate the daily intake of uranium in individuals living in São Paulo City which is, according to our findings, around 0.97 microg U/day. Using the ICRP Uranium-model, we estimated the uranium accumulation and committed doses in some tissues and organs, as function of time. We compared the output of the ICRP uranium biokinetic model, tailored for the conditions prevailing in São Paulo, with experimental data from other localities. Such comparison was possible by means of a simple method we developed, which allows normalization among experimental results from different regions where distinct values of chronic daily intake are observed.

  6. A biokinetic model to describe consequences of inhibition/stimulation in DNA-proofreading and repair-1. Development of the model.

    PubMed

    Haschke, H

    2001-10-21

    A biokinetic model is described which deals with the mathematical consequences of the inhibition or stimulation of DNA proofreading. It demonstrates the development of the number of DNA mismatch-dependent cells (e.g. cells with a malignant phenotype), where such mismatches arise by the in situ interaction of various substances with nucleotides of the DNA. The model can test for consequences by a logic gating on an "if-then" type of analysis in relation to the separate and consecutive processes of proofreading and repair. In particular, the consequences are considered in cases where either (i) the efficacy of proofreading and repair are reduced/prevented (inhibited) or (ii) are increased by some form of stimulation. On the chosen kinetic parameters, the model is accessible to manipulation as new data arising from further investigations become available and are introduced. The model is based on recently published data which show that an increased "mutant fraction" (see note on terms) arises in DNA replication when intracellular nucleotide pools show "asymmetries" (see note on terms). Extraordinarily high mutant fractions can be predicted/have been recorded in the presence of proofreading inhibitors. The model expresses data in mathematical terms of the competition between the development of mismatch-dependent cells and those with authentic genetic information. (Feedback and metastasis-effects and those of wild-type replicates are included.) A computerized (numerical) integration of the corresponding set of differential equations is offered. (A diskette with the program CANCER.xls is available upon request.) Copyright 2001 Academic Press

  7. Impact of the new nuclear decay data of ICRP publication 107 on inhalation dose coefficients for workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manabe, K.; Endo, Akira; Eckerman, Keith F

    2010-03-01

    The impact a revision of nuclear decay data had on dose coefficients was studied using data newly published in ICRP Publication 107 (ICRP 107) and existing data from ICRP Publication 38 (ICRP 38). Committed effective dose coefficients for occupational inhalation of radionuclides were calculated using two sets of decay data with the dose and risk calculation software DCAL for 90 elements, 774 nuclides and 1572 cases. The dose coefficients based on ICRP 107 increased by over 10 % compared with those based on ICRP 38 in 98 cases, and decreased by over 10 % in 54 cases. It was foundmore » that the differences in dose coefficients mainly originated from changes in the radiation energy emitted per nuclear transformation. In addition, revisions of the half-lives, radiation types and decay modes also resulted in changes in the dose coefficients.« less

  8. Mechanism of cisplatin proximal tubule toxicity revealed by integrating transcriptomics, proteomics, metabolomics and biokinetics.

    PubMed

    Wilmes, Anja; Bielow, Chris; Ranninger, Christina; Bellwon, Patricia; Aschauer, Lydia; Limonciel, Alice; Chassaigne, Hubert; Kristl, Theresa; Aiche, Stephan; Huber, Christian G; Guillou, Claude; Hewitt, Philipp; Leonard, Martin O; Dekant, Wolfgang; Bois, Frederic; Jennings, Paul

    2015-12-25

    Cisplatin is one of the most widely used chemotherapeutic agents for the treatment of solid tumours. The major dose-limiting factor is nephrotoxicity, in particular in the proximal tubule. Here, we use an integrated omics approach, including transcriptomics, proteomics and metabolomics coupled to biokinetics to identify cell stress response pathways induced by cisplatin. The human renal proximal tubular cell line RPTEC/TERT1 was treated with sub-cytotoxic concentrations of cisplatin (0.5 and 2 μM) in a daily repeat dose treating regime for up to 14 days. Biokinetic analysis showed that cisplatin was taken up from the basolateral compartment, transported to the apical compartment, and accumulated in cells over time. This is in line with basolateral uptake of cisplatin via organic cation transporter 2 and bioactivation via gamma-glutamyl transpeptidase located on the apical side of proximal tubular cells. Cisplatin affected several pathways including, p53 signalling, Nrf2 mediated oxidative stress response, mitochondrial processes, mTOR and AMPK signalling. In addition, we identified novel pathways changed by cisplatin, including eIF2 signalling, actin nucleation via the ARP/WASP complex and regulation of cell polarization. In conclusion, using an integrated omic approach together with biokinetics we have identified both novel and established mechanisms of cisplatin toxicity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Biokinetics and dosimetry with 177Lu-DOTA-TATE in athymic mice with induced pancreatic malignant tumours

    NASA Astrophysics Data System (ADS)

    Rodríguez-Cortés, J.; de Murphy, C. Arteaga; Ferro-Flores, Ge; Pedraza-López, M.; Murphy-Stack, E.

    Malignant pancreatic tumours induced in athymic mice are a good model for peptide receptor targeted radiotherapy. The objective of this research was to determine biokinetic parameters in mice, in order to estimate the induced pancreatic tumour absorbed doses and to evaluate an `in house' 177Lu-DOTA-TATE radiopharmaceutical as part of preclinical studies for targeted therapy in humans. AR42J murine pancreas cancer cells expressing somatostatin receptors, were implanted in athymic mice (nD22) to obtain biokinetic and dosimetric data of 177Lu-DOTA-TATE. The mean tumour uptake 2 h post injection was 14.76±1.9% I.A./g; kidney and pancreas uptake, at the same time, were 7.27±1.1% I.A./g (1.71±0.90%/organ) and 4.20±0.98% I.A./g (0.42±0.03%/organ), respectively. The mean absorbed dose to tumour, kidney and pancreas was 0.58±0.02 Gy/MBq; 0.23±0.01 Gy/MBq and 0.14±0.01 Gy/MBq, respectively. These studies justify further dosimetric estimations to ensure that 177Lu-DOTA-TATE will act as expected in humans.

  10. An image-based skeletal dosimetry model for the ICRP reference adult male—internal electron sources

    NASA Astrophysics Data System (ADS)

    Hough, Matthew; Johnson, Perry; Rajon, Didier; Jokisch, Derek; Lee, Choonsik; Bolch, Wesley

    2011-04-01

    In this study, a comprehensive electron dosimetry model of the adult male skeletal tissues is presented. The model is constructed using the University of Florida adult male hybrid phantom of Lee et al (2010 Phys. Med. Biol. 55 339-63) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow, associated with radiogenic leukemia, and total shallow marrow, associated with radiogenic bone cancer. Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following sources: bone marrow (active and inactive), trabecular bone (surfaces and volumes), and cortical bone (surfaces and volumes). Specific absorbed fractions are computed according to the MIRD schema, and are given as skeletal-averaged values in the paper with site-specific values reported in both tabular and graphical format in an electronic annex available from http://stacks.iop.org/0031-9155/56/2309/mmedia. The distribution of cortical bone and spongiosa at the macroscopic dimensions of the phantom, as well as the distribution of trabecular bone and marrow tissues at the microscopic dimensions of the phantom, is imposed through detailed analyses of whole-body ex vivo CT images (1 mm resolution) and spongiosa-specific ex vivo microCT images (30 µm resolution), respectively, taken from a 40 year male cadaver. The method utilized in this work includes: (1) explicit accounting for changes in marrow self-dose with variations in marrow cellularity, (2) explicit accounting for electron escape from spongiosa, (3) explicit consideration of spongiosa cross-fire from cortical bone, and (4) explicit consideration of the ICRP's change in the surrogate tissue region defining the location of the osteoprogenitor cells (from a 10 µm endosteal layer covering the trabecular and cortical surfaces to a 50 µm shallow marrow layer covering trabecular and medullary cavity surfaces). Skeletal

  11. Inorganic cobalt supplementation: prediction of cobalt levels in whole blood and urine using a biokinetic model.

    PubMed

    Unice, Kenneth M; Monnot, Andrew D; Gaffney, Shannon H; Tvermoes, Brooke E; Thuett, Kerry A; Paustenbach, Dennis J; Finley, Brent L

    2012-07-01

    Soluble cobalt (Co) supplements with recommended daily doses up to 1000 μg Co/day are increasingly being marketed to consumers interested in healthy living practices. For example, some athletes may consider using Co supplements as blood doping agents, as Co is known to stimulate erythropoesis. However, the distribution and excretion kinetics of ingested Co are understood in a limited fashion. We used a Co-specific biokinetic model to estimate whole blood and urine Co levels resulting from oral exposure or ingestion of Co in amounts exceeding typical dietary intake rates. Following 10 days of Co supplementation at a rate of 400 to 1000 μg/day, predicted adult Co concentrations range from 1.7 to 10 μg/L in whole blood, and from 20 to 120 μg/L in urine. Chronic supplementation (≥ 1 year) at a rate of 1000 μg Co/day is predicted to result in blood levels of 5.7 to 13 μg/L, and in urine levels from 65 to 150 μg/L. The model predictions are within those measured in humans following ingestion of known doses. The methodology presented in this paper can be used to predict urinary or blood Co levels following acute or chronic occupational incidental ingestion, medicinal therapy, supplemental intake, or other non-occupational exposures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Annual limits on intake (ALI) values in ICRP 61 and 10 CFR Part 20 (1991)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, M.; Kearfott, K.J.

    The newest major revision of Nuclear Regulatory Commission`s 10 CFR Part 20 (1991) incorporates the new dose methodology system, revised limits, and improved internal dose computations presented in International Commission on Radiation Protection (ICRP) Publication 30 (1979). A year before the issue of this revised 10 CFR Part 20, the ICRP dispatched Publication 61 (1990). This new ICRP report employed different dose limits, in addition to incorporating more recent biological information and variations in physiological and different tissue weighing factors for various organs. An investigation of the numerical differences in the Annual Limit on Intake (ALI) reported in this moremore » recent international regulations and those of the new regulations was thus undertaken. Overall means, medians, modes, maximum, minimum, and ranges of the percent changes are almost identical for ingestion and inhalation, although the percent difference between 10 CFR and ICRP Publication 61 showed minor differences for individual radionuclides. Approximately 334 of 1,351 radionuclides for inhalation and 173 of 771 radionuclides for ingestion have much less restrictive ALIs in the new ICRP recommendations than in the old, with some of those limits increased by at least a factor of two. Approximately 51% of the radionuclides for ingestion intake and 48% of radionuclides for inhalation intake showed changes of greater than 25%. The radionuclides observed to have much less restrictive ALIs are primarily the radionuclides of thorium, mercury, plutonium, uranium, and americium which have short effective clearance rates. While many countries have already applied the ICRP 61 recommendations to their radiation protection standards, using the ICRP 30 recommendation in the United States does not match the international standards even when the values of the ALIs are adjusted for differences in dose limits.« less

  13. New Radiation Dosimetry Estimates for [18F]FLT based on Voxelized Phantoms.

    PubMed

    Mendes, B M; Ferreira, A V; Nascimento, L T C; Ferreira, S M Z M D; Silveira, M B; Silva, J B

    2018-04-25

    3'-Deoxy-3-[ 18 F]fluorothymidine, or [ 18 F]FLT, is a positron emission tomography (PET) tracer used in clinical studies for noninvasive assessment of proliferation activity in several types of cancer. Although the use of this PET tracer is expanding, to date, few studies concerning its dosimetry have been published. In this work, new [ 18 F]FLT dosimetry estimates are determined for human and mice using Monte Carlo simulations. Modern voxelized male and female phantoms and [ 18 F]FLT biokinetic data, both published by the ICRP, were used for simulations of human cases. For most human organs/tissues the absorbed doses were higher than those reported in ICRP Publication 128. An effective dose of 1.70E-02 mSv/MBq to the whole body was determined, which is 13.5% higher than the ICRP reference value. These new human dosimetry estimates obtained using more realistic human phantoms represent an advance in the knowledge of [ 18 F]FLT dosimetry. In addition, mice biokinetic data were obtained experimentally. These data and a previously developed voxelized mouse phantom were used for simulations of animal cases. Concerning animal dosimetry, absorbed doses for organs/tissues ranged from 4.47 ± 0.75 to 155.74 ± 59.36 mGy/MBq. The obtained set of organ/tissue radiation doses for healthy Swiss mice is a useful tool for application in animal experiment design.

  14. Consideration of the ICRP 2006 revised tissue weighting factors on age-dependent values of the effective dose for external photons

    NASA Astrophysics Data System (ADS)

    Lee, Choonsik; Lee, Choonik; Han, Eun Young; Bolch, Wesley E.

    2007-01-01

    The effective dose recommended by the International Commission on Radiological Protection (ICRP) is the sum of organ equivalent doses weighted by corresponding tissue weighting factors, wT. ICRP is in the process of revising its 1990 recommendations on the effective dose where new values of organs and tissue weighting factors have been proposed and published in draft form for consultation by the radiological protection community. In its 5 June 2006 draft recommendations, new organs and tissues have been introduced in the effective dose which do not exist within the 1987 Oak Ridge National Laboratory (ORNL) phantom series (e.g., salivary glands). Recently, the investigators at University of Florida have updated the series of ORNL phantoms by implementing new organ models and adopting organ-specific elemental composition and densities. In this study, the effective dose changes caused by the transition from the current recommendation of ICRP Publication 60 to the 2006 draft recommendations were investigated for external photon irradiation across the range of ICRP reference ages (newborn, 1-year, 5-year, 10-year, 15-year and adult) and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO). Organ-absorbed doses were calculated by implementing the revised ORNL phantoms in the Monte Carlo radiation transport code, MCNPX2.5, after which effective doses were calculated under the 1990 and draft 2006 evaluation schemes of the ICRP. Effective doses calculated under the 2006 draft scheme were slightly higher than estimated under ICRP Publication 60 methods for all irradiation geometries exclusive of the AP geometry where an opposite trend was observed. The effective doses of the adult phantom were more greatly affected by the change in tissue weighting factors than that seen within the paediatric members of the phantom series. Additionally, dose conversion

  15. Investigation of factors influencing radioiodine (131I) biokinetics in patients with benign thyroid disease using nonlinear mixed effects approach.

    PubMed

    Topić Vučenović, Valentina; Rajkovača, Zvezdana; Jelić, Dijana; Stanimirović, Dragi; Vuleta, Goran; Miljković, Branislava; Vučićević, Katarina

    2018-05-13

    Radioiodine ( 131 I) therapy is the common treatment option for benign thyroid diseases. The objective of this study was to characterize 131 I biokinetics in patients with benign thyroid disease and to investigate and quantify the influence of patients' demographic and clinical characteristics on intra-thyroidal 131 I kinetics by developing a population model. Population pharmacokinetic analysis was performed using a nonlinear mixed effects approach. Data sets of 345 adult patients with benign thyroid disease, retrospectively collected from patients' medical records, were evaluated in the analysis. The two-compartment model of 131 I biokinetics representing the blood compartment and thyroid gland was used as the structural model. Results of the study indicate that the rate constant of the uptake of 131 I into the thyroid (k tu ) is significantly influenced by clinical diagnosis, age, functional thyroid volume, free thyroxine in plasma (fT 4 ), use of anti-thyroid drugs, and time of discontinuation of therapy before administration of the radioiodine (THDT), while the effective half-life of 131 I is affected by the age of the patients. Inclusion of the covariates in the base model resulted in a decrease of the between subject variability for k tu from 91 (3.9) to 53.9 (4.5)%. This is the first population model that accounts for the influence of fT 4 and THDT on radioiodine kinetics. The model could be used for further investigations into the correlation between thyroidal exposure to 131 I and the outcome of radioiodine therapy of benign thyroid disease as well as the development of dosing recommendations.

  16. Amiodarone biokinetics, the formation of its major oxidative metabolite and neurotoxicity after acute and repeated exposure of brain cell cultures.

    PubMed

    Pomponio, Giuliana; Zurich, Marie-Gabrielle; Schultz, Luise; Weiss, Dieter G; Romanelli, Luca; Gramowski-Voss, Alexandra; Di Consiglio, Emma; Testai, Emanuela

    2015-12-25

    The difficulty in mimicking nervous system complexity and cell-cell interactions as well as the lack of kinetics information has limited the use of in vitro neurotoxicity data. Here, we assessed the biokinetic profile as well as the neurotoxicity of Amiodarone after acute and repeated exposure in two advanced rodent brain cell culture models, consisting of both neurons and glial cells organized in 2 or 3 dimensions to mimic the brain histiotypic structure and function. A strategy was applied to evidence the abiotic processes possibly affecting Amiodarone in vitro bioavailability, showing its ability to adsorb to the plastic devices. At clinically relevant Amiodarone concentrations, known to induce neurotoxicity in some patients during therapeutic treatment, a complete uptake was observed in both models in 24 h, after single exposure. After repeated treatments, bioaccumulation was observed, especially in the 3D cell model, together with a greater alteration of neurotoxicity markers. After 14 days, Amiodarone major oxidative metabolite (mono-N-desethylamiodarone) was detected at limited levels, indicating the presence of active drug metabolism enzymes (i.e. cytochrome P450) in both models. The assessment of biokinetics provides useful information on the relevance of in vitro toxicity data and should be considered in the design of an Integrated Testing Strategy aimed to identify specific neurotoxic alerts, and to improve the neurotoxicity assay predictivity for human acute and repeated exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. ICRP draft publication on 'radiological protection against radon exposure'.

    PubMed

    Lecomte, J-F

    2014-07-01

    To control the main part of radon exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) recommends an integrated approach focused as far as possible on the management of the building or location in which radon exposure occurs whatever the purpose of the building and the types of its occupants. This approach is based on the optimisation principle and a graded approach according to the degree of responsibilities at stake, notably in workplace, as well as the level of ambition of the national authorities. The report which is being developed by the Committee 4 is considering the recently consolidated ICRP general recommendations, the new scientific knowledge about the radon risk and the experience gained by many organisations and countries in the control of radon exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Assessment of Dose to the Nursing Infant from Radionuclides in Breast Milk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Eckerman, Keith F

    A computer software package was developed to predict tissue doses to an infant due to intake of radionuclides in breast milk based on bioassay measurements and exposure data for the mother. The package is intended mainly to aid in decisions regarding the safety of breast feeding by a mother who has been acutely exposed to a radionuclide during lactation or pregnancy, but it may be applied to previous intakes during the mother s adult life. The package includes biokinetic and dosimetric information needed to address intake of Co-60, Sr-90, Cs-134, Cs-137, Ir-192, Pu-238, Pu-239, Am-241, or Cf-252 by the mother.more » It has been designed so that the library of biokinetic and dosimetric files can be expanded to address a more comprehensive set of radionuclides without modifying the basic computational module. The methods and models build on the approach used in Publication 95 of the International Commission on Radiological Protection (ICRP 2004), Doses to Infants from Ingestion of Radionuclides in Mothers Milk . The software package allows input of case-specific information or judgments such as chemical form or particle size of an inhaled aerosol. The package is expected to be more suitable than ICRP Publication 95 for dose assessment for real events or realistic planning scenarios in which measurements of the mother s excretion or body burden are available.« less

  19. Strontium-90 Biokinetics from Simulated Wound Intakes in Non-human Primates Compared with Combined Model Predictions from National Council on Radiation Protection and Measurements Report 156 and International Commission on Radiological Protection Publication 67.

    PubMed

    Allen, Mark B; Brey, Richard R; Gesell, Thomas; Derryberry, Dewayne; Poudel, Deepesh

    2016-01-01

    This study had a goal to evaluate the predictive capabilities of the National Council on Radiation Protection and Measurements (NCRP) wound model coupled to the International Commission on Radiological Protection (ICRP) systemic model for 90Sr-contaminated wounds using non-human primate data. Studies were conducted on 13 macaque (Macaca mulatta) monkeys, each receiving one-time intramuscular injections of 90Sr solution. Urine and feces samples were collected up to 28 d post-injection and analyzed for 90Sr activity. Integrated Modules for Bioassay Analysis (IMBA) software was configured with default NCRP and ICRP model transfer coefficients to calculate predicted 90Sr intake via the wound based on the radioactivity measured in bioassay samples. The default parameters of the combined models produced adequate fits of the bioassay data, but maximum likelihood predictions of intake were overestimated by a factor of 1.0 to 2.9 when bioassay data were used as predictors. Skeletal retention was also over-predicted, suggesting an underestimation of the excretion fraction. Bayesian statistics and Monte Carlo sampling were applied using IMBA to vary the default parameters, producing updated transfer coefficients for individual monkeys that improved model fit and predicted intake and skeletal retention. The geometric means of the optimized transfer rates for the 11 cases were computed, and these optimized sample population parameters were tested on two independent monkey cases and on the 11 monkeys from which the optimized parameters were derived. The optimized model parameters did not improve the model fit in most cases, and the predicted skeletal activity produced improvements in three of the 11 cases. The optimized parameters improved the predicted intake in all cases but still over-predicted the intake by an average of 50%. The results suggest that the modified transfer rates were not always an improvement over the default NCRP and ICRP model values.

  20. Depth investigation of rapid sand filters for drinking water production reveals strong stratification in nitrification biokinetic behavior.

    PubMed

    Tatari, K; Smets, B F; Albrechtsen, H-J

    2016-09-15

    The biokinetic behavior of NH4(+) removal was investigated at different depths of a rapid sand filter treating groundwater for drinking water preparation. Filter materials from the top, middle and bottom layers of a full-scale filter were exposed to various controlled NH4(+) loadings in a continuous-flow lab-scale assay. NH4(+) removal capacity, estimated from short term loading up-shifts, was at least 10 times higher in the top than in the middle and bottom filter layers, consistent with the stratification of Ammonium Oxidizing Bacteria (AOB). AOB density increased consistently with the NH4(+) removal rate, indicating their primarily role in nitrification under the imposed experimental conditions. The maximum AOB cell specific NH4(+) removal rate observed at the bottom was at least 3 times lower compared to the top and middle layers. Additionally, a significant up-shift capacity (4.6 and 3.5 times) was displayed from the top and middle layers, but not from the bottom layer at increased loading conditions. Hence, AOB with different physiological responses were active at the different depths. The biokinetic analysis predicted that despite the low NH4(+) removal capacity at the bottom layer, the entire filter is able to cope with a 4-fold instantaneous loading increase without compromising the effluent NH4(+). Ultimately, this filter up-shift capacity was limited by the density of AOB and their biokinetic behavior, both of which were strongly stratified. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. WORKER INHALATION DOSE COEFFICIENTS FOR RADIONUCLIDES NOT PREVIOUSLY IDENTIFIED IN ICRP PUBLICATION 68

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaughlin, David A; Schwahn, Scott O

    2011-01-01

    While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory s Spallation Neutron Source.

  2. A compartmental model of uranium in human hair for protracted ingestion of natural uranium in drinking water.

    PubMed

    Li, W B; Karpas, Z; Salonen, L; Kurttio, P; Muikku, M; Wahl, W; Höllriegl, V; Hoeschen, C; Oeh, U

    2009-06-01

    To predict uranium in human hair due to chronic exposure through drinking water, a compartment representing human hair was added into the uranium biokinetic model developed by the International Commission on Radiological Protection (ICRP). The hair compartmental model was used to predict uranium excretion in human hair as a bioassay indicator due to elevated uranium intakes. Two excretion pathways, one starting from the compartment of plasma and the other from the compartment of intermediate turnover soft tissue, are assumed to transfer uranium to the compartment of hair. The transfer rate was determined from reported uranium contents in urine and in hair, taking into account the hair growth rate of 0.1 g d(-1). The fractional absorption in the gastrointestinal tract of 0.6% was found to fit best to describe the measured uranium levels among the users of drilled wells in Finland. The ingestion dose coefficient for (238)U, which includes its progeny of (234)Th, (234m)Pa, and (234)Pa, was calculated equal to 1.3 x 10(-8) Sv Bq(-1) according to the hair compartmental model. This estimate is smaller than the value of 4.5 x 10(-8) Sv Bq(-1) published by ICRP for the members of the public. In this new model, excretion of uranium through urine is better represented when excretion to the hair compartment is accounted for and hair analysis can provide a means for assessing the internal body burden of uranium. The model is applicable for chronic exposure as well as for an acute exposure incident. In the latter case, the hair sample can be collected and analyzed even several days after the incident, whereas urinalysis requires sample collection shortly after the exposure. The model developed in this study applies to ingestion intakes of uranium.

  3. Biokinetics of yttrium and comparison with its geochemical twin holmium

    DOE PAGES

    Leggett, Rich

    2017-06-01

    The transition metal yttrium (Y, atomic number 39) is chemically similar to elements in the lanthanide family (atomic numbers 57-71, lanthanum through lutetium) and is always present with the lanthanides in rare earth ores. Yttrium and the lanthanide holmium are particularly close chemical and physical analogues and are referred to as geochemical twins because they typically show little fractionation in geological material. Extensive measurements on rocks, soils, and meteorites indicate that the Y/Ho mass concentration ratio rarely falls far from the “chondritic” or “solar system” ratio of ~26. Our paper presents a new biokinetic model for yttrium in adult humansmore » and examines whether yttrium and holmium may be biological as well as geochemical twins. Collected data on yttrium and holmium in plants and human tissues do not allow precise derivations of Y/Ho concentration ratios but with occasional exceptions yield ratios that are reasonably consistent with chondritic values. Predictions of the time-dependent behavior of yttrium in adult humans based on the yttrium model presented here closely approximate predictions of the behavior of holmium based on a previously developed model for holmium. We know that yttrium and holmium are close biological analogues, but the available comparative data are too limited and imprecise to reveal whether there are any significant differences in their biological behavior.« less

  4. Controlling intake of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne; Eckerman, Keith F; McGinn, Wilson

    2012-01-01

    This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for settingmore » standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.« less

  5. ICRP Publication 132: Radiological Protection from Cosmic Radiation in Aviation.

    PubMed

    Lochard, J; Bartlett, D T; Rühm, W; Yasuda, H; Bottollier-Depois, J-F

    2016-06-01

    In this publication, the International Commission on Radiological Protection (ICRP) provides updated guidance on radiological protection from cosmic radiation in aviation, taking into account the current ICRP system of radiological protection, the latest available data on exposures in aviation, and experience gained worldwide in the management of exposures in aviation. The publication describes the origins of cosmic radiation, how it exposes passengers and aircraft crew, the basic radiological protection principles that apply to this existing exposure situation, and the available protective actions. For implementation of the optimisation principle, the Commission recommends a graded approach proportionate to the level of exposure that may be received by individuals. The objective is to keep the exposure of the most exposed individuals to a reasonable level. The Commission also recommends that information be disseminated to raise awareness about cosmic radiation, and to support informed decisions among concerned stakeholders.

  6. ICRP Publication 107. Nuclear decay data for dosimetric calculations.

    PubMed

    Eckerman, K; Endo, A

    2008-01-01

    In this report, the Commission provides an electronic database of the physical data needed in calculations of radionuclide-specific protection and operational quantities. This database supersedes the data of Publication 38 (ICRP, 1983), and will be used in future ICRP publications of dose coefficients for the intake of or exposure to radionuclides in the workplace and the environment.The database contains information on the half-lives, decay chains, and yields and energies of radiations emitted in nuclear transformations of 1252 radionuclides of 97 elements. The CD accompanying the publication provides electronic access to complete tables of the emitted radiations, as well as the beta and neutron spectra. The database has been constructed such that user-developed software can extract the data needed for further calculations of a radionuclide of interest. A Windows-based application is provided to display summary information on a user-specified radionuclide, as well as the general characterisation of the nuclides contained in the database. In addition, the application provides a means by which the user can export the emissions of a specified radionuclide for use in subsequent calculations.

  7. Implementation of iodine biokinetic model for interpreting I-131 contamination in breast milk after the Fukushima nuclear disaster

    NASA Astrophysics Data System (ADS)

    Tani, Kotaro; Kurihara, Osamu; Kim, Eunjoo; Yoshida, Satoshi; Sakai, Kazuo; Akashi, Makoto

    2015-07-01

    After the accident at the Fukushima Daiichi Nuclear Power Plant run by Tokyo Electric Power Company in 2011, breast milk samples obtained from volunteers living in Fukushima and neighboring prefectures were examined and small amounts of I-131 (2.2-36.3 Bq/kg) were detected in some samples. In this work, the I-131 concentrations in breast milk from nursing mothers in Ibaraki prefecture were calculated based on the iodine biokinetic model during lactation together with time-variable intake scenarios by inhalation of ambient air and ingestion of tap water, using the authors’ code. The calculated I-131 concentrations in breast milk generally agreed with those measured for the volunteers. Based on the results, thyroid equivalent doses to breast-fed infants were estimated for each place of residence of the volunteers on the assumption that these infants consumed 800 ml of breast milk every day, resulting in 10-11 mSv for Mito and Kasama cities and 1.1-1.8 mSv for Tsukuba and Moriya cities. It was suggested that breast milk consumption could be a major contributor to internal dose of breast-fed infants in areas with mild I-131 pollution; however, further studies considering personal behavior surveys would be necessary to estimate individual doses.

  8. Implementation of iodine biokinetic model for interpreting I-131 contamination in breast milk after the Fukushima nuclear disaster.

    PubMed

    Tani, Kotaro; Kurihara, Osamu; Kim, Eunjoo; Yoshida, Satoshi; Sakai, Kazuo; Akashi, Makoto

    2015-07-22

    After the accident at the Fukushima Daiichi Nuclear Power Plant run by Tokyo Electric Power Company in 2011, breast milk samples obtained from volunteers living in Fukushima and neighboring prefectures were examined and small amounts of I-131 (2.2-36.3 Bq/kg) were detected in some samples. In this work, the I-131 concentrations in breast milk from nursing mothers in Ibaraki prefecture were calculated based on the iodine biokinetic model during lactation together with time-variable intake scenarios by inhalation of ambient air and ingestion of tap water, using the authors' code. The calculated I-131 concentrations in breast milk generally agreed with those measured for the volunteers. Based on the results, thyroid equivalent doses to breast-fed infants were estimated for each place of residence of the volunteers on the assumption that these infants consumed 800 ml of breast milk every day, resulting in 10-11 mSv for Mito and Kasama cities and 1.1-1.8 mSv for Tsukuba and Moriya cities. It was suggested that breast milk consumption could be a major contributor to internal dose of breast-fed infants in areas with mild I-131 pollution; however, further studies considering personal behavior surveys would be necessary to estimate individual doses.

  9. INDOS: conversational computer codes to implement ICRP-10-10A models for estimation of internal radiation dose to man

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killough, G.G.; Rohwer, P.S.

    1974-03-01

    INDOS1, INDOS2, and INDOS3 (the INDOS codes) are conversational FORTRAN IV programs, implemented for use in time-sharing mode on the ORNL PDP-10 System. These codes use ICRP10-10A models to estimate the radiation dose to an organ of the body of Reference Man resulting from the ingestion or inhalation of any one of various radionuclides. Two patterns of intake are simulated: intakes at discrete times and continuous intake at a constant rate. The IND0S codes provide tabular output of dose rate and dose vs time, graphical output of dose vs time, and punched-card output of organ burden and dose vs time.more » The models of internal dose calculation are discussed and instructions for the use of the INDOS codes are provided. The INDOS codes are available from the Radiation Shielding Information Center, Oak Ridge National Laboratory, P. O. Box X, Oak Ridge, Tennessee 37830. (auth)« less

  10. Biokinetics and dosimetry in patients of 99mTc-EDDA/HYNIC-Tyr3-octreotide prepared from lyophilized kits.

    PubMed

    González-Vázquez, Armando; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Gutiérrez-García, Zohar

    2006-07-01

    99mTc-EDDA/HYNIC-Tyr3-octreotide (99mTc-HYNIC-TOC) has shown high in vitro and in vivo stability, rapid background clearance and rapid detection of somatostatin receptor-positive tumors. The aim of this study was to establish a biokinetic model for 99mTc-HYNIC-TOC prepared from lyophilized kits, and to evaluate its dosimetry as a tumor imaging agent in patients with histologically confirmed neuroendocrine tumors. Whole-body images from eight patients were acquired at 5, 60, 90, 180 min and 24 h after 99mTc-HYNIC-TOC administration obtained from instant freeze-dried kit formulations with radiochemical purities >95%. Regions of interest (ROIs) were drawn around source organs on each time frame. The same set of ROIs was used for all eight scans and the count per minute (cpm) of each ROI was converted to activity using the conjugate view counting method. The image sequence was used to extrapolate 99mTc-HYNIC-TOC time-activity curves in each organ, to adjust a biokinetic model using the SAAM software, and to calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. Images showed an average tumor/blood (heart) ratio of 4.3+/-0.7 in receptor-positive tumors at 1 h. The mean radiation absorbed dose calculated for a study using 740 MBq was 24, 21.5, 5.5 and 1.0 mSv for spleen, kidneys, liver and bone marrow respectively and the effective dose was 4.4 mSv.

  11. ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.

    PubMed

    Vano, E; Faulkner, K

    2005-01-01

    The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.

  12. ICRP PUBLICATION 122: radiological protection in geological disposal of long-lived solid radioactive waste.

    PubMed

    Weiss, W; Larsson, C-M; McKenney, C; Minon, J-P; Mobbs, S; Schneider, T; Umeki, H; Hilden, W; Pescatore, C; Vesterlind, M

    2013-06-01

    This report updates and consolidates previous recommendations of the International Commission on Radiological Protection (ICRP) related to solid waste disposal (ICRP, 1985, 1997b, 1998). The recommendations given apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the ICRP system of radiological protection described in Publication 103 (ICRP, 2007) can be applied in the context of the geological disposal of long-lived solid radioactive waste. Although the report is written as a standalone document, previous ICRP recommendations not dealt with in depth in the report are still valid. The 2007 ICRP system of radiological protection evolves from the previous process-based protection approach relying on the distinction between practices and interventions by moving to an approach based on the distinction between three types of exposure situation: planned, emergency and existing. The Recommendations maintains the Commission's three fundamental principles of radiological protection namely: justification, optimisation of protection and the application of dose limits. They also maintain the current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They re-enforce the principle of optimisation of radiological protection, which applies in a similar way to all exposure situations, subject to restrictions on individual doses: constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment. This report describes the different stages in the life time of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that

  13. Distribution and biokinetic analysis of 210Pb and 210Po in poultry due to ingestion of dicalcium phosphate.

    PubMed

    Casacuberta, N; Traversa, F L; Masqué, P; Garcia-Orellana, J; Anguita, M; Gasa, J; Garcia-Tenorio, R

    2010-09-15

    Dicalcium phosphate (DCP) is used as a calcium supplement for food producing animals (i.e., cattle, poultry and pig). When DCP is produced via wet acid digestion of the phosphate rock and depending on the acid used in the industrial process, the final product can result in enhanced (210)Pb and (210)Po specific activities (approximately 2000 Bq.kg(-1)). Both (210)Pb and (210)Po are of great interest because their contribution to the dose received by ingestion is potentially large. The aims of this work are to examine the accumulation of (210)Pb and (210)Po in chicken tissues during the first 42 days of life and to build a suitable single-compartment biokinetic model to understand the behavior of both radionuclides within the entire animal using the experimental results. Three commercial corn-soybean-based diets containing different amounts and sources of DCP were fed to broilers during a period of 42 days. The results show that diets containing enhanced concentrations of (210)Pb and (210)Po lead to larger specific accumulation in broiler tissues compared to the blank diet. Radionuclides do not accumulate homogeneously within the animal body: (210)Pb follows the calcium pathways to some extent and accumulates largely in bones, while (210)Po accumulates to a large extent in liver and kidneys. However, the total amount of radionuclide accumulation in tissues is small compared to the amounts excreted in feces. The single-compartment non-linear biokinetic model proposed here for (210)Pb and (210)Po in the whole animal takes into account the size evolution and is self-consistent in that no fitting parameterization of intake and excretions rates is required. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Exposure assessment of natural uranium from drinking water.

    PubMed

    Jakhu, Rajan; Mehra, Rohit; Mittal, H M

    2016-12-08

    The uranium concentration in the drinking water of the residents of the Jaipur and Ajmer districts of Rajasthan has been measured for exposure assessment. The daily intake of uranium from the drinking water for the residents of the study area is found to vary from 0.4 to 123.9 μg per day. For the average uranium ingestion rate of 35.2 μg per day for a long term exposure period of 60 years, estimations have been made for the retention of uranium in different body organs and its excretion with time using ICRP's biokinetic model of uranium. Radioactive and chemical toxicity of uranium has been reported and discussed in detail in the present manuscript.

  15. The evolution of the international system of radiological protection: stakeholder views from the 1st and 2nd NEA/ICRP fora.

    PubMed

    Lazo, Ted

    2003-12-01

    The Nuclear Energy Agency's (NEA's) Committee on Radiological Protection and Public Health (CRPPH) has collaborated closely with the ICRP in its efforts to develop new recommendations for radiological protection at the start of the 21st century. As part of this effort, the NEA organised, in collaboration with the ICRP, two fora to discuss the radiological protection of the environment (Taormina, February 2002) and the future policy for radiological protection (Lanzarote, April 2003). Both these meetings were attended by a broad representation of stakeholders. The CRPPH and other stakeholders universally appreciated the opportunity to speak directly with the ICRP on these important subjects. This report summarises the main conclusions made during these two meetings to advance the deliberations of the ICRP to create a new set of recommendations responsive to stakeholder needs, firmly rooted in science, and that can be implemented in a timely, efficient and cost-effective manner.

  16. Radiation safety concerns for pregnant or breast feeding patients. The positions of the NCRP and the ICRP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meinhold, C.B.

    For many years, protecting the fetus has been a concern of the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP). Early recommendations focused on the possibility of a wide variety of detrimental developmental effects while later recommendations focused on the potential for severe mental retardation and/or reduction in the intelligence quotient (I.Q.). The latest recommendations also note that the risk of cancer for the fetus is probably two to three times greater per Sv than in the adult. For all these reasons, the NCRP and the ICRP have provided guidance to physiciansmore » on taking all reasonable steps to ascertain whether any woman requiring a radiological or nuclear medicine procedure is pregnant or nursing a child. The NCRP and the ICRP also advise the clinician to postpone such procedures until after delivery or cessation of nursing, if possible.« less

  17. Comparative analysis of dosimetry parameters for nuclear medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toohey, R.E.; Stabin, M.G.

    For years many have employed the concept of ``total-body dose`` or ``whole-body dose,`` i.e., the total energy deposited in the body divided by the mass of the body, when evaluating the risks of different nuclear medicine procedures. The effective dose equivalent (H{sub E}), first described in ICRP Publication 26, has been accepted by some as a better quantity to use in evaluating the total risk of a procedure, but its use has been criticized by others primarily because the tissue weighting factors were intended for use in the radiation worker, rather than the nuclear medicine patient population. Nevertheless, in ICRPmore » Publication 52, the ICRP has suggested that the H{sub E} may be used in nuclear medicine. The ICRP also has published a compendium of dose estimates, including H{sub E} values, for various nuclear medicine procedures at various ages in ICRP Publication 53. The effective dose (E) of ICRP Publication 60 is perhaps more suitable for use in nuclear medicine, with tissue weighting factors based on the entire population. Other comparisons of H{sub E} and E have been published. The authors have used the program MIRDOSE 3.1 to compute total-body dose, H{sub E}, and E for 62 radiopharmaceutical procedures, based on the best current biokinetic data available.« less

  18. Biokinetic and dosimetric investigations of 14C-labeled substances in man using AMS

    NASA Astrophysics Data System (ADS)

    Mattsson, Sören; Gunnarsson, Mikael; Svegborn, Sigrid Leide; Nosslin, Bertil; Nilsson, Lars-Erik; Thorsson, Ola; Valind, Sven; Åberg, Magnus; Östberg, Henrik; Hellborg, Ragnar; Stenström, Kristina; Erlandsson, Bengt; Faarinen, Mikko; Kiisk, Madis; Magnusson, Carl-Erik; Persson, Per; Skog, Göran

    2001-07-01

    Up to now, radiation dose estimates from radiopharmaceuticals, labeled with pure β-emitting radionuclides, e.g., 14C or 3H have been very uncertain. Using accelerator mass spectrometry (AMS) we have derived new and improved data for 14C-triolein and 14C-urea and are currently running a program related to the biokinetics and dosimetry of 14C-glycocholic acid and 14C-xylose. The results of our investigations have made it possible to widen the indications for the clinical use of the 14C-urea test for Helicobacter pylori infection in children. The use of ultra-low activities, which is possible with AMS (down to 1/1000 of that used for liquid scintillation counting), has opened the possibility for metabolic investigations on children as well as on other sensitive patient groups like new-borns, and pregnant or breast-feeding women. Using the full potential of AMS, new 14C-labeled drugs could be tested on humans at a much earlier stage than today, avoiding uncertain extrapolations from animal models.

  19. Plasma Retention and Systemic Kinetics of 90Sr Intramuscularly Injected in Female Nonhuman Primates

    DOE PAGES

    Poudel, Deepesh; Klumpp, John A.; Bertelli, Luiz; ...

    2017-08-01

    Thirteen female Rhesus macaques were intramuscularly injected with 90Sr(NO 3) 2 diluted in sodium citrate solution. The biokinetic data from these animals were compared against the predictions of the NCRP 156 wound models combined with the ICRP systemic models. We observed observed that the activities measured in plasma of these nonhuman primates (NHPs) were consistently lower than those predicted by the default human biokinetic models. The urinary excretion from the NHPs at times immediately after injection was much greater than that in humans. The fecal excretion rates were found to be in relatively better agreement with humans. Similarly, the activitiesmore » retained in the skeleton of the NHPs were lower than that in humans. These differences were attributed to the higher calcium diet of the NHPs (0.03 to 0.12 g/d/kg body weight) compared to that of humans. These observations were consistent with the early animal and human studies that showed the effect of calcium on strontium metabolism, specifically urinary excretion. Strontium is preferentially filtered at a much higher rate in kidneys than calcium because it is less completely bound to protein than is calcium. Furthermore, these differences, along with large inter-animal variability, should be considered when estimating the behavior of Sr in humans from the metabolic data in animals or vice-versa.« less

  20. Plasma Retention and Systemic Kinetics of 90Sr Intramuscularly Injected in Female Nonhuman Primates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poudel, Deepesh; Klumpp, John A.; Bertelli, Luiz

    Thirteen female Rhesus macaques were intramuscularly injected with 90Sr(NO 3) 2 diluted in sodium citrate solution. The biokinetic data from these animals were compared against the predictions of the NCRP 156 wound models combined with the ICRP systemic models. We observed observed that the activities measured in plasma of these nonhuman primates (NHPs) were consistently lower than those predicted by the default human biokinetic models. The urinary excretion from the NHPs at times immediately after injection was much greater than that in humans. The fecal excretion rates were found to be in relatively better agreement with humans. Similarly, the activitiesmore » retained in the skeleton of the NHPs were lower than that in humans. These differences were attributed to the higher calcium diet of the NHPs (0.03 to 0.12 g/d/kg body weight) compared to that of humans. These observations were consistent with the early animal and human studies that showed the effect of calcium on strontium metabolism, specifically urinary excretion. Strontium is preferentially filtered at a much higher rate in kidneys than calcium because it is less completely bound to protein than is calcium. Furthermore, these differences, along with large inter-animal variability, should be considered when estimating the behavior of Sr in humans from the metabolic data in animals or vice-versa.« less

  1. Report of ICRP Task Group 80: 'radiological protection in geological disposal of long-lived solid radioactive waste'.

    PubMed

    Weiss, W

    2012-01-01

    The report of International Commission on Radiological Protection (ICRP) Task Group 80 entitled 'Radiological protection in geological disposal of long-lived solid radioactive waste' updates and consolidates previous ICRP recommendations related to solid waste disposal (ICRP Publications 46, 77, and 81). The recommendations given in this report apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the 2007 system of radiological protection, described in ICRP Publication 103, can be applied in the context of the geological disposal of long-lived solid radioactive waste. The report is written as a self-standing document. It describes the different stages in the lifetime of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences application of the protection system over the different phases in the lifetime of a disposal facility is the level of oversight that is present. The level of oversight affects the capability to reduce or avoid exposures. Three main time frames have to be considered for the purpose of radiological protection: time of direct oversight when the disposal facility is being implemented and active oversight is taking place; time of indirect oversight when the disposal facility is sealed and indirect oversight is being exercised to provide additional assurance on behalf of the population; and time of no oversight when oversight is no longer exercised because memory is lost. Copyright © 2012. Published by Elsevier Ltd.

  2. Toward a general physiologically-based pharmacokinetic model for intravenously injected nanoparticles.

    PubMed

    Carlander, Ulrika; Li, Dingsheng; Jolliet, Olivier; Emond, Claude; Johanson, Gunnar

    2016-01-01

    To assess the potential toxicity of nanoparticles (NPs), information concerning their uptake and disposition (biokinetics) is essential. Experience with industrial chemicals and pharmaceutical drugs reveals that biokinetics can be described and predicted accurately by physiologically-based pharmacokinetic (PBPK) modeling. The nano PBPK models developed to date all concern a single type of NP. Our aim here was to extend a recent model for pegylated polyacrylamide NP in order to develop a more general PBPK model for nondegradable NPs injected intravenously into rats. The same model and physiological parameters were applied to pegylated polyacrylamide, uncoated polyacrylamide, gold, and titanium dioxide NPs, whereas NP-specific parameters were chosen on the basis of the best fit to the experimental time-courses of NP accumulation in various tissues. Our model describes the biokinetic behavior of all four types of NPs adequately, despite extensive differences in this behavior as well as in their physicochemical properties. In addition, this simulation demonstrated that the dose exerts a profound impact on the biokinetics, since saturation of the phagocytic cells at higher doses becomes a major limiting step. The fitted model parameters that were most dependent on NP type included the blood:tissue coefficients of permeability and the rate constant for phagocytic uptake. Since only four types of NPs with several differences in characteristics (dose, size, charge, shape, and surface properties) were used, the relationship between these characteristics and the NP-dependent model parameters could not be elucidated and more experimental data are required in this context. In this connection, intravenous biodistribution studies with associated PBPK analyses would provide the most insight.

  3. WE-E-BRE-01: An Image-Based Skeletal Dosimetry Model for the ICRP Reference Adult Female - Internal Electron Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Reilly, S; Maynard, M; Marshall, E

    Purpose: Limitations seen in previous skeletal dosimetry models, which are still employed in commonly used software today, include the lack of consideration of electron escape and cross-fire from cortical bone, the modeling of infinite spongiosa, the disregard of the effect of varying cellularity on active marrow self-irradiation, and the lack of use of the more recent ICRP definition of a 50 micron surrogate tissue region for the osteoprogenitor cells - shallow marrow. These limitations were addressed in the present dosimetry model. Methods: Electron transport was completed to determine specific absorbed fractions to active marrow and shallow marrow of the skeletalmore » regions of the adult female. The bone macrostructure was obtained from the whole-body hybrid computational phantom of the UF series of reference phantoms, while the bone microstructure was derived from microCT images of skeletal region samples taken from a 45 year-old female cadaver. The target tissue regions were active marrow and shallow marrow. The source tissues were active marrow, inactive marrow, trabecular bone volume, trabecular bone surfaces, cortical bone volume and cortical bone surfaces. The marrow cellularity was varied from 10 to 100 percent for active marrow self-irradiation. A total of 33 discrete electron energies, ranging from 1 keV to 10 MeV, were either simulated or modeled analytically. Results: The method of combining macro- and microstructure absorbed fractions calculated using MCNPX electron transport was found to yield results similar to those determined with the PIRT model for the UF adult male in the Hough et al. study. Conclusion: The calculated skeletal averaged absorbed fractions for each source-target combination were found to follow similar trends of more recent dosimetry models (image-based models) and did not follow current models used in nuclear medicine dosimetry at high energies (due to that models use of an infinite expanse of trabecular spongiosa)« less

  4. A novel bench-scale column assay to investigate site-specific nitrification biokinetics in biological rapid sand filters.

    PubMed

    Tatari, K; Smets, B F; Albrechtsen, H-J

    2013-10-15

    A bench-scale assay was developed to obtain site-specific nitrification biokinetic information from biological rapid sand filters employed in groundwater treatment. The experimental set-up uses granular material subsampled from a full-scale filter, packed in a column, and operated with controlled and continuous hydraulic and ammonium loading. Flowrates and flow recirculation around the column are chosen to mimic full-scale hydrodynamic conditions, and minimize axial gradients. A reference ammonium loading rate is calculated based on the average loading experienced in the active zone of the full-scale filter. Effluent concentrations of ammonium are analyzed when the bench-scale column is subject to reference loading, from which removal rates are calculated. Subsequently, removal rates above the reference loading are measured by imposing short-term loading variations. A critical loading rate corresponding to the maximum removal rate can be inferred. The assay was successfully applied to characterize biokinetic behavior from a test rapid sand filter; removal rates at reference loading matched those observed from full-scale observations, while a maximum removal capacity of 6.9 g NH4(+)-N/m(3) packed sand/h could easily be determined at 7.5 g NH4(+)-N/m(3) packed sand/h. This assay, with conditions reflecting full-scale observations, and where the biological activity is subject to minimal physical disturbance, provides a simple and fast, yet powerful tool to gain insight in nitrification kinetics in rapid sand filters. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Calculated organ doses for Mayak production association central hall using ICRP and MCNP.

    PubMed

    Choe, Dong-Ok; Shelkey, Brenda N; Wilde, Justin L; Walk, Heidi A; Slaughter, David M

    2003-03-01

    As part of an ongoing dose reconstruction project, equivalent organ dose rates from photons and neutrons were estimated using the energy spectra measured in the central hall above the graphite reactor core located in the Russian Mayak Production Association facility. Reconstruction of the work environment was necessary due to the lack of personal dosimeter data for neutrons in the time period prior to 1987. A typical worker scenario for the central hall was developed for the Monte Carlo Neutron Photon-4B (MCNP) code. The resultant equivalent dose rates for neutrons and photons were compared with the equivalent dose rates derived from calculations using the conversion coefficients in the International Commission on Radiological Protection Publications 51 and 74 in order to validate the model scenario for this Russian facility. The MCNP results were in good agreement with the results of the ICRP publications indicating the modeling scenario was consistent with actual work conditions given the spectra provided. The MCNP code will allow for additional orientations to accurately reflect source locations.

  6. ICRP Publication 138: Ethical Foundations of the System of Radiological Protection.

    PubMed

    Cho, K-W; Cantone, M-C; Kurihara-Saio, C; Le Guen, B; Martinez, N; Oughton, D; Schneider, T; Toohey, R; ZöLzer, F

    2018-02-01

    Despite a longstanding recognition that radiological protection is not only a matter of science, but also ethics, ICRP publications have rarely addressed the ethical foundations of the system of radiological protection explicitly. The purpose of this publication is to describe how the Commission has relied on ethical values, either intentionally or indirectly, in developing the system of radiological protection with the objective of presenting a coherent view of how ethics is part of this system. In so doing, it helps to clarify the inherent value judgements made in achieving the aim of the radiological protection system as underlined by the Commission in Publication 103. Although primarily addressed to the radiological protection community, this publication is also intended to address authorities, operators, workers, medical professionals, patients, the public, and its representatives (e.g. NGOs) acting in the interest of the protection of people and the environment. This publication provides the key steps concerning the scientific, ethical, and practical evolutions of the system of radiological protection since the first ICRP publication in 1928. It then describes the four core ethical values underpinning the present system: beneficence/ non-maleficence, prudence, justice, and dignity. It also discusses how these core ethical values relate to the principles of radiological protection, namely justification, optimisation, and limitation. The publication finally addresses key procedural values that are required for the practical implementation of the system, focusing on accountability, transparency, and inclusiveness. The Commission sees this publication as a founding document to be elaborated further in different situations and circumstances.

  7. Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.

    PubMed

    Sato, Tatsuhiko; Endo, Akira; Zankl, Maria; Petoussi-Henss, Nina; Niita, Koji

    2009-04-07

    The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation and tissue weighting factors, w(R) and w(T), respectively, as revised in ICRP Publication 103 were employed. The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of the absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. By comparing these data with the corresponding data for the effective dose, we found that the numerical compatibilities of the revised w(R) with the Q(L) and Q(y) relationships are fairly established. The calculated data of these dose conversion coefficients are indispensable for constructing the radiation protection systems based on the new recommendations given in ICRP103 for aircrews and astronauts, as well as for workers in accelerators and nuclear facilities.

  8. Biokinetics of Nanomaterials: the Role of Biopersistence.

    PubMed

    Laux, Peter; Riebeling, Christian; Booth, Andy M; Brain, Joseph D; Brunner, Josephine; Cerrillo, Cristina; Creutzenberg, Otto; Estrela-Lopis, Irina; Gebel, Thomas; Johanson, Gunnar; Jungnickel, Harald; Kock, Heiko; Tentschert, Jutta; Tlili, Ahmed; Schäffer, Andreas; Sips, Adriënne J A M; Yokel, Robert A; Luch, Andreas

    2017-04-01

    Nanotechnology risk management strategies and environmental regulations continue to rely on hazard and exposure assessment protocols developed for bulk materials, including larger size particles, while commercial application of nanomaterials (NMs) increases. In order to support and corroborate risk assessment of NMs for workers, consumers, and the environment it is crucial to establish the impact of biopersistence of NMs at realistic doses. In the future, such data will allow a more refined future categorization of NMs. Despite many experiments on NM characterization and numerous in vitro and in vivo studies, several questions remain unanswered including the influence of biopersistence on the toxicity of NMs. It is unclear which criteria to apply to characterize a NM as biopersistent. Detection and quantification of NMs, especially determination of their state, i.e., dissolution, aggregation, and agglomeration within biological matrices and other environments are still challenging tasks; moreover mechanisms of nanoparticle (NP) translocation and persistence remain critical gaps. This review summarizes the current understanding of NM biokinetics focusing on determinants of biopersistence. Thorough particle characterization in different exposure scenarios and biological matrices requires use of suitable analytical methods and is a prerequisite to understand biopersistence and for the development of appropriate dosimetry. Analytical tools that potentially can facilitate elucidation of key NM characteristics, such as ion beam microscopy (IBM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), are discussed in relation to their potential to advance the understanding of biopersistent NM kinetics. We conclude that a major requirement for future nanosafety research is the development and application of analytical tools to characterize NPs in different exposure scenarios and biological matrices.

  9. Quantitative biokinetics of titanium dioxide nanoparticles after intratracheal instillation in rats: Part 3.

    PubMed

    Kreyling, Wolfgang G; Holzwarth, Uwe; Haberl, Nadine; Kozempel, Ján; Wenk, Alexander; Hirn, Stephanie; Schleh, Carsten; Schäffler, Martin; Lipka, Jens; Semmler-Behnke, Manuela; Gibson, Neil

    2017-05-01

    The biokinetics of a size-selected fraction (70 nm median size) of commercially available and 48 V-radiolabeled [ 48 V]TiO 2 nanoparticles has been investigated in healthy adult female Wistar-Kyoto rats at retention time-points of 1 h, 4 h, 24 h, 7 d and 28 d after intratracheal instillation of a single dose of an aqueous [ 48 V]TiO 2 -nanoparticle suspension. A completely balanced quantitative biodistribution in all organs and tissues was obtained by applying typical [ 48 V]TiO 2 -nanoparticle doses in the range of 40-240 μg·kg -1 bodyweight and making use of the high sensitivity of the radiotracer technique. The [ 48 V]TiO 2 -nanoparticle content was corrected for residual blood retained in organs and tissues after exsanguination and for 48 V-ions not bound to TiO 2 -nanoparticles. About 4% of the initial peripheral lung dose passed through the air-blood-barrier after 1 h and were retained mainly in the carcass (4%); 0.3% after 28 d. Highest organ fractions of [ 48 V]TiO 2 -nanoparticles present in liver and kidneys remained constant (0.03%). [ 48 V]TiO 2 -nanoparticles which entered across the gut epithelium following fast and long-term clearance from the lungs via larynx increased from 5 to 20% of all translocated/absorbed [ 48 V]TiO 2 -nanoparticles. This contribution may account for 1/5 of the nanoparticle retention in some organs. After normalizing the fractions of retained [ 48 V]TiO 2 -nanoparticles to the fraction that reached systemic circulation, the biodistribution was compared with the biodistributions determined after IV-injection (Part 1) and gavage (GAV) (Part 2). The biokinetics patterns after IT-instillation and GAV were similar but both were distinctly different from the pattern after intravenous injection disproving the latter to be a suitable surrogate of the former applications. Considering that chronic occupational inhalation of relatively biopersistent TiO 2 -particles (including nanoparticles) and accumulation in

  10. Radiation-induced cataracts: the Health Protection Agency's response to the ICRP statement on tissue reactions and recommendation on the dose limit for the eye lens.

    PubMed

    Bouffler, Simon; Ainsbury, Elizabeth; Gilvin, Phil; Harrison, John

    2012-12-01

    This paper presents the response of the Health Protection Agency (HPA) to the 2011 statement from the International Commission on Radiological Protection (ICRP) on tissue reactions and recommendation of a reduced dose limit for the lens of the eye. The response takes the form of a brief review of the most recent epidemiological and mechanistic evidence. This is presented together with a discussion of dose limits in the context of the related risk and the current status of eye dosimetry, which is relevant for implementation of the limits. It is concluded that although further work is desirable to quantify better the risk at low doses and following protracted exposures, along with research into the mechanistic basis for radiation cataractogenesis to inform selection of risk projection models, the HPA endorses the conclusion reached by the ICRP in their 2011 statement that the equivalent dose limit for the lens of the eye should be reduced from 150 to 20 mSv per year, averaged over a five year period, with no year's dose exceeding 50 mSv.

  11. Construction of new skin models and calculation of skin dose coefficients for electron exposures

    NASA Astrophysics Data System (ADS)

    Yeom, Yeon Soo; Kim, Chan Hyeong; Nguyen, Thang Tat; Choi, Chansoo; Han, Min Cheol; Jeong, Jong Hwi

    2016-08-01

    The voxel-type reference phantoms of the International Commission on Radiological Protection (ICRP), due to their limited voxel resolutions, cannot represent the 50- μm-thick radiosensitive target layer of the skin necessary for skin dose calculations. Alternatively, in ICRP Publication 116, the dose coefficients (DCs) for the skin were calculated approximately, averaging absorbed dose over the entire skin depth of the ICRP phantoms. This approximation is valid for highly-penetrating radiations such as photons and neutrons, but not for weakly penetrating radiations like electrons due to the high gradient in the dose distribution in the skin. To address the limitation, the present study introduces skin polygon-mesh (PM) models, which have been produced by converting the skin models of the ICRP voxel phantoms to a high-quality PM format and adding a 50- μm-thick radiosensitive target layer into the skin models. Then, the constructed skin PM models were implemented in the Geant4 Monte Carlo code to calculate the skin DCs for external exposures of electrons. The calculated values were then compared with the skin DCs of the ICRP Publication 116. The results of the present study show that for high-energy electrons (≥ 1 MeV), the ICRP-116 skin DCs are, indeed, in good agreement with the skin DCs calculated in the present study. For low-energy electrons (< 1 MeV), however, significant discrepancies were observed, and the ICRP-116 skin DCs underestimated the skin dose as much as 15 times for some energies. Besides, regardless of the small tissue weighting factor of the skin ( w T = 0.01), the discrepancies in the skin dose were found to result in significant discrepancies in the effective dose, demonstarting that the effective DCs in ICRP-116 are not reliable for external exposure to electrons.

  12. ALL AGES LEAD MODEL

    EPA Science Inventory

    The Integrated Exposure Uptake Biokinetic (IEUBK) Model for Lead in Children (version 0.99d) was released in March 1994, and has been widely accepted in the risk assessment community as a tool for implementing the site specific risk assessment process when the issue is childhood...

  13. Capstone Depleted Uranium Aerosol Biokinetics, Concentrations, and Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilmette, Raymond A.; Miller, Guthrie; Parkhurst, MaryAnn

    2009-02-26

    One of the principal goals of the Capstone Depleted Uranium (DU) Aerosol Study was to quantify and characterize DU aerosols generated inside armored vehicles by perforation with a DU penetrator. This study consequently produced a database in which the DU aerosol source terms were specified both physically and chemically for a variety of penetrator-impact geometries and conditions. These source terms were used to calculate radiation doses and uranium concentrations for various scenarios as part of the Capstone DU Human Health Risk Assessment (HHRA). This paper describes the scenario-related biokinetics of uranium, and summarizes intakes, chemical concentrations to the organs, andmore » E(50) and HT(50) for organs and tissues based on exposure scenarios for personnel in vehicles at the time of perforation as well as for first responders. For a given exposure scenario (duration time and breathing rates), the range of DU intakes among the target vehicles and shots was not large, about a factor of 10, with the lowest being from a ventilated operational Abrams tank and the highest being for an unventilated Abrams with DU penetrator perforating DU armor. The ranges of committed effective doses were more scenario-dependent than were intakes. For example, the largest range, a factor of 20, was shown for scenario A, a 1-min exposure, whereas, the range was only a factor of two for the first-responder scenario (E). In general, the committed effective doses were found to be in the tens of mSv. The risks ascribed to these doses are discussed separately.« less

  14. Biokinetics and dosimetry of several radiolabelled peptides in cancer cells

    NASA Astrophysics Data System (ADS)

    Rodríguez-Cortés, J.; Ferro-Flores, G.; de Murphy, C. Arteaga; Pedraza-López, M.; Ramírez-Iglesias, M. A. T.

    Radiolabelled peptides have been used as target-specific radiopharmaceuticals. The goal of this research was the in vitro assessment of the uptake, internalization, externalization, and efflux of five radiolabelled peptides in cancer cells to estimate radiation-absorbed doses from experimental biokinetic data. 177Lu-DOTA-octreotate, 188Re-lanreotide, and 99mTc-HYNIC-octreotide were studied in the AR42J cell line. The PC3 and NCIH69 cells were used for 99mTc-HYNIC-bombesin and 177Lu-DOTA-minigastrin, respectively. The cumulated activities in the membrane and cytoplasm were calculated by integration of the experimental time-activity curves and used for dosimetry calculations according to the Medical Internal Radiation Dose (MIRD) cellular methodology. The mean absorbed dose to the cell nucleus were 0.69±0.09, 0.11±0.08, 0.55±0.09, 3.45±0.48, and 3.30±0.65 Gy/Bq for 99mTc-HYNIC-bombesin, 99mTc-HYNIC-octreotide, 177Lu-DOTA-minigastrin, 177Lu-DOTA-octreotate, and 188Re-lanreotide, respectively. If radiopharmaceutical cell kinetics were not used and only uptake data were considered, the calculated doses would be overestimated up to 25 times.

  15. An age dependent model for radium metabolism in man.

    PubMed

    Johnson, J R

    1983-01-01

    The model developed by a Task Group of Committee 2 of ICRP to describe Alkaline Earth Metabolism in Adult Man (ICRP Publication 20) has been modified so that recycling is handled explicitly, and retention in mineral bone is represented by second compartments rather than by the product of a power function and an exponential. This model has been extended to include all ages from birth to adult man, and has been coupled with modified "ICRP" lung and G.I. tract models so that activity in organs can be calculated as functions of time during or after exposures. These activities, and age dependent "specific effective energy" factors, are then used to calculate age dependent dose rates, and dose commitments. This presentation describes this work, with emphasis on the model parameters and results obtained for radium.

  16. Biokinetics of 13C in the human body after oral administration of 13C-labeled glucose as an index for the biokinetics of 14C.

    PubMed

    Masuda, Tsuyoshi; Tako, Yasuhiro; Matsushita, Kensaku; Takeda, Hiroshi; Endo, Masahiro; Nakamura, Yuji; Hisamatsu, Shun'ichi

    2016-09-01

    The retention of 13 C in the human body after oral administration of 13 C-labeled glucose was studied in three healthy volunteer subjects to estimate the 50 year cumulative body burden for 13 C as an index of the committed dose of the radioisotope 14 C. After administration of 13 C-labeled glucose, the volunteers ingested controlled diets with a fixed number of calories for 112 d. Samples of breath and urine were collected up to 112 d after administration. Samples of feces were collected up to 14 d after administration. Hair samples were obtained at 119 d after administration and analyzed as a representative index of the rate of excretion of organic 13 C via pathways such as skin cell exfoliation and mucus secretion. All samples were analyzed for 13 C/ 12 C atomic ratio to determine the rate of excretion via each pathway. We then constructed a metabolic model with a total of four pathways (breath, urine, feces, and other) comprising seven compartments. We determined the values of the biokinetic parameters in the model by using the obtained excretion data. From 74% to 94% of the 13 C administered was excreted in breath, whereas  <2% was excreted in urine and feces. In the other pathway, the excretion rate constant in the compartment with the longest residence time stretched to hundreds of days but the rate constant for each subject was not statistically significant (P value  >  0.1). In addition, the dataset for one of the three subjects was markedly different from those of the other two. When we estimated the 50 year cumulative body burden for 13 C by using our model and we included non-statistically significant parameters, a considerable cumulative body burden was found in the compartments excreting to the other pathway. Although our results on the cumulative body burden of 13 C from orally administered carbon as glucose were inconclusive, we found that the compartments excreting to the other pathway had a markedly long residence time and therefore

  17. Current risk estimates based on the A-bomb survivors data - a discussion in terms of the ICRP recommendations on the neutron weighting factor.

    PubMed

    Rühm, W; Walsh, L

    2007-01-01

    Currently, most analyses of the A-bomb survivors' solid tumour and leukaemia data are based on a constant neutron relative biological effectiveness (RBE) value of 10 that is applied to all survivors, independent of their distance to the hypocentre at the time of bombing. The results of these analyses are then used as a major basis for current risk estimates suggested by the International Commission on Radiological Protection (ICRP) for use in international safety guidelines. It is shown here that (i) a constant value of 10 is not consistent with weighting factors recommended by the ICRP for neutrons and (ii) it does not account for the hardening of the neutron spectra in Hiroshima and Nagasaki, which takes place with increasing distance from the hypocentres. The purpose of this paper is to present new RBE values for the neutrons, calculated as a function of distance from the hypocentres for both cities that are consistent with the ICRP60 neutron weighting factor. If based on neutron spectra from the DS86 dosimetry system, these calculations suggest values of about 31 at 1000 m and 23 at 2000 m ground range in Hiroshima, while the corresponding values for Nagasaki are 24 and 22. If the neutron weighting factor that is consistent with ICRP92 is used, the corresponding values are about 23 and 21 for Hiroshima and 21 and 20 for Nagasaki, respectively. It is concluded that the current risk estimates will be subject to some changes in view of the changed RBE values. This conclusion does not change significantly if the new doses from the Dosimetry System DS02 are used.

  18. A brief overview of compartmental modeling for intake of plutonium via wounds

    DOE PAGES

    Poudel, Deepesh; Klumpp, John Allan; Waters, Tom L.; ...

    2017-06-07

    Here, the aim of this study is to present several approaches that have been used to model the behavior of radioactive materials (specifically Pu) in contaminated wounds. We also review some attempts by the health physics community to validate and revise the National Council on Radiation Protection and Measurements (NCRP) 156 biokinetic model for wounds, and present some general recommendations based on the review. Modeling of intake via the wound pathway is complicated because of a large array of wound characteristics (e.g. solubility and chemistry of the material, type and depth of the tissue injury, anatomical location of injury). Moreover,more » because a majority of the documented wound cases in humans are medically treated (excised or treated with chelation), the data to develop biokinetic models for unperturbed wound exposures are limited. Since the NCRP wound model was largely developed from animal data, it is important to continue to validate and improve the model using human data whenever plausible.« less

  19. Identification of nevadensin as an important herb-based constituent inhibiting estragole bioactivation and physiology-based biokinetic modeling of its possible in vivo effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alhusainy, W., E-mail: wasma.alhusainy@wur.n; International Organization of Flavor Industries, IOFI, 1214 Vernier, Geneve; Nestle Research Centre, Nestec Ltd., Vers-Chez-Les-Blanc, Lausanne

    Estragole is a natural constituent of several herbs and spices including sweet basil. In rodent bioassays, estragole induces hepatomas, an effect ascribed to estragole bioactivation to 1'-sulfooxyestragole resulting in DNA adduct formation. The present paper identifies nevadensin as a basil constituent able to inhibit DNA adduct formation in rat hepatocytes exposed to the proximate carcinogen 1'-hydroxyestragole and nevadensin. This inhibition occurs at the level of sulfotransferase (SULT)-mediated bioactivation of 1'-hydroxyestragole. The Ki for SULT inhibition by nevadensin was 4 nM in male rat and human liver fractions. Furthermore, nevadensin up to 20 {mu}M did not inhibit 1'-hydroxyestragole detoxification by glucuronidationmore » and oxidation. The inhibition of SULT by nevadensin was incorporated into the recently developed physiologically based biokinetic (PBBK) rat and human models for estragole bioactivation and detoxification. The results predict that co-administration of estragole at a level inducing hepatic tumors in vivo (50 mg/kg bw) with nevadensin at a molar ratio of 0.06, representing the ratio of their occurrence in basil, results in almost 100% inhibition of the ultimate carcinogen 1'-sulfooxyestragole when assuming 100% uptake of nevadensin. Assuming 1% uptake, inhibition would still amount to more than 83%. Altogether these data point at a nevadensin-mediated inhibition of the formation of the ultimate carcinogenic metabolite of estragole, without reducing the capacity to detoxify 1'-hydroxyestragole via glucuronidation or oxidation. These data also point at a potential reduction of the cancer risk when estragole exposure occurs within a food matrix containing SULT inhibitors compared to what is observed upon exposure to pure estragole.« less

  20. Physiologically based pharmacokinetic modeling of (18)F-SiFAlin-Asp3-PEG1-TATE in AR42J tumor bearing mice.

    PubMed

    Maaß, Christian; Rivas, Jose Ricardo Avelar; Attarwala, Ali Asgar; Hardiansyah, Deni; Niedermoser, Sabrina; Litau, Shanna; Wängler, Carmen; Wängler, Björn; Glatting, Gerhard

    2016-04-01

    Peptide receptor radionuclide therapy (PRRT) is commonly performed in the treatment of neuroendocrine tumors (NET), where somatostatin analogs (DOTATATE) are radiolabeled with (90)Y, (68)Ga or (111)In for pre-therapeutic and therapeutic purposes. Quantitative evaluation of the biokinetic data can be performed by using physiologically based pharmacokinetic (PBPK) models. Knowledge about the biodistribution in a pre-clinical setting would allow optimizing the translation from bench to bedside. The aim of this study was to develop a PBPK model to describe the biodistribution of a novel sst2-targeting radiotracer. Biokinetic data of six mice after injection of (18)F-SiFAlin-Asp3-PEG1-TATE were investigated using two PBPK models. The PBPK models describe the biodistribution of the tracer in the tumor, kidneys, liver, remainder and whole body via blood flow to these organs via absorption, distribution, metabolism and excretion. A recently published sst2 PBPK model for humans (model 1) was used to describe the data. Physiological information in this model was adapted to that of a mouse. Model 1 was further modified by implementing receptor-mediated endocytosis (model 2). Model parameters were fitted to the biokinetic data of each mouse. Model selection was performed by calculating Akaike weights wi using the corrected Akaike Information Criterion (AICc). The implementation of receptor-mediated endocytosis considerably improved the description of the biodistribution (Akaike weights w1=0% and w2=100% for model 1 and 2, respectively). The resulting time-integrated activity coefficients determined by model 2 were for tumor (0.05 ± 0.02) h, kidneys (0.11 ± 0.01) h and liver (0.02 ± 0.01) h. Simply downscaling a human PBPK model does not allow for an accurate description of (18)F-SiFAlin-Asp3-PEG1-TATE in mice. Biokinetics of this tracer can be accurately and adequately described using a physiologically based pharmacokinetic model including receptor-mediated endocytosis

  1. The STATFLUX code: a statistical method for calculation of flow and set of parameters, based on the Multiple-Compartment Biokinetical Model

    NASA Astrophysics Data System (ADS)

    Garcia, F.; Mesa, J.; Arruda-Neto, J. D. T.; Helene, O.; Vanin, V.; Milian, F.; Deppman, A.; Rodrigues, T. E.; Rodriguez, O.

    2007-03-01

    radioactive substances, through environmental pathways, is very important for radiological protection of populations. One such pathway, associated with the food chain, is the grass-animal-man sequence. The distribution of trace elements in humans and laboratory animals has been intensively studied over the past 60 years [R.C. Pendlenton, C.W. Mays, R.D. Lloyd, A.L. Brooks, Differential accumulation of iodine-131 from local fallout in people and milk, Health Phys. 9 (1963) 1253-1262]. In addition, investigations on the incidence of cancer in humans, and a possible causal relationship to radioactive fallout, have been undertaken [E.S. Weiss, M.L. Rallison, W.T. London, W.T. Carlyle Thompson, Thyroid nodularity in southwestern Utah school children exposed to fallout radiation, Amer. J. Public Health 61 (1971) 241-249; M.L. Rallison, B.M. Dobyns, F.R. Keating, J.E. Rall, F.H. Tyler, Thyroid diseases in children, Amer. J. Med. 56 (1974) 457-463; J.L. Lyon, M.R. Klauber, J.W. Gardner, K.S. Udall, Childhood leukemia associated with fallout from nuclear testing, N. Engl. J. Med. 300 (1979) 397-402]. From the pathways of entry of radionuclides in the human (or animal) body, ingestion is the most important because it is closely related to life-long alimentary (or dietary) habits. Those radionuclides which are able to enter the living cells by either metabolic or other processes give rise to localized doses which can be very high. The evaluation of these internally localized doses is of paramount importance for the assessment of radiobiological risks and radiological protection. The time behavior of trace concentration in organs is the principal input for prediction of internal doses after acute or chronic exposure. The General Multiple-Compartment Model (GMCM) is the powerful and more accepted method for biokinetical studies, which allows the calculation of concentration of trace elements in organs as a function of time, when the flow parameters of the model are known. However, few

  2. Human semen refrigeration at + 4 degrees C: bio-kinetic characteristics.

    PubMed

    Dondero, Franco; Rossi, Tiziana; Delfino, Michele; Imbrogno, Norina; Cannistrà, Stefania; Mazzilli, Fernando

    2006-01-01

    The aim of our study was to evaluate the bio-kinetic characteristics of human semen refrigerated for different periods and to compare the effects of refrigeration at +4 degrees C against cryopreservation of human sperm at -196 degrees C. Semen was obtained from 30 male partners of infertile couples (infertile subjects) with the following semen profile: sperm count >or=10 x 10(6)/ml; progressive motility >or=20%; atypical forms <70% and white blood cells <1.0 x 10(6)/ml. Fifteen normospermic subjects were also selected as controls (control subjects). The following tests were carried out on basal, refrigerated and cryopreserved sperm: a) sperm kinetic properties (by Superimposed Image Analysis System); b) the Hypoosmotic Viability Test (HVT) (combined Hypoosmotic Swelling and Viability Test). The results of the study showed that the percentage recovery of kinetic properties and of HVT were optimum for up to 48 h. After refrigeration for 72 h, a drastic decrease in straight motility recovery was observed. No significant differences were observed between cryopreservation and refrigeration at +4 degrees C for 48 h for motility or HVT recoveries in samples from control subjects. However, in infertile subjects, a significant decrease in straight progressive motility and HVT recoveries was observed in cryopreserved samples compared to those refrigerated for 48 h. Neither refrigeration nor cryopreservation led to the growth of pathogenic bacteria in any of the cases studied. Based on the above results, refrigeration could represent a useful alternative to the cryopreservation method.

  3. Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations

    PubMed Central

    Thilander-Klang, Anne; Ylhan, Betȕl; Lofthag-Hansen, Sara; Ekestubbe, Annika

    2016-01-01

    Objective: During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Methods: Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. Results: The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a full-mouth intraoral examination was 15 μSv and for panoramic radiography, the effective dose was in the range of 19–75 μSv, depending on the panoramic equipment used. Conclusion: The effective dose from a full-mouth intraoral examination is lower and that from panoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk–benefit profile of this technique must be assessed for the individual patient. Advances in knowledge: The effective dose of radiation from panoramic radiography is higher than previously reported and there is large variability in the delivered radiation dosage among the different types of equipment used. PMID:27452261

  4. Fetal and maternal dose assessment for diagnostic scans during pregnancy

    NASA Astrophysics Data System (ADS)

    Rafat Motavalli, Laleh; Miri Hakimabad, Hashem; Hoseinian Azghadi, Elie

    2016-05-01

    Despite the concerns about prenatal exposure to ionizing radiation, the number of nuclear medicine examinations performed for pregnant women increased in the past decade. This study attempts to better quantify radiation doses due to diagnostic nuclear medicine procedures during pregnancy with the help of our recently developed 3, 6, and 9 month pregnant hybrid phantoms. The reference pregnant models represent the adult female international commission on radiological protection (ICRP) reference phantom as a base template with a fetus in her gravid uterus. Six diagnostic scintigraphy scans using different radiopharmaceuticals were selected as typical diagnostic nuclear medicine procedures. Furthermore, the biokinetic data of radioiodine was updated in this study. A compartment representing iodide in fetal thyroid was addressed explicitly in the biokinetic model. Calculations were performed using the Monte Carlo transport method. Tabulated dose coefficients for both maternal and fetal organs are provided. The comparison was made with the previously published fetal doses calculated for stylized pregnant female phantoms. In general, the fetal dose in previous studies suffers from an underestimation of up to 100% compared to fetal dose at organ level in this study. A maximum of difference in dose was observed for the fetal thyroid compared to the previous studies, in which the traditional models did not contain the fetal thyroid. Cumulated activities of major source organs are primarily responsible for the discrepancies in the organ doses. The differences in fetal dose depend on several other factors including chord length distribution between fetal organs and maternal major source organs, and anatomical differences according to gestation periods. Finally, considering the results of this study, which was based on the realistic pregnant female phantoms, a more informed evaluation of the risks and benefits of the different procedures could be made.

  5. Developing a physiologically based approach for modeling plutonium decorporation therapy with DTPA.

    PubMed

    Kastl, Manuel; Giussani, Augusto; Blanchardon, Eric; Breustedt, Bastian; Fritsch, Paul; Hoeschen, Christoph; Lopez, Maria Antonia

    2014-11-01

    To develop a physiologically based compartmental approach for modeling plutonium decorporation therapy with the chelating agent Diethylenetriaminepentaacetic acid (Ca-DTPA/Zn-DTPA). Model calculations were performed using the software package SAAM II (©The Epsilon Group, Charlottesville, Virginia, USA). The Luciani/Polig compartmental model with age-dependent description of the bone recycling processes was used for the biokinetics of plutonium. The Luciani/Polig model was slightly modified in order to account for the speciation of plutonium in blood and for the different affinities for DTPA of the present chemical species. The introduction of two separate blood compartments, describing low-molecular-weight complexes of plutonium (Pu-LW) and transferrin-bound plutonium (Pu-Tf), respectively, and one additional compartment describing plutonium in the interstitial fluids was performed successfully. The next step of the work is the modeling of the chelation process, coupling the physiologically modified structure with the biokinetic model for DTPA. RESULTS of animal studies performed under controlled conditions will enable to better understand the principles of the involved mechanisms.

  6. Radionuclide decorporation: matching the biokinetics of actinides by transdermal delivery of pro-chelators.

    PubMed

    Zhang, Yong; Sadgrove, Matthew P; Mumper, Russell J; Jay, Michael

    2013-10-01

    The threat of nuclear terrorism by the deliberate detonation of a nuclear weapon or radiological dispersion device ("dirty bomb") has made emergency response planning a priority. The only FDA-approved treatments for contamination with isotopes of the transuranic elements Am, Pu, and Cm are the Ca and Zn salts of diethylenetriaminepentaacetic acid (DTPA). These injectable products are not well suited for use in a mass contamination scenario as they require skilled professionals for their administration and are rapidly cleared from the circulation. To overcome the mismatch in the pharmacokinetics of the DTPA and the biokinetics of these transuranic elements, which are slowly released from contamination sites, the penta-ethyl ester of DTPA (C2E5) was prepared and formulated in a nonaqueous gel for transdermal administration. When gels comprised of 40% C2E5, 40-45% Miglyol® 840, and 15-20% ethyl cellulose were spiked with [(14)C]-C2E5 and applied to rat skin; over 60% of the applied dose was absorbed within a 24-h period. Radioactivity was observed in urinary and fecal excretions for over 3 days after removal of the gel. Using an (241)Am wound contamination model, transdermal C2E5 gels were able to enhance total body elimination and reduce the liver and skeletal burden of (241)Am in a dose-dependent manner. The efficacy achieved by a single 1,000 mg/kg dose to contaminated rats was statistically comparable to intravenous Ca-DTPA at 14 mg/kg. The effectiveness of this treatment, favorable sustained release profile of pro-chelators, and ease of administration support its use following radiological emergencies and for its inclusion in the Strategic National Stockpile.

  7. Identification of Biokinetic Models Using the Concept of Extents.

    PubMed

    Mašić, Alma; Srinivasan, Sriniketh; Billeter, Julien; Bonvin, Dominique; Villez, Kris

    2017-07-05

    The development of a wide array of process technologies to enable the shift from conventional biological wastewater treatment processes to resource recovery systems is matched by an increasing demand for predictive capabilities. Mathematical models are excellent tools to meet this demand. However, obtaining reliable and fit-for-purpose models remains a cumbersome task due to the inherent complexity of biological wastewater treatment processes. In this work, we present a first study in the context of environmental biotechnology that adopts and explores the use of extents as a way to simplify and streamline the dynamic process modeling task. In addition, the extent-based modeling strategy is enhanced by optimal accounting for nonlinear algebraic equilibria and nonlinear measurement equations. Finally, a thorough discussion of our results explains the benefits of extent-based modeling and its potential to turn environmental process modeling into a highly automated task.

  8. Analysis of urinary excretion data from three plutonium-contaminated wounds at Los Alamos National Laboratory

    DOE PAGES

    Poudel, Deepesh; Klumpp, John A.; Waters, Tom L.; ...

    2017-07-14

    The NCRP-156 Report proposes seven different biokinetic models for the wound cases depending on the physicochemistry of the contaminant. Because the models were heavily based on experimental animal data, the authors of the report encouraged application and validation of the models using bioassay data from actual human exposures. Each of the wound models was applied to three plutonium-contaminated wounds, and the models resulted in a good agreement to only one of the cases. We then applied a simpler biokinetic model structure to the bioassay data and showed that fitting the transfer rates from this model structure yielded better agreement withmore » the data than does the best-fitting NCRP-156 model. Because the biokinetics of radioactive material in each wound is different, it is impractical to propose a discrete set of model parameters to describe the biokinetics of radionuclides in all wounds, and thus each wound should be treated empirically.« less

  9. 99mTc-labeled PSMA inhibitor: Biokinetics and radiation dosimetry in healthy subjects and imaging of prostate cancer tumors in patients.

    PubMed

    Santos-Cuevas, Clara; Davanzo, Jenny; Ferro-Flores, Guillermina; García-Pérez, Francisco O; Ocampo-García, Blanca; Ignacio-Alvarez, Eleazar; Gómez-Argumosa, Edgar; Pedraza-López, Martha

    2017-09-01

    The prostate-specific membrane antigen (PSMA) is expressed in epithelial cells of the prostate and highly overexpressed in 95% of advanced prostate cancers. The aims of this study was to estimate the biokinetics and dosimetry of 99m Tc-EDDA/HYNIC-iPSMA ( 99m Tc-labeled PSMA inhibitor) in eight healthy subjects and evaluate its usefulness as a tumor-imaging agent in eight prostate cancer patients. 99m Tc-EDDA/HYNIC-iPSMA was obtained from a lyophilized formulation with radiochemical purities >98%, determined by reversed-phase HPLC and ITLC-SG analyses. Whole-body images from eight healthy subjects were acquired at 20min, and at 2, 6 and 24h after 99m Tc-EDDA/HYNIC-iPSMA administration. Regions of interest (ROIs) were drawn around the source organs on each time frame. Each ROI was corrected by background, attenuation, scattered radiation and physical decay. The image sequence was used to extrapolate the 99m Tc-EDDA/HYNIC-iPSMA time-activity curves of each organ to adjust the biokinetic model and calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation doses. In eight prostate cancer patients with histologically confirmed cancer, whole-body SPECT/CT images were obtained at 3h. The blood activity showed a half-life value of 4.98min for the fast component (T 1/2 α=ln2/8.34), 2.49h for the first slow component (T 1/2 β=ln2/0.278), and 9.24h for the second slow component (T 1/2 γ=ln2/0.076). Images from patients showed an average tumor/background ratio of 8.99±3.27 at 3h. The average equivalent doses calculated for a study using 740MBq were 3.80, 7.06, 9.69, 10.70, and 28.80mSv for the breast, spleen, salivary glands, liver, and kidneys respectively, with an effective dose of 3.42±0.78mSv. All the absorbed doses were comparable to those known for most of the 99m Tc studies. 99m Tc-EDDA/HYNIC-iPSMA obtained from kit formulations showed high tumor uptake in

  10. MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolch, Wesley

    The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2’s Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2’s revision of the target tissues of relevance for radiogenicmore » bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-μm cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-μm layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public« less

  11. Peer Review of Report Modeling the Relationship Between Lead in Drinking Water and Blood Lead Levels in Children

    EPA Science Inventory

    EPA is peer reviewing the Agency’s report modeling the relationship between lead in drinking water and blood lead levels in children utilizing the Integrated Exposure Uptake Biokinetic (IEUBK) model. The report being peer reviewed may be used to inform the derivation of a concent...

  12. The Interpretation of Mg/Ca in Ostracode Valves: Biokinetic vs. Thermodynamic Controls

    NASA Astrophysics Data System (ADS)

    Dettman, D. L.; Palacios-Fest, M. R.; Cohen, A. S.

    2004-12-01

    calcification approaches magnesite; other crustaceans accumulate Mg prior to molting. Finally, we note that ostracode valves typically fall into the 0.003 to 0.04 range of molar Mg/Ca ratios, and that ratios greater than 0.05 are extremely rare in the valves of fully-calcified adult ostracodes of any species. Yet these animals thrive in waters where the range of Mg/Ca ratio covers more than 3 orders of magnitude. A distribution coefficient model incorrectly predicts a similar 3 order of magnitude range in shell chemistry. Alternatively a bio-kinetic model for valve chemistry yields very promising results for the use of Mg/Ca ratios in ostracode valves as a paleothermometer.

  13. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    NASA Astrophysics Data System (ADS)

    Schlattl, H.; Zankl, M.; Petoussi-Henss, N.

    2007-04-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

  14. BK/TD models for analyzing in vitro impedance data on cytotoxicity.

    PubMed

    Teng, S; Barcellini-Couget, S; Beaudouin, R; Brochot, C; Desousa, G; Rahmani, R; Pery, A R R

    2015-06-01

    The ban of animal testing has enhanced the development of new in vitro technologies for cosmetics safety assessment. Impedance metrics is one such technology which enables monitoring of cell viability in real time. However, analyzing real time data requires moving from static to dynamic toxicity assessment. In the present study, we built mechanistic biokinetic/toxicodynamic (BK/TD) models to analyze the time course of cell viability in cytotoxicity assay using impedance. These models account for the fate of the tested compounds during the assay. BK/TD models were applied to analyze HepaRG cell viability, after single (48 h) and repeated (4 weeks) exposures to three hepatotoxic compounds (coumarin, isoeugenol and benzophenone-2). The BK/TD models properly fit the data used for their calibration that was obtained for single or repeated exposure. Only for one out of the three compounds, the models calibrated with a single exposure were able to predict repeated exposure data. We therefore recommend the use of long-term exposure in vitro data in order to adequately account for chronic hepatotoxic effects. The models we propose here are capable of being coupled with human biokinetic models in order to relate dose exposure and human hepatotoxicity. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  15. Human biodistribution and radiation dosimetry of 82Rb.

    PubMed

    Senthamizhchelvan, Srinivasan; Bravo, Paco E; Esaias, Caroline; Lodge, Martin A; Merrill, Jennifer; Hobbs, Robert F; Sgouros, George; Bengel, Frank M

    2010-10-01

    Prior estimates of radiation-absorbed doses from (82)Rb, a frequently used PET perfusion tracer, yielded discrepant results. We reevaluated (82)Rb dosimetry using human in vivo biokinetic measurements. Ten healthy volunteers underwent dynamic PET/CT (6 contiguous table positions, each with separate (82)Rb infusion). Source organ volumes of interest were delineated on the CT images and transferred to the PET images to obtain time-integrated activity coefficients. Radiation doses were estimated using OLINDA/EXM 1.0. The highest mean absorbed organ doses (μGy/MBq) were observed for the kidneys (5.81), heart wall (3.86), and lungs (2.96). Mean effective doses were 1.11 ± 0.22 and 1.26 ± 0.20 μSv/MBq using the tissue-weighting factors of the International Commission on Radiological Protection (ICRP), publications 60 and 103, respectively. Our current (82)Rb dosimetry suggests reasonably low radiation exposure. On the basis of this study, a clinical (82)Rb injection of 2 × 1,480 MBq (80 mCi) would result in a mean effective dose of 3.7 mSv using the weighting factors of the ICRP 103-only slightly above the average annual natural background exposure in the United States (3.1 mSv).

  16. Dosimetric models of the eye and lens of the eye and their use in assessing dose coefficients for ocular exposures.

    PubMed

    Bolch, W E; Dietze, G; Petoussi-Henss, N; Zankl, M

    2015-06-01

    Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms.

    PubMed

    Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee

    2016-04-01

    The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1mSv y(-1) for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Energy use and carbon footprints differ dramatically for diverse wastewater-derived carbonaceous substrates: An integrated exploration of biokinetics and life-cycle assessment.

    PubMed

    Li, Yanbo; Wang, Xu; Butler, David; Liu, Junxin; Qu, Jiuhui

    2017-03-21

    Energy neutrality and reduction of carbon emissions are significant challenges to the enhanced sustainability of wastewater treatment plants (WWTPs). Harvesting energy from wastewater carbonaceous substrates can offset energy demands and enable net power generation; yet, there is limited research about how carbonaceous substrates influence energy and carbon implications of WWTPs with integrated energy recovery at systems-level. Consequently, this research uses biokinetics modelling and life cycle assessment philology to explore this notion, by tracing and assessing the quantitative flows of energy embodied or captured, and by exploring the carbon footprint throughout an energy-intensive activated sludge process with integrated energy recovery facilities. The results indicate that energy use and carbon footprint per cubic meter of wastewater treated, varies markedly with the carbon substrate. Compared with systems driven with proteins, carbohydrates or other short-chain fatty acids, systems fed with acetic acid realized energy neutrality with maximal net gain of power from methane combustion (0.198 kWh) and incineration of residual biosolids (0.153 kWh); and also achieved a negative carbon footprint (72.6 g CO 2 ). The findings from this work help us to better understand and develop new technical schemes for improving the energy efficiency of WWTPs by repurposing the stream of carbon substrates across systems.

  19. Childhood lead biokinetics and associations with age among a group of lead-poisoned children in China.

    PubMed

    Specht, Aaron J; Weisskopf, Marc; Nie, Linda H

    2018-04-30

    Childhood lead exposure has been shown to have a significant effect on neurodevelopment. Many of the biokinetics involved with lead biomarkers in children still remain unknown. Two hundred fifty (157 in the exposed group and 93 controls) children were enrolled in our study and lead exposed children returned for multiple visits for measurement of blood and bone lead and chelation treatment. We demonstrated that the correlation between blood and bone lead increased with subsequent visits. We calculated the blood lead half-life for 50 patients, and found a significant (p-value < 0.001) positive correlation with age. For ages 1-3 years (N = 17), the blood lead half-life was found to be 6.9 ± 4.0 days and for 3+ years it was found to be (N = 33) 19.3 ± 14.1 days. In conclusion, the turnover of lead in children is faster than in adults. Our results indicate that blood lead is a more acute biomarker of exposure than previously thought, which will impact studies of children's health using blood lead as a biomarker.

  20. Fluence-to-dose conversion coefficients for heavy ions calculated using the PHITS code and the ICRP/ICRU adult reference computational phantoms.

    PubMed

    Sato, Tatsuhiko; Endo, Akira; Niita, Koji

    2010-04-21

    The fluence to organ-absorbed-dose and effective-dose conversion coefficients for heavy ions with atomic numbers up to 28 and energies from 1 MeV/nucleon to 100 GeV/nucleon were calculated using the PHITS code coupled to the ICRP/ICRU adult reference computational phantoms, following the instruction given in ICRP Publication 103 (2007 (Oxford: Pergamon)). The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. The calculation results indicate that the effective dose can generally give a conservative estimation of the effective dose equivalent for heavy-ion exposure, although it is occasionally too conservative especially for high-energy lighter-ion irradiations. It is also found from the calculation that the conversion coefficients for the Q(y)-based effective dose equivalents are generally smaller than the corresponding Q(L)-based values because of the conceptual difference between LET and y as well as the numerical incompatibility between the Q(L) and Q(y) relationships. The calculated data of these dose conversion coefficients are very useful for the dose estimation of astronauts due to cosmic-ray exposure.

  1. Overview of ICRP Committee 3: protection in medicine.

    PubMed

    Vañó, E; Miller, D L; Rehani, M M

    2016-06-01

    Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other

  2. Mixing characterisation of full-scale membrane bioreactors: CFD modelling with experimental validation.

    PubMed

    Brannock, M; Wang, Y; Leslie, G

    2010-05-01

    Membrane Bioreactors (MBRs) have been successfully used in aerobic biological wastewater treatment to solve the perennial problem of effective solids-liquid separation. The optimisation of MBRs requires knowledge of the membrane fouling, biokinetics and mixing. However, research has mainly concentrated on the fouling and biokinetics (Ng and Kim, 2007). Current methods of design for a desired flow regime within MBRs are largely based on assumptions (e.g. complete mixing of tanks) and empirical techniques (e.g. specific mixing energy). However, it is difficult to predict how sludge rheology and vessel design in full-scale installations affects hydrodynamics, hence overall performance. Computational Fluid Dynamics (CFD) provides a method for prediction of how vessel features and mixing energy usage affect the hydrodynamics. In this study, a CFD model was developed which accounts for aeration, sludge rheology and geometry (i.e. bioreactor and membrane module). This MBR CFD model was then applied to two full-scale MBRs and was successfully validated against experimental results. The effect of sludge settling and rheology was found to have a minimal impact on the bulk mixing (i.e. the residence time distribution).

  3. Report of Task Group on the implications of the implementation of the ICRP recommendations for a revised dose limit to the lens of the eye.

    PubMed

    Broughton, J; Cantone, M C; Ginjaume, M; Shah, B

    2013-12-01

    This report was commissioned by the IRPA President to provide an assessment of the impact on members of IRPA Associate Societies of the introduction of ICRP recommendations for a reduced dose limit for the lens of the eye. The report summarises current practice and considers possible changes that may be required. Recommendations for further collaboration, clarification and changes to working practices are suggested.

  4. Overview of ICRP Committee 5: protection of the environment.

    PubMed

    Larsson, C-M

    2016-06-01

    Protection of the environment is integral to the system of radiological protection, as outlined in the 2007 Recommendations of the International Commission on Radiological Protection (ICRP, Publication 103). The Commission's activities in this area are mainly pursued by Committee 5 and its associated Task Groups. Publication 91 broadly outlines the approach to radiological protection of the environment, and its alignment with approaches to environmental protection from hazardous substances in general. Publications 108 and 114 provide the cornerstones of the environmental protection system and relevant databases. Publication 124 considers its application in planned, existing, and emergency exposure situations. The system centres on 12 Reference Animals and Plants (RAPs) with broad relevance for environmental protection based on their ubiquity and significance as well as other criteria, as described in Publication 108 The databases comprise general biology of the RAPs, transfer parameters, dose conversion coefficients, and effects data. Derived Consideration Reference Levels (DCRLs) were established for each RAP; a DCRL represents a band of dose rates that might result in some deleterious effects in individuals of that type of RAP. Newly established Task Group 99 will compile the RAP-specific reference information into monographs, with the view of updating information and improving the applicability of the system in different exposure situations. For certain scenarios, more precise and ecosystem-specific protection benchmarks may be justified, which would have to be informed by consideration of representative organisms (i.e. representative of a particular ecosystem and relevant to the specific scenario; Publication 124). Committee 5 will explore this further, making use of a limited number of case studies. © The International Society for Prosthetics and Orthotics.

  5. Regulation of biokinetics of (65)Zn by curcumin and zinc in experimentally induced colon carcinogenesis in rats.

    PubMed

    Jain, Kinnri; Dhawan, Devinder K

    2014-10-01

    This study was conducted to investigate the role of curcumin and zinc on the biokinetics and biodistribution of (65)Zn during colon carcinogenesis. Male wistar rats were divided into five groups, namely normal control, 1,2-dimethylhydrazine (DMH) treated, DMH + curcumin treated, DMH + zinc treated, and DMH + curcumin + zinc treated. Weekly subcutaneous injections of DMH (30 mg/kg body weight) for 16 weeks initiated colon carcinogenesis. Curcumin (100 mg/kg body weight orally) and ZnSO4 (227 mg/L in drinking water) were supplemented for 16 weeks. This study revealed a significant depression in the fast (Tb1) and slow component (Tb2) of biological half-life of (65)Zn in the whole body of DMH-treated rats, whereas liver showed a significant elevation in these components. Further, DMH treatment showed a significant increase in the uptake values of (65)Zn in colon, small intestine, and kidneys. Subcellular distribution depicted a significant increase in (65)Zn uptake values in mitochondrial, microsomal, and postmicrosomal fractions of colon. However, curcumin and zinc supplementation when given separately or in combination reversed the trends and restored the uptake values close to normal range. Our study concludes that curcumin and zinc supplementation during colon carcinogenesis shall prove to be efficacious in regulating the altered zinc metabolism.

  6. Comparison of the mean quality factors for astronauts calculated using the Q-functions proposed by ICRP, ICRU, and NASA

    NASA Astrophysics Data System (ADS)

    Sato, T.; Endo, A.; Niita, K.

    2013-07-01

    For the estimation of the radiation risk for astronauts, not only the organ absorbed doses but also their mean quality factors must be evaluated. Three functions have been proposed by different organizations for expressing the radiation quality, including the Q(L), Q(y), and QNASA(Z, E) relationships as defined in International Committee of Radiological Protection (ICRP) Publication 60, International Commission on Radiation Units and Measurements (ICRU) Report 40, and National Aeronautics and Space Administration (NASA) TP-2011-216155, respectively. The Q(L) relationship is the most simple and widely used for space dosimetry, but the use of the latter two functions enables consideration of the difference in the track structure of various charged particles during the risk estimation. Therefore, we calculated the mean quality factors in organs and tissues in ICRP/ICRU reference voxel phantoms for the isotropic exposure to various mono-energetic particles using the three Q-functions. The Particle and Heavy Ion Transport code System PHITS was employed to simulate the particle motions inside the phantoms. The effective dose equivalents and the phantom-averaged effective quality factors for the astronauts were then estimated from the calculated mean quality factors multiplied by the fluence-to-dose conversion coefficients and cosmic-ray fluxes inside a spacecraft. It was found from the calculations that QNASA generally gives the largest values for the phantom-averaged effective quality factors among the three Q-functions for neutron, proton, and lighter-ion irradiation, whereas Q(L) provides the largest values for heavier-ion irradiation. Overall, the introduction of QNASA instead of Q(L) or Q(y) in astronaut dosimetry results in the increase the effective dose equivalents because the majority of the doses are composed of the contributions from protons and neutrons, although this tendency may change by the calculation conditions.

  7. Evaluation of Pharmacokinetic Models for the Disposition of Lead (Pb) in Humans, in Support of Application to Occupational Exposure Limit Derivation

    DTIC Science & Technology

    2015-11-09

    as biokinetic or physiologically-based pharmacokinetic (PBPK) models, can readily incorporate multiple routes of exposure (e.g., baseline dietary ...1998) and in the code provided as a supplement to O’Flaherty (2000), as noted above. An aspect of the O’Flaherty model that contrasts to the... dietary Pb; a stable Pb isotope was substituted for some of the dietary Pb for limited periods. Tracer Pb concentrations were measured in blood

  8. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies.

    PubMed

    Farkas, Árpád; Balásházy, Imre

    2015-04-01

    A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams

    NASA Astrophysics Data System (ADS)

    Zhang, Juying; Hum Na, Yong; Caracappa, Peter F.; Xu, X. George

    2009-10-01

    This paper describes the development of a pair of adult male and adult female computational phantoms that are compatible with anatomical parameters for the 50th percentile population as specified by the International Commission on Radiological Protection (ICRP). The phantoms were designed entirely using polygonal mesh surfaces—a Boundary REPresentation (BREP) geometry that affords the ability to efficiently deform the shape and size of individual organs, as well as the body posture. A set of surface mesh models, from Anatomium™ 3D P1 V2.0, including 140 organs (out of 500 available) was adopted to supply the basic anatomical representation at the organ level. The organ masses were carefully adjusted to agree within 0.5% relative error with the reference values provided in the ICRP Publication 89. The finalized phantoms have been designated the RPI adult male (RPI-AM) and adult female (RPI-AF) phantoms. For the purposes of organ dose calculations using the MCNPX Monte Carlo code, these phantoms were subsequently converted to voxel formats. Monoenergetic photons between 10 keV and 10 MeV in six standard external photon source geometries were considered in this study: four parallel beams (anterior-posterior, posterior-anterior, left lateral and right lateral), one rotational and one isotropic. The results are tabulated as fluence-to-organ-absorbed-dose conversion coefficients and fluence-to-effective-dose conversion coefficients and compared against those derived from the ICRP computational phantoms, REX and REGINA. A general agreement was found for the effective dose from these two sets of phantoms for photon energies greater than about 300 keV. However, for low-energy photons and certain individual organs, the absorbed doses exhibit profound differences due to specific anatomical features. For example, the position of the arms affects the dose to the lung by more than 20% below 300 keV in the lateral source directions, and the vertical position of the testes

  10. Transfer parameters for ICRP's Reference Animals and Plants in a terrestrial Mediterranean ecosystem.

    PubMed

    Guillén, J; Beresford, N A; Baeza, A; Izquierdo, M; Wood, M D; Salas, A; Muñoz-Serrano, A; Corrales-Vázquez, J M; Muñoz-Muñoz, J G

    2018-06-01

    A system for the radiological protection of the environment (or wildlife) based on Reference Animals and Plants (RAPs) has been suggested by the International Commission on Radiological Protection (ICRP). To assess whole-body activity concentrations for RAPs and the resultant internal dose rates, transfer parameters are required. However, transfer values specifically for the taxonomic families defined for the RAPs are often sparse and furthermore can be extremely site dependent. There is also a considerable geographical bias within available transfer data, with few data for Mediterranean ecosystems. In the present work, stable element concentrations (I, Li, Be, B, Na, Mg, Al, P, S, K. Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Mo, Ag, Cd, Cs, Ba, Tl, Pb and U) in terrestrial RAPs, and the corresponding whole-body concentration ratios, CR wo , were determined in two different Mediterranean ecosystems: a Pinewood and a Dehesa (grassland with disperse tree cover). The RAPs considered in the Pinewood ecosystem were Pine Tree and Wild Grass; whereas in the Dehesa ecosystem those considered were Deer, Rat, Earthworm, Bee, Frog, Duck and Wild Grass. The CR wo values estimated from these data are compared to those reported in international compilations and databases. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Prediction of iodine-131 biokinetics and radiation doses from therapy on the basis of tracer studies: an important question for therapy planning in nuclear medicine.

    PubMed

    Willegaignon, José; Pelissoni, Rogério A; Lima, Beatriz C G D; Sapienza, Marcelo T; Coura-Filho, George B; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from

  12. A kinematic model to estimate the effective dose of radioactive isotopes in the human body for radiological protection

    NASA Astrophysics Data System (ADS)

    Sasaki, S.; Yamada, T.

    2013-12-01

    The great earthquake attacked the north-east area in Japan in March 11, 2011. The system of electrical facilities to control Fukushima Daiichi nuclear power station was completely destroyed by the following tsunamis. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and been diffused in the vicinity of this station. Radiological internal exposure becomes a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplified the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed an exact model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that the above method accord too much with the actual mechanism of metabolism in human bodies, it becomes rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional hydrological tank model. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of this method is to estimate the energy radiated from the radioactive nuclear disintegration of an atom by using classical theory of E. Fermi of beta decay and special relativity for various kinds of radioactive atoms. The parameters used in this study are only physical half-time and biological half-time, and there are no intentional and operational parameters of coefficients to adjust our theoretical runoff to observation of ICRP. Figure.1 compares time

  13. Particle deposition and clearance of atmospheric particles in the human respiratory tract during LACE 98

    NASA Astrophysics Data System (ADS)

    Bundke, U.; Hänel, G.

    2003-04-01

    During the LACE 98footnote{Lindenberg Aerosol Characterization Experiment, (Germany) 1998} experiment microphysical, chemical and optical properties of atmospheric particles were measured by several groups. (Bundke et al.). The particle deposition and clearance of the particles in the human respiratory tract was calculated using the ICRP (International Commission on Radiological Protection) deposition and clearance model (ICRP 1994). Particle growth as function of relative humidity outside the body was calculated from measurement data using the model introduced by Bundke et al.. Particle growth inside the body was added using a non-equilibrium particle growth model. As a result of the calculations, time series of the total dry particle mass and -size distribution were obtained for all compartments of the human respiratory tract defined by ICRP 1994. The combined ICRP deposition and clearance model was initialized for different probationers like man, woman, children of different ages and several circumstances like light work, sitting, sleeping etc. Keeping the conditions observed during LACE 98 constant a approximation of the aerosol burdens of the different compartments was calculated up to 4 years of exposure and compared to the results from Snipes et al. for the "Phoenix" and "Philadelphia" aerosol. References: footnotesize{ Bundke, U. et al.,it{Aerosol Optical Properties during the Lindenberg Aerosol Characterization Experiment (LACE 98)} ,10.1029/2000JD000188, JGR, 2002 ICRP,it{Human Respiratory Tract Model for Radiological Protection, Bd. ICRP Publication 66}, Annals of the ICRP, 24,1-3, Elsevier Science, Ocford, 1994 Snipes et al. ,it{The 1994 ICRP66 Human Respiratory Tract Model as a Tool for predicting Lung Burdens from Exposure to Environmental Aerosols}, Appl. Occup. Environ. Hyg., 12, 547-553,1997}

  14. Resonance behaviour of whole-body averaged specific energy absorption rate (SAR) in the female voxel model, NAOMI

    NASA Astrophysics Data System (ADS)

    Dimbylow, Peter

    2005-09-01

    Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.

  15. Resonance behaviour of whole-body averaged specific energy absorption rate (SAR) in the female voxel model, NAOMI.

    PubMed

    Dimbylow, Peter

    2005-09-07

    Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.

  16. A physiologically based pharmacokinetic model for lactational transfer of Na-131I

    NASA Astrophysics Data System (ADS)

    Turner, Anita Loretta

    The excretion of radionuclides in human breast milk after administration of radiopharmaceuticals is a concern as a radiation risk to nursing infants. It is not uncommon to administer radiopharmaceuticals to lactating patients due to emergency nuclear medicine investigations such as thyroid complications, kidney failure, and pulmonary embolism. There is a need to quantify the amount of radioactivity translocated into breast milk in cases of ingestion by a breast-fed infant. A physiologically based pharmacokinetic model (PBPK) and a modified International Commission on Radiological Protection (ICRP) model have been developed to predict iodine concentrations in breast milk after ingestion of radioiodine by the mother. In the PBPK model, all compartments are interconnected by blood flow and represent real anatomic tissue regions in the body. All parameters involved are measurable values with physiological or physiochemical meaning such as tissue masses, blood flow rates, partition coefficients and cardiac output. However, some of the parameters such as the partition coefficients and metabolic constants are not available for iodine and had to be inferred from other information. The structure of the PBPK model for the mother consists of the following tissue compartments: gastrointestinal tract, blood, kidney, thyroid, milk, and other tissues. With the exception of the milk compartment, the model for the nursing infant is structured similarly to the mother. The ICRP model describing iodine metabolism in a standard 70-kg man was modified to represent iodine metabolism in a lactating woman and nursing infant. The parameters involved in this model are transfer rates and biological half-lives which are based on experimental observations. The results of the PBPK model and the modified ICRP model describing the lactational transfer of iodine were compared. When administering 1 mCi of Na131I to the lactating mother, the concentration reaches a maximum of 0.1 mCi/liter in 24

  17. Discrimination of dynamical system models for biological and chemical processes.

    PubMed

    Lorenz, Sönke; Diederichs, Elmar; Telgmann, Regina; Schütte, Christof

    2007-06-01

    In technical chemistry, systems biology and biotechnology, the construction of predictive models has become an essential step in process design and product optimization. Accurate modelling of the reactions requires detailed knowledge about the processes involved. However, when concerned with the development of new products and production techniques for example, this knowledge often is not available due to the lack of experimental data. Thus, when one has to work with a selection of proposed models, the main tasks of early development is to discriminate these models. In this article, a new statistical approach to model discrimination is described that ranks models wrt. the probability with which they reproduce the given data. The article introduces the new approach, discusses its statistical background, presents numerical techniques for its implementation and illustrates the application to examples from biokinetics.

  18. Comparisons of lung tumour mortality risk in the Japanese A-bomb survivors and in the Colorado Plateau uranium miners: support for the ICRP lung model.

    PubMed

    Little, M P

    2002-03-01

    assumptions as to the definition of lung cancer in the Colorado data, or by excluding miners for whom exposure estimates may be less reliable, are very similar. The absence of information on cigarette smoking in the Japanese A-bomb survivors, and the possibility that this may confound the time trends in radiation-induced lung cancer risk in that cohort, imply that these findings should be interpreted with caution. There are no statistically significant differences between the male A-bomb survivors data and the Colorado miner data in the pattern of variation of relative risk with time after exposure and age at exposure. The risk conversion factor is very close to the value suggested by the latest ICRP lung model, albeit with substantial uncertainties.

  19. Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110

    NASA Astrophysics Data System (ADS)

    Galeano, D. C.; Santos, W. S.; Alves, M. C.; Souza, D. N.; Carvalho, A. B.

    2016-04-01

    The aim of this work was to modify the standing posture of the anthropomorphic reference phantoms of ICRP publication 110, AM (Adult Male) and AF (Adult Female), to the sitting posture. The change of posture was performed using the Visual Monte Carlo software (VMC) to rotate the thigh region of the phantoms and position it between the region of the leg and trunk. Scion Image software was used to reconstruct and smooth the knee and hip contours of the phantoms in a sitting posture. For 3D visualization of phantoms, the VolView software was used. In the change of postures, the organ and tissue masses were preserved. The MCNPX was used to calculate the equivalent and effective dose conversion coefficients (CCs) per fluence for photons for six irradiation geometries suggested by ICRP publication 110 (AP, PA, RLAT, LLAT, ROT and ISO) and energy range 0.010-10 MeV. The results were compared between the standing and sitting postures, for both sexes, in order to evaluate the differences of scattering and absorption of radiation for different postures. Significant differences in the CCs for equivalent dose were observed in the gonads, colon, prostate, urinary bladder and uterus, which are present in the pelvic region, and in organs distributed throughout the body, such as the lymphatic nodes, muscle, skeleton and skin, for the phantoms of both sexes. CCs for effective dose showed significant differences of up to 16% in the AP irradiation geometry, 27% in the PA irradiation geometry and 13% in the ROT irradiation geometry. These results demonstrate the importance of using phantoms in different postures in order to obtain more precise conversion coefficients for a given exposure scenario.

  20. From Technique of Tattooing to Biokinetics and Toxicology of Injected Tattoo Ink Particles and Chemicals.

    PubMed

    Serup, Jørgen

    2017-01-01

    Tattoo colourants are colourful nano- and microparticles, which are practically insoluble and thus permanent once installed in the dermis by the tattooist. Tattoo ink also has soluble ingredients and contaminants. Pigments can distribute via the lymph and possibly also directly to the blood, and a minute fraction may over time undergo metabolic breakdown and as hapten(s) induce allergic reactions of red tattoos. Carbon black of black tattoos has a tendency to agglomerate and form larger bodies that can elicit foreign body reactions in black tattoos and even granuloma formation with overlap to sarcoidosis in the clinic. Very little is known about the biokinetics and safety profile of the many tattoo pigments in use, and no specific pigment-related chemical of tattoo ink causing identified adverse reactions in humans has been depicted. Inks have many ingredients and contaminants. Insoluble and soluble ingredients of inks supposedly have very different characteristics of absorption, distribution, metabolism, and excretion, with pigments being extremely slowly excreted, contrasting soluble ingredients with fast elimination. Tattoos are a single-dose exposure. Controlling the safety of tattoo inks by banning potentially critical chemicals hitherto has been unsuccessful due to lacking documentation of clinical and epidemiological relevance and because the tattoo industry is already internationally established, free, and in the ownership of the people. Doctors treating patients with tattoo complications consequently have a key role in identifying risk situations and local outbreaks, which needs clarification, therapy, and the intervention of authorities. In the treatment of complications, as seen in general practice and in other specialties, basic insight into the fate of tattoo pigments in the body is necessary. Tattoo complications are complicated and facetted with many entities and disease mechanisms; they are a new subspecialty in medicine and dermatology. © 2017 S

  1. Radiological Protection Issues Arising During and After the Fukushima Nuclear Reactor Accident-Memorandum of TG 84 of ICRP.

    PubMed

    Weiss, Wolfgang

    2016-09-01

    Observations and lessons identified after the Fukushima accident have been collected and assessed by ICRP Task Group 84. Together with the observations of other expert organizations, they are being used to further develop the current system of protection. While many of the established protection criteria remain valid, improvements are needed in three areas. Key issues related to the need of planning for long-term protective actions (criteria for returning home, dealing with waste) have to be implemented as important elements of the national protection strategies during the preparedness stage. The justification of disruptive protective actions and the protection of vulnerably groups of the population need to be reconsidered to avoid unpleasant imbalances and outcomes. The coexistence of radiation-induced health effects and health effects with social determinants requires consideration of both aspects in decision-making and response. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Towards a consensus-based biokinetic model for green microalgae - The ASM-A.

    PubMed

    Wágner, Dorottya S; Valverde-Pérez, Borja; Sæbø, Mariann; Bregua de la Sotilla, Marta; Van Wagenen, Jonathan; Smets, Barth F; Plósz, Benedek Gy

    2016-10-15

    Cultivation of microalgae in open ponds and closed photobioreactors (PBRs) using wastewater resources offers an opportunity for biochemical nutrient recovery. Effective reactor system design and process control of PBRs requires process models. Several models with different complexities have been developed to predict microalgal growth. However, none of these models can effectively describe all the relevant processes when microalgal growth is coupled with nutrient removal and recovery from wastewaters. Here, we present a mathematical model developed to simulate green microalgal growth (ASM-A) using the systematic approach of the activated sludge modelling (ASM) framework. The process model - identified based on a literature review and using new experimental data - accounts for factors influencing photoautotrophic and heterotrophic microalgal growth, nutrient uptake and storage (i.e. Droop model) and decay of microalgae. Model parameters were estimated using laboratory-scale batch and sequenced batch experiments using the novel Latin Hypercube Sampling based Simplex (LHSS) method. The model was evaluated using independent data obtained in a 24-L PBR operated in sequenced batch mode. Identifiability of the model was assessed. The model can effectively describe microalgal biomass growth, ammonia and phosphate concentrations as well as the phosphorus storage using a set of average parameter values estimated with the experimental data. A statistical analysis of simulation and measured data suggests that culture history and substrate availability can introduce significant variability on parameter values for predicting the reaction rates for bulk nitrate and the intracellularly stored nitrogen state-variables, thereby requiring scenario specific model calibration. ASM-A was identified using standard cultivation medium and it can provide a platform for extensions accounting for factors influencing algal growth and nutrient storage using wastewater resources. Copyright

  3. Quantifying annual internal effective 137Cesium dose utilizing direct body-burden measurement and ecological dose modeling.

    PubMed

    Jelin, Benjamin A; Sun, Wenjie; Kravets, Alexandra; Naboka, Maryna; Stepanova, Eugenia I; Vdovenko, Vitaliy Y; Karmaus, Wilfried J; Lichosherstov, Alex; Svendsen, Erik R

    2016-11-01

    The Chernobyl Nuclear Power Plant (CNPP) accident represents one of the most significant civilian releases of 137 Cesium ( 137 Cs, radiocesium) in human history. In the Chernobyl-affected region, radiocesium is considered to be the greatest on-going environmental hazard to human health by radiobiologists and public health scientists. The goal of this study was to characterize dosimetric patterns and predictive factors for whole-body count (WBC)-derived radiocesium internal dose estimations in a CNPP-affected children's cohort, and cross-validate these estimations with a soil-based ecological dose estimation model. WBC data were used to estimate the internal effective dose using the International Commission on Radiological Protection (ICRP) 67 dose conversion coefficient for 137 Cs and MONDAL Version 3.01 software. Geometric mean dose estimates from each model were compared utilizing paired t-tests and intra-class correlation coefficients. Additionally, we developed predictive models for WBC-derived dose estimation in order to determine the appropriateness of EMARC to estimate dose for this population. The two WBC-derived dose predictive models identified 137 Cs soil concentration (P<0.0001) as the strongest predictor of annual internal effective dose from radiocesium validating the use of the soil-based EMARC model. The geometric mean internal effective dose estimate of the EMARC model (0.183 mSv/y) was the highest followed by the ICRP 67 dose estimates (0.165 mSv/y) and the MONDAL model estimates (0.149 mSv/y). All three models yielded significantly different geometric mean dose (P<0.05) estimates for this cohort when stratified by sex, age at time of exam and season of exam, except for the mean MONDAL and EMARC estimates for 15- and 16-year olds and mean ICRP and MONDAL estimates for children examined in Winter. Further prospective and retrospective radio-epidemiological studies utilizing refined WBC measurements and ecological model dose estimations, in

  4. Implications of human tissue studies for radiation protection.

    PubMed

    Kathren, R L

    1988-08-01

    Through radiochemical analysis of voluntary tissue donations, the U.S. Transuranium and Uranium Registries (USTR) are gaining improved understanding of the distribution and biokinetics of actinide elements in occupationally exposed persons. Evaluation of the first two whole-body contributions to the USTR revealed an inverse proportionality between actinide concentration and bone ash. The analysis of a whole body with significant 241Am deposition indicated a significantly shorter half-time in liver and a greater fraction resident in the skeleton than predicted by existing models. Other studies with tissues obtained at autopsy suggest that existing biokinetic models for 238Pu and 241Am and the currently accepted models and limits on intake, which use these models as their basis, may be inaccurately implying that revisions of existing safety standards may be necessary. Other studies of the registries are designed to evaluate in-vivo estimates of actinide deposition with those derived from postmortem tissue analysis, to compare results of animal experiments with human data, and to review histopathologic slides for tissue changes that might be attributable to exposure to transuranic elements. The implications of these recent findings and other work of the registries is discussed from the standpoint of this potential effect on biokinetic modeling, internal dose assessment, and safety standards and operational health physics practices.

  5. Kit preparation and biokinetics in women of 99mTc-EDDA/HYNIC-E-[c(RGDfK)]2 for breast cancer imaging.

    PubMed

    Ortiz-Arzate, Zareth; Santos-Cuevas, Clara L; Ocampo-García, Blanca E; Ferro-Flores, Guillermina; García-Becerra, Rocío; Estrada, Gisela; Gómez-Argumosa, Edgar; Izquierdo-Sánchez, Vanessa

    2014-04-01

    In breast cancer, α(ν)β(3) and/or α(ν)β(5) integrins are overexpressed in both endothelial and tumour cells. Radiolabelled peptides based on the Arg-Gly-Asp (RGD) sequence are radiopharmaceuticals with high affinity and selectivity for these integrins. The RGD-dimer peptide (E-[c(RGDfK)]2) radiolabelled with (99m)Tc has been reported as a radiopharmaceutical with a 10-fold higher affinity for the α(ν)β(3) integrin compared with the RGD-monomer. Ethylenediamine-N,N'-diacetic acid (EDDA) is a hydrophilic molecule that may favour renal excretion when used as coligand in the (99m)Tc labelling of hydrazinonicotinamide (HYNIC) peptides and can easily be formulated in a lyophilized kit. The aim of this study was to establish a biokinetic model for (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 prepared from lyophilized kits and evaluate its dosimetry as a tumour-imaging agent in seven healthy women and three breast cancer patients. (99m)Tc labelling was performed by adding sodium pertechnetate solution and 0.2 mol/l phosphate buffer (pH 7.0) to a lyophilized formulation containing E-[c(RGDfK)]2, EDDA, tricine, mannitol and stannous chloride. The radiochemical purity was evaluated using reverse-phase high-performance liquid chromatography and instant thin-layer chromatography on silica gel analyses. Stability studies in human serum were carried out using size-exclusion high-performance liquid chromatography. In-vitro cell uptake was tested using breast cancer cells (MCF7, T47D and MDA-MB-231) with blocked and nonblocked receptors. Biodistribution and tumour uptake were determined in MCF7 tumour-bearing nude mice with blocked and nonblocked receptors, and images were obtained using a micro-SPECT/PET/CT. Whole-body images from seven healthy women were acquired at 0.5, 1, 3, 6 and 24 h after (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 administration with radiochemical purities greater than 94%. Regions of interest were drawn around the source organs at each time frame. Each region of

  6. A kinematic model to estimate effective dose of radioactive substances in a human body

    NASA Astrophysics Data System (ADS)

    Sasaki, S.; Yamada, T.

    2013-05-01

    The great earthquake occurred in the north-east area in Japan in March 11, 2011. Facility system to control Fukushima Daiichi nuclear power station was completely destroyed by the following giant tsunami. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and diffused in the vicinity of this station. Radiological internal exposure became a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplifying the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed a sophisticated model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that ICRP method is fine, it is rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional tank model in hydrology. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of the present method is to estimate the energy radiated in the radioactive nuclear disintegration of an atom by using classical theory of β decay and special relativity for various kinds of radioactive atoms. The parameters used in this model are only physical half-time and biological half-time, and there are no operational parameters or coefficients to adjust our theoretical runoff to ICRP. Figure shows the time-varying effective dose with ingestion duration, and we can confirm the validity of our model. The time-varying effective dose with

  7. Shall we upgrade one-dimensional secondary settler models used in WWTP simulators? - An assessment of model structure uncertainty and its propagation.

    PubMed

    Plósz, Benedek Gy; De Clercq, Jeriffa; Nopens, Ingmar; Benedetti, Lorenzo; Vanrolleghem, Peter A

    2011-01-01

    In WWTP models, the accurate assessment of solids inventory in bioreactors equipped with solid-liquid separators, mostly described using one-dimensional (1-D) secondary settling tank (SST) models, is the most fundamental requirement of any calibration procedure. Scientific knowledge on characterising particulate organics in wastewater and on bacteria growth is well-established, whereas 1-D SST models and their impact on biomass concentration predictions are still poorly understood. A rigorous assessment of two 1-DSST models is thus presented: one based on hyperbolic (the widely used Takács-model) and one based on parabolic (the more recently presented Plósz-model) partial differential equations. The former model, using numerical approximation to yield realistic behaviour, is currently the most widely used by wastewater treatment process modellers. The latter is a convection-dispersion model that is solved in a numerically sound way. First, the explicit dispersion in the convection-dispersion model and the numerical dispersion for both SST models are calculated. Second, simulation results of effluent suspended solids concentration (XTSS,Eff), sludge recirculation stream (XTSS,RAS) and sludge blanket height (SBH) are used to demonstrate the distinct behaviour of the models. A thorough scenario analysis is carried out using SST feed flow rate, solids concentration, and overflow rate as degrees of freedom, spanning a broad loading spectrum. A comparison between the measurements and the simulation results demonstrates a considerably improved 1-D model realism using the convection-dispersion model in terms of SBH, XTSS,RAS and XTSS,Eff. Third, to assess the propagation of uncertainty derived from settler model structure to the biokinetic model, the impact of the SST model as sub-model in a plant-wide model on the general model performance is evaluated. A long-term simulation of a bulking event is conducted that spans temperature evolution throughout a summer

  8. In Vitro Measurements of Metabolism for Application in Pharmacokinetic Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lipscomb, John C.; Poet, Torka S.

    2008-04-01

    Abstract Human risk and exposure assessments require dosimetry information. Species-specific tissue dose response will be driven by physiological and biochemical processes. While metabolism and pharmacokinetic data are often not available in humans, they are much more available in laboratory animals; metabolic rate constants can be readily derived in vitro. The physiological differences between laboratory animals and humans are known. Biochemical processes, especially metabolism, can be measured in vitro and extrapolated to account for in vivo metabolism through clearance models or when linked to a physiologically based biological (PBPK) model to describe the physiological processes, such as drug delivery to themore » metabolic organ. This review focuses on the different organ, cellular, and subcellular systems that can be used to measure in vitro metabolic rate constants and how that data is extrapolated to be used in biokinetic modeling.« less

  9. Human biokinetics of strontium. Part I: intestinal absorption rate and its impact on the dose coefficient of 90Sr after ingestion.

    PubMed

    Li, Wei Bo; Höllriegl, Vera; Roth, Paul; Oeh, Uwe

    2006-07-01

    Intestinal absorption of strontium (Sr) in thirteen healthy adult German volunteers has been investigated by simultaneous oral and intravenous administration of two stable tracer isotopes, i.e. (84)Sr and (86)Sr. The measured Sr tracer concentration in plasma was analyzed using the convolution integral technique to obtain the intestinal absorption rate. The results showed that the Sr labeled in different foodstuffs was absorbed into the body fluids in a large range of difference. The maximum Sr absorption rates were observed within 60-120 min after administration. The rate of absorption is used to evaluate the intestinal absorption fraction, i.e. the f (1) value for various foodstuffs. The equivalent and effective dose coefficients for ingestion of (90)Sr were calculated using these f (1) values, and they were compared with those recommended by the International Commission on Radiological Protection (ICRP). The geometric and arithmetic means of the f (1) values are 0.38 and 0.45 associated with a geometric standard deviation and a standard deviation of 1.88 and 0.22, respectively. The 90% confidence interval of the f (1) values obtained in the present study ranges from 0.13 to 0.98. Expressed as the ratio of the 95 and 50% percentiles of the estimated probability, the uncertainty for the f (1) value corresponds to a factor of 2.58. The effective dose coefficients of (90)Sr after ingestion are 6.1 x 10(-9) Sv Bq(-1) for an f(1) value of 0.05, 1.0 x 10(-8) Sv Bq(-1) for 0.1, 1.9 x 10(-8) Sv Bq(-1) for 0.2, 2.8 x 10(-8) Sv Bq(-1) for 0.3, 3.6 x 10(-8) Sv Bq(-1) for 0.4, 5.3 x 10(-8) Sv Bq(-1) for 0.6, 7.1 x 10(-8) Sv Bq(-1) for 0.8, and 7.9 x 10(-8) Sv Bq(-1) for 0.9, respectively. Taking the effective dose coefficient of 2.8 x 10(-8) Sv Bq(-1) for an f (1) value of 0.3, which is recommended by the ICRP, as a reference, the effective dose coefficient of (90)Sr after ingestion varies by a factor of 2.8 when the f (1) value changes by a factor of 3, i.e. it decreases

  10. Critical Dose of Internal Organs Internal Exposure - 13471

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigoryan, G.; Amirjanyan, A.; Grigoryan, N.

    2013-07-01

    The health threat posed by radionuclides has stimulated increased efforts to developed characterization on the biological behavior of radionuclides in humans in all ages. In an effort motivated largely by the Chernobyl nuclear accident, the International Commission on Radiological Protection (ICRP) is assembling a set of age specific biokinetic models for environmentally important radioelements. Radioactive substances in the air, mainly through the respiratory system and digestive tract, is inside the body. Radioactive substances are unevenly distributed in various organs and tissues. Therefore, the degree of damage will depend not only on the dose of radiation have but also on themore » critical organ, which is the most accumulation of radioactive substances, which leads to the defeat of the entire human body. The main objective of radiation protection, to avoid exceeding the maximum permissible doses of external and internal exposure of a person to prevent the physical and genetic damage people. The maximum tolerated dose (MTD) of radiation is called a dose of radiation a person in uniform getting her for 50 years does not cause changes in the health of the exposed individual and his progeny. The following classification of critical organs, depending on the category of exposure on their degree of sensitivity to radiation: First group: the whole body, gonads and red bone marrow; Second group: muscle, fat, liver, kidney, spleen, gastrointestinal tract, lungs and lens of the eye; The third group: bone, thyroid and skin; Fourth group: the hands, forearms, feet. MTD exposure whole body, gonads and bone marrow represent the maximum exposures (5 rem per year) experienced by people in their normal activities. The purpose of this article is intended dose received from various internal organs of the radionuclides that may enter the body by inhalation, and gastrointestinal tract. The biokinetic model describes the time dependent distribution and excretion of different

  11. Implications of human tissue studies for radiation protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.

    1988-08-01

    Through radiochemical analysis of voluntary tissue donations, the U.S. Transuranium and Uranium Registries (USTR) are gaining improved understanding of the distribution and biokinetics of actinide elements in occupationally exposed persons. Evaluation of the first two whole-body contributions to the USTR revealed an inverse proportionality between actinide concentration and bone ash. The analysis of a whole body with significant /sup 241/Am deposition indicated a significantly shorter half-time in liver and a greater fraction resident in the skeleton than predicted by existing models. Other studies with tissues obtained at autopsy suggest that existing biokinetic models for /sup 238/Pu and /sup 241/Am andmore » the currently accepted models and limits on intake, which use these models as their basis, may be inaccurately implying that revisions of existing safety standards may be necessary. Other studies of the registries are designed to evaluate in-vivo estimates of actinide deposition with those derived from postmortem tissue analysis, to compare results of animal experiments with human data, and to review histopathologic slides for tissue changes that might be attributable to exposure to transuranic elements. The implications of these recent findings and other work of the registries is discussed from the standpoint of this potential effect on biokinetic modeling, internal dose assessment, and safety standards and operational health physics practices.« less

  12. Experimental and theoretical study of the transport of silver nanoparticles at their prolonged administration into a mammal organism

    NASA Astrophysics Data System (ADS)

    Antsiferova, A. A.; Buzulukov, Yu. P.; Kashkarov, P. K.; Kovalchuk, M. V.

    2016-11-01

    The transport of silver nanoparticles in the organism of laboratory animals has been investigated. A mathematical model of the biokinetics of prolonged administration of nonmetabolizable and nonaglomerating pharmaceutical preparations is proposed, and its analytical solution is found. Based on the experimental data on the prolonged introduction and excretion of colloidal silver nanoparticles and the numerical approximation of the solutions to the equations for the proposed model, time dependences of the silver mass content in brain and blood are obtained and some other important biokinetic parameters are determined. It is concluded that both chronic1 and subchronic2 peroral application of these nanoparticles as an biologically active additive or antiseptic is potentially dangerous.

  13. A DISCUSSION ON DIFFERENT APPROACHES FOR ASSESSING LIFETIME RISKS OF RADON-INDUCED LUNG CANCER.

    PubMed

    Chen, Jing; Murith, Christophe; Palacios, Martha; Wang, Chunhong; Liu, Senlin

    2017-11-01

    Lifetime risks of radon induced lung cancer were assessed based on epidemiological approaches for Canadian, Swiss and Chinese populations, using the most recent vital statistic data and radon distribution characteristics available for each country. In the risk calculation, the North America residential radon risk model was used for the Canadian population, the European residential radon risk model for the Swiss population, the Chinese residential radon risk model for the Chinese population, and the EPA/BEIR-VI radon risk model for all three populations. The results were compared with the risk calculated from the International Commission on Radiological Protection (ICRP)'s exposure-to-risk conversion coefficients. In view of the fact that the ICRP coefficients were recommended for radiation protection of all populations, it was concluded that, generally speaking, lifetime absolute risks calculated with ICRP-recommended coefficients agree reasonably well with the range of radon induced lung cancer risk predicted by risk models derived from epidemiological pooling analyses. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

    PubMed

    2002-01-01

    This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations

  15. Radiation absorbed dose estimates for 18F-BPA PET.

    PubMed

    Kono, Yuzuru; Kurihara, Hiroaki; Kawamoto, Hiroshi; Yasui, Naoko; Honda, Naoki; Igaki, Hiroshi; Itami, Jun

    2017-09-01

    Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the 10 B (n, α) 7 Li nuclear reaction in cancer cells. In BNCT, delivery of 10 B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

  16. Automated workflows for modelling chemical fate, kinetics and toxicity.

    PubMed

    Sala Benito, J V; Paini, Alicia; Richarz, Andrea-Nicole; Meinl, Thorsten; Berthold, Michael R; Cronin, Mark T D; Worth, Andrew P

    2017-12-01

    Automation is universal in today's society, from operating equipment such as machinery, in factory processes, to self-parking automobile systems. While these examples show the efficiency and effectiveness of automated mechanical processes, automated procedures that support the chemical risk assessment process are still in their infancy. Future human safety assessments will rely increasingly on the use of automated models, such as physiologically based kinetic (PBK) and dynamic models and the virtual cell based assay (VCBA). These biologically-based models will be coupled with chemistry-based prediction models that also automate the generation of key input parameters such as physicochemical properties. The development of automated software tools is an important step in harmonising and expediting the chemical safety assessment process. In this study, we illustrate how the KNIME Analytics Platform can be used to provide a user-friendly graphical interface for these biokinetic models, such as PBK models and VCBA, which simulates the fate of chemicals in vivo within the body and in vitro test systems respectively. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Biokinetic modelling development and analysis of arsenic dissolution into the gastrointestinal tract using SAAM II

    NASA Astrophysics Data System (ADS)

    Perama, Yasmin Mohd Idris; Siong, Khoo Kok

    2018-04-01

    A mathematical model comprising 8 compartments were designed to describe the kinetic dissolution of arsenic (As) from water leach purification (WLP) waste samples ingested into the gastrointestinal system. A totally reengineered software system named Simulation, Analysis and Modelling II (SAAM II) was employed to aid in the experimental design and data analysis. As a powerful tool that creates, simulate and analyze data accurately and rapidly, SAAM II computationally creates a system of ordinary differential equations according to the specified compartmental model structure and simulates the solutions based upon the parameter and model inputs provided. The experimental design of in vitro DIN approach was applied to create an artificial gastric and gastrointestinal fluids. These synthetic fluids assay were produced to determine the concentrations of As ingested into the gastrointestinal tract. The model outputs were created based upon the experimental inputs and the recommended fractional transfer rates parameter. As a result, the measured and predicted As concentrations in gastric fluids were much similar against the time of study. In contrast, the concentrations of As in the gastrointestinal fluids were only similar during the first hour and eventually started decreasing until the fifth hours of study between the measured and predicted values. This is due to the loss of As through the fractional transfer rates of q2 compartment to corresponding compartments of q3 and q5 which are involved with excretion and distribution to the whole body, respectively. The model outputs obtained after best fit to the data were influenced significantly by the fractional transfer rates between each compartment. Therefore, a series of compartmental model created with the association of fractional transfer rates parameter with the aid of SAAM II provides better estimation that simulate the kinetic behavior of As ingested into the gastrointestinal system.

  18. 2012 Children's Health Protection Advisory Committee Letters

    EPA Pesticide Factsheets

    These two letters address National Ambient Air Quality Standards proposed for particulate matter (PM), and childhood lead poisoning prevention particularly as regards revision of the Integrated Exposure Uptake Biokinetic model.

  19. Computational lymphatic node models in pediatric and adult hybrid phantoms for radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Lee, Choonsik; Lamart, Stephanie; Moroz, Brian E.

    2013-03-01

    We developed models of lymphatic nodes for six pediatric and two adult hybrid computational phantoms to calculate the lymphatic node dose estimates from external and internal radiation exposures. We derived the number of lymphatic nodes from the recommendations in International Commission on Radiological Protection (ICRP) Publications 23 and 89 at 16 cluster locations for the lymphatic nodes: extrathoracic, cervical, thoracic (upper and lower), breast (left and right), mesentery (left and right), axillary (left and right), cubital (left and right), inguinal (left and right) and popliteal (left and right), for different ages (newborn, 1-, 5-, 10-, 15-year-old and adult). We modeled each lymphatic node within the voxel format of the hybrid phantoms by assuming that all nodes have identical size derived from published data except narrow cluster sites. The lymph nodes were generated by the following algorithm: (1) selection of the lymph node site among the 16 cluster sites; (2) random sampling of the location of the lymph node within a spherical space centered at the chosen cluster site; (3) creation of the sphere or ovoid of tissue representing the node based on lymphatic node characteristics defined in ICRP Publications 23 and 89. We created lymph nodes until the pre-defined number of lymphatic nodes at the selected cluster site was reached. This algorithm was applied to pediatric (newborn, 1-, 5-and 10-year-old male, and 15-year-old males) and adult male and female ICRP-compliant hybrid phantoms after voxelization. To assess the performance of our models for internal dosimetry, we calculated dose conversion coefficients, called S values, for selected organs and tissues with Iodine-131 distributed in six lymphatic node cluster sites using MCNPX2.6, a well validated Monte Carlo radiation transport code. Our analysis of the calculations indicates that the S values were significantly affected by the location of the lymph node clusters and that the values increased for

  20. Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

    PubMed

    Liu, Dan; Khong, Pek-Lan; Gao, Yiming; Mahmood, Usman; Quinn, Brian; St Germain, Jean; Xu, X George; Dauer, Lawrence T

    2016-06-01

    Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. Consecutive adult patients with hepatocellular carcinoma who underwent whole-body dual-tracer PET/CT scans were retrospectively reviewed with institutional review board approval. OLINDA/EXM 1.1 was used to estimate patient-specific internal dose exposure in each organ. Biokinetic models for (18)F-FDG and (11)C-acetate as provided by ICRP (International Commission on Radiological Protection) publication 106 were used. Standard reference phantoms were modified to more closely represent patient-specific organ mass. With patient-specific parameters, organ equivalent doses from each CT series were estimated using VirtualDose. Dosimetry capabilities for tube current modulation protocols were applied by integrating with the latest anatomic realistic models. Effective dose was calculated using ICRP publication 103 tissue-weighting coefficients for adult male and female, respectively. Fourteen scans were evaluated (12 men, 2 women; mean age ± SD, 60 ± 19.48 y). The patient-specific effective dose from (18)F-FDG and (11)C-acetate was 6.08 ± 1.49 and 1.56 ± 0.47 mSv, respectively, for male patients and 6.62 ± 1.38 and 1.79 ± 0.12 mSV, respectively, for female patients. The patient-specific effective dose of the CT component, which comprised 2 noncontrast whole-body scans, to male and female patients was 21.20 ± 8.94 and 14.79 ± 3.35 mSv, respectively. Thus, the total effective doses of the combined whole-body dual-tracer PET/CT studies for male and female patients were 28.84 ± 10.18 and 23.19 ± 4.61 mSv, respectively. Patient-specific parameters allow for more accurate estimation of organ equivalent doses. Considering the substantial

  1. Dose estimation for astronauts using dose conversion coefficients calculated with the PHITS code and the ICRP/ICRU adult reference computational phantoms.

    PubMed

    Sato, Tatsuhiko; Endo, Akira; Sihver, Lembit; Niita, Koji

    2011-03-01

    Absorbed-dose and dose-equivalent rates for astronauts were estimated by multiplying fluence-to-dose conversion coefficients in the units of Gy.cm(2) and Sv.cm(2), respectively, and cosmic-ray fluxes around spacecrafts in the unit of cm(-2) s(-1). The dose conversion coefficients employed in the calculation were evaluated using the general-purpose particle and heavy ion transport code system PHITS coupled to the male and female adult reference computational phantoms, which were released as a common ICRP/ICRU publication. The cosmic-ray fluxes inside and near to spacecrafts were also calculated by PHITS, using simplified geometries. The accuracy of the obtained absorbed-dose and dose-equivalent rates was verified by various experimental data measured both inside and outside spacecrafts. The calculations quantitatively show that the effective doses for astronauts are significantly greater than their corresponding effective dose equivalents, because of the numerical incompatibility between the radiation quality factors and the radiation weighting factors. These results demonstrate the usefulness of dose conversion coefficients in space dosimetry. © Springer-Verlag 2010

  2. High Throughput PBPK: Evaluating EPA's Open-Source Data and Tools for Dosimetry and Exposure Reconstruction (SOT)

    EPA Science Inventory

    To address this need, new tools have been created for characterizing, simulating, and evaluating chemical biokinetics. Physiologically-based pharmacokinetic (PBPK) models provide estimates of chemical exposures that produce potentially hazardous tissue concentrations, while tissu...

  3. Katja — the 24th week of virtual pregnancy for dosimetric calculations

    NASA Astrophysics Data System (ADS)

    Becker, Janine; Zankl, Maria; Fill, Ute; Hoeschen, Christoph

    2008-01-01

    Virtual human models, a.k.a. voxel models, are currently the state of the art in radiation protection for computing organ irradiation doses without difficult or morally unfeasible experiments. They are based on medical image data of human patients and offer a realistic, three dimensional representation of human anatomy. We present our newest voxel model Katja, a virtual woman in the 24th week of pregnancy. Katja integrates two previous voxel models, one obtained from the abdominal MRI scan of a pregnant patient and an already segmented model of a non-pregnant woman. The latter is the ICRP-AF, fitting the reference values for standard height, weight and organ masses given by the Internationals Committee of Radiological Protection (ICRP). The dataset was altered in order to fit the segmented foetus taken from the abdominal MRI scan. The resulting pregnant woman model, Katja, complies with the ICRP reference values for the adult female.

  4. RACEWAY REACTOR FOR MICROALGAL BIODIESEL PRODUCTION

    EPA Science Inventory

    The proposed mathematical model incorporating mass transfer, hydraulics, carbonate/aquatic chemistry, biokinetics, biology and reactor design will be calibrated and validated using the data to be generated from the experiments. The practical feasibility of the proposed reactor...

  5. 42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...

  6. 42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...

  7. 42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...

  8. 42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...

  9. 42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...

  10. Current knowledge on radon risk: implications for practical radiation protection? radon workshop, 1/2 December 2015, Bonn, BMUB (Bundesministerium für Umwelt, Naturschutz, Bau und Reaktorsicherheit; Federal Ministry for the Environment, Nature Conservation, Building and Nuclear Safety).

    PubMed

    Müller, Wolfgang-Ulrich; Giussani, Augusto; Rühm, Werner; Lecomte, Jean-Francois; Harrison, John; Kreuzer, Michaela; Sobotzki, Christina; Breckow, Joachim

    2016-08-01

    ICRP suggested a strategy based on the distinction between a protection approach for dwellings and one for workplaces in the previous recommendations on radon. Now, the Commission recommends an integrated approach for the protection against radon exposure in all buildings irrespective of their purpose and the status of their occupants. The strategy of protection in buildings, implemented through a national action plan, is based on the application of the optimisation principle below a derived reference level in concentration (maximum 300 Bq m(-3)). A problem, however, arises that due to new epidemiological findings and application of dosimetric models, ICRP 115 (Ann ICRP 40, 2010) presents nominal probability coefficients for radon exposure that are approximately by a factor of 2 larger than in the former recommendations of ICRP 65 (Ann ICRP 23, 1993). On the basis of the so-called epidemiological approach and the dosimetric approach, the doubling of risk per unit exposure is represented by a doubling of the dose coefficients, while the risk coefficient of ICRP 103 (2007) remains unchanged. Thus, an identical given radon exposure situation with the new dose coefficients would result in a doubling of dose compared with the former values. This is of serious conceptual implications. A possible solution of this problem was presented during the workshop.

  11. An image-based skeletal dosimetry model for the ICRP reference newborn—internal electron sources

    NASA Astrophysics Data System (ADS)

    Pafundi, Deanna; Rajon, Didier; Jokisch, Derek; Lee, Choonsik; Bolch, Wesley

    2010-04-01

    In this study, a comprehensive electron dosimetry model of newborn skeletal tissues is presented. The model is constructed using the University of Florida newborn hybrid phantom of Lee et al (2007 Phys. Med. Biol. 52 3309-33), the newborn skeletal tissue model of Pafundi et al (2009 Phys. Med. Biol. 54 4497-531) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow (surrogate tissue for hematopoietic stem cells), shallow marrow (surrogate tissue for osteoprogenitor cells) and unossified cartilage (surrogate tissue for chondrocytes). Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following source tissues: active marrow, trabecular bone (surfaces and volumes), cortical bone (surfaces and volumes) and cartilage. Transport results are reported as specific absorbed fractions according to the MIRD schema and are given as skeletal-averaged values in the paper with bone-specific values reported in both tabular and graphic format as electronic annexes (supplementary data). The method utilized in this work uniquely includes (1) explicit accounting for the finite size and shape of newborn ossification centers (spongiosa regions), (2) explicit accounting for active and shallow marrow dose from electron emissions in cortical bone as well as sites of unossified cartilage, (3) proper accounting of the distribution of trabecular and cortical volumes and surfaces in the newborn skeleton when considering mineral bone sources and (4) explicit consideration of the marrow cellularity changes for active marrow self-irradiation as applicable to radionuclide therapy of diseased marrow in the newborn child.

  12. Time-integrated activity coefficient estimation for radionuclide therapy using PET and a pharmacokinetic model: A simulation study on the effect of sampling schedule and noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardiansyah, Deni

    2016-09-15

    Purpose: The aim of this study was to investigate the accuracy of PET-based treatment planning for predicting the time-integrated activity coefficients (TIACs). Methods: The parameters of a physiologically based pharmacokinetic (PBPK) model were fitted to the biokinetic data of 15 patients to derive assumed true parameters and were used to construct true mathematical patient phantoms (MPPs). Biokinetics of 150 MBq {sup 68}Ga-DOTATATE-PET was simulated with different noise levels [fractional standard deviation (FSD) 10%, 1%, 0.1%, and 0.01%], and seven combinations of measurements at 30 min, 1 h, and 4 h p.i. PBPK model parameters were fitted to the simulated noisymore » PET data using population-based Bayesian parameters to construct predicted MPPs. Therapy simulations were performed as 30 min infusion of {sup 90}Y-DOTATATE of 3.3 GBq in both true and predicted MPPs. Prediction accuracy was then calculated as relative variability v{sub organ} between TIACs from both MPPs. Results: Large variability values of one time-point protocols [e.g., FSD = 1%, 240 min p.i., v{sub kidneys} = (9 ± 6)%, and v{sub tumor} = (27 ± 26)%] show inaccurate prediction. Accurate TIAC prediction of the kidneys was obtained for the case of two measurements (1 and 4 h p.i.), e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 10)%, or three measurements, e.g., FSD = 1%, v{sub kidneys} = (7 ± 3)%, and v{sub tumor} = (22 ± 9)%. Conclusions: {sup 68}Ga-DOTATATE-PET measurements could possibly be used to predict the TIACs of {sup 90}Y-DOTATATE when using a PBPK model and population-based Bayesian parameters. The two time-point measurement at 1 and 4 h p.i. with a noise up to FSD = 1% allows an accurate prediction of the TIACs in kidneys.« less

  13. Doses and risks from the ingestion of Dounreay fuel fragments.

    PubMed

    Darley, P J; Charles, M W; Fell, T P; Harrison, J D

    2003-01-01

    The radiological implications of ingestion of nuclear fuel fragments present in the marine environment around Dounreay have been reassessed by using the Monte Carlo code MCNP to obtain improved estimates of the doses to target cells in the walls of the lower large intestine resulting from the passage of a fragment. The approach takes account of the reduction in dose due to attenuation within the intestinal wall and self-absorption of radiation in the fuel fragment itself. In addition, dose is calculated on the basis of a realistic estimate of the anatomical volume of the lumen, rather than being based on the average mass of the contents, as in the current ICRP model. Our best estimates of doses from the ingestion of the largest Dounreay particles are at least a factor of 30 lower than those predicted using the current ICRP model. The new ICRP model will address the issues raised here and provide improved estimates of dose.

  14. ASSESSING INTERNAL CONTAMINATION AFTER THE DETONATION OF A RADIOLOGICAL DISPERSION DEVICE USING A 2×2-INCH SODIUM IODIDE DETECTOR

    PubMed Central

    Dewji, S.; Hertel, N.; Ansari, A.

    2017-01-01

    The detonation of a radiological dispersion device may result in a situation where individuals inhale radioactive materials and require rapid assessment of internal contamination. The feasibility of using a 2×2-inch sodium-iodide detector to determine the committed effective dose to an individual following acute inhalation of gamma-emitting radionuclides was investigated. Experimental configurations of point sources with a polymethyl methacrylate slab phantom were used to validate Monte Carlo simulations. The validated detector model was used to simulate the responses for four detector positions on six different anthropomorphic phantoms. The nuclides examined included 241Am, 60Co, 137Cs, 131I and 192Ir. Biokinetic modelling was employed to determine the distributed activity in the body as a function of post-inhalation time. The simulation and biokinetic data were used to determine time-dependent count-rate values at optimal detector locations on the body for each radionuclide corresponding to a target committed effective dose (E50) value of 250 mSv. PMID:23436621

  15. Modelling of microalgal growth and lipid production in Dunaliella tertiolecta using nitrogen-phosphorus-potassium fertilizer medium in sintered disk chromatographic glass bubble column.

    PubMed

    Kumar, Anup; Guria, Chandan; Chitres, G; Chakraborty, Arunangshu; Pathak, A K

    2016-10-01

    A comprehensive mathematical model involving NPK-10:26:26 fertilizer, NaCl, NaHCO3, light and temperature operating variables for Dunaliella tertiolecta cultivation is formulated to predict microalgae-biomass and lipid productivity. Proposed model includes Monod/Andrews kinetics for the absorption of essential nutrients into algae-biomass and Droop model involving internal nutrient cell quota for microalgae growth, assuming algae-biomass is composed of sugar, functional-pool and neutral-lipid. Biokinetic model parameters are determined by minimizing the residual-sum-of-square-errors between experimental and computed microalgae-biomass and lipid productivity using genetic algorithm. Developed model is validated with the experiments of Dunaliella tertiolecta cultivation using air-agitated sintered-disk chromatographic glass-bubble column and the effects of operating variables on microalgae-biomass and lipid productivity is investigated. Finally, parametric sensitivity analysis is carried out to know the sensitivity of model parameters on the obtained results in the input parameter space. Proposed model may be helpful in scale-up studies and implementation of model-based control strategy in large-scale algal cultivation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. ANIMAL MODELS: CARDIOVASCULAR DISEASE, CNS INJURY AND ULTRAFINE PARTICLE BIOKINETICS

    EPA Science Inventory

    The Animal Core studies will help to answer the question of why subpopulations are at increased risk of adverse health outcomes following PM exposure. They will identify the cellular and molecular mechanisms which underlie cardiovascular susceptibility. Exposure-response rel...

  17. Ustur whole body case 0269: demonstrating effectiveness of i.v. CA-DTPA for Pu.

    PubMed

    James, A C; Sasser, L B; Stuit, D B; Glover, S E; Carbaugh, E H

    2007-01-01

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO3)4 solution in the form of an aerosol 'mist'. Chelation treatment with intravenously (i.v.) Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2.5 y with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of 239+240Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation) and continuing for 37 y. This sampling included all intervals of chelation. In addition, 91 measurements of 239+240Pu-in-feces were recorded over this whole period. The Registrant died about 38 y after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their 238Pu, 239+240Pu and 241Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive data set has been applied to derive 'chelation-enhanced' transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are approximately 40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys and 50% for the skeleton. Essentially, all of the substantial reduction in skeletal burden occurred in trabecular bone. This modelling exercise demonstrated that 3-y-delayed Ca-DTPA therapy was as effective

  18. USTUR WHOLE BODY CASE 0269: DEMONSTRATING EFFECTIVENESS OF I.V. CA-DTPA FOR PU

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Anthony C.; Sasser , Lyle B.; Stuit, Dorothy B.

    2008-01-28

    This whole body donation case (USTUR Registrant) involved a single acute inhalation of an acidic Pu(NO3)4 solution in the form of an aerosol ‘mist.’ Chelation treatment with i.v. Ca-EDTA was initiated on the day of the intake, and continued intermittently over 6 months. After 2½ years with no further treatment, a course of i.v. Ca-DTPA was administered. A total of 400 measurements of 239+240Pu excreted in urine were recorded; starting on the first day (both before and during the initial Ca-EDTA chelation), and continuing for 37 years. This sampling included all intervals of chelation. In addition, 91 measurements of 239+240Pu-in-fecesmore » were recorded over this whole period. The Registrant died about 38 years after the intake, at age 79 y, with extensive carcinomatosis secondary to adenocarcinoma of the prostate gland. At autopsy, all major soft tissue organs were harvested for radiochemical analyses of their 238Pu, 239+240Pu and 241Am content. Also, all types of bone (comprising about half the skeleton) were harvested for radiochemical analyses, as well as samples of skin, subcutaneous fat and muscle. This comprehensive dataset has been applied to derive ‘chelation-enhanced’ transfer rates in the ICRP Publication 67 plutonium biokinetic model, representing the behaviour of blood-borne and tissue-incorporated plutonium during intervals of therapy. The resulting model of the separate effects of i.v. Ca-EDTA and Ca-DTPA chelation shows that the therapy administered in this case succeeded in reducing substantially the long-term burden of plutonium in all body organs, except for the lungs. The calculated reductions in organ content at the time of death are approximately 40% for the liver, 60% for other soft tissues (muscle, skin, glands, etc.), 50% for the kidneys, and 50% for the skeleton. Essentially all of the substantial reduction in skeletal burden occurred in trabecular bone. This modeling exercise demonstrated that 3-y-delayed Ca-DTPA therapy was

  19. KDEP: A resource for calculating particle deposition in the respiratory tract

    DOE PAGES

    Klumpp, John A.; Bertelli, Luiz

    2017-08-01

    This study presents KDEP, an open-source implementation of the ICRP lung deposition model developed by the authors. KDEP, which is freely available to the public, can be used to calculate lung deposition values under a variety of different conditions using the ICRP methodology. The paper describes how KDEP implements this model and discusses some key points of the implementation. The published lung deposition values for intakes by workers were reproduced, and new deposition values were calculated for intakes by members of the public. KDEP can be obtained for free at github.com or by emailing the authors directly.

  20. Technical Evaluation of the NASA Model for Cancer Risk to Astronauts Due to Space Radiation

    NASA Technical Reports Server (NTRS)

    2012-01-01

    At the request of NASA, the National Research Council's (NRC's) Committee for Evaluation of Space Radiation Cancer Risk Model reviewed a number of changes that NASA proposes to make to its model for estimating the risk of radiation-induced cancer in astronauts. The NASA model in current use was last updated in 2005, and the proposed model would incorporate recent research directed at improving the quantification and understanding of the health risks posed by the space radiation environment. NASA's proposed model is defined by the 2011 NASA report Space Radiation Cancer Risk Projections and Uncertainties 2010 (Cucinotta et al., 2011). The committee's evaluation is based primarily on this source, which is referred to hereafter as the 2011 NASA report, with mention of specific sections or tables cited more formally as Cucinotta et al. (2011). The overall process for estimating cancer risks due to low linear energy transfer (LET) radiation exposure has been fully described in reports by a number of organizations. They include, more recently: (1) The "BEIR VII Phase 2" report from the NRC's Committee on Biological Effects of Ionizing Radiation (BEIR) (NRC, 2006); (2) Studies of Radiation and Cancer from the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2006), (3) The 2007 Recommendations of the International Commission on Radiological Protection (ICRP), ICRP Publication 103 (ICRP, 2007); and (4) The Environmental Protection Agency s (EPA s) report EPA Radiogenic Cancer Risk Models and Projections for the U.S. Population (EPA, 2011). The approaches described in the reports from all of these expert groups are quite similar. NASA's proposed space radiation cancer risk assessment model calculates, as its main output, age- and gender-specific risk of exposure-induced death (REID) for use in the estimation of mission and astronaut-specific cancer risk. The model also calculates the associated uncertainties in REID. The general approach for

  1. Evaluation of the intake of radon through skin from thermal water.

    PubMed

    Sakoda, Akihiro; Ishimori, Yuu; Tschiersch, Jochen

    2016-07-01

    The biokinetics of radon in the body has previously been studied with the assumption that its absorption through the skin is negligibly small. This assumption would be acceptable except in specific situations, such as bathing in a radon hot spring where the radon concentration in thermal water is far higher than that in air. The present study focused on such a situation in order to better understand the biokinetics of radon. To mathematically express the entry of radon through the skin into the body, we first modified the latest sophisticated biokinetic model for noble gases. Values of an important parameter for the model-the skin permeability coefficient K (m s(-1))-were derived using data from previous human studies. The analysis of such empirical data, which corresponded to radon concentrations in the air exhaled by subjects during and following bathing in radon-rich thermal water, revealed that the estimated K values had a log-normal distribution. The validity of the K values and the characteristics of the present model are then discussed. Furthermore, the impact of the intake of radon or its progeny via inhalation or skin absorption on radiation dose was also assessed for possible exposure scenarios in a radon hot spring. It was concluded that, depending on the radon concentration in thermal water, there might be situations in which the dose contribution resulting from skin absorption of radon is comparable to that resulting from inhalation of radon and its progeny. This conclusion can also apply to other therapeutic situations (e.g. staying in the pool for a longer period). © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  2. Bioavailability and toxicity of trace metals to the cladoceran Daphnia magna in relation to cadmium exposure history

    NASA Astrophysics Data System (ADS)

    Guan, Rui

    The cladoceran Daphnia magna is widely used in freshwater bioassessments and ecological risk assessments. This study designed a series of experiments employing radiotracer methodology to quantify the trace metals (mainly Cd and Zn) biokinetics in D. magna under different environmental and biological conditions and to investigate the influences of different Cd exposure histories on the bioavailability and toxicity of trace metals to D. magna. A bioenergetic-based kinetic model was finally applied in predicting the Cd accumulation dynamics in D. magna and the model validity under non-steady state was assessed. Cd assimilation was found in this study to be influenced by the food characteristics (e.g., metal concentration in food particles), the metal exposure history of the animals, and the genetic characteristics. Some of these influences could be interpreted by the capacity and/or competition of those metal binding sites within the digestive tract and/or the detoxifying proteins metallothionein (MT). My study demonstrated a significant induction of MT in response to Cd exposure and it was the dominant fraction in sequestering the internal nonessential trace metals in D. magna. The ratio of Cd body burden to MT might better predict the Cd toxicity on the digestion systems of D. magna than the Cd tissue burden alone within one-generational exposure to Cd. It was found that metal elimination (rate constant and contribution of different release routes) was independent of the food concentration and the dietary metal concentration, implying that the elimination may not be metabolically controlled. The incorporation of the bioenergetic-based kinetic model, especially under non-steady state, is invaluable in helping to understand the fate of trace metals in aquatic systems and potential environmental risks. The dependence of biokinetic parameters on environmental factors rather than on genotypes implies a great potential of using biokinetics in inter-laboratory comparisons.

  3. Evaluation of the information content of long-term wastewater characteristics data in relation to activated sludge model parameters.

    PubMed

    Alikhani, Jamal; Takacs, Imre; Al-Omari, Ahmed; Murthy, Sudhir; Massoudieh, Arash

    2017-03-01

    A parameter estimation framework was used to evaluate the ability of observed data from a full-scale nitrification-denitrification bioreactor to reduce the uncertainty associated with the bio-kinetic and stoichiometric parameters of an activated sludge model (ASM). Samples collected over a period of 150 days from the effluent as well as from the reactor tanks were used. A hybrid genetic algorithm and Bayesian inference were used to perform deterministic and parameter estimations, respectively. The main goal was to assess the ability of the data to obtain reliable parameter estimates for a modified version of the ASM. The modified ASM model includes methylotrophic processes which play the main role in methanol-fed denitrification. Sensitivity analysis was also used to explain the ability of the data to provide information about each of the parameters. The results showed that the uncertainty in the estimates of the most sensitive parameters (including growth rate, decay rate, and yield coefficients) decreased with respect to the prior information.

  4. Implications of human tissue studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.

    1986-10-01

    Through radiochemical analysis of voluntary tissue donations, the United States Transuranium and Uranium Registries are gaining improved understanding of the distribution and biokinetics of actinide elements in occupationally exposed persons. Evaluation of the first two whole body contributions to the Transuranium Registry revealed an inverse proportionality between actinide concentration and bone ash fraction. The analysis of a whole body with a documented /sup 241/Am deposition indicated a significantly shorter half-time in liver and a greater fraction resident in the skeleton than predicted by existing models. Other studies of the Registries are designed to evaluate in vivo estimates of actinide depositionmore » with those derived from postmortem tissue analysis, compare results of animal experiments with human data, and reviw histopathologic slides for tissue toxicity that might be attributable to exposure to uranium and the transuranic elements. The implications of these recent findings and other work of the Registries are discussed from the standpoint of their potential impact on biokinetic modeling, internal dose assessment, safety standards, and operational health physics practices.« less

  5. Organ dose calculations by Monte Carlo modeling of the updated VCH adult male phantom against idealized external proton exposure

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Liu, Qian; Zeng, Shaoqun; Luo, Qingming

    2008-07-01

    The voxel-based visible Chinese human (VCH) adult male phantom has offered a high-quality test bed for realistic Monte Carlo modeling in radiological dosimetry simulations. The phantom has been updated in recent effort by adding newly segmented organs, revising walled and smaller structures as well as recalibrating skeletal marrow distributions. The organ absorbed dose against external proton exposure was calculated at a voxel resolution of 2 × 2 × 2 mm3 using the MCNPX code for incident energies from 20 MeV to 10 GeV and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO), respectively. The effective dose on the VCH phantom was derived in compliance with the evaluation scheme for the reference male proposed in the 2007 recommendations of the International Commission on Radiological Protection (ICRP). Algorithm transitions from the revised radiation and tissue weighting factors are accountable for approximately 90% and 10% of effective dose discrepancies in proton dosimetry, respectively. Results are tabulated in terms of fluence-to-dose conversion coefficients for practical use and are compared with data from other models available in the literature. Anatomical variations between various computational phantoms lead to dose discrepancies ranging from a negligible level to 100% or more at proton energies below 200 MeV, corresponding to the spatial geometric locations of individual organs within the body. Doses show better agreement at higher energies and the deviations are mostly within 20%, to which the organ volume and mass differences should be of primary responsibility. The impact of body size on dose distributions was assessed by dosimetry of a scaled-up VCH phantom that was resized in accordance with the height and total mass of the ICRP reference man. The organ dose decreases with the directionally uniform enlargement of voxels. Potential

  6. Risks to children from exposure to lead in air during remedial or removal activities at Superfund sites: a case study of the RSR lead smelter Superfund site.

    PubMed

    Khoury, Ghassan A; Diamond, Gary L

    2003-01-01

    Superfund sites that are contaminated with lead and undergoing remedial action generate lead-enriched dust that can be released into the air. Activities that can emit lead-enriched dust include demolition of lead smelter buildings, stacks, and baghouses; on-site traffic of heavy construction vehicles; and excavation of soil. Typically, air monitoring stations are placed around the perimeter of a site of an ongoing remediation to monitor air lead concentrations that might result from site emissions. The National Ambient Air Quality (NAAQ) standard, established in 1978 to be a quarterly average of 1.5 microg/m(3), is often used as a trigger level for corrective action to reduce emissions. This study explored modeling approaches for assessing potential risks to children from air lead emissions from the RSR Superfund site in West Dallas, TX, during demolition and removal of a smelter facility. The EPA Integrated Exposure Uptake Biokinetic (IEUBK) model and the International Commission of Radiologic Protection (ICRP) lead model were used to simulate blood lead concentrations in children, based on monitored air lead concentrations. Although air lead concentrations at monitoring stations located in the downwind community intermittently exceeded the NAAQ standard, both models indicated that exposures to children in the community areas did not pose a significant long-term or acute risk. Long-term risk was defined as greater than 5% probability of a child having a long-term blood lead concentration that exceeded 10 microg/dl, which is the CDC and the EPA blood lead concern level. Short-term or acute risk was defined as greater than 5% probability of a child having a blood lead concentration on any given day that exceeded 20 microg/dl, which is the CDC trigger level for medical evaluation (this is not intended to imply that 20 microg/dl is a threshold for health effects in children exposed acutely to airborne lead). The estimated potential long-term and short-term exposures

  7. Dynamic modeling of nitrogen removal for a three-stage integrated fixed-film activated sludge process treating municipal wastewater.

    PubMed

    Moretti, Paul; Choubert, Jean-Marc; Canler, Jean-Pierre; Buffière, Pierre; Pétrimaux, Olivier; Lessard, Paul

    2018-02-01

    The integrated fixed-film activated sludge (IFAS) process is being increasingly used to enhance nitrogen removal for former activated sludge systems. The aim of this work is to evaluate a numerical model of a new nitrifying/denitrifying IFAS configuration. It consists of two carrier-free reactors (anoxic and aerobic) and one IFAS reactor with a filling ratio of 43% of carriers, followed by a clarifier. Simulations were carried out with GPS-X involving the nitrification reaction combined with a 1D heterogeneous biofilm model, including attachment/detachment processes. An original iterative calibration protocol was created comprising four steps and nine actions. Experimental campaigns were carried out to collect data on the pilot in operation, specifically for modelling purpose. The model used was able to predict properly the variations of the activated sludge (bulk) and the biofilm masses, the nitrification rates of both the activated sludge and the biofilm, and the nitrogen concentration in the effluent for short (4-10 days) and long (300 days) simulation runs. A calibrated parameter set is proposed (biokinetics, detachment, diffusion) related to the activated sludge, the biofilm and the effluent variables to enhance the model prediction on hourly and daily data sets.

  8. Evaluation of the intake of radon through skin from thermal water

    PubMed Central

    Sakoda, Akihiro; Ishimori, Yuu; Tschiersch, Jochen

    2016-01-01

    The biokinetics of radon in the body has previously been studied with the assumption that its absorption through the skin is negligibly small. This assumption would be acceptable except in specific situations, such as bathing in a radon hot spring where the radon concentration in thermal water is far higher than that in air. The present study focused on such a situation in order to better understand the biokinetics of radon. To mathematically express the entry of radon through the skin into the body, we first modified the latest sophisticated biokinetic model for noble gases. Values of an important parameter for the model—the skin permeability coefficient K (m s−1)—were derived using data from previous human studies. The analysis of such empirical data, which corresponded to radon concentrations in the air exhaled by subjects during and following bathing in radon-rich thermal water, revealed that the estimated K values had a log-normal distribution. The validity of the K values and the characteristics of the present model are then discussed. Furthermore, the impact of the intake of radon or its progeny via inhalation or skin absorption on radiation dose was also assessed for possible exposure scenarios in a radon hot spring. It was concluded that, depending on the radon concentration in thermal water, there might be situations in which the dose contribution resulting from skin absorption of radon is comparable to that resulting from inhalation of radon and its progeny. This conclusion can also apply to other therapeutic situations (e.g. staying in the pool for a longer period). PMID:26983980

  9. SU-E-J-93: Development of Pre-Contoured Human Model Library in DICOM-RT Format for the Epidemiological Study of the Radiotherapy Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyakuryal, A; Lee, C; Lee, C

    Purpose: Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D beams-eye-view from the conventional simulator. To analyze the outcomes of such treatments for radiation late effects, 3D computational human models are often used in commercial treatment planning systems (TPSs). However, several underlying difficulties such as time-consuming manual delineation procedures of a large number of structures in the model have always limited its applications. Primary objective of this work was to develop a human model library for the epidemiological study by converting 3D-surface model organs to DICOM-RT format (DICOM-RT structure) using an in-house built software.more » We converted the ICRP reference human models to DICOM-RT models, which can be readily adopted for various dose calculations. Methods: MATLAB based code were utilized to convert the contour drawings extracted in text-format from the 3D graphic-tool, Rhinoceros into DICOM-RT structure format for 50 different organs of each model using a 16GB dual-core processor. The conversion periods were measured for each DICOM-RT models, and the reconstructed structure volumes were validated against the original 3D-surface models in the TPS. Ten reference hybrid whole-body models (8-pediatric and 2-adults) were automatically processed to create DICOM-RT computational human model library. Results: Mean contour conversion period was found to be 580 (N=2) and 394.5 (N=8) seconds for 50 organs in the adult and pediatric models respectively. A good agreement for large organs (NRMSD <1.0%) and small organs (NRMSD <7.7%) was also observed between the original volumes and corresponding DICOM-RT structure volumes of the organs. Conclusion: The ICRP reference human models were converted into DICOM-RT format to support the epidemiological study using a large cohort of conventional radiotherapy patients. Due to its DICOM-compatibility, the library may be implemented to many other

  10. Assessment of uncertainties in the lung activity measurement of low-energy photon emitters using Monte Carlo simulation of ICRP male thorax voxel phantom.

    PubMed

    Nadar, M Y; Akar, D K; Rao, D D; Kulkarni, M S; Pradeepkumar, K S

    2015-12-01

    Assessment of intake due to long-lived actinides by inhalation pathway is carried out by lung monitoring of the radiation workers inside totally shielded steel room using sensitive detection systems such as Phoswich and an array of HPGe detectors. In this paper, uncertainties in the lung activity estimation due to positional errors, chest wall thickness (CWT) and detector background variation are evaluated. First, calibration factors (CFs) of Phoswich and an array of three HPGe detectors are estimated by incorporating ICRP male thorax voxel phantom and detectors in Monte Carlo code 'FLUKA'. CFs are estimated for the uniform source distribution in lungs of the phantom for various photon energies. The variation in the CFs for positional errors of ±0.5, 1 and 1.5 cm in horizontal and vertical direction along the chest are studied. The positional errors are also evaluated by resizing the voxel phantom. Combined uncertainties are estimated at different energies using the uncertainties due to CWT, detector positioning, detector background variation of an uncontaminated adult person and counting statistics in the form of scattering factors (SFs). SFs are found to decrease with increase in energy. With HPGe array, highest SF of 1.84 is found at 18 keV. It reduces to 1.36 at 238 keV. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Deterministic Models of Inhalational Anthrax in New Zealand White Rabbits

    PubMed Central

    2014-01-01

    Computational models describing bacterial kinetics were developed for inhalational anthrax in New Zealand white (NZW) rabbits following inhalation of Ames strain B. anthracis. The data used to parameterize the models included bacterial numbers in the airways, lung tissue, draining lymph nodes, and blood. Initial bacterial numbers were deposited spore dose. The first model was a single exponential ordinary differential equation (ODE) with 3 rate parameters that described mucociliated (physical) clearance, immune clearance (bacterial killing), and bacterial growth. At 36 hours postexposure, the ODE model predicted 1.7×107 bacteria in the rabbit, which agreed well with data from actual experiments (4.0×107 bacteria at 36 hours). Next, building on the single ODE model, a physiological-based biokinetic (PBBK) compartmentalized model was developed in which 1 physiological compartment was the lumen of the airways and the other was the rabbit body (lung tissue, lymph nodes, blood). The 2 compartments were connected with a parameter describing transport of bacteria from the airways into the body. The PBBK model predicted 4.9×107 bacteria in the body at 36 hours, and by 45 hours the model showed all clearance mechanisms were saturated, suggesting the rabbit would quickly succumb to the infection. As with the ODE model, the PBBK model results agreed well with laboratory observations. These data are discussed along with the need for and potential application of the models in risk assessment, drug development, and as a general aid to the experimentalist studying inhalational anthrax. PMID:24527843

  12. Compartmental model of 18F-choline

    NASA Astrophysics Data System (ADS)

    Janzen, T.; Tavola, F.; Giussani, A.; Cantone, M. C.; Uusijärvi, H.; Mattsson, S.; Zankl, M.; Petoussi-Henß, N.; Hoeschen, C.

    2010-03-01

    The MADEIRA Project (Minimizing Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations), aims to improve the efficacy and safety of 3D functional imaging by optimizing, among others, the knowledge of the temporal variation of the radiopharmaceuticals' uptake in and clearance from tumor and healthy tissues. With the help of compartmental modeling it is intended to optimize the time schedule for data collection and improve the evaluation of the organ doses to the patients. Administration of 18F-choline to screen for recurrence or the occurrence of metastases in prostate cancer patients is one of the diagnostic applications under consideration in the frame of the project. PET and CT images have been acquired up to four hours after injection of 18F-choline. Additionally blood and urine samples have been collected and measured in a gamma counter. The radioactivity concentration in different organs and data of plasma clearance and elimination into urine were used to set-up a compartmental model of the biokinetics of the radiopharmaceutical. It features a central compartment (blood) exchanging with organs. The structure describes explicitly liver, kidneys, spleen, plasma and bladder as separate units with a forcing function approach. The model is presented together with an evaluation of the individual and population kinetic parameters, and a revised time schedule for data collection is proposed. This optimized time schedule will be validated in a further set of patient studies.

  13. CFD-aided modelling of activated sludge systems - A critical review.

    PubMed

    Karpinska, Anna M; Bridgeman, John

    2016-01-01

    Nowadays, one of the major challenges in the wastewater sector is the successful design and reliable operation of treatment processes, which guarantee high treatment efficiencies to comply with effluent quality criteria, while keeping the investment and operating cost as low as possible. Although conceptual design and process control of activated sludge plants are key to ensuring these goals, they are still based on general empirical guidelines and operators' experience, dominated often by rule of thumb. This review paper discusses the rationale behind the use of Computational Fluid Dynamics (CFD) to model aeration, facilitating enhancement of treatment efficiency and reduction of energy input. Several single- and multiphase approaches commonly used in CFD studies of aeration tank operation, are comprehensively described, whilst the shortcomings of the modelling assumptions imposed to evaluate mixing and mass transfer in AS tanks are identified and discussed. Examples and methods of coupling of CFD data with biokinetics, accounting for the actual flow field and its impact on the oxygen mass transfer and yield of the biological processes occurring in the aeration tanks, are also critically discussed. Finally, modelling issues, which remain unaddressed, (e.g. coupling of the AS tank with secondary clarifier and the use of population balance models to simulate bubbly flow or flocculation of the activated sludge), are also identified and discussed. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry.

    PubMed

    Garcia, Marie-Paule; Villoing, Daphnée; McKay, Erin; Ferrer, Ludovic; Cremonesi, Marta; Botta, Francesca; Ferrari, Mahila; Bardiès, Manuel

    2015-12-01

    The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit gate offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on gate to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user's imaging requirements and generates automatically command files used as input for gate. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant gate input files are generated for the virtual patient model and associated pharmacokinetics. Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body "step and shoot" acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110

  15. Activated sludge model (ASM) based modelling of membrane bioreactor (MBR) processes: a critical review with special regard to MBR specificities.

    PubMed

    Fenu, A; Guglielmi, G; Jimenez, J; Spèrandio, M; Saroj, D; Lesjean, B; Brepols, C; Thoeye, C; Nopens, I

    2010-08-01

    Membrane bioreactors (MBRs) have been increasingly employed for municipal and industrial wastewater treatment in the last decade. The efforts for modelling of such wastewater treatment systems have always targeted either the biological processes (treatment quality target) as well as the various aspects of engineering (cost effective design and operation). The development of Activated Sludge Models (ASM) was an important evolution in the modelling of Conventional Activated Sludge (CAS) processes and their use is now very well established. However, although they were initially developed to describe CAS processes, they have simply been transferred and applied to MBR processes. Recent studies on MBR biological processes have reported several crucial specificities: medium to very high sludge retention times, high mixed liquor concentration, accumulation of soluble microbial products (SMP) rejected by the membrane filtration step, and high aeration rates for scouring purposes. These aspects raise the question as to what extent the ASM framework is applicable to MBR processes. Several studies highlighting some of the aforementioned issues are scattered through the literature. Hence, through a concise and structured overview of the past developments and current state-of-the-art in biological modelling of MBR, this review explores ASM-based modelling applied to MBR processes. The work aims to synthesize previous studies and differentiates between unmodified and modified applications of ASM to MBR. Particular emphasis is placed on influent fractionation, biokinetics, and soluble microbial products (SMPs)/exo-polymeric substances (EPS) modelling, and suggestions are put forward as to good modelling practice with regard to MBR modelling both for end-users and academia. A last section highlights shortcomings and future needs for improved biological modelling of MBR processes. (c) 2010 Elsevier Ltd. All rights reserved.

  16. In Vivo Chemoprotective Activity of Bovine Dialyzable Leukocyte Extract in Mouse Bone Marrow Cells against Damage Induced by 5-Fluorouracil

    PubMed Central

    Coronado-Cerda, Erika Evangelina; Franco-Molina, Moisés Armides; Mendoza-Gamboa, Edgar; Prado-García, Heriberto; Rivera-Morales, Lydia Guadalupe; Zapata-Benavides, Pablo; Rodríguez-Salazar, María del Carmen; Caballero-Hernandez, Diana; Tamez-Guerra, Reyes Silvestre; Rodríguez-Padilla, Cristina

    2016-01-01

    Chemotherapy treatments induce a number of side effects, such as leukopenia neutropenia, peripheral erythropenia, and thrombocytopenia, affecting the quality of life for cancer patients. 5-Fluorouracil (5-FU) is wieldy used as myeloablative model in mice. The bovine dialyzable leukocyte extract (bDLE) or IMMUNEPOTENT CRP® (ICRP) is an immunomodulatory compound that has antioxidants and anti-inflammatory effects. In order to investigate the chemoprotection effect of ICRP on bone marrow cells in 5-FU treated mice, total bone marrow (BM) cell count, bone marrow colony forming units-granulocyte/macrophage (CFU-GM), cell cycle, immunophenotypification, ROS/superoxide and Nrf2 by flow cytometry, and histological and hematological analyses were performed. Our results demonstrated that ICRP increased BM cell count and CFU-GM number, arrested BM cells in G0/G1 phase, increased the percentage of leukocyte, granulocytic, and erythroid populations, reduced ROS/superoxide formation and Nrf2 activation, and also improved hematological levels and weight gain in 5-FU treated mice. These results suggest that ICRP has a chemoprotective effect against 5-FU in BM cells that can be used in cancer patients. PMID:27191003

  17. Estimation of whole-body radiation exposure from brachytherapy for oral cancer using a Monte Carlo simulation

    PubMed Central

    Ozaki, Y.; Kaida, A.; Miura, M.; Nakagawa, K.; Toda, K.; Yoshimura, R.; Sumi, Y.; Kurabayashi, T.

    2017-01-01

    Abstract Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. PMID:28339846

  18. 18F-FPEB, a PET radiopharmaceutical for quantifying metabotropic glutamate 5 receptors: a first-in-human study of radiochemical safety, biokinetics, and radiation dosimetry.

    PubMed

    Wong, Dean F; Waterhouse, Rikki; Kuwabara, Hiroto; Kim, Jongho; Brašić, James R; Chamroonrat, Wichana; Stabins, Michael; Holt, Daniel P; Dannals, Robert F; Hamill, Terence G; Mozley, P David

    2013-03-01

    Identification of safe and valid PET radioligands for metabotropic glutamate receptor, type 5 (mGluR5), is essential to measure changes in brain mGluR5 in neuropsychiatric disorders, to confirm central mGluR5 occupancy of drug candidates, and to guide dose selection for obtaining an optimum therapeutic window. Here we present the results of a first-in-human study assessing the safety and effectiveness of a novel PET radiopharmaceutical, (18)F-3-fluoro-5-[(pyridin-3-yl)ethynyl]benzonitrile ((18)F-FPEB), for quantifying regional brain concentrations of mGluR5. Quantification of whole-body biokinetics was conducted in 6 healthy adults (3 men and 3 women). The radiation safety profile was estimated with OLINDA/EXM software. Subsequently, pairs of dynamic brain scans were obtained for 11 healthy men to identify optimal methods for derivation of regional distribution volume and binding potential and to determine the repeatability of measurement. The whole-body effective radiation dose was approximately 17 μSv/MBq (62 mrem/mCi), with the gallbladder receiving the highest dose of 190 μSv/MBq. In brain studies, time-activity curves showed high accumulation in the insula/caudate nucleus, moderate uptake in the thalamus, and the lowest concentration in the cerebellum/pons. The plasma reference graphical analysis method appeared optimal for (18)F-FPEB; it showed acceptable test-retest variability of nondisplaceable binding potential (<10%) and identified the highest nondisplaceable binding potential values (from ∼0.5 in the globus pallidus to ∼3.5 in the insula) for target regions. Safety assessments revealed no clinically meaningful changes in vital signs, electrocardiogram, or laboratory values. (18)F-FPEB is safe and well tolerated, and its regional cerebral distribution is consistent with previous reports in the literature for metabotropic glutamate receptors. The repeatability of measurement suggests that (18)F-FPEB is suitable for quantifying mGluR5 in humans.

  19. Dosimetric assessment from 212Pb inhalation at a thorium purification plant.

    PubMed

    Campos, M P; Pecequilo, B R S

    2004-01-01

    At the Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, there is a facility (thorium purification plant) where materials with high thorium concentrations are manipulated. In order to estimate afterwards the lung cancer risk for the workers, the thoron daughter (212Pb) levels were assessed and the committed effective and lung committed equivalent doses for workers in place. A total of 28 air filter samples were measured by total alpha counting through the modified Kusnetz method, to determine the 212Pb concentraion. The committed effective dose and lung committed equivalent dose due to 212Pb inhalation were derived from compartmental analysis following the ICRP 66 lung compartmental model, and ICRP 67 lead metabolic model.

  20. Model-derived dose rates per unit concentration of radon in air in a generic plant geometry.

    PubMed

    Vives i Batlle, J; Smith, A; Vives-Lynch, S; Copplestone, D; Pröhl, G; Strand, T

    2011-11-01

    A model for the derivation of dose rates per unit radon concentration in plants was developed in line with the activities of a Task Group of the International Commission on Radiological Protection (ICRP), aimed at developing more realistic dosimetry for non-human biota. The model considers interception of the unattached and attached fractions of the airborne radon daughters by plant stomata, diffusion of radon gas through stomata, permeation through the plant's epidermis and translocation of deposited activity to plant interior. The endpoint of the model is the derivation of dose conversion coefficients relative to radon gas concentration at ground level. The model predicts that the main contributor to dose is deposition of (214)Po α-activity on the plant surface and that diffusion of radon daughters through the stomata is of relatively minor importance; hence, daily variations have a small effect on total dose.

  1. Biokinetic model-based multi-objective optimization of Dunaliella tertiolecta cultivation using elitist non-dominated sorting genetic algorithm with inheritance.

    PubMed

    Sinha, Snehal K; Kumar, Mithilesh; Guria, Chandan; Kumar, Anup; Banerjee, Chiranjib

    2017-10-01

    Algal model based multi-objective optimization using elitist non-dominated sorting genetic algorithm with inheritance was carried out for batch cultivation of Dunaliella tertiolecta using NPK-fertilizer. Optimization problems involving two- and three-objective functions were solved simultaneously. The objective functions are: maximization of algae-biomass and lipid productivity with minimization of cultivation time and cost. Time variant light intensity and temperature including NPK-fertilizer, NaCl and NaHCO 3 loadings are the important decision variables. Algal model involving Monod/Andrews adsorption kinetics and Droop model with internal nutrient cell quota was used for optimization studies. Sets of non-dominated (equally good) Pareto optimal solutions were obtained for the problems studied. It was observed that time variant optimal light intensity and temperature trajectories, including optimum NPK fertilizer, NaCl and NaHCO 3 concentration has significant influence to improve biomass and lipid productivity under minimum cultivation time and cost. Proposed optimization studies may be helpful to implement the control strategy in scale-up operation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Targeted imaging of gastrin-releasing peptide receptors with 99mTc-EDDA/HYNIC-[Lys3]-bombesin: biokinetics and dosimetry in women.

    PubMed

    Santos-Cuevas, Clara L; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Pichardo-Romero, Pablo A

    2008-08-01

    The gastrin-releasing peptide receptor (GRP-R) is expressed in several normal human tissues and is overexpressed in various human tumors including breast, prostate, small-cell lung cancer and pancreatic cancer. Recently, 99mTc-EDDA/HYNIC-[Lys]-bombesin (99mTc-HYNIC-BN) was reported as a radiopharmaceutical with high stability in human serum, specific cell GRP-R binding and rapid cell internalization. The aim of this study was to determine the biokinetics and dosimetry of 99mTc-HYNIC-BN and the feasibility of using this radiopharmaceutical to image GRP-R in four early breast cancer patients and seven healthy women. Whole-body images were acquired at 20, 90, 180 min, and 24 h after 99mTc-HYNIC-BN administration. The same regions of interest were drawn around source organs on each time frame and regions of interest were converted to activity (conjugate view counting method). The image sequence was used to extrapolate 99mTc-HYNIC-BN time-activity curves in each organ to calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. 99mTc-HYNIC-BN had a rapid blood clearance with mainly renal excretion. No statistically significant differences (P>0.05) in the radiation-absorbed doses among cancer patients and healthy women were observed. The average equivalent doses (n=11) were 24.8+/-8.8 mSv (kidneys), 7.3+/-1.8 mSv (lungs), 6.5+/-4.0 mSv (breast), 2.0+/-0.3 mSv (pancreas), 1.6+/-0.3 mSv (liver), 1.2+/-0.2 mSv (ovaries), and 1.0+/-0.2 mSv (red marrow). The effective dose was 3.3+/-0.6 mSv. The images showed well-differentiated concentration of 99mTc-HYNIC-BN in cancer mammary tissue. All the absorbed doses were comparable with those known for most of the 99mTc studies. 99mTc-HYNIC-BN shows high tumor uptake in breasts with malignant tumors so it is a promising imaging radiopharmaceutical to target site-specific early breast cancer. The results obtained

  3. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and whichmore » uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.« less

  4. Estimation of whole-body radiation exposure from brachytherapy for oral cancer using a Monte Carlo simulation.

    PubMed

    Ozaki, Y; Watanabe, H; Kaida, A; Miura, M; Nakagawa, K; Toda, K; Yoshimura, R; Sumi, Y; Kurabayashi, T

    2017-07-01

    Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  5. Adsorption and biodegradation of 2-chlorophenol by mixed culture using activated carbon as a supporting medium-reactor performance and model verification

    NASA Astrophysics Data System (ADS)

    Lin, Yen-Hui

    2017-11-01

    A non-steady-state mathematical model system for the kinetics of adsorption and biodegradation of 2-chlorophenol (2-CP) by attached and suspended biomass on activated carbon process was derived. The mechanisms in the model system included 2-CP adsorption by activated carbon, 2-CP mass transport diffusion in biofilm, and biodegradation by attached and suspended biomass. Batch kinetic tests were performed to determine surface diffusivity of 2-CP, adsorption parameters for 2-CP, and biokinetic parameters of biomass. Experiments were conducted using a biological activated carbon (BAC) reactor system with high recycled rate to approximate a completely mixed flow reactor for model verification. Concentration profiles of 2-CP by model predictions indicated that biofilm bioregenerated the activated carbon by lowering the 2-CP concentration at the biofilm-activated carbon interface as the biofilm grew thicker. The removal efficiency of 2-CP by biomass was approximately 98.5% when 2-CP concentration in the influent was around 190.5 mg L-1 at a steady-state condition. The concentration of suspended biomass reached up to about 25.3 mg L-1 while the thickness of attached biomass was estimated to be 636 μm at a steady-state condition by model prediction. The experimental results agree closely with the results of the model predictions.

  6. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J., E-mail: edwardc@schoolph.uma

    This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report'smore » Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.« less

  7. A case study of the long-term retention of 137Cs after inhalation of high temperature reactor fuel element ash.

    PubMed

    Froning, M; Kozielewski, T; Schläger, M; Hill, P

    2004-01-01

    In 1987, a worker was internally contaminated with 137Cs as a result of an accident during the handling of high temperature reactor fuel element ash. In the long-term follow-up monitoring an unusual retention behaviour was found. The observed time dependence of caesium retention does not agree with the standard models of ICRP Publication 30. The present case can be better explained by assuming an intake of a mixture of type F and type S compounds. However, experimental data can be best described by a four-exponential retention function with two long-lived components, which was used as an ad hoc model for dose calculation. The resulting dose is compared with doses calculated on the basis of ICRP Publication 66.

  8. TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, Marie-Paule, E-mail: marie-paule.garcia@univ-brest.fr; Villoing, Daphnée; McKay, Erin

    Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of amore » given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry

  9. US Transuranium and Uranium Registries case study on accidental exposure to uranium hexafluoride.

    PubMed

    Avtandilashvili, Maia; Puncher, Matthew; McComish, Stacey L; Tolmachev, Sergei Y

    2015-03-01

    The United States Transuranium and Uranium Registries' (USTUR) whole-body donor (Case 1031) was exposed to an acute inhalation of uranium hexafluoride (UF6) produced from an explosion at a uranium processing plant 65 years prior to his death. The USTUR measurements of tissue samples collected at the autopsy indicated long-term retention of inhaled slightly enriched uranium material (0.85% (235)U) in the deep lungs and thoracic lymph nodes. In the present study, the authors combined the tissue measurement results with historical bioassay data, and analysed them with International Commission on Radiological Protection (ICRP) respiratory tract models and the ICRP Publication 69 systemic model for uranium using maximum likelihood and Bayesian statistical methods. The purpose of the analysis was to estimate intakes and model parameter values that best describe the data, and evaluate their effect on dose assessment. The maximum likelihood analysis, which used the ICRP Publication 66 human respiratory tract model, resulted in a point estimate of 79 mg of uranium for the occupational intake composed of 86% soluble, type F material and 14% insoluble, type S material. For the Bayesian approach, the authors applied the Markov Chain Monte Carlo method, but this time used the revised human respiratory tract model, which is currently being used by ICRP to calculate new dose coefficients for workers. The Bayesian analysis estimated that the mean uranium intake was 160 mg, and calculated the case-specific lung dissolution parameters with their associated uncertainties. The parameters were consistent with the inhaled uranium material being predominantly soluble with a small but significant insoluble component. The 95% posterior range of the rapid dissolution fraction (the fraction of deposited material that is absorbed to blood rapidly) was 0.12 to 0.91 with a median of 0.37. The remaining fraction was absorbed slowly, with a 95% range of 0.000 22 d(-1) to 0.000 36

  10. Biofiltration kinetics for volatile organic compounds (VOCs) and development of a structure-biodegradability relationship

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Govind, R.; Wang, Z.; Bishop, D.F.

    1997-12-31

    In recent years, regulation of hazardous air pollutants under the Clean Air Act and its amendments, has emerged as a major environmental issue. Major sources of volatile organic compounds (VOCs) in air are chemical production plants, manufacturing sites using common solvents, combustion sources, and waste treatment operations, such as waste water treatment plants, vacuum extraction of contaminated soils, and ground water stripping operations. Biofiltration is an emerging technology for treatment of biodegradable volatile organic compounds (VOCs) present in air. In biofiltration, the contaminants are contacted with active microorganisms present either in naturally bioactive materials, such as soil, peat, compost, etc.,more » or immobilized on an inactive support media. Design of biofilters requires information on biodegradation kinetics which controls biofilter size. In this paper, an experimental microbiofilter system is presented which can be used to measure biofiltration kinetics for any volatile organic compound. A mathematical model is used to derive the Monod biokinetic parameters from the experimental data. Finally, a structure-bioactivity relationship is derived for estimating the biofiltration biokinetic parameters for a variety of VOCs.« less

  11. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Examples of Mesh and NURBS modelling for in vivo lung counting studies.

    PubMed

    Farah, Jad; Broggio, David; Franck, Didier

    2011-03-01

    Realistic calibration coefficients for in vivo counting installations are assessed using voxel phantoms and Monte Carlo calculations. However, voxel phantoms construction is time consuming and their flexibility extremely limited. This paper involves Mesh and non-uniform rational B-splines graphical formats, of greater flexibility, to optimise the calibration of in vivo counting installations. Two studies validating the use of such phantoms and involving geometry deformation and modelling were carried out to study the morphologic effect on lung counting efficiency. The created 3D models fitted with the reference ones, with volumetric differences of <5 %. Moreover, it was found that counting efficiency varies with the inverse of lungs' volume and that the latter primes when compared with chest wall thickness. Finally, a series of different thoracic female phantoms of various cup sizes, chest girths and internal organs' volumes were created starting from the International Commission on Radiological Protection (ICRP) adult female reference computational phantom to give correction factors for the lung monitoring of female workers.

  13. Comparison of fluence-to-dose conversion coefficients for deuterons, tritons and helions.

    PubMed

    Copeland, Kyle; Friedberg, Wallace; Sato, Tatsuhiko; Niita, Koji

    2012-02-01

    Secondary radiation in aircraft and spacecraft includes deuterons, tritons and helions. Two sets of fluence-to-effective dose conversion coefficients for isotropic exposure to these particles were compared: one used the particle and heavy ion transport code system (PHITS) radiation transport code coupled with the International Commission on Radiological Protection (ICRP) reference phantoms (PHITS-ICRP) and the other the Monte Carlo N-Particle eXtended (MCNPX) radiation transport code coupled with modified BodyBuilder™ phantoms (MCNPX-BB). Also, two sets of fluence-to-effective dose equivalent conversion coefficients calculated using the PHITS-ICRP combination were compared: one used quality factors based on linear energy transfer; the other used quality factors based on lineal energy (y). Finally, PHITS-ICRP effective dose coefficients were compared with PHITS-ICRP effective dose equivalent coefficients. The PHITS-ICRP and MCNPX-BB effective dose coefficients were similar, except at high energies, where MCNPX-BB coefficients were higher. For helions, at most energies effective dose coefficients were much greater than effective dose equivalent coefficients. For deuterons and tritons, coefficients were similar when their radiation weighting factor was set to 2.

  14. Evaluating the All-Ages Lead Model Using SiteSpecific Data ...

    EPA Pesticide Factsheets

    Lead (Pb) exposure continues to be a problem in the United States. Even after years of progress in reducing environmental levels, CDC estimates at least 500,000 U.S. children ages 1-5 years have blood Pb levels (BLL) above the CDC reference level of 5 µg/dL. Childhood Pb exposure is associated with neurological consequences and public health professionals continue to work to reduce Pb exposures. To better understand the relationship between exposure and BLL, the USEPA has developed a beta version of the All-Ages Lead Model (AALM). Compared to the Integrated Exposure Uptake Biokinetics (IEUBK) Model for lead in children, the AALM provides greater flexibility to describe Pb exposures (acute or chronic, constant or intermittent) for any age. At this time, the AALM has the capability to predict exposure in each of the following media: dust/soil, water, air, food, and other. As part of an interagency test group, we evaluated the ability of the AALM beta v4.2 (Leggett version) to predict BLLs for children that were exposed to Pb in their environment near the John T. Lewis and Bros Lead Smelter Superfund site. The model predicted that fourteen children met our inclusion criteria that spent less than 20 hours a week away from the home (e.g., no daycare or school) and had paired BLL and environmental sampling data (i.e., Pb in soil, window sill dust, front door dust, floor dust, and drinking water). The model can predict average BLLs, but it remains difficult to predic

  15. Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, P.A.

    1994-06-01

    Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and redmore » marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from tissue activities, ranged from 7-20 mSv y{sup {minus}1} using human weighting factors for comparison to human doses only. Effective doses to northern Canadians and wildlife were, respectively, 7-11% and 1.8-5 times an estimated human background of 4 mSv y{sup {minus}} from all sources. 51 refs., 2 figs., 9 tabs.« less

  16. Application of a canine 238Pu dosimetry model to human bioassay data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hickman, Jr., A. W.

    1991-08-01

    Associated with the use of 2 238Pu in thermoelectric power sources for space probes and power supplies for cardiac devices is the potential for human exposure to 238Pu, primarily by inhalation. In the event of human internal exposure, a means is needed for assessing the level of intake and calculating radiation doses. Several bioassay/dosimetry models have been developed for 239Pu. However, results from studies with laboratory animals have indicated that the biokinetics, and therefore the descriptive models, of 238Pu are significantly different from those for 239Pu. A canine model accounting for these differences has been applied in this work tomore » urinary excretion data from seven humans occupationally exposed to low levels of an insoluble 238Pu compound. The modified model provides a good description of the urinary excretion kinetics observed in the exposed humans. The modified model was also used to provide estimates of the initial intakes of 238Pu for the seven individuals; these estimates ranged from 4.5 nCi (170 Bq) to 87 nCi (3200 Bq). Autopsy data on the amount and distribution of 238Pu retained in the organs may be used in the future to validate or refute both these estimates and the assumptions used to formulate the human model. Modification of the human model to simulate an injection exposure to 239Pu gave patterns of retention in the organs and urinary excretion comparable to those seen previously in humans; further modification of the model using fecal data (unavailable for the subjects of this study) is indicated.« less

  17. Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers.

    PubMed

    Xie, Tianwu; Zaidi, Habib

    2016-12-01

    Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo/fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. We constructed eight embryo/fetus models at various gestation periods with 25 identified tissues according to reference data recommended by the ICRP publication 89 representing the anatomy of the developing embryo/fetus. The developed embryo/fetus models were integrated into realistic anthropomorphic computational phantoms of the pregnant female and used for estimating, using Monte Carlo calculations, S-values of common positron-emitting radionuclides, organ absorbed dose, and effective dose of a number of positron-emitting labeled radiotracers. The absorbed dose is nonuniformly distributed in the fetus. The absorbed dose of the kidney and liver of the 8-week-old fetus are about 47.45 % and 44.76 % higher than the average absorbed dose of the fetal total body for all investigated radiotracers. For 18 F-FDG, the fetal effective doses are 2.90E-02, 3.09E-02, 1.79E-02, 1.59E-02, 1.47E-02, 1.40E-02, 1.37E-02, and 1.27E-02 mSv/MBq at the 8th, 10th, 15th, 20th, 25th, 30th, 35th, and 38th weeks of gestation, respectively. The developed pregnant female/fetus models matching the ICRP reference data can be exploited by dedicated software packages for internal and external dose calculations. The generated S-values will be useful to produce new standardized dose estimates to pregnant patients and embryo/fetus from a variety of positron-emitting labeled radiotracers.

  18. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver

    NASA Astrophysics Data System (ADS)

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-01

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  19. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver.

    PubMed

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-21

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  20. Nutrients removal from artificial bathroom greywater using Botryococcus sp. strain

    NASA Astrophysics Data System (ADS)

    Mohamed, RMSR; Al-Gheethi, AA; Wurochekke, AA; Maizatul, AY; Matias-Peralta, HM; Kassim, AH Mohd

    2018-04-01

    The discharge of untreated bathroom greywater directly into drain is a most common practice in the rural area. The uncontrolled discharge of greywater from the village houses escalates the pollution among Malaysian river and provide insanitary environment through mosquito and flies breeding grounds. Therefore, the current work aimed to investigate the potential of Botryococcus sp. for removing total nitrogen (TN), total phosphorus (TP) and total organic carbon (TOC) from artificial bathroom greywater and to determine the bio-kinetic removal rate for these parameters. The artificial bathroom greywater was prepared by using regular brands used in the community, the bathroom greywater quality was tested for BOD, COD, SS, pH, and Turbidity. The removal process was conducted in the lab scale with 108 cell mL-1 of Botryococcus sp. The removal of TN, TP and TOC was measured in interval of 3, 5 and 7 days. The results deduced that Botryococcus sp. removed 51.5% of TN, 49.5% of TP and 42.6% of TOC. Moreover, the bio-kinetic model studies, revealed that the specific removal rate of TN, TP and TOC have a significant relationship with initial concentration in the artificial greywater (R2 = 0.63, 0.95 and 0.95 respectively). The kinetic coefficient of greywater parameters removed by Botryococcus sp. was determined as k=0.357 mg TN 1 log10 cell mL-1 d-1 and km=31.33 mg L-1 (R2=0.73), k=4.58 mg TP 1 log10 cell mL-1 d-1 and km=283.86 mg L-1 (R2=0.95), k=7.9 mg TOC 1 log10 cell mL-1 d-1 and km=322.32 mg L-1 (R2=0.97). The bio-kinetic model indicated that more than 90% of TN, TP and TOC was taken place as a response for Botryococcus sp.

  1. Application of the IEUBK model for linking Children's blood lead with environmental exposure in a mining site, south China.

    PubMed

    Zhang, Xin-Ying; Carpenter, David O; Song, Yong-Jin; Chen, Ping; Qin, Yaoming; Wei, Ni-Yu; Lin, Shan-Chun

    2017-12-01

    This study consisted of a site- and age-specific investigation linking children's blood lead level (BLL) to environmental exposures in a historic mining site in south China. A total of 151 children, aged 3-7 years, were included in this study. The geometric mean (GM) BLL was 8.22 μg/dl, indicating an elevated BLL. The Integrated Exposure Uptake Bio-Kinetic (IEUBK) model has proven useful at many sites for study of routes of exposure. Application of the IEUBK model to these children indicated that the GM difference between observed and predicted BLL levels was only 1.07 μg/dl. It was found that the key environmental exposure pathway was soil/dust intake, which contributed 86.3% to the total risk. Younger children had higher BLL than did older children. Therefore, of the various low risk-high benefit solutions, interventions for the children living near the site should be focused on the dust removal and soil remediation. Implementation of the China Eco-village Construction Plan and China New Rural Reconstruction Movement of the government may be a better solution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Organ and effective dose coefficients for cranial and caudal irradiation geometries: Neutrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.

    Dose coefficients based on the recommendations of International Commission on Radiological Protection (ICRP) Publication 103 were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57 for the six reference irradiation geometries: anterior–posterior, posterior–anterior, right and left lateral, rotational and isotropic. In this work, dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and downward from above the head (cranial) using the ICRP 103 methodology were computed using the MCNP 6.1 radiation transport code. The dose coefficients were determined for neutrons ranging in energy from 10more » –9 MeV to 10 GeV. Here, at energies below about 500 MeV, the cranial and caudal dose coefficients are less than those for the six reference geometries reported in ICRP Publication 116.« less

  3. Organ and effective dose coefficients for cranial and caudal irradiation geometries: Neutrons

    DOE PAGES

    Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.; ...

    2016-08-29

    Dose coefficients based on the recommendations of International Commission on Radiological Protection (ICRP) Publication 103 were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57 for the six reference irradiation geometries: anterior–posterior, posterior–anterior, right and left lateral, rotational and isotropic. In this work, dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and downward from above the head (cranial) using the ICRP 103 methodology were computed using the MCNP 6.1 radiation transport code. The dose coefficients were determined for neutrons ranging in energy from 10more » –9 MeV to 10 GeV. Here, at energies below about 500 MeV, the cranial and caudal dose coefficients are less than those for the six reference geometries reported in ICRP Publication 116.« less

  4. Computational fluid dynamics modeling of Bacillus anthracis spore deposition in rabbit and human respiratory airways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kabilan, S.; Suffield, S. R.; Recknagle, K. P.

    Three-dimensional computational fluid dynamics and Lagrangian particle deposition models were developed to compare the deposition of aerosolized Bacillus anthracis spores in the respiratory airways of a human with that of the rabbit, a species commonly used in the study of anthrax disease. The respiratory airway geometries for each species were derived respectively from computed tomography (CT) and µCT images. Both models encompassed airways that extended from the external nose to the lung with a total of 272 outlets in the human model and 2878 outlets in the rabbit model. All simulations of spore deposition were conducted under transient, inhalation–exhalation breathingmore » conditions using average species-specific minute volumes. Two different exposure scenarios were modeled in the rabbit based upon experimental inhalation studies. For comparison, human simulations were conducted at the highest exposure concentration used during the rabbit experimental exposures. Results demonstrated that regional spore deposition patterns were sensitive to airway geometry and ventilation profiles. Due to the complex airway geometries in the rabbit nose, higher spore deposition efficiency was predicted in the nasal sinus compared to the human at the same air concentration of anthrax spores. In contrast, higher spore deposition was predicted in the lower conducting airways of the human compared to the rabbit lung due to differences in airway branching pattern. This information can be used to refine published and ongoing biokinetic models of inhalation anthrax spore exposures, which currently estimate deposited spore concentrations based solely upon exposure concentrations and inhaled doses that do not factor in species-specific anatomy and physiology for deposition.« less

  5. Computational Fluid Dynamics Modeling of Bacillus anthracis Spore Deposition in Rabbit and Human Respiratory Airways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kabilan, Senthil; Suffield, Sarah R.; Recknagle, Kurtis P.

    Three-dimensional computational fluid dynamics and Lagrangian particle deposition models were developed to compare the deposition of aerosolized Bacillus anthracis spores in the respiratory airways of a human with that of the rabbit, a species commonly used in the study of anthrax disease. The respiratory airway geometries for each species were derived from computed tomography (CT) or µCT images. Both models encompassed airways that extended from the external nose to the lung with a total of 272 outlets in the human model and 2878 outlets in the rabbit model. All simulations of spore deposition were conducted under transient, inhalation-exhalation breathing conditionsmore » using average species-specific minute volumes. The highest exposure concentration was modeled in the rabbit based upon prior acute inhalation studies. For comparison, human simulation was also conducted at the same concentration. Results demonstrated that regional spore deposition patterns were sensitive to airway geometry and ventilation profiles. Due to the complex airway geometries in the rabbit nose, higher spore deposition efficiency was predicted in the upper conducting airways compared to the human at the same air concentration of anthrax spores. As a result, higher particle deposition was predicted in the conducting airways and deep lung of the human compared to the rabbit lung due to differences in airway branching pattern. This information can be used to refine published and ongoing biokinetic models of inhalation anthrax spore exposures, which currently estimate deposited spore concentrations based solely upon exposure concentrations and inhaled doses that do not factor in species-specific anatomy and physiology.« less

  6. Updated mortality analysis of radiation workers at Rocketdyne (Atomics International), 1948-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boice, John; Cohen, Sarah; Mumma, Michael

    Updated analyses of mortality data are presented on 5,801 radiation workers, including 2,232 monitored for radionuclide intakes, and 41,169 non-radiation workers employed 1948-1999 at Rocketdyne (Atomics International). The worker population is unique in that lifetime occupational doses from all places of employment were sought and incorporated into the analyses. Further, radiation doses from intakes of 14 different radionuclides were calculated for 16 organs or tissues using biokinetic models of the International Commission on Radiation Protection (ICRP). The mean dose from external radiation was 13.5 mSv (maximum 1 Sv), and the mean lung dose from external and internal radiation combined wasmore » 19.0 mSv (maximum 3.6 Sv). An additional nine years of follow-up, from December 31,1999 through 2008, increased the person-years of observation by 21.7% to 196,674 (mean 33.9 years) and the number of cancer deaths by 50% to 684. Analyses included comparisons with the general population and the computation of standardized mortality ratios (SMRs), and internal comparisons using proportional hazards models. All cancers taken together (SMR 0.88; 95% CI 0.81-0.95), lung cancer (SMR 0.87; 95% CI 0.76-1.00) and leukemia other than chronic lymphocytic leukemia (CLL) (SMR 1.04; 95% 0.67-1.53) were not significantly elevated. Cox regression analyses revealed no significant dose-response trends for any cancer. For all cancers excluding leukemia, the relative risk (RR) at 100 mSv was estimated as 0.98 (95% CI 0.82-1.17) and for all leukemia other than CLL it was 1.06 (95% CI 0.50-2.23). Uranium was the primary radionuclide contributing to internal exposures, but significant increases in lung and kidney disease were not seen. The extended follow-up re-enforces the findings in the previous study in failing to observe a detectable increase in cancer deaths associated with radiation, but strong conclusions still cannot be drawn because of small numbers and relatively low career doses

  7. Analysis of real-time mixture cytotoxicity data following repeated exposure using BK/TD models.

    PubMed

    Teng, S; Tebby, C; Barcellini-Couget, S; De Sousa, G; Brochot, C; Rahmani, R; Pery, A R R

    2016-08-15

    Cosmetic products generally consist of multiple ingredients. Thus, cosmetic risk assessment has to deal with mixture toxicity on a long-term scale which means it has to be assessed in the context of repeated exposure. Given that animal testing has been banned for cosmetics risk assessment, in vitro assays allowing long-term repeated exposure and adapted for in vitro - in vivo extrapolation need to be developed. However, most in vitro tests only assess short-term effects and consider static endpoints which hinder extrapolation to realistic human exposure scenarios where concentration in target organs is varies over time. Thanks to impedance metrics, real-time cell viability monitoring for repeated exposure has become possible. We recently constructed biokinetic/toxicodynamic models (BK/TD) to analyze such data (Teng et al., 2015) for three hepatotoxic cosmetic ingredients: coumarin, isoeugenol and benzophenone-2. In the present study, we aim to apply these models to analyze the dynamics of mixture impedance data using the concepts of concentration addition and independent action. Metabolic interactions between the mixture components were investigated, characterized and implemented in the models, as they impacted the actual cellular exposure. Indeed, cellular metabolism following mixture exposure induced a quick disappearance of the compounds from the exposure system. We showed that isoeugenol substantially decreased the metabolism of benzophenone-2, reducing the disappearance of this compound and enhancing its in vitro toxicity. Apart from this metabolic interaction, no mixtures showed any interaction, and all binary mixtures were successfully modeled by at least one model based on exposure to the individual compounds. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Children's Lead Exposure: A Multimedia Modeling Analysis to Guide Public Health Decision-Making.

    PubMed

    Zartarian, Valerie; Xue, Jianping; Tornero-Velez, Rogelio; Brown, James

    2017-09-12

    Drinking water and other sources for lead are the subject of public health concerns around the Flint, Michigan, drinking water and East Chicago, Indiana, lead in soil crises. In 2015, the U.S. Environmental Protection Agency (EPA)'s National Drinking Water Advisory Council (NDWAC) recommended establishment of a "health-based, household action level" for lead in drinking water based on children's exposure. The primary objective was to develop a coupled exposure-dose modeling approach that can be used to determine what drinking water lead concentrations keep children's blood lead levels (BLLs) below specified values, considering exposures from water, soil, dust, food, and air. Related objectives were to evaluate the coupled model estimates using real-world blood lead data, to quantify relative contributions by the various media, and to identify key model inputs. A modeling approach using the EPA's Stochastic Human Exposure and Dose Simulation (SHEDS)-Multimedia and Integrated Exposure Uptake and Biokinetic (IEUBK) models was developed using available data. This analysis for the U.S. population of young children probabilistically simulated multimedia exposures and estimated relative contributions of media to BLLs across all population percentiles for several age groups. Modeled BLLs compared well with nationally representative BLLs (0-23% relative error). Analyses revealed relative importance of soil and dust ingestion exposure pathways and associated Pb intake rates; water ingestion was also a main pathway, especially for infants. This methodology advances scientific understanding of the relationship between lead concentrations in drinking water and BLLs in children. It can guide national health-based benchmarks for lead and related community public health decisions. https://doi.org/10.1289/EHP1605.

  9. Grouping nanomaterials to predict their potential to induce pulmonary inflammation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braakhuis, Hedwig M., E-mail: hedwig.braakhuis@rivm.nl; Department of Toxicogenomics, Maastricht University, PO Box 616, 6200 MD Maastricht; Oomen, Agnes G.

    The rapidly expanding manufacturing, production and use of nanomaterials have raised concerns for both worker and consumer safety. Various studies have been published in which induction of pulmonary inflammation after inhalation exposure to nanomaterials has been described. Nanomaterials can vary in aspects such as size, shape, charge, crystallinity, chemical composition, and dissolution rate. Currently, efforts are made to increase the knowledge on the characteristics of nanomaterials that can be used to categorise them into hazard groups according to these characteristics. Grouping helps to gather information on nanomaterials in an efficient way with the aim to aid risk assessment. Here, wemore » discuss different ways of grouping nanomaterials for their risk assessment after inhalation. Since the relation between single intrinsic particle characteristics and the severity of pulmonary inflammation is unknown, grouping of nanomaterials by their intrinsic characteristics alone is not sufficient to predict their risk after inhalation. The biokinetics of nanomaterials should be taken into account as that affects the dose present at a target site over time. The parameters determining the kinetic behaviour are not the same as the hazard-determining parameters. Furthermore, characteristics of nanomaterials change in the life-cycle, resulting in human exposure to different forms and doses of these nanomaterials. As information on the biokinetics and in situ characteristics of nanomaterials is essential but often lacking, efforts should be made to include these in testing strategies. Grouping nanomaterials will probably be of the most value to risk assessors when information on intrinsic characteristics, life-cycle, biokinetics and effects are all combined. - Highlights: • Grouping of nanomaterials helps to gather information in an efficient way with the aim to aid risk assessment. • Different ways of grouping nanomaterials for their risk assessment after inhalation

  10. Uranium mining industry views on ICRP statement on radon.

    PubMed

    Takala, J

    2012-01-01

    In 2009, the International Commission on Radiological Protection issued a statement on radon which stated that the dose conversion factor for radon progeny would likely double, and the calculation of risk from radon should move to a dosimetric approach, rather than the longstanding epidemiological approach. Through the World Nuclear Association, whose members represent over 90% of the world's uranium production, industry has been examining this issue with a goal of offering expertise and knowledge to assist with the practical implementation of these evolutionary changes to evaluating the risk from radon progeny. Industry supports the continuing use of the most current epidemiological data as a basis for risk calculation, but believes that further examination of these results is needed to better understand the level of conservatism in the potential epidemiological-based risk models. With regard to adoption of the dosimetric approach, industry believes that further work is needed before this is a practical option. In particular, this work should include a clear demonstration of the validation of the dosimetric model which includes how smoking is handled, the establishment of a practical measurement protocol, and the collection of relevant data for modern workplaces. Industry is actively working to address the latter two items. Copyright © 2012. Published by Elsevier Ltd.

  11. Determination of the solubility and size distribution of radioactive aerosols in the uranium processing plant at NRCN.

    PubMed

    Kravchik, T; Oved, S; Paztal-Levy, O; Pelled, O; Gonen, R; German, U; Tshuva, A

    2008-01-01

    Inhalation is the main route of internal exposure to radioactive aerosols in the nuclear industry. To assess the radiation dose from the intake of these aerosols, it is necessary to know their physical (aerodynamic diameter distribution) and chemical (dissolution rate in extracellular lung fluid) characteristics. Air samples were taken from the uranium processing plant at the Nuclear Research Center, Negev. Measurements of aerodynamic diameter distribution using a cascade impactor indicated an average activity median aerodynamic diameter value close to 5 microm, in accordance with the recent recommended values of International Commission on Radiological Protection (ICRP) model. Solubility profiles of these aerosols were determined by performing in vitro solubility tests over 100 d in a simultant solution of the extracellular fluid. The tests indicated that the uranium aerosols should be assigned to an absorption between Types M and S (as defined by the ICRP Publication 66 model).

  12. Public member dose assessment of Bushehr Nuclear Power Plant under normal operation by modeling the fallout from stack using the HYSPLIT atmospheric dispersion model.

    PubMed

    Zali, A; Shamsaei Zafarghandi, M; Feghhi, S A; Taherian, A M

    2017-05-01

    In this work, public dose resulting from fission products released from Bushehr Nuclear Power Plant (BNPP) under normal operation is assessed. Due to the long range transport of radionuclides in this work (80 km) and considering terrain and meteorological data, HYbrid Single-Particle Lagrangian Integrated Trajectory (HYsplit) model, which uses three dimensional long-range numerical models, has been employed to calculate atmospheric dispersion. Annual effective dose calculation is carried out for inhalation, ingestion, and external exposure pathways in 16directions and within 80 km around the site for representative person. The results showed the maximum dose of inhalation and external exposure for adults is 3.8 × 10 -8 Sv/y in the SE direction and distance of 600 m from the BNPP site which is less than ICRP 103 recommended dose limit (1 mSv). Children and infants' doses are higher in comparison with adults, although they are less than 1 mSv. Ingestion dose percentage in the total dose is less than 0.1%. The results of this study underestimate the Final Safety Analysis Report ofBNPP-1 (FSAR)data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Evolution of the Radiological Protection System and its Implementation.

    PubMed

    Lazo, Edward

    2016-02-01

    The International System of Radiological Protection, developed, maintained, and elaborated by the International Commission on Radiological Protection (ICRP) has, for the past 50 y, provided a robust framework for developing radiological protection policy, regulation, and application. It has, however, been evolving as a result of experience with its implementation, modernization of social awareness of a shrinking world where the Internet links everyone instantly, and increasing public interest in safety-related decisions. These currents have gently pushed the ICRP in recent years to focus more sharply on particular aspects of its system: optimization, prevailing circumstances, the use of effective dose and aspects of an individual's risk, and consideration of the independent implementation of the international system's elements. This paper will present these issues and their relevance to the ICRP system of protection and its evolution. The broader framework of radiological protection (e.g., science, philosophy, policy, regulation, implementation), of which the ICRP is an important element, will provide a global, equally evolving context for this characterization of the changing ICRP system of radiological protection.

  14. Application of the Commission's recommendations: the 2013-2017 Committee 4 programme of work.

    PubMed

    Lochard, J

    2015-06-01

    Committee 4 of the International Commission on Radiological Protection (ICRP) is responsible for developing principles, recommendations, and guidance on the protection of people against radiation exposure, and to consider their practical application in all exposure situations. Currently, the Committee's efforts are focused on the completion of a series of future ICRP publications on the implementation of its 2007 Recommendations to the various existing exposure situations. A report on protection against radon exposure was published recently (ICRP Publication 126), and two documents on protection against cosmic radiation in aviation, and naturally occurring radioactive material are under development. The programme of work for the forthcoming 2013-2017 period comprises the update of ICRP Publication 109 on protection of people in emergency exposure situations, and the update of ICRP Publication 111 on protection of people living in long-term contaminated areas after a nuclear accident, as well as the development of a future ICRP publication on the ethics of radiological protection. It also includes the preparation of task groups on the application of the Commission's recommendations for contaminated sites from past activities and for surface and near-surface disposal of radioactive waste. Another important task for Committee 4 will be to develop a reflection on the tolerability of risk from radiation. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries: Neutrons

    NASA Astrophysics Data System (ADS)

    Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.; Hiller, M. M.

    2017-09-01

    With the introduction of new recommendations by ICRP Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors, and the introduction of reference sex-specific computational phantoms (ICRP Publication 110). Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue absorbed doses for caudal and cranial exposures to neutrons ranging in energy from 10-9 MeV to 10 GeV have been performed using the MCNP6 radiation transport code and the adult reference voxel phantoms of ICRP Publication 110. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above about 30 MeV the cranial and caudal values are greater.

  16. Primate polonium metabolic models and their use in estimation of systemic radiation doses from bioassay data. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, N.

    1989-03-15

    A Polonium metabolic model was derived and incorporated into a Fortran algorithm which estimates the systemic radiation dose from {sup 210}Po when applied to occupational urine bioassay data. The significance of the doses estimated are examined by defining the degree of uncertainty attached to them through comprehensive statistical testing procedures. Many parameters necessary for dosimetry calculations (such as organ partition coefficients and excretion fractions), were evaluated from metabolic studies of {sup 210}Po in non-human primates. Two tamarins and six baboons were injected intravenously with {sup 210}Po citrate. Excreta and blood samples were collected. Five of the baboons were sacrificed atmore » times ranging from 1 day to 3 months post exposure. Complete necropsies were performed and all excreta and the majority of all skeletal and tissue samples were analyzed radiochemically for their {sup 210}Po content. The {sup 210}Po excretion rate in the baboon was more rapid than in the tamarin. The biological half-time of {sup 210}Po excretion in the baboon was approximately 15 days while in the tamarin, the {sup 210}Po excretion rate was in close agreement with the 50 day biological half-time predicted by ICRP 30. Excretion fractions of {sup 210}Po in the non-human primates were found to be markedly different from data reported elsewhere in other species, including man. A thorough review of the Po urinalysis procedure showed that significant recovery losses resulted when metabolized {sup 210}Po was deposited out of raw urine. Polonium-210 was found throughout the soft tissues of the baboon but not with the partition coefficients for liver, kidneys, and spleen that are predicted by the ICRP 30 metabolic model. A fractional distribution of 0.29 for liver, 0.07 for kidneys, and 0.006 for spleen was determined. Retention times for {sup 210}Po in tissues are described by single exponential functions with biological half-times ranging from 15 to 50 days.« less

  17. The limit of detection in scintigraphic imaging with I-131 in patients with differentiated thyroid carcinoma

    NASA Astrophysics Data System (ADS)

    Hänscheid, H.; Lassmann, M.; Buck, A. K.; Reiners, C.; Verburg, F. A.

    2014-05-01

    Radioiodine scintigraphy influences staging and treatment in patients with differentiated thyroid carcinoma. The limit of detection for fractional uptake in an iodine avid focus in a scintigraphic image was determined from the number of lesion net counts and the count density of the tissue background. The count statistics were used to calculate the diagnostic activity required to elevate the signal from a lesion with a given uptake significantly above a homogeneous background with randomly distributed counts per area. The dependences of the minimal uptake and the minimal size of lesions visible in a scan on several parameters of influence were determined by linking the typical biokinetics observed in iodine avid tissue to the lesion mass and to the absorbed dose received in a radioiodine therapy. The detection limits for fractional uptake in a neck lesion of a typical patient are about 0.001% after therapy with 7000 MBq, 0.01% for activities typically administered in diagnostic assessments (74-185 MBq), and 0.1% after the administration of 10 MBq I-131. Lesions at the limit of detection in a diagnostic scan with biokinetics eligible for radioiodine therapy are small with diameters of a few millimeters. Increasing the diagnostic activity by a factor of 4 reduces the diameter of visible lesions by 25% or about 1 mm. Several other determinants have a comparable or higher influence on the limit of detection than the administered activity; most important are the biokinetics in both blood pool and target tissue and the time of measurement. A generally valid recommendation for the timing of the scan is impossible as the time of the highest probability to detect iodine avid tissue depends on the administered activity as well as on the biokinetics in the lesion and background in the individual patient.

  18. Comparison of SPECT aerosol deposition data with a human respiratory tract model.

    PubMed

    Fleming, John S; Epps, Ben P; Conway, Joy H; Martonen, Ted B

    2006-01-01

    Three-dimensional (3D) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data can provide estimates of the deposition per airway generation. In this study, two different nebulizers have been used to deliver radiolabeled aerosols of different particle size to 12 human subjects. Medical imaging has been used to assess the deposition in the body. The deposition pattern has also been estimated using the International Commission on Radiological Protection (ICRP) empirical model and compared to values obtained by experiment. The results showed generally good agreement between model and experiment for both aerosols for the deposition in the extrathoracic and conducting airways. However, there were significant differences in the fate of the remainder of the aerosol between the amount deposited in the alveolar region and that exhaled. The inter-subject variability of deposition predicted by the model was significantly less than that measured, for all regions of the body. The model predicted quite well the differences in deposition distribution pattern between the two aerosols. In conclusion, this study has shown that the ICPR model of inhaled aerosol deposition shows areas of good agreement with results from experiment. However, there are also areas of disagreement, which may be explained by hygroscopic particle growth and individual variation in airway anatomy.

  19. Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons

    DOE PAGES

    Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.

    2015-05-02

    With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision ofmore » ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.« less

  20. Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.

    With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision ofmore » ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.« less

  1. Application of Markov chain Monte Carlo analysis to biomathematical modeling of respirable dust in US and UK coal miners

    PubMed Central

    Sweeney, Lisa M.; Parker, Ann; Haber, Lynne T.; Tran, C. Lang; Kuempel, Eileen D.

    2015-01-01

    A biomathematical model was previously developed to describe the long-term clearance and retention of particles in the lungs of coal miners. The model structure was evaluated and parameters were estimated in two data sets, one from the United States and one from the United Kingdom. The three-compartment model structure consists of deposition of inhaled particles in the alveolar region, competing processes of either clearance from the alveolar region or translocation to the lung interstitial region, and very slow, irreversible sequestration of interstitialized material in the lung-associated lymph nodes. Point estimates of model parameter values were estimated separately for the two data sets. In the current effort, Bayesian population analysis using Markov chain Monte Carlo simulation was used to recalibrate the model while improving assessments of parameter variability and uncertainty. When model parameters were calibrated simultaneously to the two data sets, agreement between the derived parameters for the two groups was very good, and the central tendency values were similar to those derived from the deterministic approach. These findings are relevant to the proposed update of the ICRP human respiratory tract model with revisions to the alveolar-interstitial region based on this long-term particle clearance and retention model. PMID:23454101

  2. Children’s Lead Exposure: A Multimedia Modeling Analysis to Guide Public Health Decision-Making

    PubMed Central

    Xue, Jianping; Tornero-Velez, Rogelio; Brown, James

    2017-01-01

    Background: Drinking water and other sources for lead are the subject of public health concerns around the Flint, Michigan, drinking water and East Chicago, Indiana, lead in soil crises. In 2015, the U.S. Environmental Protection Agency (EPA)’s National Drinking Water Advisory Council (NDWAC) recommended establishment of a “health-based, household action level” for lead in drinking water based on children’s exposure. Objectives: The primary objective was to develop a coupled exposure–dose modeling approach that can be used to determine what drinking water lead concentrations keep children’s blood lead levels (BLLs) below specified values, considering exposures from water, soil, dust, food, and air. Related objectives were to evaluate the coupled model estimates using real-world blood lead data, to quantify relative contributions by the various media, and to identify key model inputs. Methods: A modeling approach using the EPA’s Stochastic Human Exposure and Dose Simulation (SHEDS)-Multimedia and Integrated Exposure Uptake and Biokinetic (IEUBK) models was developed using available data. This analysis for the U.S. population of young children probabilistically simulated multimedia exposures and estimated relative contributions of media to BLLs across all population percentiles for several age groups. Results: Modeled BLLs compared well with nationally representative BLLs (0–23% relative error). Analyses revealed relative importance of soil and dust ingestion exposure pathways and associated Pb intake rates; water ingestion was also a main pathway, especially for infants. Conclusions: This methodology advances scientific understanding of the relationship between lead concentrations in drinking water and BLLs in children. It can guide national health-based benchmarks for lead and related community public health decisions. https://doi.org/10.1289/EHP1605 PMID:28934096

  3. Dosimetric factors for diagnostic nuclear medicine procedures in a non-reference pregnant phantom.

    PubMed

    Rafat-Motavalli, Laleh; Miri Hakimabad, Hashem; Hoseinian Azghadi, Elie

    2018-05-01

    This study was evaluated the impact of using non-reference fetal models on the fetal radiation dose from diagnostic radionuclide administration. The 6 month pregnant phantoms including fetal models at 10th and 90th growth percentiles were constructed at either end of the normal range around the 50th percentile and implemented in the Monte Carlo N-Particle code version MCNPX 2.6. The code have been used then to evaluate the 99mTc S factors of interested target organs as the most common used radionuclide in nuclear medicine procedures. Substantial variations were observed in the S factors between the 10th/90th percentile phantoms from the 50th percentile phantom, with the greatest difference being 38.6 %. When the source organs were in close proximity to, or inside the fetal body, the 99mTc S factors presented strong statistical correlations with fetal body habitus. The trends observed in the S factors and the differences between various percentiles were justified by the source organs' masses, and chord length distributions (CLDs). The results of this study showed that fetal body habitus had a considerable effect on fetal dose (on average up to 8.4%) if constant fetal biokinetic data was considered for all fetal weight percentiles. However, an almost smaller variation on fetal dose (up to 5.3%) was obtained if the available biokinetic data for the reference fetus was scaled by fetal mass. © 2018 IOP Publishing Ltd.

  4. Man-machine analysis of translation and work tasks of Skylab films

    NASA Technical Reports Server (NTRS)

    Hosler, W. W.; Boelter, J. G.; Morrow, J. R., Jr.; Jackson, J. T.

    1979-01-01

    An objective approach to determine the concurrent validity of computer-graphic models is real time film analysis. This technique was illustrated through the procedures and results obtained in an evaluation of translation of Skylab mission astronauts. The quantitative analysis was facilitated by the use of an electronic film analyzer, minicomputer, and specifically supportive software. The uses of this technique for human factors research are: (1) validation of theoretical operator models; (2) biokinetic analysis; (3) objective data evaluation; (4) dynamic anthropometry; (5) empirical time-line analysis; and (6) consideration of human variability. Computer assisted techniques for interface design and evaluation have the potential for improving the capability for human factors engineering.

  5. Estimating Children's Soil/Dust Ingestion Rates through ...

    EPA Pesticide Factsheets

    Background: Soil/dust ingestion rates are important variables in assessing children’s health risks in contaminated environments. Current estimates are based largely on soil tracer methodology, which is limited by analytical uncertainty, small sample size, and short study duration. Objectives: The objective was to estimate site-specific soil/dust ingestion rates through reevaluation of the lead absorption dose–response relationship using new bioavailability data from the Bunker Hill Mining and Metallurgical Complex Superfund Site (BHSS) in Idaho, USA. Methods: The U.S. Environmental Protection Agency (EPA) in vitro bioavailability methodology was applied to archived BHSS soil and dust samples. Using age-specific biokinetic slope factors, we related bioavailable lead from these sources to children’s blood lead levels (BLLs) monitored during cleanup from 1988 through 2002. Quantitative regression analyses and exposure assessment guidance were used to develop candidate soil/dust source partition scenarios estimating lead intake, allowing estimation of age-specific soil/dust ingestion rates. These ingestion rate and bioavailability estimates were simultaneously applied to the U.S. EPA Integrated Exposure Uptake Biokinetic Model for Lead in Children to determine those combinations best approximating observed BLLs. Results: Absolute soil and house dust bioavailability averaged 33% (SD ± 4%) and 28% (SD ± 6%), respectively. Estimated BHSS age-specific soil/du

  6. Estimates of potential childhood lead exposure from contaminated soil using the US EPA IEUBK Model in Sydney, Australia.

    PubMed

    Laidlaw, Mark A S; Mohmmad, Shaike M; Gulson, Brian L; Taylor, Mark P; Kristensen, Louise J; Birch, Gavin

    2017-07-01

    Surface soils in portions of the Sydney (New South Wales, Australia) urban area are contaminated with lead (Pb) primarily from past use of Pb in gasoline, the deterioration of exterior lead-based paints, and industrial activities. Surface soil samples (n=341) were collected from a depth of 0-2.5cm at a density of approximately one sample per square kilometre within the Sydney estuary catchment and analysed for lead. The bioaccessibility of soil Pb was analysed in 18 samples. The blood lead level (BLL) of a hypothetical 24 month old child was predicted at soil sampling sites in residential and open land use using the United States Environmental Protection Agency (US EPA) Integrated Exposure Uptake and Biokinetic (IEUBK) model. Other environmental exposures used the Australian National Environmental Protection Measure (NEPM) default values. The IEUBK model predicted a geometric mean BLL of 2.0±2.1µg/dL using measured soil lead bioavailability measurements (bioavailability =34%) and 2.4±2.8µg/dL using the Australian NEPM default assumption (bioavailability =50%). Assuming children were present and residing at the sampling locations, the IEUBK model incorporating soil Pb bioavailability predicted that 5.6% of the children at the sampling locations could potentially have BLLs exceeding 5µg/dL and 2.1% potentially could have BLLs exceeding 10µg/dL. These estimations are consistent with BLLs previously measured in children in Sydney. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Monitoring Cosmic Radiation Risk: Comparisons between Observations and Predictive Codes for Naval Aviation

    DTIC Science & Technology

    2009-01-01

    proton PARMA PHITS -based Analytical Radiation Model in the Atmosphere PCAIRE Predictive Code for Aircrew Radiation Exposure PHITS Particle and...radiation transport code utilized is called PARMA ( PHITS based Analytical Radiation Model in the Atmosphere) [36]. The particle fluxes calculated from the...same dose equivalent coefficient regulations from the ICRP-60 regulations. As a result, the transport codes utilized by EXPACS ( PHITS ) and CARI-6

  8. Monitoring Cosmic Radiation Risk: Comparisons Between Observations and Predictive Codes for Naval Aviation

    DTIC Science & Technology

    2009-07-05

    proton PARMA PHITS -based Analytical Radiation Model in the Atmosphere PCAIRE Predictive Code for Aircrew Radiation Exposure PHITS Particle and Heavy...transport code utilized is called PARMA ( PHITS based Analytical Radiation Model in the Atmosphere) [36]. The particle fluxes calculated from the input...dose equivalent coefficient regulations from the ICRP-60 regulations. As a result, the transport codes utilized by EXPACS ( PHITS ) and CARI-6 (PARMA

  9. Analysis of real-time mixture cytotoxicity data following repeated exposure using BK/TD models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teng, S.; Tebby, C.

    Cosmetic products generally consist of multiple ingredients. Thus, cosmetic risk assessment has to deal with mixture toxicity on a long-term scale which means it has to be assessed in the context of repeated exposure. Given that animal testing has been banned for cosmetics risk assessment, in vitro assays allowing long-term repeated exposure and adapted for in vitro – in vivo extrapolation need to be developed. However, most in vitro tests only assess short-term effects and consider static endpoints which hinder extrapolation to realistic human exposure scenarios where concentration in target organs is varies over time. Thanks to impedance metrics, real-timemore » cell viability monitoring for repeated exposure has become possible. We recently constructed biokinetic/toxicodynamic models (BK/TD) to analyze such data (Teng et al., 2015) for three hepatotoxic cosmetic ingredients: coumarin, isoeugenol and benzophenone-2. In the present study, we aim to apply these models to analyze the dynamics of mixture impedance data using the concepts of concentration addition and independent action. Metabolic interactions between the mixture components were investigated, characterized and implemented in the models, as they impacted the actual cellular exposure. Indeed, cellular metabolism following mixture exposure induced a quick disappearance of the compounds from the exposure system. We showed that isoeugenol substantially decreased the metabolism of benzophenone-2, reducing the disappearance of this compound and enhancing its in vitro toxicity. Apart from this metabolic interaction, no mixtures showed any interaction, and all binary mixtures were successfully modeled by at least one model based on exposure to the individual compounds. - Highlights: • We could predict cell response over repeated exposure to mixtures of cosmetics. • Compounds acted independently on the cells. • Metabolic interactions impacted exposure concentrations to the compounds.« less

  10. Gastrointestinal absorption of americium-241 by orally exposed swine: comparison of experimental results with predictions of metabolic models.

    PubMed

    Eisele, G R; Bernard, S R; Nestor, C W

    1987-10-01

    Two groups of 11-week-old swine (40 miniature and 40 domestic swine) received a single oral administration of 1.9 X 10(8) Bq (5.2 mCi) of 241Am citrate, and groups of eight animals, four of each type, were killed and sampled at 1, 2, 4, 8, 16, 24, 48, 72, and 96 h and 30 days later. Uptake and excretion patterns of the radioactivity appeared to occur in three phases: rapid uptake, rapid excretion, and then a slower excretion. All animals were systematically dissected, and the eviscerated carcasses were autoclaved for separation of bone and muscle. The predominant site of deposition was bone, and autoclaving had little effect on releasing 241Am from either bone or muscle. The maximum fractional gastrointestinal absorption of 1.1 X 10(-3) occurred 8 h after radionuclide administration. The tissue distribution data suggest partitions of 50, 20, and 30%, for bone, liver, and other soft tissues, respectively. Two metabolic models were evaluated: a modified Mewhinney-Griffith model and the ICRP 30 model to compare the biological data with model predictions. All models underestimated the actual early time data, but the fits to the experimental results were better at later times.

  11. Biokinetics and effects of titania nano-material after inhalation and i.v. injection

    NASA Astrophysics Data System (ADS)

    Landsiedel, Robert; Fabian, Eric; Ma-Hock, Lan; Wiench, Karin; van Ravenzwaay, Bennard

    2009-05-01

    Within NanoSafe2 we developed a special inhalation model to investigate deposition of inhaled particles in the lung and the further distribution in the body after. Concurrently, the effects of the inhaled materials in the lung were examined. The results for nano-Titania were compared to results from inhalation studies with micron-sized (non-nano) Titania particles and to quartz particles (DQ12, known to be potent lung toxicants). To build a PBPK model for nano-Titania the tissue distribution of the material was also examined following intravenous (i.v.) administration.

  12. Involving stakeholders in radiological protection decision making: recovery history and lessons from the people of Fukushima.

    PubMed

    Lazo, T

    2016-12-01

    Between September 2011 and August 2015, the International Commission on Radiological Protection (ICRP) organised a series of 12 stakeholder dialogue workshops with residents of Fukushima Prefecture. Discussions focused on recovery, addressing topics such as protection of children, management of contaminated food, monitoring, and self-help measures. The OECD Nuclear Energy Agency (NEA) supported, and the Committee on Radiation Protection and Public Health (CRPPH) Secretariat attended, all 12 meetings to listen directly to the concerns of affected individuals and draw lessons for CRPPH. To summarise the dialogue results, ICRP organised a final meeting in Date, Japan with the support of NEA and other organisations. The lessons from and utility of the dialogue meetings were praised by dialogue participants and sponsors, and ICRP agreed that some form of dialogue would continue, although with ICRP participation and support rather than leadership. This paper summarises the internationally relevant lessons learned by CRPPH from this important process.

  13. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols.

    PubMed

    Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen

    2010-12-01

    The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.

  14. Age-specific inhalation radiation dose commitment factors for selected radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strenge, D.L.; Peloquin, R.A.; Baker, D.A.

    Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are /sup 35/S, /sup 36/Cl, /sup 45/Ca, /sup 67/Ga, /sup 75/Se, /sup 85/Sr, /sup 109/Cd, /sup 113/Sn, /sup 125/I, /sup 133/Ba, /sup 170/Tm, /sup 169/Yb, /sup 182/Ta, /sup 192/Ir, /sup 198/Au, /sup 201/Tl, /sup 204/Tl, and /sup 236/Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presentedmore » for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine.« less

  15. [Eye lens radiation exposure during ureteroscopy with and without a face protection shield: Investigations on a phantom model].

    PubMed

    Zöller, G; Figel, M; Denk, J; Schulz, K; Sabo, A

    2016-03-01

    Eye lens radiation exposure during radiologically-guided endoscopic procedures may result in radiation-induced cataracts; therefore, we investigated the ocular radiation exposure during ureteroscopy on a phantom model. Using an Alderson phantom model and eye lens dosimeters, we measured the ocular radiation exposure depending on the number of X-ray images and on the duration of fluoroscopic imaging. The measurements were done with and without using a face protection shield. We could demonstrate that a significant ocular radiation exposure can occur, depending on the number of X-ray images and on the duration time of fluoroscopy. Eye lens doses up to 0.025 mSv were recorded even using modern digital X-ray systems. Using face protection shields this ocular radiation exposure can be reduced to a minimum. The International Commission on Radiological Protection (ICRP) recommendations of a mean eye lens dosage of 20 mSv/year may be exceeded during repeated ureteroscopy by a high volume surgeon. Using a face protection shield, the eye lens dose during ureteroscopy could be reduced to a minimum in a phantom model. Further investigations will show whether these results can be transferred to real life ureteroscopic procedures.

  16. Integrating cognitive rehabilitation: A preliminary program description and theoretical review of an interdisciplinary cognitive rehabilitation program.

    PubMed

    Fleeman, Jennifer A; Stavisky, Christopher; Carson, Simon; Dukelow, Nancy; Maier, Sheryl; Coles, Heather; Wager, John; Rice, Jordyn; Essaff, David; Scherer, Marcia

    2015-01-01

    Interdisciplinary cognitive rehabilitation is emerging as the expected standard of care for individuals with mild to moderate degrees of cognitive impairment for a variety of etiologies. There is a growing body of evidence in cognitive rehabilitation literature supporting the involvement of multiple disciplines, with the use of cognitive support technologies (CSTs), in delivering cognitive therapy to individuals who require cognitive rehabilitative therapies. This article provides an overview of the guiding theories related to traditional approaches of cognitive rehabilitation and the positive impact of current theoretical models of an interdisciplinary approach in clinical service delivery of this rehabilitation. A theoretical model of the Integrative Cognitive Rehabilitation Program (ICRP) will be described in detail along with the practical substrates of delivering specific interventions to individuals and caregivers who are living with mild to moderate cognitive impairment. The ultimate goal of this article is to provide a clinically useful resource for direct service providers. It will serve to further clinical knowledge and understanding of the evolution from traditional silo based treatment paradigms to the current implementation of multiple perspectives and disciplines in the pursuit of patient centered care. The article will discuss the theories that contributed to the development of the interdisciplinary team and the ICRP model, implemented with individuals with mild to moderate cognitive deficits, regardless of etiology. The development and implementation of specific assessment and intervention strategies in this cognitive rehabilitation program will also be discussed. The assessment and intervention strategies utilized as part of ICRP are applicable to multiple clinical settings in which individuals with cognitive impairment are served. This article has specific implications for rehabilitation which include: (a) An Interdisciplinary Approach is an

  17. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

    NASA Astrophysics Data System (ADS)

    Cros, Maria; Joemai, Raoul M. S.; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-08-01

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  18. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.

    PubMed

    Cros, Maria; Joemai, Raoul M S; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-07-17

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  19. Uncertainty and sensitivity analysis of control strategies using the benchmark simulation model No1 (BSM1).

    PubMed

    Flores-Alsina, Xavier; Rodriguez-Roda, Ignasi; Sin, Gürkan; Gernaey, Krist V

    2009-01-01

    The objective of this paper is to perform an uncertainty and sensitivity analysis of the predictions of the Benchmark Simulation Model (BSM) No. 1, when comparing four activated sludge control strategies. The Monte Carlo simulation technique is used to evaluate the uncertainty in the BSM1 predictions, considering the ASM1 bio-kinetic parameters and influent fractions as input uncertainties while the Effluent Quality Index (EQI) and the Operating Cost Index (OCI) are focused on as model outputs. The resulting Monte Carlo simulations are presented using descriptive statistics indicating the degree of uncertainty in the predicted EQI and OCI. Next, the Standard Regression Coefficients (SRC) method is used for sensitivity analysis to identify which input parameters influence the uncertainty in the EQI predictions the most. The results show that control strategies including an ammonium (S(NH)) controller reduce uncertainty in both overall pollution removal and effluent total Kjeldahl nitrogen. Also, control strategies with an external carbon source reduce the effluent nitrate (S(NO)) uncertainty increasing both their economical cost and variability as a trade-off. Finally, the maximum specific autotrophic growth rate (micro(A)) causes most of the variance in the effluent for all the evaluated control strategies. The influence of denitrification related parameters, e.g. eta(g) (anoxic growth rate correction factor) and eta(h) (anoxic hydrolysis rate correction factor), becomes less important when a S(NO) controller manipulating an external carbon source addition is implemented.

  20. Using biodynamic models to reconcile differences between laboratory toxicity tests and field biomonitoring with aquatic insects

    USGS Publications Warehouse

    Buchwalter, D.B.; Cain, D.J.; Clements, W.H.; Luoma, S.N.

    2007-01-01

    Aquatic insects often dominate lotic ecosystems, yet these organisms are under-represented in trace metal toxicity databases. Furthermore, toxicity data for aquatic insects do not appear to reflect their actual sensitivities to metals in nature, because the concentrations required to elicit toxicity in the laboratory are considerably higher than those found to impact insect communities in the field. New approaches are therefore needed to better understand how and why insects are differentially susceptible to metal exposures. Biodynamic modeling is a powerful tool for understanding interspecific differences in trace metal bioaccumulation. Because bioaccumulation alone does not necessarily correlate with toxicity, we combined biokinetic parameters associated with dissolved cadmium exposures with studies of the subcellular compartmentalization of accumulated Cd. This combination of physiological traits allowed us to make predictions of susceptibility differences to dissolved Cd in three aquatic insect taxa: Ephemerella excrucians, Rhithrogena morrisoni, and Rhyacophila sp. We compared these predictions with long-term field monitoring data and toxicity tests with closely related taxa: Ephemerella infrequens, Rhithrogena hageni, and Rhyacophila brunea. Kinetic parameters allowed us to estimate steady-state concentrations, the time required to reach steady state, and the concentrations of Cd projected to be in potentially toxic compartments for different species. Species-specific physiological traits identified using biodynamic models provided a means for better understanding why toxicity assays with insects have failed to provide meaningful estimates for metal concentrations that would be expected to be protective in nature. ?? 2007 American Chemical Society.

  1. Relationships (I) of International Classification of High-resolution Computed Tomography for Occupational and Environmental Respiratory Diseases with the ILO International Classification of Radiographs of Pneumoconioses for parenchymal abnormalities.

    PubMed

    Tamura, Taro; Suganuma, Narufumi; Hering, Kurt G; Vehmas, Tapio; Itoh, Harumi; Akira, Masanori; Takashima, Yoshihiro; Hirano, Harukazu; Kusaka, Yukinori

    2015-01-01

    The International Classification of High-resolution Computed Tomography (HRCT) for Occupational and Environmental Respiratory Diseases (ICOERD) has been developed for the screening, diagnosis, and epidemiological reporting of respiratory diseases caused by occupational hazards. This study aimed to establish a correlation between readings of HRCT (according to the ICOERD) and those of chest radiography (CXR) pneumoconiotic parenchymal opacities (according to the International Labor Organization Classification/International Classification of Radiographs of Pneumoconioses [ILO/ICRP]). Forty-six patients with and 28 controls without mineral dust exposure underwent posterior-anterior CXR and HRCT. We recorded all subjects' exposure and smoking history. Experts independently read CXRs (using ILO/ICRP). Experts independently assessed HRCT using the ICOERD parenchymal abnormalities grades for well-defined rounded opacities (RO), linear and/or irregular opacities (IR), and emphysema (EM). The correlation between the ICOERD summed grades and ILO/ICRP profusions was evaluated using Spearman's rank-order correlation. Twenty-three patients had small opacities on CXR. HRCT showed that 21 patients had RO; 20 patients, IR opacities; and 23 patients, EM. The correlation between ILO/ICRP profusions and the ICOERD grades was 0.844 for rounded opacities (p<0.01). ICOERD readings from HRCT scans correlated well with previously validated ILO/ICRP criteria. The ICOERD adequately detects pneumoconiotic micronodules and can be used for the interpretation of pneumoconiosis.

  2. Biokinetics and Biodynamics of Nanomaterial Interactions

    DTIC Science & Technology

    2009-09-30

    HEK viability. The medium from each treatment set of the dosed cells was removed, pooled into a microfuge tube , and quickly frozen to -80ºC until...Trump’s fixative at 4ºC. The cells were rinsed in 0.1M phosphate buffer (pH 7.2), pelleted in a microfuge tube , resuspended, and quickly pelleted in 3...formulation on in vitro human skin localized NP in the upper stratum corneum with minimal penetration (Cross et al., 2007) and microfine zinc oxide with a

  3. Adsorption with biodegradation for decolorization of reactive black 5 by Funalia trogii 200800 on a fly ash-chitosan medium in a fluidized bed bioreactor-kinetic model and reactor performance.

    PubMed

    Lin, Yen-Hui; Lin, Wen-Fan; Jhang, Kai-Ning; Lin, Pei-Yu; Lee, Mong-Chuan

    2013-02-01

    A non-steady-state mathematical model system for the kinetics of adsorption and biodegradation of reactive black 5 (RB5) by Funalia trogii (F. trogii) ATCC 200800 biofilm on fly ash-chitosan bead in the fluidized bed process was derived. The mechanisms in the model system included adsorption by fly ash-chitosan beads, biodegradation by F. trogii cells and mass transport diffusion. Batch kinetic tests were independently performed to determine surface diffusivity of RB5, adsorption parameters for RB5 and biokinetic parameters of F. trogii ATCC 200800. A column test was conducted using a continuous-flow fluidized bed reactor with a recycling pump to approximate a completely-mixed flow reactor for model verification. The experimental results indicated that F. trogii biofilm bioregenerated the fly ash-chitosan beads after attached F. trogii has grown significantly. The removal efficiency of RB5 was about 95 % when RB5 concentration in the effluent was approximately 0.34 mg/L at a steady-state condition. The concentration of suspended F. trogii cells reached up to about 1.74 mg/L while the thickness of attached F. trogii cells was estimated to be 80 μm at a steady-state condition by model prediction. The comparisons of experimental data and model prediction show that the model system for adsorption and biodegradation of RB5 can predict the experimental results well. The approaches of experiments and mathematical modeling in this study can be applied to design a full-scale fluidized bed process to treat reactive dye in textile wastewater.

  4. Development and evaluation of a technique for in vivo monitoring of 60Co in human lungs

    NASA Astrophysics Data System (ADS)

    de Mello, J. Q.; Lucena, E. A.; Dantas, A. L. A.; Dantas, B. M.

    2016-07-01

    60Co is a fission product of 235U and represents a risk of internal exposure of workers in nuclear power plants, especially those involved in the maintenance of potentially contaminated parts and equipment. The control of 60Co intake by inhalation can be performed through in vivo monitoring. This work describes the evaluation of a technique through the minimum detectable activity and the corresponding minimum detectable effective doses, based on biokinetic and dosimetric models of 60Co in the human body. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intake.

  5. The UF family of reference hybrid phantoms for computational radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Lee, Choonsik; Lodwick, Daniel; Hurtado, Jorge; Pafundi, Deanna; Williams, Jonathan L.; Bolch, Wesley E.

    2010-01-01

    Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms—those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR™. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros™. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference

  6. A physiologically based biodynamic (PBBD) model for estragole DNA binding in rat liver based on in vitro kinetic data and estragole DNA adduct formation in primary hepatocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paini, Alicia, E-mail: alicia.paini@rdls.nestle.co; Nestle Research Center, PO Box 44, Lausanne; Punt, Ans

    2010-05-15

    Estragole has been shown to be hepatocarcinogenic in rodent species at high-dose levels. Translation of these results into the likelihood of formation of DNA adducts, mutation, and ultimately cancer upon more realistic low-dose exposures remains a challenge. Recently we have developed physiologically based biokinetic (PBBK) models for rat and human predicting bioactivation of estragole. These PBBK models, however, predict only kinetic characteristics. The present study describes the extension of the PBBK model to a so-called physiologically based biodynamic (PBBD) model predicting in vivo DNA adduct formation of estragole in rat liver. This PBBD model was developed using in vitro datamore » on DNA adduct formation in rat primary hepatocytes exposed to 1'-hydroxyestragole. The model was extended by linking the area under the curve for 1'-hydroxyestragole formation predicted by the PBBK model to the area under the curve for 1'-hydroxyestragole in the in vitro experiments. The outcome of the PBBD model revealed a linear increase in DNA adduct formation with increasing estragole doses up to 100 mg/kg bw. Although DNA adduct formation of genotoxic carcinogens is generally seen as a biomarker of exposure rather than a biomarker of response, the PBBD model now developed is one step closer to the ultimate toxic effect of estragole than the PBBK model described previously. Comparison of the PBBD model outcome to available data showed that the model adequately predicts the dose-dependent level of DNA adduct formation. The PBBD model predicts DNA adduct formation at low levels of exposure up to a dose level showing to cause cancer in rodent bioassays, providing a proof of principle for modeling a toxicodynamic in vivo endpoint on the basis of solely in vitro experimental data.« less

  7. Acellular assessments of engineered-manufactured nanoparticle biological surface reactivity

    EPA Science Inventory

    It is critical to assess the surface properties and reactivity of engineered-manufactured nanoparticles (NPs) as these will influence their interactions with biological systems, biokinetics and toxicity. We examined the physicochemical properties and surface reactivity of metal o...

  8. Modelling of aircrew radiation exposure from galactic cosmic rays and solar particle events.

    PubMed

    Takada, M; Lewis, B J; Boudreau, M; Al Anid, H; Bennett, L G I

    2007-01-01

    Correlations have been developed for implementation into the semi-empirical Predictive Code for Aircrew Radiation Exposure (PCAIRE) to account for effects of extremum conditions of solar modulation and low altitude based on transport code calculations. An improved solar modulation model, as proposed by NASA, has been further adopted to interpolate between the bounding correlations for solar modulation. The conversion ratio of effective dose to ambient dose equivalent, as applied to the PCAIRE calculation (based on measurements) for the legal regulation of aircrew exposure, was re-evaluated in this work to take into consideration new ICRP-92 radiation-weighting factors and different possible irradiation geometries of the source cosmic-radiation field. A computational analysis with Monte Carlo N-Particle eXtended Code was further used to estimate additional aircrew exposure that may result from sporadic solar energetic particle events considering real-time monitoring by the Geosynchronous Operational Environmental Satellite. These predictions were compared with the ambient dose equivalent rates measured on-board an aircraft and to count rate data observed at various ground-level neutron monitors.

  9. THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2013) FOR INTERNALLY DEPOSITED PLUTONIUM: AN OVERVIEW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birchall, A.; Vostrotin, V.; Puncher, M.

    The Mayak Worker Dosimetry System (MWDS-2013) is a system for interpreting measurement data from Mayak workers from both internal and external sources. This paper is concerned with the calculation of annual organ doses for Mayak workers exposed to plutonium aerosols, where the measurement data consists mainly of activity of plutonium in urine samples. The system utilises the latest biokinetic and dosimetric models, and unlike its predecessors, takes explicit account of uncertainties in both the measurement data and model parameters. The aim of this paper is to describe the complete MWDS-2013 system (including model parameter values and their uncertainties) and themore » methodology used (including all the relevant equations) and the assumptions made. Where necessary, supplementary papers which justify specific assumptions are cited.« less

  10. Using the Monte Carlo method for assessing the tissue and organ doses of patients in dental radiography

    NASA Astrophysics Data System (ADS)

    Makarevich, K. O.; Minenko, V. F.; Verenich, K. A.; Kuten, S. A.

    2016-05-01

    This work is dedicated to modeling dental radiographic examinations to assess the absorbed doses of patients and effective doses. For simulating X-ray spectra, the TASMIP empirical model is used. Doses are assessed on the basis of the Monte Carlo method by using MCNP code for voxel phantoms of ICRP. The results of the assessment of doses to individual organs and effective doses for different types of dental examinations and features of X-ray tube are presented.

  11. DEVELOPMENT OF PREDICTIVE STRUCTURE-BIODEGRADATION RELATIONSHIP MODELS WITH THE USE OF RESPIROMETRICALLY GENERATED BIOKINETIC DATA

    EPA Science Inventory

    Biodegradation is an important mechanism determining the fate of chemicals in the aquatic environment. In this paper, experimental data, determined from electrolytic respirometry, for 27 compounds were analyzed using first order and Monod kinetics. Additional data from the lite...

  12. The Cartridge Theory: a description of the functioning of horizontal subsurface flow constructed wetlands for wastewater treatment, based on modelling results.

    PubMed

    Samsó, Roger; García, Joan

    2014-03-01

    Despite the fact that horizontal subsurface flow constructed wetlands have been in operation for several decades now, there is still no clear understanding of some of their most basic internal functioning patterns. To fill this knowledge gap, on this paper we present what we call "The Cartridge Theory". This theory was derived from simulation results obtained with the BIO_PORE model and explains the functioning of urban wastewater treatment wetlands based on the interaction between bacterial communities and the accumulated solids leading to clogging. In this paper we start by discussing some changes applied to the biokinetic model implemented in BIO_PORE (CWM1) so that the growth of bacterial communities is consistent with a well-known population dynamics models. This discussion, combined with simulation results for a pilot wetland system, led to the introduction of "The Cartridge Theory", which states that the granular media of horizontal subsurface flow wetlands can be assimilated to a generic cartridge which is progressively consumed (clogged) with inert solids from inlet to outlet. Simulations also revealed that bacterial communities are poorly distributed within the system and that their location is not static but changes over time, moving towards the outlet as a consequence of the progressive clogging of the granular media. According to these findings, the life-span of constructed wetlands corresponds to the time when bacterial communities are pushed as much towards the outlet that their biomass is not anymore sufficient to remove the desirable proportion of the influent pollutants. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Dose conversion coefficients for electron exposure of the human eye lens: calculations including a whole body phantom.

    PubMed

    Behrens, R

    2013-07-01

    In this work, conversion coefficients from electron fluence to absorbed dose to the eye lens were calculated using Monte Carlo simulations based on a detailed stylised eye model and a very simple but whole body phantom. These data supersede and complement data published earlier based on the simulation of only a single stylised eye. The new data differ from the old ones by not more than 3, 4, 7 and 16 % for angles of radiation incidence of α=0°, 15°, 30° and 45°, respectively, due to the inclusion of the whole body phantom. The data presented in the present work also complement those of a recent report of the International Commission on Radiological Protection (ICRP) (ICRP Publication 116), where conversion coefficients from electron fluence to absorbed dose to the lens of the eye are shown for solely 0°, 180° and isotropic radiation incidence (but for a much broader range of energies). In this article, values are provided for angles of incidence of 0° up to 180° in steps of 15° and for rotational geometry; no systematic deviation was observed from the values given in ICRP Publication 116 for 0° (based on the application of a bare eye) and 180° (based on the application of a voxel whole body phantom). Data are given for monoenergetic electrons from 0.1 up to 10 MeV and for a broad parallel beam geometry in vacuum.

  14. Health effects models for nuclear power plant accident consequence analysis. Part 1, Introduction, integration, and summary: Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, J.S.; Abrahmson, S.; Bender, M.A.

    1993-10-01

    This report is a revision of NUREG/CR-4214, Rev. 1, Part 1 (1990), Health Effects Models for Nuclear Power Plant Accident Consequence Analysis. This revision has been made to incorporate changes to the Health Effects Models recommended in two addenda to the NUREG/CR-4214, Rev. 1, Part 11, 1989 report. The first of these addenda provided recommended changes to the health effects models for low-LET radiations based on recent reports from UNSCEAR, ICRP and NAS/NRC (BEIR V). The second addendum presented changes needed to incorporate alpha-emitting radionuclides into the accident exposure source term. As in the earlier version of this report, modelsmore » are provided for early and continuing effects, cancers and thyroid nodules, and genetic effects. Weibull dose-response functions are recommended for evaluating the risks of early and continuing health effects. Three potentially lethal early effects -- the hematopoietic, pulmonary, and gastrointestinal syndromes are considered. Linear and linear-quadratic models are recommended for estimating the risks of seven types of cancer in adults - leukemia, bone, lung, breast, gastrointestinal, thyroid, and ``other``. For most cancers, both incidence and mortality are addressed. Five classes of genetic diseases -- dominant, x-linked, aneuploidy, unbalanced translocations, and multifactorial diseases are also considered. Data are provided that should enable analysts to consider the timing and severity of each type of health risk.« less

  15. In Vitro Vascular Toxicity of Manufactured Metal Oxide Nanoparticles: Size Profile Predicts Cellular Specificity, Delivered Dose, and Toxicity

    EPA Science Inventory

    Metal oxide nanoparticles (NPs) are being used in an expanding range of products and applications due to their unique physicochemical properties. In vivo biokinetic studies have demonstrated the ability of metal oxide NPs to translocate to the distal organs, including the cardiov...

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, P.K.N.; Lam, P.K.S.; Ng, B.K.P.

    The biokinetics of Cs in four compartments in the green-lipped mussel Perna viridis, namely, gill, viscera, adductor muscle, and foot, were studied. First-order linear differential equations were set up for these four compartments, and their solutions were used to fit the experimental data. The parameters governing the biokinetics, which depend on the elimination rate from each compartment and the transfer coefficient between compartments, were found. These are useful in understanding the physiology of Perna viridis, in predicting the activity of cesium in each compartment of Perna viridis from a contamination history, or in using Perna viridis as a sentinel organismmore » for surveying and monitoring radioactive contamination. The results showed that the viscera should be represented by more than one compartment. Concentration factors for the four compartments and for Perna viridis were also determined, and these agreed well with reported values in the literature.« less

  17. Comprehensive summary--Predict-IV: A systems toxicology approach to improve pharmaceutical drug safety testing.

    PubMed

    Mueller, Stefan O; Dekant, Wolfgang; Jennings, Paul; Testai, Emanuela; Bois, Frederic

    2015-12-25

    This special issue of Toxicology in Vitro is dedicated to disseminating the results of the EU-funded collaborative project "Profiling the toxicity of new drugs: a non animal-based approach integrating toxicodynamics and biokinetics" (Predict-IV; Grant 202222). The project's overall aim was to develop strategies to improve the assessment of drug safety in the early stage of development and late discovery phase, by an intelligent combination of non animal-based test systems, cell biology, mechanistic toxicology and in silico modeling, in a rapid and cost effective manner. This overview introduces the scope and overall achievements of Predict-IV. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Grouping nanomaterials to predict their potential to induce pulmonary inflammation.

    PubMed

    Braakhuis, Hedwig M; Oomen, Agnes G; Cassee, Flemming R

    2016-05-15

    The rapidly expanding manufacturing, production and use of nanomaterials have raised concerns for both worker and consumer safety. Various studies have been published in which induction of pulmonary inflammation after inhalation exposure to nanomaterials has been described. Nanomaterials can vary in aspects such as size, shape, charge, crystallinity, chemical composition, and dissolution rate. Currently, efforts are made to increase the knowledge on the characteristics of nanomaterials that can be used to categorise them into hazard groups according to these characteristics. Grouping helps to gather information on nanomaterials in an efficient way with the aim to aid risk assessment. Here, we discuss different ways of grouping nanomaterials for their risk assessment after inhalation. Since the relation between single intrinsic particle characteristics and the severity of pulmonary inflammation is unknown, grouping of nanomaterials by their intrinsic characteristics alone is not sufficient to predict their risk after inhalation. The biokinetics of nanomaterials should be taken into account as that affects the dose present at a target site over time. The parameters determining the kinetic behaviour are not the same as the hazard-determining parameters. Furthermore, characteristics of nanomaterials change in the life-cycle, resulting in human exposure to different forms and doses of these nanomaterials. As information on the biokinetics and in situ characteristics of nanomaterials is essential but often lacking, efforts should be made to include these in testing strategies. Grouping nanomaterials will probably be of the most value to risk assessors when information on intrinsic characteristics, life-cycle, biokinetics and effects are all combined. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model.

    PubMed

    Hardiansyah, Deni; Attarwala, Ali Asgar; Kletting, Peter; Mottaghy, Felix M; Glatting, Gerhard

    2017-10-01

    To investigate the accuracy of predicted time-integrated activity coefficients (TIACs) in peptide-receptor radionuclide therapy (PRRT) using simulated dynamic PET data and a physiologically based pharmacokinetic (PBPK) model. PBPK parameters were estimated using biokinetic data of 15 patients after injection of (152±15)MBq of 111 In-DTPAOC (total peptide amount (5.78±0.25)nmol). True mathematical phantoms of patients (MPPs) were the PBPK model with the estimated parameters. Dynamic PET measurements were simulated as being done after bolus injection of 150MBq 68 Ga-DOTATATE using the true MPPs. Dynamic PET scans around 35min p.i. (P 1 ), 4h p.i. (P 2 ) and the combination of P 1 and P 2 (P 3 ) were simulated. Each measurement was simulated with four frames of 5min each and 2 bed positions. PBPK parameters were fitted to the PET data to derive the PET-predicted MPPs. Therapy was simulated assuming an infusion of 5.1GBq of 90 Y-DOTATATE over 30min in both true and PET-predicted MPPs. TIACs of simulated therapy were calculated, true MPPs (true TIACs) and predicted MPPs (predicted TIACs) followed by the calculation of variabilities v. For P 1 and P 2 the population variabilities of kidneys, liver and spleen were acceptable (v<10%). For the tumours and the remainders, the values were large (up to 25%). For P 3 , population variabilities for all organs including the remainder further improved, except that of the tumour (v>10%). Treatment planning of PRRT based on dynamic PET data seems possible for the kidneys, liver and spleen using a PBPK model and patient specific information. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. A plant-wide aqueous phase chemistry module describing pH variations and ion speciation/pairing in wastewater treatment process models.

    PubMed

    Flores-Alsina, Xavier; Kazadi Mbamba, Christian; Solon, Kimberly; Vrecko, Darko; Tait, Stephan; Batstone, Damien J; Jeppsson, Ulf; Gernaey, Krist V

    2015-11-15

    There is a growing interest within the Wastewater Treatment Plant (WWTP) modelling community to correctly describe physico-chemical processes after many years of mainly focusing on biokinetics. Indeed, future modelling needs, such as a plant-wide phosphorus (P) description, require a major, but unavoidable, additional degree of complexity when representing cationic/anionic behaviour in Activated Sludge (AS)/Anaerobic Digestion (AD) systems. In this paper, a plant-wide aqueous phase chemistry module describing pH variations plus ion speciation/pairing is presented and interfaced with industry standard models. The module accounts for extensive consideration of non-ideality, including ion activities instead of molar concentrations and complex ion pairing. The general equilibria are formulated as a set of Differential Algebraic Equations (DAEs) instead of Ordinary Differential Equations (ODEs) in order to reduce the overall stiffness of the system, thereby enhancing simulation speed. Additionally, a multi-dimensional version of the Newton-Raphson algorithm is applied to handle the existing multiple algebraic inter-dependencies. The latter is reinforced with the Simulated Annealing method to increase the robustness of the solver making the system not so dependent of the initial conditions. Simulation results show pH predictions when describing Biological Nutrient Removal (BNR) by the activated sludge models (ASM) 1, 2d and 3 comparing the performance of a nitrogen removal (WWTP1) and a combined nitrogen and phosphorus removal (WWTP2) treatment plant configuration under different anaerobic/anoxic/aerobic conditions. The same framework is implemented in the Benchmark Simulation Model No. 2 (BSM2) version of the Anaerobic Digestion Model No. 1 (ADM1) (WWTP3) as well, predicting pH values at different cationic/anionic loads. In this way, the general applicability/flexibility of the proposed approach is demonstrated, by implementing the aqueous phase chemistry module in some

  1. Lead remediation and changes in human lead exposure: some physiological and biokinetic dimensions.

    PubMed

    Mushak, Paul

    2003-02-15

    This paper presents a qualitative and quantitative analysis of the various aspects of lead remediation effectiveness with particular reference to human health risk assessment. One of the key elements of lead remediation efforts at such sites as those under the Superfund program deals with populations at elevated exposure and toxicity risk in the proximity of, or at, the site of remediation, especially remediation workers, workers at other tasks on sites that were remediated down to some action level of lead concentration in soils, and groups at risk in nearby communities. A second element has to do with how one measures or models lead exposure changes with special reference to baseline and post-remediation conditions. Various biomarkers of lead exposure can be employed, but their use requires detailed knowledge of what results using each means. The most commonly used approach is measurement of blood lead (Pb-B). Recognized limitations in the use of Pb-B has led to the use of predictive Pb exposure models, which are less vulnerable to the many behavioral, physiological, and environmental parameters that can distort isolated or 'single shot' Pb-B testings. A third aspect covered in this paper presents various physiological factors that affect the methods by which one evaluates Pb remediation effectiveness. Finally, this article offers an integrated look at how lead remediation actions directed at one lead source or pathway affect the total lead exposure picture for human populations at elevated lead exposure and toxicity risk.

  2. Inhaled particle deposition in unsteady-state respiratory flow at a numerically constructed model of the human larynx.

    PubMed

    Takano, Hiroshi; Nishida, Naohiro; Itoh, Masayuki; Hyo, Noboru; Majima, Yuichi

    2006-01-01

    To evaluate the clinical effectiveness of aerosol therapy for the lower and upper respiratory airways, particle deposition at the human laryngeal region has been analyzed with various unsteady-state respiratory flow-patterns. The flow profiles and trajectory of aerosol particles were calculated by 3-D thermo-fluid analysis of a finite volume method (FVM) with 8-CPUs parallel computational system. A reconstructed physical model of the real laryngeal airways was modified from 3-D CAM modeling function of Rhinoceros based on the images of Magnetic Resonance Imaging (MRI). By using 104 MRI images taken vertically and horizontally at intervals of 2 mm on the oral cavity and the pharynx-larynx respectively, 3-D physical model of the laryngeal airways was obtained. The numerical results of flow profile analyzed by the unsteady-state respiration model showed that vortex flow was occurred with time at near larynx, showing uniform flow profile in both the oral cavity and upper side of pharynx. The vortex was appeared at the anterior part of the epiglottis and downward of the vocal cord. However, it was confirmed that few particles deposit in the vocal cord. In these cases, the particle deposition was taken place mostly at the oral cavity and the oropharynx. On the other hand, the relationship between the particle deposition efficiency and the impaction in the laryngeal region was well agreement with the data sets of ICRP task group (1993) for the larynx deposition.

  3. MPC and ALI: their basis and their comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, W.E. Jr.; Watson, E.C.

    Radiation protection regulations in the United States have evolved from the recommendations of the International Commission on Radiological Protection (ICRP) and the National Council on Radiation Protection and Measurements (NCRP). In 1959, the ICRP issued Publication 2 which contained specific recommendations on dose rate limits, permissible body burdens, metabolic data for radionuclides, and maximum permissible concentrations (MPC) in air or water. Over the next 20 years, new information became available concerning the effects of radiation, the uptake and retention of radionuclides, and the radioactive decay schemes of parent radionuclides. To include this newer information, the ICRP issued Publication 30 inmore » 1978 to supersede Publication 2. One of the secondary limits defined in Publication 30 is the annual limit of intake (ALI). Radionuclide specific ALI values are intended to replace MPC values in determining whether or not ambient air and water concentrations are sufficiently low to maintain the dose to workers within accepted dose rate limits. In this paper, we discuss the derivation of MPC and ALI values, compare inhalation committed dose equivalent factors derived from ICRP Publications 2 and 30, and discuss the practical implications of using either MPC or ALI in determining compliance with occupational exposure limits. 6 references.« less

  4. Bio-kinetic energy harvesting using electroactive polymers

    NASA Astrophysics Data System (ADS)

    Slade, Jeremiah R.; Bowman, Jeremy; Kornbluh, Roy

    2012-06-01

    In hybrid vehicles, electric motors are used on each wheel to not only propel the car but also to decelerate the car by acting as generators. In the case of the human body, muscles spend about half of their time acting as a brake, absorbing energy, or doing what is known as negative work. Using dielectric elastomers it is possible to use the "braking" phases of walking to generate power without restricting or fatiguing the Warfighter. Infoscitex and SRI have developed and demonstrated methods for using electroactive polymers (EAPs) to tap into the negative work generated at the knee during the deceleration phase of the human gait cycle and convert it into electrical power that can be used to support wearable information systems, including display and communication technologies. The specific class of EAP that has been selected for these applications is termed dielectric elastomers. Because dielectric elastomers dissipate very little mechanical energy into heat, greater amounts of energy can be converted into electricity than by any other method. The long term vision of this concept is to have EAP energy harvesting cells located in components of the Warfighter ensemble, such as the boot uppers, knee pads and eventually even the clothing itself. By properly locating EAPs at these sites it will be possible to not only harvest power from the negative work phase but to actually reduce the amount of work done by the Warfighter's muscles during this phase, thereby reducing fatigue and minimizing the forces transmitted to the joints.

  5. CFD simulation of fluid dynamic and biokinetic processes within activated sludge reactors under intermittent aeration regime.

    PubMed

    Sánchez, F; Rey, H; Viedma, A; Nicolás-Pérez, F; Kaiser, A S; Martínez, M

    2018-08-01

    Due to the aeration system, biological reactors are the most energy-consuming facilities of convectional WWTPs. Many biological reactors work under intermittent aeration regime; the optimization of the aeration process (air diffuser layout, air flow rate per diffuser, aeration length …) is necessary to ensure an efficient performance; satisfying the effluent requirements with the minimum energy consumption. This work develops a CFD modelling of an activated sludge reactor (ASR) which works under intermittent aeration regime. The model considers the fluid dynamic and biological processes within the ASR. The biological simulation, which is transient, takes into account the intermittent aeration regime. The CFD modelling is employed for the selection of the aeration system of an ASR. Two different aeration configurations are simulated. The model evaluates the aeration power consumption necessary to satisfy the effluent requirements. An improvement of 2.8% in terms of energy consumption is achieved by modifying the air diffuser layout. An analysis of the influence of the air flow rate per diffuser on the ASR performance is carried out. The results show a reduction of 14.5% in the energy consumption of the aeration system when the air flow rate per diffuser is reduced. The model provides an insight into the aeration inefficiencies produced within ASRs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. The linear nonthreshold (LNT) model as used in radiation protection: an NCRP update.

    PubMed

    Boice, John D

    2017-10-01

    The linear nonthreshold (LNT) model has been used in radiation protection for over 40 years and has been hotly debated. It relies heavily on human epidemiology, with support from radiobiology. The scientific underpinnings include NCRP Report No. 136 ('Evaluation of the Linear-Nonthreshold Dose-Response Model for Ionizing Radiation'), UNSCEAR 2000, ICRP Publication 99 (2004) and the National Academies BEIR VII Report (2006). NCRP Scientific Committee 1-25 is reviewing recent epidemiologic studies focusing on dose-response models, including threshold, and the relevance to radiation protection. Recent studies after the BEIR VII Report are being critically reviewed and include atomic-bomb survivors, Mayak workers, atomic veterans, populations on the Techa River, U.S. radiological technologists, the U.S. Million Person Study, international workers (INWORKS), Chernobyl cleanup workers, children given computerized tomography scans, and tuberculosis-fluoroscopy patients. Methodologic limitations, dose uncertainties and statistical approaches (and modeling assumptions) are being systematically evaluated. The review of studies continues and will be published as an NCRP commentary in 2017. Most studies reviewed to date are consistent with a straight-line dose response but there are a few exceptions. In the past, the scientific consensus process has worked in providing practical and prudent guidance. So pragmatic judgment is anticipated. The evaluations are ongoing and the extensive NCRP review process has just begun, so no decisions or recommendations are in stone. The march of science requires a constant assessment of emerging evidence to provide an optimum, though not necessarily perfect, approach to radiation protection. Alternatives to the LNT model may be forthcoming, e.g. an approach that couples the best epidemiology with biologically-based models of carcinogenesis, focusing on chronic (not acute) exposure circumstances. Currently for the practical purposes of

  7. Estimates of internal-dose equivalent from inhalation and ingestion of selected radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, D.E.

    1982-01-01

    This report presents internal radiation dose conversion factors for radionuclides of interest in environmental assessments of nuclear fuel cycles. This volume provides an updated summary of estimates of committed dose equivalent for radionuclides considered in three previous Oak Ridge National Laboratory (ORNL) reports. Intakes by inhalation and ingestion are considered. The International Commission on Radiological Protection (ICRP) Task Group Lung Model has been used to simulate the deposition and retention of particulate matter in the respiratory tract. Results corresponding to activity median aerodynamic diameters (AMAD) of 0.3, 1.0, and 5.0 ..mu..m are given. The gastorintestinal (GI) tract has been representedmore » by a four-segment catenary model with exponential transfer of radioactivity from one segment to the next. Retention of radionuclides in systemic organs is characterized by linear combinations of decaying exponential functions, recommended in ICRP Publication 30. The first-year annual dose rate, maximum annual dose rate, and fifty-year dose commitment per microcurie intake of each radionuclide is given for selected target organs and the effective dose equivalent. These estimates include contributions from specified source organs plus the systemic activity residing in the rest of the body; cross irradiation due to penetrating radiations has been incorporated into these estimates. 15 references.« less

  8. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination.

    PubMed

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-21

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm -2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an

  9. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination

    NASA Astrophysics Data System (ADS)

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-01

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm-2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an

  10. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    PubMed

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  11. Core ethical values of radiological protection applied to Fukushima case: reflecting common morality and cultural diversities.

    PubMed

    Kurihara, Chieko; Cho, Kunwoo; Toohey, Richard E

    2016-12-01

    The International Commission on Radiological Protection (ICRP) has established Task Group 94 (TG94) to develop a publication to clarify the ethical foundations of the radiological protection system it recommends. This TG identified four core ethical values which structure the system: beneficence and non-maleficence, prudence, justice, and dignity. Since the ICRP is an international organization, its recommendations and guidance should be globally applicable and acceptable. Therefore, first this paper presents the basic principles of the ICRP radiological protection system and its core ethical values, along with a reflection on the variation of these values in Western and Eastern cultural traditions. Secondly, this paper reflects upon how these values can be applied in difficult ethical dilemmas as in the case of the emergency and post-accident phases of a nuclear power plant accident, using the Fukushima case to illustrate the challenges at stake. We found that the core ethical values underlying the ICRP system of radiological protection seem to be quite common throughout the world, although there are some variations among various cultural contexts. Especially we found that 'prudence' would call for somewhat different implementation in each cultural context, balancing and integrating sometime conflicting values, but always with objectives to achieve the well-being of people, which is itself the ultimate aim of the radiological protection system.

  12. A one-dimensional model for the propagation of transient pressure waves through the lung.

    PubMed

    Grimal, Quentin; Watzky, Alexandre; Naili, Salah

    2002-08-01

    The propagation of pressure waves in the lung has been investigated by many authors concerned with respiratory physiology, ultrasound medical techniques or thoracic impact injuries. In most of the theoretical studies, the lung has been modeled as an isotropic and homogeneous medium, and by using Hooke's constitutive law (see e.g. Ganesan et al. Respir. Physiol. 110 (1997) 19; Jahed et al. J. Appl. Physiol. 66 (1989) 2675; Grimal et al. C.R. Acad. Sci., Paris 329 (IIb) (2001) 655-662), or more elaborated material laws (see, e.g. Bush and Challener (Proceedings of the International Research Council on Biokinetics Impacts (IRCOBI), Bergish-gladbach, 1988); Stuhmiller et al. J. Trauma 28 (1988) S132; Yang and Wang, Finite element modeling of the human thorax. Web page: http://wwwils.nlm.nih.gov/research/visible/vhpconf98/AUTHORS/YANG/YANG.HTM.). The hypothesis of homogeneous medium may be inappropriate for certain problems. Because of its foam-like structure, the behavior of the lung-even if the air and the soft tissue are assumed to behave like linearly elastic materials-is susceptible to be frequency dependent. In the present study, the lung is viewed as a one-dimensional stack of air and soft tissue layers; wave propagation in such a stack can be investigated in an equivalent mass-spring chain (El-Raheb (J. Acoust. Soc. Am. 94 (1993) 172; Int. J. Solids Struct. 34 (1997) 2969), where the masses and springs, respectively, represent the alveolar walls and alveolar gas. Results are presented in the time and frequency domains. The frequency dependence (cutoff frequency, variations in phase velocity) of the lung model is found to be highly dependent on the mean alveolar size. We found that short pulses induced by high velocity impacts (bullet stopped by a bulletproof jacket) can be highly distorted during the propagation. The pressure differential between two alveoli is discussed as a possible injury criterion.

  13. The fate of calcium carbonate nanoparticles administered by oral route: absorption and their interaction with biological matrices.

    PubMed

    Lee, Jeong-A; Kim, Mi-Kyung; Kim, Hyoung-Mi; Lee, Jong Kwon; Jeong, Jayoung; Kim, Young-Rok; Oh, Jae-Min; Choi, Soo-Jin

    2015-01-01

    Orally administered particles rapidly interact with biological fluids containing proteins, enzymes, electrolytes, and other biomolecules to eventually form particles covered by a corona, and this corona potentially affects particle uptake, fate, absorption, distribution, and elimination in vivo. This study explored relationships between the biological interactions of calcium carbonate particles and their biokinetics. We examined the effects of food grade calcium carbonates of different particle size (nano [N-Cal] and bulk [B-Cal]: specific surface areas of 15.8 and 0.83 m(2)/g, respectively) on biological interactions in in vitro simulated physiological fluids, ex vivo biofluids, and in vivo in gastrointestinal fluid. Moreover, absorption and tissue distribution of calcium carbonates were evaluated following a single dose oral administration to rats. N-Cal interacted more with biomatrices than bulk materials in vitro and ex vivo, as evidenced by high fluorescence quenching ratios, but it did not interact more actively with biomatrices in vivo. Analysis of coronas revealed that immunoglobulin, apolipoprotein, thrombin, and fibrinogen, were the major corona proteins, regardless of particle size. A biokinetic study revealed that orally delivered N-Cal was more rapidly absorbed into the blood stream than B-Cal, but no significant differences were observed between the two in terms of absorption efficiencies or tissue distributions. Both calcium carbonates were primarily present as particulate forms in gastrointestinal fluids but enter the circulatory system in dissolved Ca(2+), although both types showed partial phase transformation to dicalcium phosphate dihydrate. Relatively low dissolution (about 4%), no remarkable protein-particle interaction, and the major particulate fate of calcium carbonate in vivo gastrointestinal fluids can explain its low oral absorption (about 4%) regardless of particle size. We conclude that calcium carbonate nanoparticles can act more

  14. Biokinetics of food additive silica nanoparticles and their interactions with food components.

    PubMed

    Lee, Jeong-A; Kim, Mi-Kyung; Song, Jae Ho; Jo, Mi-Rae; Yu, Jin; Kim, Kyoung-Min; Kim, Young-Rok; Oh, Jae-Min; Choi, Soo-Jin

    2017-02-01

    Nanomaterials have been widely utilized in the food industry in production, packaging, sensors, nutrient delivery systems, and food additives. However, research on the interactions between food-grade nanoparticles and biomolecules as well as their potential toxicity is limited. In the present study, the in vivo solubility, oral absorption, tissue distribution, and excretion kinetics of one of the most extensively used food additives, silica (SiO 2 ) were evaluated with respect to particle size (nano vs bulk) following single-dose oral administration to rats. Intestinal transport mechanism was investigated using a 3D culture system, in vitro model of human intestinal follicle-associated epithelium (FAE). The effect of the presence of food components, such as sugar and protein, on the oral absorption of nanoparticles was also evaluated with focus on their interactions. The results obtained demonstrated that the oral absorption of nanoparticles (3.94±0.38%) was greater than that of bulk materials (2.95±0.37%), possibly due to intestinal transport by microfold (M) cells. On the other hand, particle size was found to have no significant effect on in vivo dissolution property, biodistribution, or excretion kinetics. Oral absorption profile of silica nanoparticles was highly dependent on the presence of sugar or protein, showing rapid absorption rate in glucose, presumably due to their surface interaction on nanoparticles. These findings will be useful for predicting the potential toxicity of food-grade nanoparticles and for understanding biological interactions. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Guthrie; Klumpp, John A.; Melo, Dunstana

    Here, the pharmacokinetic equations of Pierson et al. describing the behavior of bromide in rat provide a general approach to the modeling of extracellular fluid (ECF). The movement of material into ECF spaces is rapid and is completely characterized by tissue volumes and vascular flow rates to and from a tissue, the volumes of the tissue, and the ECF associated with the tissue. Early-time measurements are needed to characterize ECF. Measurements of DTPA disappearance from plasma by Wedeking et al. are discussed as an example of such measurements. In any biokinetic model, the fastest transfer rates are not determinable withmore » the usual datasets, and if determined empirically, these rates will have very large and highly correlated uncertainties, so particular values of these rates, even though the model fits the available data, are not significant. A pharmacokinetic front-end provides values for these fast rates. An example of such a front-end for a 200–g rat is given.« less

  16. Pragmatic ethical basis for radiation protection in diagnostic radiology.

    PubMed

    Malone, Jim; Zölzer, Friedo

    2016-01-01

    Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years. The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations. A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic imaging. This system has the potential to be

  17. Pragmatic ethical basis for radiation protection in diagnostic radiology

    PubMed Central

    Zölzer, Friedo

    2016-01-01

    Objective: Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years. Methods: The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations. Results and conclusion: A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic

  18. Radiological protection in computed tomography and cone beam computed tomography.

    PubMed

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. 4D XCAT phantom for multimodality imaging research

    PubMed Central

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-01-01

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ‘‘Basic anatomical and physiological data for use in radiological protection: reference values,” ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce

  20. United States Transuranium and Uranium Registries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Filipy, R.E.; Dietert, S.E.

    1991-06-01

    This report summarizes the primary scientific activities of the United States Transuranium and Uranium Registries for the period October 1, 1989 through September 30, 1990. The Registries are parallel human tissue research programs devoted to the study of the actinide elements in humans. To date there have been 261 autopsy or surgical specimen donations, which include 11 whole bodies. The emphasis of the Registry was directed towards quality improvement and the development of a fully computerized data base that would incorporate not only the results of postmortem radiochemical analysis, but also medical and monitoring information obtained during life. Human subjectsmore » reviews were also completed. A three compartment biokinetic model for plutonium distribution is proposed. 2 tabs.« less

  1. The calculation of annual limits of intake for plutonium-239 in man using a bone model which allows for plutonium burial and recycling.

    PubMed

    Priest, N D; Hunt, B W

    1979-05-01

    Values of the annual limit of intake (ALI) for plutonium-239 in man have been calculated using committed dose equivalent limits as recommended by ICRP in Publication 26. The calculations were made using a multicompartment bone model which allows for plutonium burial and recycling in the skeleton. In one skeletal compartment, the growing surfaces of cortical bone, it is assumed that plutonium deposits are retained and are not subject to resorption or recycling. In the trabecular bone compartment plutonium is taken to be resorbed with either subsequent redeposition onto bone surfaces or retention in the bone marrow. ALIs for plutonium-239 have been calculated assuming a range of rates of bone accretion (0-32 micron yr-1), different amounts of plutonium retained in the marrow (0-60%) and a 20%, 45% or 70% deposition of plutonium in the skeleton from the blood. The calculations made using this bone model suggest that 750 Bq (20 nCi) is an appropriate ALI for the inhalation of class W and class Y plutonium compounds and that 830 kBq and 5 MBq (23 muCi and 136 muCi) are the appropriate ALIs for the ingestion of soluble and insoluble forms of plutonium respectively.

  2. A comparison of simple and realistic eye models for calculation of fluence to dose conversion coefficients in a broad parallel beam incident of protons

    NASA Astrophysics Data System (ADS)

    Sakhaee, Mahmoud; Vejdani-Noghreiyan, Alireza; Ebrahimi-Khankook, Atiyeh

    2015-01-01

    Radiation induced cataract has been demonstrated among people who are exposed to ionizing radiation. To evaluate the deterministic effects of ionizing radiation on the eye lens, several papers dealing with the eye lens dose have been published. ICRP Publication 103 states that the lens of the eye may be more radiosensitive than previously considered. Detailed investigation of the response of the lens showed that there are strong differences in sensitivity to ionizing radiation exposure with respect to cataract induction among the tissues of the lens of the eye. This motivated several groups to look deeper into issue of the dose to a sensitive cell population within the lens, especially for radiations with low energy penetrability that have steep dose gradients inside the lens. Two sophisticated mathematical models of the eye including the inner structure have been designed for the accurate dose estimation in recent years. This study focuses on the calculations of the absorbed doses of different parts of the eye using the stylized models located in UF-ORNL phantom and comparison with the data calculated with the reference computational phantom in a broad parallel beam incident of protons with energies between 20 MeV and 10 GeV. The obtained results indicate that the total lens absorbed doses of reference phantom has good compliance with those of the more sensitive regions of stylized models. However, total eye absorbed dose of these models greatly differ with each other for lower energies.

  3. Analysis of Mass Averaged Tissue Doses in CAM, CAF, MAX, and FAX

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Qualls, Garry D.; Clowdsley, Martha S.; Blattnig, Steve R.; Simonsen, Lisa C.; Walker, Steven A.; Singleterry, Robert C.

    2009-01-01

    To estimate astronaut health risk due to space radiation, one must have the ability to calculate exposure-related quantities averaged over specific organs and tissue types. In this study, we first examine the anatomical properties of the Computerized Anatomical Man (CAM), Computerized Anatomical Female (CAF), Male Adult voXel (MAX), and Female Adult voXel (FAX) models by comparing the masses of various tissues to the reference values specified by the International Commission on Radiological Protection (ICRP). Major discrepancies are found between the CAM and CAF tissue masses and the ICRP reference data for almost all of the tissues. We next examine the distribution of target points used with the deterministic transport code HZETRN to compute mass averaged exposure quantities. A numerical algorithm is used to generate multiple point distributions for many of the effective dose tissues identified in CAM, CAF, MAX, and FAX. It is concluded that the previously published CAM and CAF point distributions were under-sampled and that the set of point distributions presented here should be adequate for future studies involving CAM, CAF, MAX, or FAX. It is concluded that MAX and FAX are more accurate than CAM and CAF for space radiation analyses.

  4. Radiation protection issues on preparedness and response for a severe nuclear accident: experiences of the Fukushima accident.

    PubMed

    Homma, T; Takahara, S; Kimura, M; Kinase, S

    2015-06-01

    Radiation protection issues on preparedness and response for a severe nuclear accident are discussed in this paper based on the experiences following the accident at Fukushima Daiichi nuclear power plant. The criteria for use in nuclear emergencies in the Japanese emergency preparedness guide were based on the recommendations of International Commission of Radiological Protection (ICRP) Publications 60 and 63. Although the decision-making process for implementing protective actions relied heavily on computer-based predictive models prior to the accident, urgent protective actions, such as evacuation and sheltering, were implemented effectively based on the plant conditions. As there were no recommendations and criteria for long-term protective actions in the emergency preparedness guide, the recommendations of ICRP Publications 103, 109, and 111 were taken into consideration in determining the temporary relocation of inhabitants of heavily contaminated areas. These recommendations were very useful in deciding the emergency protective actions to take in the early stages of the Fukushima accident. However, some suggestions have been made for improving emergency preparedness and response in the early stages of a severe nuclear accident. © The Chartered Institution of Building Services Engineers 2014.

  5. Recent international regulations: low dose-low rate radiation protection and the demise of reason.

    PubMed

    Okkalides, Demetrios

    2008-01-01

    The radiation protection measures suggested by the International Committee for Radiation Protection (ICRP), national regulating bodies and experts, have been becoming ever more strict despite the decrease of any information supporting the existence of the Linear no Threshold model (LNT) and of any adverse effects of Low Dose Low Rate (LDLR) irradiation. This tendency arises from the disproportionate response of human society to hazards that are currently in fashion and is unreasonable. The 1 mSv/year dose limit for the public suggested by the ICRP corresponds to a 1/18,181 detriment-adjusted cancer risk and is much lower than other hazards that are faced by modern societies such as e.g. driving and smoking which carry corresponding rate risks of 1/2,100 and 1/2,000. Even worldwide deadly work accidents rate is higher at 1/ 8,065. Such excessive safety measures against minimal risks from man made radiation sources divert resources from very real and much greater hazards. In addition they undermine research and development of radiation technology and tend to subjugate science and the quest for understanding nature to phobic practices.

  6. The Incorporation of Radionuclides After Wounding by a “Dirty Bomb”: The Impact of Time for Decorporation Efficacy and a Model for Cases of Disseminated Fragmentation Wounds

    PubMed Central

    Rump, Alexis; Stricklin, Daniela; Lamkowski, Andreas; Eder, Stefan; Abend, Michael; Port, Matthias

    2017-01-01

    Objective: In the case of a terrorist attack by a “dirty bomb” there is a risk of internal contamination with radionuclides through inhalation and wounds. We studied the efficacy of a decorporation treatment depending on the initiation time and duration. Approach: Based on biokinetic models, we simulated the impact of different diethylenetriaminepentaacetic acid treatments on the committed effective dose after the incorporation of plutonium-239. Results: For the same level of radioactivity, the dose was higher after the fast absorption from the wound than after a slow invasion following inhalation. The impact of the treatment initiation time was particularly important in the case of the internal contamination through the wound. Ending the treatment at an early point in time was followed by an augmentation of radioactivity in the blood compartment, reflecting insufficient treatment duration. Treatment efficacy increased only marginally if extended over 90 days. Innovation and Conclusion: For plutonium-239, the committed effective dose and the impact of the treatment initiation time on therapeutic efficacy predominantly depend on the speed of invasion, i.e., the pathway and the physicochemical properties of the compounds involved. Thus, it is prudent to start decorporation therapy as soon as possible, as a loss of efficacy resulting from a delay in treatment initiation cannot be compensated later on. In the case of plutonium-239 incorporation, the treatment must be continued for several months. Multiple fragmentation wounds might be aggregated to a single wound model suited for internal dosimetry calculations by using the “rule of nine.” PMID:28116223

  7. A review of lung-to-blood absorption rates for radon progeny.

    PubMed

    Marsh, J W; Bailey, M R

    2013-12-01

    The International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model (HRTM) treats clearance of materials from the respiratory tract as a competitive process between absorption into blood and particle transport to the alimentary tract and lymphatics. The ICRP recommended default absorption rates for lead and polonium (Type M) in ICRP Publication 71 but stated that the values were not appropriate for short-lived radon progeny. This paper reviews and evaluates published data from volunteer and laboratory animal experiments to estimate the HRTM absorption parameter values for short-lived radon progeny. Animal studies showed that lead ions have two phases of absorption: ∼10 % absorbed with a half-time of ∼15 min, the rest with a half-time of ∼10 h. The studies also indicated that some of the lead ions were bound to respiratory tract components. Bound fractions, f(b), for lead were estimated from volunteer and animal studies and ranged from 0.2 to 0.8. Based on the evaluations of published data, the following HRTM absorption parameter values were derived for lead as a decay product of radon: f(r) = 0.1, s(r) = 100 d(-1), s(s) = 1.7 d(-1), f(b) = 0.5 and s(b) = 1.7 d(-1). Effective doses calculated assuming these absorption parameter values instead of a single absorption half-time of 10 h with no binding (as has generally been assumed) are only a few per cent higher. However, as there is some conflicting evidence on the absorption kinetics for radon progeny, dose calculations have been carried out for different sets of absorption parameter values derived from different studies. The results of these calculations are discussed.

  8. Radiological Risk Assessment of Capstone Depleted Uranium Aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, Fletcher; Roszell, Laurie E.; Daxon, Eric G.

    2009-02-26

    Assessment of the health risk from exposure to aerosols of depleted uranium (DU) is an important outcome of the Capstone aerosol studies that established exposure ranges to personnel in armored combat vehicles perforated by DU munitions. Although the radiation exposure from DU is low, there is concern that DU deposited in the body may increase cancer rates. Radiation doses to various organs of the body resulting from the inhalation of DU aerosols measured in the Capstone studies were calculated using International Commission on Radiological Protection (ICRP) models. Organs and tissues with the highest calculated committed equivalent 50-yr doses were lungmore » and extrathoracic tissues (nose and nasal passages, pharynx, larynx, mouth and thoracic lymph nodes). Doses to the bone surface and kidney were about 5 to 10% of the doses to the extrathoracic tissues. The methodologies of the ICRP International Steering Committee on Radiation Standards (ISCORS) were used for determining the whole body cancer risk. Organ-specific risks were estimated using ICRP and U.S. Environmental Protection Agency (EPA) methodologies. Risks for crewmembers and first responders were determined for selected scenarios based on the time interval of exposure and for vehicle and armor type. The lung was the organ with the highest cancer mortality risk, accounting for about 97% of the risks summed from all organs. The highest mean lifetime risk for lung cancer for the scenario with the longest exposure time interval (2 h) was 0.42%. This risk is low compared with the natural or background risk of 7.35%. These risks can be significantly reduced by using an existing ventilation system (if operable) and by reducing personnel time in the vehicle immediately after perforation.« less

  9. Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2009-01-13

    In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up

  10. Field and bioassay indicators for internal dose intervention therapy.

    PubMed

    Carbaugh, Eugene H

    2007-05-01

    Guidance is presented that is used at the U.S. Department of Energy Hanford Site to identify the potential need for medical intervention in response to intakes of radioactivity. The guidance, based on ICRP Publication 30 models and committed effective dose equivalents of 20 mSv and 200 mSv, is expressed as numerical workplace measurements and derived first-day bioassay results for large intakes. It is used by facility radiation protection staff and on-call dosimetry support staff during the first few days following an intake.

  11. Field and Bioassay Indicators for Internal Dose Intervention Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.

    2007-05-01

    Guidance is presented that is used at the U.S. Department of Energy Hanford Site to identify the potential need for medical intervention in response to intakes of radioactivity. The guidance, based on ICRP Publication 30 models and committed effective dose equivalents of 20 mSv and 200 mSv, is expressed as numerical workplace measurements and derived first-day bioassay results for large intakes. It is used by facility radiation protection staff and on-call dosimetry support staff during the first few days following an intake.

  12. Biodegradation at Dynamic Plume Fringes: Mixing Versus Reaction Control

    NASA Astrophysics Data System (ADS)

    Cirpka, O. A.; Eckert, D.; Griebler, C.; Haberer, C.; Kürzinger, P.; Bauer, R.; Mellage, A.

    2014-12-01

    Biodegradation of continuously emitted plumes is known to be most pronounced at the plume fringe, where mixing of contaminated water and ambient groundwater, containing dissolved electron acceptors, stimulates microbial activity. Under steady-state conditions, physical mixing of contaminant and electron acceptor by transverse dispersion was shown to be the major bottleneck for biodegradation, with plume lengths scaling inversely with the bulk transverse dispersivity in quasi two-dimensional settings. Under these conditions, the presence of suitable microbes is essential but the biokinetic parameters do not play an important role. When the location of the plume shifts (caused, e.g., by a fluctuating groundwater table), however, the bacteria are no more situated at the plume fringe and biomass growth, decay, activation and deactivation determine the time lag until the fringe-controlled steady state is approached again. During this time lag, degradation is incomplete. The objective of the presented study was to analyze to which extent flow and transport dynamics diminish effectiveness of fringe-controlled biodegradation and which microbial processes and related biokinetic parameters determine the system response in overall degradation to hydraulic fluctuations. We performed experiments in quasi-two-dimensional flow through microcosms on aerobic toluene degradation by Pseudomonas putida F1. Plume dynamics were simulated by vertical alteration of the toluene plume position and experimental results were analyzed by reactive-transport modeling. We found that, even after disappearance of the toluene plume for two weeks, the majority of microorganisms stayed attached to the sediment and regained their full biodegradation potential within two days after reappearance of the toluene plume. Our results underline that besides microbial growth and maintenance (often subsumed as "biomass decay") microbial dormancy (that is, change into a metabolically inactive state) and

  13. Do Cd, Cu, Ni, Pb, and Zn biomagnify in aquatic ecosystems?

    PubMed

    Cardwell, Rick D; Deforest, David K; Brix, Kevin V; Adams, William J

    2013-01-01

    In this review, we sought to assess from a study of the literature whether five in organic metals (viz., cadmium, copper, lead, nickel, and zinc) bio magnify in aquatic food webs. We also examined whether accumulated metals were toxic to consumers/predators and whether the essential metals (Cu and Zn and possibly Ni) behaved differently from non-essential ones (Cd and Pb). Biomagnification potential was indexed by the magnitude of single and multiple trophic transfers in food chains. In this analysis, we used three lines of evidence-laboratory empirical, biokinetic modeling, and field studies-to make assessments. Trophic transfer factors, calculatedfrom lab studies, field studies, and biokinetic modeling, were generally congruent.Results indicated that Cd, Cu, Pb, and Zn generally do not biomagnify in food chains consisting of primary producers, macro invertebrate consumers, and fish occupying TL 3 and higher. However, bio magnification of Zn (TTFs of 1-2) is possible for circumstances in which dietary Zn concentrations are below those required for metabolism. Cd, Cu, Ni, and Zn may biomagnify in specific marine food chains consisting of bivalves, herbivorous gastropods, and barnacles at TL2 and carnivorous gastropods at TL3. There was an inverse relationship between TTF and exposure concentration for Cd, Cu, Pb, and Zn, a finding that is consistent with previous reviews of bioconcentration factors and bioaccumulation factors for metals. Our analysis also failed to demonstrate a relationship between the magnitude of TTFsand dietary toxicity to consumer organisms. Consequently, we conclude that TTFs for the metals examined are not an inherently useful predictor of potential hazard(i.e., toxic potential) to aquatic organisms. This review identified several uncertainties or data gaps, such as the relatively limited data available for nickel, reliance upon highly structured food chains in laboratory studies compared to the unstructured food webs found in nature, and

  14. Mathematical model for carbon dioxide evolution from the thermophilic composting of synthetic food wastes made of dog food

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, J.I.; Tsai, J.J.; Wu, K.H.

    2005-07-01

    The impacts of the aeration and the agitation on the composting process of synthetic food wastes made of dog food were studied in a laboratory-scale reactor. Two major peaks of CO{sub 2} evolution rate were observed. Each peak represented an independent stage of composting associated with the activities of thermophilic bacteria. CO{sub 2} evolutions known to correlate well with microbial activities and reactor temperatures were fitted successfully to a modified Gompertz equation, which incorporated three biokinetic parameters, namely, CO{sub 2} evolution potential, specific CO{sub 2} evolution rate, and lag phase time. No parameters that describe the impact of operating variablesmore » are involved. The model is only valid for the specified experimental conditions and may look different with others. The effects of operating parameters such as aeration and agitation were studied statistically with multivariate regression technique. Contour plots were constructed using regression equations for the examination of the dependence of CO{sub 2} evolution potentials on aeration and agitation. In the first stage, a maximum CO{sub 2} evolution potential was found when the aeration rate and the agitation parameter were set at 1.75 l/kg solids-min and 0.35, respectively. In the second stage, a maximum existed when the aeration rate and the agitation parameter were set at 1.8 l/kg solids-min and 0.5, respectively. The methods presented here can also be applied for the optimization of large-scale composting facilities that are operated differently and take longer time.« less

  15. Updated Mortality Analysis of Radiation Workers at Rocketdyne (Atomics International), 1948-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boice Jr JD, Colen SS, Mumma MT, Ellis ED, Eckerman DF, Leggett RW, Boecker BB, Brill B, Henderson BE

    Updated analyses of mortality data are presented on 46,970 workers employed 1948-1999 at Rocketdyne (Atomics International). Overall, 5,801 workers were involved in radiation activities, including 2,232 who were monitored for intakes of radionuclides, and 41,169 workers were engaged in rocket testing or other non-radiation activities. The worker population is unique in that lifetime occupational doses from all places of employment were sought, updated and incorporated into the analyses. Further, radiation doses from intakes of 14 different radionuclides were calculated for 16 organs or tissues using biokinetic models of the International Commission on Radiation Protection (ICRP). Because only negligible exposures weremore » received by the 247 workers monitored for radiation activities after 1999, the mean dose from external radiation remained essentially the same at 13.5 mSv (maximum 1 Sv) as reported previously, as did the mean lung dose from external and internal radiation combined at 19.0 mSv (maximum 3.6 Sv). An additional 9 years of follow-up, from December 31,1999 through 2008, increased the person-years of observation for the radiation workers by 21.7% to 196,674 (mean 33.9 years) and the number of cancer deaths by 50% to 684. Analyses included external comparisons with the general population and the computation of standardized mortality ratios (SMRs) and internal comparisons using proportional hazards models and the computation of relative risks (RRs). A low SMR for all causes of death (SMR 0.82; 95% CI 0.78-0.85) continued to indicate that the Rocketdyne radiation workers were healthier than the general population and were less likely to die. The SMRs for all cancers taken together (SMR 0.88; 95% CI 0.81-0.95), lung cancer (SMR 0.87; 95% CI 0.76-1.00) and leukemia other than chronic lymphocytic leukemia (CLL) (SMR 1.04; 95% 0.67-1.53) were not significantly elevated. Cox regression analyses revealed no significant dose-response trends for any cancer

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parra, Pamela Ochoa, E-mail: lapochoap@unal.edu.co; Veloza, Stella

    The radiotracer called {sup 68}Ga-labelled Glu-urea-Lys(Ahx)-HBED-CC ([68Ga]Ga-PSMA-HBED-CC) is a novel radiophar-maceutical for the detection of prostate cancer lesions by positron emission tomography (PET) imaging. Setting up a cost-effective manual synthesis of this radiotracer and making its clinical translation in Colombia will require two important elements: the evaluation of the procedure to yield a consistent product, meeting standards of radio-chemical purity and low toxicity and then, the evaluation of the radiation dosimetry. In this paper a protocol to extrapolate the biokinetic model made in normal mice to humans by using the computer software for internal dose assessment OLINDA/EXM® is presented asmore » an accurate and standardized method for the calculation of radiation dosimetry estimates.« less

  17. Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models

    NASA Astrophysics Data System (ADS)

    Lee, Choonsik; Lodwick, Daniel; Hasenauer, Deanna; Williams, Jonathan L.; Lee, Choonik; Bolch, Wesley E.

    2007-07-01

    phantom is performed in three steps: polygonization of the voxel phantom, organ modeling via NURBS surfaces and phantom voxelization. Two 3D graphic tools, 3D-DOCTOR™ and Rhinoceros™, were utilized to polygonize the newborn voxel phantom and generate NURBS surfaces, while an in-house MATLAB™ code was used to voxelize the resulting NURBS model into a final computational phantom ready for use in Monte Carlo radiation transport calculations. A total of 126 anatomical organ and tissue models, including 38 skeletal sites and 31 cartilage sites, were described within the hybrid phantom using either NURBS or polygon surfaces. A male hybrid newborn phantom was constructed following the development of the female phantom through the replacement of female-specific organs with male-specific organs. The outer body contour and internal anatomy of the NURBS-based phantoms were adjusted to match anthropometric and reference newborn data reported by the International Commission on Radiological Protection in their Publication 89. The voxelization process was designed to accurately convert NURBS models to a voxel phantom with minimum volumetric change. A sensitivity study was additionally performed to better understand how the meshing tolerance and voxel resolution would affect volumetric changes between the hybrid-NURBS and hybrid-voxel phantoms. The male and female hybrid-NURBS phantoms were constructed in a manner so that all internal organs approached their ICRP reference masses to within 1%, with the exception of the skin (-6.5% relative error) and brain (-15.4% relative error). Both hybrid-voxel phantoms were constructed with an isotropic voxel resolution of 0.663 mm—equivalent to the ICRP 89 reference thickness of the newborn skin (dermis and epidermis). Hybrid-NURBS phantoms used to create their voxel counterpart retain the non-uniform scalability of stylized phantoms, while maintaining the anatomic realism of segmented voxel phantoms with respect to organ shape, depth and

  18. AGE-DEPENDENT INHALATION DOSE DUE TO EXPOSURE OF SHORT LIVED PROGENY OF RADON AND THORON FOR DIFFERENT AGE GROUPS IN JAMMU & KASHMIR, HIMALAYAS.

    PubMed

    Sharma, Sumit; Kumar, Ajay; Mehra, Rohit

    2018-05-16

    Dosimetric approach is used in this study for the assessment of doses due to inhalation of short lived radon/thoron progeny to the inhabitants of Udhampur district of Jammu & Kashmir. This paper also presents the activity concentrations and unattached fraction of radon and thoron progeny. The observed annual concentration of attached and unattached 222Rn and 220Rn progeny has been found to vary from 8 to 32 and 0.09 to 14 Bq/m3, 0.75 to 3.16 and 0.01 to 1.13 Bq/m3, respectively. The inhalation doses from radon progeny to different body organs of different age groups have been calculated by using the age dependent biokinetic model. The attachment rate of 222Rn and indoor aerosol concentration of 222Rn and 220Rn have been estimated and their relation between them has also been studied. The dose conversion factor for mouth and nasal breathing to different exposure conditions has been obtained from Porstendorfer model.

  19. Process optimization and analysis of product inhibition kinetics of crude glycerol fermentation for 1,3-Dihydroxyacetone production.

    PubMed

    Dikshit, Pritam Kumar; Padhi, Susant Kumar; Moholkar, Vijayanand S

    2017-11-01

    In present study, statistical optimization of biodiesel-derived crude glycerol fermentation to DHA by immobilized G. oxydans cells over polyurethane foam is reported. Effect of DHA (product) inhibition on crude glycerol fermentation was analyzed using conventional biokinetic models and new model that accounts for both substrate and product inhibition. Optimum values of fermentation parameters were: pH=4.7, temperature=31°C, initial substrate concentration=20g/L. At optimum conditions, DHA yield was 89% (17.83g/L). Effect of product inhibition on fermentation was trivial for DHA concentrations ≤30g/L. At higher concentrations (≥50g/L), kinetics and yield of fermentation showed marked reduction with sharp drop in V max and K S values. Inhibition effect was more pronounced for immobilized cells due to restricted transport of fermentation mixture across polyurethane foam. Retention of fermentation mixture in immobilized matrix resulted in higher localized DHA concentration that possibly enhanced inhibition effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9

    NASA Astrophysics Data System (ADS)

    Xu, X. George; Taranenko, Valery; Zhang, Juying; Shi, Chengyu

    2007-12-01

    Fetuses are extremely radiosensitive and the protection of pregnant females against ionizing radiation is of particular interest in many health and medical physics applications. Existing models of pregnant females relied on simplified anatomical shapes or partial-body images of low resolutions. This paper reviews two general types of solid geometry modeling: constructive solid geometry (CSG) and boundary representation (BREP). It presents in detail a project to adopt the BREP modeling approach to systematically design whole-body radiation dosimetry models: a pregnant female and her fetus at the ends of three gestational periods of 3, 6 and 9 months. Based on previously published CT images of a 7-month pregnant female, the VIP-Man model and mesh organ models, this new set of pregnant female models was constructed using 3D surface modeling technologies instead of voxels. The organ masses were adjusted to agree with the reference data provided by the International Commission on Radiological Protection (ICRP) and previously published papers within 0.5%. The models were then voxelized for the purpose of performing dose calculations in identically implemented EGS4 and MCNPX Monte Carlo codes. The agreements of the fetal doses obtained from these two codes for this set of models were found to be within 2% for the majority of the external photon irradiation geometries of AP, PA, LAT, ROT and ISO at various energies. It is concluded that the so-called RPI-P3, RPI-P6 and RPI-P9 models have been reliably defined for Monte Carlo calculations. The paper also discusses the needs for future research and the possibility for the BREP method to become a major tool in the anatomical modeling for radiation dosimetry.

  1. Development of PIMAL: Mathematical Phantom with Moving Arms and Legs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akkurt, Hatice; Eckerman, Keith F.

    2007-05-01

    The computational model of the human anatomy (phantom) has gone through many revisions since its initial development in the 1970s. The computational phantom model currently used by the Nuclear Regulatory Commission (NRC) is based on a model published in 1974. Hence, the phantom model used by the NRC staff was missing some organs (e.g., neck, esophagus) and tissues. Further, locations of some organs were inappropriate (e.g., thyroid).Moreover, all the computational phantoms were assumed to be in the vertical-upright position. However, many occupational radiation exposures occur with the worker in other positions. In the first phase of this work, updates onmore » the computational phantom models were reviewed and a revised phantom model, which includes the updates for the relevant organs and compositions, was identified. This revised model was adopted as the starting point for this development work, and hence a series of radiation transport computations, using the Monte Carlo code MCNP5, was performed. The computational results were compared against values reported by the International Commission on Radiation Protection (ICRP) in Publication 74. For some of the organs (e.g., thyroid), there were discrepancies between the computed values and the results reported in ICRP-74. The reasons behind these discrepancies have been investigated and are discussed in this report.Additionally, sensitivity computations were performed to determine the sensitivity of the organ doses for certain parameters, including composition and cross sections used in the simulations. To assess the dose for more realistic exposure configurations, the phantom model was revised to enable flexible positioning of the arms and legs. Furthermore, to reduce the user time for analyses, a graphical user interface (GUI) was developed. The GUI can be used to visualize the positioning of the arms and legs as desired posture is achieved to generate the input file, invoke the computations, and extract the

  2. The fate of calcium carbonate nanoparticles administered by oral route: absorption and their interaction with biological matrices

    PubMed Central

    Lee, Jeong-A; Kim, Mi-Kyung; Kim, Hyoung-Mi; Lee, Jong Kwon; Jeong, Jayoung; Kim, Young-Rok; Oh, Jae-Min; Choi, Soo-Jin

    2015-01-01

    Background Orally administered particles rapidly interact with biological fluids containing proteins, enzymes, electrolytes, and other biomolecules to eventually form particles covered by a corona, and this corona potentially affects particle uptake, fate, absorption, distribution, and elimination in vivo. This study explored relationships between the biological interactions of calcium carbonate particles and their biokinetics. Methods We examined the effects of food grade calcium carbonates of different particle size (nano [N-Cal] and bulk [B-Cal]: specific surface areas of 15.8 and 0.83 m2/g, respectively) on biological interactions in in vitro simulated physiological fluids, ex vivo biofluids, and in vivo in gastrointestinal fluid. Moreover, absorption and tissue distribution of calcium carbonates were evaluated following a single dose oral administration to rats. Results N-Cal interacted more with biomatrices than bulk materials in vitro and ex vivo, as evidenced by high fluorescence quenching ratios, but it did not interact more actively with biomatrices in vivo. Analysis of coronas revealed that immunoglobulin, apolipoprotein, thrombin, and fibrinogen, were the major corona proteins, regardless of particle size. A biokinetic study revealed that orally delivered N-Cal was more rapidly absorbed into the blood stream than B-Cal, but no significant differences were observed between the two in terms of absorption efficiencies or tissue distributions. Both calcium carbonates were primarily present as particulate forms in gastrointestinal fluids but enter the circulatory system in dissolved Ca2+, although both types showed partial phase transformation to dicalcium phosphate dihydrate. Relatively low dissolution (about 4%), no remarkable protein–particle interaction, and the major particulate fate of calcium carbonate in vivo gastrointestinal fluids can explain its low oral absorption (about 4%) regardless of particle size. Conclusion We conclude that calcium

  3. Dose estimation of eye lens for interventional procedures in diagnosis

    NASA Astrophysics Data System (ADS)

    Liu, Yu-Rong; Huang, Chia-Yu; Hsu, Ching-Han; Hsu, Fang-Yuh

    2017-11-01

    The International Commission on Radiological Protection (ICRP) recommended that the equivalent dose limit for the lens of the eye be decreased from 150 mSv/y (ICRP, 2007) to 20 mSv/y averaged over five years (ICRP, 2011). How to accurately measure the eye-lens dose has, therefore, been an issue of interest recently. Interventional radiologists are at a higher risk of radiation-induced eye injury, such as cataracts, than all other occupational radiation workers. The main objective of this study is to investigate the relationship between the doses to the eye lenses of interventional radiologists measured by different commercial eye-lens dosimeters. This study measured a reference eye-lens dose, which involved placing thermoluminescent dosimeter (TLD) chips at the surface of the eye of the Rando Phantom, and the TLD chips were covered by a 3-mm-thick tissue-equivalent bolus. Commercial eye-lens dosimeters, such as a headband dosimeter and standard personnel dose badges, were placed at the positions recommended by the manufacturers. The results show that the personnel dose badge is not an appropriate dosimeter for evaluating eye-lens dose. Dose deviations for different dosimeters are discussed and presented in this study.

  4. Availability of nuclear decay data in electronic form, including beta spectra not previously published

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.

    1994-10-01

    The unabridged data used in preparing ICRP Publication 38 (1983) and a monograph of the Medical Internal Radiation Dose (MIRD) Committee are now available in electronic form. The {open_quotes}ICRP38 collection{close_quotes} contains data on the energies and intensities of radiations emitted by 825 radionuclides (those in ICRP Publication 38 plus 13 from the MIRD monograph), and the {open_quotes}MIRD collection{close_quotes} contains data on 242 radionuclides. Each collection consists of a radiations data file and a beta spectra data file. The radiations data file contains the complete listing of the emitted radiations, their types, mean or unique energies, and absolute intensities for eachmore » radionuclide, the probability that a beta particle will be emitted with kinetic energies defined by a standard energy grid. Although summary information from the radiation data files has been published, neither the unabridged data nor the beta spectra have been published. These data files and a data extraction utility, which runs on a personal computer, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory. 13 refs., 1 fig., 6 tabs.« less

  5. An improved MCNP version of the NORMAN voxel phantom for dosimetry studies.

    PubMed

    Ferrari, P; Gualdrini, G

    2005-09-21

    In recent years voxel phantoms have been developed on the basis of tomographic data of real individuals allowing new sets of conversion coefficients to be calculated for effective dose. Progress in radiation studies brought ICRP to revise its recommendations and a new report, already circulated in draft form, is expected to change the actual effective dose evaluation method. In the present paper the voxel phantom NORMAN developed at HPA, formerly NRPB, was employed with MCNP Monte Carlo code. A modified version of the phantom, NORMAN-05, was developed to take into account the new set of tissues and weighting factors proposed in the cited ICRP draft. Air kerma to organ equivalent dose and effective dose conversion coefficients for antero-posterior and postero-anterior parallel photon beam irradiations, from 20 keV to 10 MeV, have been calculated and compared with data obtained in other laboratories using different numerical phantoms. Obtained results are in good agreement with published data with some differences for the effective dose calculated employing the proposed new tissue weighting factors set in comparison with previous evaluations based on the ICRP 60 report.

  6. Estimation of absorbed fraction to the anterior nose from inhaled beta emitters

    NASA Astrophysics Data System (ADS)

    Moussa, Hanna Moussa

    2000-08-01

    The main purpose of this research is to introduce a new and more realistic geometry for the anterior nose region (ET1) as an alternative to the one provided in ICRP Publication 66. For a more accurate estimation of electron absorbed fraction (AF) to the nuclei of basal cells in the ET 1 region, the proposed new geometry (frustum of a cone) replaces the cylinder geometry, which was used in ICRP 66. Since the electron absorbed fraction (AF) data in ICRP 66 are calculated based on the nose size for an adult Caucasian male, a second purpose of this research is to investigate how the nose size (different ethnic groups) and nose tissue composition (male, female and adolescent), affects the electron absorbed fraction values. The third aim of this research is to develop a Monte Carlo program to estimate the electron energies that emerge from the surface of spherical dust particles. Given that electrons can be located anywhere between the center and the surface of the sphere, we vary the sphere radius from 0.5 to 50 μm and investigate the effects of self-absorption on the emitted electron energies and absorbed fraction.

  7. Medical and occupational dose reduction in pediatric barium meal procedures

    NASA Astrophysics Data System (ADS)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Ledesma, J. A.; Legnani, A.; Bunick, A. P.; Sauzen, J.; Yagui, A.; Vosiak, P.

    2017-11-01

    Doses received in pediatric Barium Meal procedure can be rather high. It is possible to reduce dose values following the recommendations of the European Communities (EC) and the International Commission on Radiological Protection (ICRP). In the present work, the modifications of radiographic techniques made in a Brazilian hospital according to the EC and the ICRP recommendations and their influence on medical and occupational exposure are reported. The procedures of 49 patients before and 44 after the optimization were studied and air kerma-area product (PK,A) values and the effective doses were evaluated. The occupational equivalent doses were measured next to the eyes, under the thyroid shield and on each hand of both professionals who remained inside the examination room. The implemented modifications reduced by 70% and 60% the PK,A and the patient effective dose, respectively. The obtained dose values are lower than approximately 75% of the results from similar studies. The occupational annual equivalent doses for all studied organs became lower than the limits set by the ICRP. The equivalent doses in one examination were on average below than 75% of similar studies.

  8. History and Organizations for Radiological Protection.

    PubMed

    Kang, Keon Wook

    2016-02-01

    International Commission on Radiological Protection (ICRP), an independent international organization established in 1925, develops, maintains, and elaborates radiological protection standards, legislation, and guidelines. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) provides scientific evidence. World Health Organization (WHO) and International Atomic Energy Agency (IAEA) utilise the ICRP recommendations to implement radiation protection in practice. Finally, radiation protection agencies in each country adopt the policies, and adapt them to each situation. In Korea, Nuclear Safety and Security Commission is the governmental body for nuclear safety regulation and Korea Institute of Nuclear Safety is a public organization for technical support and R&D in nuclear safety and radiation protection.

  9. Analysis methodology and development of a statistical tool for biodistribution data from internal contamination with actinides.

    PubMed

    Lamart, Stephanie; Griffiths, Nina M; Tchitchek, Nicolas; Angulo, Jaime F; Van der Meeren, Anne

    2017-03-01

    The aim of this work was to develop a computational tool that integrates several statistical analysis features for biodistribution data from internal contamination experiments. These data represent actinide levels in biological compartments as a function of time and are derived from activity measurements in tissues and excreta. These experiments aim at assessing the influence of different contamination conditions (e.g. intake route or radioelement) on the biological behavior of the contaminant. The ever increasing number of datasets and diversity of experimental conditions make the handling and analysis of biodistribution data difficult. This work sought to facilitate the statistical analysis of a large number of datasets and the comparison of results from diverse experimental conditions. Functional modules were developed using the open-source programming language R to facilitate specific operations: descriptive statistics, visual comparison, curve fitting, and implementation of biokinetic models. In addition, the structure of the datasets was harmonized using the same table format. Analysis outputs can be written in text files and updated data can be written in the consistent table format. Hence, a data repository is built progressively, which is essential for the optimal use of animal data. Graphical representations can be automatically generated and saved as image files. The resulting computational tool was applied using data derived from wound contamination experiments conducted under different conditions. In facilitating biodistribution data handling and statistical analyses, this computational tool ensures faster analyses and a better reproducibility compared with the use of multiple office software applications. Furthermore, re-analysis of archival data and comparison of data from different sources is made much easier. Hence this tool will help to understand better the influence of contamination characteristics on actinide biokinetics. Our approach can aid

  10. Modeling The Skeleton Weight of an Adult Caucasian Man.

    PubMed

    Avtandilashvili, Maia; Tolmachev, Sergei Y

    2018-05-17

    biokinetic modeling of U.S. Transuranium and Uranium Registries partial-body donation cases.

  11. Characterization and validation of the thorax phantom Lungman for dose assessment in chest radiography optimization studies.

    PubMed

    Rodríguez Pérez, Sunay; Marshall, Nicholas William; Struelens, Lara; Bosmans, Hilde

    2018-01-01

    This work concerns the validation of the Kyoto-Kagaku thorax anthropomorphic phantom Lungman for use in chest radiography optimization. The equivalence in terms of polymethyl methacrylate (PMMA) was established for the lung and mediastinum regions of the phantom. Patient chest examination data acquired under automatic exposure control were collated over a 2-year period for a standard x-ray room. Parameters surveyed included exposure index, air kerma area product, and exposure time, which were compared with Lungman values. Finally, a voxel model was developed by segmenting computed tomography images of the phantom and implemented in PENELOPE/penEasy Monte Carlo code to compare phantom tissue-equivalent materials with materials from ICRP Publication 89 in terms of organ dose. PMMA equivalence varied depending on tube voltage, from 9.5 to 10.0 cm and from 13.5 to 13.7 cm, for the lungs and mediastinum regions, respectively. For the survey, close agreement was found between the phantom and the patients' median values (deviations lay between 8% and 14%). Differences in lung doses, an important organ for optimization in chest radiography, were below 13% when comparing the use of phantom tissue-equivalent materials versus ICRP materials. The study confirms the value of the Lungman for chest optimization studies.

  12. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images.

    PubMed

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity.

  13. Modelling growth of Penicillium expansum and Aspergillus niger at constant and fluctuating temperature conditions.

    PubMed

    Gougouli, Maria; Koutsoumanis, Konstantinos P

    2010-06-15

    The growth of Penicillium expansum and Aspergillus niger, isolated from yogurt production environment, was investigated on malt extract agar with pH=4.2 and a(w)=0.997, simulating yogurt, at isothermal conditions ranging from -1.3 to 35 degrees C and from 5 to 42.3 degrees C, respectively. The growth rate (mu) and (apparent) lag time (lambda) of the mycelium growth were modelled as a function of temperature using a Cardinal Model with Inflection (CMI). The results showed that the CMI can describe successfully the effect of temperature on fungal growth within the entire biokinetic range for both isolates. The estimated values of the CMI for mu were T(min)=-5.74 degrees C, T(max)=30.97 degrees C, T(opt)=22.08 degrees C and mu(opt)=0.221 mm/h for P. expansum and T(min)=10.13 degrees C, T(max)=43.13 degrees C, T(opt)=31.44 degrees C, and mu(opt)=0.840 mm/h for A. niger. The cardinal values for lambda were very close to the respective values for mu indicating similar temperature dependence of the growth rate and the lag time of the mycelium growth. The developed models were further validated under fluctuating temperature conditions using various dynamic temperature scenarios. The time-temperature conditions studied included single temperature shifts before or after the end of the lag time and continuous periodic temperature fluctuations. The prediction of growth at changing temperature was based on the assumption that after a temperature shift the growth rate is adopted instantaneously to the new temperature, while the lag time was predicted using a cumulative lag approach. The results showed that when the temperature shifts occurred before the end of the lag, they did not cause any significant additional lag and the observed total lag was very close to the cumulative lag predicted by the model. In experiments with temperature shifts after the end of the lag time, accurate predictions were obtained when the temperature profile included temperatures which were inside the

  14. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation.

    PubMed

    Qiu, Rui; Li, Junli; Zhang, Zhan; Liu, Liye; Bi, Lei; Ren, Li

    2009-02-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface.

  15. The internal dosimetry of Rubidium-82 based on dynamic PET/CT imaging in humans

    NASA Astrophysics Data System (ADS)

    Hunter, Chad R.

    Rubidium-82 (Rb-82) is a useful blood flow tracer, and has become important in recent years due to the shutdown of the Chalk River reactor. Published effective dose estimates for Rb-82 vary widely, and as yet no comprehensive study in man has been conducted with PET/CT, and no effective dose estimates for Rb-82 during pharmacological stress testing has been published. 30 subjects were recruited for rest, and 25 subjects were recruited for stress. The subjects consisted of both cardiac patients and normal subjects. For rest, a total of 283 organs were measured across 60 scans. For stress, a total of 171 organs were measured across 25 scans. Effective dose estimates were calculated using the ICRP 60, 80, and 103 tissue weighting factors. Relative differences between this study and the published in-vivo estimates showed agreement for the lungs. Relative differences between this study and the blood flow models showed differences> 5 times in the thyroid contribution to the effective dose demonstrating a limitation in these models. Comparisons between rest and stress effective dose estimates revealed no significant difference. The average 'adult' effective dose for Rb-82 was found to be 0.00084+/-0.00018 mSv/MBq. The highest dose organs were the lungs, kidneys and stomach wall. These dose estimates for Rb-82 are the first to be measured directly with PET/CT in humans, and are 4 times lower than previous ICRP 60 values based on a theoretical blood flow model. The total adult effective dose from a typical Rb-82 study including CT for attenuation correction and potential Sr-85 breakthrough is 1.5 +/- 0.4 mSv.

  16. Dose conversion coefficients for photon exposure of the human eye lens.

    PubMed

    Behrens, R; Dietze, G

    2011-01-21

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  17. Development of Intake Retention, and Excretion Fractions used in Bioassay Programs for Metallic Nanoparticle Aerosols Produced in Modern Munitions Development

    DTIC Science & Technology

    2014-03-01

    potential toxicological effects of tungsten-compounds are often attributed to the presence of cobalt and or chromium which are frequently contained in...rat test subjects.4 These claims were later put in doubt because of the substantial presents of chromium and cobalt in the tungsten alloy. Very little...biokinetics of aluminum follow similar trends as other trivalent metals. Of specific importance to this work, Priest made the assertion that

  18. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images*

    PubMed Central

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    Objective This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. Materials and Methods A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. Results With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. Conclusion The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity. PMID:25741101

  19. Biokinetics of /sup 237/Np in mussels and shrimp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guary, J.C.; Fowler, S.W.

    1977-01-01

    Neptunium-237 kinetics were studied in marine shrimp and mussels using a thick source alpha counting technique. Bioaccumulation of /sup 237/Np from water was relatively slow in both species, reaching whole body concentration factors of only 15 to 20 after three months. Surface adsorption was implicated in the initial uptake. Both uptake and loss of the radioisotope were not significantly affected by temperature; this may be a reflection of the physical nature of the uptake. By virtue of the large amounts of accumulated /sup 237/Np associated with the exoskeleton of shrimp, molting will play an important role in the biogeochemical cyclingmore » of this transuranic in the marine environment. Rapid growth of organisms like mussels acts to reduce the /sup 237/Np concentration in tissues during a period of decontamination.« less

  20. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT.

    PubMed

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W

    2012-04-01

    To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. ICRP Publication 125: Radiological Protection in Security Screening.

    PubMed

    Cool, D A; Lazo, E; Tattersall, P; Simeonov, G; Niu, S

    2014-07-01

    The use of technologies to provide security screening for individuals and objects has been increasing rapidly, in keeping with the significant increase in security concerns worldwide. Within the spectrum of technologies, the use of ionizing radiation to provide backscatter and transmission screening capabilities has also increased. The Commission has previously made a number of statements related to the general topic of deliberate exposures of individuals in non-medical settings. This report provides advice on how the radiological protection principles recommended by the Commission should be applied within the context of security screening. More specifically, the principles of justification, optimisation of protection, and dose limitation for planned exposure situations are directly applicable to the use of ionising radiation in security screening. In addition, several specific topics are considered in this report, including the situation in which individuals may be exposed because they are concealed (‘stowaways’) in a cargo container or conveyance that may be subject to screening. The Commission continues to recommend that careful justification of screening should be considered before decisions are made to employ the technology. If a decision is made that its use is justified, the framework for protection as a planned exposure situation should be employed, including optimization of protection with the use of dose constraints and the appropriate provisions for authorisation and inspection.

  2. Quantifying the biodegradation of phenanthrene by Pseudomonas stutzeri P16 in the presence of a nonionic surfactant.

    PubMed Central

    Grimberg, S J; Stringfellow, W T; Aitken, M D

    1996-01-01

    The low water solubility of polycyclic aromatic hydrocarbons is believed to limit their availability to microorganisms, which is a potential problem for bioremediation of polycyclic aromatic hydrocarbon-contaminated sites. Surfactants have been suggested to enhance the bioavailability of hydrophobic compounds, but both negative and positive effects of surfactants on biodegradation have been reported in the literature. Earlier, we presented mechanistic models of the effects of surfactants on phenanthrene dissolution and on the biodegradation kinetics of phenanthrene solubilized in surfactant micelles. In this study, we combined the biodegradation and dissolution models to quantify the influence of the surfactant Tergitol NP-10 on biodegradation of solid-phase phenanthrene by Pseudomonas stutzeri P16. Although micellized phenanthrene does not appear to be available directly to the bacterium, the ability of the surfactant to increase the phenanthrene dissolution rate resulted in an overall increase in bacterial growth rate in the presence of the surfactant. Experimental observations could be predicted well by the derived model with measured biokinetic and dissolution parameters. The proposed model therefore can serve as a base case for understanding the physical-chemical effects of surfactants on nonaqueous hydrocarbon bioavailability. PMID:8779577

  3. Modelling the relationship between zooplankton biomass and environmental variations in the distribution of 210Po during a one year cycle in northwestern Mediterranean coastal waters.

    PubMed

    Färber Lorda, Jaime; Tateda, Yutaka; Fowler, Scott W

    2017-08-01

    To clarify the relationship between zooplankton biomass and the environmental kinetics of the natural radionuclide 210 Po during a one-year period (October 1995 to November 1996) in northwestern Mediterranean coastal waters, a modelling analysis was applied. Using 210 Po concentrations in seawater and zooplankton, the 210 Po uptake rate constant from food for zooplankton was evaluated using a biokinetics calculation involving the uptake and the excretion rate constants between seawater and zooplankton. Using the transfer constants obtained, the 210 Po concentrations in zooplankton were reconstructed and validated by observed concentrations. The simulation results were in good agreement with the measured 210 Po concentrations in zooplankton. Assuming that 210 Po fecal excretion represents the majority of the excretion of 210 Po from zooplankton, the fecal matter associated 210 Po vertical flux was calculated, and compared with the observed vertical fluxes of 210 Po measured in sediment traps. The modelling evaluation showed that fecal pellet vertical transport could not fully explain the observed sinking fluxes of particulate organic matter at 150 m depth, suggesting that other sinking biodetrital aggregates are also important components of the plankton-derived vertical flux of 210 Po. The relationship between 210 Po concentration in seawater and that in rain and dry fallout and their potential effect on 210 Po concentrations in zooplankton at this location were also examined. A similar, but diphased trend between 210 Po in zooplankton and 210 Po in rain and dry fallout deposition rate was demonstrated. 210 Po concentrations in the dissolved phase of seawater tended to diminish as mean daily rainfall increased suggesting that rain inputs serve as a 210 Po dilution mechanism in seawater at this location. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. The reference individual of radiation protection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, K.F.; Cristy, M.

    1995-12-31

    The 70-kg {open_quotes}standard man{close_quotes} representing a typical Western adult male has been used in physiological models since at least the 1920s. In 1949 at the Chalk River conference, health physicists from the U.S., UK, and Canada agreed on the concept of a standard man to facilitate comparison of internal dose estimates. The 70-kg standard man included specifications of the masses of 25 organs and tissues, total body content of 15 elements, total water intake and output, water content of the body, and some anatomical and physiological data for the respiratory and gastrointestinal tracts. In 1959, in its Publication 2{sup 2}more » on permissible doses for internal radiation the International Commission on Radiological Protection (ICRP) modified standard man. In 1963 the ICRP established a task group to revise and extend the standard man concept. The name was changed later to Reference Man and the task group`s work was published in 1975 as ICRP Publication 23{sup 3}. Publication 23 similar to Publication 2, updates and documents the sources of the data. Data on women, children, and fetuses were also collected, where available, but these data were limited primarily to anatomical data and only a few reference values were established for these groups. Information assembled during the course of the effort on the Reference Man report was used at Oak Ridge National Laboratory (ORNL) to construct a mathematical representation of the body (a phantom) that was suitable for use with Monte Carlo methods in the calculation of organ doses. That effort was undertaken to improve estimates of dose from photon-emitting radionuclides residing within organs, so-called internal emitters. The phantom, although updated throughout the years, remains today as the basis for organ dose estimates in nuclear medicine and radiation protection and underlies the radiation risk data derived from the epidemiologic studies of the atomic bomb survivors of Hiroshima and Nagasaki.« less

  5. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    NASA Astrophysics Data System (ADS)

    Nogueira, P.; Zankl, M.; Schlattl, H.; Vaz, P.

    2011-11-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation—the germinative cells—absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  6. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    PubMed

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  7. Development and comparison of computational models for estimation of absorbed organ radiation dose in rainbow trout (Oncorhynchus mykiss) from uptake of iodine-131.

    PubMed

    Martinez, N E; Johnson, T E; Capello, K; Pinder, J E

    2014-12-01

    This study develops and compares different, increasingly detailed anatomical phantoms for rainbow trout (Oncorhynchus mykiss) for the purpose of estimating organ absorbed radiation dose and dose rates from (131)I uptake in multiple organs. The models considered are: a simplistic geometry considering a single organ, a more specific geometry employing additional organs with anatomically relevant size and location, and voxel reconstruction of internal anatomy obtained from CT imaging (referred to as CSUTROUT). Dose Conversion Factors (DCFs) for whole body as well as selected organs of O. mykiss were computed using Monte Carlo modeling, and combined with estimated activity concentrations, to approximate dose rates and ultimately determine cumulative radiation dose (μGy) to selected organs after several half-lives of (131)I. The different computational models provided similar results, especially for source organs (less than 30% difference between estimated doses), and whole body DCFs for each model (∼3 × 10(-3) μGy d(-1) per Bq kg(-1)) were comparable to DCFs listed in ICRP 108 for (131)I. The main benefit provided by the computational models developed here is the ability to accurately determine organ dose. A conservative mass-ratio approach may provide reasonable results for sufficiently large organs, but is only applicable to individual source organs. Although CSUTROUT is the more anatomically realistic phantom, it required much more resource dedication to develop and is less flexible than the stylized phantom for similar results. There may be instances where a detailed phantom such as CSUTROUT is appropriate, but generally the stylized phantom appears to be the best choice for an ideal balance between accuracy and resource requirements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Rotating and translating anthropomorphic head voxel models to establish an horizontal Frankfort plane for dental CBCT Monte Carlo simulations: a dose comparison study

    NASA Astrophysics Data System (ADS)

    Stratis, A.; Zhang, G.; Jacobs, R.; Bogaerts, R.; Bosmans, H.

    2016-12-01

    In order to carry out Monte Carlo (MC) dosimetry studies, voxel phantoms, modeling human anatomy, and organ-based segmentation of CT image data sets are applied to simulation frameworks. The resulting voxel phantoms preserve patient CT acquisition geometry; in the case of head voxel models built upon head CT images, the head support with which CT scanners are equipped introduces an inclination to the head, and hence to the head voxel model. In dental cone beam CT (CBCT) imaging, patients are always positioned in such a way that the Frankfort line is horizontal, implying that there is no head inclination. The orientation of the head is important, as it influences the distance of critical radiosensitive organs like the thyroid and the esophagus from the x-ray tube. This work aims to propose a procedure to adjust head voxel phantom orientation, and to investigate the impact of head inclination on organ doses in dental CBCT MC dosimetry studies. The female adult ICRP, and three in-house-built paediatric voxel phantoms were in this study. An EGSnrc MC framework was employed to simulate two commonly used protocols; a Morita Accuitomo 170 dental CBCT scanner (FOVs: 60  ×  60 mm2 and 80  ×  80 mm2, standard resolution), and a 3D Teeth protocol (FOV: 100  ×  90 mm2) in a Planmeca Promax 3D MAX scanner. Result analysis revealed large absorbed organ dose differences in radiosensitive organs between the original and the geometrically corrected voxel models of this study, ranging from  -45.6% to 39.3%. Therefore, accurate dental CBCT MC dose calculations require geometrical adjustments to be applied to head voxel models.

  9. Dental radiographic guidelines: a review.

    PubMed

    Kim, Irene H; Mupparapu, Muralidhar

    2009-05-01

    The 2004 American Dental Association (ADA)/US Food and Drug Administration (FDA) radiographic selection criteria and guidelines were reviewed and compared with the prior radiographic selection criteria and guidelines. The authors reviewed the publications from the US FDA, US Department of Health and Human Services, and National Council on Radiation Protection and Measurements. The positions outlined by the Canadian Dental Association and the European Commission were also reviewed and compared to US guidelines. The FDA guidelines were first published in 1987, and several changes have been made to them over the years. Recent literature reveals that the general compliance of these guidelines is very low, especially within dental schools in the United States and Canada. Little is known about the compliance outside of the dental school environment; however, it is expected to be low for various reasons. In 2007, the International Commission on Radiological Protection (ICRP) revised its estimates of tissue radiosensitivity, which resulted in effective doses of dental radiographs 32% to 422% higher than the 1990 ICRP guidelines. Flow charts summarizing the latest guidelines were developed to facilitate general compliance among practitioners. Based on the literature reviewed and the recent ICRP findings, it would be prudent for dental health care professionals to follow dental radiographic guidelines.

  10. New Stochastic Annual Limits on Intake for Selected Radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.

    Annual limits on intake (ALI) have historically been tabulated by the International Commission on Radiological Protection (e.g., ICRP 1979, 1961) and also by the Environmental Protection Agency (EPA 1988). These compilations have been rendered obsolete by more recent ICRP dosimetry methods, and, rather than provide new ALIs, the ICRP has opted instead to provide committed dose coefficients from which an ALI can be determined by a user for a specific set of conditions. The U.S. Department of Energy historically has referenced compilations of ALIs and has defined their method of calculation in its radiation protection regulation (10 CFDR 835), butmore » has never provided a specific compilation. Under June 2007 amendments to 10 CFR 835, ALIs can be calculated by dividing an appropriate dose limit, either 5-rem (0.05 Sv) effective dose or 50 rem (0.5 Sv) equivalent dose to an individual organ or tissue, by an appropriate committed dose coefficient. When based on effective dose, the ALI is often referred to as a stochastic annual limit on intake (SALI), and when based on the individual organ or tissue equivalent limit, it has often been called a deterministic annual limit on intake (DALI).« less

  11. All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry

    NASA Astrophysics Data System (ADS)

    Kramer, R.; Vieira, J. W.; Khoury, H. J.; Lima, F. R. A.; Fuelle, D.

    2003-05-01

    The MAX (Male Adult voXel) phantom has been developed from existing segmented images of a male adult body, in order to achieve a representation as close as possible to the anatomical properties of the reference adult male specified by the ICRP. The study describes the adjustments of the soft-tissue organ masses, a new dosimetric model for the skin, a new model for skeletal dosimetry and a computational exposure model based on coupling the MAX phantom with the EGS4 Monte Carlo code. Conversion coefficients between equivalent dose to the red bone marrow as well as effective MAX dose and air-kerma free in air for external photon irradiation from the front and from the back, respectively, are presented and compared with similar data from other human phantoms.

  12. Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcatili, S., E-mail: sara.marcatili@inserm.fr; Villoing, D.; Mauxion, T.

    Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclearmore » medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of

  13. Measurement of dose equivalent distribution on-board commercial jet aircraft.

    PubMed

    Kubančák, J; Ambrožová, I; Ploc, O; Pachnerová Brabcová, K; Štěpán, V; Uchihori, Y

    2014-12-01

    The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21: (1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36: , 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108: (2), 91-105 (2004)], the ambient dose equivalent rate Ḣ*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate Ḣ*(10) on-board selected types of aircraft. The authors found that Ḣ*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. The Biomechanisms of Metal and Metal-Oxide Nanoparticles’ Interactions with Cells

    PubMed Central

    Teske, Sondra S.; Detweiler, Corrella S.

    2015-01-01

    Humans are increasingly exposed to nanoparticles (NPs) in medicine and in industrial settings, where significant concentrations of NPs are common. However, NP interactions with and effects on biomolecules and organisms have only recently been addressed. Within we review the literature regarding proposed modes of action for metal and metal-oxide NPs, two of the most prevalent types manufactured. Iron-oxide NPs, for instance, are used as tracers for magnetic resonance imaging of oncological tumors and as vehicles for therapeutic drug delivery. Factors and theories that determine the physicochemical and biokinetic behaviors of NPs are discussed, along with the observed toxicological effects of NPs on cells. Key thermodynamic and kinetic models that explain the sources of energy transfer from NPs to biological targets are summarized, in addition to quantitative structural activity relationship (QSAR) modeling efforts. Future challenges for nanotoxicological research are discussed. We conclude that NP studies based on cell culture are often inconsistent and underestimate the toxicity of NPs. Thus, the effect of NPs needs to be examined in whole animal systems. PMID:25648173

  15. Second-order Kinetics of DTPA and Plutonium in Rat Plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Guthrie; Poudel, Deepesh; Klumpp, John Allan

    We report that in 2008, Serandour et al. reported on their in vitro experiment involving rat plasma samples obtained after an intravenous intake of plutonium citrate. Different amounts of DTPA were added to the plasma samples and the percentage of low-molecular-weight plutonium measured. Only when the DTPA dosage was three orders of magnitude greater than the recommended 30 μmol/kg was 100% of the plutonium apparently in the form of chelate. These data were modeled assuming three competing chemical reactions with other molecules that bind with plutonium. Here, time-dependent second-order kinetics of these reactions are calculated, intended eventually to become partmore » of a complete biokinetic model of DTPA action on actinides in laboratory animals or humans. The probability distribution of the ratio of stability constants for the reactants was calculated using Markov Chain Monte Carlo. In conclusion, these calculations substantiate that the inclusion of more reactions is needed in order to be in agreement with known stability constants.« less

  16. Second-order Kinetics of DTPA and Plutonium in Rat Plasma

    DOE PAGES

    Miller, Guthrie; Poudel, Deepesh; Klumpp, John Allan; ...

    2017-11-15

    We report that in 2008, Serandour et al. reported on their in vitro experiment involving rat plasma samples obtained after an intravenous intake of plutonium citrate. Different amounts of DTPA were added to the plasma samples and the percentage of low-molecular-weight plutonium measured. Only when the DTPA dosage was three orders of magnitude greater than the recommended 30 μmol/kg was 100% of the plutonium apparently in the form of chelate. These data were modeled assuming three competing chemical reactions with other molecules that bind with plutonium. Here, time-dependent second-order kinetics of these reactions are calculated, intended eventually to become partmore » of a complete biokinetic model of DTPA action on actinides in laboratory animals or humans. The probability distribution of the ratio of stability constants for the reactants was calculated using Markov Chain Monte Carlo. In conclusion, these calculations substantiate that the inclusion of more reactions is needed in order to be in agreement with known stability constants.« less

  17. Kinetics of nitrification in a fixed biofilm reactor using dewatered sludge-fly ash composite ceramic particle as a supporting medium.

    PubMed

    Lee, Mong-Chuan; Lin, Yen-Hui; Yu, Huang-Wei

    2014-11-01

    A mathematical model system was derived to describe the kinetics of ammonium nitrification in a fixed biofilm reactor using dewatered sludge-fly ash composite ceramic particle as a supporting medium. The model incorporates diffusive mass transport and Monod kinetics. The model was solved using a combination of the orthogonal collocation method and Gear's method. A batch test was conducted to observe the nitrification of ammonium-nitrogen ([Formula: see text]-N) and the growth of nitrifying biomass. The compositions of nitrifying bacterial community in the batch kinetic test were analyzed using PCR-DGGE method. The experimental results show that the most staining intensity abundance of bands occurred on day 2.75 with the highest biomass concentration of 46.5 mg/L. Chemostat kinetic tests were performed independently to evaluate the biokinetic parameters used in the model prediction. In the column test, the removal efficiency of [Formula: see text]-N was approximately 96 % while the concentration of suspended nitrifying biomass was approximately 16 mg VSS/L and model-predicted biofilm thickness reached up to 0.21 cm in the steady state. The profiles of denaturing gradient gel electrophoresis (DGGE) of different microbial communities demonstrated that indigenous nitrifying bacteria (Nitrospira and Nitrobacter) existed and were the dominant species in the fixed biofilm process.

  18. Reconstruction of Internal Doses for the Alpha-Risk Case-Control Study of Lung Cancer and Leukaemia Among European Nuclear Workers.

    PubMed

    Bingham, Derek; Bérard, Philippe; Birchall, Alan; Bull, Richard; Cardis, Elisabeth; Challeton-de Vathaire, Cécile; Grellier, James; Hurtgen, Christian; Puncher, Matthew; Riddell, Anthony; Thierry-Chef, Isabelle

    2017-05-01

    The Alpha-Risk study required the reconstruction of doses to lung and red bone marrow for lung cancer and leukaemia cases and their matched controls from cohorts of nuclear workers in the UK, France and Belgium. The dosimetrists and epidemiologists agreed requirements regarding the bioassay data, biokinetic and dosimetric models and dose assessment software to be used and doses to be reported. The best values to use for uncertainties on the monitoring data, setting of exposure regimes and characteristics of the exposure material, including lung solubility, were the responsibility of the dosimetrist responsible for each cohort. Among 1721 subjects, the median absorbed dose to the lung from alpha radiations was 2.1 mGy, with a maximum dose of 316 mGy. The lung doses calculated reflect the higher levels of exposure seen among workers in the early years of the nuclear industry compared to today. © Crown copyright 2016.

  19. Action levels for airborne uranium in the workplace: chemical and radiological assessments.

    PubMed

    Leggett, R W; Meck, R A

    2018-06-01

    A method is described for deriving two levels of action-an investigation level (IL) and an immediate action level (IAL)-for different forms and mixtures of the natural uranium (U) isotopes 234 U, 235 U, and 238 U in air in the workplace. An IL indicates the need to confirm the validity of moderately elevated measurements of airborne U and adequacy of confinement controls and determine whether work limitations are appropriate. An IAL indicates that safeguards should be put into place immediately, including removal of workers from further exposure until conditions are acceptable. Derivations of ILs and IALs are based on latest radiation protection guidance, information on chemical toxicity of U, and biokinetic models for U. An action level (IL or IAL) is the more restrictive of two derived values, the action level based on U as a chemical hazard and the action level based on U as a radiation hazard.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.R.

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- andmore » inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.« less

  1. SU-E-T-511: Inter-Rater Variability in Classification of Incidents in a New Incident Reporting System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pappas, D; Reis, S; Ali, A

    Purpose To determine how consistent the results of different raters are when reviewing the same cases within the Radiation Oncology Incident Learning System (ROILS). Methods Three second-year medical physics graduate students filled out incident reports in spreadsheets set up to mimic ROILS. All students studied the same 33 cases and independently entered their assessments, for a total of 99 reviewed cases. The narratives for these cases were obtained from a published International Commission on Radiological Protection (ICRP) report which included shorter narratives selected from the Radiation Oncology Safety Information System (ROSIS) database. Each category of questions was reviewed to seemore » how consistent the results were by utilizing free-marginal multirater kappa analysis. The percentage of cases where all raters shared full agreement or full disagreement was recorded to show which questions were answered consistently by multiple raters for a given case. The consistency among the raters was analyzed between ICRP and ROSIS cases to see if either group led to more reliable results. Results The categories where all raters agreed 100 percent in their choices were the event type (93.94 percent of cases 0.946 kappa) and the likelihood of the event being harmful to the patient (42.42 percent of cases 0.409 kappa). The categories where all raters disagreed 100 percent in their choices were the dosimetric severity scale (39.39 percent of cases 0.139 kappa) and the potential future toxicity (48.48 percent of cases 0.205 kappa). ROSIS had more cases where all raters disagreed than ICRP (23.06 percent of cases compared to 15.58 percent, respectively). Conclusion Despite reviewing the same cases, the results among the three raters was widespread. ROSIS narratives were shorter than ICRP, which suggests that longer narratives lead to more consistent results. This study shows that the incident reporting system can be optimized to yield more consistent results.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantone, M.C.

    The interest in biokinetic studies is driven by problems related to the physiopathology of oligoelements, chemical elemental pollution and radioactive release in case of nuclear accidents. The application of stable isotopes as tracers in studies of trace elements in the area of nutritional and food science is particularly attractive and specifically if considering the investigations on the most radiosensitive age groups of the population and the repeated studies on healthy people for the assessment of the bioavailability of different compounds. A tracer method based on stable isotope administration, which combines the simultaneous use of two tracers and proton activation analysismore » is presented. A study aimed to obtain molybdenum biokinetic data in humans was performed. One tracer ({sup 96}Mo) was orally administered and another ({sup 95}Mo) was intravenously injected to two fasting volunteer subjects. Venous blood samples were withdrawn at different postinjection times. The concentration in plasma for both the isotopes was determined by measuring the intensities of the gamma-lines from the technetium radioisotopes produced via (p,n) reactions. In the adopted experimental conditions a minimum detectable concentration of 2 ng isotope/ml plasma was attained. The parameters describing molybdenum kinetics were obtained for the two individuals. Moreover, the investigation was repeated with different tracer amounts for one of the two subjects, in both fasting and non-fasting condition.« less

  3. Dose conversion coefficients for photon exposure of the human eye lens

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  4. Pu-239 organ specific dosimetric model applied to non-human biota

    NASA Astrophysics Data System (ADS)

    Kaspar, Matthew Jason

    scientifically be valid for radionuclides emitting short-range radiation, as with Pu-239, where the energy is deposited locally. Two MCNPX models have been created and evaluated against ERICA Tool's aquatic model. One MCNPX model replicates ERICA Tool's intrinsic assumptions while the other uses a more realistic animal model adopted by ICRP Publication 108 and ERICA Tool for the organs "infinite" surrounding universe. In addition, the role of model geometry will be analyzed by focusing on four geometry sets for the same organ, including a spherical geometry. ERICA Tool will be compared to MCNPX results within and between each organ geometry set. In addition, the organ absorbed dose rate will be calculated for six rabbits located on the Maralinga nuclear test site as a preliminary test for further investigation. Data in all cases will be compared using percent differences and Student's t-test with respect to ERICA Tool's results and the overall average organ mean absorbed dose rate.

  5. Reanalysis of cancer mortality in Japanese A-bomb survivors exposed to low doses of radiation: bootstrap and simulation methods

    PubMed Central

    2009-01-01

    Background The International Commission on Radiological Protection (ICRP) recommended annual occupational dose limit is 20 mSv. Cancer mortality in Japanese A-bomb survivors exposed to less than 20 mSv external radiation in 1945 was analysed previously, using a latency model with non-linear dose response. Questions were raised regarding statistical inference with this model. Methods Cancers with over 100 deaths in the 0 - 20 mSv subcohort of the 1950-1990 Life Span Study are analysed with Poisson regression models incorporating latency, allowing linear and non-linear dose response. Bootstrap percentile and Bias-corrected accelerated (BCa) methods and simulation of the Likelihood Ratio Test lead to Confidence Intervals for Excess Relative Risk (ERR) and tests against the linear model. Results The linear model shows significant large, positive values of ERR for liver and urinary cancers at latencies from 37 - 43 years. Dose response below 20 mSv is strongly non-linear at the optimal latencies for the stomach (11.89 years), liver (36.9), lung (13.6), leukaemia (23.66), and pancreas (11.86) and across broad latency ranges. Confidence Intervals for ERR are comparable using Bootstrap and Likelihood Ratio Test methods and BCa 95% Confidence Intervals are strictly positive across latency ranges for all 5 cancers. Similar risk estimates for 10 mSv (lagged dose) are obtained from the 0 - 20 mSv and 5 - 500 mSv data for the stomach, liver, lung and leukaemia. Dose response for the latter 3 cancers is significantly non-linear in the 5 - 500 mSv range. Conclusion Liver and urinary cancer mortality risk is significantly raised using a latency model with linear dose response. A non-linear model is strongly superior for the stomach, liver, lung, pancreas and leukaemia. Bootstrap and Likelihood-based confidence intervals are broadly comparable and ERR is strictly positive by bootstrap methods for all 5 cancers. Except for the pancreas, similar estimates of latency and risk from 10

  6. United States Transuranium and Uranium Registries. Annual report February 1, 2000--January 31, 2001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ehrhart, Susan M.; Filipy, Ronald E.

    2001-07-01

    The United States Transuranium and Uranium Registries (USTUR) comprise a human tissue research program studying the deposition, biokinetics and dosimetry of the actinide elements in humans with the primary goals of providing data fundamental to the verification, refinement, or future development of radiation protection standards for these and other radionuclides, and of determining possible bioeffects on both a macro and subcellular level attributable to exposure to the actinides. This report covers USTUR activities during the year from February 2000 through January 2001.

  7. United States Transuranium and Uranium Registries. Annual report October 1, 1994 - September 30, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Harwick, L.A.; Markel, M.J.

    1996-07-01

    The United States Transuranium and Uranium Registries (USTUR) comprise a human tissue research program studying the deposition, biokinetics and dosimetry of the actinide elements in humans with the primary goals of providing data fundamental to the verification, refinement, or future development of radiation protection standards for these and other radionuclides, and of determining possible bioeffects on both a macro and subcellular level attributable to exposure to the actinides. This report covers USTUR activities during the year from October 1994 through September 1995.

  8. Estimating Children’s Soil/Dust Ingestion Rates through Retrospective Analyses of Blood Lead Biomonitoring from the Bunker Hill Superfund Site in Idaho

    PubMed Central

    von Lindern, Ian; Spalinger, Susan; Stifelman, Marc L.; Stanek, Lindsay Wichers; Bartrem, Casey

    2016-01-01

    Background: Soil/dust ingestion rates are important variables in assessing children’s health risks in contaminated environments. Current estimates are based largely on soil tracer methodology, which is limited by analytical uncertainty, small sample size, and short study duration. Objectives: The objective was to estimate site-specific soil/dust ingestion rates through reevaluation of the lead absorption dose–response relationship using new bioavailability data from the Bunker Hill Mining and Metallurgical Complex Superfund Site (BHSS) in Idaho, USA. Methods: The U.S. Environmental Protection Agency (EPA) in vitro bioavailability methodology was applied to archived BHSS soil and dust samples. Using age-specific biokinetic slope factors, we related bioavailable lead from these sources to children’s blood lead levels (BLLs) monitored during cleanup from 1988 through 2002. Quantitative regression analyses and exposure assessment guidance were used to develop candidate soil/dust source partition scenarios estimating lead intake, allowing estimation of age-specific soil/dust ingestion rates. These ingestion rate and bioavailability estimates were simultaneously applied to the U.S. EPA Integrated Exposure Uptake Biokinetic Model for Lead in Children to determine those combinations best approximating observed BLLs. Results: Absolute soil and house dust bioavailability averaged 33% (SD ± 4%) and 28% (SD ± 6%), respectively. Estimated BHSS age-specific soil/dust ingestion rates are 86–94 mg/day for 6-month- to 2-year-old children and 51–67 mg/day for 2- to 9-year-old children. Conclusions: Soil/dust ingestion rate estimates for 1- to 9-year-old children at the BHSS are lower than those commonly used in human health risk assessment. A substantial component of children’s exposure comes from sources beyond the immediate home environment. Citation: von Lindern I, Spalinger S, Stifelman ML, Stanek LW, Bartrem C. 2016. Estimating children’s soil/dust ingestion

  9. Estimating Children's Soil/Dust Ingestion Rates through Retrospective Analyses of Blood Lead Biomonitoring from the Bunker Hill Superfund Site in Idaho.

    PubMed

    von Lindern, Ian; Spalinger, Susan; Stifelman, Marc L; Stanek, Lindsay Wichers; Bartrem, Casey

    2016-09-01

    Soil/dust ingestion rates are important variables in assessing children's health risks in contaminated environments. Current estimates are based largely on soil tracer methodology, which is limited by analytical uncertainty, small sample size, and short study duration. The objective was to estimate site-specific soil/dust ingestion rates through reevaluation of the lead absorption dose-response relationship using new bioavailability data from the Bunker Hill Mining and Metallurgical Complex Superfund Site (BHSS) in Idaho, USA. The U.S. Environmental Protection Agency (EPA) in vitro bioavailability methodology was applied to archived BHSS soil and dust samples. Using age-specific biokinetic slope factors, we related bioavailable lead from these sources to children's blood lead levels (BLLs) monitored during cleanup from 1988 through 2002. Quantitative regression analyses and exposure assessment guidance were used to develop candidate soil/dust source partition scenarios estimating lead intake, allowing estimation of age-specific soil/dust ingestion rates. These ingestion rate and bioavailability estimates were simultaneously applied to the U.S. EPA Integrated Exposure Uptake Biokinetic Model for Lead in Children to determine those combinations best approximating observed BLLs. Absolute soil and house dust bioavailability averaged 33% (SD ± 4%) and 28% (SD ± 6%), respectively. Estimated BHSS age-specific soil/dust ingestion rates are 86-94 mg/day for 6-month- to 2-year-old children and 51-67 mg/day for 2- to 9-year-old children. Soil/dust ingestion rate estimates for 1- to 9-year-old children at the BHSS are lower than those commonly used in human health risk assessment. A substantial component of children's exposure comes from sources beyond the immediate home environment. von Lindern I, Spalinger S, Stifelman ML, Stanek LW, Bartrem C. 2016. Estimating children's soil/dust ingestion rates through retrospective analyses of blood lead biomonitoring from the Bunker

  10. Comparative biokinetics of trivalent radionuclides with similar ionic dimensions: promethium-147, curium-242 and americium-241.

    PubMed

    Priest, N D

    2007-09-01

    Data on the distribution and redistribution patterns in the laboratory rat of three trivalent elements with a similar ionic radius have been compared. This showed that these distributions for the two ions with the same ionic radius (111 pm), i.e., those of promethium (a lanthanoid) and curium (an actinoid), were indistinguishable and that americium, with a slightly larger ion size (111.5 pm), behaved similarly. The results are consistent with the suggestion that ion size is the only important factor controlling the deposition and redistribution patterns of trivalent lanthanoids and actinoids in rats. The result is important because it suggests that the same radiological protection dosimetry models should be used for trivalent actinoids and lanthanoids, that human volunteer data generated for lanthanoid isotopes can be used to predict the behavior of actinoids with the same ion size, and that appropriate pairs of beta-particle-emitting lanthanoid and alpha-particle-emitting actinoids could be used to study the relative toxicity of alpha and beta particles in experimental animals.

  11. Effect of blood activity on dosimetric calculations for radiopharmaceuticals

    NASA Astrophysics Data System (ADS)

    Zvereva, Alexandra; Petoussi-Henss, Nina; Li, Wei Bo; Schlattl, Helmut; Oeh, Uwe; Zankl, Maria; Graner, Frank Philipp; Hoeschen, Christoph; Nekolla, Stephan G.; Parodi, Katia; Schwaiger, Markus

    2016-11-01

    The objective of this work was to investigate the influence of the definition of blood as a distinct source on organ doses, associated with the administration of a novel radiopharmaceutical for positron emission tomography-computed tomography (PET/CT) imaging—(S)-4-(3-18F-fluoropropyl)-L-glutamic acid (18F-FSPG). Personalised pharmacokinetic models were constructed based on clinical PET/CT images from five healthy volunteers and blood samples from four of them. Following an identifiability analysis of the developed compartmental models, person-specific model parameters were estimated using the commercial program SAAM II. Organ doses were calculated in accordance to the formalism promulgated by the Committee on Medical Internal Radiation Dose (MIRD) and the International Commission on Radiological Protection (ICRP) using specific absorbed fractions for photons and electrons previously derived for the ICRP reference adult computational voxel phantoms. Organ doses for two concepts were compared: source organ activities in organs parenchyma with blood as a separate source (concept-1); aggregate activities in perfused source organs without blood as a distinct source (concept-2). Aggregate activities comprise the activities of organs parenchyma and the activity in the regional blood volumes (RBV). Concept-1 resulted in notably higher absorbed doses for most organs, especially non-source organs with substantial blood contents, e.g. lungs (92% maximum difference). Consequently, effective doses increased in concept-1 compared to concept-2 by 3-10%. Not considering the blood as a distinct source region leads to an underestimation of the organ absorbed doses and effective doses. The pronounced influence of the blood even for a radiopharmaceutical with a rapid clearance from the blood, such as 18F-FSPG, suggests that blood should be introduced as a separate compartment in most compartmental pharmacokinetic models and blood should be considered as a distinct source in

  12. ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures.

    PubMed

    López, P Ortiz; Dauer, L T; Loose, R; Martin, C J; Miller, D L; Vañó, E; Doruff, M; Padovani, R; Massera, G; Yoder, C

    2018-03-01

    In recent publications, such as Publications 117 and 120, the Commission provided practical advice for physicians and other healthcare personnel on measures to protect their patients and themselves during interventional procedures. These measures can only be effective if they are encompassed by a framework of radiological protection elements, and by the availability of professionals with responsibilities in radiological protection. This framework includes a radiological protection programme with a strategy for exposure monitoring, protective garments, education and training, and quality assurance of the programme implementation. Professionals with responsibilities in occupational radiological protection for interventional procedures include: medical physicists; radiological protection specialists; personnel working in dosimetry services; clinical applications support personnel from the suppliers and maintenance companies; staff engaged in training, standardisation of equipment, and procedures; staff responsible for occupational health; hospital administrators responsible for providing financial support; and professional bodies and regulators. This publication addresses these elements and these audiences, and provides advice on specific issues, such as assessment of effective dose from dosimeter readings when an apron is worn, estimation of exposure of the lens of the eye (with and without protective eyewear), extremity monitoring, selection and testing of protective garments, and auditing the interventional procedures when occupational doses are unusually high or low (the latter meaning that the dosimeter may not have been worn).

  13. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    PubMed Central

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Toncheva, Greta; Yoshizumi, Terry T.; Frush, Donald P.

    2011-01-01

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient’s clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDIvol) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients

  14. An image-based skeletal model for the ICRP reference adult male—specific absorbed fractions for neutron-generated recoil protons

    NASA Astrophysics Data System (ADS)

    Jokisch, D. W.; Rajon, D. A.; Bahadori, A. A.; Bolch, W. E.

    2011-11-01

    Recoiling hydrogen nuclei are a principle mechanism for energy deposition from incident neutrons. For neutrons incident on the human skeleton, the small sizes of two contrasting media (trabecular bone and marrow) present unique problems due to a lack of charged-particle (protons) equilibrium. Specific absorbed fractions have been computed for protons originating in the human skeletal tissues for use in computing neutron dose response functions. The proton specific absorbed fractions were computed using a pathlength-based range-energy calculation in trabecular skeletal samples of a 40 year old male cadaver.

  15. Response Funtions for Computing Absorbed Dose to Skeletal Tissues from Photon Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckerman, Keith F; Bolch, W E; Zankl, M

    2007-01-01

    The calculation of absorbed dose in skeletal tissues at radiogenic risk has been a difficult problem because the relevant structures cannot be represented in conventional geometric terms nor can they be visualised in the tomographic image data used to define the computational models of the human body. The active marrow, the tissue of concern in leukaemia induction, is present within the spongiosa regions of trabecular bone, whereas the osteoprogenitor cells at risk for bone cancer induction are considered to be within the soft tissues adjacent to the mineral surfaces. The International Commission on Radiological Protection (ICRP) recommends averaging the absorbedmore » energy over the active marrow within the spongiosa and over the soft tissues within 10 mm of the mineral surface for leukaemia and bone cancer induction, respectively. In its forthcoming recommendation, it is expected that the latter guidance will be changed to include soft tissues within 50 mm of the mineral surfaces. To address the computational problems, the skeleton of the proposed ICRP reference computational phantom has been subdivided to identify those voxels associated with cortical shell, spongiosa and the medullary cavity of the long bones. It is further proposed that the Monte Carlo calculations with these phantoms compute the energy deposition in the skeletal target tissues as the product of the particle fluence in the skeletal subdivisions and applicable fluence-to-dose response functions. This paper outlines the development of such response functions for photons.« less

  16. Implementation of the integrated approach in different types of exposure scenarios.

    PubMed

    Copplestone, D; Hirth, G; Johansen, M; Lazo, E; Takala, J; Sakai, K; Yankovich, T

    2018-01-01

    The International Commission on Radiological Protection (ICRP) recognises three types of exposure situations: planned, existing, and emergency. In all three situations, the release of radionuclides into the natural environment leads to exposures of non-human biota, as well as the potential for exposures of the public. This paper describes how the key principles of the ICRP system of radiological protection apply to non-human biota and members of the public in each of these exposure situations. Current work in this area within ICRP Task Group 105 is highlighted. For example, how simplified numeric criteria may be used in planned exposure situations that are protective of both the public and non-human biota. In emergency exposure situations, the initial response will always be focused on human protection; however, understanding the potential impacts of radionuclide releases on non-human biota will likely become important in terms of communication as governments and the public seek to understand the exposures that are occurring. For existing exposure situations, there is a need to better understand the potential impacts of radionuclides on animals and plants, especially when deciding on protective actions. Understanding the comparative impacts from radiological, non-radiological, and physical aspects is often important in managing the remediation of legacy sites. Task Group 105 is making use of case studies of how exposure situations have been managed in the past to provide additional guidance and advice for the protection of non-human biota.

  17. Analysis of linear energy transfers and quality factors of charged particles produced by spontaneous fission neutrons from 252Cf and 244Pu in the human body.

    PubMed

    Endo, Akira; Sato, Tatsuhiko

    2013-04-01

    Absorbed doses, linear energy transfers (LETs) and quality factors of secondary charged particles in organs and tissues, generated via the interactions of the spontaneous fission neutrons from (252)Cf and (244)Pu within the human body, were studied using the Particle and Heavy Ion Transport Code System (PHITS) coupled with the ICRP Reference Phantom. Both the absorbed doses and the quality factors in target organs generally decrease with increasing distance from the source organ. The analysis of LET distributions of secondary charged particles led to the identification of the relationship between LET spectra and target-source organ locations. A comparison between human body-averaged mean quality factors and fluence-averaged radiation weighting factors showed that the current numerical conventions for the radiation weighting factors of neutrons, updated in ICRP103, and the quality factors for internal exposure are valid.

  18. Analysis of the criteria used by the International Commission on Radiological Protection to justify the setting of numerical protection level values.

    PubMed

    2006-01-01

    This report compiles the various numerical protection level values published by the International Commission on Radiological Protection (ICRP) since its 1990 Recommendations (Publication 60). Several terms are used to denominate the protection levels: individual dose limit, 'maximum' individual dose, dose constraint, exemption level, exclusion level, action level, or intervention level. The reasons provided by the Commission for selecting the associated numerical values is quoted as far as available. In some cases the rationale is not totally explicit in the original ICRP report concerned; in such cases the Task Group that prepared the present report have proposed their own interpretation. Originally, this report was prepared by a Task Group at CEPN, a French research and development center, in behalf of IRSN, a French public expert body engaged in radiological protection and nuclear safety. It is published here with kind permission by CEPN and IRSN.

  19. Bioadsorber efficiency, design, and performance forecasting for alachlor removal.

    PubMed

    Badriyha, Badri N; Ravindran, Varadarajan; Den, Walter; Pirbazari, Massoud

    2003-10-01

    This study discusses a mathematical modeling and design protocol for bioactive granular activated carbon (GAC) adsorbers employed for purification of drinking water contaminated by chlorinated pesticides, exemplified by alachlor. A thin biofilm model is discussed that incorporates the following phenomenological aspects: film transfer from the bulk fluid to the adsorbent particles, diffusion through the biofilm immobilized on adsorbent surface, adsorption of the contaminant into the adsorbent particle. The modeling approach involved independent laboratory-scale experiments to determine the model input parameters. These experiments included adsorption isotherm studies, adsorption rate studies, and biokinetic studies. Bioactive expanded-bed adsorber experiments were conducted to obtain realistic experimental data for determining the ability of the model for predicting adsorber dynamics under different operating conditions. The model equations were solved using a computationally efficient hybrid numerical technique combining orthogonal collocation and finite difference methods. The model provided accurate predictions of adsorber dynamics for bioactive and non-bioactive scenarios. Sensitivity analyses demonstrated the significance of various model parameters, and focussed on enhancement in certain key parameters to improve the overall process efficiency. Scale-up simulation studies for bioactive and non-bioactive adsorbers provided comparisons between their performances, and illustrated the advantages of bioregeneration for enhancing their effective service life spans. Isolation of microbial species revealed that fungal strains were more efficient than bacterial strains in metabolizing alachlor. Microbial degradation pathways for alachlor were proposed and confirmed by the detection of biotransformation metabolites and byproducts using gas chromatography/mass spectrometry.

  20. Uranium bone content as an indicator of chronic environmental exposure from drinking water.

    PubMed

    Larivière, Dominic; Tolmachev, Sergei Y; Kochermin, Vera; Johnson, Sonia

    2013-07-01

    Uranium (U) is an ubiquitous radioelement found in drinking water and food. As a consequence of its prevalence, most humans ingest a few micrograms (μg) of this element daily. It is incorporated in various organs and tissues. Several studies have demonstrated that ingested U is deposited mainly in bones. Therefore, U skeletal content could be considered as a prime indicator for low-level chronic intake. In this study, 71 archived vertebrae bone samples collected in seven Canadian cities were subjected to digestion and U analysis by inductively coupled plasma mass spectrometry. These results were correlated with U concentrations in municipal drinking water supplies, with the data originating from historical studies performed by Health Canada. A strong relationship (r(2) = 0.97) was observed between the averaged U total skeletal content and averaged drinking water concentration, supporting the hypothesis that bones are indeed a good indicator of U intake. Using a PowerBASIC compiler to process an ICRP systemic model for U (ICRP, 1995a), U total skeletal content was estimated using two gastrointestinal tract absorption factors (ƒ1 = 0.009 and 0.03). Comparisons between observed and modelled skeletal contents as a function of U intake from drinking water tend to demonstrate that neither of the ƒ1 values can adequately estimate observed values. An ƒ1value of 0.009 provides a realistic estimate for intake resulting from food consumption only (6.72 μg) compared to experimental data (7.4 ± 0.8 μg), whereas an ƒ1value of 0.03 tends to better estimate U skeletal content at higher levels of U (1-10 μg L(-1)) in drinking water. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Comparison of internal dosimetry factors for three classes of adult computational phantoms with emphasis on I-131 in the thyroid

    NASA Astrophysics Data System (ADS)

    Lamart, Stephanie; Bouville, Andre; Simon, Steven L.; Eckerman, Keith F.; Melo, Dunstana; Lee, Choonsik

    2011-11-01

    The S values for 11 major target organs for I-131 in the thyroid were compared for three classes of adult computational human phantoms: stylized, voxel and hybrid phantoms. In addition, we compared specific absorbed fractions (SAFs) with the thyroid as a source region over a broader photon energy range than the x- and gamma-rays of I-131. The S and SAF values were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms and the University of Florida (UF) hybrid phantoms by using the Monte Carlo transport method, while the S and SAF values for the Oak Ridge National Laboratory (ORNL) stylized phantoms were obtained from earlier publications. Phantoms in our calculations were for adults of both genders. The 11 target organs and tissues that were selected for the comparison of S values are brain, breast, stomach wall, small intestine wall, colon wall, heart wall, pancreas, salivary glands, thyroid, lungs and active marrow for I-131 and thyroid as a source region. The comparisons showed, in general, an underestimation of S values reported for the stylized phantoms compared to the values based on the ICRP voxel and UF hybrid phantoms and relatively good agreement between the S values obtained for the ICRP and UF phantoms. Substantial differences were observed for some organs between the three types of phantoms. For example, the small intestine wall of ICRP male phantom and heart wall of ICRP female phantom showed up to eightfold and fourfold greater S values, respectively, compared to the reported values for the ORNL phantoms. UF male and female phantoms also showed significant differences compared to the ORNL phantom, 4.0-fold greater for the small intestine wall and 3.3-fold greater for the heart wall. In our method, we directly calculated the S values without using the SAFs as commonly done. Hence, we sought to confirm the differences observed in our S values by comparing the SAFs among the phantoms with the thyroid as a

  2. Assessing the stability of soil organic matter by fractionation and 13C isotope techniques

    NASA Astrophysics Data System (ADS)

    Larionova, A. A.; Zolotareva, B. N.; Kvitkina, A. K.; Evdokimov, I. V.; Bykhovets, S. S.; Stulin, A. F.; Kuzyakov, Ya. V.; Kudeyarov, V. N.

    2015-02-01

    Carbon pools of different stabilities have been separated from the soil organic matter of agrochernozem and agrogray soil samples. The work has been based on the studies of the natural abundance of the carbon isotope composition by C3-C4 transition using the biokinetic, size-density, and chemical fractionation (6 M HCl hydrolysis) methods. The most stable pools with the minimum content of new carbon have been identified by particle-size and chemical fractionation. The content of carbon in the fine fractions has been found to be close to that in the nonhydrolyzable residue. This pool makes up 65 and 48% of Corg in the agrochernozems and agrogray soils, respectively. The combination of the biokinetic approach with particle-size fractionation or 6 M HCl hydrolysis has allowed assessing the size of the medium-stable organic carbon pool with a turnover time of several years to several decades. The organic matter pool with this turnover rate is usually identified from the variation in the 13C abundance by C3-C4 transition. In the agrochernozems and agrogray soils, the medium-stable carbon pool makes up 35 and 46% of Corg, respectively. The isotope indication may be replaced by a nonisotope method to significantly expand the study of the inert and mediumstable organic matter pools in the geographical aspect, but this requires a comparative analysis of particle-size and chemical fractionation data for all Russian soils.

  3. An exposure and health risk assessment of lead (Pb) in lipstick.

    PubMed

    Monnot, Andrew D; Christian, Whitney V; Abramson, Matthew M; Follansbee, Mark H

    2015-06-01

    Lead (Pb) content in lipstick and other consumer products has become an increasing concern. In 2010, the United States Food and Drug Administration tested 400 lipstick samples and found a maximum Pb concentration of 7.19 ppm. To assess the safety of lipstick in adults that chronically apply lipstick as well as instances where children might incidentally ingest lipstick products, the United States Environmental Protection Agency's (US EPA) Adult Lead Model and Integrated Exposure Uptake Biokinetic Model for Lead in Children were used to determine the blood Pb concentrations of adults and children ingesting varying amounts of lipstick of different Pb concentrations. Modeled blood Pb concentrations were compared with oral ingestion guidelines and to the Centers for Disease Control and the US EPA's actionable blood Pb levels of 5 and 10 µg/dL. Background Pb exposure was the primary contributor to estimated blood Pb levels (BLLs) in children and adults, and Pb exposure from lipstick did not significantly increase estimated BLLs. These results suggest that the safety of consumer products and cosmetics should be assessed not only by the presence and amounts of hazardous contents, but also in conjunction with an assessment of estimated background exposures and comparison to health-based standards. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Substrate inhibition kinetics of phenol biodegradation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goudar, C.T.; Ganji, S.H.; Pujar, B.G.

    Phenol biodegradation was studied in batch experiments using an acclimated inoculum and initial phenol concentrations ranging from 0.1 to 1.3 g/L. Phenol depletion an associated microbial growth were monitored over time to provide information that was used to estimate the kinetics of phenol biodegradation. Phenol inhibited biodegradation at high concentrations, and a generalized substrate inhibition model based on statistical thermodynamics was used to describe the dynamics of microbial growth in phenol. For experimental data obtained in this study, the generalized substrate inhibition model reduced to a form that is analogous to the Andrews equation, and the biokinetic parameters {micro}{sub max},more » maximum specific growth; K{sub s}, saturation constant; and K{sub i}, inhibition constant were estimated as 0.251 h{sup {minus}1}, 0.011 g/L, and 0.348 g/L, respectively, using a nonlinear least squares technique. Given the wide variability in substrate inhibition models used to describe phenol biodegradation, an attempt was made to justify selection of particular model based on theoretical considerations. Phenol biodegradation data from nine previously published studies were used in the generalized substrate inhibition model to determine the appropriate form of the substrate inhibition model. In all nine cases, the generalized substrate inhibition model reduced to a form analogous to the Andrews equation suggesting the suitability of the Andrews equation to describe phenol biodegradation data.« less

  5. THE SCIENCE BEHIND THE ICRP 2005 RECOMMENDATIONS

    EPA Science Inventory

    The ICRP 2005 Recommendations are stated to be "based on a simple, but widely applicable, general system of protection that will clarify its objectives and will provide a basis for the more formal systems needed by operating managements and regulators". The Recommendati...

  6. Accumulation and distributions of {sup 137}Cs in fresh water snail Pila ampullacea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suseno, Heny, E-mail: henis@batan.go.id

    2014-10-24

    Pila ampullacea are found in tropical freshwaters of Indonesia. This snail exhibit several characteristics of ideal indicator organisms in order to understand the bioaccumulation of {sup 137}Cs. Biokinetic experiment was performaced in aquaria system and under influenced of concentration K{sup +} in water. The result of experiment shown that Under difference K{sup +} concentration in water, Pila ampullacea have capability to accumulated {sup 137}Cs with CF value range 8.95 to 12.52 ml.g{sup −1}. Both uptake and depuration rate were influenced by concentration of K{sup +} in water.

  7. Lung dosimetry for inhaled long-lived radionuclides and radon progeny.

    PubMed

    Hussain, M; Winkler-Heil, R; Hofmann, W

    2011-05-01

    The current version of the stochastic lung dosimetry model IDEAL-DOSE considers deposition in the whole tracheobronchial (TB) and alveolar airway system, while clearance is restricted to TB airways. For the investigation of doses produced by inhaled long-lived radionuclides (LLR) together with short-lived radon progeny, alveolar clearance has to be considered. Thus, present dose calculations are based on the average transport rates proposed for the revision of the ICRP human respiratory tract model. The results obtained indicate that LLR cleared from the alveolar region can deliver up to two to six times higher doses to the TB region when compared with the doses from directly deposited particles. Comparison of LLR doses with those of short-lived radon progeny indicates that LLR in uranium mines can deliver up to 5 % of the doses predicted for the short-lived radon daughters.

  8. Development of 3D Advanced Rapid Prototyping Multipurpose Structures with Micro and Nano Materials

    DTIC Science & Technology

    2006-05-01

    dynamic parts, cinematic behavior, geometric evaluation, quality and reliability). The RP elements produced normally are moulds (for metal casting but...rapid tooling from Stereo Lithography”, Proceedings of the Seventh International ICRP Conference, California, USA, 9–12 March 1997, pp. 338–354 [5] P

  9. Silica coating influences the corona and biokinetics of cerium oxide nanoparticles.

    PubMed

    Konduru, Nagarjun V; Jimenez, Renato J; Swami, Archana; Friend, Sherri; Castranova, Vincent; Demokritou, Philip; Brain, Joseph D; Molina, Ramon M

    2015-10-12

    The physicochemical properties of nanoparticles (NPs) influence their biological outcomes. We assessed the effects of an amorphous silica coating on the pharmacokinetics and pulmonary effects of CeO2 NPs following intratracheal (IT) instillation, gavage and intravenous injection in rats. Uncoated and silica-coated CeO2 NPs were generated by flame spray pyrolysis and later neutron-activated. These radioactive NPs were IT-instilled, gavaged, or intravenously (IV) injected in rats. Animals were analyzed over 28 days post-IT, 7 days post-gavage and 2 days post-injection. Our data indicate that silica coating caused more but transient lung inflammation compared to uncoated CeO2. The transient inflammation of silica-coated CeO2 was accompanied by its enhanced clearance. Then, from 7 to 28 days, clearance was similar although significantly more (141)Ce from silica-coated (35%) was cleared than from uncoated (19%) (141)CeO2 in 28 days. The protein coronas of the two NPs were significantly different when they were incubated with alveolar lining fluid. Despite more rapid clearance from the lungs, the extrapulmonary (141)Ce from silica-coated (141)CeO2 was still minimal (<1%) although lower than from uncoated (141)CeO2 NPs. Post-gavage, nearly 100% of both NPs were excreted in the feces consistent with very low gut absorption. Both IV-injected (141)CeO2 NP types were primarily retained in the liver and spleen. The silica coating significantly altered the plasma protein corona composition and enhanced retention of (141)Ce in other organs except the liver. We conclude that silica coating of nanoceria alters the biodistribution of cerium likely due to modifications in protein corona formation after IT and IV administration.

  10. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xiang; Samei, Ehsan; Segars, W. Paul

    2011-01-15

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GEmore » Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller

  11. The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segars, W. P., E-mail: paul.segars@duke.edu; Norris, Hannah; Sturgeon, Gregory M.

    Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicingmore » experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even

  12. Occupational dose constraints for the lens of the eye for interventional radiologists and interventional cardiologists in the UK.

    PubMed

    Mairs, William DA

    2016-06-01

    The International Commission on Radiological Protection (ICRP) has recommended a 20 mSv year(-1) dose limit for the lens of the eye, which has been adopted in the European Union Basic Safety Standards. Interventional radiologists (IRs) and interventional cardiologists (ICs) are likely to be affected by this. The effects of radiation in the lens are somewhat uncertain, and the ICRP explicitly recommend optimization. Occupational dose constraints are part of the optimization process and define a level of dose which ought to be achievable in a well-managed practice. This commentary calls on the professional bodies to review a need for national constraints to guide local decisions. Consideration is given to developing such constraints using maximum expected doses in high-workload facilities with good radiation protection practices and application of a factor allowing for attenuation by lead glasses (LG). Doses are based on a Public Health England survey of eye dose in the UK. Maximum expected doses for ICs are approximately 21 mSv year(-1), neglecting LG. However, the extent of IR exposure is not yet fully known, and further evidence is required before conclusions are drawn. A Health and Safety Laboratory review of LG established a conservative dose reduction factor of 3 for models available in 2012. Application of this factor provides a dose constraint of 7 mSv year(-1) to the eye for ICs. To achieve this constraint, those employers with the most exposed ICs will have to provide and ensure the correct use of a ceiling-suspended eye shield and LG.

  13. Radiological risk assessment of Capstone depleted uranium aerosols.

    PubMed

    Hahn, Fletcher F; Roszell, Laurie E; Daxon, Eric G; Guilmette, Raymond A; Parkhurst, Mary Ann

    2009-03-01

    Assessment of the health risk from exposure to aerosols of depleted uranium (DU) is an important outcome of the Capstone aerosol studies that established exposure ranges to personnel in armored combat vehicles perforated by DU munitions. Although the radiation exposure from DU is low, there is concern that DU deposited in the body may increase cancer rates. Radiation doses to various organs of the body resulting from the inhalation of DU aerosols measured in the Capstone studies were calculated using International Commission on Radiological Protection (ICRP) models. Organs and tissues with the highest calculated committed equivalent 50-y doses were lung and extrathoracic tissues (nose and nasal passages, pharynx, larynx, mouth, and thoracic lymph nodes). Doses to the bone surface and kidney were about 5 to 10% of the doses to the extrathoracic tissues. Organ-specific risks were estimated using ICRP and U.S. Environmental Protection Agency (EPA) methodologies. Risks for crewmembers and first responders were determined for selected scenarios based on the time interval of exposure and for vehicle and armor type. The lung was the organ with the highest cancer mortality risk, accounting for about 97% of the risks summed from all organs. The highest mean lifetime risk for lung cancer for the scenario with the longest exposure time interval (2 h) was 0.42%. This risk is low compared with the natural or background risk of 7.35%. These risks can be significantly reduced by using an existing ventilation system (if operable) and by reducing personnel time in the vehicle immediately after perforation.

  14. MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry-Standardization of Nomenclature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolch, W E; Eckerman, Keith F; Sgouros, George

    2009-03-01

    The internal dosimetry schema of the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine has provided a broad framework for assessment of the absorbed dose to whole organs, tissue subregions, voxelized tissue structures, and individual cellular compartments for use in both diagnostic and therapeutic nuclear medicine. The schema was originally published in 1968, revised in 1976, and republished in didactic form with comprehensive examples as the MIRD primer in 1988 and 1991. The International Commission on Radiological Protection (ICRP) is an organization that also supplies dosimetric models and technical data, for use in providing recommendations formore » limits on ionizing radiation exposure to workers and members of the general public. The ICRP has developed a dosimetry schema similar to that of the MIRD Committee but has used different terminology and symbols for fundamental quantities such as the absorbed fraction, specific absorbed fraction, and various dose coefficients. The MIRD Committee objectives for this pamphlet are 3-fold: to restate its schema for assessment of absorbed dose in a manner consistent with the needs of both the nuclear medicine and the radiation protection communities, with the goal of standardizing nomenclature; to formally adopt the dosimetry quantities equivalent dose and effective dose for use in comparative evaluations of potential risks of radiation-induced stochastic effects to patients after nuclear medicine procedures; and to discuss the need to identify dosimetry quantities based on absorbed dose that address deterministic effects relevant to targeted radionuclide therapy.« less

  15. Assessing the International Landscape

    Cancer.gov

    On April 11th, 2018 the NCI Center for Research Strategy, in coordination with CGH, hosted the Annual Meeting of the International Cancer Research Partnership (ICRP). The meeting marked 18 years of a successful partnership, representing 124 organizations that fund cancer research projects in 145 countries.

  16. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE PAGES

    Hiller, Mauritius; Dewji, Shaheen Azim

    2017-02-16

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  17. The optimisation of occupational potential exposures - preliminary considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crouail, P.; Guimaraes, L.

    1995-03-01

    One of the major innovation brought about the ICRP 60 recommendations and emphasized by the ICRP 64 publication, is the introduction of the concept of potential exposures into the system of radiological protection. Potential exposures are characterized by {open_quotes}probability of occurrence lesser than unity{close_quotes} and {open_quotes}radiological risks exceeding normal levels{close_quotes} where normal must be interpreted as not exceeding the planned routine exposures. It is then necessary to develop consensual methods to look for and choose the optimum scenarios (i.e. those for which probability of events and possible consequences have been reduced as low as reasonably achievable). Moreover, the boundaries formore » the unacceptable levels of risks for workers should be defined, as well as reasonable risk indicators. The aim of this paper is to discuss the actual changes in the field of occupational radiological protection, induced by the potential exposure concept with particular emphasize on the optimization of protection.« less

  18. Focal role of tolerability and reasonableness in the radiological protection system.

    PubMed

    Schneider, T; Lochard, J; Vaillant, L

    2016-06-01

    The concepts of tolerability and reasonableness are at the core of the International Commission on Radiological Protection (ICRP) system of radiological protection. Tolerability allows the definition of boundaries for implementing ICRP principles, while reasonableness contributes to decisions regarding adequate levels of protection, taking into account the prevailing circumstances. In the 1970s and 1980s, attempts to find theoretical foundations in risk comparisons for tolerability and cost-benefit analysis for reasonableness failed. In practice, the search for a rational basis for these concepts will never end. Making a wise decision will always remain a matter of judgement and will depend on the circumstances as well as the current knowledge and past experience. This paper discusses the constituents of tolerability and reasonableness at the heart of the radiological protection system. It also emphasises the increasing role of stakeholder engagement in the quest for tolerability and reasonableness since Publication 103. © The International Society for Prosthetics and Orthotics.

  19. Human absorption and retention of polonium-210 from caribou meat.

    PubMed

    Thomas, P A; Fisenne, I; Chorney, D; Baweja, A S; Tracy, B L

    2001-01-01

    The gastrointestinal (GI) absorption factors and the biological retention times for polonium were determined for a group of 14 volunteers--seven men and seven women--from Saskatoon, Saskatchewan, Canada. Each volunteer consumed 2.0 kg of caribou meat containing known amounts of naturally occurring 210Po. Urine and faecal samples were collected for up to 65 days after meat consumption and analysed for 210Po. The average GI absorption factor for the 14 volunteers was 56 +/- 4% (range = 31-71%), not significantly different from the ICRP value of 50%. About 3% of absorbed polonium underwent prompt excretion by the urinary pathway. The remainder was retained by the body with a half-time >100 days, compared to the ICRP value of 50 days. The effect of these findings increases the dose estimate for ingestion of 210Po in food by a factor of 1.5 to 3.5. Thus, background doses to people consuming caribou and reindeer may be higher than previously thought.

  20. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiller, Mauritius; Dewji, Shaheen Azim

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  1. A probabilistic safety analysis of incidents in nuclear research reactors.

    PubMed

    Lopes, Valdir Maciel; Agostinho Angelo Sordi, Gian Maria; Moralles, Mauricio; Filho, Tufic Madi

    2012-06-01

    This work aims to evaluate the potential risks of incidents in nuclear research reactors. For its development, two databases of the International Atomic Energy Agency (IAEA) were used: the Research Reactor Data Base (RRDB) and the Incident Report System for Research Reactor (IRSRR). For this study, the probabilistic safety analysis (PSA) was used. To obtain the result of the probability calculations for PSA, the theory and equations in the paper IAEA TECDOC-636 were used. A specific program to analyse the probabilities was developed within the main program, Scilab 5.1.1. for two distributions, Fischer and chi-square, both with the confidence level of 90 %. Using Sordi equations, the maximum admissible doses to compare with the risk limits established by the International Commission on Radiological Protection (ICRP) were obtained. All results achieved with this probability analysis led to the conclusion that the incidents which occurred had radiation doses within the stochastic effects reference interval established by the ICRP-64.

  2. A comprehensive dose reconstruction methodology for former rocketdyne/atomics international radiation workers.

    PubMed

    Boice, John D; Leggett, Richard W; Ellis, Elizabeth Dupree; Wallace, Phillip W; Mumma, Michael; Cohen, Sarah S; Brill, A Bertrand; Chadda, Bandana; Boecker, Bruce B; Yoder, R Craig; Eckerman, Keith F

    2006-05-01

    Incomplete radiation exposure histories, inadequate treatment of internally deposited radionuclides, and failure to account for neutron exposures can be important uncertainties in epidemiologic studies of radiation workers. Organ-specific doses from lifetime occupational exposures and radionuclide intakes were estimated for an epidemiologic study of 5,801 Rocketdyne/Atomics International (AI) radiation workers engaged in nuclear technologies between 1948 and 1999. The entire workforce of 46,970 Rocketdyne/AI employees was identified from 35,042 Kardex work histories cards, 26,136 electronic personnel listings, and 14,189 radiation folders containing individual exposure histories. To obtain prior and subsequent occupational exposure information, the roster of all workers was matched against nationwide dosimetry files from the Department of Energy, the Nuclear Regulatory Commission, the Landauer dosimetry company, the U.S. Army, and the U.S. Air Force. Dosimetry files of other worker studies were also accessed. Computation of organ doses from radionuclide intakes was complicated by the diversity of bioassay data collected over a 40-y period (urine and fecal samples, lung counts, whole-body counts, nasal smears, and wound and incident reports) and the variety of radionuclides with documented intake including isotopes of uranium, plutonium, americium, calcium, cesium, cerium, zirconium, thorium, polonium, promethium, iodine, zinc, strontium, and hydrogen (tritium). Over 30,000 individual bioassay measurements, recorded on 11 different bioassay forms, were abstracted. The bioassay data were evaluated using ICRP biokinetic models recommended in current or upcoming ICRP documents (modified for one inhaled material to reflect site-specific information) to estimate annual doses for 16 organs or tissues taking into account time of exposure, type of radionuclide, and excretion patterns. Detailed internal exposure scenarios were developed and annual internal doses were derived

  3. Measuring Rates of Herbicide Metabolism in Dicot Weeds with an Excised Leaf Assay.

    PubMed

    Ma, Rong; Skelton, Joshua J; Riechers, Dean E

    2015-09-07

    In order to isolate and accurately determine rates of herbicide metabolism in an obligate-outcrossing dicot weed, waterhemp (Amaranthus tuberculatus), we developed an excised leaf assay combined with a vegetative cloning strategy to normalize herbicide uptake and remove translocation as contributing factors in herbicide-resistant (R) and -sensitive (S) waterhemp populations. Biokinetic analyses of organic pesticides in plants typically include the determination of uptake, translocation (delivery to the target site), metabolic fate, and interactions with the target site. Herbicide metabolism is an important parameter to measure in herbicide-resistant weeds and herbicide-tolerant crops, and is typically accomplished with whole-plant tests using radiolabeled herbicides. However, one difficulty with interpreting biokinetic parameters derived from whole-plant methods is that translocation is often affected by rates of herbicide metabolism, since polar metabolites are usually not mobile within the plant following herbicide detoxification reactions. Advantages of the protocol described in this manuscript include reproducible, accurate, and rapid determination of herbicide degradation rates in R and S populations, a substantial decrease in the amount of radiolabeled herbicide consumed, a large reduction in radiolabeled plant materials requiring further handling and disposal, and the ability to perform radiolabeled herbicide experiments in the lab or growth chamber instead of a greenhouse. As herbicide resistance continues to develop and spread in dicot weed populations worldwide, the excised leaf assay method developed and described herein will provide an invaluable technique for investigating non-target site-based resistance due to enhanced rates of herbicide metabolism and detoxification.

  4. Measuring Rates of Herbicide Metabolism in Dicot Weeds with an Excised Leaf Assay

    PubMed Central

    Ma, Rong; Skelton, Joshua J.; Riechers, Dean E.

    2015-01-01

    In order to isolate and accurately determine rates of herbicide metabolism in an obligate-outcrossing dicot weed, waterhemp (Amaranthus tuberculatus), we developed an excised leaf assay combined with a vegetative cloning strategy to normalize herbicide uptake and remove translocation as contributing factors in herbicide-resistant (R) and –sensitive (S) waterhemp populations. Biokinetic analyses of organic pesticides in plants typically include the determination of uptake, translocation (delivery to the target site), metabolic fate, and interactions with the target site. Herbicide metabolism is an important parameter to measure in herbicide-resistant weeds and herbicide-tolerant crops, and is typically accomplished with whole-plant tests using radiolabeled herbicides. However, one difficulty with interpreting biokinetic parameters derived from whole-plant methods is that translocation is often affected by rates of herbicide metabolism, since polar metabolites are usually not mobile within the plant following herbicide detoxification reactions. Advantages of the protocol described in this manuscript include reproducible, accurate, and rapid determination of herbicide degradation rates in R and S populations, a substantial decrease in the amount of radiolabeled herbicide consumed, a large reduction in radiolabeled plant materials requiring further handling and disposal, and the ability to perform radiolabeled herbicide experiments in the lab or growth chamber instead of a greenhouse. As herbicide resistance continues to develop and spread in dicot weed populations worldwide, the excised leaf assay method developed and described herein will provide an invaluable technique for investigating non-target site-based resistance due to enhanced rates of herbicide metabolism and detoxification. PMID:26383604

  5. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses

  6. Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

    NASA Technical Reports Server (NTRS)

    Sakaguchi, T.; Doke, T.; Hayashi, T.; Kikuchi, J.; Hasebe, N.; Kashiwagi, T.; Takashima, T.; Takahashi, K.; Nakano, T.; Nagaoka, S.; hide

    1997-01-01

    The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

  7. Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection.

    PubMed

    O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G

    2013-02-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.

  8. Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection

    PubMed Central

    Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G

    2015-01-01

    Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211

  9. Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms

    PubMed Central

    Na, Yong Hum; Zhang, Binquan; Zhang, Juying; Caracappa, Peter F; Xu, X George

    2012-01-01

    Computational phantoms representing workers and patients are essential in estimating organ doses from various occupational radiation exposures and medical procedures. Nearly all existing phantoms, however, were purposely designed to match internal and external anatomical features of the Reference Man as defined by the International Commission on Radiological Protection (ICRP). To reduce uncertainty in dose calculations caused by anatomical variations, a new generation of phantoms of varying organ and body sizes is needed. This paper presents detailed anatomical data in tables and graphs that are used to design such size-adjustable phantoms representing a range of adult individuals in terms of the body height, body weight and internal organ volume/mass. Two different sets of information are used to derive the phantom sets: (1) individual internal organ size and volume/mass distribution data derived from the recommendations of the ICRP in Publications 23 and 89 and (2) whole-body height and weight percentile data from the National Health and Nutrition Examination Survey (NHANES 1999–2002). The NHANES height and weight data for 19 year old males and females are used to estimate the distributions of individuals’ size, which is unknown, that corresponds to the ICRP organ and tissue distributions. This paper then demonstrates the usage of these anthropometric data in the development of deformable anatomical phantoms. A pair of phantoms—modeled entirely in mesh surfaces—of the adult male and female, RPI-adult male (AM) and RPI-adult female (AF) are used as the base for size-adjustable phantoms. To create percentile-specific phantoms from these two base phantoms, organ surface boundaries are carefully altered according to the tabulated anthropometric data. Software algorithms are developed to automatically match the organ volumes and masses with desired values. Finally, these mesh-based, percentile-specific phantoms are converted into voxel-based phantoms for Monte

  10. Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms

    NASA Astrophysics Data System (ADS)

    Hum Na, Yong; Zhang, Binquan; Zhang, Juying; Caracappa, Peter F.; Xu, X. George

    2010-07-01

    Computational phantoms representing workers and patients are essential in estimating organ doses from various occupational radiation exposures and medical procedures. Nearly all existing phantoms, however, were purposely designed to match internal and external anatomical features of the Reference Man as defined by the International Commission on Radiological Protection (ICRP). To reduce uncertainty in dose calculations caused by anatomical variations, a new generation of phantoms of varying organ and body sizes is needed. This paper presents detailed anatomical data in tables and graphs that are used to design such size-adjustable phantoms representing a range of adult individuals in terms of the body height, body weight and internal organ volume/mass. Two different sets of information are used to derive the phantom sets: (1) individual internal organ size and volume/mass distribution data derived from the recommendations of the ICRP in Publications 23 and 89 and (2) whole-body height and weight percentile data from the National Health and Nutrition Examination Survey (NHANES 1999-2002). The NHANES height and weight data for 19 year old males and females are used to estimate the distributions of individuals' size, which is unknown, that corresponds to the ICRP organ and tissue distributions. This paper then demonstrates the usage of these anthropometric data in the development of deformable anatomical phantoms. A pair of phantoms—modeled entirely in mesh surfaces—of the adult male and female, RPI-adult male (AM) and RPI-adult female (AF) are used as the base for size-adjustable phantoms. To create percentile-specific phantoms from these two base phantoms, organ surface boundaries are carefully altered according to the tabulated anthropometric data. Software algorithms are developed to automatically match the organ volumes and masses with desired values. Finally, these mesh-based, percentile-specific phantoms are converted into voxel-based phantoms for Monte

  11. 76 FR 53847 - New International Commission on Radiological Protection; Recommendations on the Annual Dose Limit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-30

    ... Radiological Protection; Recommendations on the Annual Dose Limit to the Lens of the Eye AGENCY: Nuclear... Protection (ICRP) recommendations for the limitation of annual dose to the lens of the eye. This significant... might be lower than previously considered. For the lens of the eye, the threshold in absorbed dose for...

  12. 75 FR 59160 - Radiation Protection Regulations and Guidance; Public Meetings and Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-27

    ..., which are based on a more diverse world population? Issue No. 2: Occupational Dose Limits The... between the ICRP values and the EPA values stems primarily from the use of a U.S. population cancer... worldwide population. In discussion with stakeholders to date, the majority have been generally in favor of...

  13. QUANTITATIVE PLUTONIUM MICRODISTRIBUTION IN BONE TISSUE OF VERTEBRA FROM A MAYAK WORKER

    PubMed Central

    Lyovkina, Yekaterina V.; Miller, Scott C.; Romanov, Sergey A.; Krahenbuhl, Melinda P.; Belosokhov, Maxim V.

    2010-01-01

    The purpose was to obtain quantitative data on plutonium microdistribution in different structural elements of human bone tissue for local dose assessment and dosimetric models validation. A sample of the thoracic vertebra was obtained from a former Mayak worker with a rather high plutonium burden. Additional information was obtained on occupational and exposure history, medical history, and measured plutonium content in organs. Plutonium was detected in bone sections from its fission tracks in polycarbonate film using neutron-induced autoradiography. Quantitative analysis of randomly selected microscopic fields on one of the autoradiographs was performed. Data included fission fragment tracks in different bone tissue and surface areas. Quantitative information on plutonium microdistribution in human bone tissue was obtained for the first time. From these data, quantitative relationship of plutonium decays in bone volume to decays on bone surface in cortical and trabecular fractions were defined as 2.0 and 0.4, correspondingly. The measured quantitative relationship of decays in bone volume to decays on bone surface does not coincide with recommended models for the cortical bone fraction by the International Commission on Radiological Protection. Biokinetic model parameters of extrapulmonary compartments might need to be adjusted after expansion of the data set on quantitative plutonium microdistribution in other bone types in human as well as other cases with different exposure patterns and types of plutonium. PMID:20838087

  14. Prediction of blood lead levels in children before and after remediation of soil samples in the upper Meza Valley, Slovenia.

    PubMed

    Jez, Erika; Lestan, Domen

    2015-10-15

    The Meza Valley, Slovenia, has been contaminated by Pb smelting, resulting in an epidemic of lead poisoning in childhood. The potential of remediation with EDTA soil washing to mitigate the risk from Pb poisoning was investigated by applying the Integrated Exposure Uptake Bio-kinetic (IEUBK) model. Soils from 79 locations were collected and the total and bio-accessible Pb concentrations were determined before and after extraction with 60 mmol kg(-1) EDTA. Extraction reduced the soil Pb concentration in towns of Mezica, Zerjav and Crna by 53, 67 and 62%, respectively, and the concentration of in vitro bio-accessible Pb in the simulated human gastric phase by 2.6-, 3.2- and 2.9-times, respectively. The predictions of the IEUBK model based on Pb contamination data were verified with data on blood Pb levels in children. The IEUBK model predicted that, after soil remediation, the number of locations at which the expected blood Pb level in children was higher than the stipulated 10 μg d L(-1) would decrease by 90, 38 and 91% in the towns of Mezica, Zerjav and Crna, respectively. The results confirmed the feasibility of soil washing with EDTA as an efficient remediation measure in Mezica and Crna and advice for soil capping/removal for the most polluted town of Zerjav. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Rich

    The transition metal yttrium (Y, atomic number 39) is chemically similar to elements in the lanthanide family (atomic numbers 57-71, lanthanum through lutetium) and is always present with the lanthanides in rare earth ores. Yttrium and the lanthanide holmium are particularly close chemical and physical analogues and are referred to as geochemical twins because they typically show little fractionation in geological material. Extensive measurements on rocks, soils, and meteorites indicate that the Y/Ho mass concentration ratio rarely falls far from the “chondritic” or “solar system” ratio of ~26. Our paper presents a new biokinetic model for yttrium in adult humansmore » and examines whether yttrium and holmium may be biological as well as geochemical twins. Collected data on yttrium and holmium in plants and human tissues do not allow precise derivations of Y/Ho concentration ratios but with occasional exceptions yield ratios that are reasonably consistent with chondritic values. Predictions of the time-dependent behavior of yttrium in adult humans based on the yttrium model presented here closely approximate predictions of the behavior of holmium based on a previously developed model for holmium. We know that yttrium and holmium are close biological analogues, but the available comparative data are too limited and imprecise to reveal whether there are any significant differences in their biological behavior.« less

  16. [Intelligence quotient loss in Mexican pottery artisan's children].

    PubMed

    Estrada-Sánchez, Daniel; Ericson, Bret; Juárez-Pérez, Cuauhtémoc Arturo; Aguilar-Madrid, Guadalupe; Hernández, Lina; Gualtero, Sandra; Caravanos, Jack

    2017-01-01

    In Mexico, artisans frequently use lead oxide or greta in order to produce utensils, which are destined to preparation and storage of food and drinks. Additionally, the risk of lead poisoning of artisans and their families is greater than in general population, and within these families, children are the most susceptible to lead poisoning. The aim of this study was to estimate IQ loss in Mexican children from potter families exposed to lead. Lead concentrations in soil were determined in 19 potter's homes that functioned as pottery workshops in seven Mexican states between 2009 and 2012. This information was used to estimate blood lead levels through the integrated exposure uptake biokinetic (IEUBK) model. The loss of IQ points was then estimated according to the Lanphear and Schwartz models. The mean lead concentration found in the workshops' soil was 1098.4 ppm. Blood lead levels estimated in children under 8 years old were 26.4 µg/dL and the loss of IQ points comprised from 7.13 to 8.84 points depending on the model. It is possible that 11 children from families of artisans in Mexico may be losing between 7.13 to 8.84 IQ points, due to lead exposure in their houses-workshops. This loss in IQ points could have important health, economic and social impacts.

  17. All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry.

    PubMed

    Kramer, R; Khoury, H J; Vieira, J W; Loureiro, E C M; Lima, V J M; Lima, F R A; Hoff, G

    2004-12-07

    The International Commission on Radiological Protection (ICRP) has created a task group on dose calculations, which, among other objectives, should replace the currently used mathematical MIRD phantoms by voxel phantoms. Voxel phantoms are based on digital images recorded from scanning of real persons by computed tomography or magnetic resonance imaging (MRI). Compared to the mathematical MIRD phantoms, voxel phantoms are true to the natural representations of a human body. Connected to a radiation transport code, voxel phantoms serve as virtual humans for which equivalent dose to organs and tissues from exposure to ionizing radiation can be calculated. The principal database for the construction of the FAX (Female Adult voXel) phantom consisted of 151 CT images recorded from scanning of trunk and head of a female patient, whose body weight and height were close to the corresponding data recommended by the ICRP in Publication 89. All 22 organs and tissues at risk, except for the red bone marrow and the osteogenic cells on the endosteal surface of bone ('bone surface'), have been segmented manually with a technique recently developed at the Departamento de Energia Nuclear of the UFPE in Recife, Brazil. After segmentation the volumes of the organs and tissues have been adjusted to agree with the organ and tissue masses recommended by ICRP for the Reference Adult Female in Publication 89. Comparisons have been made with the organ and tissue masses of the mathematical EVA phantom, as well as with the corresponding data for other female voxel phantoms. The three-dimensional matrix of the segmented images has eventually been connected to the EGS4 Monte Carlo code. Effective dose conversion coefficients have been calculated for exposures to photons, and compared to data determined for the mathematical MIRD-type phantoms, as well as for other voxel phantoms.

  18. Appropriate Use of Effective Dose in Radiation Protection and Risk Assessment.

    PubMed

    Fisher, Darrell R; Fahey, Frederic H

    2017-08-01

    Effective dose was introduced by the ICRP for the single, over-arching purpose of setting limits for radiation protection. Effective dose is a derived quantity or mathematical construct and not a physical, measurable quantity. The formula for calculating effective dose to a reference model incorporates terms to account for all radiation types, organ and tissue radiosensitivities, population groups, and multiple biological endpoints. The properties and appropriate applications of effective dose are not well understood by many within and outside the health physics profession; no other quantity in radiation protection has been more confusing or misunderstood. According to ICRP Publication 103, effective dose is to be used for "prospective dose assessment for planning and optimization in radiological protection, and retrospective demonstration of compliance for regulatory purposes." In practice, effective dose has been applied incorrectly to predict cancer risk among exposed persons. The concept of effective dose applies generally to reference models only and not to individual subjects. While conceived to represent a measure of cancer risk or heritable detrimental effects, effective dose is not predictive of future cancer risk. The formula for calculating effective dose incorporates committee-selected weighting factors for radiation quality and organ sensitivity; however, the organ weighting factors are averaged across all ages and both genders and thus do not apply to any specific individual or radiosensitive subpopulations such as children and young women. Further, it is not appropriate to apply effective dose to individual medical patients because patient-specific parameters may vary substantially from the assumptions used in generalized models. Also, effective dose is not applicable to therapeutic uses of radiation, as its mathematical underpinnings pertain only to observed late (stochastic) effects of radiation exposure and do not account for short-term adverse

  19. Monte Carlo estimation of radiation dose in organs of female and male adult phantoms due to FDG-F18 absorbed in the lungs

    NASA Astrophysics Data System (ADS)

    Belinato, Walmir; Santos, William S.; Silva, Rogério M. V.; Souza, Divanizia N.

    2014-03-01

    The determination of dose conversion factors (S values) for the radionuclide fluorodeoxyglucose (18F-FDG) absorbed in the lungs during a positron emission tomography (PET) procedure was calculated using the Monte Carlo method (MCNPX version 2.7.0). For the obtained dose conversion factors of interest, it was considered a uniform absorption of radiopharmaceutical by the lung of a healthy adult human. The spectrum of fluorine was introduced in the input data file for the simulation. The simulation took place in two adult phantoms of both sexes, based on polygon mesh surfaces called FASH and MASH with anatomy and posture according to ICRP 89. The S values for the 22 internal organs/tissues, chosen from ICRP No. 110, for the FASH and MASH phantoms were compared with the results obtained from a MIRD V phantoms called ADAM and EVA used by the Committee on Medical Internal Radiation Dose (MIRD). We observed variation of more than 100% in S values due to structural anatomical differences in the internal organs of the MASH and FASH phantoms compared to the mathematical phantom.

  20. EVALUATION OF EYE LENS DOSE TO WORKERS IN THE STEAM GENERATOR AT THE KOREAN OPTIMIZED POWER REACTOR 1000.

    PubMed

    Maeng, Sung Jun; Kim, Jinhwan; Cho, Gyuseong

    2018-03-15

    ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.

  1. Cosmic radiation in aviation: radiological protection of Air France aircraft crew.

    PubMed

    Desmaris, G

    2016-06-01

    Cosmic radiation in aviation has been a concern since the 1960s, and measurements have been taken for several decades by Air France. Results show that aircraft crew generally receive 3-4 mSv y(-1) for 750 boarding hours. Compliance with the trigger level of 6 mSv y(-1) is achieved by route selection. Work schedules can be developed for pregnant pilots to enable the dose to the fetus to be kept below 1 mSv. Crew members are informed of their exposition and the potential health impact. The upcoming International Commission on Radiological Protection (ICRP) report on cosmic radiation in aviation will provide an updated guidance. A graded approach proportionate with the time of exposure is recommended to implement the optimisation principle. The objective is to keep exposures of the most exposed aircraft members to reasonable levels. ICRP also recommends that information about cosmic radiation be disseminated, and that awareness about cosmic radiation be raised in order to favour informed decision-making by all concerned stakeholders. © The International Society for Prosthetics and Orthotics.

  2. NOTE: Monte Carlo evaluation of kerma in an HDR brachytherapy bunker

    NASA Astrophysics Data System (ADS)

    Pérez-Calatayud, J.; Granero, D.; Ballester, F.; Casal, E.; Crispin, V.; Puchades, V.; León, A.; Verdú, G.

    2004-12-01

    In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, maintaining a similar value along the length of the maze. The comparison of results from the aforementioned values with the Monte Carlo ones shows that results obtained using the albedo coefficient from the ICRP document more closely match those given by the Monte Carlo method, although the maximum value given by MC calculations is 30% greater.

  3. Development of the Updated Environmental Protection Agency Manual of Protective Action Guides (PAGS) and Protective Actions for Nuclear Incidents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, L.M.

    2008-07-01

    As a student intern with the United States Environmental Protection Agency (EPA) Headquarters, the author was trained in the National Response Plan (NRP) and assisted in the editing of the new (unpublished) EPA Protective Action Guides (PAGs) [1] which has been revised in light of the perceived post 9/11 potential for 'Dirty Bomb' and 'Improvised Nuclear Device' attacks on civilian areas. Technical aspects and the public policy aspects of developing the new guides are discussed. Early Phase initial responses discussed include: Notification of state and/or local authorities, immediate evacuation/sheltering prior to release information or measurements, monitoring of releases and exposuremore » rate measurements, estimation of dose consequences, implementation of protective actions in other areas. The new PAG clarifies the use of 1992 PAGs [2] for incidents other than nuclear power plant accidents, lowers projected thyroid dose for potassium iodine (KI), provides drinking water guidance, includes guidance for long-term site restoration, and updates dosimetry from ICRP 26 to ICRP 60. (authors)« less

  4. Ethical foundations of the radiological protection system.

    PubMed

    Cho, K W

    2016-06-01

    The International Commission on Radiological Protection (ICRP) has established Task Group 94 under Committee 4 to develop a report on the ethical foundations of the system of radiological protection. The aim of this report is to consolidate the basis of ICRP recommendations, to improve understanding of the system, and to provide a basis for communication on radiation risk and its perception. Through a series of workshops organised by the Commission in cooperation with the International Radiation Protection Association and its associate societies involving radiological protection professionals and specialists of ethics around the world, Task Group 94 has identified the key ethical and social values underpinning the system of radiological protection. The purpose of eliciting the ethical principles and values of the radiological protection system is not only to clarify the rationale for recommendations made by the Commission, but also to assist in discussions related to its practical implementation. A clear understanding of the ethical principles will help resolve dilemmas caused by potential conflicts in actions that might be considered, or decisions that must be made. © The International Society for Prosthetics and Orthotics.

  5. Radiation protection of people and the environment: developing a common approach.

    PubMed

    Pentreath, R J

    2002-03-01

    The problem with the current ICRP system of radiation protection, particularly for regulators, is that it fails to differentiate between the application of justification and optimisation to people in the circumstances of medical care or as part of a workforce, compared with their application to members of the general public in an environmental setting; plus the fact that it also fails to address the issue of potential impacts on the rest of the environment in any meaningful way. But if these deficiencies are to be addressed, it will be essential to consider how protection of both people and the living environment can be achieved within a broad philosophical framework, using complementary approaches, based on the same underlying scientific knowledge. This paper briefly examines some of these issues, and offers some suggestions for developing a common, or even a combined, approach. It draws upon recent suggestions made by the ICRP itself with regard to radiological protection, plus current activities-on several fronts-to provide an explicit basis for environmental protection.

  6. Evaluation of the effective dose during BNCT at TRR thermal column epithermal facility.

    PubMed

    Jarahi, Hossein; Kasesaz, Yaser; Saleh-Koutahi, Seyed Mohsen

    2016-04-01

    An epithermal neutron beam has been designed for Boron neutron Capture Therapy (BNCT) at the thermal column of Tehran Research Reactor (TRR) recently. In this paper the whole body effective dose, as well as the equivalent doses of several organs have been calculated in this facility using MCNP4C Monte Carlo code. The effective dose has been calculated by using the absorbed doses determined for each individual organ, taking into account the radiation and tissue weighting factors. The ICRP 110 whole body male phantom has been used as a patient model. It was found that the effective dose during BNCT of a brain tumor is equal to 0.90Sv. This effective dose may induce a 4% secondary cancer risk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Surface modification of zinc oxide nanoparticles with amorphous silica alters their fate in the circulation.

    PubMed

    Konduru, Nagarjun V; Murdaugh, Kimberly M; Swami, Archana; Jimenez, Renato J; Donaghey, Thomas C; Demokritou, Philip; Brain, Joseph D; Molina, Ramon M

    2016-08-01

    Nanoparticle (NP) pharmacokinetics and biological effects are influenced by many factors, especially surface physicochemical properties. We assessed the effects of an amorphous silica coating on the fate of zinc after intravenous (IV) injection of neutron activated uncoated (65)ZnO or silica-coated (65)ZnO NPs in male Wistar Han rats. Groups of IV-injected rats were sequentially euthanized, and 18 tissues were collected and analyzed for (65)Zn radioactivity. The protein coronas on each ZnO NP after incubation in rat plasma were analyzed by SDS-PAGE gel electrophoresis and mass spectrometry of selected gel bands. Plasma clearance for both NPs was biphasic with rapid initial and slower terminal clearance rates. Half-lives of plasma clearance of silica-coated (65)ZnO were shorter (initial - <1 min; terminal - 2.5 min) than uncoated (65)ZnO (initial - 1.9 min; terminal - 38 min). Interestingly, the silica-coated (65)ZnO group had higher (65)Zn associated with red blood cells and higher initial uptake in the liver. The (65)Zn concentrations in all the other tissues were significantly lower in the silica-coated than uncoated groups. We also found that the protein corona formed on silica-coated ZnO NPs had higher amounts of plasma proteins, particularly albumin, transferrin, A1 inhibitor 3, α-2-hs-glycoprotein, apoprotein E and α-1 antitrypsin. Surface modification with amorphous silica alters the protein corona, agglomerate size, and zeta potential of ZnO NPs, which in turn influences ZnO biokinetic behavior in the circulation. This emphasizes the critical role of the protein corona in the biokinetics, toxicology and nanomedical applications of NPs.

  8. Tritium ( 3 H) Retention In Mice: Administered As HTO, DTO or as 3 H-Labeled Amino-Acids.

    PubMed

    Priest, Nicholas D; Blimkie, Melinda S J; Wyatt, Heather; Bugden, Michelle; Bannister, Laura A; Gueguen, Yann; Jourdain, Jean-Rene; Klokov, Dmitry

    2017-05-01

    The objective of this study was to compare the biokinetics of injected H-labeled light (HTO) and heavy (DTO) water in CBA/CaJ mice and to compare the organ distribution and/or body content of H administered by chronic ingestion for 1 mo to C57Bl/6J mice, as either H-labeled water or H-labeled amino acids (glycine, alanine and proline). HTO and DTO were administered to CBA/CaJ mice by single intraperitoneal injection and body retention was determined for up to 384 h post-injection. Tritium-labeled water or H-labeled amino acids were given to C57Bl/6J mice ad libitum for 30 d in drinking water. Body content and organ distribution of H during the period of administration and subsequent to administration was determined by liquid scintillation counting. No differences were found between the biokinetics of HTO and DTO, indicating that data generated using HTO can be used to help assess the consequences of H releases from heavy water reactors. The results for H-water showed that the concentration of radionuclide in the mice reached a peak after about 10 d and dropped rapidly after the cessation of H administration. The maximum concentration reached was only 50% of that in the water consumed, indicating that mice receive a significant fraction of their water from respiration. Contrary to the findings of others, the pattern of H retention following the administration of a cocktail of the labeled amino acids was very little different from that found for the water. This is consistent with the suggestion that most of the ingested amino acids were rapidly metabolized, releasing water and carbon dioxide.

  9. ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.

    PubMed

    Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R

    2013-04-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.

  10. Radiological protection issues arising during and after the Fukushima nuclear reactor accident.

    PubMed

    González, Abel J; Akashi, Makoto; Boice, John D; Chino, Masamichi; Homma, Toshimitsu; Ishigure, Nobuhito; Kai, Michiaki; Kusumi, Shizuyo; Lee, Jai-Ki; Menzel, Hans-Georg; Niwa, Ohtsura; Sakai, Kazuo; Weiss, Wolfgang; Yamashita, Shunichi; Yonekura, Yoshiharu

    2013-09-01

    Following the Fukushima accident, the International Commission on Radiological Protection (ICRP) convened a task group to compile lessons learned from the nuclear reactor accident at the Fukushima Daiichi nuclear power plant in Japan, with respect to the ICRP system of radiological protection. In this memorandum the members of the task group express their personal views on issues arising during and after the accident, without explicit endorsement of or approval by the ICRP. While the affected people were largely protected against radiation exposure and no one incurred a lethal dose of radiation (or a dose sufficiently large to cause radiation sickness), many radiological protection questions were raised. The following issues were identified: inferring radiation risks (and the misunderstanding of nominal risk coefficients); attributing radiation effects from low dose exposures; quantifying radiation exposure; assessing the importance of internal exposures; managing emergency crises; protecting rescuers and volunteers; responding with medical aid; justifying necessary but disruptive protective actions; transiting from an emergency to an existing situation; rehabilitating evacuated areas; restricting individual doses of members of the public; caring for infants and children; categorising public exposures due to an accident; considering pregnant women and their foetuses and embryos; monitoring public protection; dealing with 'contamination' of territories, rubble and residues and consumer products; recognising the importance of psychological consequences; and fostering the sharing of information. Relevant ICRP Recommendations were scrutinised, lessons were collected and suggestions were compiled. It was concluded that the radiological protection community has an ethical duty to learn from the lessons of Fukushima and resolve any identified challenges. Before another large accident occurs, it should be ensured that inter alia: radiation risk coefficients of potential

  11. NASA Models of Space Radiation Induced Cancer, Circulatory Disease, and Central Nervous System Effects

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Chappell, Lori J.; Kim, Myung-Hee Y.

    2013-01-01

    The risks of late effects from galactic cosmic rays (GCR) and solar particle events (SPE) are potentially a limitation to long-term space travel. The late effects of highest concern have significant lethality including cancer, effects to the central nervous system (CNS), and circulatory diseases (CD). For cancer and CD the use of age and gender specific models with uncertainty assessments based on human epidemiology data for low LET radiation combined with relative biological effectiveness factors (RBEs) and dose- and dose-rate reduction effectiveness factors (DDREF) to extrapolate these results to space radiation exposures is considered the current "state-of-the-art". The revised NASA Space Risk Model (NSRM-2014) is based on recent radio-epidemiology data for cancer and CD, however a key feature of the NSRM-2014 is the formulation of particle fluence and track structure based radiation quality factors for solid cancer and leukemia risk estimates, which are distinct from the ICRP quality factors, and shown to lead to smaller uncertainties in risk estimates. Many persons exposed to radiation on earth as well as astronauts are life-time never-smokers, which is estimated to significantly modify radiation cancer and CD risk estimates. A key feature of the NASA radiation protection model is the classification of radiation workers by smoking history in setting dose limits. Possible qualitative differences between GCR and low LET radiation increase uncertainties and are not included in previous risk estimates. Two important qualitative differences are emerging from research studies. The first is the increased lethality of tumors observed in animal models compared to low LET radiation or background tumors. The second are Non- Targeted Effects (NTE), which include bystander effects and genomic instability, which has been observed in cell and animal models of cancer risks. NTE's could lead to significant changes in RBE and DDREF estimates for GCR particles, and the potential

  12. Comparison of organs' shapes with geometric and Zernike 3D moments.

    PubMed

    Broggio, D; Moignier, A; Ben Brahim, K; Gardumi, A; Grandgirard, N; Pierrat, N; Chea, M; Derreumaux, S; Desbrée, A; Boisserie, G; Aubert, B; Mazeron, J-J; Franck, D

    2013-09-01

    The morphological similarity of organs is studied with feature vectors based on geometric and Zernike 3D moments. It is particularly investigated if outliers and average models can be identified. For this purpose, the relative proximity to the mean feature vector is defined, principal coordinate and clustering analyses are also performed. To study the consistency and usefulness of this approach, 17 livers and 76 hearts voxel models from several sources are considered. In the liver case, models with similar morphological feature are identified. For the limited amount of studied cases, the liver of the ICRP male voxel model is identified as a better surrogate than the female one. For hearts, the clustering analysis shows that three heart shapes represent about 80% of the morphological variations. The relative proximity and clustering analysis rather consistently identify outliers and average models. For the two cases, identification of outliers and surrogate of average models is rather robust. However, deeper classification of morphological feature is subject to caution and can only be performed after cross analysis of at least two kinds of feature vectors. Finally, the Zernike moments contain all the information needed to re-construct the studied objects and thus appear as a promising tool to derive statistical organ shapes. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. EDITORIAL: Roberts Prize for the best paper published in 2011 Roberts Prize for the best paper published in 2011

    NASA Astrophysics Data System (ADS)

    Cherry, Simon; Ruffle, Jon

    2012-08-01

    The publishers of Physics in Medicine and Biology (PMB), IOP Publishing, in association with the journal owners, the Institute of Physics and Engineering in Medicine (IPEM), jointly award an annual prize for the best paper published in PMB during the previous year. The procedure for deciding the winner is a two-stage process. First, a shortlist of contenders is drawn up based on those papers that had the best referees' quality assessments, with a further quality check and endorsement by the Editorial Board. The papers on the shortlist are then reviewed by a specially convened IPEM committee consisting of members with fellow status. This committee reads the shortlisted papers and selects the winner. We have much pleasure in advising readers that the Roberts Prize for the best paper published in 2011 is awarded to Matthew Hough et al from the University of Florida, the Francis Marion University and the National Cancer Institute, USA for their paper on a comprehensive electron dosimetry model of skeletal tissues in the adult male: An image-based skeletal dosimetry model for the ICRP reference adult male—internal electron sources 2011 Phys. Med. Biol. 56 2309 Matthew Hough1, Perry Johnson1, Didier Rajon2, Derek Jokisch3, Choonsik Lee4 and Wesley Bolch1,5 1Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL, USA 2Department of Neurosurgery, University of Florida, Gainesville, FL, USA 3Department of Physics and Astronomy, Francis Marion University, Florence, SC, USA 4Radiation Epidemiology Branch, National Cancer Institute, Bethesda, MD, USA 5Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA Bone marrow is one of the more radiosensitive tissues in the human body and is housed within a complex structure of bone. This paper describes a comprehensive model of energy deposition by internal electron or beta particle emitters for the ICRP reference adult male based upon ex vivo CT and microCT images of

  14. Repeated inhalation exposure of rats to an anionic high molecular weight polymer aerosol: application of prediction models to better understand pulmonary effects and modes of action.

    PubMed

    Pauluhn, Jürgen

    2014-08-01

    Opposed to the wealth of information available for kinetic lung overload-related effects of poorly-soluble, low-toxicity particles (PSP), only limited information is available on biodegradable high molecular weight (HMW) organic polymers (molecular weight >20,000 Da). It is hypothesized that such types of polymers may exert a somewhat similar volume displacement-related mode of action in alveolar macrophages as PSP; however, with a differing biokinetics of the material retained in the lung. This polyurethane polymer was examined in single and 2-/13-week repeated exposure rat inhalation bioassays. The design of studies was adapted to that commonly applied for PSP. Rats were nose-only exposed for 6h/day for the respective study duration, followed by 1-, 2- and 4-week postexposure periods in the single, 2- and 13-week studies, respectively. While the findings in bronchoalveolar lavage (BAL) and histopathology were consistent with those typical of PSP, they appear to be superimposed by pulmonary phospholipidosis and a much faster reversibility of pulmonary inflammation. Kinetic modeling designed to estimate the accumulated lung burden of biopersistent PSP was also suitable to simulate the overload-dependent outcomes of this biodegradable polymer as long as the faster than normal elimination kinetics was observed and an additional 'void space volume' was added to adjust for the phagocytosed additional fraction of pulmonary phospholipids. The changes observed following repeated inhalation exposure appear to be consistent with a retention-related etiopathology (kinetic overload). In summary, this study did not reveal evidence of any polymer-specific pulmonary irritation or parenchymal injury. Taking all findings into account, 7 mg polymer/m(3) (exposure 6h/day, 5-days/week on 13 consecutive weeks) constitutes the point of departure for lower respiratory tract findings that represent a transitional state from effects attributable to an overload-dependent pulmonary

  15. Effect of solvent on in vitro dissolution: Summary of results for uranium, americium, and cobalt aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilmette, R.A.; Hoover, M.D.

    1995-12-01

    The revised 10 CFR Part 20 has adopted the ICRP Publication 30 method for calculating the committed effective dose equivalent from intakes of radionuclides. This dosimetry scheme requires knowledge or assumptions about the chemical form of the radionuclide, its particle size, and its known or assumed solubility. The solubility is classified as being either D (relatively soluble), W, or Y (relatively insoluble), depending on whether the material dissolves over periods of days, weeks, or years. Although Nuclear Regulatory Commission licensees may wish to take advantage of material-specific knowledge in order to adjust annual limits on intake and derived air concentrations,more » relatively few radioactive materials to which workers and the general population may be exposed have been adequately characterized either in terms of physicochemical form or solubility. Experimental measurement of solubility using some type of in vitro dissolution measurement system is therefore needed. However, there is currently no clear consensus regarding the appropriate design of in vitro dissolution systems, particularly when considering the range of different radionuclides to be studied, and the complexity of the biological mechanisms involved in the retention and clearance of inhaled deposited radioactive particles. The purpose of this study was to evaluate the effect of the several solvents on the dissolution of four test aerosols ({sup 57}Co{sub 3}O{sub 4}, {sup 241}AmO{sub 2}, ammonium diuranate [ADU], and U{sub 3}O{sub 8}) selected to encompass a variety of chemical and biochemical properties in vivo. The results of this study provide some guidance on the usefulness of in vitro dissolution tests for estimating the solubility of unknown radionuclide particles within the context of a simple model such as the class D, W, and Y formulation of ICRP 30.« less

  16. On effective dose for radiotherapy based on doses to nontarget organs and tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uselmann, Adam J., E-mail: ajuselmann@wisc.edu; Thomadsen, Bruce R.

    2015-02-15

    Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling.more » Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.« less

  17. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    DOE PAGES

    Veinot, K. G.; Y-12 National Security Complex, Oak Ridge, TN; Dewji, S. A.; ...

    2017-08-24

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients.more » In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.« less

  18. Ionizing radiation induced cataracts: Recent biological and mechanistic developments and perspectives for future research.

    PubMed

    Ainsbury, Elizabeth A; Barnard, Stephen; Bright, Scott; Dalke, Claudia; Jarrin, Miguel; Kunze, Sarah; Tanner, Rick; Dynlacht, Joseph R; Quinlan, Roy A; Graw, Jochen; Kadhim, Munira; Hamada, Nobuyuki

    The lens of the eye has long been considered as a radiosensitive tissue, but recent research has suggested that the radiosensitivity is even greater than previously thought. The 2012 recommendation of the International Commission on Radiological Protection (ICRP) to substantially reduce the annual occupational equivalent dose limit for the ocular lens has now been adopted in the European Union and is under consideration around the rest of the world. However, ICRP clearly states that the recommendations are chiefly based on epidemiological evidence because there are a very small number of studies that provide explicit biological, mechanistic evidence at doses <2Gy. This paper aims to present a review of recently published information on the biological and mechanistic aspects of cataracts induced by exposure to ionizing radiation (IR). The data were compiled by assessing the pertinent literature in several distinct areas which contribute to the understanding of IR induced cataracts, information regarding lens biology and general processes of cataractogenesis. Results from cellular and tissue level studies and animal models, and relevant human studies, were examined. The main focus was the biological effects of low linear energy transfer IR, but dosimetry issues and a number of other confounding factors were also considered. The results of this review clearly highlight a number of gaps in current knowledge. Overall, while there have been a number of recent advances in understanding, it remains unknown exactly how IR exposure contributes to opacification. A fuller understanding of how exposure to relatively low doses of IR promotes induction and/or progression of IR-induced cataracts will have important implications for prevention and treatment of this disease, as well as for the field of radiation protection. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  19. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veinot, K. G.; Y-12 National Security Complex, Oak Ridge, TN; Dewji, S. A.

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients.more » In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.« less

  20. Injury Risk Assessment of Non-Lethal Projectile Head Impacts

    PubMed Central

    Oukara, Amar; Nsiampa, Nestor; Robbe, Cyril; Papy, Alexandre

    2014-01-01

    Kinetic energy non-lethal projectiles are used to impart sufficient effect onto a person in order to deter uncivil or hazardous behavior with a low probability of permanent injury. Since their first use, real cases indicate that the injuries inflicted by such projectiles may be irreversible and sometimes lead to death, especially for the head impacts. Given the high velocities and the low masses involved in such impacts, the assessment approaches proposed in automotive crash tests and sports may not be appropriate. Therefore, there is a need of a specific approach to assess the lethality of these projectiles. In this framework, some recent research data referred in this article as “force wall approach” suggest the use of three lesional thresholds (unconsciousness, meningeal damages and bone damages) that depend on the intracranial pressure. Three corresponding critical impact forces are determined for a reference projectile. Based on the principle that equal rigid wall maximal impact forces will produce equal damage on the head, these limits can be determined for any other projectile. In order to validate the consistence of this innovative method, it is necessary to compare the results with other existing assessment methods. This paper proposes a comparison between the “force wall approach” and two different head models. The first one is a numerical model (Strasbourg University Finite Element Head Model-SUFEHM) from Strasbourg University; the second one is a mechanical surrogate (Ballistics Load Sensing Headform-BLSH) from Biokinetics. PMID:25400712

  1. Bioaccumulation dynamics and exposure routes of Cd and Cu among species of aquatic mayflies

    USGS Publications Warehouse

    Cain, D.; Croteau, M.-N.; Luoma, S.

    2011-01-01

    Consumption of periphyton is a potentially important route of metal exposure to benthic invertebrate grazers. The present study examined the bioaccumulation kinetics of dissolved and dietary Cd and Cu in five species of mayflies (class Insecta). Artificial stream water and benthic diatoms were separately labeled with enriched stable metal isotopes to determine physiological rate constants used by a biokinetic bioaccumulation model. The model was employed to simulate the effects of metal partitioning between water and food, expressed as the bioconcentration factor (BCF), as well as ingestion rate (IR) and metal assimilation efficiency of food (AE), on the relative importance of water and food to metal bioaccumulation. For all test species, the contribution of dietary uptake of Cd and Cu increased with BCF. For a given BCF, the contribution of food to the body burden increased with kuf, the metal uptake rate constant from food that combined variation in IR and AE. To explore the relative importance of water and diet exposure routes under field conditions, we used estimated site-specific aqueous free-ion concentrations to model Cd and Cu accumulation from aqueous exposure, exclusively. The predicted concentrations accounted for less than 5% of the observed concentrations, implying that most bioaccumulated metal was acquired from food. At least for the taxa considered in this study, we conclude that consumption of metal-contaminated periphyton can result in elevated metal body burdens and potentially increase the risk of metal toxicity. ?? 2011 SETAC.

  2. Evaluation of exposure to lead from drinking water in large buildings.

    PubMed

    Deshommes, Elise; Andrews, Robert C; Gagnon, Graham; McCluskey, Tim; McIlwain, Brad; Doré, Evelyne; Nour, Shokoufeh; Prévost, Michèle

    2016-08-01

    Lead results from 78,971 water samples collected in four Canadian provinces from elementary schools, daycares, and other large buildings using regulatory and investigative sampling protocols were analyzed to provide lead concentration distributions. Maximum concentrations reached 13,200 and 3890 μg/L following long and short stagnation periods respectively. High lead levels were persistent in some large buildings, reflected by high median values considering all taps, or specific to a few taps in the building. Simulations using the Integrated Uptake Biokinetic (IEUBK) model and lead concentrations after 30 min of stagnation in the dataset showed that, for most buildings, exposure to lead at the tap does not increase children's blood lead levels (BLLs). However, buildings or taps with extreme concentrations represent a significant health risk to young children attending school or daycare, as the estimated BLL far exceeded the 5 μg/dL threshold. Ingestion of water from specific taps could lead to acute exposure. Finally, for a few taps, the total daily lead intake reached the former World Health Organization (WHO) tolerable level for adults, suggesting potential health risks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. The use of ozone, ozone plus UV radiation, and aerobic microorganisms in the purification of some agro-industrial wastewaters.

    PubMed

    Benitez, F Javier; Acero, Juan L; Gonzalez, Teresa; Garcia, Juan

    2002-08-01

    The oxidation of the pollutant organic matter present in wastewaters generated during different stages in the black table-olive industry was investigated by using ozone alone or combined with UV radiation; by using aerobic microorganisms; and finally, by aerobic degradation of the previously ozonated wastewaters. In the ozonation processes, the removal of substrate (COD) and aromatic compounds, the decreases in BOD5 and pH, and the ozone consumed in the reaction were evaluated. A kinetic study was conducted that led to the evaluation of the stoichiometric ratio for the chemical reaction, as well as the rate constants for the substrate reduction and ozone disappearance. In the single aerobic degradation treatment, the evolution of substrate and biomass was monitored during the process, and a kinetic study was performed by applying the Contois model to the experimental data, giving the specific biokinetic constant, the cell yield coefficient, and the rate constant for the microorganism death phase. Finally, a combined process was performed, consisting in the aerobic degradation of pre-ozonated wastewaters, and the effect of such chemical pretreatment on the substrate removal and kinetic parameters of the later biological stage is discussed.

  4. Measurements of radon activity concentration in mouse tissues and organs.

    PubMed

    Ishimori, Yuu; Tanaka, Hiroshi; Sakoda, Akihiro; Kataoka, Takahiro; Yamaoka, Kiyonori; Mitsunobu, Fumihiro

    2017-05-01

    The purpose of this study is to investigate the biokinetics of inhaled radon, radon activity concentrations in mouse tissues and organs were determined after mice had been exposed to about 1 MBq/m 3 of radon in air. Radon activity concentrations in mouse blood and in other tissues and organs were measured with a liquid scintillation counter and with a well-type HP Ge detector, respectively. Radon activity concentration in mouse blood was 0.410 ± 0.016 Bq/g when saturated with 1 MBq/m 3 of radon activity concentration in air. In addition, average partition coefficients obtained were 0.74 ± 0.19 for liver, 0.46 ± 0.13 for muscle, 9.09 ± 0.49 for adipose tissue, and 0.22 ± 0.04 for other organs. With these results, a value of 0.414 for the blood-to-air partition coefficient was calculated by means of our physiologically based pharmacokinetic model. The time variation of radon activity concentration in mouse blood during exposure to radon was also calculated. All results are compared in detail with those found in the literature.

  5. Overview of air biofiltration - basic technology, economics and integration with other control technologies for effective treatment of air toxics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Govind, R.; Bishop, D.F.

    1996-12-31

    This paper provides an overview of air biofiltration with experimental data on the performance of peat/compost, pelletized packed bed and structured media biofilters. It is shown that use of high surface area per unit volume structured media results in higher contaminant treatment rates per unit biofilter volume. Peat/compost biofilters exhibit lower removal efficiencies at high (> 100 ppmv) inlet contaminant concentrations and require control of media moisture content. Increase of temperature results in increasing biodegradation rates. It is shown that use of structured ceramic media allows effective control of biomass buildup by continuous removal of biomass from the biofilter mediamore » and that the biomass removal rate depends on nutrient flowrate. An experimental system is presented which enables biofilm kinetics to be determined and a simple biofilter model is developed in this paper. A group contribution approach has been developed to estimate biokinetic parameter which allows biofiltration effectiveness to be determined for a variety of volatile organic compounds (VOCs). Finally, a procedure is presented, illustrated by an example, which is used to develop an integrated process for effective treatment of air contaminants. 22 refs., 12 figs., 4 tabs.« less

  6. Assessing exposure risks for freshwater tilapia species posed by mercury and methylmercury.

    PubMed

    Cheng, Yi-Hsien; Lin, Yi-Jun; You, Shu-Han; Yang, Ying-Fei; How, Chun Ming; Tseng, Yi-Ting; Chen, Wei-Yu; Liao, Chung-Min

    2016-08-01

    Waterborne and dietborne exposures of freshwater fish to mercury (Hg) in the forms of inorganic (Hg(II)) and organic (methylmercury or MeHg) affect their growth, development, and reproduction. However, an integrated mechanistic risk model framework to predict the impact of Hg(II)/MeHg on freshwater fish is lacking. Here, we integrated biokinetic, physiological and biogeographic data to calibrate and then establish key risk indices-hazardous quotient and exceedance risk-for freshwater tilapia species across geographic ranges of several major rivers in Taiwan. We found that Hg(II) burden was highest in kidney followed by gill, intestine, liver, blood, and muscle. Our results showed that Hg was less likely to pose mortality risk (mortality rate less than 5 %) for freshwater tilapia species. However, Hg is likely to pose the potential hazard to aquatic environments constrained by safety levels for aquatic organisms. Sensitivity analysis showed that amount of Hg accumulated in tilapia was most influenced by sediment uptake rate. Our approach opens up new possibilities for predicting future fish population health with the impacts of continued Hg exposure to provide information on which fish are deemed safe for human consumption.

  7. Efficacy of hair analysis for monitoring exposure to uranium: a mini-review.

    PubMed

    Joksić, Agnes Šömen; Katz, Sidney A

    2014-01-01

    In spite of the ease with which samples may be collected and the stability of the samples after collection, the use of hair mineral analysis for monitoring environmental exposures and evaluating heavy metal poisonings has remained controversial since its initial applications for these purposes in the early 1950s. Among the major arguments against using hair mineral analysis in general were the absence of biokinetic models and/or metabolic data that adequately described the incorporation of trace elements into the hair, the absence of correlations between the concentrations of trace elements in the hair and their concentrations in other tissues, the inability to distinguish between trace elements that were deposited in the hair endogenously and those that were deposited on the hair exogenously, the absence of reliable reference ranges for interpreting the results of hair mineral analysis and a lack of standard procedures for the collecting, preparing and analyzing the hair samples. The developments of the past two decades addressing these objections are reviewed here, and arguments supporting the use of hair analysis for monitoring environmental and/or occupational exposures to uranium are made on the basis of the information presented in this review.

  8. Radionuclide concentration processes in marine organisms: A comprehensive review.

    PubMed

    Carvalho, Fernando P

    2018-06-01

    The first measurements made of artificial radionuclides released into the marine environment did reveal that radionuclides are concentrated by marine biological species. The need to report radionuclide accumulation in biota in different conditions and geographical areas prompted the use of concentration factors as a convenient way to describe the accumulation of radionuclides in biota relative to radionuclide concentrations in seawater. Later, concentration factors became a tool in modelling radionuclide distribution and transfer in aquatic environments and to predicting radioactivity in organisms. Many environmental parameters can modify the biokinetics of accumulation and elimination of radionuclides in marine biota, but concentration factors remained a convenient way to describe concentration processes of radioactive and stable isotopes in aquatic organisms. Revision of CF values is periodically undertaken by international organizations, such as the International Atomic Energy Agency (IAEA), to make updated information available to the international community. A brief commented review of radionuclide concentration processes and concentration factors in marine organisms is presented for key groups of radionuclides such as fission products, activation products, transuranium elements, and naturally-occurring radionuclides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A set of 4D pediatric XCAT reference phantoms for multimodality research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Norris, Hannah, E-mail: Hannah.norris@duke.edu; Zhang, Yakun; Bond, Jason

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected tomore » best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized

  10. Software Development for Estimating the Conversion Factor (K-Factor) at Suitable Scan Areas, Relating the Dose Length Product to the Effective Dose.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi

    2017-05-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model

    PubMed Central

    Chu, Kuang Hua; Lin, Yu Ting; Hsu, Chia Chun; Chen, Chien Yi; Pan, Lung Kwang

    2012-01-01

    This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. PMID:22915780

  12. Synthesis of a 68Ga-Labeled Peptoid−Peptide Hybrid for Imaging of Neurotensin Receptor Expression in Vivo

    PubMed Central

    2010-01-01

    The neurotensin receptor subtype 1 (NTS1) represents an attractive molecular target for imaging various tumors. Positron emission tomography (PET) gained widespread importance due to its sensitivity. We combined the design of a metabolically stable neurotensin analogue with a 68Ga-radiolabeling approach. The 68Ga-labeled peptoid−peptide hybrid [68Ga]3 revealed high stability, specific tumor uptake (0.7%ID/g, 65 min p.i.), and advantageous biokinetics in vivo using HT29 tumor-bearing nude mice. Because of the ability to internalize into NTS1-expressing tumor cells, [68Ga]3 proved to be highly suitable for a reliable and practical visualization of NTS1-expressing tumors in vivo by small animal PET. PMID:24900199

  13. Synthesis of a (68)ga-labeled peptoid-Peptide hybrid for imaging of neurotensin receptor expression in vivo.

    PubMed

    Maschauer, Simone; Einsiedel, Jürgen; Hocke, Carsten; Hübner, Harald; Kuwert, Torsten; Gmeiner, Peter; Prante, Olaf

    2010-08-12

    The neurotensin receptor subtype 1 (NTS1) represents an attractive molecular target for imaging various tumors. Positron emission tomography (PET) gained widespread importance due to its sensitivity. We combined the design of a metabolically stable neurotensin analogue with a (68)Ga-radiolabeling approach. The (68)Ga-labeled peptoid-peptide hybrid [(68)Ga]3 revealed high stability, specific tumor uptake (0.7%ID/g, 65 min p.i.), and advantageous biokinetics in vivo using HT29 tumor-bearing nude mice. Because of the ability to internalize into NTS1-expressing tumor cells, [(68)Ga]3 proved to be highly suitable for a reliable and practical visualization of NTS1-expressing tumors in vivo by small animal PET.

  14. Biokinetics of different-shaped copper oxide nanoparticles in the freshwater gastropod, Potamopyrgus antipodarum

    USGS Publications Warehouse

    Ramskov, Tina; Croteau, Marie-Noele; Forbes, Valery E.; Selck, Henriette

    2015-01-01

    Sediment is recognized as a major environmental sink for contaminants, including engineered nanoparticles (NPs). Consequently, sediment-living organisms are likely to be exposed to NPs. There is evidence that both accumulation and toxicity of metal NPs to sediment-dwellers increase with decreasing particle size, although NP size does not always predict effects. In contrast, not much is known about the influence of particle shape on bioaccumulation and toxicity. Here, we examined the influence of copper oxide (CuO) NP shape (rods, spheres, and platelets) on their bioaccumulation kinetics and toxicity to the sediment-dwelling gastropod, Potamopyrgus antipodarum. The influence of Cu added as CuCl2 (i.e., aqueous Cu treatment) was also examined. Exposure to sediment mixed with aqueous Cu or with different-shaped CuO NPs at an average measured exposure concentration of 207 μg Cu per g dry weight sediment for 14 days did not significantly affect snail mortality. However, growth decreased for snails exposed to sediment amended with CuO NP spheres and platelets. P. antipodarum accumulated Cu from all Cu forms/shapes in significant amounts compared to control snails. In addition, once accumulated, Cu was efficiently retained (i.e., elimination rate constants were generally not significantly different from zero). Consequently, snails are likely to concentrate Cu over time, from both aqueous and NP sources, resulting in a high potential for toxicity.

  15. Human variability in mercury toxicokinetics and steady state biomarker ratios.

    PubMed

    Bartell, S M; Ponce, R A; Sanga, R N; Faustman, E M

    2000-10-01

    Regulatory guidelines regarding methylmercury exposure depend on dose-response models relating observed mercury concentrations in maternal blood, cord blood, and maternal hair to developmental neurobehavioral endpoints. Generalized estimates of the maternal blood-to-hair, blood-to-intake, or hair-to-intake ratios are necessary for linking exposure to biomarker-based dose-response models. Most assessments have used point estimates for these ratios; however, significant interindividual and interstudy variability has been reported. For example, a maternal ratio of 250 ppm in hair per mg/L in blood is commonly used in models, but a 1990 WHO review reports mean ratios ranging from 140 to 370 ppm per mg/L. To account for interindividual and interstudy variation in applying these ratios to risk and safety assessment, some researchers have proposed representing the ratios with probability distributions and conducting probabilistic assessments. Such assessments would allow regulators to consider the range and like-lihood of mercury exposures in a population, rather than limiting the evaluation to an estimate of the average exposure or a single conservative exposure estimate. However, no consensus exists on the most appropriate distributions for representing these parameters. We discuss published reviews of blood-to-hair and blood-to-intake steady state ratios for mercury and suggest statistical approaches for combining existing datasets to form generalized probability distributions for mercury distribution ratios. Although generalized distributions may not be applicable to all populations, they allow a more informative assessment than point estimates where individual biokinetic information is unavailable. Whereas development and use of these distributions will improve existing exposure and risk models, additional efforts in data generation and model development are required.

  16. Lung-clearance classification of radionuclides in calcined phosphate rock dust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalkwarf, D.R.; Jackson, P.O.

    1984-08-01

    Lung-clearance classifications for /sup 210/Pb and /sup 210/Po in airborne dust from elemental phosphorus plants were estimated for use with the lung clearance model proposed by the ICRP Task Group on Lung Dynamics. Estimates were based on measurements of dissolution rates for these radionuclides from sized dust samples into simulated lung fluid at 37/sup 0/C. The estimates were expressed in the classification terms of the model, i.e., D, W and Y, indicating lung clearance half-times of 0 to 10 days, 11 to 100 days and more than 100 days. Dust samples were obtained from two plants in the western Unitedmore » States, and dissolution trials were conducted on fractions containing particles with aerodynamic equivalent diameters (AED) of 0 to 3 ..mu..m and of 3 to 10 ..mu..m. The /sup 210/Pb and /sup 210/Po in each of these fractions were classified 100% Class Y. The specific activities of both radionuclides increased with decreasing AED of the particles. 11 references, 1 figure, 4 tables.« less

  17. Simulation of the GCR spectrum in the Mars curiosity rover's RAD detector using MCNP6

    NASA Astrophysics Data System (ADS)

    Ratliff, Hunter N.; Smith, Michael B. R.; Heilbronn, Lawrence

    2017-08-01

    The paper presents results from MCNP6 simulations of galactic cosmic ray (GCR) propagation down through the Martian atmosphere to the surface and comparison with RAD measurements made there. This effort is part of a collaborative modeling workshop for space radiation hosted by Southwest Research Institute (SwRI). All modeling teams were tasked with simulating the galactic cosmic ray (GCR) spectrum through the Martian atmosphere and the Radiation Assessment Detector (RAD) on-board the Curiosity rover. The detector had two separate particle acceptance angles, 4π and 30 ° off zenith. All ions with Z = 1 through Z = 28 were tracked in both scenarios while some additional secondary particles were only tracked in the 4π cases. The MCNP6 4π absorbed dose rate was 307.3 ± 1.3 μGy/day while RAD measured 233 μGy/day. Using the ICRP-60 dose equivalent conversion factors built into MCNP6, the simulated 4π dose equivalent rate was found to be 473.1 ± 2.4 μSv/day while RAD reported 710 μSv/day.

  18. Biokinetics of radiocesium depuration in marine fish inhabiting the vicinity of the Fukushima Dai-ichi Nuclear Power Plant.

    PubMed

    Tateda, Yutaka; Tsumune, Daisuke; Misumi, Kazuhiro; Aono, Tatsuo; Kanda, Jota; Ishimaru, Takashi

    2017-01-01

    Radiocesium ( 134 Cs and 137 Cs) released from the Fukushima Dai-ichi Nuclear Power Plant (1FNPP) accident contaminated the fish inhabiting the port of 1FNPP. Radiocesium concentrations in some fishes, especially rockfish, have still remained at elevated levels, while concentrations in olive flounder have decreased in 2015 to the level which is close to the Japanese regulatory limit for seafood products (0.1 kBq kg-wet -1 ). In this study a dynamic food chain transfer model was applied to reconstruct radiocesium levels in olive flounder residing around the port area. As a result, the observed 137 Cs concentrations in olive flounder collected from the port could be explained by the simulated values in the fish, using the seawater level records at the port entrance. The reconstructed maximum 134 + 137 Cs concentration in olive flounder inhabiting the port area was 72 kB kg-wet -1 in July 2011 and the ecological half-life (EHL) was estimated as being 180 days during the period of 2014-2015. Short term simulation which assumed that the coastal water fish swam into the port during 1 month, demonstrated that the radiocesium level in the olive flounder may become equivalent to the depurated level in the fish which were initially contaminated. This result indicated that the increase of radiocesium levels in wandering fish is unlikely to change total radiocesium concentrations in the olive flounder. In this sense, the radiocesium levels in the olive flounder of the port area can be interpreted as being convergent in 2015, regardless of the differences in their contamination histories. On the other hand, the higher 137 Cs concentrations in fat greenling, compared to the olive flounder, can be attributed to a history of exposure to the contaminated seawater and food at the inner area of the port, such as the shallow draft quay and seawall area. As a result of the reconstructed initial higher radiocesium concentration, constrained by exposure history at the inner area of

  19. Effects of Cobalt-60 Exposure on Health of Taiwan Residents Suggest New Approach Needed in Radiation Protection

    PubMed Central

    Chen, W.L.; Luan, Y.C.; Shieh, M.C.; Chen, S.T.; Kung, H.T.; Soong, K.L; Yeh, Y.C.; Chou, T.S.; Mong, S.H.; Wu, J.T.; Sun, C.P.; Deng, W.P.; Wu, M.F.; Shen, M.L.

    2007-01-01

    The conventional approach for radiation protection is based on the ICRP's linear, no threshold (LNT) model of radiation carcinogenesis, which implies that ionizing radiation is always harmful, no matter how small the dose. But a different approach can be derived from the observed health effects of the serendipitous contamination of 1700 apartments in Taiwan with cobalt-60 (T1/2 = 5.3 y). This experience indicates that chronic exposure of the whole body to low-dose-rate radiation, even accumulated to a high annual dose, may be beneficial to human health. Approximately 10,000 people occupied these buildings and received an average radiation dose of 0.4 Sv, unknowingly, during a 9–20 year period. They did not suffer a higher incidence of cancer mortality, as the LNT theory would predict. On the contrary, the incidence of cancer deaths in this population was greatly reduced—to about 3 per cent of the incidence of spontaneous cancer death in the general Taiwan public. In addition, the incidence of congenital malformations was also reduced—to about 7 per cent of the incidence in the general public. These observations appear to be compatible with the radiation hormesis model. Information about this Taiwan experience should be communicated to the public worldwide to help allay its fear of radiation and create a positive impression about important radiation applications. Expenditures of many billions of dollars in nuclear reactor operation could be saved and expansion of nuclear electricity generation could be facilitated. In addition, this knowledge would encourage further investigation and implementation of very important applications of total-body, low-dose irradiation to treat and cure many illnesses, including cancer. The findings of this study are such a departure from expectations, based on ICRP criteria, that we believe that they ought to be carefully reviewed by other, independent organizations and that population data not available to the authors be provided

  20. Lung and stomach cancer associations with groundwater radon in North Carolina, USA

    PubMed Central

    Messier, Kyle P; Serre, Marc L

    2017-01-01

    Abstract Background: The risk of indoor air radon for lung cancer is well studied, but the risks of groundwater radon for both lung and stomach cancer are much less studied, and with mixed results. Methods: Geomasked and geocoded stomach and lung cancer cases in North Carolina from 1999 to 2009 were obtained from the North Carolina Central Cancer Registry. Models for the association with groundwater radon and multiple confounders were implemented at two scales: (i) an ecological model estimating cancer incidence rates at the census tract level; and (ii) a case-only logistic model estimating the odds that individual cancer cases are members of local cancer clusters. Results: For the lung cancer incidence rate model, groundwater radon is associated with an incidence rate ratio of 1.03 [95% confidence interval (CI) = 1.01, 1.06] for every 100 Bq/l increase in census tract averaged concentration. For the cluster membership models, groundwater radon exposure results in an odds ratio for lung cancer of 1.13 (95% CI = 1.04, 1.23) and for stomach cancer of 1.24 (95% CI = 1.03, 1.49), which means groundwater radon, after controlling for multiple confounders and spatial auto-correlation, increases the odds that lung and stomach cancer cases are members of their respective cancer clusters. Conclusion: Our study provides epidemiological evidence of a positive association between groundwater radon exposure and lung cancer incidence rates. The cluster membership model results find groundwater radon increases the odds that both lung and stomach cancer cases occur within their respective cancer clusters. The results corroborate previous biokinetic and mortality studies that groundwater radon is associated with increased risk for lung and stomach cancer. PMID:27639278