Sample records for identification devices effectiveness

  1. 21 CFR 830.300 - Devices subject to device identification data submission requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Devices subject to device identification data submission requirements. 830.300 Section 830.300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Identification Database § 830.300 Devices subject to device identification data submission requirements. (a) In...

  2. Device-Free Passive Identity Identification via WiFi Signals.

    PubMed

    Lv, Jiguang; Yang, Wu; Man, Dapeng

    2017-11-02

    Device-free passive identity identification attracts much attention in recent years, and it is a representative application in sensorless sensing. It can be used in many applications such as intrusion detection and smart building. Previous studies show the sensing potential of WiFi signals in a device-free passive manner. It is confirmed that human's gait is unique from each other similar to fingerprint and iris. However, the identification accuracy of existing approaches is not satisfactory in practice. In this paper, we present Wii, a device-free WiFi-based Identity Identification approach utilizing human's gait based on Channel State Information (CSI) of WiFi signals. Principle Component Analysis (PCA) and low pass filter are applied to remove the noises in the signals. We then extract several entities' gait features from both time and frequency domain, and select the most effective features according to information gain. Based on these features, Wii realizes stranger recognition through Gaussian Mixture Model (GMM) and identity identification through a Support Vector Machine (SVM) with Radial Basis Function (RBF) kernel. It is implemented using commercial WiFi devices and evaluated on a dataset with more than 1500 gait instances collected from eight subjects walking in a room. The results indicate that Wii can effectively recognize strangers and can achieves high identification accuracy with low computational cost. As a result, Wii has the potential to work in typical home security systems.

  3. Device-Free Passive Identity Identification via WiFi Signals

    PubMed Central

    Yang, Wu; Man, Dapeng

    2017-01-01

    Device-free passive identity identification attracts much attention in recent years, and it is a representative application in sensorless sensing. It can be used in many applications such as intrusion detection and smart building. Previous studies show the sensing potential of WiFi signals in a device-free passive manner. It is confirmed that human’s gait is unique from each other similar to fingerprint and iris. However, the identification accuracy of existing approaches is not satisfactory in practice. In this paper, we present Wii, a device-free WiFi-based Identity Identification approach utilizing human’s gait based on Channel State Information (CSI) of WiFi signals. Principle Component Analysis (PCA) and low pass filter are applied to remove the noises in the signals. We then extract several entities’ gait features from both time and frequency domain, and select the most effective features according to information gain. Based on these features, Wii realizes stranger recognition through Gaussian Mixture Model (GMM) and identity identification through a Support Vector Machine (SVM) with Radial Basis Function (RBF) kernel. It is implemented using commercial WiFi devices and evaluated on a dataset with more than 1500 gait instances collected from eight subjects walking in a room. The results indicate that Wii can effectively recognize strangers and can achieves high identification accuracy with low computational cost. As a result, Wii has the potential to work in typical home security systems. PMID:29099091

  4. 21 CFR 830.310 - Information required for unique device identification.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Information required for unique device identification. 830.310 Section 830.310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... Identification Database § 830.310 Information required for unique device identification. The contact for device...

  5. 21 CFR 830.320 - Submission of unique device identification information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Identification Database § 830.320 Submission of unique device identification information. (a) Designation of... Unique Device Identification Database (GUDID) in a format that we can process, review, and archive...

  6. 21 CFR 830.340 - Voluntary submission of ancillary device identification information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Identification Database § 830.340 Voluntary submission of ancillary device identification information. (a) You may not submit any information to the Global Unique Device Identification Database (GUDID) other than...

  7. Analysis of metallic medical devices after cremation: The importance in identification.

    PubMed

    De Angelis, Danilo; Collini, Federica; Muccino, Enrico; Cappella, Annalisa; Sguazza, Emanuela; Mazzucchi, Alessandra; Cattaneo, Cristina

    2017-03-01

    The recovery of a charred cadaver raises many issues concerning personal identification; the presence of prosthetic materials may provide very important and decisive information. Who is involved in the recovery of a charred body or of burnt human fragments, should therefore be able to recognize medical devices even if modified by fire effects. Metallic residues (585kg) that came from 2785 cremations were studied. Medical devices were then divided by type and material in order to esteem the representativeness of each typology. The study illustrates the great presence of metal medical devices that could be of great help in identifying bodies and underlines that metallic medical devices types and morphology should be known by forensic practitioner involved in identification cases and that this kind of material can still be identified by physician and dentists, even if exposed to very high temperatures. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  8. 21 CFR 866.2660 - Microorganism differentiation and identification device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microorganism differentiation and identification device. 866.2660 Section 866.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices...

  9. 21 CFR 866.2660 - Microorganism differentiation and identification device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microorganism differentiation and identification device. 866.2660 Section 866.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices...

  10. 21 CFR 866.2660 - Microorganism differentiation and identification device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microorganism differentiation and identification device. 866.2660 Section 866.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices...

  11. 21 CFR 866.2660 - Microorganism differentiation and identification device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microorganism differentiation and identification device. 866.2660 Section 866.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices...

  12. 21 CFR 866.2660 - Microorganism differentiation and identification device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microorganism differentiation and identification device. 866.2660 Section 866.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices...

  13. Device for detection and identification of carbon- and nitrogen-containing materials

    DOEpatents

    Karev, Alexander Ivanovich; Raevsky, Valery Georgievich; Dzhilavyan, Leonid Zavenovich; Laptev, Valery Dmitrievich; Pakhomov, Nikolay Ivanovich; Shvedunov, Vasily Ivanovich; Rykalin, Vladimir Ivanovich; Brothers, Louis Joseph; Wilhide, Larry K

    2014-03-25

    A device for detection and identification of carbon- and nitrogen-containing materials is described. In particular, the device performs the detection and identification of carbon- and nitrogen-containing materials by photo-nuclear detection. The device may comprise a race-track microtron, a breaking target, and a water-filled Cherenkov radiation counter.

  14. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    PubMed

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  15. Portable source identification device

    NASA Astrophysics Data System (ADS)

    Andersen, Eric S.; Samuel, Todd J.; Gervais, Kevin L.

    2005-05-01

    U.S. Customs and Border Protection (CBP) is the primary enforcement agency protecting the nation"s ports of entry. CBP is enhancing its capability to interdict the illicit import of nuclear and radiological materials and devices that may be used by terrorists. Pacific Northwest National Laboratory (PNNL) is providing scientific and technical support to CBP in their goal to enable rapid deployment of nuclear and radiation detection systems at U. S. ports of entry to monitor 100% of the incoming international traffic and cargo while not adversely impacting the operations or throughput of the ports. As the deployment of radiation detection systems proceeds, there is a need to adapt the baseline radiation portal monitor (RPM) system technology to operations at these diverse ports of entry. When screening produces an alarm in the primary inspection RPM, the alarming vehicle is removed from the flow of commerce and the alarm is typically confirmed in a secondary inspection RPM. The portable source identification device (PSID) is a radiation sensor panel (RSP), based on thallium-doped sodium iodide (NaI(Tl)) scintillation detector and gamma spectroscopic analysis hardware and software, mounted on a scissor lift on a small truck. The lift supports a box containing a commercial off-the-shelf (COTS) sodium iodide detector that provides real-time isotopic identification, including neutron detectors to interdict Weapons of Mass Destruction (WMD) and radiation dispersion devices (RDD). The scissor lift will lower the detectors to within a foot off the ground and raise them to approximately 24 feet (7.3 m) in the air, allowing a wide vertical scanning range.

  16. 21 CFR 830.330 - Times for submission of unique device identification information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Times for submission of unique device identification information. 830.330 Section 830.330 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Identification Database § 830.330 Times for submission of unique device identification information. (a) The...

  17. Toward the development of portable miniature intelligent electronic color identification devices

    NASA Astrophysics Data System (ADS)

    Nicolau, Dan V., Jr.; Livingston, Peter; Jahshan, David; Evans, Rob

    2004-03-01

    The identification and differentiation of colours is a relatively problematic task for colour-impaired and partially vision-impaired persons and an impossible one for completely blind. In various contexts, this leads to a loss of independence or an increased risk of harm. The identification of colour using optoelectronic devices, on the other hand, can be done precisely and inexpensively. Additionally, breakthroughs in miniaturising and integrating colour sensors into biological systems may lead to significant advances in electronic implants for alleviating blindness. Here we present a functional handheld device developed for the identification of colour, intended for use by the vision-impaired. We discuss the features and limitations of the device and describe in detail one target application - the identification of different banknote denominations by the blind.

  18. Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture

    DOEpatents

    Steele, Kerry D [Kennewick, WA; Anderson, Gordon A [Benton City, WA; Gilbert, Ronald W [Morgan Hill, CA

    2011-02-01

    Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture are described. In one aspect, a communications device identification method includes providing identification information regarding a group of wireless identification devices within a wireless communications range of a reader, using the provided identification information, selecting one of a plurality of different search procedures for identifying unidentified ones of the wireless identification devices within the wireless communications range, and identifying at least some of the unidentified ones of the wireless identification devices using the selected one of the search procedures.

  19. Implications of User Identification Devices (UIDS) for the United States Navy

    DTIC Science & Technology

    2001-09-01

    radio technology, and this includes all mobile and cordless telecommunication devices . “Total worldwide sales of RFID systems for the year 2000 have... theft . A person who has stolen the user identification device of another and uses it to impersonate him or her, serves as a common example. Since user...IDENTIFICATION DEVICES (UIDS) FOR THE UNITED STATES NAVY by Letitia D. Haynes September 2001 Thesis Advisor: Cynthia Irvine Associate

  20. 21 CFR 801.57 - Discontinuation of legacy FDA identification numbers assigned to devices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Discontinuation of legacy FDA identification... Device Identification § 801.57 Discontinuation of legacy FDA identification numbers assigned to devices... been assigned an FDA labeler code to facilitate use of NHRIC or NDC numbers may continue to use that...

  1. 21 CFR 830.350 - Correction of information submitted to the Global Unique Device Identification Database.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Unique Device Identification Database. 830.350 Section 830.350 Food and Drugs FOOD AND DRUG... Global Unique Device Identification Database § 830.350 Correction of information submitted to the Global Unique Device Identification Database. (a) If FDA becomes aware that any information submitted to the...

  2. High-throughput Identification of Bacteria Repellent Polymers for Medical Devices

    PubMed Central

    Wu, Mei; Hardman, Ailsa; Lilienkampf, Annamaria; Pernagallo, Salvatore; Blakely, Garry; Swann, David G.; Bradley, Mark; Gallagher, Maurice P.

    2016-01-01

    Medical devices are often associated with hospital-acquired infections, which place enormous strain on patients and the healthcare system as well as contributing to antimicrobial resistance. One possible avenue for the reduction of device-associated infections is the identification of bacteria-repellent polymer coatings for these devices, which would prevent bacterial binding at the initial attachment step. A method for the identification of such repellent polymers, based on the parallel screening of hundreds of polymers using a microarray, is described here. This high-throughput method resulted in the identification of a range of promising polymers that resisted binding of various clinically relevant bacterial species individually and also as multi-species communities. One polymer, PA13 (poly(methylmethacrylate-co-dimethylacrylamide)), demonstrated significant reduction in attachment of a number of hospital isolates when coated onto two commercially available central venous catheters. The method described could be applied to identify polymers for a wide range of applications in which modification of bacterial attachment is important. PMID:27842360

  3. 77 FR 40735 - Unique Device Identification System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ... Identification System AGENCY: Food and Drug Administration, HHS. ACTION: Proposed rule. SUMMARY: The Food and... Regulatory Action This rule is intended to substantially reduce existing obstacles to the adequate... appropriate, better-focused, corrective action. The rule will also require dates on medical device labels to...

  4. 78 FR 58545 - Global Unique Device Identification Database; Draft Guidance for Industry; Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ...] Global Unique Device Identification Database; Draft Guidance for Industry; Availability AGENCY: Food and... the availability of the draft guidance entitled ``Global Unique Device Identification Database (GUDID... manufacturer) will interface with the GUDID, as well as information on the database elements that must be...

  5. 7 CFR 54.18 - Custody of identification devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... provide a metal cabinet(s) or locker(s) for the secure storage of official meat grading equipment and identification devices for each Federal meat grader assigned to their establishment. Such cabinet(s) or locker(s...

  6. 7 CFR 54.18 - Custody of identification devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... provide a metal cabinet(s) or locker(s) for the secure storage of official meat grading equipment and identification devices for each Federal meat grader assigned to their establishment. Such cabinet(s) or locker(s...

  7. 7 CFR 54.18 - Custody of identification devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... provide a metal cabinet(s) or locker(s) for the secure storage of official meat grading equipment and identification devices for each Federal meat grader assigned to their establishment. Such cabinet(s) or locker(s...

  8. 7 CFR 54.18 - Custody of identification devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... provide a metal cabinet(s) or locker(s) for the secure storage of official meat grading equipment and identification devices for each Federal meat grader assigned to their establishment. Such cabinet(s) or locker(s...

  9. 7 CFR 54.18 - Custody of identification devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... provide a metal cabinet(s) or locker(s) for the secure storage of official meat grading equipment and identification devices for each Federal meat grader assigned to their establishment. Such cabinet(s) or locker(s...

  10. Facial expression identification using 3D geometric features from Microsoft Kinect device

    NASA Astrophysics Data System (ADS)

    Han, Dongxu; Al Jawad, Naseer; Du, Hongbo

    2016-05-01

    Facial expression identification is an important part of face recognition and closely related to emotion detection from face images. Various solutions have been proposed in the past using different types of cameras and features. Microsoft Kinect device has been widely used for multimedia interactions. More recently, the device has been increasingly deployed for supporting scientific investigations. This paper explores the effectiveness of using the device in identifying emotional facial expressions such as surprise, smile, sad, etc. and evaluates the usefulness of 3D data points on a face mesh structure obtained from the Kinect device. We present a distance-based geometric feature component that is derived from the distances between points on the face mesh and selected reference points in a single frame. The feature components extracted across a sequence of frames starting and ending by neutral emotion represent a whole expression. The feature vector eliminates the need for complex face orientation correction, simplifying the feature extraction process and making it more efficient. We applied the kNN classifier that exploits a feature component based similarity measure following the principle of dynamic time warping to determine the closest neighbors. Preliminary tests on a small scale database of different facial expressions show promises of the newly developed features and the usefulness of the Kinect device in facial expression identification.

  11. Detection of low frequency external electronic identification devices using commercial panel readers.

    PubMed

    Stewart, S C; Rapnicki, P; Lewis, J R; Perala, M

    2007-09-01

    The ability of a commercially available panel reader system to read International Standards Organization-compliant electronic identification devices under commercial dairy conditions was examined. Full duplex (FDX-B) and half-duplex (HDX) low frequency radio-frequency identification external ear tags were utilized. The study involved 498 Holstein cows in the final 6 wk of gestation. There were 516 total electronic identification devices (n = 334 HDX and n = 182 FDX-B). Eighteen FDX-B were replaced with HDX during the study due to repeated detection failure. There were 6,679 HDX and 3,401 FDX-B device detection attempts. There were 220 (2.2%) unsuccessful and 9,860 (97.8%) successful identification detection attempts. There were 9 unsuccessful detection attempts for HDX (6,670/6,679 = 99.9% successful detection attempts) and 211 unsuccessful detection attempts for FDX-B (3,190/3,401 = 93.8% successful detection attempts). These results demonstrate that this panel system can achieve high detection rates of HDX devices and meet the needs of the most demanding management applications. The FDX-B detection rate was not sufficient for the most demanding applications, requiring a high degree of detection by panel readers. The lower FDX-B rate may not be inherent in the device technology itself, but could be due to other factors, including the particular panel reader utilized or the tuning of the panel reader.

  12. 50 CFR 260.7 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., memoranda, marks, other identifications, and devices for purposes of the Agricultural Marketing Act. 260.7..., marks, other identifications, and devices for purposes of the Agricultural Marketing Act. Subsection 203(h) of the Agricultural Marketing Act of 1946 provides criminal penalties for various specified...

  13. Investigating User Identification in Remote Patient Monitoring Devices.

    PubMed

    Ondiege, Brian; Clarke, Malcolm

    2017-09-13

    With the increase in the number of people having a chronic disease, there is an increase in households having more than a single person suffering from the same chronic illness. One problem of monitoring such patients in their own home is that current devices have a limitation in the number of people who can use a single device. This study investigates the use of Near Field Communication (NFC) for identification in a multi-user environment. A mixed-method qualitative and quantitative approach was adopted, including focus groups, observations and a field trial. Data were collected in three phases. In Phase 1, five focus groups were conducted with patients to determine their beliefs, concerns and issues with using identification in remote patient monitoring devices. In Phase 2, participants were given a blood pressure monitor modified to include an NFC reader to enable identification. The modified device was given to patients living as a couple in the same household and both suffering from hypertension. Both patients used the device for a period of two weeks to observe their acceptance of the technology and determine their experience of usage. A total of 40 (20 couples) patients participated in the trial. Non-adherence to the full monitoring regimen was low and was mainly due to usability issues or commitments taking them away from the home and thus unable to take readings. After the trial period participants were invited to discuss their experiences with the technology in a focus group discussion (Phase 3), a total of five focus groups were conducted. Focus group discussions with the patients revealed that most participants liked using the system and were not apprehensive towards Healthcare Information Technology (HIT). The participants also had suggestions for improvements that could be made to the modified blood pressure monitor (such as, rechargeable in place batteries, integrate the components, easier to use cuff, and increased sensitivity of the NFC reader) that

  14. Investigating User Identification in Remote Patient Monitoring Devices

    PubMed Central

    Clarke, Malcolm

    2017-01-01

    With the increase in the number of people having a chronic disease, there is an increase in households having more than a single person suffering from the same chronic illness. One problem of monitoring such patients in their own home is that current devices have a limitation in the number of people who can use a single device. This study investigates the use of Near Field Communication (NFC) for identification in a multi-user environment. Methods: A mixed-method qualitative and quantitative approach was adopted, including focus groups, observations and a field trial. Data were collected in three phases. In Phase 1, five focus groups were conducted with patients to determine their beliefs, concerns and issues with using identification in remote patient monitoring devices. In Phase 2, participants were given a blood pressure monitor modified to include an NFC reader to enable identification. The modified device was given to patients living as a couple in the same household and both suffering from hypertension. Both patients used the device for a period of two weeks to observe their acceptance of the technology and determine their experience of usage. A total of 40 (20 couples) patients participated in the trial. Non-adherence to the full monitoring regimen was low and was mainly due to usability issues or commitments taking them away from the home and thus unable to take readings. After the trial period participants were invited to discuss their experiences with the technology in a focus group discussion (Phase 3), a total of five focus groups were conducted. Focus group discussions with the patients revealed that most participants liked using the system and were not apprehensive towards Healthcare Information Technology (HIT). The participants also had suggestions for improvements that could be made to the modified blood pressure monitor (such as, rechargeable in place batteries, integrate the components, easier to use cuff, and increased sensitivity of the NFC

  15. MODAL TRACKING of A Structural Device: A Subspace Identification Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candy, J. V.; Franco, S. N.; Ruggiero, E. L.

    Mechanical devices operating in an environment contaminated by noise, uncertainties, and extraneous disturbances lead to low signal-to-noise-ratios creating an extremely challenging processing problem. To detect/classify a device subsystem from noisy data, it is necessary to identify unique signatures or particular features. An obvious feature would be resonant (modal) frequencies emitted during its normal operation. In this report, we discuss a model-based approach to incorporate these physical features into a dynamic structure that can be used for such an identification. The approach we take after pre-processing the raw vibration data and removing any extraneous disturbances is to obtain a representation ofmore » the structurally unknown device along with its subsystems that capture these salient features. One approach is to recognize that unique modal frequencies (sinusoidal lines) appear in the estimated power spectrum that are solely characteristic of the device under investigation. Therefore, the objective of this effort is based on constructing a black box model of the device that captures these physical features that can be exploited to “diagnose” whether or not the particular device subsystem (track/detect/classify) is operating normally from noisy vibrational data. Here we discuss the application of a modern system identification approach based on stochastic subspace realization techniques capable of both (1) identifying the underlying black-box structure thereby enabling the extraction of structural modes that can be used for analysis and modal tracking as well as (2) indicators of condition and possible changes from normal operation.« less

  16. Authentication of Radio Frequency Identification Devices Using Electronic Characteristics

    ERIC Educational Resources Information Center

    Chinnappa Gounder Periaswamy, Senthilkumar

    2010-01-01

    Radio frequency identification (RFID) tags are low-cost devices that are used to uniquely identify the objects to which they are attached. Due to the low cost and size that is driving the technology, a tag has limited computational capabilities and resources. This limitation makes the implementation of conventional security protocols to prevent…

  17. Implantation of radio frequency identification device (RFID) microchip in disaster victim identification (DVI).

    PubMed

    Meyer, Harald J; Chansue, Nantarika; Monticelli, Fabio

    2006-03-10

    The tsunami catastrophe of December 2004 left more than 200,000 dead. Disaster victim identification (DVI) teams were presented with the unprecedented challenge of identifying thousands of mostly markedly putrefied and partially skeletised bodies. To this end, an adequate body tagging method is essential. Conventional body bag tagging in terms of writing on body bags and placing of tags inside body bags proved unsatisfactory and problem prone due to consequences of cold storage, formalin (formaldehyde) embalming and body numbers inside storage facilities. The placement of radio frequency identification device (RFID) microchips inside victim bodies provided a practical solution to problems of body tagging and attribution in the DVI setting encountered by the Austrian DVI team in Thailand in early 2005.

  18. Event-recording devices with identification codes

    NASA Technical Reports Server (NTRS)

    Watters, David G. (Inventor); Huestis, David L. (Inventor); Bahr, Alfred J. (Inventor); Vidmar, Robert J. (Inventor)

    2003-01-01

    A recording device allows wireless interrogation to determine its identity and its state. The state indicates whether one or more physical or chemical events have taken place. In effect, the one or more physical or chemical events are recorded by the device. The identity of the device allows it to be distinguished from a number of similar devices. The recording device may be used in an array of devices that allows wireless probing by an interrogation unit. When probed, each device tells the interrogator who it is and what state it is in. The devices allow multiple use and the interrogator may use a logical reset to determine the state of each device. The interrogator can thus easily identify particular items in an array that have reached a particular condition. The device may record the status of each device in a database to maintain a history for each.

  19. Partial fingerprint identification algorithm based on the modified generalized Hough transform on mobile device

    NASA Astrophysics Data System (ADS)

    Qin, Jin; Tang, Siqi; Han, Congying; Guo, Tiande

    2018-04-01

    Partial fingerprint identification technology which is mainly used in device with small sensor area like cellphone, U disk and computer, has taken more attention in recent years with its unique advantages. However, owing to the lack of sufficient minutiae points, the conventional method do not perform well in the above situation. We propose a new fingerprint matching technique which utilizes ridges as features to deal with partial fingerprint images and combines the modified generalized Hough transform and scoring strategy based on machine learning. The algorithm can effectively meet the real-time and space-saving requirements of the resource constrained devices. Experiments on in-house database indicate that the proposed algorithm have an excellent performance.

  20. Identification of traffic control devices for mobile and short duration work operations

    DOT National Transportation Integrated Search

    2006-07-01

    This report documents and summarizes the study Identification of Traffic Control Devices for Mobile and Short Duration Work Operations, for the New Jersey Department of Transportation. The study was conducted in three tasks: 1. Literature Searc...

  1. 9 CFR 71.22 - Removal and loss of official identification devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Removal and loss of official identification devices. 71.22 Section 71.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  2. 9 CFR 71.22 - Removal and loss of official identification devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Removal and loss of official identification devices. 71.22 Section 71.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  3. 9 CFR 71.22 - Removal and loss of official identification devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Removal and loss of official identification devices. 71.22 Section 71.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  4. 9 CFR 71.22 - Removal and loss of official identification devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Removal and loss of official identification devices. 71.22 Section 71.22 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  5. Feature Selection and Classifier Development for Radio Frequency Device Identification

    DTIC Science & Technology

    2015-12-01

    adds important background knowledge for this research . 41 Four leading RF-based device identification methods have been proposed: Radio...appropriate level of dimensionality. Both qualitative and quantitative DRA dimensionality assessment methods are possible. Prior RF-DNA DRA research , e.g...Employing experimental designs to find optimal algorithm settings has been seen in hyperspectral anomaly detection research , c.f. [513–520], but not

  6. Wireless event-recording device with identification codes

    NASA Technical Reports Server (NTRS)

    Watters, David G. (Inventor); Huestis, David L. (Inventor); Bahr, Alfred J. (Inventor)

    2004-01-01

    A wireless recording device can be interrogated to determine its identity and its state. The state indicates whether a particular physical or chemical event has taken place. In effect, the physical or chemical event is recorded by the device. The identity of the device allows it to be distinguished from a number of similar devices. Thus the sensor device may be used in an array of devices that can be probed by a wireless interrogation unit. The device tells the interrogator who it is and what state it is in. The interrogator can thus easily identify particular items in an array that have reached a particular condition.

  7. Blind source computer device identification from recorded VoIP calls for forensic investigation.

    PubMed

    Jahanirad, Mehdi; Anuar, Nor Badrul; Wahab, Ainuddin Wahid Abdul

    2017-03-01

    The VoIP services provide fertile ground for criminal activity, thus identifying the transmitting computer devices from recorded VoIP call may help the forensic investigator to reveal useful information. It also proves the authenticity of the call recording submitted to the court as evidence. This paper extended the previous study on the use of recorded VoIP call for blind source computer device identification. Although initial results were promising but theoretical reasoning for this is yet to be found. The study suggested computing entropy of mel-frequency cepstrum coefficients (entropy-MFCC) from near-silent segments as an intrinsic feature set that captures the device response function due to the tolerances in the electronic components of individual computer devices. By applying the supervised learning techniques of naïve Bayesian, linear logistic regression, neural networks and support vector machines to the entropy-MFCC features, state-of-the-art identification accuracy of near 99.9% has been achieved on different sets of computer devices for both call recording and microphone recording scenarios. Furthermore, unsupervised learning techniques, including simple k-means, expectation-maximization and density-based spatial clustering of applications with noise (DBSCAN) provided promising results for call recording dataset by assigning the majority of instances to their correct clusters. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  8. Load power device, system and method of load control and management employing load identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  9. A neural network device for on-line particle identification in cosmic ray experiments

    NASA Astrophysics Data System (ADS)

    Scrimaglio, R.; Finetti, N.; D'Altorio, L.; Rantucci, E.; Raso, M.; Segreto, E.; Tassoni, A.; Cardarilli, G. C.

    2004-05-01

    On-line particle identification is one of the main goals of many experiments in space both for rare event studies and for optimizing measurements along the orbital trajectory. Neural networks can be a useful tool for signal processing and real time data analysis in such experiments. In this document we report on the performances of a programmable neural device which was developed in VLSI analog/digital technology. Neurons and synapses were accomplished by making use of Operational Transconductance Amplifier (OTA) structures. In this paper we report on the results of measurements performed in order to verify the agreement of the characteristic curves of each elementary cell with simulations and on the device performances obtained by implementing simple neural structures on the VLSI chip. A feed-forward neural network (Multi-Layer Perceptron, MLP) was implemented on the VLSI chip and trained to identify particles by processing the signals of two-dimensional position-sensitive Si detectors. The radiation monitoring device consisted of three double-sided silicon strip detectors. From the analysis of a set of simulated data it was found that the MLP implemented on the neural device gave results comparable with those obtained with the standard method of analysis confirming that the implemented neural network could be employed for real time particle identification.

  10. An investigation into the feasibility of locating portable medical devices using radio frequency identification devices and technology.

    PubMed

    Britton, J

    2007-01-01

    Portable medical devices represent an important resource for assisting healthcare delivery. The movement of portable devices often results in them being unavailable when needed. Tracking equipment using radiofrequency identification technology/devices (RFID) may provide a promising solution to the problems encountered in locating portable equipment. An RFID technology trial was undertaken at Royal Alexandra Hospital, Paisley. This involved the temporary installation of three active readers and attaching actively transmitting radio frequency tags to different portable medical devices. The active readers and computer system were linked using a bespoke data network. Tags and readers from two separate manufacturers were tested. Reliability difficulties were encountered when testing the technology from the first manufacturer, probably due to the casing of the medical device interfering with the signal from the tag. Improved results were obtained when using equipment from the second manufacturer with an overall error rate of 12.3%. Tags from this manufacturer were specifically designed to overcome problems observed with the first system tested. Findings from this proof of concept trial suggest that RFID technology could be used to track the location of equipment in a hospital.

  11. 77 FR 57055 - Agency Information Collection Activities; Proposed Collection; Unique Device Identification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Parts 16, 801, 803, 806, 810, 814, 820, 821, 822, and 830 [Docket No. FDA-2011-N-0090] RIN 0910-AG31 Agency Information Collection Activities; Proposed Collection; Unique Device Identification System; Extension of Comment Period...

  12. Approach for the Development of a Framework for the Identification of Activities of Daily Living Using Sensors in Mobile Devices.

    PubMed

    Pires, Ivan Miguel; Garcia, Nuno M; Pombo, Nuno; Flórez-Revuelta, Francisco; Spinsante, Susanna

    2018-02-21

    Sensors available on mobile devices allow the automatic identification of Activities of Daily Living (ADL). This paper describes an approach for the creation of a framework for the identification of ADL, taking into account several concepts, including data acquisition, data processing, data fusion, and pattern recognition. These concepts can be mapped onto different modules of the framework. The proposed framework should perform the identification of ADL without Internet connection, performing these tasks locally on the mobile device, taking in account the hardware and software limitations of these devices. The main purpose of this paper is to present a new approach for the creation of a framework for the recognition of ADL, analyzing the allowed sensors available in the mobile devices, and the existing methods available in the literature.

  13. Approach for the Development of a Framework for the Identification of Activities of Daily Living Using Sensors in Mobile Devices

    PubMed Central

    Pombo, Nuno

    2018-01-01

    Sensors available on mobile devices allow the automatic identification of Activities of Daily Living (ADL). This paper describes an approach for the creation of a framework for the identification of ADL, taking into account several concepts, including data acquisition, data processing, data fusion, and pattern recognition. These concepts can be mapped onto different modules of the framework. The proposed framework should perform the identification of ADL without Internet connection, performing these tasks locally on the mobile device, taking in account the hardware and software limitations of these devices. The main purpose of this paper is to present a new approach for the creation of a framework for the recognition of ADL, analyzing the allowed sensors available in the mobile devices, and the existing methods available in the literature. PMID:29466316

  14. Effects of low speed wind on the recognition/identification and pass-through communication tasks of auditory situation awareness afforded by military hearing protection/enhancement devices and tactical communication and protective systems.

    PubMed

    Lee, Kichol; Casali, John G

    2016-01-01

    To investigate the effect of controlled low-speed wind-noise on the auditory situation awareness performance afforded by military hearing protection/enhancement devices (HPED) and tactical communication and protective systems (TCAPS). Recognition/identification and pass-through communications tasks were separately conducted under three wind conditions (0, 5, and 10 mph). Subjects wore two in-ear-type TCAPS, one earmuff-type TCAPS, a Combat Arms Earplug in its 'open' or pass-through setting, and an EB-15LE electronic earplug. Devices with electronic gain systems were tested under two gain settings: 'unity' and 'max'. Testing without any device (open ear) was conducted as a control. Ten subjects were recruited from the student population at Virginia Tech. Audiometric requirements were 25 dBHL or better at 500, 1000, 2000, 4000, and 8000 Hz in both ears. Performance on the interaction of communication task-by-device was significantly different only in 0 mph wind speed. The between-device performance differences varied with azimuthal speaker locations. It is evident from this study that stable (non-gusting) wind speeds up to 10 mph did not significantly degrade recognition/identification task performance and pass-through communication performance of the group of HPEDs and TCAPS tested. However, the various devices performed differently as the test sound signal speaker location was varied and it appears that physical as well as electronic features may have contributed to this directional result.

  15. Prevention, identification, and management of post-operative penile implant complications of infection, hematoma, and device malfunction

    PubMed Central

    O’Rourke, Timothy K.; Erbella, Alexander; Zhang, Yu

    2017-01-01

    Penile prosthesis implant surgery is an effective management approach for a number of urological conditions, including medication refractory erectile dysfunction (ED). Complications encountered post-operatively include infection, bleeding/hematoma, and device malfunction. Since the 1970s, modifications to these devices have reduced complication rates through improvement in antisepsis and design using antibiotic coatings, kink-resistant tubing, lock-out valves to prevent autoinflation, and modified reservoir shapes. Device survival and complication rates have been investigated predominately by retrospective database-derived studies. This review article focuses on the identification and management of post-operative complications following penile prosthetic and implant surgery. Etiology for ED, surgical technique, and prosthesis type are variable among studies. The most common post-operative complications of infection, bleeding, and device malfunction may be minimized by adherence to consistent technique and standard protocol. Novel antibiotic coatings and standard antibiotic regimen may reduce infection rates. Meticulous hemostasis and intraoperative testing of devices may further reduce need for revision surgery. Additional prospective studies with consistent reporting of outcomes and comparison of surgical approach and prosthesis type in patients with variable ED etiology would be beneficial. PMID:29238663

  16. Note: Model-based identification method of a cable-driven wearable device for arm rehabilitation

    NASA Astrophysics Data System (ADS)

    Cui, Xiang; Chen, Weihai; Zhang, Jianbin; Wang, Jianhua

    2015-09-01

    Cable-driven exoskeletons have used active cables to actuate the system and are worn on subjects to provide motion assistance. However, this kind of wearable devices usually contains uncertain kinematic parameters. In this paper, a model-based identification method has been proposed for a cable-driven arm exoskeleton to estimate its uncertainties. The identification method is based on the linearized error model derived from the kinematics of the exoskeleton. Experiment has been conducted to demonstrate the feasibility of the proposed model-based method in practical application.

  17. Total-dose radiation effects data for semiconductor devices, volume 1. [radiation resistance of components for the Galileo Project

    NASA Technical Reports Server (NTRS)

    Price, W. E.; Martin, K. E.; Nichols, D. K.; Gauthier, M. K.; Brown, S. F.

    1981-01-01

    Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. Data are presented by JPL for various NASA space programs on diodes, bipolar transistors, field effect transistors, silicon-controlled rectifiers, and optical devices. A vendor identification code list is included along with semiconductor device electrical parameter symbols and abbreviations.

  18. 7 CFR 28.176 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., other identifications, and devices for purpose of the Agricultural Marketing Act. 28.176 Section 28.176 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER...

  19. 7 CFR 52.3 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., other identifications, and devices for purposes of the Agricultural Marketing Act. 52.3 Section 52.3 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...

  20. 7 CFR 51.3 - Designation of official certificates, memoranda, marks, other identifications and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., other identifications and devices for purposes of the Agricultural Marketing Act. 51.3 Section 51.3 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL...

  1. Paramedic electrocardiogram and rhythm identification: a convenient training device.

    PubMed

    Hale, Peggy; Lowe, Robert; Seamon, Jason P; Jenkins, James J

    2011-10-01

    A common reason for utilizing local paramedics and the emergency medical services is for the recognition and immediate treatment of chest pain, a complaint that has multiple possible etiologies. While many of those complaining of disease processes responsible for chest pain are benign, some will be life-threatening and will require immediate identification and treatment. The ability of paramedics to not only perform field electrocardiograms (ECGs), but to accurately diagnose various unstable cardiac rhythms has shown significant reduction in time to specific treatments. Increasing the overall accuracy of ECG interpretation by paramedics has the potential to facilitate early and appropriate treatment and decrease patient morbidity and mortality. A convenient training device (flip book) on ambulances and in common areas in the fire station could improve field interpretation of certain cardiac rhythms. This training device consists of illustrated sample ECG tracings and their associated diagnostic criteria. The goal was to enhance the recognition and interpretation of ECGs, and thereby, reduce delays in the initiation of treatment and potential complications associated with misinterpretation.This study was a prospective, observational study using a matched pre-test/post-test design. The study period was from November 2008 to December 2008. A total of 136 paramedics were approached to participate in this study. A pre-test consisting of 15 12-lead ECGs was given to all paramedics who agreed to participate in the study. Once the pre-tests were completed, the flip books were placed in common areas. Approximately one month after the flip books were made available to the paramedics, a post-test was administered.Statistical comparisons were made between the pre- and post-test scores for both the global test and each type of rhythm. Using these data, there were no statistically significant improvements in the global ECG interpretation or on individual rhythm interpretations

  2. 7 CFR 70.2 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., other identifications, and devices for purposes of the Agricultural Marketing Act. 70.2 Section 70.2 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE...

  3. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorman, A; Seabrook, G; Brakken, A

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6.more » They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.« less

  4. 7 CFR 58.2 - Designation of official certificates, memoranda, marks, identifications, and devices for purpose...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Designation of official certificates, memoranda, marks, identifications, and devices for purpose of the Agricultural Marketing Act. 58.2 Section 58.2 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices),...

  5. 7 CFR 56.2 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Designation of official certificates, memoranda, marks, other identifications, and devices for purposes of the Agricultural Marketing Act. 56.2 Section 56.2 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices),...

  6. 9 CFR 592.5 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Designation of official certificates, memoranda, marks, other identifications, and devices for purposes of the Agricultural Marketing Act. 592.5 Section 592.5 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY...

  7. 9 CFR 592.5 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Designation of official certificates, memoranda, marks, other identifications, and devices for purposes of the Agricultural Marketing Act. 592.5 Section 592.5 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY...

  8. 9 CFR 592.5 - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Designation of official certificates, memoranda, marks, other identifications, and devices for purposes of the Agricultural Marketing Act. 592.5 Section 592.5 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EGG PRODUCTS INSPECTION VOLUNTARY...

  9. Device-identified atrial fibrillation at pacing clinics. Should it guide anticoagulation?

    PubMed

    Merinopoulos, Ioannis; Raphael, Claire E; Yardley, Alaina; Goonewardene, Manoj; Vassiliou, Vassilios S

    2016-03-15

    In recent years, there has been a significant increase in the number of devices implanted following improvement in their safety profile, extension of indications and reduction in cost. Although the reason remains largely the beneficial effect on heart rhythm stabilisation, implanted devices might also have additional advantages, notably identification of silent arrhythmia. Should clinicians therefore act on device-identified atrial fibrillation (AF) and should such identification be used to guide anticoagulation management? This review evaluates the current evidence on the management of device-identified asymptomatic AF. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Load power device and system for real-time execution of hierarchical load identification algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yi; Madane, Mayura Arun; Zambare, Prachi Suresh

    A load power device includes a power input; at least one power output for at least one load; and a plurality of sensors structured to sense voltage and current at the at least one power output. A processor is structured to provide real-time execution of: (a) a plurality of load identification algorithms, and (b) event detection and operating mode detection for the at least one load.

  11. Automatic cell identification and visualization using digital holographic microscopy with head mounted augmented reality devices.

    PubMed

    O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram

    2018-03-01

    We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.

  12. 7 CFR 61.2a - Designation of official certificates, memoranda, marks, other identifications, and devices for...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Designation of official certificates, memoranda, marks, other identifications, and devices for purpose of the Agricultural Marketing Act. 61.2a Section 61.2a Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices)...

  13. Portable data collection device

    DOEpatents

    French, P.D.

    1996-06-11

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time. 7 figs.

  14. Portable data collection device

    DOEpatents

    French, Patrick D.

    1996-01-01

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of a time.

  15. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  16. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  17. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  18. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  19. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  20. System Identification of a Heaving Point Absorber: Design of Experiment and Device Modeling

    DOE PAGES

    Bacelli, Giorgio; Coe, Ryan; Patterson, David; ...

    2017-04-01

    Empirically based modeling is an essential aspect of design for a wave energy converter. These models are used in structural, mechanical and control design processes, as well as for performance prediction. The design of experiments and methods used to produce models from collected data have a strong impact on the quality of the model. This study considers the system identification and model validation process based on data collected from a wave tank test of a model-scale wave energy converter. Experimental design and data processing techniques based on general system identification procedures are discussed and compared with the practices often followedmore » for wave tank testing. The general system identification processes are shown to have a number of advantages. The experimental data is then used to produce multiple models for the dynamics of the device. These models are validated and their performance is compared against one and other. Furthermore, while most models of wave energy converters use a formulation with wave elevation as an input, this study shows that a model using a hull pressure sensor to incorporate the wave excitation phenomenon has better accuracy.« less

  1. System Identification of a Heaving Point Absorber: Design of Experiment and Device Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacelli, Giorgio; Coe, Ryan; Patterson, David

    Empirically based modeling is an essential aspect of design for a wave energy converter. These models are used in structural, mechanical and control design processes, as well as for performance prediction. The design of experiments and methods used to produce models from collected data have a strong impact on the quality of the model. This study considers the system identification and model validation process based on data collected from a wave tank test of a model-scale wave energy converter. Experimental design and data processing techniques based on general system identification procedures are discussed and compared with the practices often followedmore » for wave tank testing. The general system identification processes are shown to have a number of advantages. The experimental data is then used to produce multiple models for the dynamics of the device. These models are validated and their performance is compared against one and other. Furthermore, while most models of wave energy converters use a formulation with wave elevation as an input, this study shows that a model using a hull pressure sensor to incorporate the wave excitation phenomenon has better accuracy.« less

  2. 33 CFR 159.55 - Identification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.55 Identification. (a) Each... without loss of legibility the combined effects of normal wear and tear and exposure to water, salt spray...

  3. System-on-fluidics immunoassay device integrating wireless radio-frequency-identification sensor chips.

    PubMed

    Yazawa, Yoshiaki; Oonishi, Tadashi; Watanabe, Kazuki; Shiratori, Akiko; Funaoka, Sohei; Fukushima, Masao

    2014-09-01

    A simple and sensitive point-of-care-test (POCT) device for chemiluminescence (CL) immunoassay was devised and tested. The device consists of a plastic flow-channel reactor and two wireless-communication sensor chips, namely, a photo-sensor chip and a temperature-sensor chip. In the flow-channel reactor, a target antigen is captured by an antibody immobilized on the inner wall of the flow-channel and detected with enzyme labeled antibody by using CL substrate. The CL signal corresponding to the amount of antigen is measured by a newly developed radio-frequency-identification (RFID) sensor, which enables batteryless operation and wireless data communication with an external reader. As for the POCT device, its usage environment, especially temperature, varies for each measurement. Hence, temperature compensation is a key issue in regard to eliminating dark-signal fluctuation, which is a major factor in deterioration of the precision of the POCT device. A two-stage temperature-compensation scheme was adopted. As for the first stage, the signals of two photodiodes, one with an open window and one with a sealed window, integrated on the photo-sensor chip are differentiated to delete the dark signal. As for the second stage, the differentiated signal fluctuation caused by a temperature variation is compensated by using the other sensor chip (equipped with a temperature sensor). The dark-level fluctuation caused by temperature was reduced from 0.24 to 0.02 pA/°C. The POCT device was evaluated as a CL immunoassay of thyroid-stimulating hormone (TSH). The flow rate of the CL reagent in the flow channel was optimized. As a result, the detection limit of the POCT device was 0.08 ng/ml (i.e., 0.4 μIU/ml). Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  4. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    PubMed

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  5. Feasibility results of an electromagnetic compatibility test protocol to evaluate medical devices to radio frequency identification exposure.

    PubMed

    Seidman, Seth J; Bekdash, Omar; Guag, Joshua; Mehryar, Maryam; Booth, Paul; Frisch, Paul

    2014-08-03

    The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID.

  6. Wireless device monitoring systems and monitoring devices, and associated methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCown, Steven H; Derr, Kurt W; Rohde, Kenneth W

    Wireless device monitoring systems and monitoring devices include a communications module for receiving wireless communications of a wireless device. Processing circuitry is coupled with the communications module and configured to process the wireless communications to determine whether the wireless device is authorized or unauthorized to be present at the monitored area based on identification information of the wireless device. Methods of monitoring for the presence and identity of wireless devices are also provided.

  7. Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification

    PubMed Central

    2013-01-01

    Background The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Methods Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125–134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. Results For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Conclusion Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to

  8. Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification.

    PubMed

    Seidman, Seth J; Guag, Joshua W

    2013-07-11

    The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125-134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior

  9. Feasibility results of an electromagnetic compatibility test protocol to evaluate medical devices to radio frequency identification exposure

    PubMed Central

    2014-01-01

    Background The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. Methods This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. Results The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. Conclusions This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID. PMID:25086451

  10. Radiofrequency-Based Identification Medical Device: An Evaluable Solution for Surgical Sponge Retrieval?

    PubMed

    Lazzaro, Alessandra; Corona, Arianna; Iezzi, Luca; Quaresima, Silvia; Armisi, Luca; Piccolo, Ilaria; Medaglia, Carlo Maria; Sbrenni, Sergio; Sileri, Pierpaolo; Rosato, Nicola; Gaspari, Achille Lucio; Di Lorenzo, Nicola

    2017-06-01

    A retained surgical item in patients (gossypiboma) is a persisting problem, despite consistent improvements and existing guidelines in counting instruments and sponges. Previous experiences with radiofrequency identification technology (RFID) tracking sponges show that it could represent an innovation, in order to reduce the criticism and increase the effectiveness during surgical procedures. We present an automated system that allows reduction of errors and improves safety in the operating room. The system consists of 3 antennas, surgical sponges containing RFID tags, and dedicated software applications, with Wi-Fi real-time communication between devices. The first antenna provides the initial count of gauzes; the second a real-time counting during surgery, including the sponges thrown into the kick-bucket; and the third can be used in the event of uneven sponge count. The software allows management at all stages of the process. In vitro and in vivo tests were performed: the system provided excellent results in detecting sponges in patients' body. Hundred percent retained sponges were detected correctly, even when they were overlapped. No false positive or false negative was recorded. The counting procedure turned out to be more streamlined and efficient and it could save time in a standard procedure. The RFID system for sponge tracking was shown to be experimentally a reliable and feasible method to track sponges with a full detection accuracy in the operating room. The results indicate the system to be safe and effective with acceptable cost-effective parameters.

  11. Color identification testing device

    NASA Technical Reports Server (NTRS)

    Brawner, E. L.; Martin, R.; Pate, W.

    1970-01-01

    Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

  12. Medical Device Guidebook: A browser information resource for medical device users.

    PubMed

    Clarkson, Douglas M

    2017-03-01

    A web based information resource - the 'Medical Device Guidebook' - for the enabling of safe use of medical devices is described. Medical devices are described within a 'catalogue' of specific models and information on a specific model is provided within a consistent set of information 'keys'. These include 'user manuals', 'points of caution', 'clinical use framework', 'training/assessment material', 'frequently asked questions', 'authorised user comments' and 'consumables'. The system allows identification of known risk/hazards associated with specific devices, triggered, for example, by national alerts or locally raised safety observations. This provides a mechanism for more effective briefing of equipment users on the associated hazards of equipment. A feature of the system is the inclusion of a specific 'Operational Procedure' for each device, where the lack of this focus is shown in the literature to often be a key factor in equipment misuse and associated patient injury. The 'Guidebook' provides a mechanism for the development of an information resource developed within local clinical networks and encourages a consistent approach to medical device use. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Canine human scent identifications with post-blast debris collected from improvised explosive devices.

    PubMed

    Curran, Allison M; Prada, Paola A; Furton, Kenneth G

    2010-06-15

    In this study it is demonstrated that human odor collected from items recovered at a post-blast scene can be evaluated using human scent specific canine teams to locate and identify individuals who have been in contact with the improvised explosive device (IED) components and/or the delivery vehicle. The purpose of the experiments presented here was to document human scent survivability in both peroxide-based explosions as well as simulated roadside IEDs utilizing double-blind field trials. Human odor was collected from post-blast device and vehicle components. Human scent specific canine teams were then deployed at the blast scene and in locations removed from the blast scene to validate that human odor remains in sufficient quantities for reliable canine detection and identification. Human scent specific canines have shown the ability to identify individuals who have been in contact with IEDs using post-blast debris with an average success from site response of 82.2% verifying that this technology has great potential in criminal, investigative, and military applications. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Gastroenterology-urology devices; reclassification of implanted blood access devices. Final rule.

    PubMed

    2014-07-25

    The Food and Drug Administration (FDA) is issuing a final order to reclassify implanted blood access devices, a preamendments class III device, into class II (special controls) based on new information and subject to premarket notification and to further clarify the identification.

  15. Stimulus probability effects in absolute identification.

    PubMed

    Kent, Christopher; Lamberts, Koen

    2016-05-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of presentation probability on both proportion correct and response times. The effects were moderated by the ubiquitous stimulus position effect. The accuracy and response time data were predicted by an exemplar-based model of perceptual cognition (Kent & Lamberts, 2005). The bow in discriminability was also attenuated when presentation probability for middle items was relatively high, an effect that will constrain future model development. The study provides evidence for item-specific learning in absolute identification. Implications for other theories of absolute identification are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. Bayesian Modeling for Identification and Estimation of the Learning Effects of Pointing Tasks

    NASA Astrophysics Data System (ADS)

    Kyo, Koki

    Recently, in the field of human-computer interaction, a model containing the systematic factor and human factor has been proposed to evaluate the performance of the input devices of a computer. This is called the SH-model. In this paper, in order to extend the range of application of the SH-model, we propose some new models based on the Box-Cox transformation and apply a Bayesian modeling method for identification and estimation of the learning effects of pointing tasks. We consider the parameters describing the learning effect as random variables and introduce smoothness priors for them. Illustrative results show that the newly-proposed models work well.

  17. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  18. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  19. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  20. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  1. 21 CFR 872.2050 - Dental sonography device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...

  2. Interference with the operation of medical devices resulting from the use of radio frequency identification technology.

    PubMed

    Houliston, Bryan; Parry, David; Webster, Craig S; Merry, Alan F

    2009-06-19

    To replicate electromagnetic interference (EMI) with a common drug infusion device resulting from the use of radio frequency identification (RFID) technology in a simulated operating theatre environment. An infusion pump, of a type previously reported as having failed due to RFID EMI, was placed in radio frequency (RF) fields of various strengths, and its operation observed. Different strength RF fields were created by varying the number of RFID readers, the use of a high-gain RFID antenna, the distance between the reader(s) and the infusion pump, and the presence of an RFID tag on the infusion pump. The infusion pump was not affected by low-power RFID readers, even when in direct contact. The pump was disrupted by a high-power reader at 10 cm distance when an RFID tag was attached, and by a combination of high-power and low-power readers at 10 cm distance. Electronic medical devices may fail in the presence of high-power RFID readers, especially if the device is tagged. However, low-power RFID readers appear to be safer.

  3. Noise Source Identification and Dynamic Modeling of a Pneumatic Nailing Device =

    NASA Astrophysics Data System (ADS)

    Nili Ahmadabadi, Zahra

    Exposure to hazardous noise levels emitted by pneumatic nailing devices contributes significantly to risk of hearing damage among the construction workers throughout the world. This health problem comes from the lack of appropriate technology such as low noise devices which in turn results from the lack of scientific knowledge about designing reduced noise devices. This study contributes to the design improvement of pneumatic nailing devices through identifying the noise sources and developing the simulation tool required to redesign the pneumatic nailing device. To identify the noise sources, the study uses a combination of two complementary experimental approaches. The first makes use of time-synchronized data analysis of several variables during the machine operation. This strategy allows identifying the physical processes and provides a detailed separation of the noise generation mechanisms in successive time sequences. However, since multiple noise sources radiate at the same time, this observation approach is not sufficient for noise source identification and ranking. Thus, it is completed by a selective wrapping and muffler procedure. This technique provides overall generated noise associated with each process, as well as ranking of the three major sources: (1) exhaust noise, (2) machine body vibrations, and (3) workpiece vibrations. A special investigation is conducted on this third one with two cases: a workpiece/worktable setup representative of the actual field usage of a nailing device and a workpiece/sandbox setup used in a standardized laboratory test. The study evaluates the efficiency of the workpiece/sandbox setup in reducing the workpiece radiation and obtains a typical workpiece contribution on an actual worksite. To provide a simulation tool, a dynamic model of the pneumatic nailing device needs to be developed. Dynamic modeling of the nailing device requires mathematical modeling of the physical processes involved in its operation. All of these

  4. Improving substructure identification accuracy of shear structures using virtual control system

    NASA Astrophysics Data System (ADS)

    Zhang, Dongyu; Yang, Yang; Wang, Tingqiang; Li, Hui

    2018-02-01

    Substructure identification is a powerful tool to identify the parameters of a complex structure. Previously, the authors developed an inductive substructure identification method for shear structures. The identification error analysis showed that the identification accuracy of this method is significantly influenced by the magnitudes of two key structural responses near a certain frequency; if these responses are unfavorable, the method cannot provide accurate estimation results. In this paper, a novel method is proposed to improve the substructure identification accuracy by introducing a virtual control system (VCS) into the structure. A virtual control system is a self-balanced system, which consists of some control devices and a set of self-balanced forces. The self-balanced forces counterbalance the forces that the control devices apply on the structure. The control devices are combined with the structure to form a controlled structure used to replace the original structure in the substructure identification; and the self-balance forces are treated as known external excitations to the controlled structure. By optimally tuning the VCS’s parameters, the dynamic characteristics of the controlled structure can be changed such that the original structural responses become more favorable for the substructure identification and, thus, the identification accuracy is improved. A numerical example of 6-story shear structure is utilized to verify the effectiveness of the VCS based controlled substructure identification method. Finally, shake table tests are conducted on a 3-story structural model to verify the efficacy of the VCS to enhance the identification accuracy of the structural parameters.

  5. 21 CFR 872.1740 - Caries detection device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Caries detection device. 872.1740 Section 872.1740...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification. The caries detection device is a device intended to show the existence of decay in a patient's tooth...

  6. Investigations of quantum effect semiconductor devices: The tunnel switch diode and the velocity modulation transistor

    NASA Astrophysics Data System (ADS)

    Daniel, Erik Stephen

    In this thesis we present the results of experimental and theoretical studies of two quantum effect devices--the Tunnel Switch Diode (TSD) and the Velocity Modulation Transistor (VMT). We show that TSD devices can be fabricated such that they behave (semi-quantitatively) as predicted by simple analytical models and more advanced drift-diffusion simulations. These devices possess characteristics, such as on-state currents which range over nearly five orders of magnitude, and on/off current ratios which are even larger, which may allow for a practical implementation of a very dense transistorless SRAM architecture and possibly other novel circuit designs. We demonstrate that many TSD properties can be explained by analogy to a thyristor. In particular, we show that the thin oxide layer in the TSD plays a critical role, and that this can be understood in terms of current injection through the oxide, analogous to transport through the "current limiting" layer in a thyristor. As this oxide layer can be subjected to extreme stress during device operation, we have studied the effect of this stress on device behavior. We demonstrate many significant stress-dependent effects, and identify structures and operation modes which minimize these effects. We propose an InAs/GaSb/AlSb VMT which may allow for larger conductance modulation and higher temperature operation than has been demonstrated in similar GaAs/AlAs structures. Fundamental differences in device operation in the two materials systems and unusual transport mechanisms in the InAs/GaSb/AlSb system are identified as a result of the band lineups in the two systems. Boltzmann transport simulations are developed and presented, allowing a qualitative description of the transport in the InAs/GaSb/AlSb structure. Band structure calculations are carried out, allowing for device design. While no working VMT devices were produced, this is believed to be due to processing and crystal growth problems. We present methods used to

  7. Electrostatic melting in a single-molecule field-effect transistor with applications in genomic identification

    PubMed Central

    Vernick, Sefi; Trocchia, Scott M.; Warren, Steven B.; Young, Erik F.; Bouilly, Delphine; Gonzalez, Ruben L.; Nuckolls, Colin; Shepard, Kenneth L.

    2017-01-01

    The study of biomolecular interactions at the single-molecule level holds great potential for both basic science and biotechnology applications. Single-molecule studies often rely on fluorescence-based reporting, with signal levels limited by photon emission from single optical reporters. The point-functionalized carbon nanotube transistor, known as the single-molecule field-effect transistor, is a bioelectronics alternative based on intrinsic molecular charge that offers significantly higher signal levels for detection. Such devices are effective for characterizing DNA hybridization kinetics and thermodynamics and enabling emerging applications in genomic identification. In this work, we show that hybridization kinetics can be directly controlled by electrostatic bias applied between the device and the surrounding electrolyte. We perform the first single-molecule experiments demonstrating the use of electrostatics to control molecular binding. Using bias as a proxy for temperature, we demonstrate the feasibility of detecting various concentrations of 20-nt target sequences from the Ebolavirus nucleoprotein gene in a constant-temperature environment. PMID:28516911

  8. 21 CFR 882.1560 - Skin potential measurement device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...

  9. 21 CFR 882.1560 - Skin potential measurement device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...

  10. 21 CFR 882.1560 - Skin potential measurement device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...

  11. 21 CFR 882.1560 - Skin potential measurement device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...

  12. A reference estimator based on composite sensor pattern noise for source device identification

    NASA Astrophysics Data System (ADS)

    Li, Ruizhe; Li, Chang-Tsun; Guan, Yu

    2014-02-01

    It has been proved that Sensor Pattern Noise (SPN) can serve as an imaging device fingerprint for source camera identification. Reference SPN estimation is a very important procedure within the framework of this application. Most previous works built reference SPN by averaging the SPNs extracted from 50 images of blue sky. However, this method can be problematic. Firstly, in practice we may face the problem of source camera identification in the absence of the imaging cameras and reference SPNs, which means only natural images with scene details are available for reference SPN estimation rather than blue sky images. It is challenging because the reference SPN can be severely contaminated by image content. Secondly, the number of available reference images sometimes is too few for existing methods to estimate a reliable reference SPN. In fact, existing methods lack consideration of the number of available reference images as they were designed for the datasets with abundant images to estimate the reference SPN. In order to deal with the aforementioned problem, in this work, a novel reference estimator is proposed. Experimental results show that our proposed method achieves better performance than the methods based on the averaged reference SPN, especially when few reference images used.

  13. 21 CFR 872.1870 - Sulfide detection device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sulfide detection device. 872.1870 Section 872.1870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1870 Sulfide detection device. (a) Identification...

  14. 21 CFR 872.1740 - Caries detection device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Caries detection device. 872.1740 Section 872.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification...

  15. 21 CFR 872.1740 - Caries detection device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Caries detection device. 872.1740 Section 872.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification...

  16. Electromagnetic interference of cardiac rhythmic monitoring devices to radio frequency identification: analytical analysis and mitigation methodology.

    PubMed

    Ogirala, Ajay; Stachel, Joshua R; Mickle, Marlin H

    2011-11-01

    Increasing density of wireless communication and development of radio frequency identification (RFID) technology in particular have increased the susceptibility of patients equipped with cardiac rhythmic monitoring devices (CRMD) to environmental electro magnetic interference (EMI). Several organizations reported observing CRMD EMI from different sources. This paper focuses on mathematically analyzing the energy as perceived by the implanted device, i.e., voltage. Radio frequency (RF) energy transmitted by RFID interrogators is considered as an example. A simplified front-end equivalent circuit of a CRMD sensing circuitry is proposed for the analysis following extensive black-box testing of several commercial pacemakers and implantable defibrillators. After careful understanding of the mechanics of the CRMD signal processing in identifying the QRS complex of the heart-beat, a mitigation technique is proposed. The mitigation methodology introduced in this paper is logical in approach, simple to implement and is therefore applicable to all wireless communication protocols.

  17. 21 CFR 892.2020 - Medical image communications device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...

  18. 21 CFR 892.2020 - Medical image communications device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...

  19. 21 CFR 892.2020 - Medical image communications device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...

  20. 21 CFR 892.2020 - Medical image communications device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...

  1. 21 CFR 892.2010 - Medical image storage device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...

  2. 21 CFR 892.2010 - Medical image storage device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...

  3. 21 CFR 892.2010 - Medical image storage device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...

  4. 21 CFR 892.2010 - Medical image storage device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...

  5. 21 CFR 886.1450 - Corneal radius measuring device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal radius measuring device. 886.1450 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1450 Corneal radius measuring device. (a) Identification. A corneal radius measuring device is an AC-powered device intended to measure...

  6. 21 CFR 886.4360 - Ocular surgery irrigation device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...

  7. 21 CFR 886.4360 - Ocular surgery irrigation device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...

  8. 21 CFR 886.4360 - Ocular surgery irrigation device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...

  9. 21 CFR 886.4360 - Ocular surgery irrigation device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...

  10. 21 CFR 886.4360 - Ocular surgery irrigation device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...

  11. 21 CFR 892.2010 - Medical image storage device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...

  12. 78 FR 58785 - Unique Device Identification System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ... to submitting a report. It will allow FDA, health care providers, and industry to more rapidly...-sustaining. Under the UDI system established by this rule, the health care community and the public will be... with any similar device which might lead to misuse of the device. Health care providers will no longer...

  13. 21 CFR 820.60 - Identification.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Identification. 820.60 Section 820.60 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES QUALITY SYSTEM REGULATION Identification and Traceability § 820.60 Identification. Each manufacturer shall...

  14. 21 CFR 892.1670 - Spot-film device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...

  15. 21 CFR 892.1670 - Spot-film device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...

  16. 21 CFR 892.1670 - Spot-film device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...

  17. 21 CFR 892.1670 - Spot-film device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...

  18. 21 CFR 892.1670 - Spot-film device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...

  19. Portable data collection device with self identifying probe

    DOEpatents

    French, P.D.

    1998-11-17

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of time. The sensor may also store a unique sensor identifier. 13 figs.

  20. Portable data collection device with self identifying probe

    DOEpatents

    French, Patrick D.

    1998-01-01

    The present invention provides a portable data collection device that has a variety of sensors that are interchangeable with a variety of input ports in the device. The various sensors include a data identification feature that provides information to the device regarding the type of physical data produced by each sensor and therefore the type of sensor itself. The data identification feature enables the device to locate the input port where the sensor is connected and self adjust when a sensor is removed or replaced. The device is able to collect physical data, whether or not a function of time. The sensor may also store a unique sensor identifier.

  1. Light-Stimulated Synaptic Devices Utilizing Interfacial Effect of Organic Field-Effect Transistors.

    PubMed

    Dai, Shilei; Wu, Xiaohan; Liu, Dapeng; Chu, Yingli; Wang, Kai; Yang, Ben; Huang, Jia

    2018-06-14

    Synaptic transistors stimulated by light waves or photons may offer advantages to the devices, such as wide bandwidth, ultrafast signal transmission, and robustness. However, previously reported light-stimulated synaptic devices generally require special photoelectric properties from the semiconductors and sophisticated device's architectures. In this work, a simple and effective strategy for fabricating light-stimulated synaptic transistors is provided by utilizing interface charge trapping effect of organic field-effect transistors (OFETs). Significantly, our devices exhibited highly synapselike behaviors, such as excitatory postsynaptic current (EPSC) and pair-pulse facilitation (PPF), and presented memory and learning ability. The EPSC decay, PPF curves, and forgetting behavior can be well expressed by mathematical equations for synaptic devices, indicating that interfacial charge trapping effect of OFETs can be utilized as a reliable strategy to realize organic light-stimulated synapses. Therefore, this work provides a simple and effective strategy for fabricating light-stimulated synaptic transistors with both memory and learning ability, which enlightens a new direction for developing neuromorphic devices.

  2. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  3. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  4. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  5. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  6. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  7. 21 CFR 892.2040 - Medical image hardcopy device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  8. 21 CFR 892.2040 - Medical image hardcopy device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  9. 21 CFR 892.2040 - Medical image hardcopy device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  10. 21 CFR 892.2040 - Medical image hardcopy device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  11. Effect of Dopant Activation on Device Characteristics of InGaN-based Light Emitting Diodes

    NASA Astrophysics Data System (ADS)

    Lacroce, Nicholas; Liu, Guangyu; Tan, Chee-Keong; Arif, Ronald A.; Lee, Soo Min; Tansu, Nelson

    2015-03-01

    Achieving high uniformity in growths and device characteristics of InGaN-based light-emitting diodes (LEDs) is important for large scale manufacturing. Dopant activation and maintaining control of variables affecting dopant activation are critical steps in the InGaN-based light emitting diodes (LEDs) fabrication process. In the epitaxy of large scale production LEDs, in-situ post-growth annealing is used for activating the Mg acceptor dopant in the p-AlGaN and p-GaN of the LEDs. However, the annealing temperature varies with respect to position in the reactor chamber, leading to severe uniform dopant activation issue across the devices. Thus, it is important to understand how the temperature gradient and the resulting variance in Mg acceptor activation will alter the device properties. In this work, we examine the effect of varying p-type doping levels in the p-GaN layers and AlGaN electron blocking layer of the GaN LEDs on the optoelectronic properties including the band profile, carrier concentration, current density, output power and quantum efficiency. By understanding the variations and its effect, the identification of the most critical p-type doping layer strategies to address this variation will be clarified.

  12. 76 FR 29006 - In the Matter of Certain Motion-Sensitive Sound Effects Devices and Image Display Devices and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-19

    ... Effects Devices and Image Display Devices and Components and Products Containing Same; Notice of... United States after importation of certain motion-sensitive sound effects devices and image display... devices and image display devices and components and products containing same that infringe one or more of...

  13. 21 CFR 880.6310 - Medical device data system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...

  14. 21 CFR 880.6310 - Medical device data system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...

  15. 21 CFR 880.6310 - Medical device data system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...

  16. 21 CFR 880.6310 - Medical device data system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...

  17. 21 CFR 864.9750 - Heat-sealing device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Heat-sealing device. 864.9750 Section 864.9750... and Blood Products § 864.9750 Heat-sealing device. (a) Identification. A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood...

  18. 21 CFR 864.9750 - Heat-sealing device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heat-sealing device. 864.9750 Section 864.9750... and Blood Products § 864.9750 Heat-sealing device. (a) Identification. A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood...

  19. 21 CFR 872.1745 - Laser fluorescence caries detection device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Laser fluorescence caries detection device. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries detection device. (a) Identification. A laser fluorescence caries detection device is a laser, a...

  20. 21 CFR 880.6785 - Manual patient transfer device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Miscellaneous Devices § 880.6785 Manual patient transfer device. (a) Identification. A manual patient transfer device is a device consisting of a wheeled stretcher and a mechanism on which a patient can be placed so... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient transfer device. 880.6785 Section...

  1. From Data Acquisition to Data Fusion: A Comprehensive Review and a Roadmap for the Identification of Activities of Daily Living Using Mobile Devices

    PubMed Central

    Pires, Ivan Miguel; Garcia, Nuno M.; Pombo, Nuno; Flórez-Revuelta, Francisco

    2016-01-01

    This paper focuses on the research on the state of the art for sensor fusion techniques, applied to the sensors embedded in mobile devices, as a means to help identify the mobile device user’s daily activities. Sensor data fusion techniques are used to consolidate the data collected from several sensors, increasing the reliability of the algorithms for the identification of the different activities. However, mobile devices have several constraints, e.g., low memory, low battery life and low processing power, and some data fusion techniques are not suited to this scenario. The main purpose of this paper is to present an overview of the state of the art to identify examples of sensor data fusion techniques that can be applied to the sensors available in mobile devices aiming to identify activities of daily living (ADLs). PMID:26848664

  2. 9 CFR 86.4 - Official identification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the ear); (iii) Malfunction of the electronic component of a radio frequency identification (RFID) device; or (iv) Incompatibility or inoperability of the electronic component of an RFID device with the management system or unacceptable functionality of the management system due to use of an RFID device. (2...

  3. 21 CFR 862.1675 - Blood specimen collection device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood specimen collection device. 862.1675 Section... Systems § 862.1675 Blood specimen collection device. (a) Identification. A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate...

  4. 21 CFR 862.1675 - Blood specimen collection device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood specimen collection device. 862.1675 Section... Systems § 862.1675 Blood specimen collection device. (a) Identification. A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate...

  5. 21 CFR 862.1675 - Blood specimen collection device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood specimen collection device. 862.1675 Section... Systems § 862.1675 Blood specimen collection device. (a) Identification. A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate...

  6. 21 CFR 862.1675 - Blood specimen collection device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood specimen collection device. 862.1675 Section... Systems § 862.1675 Blood specimen collection device. (a) Identification. A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate...

  7. 21 CFR 862.1675 - Blood specimen collection device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood specimen collection device. 862.1675 Section... Systems § 862.1675 Blood specimen collection device. (a) Identification. A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate...

  8. 21 CFR 876.5320 - Nonimplanted electrical continence device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonimplanted electrical continence device. 876... Nonimplanted electrical continence device. (a) Identification. A nonimplanted electrical continence device is a device that consists of a pair of electrodes on a plug or a pessary that are connected by an electrical...

  9. 21 CFR 876.5320 - Nonimplanted electrical continence device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonimplanted electrical continence device. 876... Nonimplanted electrical continence device. (a) Identification. A nonimplanted electrical continence device is a device that consists of a pair of electrodes on a plug or a pessary that are connected by an electrical...

  10. 21 CFR 876.5320 - Nonimplanted electrical continence device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonimplanted electrical continence device. 876... Nonimplanted electrical continence device. (a) Identification. A nonimplanted electrical continence device is a device that consists of a pair of electrodes on a plug or a pessary that are connected by an electrical...

  11. 21 CFR 876.5320 - Nonimplanted electrical continence device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonimplanted electrical continence device. 876... Nonimplanted electrical continence device. (a) Identification. A nonimplanted electrical continence device is a device that consists of a pair of electrodes on a plug or a pessary that are connected by an electrical...

  12. 33 CFR 159.55 - Identification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Identification. 159.55 Section 159.55 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.55 Identification. (a) Each...

  13. Accelerated Aging System for Prognostics of Power Semiconductor Devices

    NASA Technical Reports Server (NTRS)

    Celaya, Jose R.; Vashchenko, Vladislav; Wysocki, Philip; Saha, Sankalita

    2010-01-01

    Prognostics is an engineering discipline that focuses on estimation of the health state of a component and the prediction of its remaining useful life (RUL) before failure. Health state estimation is based on actual conditions and it is fundamental for the prediction of RUL under anticipated future usage. Failure of electronic devices is of great concern as future aircraft will see an increase of electronics to drive and control safety-critical equipment throughout the aircraft. Therefore, development of prognostics solutions for electronics is of key importance. This paper presents an accelerated aging system for gate-controlled power transistors. This system allows for the understanding of the effects of failure mechanisms, and the identification of leading indicators of failure which are essential in the development of physics-based degradation models and RUL prediction. In particular, this system isolates electrical overstress from thermal overstress. Also, this system allows for a precise control of internal temperatures, enabling the exploration of intrinsic failure mechanisms not related to the device packaging. By controlling the temperature within safe operation levels of the device, accelerated aging is induced by electrical overstress only, avoiding the generation of thermal cycles. The temperature is controlled by active thermal-electric units. Several electrical and thermal signals are measured in-situ and recorded for further analysis in the identification of leading indicators of failures. This system, therefore, provides a unique capability in the exploration of different failure mechanisms and the identification of precursors of failure that can be used to provide a health management solution for electronic devices.

  14. Analytical Device

    NASA Technical Reports Server (NTRS)

    1983-01-01

    In the mid 60s under contract with NASA, Dr. Benjamin W. Grunbaum was responsible for the development of an automated electrophoresis device that would work in the weightless environment of space. The device was never used in space but was revived during the mid 70s as a technology utilization project aimed at an automated system for use on Earth. The advanced system became known as the Grunbaum System for electrophoresis. It is a versatile, economical assembly for rapid separation of specific blood proteins in very small quantities, permitting their subsequent identification and quantification.

  15. 21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...

  16. 21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...

  17. 21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...

  18. 21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...

  19. 21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...

  20. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  1. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  2. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  3. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  4. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  5. 21 CFR 876.5270 - Implanted electrical urinary continence device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implanted electrical urinary continence device... Implanted electrical urinary continence device. (a) Identification. An implanted electrical urinary device is a device intended for treatment of urinary incontinence that consists of a receiver implanted in...

  6. 21 CFR 876.5270 - Implanted electrical urinary continence device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implanted electrical urinary continence device... Implanted electrical urinary continence device. (a) Identification. An implanted electrical urinary device is a device intended for treatment of urinary incontinence that consists of a receiver implanted in...

  7. 21 CFR 876.5270 - Implanted electrical urinary continence device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implanted electrical urinary continence device... Implanted electrical urinary continence device. (a) Identification. An implanted electrical urinary device is a device intended for treatment of urinary incontinence that consists of a receiver implanted in...

  8. 21 CFR 876.5270 - Implanted electrical urinary continence device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implanted electrical urinary continence device... Implanted electrical urinary continence device. (a) Identification. An implanted electrical urinary device is a device intended for treatment of urinary incontinence that consists of a receiver implanted in...

  9. 21 CFR 876.5270 - Implanted electrical urinary continence device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Implanted electrical urinary continence device. (a) Identification. An implanted electrical urinary device is a device intended for treatment of urinary incontinence that consists of a receiver implanted in... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted electrical urinary continence device...

  10. Design issues for semi-passive optical communication devices

    NASA Astrophysics Data System (ADS)

    Glaser, I.

    2007-09-01

    Optical smart cards are devices containing a retro-reflector, light modulator, and some computing and data storage capabilities to affect semi-passive communication. They do not produce light; instead they modulate and send back light received from a stationary unit. These devices can replace contact-based smart cards as well as RF based ones for applications ranging from identification to transmitting and validating data. Since their transmission is essentially focused on the receiving unit, they are harder to eavesdrop than RF devices, yet need no physical contact or alignment. In this paper we explore optical design issues of these devices and estimate their optical behavior. Specifically, we analyze how these compact devices can be optimized for selected application profiles. Some of the key parameters addressed are effective light efficiency (how much modulated signal can be received by the stationary unit given the amount of light it transmits), range of tilt angles (angle between device surface normal to the line connecting the optical smart card with the stationary unit) through which the device would be effective, and power requirements of the semi-passive unit. In addition, issues concerning compact packaging of this device are discussed. Finally, results of the analysis are employed to produce a comparison of achievable capabilities of these optical smart cards, as opposed to alternative devices, and discuss potential applications were they can be best utilized.

  11. 21 CFR 872.1820 - Dental x-ray exposure alignment device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...

  12. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  13. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  14. 21 CFR 872.1820 - Dental x-ray exposure alignment device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...

  15. 21 CFR 872.1820 - Dental x-ray exposure alignment device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...

  16. 21 CFR 872.1820 - Dental x-ray exposure alignment device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...

  17. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  18. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  19. 21 CFR 872.1820 - Dental x-ray exposure alignment device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...

  20. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  1. 21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...

  2. 21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...

  3. 21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...

  4. 21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...

  5. 21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...

  6. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  7. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  8. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  9. Tracking ion irradiation effects using buried interface devices

    NASA Astrophysics Data System (ADS)

    Cutshall, D. B.; Kulkarni, D. D.; Miller, A. J.; Harriss, J. E.; Harrell, W. R.; Sosolik, C. E.

    2018-05-01

    We discuss how a buried interface device, specifically a metal-oxide-semiconductor (MOS) capacitor, can be utilized to track effects of ion irradiation on insulators. We show that the exposure of oxides within unfinished capacitor devices to ions can lead to significant changes in the capacitance of the finished devices. For multicharged ions, these capacitive effects can be traced to defect production within the oxide and ultimately point to a role for charge-dependent energy loss. In particular, we attribute the stretchout of the capacitance-voltage curves of MOS devices that include an irradiated oxide to the ion irradiation. The stretchout shows a power law dependence on the multicharged ion charge state (Q) that is similar to that observed for multicharged ion energy loss in other systems.

  10. Dimensionality effects in chalcogenide-based devices

    NASA Astrophysics Data System (ADS)

    Kostylev, S. A.

    2013-06-01

    The multiplicity of fundamental bulk effects with small characteristic dimensions and short times and diversity of their combinations attracts a lot of researcher and industrialist attention in nanoelectronics and photonics to chalcogenide materials. Experimental data presented on dimensional effects of electrical chalcogenide switching (threshold voltage and threshold current dependence on device area and the film thickness), and in phase-change memory (switching, programming and read parameters), are analyzed from the point of view of choice of low dimensional materials with S-NDC and participation of electrical instabilities - high current density filaments. New ways of improving parameters of phase-change devices are proposed together with new criteria of material choice.

  11. Stimulus Probability Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  12. A randomized trial of standardized nursing patient assessment using wireless devices.

    PubMed

    Dykes, Patricia C; Carroll, Diane L; Benoit, Angela; Coakley, Amanda; Chang, Frank; Empoliti, Joanne; Gallagher, Joan; Lasala, Cynthia; O'Malley, Rosemary; Rath, Greg; Silva, Judy; Li, Qi

    2007-10-11

    A complete and accurate patient assessment database is essential for effective communication, problem identification, planning and evaluation of patient status. When employed consistently for point-of-care documentation, information systems are associated with completeness and quality of documentation. The purpose of this paper is to report on the findings of a randomized, cross-over study conducted to evaluate the adequacy of a standard patient assessment module to support problem identification, care planning and tracking of nursing sensitive patient outcomes. The feasibility of wireless devices to support patient assessment data collection at the point-of-care was evaluated using wireless PDAs and tablet PCs. Seventy-nine (79) nurses from two patient care units at Massachusetts General Hospital (Boston, MA) were recruited into the study and randomized to complete patient assessment using wireless or paper devices. At the end of six weeks, nurses who where randomized to the paper assessment module were assigned to a device and those who used a device were assigned to paper for an additional six weeks. Impact was evaluated with regard to data capture, workflow implications and nurse satisfaction. Findings suggest that a standard patient assessment set promotes patient sensitive and quality data capture, which is augmented by the use of wireless devices.

  13. A Randomized Trial of Standardized Nursing Patient Assessment Using Wireless Devices

    PubMed Central

    Dykes, Patricia C.; Carroll, Diane L.; Benoit, Angela; Coakley, Amanda; Chang, Frank; Empoliti, Joanne; Gallagher, Joan; Lasala, Cynthia; O’Malley, Rosemary; Rath, Greg; Silva, Judy; Li, Qi

    2007-01-01

    A complete and accurate patient assessment database is essential for effective communication, problem identification, planning and evaluation of patient status. When employed consistently for point-of-care documentation, information systems are associated with completeness and quality of documentation. The purpose of this paper is to report on the findings of a randomized, cross-over study conducted to evaluate the adequacy of a standard patient assessment module to support problem identification, care planning and tracking of nursing sensitive patient outcomes. The feasibility of wireless devices to support patient assessment data collection at the point-of-care was evaluated using wireless PDAs and tablet PCs. Seventy-nine (79) nurses from two patient care units at Massachusetts General Hospital (Boston, MA) were recruited into the study and randomized to complete patient assessment using wireless or paper devices. At the end of six weeks, nurses who where randomized to the paper assessment module were assigned to a device and those who used a device were assigned to paper for an additional six weeks. Impact was evaluated with regard to data capture, workflow implications and nurse satisfaction. Findings suggest that a standard patient assessment set promotes patient sensitive and quality data capture, which is augmented by the use of wireless devices. PMID:18693827

  14. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual blood cell counting device. 864.6160...

  15. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual blood cell counting device. 864.6160...

  16. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual blood cell counting device. 864.6160...

  17. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual blood cell counting device. 864.6160...

  18. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general...

  19. Implantation reduces the negative effects of bio-logging devices on birds.

    PubMed

    White, Craig R; Cassey, Phillip; Schimpf, Natalie G; Halsey, Lewis G; Green, Jonathan A; Portugal, Steven J

    2013-02-15

    Animal-borne logging or telemetry devices are widely used for measurements of physiological and movement data from free-living animals. For such measurements to be relevant, however, it is essential that the devices themselves do not affect the data of interest. A recent meta-analysis reported an overall negative effect of these devices on the birds that bear them, i.e. on nesting productivity, clutch size, nest initiation date, offspring quality, body condition, flying ability, foraging behaviours, energy expenditure and survival rate. Method of attachment (harness, collar, glue, anchor, implant, breast-mounted or tailmount) had no influence on the strength of these effects but anchored and implanted transmitters had the highest reported rates of device-induced mortality. Furthermore, external devices, but not internal devices, caused an increase in 'device-induced behaviour' (comfort behaviours such as preening, fluffing and stretching, and unrest activities including unquantifiable 'active' behaviours). These findings suggest that, with the exception of device-induced behaviour, external attachment is preferable to implantation. In the present study we undertake a meta-analysis of 183 estimates of device impact from 39 studies of 36 species of bird designed to explicitly compare the effects of externally attached and surgically implanted devices on a range of traits, including condition, energy expenditure and reproduction. In contrast to a previous study, we demonstrate that externally attached devices have a consistent detrimental effect (i.e. negative influences on body condition, reproduction, metabolism and survival), whereas implanted devices have no consistent effect. We also show that the magnitude of the negative effect of externally attached devices decreases with time. We therefore conclude that device implantation is preferable to external attachment, providing that the risk of mortality associated with the anaesthesia and surgery required for

  20. RFID and Memory Devices Fabricated Integrally on Substrates

    NASA Technical Reports Server (NTRS)

    Schramm, Harry F.

    2004-01-01

    Electronic identification devices containing radio-frequency identification (RFID) circuits and antennas would be fabricated integrally with the objects to be identified, according to a proposal. That is to say, the objects to be identified would serve as substrates for the deposition and patterning of the materials of the devices used to identify them, and each identification device would be bonded to the identified object at the molecular level. Vacuum arc vapor deposition (VAVD) is the NASA derived process for depositing layers of material on the substrate. This proposal stands in contrast to the current practice of fabricating RFID and/or memory devices as wafer-based, self-contained integrated-circuit chips that are subsequently embedded in or attached to plastic cards to make smart account-information cards and identification badges. If one relies on such a chip to store data on the history of an object to be tracked and the chip falls off or out of the object, then one loses both the historical data and the means to track the object and verify its identity electronically. Also, in contrast is the manufacturing philosophy in use today to make many memory devices. Today s methods involve many subtractive processes such as etching. This proposal only uses additive methods, building RFID and memory devices from the substrate up in thin layers. VAVD is capable of spraying silicon, copper, and other materials commonly used in electronic devices. The VAVD process sprays most metals and some ceramics. The material being sprayed has a very strong bond with the substrate, whether that substrate is metal, ceramic, or even wood, rock, glass, PVC, or paper. An object to be tagged with an identification device according to the proposal must be compatible with a vacuum deposition process. Temperature is seldom an issue as the substrate rarely reaches 150 F (66 C) during the deposition process. A portion of the surface of the object would be designated as a substrate for

  1. 21 CFR 882.5050 - Biofeedback device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Biofeedback device. 882.5050 Section 882.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...) Identification. A biofeedback device is an instrument that provides a visual or auditory signal corresponding to...

  2. Radiofrequency Identification

    PubMed Central

    Jones, Terry L.

    2017-01-01

    A national campaign is underway to increase the amount of time staff nurses spend at the bedside of hospitalized patients through redesign of the work environment. This kind of work redesign requires robust data depicting what nurses do and how they spend their time. Historically, these kinds of data have been difficult, costly, and time consuming to collect. Wireless capture of data on the movement of humans within the work environment (ie, time and motion) is now possible through radiofrequency identification technology. When small tracking devices the size of a quarter are affixed to their clothing, the movement of nurses throughout a patient care unit can be monitored. The duration and frequency of patient interaction are captured along with the duration of time spent in other locations of interest to include nurses’ station, supply room, medication room, doctors’ station, electronic documentation stations, family waiting rooms, and the hallway. Patterns of nurse movement and time allocation can be efficiently identified, and the effects of staffing practices, workflows, and unit layout evaluated. Integration of radiofrequency identification time and motion data with other databases enables nurse leaders to link nursing time to important cost and quality outcomes. Nurse leaders should explore the usefulness of radiofrequency identification technology in addressing data needs for nurse time and motion. PMID:22592451

  3. Homogeneous illusion device exhibiting transformed and shifted scattering effect

    NASA Astrophysics Data System (ADS)

    Mei, Jin-Shuo; Wu, Qun; Zhang, Kuang; He, Xun-Jun; Wang, Yue

    2016-06-01

    Based on the theory of transformation optics, a type of homogeneous illusion device exhibiting transformed and shifted scattering effect is proposed in this paper. The constitutive parameters of the proposed device are derived, and full-wave simulations are performed to validate the electromagnetic properties of transformed and shifted scattering effect. The simulation results show that the proposed device not only can visually shift the image of target in two dimensions, but also can visually transform the shape of target. It is expected that such homogeneous illusion device could possess potential applications in military camouflage and other field of electromagnetic engineering.

  4. 21 CFR 864.5950 - Blood volume measuring device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood volume measuring device. 864.5950 Section...

  5. 21 CFR 864.5950 - Blood volume measuring device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section...

  6. 21 CFR 864.5950 - Blood volume measuring device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood volume measuring device. 864.5950 Section...

  7. 21 CFR 864.5950 - Blood volume measuring device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood volume measuring device. 864.5950 Section...

  8. 21 CFR 864.5950 - Blood volume measuring device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood volume measuring device. 864.5950 Section...

  9. Graphene field-effect devices

    NASA Astrophysics Data System (ADS)

    Echtermeyer, T. J.; Lemme, M. C.; Bolten, J.; Baus, M.; Ramsteiner, M.; Kurz, H.

    2007-09-01

    In this article, graphene is investigated with respect to its electronic properties when introduced into field effect devices (FED). With the exception of manual graphene deposition, conventional top-down CMOS-compatible processes are applied. Few and monolayer graphene sheets are characterized by scanning electron microscopy, atomic force microscopy and Raman spectroscopy. The electrical properties of monolayer graphene sandwiched between two silicon dioxide films are studied. Carrier mobilities in graphene pseudo-MOS structures are compared to those obtained from double-gated Graphene-FEDs and silicon metal-oxide-semiconductor field-effect-transistors (MOSFETs).

  10. Identification and validation of nebulized aerosol devices for sputum induction

    PubMed Central

    Davidson, Warren J; Dennis, John; The, Stephanie; Litoski, Belinda; Pieron, Cora; Leigh, Richard

    2014-01-01

    Induced sputum cell count measurement has proven reliability for evaluating airway inflammation in patients with asthma and other airway diseases. Although the use of nebulizer devices for sputum induction is commonplace, they are generally labelled as single-patient devices by the manufacturer and, therefore, cannot be used for multiple patients in large clinical sputum induction programs due to infect ion-control requirements. Accordingly, this study investigated the aerosol characteristics of alternative devices that could be used in such programs. BACKGROUND: Induced sputum cell counts are a noninvasive and reliable method for evaluating the presence, type and degree of airway inflammation in patients with asthma. Currently, standard nebulizer devices used for sputum induction in multiple patients are labelled as single-patient devices by the manufacturer, which conflicts with infection prevention and control requirements. As such, these devices cannot feasibly be used in a clinical sputum induction program. Therefore, there is a need to identify alternative nebulizer devices that are either disposable or labelled for multi-patient use. OBJECTIVE: To apply validated rigorous, scientific testing methods to identify and validate commercially available nebulizer devices appropriate for use in a clinical sputum induction program. METHODS: Measurement of nebulized aerosol output and size for the selected nebulizer designs followed robust International Organization for Standardization methods. Sputum induction using two of these nebulizers was successfully performed on 10 healthy adult subjects. The cytotechnologist performing sputum cell counts was blinded to the type of nebulizer used. RESULTS: The studied nebulizers had variable aerosol outputs. The AeroNeb Solo (Aerogen, Ireland), Omron NE-U17 (Omron, Japan) and EASYneb II (Flaem Nuova, Italy) systems were found to have similar measurements of aerosol size. There was no significant difference in induced sputum

  11. Single-Event Effects in Silicon Carbide Power Devices

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Ikpe, Stanley; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.

    2015-01-01

    This report summarizes the NASA Electronic Parts and Packaging Program Silicon Carbide Power Device Subtask efforts in FY15. Benefits of SiC are described and example NASA Programs and Projects desiring this technology are given. The current status of the radiation tolerance of silicon carbide power devices is given and paths forward in the effort to develop heavy-ion single-event effect hardened devices indicated.

  12. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  13. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  14. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  15. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  16. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  17. 21 CFR 886.1430 - Ophthalmic contact lens radius measuring device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic contact lens radius measuring device... lens radius measuring device. (a) Identification. An ophthalmic contact lens radius measuring device is... lens. (b) Classification. Class I (general controls). The device is exempt from the premarket...

  18. Identification of inorganic improvised explosive devices using sequential injection capillary electrophoresis and contactless conductivity detection.

    PubMed

    Blanco, Gustavo A; Nai, Yi H; Hilder, Emily F; Shellie, Robert A; Dicinoski, Greg W; Haddad, Paul R; Breadmore, Michael C

    2011-12-01

    A simple sequential injection capillary electrophoresis (SI-CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) has been developed for the rapid separation of anions relevant to the identification of inorganic improvised explosive devices (IEDs). Four of the most common explosive tracer ions, nitrate, perchlorate, chlorate, and azide, and the most common background ions, chloride, sulfate, thiocyanate, fluoride, phosphate, and carbonate, were chosen for investigation. Using a separation electrolyte comprising 50 mM tris(hydroxymethyl)aminomethane, 50 mM cyclohexyl-2-aminoethanesulfonic acid, pH 8.9 and 0.05% poly(ethyleneimine) (PEI) in a hexadimethrine bromide (HDMB)-coated capillary it was possible to partially separate all 10 ions within 90 s. The combination of two cationic polymer additives (PEI and HDMB) was necessary to achieve adequate selectivity with a sufficiently stable electroosmotic flow (EOF), which was not possible with only one polymer. Careful optimization of variables affecting the speed of separation and injection timing allowed a further reduction of separation time to 55 s while maintaining adequate efficiency and resolution. Software control makes high sample throughput possible (60 samples/h), with very high repeatability of migration times [0.63-2.07% relative standard deviation (RSD) for 240 injections]. The separation speed does not compromise sensitivity, with limits of detection ranging from 23 to 50 μg·L(-1) for all the explosive residues considered, which is 10× lower than those achieved by indirect absorbance detection and 2× lower than those achieved by C(4)D using portable benchtop instrumentation. The combination of automation, high sample throughput, high confidence of peak identification, and low limits of detection makes this methodology ideal for the rapid identification of inorganic IED residues.

  19. Long-term effectiveness of the SpeechEasy fluency-enhancement device.

    PubMed

    Gallop, Ronald F; Runyan, Charles M

    2012-12-01

    The SpeechEasy has been found to be an effective device for reduction of stuttering frequency for many people who stutter (PWS); published studies typically have compared stuttering reduction at initial fitting of the device to results achieved up to one year later. This study examines long-term effectiveness by examining whether effects of the SpeechEasy were maintained for longer periods, from 13 to 59 months. Results indicated no significant change for seven device users from post-fitting to the time of the study (t=-.074, p=.943); however, findings varied greatly on a case-by-case basis. Most notably, when stuttering frequency for eleven users and former users, prior to device fitting, was compared to current stuttering frequency while not wearing the device, the change over time was found to be statistically significant (t=2.851, p=.017), suggesting a carry-over effect of the device. There was no significant difference in stuttering frequency when users were wearing versus not wearing the device currently (t=1.949, p=0.92). Examinations of these results, as well as direction for future research, are described herein. The reader will be able to: (a) identify and briefly describe two types of altered auditory feedback which the SpeechEasy incorporates in order to help reduce stuttering; (b) describe the carry-over effect found in this study, suggest effectiveness associated with the device over a longer period of time than previously reported, as well as its implications, and (c) list factors that might be assessed in future research involving this device in order to more narrowly determine which prospective users are most likely to benefit from employing the SpeechEasy. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Identification of trimannoside-recognizing peptide sequences from a T7 phage display screen using a QCM device.

    PubMed

    Nishiyama, Kazusa; Takakusagi, Yoichi; Kusayanagi, Tomoe; Matsumoto, Yuki; Habu, Shiori; Kuramochi, Kouji; Sugawara, Fumio; Sakaguchi, Kengo; Takahashi, Hideyo; Natsugari, Hideaki; Kobayashi, Susumu

    2009-01-01

    Here, we report on the identification of trimannoside-recognizing peptide sequences from a T7 phage display screen using a quartz-crystal microbalance (QCM) device. A trimannoside derivative that can form a self-assembled monolayer (SAM) was synthesized and used for immobilization on the gold electrode surface of a QCM sensor chip. After six sets of one-cycle affinity selection, T7 phage particles displaying PSVGLFTH (8-mer) and SVGLGLGFSTVNCF (14-mer) were found to be enriched at a rate of 17/44, 9/44, respectively, suggesting that these peptides specifically recognize trimannoside. Binding checks using the respective single T7 phage and synthetic peptide also confirmed the specific binding of these sequences to the trimannoside-SAM. Subsequent analysis revealed that these sequences correspond to part of the primary amino acid sequence found in many mannose- or hexose-related proteins. Taken together, these results demonstrate the effectiveness of our T7 phage display environment for affinity selection of binding peptides. We anticipate this screening result will also be extremely useful in the development of inhibitors or drug delivery systems targeting polysaccharides as well as further investigations into the function of carbohydrates in vivo.

  1. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    PubMed

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  2. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  3. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  4. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  5. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  6. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  7. 21 CFR 801.40 - Form of a unique device identifier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Automatic identification and data capture (AIDC) technology. (b) The UDI must include a device identifier... evident upon visual examination of the label or device package, the label or device package must disclose... label and device packages is deemed to meet all requirements of subpart B of this part. The UPC will...

  8. 21 CFR 882.1540 - Galvanic skin response measurement device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Galvanic skin response measurement device. 882... Galvanic skin response measurement device. (a) Identification. A galvanic skin response measurement device... electrical resistance of the skin and the tissue path between two electrodes applied to the skin. (b...

  9. 21 CFR 882.1540 - Galvanic skin response measurement device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Galvanic skin response measurement device. 882... Galvanic skin response measurement device. (a) Identification. A galvanic skin response measurement device... electrical resistance of the skin and the tissue path between two electrodes applied to the skin. (b...

  10. 21 CFR 882.1540 - Galvanic skin response measurement device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Galvanic skin response measurement device. 882... Galvanic skin response measurement device. (a) Identification. A galvanic skin response measurement device... electrical resistance of the skin and the tissue path between two electrodes applied to the skin. (b...

  11. 21 CFR 882.1540 - Galvanic skin response measurement device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Galvanic skin response measurement device. 882... Galvanic skin response measurement device. (a) Identification. A galvanic skin response measurement device... electrical resistance of the skin and the tissue path between two electrodes applied to the skin. (b...

  12. Identification of the Emplacement of Improvised Explosive Devices by Experienced Mission Payload Operators.

    PubMed

    McNeese, Nathan J; Cooke, Nancy J; Branaghan, Russell; Knobloch, Ashley; Taylor, Amanda

    2017-04-01

    Improvised Explosive Devices (IEDs) have become one of the deadliest threats to military personnel, resulting in over 50% of American combat casualties in Iraq and Afghanistan. Identification of IED emplacement is conducted by mission payload operators (MPOs). Yet, experienced MPOs are limited in number, making MPO training a critical intervention. In this article, we implement a Cognitive Engineering Based on Expert Skill methodology to better understand how experienced MPOs identify the emplacement of IEDs for the purposes of improving training. First, expert knowledge was elicited through interviews and questionnaires to identify the types of perceptual cues used and how these cues are cognitively processed. Results indicate that there are many different static and dynamic cues that interact with each other over time and space. Using data from the interviews and questionnaires, an empirically grounded framework is presented that explains the cognitive process of IED emplacement detection. Using the overall findings and the framework, IED emplacement training scenarios were developed and built into a simulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. 21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...

  14. Radiation Effects in III-V Nanowire Devices

    DTIC Science & Technology

    2016-09-01

    Nanowire Devices Distribution Statement A. Approved for public release; distribution is unlimited. September 2016 HDTRA1-11-1-0021 Steven R...Name: Prof. S. R. J. Brueck Organization/Institution: University of New Mexico Project Title: Radiation Effects in III-V Nanowire Devices What are...the agency approved application or plan. The objectives of this program were to: a) develop a new nanowire transistor technology based on nanoscale

  15. Minimalist identification system based on venous map for security applications

    NASA Astrophysics Data System (ADS)

    Jacinto G., Edwar; Martínez S., Fredy; Martínez S., Fernando

    2015-07-01

    This paper proposes a technique and an algorithm used to build a device for people identification through the processing of a low resolution camera image. The infrared channel is the only information needed, sensing the blood reaction with the proper wave length, and getting a preliminary snapshot of the vascular map of the back side of the hand. The software uses this information to extract the characteristics of the user in a limited area (region of interest, ROI), unique for each user, which applicable to biometric access control devices. This kind of recognition prototypes functions are expensive, but in this case (minimalist design), the biometric equipment only used a low cost camera and the matrix of IR emitters adaptation to construct an economic and versatile prototype, without neglecting the high level of effectiveness that characterizes this kind of identification method.

  16. 21 CFR 876.5280 - Implanted mechanical/hydraulic urinary continence device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted mechanical/hydraulic urinary continence....5280 Implanted mechanical/hydraulic urinary continence device. (a) Identification. An implanted mechanical/hydraulic urinary continence device is a device used to treat urinary incontinence by the...

  17. 21 CFR 876.5280 - Implanted mechanical/hydraulic urinary continence device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implanted mechanical/hydraulic urinary continence....5280 Implanted mechanical/hydraulic urinary continence device. (a) Identification. An implanted mechanical/hydraulic urinary continence device is a device used to treat urinary incontinence by the...

  18. 21 CFR 876.5280 - Implanted mechanical/hydraulic urinary continence device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implanted mechanical/hydraulic urinary continence....5280 Implanted mechanical/hydraulic urinary continence device. (a) Identification. An implanted mechanical/hydraulic urinary continence device is a device used to treat urinary incontinence by the...

  19. 21 CFR 876.5280 - Implanted mechanical/hydraulic urinary continence device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implanted mechanical/hydraulic urinary continence....5280 Implanted mechanical/hydraulic urinary continence device. (a) Identification. An implanted mechanical/hydraulic urinary continence device is a device used to treat urinary incontinence by the...

  20. 21 CFR 876.5280 - Implanted mechanical/hydraulic urinary continence device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implanted mechanical/hydraulic urinary continence....5280 Implanted mechanical/hydraulic urinary continence device. (a) Identification. An implanted mechanical/hydraulic urinary continence device is a device used to treat urinary incontinence by the...

  1. A concept ideation framework for medical device design.

    PubMed

    Hagedorn, Thomas J; Grosse, Ian R; Krishnamurty, Sundar

    2015-06-01

    Medical device design is a challenging process, often requiring collaboration between medical and engineering domain experts. This collaboration can be best institutionalized through systematic knowledge transfer between the two domains coupled with effective knowledge management throughout the design innovation process. Toward this goal, we present the development of a semantic framework for medical device design that unifies a large medical ontology with detailed engineering functional models along with the repository of design innovation information contained in the US Patent Database. As part of our development, existing medical, engineering, and patent document ontologies were modified and interlinked to create a comprehensive medical device innovation and design tool with appropriate properties and semantic relations to facilitate knowledge capture, enrich existing knowledge, and enable effective knowledge reuse for different scenarios. The result is a Concept Ideation Framework for Medical Device Design (CIFMeDD). Key features of the resulting framework include function-based searching and automated inter-domain reasoning to uniquely enable identification of functionally similar procedures, tools, and inventions from multiple domains based on simple semantic searches. The significance and usefulness of the resulting framework for aiding in conceptual design and innovation in the medical realm are explored via two case studies examining medical device design problems. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. An UV photochromic memory effect in proton-based WO3 electrochromic devices

    NASA Astrophysics Data System (ADS)

    Zhang, Yong; Lee, S.-H.; Mascarenhas, A.; Deb, S. K.

    2008-11-01

    We report an UV photochromic memory effect on a standard proton-based WO3 electrochromic device. It exhibits two memory states, associated with the colored and bleached states of the device, respectively. Such an effect can be used to enhance device performance (increasing the dynamic range), re-energize commercial electrochromic devices, and develop memory devices.

  3. 21 CFR 864.9205 - Blood and plasma warming device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood and plasma warming device. 864.9205 Section... Blood and Blood Products § 864.9205 Blood and plasma warming device. (a) Nonelectromagnetic blood or plasma warming device—(1) Identification. A nonelectromagnetic blood and plasma warming device is a...

  4. 21 CFR 864.9205 - Blood and plasma warming device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood and plasma warming device. 864.9205 Section... Blood and Blood Products § 864.9205 Blood and plasma warming device. (a) Nonelectromagnetic blood or plasma warming device—(1) Identification. A nonelectromagnetic blood and plasma warming device is a...

  5. 21 CFR 864.9205 - Blood and plasma warming device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood and plasma warming device. 864.9205 Section... Blood and Blood Products § 864.9205 Blood and plasma warming device. (a) Nonelectromagnetic blood or plasma warming device—(1) Identification. A nonelectromagnetic blood and plasma warming device is a...

  6. 21 CFR 864.9205 - Blood and plasma warming device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood and plasma warming device. 864.9205 Section... Blood and Blood Products § 864.9205 Blood and plasma warming device. (a) Nonelectromagnetic blood or plasma warming device—(1) Identification. A nonelectromagnetic blood and plasma warming device is a...

  7. 21 CFR 864.9205 - Blood and plasma warming device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood and plasma warming device. 864.9205 Section... Blood and Blood Products § 864.9205 Blood and plasma warming device. (a) Nonelectromagnetic blood or plasma warming device—(1) Identification. A nonelectromagnetic blood and plasma warming device is a...

  8. Charge coupled devices

    NASA Technical Reports Server (NTRS)

    Walker, J. W.; Hornbeck, L. J.; Stubbs, D. P.

    1977-01-01

    The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

  9. 33 CFR 101.310 - Additional communication devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...

  10. 33 CFR 101.310 - Additional communication devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...

  11. 33 CFR 101.310 - Additional communication devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...

  12. 33 CFR 101.310 - Additional communication devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...

  13. 33 CFR 101.310 - Additional communication devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... communication devices. (a) Alert Systems. Alert systems, such as the ship security alert system required in... part 104, 105, or 106 of this subchapter. (b) Automated Identification Systems (AIS). AIS may be used... plan under part 104 of this subchapter. See 33 CFR part 164 for additional information on AIS device...

  14. Does methodology matter in eyewitness identification research? The effect of live versus video exposure on eyewitness identification accuracy.

    PubMed

    Pozzulo, Joanna D; Crescini, Charmagne; Panton, Tasha

    2008-01-01

    The present study examined the effect of mode of target exposure (live versus video) on eyewitness identification accuracy. Adult participants (N=104) were exposed to a staged crime that they witnessed either live or on videotape. Participants were then asked to rate their stress and arousal levels prior to being presented with either a target-present or -absent simultaneous lineup. Across target-present and -absent lineups, mode of target exposure did not have a significant effect on identification accuracy. However, mode of target exposure was found to have a significant effect on stress and arousal levels. Participants who witnessed the crime live had higher levels of stress and arousal than those who were exposed to the videotaped crime. A higher level of arousal was significantly related to poorer identification accuracy for those in the video condition. For participants in the live condition however, stress and arousal had no effect on eyewitness identification accuracy. Implications of these findings in regards to the generalizability of laboratory-based research on eyewitness testimony to real-life crime are discussed.

  15. The role of identification in dynamic psychiatry and psychotherapy.

    PubMed

    Corradi, Richard B

    2011-01-01

    Identification-a psychic process in which a person takes on characteristics of another-is a concept important to the understanding of human nature. It plays an important role in how our personalities develop, in our ability to deal with life's stresses, and in how we interact with other people. Knowledge of its manifestations is essential to dynamic psychiatry and to its applications in psychotherapy. This article defines identification and reviews its role in development and as a defense. It discusses its role in the psychopathology of disorders commonly encountered in psychotherapy practice-depression and anxiety states reactive to losses in life, and borderline states. Clinical vignettes illustrate how identification functions in these conditions, and also how identifications reveal themselves in the transference and are utilized in psychotherapy. A teaching vignette illustrates how important it is that residents learning the art of psychotherapy appreciate the therapeutic potential of identification. The article maintains that, although it often goes unrecognized, identification with the therapist is one of the most effective therapeutic devices in the transference.

  16. Mug shot exposure prior to lineup identification: interference, transference, and commitment effects.

    PubMed

    Dysart, J E; Lindsay, R C; Hammond, R; Dupuis, P

    2001-12-01

    The effects of viewing mug shots on subsequent identification performance are as yet unclear. Two experiments used a live staged-crime paradigm to determine if interpolated eyewitness exposure to mug shots caused interference, unconscious transference, or commitment effects influencing subsequent lineup accuracy. Experiment 1 (N = 104) tested interference effects. Similar correct decision rates were obtained for the mug shot and no mug shot groups from both perpetrator-present and absent lineups. Experiment 2 (N = 132) tested for commitment and transference effects. Results showed that the commitment group made significantly more incorrect identifications than either the control or the transference group, which had similar false-identification rates. Commitment effects present a serious threat to identification accuracy from lineups following mug shot searches.

  17. Effect of dielectric layers on device stability of pentacene-based field-effect transistors.

    PubMed

    Di, Chong-an; Yu, Gui; Liu, Yunqi; Guo, Yunlong; Sun, Xiangnan; Zheng, Jian; Wen, Yugeng; Wang, Ying; Wu, Weiping; Zhu, Daoben

    2009-09-07

    We report stable organic field-effect transistors (OFETs) based on pentacene. It was found that device stability strongly depends on the dielectric layer. Pentacene thin-film transistors based on the bare or polystyrene-modified SiO(2) gate dielectrics exhibit excellent electrical stabilities. In contrast, the devices with the octadecyltrichlorosilane (OTS)-treated SiO(2) dielectric layer showed the worst stabilities. The effects of the different dielectrics on the device stabilities were investigated. We found that the surface energy of the gate dielectric plays a crucial role in determining the stability of the pentacene thin film, device performance and degradation of electrical properties. Pentacene aggregation, phase transfer and film morphology are also important factors that influence the device stability of pentacene devices. As a result of the surface energy mismatch between the dielectric layer and organic semiconductor, the electronic performance was degraded. Moreover, when pentacene was deposited on the OTS-treated SiO(2) dielectric layer with very low surface energy, pentacene aggregation occurred and resulted in a dramatic decrease of device performance. These results demonstrated that the stable OFETs could be obtained by using pentacene as a semiconductor layer.

  18. 21 CFR 888.3045 - Resorbable calcium salt bone void filler device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...

  19. 21 CFR 888.3045 - Resorbable calcium salt bone void filler device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...

  20. 21 CFR 888.3045 - Resorbable calcium salt bone void filler device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...

  1. 21 CFR 888.3045 - Resorbable calcium salt bone void filler device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...

  2. 21 CFR 888.3045 - Resorbable calcium salt bone void filler device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...

  3. A comparison of statistical methods for evaluating matching performance of a biometric identification device: a preliminary report

    NASA Astrophysics Data System (ADS)

    Schuckers, Michael E.; Hawley, Anne; Livingstone, Katie; Mramba, Nona

    2004-08-01

    Confidence intervals are an important way to assess and estimate a parameter. In the case of biometric identification devices, several approaches to confidence intervals for an error rate have been proposed. Here we evaluate six of these methods. To complete this evaluation, we simulate data from a wide variety of parameter values. This data are simulated via a correlated binary distribution. We then determine how well these methods do at what they say they do: capturing the parameter inside the confidence interval. In addition, the average widths of the various confidence intervals are recorded for each set of parameters. The complete results of this simulation are presented graphically for easy comparison. We conclude by making a recommendation regarding which method performs best.

  4. Long-Term Effectiveness of the SpeechEasy Fluency-Enhancement Device

    ERIC Educational Resources Information Center

    Gallop, Ronald F.; Runyan, Charles M.

    2012-01-01

    The SpeechEasy has been found to be an effective device for reduction of stuttering frequency for many people who stutter (PWS); published studies typically have compared stuttering reduction at initial fitting of the device to results achieved up to one year later. This study examines long-term effectiveness by examining whether effects of the…

  5. Identification of chemical warfare agents using a portable microchip-based detection device

    NASA Astrophysics Data System (ADS)

    Petkovic-Duran, K.; Swallow, A.; Sexton, B. A.; Glenn, F.; Zhu, Y.

    2011-12-01

    Analysis of chemical warfare agents (CWAs) and their degradation products is an important verification component in support of the Chemical Weapons Convention and urgently demanding rapid and reliable analytical methods. A portable microchip electrophoresis (ME) device with contactless conductivity (CCD) detection was developed for the in situ identification of CWA and their degradation products. A 10mM MES/His, 0.4mM CTAB - based separation electrolyte accomplished the analysis of Sarin (GB), Tabun( GA) and Soman (GD) in less than 1 min, which is the fastest screening of nerve agents achieved with portable ME and CCD based detection methods to date. Reproducibility of detection was successfully demonstrated on simultaneous detection of GB (200ppm) and GA (278ppm). Reasonable agreement for the four consecutive runs was achieved with the mean peak time for Sarin of 29.15s, and the standard error of 0.58s or 2%. GD and GA were simultaneously detected with their degradation products methylphosphonic acid (MPA), pinacolyl methylphosphonic acid (PMPA) and O-Ethyl Phosphorocyanidate (GAHP and GAHP1) respectively. The detection limit for Sarin was around 35ppb. To the best of our knowledge this is the best result achieved in microchip electrophoresis and contactless conductivity based detection to date.

  6. Proton irradiation effects on gallium nitride-based devices

    NASA Astrophysics Data System (ADS)

    Karmarkar, Aditya P.

    Proton radiation effects on state-of-the-art gallium nitride-based devices were studied using Schottky diodes and high electron-mobility transistors. The device degradation was studied over a wide range of proton fluences. This study allowed for a correlation between proton irradiation effects between different types of devices and enhanced the understanding of the mechanisms responsible for radiation damage in GaN-based devices. Proton irradiation causes reduced carrier concentration and increased series resistance and ideality factor in Schottky diodes. 1.0-MeV protons cause greater degradation than 1.8-MeV protons because of their higher non-ionizing energy loss. The displacement damage in Schottky diodes recovers during annealing. High electron-mobility transistors exhibit extremely high radiation tolerance, continuing to perform up to a fluence of ˜1014 cm-2 of 1.8-MeV protons. Proton irradiation creates defect complexes in the thin-film structure. Decreased sheet carrier mobility due to increased carrier scattering and decreased sheet carrier density due to carrier removal by the defect centers are the primary damage mechanisms. Interface disorder at either the Schottky or the Ohmic contact plays a relatively unimportant part in overall device degradation in both Schottky diodes and high electron-mobility transistors.

  7. Speech-generating devices: effectiveness of interface design-a comparative study of autism spectrum disorders.

    PubMed

    Chen, Chien-Hsu; Wang, Chuan-Po; Lee, I-Jui; Su, Chris Chun-Chin

    2016-01-01

    We analyzed the efficacy of the interface design of speech generating devices on three non-verbal adolescents with autism spectrum disorder (ASD), in hopes of improving their on-campus communication and cognitive disability. The intervention program was created based on their social and communication needs in school. Two operating interfaces were designed and compared: the Hierarchical Relating Menu and the Pie Abbreviation-Expansion Menu. The experiment used the ABCACB multiple-treatment reversal design. The test items included: (1) accuracy of operating identification; (2) interface operation in response to questions; (3) degree of independent completion. Each of these three items improved with both intervention interfaces. The children were able to operate the interfaces skillfully and respond to questions accurately, which evidenced the effectiveness of the interfaces. We conclude that both interfaces are efficacious enough to help nonverbal children with ASD at different levels.

  8. Nosewitness Identification: Effects of Lineup Size and Retention Interval.

    PubMed

    Alho, Laura; Soares, Sandra C; Costa, Liliana P; Pinto, Elisa; Ferreira, Jacqueline H T; Sorjonen, Kimmo; Silva, Carlos F; Olsson, Mats J

    2016-01-01

    Although canine identification of body odor (BO) has been widely used as forensic evidence, the concept of nosewitness identification by human observers was only recently put to the test. The results indicated that BOs associated with male characters in authentic crime videos could later be identified in BO lineup tests well above chance. To further evaluate nosewitness memory, we assessed the effects of lineup size (Experiment 1) and retention interval (Experiment 2), using a forced-choice memory test. The results showed that nosewitness identification works for all lineup sizes (3, 5, and 8 BOs), but that larger lineups compromise identification performance in similarity to observations from eye- and earwitness studies. Also in line with previous eye- and earwitness studies, but in disagreement with some studies on odor memory, Experiment 2 showed significant forgetting between shorter retention intervals (15 min) and longer retention intervals (1-week) using lineups of five BOs. Altogether this study shows that identification of BO in a forensic setting is possible and has limits and characteristics in line with witness identification through other sensory modalities.

  9. Nosewitness Identification: Effects of Lineup Size and Retention Interval

    PubMed Central

    Alho, Laura; Soares, Sandra C.; Costa, Liliana P.; Pinto, Elisa; Ferreira, Jacqueline H. T.; Sorjonen, Kimmo; Silva, Carlos F.; Olsson, Mats J.

    2016-01-01

    Although canine identification of body odor (BO) has been widely used as forensic evidence, the concept of nosewitness identification by human observers was only recently put to the test. The results indicated that BOs associated with male characters in authentic crime videos could later be identified in BO lineup tests well above chance. To further evaluate nosewitness memory, we assessed the effects of lineup size (Experiment 1) and retention interval (Experiment 2), using a forced-choice memory test. The results showed that nosewitness identification works for all lineup sizes (3, 5, and 8 BOs), but that larger lineups compromise identification performance in similarity to observations from eye- and earwitness studies. Also in line with previous eye- and earwitness studies, but in disagreement with some studies on odor memory, Experiment 2 showed significant forgetting between shorter retention intervals (15 min) and longer retention intervals (1-week) using lineups of five BOs. Altogether this study shows that identification of BO in a forensic setting is possible and has limits and characteristics in line with witness identification through other sensory modalities. PMID:27303317

  10. System for tamper identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bobbitt, III, John Thomas; Weeks, George E.

    2017-09-05

    A system for tamper identification. A fastener has a tamper identification surface with a unique grain structure that is altered if the fastener is removed or otherwise exposed to sufficient torque. After a period of time such as e.g., shipment and/or storage of the sealed container, a determination of whether tampering has occurred can be undertaken by examining the grain structure to determine if it has changed since the fastener was used to seal the container or secure the device.

  11. Thermodynamic Analysis of TEG-TEC Device Including Influence of Thomson Effect

    NASA Astrophysics Data System (ADS)

    Feng, Yuanli; Chen, Lingen; Meng, Fankai; Sun, Fengrui

    2018-01-01

    A thermodynamic model of a thermoelectric cooler driven by thermoelectric generator (TEG-TEC) device is established considering Thomson effect. The performance is analyzed and optimized using numerical calculation based on non-equilibrium thermodynamic theory. The influence characteristics of Thomson effect on the optimal performance and variable selection are investigated by comparing the condition with and without Thomson effect. The results show that Thomson effect degrades the performance of TEG-TEC device, it decreases the cooling capacity by 27 %, decreases the coefficient of performance (COP) by 19 %, decreases the maximum cooling temperature difference by 11 % when the ratio of thermoelectric elements number is 0.6, the cold junction temperature of thermoelectric cooler (TEC) is 285 K and the hot junction temperature of thermoelectric generator (TEG) is 450 K. Thomson effect degrades the optimal performance of TEG-TEC device, it decreases the maximum cooling capacity by 28 % and decreases the maximum COP by 28 % under the same junction temperatures. Thomson effect narrows the optimal variable range and optimal working range. In the design of the devices, limited-number thermoelectric elements should be more allocated appropriately to TEG when consider Thomson effect. The results may provide some guidelines for the design of TEG-TEC devices.

  12. Single-Event Effects in Silicon and Silicon Carbide Power Devices

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.

    2014-01-01

    NASA Electronics Parts and Packaging program-funded activities over the past year on single-event effects in silicon and silicon carbide power devices are presented, with focus on SiC device failure signatures.

  13. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  14. Effects of a continuous lateral turning device on pressure relief.

    PubMed

    Do, Nam Ho; Kim, Deog Young; Kim, Jung-Hoon; Choi, Jong Hyun; Joo, So Young; Kang, Na Kyung; Baek, Yoon Su

    2016-01-01

    [Purpose] The purpose of this study was to examine the pressure-relieving effects of a continuous lateral turning device on common pressure ulcer sites. [Subjects] Twenty-four healthy adults participated. [Methods] The design of our continuous lateral turning device was motivated by the need for an adequate pressure-relieving device for immobile and/or elderly people. The procedure of manual repositioning is embodied in our continuous lateral turning device. The interface pressure and time were measured, and comfort grade was evaluated during sessions of continuous lateral turning at 0°, 15°, 30°, and 45°. We quantified the pressure-relieving effect using peak pressure, mean pressure, and pressure time integration. [Results] Participants demonstrated pressure time integration values below the pressure-time threshold at 15°, 30°, and 45° at all the common pressure ulcer sites. Moreover, the most effective angles for pressure relief at the common pressure ulcer sites were 30° at the occiput, 15° at the left scapula, 45° at the right scapula, 45° at the sacrum, 15° at the right heel, and 30° at the left heel. However, angles greater than 30° induced discomfort. [Conclusion] Continuous lateral turning with our specially designed device effectively relieved the pressure of targeted sites. Moreover, the suggested angles of continuous lateral turning can be used to relieve pressure at targeted sites.

  15. Lineup identification by children: effects of clothing bias.

    PubMed

    Freire, Alejo; Lee, Kang; Williamson, Karen S; Stuart, Sarah J E; Lindsay, R C L

    2004-06-01

    This study examined effects of clothing cues on children's identification accuracy from lineups. Four- to 14-year-olds (n = 228) saw 12 video clips of individuals, each wearing a distinctly colored shirt. After watching each clip children were presented with a target-present or target-absent photo lineup. Three clothing conditions were included. In 2 conditions all lineup members wore the same colored shirt; in the third, biased condition, the shirt color of only one individual matched that seen in the preceding clip (the target in target-present trials and the replacement in target-absent trials). Correct identifications of the target in target-present trials were most frequent in the biased condition, whereas in target-absent trials the biased condition led to more false identifications of the target replacement. Older children were more accurate than younger children, both in choosing the target from target-present lineups and rejecting target-absent lineups. These findings suggest that a simple clothing cue such as shirt color can have a significant impact on children's lineup identification accuracy.

  16. Lineup Identification by Children: Effects of Clothing Bias

    PubMed Central

    Freire, Alejo; Lee, Kang; Williamson, Karen S.; Stuart, Sarah J. E.; Lindsay, R. C. L.

    2008-01-01

    This study examined effects of clothing cues on children's identification accuracy from lineups. Four- to 14-year-olds (n = 228) saw 12 video clips of individuals, each wearing a distinctly colored shirt. After watching each clip children were presented with a target-present or target-absent photo lineup. Three clothing conditions were included. In 2 conditions all lineup members wore the same colored shirt; in the third, biased condition, the shirt color of only one individual matched that seen in the preceding clip (the target in target-present trials and the replacement in target-absent trials). Correct identifications of the target in target-present trials were most frequent in the biased condition, whereas in target-absent trials the biased condition led to more false identifications of the target replacement. Older children were more accurate than younger children, both in choosing the target from target-present lineups and rejecting target-absent lineups. These findings suggest that a simple clothing cue such as shirt color can have a significant impact on children's lineup identification accuracy. PMID:15264450

  17. Face identification with frequency domain matched filtering in mobile environments

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Su; Woo, Yong-Hyun; Yeom, Seokwon; Kim, Shin-Hwan

    2012-06-01

    Face identification at a distance is very challenging since captured images are often degraded by blur and noise. Furthermore, the computational resources and memory are often limited in the mobile environments. Thus, it is very challenging to develop a real-time face identification system on the mobile device. This paper discusses face identification based on frequency domain matched filtering in the mobile environments. Face identification is performed by the linear or phase-only matched filter and sequential verification stages. The candidate window regions are decided by the major peaks of the linear or phase-only matched filtering outputs. The sequential stages comprise a skin-color test and an edge mask filtering test, which verify color and shape information of the candidate regions in order to remove false alarms. All algorithms are built on the mobile device using Android platform. The preliminary results show that face identification of East Asian people can be performed successfully in the mobile environments.

  18. Radiation Effects On Emerging Electronic Materials And Devices

    DTIC Science & Technology

    2010-01-17

    RADIATION EFFECTS ON EMERGING ELECTRONIC MATERIALS AND DEVICES FINAL PERFORMANCE REPORT PREPARED FOR: Kitt Reinhardt AFOSR/NE 875 N...and the other with metal gates and a high-K gate dielectric. These devices were programmed using both back-gate pulse and gate induced drain leakage... metal gate process GIDL method Fig. 1. Sensing margin as a function of total ionizing dose for nMOS 1T-DRAM cells programmed by back-gate pulse and

  19. Distinguishing institutional identification from academic goal pursuit: interactive effects of ethnic identification and race-based rejection sensitivity.

    PubMed

    Mendoza-Denton, Rodolfo; Pietrzak, Janina; Downey, Geraldine

    2008-08-01

    We examined the interactive effects of ethnic identification (EI) and race-based rejection sensitivity (RS-race) on institutional outcomes among African American college students. We distinguished between effects on institutional identification on the one hand and academic goal pursuit (e.g., staying in school, grade point average [GPA]) on the other. Supporting the utility of this distinction, we found that EI and RS-race interacted to predict these outcomes differently. Higher EI in combination with higher RS-race predicted reduced identification with the institution (Studies 1, 2, and 3a). This combination, however, did not lead to decreases in GPA over time. Moreover, EI was positively related to intentions to stay in school as well as to GPA increases among those lower in RS-race (Studies 1 and 3b). Implications for understanding identity negotiation vis-à-vis performance in institutional settings are discussed. (c) 2008 APA, all rights reserved

  20. Model identification methodology for fluid-based inerters

    NASA Astrophysics Data System (ADS)

    Liu, Xiaofu; Jiang, Jason Zheng; Titurus, Branislav; Harrison, Andrew

    2018-06-01

    Inerter is the mechanical dual of the capacitor via the force-current analogy. It has the property that the force across the terminals is proportional to their relative acceleration. Compared with flywheel-based inerters, fluid-based forms have advantages of improved durability, inherent damping and simplicity of design. In order to improve the understanding of the physical behaviour of this fluid-based device, especially caused by the hydraulic resistance and inertial effects in the external tube, this work proposes a comprehensive model identification methodology. Firstly, a modelling procedure is established, which allows the topological arrangement of the mechanical networks to be obtained by mapping the damping, inertance and stiffness effects directly to their respective hydraulic counterparts. Secondly, an experimental sequence is followed, which separates the identification of friction, stiffness and various damping effects. Furthermore, an experimental set-up is introduced, where two pressure gauges are used to accurately measure the pressure drop across the external tube. The theoretical models with improved confidence are obtained using the proposed methodology for a helical-tube fluid inerter prototype. The sources of remaining discrepancies are further analysed.

  1. Zero-Power Radio Device.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brocato, Robert W.

    This report describes an unpowered radio receiver capable of detecting and responding to weak signals transmit ted from comparatively long distances . This radio receiver offers key advantages over a short range zero - power radio receiver previously described in SAND2004 - 4610, A Zero - Power Radio Receiver . The device described here can be fabricated as an integrated circuit for use in portable wireless devices, as a wake - up circuit, or a s a stand - alone receiver operating in conjunction with identification decoders or other electroni cs. It builds on key sub - components developed atmore » Sandia National Laboratories over many years. It uses surface acoustic wave (SAW) filter technology. It uses custom component design to enable the efficient use of small aperture antennas. This device uses a key component, the pyroelectric demodulator , covered by Sandia owned U.S. Patent 7397301, Pyroelectric Demodulating Detector [1] . This device is also described in Sandia owned U.S. Patent 97266446, Zero Power Receiver [2].« less

  2. Effect of Enrichment Devices on Aggression in Manipulated Nude Mice.

    PubMed

    Lockworth, Cynthia R; Kim, Sun-Jin; Liu, Jun; Palla, Shana L; Craig, Suzanne L

    2015-11-01

    Agonistic behavior in group-housed male mice is a recurring problem in many animal research facilities. Common management procedures, such as the removal of aggressors, are moderately successful but often fail, owing to recurrence of aggressive behavior among cagemates. Studies have incorporated enrichment devices to attenuate aggression, but such devices have had mixed results. However, these studies did not include research manipulations when assessing the benefits of various enrichment devices. We obtained 100 male athymic nude mice and studied the efficacy of various enrichment devices, including cotton squares, paper rolls, shredded paper, nylon bones, and a mouse house and wheel combination in the reduction of fighting during an ongoing study that involved randomization followed by prostate and intratibial injections. Groups were evaluated according to a numerical grading system for wound assessment. Examination of the data revealed that the enrichment devices had no effect on the presence of wounds, thus none of the devices tested affected fighting in nude mice. However, when mice began experimental use, fight wounds increased significantly at cage change and after randomization, reflecting a disruption of existing social hierarchies. Therefore, in the context of an actual research study that involves common manipulations, the specific enrichment device had less effect on aggression in male nude mice than did the destruction and reconstruction of social structures within each group.

  3. Highly air stable passivation of graphene based field effect devices.

    PubMed

    Sagade, Abhay A; Neumaier, Daniel; Schall, Daniel; Otto, Martin; Pesquera, Amaia; Centeno, Alba; Elorza, Amaia Zurutuza; Kurz, Heinrich

    2015-02-28

    The sensitivity of graphene based devices to surface adsorbates and charge traps at the graphene/dielectric interface requires proper device passivation in order to operate them reproducibly under ambient conditions. Here we report on the use of atomic layer deposited aluminum oxide as passivation layer on graphene field effect devices (GFETs). We show that successful passivation produce hysteresis free DC characteristics, low doping level GFETs stable over weeks though operated and stored in ambient atmosphere. This is achieved by selecting proper seed layer prior to deposition of encapsulation layer. The passivated devices are also demonstrated to be robust towards the exposure to chemicals and heat treatments, typically used during device fabrication. Additionally, the passivation of high stability and reproducible characteristics is also shown for functional devices like integrated graphene based inverters.

  4. Fentanyl Iontophoretic Transdermal System (IONSYS(®)) can be Safely used in the Hospital Environment with X-Rays, Computerized Tomography and Radiofrequency Identification Devices.

    PubMed

    Lemke, John; Sardariani, Edmond; Phipps, Joseph Bradley; Patel, Niki; Itri, Loretta M; Caravelli, James; Viscusi, Eugene R

    2016-09-01

    Fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS(®)) is a patient-controlled analgesia system used for the management of acute postoperative pain, designed to be utilized in a hospital setting. The objective of the two studies was to determine if fentanyl ITS could be safely used with X-rays, computerized tomography (CT) scans and radiofrequency identification (RFID) devices. The ITS system has two components: controller and drug unit; the studies utilized ITS systems without fentanyl, referred to as the ITS Placebo system. The first study evaluated the effect of X-radiation on the operation of an ITS Placebo system. Five ITS Placebo systems were exposed to X-rays (20 and 200 mSv total radiation dose-the 200 mSv radiation dose represents a tenfold higher exposure than in clinical practice) while operating in the Ready Mode and five were exposed while operating in the Dose Mode. The second study evaluated the effect of RFID (worst-case scenario of direct contact with an RFID transmitter) on the operation of an ITS Placebo system. During these tests, observations of the user interface and measurements of output voltage confirmed proper function throughout all operational modes (Ready Mode, Dose Mode, End-of-Use Mode, and End-of-Life Mode). The ITS Placebo system met all specifications and no functional anomalies were observed during and following X-ray exposure at two radiation dose levels or exposure at six different combinations of RFID frequencies and field strengths. The performance of the ITS system was unaffected by X-ray exposure levels well beyond those associated with diagnostic X-rays and CT scans, and by exposure to radiofrequency field strengths typically generated by RFID devices. These results provide added confidence to clinicians that the fentanyl ITS system does not need to be removed during diagnostic X-rays and CT scans and can also be utilized in close proximity to RFID devices. The studies and writing of this manuscript were

  5. Studies to determine the effectiveness of automated flagger assistance devices and school crossing devices.

    DOT National Transportation Integrated Search

    2012-01-01

    This report describes the methodology and results of analyses performed to determine motorist understanding, as well as : the operational and safety effectiveness, of automated flagger assistance devices (AFADs) relative to the use of flaggers at lan...

  6. Effects of postidentification feedback on eyewitness identification and nonidentification confidence.

    PubMed

    Semmler, Carolyn; Brewer, Neil; Wells, Gary L

    2004-04-01

    Two experiments investigated new dimensions of the effect of confirming feedback on eyewitness identification confidence using target-absent and target-present lineups and (previously unused) unbiased witness instructions (i.e., "offender not present" option highlighted). In Experiment 1, participants viewed a crime video and were later asked to try to identify the thief from an 8-person target-absent photo array. Feedback inflated witness confidence for both mistaken identifications and correct lineup rejections. With target-present lineups in Experiment 2, feedback inflated confidence for correct and mistaken identifications and lineup rejections. Although feedback had no influence on the confidence-accuracy correlation, it produced clear overconfidence. Confidence inflation varied with the confidence measure reference point (i.e., retrospective vs. current confidence) and identification response latency.

  7. 9 CFR 79.2 - Identification of sheep and goats in interstate commerce.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... prefix that has been linked in the National Scrapie Database with the assigned premises identification... official identification method or device approved by the Administrator. (3) The owner of the flock of... premises identification if they are linked to the premises in the National Scrapie Database) will be...

  8. 9 CFR 79.2 - Identification of sheep and goats in interstate commerce.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... prefix that has been linked in the National Scrapie Database with the assigned premises identification... official identification method or device approved by the Administrator. (3) The owner of the flock of... premises identification if they are linked to the premises in the National Scrapie Database) will be...

  9. 9 CFR 79.2 - Identification of sheep and goats in interstate commerce.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... prefix that has been linked in the National Scrapie Database with the assigned premises identification... official identification method or device approved by the Administrator. (3) The owner of the flock of... premises identification if they are linked to the premises in the National Scrapie Database) will be...

  10. Apparatus for and method of testing an electrical ground fault circuit interrupt device

    DOEpatents

    Andrews, L.B.

    1998-08-18

    An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined. 17 figs.

  11. Apparatus for and method of testing an electrical ground fault circuit interrupt device

    DOEpatents

    Andrews, Lowell B.

    1998-01-01

    An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined.

  12. Hafnia-based resistive switching devices for non-volatile memory applications and effects of gamma irradiation on device performance

    NASA Astrophysics Data System (ADS)

    Arun, N.; Kumar, K. Vinod; Pathak, A. P.; Avasthi, D. K.; Nageswara Rao, S. V. S.

    2018-04-01

    Non-volatile memory (NVM) devices were fabricated as a Metal- Insulator-Metal (MIM) structures by sandwiching Hafnium dioxide (HfO2) thin film in between two metal electrodes. The top and bottom metal electrodes were deposited by using the thermal evaporation, and the oxide layer was deposited by using the RF magnetron sputtering technique. The Resistive Random Access Memory (RRAM) device structures such as Ag/HfO2/Au/Si were fabricated and I-V characteristics for the pristine and gamma-irradiated devices with a dose 24 kGy were measured. Further we have studied the thermal annealing effects, in the range of 100°-400°C in a tubular furnace for the HfO2/Au/Si samples. The X-ray diffraction (XRD), Rutherford Backscattering Spectrometry (RBS), field emission-scanning electron microscopy (FESEM) analysis measurements were performed to determine the thickness, crystallinity and stoichiometry of these films. The electrical characteristics such as resistive switching, endurance, retention time and switching speed were measured by a semiconductor device analyser. The effects of gamma irradiation on the switching properties of these RRAM devices have been studied.

  13. Effects of mobile phone use on specific intensive care unit devices.

    PubMed

    Hans, Nidhi; Kapadia, Farhad N

    2008-10-01

    To observe the effects of mobile phone use in the vicinity of medical devices used in a critical care setting. Electromagnetic interference (EMI) was tested by using two types of mobile phones - GSM and CDMA. Mobile phones were placed at a distance of one foot from three medical devices - syringe pump, mechanical ventilator, and the bedside monitor - in switch off, standby, and talking modes of the phone. Medical devices were observed for any interference caused by the electromagnetic radiations (EMR) from the mobile phones. Out of the three medical devices that were tested, EMI occurred while using the mobile phone in the vicinity of the syringe pump, in the 'talk mode.' The mean variation observed in the calculated and delivered volume of the syringe pump was 2.66 ml. Mechanical ventilator did not show any specific adverse effects with mobile phone use in the one-foot vicinity. No other adverse effects or unexplained malfunctions or shutdown of the syringe pump, mechanical ventilator, or the bedside monitor was noted during the study period of 36 hours. EMI from mobile phones have an adverse effect on the medical devices used in critical care setup. They should be used at least one foot away from the diameter of the syringe pump.

  14. On the security of consumer wearable devices in the Internet of Things.

    PubMed

    Tahir, Hasan; Tahir, Ruhma; McDonald-Maier, Klaus

    2018-01-01

    Miniaturization of computer hardware and the demand for network capable devices has resulted in the emergence of a new class of technology called wearable computing. Wearable devices have many purposes like lifestyle support, health monitoring, fitness monitoring, entertainment, industrial uses, and gaming. Wearable devices are hurriedly being marketed in an attempt to capture an emerging market. Owing to this, some devices do not adequately address the need for security. To enable virtualization and connectivity wearable devices sense and transmit data, therefore it is essential that the device, its data and the user are protected. In this paper the use of novel Integrated Circuit Metric (ICMetric) technology for the provision of security in wearable devices has been suggested. ICMetric technology uses the features of a device to generate an identification which is then used for the provision of cryptographic services. This paper explores how a device ICMetric can be generated by using the accelerometer and gyroscope sensor. Since wearable devices often operate in a group setting the work also focuses on generating a group identification which is then used to deliver services like authentication, confidentiality, secure admission and symmetric key generation. Experiment and simulation results prove that the scheme offers high levels of security without compromising on resource demands.

  15. On the security of consumer wearable devices in the Internet of Things

    PubMed Central

    Tahir, Hasan; Tahir, Ruhma; McDonald-Maier, Klaus

    2018-01-01

    Miniaturization of computer hardware and the demand for network capable devices has resulted in the emergence of a new class of technology called wearable computing. Wearable devices have many purposes like lifestyle support, health monitoring, fitness monitoring, entertainment, industrial uses, and gaming. Wearable devices are hurriedly being marketed in an attempt to capture an emerging market. Owing to this, some devices do not adequately address the need for security. To enable virtualization and connectivity wearable devices sense and transmit data, therefore it is essential that the device, its data and the user are protected. In this paper the use of novel Integrated Circuit Metric (ICMetric) technology for the provision of security in wearable devices has been suggested. ICMetric technology uses the features of a device to generate an identification which is then used for the provision of cryptographic services. This paper explores how a device ICMetric can be generated by using the accelerometer and gyroscope sensor. Since wearable devices often operate in a group setting the work also focuses on generating a group identification which is then used to deliver services like authentication, confidentiality, secure admission and symmetric key generation. Experiment and simulation results prove that the scheme offers high levels of security without compromising on resource demands. PMID:29668756

  16. Piezo Voltage Controlled Planar Hall Effect Devices

    PubMed Central

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K. W.; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-01-01

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials. PMID:27329068

  17. Piezo Voltage Controlled Planar Hall Effect Devices.

    PubMed

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  18. Identification with the retail organization and customer-perceived employee similarity: effects on customer spending.

    PubMed

    Netemeyer, Richard G; Heilman, Carrie M; Maxham, James G

    2012-09-01

    Two constructs important to academicians and managers are the degree to which employees and customers identify with an organization, employee organizational identification (employee OI) and customer-company identification (customer identification), respectively. This research examines the effects of these identification constructs and the related construct of customer perceived similarity to employees on customer spending. Via a 1-year multilevel study of 12,047 customers and 1,464 store employees (sales associates) covering 212 stores of a specialty apparel retailer, our study contributes to the literature in 2 critical ways. First, we expand the theoretical network of employee OI and customer identification by examining the related construct of a customer's perceived similarity to store employees. We examine the incremental (not fully mediated) main and interaction effects of customer-perceived similarity to employees and employee OI on customer spending. Second, we examine the effect of customer identification on customer spending relative to the effect of customer satisfaction on customer spending. Thus, our study also contributes by demonstrating a potential complementary route to achieve customer spending (customer identification), a route that may be more readily affected by management than the efforts required for a sustained increase in customer satisfaction. Implications for academics and managers are offered.

  19. Identification as a Mediator of Celebrity Effects.

    ERIC Educational Resources Information Center

    Basil, Michael D.

    1996-01-01

    This study examined personal concern, perceived risk, and sexual behavior of 147 college students a year after Magic Johnson announced he tested positive for HIV (Human Immunodeficiency Virus). It found that identification mediates message effects, suggesting that a spokesperson with whom an audience can identify insures the greatest likelihood of…

  20. Effects of Device on Video Head Impulse Test (vHIT) Gain.

    PubMed

    Janky, Kristen L; Patterson, Jessie N; Shepard, Neil T; Thomas, Megan L A; Honaker, Julie A

    2017-10-01

    Numerous video head impulse test (vHIT) devices are available commercially; however, gain is not calculated uniformly. An evaluation of these devices/algorithms in healthy controls and patients with vestibular loss is necessary for comparing and synthesizing work that utilizes different devices and gain calculations. Using three commercially available vHIT devices/algorithms, the purpose of the present study was to compare: (1) horizontal canal vHIT gain among devices/algorithms in normal control subjects; (2) the effects of age on vHIT gain for each device/algorithm in normal control subjects; and (3) the clinical performance of horizontal canal vHIT gain between devices/algorithms for differentiating normal versus abnormal vestibular function. Prospective. Sixty-one normal control adult subjects (range 20-78) and eleven adults with unilateral or bilateral vestibular loss (range 32-79). vHIT was administered using three different devices/algorithms, randomized in order, for each subject on the same day: (1) Impulse (Otometrics, Schaumberg, IL; monocular eye recording, right eye only; using area under the curve gain), (2) EyeSeeCam (Interacoustics, Denmark; monocular eye recording, left eye only; using instantaneous gain), and (3) VisualEyes (MicroMedical, Chatham, IL, binocular eye recording; using position gain). There was a significant mean difference in vHIT gain among devices/algorithms for both the normal control and vestibular loss groups. vHIT gain was significantly larger in the ipsilateral direction of the eye used to measure gain; however, in spite of the significant mean differences in vHIT gain among devices/algorithms and the significant directional bias, classification of "normal" versus "abnormal" gain is consistent across all compared devices/algorithms, with the exception of instantaneous gain at 40 msec. There was not an effect of age on vHIT gain up to 78 years regardless of the device/algorithm. These findings support that vHIT gain is

  1. Framework for automatic information extraction from research papers on nanocrystal devices

    PubMed Central

    Yoshioka, Masaharu; Hara, Shinjiro; Newton, Marcus C

    2015-01-01

    Summary To support nanocrystal device development, we have been working on a computational framework to utilize information in research papers on nanocrystal devices. We developed an annotated corpus called “ NaDev” (Nanocrystal Device Development) for this purpose. We also proposed an automatic information extraction system called “NaDevEx” (Nanocrystal Device Automatic Information Extraction Framework). NaDevEx aims at extracting information from research papers on nanocrystal devices using the NaDev corpus and machine-learning techniques. However, the characteristics of NaDevEx were not examined in detail. In this paper, we conduct system evaluation experiments for NaDevEx using the NaDev corpus. We discuss three main issues: system performance, compared with human annotators; the effect of paper type (synthesis or characterization) on system performance; and the effects of domain knowledge features (e.g., a chemical named entity recognition system and list of names of physical quantities) on system performance. We found that overall system performance was 89% in precision and 69% in recall. If we consider identification of terms that intersect with correct terms for the same information category as the correct identification, i.e., loose agreement (in many cases, we can find that appropriate head nouns such as temperature or pressure loosely match between two terms), the overall performance is 95% in precision and 74% in recall. The system performance is almost comparable with results of human annotators for information categories with rich domain knowledge information (source material). However, for other information categories, given the relatively large number of terms that exist only in one paper, recall of individual information categories is not high (39–73%); however, precision is better (75–97%). The average performance for synthesis papers is better than that for characterization papers because of the lack of training examples for

  2. Framework for automatic information extraction from research papers on nanocrystal devices.

    PubMed

    Dieb, Thaer M; Yoshioka, Masaharu; Hara, Shinjiro; Newton, Marcus C

    2015-01-01

    To support nanocrystal device development, we have been working on a computational framework to utilize information in research papers on nanocrystal devices. We developed an annotated corpus called " NaDev" (Nanocrystal Device Development) for this purpose. We also proposed an automatic information extraction system called "NaDevEx" (Nanocrystal Device Automatic Information Extraction Framework). NaDevEx aims at extracting information from research papers on nanocrystal devices using the NaDev corpus and machine-learning techniques. However, the characteristics of NaDevEx were not examined in detail. In this paper, we conduct system evaluation experiments for NaDevEx using the NaDev corpus. We discuss three main issues: system performance, compared with human annotators; the effect of paper type (synthesis or characterization) on system performance; and the effects of domain knowledge features (e.g., a chemical named entity recognition system and list of names of physical quantities) on system performance. We found that overall system performance was 89% in precision and 69% in recall. If we consider identification of terms that intersect with correct terms for the same information category as the correct identification, i.e., loose agreement (in many cases, we can find that appropriate head nouns such as temperature or pressure loosely match between two terms), the overall performance is 95% in precision and 74% in recall. The system performance is almost comparable with results of human annotators for information categories with rich domain knowledge information (source material). However, for other information categories, given the relatively large number of terms that exist only in one paper, recall of individual information categories is not high (39-73%); however, precision is better (75-97%). The average performance for synthesis papers is better than that for characterization papers because of the lack of training examples for characterization papers

  3. Effects of hydraulic pressure on cardiomyoblasts in a microfluidic device.

    PubMed

    Hsiao, Yu-Fang; Pan, Huei-Jyuan; Tung, Yi-Chung; Chen, Chien-Chang; Lee, Chau-Hwang

    2015-03-01

    We employed a microfluidic device to study the effects of hydraulic pressure on cardiomyoblast H9c2. The 170 mm Hg pressure increased the cellular area and the expression of atrial natriuretic peptide. With the same device, we demonstrated that the effects of hydraulic pressure on the cardiomyoblast could be reduced by the inhibitor of focal adhesion kinase. This mechanical-chemical antagonism could lead to a potential therapeutic strategy of hypertension-induced cardiac hypertrophy.

  4. Visual Presentation Effects on Identification of Multiple Environmental Sounds

    PubMed Central

    Masakura, Yuko; Ichikawa, Makoto; Shimono, Koichi; Nakatsuka, Reio

    2016-01-01

    This study examined how the contents and timing of a visual stimulus affect the identification of mixed sounds recorded in a daily life environment. For experiments, we presented four environment sounds as auditory stimuli for 5 s along with a picture or a written word as a visual stimulus that might or might not denote the source of one of the four sounds. Three conditions of temporal relations between the visual stimuli and sounds were used. The visual stimulus was presented either: (a) for 5 s simultaneously with the sound; (b) for 5 s, 1 s before the sound (SOA between the audio and visual stimuli was 6 s); or (c) for 33 ms, 1 s before the sound (SOA was 1033 ms). Participants reported all identifiable sounds for those audio–visual stimuli. To characterize the effects of visual stimuli on sound identification, the following were used: the identification rates of sounds for which the visual stimulus denoted its sound source, the rates of other sounds for which the visual stimulus did not denote the sound source, and the frequency of false hearing of a sound that was not presented for each sound set. Results of the four experiments demonstrated that a picture or a written word promoted identification of the sound when it was related to the sound, particularly when the visual stimulus was presented for 5 s simultaneously with the sounds. However, a visual stimulus preceding the sounds had a benefit only for the picture, not for the written word. Furthermore, presentation with a picture denoting a sound simultaneously with the sound reduced the frequency of false hearing. These results suggest three ways that presenting a visual stimulus affects identification of the auditory stimulus. First, activation of the visual representation extracted directly from the picture promotes identification of the denoted sound and suppresses the processing of sounds for which the visual stimulus did not denote the sound source. Second, effects based on processing of the

  5. Flow visualization of a non-contact transport device by Coanda effect

    NASA Astrophysics Data System (ADS)

    Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi

    2014-08-01

    AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.

  6. A generic approach for examining the effectiveness of traffic control devices in school zones.

    PubMed

    Zhao, Xiaohua; Li, Jiahui; Ding, Han; Zhang, Guohui; Rong, Jian

    2015-09-01

    The effectiveness and performance of traffic control devices in school zones have been impacted significantly by many factors, such as driver behavioral attributes, roadway geometric features, environmental characteristics, weather and visibility conditions, region-wide traffic regulations and policies, control modes, etc. When deploying traffic control devices in school zones, efforts are needed to clarify: (1) whether traffic control device installation is warranted; and (2) whether other device effectively complements this traffic control device and strengthens its effectiveness. In this study, a generic approach is developed to examine and evaluate the effectiveness of various traffic control devices deployed in school zones through driving simulator-based experiments. A Traffic Control Device Selection Model (TCDSM) is developed and two representative school zones are selected as the testbed in Beijing for driving simulation implementation to enhance its applicability. Statistical analyses are conducted to extract the knowledge from test data recorded by a driving simulator. Multiple measures of effectiveness (MOEs) are developed and adopted including average speed, relative speed difference, and standard deviation of acceleration for traffic control device performance quantification. The experimental tests and analysis results reveal that the appropriateness of the installation of certain traffic control devices can be statistically verified by TCDSM. The proposed approach provides a generic framework to assess traffic control device performance in school zones including experiment design, statistical formulation, data analysis, simulation model implementation, data interpretation, and recommendation development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking

    PubMed Central

    Juliano, Laura M.

    2016-01-01

    Abstract Background: Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker’s mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Methods: Smokers ( N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Results: Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. Conclusions: The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. Implications: When considering the inclusion of a smoking topography device in one’s research, it is important to know if use of that device will alter the smoker’s experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic

  8. Magnetic field effects in hybrid perovskite devices

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Sun, D.; Sheng, C.-X.; Zhai, Y. X.; Mielczarek, K.; Zakhidov, A.; Vardeny, Z. V.

    2015-05-01

    Magnetic field effects have been a successful tool for studying carrier dynamics in organic semiconductors as the weak spin-orbit coupling in these materials gives rise to long spin relaxation times. As the spin-orbit coupling is strong in organic-inorganic hybrid perovskites, which are promising materials for photovoltaic and light-emitting applications, magnetic field effects are expected to be negligible in these optoelectronic devices. We measured significant magneto-photocurrent, magneto-electroluminescence and magneto-photoluminescence responses in hybrid perovskite devices and thin films, where the amplitude and shape are correlated to each other through the electron-hole lifetime, which depends on the perovskite film morphology. We attribute these responses to magnetic-field-induced spin-mixing of the photogenerated electron-hole pairs with different g-factors--the Δg model. We validate this model by measuring large Δg (~ 0.65) using field-induced circularly polarized photoluminescence, and electron-hole pair lifetime using picosecond pump-probe spectroscopy.

  9. Effectiveness of Mobile Devices on Vocabulary Learning: A Meta-Analysis

    ERIC Educational Resources Information Center

    Mahdi, Hassan Saleh

    2018-01-01

    Mobile devices are considered as the most widely used information and communication technologies. They have provided great advantages in language learning. This study reports a meta-analysis of the effectiveness of using mobile devices on vocabulary learning. A meta-analysis was conducted on research that compared the outcomes from students…

  10. 21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-Powered suction apparatus device intended for... Surgical Devices § 878.4683 Non-Powered suction apparatus device intended for negative pressure wound therapy. (a) Identification. A non-powered suction apparatus device intended for negative pressure wound...

  11. High-accuracy user identification using EEG biometrics.

    PubMed

    Koike-Akino, Toshiaki; Mahajan, Ruhi; Marks, Tim K; Ye Wang; Watanabe, Shinji; Tuzel, Oncel; Orlik, Philip

    2016-08-01

    We analyze brain waves acquired through a consumer-grade EEG device to investigate its capabilities for user identification and authentication. First, we show the statistical significance of the P300 component in event-related potential (ERP) data from 14-channel EEGs across 25 subjects. We then apply a variety of machine learning techniques, comparing the user identification performance of various different combinations of a dimensionality reduction technique followed by a classification algorithm. Experimental results show that an identification accuracy of 72% can be achieved using only a single 800 ms ERP epoch. In addition, we demonstrate that the user identification accuracy can be significantly improved to more than 96.7% by joint classification of multiple epochs.

  12. A Improved and Highly Effective Seabed Surface Sand Sampling Device

    NASA Astrophysics Data System (ADS)

    Liu, Ying

    2017-04-01

    In marine geology research, it is necessary to obtain a sufficient quantity of seabed surface samples, while also ensuring that the samples are in their original state. Currently, there are a number of seabed surface sampling devices available, but it is very difficult to obtain sand samples using ordinary seabed surface sampling devices, whereas machine-controlled seabed surface sampling devices are unable to dive into deeper regions of water. To obtain larger quantities of samples in their original states, many researchers have tried to improve seabed surface sampling devices, but these efforts have generally produced ambiguous results. To resolve the aforementioned issue, we have designed an improved and highly effective seabed surface sand sampling device, which incorporates the strengths of a variety of sampling devices; it is capable of diving into deeper water regions to obtain sand samples, and is also suited for use in streams, rivers, lakes and seas with varying levels of flow velocities and depth.

  13. Event identification by acoustic signature recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dress, W.B.; Kercel, S.W.

    1995-07-01

    Many events of interest to the security commnnity produce acoustic emissions that are, in principle, identifiable as to cause. Some obvious examples are gunshots, breaking glass, takeoffs and landings of small aircraft, vehicular engine noises, footsteps (high frequencies when on gravel, very low frequencies. when on soil), and voices (whispers to shouts). We are investigating wavelet-based methods to extract unique features of such events for classification and identification. We also discuss methods of classification and pattern recognition specifically tailored for acoustic signatures obtained by wavelet analysis. The paper is divided into three parts: completed work, work in progress, and futuremore » applications. The completed phase has led to the successful recognition of aircraft types on landing and takeoff. Both small aircraft (twin-engine turboprop) and large (commercial airliners) were included in the study. The project considered the design of a small, field-deployable, inexpensive device. The techniques developed during the aircraft identification phase were then adapted to a multispectral electromagnetic interference monitoring device now deployed in a nuclear power plant. This is a general-purpose wavelet analysis engine, spanning 14 octaves, and can be adapted for other specific tasks. Work in progress is focused on applying the methods previously developed to speaker identification. Some of the problems to be overcome include recognition of sounds as voice patterns and as distinct from possible background noises (e.g., music), as well as identification of the speaker from a short-duration voice sample. A generalization of the completed work and the work in progress is a device capable of classifying any number of acoustic events-particularly quasi-stationary events such as engine noises and voices and singular events such as gunshots and breaking glass. We will show examples of both kinds of events and discuss their recognition likelihood.« less

  14. Methodological considerations in observational comparative effectiveness research for implantable medical devices: an epidemiologic perspective.

    PubMed

    Jalbert, Jessica J; Ritchey, Mary Elizabeth; Mi, Xiaojuan; Chen, Chih-Ying; Hammill, Bradley G; Curtis, Lesley H; Setoguchi, Soko

    2014-11-01

    Medical devices play a vital role in diagnosing, treating, and preventing diseases and are an integral part of the health-care system. Many devices, including implantable medical devices, enter the market through a regulatory pathway that was not designed to assure safety and effectiveness. Several recent studies and high-profile device recalls have demonstrated the need for well-designed, valid postmarketing studies of medical devices. Medical device epidemiology is a relatively new field compared with pharmacoepidemiology, which for decades has been developed to assess the safety and effectiveness of medications. Many methodological considerations in pharmacoepidemiology apply to medical device epidemiology. Fundamental differences in mechanisms of action and use and in how exposure data are captured mean that comparative effectiveness studies of medical devices often necessitate additional and different considerations. In this paper, we discuss some of the most salient issues encountered in conducting comparative effectiveness research on implantable devices. We discuss special methodological considerations regarding the use of data sources, exposure and outcome definitions, timing of exposure, and sources of bias. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Magnetic field effect in organic films and devices

    NASA Astrophysics Data System (ADS)

    Gautam, Bhoj Raj

    In this work, we focused on the magnetic field effect in organic films and devices, including organic light emitting diodes (OLEDs) and organic photovoltaic (OPV) cells. We measured magnetic field effect (MFE) such as magnetoconductance (MC) and magneto-electroluminescence (MEL) in OLEDs based on several pi- conjugated polymers and small molecules for fields |B|<100 mT. We found that both MC(B) and MEL(B) responses in bipolar devices and MC(B) response in unipolar devices are composed of two B-regions: (i) an 'ultra-small' region at |B| < 1-2 mT, and (ii) a monotonic response region at |B| >˜2mT. Magnetic field effect (MFE) measured on three isotopes of Poly (dioctyloxy) phenylenevinylene (DOO-PPV) showed that both regular and ultra-small effects are isotope dependent. This indicates that MFE response in OLED is mainly due to the hyperfine interaction (HFI). We also performed spectroscopy of the MFE including magneto-photoinduced absorption (MPA) and magneto-photoluminescence (MPL) at steady state conditions in several systems. This includes pristine Poly[2-methoxy-5-(2-ethylhexyl-oxy)-1,4-phenylene-vinylene] (MEH-PPV) films, MEH-PPV films subjected to prolonged illumination, and MEH-PPV/[6,6]-Phenyl C61 butyric acid methyl ester (PCBM) blend, as well as annealed and pristine C60 thin films. For comparison, we also measured MC and MEL in organic diodes based on the same materials. By directly comparing the MPA and MPL responses in films to MC and MEL in organic diodes based on the same active layers, we are able to relate the MFE in organic diodes to the spin densities of the excitations formed in the device, regardless of whether they are formed by photon absorption or carrier injection from the electrodes. We also studied magneto-photocurrent (MPC) and power conversion efficiency (PCE) of a 'standard' Poly (3-hexylthiophene)/PCBM device at various Galvinoxyl radical wt%. We found that the MPC reduction with Galvinoxyl wt% follows the same trend as that of the

  16. Radiation effects in materials for optical interferometric devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koumvakalis, N.; Jani, M.G.; Halliburton, L.E.

    The effects of ionizing radiation have been investigated in a series of materials commonly used in optical interferometric devices. Included in the study were three glass-ceramics (Zerodur, Cer-Vit 101, and Cer-Vit 142) and one Faraday-rotator glass (SF-57). Each glass-ceramic was irradiated at room temperature with 1.5-MeV electrons from a Van De Graaff accelerator. Similar irradiations were done on the Faraday-rotator glass at room temperature and 77 K. Optical absorption and electron spin resonance measurements provided a monitor of the radiation-induced point defects in all cases. The spectral characteristics and the production and thermal annealing behavior of these defects are described,more » and their possible effect on the performance of optical devices which incorporate these materials is considered.« less

  17. Buffer Layer Effects on Tandem InGaAs TPV Devices

    NASA Technical Reports Server (NTRS)

    Wilt, David M.; Wehrer, Rebecca J.; Maurer, William F.

    2004-01-01

    configurations both with and without buffer layers. All structures were characterized by reciprocal space x-ray diffraction to determine epilayer composition and residual strain. Electrical characterization of the devices was performed to examine the effect of the buffer on the device performance. The effect of the buffer structure depends upon where it is positioned. When near the emitter region, a 2.6x increase in dark current was measured, whereas no change in dark current was observed when it was near the base region.

  18. Effectiveness of Audible Warning Devices on Emergency Vehicles.

    DOT National Transportation Integrated Search

    1977-08-01

    The purpose of the study was to examine the effectiveness of audible warning devices (AWD's) on emergency vehicles in terms of aural detectability. Community noise intrusion and opportunities for AWD optimization were also investigated. Measurements ...

  19. Total ionizing dose effect in an input/output device for flash memory

    NASA Astrophysics Data System (ADS)

    Liu, Zhang-Li; Hu, Zhi-Yuan; Zhang, Zheng-Xuan; Shao, Hua; Chen, Ming; Bi, Da-Wei; Ning, Bing-Xu; Zou, Shi-Chang

    2011-12-01

    Input/output devices for flash memory are exposed to gamma ray irradiation. Total ionizing dose has been shown great influence on characteristic degradation of transistors with different sizes. In this paper, we observed a larger increase of off-state leakage in the short channel device than in long one. However, a larger threshold voltage shift is observed for the narrow width device than for the wide one, which is well known as the radiation induced narrow channel effect. The radiation induced charge in the shallow trench isolation oxide influences the electric field of the narrow channel device. Also, the drain bias dependence of the off-state leakage after irradiation is observed, which is called the radiation enhanced drain induced barrier lowing effect. Finally, we found that substrate bias voltage can suppress the off-state leakage, while leading to more obvious hump effect.

  20. Piezo-phototronic effect devices

    DOEpatents

    Wang, Zhong L.; Yang, Qing

    2013-09-10

    A semiconducting device includes a piezoelectric structure that has a first end and an opposite second end. A first conductor is in electrical communication with the first end and a second conductor is in electrical communication with the second end so as to form an interface therebetween. A force applying structure is configured to maintain an amount of strain in the piezoelectric member sufficient to generate a desired electrical characteristic in the semiconducting device.

  1. Laser-based irradiation apparatus and methods for monitoring the dose-rate response of semiconductor devices

    DOEpatents

    Horn, Kevin M [Albuquerque, NM

    2006-03-28

    A scanned, pulsed, focused laser irradiation apparatus can measure and image the photocurrent collection resulting from a dose-rate equivalent exposure to infrared laser light across an entire silicon die. Comparisons of dose-rate response images or time-delay images from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems allows precise identification of those specific age-affected circuit structures within a device that merit further quantitative analysis with targeted materials or electrical testing techniques. Another embodiment of the invention comprises a broad-beam, dose rate-equivalent exposure apparatus. The broad-beam laser irradiation apparatus can determine if aging has affected the device's overall functionality. This embodiment can be combined with the synchronized introduction of external electrical transients into a device under test to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure.

  2. [Simplified identification and filter device of carbon dioxide].

    PubMed

    Mei, Xue-qin; Zhang, Yi-ping

    2009-11-01

    This paper presents the design and implementation ways of a simplified device to identify and filter carbon dioxide. The gas went through the test interface which had wet litmus paper before entering the abdominal cavity. Carbon dioxide dissolving in water turned acidic, making litmus paper change color to identify carbon dioxide, in order to avoid malpractice by connecting the wrong gas when making Endoscopic surgery.

  3. Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking.

    PubMed

    Ross, Kathryn C; Juliano, Laura M

    2016-05-01

    Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker's mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Smokers (N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. When considering the inclusion of a smoking topography device in one's research, it is important to know if use of that device will alter the smoker's experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment

  4. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connor, Michael; Wei, Randy L.; Yu, Suhong

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up betweenmore » the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression

  5. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    PubMed

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  6. The effect of vacuum devices on penile hemodynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katz, P.G.; Haden, H.T.; Mulligan, T.

    1990-01-01

    External vacuum devices are being used increasingly for the management of erectile dysfunction. There is limited information regarding the effect of vacuum devices on penile blood flow and potential for ischemic penile injury. The penile xenon washout rate was measured before and after application of 2 vacuum systems in 15 subjects. Compared to flaccid state measurements the xenon washout rate did not change significantly with the Synergist Erection System but it was significantly reduced with the Osbon ErecAid System. However, the degree and duration of decrease in penile blood flow that may result in ischemic changes are unknown.

  7. Particle Capture Devices and Methods of Use Thereof

    NASA Technical Reports Server (NTRS)

    Voldman, Joel (Inventor); Skelley, Alison M. (Inventor); Kirak, Oktay (Inventor); Jaenisch, Rudolf (Inventor)

    2015-01-01

    The present invention provides a device and methods of use thereof in microscale particle capturing and particle pairing. This invention provides particle patterning device, which mechanically traps individual particles within first chambers of capture units, transfer the particles to second chambers of opposing capture units, and traps a second type of particle in the same second chamber. The device and methods allow for high yield assaying of trapped cells, high yield fusion of trapped, paired cells, for controlled binding of particles to cells and for specific chemical reactions between particle interfaces and particle contents. The device and method provide means of identification of the particle population and a facile route to particle collection.

  8. Intellectual system of identification of Arabic graphics

    NASA Astrophysics Data System (ADS)

    Abdoullayeva, Gulchin G.; Aliyev, Telman A.; Gurbanova, Nazakat G.

    2001-08-01

    The studies made by using the domain of graphic images allowed creating facilities of the artificial intelligence for letters, letter combinations etc. for various graphics and prints. The work proposes a system of recognition and identification of symbols of the Arabic graphics, which has its own specificity as compared to Latin and Cyrillic ones. The starting stage of the recognition and the identification is coding with further entry of information into a computer. Here the problem of entry is one of the essentials. For entry of a large volume of information in the unit of time a scanner is usually employed. Along with the scanner the authors suggest their elaboration of technical facilities for effective input and coding of the information. For refinement of symbols not identified from the scanner mostly for a small bulk of information the developed coding devices are used directly in the process of writing. The functional design of the software is elaborated on the basis of the heuristic model of the creative activity of a researcher and experts in the description and estimation of states of the weakly formalizable systems on the strength of the methods of identification and of selection of geometric features.

  9. Giant switchable photovoltaic effect in organometal trihalide perovskite devices

    DOE PAGES

    Xiao, Zhengguo; Yuan, Yongbo; Shao, Yuchuan; ...

    2014-12-08

    Organolead trihalide perovskite (OTP) materials are emerging as naturally abundant materials for low-cost, solution-processed and highly efficient solar cells. Here, we show that, in OTP-based photovoltaic devices with vertical and lateral cell configurations, the photocurrent direction can be switched repeatedly by applying a small electric field of <1 V μm –1. The switchable photocurrent, generally observed in devices based on ferroelectric materials, reached 20.1 mA cm –2 under one sun illumination in OTP devices with a vertical architecture, which is four orders of magnitude larger than that measured in other ferroelectric photovoltaic devices. This field-switchable photovoltaic effect can be explainedmore » by the formation of reversible p–i–n structures induced by ion drift in the perovskite layer. Furthermore, the demonstration of switchable OTP photovoltaics and electric-field-manipulated doping paves the way for innovative solar cell designs and for the exploitation of OTP materials in electrically and optically readable memristors and circuits.« less

  10. Giant switchable photovoltaic effect in organometal trihalide perovskite devices

    NASA Astrophysics Data System (ADS)

    Xiao, Zhengguo; Yuan, Yongbo; Shao, Yuchuan; Wang, Qi; Dong, Qingfeng; Bi, Cheng; Sharma, Pankaj; Gruverman, Alexei; Huang, Jinsong

    2015-02-01

    Organolead trihalide perovskite (OTP) materials are emerging as naturally abundant materials for low-cost, solution-processed and highly efficient solar cells. Here, we show that, in OTP-based photovoltaic devices with vertical and lateral cell configurations, the photocurrent direction can be switched repeatedly by applying a small electric field of <1 V μm-1. The switchable photocurrent, generally observed in devices based on ferroelectric materials, reached 20.1 mA cm-2 under one sun illumination in OTP devices with a vertical architecture, which is four orders of magnitude larger than that measured in other ferroelectric photovoltaic devices. This field-switchable photovoltaic effect can be explained by the formation of reversible p-i-n structures induced by ion drift in the perovskite layer. The demonstration of switchable OTP photovoltaics and electric-field-manipulated doping paves the way for innovative solar cell designs and for the exploitation of OTP materials in electrically and optically readable memristors and circuits.

  11. On-wafer, cryogenic characterization of ultra-low noise HEMT devices

    NASA Technical Reports Server (NTRS)

    Bautista, J. J.; Laskar, J.; Szydlik, P.

    1995-01-01

    Significant advances in the development of high electron-mobility field-effect transistors (HEMT's) have resulted in cryogenic, low-noise amplifiers (LNA's) whose noise temperatures are within an order of magnitude of the quantum noise limit (hf/k). Further advances in HEMT technology at cryogenic temperatures may eventually lead to the replacement of maser and superconducting insulator superconducting front ends in the 1- to 100-GHz frequency band. Key to identification of the best HEMT's and optimization of cryogenic LNA's are accurate and repeatable device measurements at cryogenic temperatures. This article describes the design and operation of a cryogenic coplanar waveguide probe system for the characterization and modeling of advanced semiconductor transistors at cryogenic temperatures. Results on advanced HEMT devices are presented to illustrate the utility of the measurement system.

  12. Wirelessly powered microfluidic dielectrophoresis devices using printable RF circuits.

    PubMed

    Qiao, Wen; Cho, Gyoujin; Lo, Yu-Hwa

    2011-03-21

    We report the first microfluidic device integrated with a printed RF circuit so the device can be wirelessly powered by a commercially available RFID reader. For conventional dielectrophoresis devices, electrical wires are needed to connect the electric components on the microchip to external equipment such as power supplies, amplifiers, function generators, etc. Such a procedure is unfamiliar to most clinicians and pathologists who are used to working with a microscope for examination of samples on microscope slides. The wirelessly powered device reported here eliminates the entire need for wire attachments and external instruments so the operators can use the device in essentially the same manner as they do with microscope slides. The integrated circuit can be fabricated on a flexible plastic substrate at very low cost using a roll-to-roll printing method. Electrical power at 13.56 MHz transmitted by a radio-frequency identification (RFID) reader is inductively coupled to the printed RFIC and converted into 10 V DC (direct current) output, which provides sufficient power to drive a microfluidic device to manipulate biological particles such as beads and proteins via the DC dielectrophoresis (DC-DEP) effect. To our best knowledge, this is the first wirelessly powered microfluidic dielectrophoresis device. Although the work is preliminary, the device concept, the architecture, and the core technology are expected to stimulate many efforts in the future and transform the technology to a wide range of clinical and point-of-care applications. This journal is © The Royal Society of Chemistry 2011

  13. Technology-Enhanced Formative Assessment of Plant Identification

    NASA Astrophysics Data System (ADS)

    Conejo, Ricardo; Garcia-Viñas, Juan Ignacio; Gastón, Aitor; Barros, Beatriz

    2016-04-01

    Developing plant identification skills is an important part of the curriculum of any botany course in higher education. Frequent practice with dried and fresh plants is necessary to recognize the diversity of forms, states, and details that a species can present. We have developed a web-based assessment system for mobile devices that is able to pose appropriate questions according to the location of the student. A student's location can be obtained using the device position or by scanning a QR code attached to a dried plant sheet in a herbarium or to a fresh plant in an arboretum. The assessment questions are complemented with elaborated feedback that, according to the students' responses, provides indications of possible mistakes and correct answers. Three experiments were designed to measure the effectiveness of the formative assessment using dried and fresh plants. Three questionnaires were used to evaluate the system performance from the students' perspective. The results clearly indicate that formative assessment is objectively effective compared to traditional methods and that the students' attitudes towards the system were very positive.

  14. Method and system for reducing device performance degradation of organic devices

    DOEpatents

    Teague, Lucile C.

    2014-09-02

    Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.

  15. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    NASA Astrophysics Data System (ADS)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  16. Total Ionizing Dose Effects in MOS Oxides and Devices

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy R.; McLean, F. B.

    2003-01-01

    The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.

  17. Effectively Transparent Front Contacts for Optoelectronic Devices

    DOE PAGES

    Saive, Rebecca; Borsuk, Aleca M.; Emmer, Hal S.; ...

    2016-06-10

    Effectively transparent front contacts for optoelectronic devices achieve a measured transparency of up to 99.9% and a measured sheet resistance of 4.8 Ω sq-1. These 3D microscale triangular cross-section grid fingers redirect incoming photons efficiently to the active semiconductor area and can replace standard grid fingers as well as transparent conductive oxide layers in optoelectronic devices. Optoelectronic devices such as light emitting diodes, photodiodes, and solar cells play an important and expanding role in modern technology. Photovoltaics is one of the largest optoelectronic industry sectors and an ever-increasing component of the world's rapidly growing renewable carbon-free electricity generation infrastructure. Inmore » recent years, the photovoltaics field has dramatically expanded owing to the large-scale manufacture of inexpensive crystalline Si and thin film cells and modules. The current record efficiency (η = 25.6%) Si solar cell utilizes a heterostructure intrinsic thin layer (HIT) design[1] to enable increased open circuit voltage, while more mass-manufacturable solar cell architectures feature front contacts.[2, 3] Thus improved solar cell front contact designs are important for future large-scale photovoltaics with even higher efficiency.« less

  18. 47 CFR 74.882 - Station identification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transmission or intermittent transmissions pertaining to a single event. (b) Each wireless video assist device..., AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Low Power Auxiliary Stations § 74.882 Station identification. (a) For transmitters used for voice transmissions and having a transmitter output...

  19. Total-dose radiation effects data for semiconductor devices, volume 3

    NASA Technical Reports Server (NTRS)

    Price, W. E.; Martin, K. E.; Nichols, D. K.; Gauthier, M. K.; Brown, S. F.

    1982-01-01

    Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

  20. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... USE DEVICES General Hospital and Personal Use Miscellaneous Devices § 880.6300 Implantable... identification code is used to access patient identity and corresponding health information stored in a database...

  1. Review of radiation effects on ReRAM devices and technology

    NASA Astrophysics Data System (ADS)

    Gonzalez-Velo, Yago; Barnaby, Hugh J.; Kozicki, Michael N.

    2017-08-01

    A review of the ionizing radiation effects on resistive random access memory (ReRAM) technology and devices is presented in this article. The review focuses on vertical devices exhibiting bipolar resistance switching, devices that have already exhibited interesting properties and characteristics for memory applications and, in particular, for non-volatile memory applications. Non-volatile memories are important devices for any type of electronic and embedded system, as they are for space applications. In such applications, specific environmental issues related to the existence of cosmic rays and Van Allen radiation belts around the Earth contribute to specific failure mechanisms related to the energy deposition induced by such ionizing radiation. Such effects are important in non-volatile memory as the current leading technology, i.e. flash-based technology, is sensitive to the total ionizing dose (TID) and single-event effects. New technologies such as ReRAM, if competing with or complementing the existing non-volatile area of memories from the point of view of performance, also have to exhibit great reliability for use in radiation environments such as space. This has driven research on the radiation effects of such ReRAM technology, on both the conductive-bridge RAM as well as the valence-change memories, or OxRAM variants of the technology. Initial characterizations of ReRAM technology showed a high degree of resilience to TID, developing researchers’ interest in characterizing such resilience as well as investigating the cause of such behavior. The state of the art of such research is reviewed in this article.

  2. Portable Bio/Chemosensoristic Devices: Innovative Systems for Environmental Health and Food Safety Diagnostics.

    PubMed

    Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano

    2017-01-01

    This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an "holistic approach" that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices.

  3. Nonparametric Identification of Causal Effects under Temporal Dependence

    ERIC Educational Resources Information Center

    Dafoe, Allan

    2018-01-01

    Social scientists routinely address temporal dependence by adopting a simple technical fix. However, the correct identification strategy for a causal effect depends on causal assumptions. These need to be explicated and justified; almost no studies do so. This article addresses this shortcoming by offering a precise general statement of the…

  4. The Effect of Technological Devices on Cervical Lordosis.

    PubMed

    Öğrenci, Ahmet; Koban, Orkun; Yaman, Onur; Dalbayrak, Sedat; Yılmaz, Mesut

    2018-03-15

    There is a need for cervical flexion and even cervical hyperflexion for the use of technological devices, especially mobile phones. We investigated the effect of this use on the cervical lordosis angle. A group of 156 patients who applied with only neck pain between 2013-2016 and had no additional problems were included. Patients are specifically questioned about mobile phone, tablet, and other devices usage. The value obtained by multiplying the year of usage and the average usage (hour) in daily life was determined as the total usage value (an average hour per day x year: hy). Cervical lordosis angles were statistically compared with the total time of use. In the general ROC analysis, the cut-off value was found to be 20.5 hy. When the cut-off value is tested, the overall accuracy is very good with 72.4%. The true estimate of true risk and non-risk is quite high. The ROC analysis is statistically significant. The use of computing devices, especially mobile telephones, and the increase in the flexion of the cervical spine indicate that cervical vertebral problems will increase even in younger people in future. Also, to using with attention at this point, ergonomic devices must also be developed.

  5. The Effect of Technological Devices on Cervical Lordosis

    PubMed Central

    Öğrenci, Ahmet; Koban, Orkun; Yaman, Onur; Dalbayrak, Sedat; Yılmaz, Mesut

    2018-01-01

    PURPOSE: There is a need for cervical flexion and even cervical hyperflexion for the use of technological devices, especially mobile phones. We investigated the effect of this use on the cervical lordosis angle. MATERIAL AND METHODS: A group of 156 patients who applied with only neck pain between 2013–2016 and had no additional problems were included. Patients are specifically questioned about mobile phone, tablet, and other devices usage. The value obtained by multiplying the year of usage and the average usage (hour) in daily life was determined as the total usage value (an average hour per day x year: hy). Cervical lordosis angles were statistically compared with the total time of use. RESULTS: In the general ROC analysis, the cut-off value was found to be 20.5 hy. When the cut-off value is tested, the overall accuracy is very good with 72.4%. The true estimate of true risk and non-risk is quite high. The ROC analysis is statistically significant. CONCLUSION: The use of computing devices, especially mobile telephones, and the increase in the flexion of the cervical spine indicate that cervical vertebral problems will increase even in younger people in future. Also, to using with attention at this point, ergonomic devices must also be developed. PMID:29610602

  6. Effectiveness of adverse effects search filters: drugs versus medical devices.

    PubMed

    Farrah, Kelly; Mierzwinski-Urban, Monika; Cimon, Karen

    2016-07-01

    The study tested the performance of adverse effects search filters when searching for safety information on medical devices, procedures, and diagnostic tests in MEDLINE and Embase. The sensitivity of 3 filters was determined using a sample of 631 references from 131 rapid reviews related to the safety of health technologies. The references were divided into 2 sets by type of intervention: drugs and nondrug health technologies. Keyword and indexing analysis were performed on references from the nondrug testing set that 1 or more of the filters did not retrieve. For all 3 filters, sensitivity was lower for nondrug health technologies (ranging from 53%-87%) than for drugs (88%-93%) in both databases. When tested on the nondrug health technologies set, sensitivity was lower in Embase (ranging from 53%-81%) than in MEDLINE (67%-87%) for all filters. Of the nondrug records that 1 or more of the filters missed, 39% of the missed MEDLINE records and 18% of the missed Embase records did not contain any indexing terms related to adverse events. Analyzing the titles and abstracts of nondrug records that were missed by any 1 filter, the most commonly used keywords related to adverse effects were: risk, complications, mortality, contamination, hemorrhage, and failure. In this study, adverse effects filters were less effective at finding information about the safety of medical devices, procedures, and tests compared to information about the safety of drugs.

  7. Photovoltaic and photothermoelectric effect in a double-gated WSe2 device.

    PubMed

    Groenendijk, Dirk J; Buscema, Michele; Steele, Gary A; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf; van der Zant, Herre S J; Castellanos-Gomez, Andres

    2014-10-08

    Tungsten diselenide (WSe2), a semiconducting transition metal dichalcogenide (TMDC), shows great potential as active material in optoelectronic devices due to its ambipolarity and direct bandgap in its single-layer form. Recently, different groups have exploited the ambipolarity of WSe2 to realize electrically tunable PN junctions, demonstrating its potential for digital electronics and solar cell applications. In this Letter, we focus on the different photocurrent generation mechanisms in a double-gated WSe2 device by measuring the photocurrent (and photovoltage) as the local gate voltages are varied independently in combination with above- and below-bandgap illumination. This enables us to distinguish between two main photocurrent generation mechanisms, the photovoltaic and photothermoelectric effect. We find that the dominant mechanism depends on the defined gate configuration. In the PN and NP configurations, photocurrent is mainly generated by the photovoltaic effect and the device displays a maximum responsivity of 0.70 mA/W at 532 nm illumination and rise and fall times close to 10 ms. Photocurrent generated by the photothermoelectric effect emerges in the PP configuration and is a factor of 2 larger than the current generated by the photovoltaic effect (in PN and NP configurations). This demonstrates that the photothermoelectric effect can play a significant role in devices based on WSe2 where a region of strong optical absorption, caused by, for example, an asymmetry in flake thickness or optical absorption of the electrodes, generates a sizable thermal gradient upon illumination.

  8. Side effects of intraoral devices for OSAS treatment.

    PubMed

    Teixeira, Andressa Otranto de Britto; Andrade, Ana Luiza Ladeia; Almeida, Rhita Cristina da Cunha; Almeida, Marco Antonio de Oliveira

    2017-10-14

    Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device. To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices. A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index>0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%. There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences. After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia C

  9. Vibration properties of a rotating piezoelectric energy harvesting device that experiences gyroscopic effects

    NASA Astrophysics Data System (ADS)

    Lu, Haohui; Chai, Tan; Cooley, Christopher G.

    2018-03-01

    This study investigates the vibration of a rotating piezoelectric device that consists of a proof mass that is supported by elastic structures with piezoelectric layers. Vibration of the proof mass causes deformation in the piezoelectric structures and voltages to power the electrical loads. The coupled electromechanical equations of motion are derived using Newtonian mechanics and Kirchhoff's circuit laws. The free vibration behavior is investigated for devices with identical (tuned) and nonidentical (mistuned) piezoelectric support structures and electrical loads. These devices have complex-valued, speed-dependent eigenvalues and eigenvectors as a result of gyroscopic effects caused by their constant rotation. The characteristics of the complex-valued eigensolutions are related to physical behavior of the device's vibration. The free vibration behaviors differ significantly for tuned and mistuned devices. Due to gyroscopic effects, the proof mass in the tuned device vibrates in either forward or backward decaying circular orbits in single-mode free response. This is proven analytically for all tuned devices, regardless of the device's specific parameters or operating speed. For mistuned devices, the proof mass has decaying elliptical forward and backward orbits. The eigenvalues are shown to be sensitive to changes in the electrical load resistances. Closed-form solutions for the eigenvalues are derived for open and close circuits. At high rotation speeds these devices experience critical speeds and instability.

  10. Electrodes mitigating effects of defects in organic electronic devices

    DOEpatents

    Heller, Christian Maria Anton [Albany, NY

    2008-05-06

    A compound electrode for organic electronic devices comprises a thin first layer of a first electrically conducting material and a second electrically conducting material disposed on the first layer. In one embodiment, the second electrically conducting material is formed into a plurality of elongated members. In another embodiment, the second material is formed into a second layer. The elongated members or the second layer has a thickness greater than that of the first layer. The second layer is separated from the first layer by a conducting material having conductivity less than at least the material of the first layer. The compound electrode is capable of mitigating adverse effects of defects, such as short circuits, in the construction of the organic electronic devices, and can be included in light-emitting or photovoltaic devices.

  11. Effects of ocular transverse chromatic aberration on peripheral word identification.

    PubMed

    Yang, Shun-Nan; Tai, Yu-chi; Laukkanen, Hannu; Sheedy, James E

    2011-11-01

    Transverse chromatic aberration (TCA) smears the retinal image of peripheral stimuli. We previously found that TCA significantly reduces the ability to recognize letters presented in the near fovea by degrading image quality and exacerbating crowding effect from adjacent letters. The present study examined whether TCA has a significant effect on near foveal and peripheral word identification, and whether within-word orthographic facilitation interacts with TCA effect to affect word identification. Subjects were briefly presented a 6- to 7-letter word of high or low frequency in each trial. Target words were generated with weak or strong horizontal color fringe to attenuate the TCA in the right periphery and exacerbate it in the left. The center of the target word was 1°, 2°, 4°, and 6° to the left or right of a fixation point. Subject's eye position was monitored with an eye-tracker to ensure proper fixation before target presentation. They were required to report the identity of the target word as soon and accurately as possible. Results show significant effect of color fringe on the latency and accuracy of word recognition, indicating existing TCA effect. Observed TCA effect was more salient in the right periphery, and was affected by word frequency more there. Individuals' subjective preference of color-fringed text was correlated to the TCA effect in the near periphery. Our results suggest that TCA significantly affects peripheral word identification, especially when it is located in the right periphery. Contextual facilitation such as word frequency interacts with TCA to influence the accuracy and latency of word recognition. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Zinc Alloys for the Fabrication of Semiconductor Devices

    NASA Technical Reports Server (NTRS)

    Ryu, Yungryel; Lee, Tae S.

    2009-01-01

    ZnBeO and ZnCdSeO alloys have been disclosed as materials for the improvement in performance, function, and capability of semiconductor devices. The alloys can be used alone or in combination to form active photonic layers that can emit over a range of wavelength values. Materials with both larger and smaller band gaps would allow for the fabrication of semiconductor heterostructures that have increased function in the ultraviolet (UV) region of the spectrum. ZnO is a wide band-gap material possessing good radiation-resistance properties. It is desirable to modify the energy band gap of ZnO to smaller values than that for ZnO and to larger values than that for ZnO for use in semiconductor devices. A material with band gap energy larger than that of ZnO would allow for the emission at shorter wavelengths for LED (light emitting diode) and LD (laser diode) devices, while a material with band gap energy smaller than that of ZnO would allow for emission at longer wavelengths for LED and LD devices. The amount of Be in the ZnBeO alloy system can be varied to increase the energy bandgap of ZnO to values larger than that of ZnO. The amount of Cd and Se in the ZnCdSeO alloy system can be varied to decrease the energy band gap of ZnO to values smaller than that of ZnO. Each alloy formed can be undoped or can be p-type doped using selected dopant elements, or can be n-type doped using selected dopant elements. The layers and structures formed with both the ZnBeO and ZnCdSeO semiconductor alloys - including undoped, p-type-doped, and n-type-doped types - can be used for fabricating photonic and electronic semiconductor devices for use in photonic and electronic applications. These devices can be used in LEDs, LDs, FETs (field effect transistors), PN junctions, PIN junctions, Schottky barrier diodes, UV detectors and transmitters, and transistors and transparent transistors. They also can be used in applications for lightemitting display, backlighting for displays, UV and

  13. Parasitic effects in superconducting quantum interference device-based radiation comb generators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosisio, R., E-mail: riccardo.bosisio@nano.cnr.it; NEST, Instituto Nanoscienze-CNR and Scuola Normale Superiore, I-56127 Pisa; Giazotto, F., E-mail: giazotto@sns.it

    2015-12-07

    We study several parasitic effects on the implementation of a Josephson radiation comb generator based on a dc superconducting quantum interference device (SQUID) driven by an external magnetic field. This system can be used as a radiation generator similarly to what is done in optics and metrology, and allows one to generate up to several hundreds of harmonics of the driving frequency. First we take into account how the assumption of a finite loop geometrical inductance and junction capacitance in each SQUID may alter the operation of the devices. Then, we estimate the effect of imperfections in the fabrication ofmore » an array of SQUIDs, which is an unavoidable source of errors in practical situations. We show that the role of the junction capacitance is, in general, negligible, whereas the geometrical inductance has a beneficial effect on the performance of the device. The errors on the areas and junction resistance asymmetries may deteriorate the performance, but their effect can be limited to a large extent by a suitable choice of fabrication parameters.« less

  14. Single Event Effects in FPGA Devices 2015-2016

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth; Pellish, Jonathan

    2016-01-01

    This presentation provides an overview of single event effects in FPGA devices 2015-2016 including commercial Xilinx V5 heavy ion accelerated testing, Xilinx Kintex-7 heavy ion accelerated testing. Mitigation study, and investigation of various types of triple modular redundancy (TMR) for commercial SRAM based FPGAs.

  15. Single Event Effects in FPGA Devices 2014-2015

    NASA Technical Reports Server (NTRS)

    Berg, Melanie D.; LaBel, Kenneth A.; Pellish, Jonathan

    2015-01-01

    This presentation provides an overview of single event effects in FPGA devices 2014-2015 including commercial Xilinx V5 heavy ion accelerated testing, Xilinx Kintex-7 heavy ion accelerated testing. Mitigation study, and investigation of various types of triple modular redundancy (TMR) for commercial SRAM based FPGAs.

  16. Single Event Effects in FPGA Devices 2015-2016

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth; Pellish, Jonathan

    2016-01-01

    This presentation provides an overview of single event effects in FPGA devices 2015-2016 including commercial Xilinx V5 heavy ion accelerated testing, Xilinx Kintex-7 heavy ion accelerated testing, mitigation study, and investigation of various types of triple modular redundancy (TMR) for commercial SRAM based FPGAs.

  17. Introduction of automated blood pressure devices intended for a low resource setting in rural Tanzania.

    PubMed

    Baker, Elinor Chloe; Hezelgrave, Natasha; Magesa, Stephen M; Edmonds, Sally; de Greeff, Annemarie; Shennan, Andrew

    2012-04-01

    Regular blood pressure (BP) monitoring is a cost-effective means of early identification and management of hypertensive disease in pregnancy. In much of rural sub-Saharan Africa, the ability to take and act on accurate BP measurements is lacking as a result of poorly functioning or absent equipment and/or inadequate staff education. This study describes the feasibility of using validated automated BP devices suitable for low-resource settings (LRS) in primary health-care facilities in rural Tanzania. Following a primary survey, 19 BP devices were distributed to 11 clinics and re-assessed at one, three, six, 12 and 36 months. Devices were used frequently with high levels of user satisfaction and good durability. We conclude that the use of automated BP devices in LRS is feasible and sustainable. An assessment of their ability to reduce maternal and perinatal morbidity and mortality is vital.

  18. Effects of device size and material on the bending performance of resistive-switching memory devices fabricated on flexible substrates

    NASA Astrophysics Data System (ADS)

    Lee, Won-Ho; Yoon, Sung-Min

    2017-05-01

    The resistive change memory (RCM) devices using amorphous In-Ga-Zn-O (IGZO) and microcrystalline Al-doped ZnO (AZO) thin films were fabricated on plastic substrates and characterized for flexible electronic applications. The device cell sizes were varied to 25 × 25, 50 × 50, 100 × 100, and 200 × 200 μm2 to examine the effects of cell size on the resistive-switching (RS) behaviors at a flat state and under bending conditions. First, it was found that the high-resistance state programmed currents markedly increased with the increase in the cell size. Second, while the AZO RCM devices did not exhibit RESET operations at a curvature radius smaller than 8.0 mm, the IGZO RCM devices showed sound RS behaviors even at a curvature radius of 4.5 mm. Third, for the IGZO RCM devices with the cell size bigger than 100 × 100 μm2, the RESET operation could not be performed at a curvature radius smaller than 6.5 mm. Thus, it was elucidated that the RS characteristics of the flexible RCM devices using oxide semiconductor thin films were closely related to the types of RS materials and the cell size of the device.

  19. Evidence of soft bound behaviour in analogue memristive devices for neuromorphic computing.

    PubMed

    Frascaroli, Jacopo; Brivio, Stefano; Covi, Erika; Spiga, Sabina

    2018-05-08

    The development of devices that can modulate their conductance under the application of electrical stimuli constitutes a fundamental step towards the realization of synaptic connectivity in neural networks. Optimization of synaptic functionality requires the understanding of the analogue conductance update under different programming conditions. Moreover, properties of physical devices such as bounded conductance values and state-dependent modulation should be considered as they affect storage capacity and performance of the network. This work provides a study of the conductance dynamics produced by identical pulses as a function of the programming parameters in an HfO 2 memristive device. The application of a phenomenological model that considers a soft approach to the conductance boundaries allows the identification of different operation regimes and to quantify conductance modulation in the analogue region. Device non-linear switching kinetics is recognized as the physical origin of the transition between different dynamics and motivates the crucial trade-off between degree of analog modulation and memory window. Different kinetics for the processes of conductance increase and decrease account for device programming asymmetry. The identification of programming trade-off together with an evaluation of device variations provide a guideline for the optimization of the analogue programming in view of hardware implementation of neural networks.

  20. Radiation Effects on Optoelectronic Devices in Space Missions

    NASA Technical Reports Server (NTRS)

    Johnston, Allan H.

    2006-01-01

    Radiation degradation of optoelectronic devices is discussed, including effects on optical emitters, detectors and optocouplers. The importance of displacement damage is emphasized, including the limitations of non-ionizing energy loss (NIEL) in normalizing damage. Failures of optoelectronics in fielded space systems are discussed, along with testing and qualification methods.

  1. Effectiveness of light-reflecting devices: A systematic reanalysis of animal-vehicle collision data.

    PubMed

    Brieger, Falko; Hagen, Robert; Vetter, Daniela; Dormann, Carsten F; Storch, Ilse

    2016-12-01

    Every year, approximately 500 human fatalities occur due to animal-vehicle collisions in the United States and Europe. Especially heavy-bodied animals affect road safety. For more than 50 years, light-reflecting devices such as wildlife warning reflectors have been employed to alert animals to traffic when crossing roads during twilight and night. Numerous studies addressed the effectiveness of light-reflecting devices in reducing collisions with animals in past decades, but yielded contradictory results. In this study, we conducted a systematic literature review to investigate whether light-reflecting devices contribute to an effective prevention of animal-vehicle collisions. We reviewed 53 references and reanalyzed original data of animal-vehicle collisions with meta-analytical methods. We calculated an effect size based on the annual number of animal-vehicle collisions per kilometer of road to compare segments with and without the installation of light-reflecting devices for 185 roads in Europe and North America. Our results indicate that light-reflecting devices did not significantly reduce the number of animal-vehicle collisions. However, we observed considerable differences of effect sizes with respect to study duration, study design, and country. Our results suggest that length of the road segment studied, study duration, study design and public attitude (preconception) to the functioning of devices may affect whether the documented number of animal-vehicle collisions in- or decrease and might in turn influence whether results obtained were published. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Study of CPM Device used for Rehabilitation and Effective Pain Management Following Knee Alloplasty

    NASA Astrophysics Data System (ADS)

    Trochimczuk, R.; Kuźmierowski, T.; Anchimiuk, P.

    2017-02-01

    This paper defines the design assumptions for the construction of an original demonstration of a CPM device, based on which a solid virtual model will be created in a CAD software environment. The overall dimensions and other input parameters for the design were determined for the entire patient population according to an anatomical atlas of human measures. The medical and physiotherapeutic community were also consulted with respect to the proposed engineering solutions. The virtual model of the CPM device that will be created will be used for computer simulations of changes in motion parameters as a function of time, accounting for loads and static states. The results obtained from computer simulation will be used to confirm the correctness of the design adopted assumptions and of the accepted structure of the CPM mechanism, and potentially to introduce necessary corrections. They will also provide a basis for the development of a control strategy for the laboratory prototype and for the selection of the strategy of the patient's rehabilitation in the future. This paper will be supplemented with identification of directions of further research.

  3. Paper Capillary Enables Effective Sampling for Microfluidic Paper Analytical Devices.

    PubMed

    Shangguan, Jin-Wen; Liu, Yu; Wang, Sha; Hou, Yun-Xuan; Xu, Bi-Yi; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-06-06

    Paper capillary is introduced to enable effective sampling on microfluidic paper analytical devices. By coupling mac-roscale capillary force of paper capillary and microscale capillary forces of native paper, fluid transport can be flexibly tailored with proper design. Subsequently, a hybrid-fluid-mode paper capillary device was proposed, which enables fast and reliable sampling in an arrayed form, with less surface adsorption and bias for different components. The resulting device thus well supports high throughput, quantitative, and repeatable assays all by hands operation. With all these merits, multiplex analysis of ions, proteins, and microbe have all been realized on this platform, which has paved the way to level-up analysis on μPADs.

  4. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    PubMed

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  5. Remote two-wire data entry method and device

    DOEpatents

    Kronberg, James W.

    1995-01-01

    A device for detecting switch closure such as in a keypad for entering data comprising a matrix of conductor pairs and switches, each pair of conductors shorted by the pressing of a particular switch, and current-regulating devices on each conductor for limiting current in one direction and passing it without limit in the other direction. The device is driven by alternating current. The ends of the conductors in a conductor pair limit current of opposing polarities with respect to each other so that the signal on a shorted pair is an alternating current signal with a unique combination of a positive and a negative peak, which, when analyzed, allows the determination of which key was pressed. The binary identification of the pressed key is passed to the input port of a host device.

  6. Radiation hardening of MOS devices by boron. [for stabilizing gate threshold potential of field effect device

    NASA Technical Reports Server (NTRS)

    Danchenko, V. (Inventor)

    1974-01-01

    A technique is described for radiation hardening of MOS devices and specifically for stabilizing the gate threshold potential at room temperature of a radiation subjected MOS field-effect device with a semiconductor substrate, an insulating layer of oxide on the substrate, and a gate electrode disposed on the insulating layer. The boron is introduced within a layer of the oxide of about 100 A-300 A thickness immediately adjacent the semiconductor-insulator interface. The concentration of boron in the oxide layer is preferably maintained on the order of 10 to the 18th power atoms/cu cm. The technique serves to reduce and substantially annihilate radiation induced positive gate charge accumulations.

  7. Snapshot spectral and polarimetric imaging; target identification with multispectral video

    NASA Astrophysics Data System (ADS)

    Bartlett, Brent D.; Rodriguez, Mikel D.

    2013-05-01

    As the number of pixels continue to grow in consumer and scientific imaging devices, it has become feasible to collect the incident light field. In this paper, an imaging device developed around light field imaging is used to collect multispectral and polarimetric imagery in a snapshot fashion. The sensor is described and a video data set is shown highlighting the advantage of snapshot spectral imaging. Several novel computer vision approaches are applied to the video cubes to perform scene characterization and target identification. It is shown how the addition of spectral and polarimetric data to the video stream allows for multi-target identification and tracking not possible with traditional RGB video collection.

  8. Nano Peltier cooling device from geometric effects using a single graphene nanoribbon

    NASA Astrophysics Data System (ADS)

    Li, Wan-Ju; Yao, Dao-Xin; Carlson, Erica

    2012-02-01

    Based on the phenomenon of curvature-induced doping in graphene we propose a class of Peltier cooling devices, produced by geometrical effects, without gating. We show how a graphene nanoribbon laid on an array of curved nano cylinders can be used to create a targeted cooling device. Using theoretical calculations and experimental inputs, we predict that the cooling power of such a device can approach 1kW/cm^2, on par with the best known techniques using standard lithography methods. The structure proposed here helps pave the way toward designing graphene electronics which use geometry rather than gating to control devices.

  9. Performance characterization of material identification systems

    NASA Astrophysics Data System (ADS)

    Brown, Christopher D.; Green, Robert L.

    2006-10-01

    In recent years a number of analytical devices have been proposed and marketed specifically to enable field-based material identification. Technologies reliant on mass, near- and mid-infrared, and Raman spectroscopies are available today, and other platforms are imminent. These systems tend to perform material recognition based on an on-board library of material signatures. While figures of merit for traditional quantitative analytical sensors are broadly established (e.g., SNR, selectivity, sensitivity, limit of detection/decision), measures of performance for material identification systems have not been systematically discussed. In this paper we present an approach to performance characterization similar in spirit to ROC curves, but including elements of precision-recall curves and specialized for the intended-use of material identification systems. Important experimental considerations are discussed, including study design, sources of bias, uncertainty estimation, and cross-validation and the approach as a whole is illustrated using a commercially available handheld Raman material identification system.

  10. An open source device for operant licking in rats.

    PubMed

    Longley, Matthew; Willis, Ethan L; Tay, Cindy X; Chen, Hao

    2017-01-01

    We created an easy-to-use device for operant licking experiments and another device that records environmental variables. Both devices use the Raspberry Pi computer to obtain data from multiple input devices (e.g., radio frequency identification tag readers, touch and motion sensors, environmental sensors) and activate output devices (e.g., LED lights, syringe pumps) as needed. Data gathered from these devices are stored locally on the computer but can be automatically transferred to a remote server via a wireless network. We tested the operant device by training rats to obtain either sucrose or water under the control of a fixed ratio, a variable ratio, or a progressive ratio reinforcement schedule. The lick data demonstrated that the device has sufficient precision and time resolution to record the fast licking behavior of rats. Data from the environment monitoring device also showed reliable measurements. By providing the source code and 3D design under an open source license, we believe these examples will stimulate innovation in behavioral studies. The source code can be found at http://github.com/chen42/openbehavior.

  11. An open source device for operant licking in rats

    PubMed Central

    Longley, Matthew; Willis, Ethan L.; Tay, Cindy X.

    2017-01-01

    We created an easy-to-use device for operant licking experiments and another device that records environmental variables. Both devices use the Raspberry Pi computer to obtain data from multiple input devices (e.g., radio frequency identification tag readers, touch and motion sensors, environmental sensors) and activate output devices (e.g., LED lights, syringe pumps) as needed. Data gathered from these devices are stored locally on the computer but can be automatically transferred to a remote server via a wireless network. We tested the operant device by training rats to obtain either sucrose or water under the control of a fixed ratio, a variable ratio, or a progressive ratio reinforcement schedule. The lick data demonstrated that the device has sufficient precision and time resolution to record the fast licking behavior of rats. Data from the environment monitoring device also showed reliable measurements. By providing the source code and 3D design under an open source license, we believe these examples will stimulate innovation in behavioral studies. The source code can be found at http://github.com/chen42/openbehavior. PMID:28229020

  12. 21 CFR 876.5310 - Nonimplanted, peripheral electrical continence device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a peripheral location and used to stimulate the nerves associated with pelvic floor function to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonimplanted, peripheral electrical continence....5310 Nonimplanted, peripheral electrical continence device. (a) Identification. A nonimplanted...

  13. 27 CFR 479.63 - Identification of applicant.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2012-04-01 2010-04-01 true Identification of applicant. 479.63 Section 479.63 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND...

  14. 27 CFR 479.85 - Identification of transferee.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2013-04-01 2013-04-01 false Identification of transferee. 479.85 Section 479.85 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  15. 27 CFR 479.63 - Identification of applicant.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2013-04-01 2013-04-01 false Identification of applicant. 479.63 Section 479.63 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  16. 27 CFR 479.85 - Identification of transferee.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2011-04-01 2010-04-01 true Identification of transferee. 479.85 Section 479.85 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  17. 27 CFR 479.35 - Employer identification number.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2014-04-01 2014-04-01 false Employer identification number. 479.35 Section 479.35 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  18. 27 CFR 479.35 - Employer identification number.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2012-04-01 2010-04-01 true Employer identification number. 479.35 Section 479.35 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  19. 27 CFR 479.63 - Identification of applicant.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Identification of applicant. 479.63 Section 479.63 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  20. 27 CFR 479.85 - Identification of transferee.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2012-04-01 2010-04-01 true Identification of transferee. 479.85 Section 479.85 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  1. 27 CFR 479.85 - Identification of transferee.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2014-04-01 2014-04-01 false Identification of transferee. 479.85 Section 479.85 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  2. 27 CFR 479.35 - Employer identification number.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2011-04-01 2010-04-01 true Employer identification number. 479.35 Section 479.35 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  3. 27 CFR 479.63 - Identification of applicant.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2014-04-01 2014-04-01 false Identification of applicant. 479.63 Section 479.63 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  4. 27 CFR 479.63 - Identification of applicant.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2011-04-01 2010-04-01 true Identification of applicant. 479.63 Section 479.63 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND...

  5. 27 CFR 479.85 - Identification of transferee.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Identification of transferee. 479.85 Section 479.85 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  6. 27 CFR 479.35 - Employer identification number.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Employer identification number. 479.35 Section 479.35 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  7. 27 CFR 479.35 - Employer identification number.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2013-04-01 2013-04-01 false Employer identification number. 479.35 Section 479.35 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES...

  8. The effect of image alterations on identification using palmar flexion creases.

    PubMed

    Cook, Tom; Sutton, Raul; Buckley, Kevan

    2013-11-01

    Palmprints are identified using matching of minutia points, which can be time consuming for fingerprint experts and in database searches. This article analyzes the operational characteristics of a palmar flexion crease (PFC) identification software tool, using a dataset of 10 replicates of 100 palms, where the user can label and match palmar line features. Results show that 100 palmprint images modified 10 times each using rotation, translation, and additive noise, mimicking some of the characteristics found in crime scene palmar marks, can be identified with a 99.2% genuine acceptance rate and 0% false acceptance rate when labeled within 3.5 mm of the PFC. Partial palmprint images can also be identified using the same method to filter the dataset prior to traditional matching, while maintaining an effective genuine acceptance rate. The work shows that identification using PFCs can improve palmprint identification through integration with existing systems, and through dedicated palmprint identification applications. © 2013 American Academy of Forensic Sciences.

  9. Assessment of Safety and Interference Issues of Radio Frequency Identification Devices in 0.3 Tesla Magnetic Resonance Imaging and Computed Tomography

    PubMed Central

    Periyasamy, M.; Dhanasekaran, R.

    2014-01-01

    The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI) including device functionality and image artifacts for the presence of radio frequency identification devices (RFID) in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT) scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types) were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal) relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning. PMID:24701187

  10. Optical effects of shadow masks on short circuit current of organic photovoltaic devices.

    PubMed

    Lin, Chi-Feng; Lin, Bing-Hong; Liu, Shun-Wei; Hsu, Wei-Feng; Zhang, Mi; Chiu, Tien-Lung; Wei, Mau-Kuo; Lee, Jiun-Haw

    2012-03-21

    In this paper, we have employed different shadow masks attached on top of organic photovoltaic (OPV) devices to study the optical effects of the former on the short circuit current (J(SC)). To rule out possible lateral electrical conduction and simplify the optical effects inside the device, a small-molecular heterojunction OPV device with a clear donor/acceptor interface was employed with a hole extraction layer exhibiting high resistance intentionally. Careful calibration with a shadow mask was employed. By attaching two layers of opaque masks in combination with a suitable holder design to shield the light from the edges and backside, the value of J(SC) approached that of the dark current, even under 1-sun radiation. With different illumination areas, we found that the photons illuminating the non-active region of the device contributed to 40% of the J(SC) by optical effect within the width of about 1 mm around the active region. When illuminating the non-active area with 12 mm to the active area, a 5.6 times improvement in the J(SC) was observed when the incident angle was 75°. With the introduction of a microstructured film onto the OPV device and an increase in the reflection from the non-active region, a 15% enhancement of the J(SC) compared to the control device was achieved.

  11. Technology assessment of medical devices at the Center for Devices and Radiological Health.

    PubMed

    Kessler, L; Richter, K

    1998-09-25

    We reviewed the Food and Drug Administration's regulatory process for medical devices and described the issues that arise in assessing device safety and effectiveness during the postmarket period. The Center for Devices and Radiological Health (CDRH), an organization within the Food and Drug Administration, has the legal authority and responsibility for ensuring that medical devices marketed in the United States are both reasonably safe and effective for their intended use. This is an enormous challenge given the diversity of medical devices and the large number of different types of devices on the market. Many scientific and regulatory activities are necessary to ensure device safety and effectiveness, including technology assessment, albeit in a manner quite different from that of conventional technology assessment. The basic approach taken at the CDRH to ensure device safety and effectiveness is to develop an understanding of the way in which a medical device works and how it will perform in clinical situations.

  12. Open quantum systems, effective Hamiltonians, and device characterization

    NASA Astrophysics Data System (ADS)

    Duffus, S. N. A.; Dwyer, V. M.; Everitt, M. J.

    2017-10-01

    High fidelity models, which are able to both support accurate device characterization and correctly account for environmental effects, are crucial to the engineering of scalable quantum technologies. As it ensures positivity of the density matrix, one preferred model of open systems describes the dynamics with a master equation in Lindblad form. In practice, Linblad operators are rarely derived from first principles, and often a particular form of annihilator is assumed. This results in dynamical models that miss those additional terms which must generally be added for the master equation to assume the Lindblad form, together with the other concomitant terms that must be assimilated into an effective Hamiltonian to produce the correct free evolution. In first principles derivations, such additional terms are often canceled (or countered), frequently in a somewhat ad hoc manner, leading to a number of competing models. Whilst the implications of this paper are quite general, to illustrate the point we focus here on an example anharmonic system; specifically that of a superconducting quantum interference device (SQUID) coupled to an Ohmic bath. The resulting master equation implies that the environment has a significant impact on the system's energy; we discuss the prospect of keeping or canceling this impact and note that, for the SQUID, monitoring the magnetic susceptibility under control of the capacitive coupling strength and the externally applied flux results in experimentally measurable differences between a number of these models. In particular, one should be able to determine whether a squeezing term of the form X ̂P ̂+P ̂X ̂ should be present in the effective Hamiltonian or not. If model generation is not performed correctly, device characterization will be prone to systemic errors.

  13. The Effect of Exposure Duration on Visual Character Identification in Single, Whole, and Partial Report

    ERIC Educational Resources Information Center

    Petersen, Anders; Andersen, Tobias S.

    2012-01-01

    The psychometric function of single-letter identification is typically described as a function of stimulus intensity. However, the effect of stimulus exposure duration on letter identification remains poorly described. This is surprising because the effect of exposure duration has played a central role in modeling performance in whole and partial…

  14. Portable Bio/Chemosensoristic Devices: Innovative Systems for Environmental Health and Food Safety Diagnostics

    PubMed Central

    Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano

    2017-01-01

    This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an “holistic approach” that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices. PMID:28529937

  15. Effectiveness study of UNL's pneumatic crack/joint preparation device.

    DOT National Transportation Integrated Search

    2014-03-01

    The aim of this project was to evaluate the effectiveness of the crack cleaning device (CCD) for improving the current crack/joint preparation practices and for possible adoption as a standard in Nebraska Department of Roads (NDOR). Through the colla...

  16. Comparison of visual and electronic devices for individual identification of dromedary camels under different farming conditions.

    PubMed

    Caja, G; Díaz-Medina, E; Salama, A A K; Salama, O A E; El-Shafie, M H; El-Metwaly, H A; Ayadi, M; Aljumaah, R S; Alshaikh, M A; Yahyahoui, M H; Seddik, M M; Hammadi, M; Khorchani, T; Amann, O; Cabrera, S

    2016-08-01

    The camel industry uses traditional (i.e., iron brands and ear tags) and modern (i.e., microchips) identification (ID) systems without having performance results of reference. Previously iron-branded ( = 45; 1 yr) and microchipped ( = 59; 7 yr) camels showed problems of healing (8.6% of brands) and reading (only 42.9% of brands and 69.5% of microchips were readable), which made their use inadvisable. With the aim of proposing suitable ID systems for different farming conditions, an on-field study was performed using a total of 528 dromedaries at 4 different locations (Egypt, = 83; Spain, = 304; Saudi Arabia, = 90; and Tunisia, = 51). The ID devices tested were visual (button ear tags, 28.5 mm diameter, = 178; double flag ear tags, 50 by 15 mm, = 83; both made of polyurethane) and electronic (ear tags, = 90, and rumen boluses, = 555). Electronic ear tags were polyurethane-loop type (75 by 9 mm) with a container in which a 22-mm transponder of full-duplex technology was lodged. Electronic boluses of 7 types, varying in dimensions (50 to 76 mm length, 11 to 21 mm width, and 12.7 to 82.1 g weight) and specific gravity (SG; 1.49 to 3.86) and each of them containing a 31-mm transponder of half-duplex technology, were all administered to the dromedaries at the beginning of the study. When a low-SG bolus was lost, a high-SG bolus was readministered. Readability rates of each ID system were evaluated during 1 to 3 yr, according to device and location, and yearly values were estimated for comparison. On a yearly basis, visual ear tag readability was not fully satisfactory; it was lower for rectangular ear tags (66.3%) than for button ear tags (80.9%). Yearly readability of electronic ear tags was 93.7%. Bolus readability dramatically varied according to their SG; the SG < 2.0 boluses were fully lost after 8 mo. In contrast, the SG > 3.0 boluses were efficiently retained (99.6 to 100%) at all locations. In conclusion, according to the expected long lifespan of camels, low ID

  17. Subsonic Maneuvering Effectiveness of High Performance Aircraft Which Employ Quasi-Static Shape Change Devices

    NASA Technical Reports Server (NTRS)

    Montgomery, Raymond C.; Scott, Michael A.; Weston, Robert P.

    1998-01-01

    This paper represents an initial study on the use of quasi-static shape change devices in aircraft maneuvering. The macroscopic effects and requirements for these devices in flight control are the focus of this study. Groups of devices are postulated to replace the conventional leading-edge flap (LEF) and the all-moving wing tip (AMT) on the tailless LMTAS-ICE (Lockheed Martin Tactical Aircraft Systems - Innovative Control Effectors) configuration. The maximum quasi-static shape changes are 13.8% and 7.7% of the wing section thickness for the LEF and AMT replacement devices, respectively. A Computational Fluid Dynamics (CFD) panel code is used to determine the control effectiveness of groups of these devices. A preliminary design of a wings-leveler autopilot is presented. Initial evaluation at 0.6 Mach at 15,000 ft. altitude is made through batch simulation. Results show small disturbance stability is achieved, however, an increase in maximum distortion is needed to statically offset five degrees of sideslip. This only applies to the specific device groups studied, encouraging future research on optimal device placement.

  18. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  19. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  20. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  1. 47 CFR 80.275 - Technical Requirements for Class A Automatic Identification System (AIS) equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Compulsory Ships § 80.275 Technical Requirements for Class A Automatic Identification System (AIS) equipment. (a) Prior to submitting a certification application for a Class A AIS device, the following... Identification System (AIS) equipment. 80.275 Section 80.275 Telecommunication FEDERAL COMMUNICATIONS COMMISSION...

  2. Effect of attention on the detection and identification of masked spatial patterns.

    PubMed

    Põder, Endel

    2005-01-01

    The effect of attention on the detection and identification of vertically and horizontally oriented Gabor patterns in the condition of simultaneous masking with obliquely oriented Gabors was studied. Attention was manipulated by varying the set size in a visual-search experiment. In the first experiment, small target Gabors were presented on the background of larger masking Gabors. In the detection task, the effect of set size was as predicted by unlimited-capacity signal detection theory. In the orientation identification task, increasing the set size from 1 to 8 resulted in a much larger decline in performance. The results of the additional experiments suggest that attention can reduce the crowding effect of maskers.

  3. Effects of personal identifier resynthesis on clinical text de-identification.

    PubMed

    Yeniterzi, Reyyan; Aberdeen, John; Bayer, Samuel; Wellner, Ben; Hirschman, Lynette; Malin, Bradley

    2010-01-01

    De-identified medical records are critical to biomedical research. Text de-identification software exists, including "resynthesis" components that replace real identifiers with synthetic identifiers. The goal of this research is to evaluate the effectiveness and examine possible bias introduced by resynthesis on de-identification software. We evaluated the open-source MITRE Identification Scrubber Toolkit, which includes a resynthesis capability, with clinical text from Vanderbilt University Medical Center patient records. We investigated four record classes from over 500 patients' files, including laboratory reports, medication orders, discharge summaries and clinical notes. We trained and tested the de-identification tool on real and resynthesized records. We measured performance in terms of precision, recall, F-measure and accuracy for the detection of protected health identifiers as designated by the HIPAA Safe Harbor Rule. The de-identification tool was trained and tested on a collection of real and resynthesized Vanderbilt records. Results for training and testing on the real records were 0.990 accuracy and 0.960 F-measure. The results improved when trained and tested on resynthesized records with 0.998 accuracy and 0.980 F-measure but deteriorated moderately when trained on real records and tested on resynthesized records with 0.989 accuracy 0.862 F-measure. Moreover, the results declined significantly when trained on resynthesized records and tested on real records with 0.942 accuracy and 0.728 F-measure. The de-identification tool achieves high accuracy when training and test sets are homogeneous (ie, both real or resynthesized records). The resynthesis component regularizes the data to make them less "realistic," resulting in loss of performance particularly when training on resynthesized data and testing on real data.

  4. Remote two-wire data entry method and device

    DOEpatents

    Kronberg, J.W.

    1991-01-01

    This invention is comprised of a device for detecting switch closure such as in a keypad for entering data comprising a matrix of conductor pairs and switches, each pair of conductors shorted by the pressing of a particular switch, and current-regulating devices on each conductor for limiting current in one direction and passing it without limit in the other direction. The device is driven by alternating current. The ends of the conductors in a conductor pair limit current of opposing polarities with respect to each other so that the signal on a shorted pair is an alternating current signal with a unique combination of a positive and a negative peak, which, when analyzed, allows the determination of which key was pressed. The binary identification of the pressed key is passed to the input port of a host device.

  5. Features of the piezo-phototronic effect on optoelectronic devices based on wurtzite semiconductor nanowires.

    PubMed

    Yang, Qing; Wu, Yuanpeng; Liu, Ying; Pan, Caofeng; Wang, Zhong Lin

    2014-02-21

    The piezo-phototronic effect, a three way coupling effect of piezoelectric, semiconductor and photonic properties in non-central symmetric semiconductor materials, utilizing the piezo-potential as a "gate" voltage to tune the charge transport/generation/recombination and modulate the performance of optoelectronic devices, has formed a new field and attracted lots of interest recently. The mechanism was verified in various optoelectronic devices such as light emitting diodes (LEDs), photodetectors and solar cells etc. The fast development and dramatic increasing interest in the piezo-phototronic field not only demonstrate the way the piezo-phototronic effects work, but also indicate the strong need for further research in the physical mechanism and potential applications. Furthermore, it is important to distinguish the contribution of the piezo-phototronic effect from other factors induced by external strain such as piezoresistance, band shifting or contact area change, which also affect the carrier behaviour and device performance. In this perspective, we review our recent progress on piezo-phototronics and especially focus on pointing out the features of piezo-phototronic effect in four aspects: I-V characteristics; c-axis orientation; influence of illumination; and modulation of carrier behaviour. Finally we proposed several criteria for describing the contribution made by the piezo-phototronic effect to the performance of optoelectronic devices. This systematic analysis and comparison will not only help give an in-depth understanding of the piezo-phototronic effect, but also work as guide for the design of devices in related areas.

  6. The Role of Ethnic and National Identifications in Perceived Discrimination for Asian Americans: Toward a Better Understanding of the Buffering Effect of Group Identifications on Psychological Distress

    PubMed Central

    Huynh, Que-Lam; Devos, Thierry; Goldberg, Robyn

    2013-01-01

    A robust relationship between perceived racial discrimination and psychological distress has been established. Yet, mixed evidence exists regarding the extent to which ethnic identification moderates this relationship, and scarce attention has been paid to the moderating role of national identification. We propose that the role of group identifications in the perceived discrimination–psychological distress relationship is best understood by simultaneously and interactively considering ethnic and national identifications. A sample of 259 Asian American students completed measures of perceived discrimination, group identifications (specific ethnic identification stated by respondents and national or “mainstream American” identification), and psychological distress (anxiety and depression symptoms). Regression analyses revealed a significant three-way interaction of perceived discrimination, ethnic identification, and national identification on psychological distress. Simple-slope analyses indicated that dual identification (strong ethnic and national identifications) was linked to a weaker relationship between perceived discrimination and psychological distress compared with other group identification configurations. These findings underscore the need to consider the interconnections between ethnic and national identifications to better understand the circumstances under which group identifications are likely to buffer individuals against the adverse effects of racial discrimination. PMID:25258674

  7. Optimizing the construction of devices to control inaccesible surfaces - case study

    NASA Astrophysics Data System (ADS)

    Niţu, E. L.; Costea, A.; Iordache, M. D.; Rizea, A. D.; Babă, Al

    2017-10-01

    The modern concept for the evolution of manufacturing systems requires multi-criteria optimization of technological processes and equipments, prioritizing associated criteria according to their importance. Technological preparation of the manufacturing can be developed, depending on the volume of production, to the limit of favourable economical effects related to the recovery of the costs for the design and execution of the technological equipment. Devices, as subsystems of the technological system, in the general context of modernization and diversification of machines, tools, semi-finished products and drives, are made in a multitude of constructive variants, which in many cases do not allow their identification, study and improvement. This paper presents a case study in which the multi-criteria analysis of some structures, based on a general optimization method, of novelty character, is used in order to determine the optimal construction variant of a control device. The rational construction of the control device confirms that the optimization method and the proposed calculation methods are correct and determine a different system configuration, new features and functions, and a specific method of working to control inaccessible surfaces.

  8. Nosewitness Identification: Effects of Negative Emotion

    PubMed Central

    Ferreira, Jacqueline; Rocha, Marta; Silva, Carlos F.; Olsson, Mats J.

    2015-01-01

    Every individual has a unique body odor (BO), similar to a fingerprint. In forensic research, identification of culprit BOs has been performed by trained dogs, but not by humans. We introduce the concept of nosewitness identification and present the first experimental results on BO memory in witness situations involving violent crimes. Two experiments indicated that BO associated with male characters in authentic videos could later be identified in BO lineup tests well above chance. Moreover, culprit BO in emotional crime videos could be identified considerably better than the BO of a male person in neutral videos. This indicates that nosewitness identification benefits from emotional encoding. Altogether, the study testifies to the virtue of body odor as a cue to identify individuals observed under negative emotion. PMID:25612211

  9. System and method for controlling remote devices

    DOEpatents

    Carrender, Curtis Lee [Richland, WA; Gilbert, Ronald W [Benton City, WA; Scott, Jeff W [Pasco, WA; Clark, David A [Kennewick, WA

    2006-02-07

    A system and method for controlling remote devices utilizing a radio frequency identification (RFID) tag device having a control circuit adapted to render the tag device, and associated objects, permanently inoperable in response to radio-frequency control signals. The control circuit is configured to receive the control signals that can include an enable signal, and in response thereto enable an associated object, such as a weapon; and in response to a disable signal, to disable the tag itself, or, if desired, to disable the associated weapon or both the device and the weapon. Permanent disabling of the tag can be accomplished by several methods, including, but not limited to, fusing a fusable link, breaking an electrically conductive path, permanently altering the modulation or backscattering characteristics of the antenna circuit, and permanently erasing an associated memory. In this manner, tags in the possession of unauthorized employees can be remotely disabled, and weapons lost on a battlefield can be easily tracked and enabled or disabled automatically or at will.

  10. The Effects of Social Identification and Organizational Identification on Student Commitment, Achievement and Satisfaction in Higher Education

    ERIC Educational Resources Information Center

    Wilkins, Stephen; Butt, Muhammad Mohsin; Kratochvil, Daniel; Balakrishnan, Melodena Stephens

    2016-01-01

    The purpose of this research is to investigate the effects of social and organizational identifications on student commitment, achievement and satisfaction in higher education. The sample comprised 437 students enrolled in an undergraduate or postgraduate programme in business or management. A model was developed and tested using structural…

  11. Modeling Self-Heating Effects in Nanoscale Devices

    NASA Astrophysics Data System (ADS)

    Raleva, K.; Shaik, A. R.; Vasileska, D.; Goodnick, S. M.

    2017-08-01

    Accurate thermal modeling and the design of microelectronic devices and thin film structures at the micro- and nanoscales poses a challenge to electrical engineers who are less familiar with the basic concepts and ideas in sub-continuum heat transport. This book aims to bridge that gap. Efficient heat removal methods are necessary to increase device performance and device reliability. The authors provide readers with a combination of nanoscale experimental techniques and accurate modeling methods that must be employed in order to determine a device's temperature profile.

  12. Integrated fountain effect pump device for fluid management at low gravity

    NASA Technical Reports Server (NTRS)

    Yuan, S. W. K.; Frank, D. J.

    1988-01-01

    A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.

  13. Is facial skin tone sufficient to produce a cross-racial identification effect?

    PubMed

    Alley, T R; Schultheis, J A

    2001-06-01

    Research clearly supports the existence of an other race effect for human faces whereby own-race faces are more accurately perceived and recognized. Why this occurs remains unclear. A computerized program (Mac-a-Mug Pro) for face composition was used to create pairs of target and distractor faces that differed only in skin tone. The six target faces were rated on honesty and aggressiveness by 72 university students, with just one 'Black' and one 'White' face viewed by each student. One week later, they attempted to identify these faces in four lineups: two with target-present and two with target-absent. The order of presentation of targets, lineups, and faces within lineups was varied. Own-race identification was slightly better than cross-racial identification. There was no significant difference in the confidence of responses to own- versus other-race faces. These results indicate that neither morphological variation nor differential confidence is necessary for a cross-racial identification effect.

  14. McGurk Effect in Gender Identification: Vision Trumps Audition in Voice Judgments.

    PubMed

    Peynircioǧlu, Zehra F; Brent, William; Tatz, Joshua R; Wyatt, Jordan

    2017-01-01

    Demonstrations of non-speech McGurk effects are rare, mostly limited to emotion identification, and sometimes not considered true analogues. We presented videos of males and females singing a single syllable on the same pitch and asked participants to indicate the true range of the voice-soprano, alto, tenor, or bass. For one group of participants, the gender shown on the video matched the gender of the voice heard, and for the other group they were mismatched. Soprano or alto responses were interpreted as "female voice" decisions and tenor or bass responses as "male voice" decisions. Identification of the voice gender was 100% correct in the preceding audio-only condition. However, whereas performance was also 100% correct in the matched video/audio condition, it was only 31% correct in the mismatched video/audio condition. Thus, the visual gender information overrode the voice gender identification, showing a robust non-speech McGurk effect.

  15. 40 CFR 63.1003 - Equipment identification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Equipment identification. 63.1003... device, under the provisions of § 63.1007(e)(3) (pumps in light liquid service), § 63.1009(e)(3... meeting the provisions of § 63.1007(e)(5), connectors meeting the provisions of § 63.1008(d)(1), and...

  16. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  17. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification.

    PubMed

    Bizzini, A; Greub, G

    2010-11-01

    Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1-93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  18. Raman scattering spectroscopy for explosives identification

    NASA Astrophysics Data System (ADS)

    Nagli, L.; Gaft, M.

    2007-04-01

    Real time detection and identification of explosives at a standoff distance is a major issue in efforts to develop defense against so-called Improvised Explosive Devices (IED). It is recognized that the only technique, which is potentially capable to standoff detection of minimal amounts of explosives is laser-based spectroscopy. LDS technique belongs to trace detection, namely to its micro-particles variety. We applied gated Raman and time-resolved luminescence spectroscopy for detection of main explosive materials, both factory and homemade. Raman system was developed and tested by LDS for field remote detection and identification of minimal amounts of explosives on relevant surfaces at a distance of up to 30 meters.

  19. Coherent Structure Dynamics and Turbulent Effects of Horizontal Axis Marine Energy Devices

    NASA Astrophysics Data System (ADS)

    Gajardo, D. I.; Escauriaza, C. R.; Ingram, D.

    2016-12-01

    Harnessing the energy available in the oceans constitutes one of the most promising alternatives for generating clean electricity. There are vast amounts of energy present both in waves and tidal currents so it is anticipated that marine energy will have a major role in non-conventional renewable energy generation in the near to mid future. Nevertheless, before marine hydrokinetic (MHK) devices can be installed in large numbers a better understanding of the physical, social and environmental implications of their operation is needed. This includes understanding the: hydrodynamic processes, interaction with bathymetry, and the local flow characteristics. This study is focused on the effects horizontal axis MHK devices have on flow turbulence and coherent structures. This is especially relevant considering that sites with favourable conditions for MHK devices are tidal channels where a delicate balance exists between the strong tidal currents and the ecosystems. Understanding how MHK devices influence flow conditions, turbulence and energy flux is essential for predicting and assessing the environmental implications of deploying MHK technologies. We couple a Blade Element Momentum Actuator Disk (BEM-AD) model to a Detached Eddy Simulation (DES) flow solver in order to study flow conditions for different configurations of horizontal axis MHK turbines. In this study, we contribute to the understanding of the hydrodynamic behaviour of MHK technologies, and give insights into the effects devices will have on their environment, with emphasis in ambient turbulence and flow characteristics, while keeping in mind that these effects can alter electricity quality and device performance. Work supported by CONICYT grant 80160084, Fondecyt grant 1130940, Chile's Marine Energy Research & Innovation Center (MERIC) CORFO project 14CEI2-28228, and the collaboration between the Pontificia Universidad Católica de Chile and the University of Edinburgh, UK, partially supported by the RC

  20. Effects of Mobile Devices on K-12 Students' Achievement: A Meta-Analysis

    ERIC Educational Resources Information Center

    Tingir, S.; Cavlazoglu, B.; Caliskan, O.; Koklu, O.; Intepe-Tingir, S.

    2017-01-01

    In this meta-analytic study, we investigated the effects of mobile devices on student achievement in science, mathematics and reading in grades K-12. Based on our inclusion criteria, we searched the ERIC and PsycINFO databases and identified 14 peer-reviewed research articles published between 2010 and 2014. We identified the device type, subject…

  1. Rapid identification of ESKAPE bacterial strains using an autonomous microfluidic device.

    PubMed

    Ho, Jack Y; Cira, Nate J; Crooks, John A; Baeza, Josue; Weibel, Douglas B

    2012-01-01

    This article describes Bacteria ID Chips ('BacChips'): an inexpensive, portable, and autonomous microfluidic platform for identifying pathogenic strains of bacteria. BacChips consist of a set of microchambers and channels molded in the elastomeric polymer, poly(dimethylsiloxane) (PDMS). Each microchamber is preloaded with mono-, di-, or trisaccharides and dried. Pressing the layer of PDMS into contact with a glass coverslip forms the device; the footprint of the device in this article is ∼6 cm(2). After assembly, BacChips are degased under large negative pressure and are stored in vacuum-sealed plastic bags. To use the device, the bag is opened, a sample containing bacteria is introduced at the inlet of the device, and the degased PDMS draws the sample into the central channel and chambers. After the liquid at the inlet is consumed, air is drawn into the BacChip via the inlet and provides a physical barrier that separates the liquid samples in adjacent microchambers. A pH indicator is admixed with the samples prior to their loading, enabling the metabolism of the dissolved saccharides in the microchambers to be visualized. Importantly, BacChips operate without external equipment or instruments. By visually detecting the growth of bacteria using ambient light after ∼4 h, we demonstrate that BacChips with ten microchambers containing different saccharides can reproducibly detect the ESKAPE panel of pathogens, including strains of: Enterococcus faecalis, Enteroccocus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Enterobacter aerogenes, and Enterobacter cloacae. This article describes a BacChip for point-of-care detection of ESKAPE pathogens and a starting point for designing multiplexed assays that identify bacterial strains from clinical samples and simultaneously determine their susceptibility to antibiotics.

  2. Rapid Identification of ESKAPE Bacterial Strains Using an Autonomous Microfluidic Device

    PubMed Central

    Ho, Jack Y.; Cira, Nate J.; Crooks, John A.; Baeza, Josue; Weibel, Douglas B.

    2012-01-01

    This article describes Bacteria ID Chips (‘BacChips’): an inexpensive, portable, and autonomous microfluidic platform for identifying pathogenic strains of bacteria. BacChips consist of a set of microchambers and channels molded in the elastomeric polymer, poly(dimethylsiloxane) (PDMS). Each microchamber is preloaded with mono-, di-, or trisaccharides and dried. Pressing the layer of PDMS into contact with a glass coverslip forms the device; the footprint of the device in this article is ∼6 cm2. After assembly, BacChips are degased under large negative pressure and are stored in vacuum-sealed plastic bags. To use the device, the bag is opened, a sample containing bacteria is introduced at the inlet of the device, and the degased PDMS draws the sample into the central channel and chambers. After the liquid at the inlet is consumed, air is drawn into the BacChip via the inlet and provides a physical barrier that separates the liquid samples in adjacent microchambers. A pH indicator is admixed with the samples prior to their loading, enabling the metabolism of the dissolved saccharides in the microchambers to be visualized. Importantly, BacChips operate without external equipment or instruments. By visually detecting the growth of bacteria using ambient light after ∼4 h, we demonstrate that BacChips with ten microchambers containing different saccharides can reproducibly detect the ESKAPE panel of pathogens, including strains of: Enterococcus faecalis, Enteroccocus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Enterobacter aerogenes, and Enterobacter cloacae. This article describes a BacChip for point-of-care detection of ESKAPE pathogens and a starting point for designing multiplexed assays that identify bacterial strains from clinical samples and simultaneously determine their susceptibility to antibiotics. PMID:22848451

  3. Identification of Gustatory–Olfactory Flavor Mixtures: Effects of Linguistic Labeling

    PubMed Central

    2013-01-01

    Two experiments, using different ranges and numbers of stimuli, examined how linguistic labels affect the identification of flavor mixtures containing different proportions of sucrose (gustatory flavorant) and citral (olfactory flavorant). Both experiments asked subjects to identify each stimulus as having either “mostly sugar” or “mostly citrus.” In one condition, no labels preceded the flavor stimuli. In another condition, each flavor stimulus followed a label, either SUGAR or CITRUS, which, the subjects were informed, usually though not always named the stronger flavor component; that is, the labels were probabilistically valid. The results of both experiments showed that the labels systematically modified the identification responses: Subjects responded “sugar” or “citrus” more often when the flavor stimulus followed the corresponding label, SUGAR or CITRUS. But the labels hardly affected overall accuracy of identification. Accuracy was possibly limited, however, by both the confusability of the flavor stimuli per se and the way that confusability could limit the opportunity to discern the probabilistic associations between labels and individual flavor stimuli. We describe the results in terms of a decision-theoretic model, in which labels induce shifts in response criteria governing the identification responses, or possibly effect changes in the sensory representations of the flavorants themselves. PMID:23329730

  4. Application and effectiveness of prophylactic devices in model experiments

    NASA Technical Reports Server (NTRS)

    Kakurin, L. I.

    1977-01-01

    Material is presented for evaluating the effectiveness of prophylactic devices intended for maintaining: a relatively high functional level of the cardiovascular system; the nerve and muscle apparatus; and the water and salt status. The effects of the following are analyzed: physical training, lower body negative pressure, regulation of water and salt consumption, pharmacological preparations, and a combination of these. The author points out the need for further research.

  5. Oral mark in the application of an individual identification: From ashes to truth.

    PubMed

    Chugh, Anshul; Narwal, Anumeha

    2017-01-01

    Forensic odontology is the branch of dentistry which deals with the proper handling, examination, evaluation and presentation of dental findings in the interest of justice. After major disasters and perimortem assaults such as earthquakes, fires, severe head and neck trauma or gross decomposition, accurate and early identification of dead and injured becomes important. In the absence of other records in such cases, identification is based on restorations, missing teeth and prosthetic devices such as partial and complete removable/fixed prosthesis or implant retained devices. This brings out the major role of prosthodontics to investigate the identity of suspects in the criminal cases as well as the deceased human beings in traumatic injuries or in disasters. Denture identification systems are being used as means of postmortem identification of edentulous persons which has evolved from the inclusion of some form of printed label in a denture to more high-tech methods. The provision of implant retained complete lower denture, antemortem, and postmortem radiographs of edentulous persons and correlation of bite marks using special impression techniques provide another potential source of evidence for human identification. Hence, this literature review throws some light on the role played by prosthodontist in forensic odontology.

  6. Effects and Satisfaction of Medical Device Safety Information Reporting System Using Electronic Medical Record.

    PubMed

    Jang, Hye Jung; Choi, Young Deuk; Kim, Nam Hyun

    2017-04-01

    This paper describes an evaluation study on the effectiveness of developing an in-hospital medical device safety information reporting system for managing safety information, including adverse incident data related to medical devices, following the enactment of the Medical Device Act in Korea. Medical device safety information reports were analyzed for 190 cases that took place prior to the application of a medical device safety information reporting system and during a period when the reporting system was used. Also, questionnaires were used to measure the effectiveness of the medical device safety information reporting system. The analysis was based on the questionnaire responses of 15 reporters who submitted reports in both the pre- and post-reporting system periods. Sixty-two reports were submitted in paper form, but after the system was set up, this number more than doubled to 128 reports in electronic form. In terms of itemized reporting, a total of 45 items were reported. Before the system was used, 23 items had been reported, but this increased to 32 items after the system was put to use. All survey variables of satisfaction received a mean of over 3 points, while positive attitude , potential benefits , and positive benefits all exceeded 4 points, each receiving 4.20, 4.20, and 4.13, respectively. Among the variables, time-consuming and decision-making had the lowest mean values, each receiving 3.53. Satisfaction was found to be high for system quality and user satisfaction , but relatively low for time-consuming and decision-making . We were able to verify that effective reporting and monitoring of adverse incidents and the safety of medical devices can be implemented through the establishment of an in-hospital medical device safety information reporting system that can enhance patient safety and medical device risk management.

  7. Effectiveness of Reptile Species Identification--A Comparison of a Dichotomous Key with an Identification Book

    ERIC Educational Resources Information Center

    Randler, Christoph; Zehender, Irene

    2006-01-01

    Species identification tasks are a prerequisite for an understanding of biodiversity. Here, we focused on different educational materials to foster the identification of six European reptile species. Our educational training unit was based on natural plastic models of six species and pupils either used an illustrated identification book or a…

  8. Recent advances in medical device triage technologies for chemical, biological, radiological, and nuclear events.

    PubMed

    Lansdowne, Krystal; Scully, Christopher G; Galeotti, Loriano; Schwartz, Suzanne; Marcozzi, David; Strauss, David G

    2015-06-01

    In 2010, the US Food and Drug Administration (Silver Spring, Maryland USA) created the Medical Countermeasures Initiative with the mission of development and promoting medical countermeasures that would be needed to protect the nation from identified, high-priority chemical, biological, radiological, or nuclear (CBRN) threats and emerging infectious diseases. The aim of this review was to promote regulatory science research of medical devices and to analyze how the devices can be employed in different CBRN scenarios. Triage in CBRN scenarios presents unique challenges for first responders because the effects of CBRN agents and the clinical presentations of casualties at each triage stage can vary. The uniqueness of a CBRN event can render standard patient monitoring medical device and conventional triage algorithms ineffective. Despite the challenges, there have been recent advances in CBRN triage technology that include: novel technologies; mobile medical applications ("medical apps") for CBRN disasters; electronic triage tags, such as eTriage; diagnostic field devices, such as the Joint Biological Agent Identification System; and decision support systems, such as the Chemical Hazards Emergency Medical Management Intelligent Syndromes Tool (CHEMM-IST). Further research and medical device validation can help to advance prehospital triage technology for CBRN events.

  9. Pseudo-Hall Effect in Graphite on Paper Based Four Terminal Devices for Stress Sensing Applications

    NASA Astrophysics Data System (ADS)

    Qamar, Afzaal; Sarwar, Tuba; Dinh, Toan; Foisal, A. R. M.; Phan, Hoang-Phuong; Viet Dao, Dzung

    2017-04-01

    A cost effective and easy to fabricate stress sensor based on pseudo-Hall effect in Graphite on Paper (GOP) has been presented in this article. The four terminal devices were developed by pencil drawing with hand on to the paper substrate. The stress was applied to the paper containing four terminal devices with the input current applied at two terminals and the offset voltage observed at other two terminals called pseudo-Hall effect. The GOP stress sensor showed significant response to the applied stress which was smooth and linear. These results showed that the pseudo-Hall effect in GOP based four terminal devices can be used for cost effective, flexible and easy to make stress, strain or force sensors.

  10. 76 FR 50663 - Effective Date of Requirement for Premarket Approval for Three Class III Preamendments Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... completion of a PDP is not filed by the latter of the two dates, and no IDE is in effect, the device is... availability of a preamendments class III devices strategy document. The strategy document set forth FDA's... approved PMA or a declared completed PDP is required to be in effect for any such devices on or before 180...

  11. Eyewitness identification: Bayesian information gain, base-rate effect equivalency curves, and reasonable suspicion.

    PubMed

    Wells, Gary L; Yang, Yueran; Smalarz, Laura

    2015-04-01

    We provide a novel Bayesian treatment of the eyewitness identification problem as it relates to various system variables, such as instruction effects, lineup presentation format, lineup-filler similarity, lineup administrator influence, and show-ups versus lineups. We describe why eyewitness identification is a natural Bayesian problem and how numerous important observations require careful consideration of base rates. Moreover, we argue that the base rate in eyewitness identification should be construed as a system variable (under the control of the justice system). We then use prior-by-posterior curves and information-gain curves to examine data obtained from a large number of published experiments. Next, we show how information-gain curves are moderated by system variables and by witness confidence and we note how information-gain curves reveal that lineups are consistently more proficient at incriminating the guilty than they are at exonerating the innocent. We then introduce a new type of analysis that we developed called base rate effect-equivalency (BREE) curves. BREE curves display how much change in the base rate is required to match the impact of any given system variable. The results indicate that even relatively modest changes to the base rate can have more impact on the reliability of eyewitness identification evidence than do the traditional system variables that have received so much attention in the literature. We note how this Bayesian analysis of eyewitness identification has implications for the question of whether there ought to be a reasonable-suspicion criterion for placing a person into the jeopardy of an identification procedure. (c) 2015 APA, all rights reserved).

  12. Blue light effect on retinal pigment epithelial cells by display devices.

    PubMed

    Moon, Jiyoung; Yun, Jieun; Yoon, Yeo Dae; Park, Sang-Il; Seo, Young-Jun; Park, Won-Sang; Chu, Hye Yong; Park, Keun Hong; Lee, Myung Yeol; Lee, Chang Woo; Oh, Soo Jin; Kwak, Young-Shin; Jang, Young Pyo; Kang, Jong Soon

    2017-05-22

    Blue light has high photochemical energy and induces cell apoptosis in retinal pigment epithelial cells. Due to its phototoxicity, retinal hazard by blue light stimulation has been well demonstrated using high intensity light sources. However, it has not been studied whether blue light in the displays, emitting low intensity light, such as those used in today's smartphones, monitors, and TVs, also causes apoptosis in retinal pigment epithelial cells. We attempted to examine the blue light effect on human adult retinal epithelial cells using display devices with different blue light wavelength ranges, the peaks of which specifically appear at 449 nm, 458 nm, and 470 nm. When blue light was illuminated on A2E-loaded ARPE-19 cells using these displays, the display with a blue light peak at a shorter wavelength resulted in an increased production of reactive oxygen species (ROS). Moreover, the reduction of cell viability and induction of caspase-3/7 activity were more evident in A2E-loaded ARPE-19 cells after illumination by the display with a blue light peak at a shorter wavelength, especially at 449 nm. Additionally, white light was tested to examine the effect of blue light in a mixed color illumination with red and green lights. Consistent with the results obtained using only blue light, white light illuminated by display devices with a blue light peak at a shorter wavelength also triggered increased cell death and apoptosis compared to that illuminated by display devices with a blue light peak at longer wavelength. These results show that even at the low intensity utilized in the display devices, blue light can induce ROS production and apoptosis in retinal cells. Our results also suggest that the blue light hazard of display devices might be highly reduced if the display devices contain less short wavelength blue light.

  13. Effects of electrode modification using calcium on the performance of alternating current field-induced polymer electroluminescent devices

    NASA Astrophysics Data System (ADS)

    Xia, Yingdong; Chen, Yonghua; Smith, Gregory M.; Li, Yuan; Huang, Wenxiao; Carroll, David L.

    2013-06-01

    In this work, the effects of electrode modification by calcium (Ca) on the performance of AC field induced polymer electroluminescence (FIPEL) devices are studied. The FIPEL device with Ca/Al electrode exhibits 550 cd m-2, which is 27.5 times higher than that of the device with only an Al electrode (20 cd m-2). Both holes and electrons are injected from one electrode in our FIPEL device. We found that the electron injection can be significantly enhanced by a Ca modification on the Al electrode without greatly affecting the hole injection. Therefore, the electrons and holes can be effectively recombined in the emissive layer to form more excitons under the AC voltage, leading to effective light emission. The device emitted much brighter light than other AC-based organic EL devices. This result provides an easy and effective way to improve FIPEL performance.

  14. PILA: Sub-Meter Localization Using CSI from Commodity Wi-Fi Devices

    PubMed Central

    Tian, Zengshan; Li, Ze; Zhou, Mu; Jin, Yue; Wu, Zipeng

    2016-01-01

    The aim of this paper is to present a new indoor localization approach by employing the Angle-of-arrival (AOA) and Received Signal Strength (RSS) measurements in Wi-Fi network. To achieve this goal, we first collect the Channel State Information (CSI) by using the commodity Wi-Fi devices with our designed three antennas to estimate the AOA of Wi-Fi signal. Second, we propose a direct path identification algorithm to obtain the direct signal path for the sake of reducing the interference of multipath effect on the AOA estimation. Third, we construct a new objective function to solve the localization problem by integrating the AOA and RSS information. Although the localization problem is non-convex, we use the Second-order Cone Programming (SOCP) relaxation approach to transform it into a convex problem. Finally, the effectiveness of our approach is verified based on the prototype implementation by using the commodity Wi-Fi devices. The experimental results show that our approach can achieve the median error 0.7 m in the actual indoor environment. PMID:27735879

  15. PILA: Sub-Meter Localization Using CSI from Commodity Wi-Fi Devices.

    PubMed

    Tian, Zengshan; Li, Ze; Zhou, Mu; Jin, Yue; Wu, Zipeng

    2016-10-10

    The aim of this paper is to present a new indoor localization approach by employing the Angle-of-arrival (AOA) and Received Signal Strength (RSS) measurements in Wi-Fi network. To achieve this goal, we first collect the Channel State Information (CSI) by using the commodity Wi-Fi devices with our designed three antennas to estimate the AOA of Wi-Fi signal. Second, we propose a direct path identification algorithm to obtain the direct signal path for the sake of reducing the interference of multipath effect on the AOA estimation. Third, we construct a new objective function to solve the localization problem by integrating the AOA and RSS information. Although the localization problem is non-convex, we use the Second-order Cone Programming (SOCP) relaxation approach to transform it into a convex problem. Finally, the effectiveness of our approach is verified based on the prototype implementation by using the commodity Wi-Fi devices. The experimental results show that our approach can achieve the median error 0.7 m in the actual indoor environment.

  16. Effect of stacking order on device performance of bilayer black phosphorene-field-effect transistor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukhopadhyay, A., E-mail: arnabm.electinstru@gmail.com; Banerjee, L.; Sengupta, A.

    We investigate the effect of stacking order of bilayer black phosphorene on the device properties of p-MOSFET and n-MOSFET. Two layers of black phosphorus are stacked in three different orders and are used as channel material in both n-MOSFET and p-MOSFET devices. The effects of different stacking orders on electron and hole effective masses and output characteristics of MOSFETs, such as ON currents, ON/OFF ratio, and transconductance are analyzed. Our results show that about 1.37 times and 1.49 times increase in ON current is possible along armchair and zigzag directions, respectively, 55.11% variation in transconductance is possible along armchair direction,more » by changing stacking orders (AA, AB, and AC) and about 8 times increase in ON current is achievable by changing channel orientation (armchair or zigzag) in p-MOSFET. About 14.8 mV/V drain induced barrier lowering is observed for both p-MOSFET and n-MOSFET, which signifies good immunity to short channel effects.« less

  17. Analysis of Hanle-effect signals observed in Si-channel spin accumulation devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamura, Yota, E-mail: takamura@spin.pe.titech.ac.jp; Department of Physical Electronics, Tokyo Institute of Technology, 2-12-1, Ookayama, Meguro-ku, Tokyo 152-8552; Akushichi, Taiju

    2014-05-07

    We reexamined curve-fitting analysis for spin-accumulation signals observed in Si-channel spin-accumulation devices, employing widely-used Lorentz functions and a new formula developed from the spin diffusion equation. A Si-channel spin-accumulation device with a high quality ferromagnetic spin injector was fabricated, and its observed spin-accumulation signals were verified. Experimentally obtained Hanle-effect signals for spin accumulation were not able to be fitted by a single Lorentz function and were reproduced by the newly developed formula. Our developed formula can represent spin-accumulation signals and thus analyze Hanle-effect signals.

  18. ESwab as an Optional Collection Device for Use with the Affirm VPIII Microbial Test System

    PubMed Central

    Rivers, C. A.; Lee, J. Y.; Sharples, N.; Ledeboer, N. A.

    2014-01-01

    The ESwab collection device was compared to the collection swab provided as part of the Affirm VPIII microbial identification test kit for testing vaginal specimens with the Affirm test system. There was excellent agreement between the two sampling devices for Candida spp., Gardnerella vaginalis, and Trichomonas vaginalis. PMID:24523475

  19. SIR rumor spreading model considering the effect of difference in nodes’ identification capabilities

    NASA Astrophysics Data System (ADS)

    Wang, Ya-Qi; Wang, Jing

    In this paper, we study the effect of difference in network nodes’ identification capabilities on rumor propagation. A novel susceptible-infected-removed (SIR) model is proposed, based on the mean-field theory, to investigate the dynamical behaviors of such model on homogeneous networks and inhomogeneous networks, respectively. Theoretical analysis and simulation results demonstrate that when we consider the influence of difference in nodes’ identification capabilities, the critical thresholds obviously increase, but the final rumor sizes are apparently reduced. We also find that the difference in nodes’ identification capabilities prolongs the time of rumor propagation reaching a steady state, and decreases the number of nodes that finally accept rumors. Additionally, under the influence of difference of nodes’ identification capabilities, compared with the homogeneous networks, the rumor transmission rate on the inhomogeneous networks is relatively large.

  20. EXOS research on master controllers for robotic devices

    NASA Technical Reports Server (NTRS)

    Marcus, Beth A.; An, Ben; Eberman, Brian

    1992-01-01

    Two projects are currently being conducted by EXOS under the Small Business Innovation Research (SBIR) program with NASA. One project will develop a force feedback device for controlling robot hands, the other will develop an elbow and shoulder exoskeleton which can be integrated with other EXOS devices to provide whole robot arm and hand control. Aspects covered are the project objectives, important research issues which have arisen during the developments, and interim results of the projects. The Phase 1 projects currently underway will result in hardware prototypes and identification of research issues required for complete system development and/or integration.

  1. Supporting child witnesses during identification lineups: Exploring the effectiveness of registered intermediaries

    PubMed Central

    Crane, Laura; Hobson, Zoe; Nash, Gilly; Kirke‐Smith, Mimi; Henry, Lucy A.

    2018-01-01

    Summary Performance at identification lineup was assessed in eighty‐five 6‐ to 11‐year‐old typically developing children. Children viewed a live staged event involving 2 male actors, and were asked to identify the perpetrators from 2 separate lineups (one perpetrator‐present lineup and one perpetrator‐absent lineup). Half the children took part in lineups adapted by a registered intermediary (an impartial, trained professional who facilitates understanding and communication between vulnerable witnesses and members of the justice system), and half took part in “best‐practice” lineups, according to the current guidance for eyewitness identification in England and Wales. Children receiving assistance from a registered intermediary (relative to children who received best‐practice lineups) were more accurate in their identifications for perpetrator‐present lineups, and there was some evidence that they were also more accurate for perpetrator‐absent lineups. This provides the first empirical evidence for the effectiveness of registered intermediary support during identification lineups. PMID:29861545

  2. Supporting child witnesses during identification lineups: Exploring the effectiveness of registered intermediaries.

    PubMed

    Wilcock, Rachel; Crane, Laura; Hobson, Zoe; Nash, Gilly; Kirke-Smith, Mimi; Henry, Lucy A

    2018-01-01

    Performance at identification lineup was assessed in eighty-five 6- to 11-year-old typically developing children. Children viewed a live staged event involving 2 male actors, and were asked to identify the perpetrators from 2 separate lineups (one perpetrator-present lineup and one perpetrator-absent lineup). Half the children took part in lineups adapted by a registered intermediary (an impartial, trained professional who facilitates understanding and communication between vulnerable witnesses and members of the justice system), and half took part in "best-practice" lineups, according to the current guidance for eyewitness identification in England and Wales. Children receiving assistance from a registered intermediary (relative to children who received best-practice lineups) were more accurate in their identifications for perpetrator-present lineups, and there was some evidence that they were also more accurate for perpetrator-absent lineups. This provides the first empirical evidence for the effectiveness of registered intermediary support during identification lineups.

  3. Training the elderly in pedestrian safety: Transfer effect between two virtual reality simulation devices.

    PubMed

    Maillot, Pauline; Dommes, Aurélie; Dang, Nguyen-Thong; Vienne, Fabrice

    2017-02-01

    A virtual-reality training program has been developed to help older pedestrians make safer street-crossing decisions in two-way traffic situations. The aim was to develop a small-scale affordable and transportable simulation device that allowed transferring effects to a full-scale device involving actual walking. 20 younger adults and 40 older participants first participated in a pre-test phase to assess their street crossings using both full-scale and small-scale simulation devices. Then, a trained older group (20 participants) completed two 1.5-h training sessions with the small-scale device, whereas an older control group received no training (19 participants). Thereafter, the 39 older trained and untrained participants took part in a 1.5-h post-test phase again with both devices. Pre-test phase results suggested significant differences between both devices in the group of older participants only. Unlike younger participants, older participants accepted more often to cross and had more collisions on the small-scale simulation device than on the full-scale one. Post-test phase results showed that training older participants on the small-scale device allowed a significant global decrease in the percentage of accepted crossings and collisions on both simulation devices. But specific improvements regarding the way participants took into account the speed of approaching cars and vehicles in the far lane were notable only on the full-scale simulation device. The findings suggest that the small-scale simulation device triggers a greater number of unsafe decisions compared to a full-scale one that allows actual crossings. But findings reveal that such a small-scale simulation device could be a good means to improve the safety of street-crossing decisions and behaviors among older pedestrians, suggesting a transfer of learning effect between the two simulation devices, from training people with a miniature device to measuring their specific progress with a full-scale one

  4. 49 CFR 395.15 - Automatic on-board recording devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... information concerning on-board system sensor failures and identification of edited data. Such support systems... driving today; (iv) Total hours on duty for the 7 consecutive day period, including today; (v) Total hours...-driver operation; (7) The on-board recording device/system identifies sensor failures and edited data...

  5. Extracting forensic evidence from biometric devices

    NASA Astrophysics Data System (ADS)

    Geradts, Zeno J.; Ruifrok, Arnout C.

    2003-08-01

    Over the past few years, both large multinationals and governments have begun to contribute to even larger projects on biometric devices. Terrorist attacks in America and in other countries have highlighted the need for better identification systems for people as well as improved systems for controlling access to buildings. Another reason for investment in Research and Development in Biometric Devices, is the massive growth in internet-based systems -- whether for e-commerce, e-government or internal processes within organizations. The interface between the system and the user is routinely abused, as people have to remember many complex passwords and handle tokens of various types. In this paper an overview is given of the information that is important to know before an examination of such is systems can be done in a forensic proper way. In forensic evidence with biometric devices the forensic examiner should consider the possibilities of tampering with the biometric systems or the possibilities of unauthorized access before drawing conclusions.

  6. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  7. Multiscale Thermo-Mechanical Design and Analysis of High Frequency and High Power Vacuum Electron Devices

    NASA Astrophysics Data System (ADS)

    Gamzina, Diana

    Diana Gamzina March 2016 Mechanical and Aerospace Engineering Multiscale Thermo-Mechanical Design and Analysis of High Frequency and High Power Vacuum Electron Devices Abstract A methodology for performing thermo-mechanical design and analysis of high frequency and high average power vacuum electron devices is presented. This methodology results in a "first-pass" engineering design directly ready for manufacturing. The methodology includes establishment of thermal and mechanical boundary conditions, evaluation of convective film heat transfer coefficients, identification of material options, evaluation of temperature and stress field distributions, assessment of microscale effects on the stress state of the material, and fatigue analysis. The feature size of vacuum electron devices operating in the high frequency regime of 100 GHz to 1 THz is comparable to the microstructure of the materials employed for their fabrication. As a result, the thermo-mechanical performance of a device is affected by the local material microstructure. Such multiscale effects on the stress state are considered in the range of scales from about 10 microns up to a few millimeters. The design and analysis methodology is demonstrated on three separate microwave devices: a 95 GHz 10 kW cw sheet beam klystron, a 263 GHz 50 W long pulse wide-bandwidth sheet beam travelling wave tube, and a 346 GHz 1 W cw backward wave oscillator.

  8. Radiation effects on MOS devices - dosimetry, annealing, irradiation sequence, and sources

    NASA Technical Reports Server (NTRS)

    Stassinopoulos, E. G.; Brucker, G. J.; Van Gunten, O.; Knudson, A. R.; Jordan, T. M.

    1983-01-01

    This paper reports on some investigations of dosimetry, annealing, irradiation sequences, and radioactive sources, involved in the determination of radiation effects on MOS devices. Results show that agreement in the experimental and theoretical surface to average doses support the use of thermo-luminescent dosimeters (manganese activated calcium fluoride) in specifying the surface dose delivered to thin gate insulators of MOS devices. Annealing measurements indicate the existence of at least two energy levels,,s or a activation energies, for recovery of soft oxide MOS devices after irradiation by electrons, protons, and gammas. Damage sensitivities of MOS devices were found to be independent of combinations and sequences of radiation type or energies. Comparison of various gamma sources indicated a small dependence of damage sensitivity on the Cobalt facility, but a more significant dependence in the case of the Cesium source. These results were attributed to differences in the spectral content of the several sources.

  9. Effectiveness study of UNL's crack routing device (CRD) - phase II.

    DOT National Transportation Integrated Search

    2016-12-31

    This project evaluated the crack routing device (CRD) for effectiveness in improving current crack-cutting : practices and for possible adoption as a standard in the Nebraska Department of Roads (NDOR). To enact these : evaluations of CRD, the resear...

  10. A meta-analysis of the effect of media devices on sleep outcomes

    PubMed Central

    Carter, Ben; Rees, Philippa; Hale, Lauren; Bhattacharjee, Darsharna; Paradkar, Mandar

    2017-01-01

    Importance Sleep is vital to children’s bio-psycho-social development. Inadequate sleep quantity and quality is a public health concern with an array of detrimental health outcomes. Portable mobile and media device have become a ubiquitous part of children’s lives and may impact children’s sleep duration and quality. Objective This systematic review was conducted to examine the effect of portable media devices (e.g. mobile phones, and tablet devices) on sleep outcomes Data Sources A search strategy was developed and searches of the published and grey literature were conducted across 12 databases from January 1st 2011 to June 15th, 2015. No language restriction was applied. Study Selection We included randomized controlled trials; cohort; and cross sectional study designs. Of 467 studies identified, 20 cross-sectional studies were assessed for quality Data Extraction and Synthesis Data extraction and quality assessment was independently carried out by two reviewers and disagreements resolved by a third. Data was pooled in a random-effects meta-analysis, and an individual participant meta-analysis was carried out where possible. Main Outcomes and Measures The primary outcomes were: inadequate sleep quantity; poor sleep quality; and excessive daytime sleepiness, carried out following an a priori protocol. Results Twenty studies were included and quality assessed, involving 125,198 children, 50.1% were male. There was a strong and consistent association between bedtime media device use and: inadequate sleep quantity (OR =2.17; 95%CI 1.42-3.32); poor sleep quality (OR=1.46; 95%CI 1.14-1.88); and excessive daytime sleepiness (OR=2.72; 95%CI 1.32-5.61). Additionally, children who had access to (but did not use) media devices at night were more likely to have inadequate: sleep quantity (OR=1.79; 95%CI 1.39-2.31); sleep quality (OR=1.53; 95%CI 1.11-2.10); and daytime sleepiness (OR=2.27; 95%CI 1.54-3.35). Conclusions and relevance This was the first meta-analysis of

  11. Effects of nanoscale vacuum gap on photon-enhanced thermionic emission devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yuan; Liao, Tianjun; Zhang, Yanchao

    2016-01-28

    A new model of the photon-enhanced thermionic emission (PETE) device with a nanoscale vacuum gap is established by introducing the quantum tunneling effect and the image force correction. Analytic expressions for both the thermionic emission and tunneling currents are derived. The electron concentration and the temperature of the cathode are determined by the particle conservation and energy balance equations. The effects of the operating voltage on the maximum potential barrier, cathode temperature, electron concentration and equilibrium electron concentration of the conduction band, and efficiency of the PETE device are discussed in detail for different given values of the vacuum gapmore » length. The influence of the band gap of the cathode and flux concentration on the efficiency is further analyzed. The maximum efficiency of the PETE and the corresponding optimum values of the band gap and the operating voltage are determined. The results obtained here show that the efficiency of the PETE device can be significantly improved by employing a nanoscale vacuum gap.« less

  12. Effect of oxygen supply on the size of implantable islet-containing encapsulation devices.

    PubMed

    Papas, Klearchos K; Avgoustiniatos, Efstathios S; Suszynski, Thomas M

    2016-03-01

    Beta-cell replacement therapy is a promising approach for the treatment of diabetes but is currently limited by the human islet availability and by the need for systemic immunosuppression. Tissue engineering approaches that will enable the utilization of islets or β-cells from alternative sources (such as porcine islets or human stem cell derived beta cells) and minimize or eliminate the need for immunosuppression have the potential to address these critical limitations. However, tissue engineering approaches are critically hindered by the device size (similar to the size of a large flat screen television) required for efficacy in humans. The primary factor dictating the device size is the oxygen availability to islets to support their viability and function (glucose-stimulated insulin secretion [GSIS]). GSIS is affected (inhibited) at a much higher oxygen partial pressure [pO2] than that of viability (e.g. 10 mmHg as opposed to 0.1 mmHg). Enhanced oxygen supply (higher pO2) than what is available in vivo at transplant sites can have a profound effect on the required device size (potentially reduce it to the size of a postage stamp). This paper summarizes key information on the effect of oxygen on islet viability and function within immunoisolation devices and describes the potential impact of enhanced oxygen supply to devices in vivo on device size reduction.

  13. Scan direction induced charging dynamics and the application for detection of gate to S/D shorts in logic devices

    NASA Astrophysics Data System (ADS)

    Lei, Ming; Tian, Qing; Wu, Kevin; Zhao, Yan

    2016-03-01

    Gate to source/drain (S/D) short is the most common and detrimental failure mechanism for advanced process technology development in Metal-Oxide-Semiconductor-Field-Effect-Transistor (MOSFET) device manufacturing. Especially for sub-1Xnm nodes, MOSFET device is more vulnerable to gate-S/D shorts due to the aggressive scaling. The detection of this kind of electrical short defect is always challenging for in-line electron beam inspection (EBI), especially new shorting mechanisms on atomic scale due to new material/process flow implementation. The second challenge comes from the characterization of the shorts including identification of the exact shorting location. In this paper, we demonstrate unique scan direction induced charging dynamics (SDCD) phenomenon which stems from the transistor level response from EBI scan at post metal contact chemical-mechanical planarization (CMP) layers. We found that SDCD effect is exceptionally useful for gate-S/D short induced voltage contrast (VC) defect detection, especially for identification of shorting locations. The unique SDCD effect signatures of gate-S/D shorts can be used as fingerprint for ground true shorting defect detection. Correlation with other characterization methods on the same defective location from EBI scan shows consistent results from various shorting mechanism. A practical work flow to implement the application of SDCD effect for in-line EBI monitor of critical gate-S/D short defects is also proposed, together with examples of successful application use cases which mostly focus on static random-access memory (SRAM) array regions. Although the capability of gate-S/D short detection as well as expected device response is limited to passing transistors and pull-down transistors due to the design restriction from standard 6-cell SRAM structure, SDCD effect is proven to be very effective for gate-S/D short induced VC defect detection as well as yield learning for advanced technology development.

  14. Effects of a new piezoelectric device on periosteal microcirculation after subperiosteal preparation.

    PubMed

    Stoetzer, Marcus; Felgenträger, Dörthe; Kampmann, Andreas; Schumann, Paul; Rücker, Martin; Gellrich, Nils-Claudius; von See, Constantin

    2014-07-01

    Subperiosteal preparation using a periosteal elevator leads to disturbances of local periosteal microcirculation. Soft-tissue damage can usually be considerably reduced using piezoelectric technology. For this reason, we investigated the effects of a novel piezoelectric device on local periosteal microcirculation and compared this approach with the conventional preparation of the periosteum using a periosteal elevator. A total of 20 Lewis rats were randomly assigned to one of two groups. Subperiosteal preparation was performed using either a piezoelectric device or a periosteal elevator. Intravital microscopy was performed immediately after the procedure as well as three and eight days postoperatively. Statistical analysis of microcirculatory parameters was performed offline using analysis of variance (ANOVA) on ranks (p<0.05). At all time points investigated, intravital microscopy demonstrated significantly higher levels of periosteal perfusion in the group of rats that underwent piezosurgery than in the group of rats that underwent treatment with a periosteal elevator. The use of a piezoelectric device for subperiosteal preparation is associated with better periosteal microcirculation than the use of a conventional periosteal elevator. As a result, piezoelectric devices can be expected to have a positive effect on bone metabolism. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Cost-effective rapid prototyping and assembly of poly(methyl methacrylate) microfluidic devices.

    PubMed

    Matellan, Carlos; Del Río Hernández, Armando E

    2018-05-03

    The difficulty in translating conventional microfluidics from laboratory prototypes to commercial products has shifted research efforts towards thermoplastic materials for their higher translational potential and amenability to industrial manufacturing. Here, we present an accessible method to fabricate and assemble polymethyl methacrylate (PMMA) microfluidic devices in a "mask-less" and cost-effective manner that can be applied to manufacture a wide range of designs due to its versatility. Laser micromachining offers high flexibility in channel dimensions and morphology by controlling the laser properties, while our two-step surface treatment based on exposure to acetone vapour and low-temperature annealing enables improvement of the surface quality without deformation of the device. Finally, we demonstrate a capillarity-driven adhesive delivery bonding method that can produce an effective seal between PMMA devices and a variety of substrates, including glass, silicon and LiNbO 3 . We illustrate the potential of this technique with two microfluidic devices, an H-filter and a droplet generator. The technique proposed here offers a low entry barrier for the rapid prototyping of thermoplastic microfluidics, enabling iterative design for laboratories without access to conventional microfabrication equipment.

  16. Real-time Identification System using Mobile Hand-held Devices: Mobile Biometrics Evaluation Framework

    DTIC Science & Technology

    2014-04-01

    must be done to determine current infrastructure and capabilities so that necessary updates and changes can be addressed up front. Mobile biometric...with existing satellite communications infrastructure . 20 PSTP 03-427BIOM 4 State of Mobile Biometric Device Market 4.1 Fingerprint...is a wireless information system highlighted by Real-time wireless data collection mobile device independence, wireless infrastructure independence

  17. Contrast effects on stop consonant identification.

    PubMed

    Diehl, R L; Elman, J L; McCusker, S B

    1978-11-01

    Changes in the identification of speech sounds following selective adaptation are usually attributed to a reduction in sensitivity of auditory feature detectors. An alternative explanation of these effects is based on the notion of response contrast. In several experiments, subjects identified the initial segment of synthetic consonant-vowel syllables as either the voiced stop [b] or the voiceless stop [ph]. Each test syllable had a value of voice onset time (VOT) that placed it near the English voiced-voiceless boundary. When the test syllables were preceded by a single clear [b] (VOT = -100 msec), subjects tended to identify them as [ph], whereas when they were preceded by an unambiguous [ph] (VOT = 100 msec), the syllables were predominantly labeled [b]. This contrast effect occurred even when the contextual stimuli were velar and the test stimuli were bilabial, which suggests a featural rather than a phonemic basis for the effect. To discount the possibility that these might be instances of single-trial sensory adaptation, we conducted a similar experiment in which the contextual stimuli followed the test items. Reliable contrast effects were still obtained. In view of these results, it appears likely that response contrast accounts for at least some component of the adaptation effects reported in the literature.

  18. Causal Beliefs and Effects upon Mental Illness Identification Among Chinese Immigrant Relatives of Individuals with Psychosis

    PubMed Central

    Wonpat-Borja, Ahtoy J.

    2013-01-01

    Identifying factors that facilitate treatment for psychotic disorders among Chinese-immigrants is crucial due to delayed treatment use. Identifying causal beliefs held by relatives that might predict identification of ‘mental illness’ as opposed to other ‘indigenous labels’ may promote more effective mental health service use. We examine what effects beliefs of ‘physical causes’ and other non-biomedical causal beliefs (‘general social causes’, and ‘indigenous Chinese beliefs’ or culture-specific epistemologies of illness) might have on mental illness identification. Forty-nine relatives of Chinese-immigrant consumers with psychosis were sampled. Higher endorsement of ‘physical causes’ was associated with mental illness labeling. However among the non-biomedical causal beliefs, ‘general social causes’ demonstrated no relationship with mental illness identification, while endorsement of ‘indigenous Chinese beliefs’ showed a negative relationship. Effective treatment- and community-based psychoeducation, in addition to emphasizing biomedical models, might integrate indigenous Chinese epistemologies of illness to facilitate rapid identification of psychotic disorders and promote treatment use. PMID:22075770

  19. Causal Beliefs and Effects upon Mental Illness Identification Among Chinese Immigrant Relatives of Individuals with Psychosis.

    PubMed

    Yang, Lawrence H; Wonpat-Borja, Ahtoy J

    2012-08-01

    Identifying factors that facilitate treatment for psychotic disorders among Chinese-immigrants is crucial due to delayed treatment use. Identifying causal beliefs held by relatives that might predict identification of 'mental illness' as opposed to other 'indigenous labels' may promote more effective mental health service use. We examine what effects beliefs of 'physical causes' and other non-biomedical causal beliefs ('general social causes', and 'indigenous Chinese beliefs' or culture-specific epistemologies of illness) might have on mental illness identification. Forty-nine relatives of Chinese-immigrant consumers with psychosis were sampled. Higher endorsement of 'physical causes' was associated with mental illness labeling. However among the non-biomedical causal beliefs, 'general social causes' demonstrated no relationship with mental illness identification, while endorsement of 'indigenous Chinese beliefs' showed a negative relationship. Effective treatment- and community-based psychoeducation, in addition to emphasizing biomedical models, might integrate indigenous Chinese epistemologies of illness to facilitate rapid identification of psychotic disorders and promote treatment use.

  20. The Kaiser Permanente implant registries: effect on patient safety, quality improvement, cost effectiveness, and research opportunities.

    PubMed

    Paxton, Elizabeth W; Inacio, Maria Cs; Kiley, Mary-Lou

    2012-01-01

    Considering the high cost, volume, and patient safety issues associated with medical devices, monitoring of medical device performance is critical to ensure patient safety and quality of care. The purpose of this article is to describe the Kaiser Permanente (KP) implant registries and to highlight the benefits of these implant registries on patient safety, quality, cost effectiveness, and research. Eight KP implant registries leverage the integrated health care system's administrative databases and electronic health records system. Registry data collected undergo quality control and validation as well as statistical analysis. Patient safety has been enhanced through identification of affected patients during major recalls, identification of risk factors associated with outcomes of interest, development of risk calculators, and surveillance programs for infections and adverse events. Effective quality improvement activities included medical center- and surgeon-specific profiles for use in benchmarking reports, and changes in practice related to registry information output. Among the cost-effectiveness strategies employed were collaborations with sourcing and contracting groups, and assistance in adherence to formulary device guidelines. Research studies using registry data included postoperative complications, resource utilization, infection risk factors, thromboembolic prophylaxis, effects of surgical delay on concurrent injuries, and sports injury patterns. The unique KP implant registries provide important information and affect several areas of our organization, including patient safety, quality improvement, cost-effectiveness, and research.

  1. Effect of Sex Identification on Instrument Assignment by Band Directors

    ERIC Educational Resources Information Center

    Johnson, Christopher M.; Stewart, Erin E.

    2004-01-01

    The purpose of this study was to investigate the effect of sex identification on the assignment of instruments to beginning band students. Participants were band directors solicited at music conferences and music education students solicited from major universities across the United States. Participants completed an online survey about instrument…

  2. Magnetic Penetration Effects in Small Superconducting Devices

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Adams, J. S.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Hsieh, W.-T.; Kelly, D. P.; Nagler, P. C.; Porst, J.-P.; Sadleir, J. E.; hide

    2011-01-01

    The temperature dependent behavior of a superconducting body in an applied magnetic field involves flux penetration/expulsion both from screening currents (within a magnetic penetration depth) and variations in the superconducting order parameter (locally to form vortices or a mixed state, or globally in the Meissner effect). The temperature dependence of the magnetic penetration depth, in particular, has been used to make highly sensitive macroscopic thermometers. For the microscopic device volumes required in sensitive low temperature photon detectors, properties of actual thin film materials, non-uniformity of applied magnetic fields, and the influence of measurement circuit dynamics are complicating factors. We discuss the various penetration effects as demonstrated in a particularly promising combination of material and geometry that we have used to make sensitive x-ray microcalorimeters.

  3. Novel wearable-type biometric devices based on skin tissue optics with multispectral LED-photodiode matrix

    NASA Astrophysics Data System (ADS)

    Jo, Young Chang; Kim, Hae Na; Kang, Jae Hwan; Hong, Hyuck Ki; Choi, Yeon Shik; Jung, Suk Won; Kim, Sung Phil

    2017-04-01

    In this study, we examined the possibility of using a multispectral skin photomatrix (MSP) module as a novel biometric device. The MSP device measures optical patterns of the wrist skin tissue. Optical patterns consist of 2 × 8 photocurrent intensities of photodiode arrays, which are generated by optical transmission and diffuse reflection of photons from LED light sources with variable wavelengths into the wrist skin tissue. Optical patterns detected by the MSP device provide information on both the surface and subsurface characteristics of the human skin tissue. We found that in the 21 subjects we studied, they showed their unique characteristics, as determined using several wavelengths of light. The experimental results show that the best personal identification accuracy can be acquired using a combination of infrared light and yellow light. This novel biometric device, the MSP module, exhibited an excellent false acceptance rate (FAR) of 0.3% and a false rejection rate (FRR) of 0.0%, which are better than those of commercialized biometric devices such as a fingerprint biometric system. From these experimental results, we found that people exhibit unique optical patterns of their inner-wrist skin tissue and this uniqueness could be used for developing novel high-accuracy personal identification devices.

  4. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    PubMed

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  5. WiFi-based person identification

    NASA Astrophysics Data System (ADS)

    Yuan, Jing

    2016-10-01

    There has been increased interest in WIFI devices equipped with multiple antennas, which brings various wireless sensing applications such as localization, gesture identification and motion tracking. WIFI-based sensing has a lot of benefits such as device Free, which has shown great potential in smart scenarios. In this paper, we present WIP, a system that can distinguish a person from a small group of people. We prove that Channel State Information (CSI) can identify a person's gait. From the related-work, different people have different gait features. Thus the CSI-based gait features can be used to identify a person. We then proposed a machine-learning model-ANN to classify different person. The results show that ANN has a good performance in our scenario.

  6. Automatic identification and location technology of glass insulator self-shattering

    NASA Astrophysics Data System (ADS)

    Huang, Xinbo; Zhang, Huiying; Zhang, Ye

    2017-11-01

    The insulator of transmission lines is one of the most important infrastructures, which is vital to ensure the safe operation of transmission lines under complex and harsh operating conditions. The glass insulator often self-shatters but the available identification methods are inefficient and unreliable. Then, an automatic identification and localization technology of self-shattered glass insulators is proposed, which consists of the cameras installed on the tower video monitoring devices or the unmanned aerial vehicles, the 4G/OPGW network, and the monitoring center, where the identification and localization algorithm is embedded into the expert software. First, the images of insulators are captured by cameras, which are processed to identify the region of insulator string by the presented identification algorithm of insulator string. Second, according to the characteristics of the insulator string image, a mathematical model of the insulator string is established to estimate the direction and the length of the sliding blocks. Third, local binary pattern histograms of the template and the sliding block are extracted, by which the self-shattered insulator can be recognized and located. Finally, a series of experiments is fulfilled to verify the effectiveness of the algorithm. For single insulator images, Ac, Pr, and Rc of the algorithm are 94.5%, 92.38%, and 96.78%, respectively. For double insulator images, Ac, Pr, and Rc are 90.00%, 86.36%, and 93.23%, respectively.

  7. Technology-Enhanced Formative Assessment of Plant Identification

    ERIC Educational Resources Information Center

    Conejo, Ricardo; Garcia-Viñas, Juan Ignacio; Gastón, Aitor; Barros, Beatriz

    2016-01-01

    Developing plant identification skills is an important part of the curriculum of any botany course in higher education. Frequent practice with dried and fresh plants is necessary to recognize the diversity of forms, states, and details that a species can present. We have developed a web-based assessment system for mobile devices that is able to…

  8. Rational design of metal-organic electronic devices: A computational perspective

    NASA Astrophysics Data System (ADS)

    Chilukuri, Bhaskar

    Organic and organometallic electronic materials continue to attract considerable attention among researchers due to their cost effectiveness, high flexibility, low temperature processing conditions and the continuous emergence of new semiconducting materials with tailored electronic properties. In addition, organic semiconductors can be used in a variety of important technological devices such as solar cells, field-effect transistors (FETs), flash memory, radio frequency identification (RFID) tags, light emitting diodes (LEDs), etc. However, organic materials have thus far not achieved the reliability and carrier mobility obtainable with inorganic silicon-based devices. Hence, there is a need for finding alternative electronic materials other than organic semiconductors to overcome the problems of inferior stability and performance. In this dissertation, I research the development of new transition metal based electronic materials which due to the presence of metal-metal, metal-pi, and pi-pi interactions may give rise to superior electronic and chemical properties versus their organic counterparts. Specifically, I performed computational modeling studies on platinum based charge transfer complexes and d 10 cyclo-[M(mu-L)]3 trimers (M = Ag, Au and L = monoanionic bidentate bridging (C/N~C/N) ligand). The research done is aimed to guide experimental chemists to make rational choices of metals, ligands, substituents in synthesizing novel organometallic electronic materials. Furthermore, the calculations presented here propose novel ways to tune the geometric, electronic, spectroscopic, and conduction properties in semiconducting materials. In addition to novel material development, electronic device performance can be improved by making a judicious choice of device components. I have studied the interfaces of a p-type metal-organic semiconductor viz cyclo-[Au(mu-Pz)] 3 trimer with metal electrodes at atomic and surface levels. This work was aimed to guide the device

  9. OPTICAL correlation identification technology applied in underwater laser imaging target identification

    NASA Astrophysics Data System (ADS)

    Yao, Guang-tao; Zhang, Xiao-hui; Ge, Wei-long

    2012-01-01

    The underwater laser imaging detection is an effective method of detecting short distance target underwater as an important complement of sonar detection. With the development of underwater laser imaging technology and underwater vehicle technology, the underwater automatic target identification has gotten more and more attention, and is a research difficulty in the area of underwater optical imaging information processing. Today, underwater automatic target identification based on optical imaging is usually realized with the method of digital circuit software programming. The algorithm realization and control of this method is very flexible. However, the optical imaging information is 2D image even 3D image, the amount of imaging processing information is abundant, so the electronic hardware with pure digital algorithm will need long identification time and is hard to meet the demands of real-time identification. If adopt computer parallel processing, the identification speed can be improved, but it will increase complexity, size and power consumption. This paper attempts to apply optical correlation identification technology to realize underwater automatic target identification. The optics correlation identification technology utilizes the Fourier transform characteristic of Fourier lens which can accomplish Fourier transform of image information in the level of nanosecond, and optical space interconnection calculation has the features of parallel, high speed, large capacity and high resolution, combines the flexibility of calculation and control of digital circuit method to realize optoelectronic hybrid identification mode. We reduce theoretical formulation of correlation identification and analyze the principle of optical correlation identification, and write MATLAB simulation program. We adopt single frame image obtained in underwater range gating laser imaging to identify, and through identifying and locating the different positions of target, we can improve

  10. Fabrication of a liquid-gated enzyme field effect device for sensitive glucose detection.

    PubMed

    Fathollahzadeh, M; Hosseini, M; Haghighi, B; Kolahdouz, M; Fathipour, M

    2016-06-14

    This study presents fabrication of a liquid-gated enzyme field effect device and its implementation as a glucose biosensor. The device consisted of four electrodes on a glass substrate with a channel functionalized by carboxylated multi-walled carbon nanotubes-polyaniline nanocomposite (MWCNTCOOH/PAn) and glucose oxidase. The resistance of functionalized channel increased with increasing the concentration of glucose when an electric field was applied to the liquid gate. The most effective and stable performance was obtained at the applied electric field of 100 mV. The device resistance, R, exhibited a linear relationship with the logarithm of glucose concentration in the range between 0.005 and 500 mM glucose. The detection limit (S/N = 3) for glucose was about 0.5 μM. Large effective area and good conductivity properties of MWCNTCOOH/PAn nanocomposite were the key features of the fabricated sensitive and stable glucose biosensor. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Single Event Effect Testing of the Analog Devices ADV212

    NASA Technical Reports Server (NTRS)

    Wilcox, Ted; Campola, Michael; Kadari, Madhu; Nadendla, Seshagiri R.

    2017-01-01

    The Analog Devices ADV212 was initially tested for single event effects (SEE) at the Texas AM University Cyclotron Facility (TAMU) in July of 2013. Testing revealed a sensitivity to device hang-ups classified as single event functional interrupts (SEFI), soft data errors classified as single event upsets (SEU), and, of particular concern, single event latch-ups (SEL). All error types occurred so frequently as to make accurate measurements of the exposure time, and thus total particle fluence, challenging. To mitigate some of the risk posed by single event latch-ups, circuitry was added to the electrical design to detect a high current event and automatically recycle power and reboot the device. An additional heavy-ion test was scheduled to validate the operation of the recovery circuitry and the continuing functionality of the ADV212 after a substantial number of latch-up events. As a secondary goal, more precise data would be gathered by an improved test method, described in this test report.

  12. Effects of surface properties on droplet formation inside a microfluidic device

    NASA Astrophysics Data System (ADS)

    Steinhaus, Ben; Shen, Amy

    2004-11-01

    Micro-fluidic devices offer a unique method of creating and controlling droplets on small length scales. A microfluidic device is used to study the effects of surface properties on droplet formation of a 2-phase flow system. Four phase diagrams are generated to compare the dynamics of the 2 immiscible fluid system (silicone oil and water) inside microchannels with different surface properties. Results show that the channel surface plays an important role in determining the flow patterns and the droplet formation of the 2-phase fluid system.

  13. Tunable nano Peltier cooling device from geometric effects using a single graphene nanoribbon

    NASA Astrophysics Data System (ADS)

    Li, Wan-Ju; Yao, Dao-Xin; Carlson, E. W.

    2014-08-01

    Based on the phenomenon of curvature-induced doping in graphene we propose a class of Peltier cooling devices, produced by geometrical effects, without gating. We show how a graphene nanoribbon laid on an array of curved nano cylinders can be used to create a targeted and tunable cooling device. Using two different approaches, the Nonequilibrium Green's Function (NEGF) method and experimental inputs, we predict that the cooling power of such a device can approach the order of kW/cm2, on par with the best known techniques using standard superlattice structures. The structure proposed here helps pave the way toward designing graphene electronics which use geometry rather than gating to control devices.

  14. Transformational Leadership, Transactional Contingent Reward, and Organizational Identification: The Mediating Effect of Perceived Innovation and Goal Culture Orientations.

    PubMed

    Xenikou, Athena

    2017-01-01

    Purpose: The aim of this research was to investigate the effect of transformational leadership and transactional contingent reward as complementary, but distinct, forms of leadership on facets of organizational identification via the perception of innovation and goal organizational values. Design/Methodology/Approach: Three studies were carried out implementing either a measurement of mediation or experimental-causal-chain design to test for the hypothesized effects. Findings: The measurement of mediation study showed that transformational leadership had a positive direct and indirect effect, via innovation value orientation, on cognitive identification, whereas transactional contingent reward was more strongly related to affective, rather than cognitive, identification, and goal orientation was a mediator of their link. The findings of the two experimental-causal-chain studies further supported the hypothesized effects. Transformational leadership was found to lead subordinates to perceive the culture as more innovative compared to transactional contingent reward, whereas transactional contingent reward led employees to perceive the culture as more goal, than innovation, oriented. Finally, innovation, compared to goal, value orientation increased cognitive identification, while goal orientation facilitated affective, rather than cognitive, identification. Implications: The practical implications involve the development of strategies organizations can apply, such as leadership training programs, to strengthen their ties with their employees, which, in turn, may have a positive impact on in-role, as well as extra-role, behaviors. Originality/Value: The originality of this research concerns the identification of distinct mechanisms explaining the effect of transformational leadership and transactional contingent reward on cognitive and affective identification applying an organizational culture perspective and a combination of measurement and causal mediation designs.

  15. Self Cooling/Heating Devices

    NASA Technical Reports Server (NTRS)

    1992-01-01

    A NASA RTTC assisted International Thermal Packaging (ITP) in the identification of a NASA-developed synthetic polymer that can absorb 1,000 times its weight in water. The desiccant was used in the manufacture of a self-chilling can, a major innovation for packaging food and beverages. The refrigeration device is a small cylinder, fully incorporated into the can. When used in beverage containers, the top of the can is popped, the internal carbonization pressure is relieved, and the self-chilling reaction is induced. Company product line has been expanded to include two related products, and several licensing agreements have been signed.

  16. Effect of HeartMate left ventricular assist device on cardiac autonomic nervous activity.

    PubMed

    Kim, S Y; Montoya, A; Zbilut, J P; Mawulawde, K; Sullivan, H J; Lonchyna, V A; Terrell, M R; Pifarré, R

    1996-02-01

    Clinical performance of a left ventricular assist device is assessed via hemodynamic parameters and end-organ function. This study examined effect of a left ventricular assist device on human neurophysiology. This study evaluated the time course change of cardiac autonomic activity of 3 patients during support with a left ventricular assist device before cardiac transplantation. Cardiac autonomic activity was determined by power spectral analysis of short-term heart rate variability. The heart rate variability before cardiac transplantation was compared with that on the day before left ventricular assist device implantation. The standard deviation of the mean of the R-R intervals of the electrocardiogram, an index of vagal activity, increased to 27 +/- 7 ms from 8 +/- 0.6 ms. The modulus of power spectral components increased. Low frequency (sympathetic activity) and high frequency power (vagal activity) increased by a mean of 9 and 22 times of each baseline value (low frequency power, 5.2 +/- 3.0 ms2; high frequency power, 2.1 +/- 0.7 ms2). The low over high frequency power ratio decreased substantially, indicating an improvement of cardiac sympatho-vagal balance. The study results suggest that left ventricular assist device support before cardiac transplantation may exert a favorable effect on cardiac autonomic control in patients with severe heart failure.

  17. Quantitative modeling of total ionizing dose reliability effects in device silicon dioxide layers

    NASA Astrophysics Data System (ADS)

    Rowsey, Nicole L.

    The electrical breakdown of oxides and oxide/semiconductor interfaces is one of the main reasons for device failure in integrated circuits, especially devices under high-stress conditions. One high-stress environment of interest is the space environment. All electronics are vulnerable to ionizing radiation; any high-energy particle that passes through an insulating layer will deposit unwanted charge there, causing shifts in device characteristics. Designing electronics for use in space can be a challenge, because much more energetic radiation exits in space than on Earth, as there is no atmosphere in space to collide with, and thereby reduce the energy of, energetic particles. Although oxide charging due to ionizing radiation creates well-known changes in device characteristics, or total ionizing dose effects, it is still poorly-understood exactly how these changes come about. There are many theories that draw upon a large body of both experimental work and, more recently, quantum-mechanical first principles calculations at the molecular level. This work uses FLOODS, a 3D object-oriented device simulator with multi-physics capability, to investigate these theories, by simulating oxide degradation in realistic device geometries, and comparing the subsequent degradation in device characteristics to experimental measurements. The charge trapping and defect-modulated transport models developed and implemented here have resulted in the first quantitative account of the enhanced low-dose-rate sensitivity effect, and are applicable in a comprehensive range of hydrogen environments. Measurements show that devices exposed to ionizing radiation at high dose rates exhibit less degradation that those exposed at low dose rates. Furthermore, the observed trend differs depending on the amount of hydrogen available before, during, and after irradiation. It is therefore important to understand and take into account the effects of dose rate and hydrogen when developing accelerated

  18. Irradiate-anneal screening of total dose effects in semiconductor devices

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Price, W. E.

    1976-01-01

    Judicious choice of radiation dose and parameter change acceptance criteria, absence of anomalous anneal phenomena, and absence of anomalous reirradiation effects are recognized as essential for a successful irradiation-anneal (IRAN) screening procedure to ensure that no device will fall, upon reirradiation, above parametric limits assigned for the worst case application. Reirradiation and irradiation-anneal behavior of various semiconductor devices are compared and those that do not lend themselves to IRAN screening are singled out. Information needed to judge the suitability of an IRAN type screening program is detailed. Reasons for success of the limited IRAN screening of flight parts for the Mariner Jupiter/Saturn (MJS '77) spacecraft are indicated.

  19. Appearance-change instruction effects on eyewitness lineup identification accuracy are not moderated by amount of appearance change.

    PubMed

    Molinaro, Peter F; Arndorfer, Andrea; Charman, Steve D

    2013-12-01

    Instructing witnesses that a criminal may have changed appearance prior to showing them a lineup has been shown to increase false identifications without increasing correct identifications (S. D. Charman & G. L. Wells, 2007, Is the appearance-change instruction a good idea? Law and Human Behavior, Vol. 31, pp. 3-22). However, the generalizability of the effects of this appearance-change instruction (ACI) is unknown, and there are reasons to believe that the instruction's effects may be moderated by the amount of appearance change the criminal has actually undergone. The current study tested this hypothesis. Undergraduate students (N = 315) were exposed to a series of target faces and lineups, some of which contained the target and some of which did not, and made identification decisions. Half of the participants received a standard ACI prior to each lineup; the other half did not. The targets varied with respect to the amount to which their appearance had changed. Results indicated that the ACI inflated false identifications without inflating correct identifications, and that these effects did not depend on the amount of appearance change the target had undergone. Current recommendations to administer the ACI seem to be unfounded and may be harmful to the reliability of identification evidence. (c) 2013 APA, all rights reserved

  20. Simplifying Nanowire Hall Effect Characterization by Using a Three-Probe Device Design.

    PubMed

    Hultin, Olof; Otnes, Gaute; Samuelson, Lars; Storm, Kristian

    2017-02-08

    Electrical characterization of nanowires is a time-consuming and challenging task due to the complexity of single nanowire device fabrication and the difficulty in interpreting the measurements. We present a method to measure Hall effect in nanowires using a three-probe device that is simpler to fabricate than previous four-probe nanowire Hall devices and allows characterization of nanowires with smaller diameter. Extraction of charge carrier concentration from the three-probe measurements using an analytical model is discussed and compared to simulations. The validity of the method is experimentally verified by a comparison between results obtained with the three-probe method and results obtained using four-probe nanowire Hall measurements. In addition, a nanowire with a diameter of only 65 nm is characterized to demonstrate the capabilities of the method. The three-probe Hall effect method offers a relatively fast and simple, yet accurate way to quantify the charge carrier concentration in nanowires and has the potential to become a standard characterization technique for nanowires.